You are on page 1/ 6

BENTLY NEVADA No.

283642 Rev E Page 1 of 6


Declaration of Conformity Cage Code
3WAP1
Name: R. Wilson

EC EMC/LVD/ATEX Declaration of Conformity – Approved: J. Taylor


Trendmaster Pro® System
Revision Name Approved Description
E J. DRAKE T. WOODS MERGED ATEX/LVD/EMC INTO ONE DOC EMC:
500000215630

GE INTERNAL
PROPRIETARY INFORMATION – THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF GENERAL ELECTRIC COMPANY
AND MAY NOT BE USED OR DISCLOSED TO OTHERS, EXCEPT WITH THE WRITTEN PERMISSION OF GENERAL ELECTRIC
COMPANY.
© 2008 GENERAL ELECTRIC COMPANY & BENTLY NEVADA , INC. MINDEN, NEVADA USA

EC Declaration of Conformity – EMC/ATEX


Declaration
We: Bently Nevada Inc.
1631 Bently Parkway South
Minden, NV 89423 U.S.A.
Declare in sole responsibility that the equipment to which this declaration applies; complies with

EMC Directive 2014/30/EU


LV Directive 2014/35/EU
and, where the applicable dash option has been ordered, also complies with

ATEX directive 2014/34/EU

when installed in accordance with the installation instructions in the Installation and Maintenance Manuals.
Equipment
Catalog
Description
Number
149744 Trendmaster DSM
149787-01 DSM SPA Input Card
149776-01 DSM Ethernet Communication Card
149799-01 DSM 4-20 Input Card
149811-01 DSM 24 V XDCR Input Card
149811-02 DSM DIRECT CURRENT CARD
162459-01 Trendmaster Galvanic Isolator (TMGI)
164746-01 Seismic Direct Input
200200 Trendmaster ProTIM-R – DIN Rail mount style
200250 Trendmaster ProTIM-C – Conduit mount style

Environmental and Use Conditions: Industrial Applications

GE PROPRIETARY
Uncontrolled When Printed or Transmitted Electronically
EC EMC/LVD/ATEX Declaration of No. 283642 Rev E Page 2 of 6
Conformity
Trendmaster Pro® System

EMC
Standards Accredited Test Lab Test Reports Technical File
EN 61000-6-2:2005 TÜV Rheinland TUV01-003 285208
EN61000-6- 12 Commerce Road TUV02-007 285209
4:2007+A1:2011 Newton, CT 06470 TUV04-003

Where the applicable dash option has been ordered:

ATEX

DSM 149744
Standards Notified Body Test Report Certificate No.
EN 60079-0 : 2012 SIRA R28186A/00 SIRA 13ATEX4317X
EN 60079-11 : 2012 Rake Lane, Eccleston
EN 60079-15 : 2010 Chester CH4 9JN England
EN 60079-28 : 2007 Registration Number: 0518

TMGI (162459-01)
Standards Notified Body Test Report Certificate No.
EN 60079-0 : 2009 SIRA R52A9063A, SIRA 02 ATEX 2215
EN 50020 :2002 Rake Lane, Eccleston R52V11372A and SIRA 02 ATEX 4216 X
EN 50824 :1999 Chester CH4 9JN England R52V12590A
EN 50021 :1999 Registration Number: 0518

ProTIMS (200200, 200250)


Standards Notified Body Test Report Certificate No.
EN 60079-0:2012 LCIE 120243-640147 LCIE 03 ATEX 6459 X
EN 60079-11: 2012 Avenue du Général Leclerc, 33 LCIE 03 ATEX 6460 X
EN 60079-15: 2010 92266 Fontenay-aux-Roses,
France
Registration Number: 0081

Marking Temperature Ratings


DSM (149744) DSM (149744)

I 3(1) G Ex nA [ic] IIC T4 Gc T4 @ Ta = + 70°C

Ex nA op is [op is T4 Gc] IIC T4 Gc

TMGI (162459-01) TMGI (162459-01)

Ta = -20°C to +70°C
EC EMC/LVD/ATEX Declaration of No. 283642 Rev E Page 3 of 6
Conformity
Trendmaster Pro® System

II (1) GD [Ex ia] IIC Ga

II 3 GD Ex nA IIC T4 Gc

II 1 G Ex ia IIC T4 Ga

ProTIMs (200200, 200250)


ProTIMs (200200, 200250)

II 1 G Ex ia IIC T4 Ga
T4@ -40°C ≤ Ta ≤ +100°C
II 3 G Ex nA II T4 Gc

Entity Parameters
DSM (149744)
Zone 2
Trendmaster Supply: 20-30 Vdc
Co Lo
Uo Io
Module Number (nF) (mH)
(V) (mA)
IIC IIC
149787-01
SPA Line Input Card 15.62 48 200 0.305
149811-02
Constant Current –24V Direct Input Card -24.15 4.305 150 41.8
164746-01
Seismic Input Card 25.2 3.64 150 41.8

• Energy – limited circuits, EEx nL IIC may be connected to energy limited field devices/ apparatus.
• Optical Transmitter circuit, [Ex op is] IIC may be connected to optical cables and devices of category II
1 G.

