6815 SLC Expander

Product Installation Document

12 Clintonville Road, Northford, CT 06472-1610 USA PN LS10173-001SK-E:A 07/01/2017 ECN 16-0218


203-484-7161 • FAX 203-484-7118 •

6815 SLC Expander panel assembly and secure with screws


provided with the 6815.
The 6815 SLC expander lets you add additional –OR–
addressable devices to a compatible Fire Alarm If mounting the 6815 in a 5815RMK or SK-
Control Panels (FACP). NIC-KIT orientate the 6815 board(s) as
shown in Figure 1 and snap into place on the
Installation and wiring of this device must be
plastic standoffs.
done in accordance with NFPA 72 and local
ordinances.

Compatibility

The 6815 is for use with compatible Honeywell


Silent Knight and Farenhyt Series Fire Alarm
Control Panels FACP's:
Note: For compatibility, programming and more information
see FACP installation manual.

Specifications
Standby Current: 78mA
Alarm Current: 78mA
Operating Voltage: 24VDC
Operating Temperature: 32°F to 120°F
(0°C to 49°C) Figure 1: Standoff Installation and 6815 Board
Mounting
Mounting Wiring
You can mount the 6815 in a compatible FACP
See Table 1 and Figure 2 to wire a 6815 to a
cabinet, in the 5895XL or RPS-1000 intelligent
compatible FACP or the 5895XL.
power module cabinet, or in the SK-NIC-KIT
remote mounting kit. Table 1: 6815 to FACP Connections

Warning! 6815 Terminals FACP SBUS Out Terminals


The electronic components on the 6815 and + +
the panel are sensitive to electrostatic – –
discharge. Wear a grounding strap when
A A
handling any of the boards.
B B
To mount the 6815:
1. Remove power from the panel.
2. If mounting the 6815 in an FACP or
5895XL, use the standoffs located under the
Figure 2. 6815 Connection to the Control Panel

Setting DIP Switches

Use the on-board DIP switches to select an ID


number for the 6815. Refer to Figure 3 to see
how to set the DIP switches for the desired ID
number.

Figure 3. Set DIP Switches on the 6815


Once the ID number is set, you must add the
6815 to the system through programming using
JumpStart or by adding it manually.

Farenhyt™ is a trademark, Silent Knight® and Honeywell® are registered trademarks of Honeywell International, Inc.

2 6815 Installation Document — P/N LS10173-001SK-E:A 07/01/2017