0% found this document useful (0 votes)
99 views138 pages

Electronic Products 2017

This document provides an overview of electronic products for electrical panels produced by Cabur, including power supplies, overcurrent protection devices, EMI filters, and signal conditioners. Cabur has over 65 years of experience developing and manufacturing reliable products for the electro-technical and electronic industries. The document describes Cabur's wide range of single-phase, two-phase, and three-phase power supplies, EMI filters for both single-phase and three-phase applications, and signal conditioners for interfacing different types of sensors and signals with control and monitoring systems.

Uploaded by

roberio Alves
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
99 views138 pages

Electronic Products 2017

This document provides an overview of electronic products for electrical panels produced by Cabur, including power supplies, overcurrent protection devices, EMI filters, and signal conditioners. Cabur has over 65 years of experience developing and manufacturing reliable products for the electro-technical and electronic industries. The document describes Cabur's wide range of single-phase, two-phase, and three-phase power supplies, EMI filters for both single-phase and three-phase applications, and signal conditioners for interfacing different types of sensors and signals with control and monitoring systems.

Uploaded by

roberio Alves
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 138

Electronic products

for electrical panels


2017/2018 EDITION
Electronic
products
for electrical
panels
2017-2018 Edition

UNI EN-ISO 9001 UNI EN-ISO 14001


WARNING If not specified, the technical data in this catalogue are typical and measured at 25°C (77°F), 230 Vac, Unom, Vdc and rated
current; ripple is measured at 20 MHz with probe connected to 0.1 μF. The technical data in this catalogue are typical and are not binding
for Cabur and may be modified without prior notice, simply for production or improvement and/or evolution reason. Please contact
our technical-commercial offices for any relevant confirmation or updates. For more informations visit our web site www.cabur.eu.

2
since 1952
The Company
F ounded in 1952, Cabur quickly gained the lead position among national manufacturers of terminal blocks for electrical panels, pursuing
a policy which focused particularly on installers' needs and offering cutting-edge technological solutions.

With over 65 years of experience, Cabur develops and creates, based on its own designs, a vast array of products for the electro-technical
and electronic industries famous for their reliability even under extreme conditions.

Our current production includes:

• terminal blocks and boards for electrical panels In pursuing a corporate culture based on Total Quality, Cabur has
• electronic products for electrical panels adopted the main European directives of the reference market,
• terminal blocks for civil and industrial installations and collaborates with the most prestigious national and foreign
• products for photovoltaic systems Institutes and Laboratories.
• industrial marking systems

which perfectly meet the various and complex installation needs


of users.

Our production, which is wide and diversified, represents the


optimal synthesis of Cabur’s long experience as a supplier to R.I.NA.

the main national energy boards and companies, together with


activities and collaboration abroad.

ELECTRONIC PRODUCTS
FOR ELECTRICAL PANELS

PRODUCTS INDUSTRIAL
FOR INSTALLATION MARKING SYSTEMS

PRODUCTS AND SYSTEMS PHOTOVOLTAIC


FOR THE CONNECTION OF SYSTEMS
ELECTRICAL PANELS CONNECTION AND PROTECTION

www.cabur.eu
3
Introduction
Cabur . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 3

Power supplies
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 6
Quick selection table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 8
CSD series Domotic Power single-phase modular switching . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 10
CSF series Cool Power single-phase switching . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 15
Single-phase switching in IP65 case . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 21
CSL series Easy Power single-phase switching . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 22
CSW series Universal Power single-, 2- and 3-phase switching . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 27
CSG series Triple Power 3-phase switching . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 32
CSA series DC/DC switching converters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 39
With 24 Vac transformer input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 41
DC battery charger-UPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 43
CSC series power supply with integrated battery charger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 47
Redundant connection accessory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 48
Engine braking control module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 50

Overcurrent protection devices


Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 52
Electronic programmable overcurrent protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 53

EMI filters
Quick selection table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 54
TDV series 3-phase filter without neutral . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 55
TDS series 3-phase filter without neutral . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 56
TDDS series 3-phase filter without neutral . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 57
TDSS series 3-phase filter without neutral . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 58
TYT series 3-phase filter with neutral . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 59
TY series compact 3-phase filter with neutral . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 60
DK series single-cell single-phase filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 61
DP series double-cell single-phase filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 62

Signal conditioners
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 63
Quick selection table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 65
Analogue signal converters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 67
Passive galvanic isolators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 73
Monitor module for alanogue signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 74
Universal temperature converters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 75
Monitor module for temperature sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 76
Programmable PT100 converters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 77
Programmable TC J and K converters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 78
Monitor module for current signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 79
Current / analogue signal converters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 80
Frequency / analogue signal converters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 82
Auxiliary power supply for sensors and potentiometers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 83
NPN and PNP signal inverter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 84

4
Electromechanical relay modules
Single relay quick selection table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 85
R series relay modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 86
CM series relay modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 88
CKR series relay modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 93
CWRE series relay modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 95
Multiple relay quick selection table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 96
Multiple relay module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 97
Multiple relay module with test button . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 102
CR and CRE series super compact relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 103

Solid state relay modules


Quick selection table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 106
Single relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 107
CKS series super-compact single relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 110
Single relays with exchange output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 112
Signal opto-isolators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 113
Multiple relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 114

Passive interface modules


Quick selection table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 118
SUB-D / terminal block . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 119
FLAT-cable / terminal block . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 121
CCM series component holders . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 123
CDM series diode holders . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 124
CLT series LED testing module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 126
CLP series lamp testing module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 127

Accessories
Electronic circuit housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 128
Bridges and markings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 130
DIN rail clamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 132
Mounting rails . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 133

Teble of contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 135

5
C abur continues to renew and expand its range of power supplies for use in
industrial automation and control of processes and systems, improving product
performance and technology to meet the needs created by the continuing changes
load, which can go from a few tenths of a ms up to 5s.
With high-power power supplies, which power various loads protected from
overcurrent, the capacity to provide overcurrent is indispensable to guarantee
in applications and regulations. selectivity in protection interventions. This is because it allows the fuse of the
malfunctioning load to be “burned” before the electronic protection of the power
QUALITY AND SAFETY: Cabur was the first Italian company to obtain UL508 supply intervenes, disconnecting the output and hence the entire system.
Industrial Control Equipment certification for industrial automation processes and
Hazardous Location Class 1 Div. 2 for processes in dangerous areas, as well as to ELECTRONIC OVERLOAD POWER SUPPLY PROTECTION CAN BE OBTAINED
have been certified as conforming to the Directives on Electric Safety. It also has USING VARIOUS TECHNIQUES:
been EMC certified by an accredited laboratory. All of these are indispensable for – switch off the output as soon as possible: this is cost effective but doesn’t allow
the CE certified label. for either start up of heavy loads nor for protection selectivity for various loads.
– constant power protection: if the allowed overload is sufficiently high, it is possible
INNOVATION AND RESEARCH: to start up heavy loads. However, if the condition continues, the power supply
• 1997 - Cabur is the first Italian company to produce switching power supplies for will continue to operate in overload and with a high thermal stress level. Hiccup
DIN-rails with 90-264Vac/110-340Vdc universal input. protection: combines the advantages of the techniques described above, while
• 2001 - Cabur is the first Italian company to produce high efficiency power supplies limiting the disadvantages because it allows over +50-100% of the overload for at
with resonant technology (the 20A 3-phase dissipates only 36W compared to over least 5 seconds, and then switches off output for a longer break. In this way, the
75W for our competitors at the time). peak power necessary for heavy load peaks is obtained while component heating
• 2009 – With the new generation of power supplies in the catalogue, Cabur is decreased, as they can cool off during the break. Hiccup protection with high
has further improved performance using “Synchronous Rectifier" technology, overcurrent output, for durations from 200 ms to over 5 sec., has been proven to
which reduces power dissipation and operating temperature to the minimum, an satisfy the new requirements established by the Machinery Directive EN 60204-1.
indispensible factor in minimising the size of the power supplies, which are the
smallest on the market. REAL OPERATING TEMPERATURE: the operating temperature range for all Cabur
The lifespan of a power supply is halved by every +10°C increase in operating models is between –20 and +50°C at full load without derating (see technical data),
temperature. Hence, reducing operating temperature is fundamental to endurance certified in accordance with the rigorous UL508 standard.
and reliability, two objectives that can be achieved only by using circuit technology The project takes into consideration the ambient temperature, allowed overcurrent,
and next generation components. Thanks to this combination, Cabur has achieved and overcurrent duration when determining component size, and is always more than
output of over 94% (the new 20A 3-phase dissipates only 28W, compared to the the 45°C required by the standards for electrical panels. Ambient temperature is a
50-75W in heat dissipation found in other products currently on the market). fundamental reference parameter, because this influences not only performance, but
also component operating temperature and power supply duration.
HIGH OVERLOAD CAPACITY: the new power supplies have an overload capacity of
over +50% for 5 seconds or for several minutes (please see the technical data), while HOLD UP TIME: this is the time in which the power supply output supplies nominal
maintaining stable output voltage even under these conditions. voltage at nominal load. This performance is important because it limits the cases in
which machine/system stoppage can occur due to voltage "holes" in the network.
SYSTEM COMMUNICATIONS: all the CSF, CSG, and CSW Series models are EMC standards establish that Hold Up time must be at least 10ms. For all Cabur
provided with “intelligent” alarm contacts that commutate when the output voltage power supplies, Hold Up time is greater than that required by the official standards,
drops below -10% of the nominal value. This allows the controls to activate which ensures better operational consistency in networks with frequent voltage holes.
automated or emergency procedures to reduce machine stoppage, production
losses, and the risk to safety. MTBF: this figure should be taken with care, because it is the result of theoretical
calculations that are easy to manipulate. For example, if we know that the mortality
TOTAL PROTECTION: all models are provided with output protection against overload rate for 25 year old men is 0.1%/year, the resultant MTBF, calculated in accordance
short circuiting, overtemperature, and overvoltage, both for input and output. Input for with SN29500 – IEC 61709, would be 800 years. Obviously, this result is highly
the 3-phase models includes the Active Surge Suppressor – Inrush Current Limiter, unrealistic. The significant piece of information is the “life expectancy,” which for men
which avoids malfunctioning in the case of overvoltage generated by commutation of averages about 75 years – less spectacular but more realistic. The same reasoning
loads or malfunctions on industrial networks, where the value can reach 3-4 times can be applied to electronic products for which, in accordance with the calculation
the network voltage, with a duration of 1.3ms (Regulation VDE-0160), which can be methods, we can use an MTBF of 750,000 hours (85 years), or a life expectancy of
destructive for the input components. This increases reliability, especially in networks about 70,000 hours (7.9 years, on average). The second estimate is less optimistic,
subject to power surges and power malfunctions. but is without doubt closer to reality. As a consequence, data published regarding
MTBF must be interpreted based on the credibility of the calculation methods used.
SHORT CIRCUIT AND OVERLOAD PROTECTION: this serves to protect the power In addition to the values according to SN 29500, Cabur has also chosen to declare
supply from malfunctions due to overloading and overheating of the components. those according to the MIL HDBKn217F standards, which are much stricter.
This function can be designed by starting with different application needs, with
varying practical results and costs. In automated applications, the operating CUSTOM POWER SUPPLIES: Cabur designs and produces “custom” power supplies
conditions and the nature of the loads can vary greatly and are only partially known to on request to meet the requirements of regulations and the high demanding
the power supply designer. Power supplies for automated processes need to meet a applications. Furthermore our laboratory offers technical documentation and the
number of requirements: they need to be protected from overcurrent, but at the same measures which prove the conformity of the products with the directives on Electric
time they need to be able to supply loads which call for a high peak current, working Safety and Electromagnetic Compatibility, besides the necessary technical support
at temperatures of at least 45° C, according to regulations, and sometimes higher, in to define the product characteristics on the basis of the client’s needs and our own
critical ventilation situations and guaranteeing high reliability and acceptable costs. experience.
The overcurrent protection must support the high peak currents required by
loads such as filament lamps (cold, they make a short circuit), capacitive loads THE ENVIRONMENT AND ROHS CONFORMANCE:
such as dc/dc converters and filter condensators (when these switch on they are Cabur was one of the first Italian companies to obtain the International Environmental
seen as a short-circuit for a few tenths of a ms) or inductive loads (engines in Certificate UNI EN ISO 14001, certified by CSQ for ecologically compatible treatment
dc, electromagnets, etc.) which at peak require currents from 5 – 30 times their of all the materials used in our production.
nominal power. Frequently, all these loads must be started up at the same time. The Since 2007, all Cabur products have been manufactured in conformity with the Rohs
breakaway starting current must be provided for a sufficient duration to “start” the Wee directives.
6
L AC + +
General notes GND

PARALLEL AND REDUNDANT PARALLEL CONNECTION: all Cabur power supplies N AC – –


can be connected in parallel to combine the power of two or more power supplies.
In addition, models that already include an output separation diode (ORing diode) are AC +
available for use with redundant parallels (please see the related item in the catalogue).
GND
We recommend adjusting the outputs of all the power supply units to the same voltage AC – Figure 1
(tolerance ± 50 mV), applying the same calibration load, before connecting them in
parallel. We also recommend using power supply units of the same model.
If it is necessary to connect two power supplies without internal diodes in redundant
parallel, the connection must be completed as in fig. 1.

CONNECTION IN SERIES: all Cabur power supplies can have their outputs connected
in series to double the voltage (see fig. 2) or to obtain dual voltage output, for example L AC + +
with ± 12V or ±24 V (see fig. 3). GND V
We recommend that you use power supplies of the same model and an anti-parallel
diode, of an appropriate size to resist the maximum current of the power supply. N AC –
V+V
POWER SIGNAL OK: this is found on all CSF, CSG, and CWS models. The 1A / 30Vdc AC +
contact commutates when output voltage falls below the threshold of -10% of nominal
voltage, in the case of a short circuit on the output line or an overload that exceeds the GND V
specifications, or due to network failure. Figure 2
AC – –
100-340Vdc POWER SUPPLY: available for certain models (please see technical data),
which respect the following:
– power supply of 110…127 Vdc, reduces output current by 25%
– min. voltage allowed 100 Vdc, max 340 for single phase, 280…775 Vdc for single/2-
phase, 564… 775Vdc for 3-phase (please see technical data) L AC + +
– respect input polarity as indicated in the instructions.
GND V
+V
N AC –
Note for power supplies with secondary input from a 0
transformer
AC +
-V
ISOLATION: this series of power supply units is not insulated. GND V
TYPE OF USE: they are suitable for use in PELV (Protective Extra Low Voltage, one pole
grounded) and SELV (Safety Extra Low Voltage, no pole grounded). AC – – Figure 3
The transformer used must have double or reinforced isolation in accordance with CEI
14.6 / EN 60742.
In the case of use in PELV circuits, only ground one pole of the 24 Vdc of the power
supply unit. In the case of use in SELV circuits, do not ground the input grounding
terminal.
24 Vdc
Grounding one pole of the secondary of the transformer and the 24Vdc of the load
power supply would damage the power supply.
24 Vac / 24 Vdc not insulated
power supply

24 Vdc
load

230 Vac / 24 Vac Transformer

Figure 4

230 Vac / 24 Vdc power supply

230 Vac / 24 Vac Transformer

Figure 5

7
These tables are used for quickly identifying items and verifying whether all of the product’s technical details satisfy the set requirements.

Single-phase switching power supply - Cool Power Series


Output voltage Output current Input voltage Notes Type Cat. No. Page
12…15 Vdc 6A 90…264 Vac / 100...345 Vdc (1) (7) (8) (9) CSF85B XCSF85B 17
24 Vdc 1.2 A 90…264 Vac / 100...320 Vdc (1) (9) CSF30C XCSF30C 16
24 Vdc 3.5 A 90…264 Vac / 100...345 Vdc (1) (7) (9) CSF85C XCSF85C 17
24 Vdc 3.5 A 90…264 Vac / 100...345 Vdc (1) (6) (7) (9) CSF85CP XCSF85CP 17
24 Vdc 5A 90…264 Vac / 100...345 Vdc (1) (7) (9) CSF120C XCSF120C 18
24 Vdc 5A 90…264 Vac / 100...345 Vdc (1) (6) (7) (9) CSF120CP XCSF120CP 18
24 Vdc 10 A 120 Vac / 230 Vac (2) (7) CSF240C XCSF240C 19
24 Vdc 10 A 120 Vac / 230 Vac (2) (6) (7) CSF240CP XCSF240CP 19
24 Vdc 20 A 120 Vac / 230 Vac (2) (6) (7) CSF500C XCSF500C 20
48 Vdc 2.5 A 90…264 Vac / 100...345 Vdc (1) (6) (7) CSF120DP XCSF120DP 18
48 Vdc 5A 120 Vac / 230 Vac (2) (6) (7) CSF240DP XCSF240DP 19
48 Vdc 10 A 120 Vac / 230 Vac (2) (6) (7) CSF500D XCSF500D 20

Single-phase switching power supply - Easy Power Series


Output voltage Output current Input voltage Notes Type Cat. No. Page
24 Vdc 3.5 A 90…264 Vac (1) CSL85C XCSL85C 23
24 Vdc 5A 90…264 Vac (1) CSL120C XCSL120C 24
24 Vdc 10 A 120 Vac / 230 Vac (2) CSL240C XCSL240C 25
24 Vdc 20 A 230 Vac - CSL481C XCSL481C 26

Single-phase switching power supply - Domotic Power Series


Output voltage Output current Input voltage Notes Type Cat. No. Page
5…15 Vdc 3...1.5 A 90…264 Vac / 100...345 Vdc (1) (8) (9) CSD30E XCSD30E 12
±12…±15 0.6 A 90…264 Vac / 100...345 Vdc (1) (8) (9) CSD30F XCSD30F 12
12 Vdc 1.2 A 90…264 Vac / 100...315 Vdc (1) (9) CSD15B XCSD15B 11
12…15 Vdc 3.5…3 A 90…264 Vac / 100...345 Vdc (1) (8) (9) CSD50B XCSD50B 13
24 Vdc 0.6 A 90…264 Vac / 100...315 Vdc (1) (9) CSD15C XCSD15C 11
24 Vdc 1.2 A 90…264 Vac / 100...345 Vdc (1) (9) CSD30C XCSD30C 12
24 Vdc 3A 90…264 Vac / 100...345 Vdc (1) (9) CSD70C XCSD70C 14

Single-phase, 2-phase, 3-phase switching power supply - Universal Power Series


Output voltage Output current Input voltage Notes Type Cat. No. Page
12…15 Vdc 8…7 A 1-2x 230-400-500 Vac (1) (3) (7) (8) (9) CSW121B XCSW121B 28
12…15 Vdc 16…15 A 1-2-3x 230-400-500 Vac (1) (3) (4) (7) (8) (9) CSW241B XCSW241B 29
24 Vdc 5A 1-2x 230-400-500 Vac (1) (3) (7) (9) CSW121C XCSW121C 28
24 Vdc 10 A 1-2-3x 230-400-500 Vac (1) (3) (4) (7) (9) CSW241C XCSW241C 29
24 Vdc 20 A 1-2-3x 230-400-500 Vac (1) (3) (4) (7) (9) CSW481C XCSW481C 30
24 Vdc 40 A 1-2x 230-400-500 Vac (3) (6) (7) CSW960CP XCSW960CP 31
48 Vdc 5A 1-2-3x 230-400-500 Vac (1) (3) (4) (6) (7) (9) CSW241DP XCSW241DP 29
48 Vdc 10 A 1-2-3x 230-400-500 Vac (1) (3) (4) (7) (9) CSW481D XCSW481D 30
72 Vdc 3.3 A 1-2-3x 230-400-500 Vac (1) (3) (4) (6) (7) (8) (9) CSW241G XCSW241G 29
72 Vdc 6A 1-2-3x 230-400-500 Vac (1) (3) (4) (7) (8) (9) CSW481G XCSW481G 30

8
These tables are used for quickly identifying items and verifying whether all of the product’s technical details satisfy the set requirements.

3-phase switching power supply - Triple Power Series


Output voltage Output current Input voltage Notes Type Cat. No. Page
24 Vdc 20 A 3x 400-500 Vac (4) (7) CSG481C XCSG481C 33
24 Vdc 20 A 3x 400-500 Vac (4) (7) CSG500C XCSG500C 34
24 Vdc 30 A 3x 400-500 Vac (4) (7) CSG720C XCSG720C 35
24 Vdc 40 A 3x 400-500 Vac (4) (7) CSG960C XCSG960C 36
24 Vdc 100 A 3x 400-500 Vac (4) (6) (7) (8) CSG2401C XCSG2401C 37
48 Vdc 15 A 3x 400-500 Vac (4) (6) (7) CSG720D XCSG720D 35
48 Vdc 20 A 3x 400-500 Vac (4) (6) (7) CSG960D XCSG960D 36
48 Vdc 50 A 3x 400-500 Vac (4) (6) (7) (8) CSG2401D XCSG2401D 37
72 Vdc 6.7 A 3x 400-500 Vac (4) (6) (7) (8) CSG500G XCSG500G 34
72 Vdc 13.3 A 3x 400-500 Vac (4) (6) (7) (8) CSG960G XCSG960G 36
72 Vdc 33 A 3x 400-500 Vac (4) (6) (7) (8) CSG2401G XCSG2401G 38
170 Vdc 14 A 3x 400-500 Vac (4) (6) (7) (8) CSG2401R XCSG2401R 38

Switching power supplies in IP65 case


Output voltage Output current Input type Input voltage Notes Type Cat. No. Page
24 Vdc 5A Single phase 90…264 Vac / 100...345 Vdc (1) (7) (9) CSF565 XCSF565 21

Power supply with input from a transformer


Output voltage Output current Input type Input voltage Notes Type Cat. No. Page
1.2…24 Vdc 1.5 A From transformer 9…26 Vac (5) (8) CL1R XCL1R 41
1.2…24 Vdc 5A From transformer 9…26 Vac (5) (8) CL5R XCL5R 41

Filtered power supply with not stabilised output


Output voltage Output current Input type Input voltage Notes Type Cat. No. Page
12…24 Vdc 6A From transformer 9…20 Vac (5) AR6 XAR6 42

DC/DC isolated converters


Input voltage Output voltage Output current Notes Type Cat. No. Page
12 Vdc 24 Vdc 5A (9) CSA120BC XCSA120BC 39
24 Vdc 12…15 Vdc 7A (8) (9) CSA120CB XCSA120CB 39
24 Vdc 24 Vdc 5A (9) CSA120CC XCSA120CC 39
48 Vdc 24 Vdc 5A (9) CSA120DC XCSA120DC 39
110 Vdc 24 Vdc 10 A (6) (7) (9) CSA240FC XCSA240FC 40

(All wide range single-phase power supplies may be powered at 110 Vdc)

Notes (5) secondary input from a transformer


(1) wide range single-phase input (6) redundant version
(2) double range single-phase input (7) with failure contact
(3) 2-phase input (8) with adjustable output
(4) 3-phase input (9) DC/DC converter

9
Modular switching power supply - CSD Series
DOMOTIC POWER
Single-phase switching power supply with power up to 70W for use in civil and industrial
automation applications. The technical and design characteristics of the housing, with standard
modular DIN measurements for installation in control units were planned to optimise use in home
automation. The performance level and compact size also make it an excellent solution for electrical
panels and shallow containers.
High output and a contained working temperature support energy savings and longer component life.
Suggested uses
• Industrial automation applications
• Civil automation applications
• General applications in systems installed using small remote panels

Main features
• The 90…264 Vac and 110…370 Vdc inputs, make it suitable for use on all power supply networks.
• These are Isolation Class 2 power supplies that do not require a grounding connection, which
reduces the times and costs of installation in remote panels and surveillance and monitoring
systems.
• Their high efficiency reduces energy consumption and operating temperature and allows for use in
small housings.
• The large power reserve allows continuous current to be supplied up to at least +50% higher than
the rated value, ensuring safety and reliability.
• Short-circuit and overload protection designed to deliver peak currents more than 150% higher than
the rated value required by heavy loads.
• Thermal protection prevents failure in cases of prolonged overload at high ambient temperatures.
• Thanks to the high performance and excellent ventilation of internal the components, they are
greatly reduced in size and have a degree of protection from accidental contacts of IP20 per IEC529.

Short-circuit and overload protection


Designed to deliver the typical peak
currents required by medium loads
Compact size
Ideal for modular control units
and shallow containers

High efficiency
Designed to save energy and
Power boost reduce operating temperature
The output power
supplied reaches up to
130% of the rated value.

Input 90…264 Vac and 110…370 Vdc


Appropriate for use on all power supply
networks

10
Single-phase switching
power supply 120-230
Vac - output power 15 W
• Single-phase input 90…264 Vac and DC 100…315 Vdc 90
• Short circuit, overload, over temperature, input overvoltage
protection
• Isolation Class 2, does not require grounding connection
• Compact dimensions
62
• Suitable for SELV and PELV circuits
35
E203601

NOTES BLOCK DIAGRAM


The depth measurement includes rail clamp clearance.
(2) Over 45°C apply the following derating:
version C: -0.015 A/°C; version B: -0.03 A/°C.
(3) The current deliverable by the power supply also depends on
the line resistance

VERSIONS Code XCSD15C Code XCSD15B


Output 24 Vdc 0.6 A CSD15C
Output 24 Vdc 0.6 A redundant version –
Output 12 Vdc 1.2 A CSD15B
Output 48 Vdc 0.3 A –
INPUT TECHNICAL DATA
Input rated voltage 120–230 Vac (range 90…264 Vac / 100…315 Vdc)
Frequency 47...63 Hz
Current with nominal lout (Uin 120 / 230 Vac) 0.3 A / 0.16 A ± 10%
Inrush peak current <5A
Power factor > 0.6
Internal protection fuse T 1 A replaceable
External protection on AC line circuit breaker 2 A characteristic C - fuse: T 2 A
OUTPUT TECHNICAL DATA
Output rated voltage 24 Vdc ± 1% 12 Vdc ± 0.5 Vdc
Output adjustable range — —
Continuous current 0.6 A at 50°C (2) 1.2 A at 50°C (2)
Overload limiting current 1.08 A (3) 2.16 A (3)
Short circuit peak current — —
Load regulation < 1% < 1%
Ripple at nominal ratings ≤ 30 mVpp ≤ 30 mVpp
Hold up time (Uin 120 / 230 Vac) >12 ms / >20 ms >12 ms / >20 ms
Overload / short circuit protections hiccup at the overload limit with auto reset/thermal protection
Status display Green LED "DC OK"
Alarm contact threshold – –
Parallel connection possible possible
possible with external ORing possible with external ORing
Redundant parallel connection
diode diode
GENERAL TECHNICAL DATA
Efficiency (Uin 120 / 230 Vac) >85% / >87%
Dissipated power (Uin 120 / 230 Vac) 2.5 W / 2.2 W
Operating temperature range –20...+60°C, with derating above 45°C/thermal protection (2)
Input/output isolation 3 kVac / 60 s SELV output
Input/PE isolation class 2 without PE connection
Output/PE isolation class 2 without PE connection
Safety standards EN 60950-1+A1+A2+A12, UL 508
Electromagnetic compatibility EN61000-6-2, EN61000-6-4
MTBF at 25°C and nominal ratings >750’000 h according to SN 29500 / >250’000 h according to MIL Std. HDBK 217F
Overvoltage category / Pollution degree II / 2
Protection degree IP 20 IEC 529, EN60529
Connection type 2.5 mm2 screw-clamp terminal blocks
Housing material UL94V-0 plastic
Approximate Weight 130 g
Mounting information vertical on rail, allow 10 mm spacing between adjacent components
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 —

11
Single-phase switching
power supply 120-230
Vac - output power 30 W
• Single-phase input 90…264 Vac and DC 100…345 Vdc 90 90
• Short circuit, overload, over temperature, input overvoltage
protection
• Isolation Class 2, does not require grounding connection
• Compact dimensions
• Suitable for SELV and PELV circuits 62 62
71 71
E203601

NOTES BLOCK DIAGRAM


The depth measurement includes rail clamp clearance.
(2) Over 45°C apply the following derating:
versions C and F: -0.03 A/°C; version E: -0.08…-0.04 A/°C.        


(3) The current deliverable by the power supply also depends on





   
the line resistance. 

(4) The current depends on the adjusted output voltage: 3.3A at        


5Vdc, 2A at 9Vdc, 2.2A at 12Vdc, 1.5A at 15Vdc.