TMGI (162459-01)
Zone 0/1

Co Lo/Ro
Part Terminal Uo Io Po (μF) (μH/Ω)
Number Connections (V) (mA) (mW)
IIC IIB IIA IIC IIB IIA
EC EMC/LVD/ATEX Declaration of No. 283642 Rev E Page 4 of 6
Conformity
Trendmaster Pro® System

Power terminal 2 with


respect to terminal 3 ±14.34 142 510 0.67 4.18 15.8 70 280 560
(TIM COM)
Signal + (SIG+) terminal
162459-01 5 with respect to ±9.56 9.5 22.5 3.6 26 210 1586 6344 12688
terminal 3 (TIM COM)
Signal – (SIG-) terminal
4 with respect to ±9.56 9.5 22.5 3.6 26 210 1586 6344 12688
terminal 3 (TIM COM)
Co Lo/Ro
Part Terminal Uo Io Po (μF) (μH/Ω)
Number Connections (V) (mA) (mW)
IIC IIB IIA IIC IIB IIA
Combined
162459-01 parameters of
terminals 2, 4 & 5 with 23.9 161 555 0.126 0.94 3.38 21 84 168
respect to terminal 3
(TIM COM)

ProTIMs (200200, 200250)


Zone 0/1

Ui Ii Pi Ci Li
Part Number Signal Description (V) (mA) (mW) (ηF) (mH)
200200, 200250 Power Supply Terminals 15 150 560 0 0
ProTIM-C & ProTIM-R Signal Terminals 12 12 36 0 0

Cable Parameters Max Number


Gas Group
C (µF) L (mH) L/R (µH/Ω) of ProTIMs
IIC 0.09 2 16 32
IIB 0.705 8 64 32
IIA 2.23 16 130 32

Zone 2
200200, 200250
Un ≤ 15 Vdc
In ≤ 50 mA
EC EMC/LVD/ATEX Declaration of No. 283642 Rev E Page 5 of 6
Conformity
Trendmaster Pro® System

ATEX Special Conditions of Safe Use


English
DSM (149744)

Zone 0/1 & 2

• Trendmaster DSM must be installed in a suitable enclosure with a rating of at least IP54. This
requirement is met for an enclosure of type EEx e or EEx n and rated minimum IP54.

• Ambient temperature of Trendmaster DSM inside the enclosure shall not exceed +70C.

• Field devices connected to the external energy limited circuits have to be coded EEx nL in order to
maintain the EEx nL type of protection for the whole circuit.

• External barriers/devices certified as Ex ia/ib are required for Zone 0/1 interface installations when
connecting to transducers.

• Optical transmitter circuit of 149776-02 is coded [Ex op is IIC] and may be connected to optical
devices or apparatus of category Ex II 1 G.

TMGI (162459-01)

Zone 2

• When installed in a Zone 2 hazardous area, the TMGI shall be installed in an enclosure that ensures
compliance with Category 3 enclosure requirements for explosive gas environments as detailed in EN
50021:1999 clause 24.

• When installed in a Zone 22 hazardous area, the TMGI shall be installed in an enclosure that ensures
compliance with Category 3 enclosure requirements for explosive dust environments as detailed in EN
50281-1-1:1998 clause 6.

ProTIMs (200200, 200250)

Zone 0/1

• Shall be installed per drawings 164160 and 162084.

• Shall only be connected to intrinsically safe certified equipment. This combination must be
compatible as regards intrinsic safety rules (see electrical parameters).

• System is intrinsically safe when connected to MTL-765 and MTL-764 certified barriers.
EC EMC/LVD/ATEX Declaration of No. 283642 Rev E Page 6 of 6
Conformity
Trendmaster Pro® System

• ProTIMs may only be connected to 20015x-type accelerometers (LCIE 98 ATEX 6008 X),
200125 type Thermocouples or RTDs.

• Static discharge warning label affixed on model 200200 polyester enclosure.

• The apparatus has to be installed in such a way that it is protected against mechanical impacts and
frictions.

Zone 2

• Shall be installed per drawings 164161 and 162085.

• Shall be connected to a regulated energy limited power supply rated at 16.2 V; 50 mA.

• ProTIMs may only be connected to 200150-type accelerometers (LCIE 98 ATEX 6008 X), 200125 type
Thermocouples or RTDs.

Maximum characteristics of the system:

Gas Group Maximum Cable Number of 200200


Length (m) or 200250 modules
IIC 1000 125
IIB 3599 127
IIA 4876 127

Signatory
6/7/16

Eric Butterfield Date


Executive Engineering Manager
Bently Nevada Inc.
1631 Bently Parkway South
Minden, NV 89423, US