Declaration of Conformity: Bently Nevada Inc. 1631 Bently Parkway South Minden, NV 89423 U.S.A
Declaration of Conformity: Bently Nevada Inc. 1631 Bently Parkway South Minden, NV 89423 U.S.A
GE INTERNAL
PROPRIETARY INFORMATION – THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF GENERAL ELECTRIC COMPANY
AND MAY NOT BE USED OR DISCLOSED TO OTHERS, EXCEPT WITH THE WRITTEN PERMISSION OF GENERAL ELECTRIC
COMPANY.
© 2008 GENERAL ELECTRIC COMPANY & BENTLY NEVADA , INC. MINDEN, NEVADA USA
when installed in accordance with the installation instructions in the Installation and Maintenance Manuals.
Equipment
Catalog
Description
Number
149744 Trendmaster DSM
149787-01 DSM SPA Input Card
149776-01 DSM Ethernet Communication Card
149799-01 DSM 4-20 Input Card
149811-01 DSM 24 V XDCR Input Card
149811-02 DSM DIRECT CURRENT CARD
162459-01 Trendmaster Galvanic Isolator (TMGI)
164746-01 Seismic Direct Input
200200 Trendmaster ProTIM-R – DIN Rail mount style
200250 Trendmaster ProTIM-C – Conduit mount style
GE PROPRIETARY
Uncontrolled When Printed or Transmitted Electronically
EC EMC/LVD/ATEX Declaration of No. 283642 Rev E Page 2 of 6
Conformity
Trendmaster Pro® System
EMC
Standards Accredited Test Lab Test Reports Technical File
EN 61000-6-2:2005 TÜV Rheinland TUV01-003 285208
EN61000-6- 12 Commerce Road TUV02-007 285209
4:2007+A1:2011 Newton, CT 06470 TUV04-003
ATEX
DSM 149744
Standards Notified Body Test Report Certificate No.
EN 60079-0 : 2012 SIRA R28186A/00 SIRA 13ATEX4317X
EN 60079-11 : 2012 Rake Lane, Eccleston
EN 60079-15 : 2010 Chester CH4 9JN England
EN 60079-28 : 2007 Registration Number: 0518
TMGI (162459-01)
Standards Notified Body Test Report Certificate No.
EN 60079-0 : 2009 SIRA R52A9063A, SIRA 02 ATEX 2215
EN 50020 :2002 Rake Lane, Eccleston R52V11372A and SIRA 02 ATEX 4216 X
EN 50824 :1999 Chester CH4 9JN England R52V12590A
EN 50021 :1999 Registration Number: 0518
Ta = -20°C to +70°C
EC EMC/LVD/ATEX Declaration of No. 283642 Rev E Page 3 of 6
Conformity
Trendmaster Pro® System
II 3 GD Ex nA IIC T4 Gc
II 1 G Ex ia IIC T4 Ga
II 1 G Ex ia IIC T4 Ga
T4@ -40°C ≤ Ta ≤ +100°C
II 3 G Ex nA II T4 Gc
Entity Parameters
DSM (149744)
Zone 2
Trendmaster Supply: 20-30 Vdc
Co Lo
Uo Io
Module Number (nF) (mH)
(V) (mA)
IIC IIC
149787-01
SPA Line Input Card 15.62 48 200 0.305
149811-02
Constant Current –24V Direct Input Card -24.15 4.305 150 41.8
164746-01
Seismic Input Card 25.2 3.64 150 41.8
• Energy – limited circuits, EEx nL IIC may be connected to energy limited field devices/ apparatus.
• Optical Transmitter circuit, [Ex op is] IIC may be connected to optical cables and devices of category II
1 G.
TMGI (162459-01)
Zone 0/1
Co Lo/Ro
Part Terminal Uo Io Po (μF) (μH/Ω)
Number Connections (V) (mA) (mW)
IIC IIB IIA IIC IIB IIA
EC EMC/LVD/ATEX Declaration of No. 283642 Rev E Page 4 of 6
Conformity
Trendmaster Pro® System
Ui Ii Pi Ci Li
Part Number Signal Description (V) (mA) (mW) (ηF) (mH)
200200, 200250 Power Supply Terminals 15 150 560 0 0
ProTIM-C & ProTIM-R Signal Terminals 12 12 36 0 0
Zone 2
200200, 200250
Un ≤ 15 Vdc
In ≤ 50 mA
EC EMC/LVD/ATEX Declaration of No. 283642 Rev E Page 5 of 6
Conformity
Trendmaster Pro® System
• Trendmaster DSM must be installed in a suitable enclosure with a rating of at least IP54. This
requirement is met for an enclosure of type EEx e or EEx n and rated minimum IP54.
• Ambient temperature of Trendmaster DSM inside the enclosure shall not exceed +70C.
• Field devices connected to the external energy limited circuits have to be coded EEx nL in order to
maintain the EEx nL type of protection for the whole circuit.
• External barriers/devices certified as Ex ia/ib are required for Zone 0/1 interface installations when
connecting to transducers.
• Optical transmitter circuit of 149776-02 is coded [Ex op is IIC] and may be connected to optical
devices or apparatus of category Ex II 1 G.
TMGI (162459-01)
Zone 2
• When installed in a Zone 2 hazardous area, the TMGI shall be installed in an enclosure that ensures
compliance with Category 3 enclosure requirements for explosive gas environments as detailed in EN
50021:1999 clause 24.
• When installed in a Zone 22 hazardous area, the TMGI shall be installed in an enclosure that ensures
compliance with Category 3 enclosure requirements for explosive dust environments as detailed in EN
50281-1-1:1998 clause 6.
Zone 0/1
• Shall only be connected to intrinsically safe certified equipment. This combination must be
compatible as regards intrinsic safety rules (see electrical parameters).
• System is intrinsically safe when connected to MTL-765 and MTL-764 certified barriers.
EC EMC/LVD/ATEX Declaration of No. 283642 Rev E Page 6 of 6
Conformity
Trendmaster Pro® System
• ProTIMs may only be connected to 20015x-type accelerometers (LCIE 98 ATEX 6008 X),
200125 type Thermocouples or RTDs.
• The apparatus has to be installed in such a way that it is protected against mechanical impacts and
frictions.
Zone 2
• Shall be connected to a regulated energy limited power supply rated at 16.2 V; 50 mA.
• ProTIMs may only be connected to 200150-type accelerometers (LCIE 98 ATEX 6008 X), 200125 type
Thermocouples or RTDs.
Signatory
6/7/16