 

VERSIONS Code XCSD30C Code XCSD30E Code XCSD30F


Output 24 Vdc 1.2 A CSD30C
Output 24 Vdc 1.2 A redundant version –
Output 5…15 Vdc 3.3…1.5 A CSD30E
Output ±12...±15 Vdc 0.6 A CSD30F
INPUT TECHNICAL DATA
Input rated voltage 120–230 Vac (range 90…264 Vac / 100…345 Vdc)
Frequency 47...63 Hz
Current with nominal lout (Uin 120 / 230 Vac) 0.55 A / 0.28 A ± 10% 0.45 A / 0.25 A ± 10% 0.4 A / 0.2 A ± 10%
Inrush peak current < 13 A < 13 A < 13 A
Power factor > 0.6
Internal protection fuse Replaceable T 2 A
External protection on AC line circuit breaker 3 A characteristic C - fuse: T 3.15 A
OUTPUT TECHNICAL DATA
Output rated voltage 24 Vdc ± 1% 5…15 Vdc ±12...±15 Vdc
Output adjustable range — 5…15 Vdc ±12...±15 Vdc
Continuous current 1.2 A at 50°C (2) 3.3…1.5 A at 50°C (2)(4) 2x0.6 A at 50°C (2)
Overload limiting current 1.6 (3) 4A (3) >2x0.8 A (3)
Short circuit peak current — — —
Load regulation < 1% < 1% < 1%
Ripple at nominal ratings ≤ 50 mVpp ≤ 50 mVpp ≤ 50 mVpp
Hold up time (Uin 120 / 230 Vac) >30 ms / >60 ms >50 ms / >100 ms >50 ms / >100 ms
Overload / short circuit protections hiccup at the overload limit with auto reset/thermal protection
Status display Green LED "DC OK"
Alarm contact threshold – – – –
Parallel connection possible possible possible
possible with external ORing possible with external ORing possible with external ORing
Redundant parallel connection
diode diode diode
GENERAL TECHNICAL DATA
Efficiency (Uin 120 / 230 Vac) >85% / >87% >87% / >89% >87% / >89%
Dissipated power (Uin 120 / 230 Vac) 5.1 W / 4.3 W 4.0 W / 3.4 W 1.6 W / 1.3 W
Operating temperature range –20...+60°C, with derating above 45°C/thermal protection (2)
Input/output isolation 3 kVac / 60 s SELV output
Input/PE isolation class 2 without PE connection
Output/PE isolation class 2 without PE connection
Safety standards EN 60950-1+A1+A2+A12, UL 508
Electromagnetic compatibility EN61000-6-1, EN61000-6-2, EN61000-6-3, EN61000-6-4
MTBF at 25°C and nominal ratings >750'000 h according to SN 29500 / >250'000 h according to MIL Std. HDBK 217F
Overvoltage category / Pollution degree II / 2
Protection degree IP 20 IEC 529, EN60529
Connection type 2.5 mm² fixed screw terminal blocks
Housing material UL94V-0 plastic
Approximate weight 200 g
Mounting information vertical on rail, allow 10 mm spacing between adjacent components
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 —

12
Single-phase switching
power supply 120-230
Vac - output power 50 W
• Single-phase input 90…264 Vac and DC 100…345 Vdc
90
• Short circuit, overload, over temperature, input overvoltage
protection
• Isolation Class 2, does not require grounding connection
• Compact dimensions
• Suitable for SELV and PELV circuits 62
71
E203601

NOTES BLOCK DIAGRAM


The depth measurement includes rail clamp clearance.
(2) With an input powered at 100...127 Vdc, using constant
power and Ta> 45°C, the outrush current is reduced by 25%
(3) Over 45°C apply the following derating:
version C: -0.06 A/°C; version B: -0.085 A/°C.
(4) The value of the current supplied by the power supply also
depends on the line resistance.

VERSIONS Code XCSD50B


Output 24 Vdc 2.2 A –
Output 24 Vdc 2.2 A redundant version
Output 12…15 Vdc 3.5...3 A CSD50B
Output 48 Vdc 1.1 A –
INPUT TECHNICAL DATA
Input rated voltage 120–230 Vac (range 90…264 Vac / 100…345 Vdc) (2)
Frequency 47...63 Hz
Current with nominal lout (Uin 120 / 230 Vac) 0.9 A / 0.5 A ± 10%
Inrush peak current < 15 A
Power factor > 0.6
Internal protection fuse Replaceable T 2 A
External protection on AC line circuit breaker 3 A characteristic C - fuse: T 3.15 A
OUTPUT TECHNICAL DATA
Output rated voltage 12…15 Vdc
Output adjustable range 12…15 Vdc
Continuous current 3.5…3 A at 50°C (3)
Overload limiting current 4.37…3.75 A (4)
Short circuit peak current —
Load regulation < 1%
Ripple at nominal ratings ≤ 50 mVpp
Hold up time (Uin 120 / 230 Vac) >20 ms / >40 ms
Overload / short circuit protections hiccup at the overload limit with auto reset/thermal protection
Status display Green LED "DC OK"
Alarm contact threshold –
Parallel connection possible
Redundant parallel connection possible with external ORing diode
GENERAL TECHNICAL DATA
Efficiency (Uin 120 / 230 Vac) >85% / >88%
Dissipated power (Uin 120 / 230 Vac) 7.9 W / 6.1 W
Operating temperature range –20...+60°C, with derating over 45°C / thermal protection (3)
Input/output isolation 3 kVac / 60 s SELV output
Input/PE isolation class 2 without PE connection
Output/PE isolation class 2 without PE connection
Safety standards EN 60950-1+A1+A2+A12, UL 508
Electromagnetic compatibility EN61000-6-1, EN61000-6-2, EN61000-6-3, EN61000-6-4
MTBF at 25°C and nominal ratings >750'000 h according to SN 29500 / >250'000 h according to MIL Std. HDBK 217F
Overvoltage category / Pollution degree II / 2
Protection degree IP 20 IEC 529, EN60529
Connection type 2.5 mm² fixed screw terminal blocks
Housing material UL94V-0 plastic
Approximate weight 200 g
Mounting information vertical on rail, allow 10 mm spacing between adjacent components
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 —

13
Single-phase switching
power supply 120-230
Vac - output power 70 W
• Single-phase input 90…264 Vac and DC 100…345 Vdc 90
• Short circuit, overload, over temperature, input overvoltage
protection
• Isolation Class 2, does not require grounding connection
• Compact dimensions
• Suitable for SELV and PELV circuits 62
71
E203601

NOTES BLOCK DIAGRAM


The depth measurement includes rail clamp clearance.
(2) With an input powered at 100...127 Vdc, using constant
power and Ta> 45°C, the outrush current is reduced by 25%
(3) O ver 55°C apply the following derating: version C:
-0.15 A/°C.
(4) The value of the current supplied by the power supply also
depends on the line resistance.

VERSIONS Code XCSD70C


Output 24 Vdc 3 A CSD70C
Output 24 Vdc 3 A redundant version –
Output 12…15 Vdc 5…4 A –
Output 48 Vdc 1.5 A –
INPUT TECHNICAL DATA
Input rated voltage 120–230 Vac (range 90…264 Vac / 100…345 Vdc) (2)
Frequency 47...63 Hz
Current with nominal lout (Uin 120 / 230 Vac) 1.25 A / 0.8 A ± 10%
Inrush peak current < 15 A
Power factor > 0.6
Internal protection fuse T 2 A non-replaceable
External protection on AC line circuit breaker 4 A characteristic C - fuse: T 3.15 A
OUTPUT TECHNICAL DATA
Output rated voltage 24 Vdc
Output adjustable range 24...27.5 Vdc
Continuous current 3 A at 55°C (3)
Overload limiting current 4A (4)
Short circuit peak current —
Load regulation < 1%
Ripple at nominal ratings ≤ 60 mVpp
Hold up time (Uin 120 / 230 Vac) >15 ms / >30 ms
Overload / short circuit protections hiccup at the overload limit with auto reset
Status display Green LED "DC OK"
Alarm contact threshold –
Parallel connection possible
possible with external ORing
Redundant parallel connection
diode
GENERAL TECHNICAL DATA
Efficiency (Uin 120 / 230 Vac) >87% / >89%
Dissipated power (Uin 120 / 230 Vac) 10.8 W / 8.9 W
Operating temperature range –20...+60°C, with derating above 55°C (3)
Input/output isolation 3 kVac / 60 s SELV output
Input/PE isolation class 2 without PE connection
Output/PE isolation class 2 without PE connection
Safety standards EN 60950-1+A1+A2+A12, UL 508
Electromagnetic compatibility EN61000-6-1, EN61000-6-2, EN61000-6-3, EN61000-6-4
MTBF at 25°C and nominal ratings >750'000 h according to SN 29500 / >250'000 h according to MIL Std. HDBK 217F
Overvoltage category / Pollution degree II / 2
Protection degree IP 20 IEC 529, EN60529
Connection type 2.5 mm² fixed screw terminal blocks
Housing material UL94V-0 plastic
Approximate weight 250 g
Mounting information vertical on rail, allow 10 mm spacing between adjacent components
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 —

14
COOL POWER
Single-phase switching power supply with DIN-rail, designed specifically for applications in
command and control panels for industrial automation and process control. Capable of delivering +60% Special power supplies for engines DC,
to +80% nominal current for a prolonged period of time while maintaining a constant output voltage and Brushless, and relative drives
equipped with a voltage threshold-controlled failure contact which is triggered when the voltage drops
below 90% of the rated value. With these features and numerous international certifications, New 48Vdc and 72-85Vdc models have been
this range of power supplies enables designers to meet the requirements of the Machinery introduced, designed to reliably power engines
Directive EN 60204-1, allowing the protection devices connected to the output to trigger quickly, safely in DC. They:
• supply peak power equal to even 4-5 times
and selectively, thus ensuring continuity of service to the other parts of the system. the nominal current, which is required by the
engine during the peak phase
Suggested uses • have an output stage protected from
• Applications in industrial automation with high performance and reliability requirements. overvoltage generated by the engines and
• Applications which require selectable overcurrent protections on DC lines drives during braking, which could otherwise
• Applications in machine automation with high command and control voltage reliability and safety cause malfunctions or cause the power supply
requirements to lose control over output voltage stability
• Provide output voltage at 48Vdc, and
• Applications in process control 72…85Vdc. By increasing the voltage of
• Uses with heavy loads the engine power supply, the same power
• Civil automation applications can be obtained at lower current, with
notable advantages for performance, engine
Main features construction, connection wires, and drives.
• The 90…264 Vac and 110…370 Vdc inputs, make it suitable for use on all power supply networks.
• Threshold failure contact which is triggered when the voltage falls below 90% of the rated value.
• Versions with integrated ORing diode for redundant parallel connection, preventing the need for
external devices and reducing bulk and installation costs.
• High efficiency reduces energy consumption and the operating temperature of components and
allows use in small panels and severe environmental conditions.
• Large power reserve allows for delivery of at least +60-80% nominal current and voltage for several
minutes, ensuring safety and reliability.
• Output voltage is adjustable and the output is protected against input surge from the DC line
generated from inductive loads.
• The output is equipped with dual electronic protection which prevents dangerous voltages for
powered components in the event of an internal fault.
• Thermal protection prevents faults in case of prolonged overload with high ambient temperatures.
• Construction ensures excellent ventilation capacity of internal components, with reduced sizes and
a degree of protection from accidental contacts of IP20 per IEC529.
• Thanks to their high performance and excellent ventilation capacity, they are among the smallest on
the market.
Extremely compact dimensions
Among the smallest on the market, Short-circuit and overload protection
optimising the use of space in the panel
without compromising performance Designed to deliver
the strong peak currents
required by heavy loads
Power boost
The output power
reaches 120% of
the nominal value
for several minutes,
up to 160% in the
event of overload, and
up to 300% during
a short-circuit, to
enable the protection
devices connected to
the output to trigger
High efficiency
quickly, safely and
selectively, without Designed to save
the use of additional energy and reduce
modules. operating temperature

Intelligent failure contact


Input 90…264 Vac and 110…370 Vdc Notifies when the output voltage falls below 90%
Appropriate for use on all single-phase of the rated value once a threshold is surpassed
power supply networks
15
Single-phase switching
power supply 120-230
Vac - output power 30 W 82
• Single-phase input 90…264 Vac and DC 100…320 Vdc
• Short circuit, overload and overvoltage protection
• Isolation Class 2, does not require grounding connection
• Compact dimensions
• Suitable for SELV and PELV circuits 99
23
E212719
E203601

NOTES BLOCK DIAGRAM


The depth measurement includes rail clamp clearance.
(1) Version made to order (not kept in stock); contact our sales
office for availability.    

(2) With an input powered at 100...127 Vdc, using constant


 
power and Ta> 45°C, the outrush current is reduced by 25%
(3) O ver 50°C apply the following derating: version C:    
-0.03 A/°C; version B: -0.038 A/°C; version F: -0.013 A/°C
(4) The value of the current supplied by the power supply also
depends on the line resistance.


VERSIONS Code XCSF30C


Output 24 Vdc 1.2 A CSF30C (1)
-
-

INPUT TECHNICAL DATA


Input rated voltage 120–230 Vac (range 90…264 Vac / 100…320 Vdc) (2)
Frequency 47...63 Hz
Current with nominal lout (Uin 120 / 230 Vac) 0.55 A / 0.3 A ± 10% 0.35 A / 0.2 A ± 10%
Inrush peak current < 25 A
Power factor > 0.60
Internal protection fuse Non-replaceable T 1.25 A
External protection on AC line circuit breaker 2 A characteristic C - fuse: T 2 A
OUTPUT TECHNICAL DATA
Output rated voltage 24 Vdc ± 1%
Output adjustable range —
Continuous current 1.2 A at 50°C (3)
Overload limiting current 1.4 A (4)
Short circuit peak current — — —
Load regulation < 1%
Ripple at nominal ratings ≤ 50 mVpp
Hold up time (Uin 120 / 230 Vac) >10 ms / >30 ms
Overload / short circuit protections hiccup at the overload limit with auto reset
Status display Green LED "DC OK"
Alarm contact threshold —
Parallel connection possible
Redundant parallel connection possible with external ORing diode
GENERAL TECHNICAL DATA
Efficiency (Uin 120 / 230 Vac) >86% / >87%
Dissipated power (Uin 120 / 230 Vac) 4.7 W / 4.3 W
Operating temperature range –20...+60°C, with derating over 50°C (3)
Input/output isolation 3 kVac / 60 s SELV output
Input/PE isolation class 2 without PE connection
Output/PE isolation class 2 without PE connection
Safety standards EN 60950-1+A1+A2+A12, UL 508
Electromagnetic compatibility EN61000-6-2, EN61000-6-4
MTBF at 25°C and nominal ratings >750'000 h according to SN 29500 / >250'000 h according to MIL Std. HDBK 217F
Overvoltage category / Pollution degree II / 2
Protection degree IP 20 IEC 529, EN60529
Connection type 2.5 mm² fixed screw terminal blocks
Housing material UL94V-0 plastic
Approximate weight 140 g
Mounting information vertical on rail, allow 10 mm spacing between adjacent components
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 —

16
Single-phase switching
power supply 120-230
Vac - output power 85 W
115
• Single-phase input 90…264 Vac and DC 100…345 Vdc
• Short circuit, overload, over temperature and overvoltage
input and output protection
• Elevated outrush current to ensure the selectivity of
protections and start-up of heavy loads
• Failure contact with threshold Uout -10% 128
• Compact dimensions
• Suitable for SELV and PELV circuits E212719
E203601
39

NOTES BLOCK DIAGRAM


The depth measurement includes rail clamp clearance.
(2) With an input powered at 100...127 Vdc, using constant power
and Ta> 45°C, the outrush current is reduced by 25%
(3) Over 45°C apply the following derating: -0.06 A/°C for version C,
CP and CPH; -0.10 A/°C for version B
(4) For this peak of power, the output voltage does not decrease more
than 10% of the rated value, however the value of the current
supplied by the power supply also depends on the line resistance.

VERSIONS Code XCSF85C Code XCSF85CP Code XCSF85B


Output 24 Vdc 3.5 A CSF85C
Output 24 Vdc 3.5 A redundant version CSF85CP
Output 12…15 Vdc 6 A CSF85B
Output 48 Vdc 1.8 A –
INPUT TECHNICAL DATA
Input rated voltage 120–230 Vac (range 90…264 Vac / 100…345 Vdc) (2)
Frequency 47...63 Hz
Current with nominal lout (Uin 120 / 230 Vac) 1.6 A / 0.9 A ± 10%
Inrush peak current < 20 A
Power factor > 0.65
Internal protection fuse Replaceable T 2 A
External protection on AC line circuit breaker 4 A characteristic C - fuses: T 4 A
OUTPUT TECHNICAL DATA
Output rated voltage 24 Vdc 12…15 Vdc
Output adjustable range 23...27.5 Vdc 12…15 Vdc
Continuous current 3.5 A at 50°C (3) 6 A at 50°C (3)
Overload limiting current 6 A for >30 s 9 A for >30 s
with Uout >90% Un (4) with Uout >90% Un (4)
Short circuit peak current 10 A for 50 ms (4) 10 A for 50 ms (4)
Load regulation < 1% < 1%
Ripple at nominal ratings ≤ 70 mVpp ≤ 30 mVpp
Hold up time (Uin 120 / 230 Vac) >20 ms / >70 ms >15 ms / >60 ms
Overload / short circuit protections hiccup at the overload limit with auto reset/thermal protection
Status display Green LED "DC OK" / failure contact "DC OK" / Red LED "Overload"
Alarm contact threshold 21.6 Vdc 10.8 Vdc
Parallel connection possible possible
possible with external ORing already fitted with internal ORing
Redundant parallel connection possible with external ORing diode
diode diode
GENERAL TECHNICAL DATA
Efficiency (Uin 120 / 230 Vac) >86% / >90% >83% / >87%
Dissipated power (Uin 120 / 230 Vac) 14 W / 10 W 17 W / 13 W
Operating temperature range –20...+60°C, with derating over 45°C / thermal protection (3)
Input/output isolation 3 kVac / 60 s SELV output
Input/PE isolation 1.5 kVac / 60 s
Output/PE isolation 0.5 kVac / 60 s
Safety standards EN 60950-1+A1+A2+A12, UL 508
Electromagnetic compatibility EN61000-6-1, EN61000-6-2, EN61000-6-3, EN61000-6-4
MTBF at 25°C and nominal ratings >500'000 h according to SN 29500 / >150'000 h according to MIL Std. HDBK 217F
Overvoltage category / Pollution degree II / 2
Protection degree IP 20 IEC 529, EN60529
Connection type 2.5 mm² removable screw terminal blocks
Housing material aluminium
Approximate weight 400 g
Mounting information vertical on rail, allow 10 mm spacing between adjacent components
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 —

17
Single-phase switching
power supply 120-230
Vac - output power 120 W
115
• Single-phase input 90…264 Vac and DC 100…345 Vdc
• Short circuit, overload, over temperature and overvoltage
input and output protection
• Elevated outrush current to ensure the selectivity of
protections and start-up of heavy loads
• Failure contact with threshold Uout -10% 128
• Compact dimensions
• Suitable for SELV and PELV circuits E212719
E203601
39

NOTES BLOCK DIAGRAM


The depth measurement includes terminal block and rail clamp clearance.
(2) With an input powered at 100...127 Vdc, using constant power and
Ta> 45°C, the outrush current is reduced by 25%
(3) Over 45°C apply a derating -0.08 A/°C for version C, CP and CPH;
-0.12 A/°C for version B; -0.05 A/°C for version DP;
(4) For this peak of power, the output voltage does not decrease more
than 10% of the rated value, however the value of the current supplied
by the power supply also depends on the line resistance.

VERSIONS Code XCSF120C Code XCSF120CP Code XCSF120DP


Output 24 Vdc 5 A CSF120C
Output 24 Vdc 5 A redundant version CSF120CP
Output 12…15 Vdc 7 A -
Output 48 Vdc 2.5 A redundant version CSF120DP
INPUT TECHNICAL DATA
Input rated voltage 120–230 Vac (range 90…264 Vac / 100…345 Vdc) (2)
Frequency 47...63 Hz
Current with nominal lout (Uin 120 / 230 Vac) 1.9 A / 1.1 A ± 10%
Inrush peak current < 20 A
Power factor > 0.65
Internal protection fuse Replaceable T 3.15 A
External protection on AC line circuit breaker 4 A characteristic C - fuses: T 4 A
OUTPUT TECHNICAL DATA
Output rated voltage 24 Vdc 48 Vdc
Output adjustable range 23...27.5 Vdc 45…55 Vdc
Continuous current 5 A at 45°C (3) 2.5 A at 45°C (3)
Overload limiting current 8 A for >30 s 8 A for >30 s
with Uout >90% Un (4) with Uout >90% Un (4)
Short circuit peak current 15 A for 50 ms (4) 7.5 A for 50 ms (4)
Load regulation < 1% < 1%
Ripple at nominal ratings ≤ 30 mVpp ≤ 30 mVpp
Hold up time (Uin 120 / 230 Vac) >17 ms / >72 ms >16 ms / >81 ms
Overload / short circuit protections hiccup at the overload limit with auto reset/thermal protection
Status display Green LED "DC OK" / failure contact "DC OK" / Red LED "Overload"
Alarm contact threshold <21.6 Vdc <43.2 Vdc
Parallel connection possible possible
possible with external ORing already fitted with internal ORing already fitted with internal ORing
Redundant parallel connection
diode diode diode
GENERAL TECHNICAL DATA
Efficiency (Uin 120 / 230 Vac) >86% / >90% >86% / >90%
Dissipated power (Uin 120 / 230 Vac) 19 W / 13 W 20 W / 13 W
Operating temperature range –20...+60°C, with derating over 45°C / thermal protection (3)
Input/output isolation 3 kVac / 60 s SELV output
Input/PE isolation 1.5 kVac / 60 s
Output/PE isolation 0.5 kVac / 60 s
Safety standards EN 60950-1+A1+A2+A12, UL 508
Electromagnetic compatibility EN61000-6-1, EN61000-6-2, EN61000-6-3, EN61000-6-4
MTBF at 25°C and nominal ratings >500'000 h according to SN 29500 / >150'000 h according to MIL Std. HDBK 217F
Overvoltage category / Pollution degree II / 2
Protection degree IP 20 IEC 529, EN60529
Connection type 2.5 mm² removable screw terminal blocks
Housing material aluminium
Approximate weight 400 g
Mounting information vertical on rail, allow 10 mm spacing between adjacent components
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 —

18
Single-phase switching
power supply 120-230
Vac - output power 240 W
140
• Single-phase input 120 and 230 Vac
• Short circuit, overload, over temperature and overvoltage
input and output protection
• Elevated outrush current to ensure the selectivity of
protections and start-up of heavy loads
• Failure contact with threshold Uout -10% 135
• Compact dimensions
• Suitable for SELV and PELV circuits E212719
E203601
63.5

NOTES BLOCK DIAGRAM


The depth measurement includes terminal block and rail clamp 
clearance.
(2) Double range input with selection via external bridge, direct current    
power supply only between 300 and 345 Vdc  


 
(3) Over 45°C apply the following derating: -0.17 A/°C for version C, 

CP and CPH; -0.27 A/°C for version B; -0.08 A/°C for version DP;    

(4) For this peak of power, the output voltage does not decrease more
than 10% of the rated value, however the value of the current
supplied by the power supply also depends on the line resistance. 

 

  

VERSIONS Code XCSF240C Code XCSF240CP XCSF240DP


Output 24 Vdc 10 A CSF240C
Output 24 Vdc 10 A redundant version CSF240CP
Output 12…15 Vdc 16 A -
Output 48 Vdc 5 A redundant version CSF240DP
INPUT TECHNICAL DATA
Input rated voltage 120 - 230 Vac (range 90…132 Vac / 185…264 Vac / 300...345 Vdc) (2)
Frequency 47...63 Hz
Current with nominal lout (Uin 120 / 230 Vac) 3.5 A / 1.8 A ± 10%
Inrush peak current < 35 A
Power factor > 0.6
Internal protection fuse Replaceable T 6.3 A
External protection on AC line circuit breaker 10 A characteristic C - fuses: T 10 A
OUTPUT TECHNICAL DATA
Output rated voltage 24 Vdc 48 Vdc
Output adjustable range 23...27.5 Vdc 45…55 Vdc
Continuous current 10 A at 45°C (3) 5 A at 45°C (3)
Overload limiting current 15 A for >30 s 7.5 A for >30 s
with Uout >90% Un (4) with Uout >90% Un (4)
Short circuit peak current >25 A for 400 ms (4) >25 A for 400 ms (4)
Load regulation < 1% < 1%
Ripple at nominal ratings ≤ 50 mVpp ≤ 50 mVpp
Hold up time (Uin 120 / 230 Vac) >30 ms / >60 ms >30 ms / >60 ms
Overload / short circuit protections hiccup at the overload limit with auto reset/thermal protection
Status display Green LED "DC OK" / failure contact "DC OK" / Red LED "Overload"
Alarm contact threshold 21.6 Vdc 43.2 Vdc
Parallel connection possible possible
possible with external ORing already fitted with internal ORing already fitted with internal ORing
Redundant parallel connection
diode diode diode
GENERAL TECHNICAL DATA
Efficiency (Uin 120 / 230 Vac) >88% / >90% >89% / >89%
Dissipated power (Uin 120 / 230 Vac) 32 W / 27 W 28 W / 28 W
Operating temperature range –20...+60°C, with derating over 45°C / thermal protection (3)
Input/output isolation 3 kVac / 60 s SELV output
Input/PE isolation 1.5 kVac / 60 s
Output/PE isolation 0.5 kVac / 60 s
Safety standards EN 60950-1+A1+A2+A12, UL 508
Electromagnetic compatibility EN61000-6-1, EN61000-6-2, EN61000-6-3, EN61000-6-4
MTBF at 25°C and nominal ratings >500'000 h according to SN 29500 / >150'000 h according to MIL Std. HDBK 217F
Overvoltage category / Pollution degree II / 2
Protection degree IP 20 IEC 529, EN60529
Connection type 2.5 mm² removable screw terminal blocks
Housing material aluminium
Approximate weight 920 g
Mounting information vertical on rail, allow 10 mm spacing between adjacent components
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 —

19
Single-phase switching
power supply 120-230
Vac - output power 500 W
• Single-phase input 120 and 230 Vac 127
• Short circuit, overload, over temperature and overvoltage
input and output protection
• Elevated outrush current to ensure the selectivity of
protections and start-up of heavy loads
• Compact dimensions
• Suitable for SELV and PELV circuits 139
• Failure contact with threshold Uout -10% E212719
E203601
80

NOTES BLOCK DIAGRAM


The depth measurement includes rail clamp clearance.
(2) Dual voltage input with selection through external jumper.
L 
(3) Over 45°C apply the following derating:
AC +

+ 
-0.34 A/°C for version C; -0.17 A/°C for version D.

FILTER
PE +
+
(4) For this peak of power, the output voltage does not decrease 
N AC – 
more than 10% of the rated value, however the value of the
current supplied by the power supply also depends on the
line resistance.
PWM

120 Vac selection terminals

VERSIONS Code XCSF500C Code XCSF500D


Output 24 Vdc 20 A –
Output 24 Vdc 20 A redundant version CSF500C
Output 12…15 Vdc 40 A –
Output 48 Vdc 10 A redundant version CSF500D
INPUT TECHNICAL DATA
Input rated voltage 120–230 Vac (range 90…132 Vac / 185…264 Vac) (2)
Frequency 47...63 Hz
Current with nominal lout (Uin 120 / 230 Vac) 4.1 A / 2 A ± 10%
Inrush peak current < 25 A with electronic limiter
Power factor > 0.75 with PFC
Internal protection fuse —
External protection on AC line circuit breaker 16 A characteristic C - fuses: T 15 A
OUTPUT TECHNICAL DATA
Output rated voltage 24 Vdc 48 Vdc
Output adjustable range 24...28 Vdc 45…55 Vdc
Continuous current 20 A at 45°C (3) 10 A at 45°C (3)
Overload limiting current 30 A for >5 s 15 A for >5 s
with Uout >90% Un (4) with Uout >90% Un (4)
Short circuit peak current >50 A for 5 s (4) >50 A for 5 s (4)
Load regulation < 0.5% < 0.5%
Ripple at nominal ratings ≤ 50 mVpp ≤ 50 mVpp
Hold up time (Uin 120 / 230 Vac) >12 ms / >20 ms >12 ms / >20 ms
Overload / short circuit protections hiccup at the overload limit with auto reset/thermal protection
Status display Green LED "DC OK" / failure contact "DC OK" / Red LED "Overload"
Alarm contact threshold 21.6 Vdc (5) 43.2 Vdc (5)
Parallel connection possible possible
Redundant parallel connection already fitted with internal ORing diode already fitted with internal ORing
diode
GENERAL TECHNICAL DATA
Efficiency (Uin 120 / 230 Vac) >92% / >92% >92% / >92%
Dissipated power (Uin 120 / 230 Vac) 42 W / 42 W 42 W / 42 W
Operating temperature range –20...+60°C, with derating over 45°C / thermal protection (3)
Input/output isolation 3 kVac / 60 s SELV output
Input/PE isolation 1.5 kVac / 60 s
Output/PE isolation 0.5 kVac / 60 s
Safety standards EN 60950-1+A1+A2+A12, UL 508
Electromagnetic compatibility EN61000-6-1, EN61000-6-2, EN61000-6-3, EN61000-6-4
MTBF at 25°C and nominal ratings >500'000 h according to SN 29500 / >150'000 h according to MIL Std. HDBK 217F
Overvoltage category / Pollution degree II / 2
Protection degree IP 20 IEC 529, EN60529
Connection type 4 and 6 mm² screw-clamp terminal blocks
Housing material aluminium
Approximate weight 1.3 kg
Mounting information vertical on rail, allow 10 mm spacing between adjacent components
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 —

20
Single-phase switching
power supply 120-230
Vac in IP65 case
• Single-phase input 90…264 Vac and DC 100…345 Vdc
• Short circuit, overload, over temperature and overvoltage 120
input and output protection
• Suitable for installation directly on-board the machine,
requiring no protective coating
• With removable screw-fixed IP65 connector
• Suitable for SELV and PELV circuits 190 80
E203601

NOTES BLOCK DIAGRAM


The depth measurement includes terminal block and rail clamp
clearance.
(1) With an input powered at 100...127 Vdc, using constant
power and Ta> 45°C, the outrush current is reduced by 25%
(2) The value of the current supplied by the power supply also
depends on the line resistance.
(3) Version made to order (not kept in stock); contact our sales
office for availability.

VERSIONS Code XCSF565


Output 24 Vdc 5 A CSF5-65 (3)

INPUT TECHNICAL DATA


Input rated voltage 120–230 Vac (range 90…264 Vac / 100…345 Vdc) (1)
Frequency 47...63 Hz
Current with nominal lout (Uin 120 / 230 Vac) 1.8 A / 1 A ± 10%
Inrush peak current < 20 A
Power factor > 0.7
Internal protection fuse Replaceable T 3.15 A
External protection on AC line circuit breaker 4 A characteristic C - fuses: T 4 A
OUTPUT TECHNICAL DATA
Output rated voltage 24 Vdc
Output adjustable range 23...27.5 Vdc
Continuous current 5 A at 60°C
Overload limiting current 8 A (2)
Short circuit peak current —
Load regulation < 1%
Ripple at nominal ratings ≤ 50 mVpp
Hold up time (Uin 120 / 230 Vac) >10 ms / >20 ms
Overload / short circuit protections hiccup at the overload limit with auto reset/thermal protection
Status display Green LED "DC OK" / failure contact "DC OK"
Alarm contact threshold —
Parallel connection possible
Redundant parallel connection possible with external ORing diode
GENERAL TECHNICAL DATA
Efficiency (Uin 120 / 230 Vac) >86% / >90%
Dissipated power (Uin 120 / 230 Vac) 18.6 W / 12.6 W
Operating temperature range –20...+60°C / thermal protection
Input/output isolation 3 kVac / 60 s SELV output
Input/PE isolation 1.5 kVac / 60 s
Output/PE isolation 0.5 kVac / 60 s
Safety standards EN 60950-1+A1+A2+A12, UL 508
Electromagnetic compatibility EN61000-6-1, EN61000-6-2, EN61000-6-3, EN61000-6-4
MTBF at 25°C and nominal ratings >500'000 h according to SN 29500 / >150'000 h according to MIL Std. HDBK 217F
Overvoltage category / Pollution degree II / 2
Protection degree IP 20 IEC 529, EN60529
Connection type 2.5 mm2 removable screw IP65 connectors
Housing material aluminium
Approximate weight 1.9 kg
Mounting information vertical on rail or screwed to panel
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 —

21
Switching power supply - CSL Series
EASY POWER
Single-phase switching power supply for DIN-rail, for general applications in automation and
installation. Offering excellent value for money, these offer a perfect and convenient solution for uses in
which the powered loads do not require strong peak currents.
They can deliver over +50% of nominal current for a sustained period, keeping the output voltage stable
and ensuring continuity of supply to the system. With these features, this range of power supplies
enables designers to meet the requirements of the Machinery Directive EN 60204-1, allowing
the protection devices connected to the output to trigger quickly, safely and selectively, thus ensuring
continuity of service to the other parts of the system.

Suggested uses
• Civil automation applications
• General applications in plant installations

Main features
• Equipped with a 120-230 Vac input, these are suitable for use in all single-phase networks
• High efficiency reduces energy consumption and the operating temperature of components and
allows use in small panels and severe environmental conditions.
• Power reserve +50% of nominal current, ensuring safety and reliability.
• Output voltage is adjustable and protected against incoming surge generated by inductive loads on
the DC line, and is equipped with a double electronic protection that prevents the powered device
from failing in case of an internal malfunction.
• Short-circuit, overload and thermal protection prevents faults in case of prolonged overload with
high ambient temperatures.
• Construction ensures optimal capacity of ventilation of internal components, extremely reduced
overall dimensions and degree of protection IP20 by accidental contact according to IEC529.
• Offer superior performance, features and reliability compared to other products of a similar power
and cost.

Short-circuit, overload and thermal protection Prevents faults


in case of prolonged overload with high ambient temperatures
Adjustable output voltage
Protected against incoming surge
generated by inductive loads on the
DC line

Power boost Extremely


The output power compact
reaches 120% of dimensions
the nominal value Among the smallest
for several minutes, on the market,
up to 150% in the optimising the
event of overload, use of space in
and up to 300% the panel without
during a short- compromising
circuit, to enable the performance
protection devices
connected to the
output to trigger
quickly, safely and
selectively, without
the use of additional High performance
modules. Reduces the energy consumption and operating temperature of components
and allows for use in small panels and in severe ambient conditions

22
Single-phase switching
power supply 120-230
Vac - output power 85 W
• Single-phase input 90…264 Vac 115
• Short circuit, overload, over temperature and overvoltage
input and output protection
• Ideal for general installation and application
environments
• Suitable for SELV and PELV circuits 128

E203601
39

NOTES BLOCK DIAGRAM


The depth measurement includes terminal block and rail clamp
clearance.
(3) Over 45°C apply a derating of -0.06 A/°C    
(4) For this peak of power, the output voltage does not decrease 

more than 10% of the rated value, however the value of the   


current supplied by the power supply also depends on the    
line resistance.



VERSIONS Code XCSL85C


Output 24 Vdc 3.5 A CSL85C

INPUT TECHNICAL DATA


Input rated voltage 120–230 Vac (range 90…264 Vac)
Frequency 47...63 Hz
Current with nominal lout (Uin 120 / 230 Vac) 1.6A / 0.9 A ± 10%
Inrush peak current < 20 A
Power factor > 0.65
Internal protection fuse Replaceable T 2 A
External protection on AC line circuit breaker 4 A characteristic C - fuses: T 4 A
OUTPUT TECHNICAL DATA
Output rated voltage 24 Vdc
Output adjustable range 23...27.5 Vdc
Continuous current 3.5 A at 45°C (3)
Overload limiting current 5.5 A for >30 s with Uout >90% Un (4)
Short circuit peak current 9 A for 50 ms
Load regulation < 1%
Ripple at nominal ratings 70 mVpp
Hold up time (Uin 120 / 230 Vac) >20 ms / >70 ms
Overload / short circuit protections hiccup at the overload limit with auto reset/thermal protection
Status display Green LED "DC OK"
Alarm contact threshold —
Parallel connection possible
Redundant parallel connection possible with external ORing diode
GENERAL TECHNICAL DATA
Efficiency (Uin 120 / 230 Vac) >86% / >90%
Dissipated power (Uin 120 / 230 Vac) 14 W / 10 W
Operating temperature range –20...+60°C, with derating over 45°C/thermal protection (3)
Input/output isolation 3 kVac / 60 s SELV output
Input/PE isolation 1.5 kVac / 60 s
Output/PE isolation 0.5 kVac / 60 s
Safety standards EN 60950-1+A1+A2+A12, UL 508
Electromagnetic compatibility EN61000-6-1, EN61000-6-2, EN61000-6-3, EN61000-6-4
MTBF at 25°C and nominal ratings >400'000 h according to SN 29500 / >100'000 h according to
MIL Std. HDBK 217F
Overvoltage category / Pollution degree II / 2
Protection degree IP 20 IEC 529, EN60529
Connection type 2.5 mm² removable screw terminal blocks
Housing material aluminium and stainless steel
Approximate weight 400 g
Mounting information vertical on rail, allow 10 mm spacing between adjacent compo-
nents
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 —

23
Single-phase switching
power supply 120-230
Vac - output power 120 W
• Single-phase input 90…264 Vac 115
• Short circuit, overload, over temperature and overvoltage
input and output protection
• Ideal for general installation and application
environments
• Suitable for SELV and PELV circuits 128

E203601 39

NOTES BLOCK DIAGRAM


The depth measurement includes terminal block and rail clamp
clearance.
(3) Over 45°C apply a derating of -0.08 A/°C    

(4) For this peak of power, the output voltage does not decrease

  
more than 10% of the rated value, however the value of the 
current supplied by the power supply also depends on the    

line resistance.



VERSIONS Code XCSL120C


Output 24 Vdc 5 A CSL120C

INPUT TECHNICAL DATA


Input rated voltage 120–230 Vac (range 90…264 Vac)
Frequency 47...63 Hz
Current with nominal lout (Uin 120 / 230 Vac) 1.9 A / 1.1 A ± 10%
Inrush peak current < 20 A
Power factor > 0.65
Internal protection fuse Replaceable T 3.15 A
External protection on AC line circuit breaker 4 A characteristic C - fuses: T 4 A
OUTPUT TECHNICAL DATA
Output rated voltage 24 Vdc
Output adjustable range 23...27.5 Vdc
Continuous current 5 A at 45°C (3)
Overload limiting current 8 A for >30 s with Uout >90% Un (4)
Short circuit peak current 13 A for 50 ms (4)
Load regulation < 1%
Ripple at nominal ratings 30 mVpp
Hold up time (Uin 120 / 230 Vac) >17 ms / >72 ms
Overload / short circuit protections hiccup at the overload limit with auto reset/thermal protection
Status display Green LED "DC OK"
Alarm contact threshold —
Parallel connection possible
Redundant parallel connection possible with external ORing diode
GENERAL TECHNICAL DATA
Efficiency (Uin 120 / 230 Vac) >86% / >90%
Dissipated power (Uin 120 / 230 Vac) 19 W / 13 W
Operating temperature range –20...+60°C, with derating over 45°C / thermal protection (3)
Input/output isolation 3 kVac / 60 s SELV output
Input/PE isolation 1.5 kVac / 60 s
Output/PE isolation 0.5 kVac / 60 s
Safety standards EN 60950-1+A1+A2+A12, UL 508
Electromagnetic compatibility EN61000-6-1, EN61000-6-2, EN61000-6-3, EN61000-6-4
MTBF at 25°C and nominal ratings >400'000 h according to SN 29500 / >100'000 h according to
MIL Std. HDBK 217F
Overvoltage category / Pollution degree II / 2
Protection degree IP 20 IEC 529, EN60529
Connection type 2.5 mm² removable screw terminal blocks
Housing material aluminium and stainless steel
Approximate weight 400 g
Mounting information vertical on rail, allow 10 mm spacing between adjacent compo-
nents
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 —

24
Single-phase switching
power supply 120-230
Vac - output power 240 W
• Single-phase input 120 and 230 Vac 140
• Short circuit, overload, over temperature and overvoltage
input and output protection
• Ideal for general installation and application
environments
• Suitable for SELV and PELV circuits
135
E203601
63.5

NOTES BLOCK DIAGRAM


The depth measurement includes terminal block and rail clamp
clearance.
L 
(2) Dual voltage input with selection through external jumper. AC +

+ 
(3) Over 45°C apply a derating equal to -0.17 A/°C PE FILTER +
+
(4) For this peak of power, the output voltage does not decrease 
N AC – 
more than 10% of the rated value, however the value of the
current supplied by the power supply also depends on the
line resistance.
PWM
(5) Version available since September 2011
120 Vac selection terminals

VERSIONS Code XCSL240C


Output 24 Vdc 10 A CSL240C (5)

INPUT TECHNICAL DATA


Input rated voltage 120–230 Vac (range 90…132 Vac / 185…264 Vac) (2)
Frequency 47...63 Hz
Current with nominal lout (Uin 120 / 230 Vac) 3.5A / 1.8 A ± 10%
Inrush peak current < 35 A
Power factor > 0.6 / >0.85
Internal protection fuse Replaceable T 6.3 A
External protection on AC line circuit breaker 10 A characteristic C - fuses: T 10 A
OUTPUT TECHNICAL DATA
Output rated voltage 24 Vdc
Output adjustable range 23...27.5 Vdc
Continuous current 10 A at 45°C (3)
Overload limiting current 15 A for >30 s with Uout >90% Un (4)
Short circuit peak current >25 A for 400 ms
Load regulation < 1%
Ripple at nominal ratings 50 mVpp
Hold up time (Uin 120 / 230 Vac) >30 ms / >60 ms
Overload / short circuit protections hiccup at the overload limit with auto reset/thermal protection
Status display Green LED "DC OK"
Alarm contact threshold —
Parallel connection possible
Redundant parallel connection possible with external ORing diode
GENERAL TECHNICAL DATA
Efficiency (Uin 120 / 230 Vac) >88% / >90%
Dissipated power (Uin 120 / 230 Vac) 32 W / 27 W
Operating temperature range –20...+60°C, with derating over 45°C / thermal protection (3)
Input/output isolation 3 kVac / 60 s SELV output
Input/PE isolation 1.5 kVac / 60 s
Output/PE isolation 0.5 kVac / 60 s
Safety standards EN 60950-1+A1+A2+A12, UL 508
Electromagnetic compatibility EN61000-6-1, EN61000-6-2, EN61000-6-3, EN61000-6-4
MTBF at 25°C and nominal ratings >400'000 h according to SN 29500 / >100'000 h according to
MIL Std. HDBK 217F
Overvoltage category / Pollution degree II / 2
Protection degree IP 20 IEC 529, EN60529
Connection type 2.5 mm² removable screw terminal blocks
Housing material aluminium and stainless steel
Approximate weight 920 g
Mounting information vertical on rail, allow 10 mm spacing between adjacent compo-
nents
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 —

25
Single-phase switching
power supply 230 Vac -
output power 480 W
• Single-phase input 230 Vac
140
• Short circuit, overload, over temperature and overvoltage
input and output protection
• Ideal for general installation and application
environments
• Suitable for SELV and PELV circuits
137
E203601 73

NOTES BLOCK DIAGRAM


The depth measurement includes terminal block and rail clamp
clearance.
(3) Over 45°C apply a derating equal to approximately 16 W/°C
(4) For this peak of power, the output voltage does not decrease
more than 10% of the rated value, however the value of the
current supplied by the power supply also depends on the
line resistance.

VERSIONS Code XCSL481C


Output 24 Vdc 20 A CSL481C

INPUT TECHNICAL DATA


Input rated voltage 230 Vac (range 187…264 Vac) (2)
Frequency 47...63 Hz
Current with nominal lout (Uin 120 / 230 Vac) –/2A
Inrush peak current <20 A
Power factor > 0.95
Internal protection fuse -
External protection on AC line circuit breaker 6 A characteristic C - fuses: T 6.3 A
OUTPUT TECHNICAL DATA
Output rated voltage 24 Vdc
Output adjustable range 23...27.5 Vdc
Continuous current 20 A at 45°C (3)
Overload limiting current 28 A (4)
Short circuit peak current 50 A for 0.3 s
Load regulation < 1%
Ripple at nominal ratings ≤ 100 mVpp
Hold up time (Uin 120 / 230 Vac) – / >20 ms
Overload / short circuit protections hiccup at the overload limit with auto reset/thermal protection
Status display Green LED "DC OK"
Alarm contact threshold 21.6 Vdc
Parallel connection possible
Redundant parallel connection possible with external ORing diode
GENERAL TECHNICAL DATA
Efficiency (Uin 120 / 230 Vac) – / >92%
Dissipated power (Uin 120 / 230 Vac) – / 42 W
Operating temperature range –20...+60°C, with derating over 45°C / thermal protection (3)
Input/output isolation 3 kVac / 60 s SELV output
Input/PE isolation 2 kVac / 60 s
Output/PE isolation 0.5 kVac / 60 s
Safety standards EN 60950-1+A11, UL 508
Electromagnetic compatibility EN61000-6-2, EN61000-6-4
MTBF at 25°C and nominal ratings >500'000 h according to SN 29500 / >150'000 h according to
MIL Std. HDBK 217F
Overvoltage category / Pollution degree II / 2
Protection degree IP 20 IEC 529, EN60529
Connection type 2.5 mm² removable screw terminal blocks
Housing material aluminium and stainless steel
Approximate weight 1 kg
Mounting information vertical on rail, allow 10 mm spacing between adjacent compo-
nents
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 —

26
UNIVERSAL POWER
DIN-rail based switching power supply with universal input 185…550 Vac single/2 /3-phase for
industrial automation and process control applications. Input circuit technology makes these immune to
Greater reliability
overvoltage caused by faults in 3-phase networks with neutral, increasing the reliability of application.
This series offers greater reliability in industrial
This series offers greater reliability in industrial environments compared to single-phase power supplies. environments compared to single-phase power
The input stage uses components with an operating voltage of 900 V, offering greater resistance to the supplies.
voltage peaks present in industrial networks than single-phase components. The ability to operate from 185 The input stage uses components with an
to 550 Vac allows these power supplies to be used in both 230 V single-phase networks and 400 V 3-phase operating voltage of 900 V, offering greater
networks. resistance to the voltage peaks present in
industrial networks than single-phase
components.
Suggested uses The ability to operate from 185 to 550 Vac
• Wherever maximum flexibility of use is required in single- or 3-phase networks makes these power supplies immune to network
• Applications in industrial automation and process control faults:
• Uses with heavy loads With the output powered at 230 Vac (1L-N), in
case of a short in another device connected to
• Civil automation applications L2-N, the neutral is increased to around 400
Vac and the input is powered phase-phase
Main features until the protection is opened, which in most
• The 185…550 Vac extended range input is compatible with 230…240 Vac single-phase power, 208 cases occurs within 300 ms; this is one of the
Vac 2-phase and 400…500 Vac 2-phase and 3-phase for maximum adaptability to AC networks, most frequent causes of malfunction in 230
eliminating the need for an isolation transformer. Vac single-phase power supplies in industrial
environments (figures 1 and 2)
• The 2-phase input offers reduced bulk, wiring, installation costs and panel space. Another type of fault in 230 Vac single-phase
• Eliminates the need for a network voltage adaptation transformer. devices with phase-neutral power is due to the
• Versions with DC OK failure contact accidental disconnection or interruption of the
• High efficiency reduces energy consumption and the operating temperature of components and allows panel neutral by the plant neutral: with no return
to the star point, the neutral increases to phase
use in small panels and severe environmental conditions. voltage and applies to single-phase loads of
• Large power reserve allows 5 seconds of current to be supplied at least +50% higher than the rated around 400 Vac, and malfunction is inevitable.
value, ensuring safety and reliability.
• The output is adjustable and protected against incoming surge from the DC line, and is equipped with
electronic protection that turns off the output in case of an internal malfunction.
• Short-circuit and overload protection designed to supply peak currents of more than 150% of the rated
value required by heavy loads, while the thermal protection prevents faults in case of prolonged overload
with high ambient temperatures.
• Construction ensures excellent ventilation capacity of internal components, with reduced sizes and a
degree of protection from accidental contacts of IP20 per IEC529.
• Thanks to their high performance and excellent ventilation, they are among the smallest on the market.

185…550 Vac wide range input


Compatible with 230…240 Vac single-phase
power, 208 Vac 2-phase and 400…500 Vac Power boost
2-phase and 3-phase for maximum The output power reaches
adaptability to AC networks, 120% of the nominal value for
eliminating the need for several minutes, up to 150%
an isolation transformer. in the event of overload, and Typical application with 3-phase network with
up to 250% during a short- neutral. This is used to obtain a voltage of
circuit, to enable the protection 230 Vac to power loads (a single lamp in the
devices connected to the example) and power supplies.
output to trigger quickly, safely
and selectively, without the use
2-phase input of additional modules.
Reduces clutter, wiring,
installation costs

High performance
Reduces the energy
consumption and operating
temperature of components
and allows for use in small
panels A single short-circuit on the load will raise the
neutral potential and all devices connected to
it will be powered between two phases, i.e. at
Increased reliability in industrial environments around 340...400 Vac rather than 230 Vac.
The input stage uses components with an operating voltage of 900 V,
more resistant to the voltage peaks found in industrial networks

27
1 or 2-phase switching power
supply 230-400-500
Vac - output power 120 W
• Single-phase and 2-phase input 185...550 Vac 115
• High reliability and surge immunity for network failures
• Short circuit, overload, over temperature and overvoltage input and
output protection
• Elevated outrush current to ensure the selectivity of protections and
start-up of heavy loads
130
• High efficiency and low consumption
• Suitable for SELV and PELV circuits E203601 39

NOTES BLOCK DIAGRAM


The depth measurement includes terminal block and rail clamp 
       

clearance. 
  
(1) Version made to order (not kept in stock); contact our sales 

office for availability.


 

(2) 550 Vdc max for UL508 



(3) Over 45°C apply a derating equal to approximately 3 W/°C 
  
(4) For this peak of power, the output voltage does not decrease 
more than 10% of the rated value, however the value of the 
current supplied by the power supply also depends on the
line resistance.

VERSIONS Code XCSW121C Code XCSW121B


Output 24 Vdc 5 A CSW121C
Output 12…15 Vdc 7 A CSW121B
Output 48 Vdc 2.5 A redundant version -
Output 72 Vdc 1.5 A redundant version
INPUT TECHNICAL DATA
Input rated voltage 1-2x 230-400-500 Vac (range 187…550 Vac / 270…725 Vdc) (2)
Frequency 47...63 Hz
Current with nominal lout (Uin 230 / 400 Vac) 1.1 A / 0.55 A
Inrush peak current < 20 A
Power factor > 0.65
Internal protection fuse –
External protection on AC line circuit breaker 2x 6 A characteristic C - fuse: 2x T 4 A
OUTPUT TECHNICAL DATA
Output rated voltage 24 Vdc 12…15 Vdc
Output adjustable range 24...27.5 Vdc 12…15 Vdc
Continuous current 5 A (3) 8 A at 12 Vdc / 7 A at 15 Vdc
Overload limiting current 7.5 A for >30 s 10 A for >30 s
with Uout >90% Un with Uout >90% Un
Short circuit peak current 14 A for 0.4 s (4) 20 A for 0.4 s (4)
Load regulation < 1% < 1%
Ripple at nominal ratings ≤ 100 mVpp ≤ 100 mVpp
Hold up time (Uin 230 / 400 Vac) >20 ms / >80 ms >20 ms / >80 ms
Overload / short circuit protections hiccup at the overload limit with auto reset/thermal protection
Status display Green LED "DC OK" / failure contact "DC OK" / Red LED "Overload"
Alarm contact threshold 21.6 Vdc 10.8 Vdc
Parallel connection possible possible
possible with external ORing possible with external ORing
Redundant parallel connection
diode diode
GENERAL TECHNICAL DATA
Efficiency (Uin 230 / 400 Vac) >87% / >87% >84% / >86%
Dissipated power (Uin 230 / 400 Vac) 18 W / 18 W 20 W / 17 W
Operating temperature range –20...+60°C, with derating over 45°C / thermal protection (3)
Input/output isolation 3 kVac / 60 s SELV output
Input/PE isolation 2 kVac / 60 s
Output/PE isolation 0.5 kVac / 60 s
Safety standards EN 60950-1+A1+A2+A12, UL 508
Electromagnetic compatibility EN61000-6-1, EN61000-6-2, EN61000-6-3, EN61000-6-4
MTBF at 25°C and nominal ratings >500'000 h according to SN 29500 / >150'000 h according to MIL Std. HDBK 217F
Overvoltage category / Pollution degree II / 2
Protection degree IP 20 IEC 529, EN60529
Connection type 2.5 mm² removable screw terminal blocks
Housing material aluminium and stainless steel
Approximate weight 600 g
Mounting information vertical on rail, allow 10 mm spacing between adjacent components
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 —

28
1, 2 or 3-phase switching power
supply 230-400-500 Vac - output
power 240 W
• Single-phase, 2-phase and 3-phase input 185…550 Vac 115
• High reliability and surge immunity for network failures
• Short circuit, overload, over temperature and overvoltage input and
output protection
• Elevated outrush current to ensure the selectivity of protections and
start-up of heavy loads
130
• High efficiency and low consumption
• Suitable for SELV and PELV circuits E203601
55

NOTES BLOCK DIAGRAM


  

The depth measurement includes terminal block and rail clamp
clearance.    
(1) Version made to order (not kept in stock); contact our sales  


office for availability.    

(2) 550 Vdc max for UL508 
   
(3) Over 50°C apply a derating equal to approximately 3 W/°C
(4) For this peak of power, the output voltage does not decrease 

more than 10% of the rated value, however the value of the
current supplied by the power supply also depends on the
line resistance.
(5) Version CSW241G not suitable for SELV applications.

VERSIONS Code XCSW241C Code XCSW241B Code XCSW241DP Code XCSW241G


Output 24 Vdc 10 A CSW241C
Output 12…15 Vdc 16...15 A CSW241B
Output 48 Vdc 5 A redundant version CSW241DP (1)
Output 72 Vdc 3.3 A redundant version CSW241G (1) (5)
INPUT TECHNICAL DATA
Input rated voltage 1-2-3x 230-400-500 Vac (range 185…550 Vac / 270…770 Vdc) (2)
Frequency 47...63 Hz
Current with nominal lout (Uin 230 / 400 Vac) 2A/1A
Inrush peak current < 20 A
Power factor > 0.65
Internal protection fuse –
External protection on AC line circuit breaker 2-3x 6 A characteristic C - fuse: 2-3x T 6.3 A
OUTPUT TECHNICAL DATA
Output rated voltage 24 Vdc 12…15 Vdc 48 Vdc 72 Vdc
Output adjustable range 24...27.5 Vdc 12…15 Vdc 45…55 Vdc 72…85 Vdc
Continuous current 10 A at 50°C (3) 16 A at 12 Vdc / 15 A at 15 5 A at 50°C (3) 3.5 A (3)
Vdc
Overload limiting current 15 A for >6 s 20…18 A for >6 s 6 A for >6 s 5 A for >6 s
with Uout >90% Un (4) with Uout >90% Un (4) with Uout >90% Un (4) with Uout >90% Un (4)
Short circuit peak current 38 A for 0.5 s (4) 34 A A for 0.5 s (4) 18 A for 0.5 s (4) 13 A for 0.5 s (4)
Load regulation < 1% < 1% < 1% < 1%
Ripple at nominal ratings ≤ 100 mVpp ≤ 100 mVpp 100 mVpp ≤ 100 mVpp
Hold up time (Uin 230 / 400 Vac) >15 ms / >100 ms >15 ms / >100 ms >15 ms / >100 ms >15 ms / >100 ms
Overload / short circuit protections hiccup at the overload limit with auto reset/thermal protection
Status display Green LED "DC OK" / failure contact "DC OK" / Red LED "Overload"
Alarm contact threshold 21.6 Vdc 10.8 Vdc 43.2 Vdc 64.8 Vdc
Parallel connection possible possible possible possible
possible with external ORing possible with external ORing already fitted with internal ORing already fitted with
Redundant parallel connection
diode diode diode internal ORing diode
GENERAL TECHNICAL DATA
Efficiency (Uin 230 / 400 Vac) >91% / >92% >89% / >90% >91% / >92% >92% / >93%
Dissipated power (Uin 230 / 400 Vac) 24 W / 21 W 22 W / 20 W 24 W / 21 W 22 W / 19 W
Operating temperature range –20...+60°C, with derating over 50°C / thermal protection (3)
Input/output isolation 3 kVac / 60 s SELV output (5)
Input/PE isolation 2 kVac / 60 s
Output/PE isolation 0.5 kVac / 60 s
Safety standards EN 60950-1+A1+A2+A12, UL 508
Electromagnetic compatibility EN61000-6-1, EN61000-6-2, EN61000-6-3, EN61000-6-4
MTBF at 25°C and nominal ratings >500'000 h according to SN 29500 / >150'000 h according to MIL Std. HDBK 217F
Overvoltage category / Pollution degree II / 2
Protection degree IP 20 IEC 529, EN60529
Connection type 2.5 mm² removable screw terminal blocks
Housing material aluminium and stainless steel
Approximate weight 1 kg
Mounting information vertical on rail, allow 10 mm spacing between adjacent components
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 —

29
1, 2 or 3-phase switching power
supply 230-400-500 Vac - output
power 480 W
• Single-phase, 2-phase and 3-phase input 185…550 Vac 140
• High reliability and surge immunity for network failures
• Short circuit, overload, over temperature and overvoltage input and
output protection
• Elevated outrush current to ensure the selectivity of protections and
start-up of heavy loads
137
• High efficiency and low consumption
• Suitable for SELV and PELV circuits E203601 73

NOTES BLOCK DIAGRAM


The depth measurement includes terminal block and rail clamp
clearance.
(1) Version made to order (not kept in stock); contact our sales
office for availability.
(2) 550 Vdc max for UL508
(3) Over 45°C apply a derating equal to approximately 16 W/°C
(4) For this peak of power, the output voltage does not decrease
more than 10% of the rated value, however the value of the
current supplied by the power supply also depends on the
line resistance.
(5) Version with 72 V output not suitable for SELV applications

VERSIONS Code XCSW481C Code XCSW481D XCSW481G


Output 24 Vdc 20 A CSW481C
Output 12…15 Vdc 40 A -
Output 48 Vdc 10 A CSW481D
Output 72 Vdc 6 A CSW481G (1) (5)
INPUT TECHNICAL DATA
Input rated voltage 1-2-3x 230-400-500 Vac (range 187…550 Vac / 250…725 Vdc) (2)
Frequency 47...63 Hz
Current with nominal lout (Uin 230 / 400 Vac) 2.2 A / 1 A
Inrush peak current <20 A / <40 A
Power factor > 0.95
Internal protection fuse –
External protection on AC line circuit breaker 1-2-3x 6 A characteristic C - fuse: 1-2-3x T 6.3 A
OUTPUT TECHNICAL DATA
Output rated voltage 24 Vdc 48 Vdc 72 Vdc
Output adjustable range 23.3...27.5 Vdc 45…55 Vdc 72…85 Vdc
Continuous current 20 A at 45°C (3) 10 A at 45°C (3) 6 A at 45°C (3)
Overload limiting current 28 A for >5 s 14 A for >5 s 9 A for >5 s
with Uout >90% Un (4) with Uout >90%Un (4) with Uout >90% Un (4)
Short circuit peak current 50 A for 0.3 s (4) 25 A for 0.3 s (4) 12 A for 0.3 s (4)
Load regulation < 1% < 1% < 1%
Ripple at nominal ratings ≤ 100 mVpp ≤ 100 mVpp ≤ 100 mVpp
Hold up time (Uin 230 / 400 Vac) >20 ms / >20 ms >20 ms / >20 ms >20 ms / >20 ms
Overload / short circuit protections hiccup at the overload limit with auto reset/thermal protection
Status display Green LED "DC OK" / failure contact "DC OK" / Red LED "Overload"
Alarm contact threshold 21.6 Vdc 43.2 Vdc 64.8 Vdc
Parallel connection possible possible possible
possible with external ORing possible with external ORing possible with external ORing
Redundant parallel connection
diode diode diode
GENERAL TECHNICAL DATA
Efficiency (Uin 230 / 400 Vac) >92% / >92% >92% / >92% >91% / >91%
Dissipated power (Uin 230 / 400 Vac) 42 W / 42 W 42 W / 42 W 42 W / 42 W
Operating temperature range –20...+60°C, with derating over 50°C / thermal protection (3)
Input/output isolation 3 kVac / 60 s SELV output (5)
Input/PE isolation 2 kVac / 60 s
Output/PE isolation 0.5 kVac / 60 s
Safety standards EN 60950-1+A11, UL 508
Electromagnetic compatibility EN61000-6-2, EN61000-6-4
MTBF at 25°C and nominal ratings >500'000 h according to SN 29500 / >150'000 h according to MIL Std. HDBK 217F
Overvoltage category / Pollution degree II / 2
Protection degree IP 20 IEC 529, EN60529
Connection type 2.5 mm² removable screw terminal blocks
Housing material aluminium and stainless steel
Approximate weight 1 kg
Mounting information vertical on rail, allow 10 mm spacing between adjacent components
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 —

30
Single-/two-phase switching power
supplies 230-400-500
Vac - output power 960 W
• Single-phase, two-phase and three-phase input 185…480 Vac 127
• High reliability and surge immunity for network failures
• Short circuit, overload, overtemperature and surge input and output
protection
• Elevated outrush current to ensure the selectivity of protections and
start-up of heavy loads
139
• High efficiency and low consumption
• Suitable for SELV and PELV circuits 80

NOTES BLOCK DIAGRAM


The depth measurement includes terminal block and rail clamp
clearance.
(1) Version made to order (not kept in stock); contact our sales
office for availability.
(2) Over 45°C apply a derating equal to approximately 32 W/°C
(3) For this peak of power, the output voltage does not decrease
more than 10% of the rated value, however the value of the
current supplied by the power supply also depends on the
line resistance.
(4) Available with bridge

VERSIONS Code XCSW960CP


Output 24 Vdc 40 A redundant version CSW960CP
-

TECHNICAL DATA INPUT


Nominal input voltage 1x 230 Vac (range 180…264 Vac / 250…370 Vdc) 2x 400-500 Vac (range 360…550 Vac / 550…775 Vdc) (4)
Frequency 47...63 Hz
Current with nominal lout (Uin 230 / 400 Vac) 4.7A at 230 Vac / 4A at 400 Vac
Inrush peak current <16 A
Power factor (at 230 Vac) > 0.6
Internal protection fuse –
External protection on the AC line circuit breaker 1-2x 10 A characteristic C - fuse: 1-2x T 10 A
TECHNICAL DATA OUTPUT
Nominal output voltage 24 Vdc
Output adjustable range 23...27.5 Vdc
Continuous current 40 A at 45°C (2)
Overload limiting current 50 A for >5 s with Uout >90%
Un (4)
Short circuit peak current 65 A for 5 s (3)
Load adjustment < 4%
Ripple at nominal ratings ≤ 200 mVpp
Hold up time (Uin 230 / 400 Vac) >20 ms
Protection against short circuits and overload hiccup at the overload limit with auto reset /  thermal protection
Status signals Green LED "DC OK" / failure contact "DC OK" / Red LED "Overload"
Activation threshold of the failure contact 21.6 Vdc
Parallel connection possible
possible with external ORing
Redundant parallel connection
diode
GENERAL TECHNICAL DATA
Efficiency (Uin 230 / 400 Vac) >90% at 230 Vac
Dissipated power (Uin 230 / 400 Vac) <100 W at 230 Vac
Operating temperature range –20...+60°C, with derating above 45°C/thermal protection (2)
Input/Output insulation 3 kVac / 60 s SELV output
Input/PE insulation 2 kVac / 60 s
Output/PE insulation 1 kVac / 60 s
Safety standards EN 60950-1+A1+A2+A12
Electromagnetic compatibility EN61000-6-1, EN61000-6-2, EN61000-6-3, EN61000-6-4
MTBF at 25°C and nominal ratings >500'000 h according to SN 29500 / >150'000 h according to MIL Std. HDBK 217F
Surge category / degree of pollution II / 2
Degree of protection IP 20 IEC 529, EN60529
Connection type Input: 4 mm² screw terminal blocks / Output: 10 mm² screw terminal blocks
Container material Aluminium
Approximate weight 1.2 Kg
Assembly vertical on rail, space 10 mm from adjacent components
ACCESSORIES FOR ASSEMBLY
Mounting rail compliant with IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail compliant with IEC60715/G32 —

31
Switching power supply - CSG Series
TRIPLE POWER
400…500 Vac 3-phase switching power supply for industrial automation applications. They can
deliver over +50% of nominal current for a sustained period, keeping the output voltage stable and Special power supplies for engines
ensuring continuity of supply to the system. Equipped with voltage threshold controlled failure contact DC, Brushless, and relative drives
which is triggered when the voltage falls below 90% of the rated value.
With these features and numerous international certifications, this range of power supplies
New 48Vdc, 72-85Vdc, and 110-180Vdc
enables designers to meet the requirements of the Machinery Directive EN 60204-1, allowing
models have been introduced, designed to
the protection devices connected to the output to trigger quickly, safely and selectively, thus ensuring
reliably power engines in DC. They:
continuity of service to the other parts of the system.
• supply peak power equal to even 4-5 times
the nominal current, which is required by
Suggested uses
the engine during the peak phase
• Applications in machine automation with high command and control voltage reliability and safety
• have an output stage protected from
requirements
overvoltage generated by the engines
• In applications which require selectable overcurrent protections on DC lines
and drives during braking, which could
• Industrial automation applications
otherwise cause malfunctions or cause the
• Uses with heavy loads
power supply to lose control over output
voltage stability
Main features
• Provide output voltage at 48Vdc, and
• With 340…550 Vac/507…770 Vdc input, making them suitable for use on all power supply
72…85Vdc. By increasing the voltage
networks.
of the engine power supply, the same
• High efficiency reduces energy consumption and the operating temperature of components and
power can be obtained at lower current,
allows use in small panels and severe environmental conditions.
with notable advantages for performance,
• Large power reserve allows for delivery of at least +50% of nominal current for 5 seconds
engine construction, connection wires, and
maintaining the output voltage stable, ensuring safety and reliability.
drives.
• Output voltage is adjustable and protected against incoming surge from the DC line, and is equipped
with a double electronic protection that prevents damage to the powered device in case of an
internal malfunction.
• Short-circuit and overload protection designed to deliver peak currents more than 150% higher than
the rated value required by heavy loads.
• Thermal protection prevents faults in case of prolonged overload with high ambient temperatures.
• Construction ensures optimal capacity of ventilation of internal components, extremely reduced
overall dimensions and degree of protection IP20 by accidental contact according to IEC529.

Integrated smart alarm contact


Notifies when the output voltage falls below 90% Super compact size
of the rated value once a threshold is surpassed Among the smallest on the market,
optimising the use of space in the panel
without compromising performance

Power boost
The output power Very high
reaches 120% of efficiency
the nominal value Designed to
for several minutes, save energy and
up to 150% in the reduce operating
event of overload, temperature
and up to 250%
during a short-
circuit, to enable the
protection devices
connected to the
output to trigger
quickly, safely and
selectively, without
the use of additional
modules. Wide range
The widest range on the market, with power ratings
from 120 to 2400W and output voltages of 24, 48 and
72 V, for uses including powering special motors
32
3-phase switching power
supply 400-500 Vac - output
power 480 W
• 3-phase 340...550 Vac or 2-phase with derating 140
• Short circuit, overload, over temperature and overvoltage input
and output protection
• Elevated outrush current to ensure the selectivity of protections
and start-up of heavy loads
• High efficiency and low consumption
137
• Suitable for SELV and PELV circuits
E203601 73

NOTES BLOCK DIAGRAM


The depth measurement includes rail clamp clearance.
(3) Over 45°C apply a derating equal to approximately 16 W/°C
(4) For this peak of power, the output voltage does not decrease
more than 10% of the rated value, however the value of the
current supplied by the power supply also depends on the
line resistance.

VERSIONS Code XCSG481C


Output 24 Vdc 20 A CSG481C
Output 12…15 Vdc 40 A —
Output 48 Vdc 10 A —
Output 72 Vdc 6 A —
INPUT TECHNICAL DATA
Input rated voltage 3x 400–500 Vac (range 340…550 Vac)
Frequency 47...63 Hz
Current with nominal lout (Uin 400 / 500 Vac) 1.2 A / 0.8 A
Inrush peak current <40 A
Power factor > 0.95
Internal protection fuse —
External protection on AC line circuit breaker 3x 6 A characteristic C - fuse: 3x T 6.3 A
OUTPUT TECHNICAL DATA
Output rated voltage 24 Vdc
Output adjustable range 23.3...27.5 Vdc
Continuous current 20 A at 45°C (3)
Overload limiting current 28 A for >5 s with Uout
>90%Un (4)
Short circuit peak current 50 A for 0.3 s (4)
Load regulation < 1%
Ripple at nominal ratings ≤ 100 mVpp
Hold up time (Uin 400 / 500 Vac) >50 ms / >50 ms
Overload / short circuit protections hiccup at limit current with auto reset/thermal protection (3)
Status display Green LED "DC OK" / failure contact "DC OK"
Alarm contact threshold 21.6 Vdc
Parallel connection possible
possible with external ORing
Redundant parallel connection
diode
GENERAL TECHNICAL DATA
Efficiency (Uin 400 / 500 Vac) >93% / >92%
Dissipated power (Uin 400 / 500 Vac) 36 W / 42 W
Operating temperature range –20...+60°C, with derating over 50°C / thermal protection (3)
Input/output isolation 3 kVac / 60 s SELV output
Input/PE isolation 2 kVac / 60 s
Output/PE isolation 0.5 kVac / 60 s
Safety standards EN 60950-1+A11, UL 508
Electromagnetic compatibility EN61000-6-2, EN61000-6-4
MTBF at 25°C and nominal ratings >500'000 h according to SN 29500 / >150'000 h according to MIL Std. HDBK 217F
Overvoltage category / Pollution degree II / 2
Protection degree IP 20 IEC 529, EN60529
Connection type 2.5 mm² fixed screw terminal blocks
Housing material aluminium
Approximate weight 1 kg
Mounting information vertical on rail, allow 10 mm spacing between adjacent components
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 —

33
3-phase switching power
supply 400-500 Vac - output
power 500 W 127
• 3-phase 340...550 Vac or 2-phase with derating
• Short circuit, overload, over temperature and overvoltage input
and output protection
• Elevated outrush current to ensure the selectivity of protections 139
and start-up of heavy loads 80
• High efficiency and low consumption
• Suitable for SELV and PELV circuits
E203601

NOTES BLOCK DIAGRAM


The depth measurement includes rail clamp clearance.

            
(3) Over 50°C apply a derating equal to approximately 6 W/°C
(4) For this peak of power, the output voltage does not decrease    
more than 10% of the rated value, however the value of the 




current supplied by the power supply also depends on the
  


line resistance.    

 

 ­

VERSIONS Code XCSG500C


Output 24 Vdc 20 A CSG500C
Output 12...15 Vdc 40 A -
Output 48 Vdc 10 A redundant version -
Output 72 Vdc 6.7 A redundant version
INPUT TECHNICAL DATA
Input rated voltage 3x 400–500 Vac (range 340…550 Vac)
Frequency 47...63 Hz
Current with nominal lout (Uin 400 / 500 Vac) 1 A / 0.6 A
Inrush peak current < 35 A
Power factor > 0.75 with PFC
Internal protection fuse —
External protection on AC line circuit breaker 10 A characteristic C - fuses: 3x T 10 A
OUTPUT TECHNICAL DATA
Output rated voltage 24 Vdc
Output adjustable range 24...28 Vdc
Continuous current 20 A at 50°C (3)
Overload limiting current >30 A for >5 s
with Uout >90% Un (4)
Short circuit peak current >60 A for 5 s (4)
Load regulation < 0.5%
Ripple at nominal ratings ≤ 100 mVpp
Hold up time (Uin 400 / 500 Vac) >15 ms / >30 ms
Overload / short circuit protections limit current hiccup with auto reset/thermal protection
Status display Green LED "DC OK" / failure contact "DC OK" / Red LED "Overload"
Alarm contact threshold <21.6 Vdc
Parallel connection possible
possible with external ORing
Redundant parallel connection
diode
GENERAL TECHNICAL DATA
Efficiency (Uin 400 / 500 Vac) >93% / >93%
Dissipated power (Uin 400 / 500 Vac) 36 W / 36 W
Operating temperature range –20...+60°C, with derating over 50°C / thermal protection (3)
Input/output isolation 3 kVac / 60 s SELV output (5)
Input/PE isolation 2 kVac / 60 s
Output/PE isolation 0.5 kVac / 60 s
Safety standards EN 60950-1+A1+A2+A12, UL 508
Electromagnetic compatibility EN61000-6-1, EN61000-6-2, EN61000-6-3, EN61000-6-4
MTBF at 25°C and nominal ratings >500'000 h according to SN 29500 / >150'000 h according to MIL Std. HDBK 217F
Overvoltage category / Pollution degree II / 2
Protection degree IP 20 IEC 529, EN60529
Connection type 6 mm² fixed screw terminal blocks
Housing material aluminium
Approximate weight 1.3 Kg
Mounting information vertical on rail, allow 10 mm spacing between adjacent components
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 —

34
3-phase switching power
supply 400-500 Vac - output
power 720 W 127
• 3-phase 340...550 Vac or 2-phase with derating
• Short circuit, overload, over temperature and overvoltage input
and output protection
• Elevated outrush current to ensure the selectivity of protections 139
and start-up of heavy loads 80
• High efficiency and low consumption
• Suitable for SELV and PELV circuits
E203601

NOTES BLOCK DIAGRAM


The depth measurement includes rail clamp clearance.
(4) For this peak of power, the output voltage does not decrease 
            

more than 10% of the rated value, however the value of the
current supplied by the power supply also depends on the    



line resistance.


   


   

 

 ­

VERSIONS Code XCSG720C


Output 24 Vdc 30 A CSG720C
Output 12...15 Vdc 60 A
Output 48 Vdc 15 A redundant version
Output 72 Vdc 10 A redundant version
INPUT TECHNICAL DATA
Input rated voltage 3x 400–500 Vac (range 340…550 Vac)
Frequency 47...63 Hz
Current with nominal lout (Uin 400 / 500 Vac) 1.4 A / 1.1 A
Inrush peak current < 30 A
Power factor > 0.75
Internal protection fuse —
External protection on AC line magneto-thermal 3x 10 A curve C - fuses: 3x T 10 A
OUTPUT TECHNICAL DATA
Output rated voltage 24 Vdc
Output adjustable range 24…28 Vdc
Continuous current 30 A at 50°C (3)
Overload limiting current 45 A for >5 s
with Uout >90% Un (4)
Short circuit peak current >80 A for 1.5 s (4)
Load regulation < 1%
Ripple at nominal ratings 100 mVpp
Hold up time (Uin 400 / 500 Vac) >10 ms / >15 ms
Overload / short circuit protections limit current hiccup with auto reset/thermal protection/ASSIL protection
Status display Green LED "DC OK" / failure contact "DC OK" / Red LED "Overload"
Alarm contact threshold <21.6 Vdc
Parallel connection possible
possible with external ORing
Redundant parallel connection
diode
GENERAL TECHNICAL DATA
Efficiency (Uin 400 / 500 Vac) >92% / >92%
Dissipated power (Uin 400 / 500 Vac) 60 W / 60 W
Operating temperature range –20...+60°C / thermal protection (3)
Input/output isolation 3 kVac / 60 s SELV output
Input/PE isolation 2 kVac / 60 s
Output/PE isolation 0.5 kVac / 60 s
Safety standards EN 60950-1+A1+A2+A12, UL 508
Electromagnetic compatibility EN61000-6-1, EN61000-6-2, EN61000-6-3, EN61000-6-4
MTBF at 25°C and nominal ratings >500'000 h according to SN 29500 / >150'000 h according to MIL Std. HDBK 217F
Overvoltage category / Pollution degree II / 2
Protection degree IP 20 IEC 529, EN60529
Connection type 6 mm² fixed screw terminal blocks
Housing material aluminium
Approximate weight 1.3 Kg
Mounting information vertical on rail, allow 10 mm spacing between adjacent components
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 —

35
3-phase switching power
supply 400-500 Vac - output
power 960 W 127

• 3-phase 340...550 Vac or 2-phase with derating


• Short circuit, overload, over temperature and overvoltage input
and output protection
• Elevated outrush current to ensure the selectivity of protections 139
and start-up of heavy loads 80
• High efficiency and low consumption
• Suitable for SELV and PELV circuits
E203601

NOTES BLOCK DIAGRAM


The depth measurement includes rail clamp clearance.
(3) Over 45°C apply a derating equal to approximately 18 W/°C 
            

(4) For this peak of power, the output voltage does not decrease
more than 10% of the rated value, however the value of the    



current supplied by the power supply also depends on the


   

line resistance.   


(5) CSG960G version not suitable for SELV applications
 

 ­

VERSIONS Code XCSG960C Code XCSG960D Code XCSG960G


Output 24 Vdc 40 A CSG960C
Output 12...15 Vdc 80 A —
Output 48 Vdc 20 A redundant version CSG960D
Output 72 Vdc 13.3 A redundant version (5) CSG960G (5)
INPUT TECHNICAL DATA
Input rated voltage 3x 400–500 Vac (range 340…550 Vac)
Frequency 47...63 Hz
Current with nominal lout (Uin 400 / 500 Vac) 2.2 A / 1.1 A
Inrush peak current < 20 A
Power factor > 0.65
Internal protection fuse —
External protection on AC line circuit breaker 3x 10 A characteristic C - fuses: 3x T 10 A
OUTPUT TECHNICAL DATA
Output rated voltage 24 Vdc 48 Vdc 72 Vdc
Output adjustable range 24…28 Vdc 45…55 Vdc 72…85 Vdc
Continuous current 40 A at 50°C (3) 20 A at 50°C (3) 13.3 A at 50°C (3)
Overload limiting current 56 A for >5 s 28 A for >5 s 18.6 A for >5 s
with Uout >90% Un (4) with Uout >90% Un (4) with Uout >90% Un (4)
Short circuit peak current >90 A for 5 s (4) >70 A for 5 s (4) >30 A for 5 s (4)
Load regulation < 1% < 1% < 1%
Ripple at nominal ratings 100 mVpp 100 mVpp ≤ 100 mVpp
Hold up time (Uin 400 / 500 Vac) >10 ms / >15 ms >10 ms / >15 ms >15 ms / >18 ms
Overload / short circuit protections limit current hiccup with auto reset/thermal protection
Status display Green LED "DC OK" / failure contact "DC OK" / Red LED "Overload"
Alarm contact threshold <21.6 Vdc <43.2 Vdc <64.8 Vdc
Parallel connection possible possible possible
possible with external ORing already fitted with already fitted with
Redundant parallel connection
diode internal ORing diode internal ORing diode
GENERAL TECHNICAL DATA
Efficiency (Uin 400 / 500 Vac) >92% / >92% >92% / >92% >94% / >94%
Dissipated power (Uin 400 / 500 Vac) 80 W / 80 W 80 W / 80 W 60 W / 60 W
Operating temperature range –20...+60°C, with derating over 45°C / thermal protection (3)
Input/output isolation 3 kVac / 60 s SELV output (5)
Input/PE isolation 2 kVac / 60 s
Output/PE isolation 0.5 kVac / 60 s
Safety standards EN 60950-1+A1+A2+A12, UL 508
Electromagnetic compatibility EN61000-6-1, EN61000-6-2, EN61000-6-3, EN61000-6-4
MTBF at 25°C and nominal ratings >500'000 h according to SN 29500 / >150'000 h according to MIL Std. HDBK 217F
Overvoltage category / Pollution degree II / 2
Protection degree IP 20 IEC 529, EN60529
Connection type 6 mm² fixed screw terminal blocks
Housing material aluminium
Approximate weight 1.2 kg
Mounting information vertical on rail, allow 10 mm spacing between adjacent components
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 —

36
3-phase switching power
supply 400-500 Vac - output
power 2400 W 130
• 3-phase input 340…550 Vac
• Short circuit, overload, over temperature and overvoltage input
and output protection
• Elevated outrush current to ensure the selectivity of protections
and start-up of heavy loads 234 105
• High efficiency and low consumption
• Suitable for SELV and PELV circuits
E203601

NOTES BLOCK DIAGRAM


The depth measurement includes rail clamp clearance. 
            
(2) Version made to order (not kept in stock); contact our sales
office for availability.    

(3) Over 45°C apply a derating equal to approximately 40 W/°C





   

(4) For this peak of power, the output voltage does not decrease 
   
more than 10% of the rated value, however the value of the
current supplied by the power supply also depends on the  

line resistance.     ­

  € ‚     „ …  


ƒ   … 

VERSIONS Code XCSG2401C Code XCSG2401D APPLICATIONS


Output 12-15-24 Vdc 100 A redundant version CSG2401C (2) Series CSG2401 has an internal microprocessor that controls
Output 24-48 Vdc 50 A redundant version CSG2401D (2) the many functions of the power supply, which can be
programmed thanks to a user-friendly menu activated by 4
buttons on the front and shown on the front display.
INPUT TECHNICAL DATA Front display: during normal operation, this shows the
Input rated voltage 3x 400–500 Vac (range 340…550 Vac) output voltage value and current used by the load; during
Frequency 47...63 Hz programming, it allows for the choice of the various functions
Current with nominal lout (Uin 400 / 500 Vac) 4.2 A / 3.5 A available.
Input protection: the input circuit has been designed to
Inrush peak current < 2 A (with active limitation circuit)
avoid the most common problems seen in 3-phase networks.
Power factor > 0.92
It therefore has:
Internal protection fuse —
1) a PFC circuit failure (latched shutdown) circuit
External protection on AC line circuit breaker 3x 10 A characteristic C - fuses: 3x T 10 A 2) a system for controlling lack of phase that automatically
OUTPUT TECHNICAL DATA reduces output power
Output rated voltage 12-15-24 Vdc 24-48 Vdc 3) an auto-restart switch-off system in the event of overvoltage
Output adjustable range 11.5…29 Vdc 23...56 Vdc and undervoltage
Continuous current 100 A at 45°C (3) 50 A at 45°C (3) Output protection: limit current can be selected as between
Overload limiting current 150 A for >5 s with Uout >90% 75 A for >5 s with Uout >90% 10% and 100% of rated current; protection type against
Un (4) Un (4) overload and short circuit can be chosen from:
Short circuit peak current >150 A for 5 s (4) >75 A for 5 s (4) 1) Hiccup auto reset with limit current, equal to 150% of rated
Load regulation < 1% < 1% current and ON/OFF time can be altered;
Ripple at nominal ratings ≤ 200 mVpp ≤ 200 mVpp 2)constant power
Hold up time (Uin 400 / 500 Vac) >10 ms / >10 ms >10 ms / >10 ms Output signals: in addition to the "DC OK” and “FAULT”
Overload / short circuit protections programmable (see side) LEDs, the device also has:
Status display Green "DC OK" LED / "DC OK” failure contact / Red “Overload” LED / 1) an analogue signal 0...10V or 4...20mA that provides an
LCD display (see side) indication of current used by the load
Alarm contact threshold programmable 2) a programmable alarm contact able to signal and record
Parallel connection possible the exceeding of the various limits to a memory: output
Redundant parallel connection possible voltage, input current, output overload, over temperature
and other parameters that can be defined by programming.
GENERAL TECHNICAL DATA Additional functions:
Efficiency (Uin 400 / 500 Vac) >92% / >92% >93% / >93% 1) Battery charger: the acid lead battery charging function
Dissipated power (Uin 400 / 500 Vac) 200 W / 200 W 180 W / 180 W can be selected;
Operating temperature range –20...+60°C, with derating over 45°C / thermal protection (3) 2) Remote sensing (sense): this allows for the monitoring and
Input/output isolation 3 kVac / 60 s SELV output (5) compensation of voltage drops on long power supply lines
Input/PE isolation 1.5 kVac / 60 s 3) The power supply can be switched off and disabled from
Output/PE isolation 0.5 kVac / 60 s a remote position
Safety standards EN 60950-1+A11, UL 508 4) Auxiliary voltage: auxiliary 12 Vdc is also available,
Electromagnetic compatibility EN61000-6-2, EN61000-6-4 regardless of the main output voltage status
MTBF at 25°C and nominal ratings >500'000 h according to SN 29500 / >150'000 h according to MIL Std. HDBK 217F 5) Temperature control: by connecting an external sensor
Overvoltage category / Pollution degree II / 2 (NTC), the battery charge temperature can be controlled.
Protection degree IP 20 IEC529, EN60529 6) Communication port: by means of an RS232 communication
Connection type screw-clamp terminal blocks 4 and 6 mm² device the power supply can be piloted and monitored from
Housing material aluminium a remote position.
Approximate weight 2.8 Kg
Mounting information vertical on rail, allow 60 mm spacing between adjacent components
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 —

37
3-phase switching power
supply 400-500 Vac - output
power 2400 W 130
• 3-phase input 340…550 Vac
• Short circuit, overload, over temperature and overvoltage input
and output protection
• Elevated outrush current to ensure the selectivity of protections
and start-up of heavy loads 234 105
• High efficiency and low consumption
• Suitable for PELV circuits
E203601

NOTES BLOCK DIAGRAM


The depth measurement includes rail clamp clearance. 
            
With DC input, outrush current is reduced by 30%
(2) Version made to order (not kept in stock); contact our sales    

office for availability.





   

(3) Over 45°C apply a derating equal to approximately 40 W/°C 


   
(4) For this peak of power, the output voltage does not decrease
more than 10% of the rated value, however the value of the  

current supplied by the power supply also depends on the     ­

line resistance.   € ‚     „ …  


ƒ   … 
(5) G and R versions not suitable for SELV applications

VERSIONS Code XCSG2401G Code XCSG2401R APPLICATIONS


Output 72 Vdc 33 A redundant version (5) CSG2401G (5) (2) Series CSG2401 has an internal microprocessor that controls
Output 100-110-170 Vdc 14 A redundant version (5) CSG2401R (5) (2) the many functions of the power supply, which can be
programmed thanks to a user-friendly menu activated by 4
buttons on the front and shown on the front display.
INPUT TECHNICAL DATA Front display: during normal operation, this shows the
Input rated voltage 3x 400–500 Vac (range 340…550 Vac) output voltage value and current used by the load; during
Frequency 47...63 Hz programming, it allows for the choice of the various functions
Current with nominal lout (Uin 400 / 500 Vac) 4.2 A / 3.5 A available.
Inrush peak current < 2 A (with active limitation circuit) Input protection: the input circuit has been designed to
Power factor > 0.92 avoid the most common problems seen in 3-phase networks.
It therefore has:
Internal protection fuse —
1) a PFC circuit failure (latched shutdown) circuit
External protection on AC line circuit breaker 3x 10 A characteristic C - fuses: 3x T 10 A
2) a system for controlling lack of phase that automatically
OUTPUT TECHNICAL DATA reduces output power
Output rated voltage 72 Vdc 100-110-170 Vdc 3) an auto-restart switch-off system in the event of overvoltage
Output adjustable range 50...87 Vdc 88...175 Vdc and undervoltage
Continuous current 33 A at 45°C (3) 14 A at 45°C (3) Output protection: limit current can be selected as between
Overload limiting current 50 A for >5 s with Uout >90% 21 A for >5 s with Uout>90% 10% and 100% of rated current; protection type against
Un (4) Un (4) overload and short circuit can be chosen from:
Short circuit peak current >50 A for 5 s (4) >21 A for 5 s (4) 1) hiccup auto reset with limit current, equal to 150% of rated
Load regulation < 1% < 1% current and ON/OFF time can be altered;
Ripple at nominal ratings ≤ 200 mVpp ≤ 200 mVpp 2) Constant power
Hold up time (Uin 400 / 500 Vac) >10 ms / >10 ms >10 ms / >10 ms Output signals: in addition to the "DC OK” and “FAULT”
Overload / short circuit protections programmable (see side) LEDs, the device also has:
Status display Green "DC OK" LED / "DC OK” failure contact / Red “Overload” LED / 1) an analogue signal 0...10V or 4...20mA that provides an
LCD display (see side) indication of current used by the load
Alarm contact threshold programmable 2) a programmable alarm contact able to signal and record
Parallel connection possible the exceeding of the various limits to a memory: output
Redundant parallel connection possible voltage, input current, output overload, over temperature
and other parameters that can be defined by programming.
GENERAL TECHNICAL DATA Additional functions:
Efficiency (Uin 400 / 500 Vac) >92% / >92% >92% / >92% 1) Battery charger: the acid lead battery charging function
Dissipated power (Uin 400 / 500 Vac) 200 W / 200 W 200 W / 200 W can be selected;
Operating temperature range –20...+60°C, with derating over 45°C / thermal protection (3) 2) Remote sensing (sense): this allows for the monitoring and
Input/output isolation 3 kVac / 60 s SELV output (5) compensation of voltage drops on long power supply lines
Input/PE isolation 1.5 kVac / 60 s 3) The power supply can be switched off and disabled from
Output/PE isolation 0.5 kVac / 60 s a remote position
Safety standards EN 60950-1+A11, UL 508 4) Auxiliary voltage: auxiliary 12 Vdc is also available,
Electromagnetic compatibility EN61000-6-2, EN61000-6-4 regardless of the main output voltage status
MTBF at 25°C and nominal ratings >500'000 h according to SN 29500 / >150'000 h according to MIL Std. HDBK 217F 5) Temperature control: by connecting an external sensor
Overvoltage category / Pollution degree II / 2 (NTC), the battery charge temperature can be controlled.
Protection degree IP 20 IEC529, EN60529 6) Communication port: by means of an RS232 communication
Connection type screw-clamp terminal blocks 4 and 6 mm² device the power supply can be piloted and monitored from
Housing material aluminium a remote position.
Approximate weight 2.8 Kg
Mounting information vertical on rail, allow 60 mm spacing between adjacent components
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 —

38
DC/DC Insulated converters
output power 120 W
• D C wide range input
115
• S hort-circuit, overload, overtemperature protection
• E xtremely small size

128

39

NOTES BLOCK DIAGRAM


The depth measurement includes terminal block and rail clamp
clearance.
(1) Inrush current measured at Un with battery power supply;
peak current varies according to the internal impedance of
the current source and the resistance of the connections.
(2) The capacitors between phase and neutral, requires that
the isolation tests are carried out in DC in accordance with
EN60950.
(3) V ersion made to order (not kept in stock); contact our
sales office for availability.

VERSIONS Code XCSA120BC Code XCSA120CB Code XCSA120CC Code XCSA120DC


12 Vdc / 24 Vdc 5 A CSA120BC (3)
24 Vdc / 12 Vdc 7 A CSA120CB
24 Vdc / 24 Vdc 5 A CSA120CC
48 Vdc / 24 Vdc 5 A CSA120DC
INPUT TECHNICAL DATA
Input rated voltage 12 Vdc (range 10.5…18 Vdc) 24 Vdc (range 18…36 Vdc) 24 Vdc (range 18…36 Vdc) 48 Vdc (range 36…72 Vdc)
Current with nominal lout 10 A ± 10% 5.1 A ±10% 5.8 A ±10% 2.8 A ±10%
Inrush peak current < 60A / < 2ms (1) < 110A / < 2ms (1) < 90A /< 2ms (1) < 120A / < 2ms (1)
Power in standby <1.5 W at 12 Vdc <1 W at 24 Vdc <1.5 W at 24 Vdc <2 W at 48 Vdc
Internal protection fuse Replaceable T 20 A Replaceable T 10 A Replaceable T 5 A
External protection on AC line ≥25 A characteristic C ≥13 A characteristic C ≥6 A characteristic C
Surge protection circuit varistor and automatic power off varistor and automatic switch-off at 38 Vdc varistor and automatic switch-off
at 19 Vdc at 76 Vdc
OUTPUT TECHNICAL DATA
Output rated voltage 24 Vdc 12...15 Vdc 24 Vdc 24 Vdc
Output adjustable range 22.5...27.5 Vdc 12...15 Vdc 22.5...27.5 Vdc 22.5...27.5 Vdc
Continuous current 5 A at 24 Vdc 7 A at 12 Vdc 5 A at 24 Vdc 5A at 24 Vdc
Overload limiting current 6.5 A 9.1 A 6.5 A 6.5 A
Short circuit peak current 12 A for 300 ms 15 A for 300 ms 12 A for 300 ms 13 A for 300 ms
Load regulation <0.5% <0.5% <0.5% <0.5%
Ripple at nominal ratings ≤ 100 mVpp ≤ 100 mVpp ≤ 150 mVpp ≤ 200 mVpp
Hold Up time at In >1 ms >2 ms 4.5 ms
Overload / short circuit protections hiccup at the overload limit with auto reset/thermal protection
Status display Green LED "DC OK"
Alarm contact threshold —
Parallel connection possible
Redundant parallel connection possible with external ORing diode
GENERAL TECHNICAL DATA
Efficiency (Uin 110 Vdc) > 83% >85% >87% >90%
Dissipated power (Uin 110 Vdc) <25 W <17 W <18 W <13 W
Operating temperature range -20...+50°C
Input/output isolation 2.1 kVdc / 60s (2)
Input/PE isolation 1.41 kVdc / 60s (2)
Output/PE isolation 0.75 kVdc / 60s (2)
Safety standards EN 60950-1+A1+A2+A12, UL 508
Electromagnetic compatibility EN61000-6-1, EN61000-6-2, EN61000-6-3, EN61000-6-4
MTBF at 25°C and nominal ratings >500'000 h according to SN 29500 / >150'000 h according to MIL Std. HDBK 217F
Overvoltage category / Pollution degree II / 2
Protection degree IP 20 IEC 529, EN60529
Connection type 2.5 mm² removable screw terminal blocks
Housing material aluminium
Approximate weight 550 g
Mounting information vertical on rail, allow 10 mm spacing between adjacent components
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 —

39
DC/DC Insulated converters
output power 240 W
• D C wide range input
140
• S hort-circuit, overload, overtemperature protection
• Internal diode for the redundant parallel connection NOTE:
• E xtremely small size CSD, CSF30, CSF85 and CSF120 series power supplies
can also be powered at 110 Vdc.

135

63.5

NOTES BLOCK DIAGRAM


The depth measurement includes terminal block and rail clamp
clearance.
(1) Inrush current measured at Un with battery power supply;
peak current varies according to the internal impedance of
the current source and the resistance of the connections.
(2) Over 50°C apply a derating -6 W/°C, max 60°C
(3)The capacitors between phase and neutral, requires that
the isolation tests are carried out in DC in accordance with
EN60950.

VERSIONS Code XCSA240FC


110 Vdc / 24 Vdc 10 A —
110 Vdc / 24 Vdc 10 A redundant CSA240FC

INPUT TECHNICAL DATA


Input rated voltage 110 Vdc (range 100...130 Vdc)
Current with nominal lout 2.4 A ±10%
Inrush peak current < 150A / < 2ms (1)
Power in standby <3.4 W at 110 Vdc
Internal protection fuse Replaceable T 5 A
External protection on AC line ≥6 A characteristic C
Surge protection circuit varistor and automatic switch-off
at 136 Vdc
OUTPUT TECHNICAL DATA
Output rated voltage 24 Vdc
Output adjustable range 22.7…27 Vdc
Continuous current 10 A at 50°C (2)
Overload limiting current 15 A
Short circuit peak current 21 A for 300 ms
Load regulation <1.5%
Ripple at nominal ratings ≤ 100 mVpp
Hold up time at In (Uin 110 Vdc) >4 ms
Overload / short circuit protections hiccup at the overload limit with auto reset/thermal protection
Status display Green LED "DC OK" / failure contact "DC OK" / Red LED "Overload"
Alarm contact threshold —
Parallel connection possible
already fitted with internal ORing
Redundant parallel connection
diode
GENERAL TECHNICAL DATA
Efficiency (Uin 110 Vdc) >89%
Dissipated power (Uin 110 Vdc) <28 W
Operating temperature range –20...+60°C, with derating over 50°C (2)
Input/output isolation 2.1 kVdc / 60s (3)
Input/PE isolation 1.41 kVdc / 60s (3)
Output/PE isolation 0.75 kVdc / 60s (3)
Safety standards EN 60950-1+A1+A2+A12
Electromagnetic compatibility EN61000-6-2, EN61000-6-4
MTBF at 25°C and nominal ratings >500'000 h according to SN 29500 / >150'000 h according to MIL Std. HDBK 217F
Overvoltage category / Pollution degree II / 2
Protection degree IP 20 IEC 529, EN60529
Connection type 2.5 mm² removable screw terminal blocks
Housing material aluminium
Approximate weight 800 g
Mounting information vertical on rail, allow 10 mm spacing between adjacent components
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 —

40
Adjustable stabilised linear
power supply 24 Vac
• 1 .2...24 Vdc adjustable output voltage
• 1 .5 and 5 A output current 130 118
• S hort-circuit, overload, overtemperature protection

43 37
74 115

NOTES BLOCK DIAGRAM


The depth measurement includes terminal block and rail clamp
clearance.
(1) See applications.

VERSIONS Code XCL1R Code XCL5R APPLICATIONS


Output 1.2 A CL1R Cabur CL-R series power supplies
Output 5 A CL5R are linear stabilised with adjust-
able output, capable of satisfying all
INPUT TECHNICAL DATA small load power needs with non-
Input rated voltage 9…26 Vac (see Table 1) standard voltages at an extremely
Frequency 50...60 Hz affordable cost.
Current with nominal lout 2.5 A 6A They can be rail mounted in any
Internal protection fuse Replaceable T 3 A Replaceable T 10 A position as long as sufficient space
External protection on AC line MCB: 4 A characteristic C - fuse T 4 A MCB: 10 A characteristic C - T 10 A fuse is left for the free circulation of air
for cooling, while model CL1R has a
OUTPUT TECHNICAL DATA degree of protection IP00, meaning
Output rated voltage 1.2...24 Vdc 1.2...24 Vdc it is to be used inside a protected
Output adjustable range (see Table 1 and Table 2) (see Table 1 and Table 2) container.
Continuous current 0.3...1.5 A (see Table 2) 0.8...5 A (see Table 2) Even where the power supply is
Overload limiting current — — protected against overcurrents, it is
Load regulation < 1% advised to follow the nominal data
Ripple at nominal ratings < 50 mVpp at 24 Vac indicated in the tables below.
Hold Up time at In >20 ms
Overload / short circuit protections at constant current, limit current, with automatic recovery/thermal protection (1) CL1R and CL5R provide the
Status display Green LED "DC OK" nominal performances if combined
with the secondary voltages indi-
GENERAL TECHNICAL DATA cated in Tab. 1; with a secondary
Operating temperature range –20...+45°C / thermal protection (1) voltage of 24...27 Vac, the maxi-
Input/output isolation not insulated mum obtainable current at output
Input/PE isolation 0.5 kVac / 60 s voltages adjusted to values below
Output/PE isolation 0.5 kVac / 60 s 24 Vdc is indicated in Tab.  2;
Reference Standards IEC 664-1, DIN VDE to stabilise the output voltage and
Electromagnetic compatibility EN50081-1, EN61000-6-4 reduce ripple at full load, linear
MTBF at 25°C and nominal ratings >500'000 h according to SN 29500 / >150'000 h according to MIL Std. HDBK 217F power supplies must be powered
Overvoltage category / Pollution degree II / 2 with an input voltage that exceeds
Protection degree IP 00 IEC 529, EN60529 the output voltage, whereas if they
Connection type 2.5 mm² fixed screw terminal blocks are powered at 24 Vac, with an
Housing material UL94V-0 plastic aluminium output adjusted to 24 Vdc and
Approximate weight 120 g 350 g maximum current absorption, the
Mounting information vertical on rail, allow 20 mm spacing between adjacent components ripple increases and the stability
of the output voltage to load varia-
MOUNTING ACCESSORIES tions and ±10% network variations
drops; voltages above 27 Vac cause
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
significant heating, triggering the
Mounting rail type according to IEC60715/G32 PR/DIN/AC, PR/DIN/AS, PR/DIN/AL —
thermal protection and reducing the
current supplied.
Products are supplied with a de-
INPUT Uout max Iout max (A) Iout max (A) INPUT Uout max Iout max (A) Iout max (A) fault voltage of 24 Vdc at the output
(Vac) (Vdc) XCL1R XCL5R (Vac) (Vdc) XCL1R XCL5R and 26 Vac at the input.
24...27 24 1.5 5 24 24 1.5 5
16...18 15 1.5 5 24 15 0.8 2.5
14...16 12 1.5 5 24 12 0.7 2
12...14 10 1.5 5 24 10 0.5 1.5
12 9 1.5 5 24 9 0.45 1.3
9 5 1.5 5 24 5 0.3 0.8

Table 1 (see explanation to the side) Table 2 (see side explanation)

41
Filtered power supply
without transformer
and with non-stabilised output
93
• R ail mounting
• F or correcting voltages from 6 Vac to 20 Vac
•O  utput 1.41 times the input voltage

70
80

NOTES BLOCK DIAGRAM


(2) Version made to order (not kept in stock); for information
contact our sales office.
(3) Capable of operating with an input voltage of 6 Vac min.
to 30 Vac max.; output voltage is not stabilised and varies
depending on the load and on variations in the input voltage
supplied by the transformer.
(4) Protected from overcurrent with integrated input fuse (except
AR1); it is advisable to protect the output line wires with fuses
sized according to the load and wire currents.

VERSIONS Code XAR6 APPLICATIONS


Output 6 A AR6 The rectified and filtered power
supply comprises a transformer
INPUT TECHNICAL DATA which isolates and reduces the
Input rated voltage 6…20 Vac secondary voltage from the net-
Frequency 50...60 Hz work voltage (not supplied), a
Current with nominal lout 7.2 A at 20 Vac bridge rectifier and a filter capac-
Internal protection fuse Replaceable T 8 A ity that convert alternating voltage
External protection on AC line MCB: 10 A characteristic C - T 10 A fuse into direct voltage at an SELV
value of less than 60 Vdc.
OUTPUT TECHNICAL DATA The power supply is not stabilised,
Output voltage (without load) Uout = (Uin x 1.41) (3) therefore the output voltage varies
Output voltage (at full load) Uout = (Uin x 1.41) -2 (3) according to the power consumed
Continuous current 6 A at 20°C by the load and to network voltage
Overload limiting current 9A fluctuations of ±10%. The formu-
Load regulation — lae described in the output techni-
Ripple at nominal ratings ≤ 10% cal data are used to calculate volt-
Hold Up time at In >20 ms age at no load, 50% load and full
Overload / short circuit protections not supplied, insert external fuse (4) load and to select the transformer
Status display Green LED "DC OK" best suited to your needs. These
Parallel connection — power supplies are a reliable
Redundant parallel connection — and affordable source for
powering relays, contactors,
GENERAL TECHNICAL DATA solenoid valves and loads capa-
Operating temperature range –20...+45°C / max 60°C ble of operating smoothly with a
Input/output isolation not insulated relatively high (5%) alternating
Input/PE isolation 0.5 kVac / 60 s waste on 24 Vdc (ripple) and
Output/PE isolation 0.5 kVac / 60 s strong changes in output voltage,
Reference Standards IEC 664-1, DIN VDE whereas in applications in which
MTBF at 25°C and nominal ratings >500'000 h according to SN 29500 / >150'000 h according to MIL Std. HDBK 217F the network is highly unstable and
Overvoltage category / Pollution degree II / 2 prone to voltage dips, they may
Protection degree IP 00 IEC 529, EN60529 not be suitable for powering
Connection type 2.5 mm² fixed screw terminal blocks devices with microprocessors
Housing material UL94V-0 plastic and memories, analogue con-
Approximate weight 140 g verters or devices that require
Mounting information vertical on rail, allow 50 mm spacing between adjacent components a highly stable power supply
MOUNTING ACCESSORIES voltage.
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 PR/DIN/AC, PR/DIN/AS, PR/DIN/AL

INPUT OUTPUT OUTPUT


(Vac) without load (Vdc) full load (Vdc)
20 28.7 24.2
18 25.4 21.4
15 21.2 17.2
12 17 15
9 12.7 8.7
6 8.5 4.5

42
Accessory for charging
buffer batteries
• B attery charging
• P arallel connection of power supplies 93
• S uitable for power supplies up to 10 A
• L ine and battery safety fuses
• F lyback diode
• L oad current limiting resistor 26
80

NOTES BLOCK DIAGRAM


The depth measurement includes rail clamp clearance.
(1) The load current may vary depending on the battery type and
its charge status:
- approx. 0.5A max at 12Vdc
- approx. 1A max at 24Vdc
OUTPUT
(2) The device does not prevent deep discharge of the battery, Max 15A
which occurs when a voltage of 0 to 60% of the nominal
voltage is read at its terminals; deep discharge drastically
reduces the life of the battery.

VERSIONS Code XCSBC APPLICATIONS


CSBC 1. Battery charger
This module enables Cabur power
supplies to charge a battery while
GENERAL TECHNICAL DATA simultaneously powering the load.
Power supply input voltage 6...30 Vdc The diodes effectively block the
Power supply nominal current >3A power supply from the battery,
Nominal load voltage 6...29.5 Vdc the resistor limits the load current
Maximum load current 10 A to prevent power supply safety
Charging current (1) cut-off and prolonging the life of
Battery disconnection voltage function not present the battery, and fuse F1 protects
the battery in the event of a short-
IN/OUT voltage drop 0.5 V
circuit on the load.
Battery safety fuse F1 = T 6.3 A / F2 = T 1 A
The connection occurs as shown
Protections short-circuit / battery overload (2)
below.
Alarm signal —
Operating temperature range –10...+50°C 2. Placing power supplies in par-
Reference Standards IEC 664-1, DIN VDE allel
Overvoltage category / Pollution degree II / 2 This module can be used to put
Protection degree IP 20 IEC 529, EN60529 two power supplies without a
Connection type 2.5 mm² fixed screw terminal blocks blocking diode in parallel, elimi-
Housing material UL94V-0 plastic nating the need for fuse F2 in
Approximate weight 80 g series with the charging current
Mounting information vertical on rail, side by side limiting resistor.
MOUNTING ACCESSORIES The connection occurs as shown
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB below.
Mounting rail type according to IEC60715/G32 PR/DIN/AC, PR/DIN/AS, PR/DIN/AL

1. Battery charger 2. Placing power supplies in parallel

L AC + + + L AC + + +
GND (A) – + (A) – +
(C)
CSBC GND (C)
CSBC
+ – + –
N AC – – – N AC – – –
IN OUT IN OUT
+ AC +
(B)
BATTERY GND (A)

AC –
(A) Power supply
(C) CSBC

(A) Power supply


(B) Battery
(C) CSBC

43
Accessory for charging
and checking buffer batteries
• S uitable for power supplies with adjustable output
115
• S uitable for lead batteries
• S upplies power to load and battery simultaneously
• B attery safety fuse Item available until supplies last; will be
• B attery full discharge protection 130 replaced by XCSU240S
• L ED status indicator and alarm relay 55

NOTES BLOCK DIAGRAM


The depth measurement includes rail clamp clearance.
(A) = Power supply
(B) = Battery
OUTPUT
(C) = CS-UPS Max 10A

VERSIONS Code XCSUPS1 Code XCSUPS2 APPLICATIONS


Output 24 Vdc CS-UPS1 All power supplies with adjustable out-
Output 12 Vdc CS-UPS2 put to at least +15% of the nominal
voltage can be used for charging lead
GENERAL TECHNICAL DATA acid batteries to be used as back-up
Power supply input voltage 26...28.5 Vdc 12...15 Vdc power, offering regulation and control
Power supply nominal current ≥3A ≥3A in the event of a blackout or local net-
Nominal load voltage 26...28 Vdc 10...15 Vdc work failure. The circuit in the CS-UPS1
Maximum load current 10 A 10 A module regulates and controls battery
Charging current Selectable 2 A or 4 A Selectable 2 A or 4 A charging current and can be set to two
Battery disconnection voltage ≤ 18 Vdc ±0.5V ≤ 9.2 Vdc ±0.5V maximum charging currents: 2 A or 4
A; it also disconnects the load from the
IN/OUT voltage drop 0.4 V
battery if the voltage at full load drops
Battery safety fuse T 15 A 42 V blade type
below the limit to prevent deep battery
Protections Reverse polarity, short-circuit, battery overload, battery deep discharge
discharge, which occurs when a voltage
Alarm signals Power supply OK: SPDT 24 V / 1 A of 0 to 60% of the nominal voltage is
 Battery OK Green LED read at its terminals; deep discharge
 Battery LOW Red LED drastically reduces the life of the battery.
 Load OK Yellow LED The module is also equipped with a fuse
 Green LED Green LED that protects the battery and connecting
Operating temperature range –10...+50°C
wires to the overcurrent module. The
Reference Standards IEC 664-1, DIN VDE following alarm indicators are available:
Overvoltage category / Pollution degree II / 2 PS OK: Green LED, indicates that the
Protection degree IP 20 IEC 529, EN60529 network power supply is operational and
Connection type 2.5 mm² removable screw terminal blocks is powering the load, while the battery is
Housing material aluminium kept charged.
Approximate weight 300 g LOAD OK: Yellow LED, indicates that
Mounting information vertical on rail, side by side the CS-UPS terminal blocks are show-
MOUNTING ACCESSORIES ing a power that is capable of supplying
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB the load.
Mounting rail type according to IEC60715/G32 — BATT. OK: Green LED, with the power
supply switched off or disconnected,
indicates that the battery is connected
and is charging.
BATT. LOW: Red LED, indicates that the
battery is discharged.
REVERSE BATTERY: Red LED, indi-
cates that the battery is connected with
reversed polarity.
Failure contact: this is a single
exchange 1 A / 24 V relay which is
triggered when the power to the load
switches from the power supply to the
battery. The remote warning indicates
the system status even when the power
supply switches off due to an internal
panel malfunction and indicates that the
battery was activated due to a local fault
not immediately visible to the operator,
unlike a general blackout.

44
Accessory for charging
and checking buffer
batteries
88
• Power supply connection, supplies energy to the load and maintains
the backup battery
• Suitable for Lead-Acid, NiMH and Ni-Cd batteries
• 12 V or 24 V battery voltages with a load current of up to 5 A
• High efficiency and low consumption 63
• Small size 70

NOTES BLOCK DIAGRAM


(1) Programmable

VERSIONS Code XCSU120S APPLICATIONS


CSU120S XCSU120S is a smart battery equipped with a microproces-
sor to determine the most appropriate charging and monitoring
INPUT TECHNICAL DATA algorithm to ensure battery efficiency. Using an external DC
Power supply input voltage 12-24 Vdc (range 10…16 Vdc / 20…29 Vdc) power source, XCSU120S is able to charge universal and NiCd,
Maximum input current 5A NiMh and lead acid batteries.
OUTPUT TECHNICAL DATA PRODUCT FEATURES:
Load voltage 12-24 Vdc (1) •Independent 12 or 24 V input, output and battery voltages
Load current 5A max. to 20°C / 4A max. to 45°C (microprocessor sets the voltage to the required level)
Status display Normal operation failure contact (Ready) • It is no longer necessary to increase the voltage of the power
Battery operation failure contact (Backup) supply to allow the battery to charge, resulting in an increase
Green LED "DC OK" of the output voltage
Battery charge yellow LED / Battery supplies the charge • The device is supplied with a default setting that can be
Communication RS485 - ModBus RTU changed with a simple ModBus connection, which can also
TECHNICAL DATA BATTERIES be used to monitor functions and establish a direct connec-
Battery type Lead-Acid, NiMH, Ni-Cd tion to a PLC
Battery nominal voltage 12 or 24 Vdc (1) • Integrated software allows you to select battery type and
Maximum load current 500 mA (1) capacity, with the microprocessor selecting the most appropri-
Nominal capacity range 1.2 ...10Ah ate charging algorithm and monitoring its efficiency
Backup lag time n/a • System monitoring with two available remote alarms that can
Protections reverse polarity/overload/deep discharge be set to no network power, battery on, battery efficiency,
battery overtemperature, output overload
GENERAL TECHNICAL DATA • Programmable remote control for turning battery charging,
Efficiency >90% output and alarms on/off
Dissipated power < 2W • Programmable on/off timer
Operating temperature range -20...+60°C • DIP-switch programming for most functions
Input/output isolation -
Input/PE isolation -
Output/PE isolation -
Safety standards EN60950
Electromagnetic compatibility EN61000-6-2, EN61000-6-4
MTBF at 25°C and nominal ratings >500'000 h according to SN 29500 / >150'000 h according to MIL Std.
HDBK 217F
Overvoltage category / Pollution degree II / 2
Protection degree IP 20 IEC 529, EN60529
Connection type 2.5 mm² screw-clamp terminal blocks
Housing material aluminium
Approximate weight 200 g
Mounting information vertical on rail, allow 5 mm spacing between adjacent components
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 —

45
Accessory for charging
and checking buffer
batteries
115
• Power supply connection, supplies energy to the load and maintains
the backup battery
• Suitable for Lead-Acid, NiMH and Ni-Cd batteries
• 12 V or 24 V battery voltages with a load current of up to 10 A
• High efficiency and low consumption
130
• Small size
40

NOTES BLOCK DIAGRAM


(1) Programmable

VERSIONS Code XCSU240S APPLICATIONS


CSU240S XCSU240S is a smart battery equipped with a microproces-
sor to determine the most appropriate charging and monitoring
INPUT TECHNICAL DATA algorithm to ensure battery efficiency. Using an external DC
Power supply input voltage 12-24 Vdc (range 11... 30 Vdc) power source, XCSU240S is able to charge NiCd, NiMh and
Maximum input current 10 A lead acid batteries.
OUTPUT TECHNICAL DATA PRODUCT FEATURES:
Load voltage 12-24 Vdc (1) • Independent 12 or 24 V input, output and battery voltages
Load current 10A max at 20°C / 9A max at 45°C (microprocessor sets the voltage to the required level)
Status display Normal operation failure contact (Ready) • It is no longer necessary to increase the voltage of the power
Battery operation failure contact (Backup) supply to allow the battery to charge, resulting in an increase
Green LED "DC OK" of the output voltage
Battery charge yellow LED / Battery supplies the charge • The device is supplied with a default setting that can be
Communication RS485 - ModBus RTU changed with a simple ModBus connection, which can also
TECHNICAL DATA BATTERIES be used to monitor functions and establish a direct connec-
Battery type Lead-Acid, NiMH, Ni-Cd tion to a PLC
Battery nominal voltage 12 or 24 Vdc (1) • Integrated software allows you to select battery type and
Maximum load current 1 A (1) capacity, with the microprocessor selecting the most appropri-
Nominal capacity range 1.2… 20Ah ate charging algorithm and monitoring its efficiency
Backup lag time n/a • System monitoring with two available remote alarms that can
Protections reverse polarity/overload/deep discharge be set to no network power, battery on, battery efficiency,
battery overtemperature, output overload
GENERAL TECHNICAL DATA • Programmable remote control for turning battery charging,
Efficiency >90% output and alarms on/off
Dissipated power < 3W • Programmable on/off timer
Operating temperature range -20... +60°C
Input/output isolation -
Input/PE isolation -
Output/PE isolation -
Safety standards EN60950
Electromagnetic compatibility EN61000-6-2, EN61000-6-4
MTBF at 25°C and nominal ratings >500'000 h according to SN 29500 / >150'000 h according to MIL Std.
HDBK 217F
Overvoltage category / Pollution degree II / 2
Protection degree IP 20 IEC 529, EN60529
Connection type 2.5 mm² (IN/OUT/BATT) and 0.75 mm² (signal) removable screw terminal
blocks
Housing material aluminium
Approximate weight 300 g
Mounting information vertical on rail, allow 5 mm spacing between adjacent components
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 —

46
Switching power supply with
integrated battery charging
• For powering loads and maintaining battery charge
• Suitable for lead batteries 115
• Supplies power to load and battery simultaneously
• Battery safety circuit
• Battery full discharge protection
• LED status indicator and alarm relay

130
40

NOTES BLOCK DIAGRAM


The depth measurement includes terminal block and rail clamp
clearance.
(2) With an input powered at 100...127 Vdc, using constant
power and Ta> 45°C, the outrush current is reduced by 25%
BATT.
(3) In addition to powering the load, the power supply delivers
around 0.8 A for charging the battery
(4) Over 50°C apply a derating -0.13 A/°C, max 60°C
not available

DC PSU OK

VERSIONS Code XCSC120B Code XCSC120C APPLICATIONS


Output 12 Vdc 5 A CSC120B
Output 24 Vdc 5 A CSC120C

INPUT TECHNICAL DATA


Input rated voltage 120–230 Vac (range 90…264 Vac / 100…370 Vdc) (2)
Frequency 47...63 Hz
Current with nominal lout (Uin 120 / 230 Vac) 1.6 / 0.9 A 1.9 /1.1 A
Inrush peak current < 20 A
Power factor > 0.6
Internal protection fuse Replaceable T 3.15 A
External protection on AC line circuit breaker 4 A characteristic C - fuses: T 3.15 A
OUTPUT TECHNICAL DATA
Output voltage with power supply on 12.5…15.5 Vdc 23…27.5 Vdc
Output voltage with battery operation 12…14.4 Vdc 24…26.2 Vdc
Continuous current 5 A at 50°C (3) 5 A at 50°C (3)
Overload limiting current >11 A for >30 s >8 A for >30 s
Short circuit peak current >18 A for >50 ms >12 A for >50 ms
Load regulation < 1% < 1%
Ripple at nominal ratings 80 mVpp 80 mVpp
Hold up time at In (Uin 120 / 230 Vac) >24 ms / >80 ms >17 ms / >72 ms
Overload / short circuit protections with power supply on: hiccup at limit current with automatic recovery
with power supply off: self-resetting electronic fuse in case of battery short-circuit
with power supply off: threshold relay to protect against deep battery discharge
Alarm signal Green LED "PSU OK" / failure contact / Red LED "BATTERY"
Max load current 0.8 A (suitable for sealed lead acid batteries up to 15 Ah)
GENERAL TECHNICAL DATA
Efficiency (Uin 120 / 230 Vac) >81% / >83% >84% / >86%
Dissipated power (Uin 120 / 230 Vac) 25 W / 22 W 22 W / 19 W
Operating temperature range –20...+60°C, with derating over 50°C / thermal protection (4)
Input/output isolation 1.5 kVac / 60 s SELV output
Input/PE isolation 1.5 kVac / 60 s
Output/PE isolation 0.5 kVac / 60 s
Safety standards IEC950, EN60950
Electromagnetic compatibility EN55011, EN61000-6-1
MTBF at 25°C and nominal ratings >500'000 h according to SN 29500 / >150'000 h according to MIL Std. HDBK 217F
Overvoltage category / Pollution degree II / 2
Protection degree IP 20 IEC 529 EN60529
Connection type 2.5 mm² removable screw terminal blocks
Housing material aluminium
Approximate weight 500 g
Mounting information vertical on rail, allow 10 mm spacing between adjacent components
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 –

47
Accessory for redundant
power supply connections
• Suitable for connecting non-supplied power supplies
• Compact dimensions 130
• 12, 24 and 48 Vdc selectable operating voltages
• 2 alarm relays
• LED power indicator
43
85

NOTES BLOCK DIAGRAM


The depth measurement includes rail clamp clearance.

VERSIONS Code XCSBD APPLICATIONS


CSBD This module this used for placing two
power supplies without blocking diodes
in parallel; jumpers can be used to
select the desired operating voltage,
GENERAL TECHNICAL DATA and each channel has a relay and
Power supply input voltage 12–24–48 Vdc selectable an LED diode giving you a remote
Power supply nominal current 15 A, max 30 A alarm signal in case a power supply
Nominal load voltage 12–24–48 Vdc selectable switches off.
Maximum load current 15 A
IN/OUT voltage drop 0.7 V at 15 A
Protections —
Alarm signal 2 NA contacts 2A at 230 Vac
Operating temperature range -20...+50°C
Reference Standards IEC 664-1, DIN VDE
Overvoltage category / Pollution degree II / 2
Protection degree IP 00 IEC 529, EN60529
Connection type 2.5 mm² fixed screw terminal blocks
Housing material UL94V-0 plastic
Approximate weight 120 g
Mounting information vertical on rail, side by side
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 PR/DIN/AC, PR/DIN/AS, PR/DIN/AL

Connection Diagram

(A) Power supply


(B) CSBD

48
Accessory for redundant
power supply connections
• Suitable for connecting power supplies without ORing diodes 110
• 12 to 85 V load voltages with currents of up to 50 A
• CPU-controlled electronic redundancy
• Current failure and unbalance alarm
• High efficiency and low consumption
• Compact dimensions 145
40

NOTES BLOCK DIAGRAM


The depth measurement includes rail clamp clearance.
A
IN1
V
OUT
A V
IN2
V

Bar-graph

System
power supply Microprocessor LEDs

OR_OK
Relays
SHARE_OK

VERSIONS Code XCSR50U APPLICATIONS


CSR50U
The CSR50U is an advanced, microprocessor-controlled mod-
ule used for redundant parallel connections of two DC power
supplies in applications needing higher reliability than provided
by common passive ORing modules with diodes to isolate the
GENERAL TECHNICAL DATA outputs of the two power supplies.
Power supply input voltage 12…85 Vdc The CSR50U comes with a current measurement sensor on
Maximum input current 50 A each input to detect the correct supplied by the two power
Power supply input voltage 10.8…85 Vdc supplies and signal an alarm when the current supplied is
Maximum load current 50 A (max. 300 A peak) unbalanced. An imbalance greater than 60% in the supply
IN/OUT voltage drop 0.2 V at 50 A current is a certain indicator that one of the power supplies is
Protections reverse polarity/input surge failing. Detecting this situation and signalling an alarm with an
Status display Green LED indicating input voltage on SPST contact allows preventative maintenance to take place
Red redundancy alarm LED and increases the system's reliability.
Redundant failure contact (24V/1A) In redundant systems where an imbalance in the supply is not
Current share LED bar (unbalance control) controlled, it is not possible to monitor the correct supply of
Current share failure contact (unbalance control) current from the two power sources. This setup permits a situ-
Efficiency >98% (12 V / 50A) ation in which the current is supplied by only one power source,
Dissipated power 10 W which then is forced to work under greater stress. Furthermore,
the power source which supplies less current (or no current)
Operating temperature range -20...+50°C
may not trigger an alarm in certain conditions.
Input/output isolation 0.5 kVac / 60 s
The CSR50U allows two identical power supplies to be con-
Input/PE isolation 0.5 kVac / 60 s
nected for a total current output of 50 A and overall voltage
Output/PE isolation 0.5 kVac / 60 s from 12 to 85 Vdc.
Safety standards EN 60950 Thanks to the ORing and isolation between the two power
Electromagnetic compatibility EN 61000-6-2, EN 61000-6-4 supplies with the microprocessor-controlled MOSFET, the
MTBF at 25°C and nominal ratings >500'000 h according to SN 29500 / >150'000 h according to MIL Std. power dissipated is one tenth of what redundant modules with
HDBK 217F diodes dissipate.
Overvoltage category / Pollution degree II / 2 In addition, CSR50Us can be connected together to obtain
Protection degree IP 20 IEC 529, EN60529 redundancy of more than two systems.
Connection type 16 mm² (IN/OUT) and 1.5 mm² (signal) removable screw terminal blocks The CSR50U provides status displays on:
Housing material aluminium • a fault or power loss in one of the two power supplies
Approximate weight 200 g • unbalanced current supplies greater than 60%
Mounting information vertical on rail, allow 10 mm spacing between adjacent components
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 -

49
MBC2K
DC bus-powered engine braking device

MBC2K is a microprocessor-controlled device designed for braking DC bus-powered engines. It


is activated by the surge generated by the engine when its drive requires braking.
When the MBC2K is connected on the DC bus powering the engine drive (see diagram in fig. 1),
the device activates automatically when the DC bus voltage exceeds the set threshold and
transfers the power generated by the engine to the braking resistor, where it is dissipated.
MBC2k is equipped with protection against short circuit, overload and over temperature in order
to guarantee reliable operation. MBC2K can be connected to any DC bus power supply with a
voltage within 24 and 100 Vdc. The simplified application is illustrated in the block diagram in
Figure 1, the front view of the unit with all controls and functions is shown in Figure 2. CONNECT
up to 4 units in parallel to increase the peak braking power up to 8 KW. MBC2K also has a
7-segment display and an LED for instantly viewing the DC bus voltage (accuracy +/- 1 V) which
helps the user during set-up and in displaying error messages.

MBC2K setup
The MBC2K unit must be set-up prior to operation.
The menu comprises three pages, navigable using the MENU button;
The values shown can be adjusted by pressing the SET/RESET button.
a) brake intervention threshold (VTH)
b) brake intervention threshold hysteresis
c) Master/Slave mode; for selecting single mode (Master mode) or for parallel connection of up
to 4 cards (1 Master+3 Slave).

Active protections
The MBC2K integrates active protections to ensure stable and reliable operation under normal
use conditions. When it detects a fault, MBC2K turns itself off to prevent an uncontrolled flow of
current through the braking resistor.
Fault status is indicated by the alarm LED flashing continuously.
And the integrated alarm relay allows the status of the module to be checked remotely.
To help the user understand which defect has occurred, an error code is shown on the 7-segment Figure 1 application block diagram
display.

Connect up to 4 MBC2K units in parallel DC power


supply DC Motor drive Motor
Up to 4 MBC2K units can be connected in parallel to increase peak braking capacity to 8 KW. 24Vdc-100Vdc
Each unit is capable of braking 2 KW of peak power, for which each unit requires its own braking
resistor. To set up this configuration, MBC2K is equipped with a bus that is used to synchronise
the operation of all connected units (up to 4 max.). The principle of operation is based on one DC IN

MBC2K unit configured as a Master and the other MBC2K units (up to 3) configured as Slaves.
The Master measures the DC bus voltage and decides when to insert the braking resistors into
the circuit, sending a command on the synchronisation bus. When the Slave units connected
MBC2K
to the synchronisation bus receive the command from the Master unit, they insert their braking
resistor into the circuit. When MBC2K is configured in Slave mode, all of its protective circuits R BRAKE

remain operational. I Brake

R Brake
<2kW

1. SET / RESET: Used to reset any errors and to change configurations in set-up mode.
2. MENU: Used to enter set-up mode and to navigate through the menu pages.
3. Synchronisation bus connector: used to connect up to 4 units in parallel.
4. Braking resistor thermostat connector: used to connect a thermostat present on the braking
resistor (Klixson normally closed type is recommended; if not used, short-circuit the 2 terminals).
5. Remote alarm connector: an SPDT contact triggers the fault/malfunction signal.
6. Braking resistor connector: used to connect the external braking resistor.
7. DC bus connector: used to connect MBC2K to the 24 …100Vdc DC bus power supply.
8. Protective earth (PE) connector: used to connect the device to the ground protection.
9. 100s display: used to view numbers >99; e.g. if the indicator is on and the display reads “03”, the
measurement is 103V.
10. Braking indicator: indicates that the unit is braking the engine and supplying current to the braking
R.
11. 7-segment display: when the unit is in operation, this shows the DC bus voltage (accuracy +/-1V);
it is also used to display menu items and error codes.
12. Alarm LED: indicates a fault or error status.

Figure 2 MBC2K - Front view

50
Motor brake controller
• 20 automatically activated threshold levels
• Each module can handle a braking power of 2 kW 115
• Connect up to 4 cards in parallel to run a braking power of 8 kW
• Simple function programming
• Braking resistor temperature control
128 Item available until supplies last
39

NOTES BLOCK DIAGRAM


Block Diagram
The depth measurement includes terminal block and rail clamp
clearance. Alarm Sync T sense R Brake

Synchronization Display and


bus driver and buttons
receiver

DC/DC power
supply Mosfet
Microprocessor
driver and
short circuit
protection
DC IN

VERSIONS Code XMBC2K APPLICATIONS


MBC2K MBC2K is a microprocessor-controlled
device designed for braking DC bus-
powered engines. It is activated by the
surge generated by the engine when its
INPUT TECHNICAL DATA drive requires braking.
DC bus range 24…100 Vdc When the MBC2K is connected on the
Maximum braking current 50 A for 1 s DC bus powering the engine drive (see
Operating voltage when braking 27…106 V, threshold adjustable in 20 steps diagram in fig. 1), the device activates
Threshold hysteresis 3 V or 6 V switchable automatically when the DC bus voltage
User interface 2 setup buttons (SET/RESET and MENU) exceeds the set threshold and transfers
the power generated by the engine to
Two 7-segment displays
the braking resistor, where it is dissi-
1 LED alarm status indicator (general)
pated. MBC2k is equipped with protec-
1 SPDT remote failure contact (general)
tion against short circuit, overload and
Protections Under DC bus voltage (< 22 Vdc) over temperature in order to guarantee
Over DC bus voltage (> 110 Vdc) reliable operation. MBC2K can be con-
Braking resistor overtemperature nected to any DC bus power supply with
(only where a thermostat is connected to the resistor) a voltage within 24 and 100 Vdc. The
Module internal over temperature (temp. > 90°C) simplified application is illustrated in
Braking resistor interrupted or not connected the block diagram in Figure 1, the front
Short-circuit (or braking current > 80A) view of the unit with all controls and
Overload (or braking time > 1 s) functions is shown in Figure 2. Connect
Parallel connection Up to 4 MBC2Ks can be connected in parallel and synchronised through the bus to obtain a total up to 4 units in parallel to increase the
peak braking power of 8 kW (with four 2 kW braking resistors). peak braking power up to 8 KW. MBC2K
GENERAL TECHNICAL DATA also has a 7-segment display and an
Dissipated power 20 W LED for instantly viewing the DC bus
Operating temperature range 0...+70°C voltage (accuracy +/- 1 V) which helps
Input/output isolation — the user during set-up and in displaying
Input/PE isolation 500 Vac / 60s error messages.
Output/PE isolation —
Safety standards IEC950, EN60950 for SELV use up to 60 Vdc; use at higher voltages is not SELV classifiable
Electromagnetic compatibility EN55011 Class B
Overvoltage category / Pollution degree I/2
Protection degree IP 20 IEC 529, EN60529
Connection type 1.5 and 2.5 mm² removable screw terminal blocks
Housing material aluminium
Approximate weight 200 g
Mounting information vertical on rail, allow 10 mm spacing between adjacent components
Approximate weight 120 g
Mounting information vertical on rail, side by side
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 —

51
Adjustable electronic overcurrent
protection from 1...10 A / 24 Vdc
According to the new EN60204-1, it is compulsory to protect wires on SELV-PELV lines from
overcurrent. The standard requires that 24 Vdc overcurrent protections intervene by cutting out the
failure before the control and command 24 Vdc falls below 21.6V, cutting off power to the controls and
preventing the emergency and safety features from activating.
Under EN 60204-1 and EN 61131-1 and -2, overcurrent protection on SELV/PELV lines must be capable
of isolating shorts within 10 ms and hazardous overcurrents within 5 s. The use of power supplies with
a high output overcurrent capacity and fast, accurate protections facilitates fault isolation before the 24
V falls below 21.6 V, leaving the controls without power. Figure 1

Fuses and magneto-thermal switches inserted on 24 Vdc lines have characteristic intervention I/ts
that are not suitable for isolating faults with the required speed and accuracy, while the fuses may be
replaced with different types, affecting the behaviour of the protection and the safety of the system.

The proper coordination of the circuit in which the overcurrent protection is inserted must consider the
total R of the line as: R connections + R wires + R protection + R residual malfunctioning load. The
total R must always allow a safe current to circulate in the circuit once the protection is triggered and
the protection should neither be undersized, to prevent undesirable bursts at peak load, nor oversized,
to prolong its intervention t.

The entire circuit, including power supply, protection, wiring and connections, must be designed such that
all overcurrents can be cut-off within 5 s before the 24 Vdc falls below 21.6 Vdc. This requirement can
be met with Cabur's CSF and CSG series power supplies, designed to provide a high output overcurrent
(nom. I >+50% for > 5s) and CEP System electronic overcurrent protections with an accuracy and speed
far superior to magneto-thermal switches and fuses, whose trigger t is independent of ambient T and
can be reset locally or remotely.

Protection features
MGTs have two different intervention curves: Thermal and magnetic. The magnetic relay only triggers
in the event of a short with different I/t curves; thermal relays all have the same intervention curve
regardless of the MGT curve and in the event of an overload they behave as shown in figure 2: overload
currents of 1.13 x In are cut in >1h, and at overcurrent > 1.45 x In, the trigger occurs in several minutes.
The disconnection of short-circuit currents is activated by the magnetic relay whose trigger t ranges from
0.01 to 0.1 s, and it occurs at very high currents which the power supply used may not be able to deliver:
a C5 MGT used in DC has a safe trigger of > 70 A, a current which only (but not all) power supplies with a
far higher nom. I, e.g. 40 A, are capable of providing, but which is not deliverable by 10 A power supplies.
Using MGT as an overcurrent protection, if the power supply used has an overload I 1.2 times greater
than its nominal I, disconnection will occur after 20…60 minutes, while with a current 2.5 times higher Figure 3
than the nominal I it will trigger after 25 s to 2 min., depending on the Tamb, times which are too long
to guarantee stability at 24V to protect wiring and protection selectivity. In case of malfunction, until the
protection triggers, the power supply remains in overload in excess of x 1.5 x 5 s and the 24 V falls below
21.6 V, leaving normal functions and particularly the safety functions without power.

Protection selectivity
In case of an overload or short, only the malfunctioning circuit is isolated from its protection without
any effects on the power to the other loads. This feature is obtained using power supplies with a high
overcurrent capacity and quick and precise protections.

CEP system – the smart current control system


CEP “recognises” overcurrent at the lowest and most precise threshold and isolates the malfunctioning
circuit in the fastest possible time. For maximum flexibility of use, the CEP system allows you to set 10
trigger currents from 1 A to 10 A in 1 A increments, and has 3 intervention curves: “Rapid – Normal – Figure 4
Delayed” (see fig. 3).
The protection status is indicated by two LEDs and a remote alarm transistor output, while the load can
be activated/deactivated using the button on the front (fig. 5) or controlled remotely by PLC. The ability
to control individual channels separately is useful during installation since various components can be
activated and tested individually, while in large plants, the remote control feature can be used to gradually
activate the various loads, preventing multiple simultaneous overloads at system start-up. An additional
safety feature is manual disconnection, with which even when reactivating the protections remotely the
load will remain inactive, preventing hazardous operating conditions.

Figure 5
52
Adjustable electronic
overcurrent protection
from 1...10 A / 24 Vdc
• Programmable from 1 A to 10 A in 1 A increments 115
• 3 programmable characteristic curves
• Remote or local ON/OFF control
• Green ON/red OFF status LED and remote signalling
• Slide contact for manual disconnection 116
• Sealable front cover for programming protection 8
E258138

NOTES BLOCK DIAGRAM


1) s ealable cover
(2) Remote control is through 24 Vdc pulses. Such pulse 2) p rogramming current
durations should be: = impulse > 1 s / OFF = impulse > 3) identification tag
100 ms and < 800 ms 4)p r o g r a m m i n g
intervention curve
(3) The 3 standard characteristic curves are shown in the 5) r eplacing the fuse
diagrams; the CEP-D3 version also has a software-
programmable curve.

VERSIONS Code XCEPD1 Code XCEPD2 Code XCEPD3


With overload indication CEP-D1

INPUT TECHNICAL DATA


Nominal voltage 24 Vdc (range 18…32 Vdc)
Nominal current 10 A DC max
Max. system current 40 A DC with CEP-RCC distribution bar
CEP-BCR and CEP-BCB
Protection internal electronic reverse polarity
Remote ON/OFF control external 24 Vdc pulse
OUTPUT TECHNICAL DATA
Nominal voltage 24 Vdc (voltage drop <170 mV at Un / In)
Min./max. current 1...10 A DC programmable in 1 A increments
Default trip curves slow, medium and fast
Max. connectable output capacity 10,000 μF
Status indicator Green LED: constant = OK, flashing = Iout at 90% of nominal, red LED: constant = output manually
switched off, flashing slowly = overcurrent, flashing quickly = error
Status display transistor for overload detection
GENERAL TECHNICAL DATA
Operating temperature range –25...+60°C, derating Imax. 8 A over 40°C CEP-MTW
Input/output isolation 3 kVac / 60 s SELV output
Protection degree IP 20 IEC 529, EN60529
Reference Standards EN60950-1, EN61131-1, EN61131-2, EN60898, EN60947-4-1, EN50081
Connection type 0.25...2.5 mm² fixed-clamp spring terminal blocks
Housing material PA 6.6 (UL94V-0, NFF I2, F2)
Approximate weight 120 g
Mounting information vertical or horizontal on rail, side-by-side, use of end brackets advised
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 —
Power supply kit (terminal block + closure) CEP-SS (code XCEPSS)
Distribution bar CEP-RCC (code XCEPRCC) CEP-SS
Isolating distribution bar cover CEP-RCP (code XCEPRCP)
Cross connection bridge red CEP-BCR (code XCEPBCR) (8 poles)
blue CEP-BCB (code XCEPBCB) (8 poles)
Identification tag CEP-MTW (code XCEPMTW) (table with 50 tags) Characteristic curve:
1) fast
2) medium
3) slow

➀ ➁ ➂

53
These tables are used for quickly identifying items and verifying whether all of the product’s technical details satisfy the set requirements.

3-phase filter without neutral 400-480 Vac


Common mode (L / PE) attenuation (dB) Differential mode (L / L) attenuation (dB)
Current 0.15 0.5 1 5 0.15 0.5 1 5 Cat. No. Page
10 MHz 30 MHz 10 MHz 30 MHz
MHz MHz MHz MHz MHz MHz MHz MHz
7A 20 60 60 60 50 35 25 60 65 60 55 40 XF07TDVST2 55
16 A 15 50 55 60 50 35 25 55 60 60 55 40 XF16TDVST2 55
30 A 15 50 55 60 50 35 25 55 60 60 55 40 XF30TDVST2 55
42 A 55 70 70 45 35 20 45 45 45 45 45 30 XF42TDVST2 55
55 A 15 55 55 55 50 35 25 55 60 60 50 40 XF55TDVST2 55
75 A 15 55 55 55 50 30 20 50 50 50 55 40 XF75TDVST2 55
100 A 35 50 45 25 15 7 30 35 35 35 30 7 XF100TDVST2 55
150 A 20 30 40 45 40 30 30 40 40 45 40 25 XF150TDS84C 56
180 A 20 30 40 45 40 30 30 40 40 45 40 25 XF180TDS84C 56
200 A 55 60 55 30 20 – 45 30 25 10 10 5 XF200TDDS84C 57
300 A 30 30 23 10 8 5 35 30 25 14 10 5 XF300TDSS84C 58
400 A 30 30 20 10 5 2 30 30 20 10 8 2 XF400TDSS84C 58

3-phase filter with neutral 400-480 Vac


Common mode (L / PE) attenuation (dB) Differential mode (L / L) attenuation (dB)
Current 0.15 0.5 1 5 0.15 0.5 1 5 Cat. No. Page
10 MHz 30 MHz 10 MHz 30 MHz
MHz MHz MHz MHz MHz MHz MHz MHz
10 A 10 20 20 20 30 25 10 20 25 25 30 30 XF10TYG9 60
16 A 25 50 50 50 45 30 35 55 60 60 40 30 XF16TYT8 59
20 A 10 15 20 35 40 25 10 15 20 20 25 20 XF20TYS9 60
25 A 25 50 50 50 45 30 35 55 60 60 40 30 XF25TYT8 59
36 A 25 50 50 50 40 25 30 50 55 50 40 30 XF36TYT8 59
50 A 25 45 45 40 40 25 30 50 50 40 40 30 XF50TYT8 59
100 A 10 20 25 30 30 20 30 40 40 35 35 25 XF100TYT8 59

Single-cell single-phase filter 120-250 Vac


Common mode (L / PE) attenuation (dB) Differential mode (L / L) attenuation (dB)
Current 0.15 0.5 1 5 0.15 0.5 1 5 Cat. No. Page
10 MHz 30 MHz 10 MHz 30 MHz
MHz MHz MHz MHz MHz MHz MHz MHz
3A 20 30 35 45 50 45 7 35 50 45 45 45 XF03DKBG5B 61
6A 15 20 25 40 45 45 10 20 45 45 50 45 XF06DKBG5B 61
12 A 10 20 22 35 45 40 10 20 40 45 45 45 XF12DKBG5B 61
16 A 10 18 20 35 45 30 10 18 40 40 40 35 XF16DKCG5B 61
20 A 10 18 20 30 35 35 10 12 35 35 40 40 XF20DKCG5B 61
30 A 10 25 30 45 50 35 12 40 50 50 50 45 XF30DKCS5B 61

Double-cell single-phase filter 120-250 Vac


Common mode (L / PE) attenuation (dB) Differential mode (L / L) attenuation (dB)
Current 0.15 0.5 1 5 0.15 0.5 1 5 Cat. No. Page
10 MHz 30 MHz 10 MHz 30 MHz
MHz MHz MHz MHz MHz MHz MHz MHz
3A 45 60 60 55 45 45 12 45 45 45 45 45 XF03DPCG5C 62
6A 30 50 60 55 50 35 8 45 45 45 45 45 XF06DPCG5C 62
12 A 15 25 35 55 55 35 12 40 40 35 35 40 XF12DPCG5C 62
16 A 20 35 45 60 50 35 12 40 40 45 45 50 XF16DPCG5C 62
20 A 15 40 45 50 50 40 12 45 45 45 35 50 XF20DPCG5C 62
30 A 10 30 35 55 45 30 18 45 50 40 40 40 XF30DPGS5C 62

54
3-phase filter without
neutral TDV series
C
• Models from 7 to 130 A
• Elevated attenuation from 150 kHz to 30 MHz
• Elevated attenuation even on long cables
• Minimum surface occupied on the panel B

NOTES BLOCK DIAGRAM


The dimensions and diagrams are purely indicative, for more L1 L1’
detailed information see the product’s technical data. L
(1) The capacitors between phase and neutral, requires that
L2 L2’
the isolation tests are carried out in DC in accordance with
LINE L LOAD
EN60950
(2) Version made to order (not kept in stock); contact our sales L3 L3’
office for availability. Cx1 Cx2 R1

PE Cy R2 PE

VERSIONS Dimensions Weight


Nominal current Type Cat. No. A B C (kg)
7A F 07 TDV ST2 XF07TDVST2 (2) 42 192 72
16 A F 16 TDV ST2 XF16TDVST2 (2) 47 252 72
30 A F 30 TDV ST2 XF30TDVST2 (2) 52 272 87
42 A F 42 TDV ST2 XF42TDVST2 (2) 52 312 87
55 A F 55 TDV ST2 XF55TDVST2 (2) 87 252 92
75 A F 75 TDV ST2 XF75TDVST2 (2) 92 272 137
100 A F 100 TDV ST2 XF100TDVST2 (2) 90 270 150
GENERAL TECHNICAL DATA
Nominal voltage 480 Vac ± 10%
Nominal current See table for versions
Frequency 50…60 Hz
Leakage current at 480 Vac 60 Hz 30 mA
Operating temperature range -25...+85°C
Isolation L/L 1.45 KVdc / 60 s (1)
Isolation L/PE 2.25 KVdc / 60 s (1)
Overvoltage category / Pollution degree —
Protection degree IP 20 IEC 529, EN60529
Connection type fixed screw terminal blocks
Housing material metallic
Approximate weight See table for versions
Mounting information on panels by means of anchorage screws

Common mode (L / PE) attenuation (dB) Differential mode (L / L) attenuation (dB)


Type 0.15 0.5 1 5 0.15 0.5 1 5
10 MHz 30 MHz 10 MHz 30 MHz
MHz MHz MHz MHz MHz MHz MHz MHz
F 07 TDV ST2 20 60 60 60 50 35 25 60 65 60 55 40
F 16 TDV ST2 15 50 55 60 50 35 25 55 60 60 55 40
F 30 TDV ST2 15 50 55 60 50 35 25 55 60 60 55 40
F 42 TDV ST2 55 70 70 45 35 20 45 45 45 45 45 30
F 55 TDV ST2 15 55 55 55 50 35 25 55 60 60 50 40
F 75 TDV ST2 15 55 55 55 50 30 20 50 50 50 55 40
F 100 TDV ST2 35 50 45 25 15 7 30 35 35 35 30 7

55
3-phase filter without
neutral TDS series
• Models from 150 to 180 A C
• Elevated attenuation from 150 kHz to 30 MHz PRELIMINARY
• Elevated attenuation even on long cables

NOTES BLOCK DIAGRAM


The dimensions and diagrams are purely indicative, for more
detailed information see the product’s technical data. L1 L1’
(1) Version made to order (not kept in stock); contact our sales
office for availability. L2 L2’
(2) The capacitors between phase and neutral, requires that LINE LOAD
the isolation tests are carried out in DC in accordance with
L3 L3’
EN60950.

PE PE

VERSIONS Dimensions Weight


Nominal current Type Cat. No. A B C (kg)
150 A F 150 TDS 84C XF150TDS84C (1) 202 390 122
180 A F 180 TDS 84C XF180TDS84C (1) 202 390 122
GENERAL TECHNICAL DATA
Nominal voltage 480 Vac ± 10%
Nominal current See table for versions
Frequency 50…60 Hz
Leakage current at 480 Vac 60 Hz 500 mA
Operating temperature range -25...+85°C
Line/line isolation 1 KVdc / 60 s (2)
Line/PE isolation 1 KVdc / 60 s (150A) – 2.25 KVdc / 60 s (180A) (2)
Overvoltage category / Pollution degree —
Protection degree IP 20 IEC 529, EN60529
Connection type self-blocking nut
Housing material metallic
Approximate weight See table for versions
Mounting information on panels by means of anchorage screws

56
3-phase filter without
neutral TDDS series
• Elevated attenuation from 150 kHz to 30 MHz C
• Elevated attenuation even on long cables

A
Item available until supplies last

NOTES BLOCK DIAGRAM


The dimensions and diagrams are purely indicative, for more
detailed information see the product’s technical data. L1 L1’
(1) Item available until supplies last.
(2) The capacitors between phase and neutral, requires that L2 L2’
the isolation tests are carried out in DC in accordance with
LINE LOAD
EN60950.
L3 L3’

PE PE

VERSIONS Dimensions Weight


Nominal current Type Cat. No. A B C (kg)
200 A F 200 TDDS XF200TDDS84C (1) 240 477 140
84C
GENERAL TECHNICAL DATA
Nominal voltage 480 Vac ± 10%
Nominal current 200 A
Frequency 50…60 Hz
Leakage current at 480 Vac 60 Hz 500 mA
Operating temperature range -25...+85°C
Line/line isolation 1 KVdc / 60 s (2)
Line/PE isolation 1.8 KVdc / 60 s (2)
Overvoltage category / Pollution degree —
Protection degree IP 20 IEC 529, EN60529
Connection type self-blocking nut
Housing material metallic
Approximate weight See table for versions
Mounting information on panels by means of anchorage screws

Common mode (L / PE) attenuation (dB) Differential mode (L / L) attenuation (dB)


Type 0.15 0.5 1 5 0.15 0.5 1 5
10 MHz 30 MHz 10 MHz 30 MHz
MHz MHz MHz MHz MHz MHz MHz MHz
F 200 TDDS 84C 55 60 55 30 20 / 45 30 25 10 10 5

57
3-phase filter without
neutral TDSS series
• Models from 300 to 600 A C
• Elevated attenuation from 150 kHz to 30 MHz
• Elevated attenuation even on long cables

A
Item available until supplies last

NOTES BLOCK DIAGRAM


The dimensions and diagrams are purely indicative, for more
detailed information see the product’s technical data. L1 L1’
(1) Item available until supplies last.
(2) The capacitors between phase and neutral, requires that L2 L2’
the isolation tests are carried out in DC in accordance with LINE LOAD
EN60950.
L3 L3’

VERSIONS Dimensions Weight


Nominal current Type Cat. No. A B C (kg)
300 A F 300 TDSS XF300TDSS84C (1) 242 525 142
84C
400 A F 400 TDSS XF400TDSS84C (1) 242 525 142
84C
GENERAL TECHNICAL DATA
Nominal voltage 480 Vac ± 10%
Nominal current See table for versions
Frequency 50…60 Hz
Leakage current at 480 Vac 60 Hz 1000 mA
Operating temperature range -25...+85°C
Line/line isolation 0.6 KVdc / 60 s (2)
Line/PE isolation 1 KVdc / 60 s (2)
Overvoltage category / Pollution degree —
Protection degree IP 20 IEC 529, EN60529
Connection type flat plug
Housing material metallic
Approximate weight See table for versions
Mounting information on panels by means of anchorage screws

58
3-phase filter with neutral
TYT series
• Models from 16 to 100 A
• Elevated attenuation from 150 kHz to 30 MHz C
• Elevated attenuation even on long cables

NOTES BLOCK DIAGRAM


The dimensions and diagrams are purely indicative, for more
L1 L1'
detailed information see the product’s technical data.
L
(1) The capacitors between phase and neutral, requires that
L2 L2'
the isolation tests are carried out in DC in accordance with
LINE L LOAD
EN60950.
(2) Version made to order (not kept in stock); contact our sales L3 L3'
Cx C x1
office for availability. R L

N L4'
Cy Cy

PE PE

VERSIONS Dimensions Weight


Nominal current Type Cat. No. A B C (kg)
36 A F 36 TYT8 XF36TYT8 (2) 107 191.5 82
50 A F 50 TYT8 XF50TYT8 (2) 124 194 104
100 A F 100 TYT8 XF100TYT8 (2) 162 252 132
GENERAL TECHNICAL DATA
Nominal voltage 440 Vac ± 10%
Nominal current See table for versions
Frequency 50...60Hz
Leakage current at 480 Vac 60 Hz 3 mA
Operating temperature range -25...+85°C
Line/line isolation 1.45 KVdc / 60 s (1)
Line/PE isolation 2.25 KVdc / 60 s (1)
Overvoltage category / Pollution degree —
Protection degree IP 20 IEC 529, EN60529
Connection type fixed screw terminal blocks
Housing material metallic
Approximate weight See table for versions
Mounting information on panels by means of anchorage screws

Common mode (L / PE) attenuation (dB) Differential mode (L / L) attenuation (dB)


Type 0.15 0.5 1 5 0.15 0.5 1 5
10 MHz 30 MHz 10 MHz 30 MHz
MHz MHz MHz MHz MHz MHz MHz MHz
F 36 TYT8 25 50 50 50 40 25 30 50 55 50 40 30
F 50 TYT8 25 45 45 40 40 25 30 50 50 40 40 30
F 100 TYT8 10 20 25 30 30 20 30 40 40 35 35 25

59
Compact 3-phase filter
with neutral TY series
• Models from 10 to 20 A
• Elevated attenuation from 150 kHz to 30 MHz C
• Elevated attenuation even on long cables
• Excellent quality/price/performance ratio

NOTES BLOCK DIAGRAM


The dimensions and diagrams are purely indicative, for more L1 L1’

detailed information see the product’s technical data. L

(1) The capacitors between phase and neutral, requires that


L2 L2’
the isolation tests are carried out in DC in accordance with
LINE LOAD
EN60950. L

(2) Version made to order (not kept in stock); contact our sales L3 L3’
Cx Cx Cx
office for availability. L

N N

Cy

PE

VERSIONS Dimensions Weight


Nominal current Type Cat. No. A B C (kg)
10 A F 10 TYG9 XF10TYG9 (2) 50 85 44
20 A F 20 TYS9 XF20TYS9 (2) 50 97 44
GENERAL TECHNICAL DATA
Nominal voltage 440 Vac ± 10%
Nominal current See table for versions
Frequency 50...60Hz
Leakage current at 480 Vac 60 Hz 0.5 mA
Operating temperature range -25...+85°C
Line/line isolation 1.45 KVdc / 60 s (1)
Line/PE isolation 2.25 KVdc / 60 s (1)
Overvoltage category / Pollution degree —
Protection degree IP 20 IEC 529, EN60529
Connection type flat plug (10 A) and screw (20 A)
Housing material metallic
Approximate weight See table for versions
Mounting information on panels by means of anchorage screws

Common mode (L / PE) attenuation (dB) Differential mode (L / L) attenuation (dB)


Type 0.15 0.5 1 5 0.15 0.5 1 5
10 MHz 30 MHz 10 MHz 30 MHz
MHz MHz MHz MHz MHz MHz MHz MHz
F 10T YG9 10 20 20 20 30 25 10 20 25 25 30 30
F 20 TYS9 10 15 20 20 25 20 10 15 20 20 25 20

60
Single-cell single-phase
filter DK series
• Models from 3 to 30 A
• Elevated attenuation from 150 kHz to 30 MHz
C
• Elevated attenuation even on long cables
• Minimum surface occupied on the panel

B
A

NOTES BLOCK DIAGRAM


The dimensions and diagrams are purely indicative, for more
detailed information see the product’s technical data.
(1) 0.25 mA at 115 Vac and 0.45 mA at 250 Vac for 3…20 A - 1
L L'
mA at 115 Vac models and 2 mA at 250 Vac for 30 A models. R
Cy
(2) Version made to order (not kept in stock); contact our sales LINE
Cx
L
Cx
LOAD
office for availability. Cy
(3) Flat plug for 3…20 A models; self-blocking nut for 30 A N N'

model. PE

(4) The capacitors between phase and neutral, requires that


the isolation tests are carried out in DC in accordance with
EN60950.

VERSIONS Dimensions Weight


Nominal current Type Cat. No. A B C (kg)
3A F 03 DK BG5B XF03DKBG5B (2) 64.5 34 30
6A F 06 DK BG5B XF06DKBG5B (2) 64.5 34 30
12 A F 12 DK BG5B XF12DKBG5B (2) 64.5 34 30
16 A F 16 DK CG5B XF16DKCG5B (2) 45.5 71.5 30
20 A F 20 DK CG5B XF20DKCG5B (2) 51.8 84.8 30
30 A F 30 DK CS5B XF30DKCS5B (2) 56.5 114 46.4
GENERAL TECHNICAL DATA
Nominal voltage 115–250 Vac ± 10%
Nominal current See table for versions
Frequency 50…60 Hz
Leakage current at 480 Vac 60 Hz 0.25…1 mA / 0.45…2 mA (1)
Operating temperature range -25...+85°C
Line/line isolation 1.45 KVdc / 60 s (4)
Line/PE isolation 2.25 KVdc / 60 s (4)
Overvoltage category / Pollution degree —
Protection degree IP 20 IEC 529, EN60529
Connection type flat plug (from 3 to 20 A ) / self-blocking nut (30 A) (3)
Housing material metallic
Approximate weight See table for versions
Mounting information on panels by means of anchorage screws

Common mode (L / PE) attenuation (dB) Differential mode (L / L) attenuation (dB)


Type 0.15 0.5 1 5 0.15 0.5 1 5
10 MHz 30 MHz 10 MHz 30 MHz
MHz MHz MHz MHz MHz MHz MHz MHz
F 03 DK BG5B 20 30 35 45 50 45 7 35 50 45 45 45
F 06 DK BG5B 15 20 25 40 45 45 10 20 45 45 50 45
F 12 DK BG5B 10 20 22 35 45 40 10 20 40 45 45 45
F 16 DK CG5B 10 18 20 35 45 30 10 18 40 40 40 35
F 20 DK CG5B 10 18 20 30 35 35 10 12 35 35 40 40
F 30 DK CS5B 10 25 30 45 50 35 12 40 50 50 50 45

61
Double-cell single-phase
filter DP series
• Models from 3 to 30 A
• Elevated attenuation from 150 kHz to 30 MHz C
• Elevated attenuation even on long cables
• Minimum surface occupied on the panel

NOTES BLOCK DIAGRAM


The dimensions and diagrams are purely indicative, for more
detailed information see the product’s technical data.
(1) 0.25 mA at 115 Vac and 0.45 mA at 250 Vac for 3…20 A - 1
L L'
mA at 115 Vac models and 2 mA at 250 Vac for 30 A models. R C3
C1 C2
(2) Version made to order (not kept in stock); contact our sales LINE L1 L2 LOAD
office for availability. C3
N N'
(3) Flat plug for 3…20 A models; self-blocking nut for 30 A
PE PE
model.
(4) The capacitors between phase and neutral, requires that
the isolation tests are carried out in DC in accordance with
EN60950.

VERSIONS Dimensions Weight


Nominal current Type Cat. No. A B C (kg)
3A F 03 DP CG5C XF03DPCG5C (2) 84.8 75 52
6A F 06 DP CG5C XF06DPCG5C (2) 152.9 143 51.3
12 A F 12 DP CG5C XF12DPCG5C (2) 84.8 75 52
16 A F 16 DP CG5C XF16DPCG5C (2)
20 A F 20 DP CG5C XF20DPCG5C (2) 56.5 46.4
30 A F 30 DP GS5C XF30DPGS5C (2)
GENERAL TECHNICAL DATA
Nominal voltage 115–250 Vac ± 10%
Nominal current See table for versions
Frequency 50…60 Hz
Leakage current at 480 Vac 60 Hz 0.25…1 mA / 0.45…2 mA (1)
Operating temperature range -25...+85°C
Line/line isolation 1.45 KVdc / 60 s (4)
Line/PE isolation 2.25 KVdc / 60 s (4)
Overvoltage category / Pollution degree —
Protection degree IP 20 IEC 529, EN60529
Connection type flat plug (from 3 to 20 A ) / self-blocking nut (30 A) (3)
Housing material metallic
Approximate weight See table for versions
Mounting information on panels by means of anchorage screws

Common mode (L / PE) attenuation (dB) Differential mode (L / L) attenuation (dB)


Type 0.15 0.5 1 5 0.15 0.5 1 5
10 MHz 30 MHz 10 MHz 30 MHz
MHz MHz MHz MHz MHz MHz MHz MHz
F 03 DP CG5C 45 60 60 55 45 45 12 45 45 45 45 45
F 06 DP CG5C 30 50 60 55 50 35 8 45 45 45 45 45
F 12 DP CG5C 15 25 35 55 55 35 12 40 40 35 35 40
F 16 DP CG5C 20 35 45 60 50 35 12 40 40 45 45 50
F 20 DP CG5C 15 40 45 50 50 40 12 45 45 40 35 50
F 30 DP GS5C 10 30 35 55 45 30 18 45 50 40 40 40

62
Applications of analogue converters
and galvanic separation

T hey convert electrical signals generated by sensors which take physical measurements
such as temperature (thermocouples and PT100 resistance thermometers), frequency
(proximity, contacts, photocells), current (TA, Hall sensors), resistance (potentiometers), voltage,
pressure, level, etc. into standardised electrical signals, adapting them to PLC, DCS and indus-
trial PC (control) outputs, or they convert a given analogue signal into a different one, adapting
it to control inputs/outputs or allowing for long-distance signal transmission without interfer-
ence by means of galvanic separation (fig. 1).

SIGNAL ADAPTATION

fig. 1

Adaptation between sensor output signal and control input signal

physical measurement taken sensor output converter input converter output


Temperature 0 – 60 mV ±60 mV 0–5V ±5 V
Frequency 0 – 100 mV ±100 mV 0 – 10 V ±10 V
Current 0 – 500 mV ±500 mV 0 – 20 mA ±20 mA
Resistance 0 – 1 V ±1 V 4 – 20 mA
Voltage Normally one of the 0 – 5 V ±5 V
Pressure following signals indicated 0 – 10 V ±10 V
in the next column
Level measurement 0 – 5 mA ±5 mA
0 – 10 mA ±10 mA
0 – 20 mA ±20 mA
0 – 20 mA

Long-distance signal transmission

Voltage signals can reach a max. distance of 10-20 m, beyond which they lose reliability and
become highly sensitive to induced and ground-derived interference, therefore in order to
transmit to distances beyond 20 m a voltage signal must be converted into a current signal
and galvanically separated (fig. 2).
Current signals can surpass a transmission distance of 300 m and are less sensitive to
induced interference. The long-distance transmission of a current signal requires galvanic
separation.

sensor control ➀ Input amplifier


➁ Opto-isolator
➂ Signal adapter
➃ Output amplifier
main ➄ DC/DC Converter

BLOCK DIAGRAM OF AN AMPLIFIER WITH GALVANIC SEPARATION

fig. 2

63
Galvanic signal separation
(signal isolation):
• isolates and electrically separates the sensor circuit from the control
circuit and from the power supply circuit; each circuit therefore operates
in relation to its own zero potential which, being isolated from other Measurement error
circuits, cannot be altered by ever-present potential differences between
different ground references (fig.3)

NON-ISOLATED THERMOCOUPLE AND DIFFERENT GROUND POTENTIALS


fig. 3

• isolates and separates different ground potentials between power supply,


control and sensors/actuators
• allows for signal transmission without errors or interference and with
greater reliability
• the higher the isolation (in kV), the greater the security of the transmis-
sion in the presence of ground potentials, electromagnetic or temporary EARTH
interference (lightning, discharge, etc.). (fig 4)

GROUND CIRCUITS AND POTENTIAL DIFFERENCE

fig. 4

Galvanic separation is necessary when:


• the distance between control and sensor/actuator is greater than 20 m
• ground or mass references are different
• ground potentials are high, or may become high in case of discharges or
currents leaked to ground
• electromagnetic interference is present
• signal cables are wired in ducts with power cables (fig. 5)

INTERFERENCE
fig. 5

Connection of analogue converters in series and in parallel


• To obtain signal redundancy or to simply duplicate it, multiple converter  

 
 
inputs can be connected to a single sensor. 
I

 
• In case of current signals, the converter input will be connected in series    
(fig. 6)
 


I


 
  
CONVERTERS IN SERIES
fig. 6

• In case of voltage signals, the converter input will be connected in


parallel (fig. 7)  

 
U
 


 
   

 


U


 
  

CONVERTERS IN PARALLEL
fig. 7

64
These tables are used for quickly identifying items and verifying whether all of the product’s technical details satisfy the set requirements.

Analogue signal converter and separators


Input Output Isolation Power supply Notes Type Cat. No. Page
0...60 / 0...100 / 0...500 mV 0...5 / 0...10 / ±5 / ±10 V 3-way 24 Vdc (1) (4) CAPIPO3 XCAPIPO3 67
±60 / ±100 / ±500 mV 0...20 / 4...20 / ±20 mA
0...1 / 0...2 / 0...5 / 0...10 V
±1 / ±2 / ±5 / ±10 V
0...5 / 0...10 / 0...20 / 4...20 mA
±5 / ±10 / ±20 mA
0...60 / 0...100 / 0...300 / 0...500 mV 0...10 V 3-way 24 Vac/dc (1) (4) CWUAA 6-0516 X756516 68
0...1 / 0...10 / 0...20 / 2...20 V 0...20 / 4...20 mA
0...5 / 0...10 / 0...20 / 4...20 / ±5 / ±20 mA
0...10 V 0...10 V 3-way 24 Vac/dc (1) (4) CWNAA 7-0539 X756539 69
0...20 / 4...20 mA 0...20 / 4...20 mA
0...10 V 0...10 V 3-way 24 Vac/dc (2) (4) CWAA 6-0530 X756530 70
0...10 V 0...20 mA 3-way 24 Vac/dc (2) (4) CWAA 6-0531 X756531 70
0...10 V 4...20 mA 3-way 24 Vac/dc (2) (4) CWAA 6-0532 X756532 70
0...20 mA 0...10 V 3-way 24 Vac/dc (2) (4) CWAA 6-0533 X756533 71
0...20 mA 0...20 mA 3-way 24 Vac/dc (2) (4) CWAA 6-0534 X756534 71
0...20 mA 4...20 mA 3-way 24 Vac/dc (2) (4) CWAA 6-0535 X756535 71
4...20 mA 0...10 V 3-way 24 Vac/dc (2) (4) CWAA 6-0536 X756536 72
4...20 mA 0...20 mA 3-way 24 Vac/dc (2) (4) CWAA 6-0537 X756537 72
4...20 mA 4...20 mA 3-way 24 Vac/dc (2) (4) CWAA 6-0538 X756538 72
0...20 / 4...20 mA 0...20 / 4...20 mA 2-way — (4) CWPAA 7-0526 X756526 73
0...20 / 4...20 mA 0...20 / 4...20 mA 2-way — (3) (4) CWPAA 7-0527 X756527 73
-30...+30 V / -50...+50 mA / -5...+5 A 2 thresholds (NA contacts) 3-way 24 Vdc (6) (7) LCONALSFDT X756360 74

Notes (4) two-way 1.5 k Vac/60 s (input/output) or three-way 1.5 kVac / 60 s


(1) DIP-switch programmable input and output signals (input/output/power supply) isolation
(2) fixed (non-calibratable) input and output signals, version made to order (not kept in stock), (5) three-way 4 kVac/60 s (input/output/power supply) isolation
for information contact our sales office (6) D IP-switch and software programmable input and output signals
(3) two-channel version (7) three-way 2.5 kVac/60 s (input/output/power supply) isolation

Current converters
Input Output Isolation Power supply Notes Type Cat. No. Page
0…50 A ac adjustable threshold 1…30 2-way 24 Vdc (3) (4) CCIS-2 XCCIS2 79
A
0…1 A ac/dc 0...10 V 3-way 24 Vdc (2) WAA 7-0540 X756540 80
0...20 / 4...20 mA
0…5 A ac/dc 0...10 V 3-way 24 Vdc (2) WAA 7-0541 X756541 80
0...20 / 4...20 mA
0…10 A ac/dc 0...10 V 3-way 24 Vdc (2) WAA 7-0542 X756542 80
0...20 / 4...20 mA

Notes
(1) version with single input and output signals (3) version with open collector threshold output
(2) version with three selectable output signals (4) version with threshold output with 1 exchange relay

Frequency/analogue programmable converters


Input Output Isolation Power supply Notes Type Cat. No. Page
0…28.8 kHz (21 steps) 0...10 V 2-way 24 Vac/dc (1) CWNFA 6-0524 X756524 82
0...20 / 4...20 mA

65
These tables are used for quickly identifying items and verifying whether all of the product’s technical details satisfy the set requirements.

Auxiliary power supply for sensors and potentiometers


Input Output Isolation Power supply Notes Type Cat. No. Page
24 Vdc 10 Vdc 2-way CWCV 7-6184 X766184 83

NPN and PNP signal inverter


Input Output Isolation Power supply Notes Type Cat. No. Page
NPN (17…30 Vdc) PNP CI-NPN/PNP XNPNPNP 84
PNP (17…30 Vdc) NPN CI-NPN/PNP XNPNPNP 84

Temperature sensor converters


Sensor type Input Output Isolation Power supply Notes Type Cat. No. Page
PT100 and PT1000 Programmable 0...10 V / -10...+10 V 3-way 24 Vdc (1) (2) LCONTADFDT X756340 75
(2, 3, 4 wires) Thermocou- -200...+2400°C (-328...+4352°F) 0...20 mA / 4...+20 mA
ples B, C, E, J, K, N, R, S, T based on sensor type
0-600 kOhm potentiometers
PT100 and PT1000 Programmable 2 thresholds 3-way 24 Vdc (2) LCONTLSFDT X756370 76
(2, 3, 4 wires) Thermocou- -200...+2400°C (-328...+4352°F) (NA contacts)
ples B, C, E, J, K, N, R, S, T based on sensor type
0-600 kOhm potentiometers
PT100 3 wires -50…+50°C (-58…+122°F) 0...10 V 3-way 24 Vac/dc (2) CWPT 6-0816 X756816 77
(RTD) -50…+100°C (-58…+212°F) 0...20 / 4...20 mA
-50…+150°C (-58…+302°F)
0…+100°C (+32…+212°F)
0…+150°C (+32…+302°F)
0…+200°C (+32…+392°F)
0…+300°C (+32…+572°F)
0…+400°C (+32…+752°F)
Thermocouples -50…+200°C (-58…+392°F) 0...10 V 3-way 24 Vac/dc (2) CWTH 6-0844 X756844 78
J (FeCuNi) and -50…+350°C (-58 …+662°F) 0...20 / 4...20 mA
K (NiCrNi) 0…+200°C (+32…+392°F)
0…+400°C (+32…+752°F)
0…+600°C (+32…+1112°F)
0…+800°C (+32…+1472°F)
0…+1000°C (+32…+1832°F)
0…+1200°C (+32…+2192°F)

Notes
(1) software programmable input and output signals
(2) DIP-switch programmable input and output signals

66
Analogue programmable
signal converters
• 19 input steps 108
• 7 output steps
• 1 failure contact
• Input/Output isolation > 3 kVac
• Auxiliary power supply for loop powered sensors
119
• Potentiometer input 22.5

NOTES BLOCK DIAGRAM


Depth measurements include terminal block and
rail clamp clearance.
(1) Stock cards are programmed and calibrated
with input 0…10 V and output 0…10 V. cards
programmed and calibrated for all other possible
configurations are available upon request.

VERSIONS Cat. No. XCAPIPO3


Standard CAPIPO3

INPUT TECHNICAL DATA


Input signal (1) 19 programmable steps (see tab. 1)
Voltage/current impedance 1 MΩ / 50 Ω
Max. input voltage 15 V
Max. input current 30 mA
INPUT STAGE
The module can manage single-pole and two-pole inputs
OUTPUT TECHNICAL DATA selecting between steps (see TAB. 1):
Output signal (1) 7 programmable steps (see tab. 2)
Voltage/current output load ≥ 10 kΩ / ≤ 500 Ω
• 0…60 mV ± 60 mV
Max. output voltage 12 V • 0…100 mV ± 100 mV
Max. outrush current 25 mA • 0…500 mV ± 500 mV
• 0…1 V ±1V
GENERAL TECHNICAL DATA • 0…5 V ±5V
Power supply voltage 15...36 Vdc
• 0…10 V ± 10 V
Power consumption 100 mA max. at 24 Vdc • 0…5 mA ± 5 mA
Max. auxiliary voltage I 10 Vdc 5 mA / 24 Vdc 30 mA • 0…10 mA ± 10 mA
Gain error < 0.1% FS • 0…20 mA ± 20 mA
Offset error < 0.05 % FS • 4…20 mA
Linearity error < 0.1% FS The input stage provides two power supplies (10 V and
Zero adjustment/span adj. ± 10% FS / ± 10% FS 24 V) for remote sensors. It is possible to run potentiome-
Conversion frequency 400Hz...1kHz depending on full scale ters and directly power 4…20 mA two-wire loop sensors.
Rise time 150 mV / µs
Bandwidth 1 kHz at -6 dB Connection examples:
Phase delay < 10 µs
Input/Output/Power supply isolation > 3 kVac / 60 s
Permanent voltage isolation 800 Vac max. sensor sensor
Reference Standards IEC 664-1, DIN VDE0110.1 2-wire 3-wire
Overvoltage category / Pollution degree III / 2
Operating temperature range -10... +65°C
∆T 5°C potentiometer
Protection degree IP 20 IEC 529, EN60529 ≥ 1 kΩ
EMC standards EN 50081-2, EN 50082-2
Connection type 2.5 mm² removable screw terminal blocks
Housing material UL94V-0 polyamide
Approximate weight 150 g
Mounting information vertical on rails, space 5 mm from adjacent components OUTPUT STAGE
The module provides single-pole and two-pole output
MOUNTING ACCESSORIES signals with the following steps (see Tab. 2):
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB • 0…5 V ±5V
Mounting rail type according to IEC60715/G32 — • 0…10 V ± 10 V
Jumperred — • 0…20 mA ± 20 mA
white — • 4…20 mA
blue —

67
Programmable analogue
signal converter
• 3-way galvanic separation 79
• 14 programmable input ranges
• 3 programmable output ranges
• Simplified programming
• Version available with 24-240 Vac/dc power supply 84
17.5

NOTES BLOCK DIAGRAM


Depth measurements include terminal block and rail clamp
clearance.
(1) settable using a rotary switch
(2) settable using a DIP-switch
(3) range 16.8…30 Vdc / 19.2…28.8 Vac
(4) range 16.8…264 Vdc / 19.2…264 Vac
(5) 3-way, IN/OUT/power supply Power supply
(6) Version made to order (not kept in stock); contact our sales 24 Vac/dc
office for availability.

VERSIONS Cat. No. X756516 APPLICATIONS


CWUAA 6-0516 Converts and galvanically isolates
the main standardised analogue
signals; input programmable with
INPUT TECHNICAL DATA 14 signal ranges and output with
Input signal (1) 0...60 / 0...100 / 0...300 / 0…500 mV the three most used standardised
0…1 / 0…10 / 0…20 / 2…20 V signals. Configuration is obtained
0…5 / 0…10 / 0…20 / 4…20 / ±5 / ±20 mA by setting the DIP-switches on the
Input resistance 330 kΩ with voltage input side.
100 kΩ with current input This module offers multiple in/out
signal combinations, allowing for
significant savings in terms of costs,
OUTPUT TECHNICAL DATA time and storage space and in the
Output signal (2) 0…10 V
management of spare parts.
0…20 / 4…20 mA
3-way galvanic separation ensures
Applicable load >1 kΩ with voltage output
total isolation between input, output
<400 Ω with current output
and power supply which, together
with automatic signal calibration,
GENERAL TECHNICAL DATA ensures excellent precision without
Power supply voltage 24 Vac/dc (3) the need for calibration.
Power consumption ≤ 35 mA ± 10% at 24 Vdc Where multiple output channels are
Accuracy 0.1% at 23°C FS needed for a single signal source,
Conversion frequency < 30 Hz multiple converters may be used
Temperature coefficient 0.02% / K FS connecting the signal inputs in par-
Isolation 1.5 kVac / 60 s (5) allel, in the case of voltage signals,
EMC standards EN 50081-2, EN 50082-2 or in series, in the case of current
Reference Standards IEC 664-1, DIN VDE signals.
Overvoltage category / Pollution degree III / 2
Protection degree IP 20 IEC 529, EN60529
Operating temperature range -25…+60°C
Connection type 2.5 mm² fixed screw terminal blocks
Housing material UL94V-0 Noryl
Approximate weight 65 g
Mounting information vertical on rails, side by side

MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 —
Jumperred —
(16 poles, 16 A) white —
blue —

68
Programmable analogue
signal converters
• 1.5 kV 3-way input/output/power supply isolation 90
• 3 programmable input ranges
• 3 programmable output ranges
• Simplified, self-adjusting programming
• Version available with 24-240 Vac/dc power supply 92.5
6.2

NOTES BLOCK DIAGRAM


Depth measurements include terminal block and rail clamp
clearance.
(1) range 16.8…30 Vdc / 19.2…28.8 Vac
(2) range 16.8…264 Vdc / 19.2…264 Vac
(3) 3-way, IN/OUT/power supply

Power supply
24 Vac/dc

VERSIONS Cat. No. X756539 APPLICATIONS


CWNAA-7-0539 Convert and galvanically isolate
the main standardised analogue
signals; input programmable with
INPUT TECHNICAL DATA 3 signal ranges and output with
Input signal 0…10 V the 3 most used standard signals.
0…20 / 4…20 mA Configuration is obtained by set-
Input resistance 330 kΩ with voltage input ting the DIP-switches on the side.
100 Ω with current input Programmable in the most used
signal combinations, these cards
allow for a significant cost saving
OUTPUT TECHNICAL DATA over the more complex 14 range
Output signal 0…10 V
version. Where multiple output
0…20 / 4…20 mA
channels are needed for a single
Applicable load >1 kΩ with voltage output
signal source, multiple converters
<400 Ω with current output
may be used connecting the sig-
nal inputs in parallel (with voltage
GENERAL TECHNICAL DATA signals) or in series (with current
Power supply voltage 24 Vac/dc (1) signals).
Power consumption ≤ 35 mA ± 10% at 24 Vdc
Accuracy 0.1% at 23°C FS
Conversion frequency < 30 Hz
Temperature coefficient 0.02% / K FS
Isolation 1.5 kVac / 60 s (3)
EMC standards EN 61000-6-2, EN 61000-6-4
Reference Standards IEC 664-1, DIN VDE
Overvoltage category / Pollution degree III / 2
Protection degree IP 20 IEC 529, EN60529
Operating temperature range -25…+60°C
Connection type 2.5 mm² fixed screw terminal blocks
Housing material UL94V-0 Noryl
Approximate weight 40 g
Mounting information vertical on rails, side by side

MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 —
Jumperred CWBK 7-0802 Cat. No. X766802 —
(16 poles, 16 A) white CWBK 7-0803 Cat. No. X766803 —
blue CWBK 7-0804 Cat. No. X766804 —

69
Analogue
signal converters
• 1.5 kV 3-way input/output/power supply isolation 90
• Fixed value
• Compact size, 6.2 mm thick

92.5
6.2

NOTES BLOCK DIAGRAM


Depth measurements include terminal block and rail clamp
clearance.
(1) range 16.8…30 Vdc / 19.2…28.8 Vac
(2) 3-way, IN/OUT/power supply

Power supply
24 Vac/dc

VERSIONS Cat. No. X756530 Cat. No. X756531 Cat. No. X756532 APPLICATIONS
IN: 0...10 V / OUT: 0...10 V CWAA 7-0530 Convert and galvanically isolate
IN: 0...10 V / OUT: 0...20 mA CWAA 7-0531 the main analogue signals into a
IN: 0...10 V / OUT: 4...20 mA CWAA 7-0532 proportional signal; each model is
INPUT TECHNICAL DATA designed to convert a single ana-
Input signal 0…10 V 0…10 V 0…10 V logue signal providing a substantial
Input resistance 330 kΩ 330 kΩ 330 kΩ reduction in components and costs,
making it the perfect solution for
large plants and applications which
OUTPUT TECHNICAL DATA use multiple signals of the same
Output signal 0...10 V 0...20 mA 4...20 mA type, where programmable cards
Applicable load >1 kΩ <400 Ω <400 Ω would drive up costs. Equipped with
3-way galvanic separation between
GENERAL TECHNICAL DATA input, output and power supply.
Power supply voltage 24 Vac/dc (1) 24 Vac/dc (1) 24 Vac/dc (1) Where multiple output channels are
Power consumption ≤ 13 mA ± 10% ≤ 13 mA ± 10% ≤ 13 mA ± 10% needed for a single signal source,
Accuracy 0.1% at 23°C FS 0.1% at 23°C FS 0.1% at 23°C FS multiple converters may be used
Conversion frequency < 30 Hz < 30 Hz < 30 Hz connecting the signal inputs in par-
Temperature coefficient 0.02% / K FS 0.02% / K FS 0.02% / K FS allel (with voltage signals) or in
Isolation 1.5 kVac / 60 s (2) 1.5 kVac / 60 s (2) 1.5 kVac / 60 s (2) series (with current signals).
EMC standards EN 61000-6-2, EN 61000-6-4 EN 61000-6-2, EN 61000-6-4 EN 61000-6-2, EN 61000-6-4
Reference Standards IEC 664-1, DIN VDE IEC 664-1, DIN VDE IEC 664-1, DIN VDE
Overvoltage category / Pollution degree III / 2 III / 2 III / 2
Protection degree IP 20 IEC 529, EN60529 IP 20 IEC 529, EN60529 IP 20 IEC 529, EN60529
Operating temperature range -25…+60°C -25…+60°C -25…+60°C
Connection type 2.5 mm² fixed screw terminal 2.5 mm² fixed screw terminal 2.5 mm² fixed screw terminal
blocks blocks blocks
Housing material PPE PPE PPE
Approximate weight 40 g 40 g 40 g
Mounting information vertical on rails, side by side vertical on rails, side by side vertical on rails, side by side

MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 —
Jumperred CWBK 7-0802 Cat. No. X766802
(16 poles, 16 A) white CWBK 7-0803 Cat. No. X766803
blue CWBK 7-0804 Cat. No. X766804

70
Analogue
signal converters
• 1.5 kV 3-way input/output/power supply isolation 90
• Fixed value
• Compact size, 6.2 mm thick

92.5
6.2

NOTES BLOCK DIAGRAM


Depth measurements include terminal block and rail clamp
clearance.
(1) r ange 16.8…30 Vdc / 19.2…28.8 Vac
(2) 3-way, IN/OUT/power supply
(3) Version made to order (not kept in stock); contact our sales
office for availability.

Power supply
24 Vac/dc

VERSIONS Cat. No. X756533 Cat. No. X756534 Cat. No. X756535 APPLICATIONS
IN: 0...20 mA / OUT: 0...10 V CWAA 7-0533 (3) Convert and galvanically isolate
IN: 0...20 mA / OUT: 0...20 mA CWAA 7-0534 (3) the main analogue signals into a
IN: 0...20 mA / OUT: 4...20 mA CWAA 7-0535 (3) proportional signal; each model is
designed to convert a single ana-
INPUT TECHNICAL DATA logue signal providing a substantial
Input signal 0...20 mA 0...20 mA 0...20 mA reduction in components and costs,
Input resistance 100 Ω 100 Ω 100 Ω making it the perfect solution for
large plants and applications which
use multiple signals of the same
type, where programmable cards
OUTPUT TECHNICAL DATA would drive up costs. Equipped with
Output signal 0...10 V 0...20 mA 4...20 mA 3-way galvanic separation between
Applicable load >1 kΩ <400 Ω <400 Ω input, output and power supply.
Where multiple output channels are
needed for a single signal source,
GENERAL TECHNICAL DATA multiple converters may be used
Power supply voltage 24 Vac/dc (1) 24 Vac/dc (1) 24 Vac/dc (1) connecting the signal inputs in par-
Power consumption ≤ 13 mA ± 10% ≤ 13 mA ± 10% ≤ 13 mA ± 10% allel (with voltage signals) or in
Accuracy 0.1% at 23°C FS 0.1% at 23°C FS 0.1% at 23°C FS series (with current signals).
Conversion frequency < 30 Hz < 30 Hz < 30 Hz
Temperature coefficient 0.02% / K FS 0.02% / K FS 0.02% / K FS
Isolation 1.5 kVac / 60 s (2) 1.5 kVac / 60 s (2) 1.5 kVac / 60 s (2)
EMC standards EN 61000-6-2, EN 61000-6-4 EN 61000-6-2, EN 61000-6-4 EN 61000-6-2, EN 61000-6-4
Reference Standards IEC 664-1, DIN VDE IEC 664-1, DIN VDE IEC 664-1, DIN VDE
Overvoltage category / Pollution degree III / 2 III / 2 III / 2
Protection degree IP 20 IEC 529, EN60529 IP 20 IEC 529, EN60529 IP 20 IEC 529, EN60529
Operating temperature range -25…+60°C -25…+60°C -25…+60°C
Connection type 2.5 mm² fixed screw terminal 2.5 mm² fixed screw terminal 2.5 mm² fixed screw terminal
blocks blocks blocks
Housing material PPE PPE PPE
Approximate weight 40 g 40 g 40 g
Mounting information vertical on rails, side by side vertical on rails, side by side vertical on rails, side by side
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 —
Jumperred CWBK 7-0802 Cat. No. X766802
(16 poles, 16 A) white CWBK 7-0803 Cat. No. X766803
blue CWBK 7-0804 Cat. No. X766804

71
Analogue
signal converters
• 1.5 kV 3-way input/output/power supply isolation 90
• Fixed value
• Compact size, 6.2 mm thick

92.5
6.2

NOTES BLOCK DIAGRAM


Depth measurements include terminal block and rail clamp
clearance.
(1) r ange 16.8…30 Vdc / 19.2…28.8 Vac
(2) 3-way, IN/OUT/power supply
(3) Version made to order (not kept in stock); contact our sales
office for availability.

Power supply
24 Vac/dc

VERSIONS Cat. No. X756536 Cat. No. X756537 Cat. No. X756538 APPLICATIONS
IN: 4...20 mA / OUT: 0...10 V CWAA 7-0536 Convert and galvanically isolate
IN: 4...20 mA / OUT: 0...20 mA CWAA 7-0537 (3) the main analogue signals into a
IN: 4...20 mA / OUT: 4...20 mA CWAA 7-0538 proportional signal; each model is
INPUT TECHNICAL DATA designed to convert a single ana-
Input signal 4...20 mA 4...20 mA 4...20 mA logue signal providing a substantial
Input resistance 100 Ω 100 Ω 100 Ω reduction in components and costs,
making it the perfect solution for
large plants and applications which
OUTPUT TECHNICAL DATA use multiple signals of the same
Output signal 0...10 V 0...20 mA 4...20 mA type, where programmable cards
Applicable load >1 kΩ <400 Ω <400 Ω would drive up costs. Equipped with
3-way galvanic separation between
GENERAL TECHNICAL DATA input, output and power supply.
Power supply voltage 24 Vac/dc (1) 24 Vac/dc (1) 24 Vac/dc (1) Where multiple output channels are
Power consumption ≤ 13 mA ± 10% ≤ 13 mA ± 10% ≤ 13 mA ± 10% needed for a single signal source,
Accuracy 0.1% at 23°C FS 0.1% at 23°C FS 0.1% at 23°C FS multiple converters may be used
Conversion frequency < 30 Hz < 30 Hz < 30 Hz connecting the signal inputs in par-
Temperature coefficient 0.02% / K FS 0.02% / K FS 0.02% / K FS allel (with voltage signals) or in
Isolation 1.5 kVac / 60 s (2) 1.5 kVac / 60 s (2) 1.5 kVac / 60 s (2) series (with current signals).
EMC standards EN 61000-6-2, EN 61000-6-4 EN 61000-6-2, EN 61000-6-4 EN 61000-6-2, EN 61000-6-4
Reference Standards IEC 664-1, DIN VDE IEC 664-1, DIN VDE IEC 664-1, DIN VDE
Overvoltage category / Pollution degree III / 2 III / 2 III / 2
Protection degree IP 20 IEC 529, EN60529 IP 20 IEC 529, EN60529 IP 20 IEC 529, EN60529
Operating temperature range -25…+60°C -25…+60°C -25…+60°C
Connection type 2.5 mm² fixed screw terminal 2.5 mm² fixed screw terminal 2.5 mm² fixed screw terminal
blocks blocks blocks
Housing material PPE PPE PPE
Approximate weight 40 g 40 g 40 g
Mounting information vertical on rails, side by side vertical on rails, side by side vertical on rails, side by side

MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 —
Jumperred CWBK 7-0802 Cat. No. X766802
(16 poles, 16 A) white CWBK 7-0803 Cat. No. X766803
blue CWBK 7-0804 Cat. No. X766804

72
Passive
galvanic isolators
90 90
• Do not require power supply
• Adapted to loop powered sensors
• 500 V 2-way input/output isolation
• One- and two-channel versions
• Compact size, 6.2 mm thick 92.5 115.5
6.2 6.2

NOTES BLOCK DIAGRAM


Depth measurements include terminal block and rail clamp
clearance.
(1) Input voltage must be greater than that taken from the
formula, where Rb is the resistance of the applied load (see 4 3
figure 1); to make things easier we have provided a graph of
the minimum input voltage based on the variation in applied
5 2
output load (see figure 2); only this value is able to ensure the
maximum output current of 20 mA
(2) 2-way, IN/OUT
(3) Version made to order (not kept in stock); contact our sales
office for availability.

VERSIONS Cat. No. X756526 Cat. No. X756527 APPLICATIONS


Single channel CWPAA 7-0526 Passive galvanic isolators are used
Double channel CWPAA 7-0527 (3) to separate signals generated by
active (i.e. powered) sensors, and
INPUT TECHNICAL DATA are also referred to as current loop
Input signal 1 channel 0…20 mA, 4…20 mA 2 channels 0…20 mA, 4…20 mA or loop powered. The load applied
Input current — — to them must have a resistance of
Input voltage (1) 2.7 + (20 mA x Rb) 2.7 + (20 mA x Rb) below 400 Ω at 20 mA, including
Input resistance 100 Ω 100 Ω the resistance of the conductors.
The input voltage delivered must be
2.7 V higher than the output voltage
OUTPUT TECHNICAL DATA (see note 1).
Output signal 1 channel 0…20 / 4…20 mA, (max 21 2 channels 0…20 / 4…20 mA, (max 21 mA) When these use conditions are
mA) met, passive converters are able
Applicable load <400 Ω with current output <400 Ω with current output to reduce wiring costs for power
supply cables and prevent the need
GENERAL TECHNICAL DATA for external power supplies; they
Power supply voltage — — are not suitable for long connection
Power consumption 12 mA 12 mA wiring since they can heavily influ-
Accuracy 0.1 FS (23°C) 0.1 FS (23°C) ence the output signal level.
Rise time (10..90%) 10 ms 10 ms
Conversion frequency 30 Hz at 3 dB 30 Hz at 3 dB
Temperature coefficient 0.02% FS 0.02% FS
Isolation 1.5 kVac / 60 s (2) 1.5 kVac / 60 s (2)
EMC standards EN 61000-6-2, EN 61000-6-4 EN 61000-6-2, EN 61000-6-4
Reference Standards IED 664-1, DIN VDE IED 664-1, DIN VDE
Overvoltage category / Pollution degree III / 2 III / 2
Protection degree IP 20 IEC 529 EN60529 IP 20 IEC 529 EN60529
Operating temperature range -25…+60°C -25…+60°C
Connection type 1.5 mm² fixed screw terminal blocks 1.5 mm² fixed screw terminal blocks
Housing material Luranyl Luranyl
Approximate weight 35 g 35 g
Mounting information vertical on rails, side by side vertical on rails, side by side
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 —
Jumperred CWBK 7-0802 Cat. No. X766802
(16 poles, 16 A) white CWBK 7-0803 Cat. No. X766803
blue CWBK 7-0804 Cat. No. X766804

fig. 1 fig. 2

73
Monitor module
for alanogue signal
90
• 3-way galvanic separation
• Dip-switch and FDT/DTM software programmable input ranges
• FDT/DTM software programmable output thresholds
• Simplified programming
115.5
6.2

Programming kit X756894

NOTES BLOCK DIAGRAM


Serial interface
The depth measurement includes rail clamp clearance. LED

(1) Version made to order (not kept in stock); contact our


sales office for availability. IN:
+V 5 4 +
(3) 2-way, IN/OUT
+ 5 U 4+ 
OUT: I, U

3  
_ + mA 6 3
_

+ 6 I
+
_ 7 I 2+
_ Pwr
1
+A 7 2 +
8 Power
DC 24 V
- GND _
8 1

VERSIONS Cat. No. X756360 Cat. No. X756894 APPLICATIONS


With screw terminal blocks (standard) LCONALS (1) CWTPR 7-0360 is a “universal”
With spring terminal blocks (1) converter for a wide range of ana-
Programming kit LCONZBUSB (1) logue signals that can be used
INPUT TECHNICAL DATA with the most popular models of
Input signal (1) -30…+30 V -50…+50 mA -5…+5 A analogue sensors on the market.
Input resistance 330 kΩ 30 Ω 10 mΩ Both input ranges and output
Zero / Spam adjustable using FDT/DTM software thresholds can be changed using
FDT/DTM software and a USB inter-
OUTPUT TECHNICAL DATA face.
Threshold adjustment programmable using FDT/DTM software The normally open contacts of the
Contact type 2 NA contacts (solid state relay) two output thresholds are managed
Max. switchable voltage and current 30 Vdc / 100 mA by two solid state relays.
Status display 2 yellow LEDs
Operating mode limit value, window, trend, inversion and memory
GENERAL TECHNICAL DATA
Power supply voltage 24 Vdc (16.8…30 Vdc)
Power consumption 18 mA ± 10% at 24 Vdc
Accuracy 0.1% FS
Data processing 24 Bit
Linearity error < 100 ppm FS
Temperature coefficient <100 ppm/°C
Response time 1...500 ms (adjustable, default 30 ms)
Isolation 2.5 kVac / 60 s (3)
EMC standards EN 50081-2, EN 50082-2
Reference Standards IEC 664-1, DIN VDE
Surge category / Degree of pollution III / 2
Protection degree IP20
Operating temperature range -40…+70°C
Connection type 1.5 mm² fixed screw terminal blocks
Housing material UL94V-0 Noryl
Approximate weight 600 g
Mounting information vertical on rails, side by side
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 —
Jumperred CWBK 7-0802 cat. no. X766802
(16 poles, 16 A) white CWBK 7-0803 cat. no. X766803
blue CWBK 7-0804 cat. no. X766804

74
Programmable
temperature/analogue
converter 90
• For PT100 and PT1000 sensors, thermocouples,
potentiometers
• 2.5 kV 3-way input/output isolation
• 145 DIP-switch selectable input ranges, customisable using 115.5
FDT/DTM software
6.2
• 5 DIP-switch selectable output ranges, customisable using
FDT/DTM software
• Compact size, 6.2 mm thick Programming kit X756894

NOTES BLOCK DIAGRAM Serial interface


RTD
Depth measurements include terminal block and
5 5
5 6 6 5 U,I 4 +
_ LED
6 3
rail clamp clearance. 7 2 +
(1) V ersion made to order (not kept in stock); 8 8 7
8 8 Pwr
1
_ IN:
5 4 +
contact our sales office for availability. OUT: I, U
(2) Input temperature range and output signal R 5 5 5 5
+ _
6 6 5 + 4 _ 6 3
range can be selected using a DIP-switch or 6
6
U,I
3
RTD
Poti
customised using FDT/DTM software. 7
7 _ Pwr
2 +
_ KTY
TC
8 1
(3) 3-way, IN/OUT/power supply 8 8 8 8 7 2 +
Power
DC 24 V
_
TC 6 U,I 4 +
_ 8 1
+
_ 3
Pwr
2 +
_
7 1

VERSIONS Cat. No. X756340 Cat. No. X756894 APPLICATIONS


With screw terminal blocks (standard) LCONTAD (1) CWTPR 7-0340 is a “universal” transducer for a wide range of temperature
With spring terminal blocks (1) sensors that can be used for precise temperature measurement with the
Programming kit LCONZBUSB (1) most popular models of temperature sensors on the market.
INPUT TECHNICAL DATA Measurements can be taken in low and high temperature ranges (e.g. in
Input signal PT100, PT1000, air conditioners) and in process control. The flexibility of the system allows
potentiometer 0…600kΩ it to be used from -200 to 1400°C. With resistive sensors, the connection
Thermocouples types B, C, E, J, K, N, R, S, T method may be based on 2, 3 or 4 wire technologies.
Temperature range -200…+2400°C, based on sensor (2) Both input and output ranges can be changed using FDT/DTM software and
a USB interface.
OUTPUT TECHNICAL DATA
Output signal 0…10 / -10…+10 V, (max. 10.25 V)
0…20 / 4…20 mA, (max 21 mA) (2)
Applicable load >2 kΩ with voltage output
<650 Ω with current output
Warnings Green LED = OK, flashing red LED = error

GENERAL TECHNICAL DATA


Power supply voltage 24 Vdc (16.8...30 Vdc)
Power consumption 18 mA max. at 24 Vdc
Accuracy 10K/span(K) + 0.2% FS (for PT) / 10K/span(K) + 0.4% FS (for TC) Range* S1 S2
Start 7 8 1 2 End 345678
Data processing 24 bit
-200°C 0°C
Linearity error ±0.05% FS (for PT and potentiometer) / ±0.1% FS (for TC) -150°C 50°C
Temperature coefficient <100 ppm/°C -100°C 100°C
Response time 5...500 ms (adjustable, default 30 ms) -50°C 150°C
0°C 200°C
Isolation 2.5 kVac / 60 s (3) 250°C
EMC standards EN 61000-6-2, EN 61000-6-4 Sensor* S1 1 2 3
300°C
Reference Standards IEC 664-1, DIN VDE Pt100 350°C
Pt1000 400°C
Surge category / Degree of pollution III / 2 TE J 450°C
Protection degree IP 20 IEC 529 EN60529 TE K 500°C
Operating temperature range -40…+70°C R 550°C
600°C
Connection type 1.5 mm² fixed screw terminal block Output* S1 4 5 6
650°C
Housing material PA 0 20mA 700°C
Approximate weight 40 g 4 20mA 750°C
0 10V 800°C
Mounting information vertical on rails, side by side ±10V 850°C
MOUNTING ACCESSORIES S1-S2 1-8 off:
900°C
950°C
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB FDT/DTM
1000°C
Mounting rail type according to IEC60715/G32 — *See instruction 1050°C
leaflet
Jumperred CWBK 7-0802 Cat. No. X766802 1100°C
1150°C
white CWBK 7-0803 Cat. No. X766803 1200°C
blue CWBK 7-0804 Cat. No. X766804 1250°C
1300°C
1350°C
1400°C
Switch On

75
Monitor module
for temperature sensor
90
• For PT100 and PT1000 sensors, thermocouples, potentiometers
• 2.5 kV 3-way input/output isolation
• 145 DIP-switch selectable input ranges, customisable using
FDT/DTM software
• Two FDT/DTM software programmable output thresholds 115.5
• Compact size, 6.2 mm thick 6.2

Programming kit X756894

NOTES BLOCK DIAGRAM Serial interface


LED
Depth measurements include terminal block and RTD
5
5
6
5
6 5 4 
+
_ 
6 3 
rail clamp clearance.
_
IN:
7 2 + Pwr
(1) V ersion made to order (not kept in stock); 8 8 7
8 8 1  5 4 +

contact our sales office for availability. 


OUT: I, U
_
(2) T he input temperature range and output 5 5 5 5
5 + 4 + 
_ RTD 6 3
 
R 6 6

thresholds can be selected using a DIP-switch 6 3 Poti

_ Pwr
6 KTY
7 _ 2 +
or customised using FDT/DTM software. 8 8
7
8 8 8 1
TC
7 2 +
(3) 3-way, IN/OUT/power supply Power
DC 24 V
_
8 1
TC 6 4 
+
_ 
+
_ 3 
2
1
_
+

Pwr
7

VERSIONS Cat. No. X756370 Cat. No. X756894 APPLICATIONS


With screw terminal blocks (standard) LCONTLS (1) CWTPR 7-0370 is a “universal” transducer for a wide range of temperature
With spring terminal blocks (1) sensors that can be used for precise temperature measurement with the
Programming kit LCONZBUSB (1) most popular models of temperature sensors on the market.
INPUT TECHNICAL DATA Measurements can be taken in low and high temperature ranges
Input signal PT100, PT1000, (e.g. in air conditioners) and in process control. The flexibility
potentiometer 0…600kΩ of the system allows it to be used from -200 to 1400°C. With resistive sen-
Thermocouples types B, C, E, J, K, N, R, S, T sors, the connection method may be based on 2, 3 or 4 wire technologies.
Temperature range -200…+2400°C, based on sensor (2) Both input ranges and output thresholds can be changed using FDT/DTM
software and a USB interface.
The normally open contacts of the two output thresholds are managed by
OUTPUT TECHNICAL DATA two solid state relays.
Threshold adjustment programmable using FDT/DTM software
Contact type 2 NA contacts (solid state relay)
Max. switchable voltage and current 30 Vdc / 100 mA
Status display 2 yellow LEDs
Operating mode limit value, window, trend, inversion and memory
GENERAL TECHNICAL DATA
Power supply voltage 24 Vdc (16.8...30 Vdc)
Power consumption 18 mA max. at 24 Vdc
Accuracy 10K/span(K) + 0.2% FS (for PT) / 10K/span(K) + 0.4% FS (for TC)
Data processing 24 bit
Linearity error ±0.05% FS (for PT and potentiometer) / ±0.1% FS (for TC)
Temperature coefficient <100 ppm/°C
Response time 5...500 ms (adjustable, default 30 ms)
Isolation 2.5 kVac / 60 s (3)
EMC standards EN 61000-6-2, EN 61000-6-4
Reference Standards IEC 664-1, DIN VDE
Surge category / Degree of pollution III / 2
Protection degree IP 20 IEC 529 EN60529
Operating temperature range -40…+70°C
Connection type 1.5 mm² fixed screw terminal block
Housing material PA
Approximate weight 40 g
Mounting information on rails, side by side
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 —
Jumperred CWBK 7-0802 Cat. No. X766802
white CWBK 7-0803 Cat. No. X766803
blue CWBK 7-0804 Cat. No. X766804

76
Programmable temperature
sensor converters
• Converters for PT100 sensors 79
• 3-way galvanic separation
• 8 programmable input ranges
• 3 programmable output ranges
• Simplified programming 84
• Version with 24-240 Vac/dc power supply 17.5

NOTES BLOCK DIAGRAM


Depth measurements include terminal block and rail clamp
clearance.
(1) Settable using a rotary switch
(2) Settable using a DIP-switch
(3) May also be used with the 2-wire PT100, connecting
terminal blocks 1 and 4 together
(4) range 16.8…30 Vdc / 19.2…28.8 Vac
(5) 3-way, IN/OUT/power supply Power supply
24 Vac/dc

VERSIONS Cat. No. X756816 APPLICATIONS


CWPT 6-0816 The module converts and isolates
signals deriving from three-wire
PT100 (RTD) sensors into a pro-
INPUT TECHNICAL DATA portional analogue signal and is
Input signal Three-wire PT100 (3) programmable in 8 input temper-
Programmable temperatures (1) -50…+50°C (-58…+122°F) ature ranges and into the three
-50…+100°C (-58…+212°F) main standard output signals.
-50…+150°C (-58…+302°F) Configuration is obtained by set-
0…+100°C (+32…+212°F) ting the DIP-switches located on
0…+150°C (+32…+302°F) the side.
0…+200°C (+32…+392°F) The converters are galvanically iso-
0…+300°C (+32…+572°F) lated, which ensures more precise
0…+400°C (+32…+752°F) signal reading, and can be used
Power supply current 0.5 mA both with isolated and non-isolated
sensors.
Two-wire sensors can be used by
connecting terminal blocks 4 and
OUTPUT TECHNICAL DATA 1 together.
Output signal (2) 0…10 V
0…20 / 4…20 mA
Applicable load >1 kΩ with voltage output
<400 Ω with current output

GENERAL TECHNICAL DATA


Power supply voltage 24 Vac/dc (4)
Power consumption ≤ 35 mA ± 10% at 24 Vdc
Accuracy <0.3% FS
Conversion frequency <30 Hz
Temperature coefficient 0.015% / K FS
Isolation 1.5 kVac / 60 s (5)
EMC standards EN 50081-2, EN 50082-2
Reference Standards IEC 664-1, DIN VDE
Overvoltage category / Pollution degree III / 2
Protection degree IP20
Operating temperature range -20…+60°C
Connection type 2.5 mm² fixed screw terminal blocks
Housing material UL94V-0 Noryl
Approximate weight 75 g
Mounting information vertical on rails, side by side

MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 —
Jumperred —
(16 poles, 16 A) white —
blue —

77
Programmable temperature
sensor converters
• Converters for type J and K thermocouple sensors 79
• 3-way galvanic separation
• 8 programmable input ranges
• 3 programmable output ranges
• Simplified programming 84
• Version with 24-240 Vac/dc power supply 17.5

NOTES BLOCK DIAGRAM


Depth measurements include terminal block and rail clamp
clearance.
(1) Settable using a rotary switch
(2) Settable using a DIP-switch
(3) range 16.8…30 Vdc / 19.2…28.8 Vac
(4) 3-way, IN/OUT/power supply

Power supply
24 Vac/dc

VERSIONS Cat. No. X756844 APPLICATIONS


CWTH 6-0844 The module converts and iso-
lates signals deriving from type J
(FeCuNi) or K (NiCrNi) thermocou-
INPUT TECHNICAL DATA ples into a proportional analogue
Input signal FeCuNi (type J) and NiCrNi (type K) thermo- signal and is programmable in eight
couple input temperature ranges and into
compliant with DIN/IEC584-1 the three main standard output sig-
Programmable temperatures (1) -50…+200°C (-58…+392°F) nals. Configuration is obtained by
-50…+350°C (-58 …+662°F) setting the DIP-switches located
0…+200°C (+32…+392°F) on the side.
0…+400°C (+32…+752°F) The converters are galvanically iso-
0…+600°C (+32…+1112°F) lated, which ensures more precise
0…+800°C (+32…+1472°F) signal reading, and can be used
0…+1000°C (+32…+1832°F) both with isolated and non-isolated
0…+1200°C (+32…+2192°F) thermocouples.
Power supply current —

OUTPUT TECHNICAL DATA


Output signal (2) 0…10 V
0…20 / 4…20 mA
Applicable load >1 kΩ with voltage output
<400 Ω with current output

GENERAL TECHNICAL DATA


Power supply voltage 24 Vac/dc (3)
Power consumption ≤ 35 mA ± 10% at 24 Vdc
Accuracy <0.5% FS
Conversion frequency <30 Hz
Temperature coefficient 0.015% / K FS
Isolation 1.5 kVac / 60 s (4)
EMC standards EN 50081-2, EN 50082-2
Reference Standards IEC 664-1, DIN VDE
Overvoltage category / Pollution degree III / 2
Protection degree IP20
Operating temperature range -20…+60°C
Connection type 2.5 mm² fixed screw terminal blocks
Housing material UL94V-0 Noryl
Approximate weight 65 g
Mounting information vertical on rails, side by side

MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 —
Jumperred —
(16 poles, 16 A) white —
blue —

78
Monitor module
for current signal
• For measuring AC currents
• Adjustable threshold value 93
• With transistor and relay output
• 3 kV Input/Output isolation

50
70

NOTES BLOCK DIAGRAM


Depth measurements include terminal block and rail clamp (A) A C Load
clearance. (B) C ontrol threshold
(1) Isolation refers to non-isolated (bare) measurement (C) E xchange output contact
conductor in contact with the wall of the toroid. Using isolated (D) T ransistor-controlled digital input
conductors, the isolation value of the conductor is added to the 24 Vac/dc power supply
isolation value of the converter

VERSIONS Cat. No. XCCIS2 APPLICATIONS


CCIS-2 Inserted into a current circuit, the
card can be used to set (using a
INPUT TECHNICAL DATA precision potentiometer) the desired
Max. measurement current 50 A (AC) current value for the relay or tran-
Max. measurement voltage 600 Vac (1) sistor switch, obtaining a current
Frequency 50…60 Hz threshold above or below which the
Connection of current conductor with Ø 13 mm through cable switch occurs. The cable carrying
the current must be passed through
the module’s toroidal sensor. The
OUTPUT TECHNICAL DATA relay or the transistor switches
Threshold adjustment 2…40 A when the set current threshold is
Hysteresis threshold ± 10% surpassed.
Max. outrush current 100 mA PNP open collector
Output stage “high” 24 V (transistor) and powered relay with I below the threshold
“low” 0 V (transistor) and non-powered relay with I above the threshold
Reaction time 20 ms
GENERAL TECHNICAL DATA
Power supply voltage 24 Vdc ± 10%
Max. power consumption 100 mA
Operating temperature range 0…60°C
Input/output isolation > 3 kVac /60 s
Connection type 2.5 mm² fixed screw terminal blocks
Housing material UL94V-03 polyamide
Approximate weight 100 g
Mounting information vertical on rails, side by side
MOUNTING ACCESSORIES
Mounting rail compliant with IEC60715/TH35 PR/3/AC, PR/3/AS
Mounting rail type according to IEC60715/G32 PR/DIN/AC, PR/DIN/AS, PR/DIN/AL
Jumperred —
(16 poles, 16 A) white —
blue —

79
Current transducer
• For AC and DC current measurements
• Protected from transistors
90
• LED power supply indicator
• 3 programmable output ranges

115.5
6.2

NOTES BLOCK DIAGRAM


Depth measurements include guide rail and front connector
clearance, given together with the product, but not indicated
in the photo. 7 4
IN I U,I OUT+
(1) Do not connect directly to a 400 V line
8 3
IN OUT-
_ 1 + 2

DC 24V

VERSIONS Cat. No. X756540 Cat. No. X756541 Cat. No. X756542 APPLICATIONS
Input 0…1 A WAA 7-0540 Used for measuring an AC or DC
Input 0…5 A WAA 7-0541 current value by means of a “HALL”
Input 0…10 A WAA 7-0542 sensor. The presence of current in a
INPUT TECHNICAL DATA circuit indicates not only that volt-
Input signal 0…1 A AC/DC 0…5 A AC/DC 0…10 A AC/DC age is present, but that the circuit
Max. input voltage 400 V (1) 400 V (1) 400 V (1) is closed and the load connected
Connection of current conductor 1.5 mm2 screw-on terminal 1.5 mm2 screw-on terminal 1.5 mm2 screw-on terminal is active, as well as indicating the
block block block operating conditions of the con-
trol circuit. The module guarantees
OUTPUT TECHNICAL DATA VOLTAGECURRENT
galvanic separation between the
Output signal 0…10 V 0…20 mA / 4…20 mA current conductor and the analogue
Max. output signal 11 V 21 mA output.
Applicable load >1 kΩ <400 Ω
GENERAL TECHNICAL DATA
Power supply voltage 24 Vdc (16.8...30 Vdc) 24 Vdc (16.8...30 Vdc) 24 Vdc (16.8...30 Vdc)
Power consumption 13 mA 13 mA 13 mA
Operating temperature range -25…+60°C -25…+60°C -25…+60°C
Linearity error < 0.1% FS (23°C) < 0.1% FS (23°C) < 0.1% FS (23°C)
Offset error < 0.5% FS (23°C) < 0.5% FS (23°C) < 0.5% FS (23°C)
Temperature coefficient < 150 ppm / K FS < 150 ppm / K FS < 150 ppm / K FS Switch On S1
Response time 150 ms 150 ms 150 ms Input Output 1 2 3 4
Protection degree IP20 IP20 IP20 0-1A 0-10V
Connection type 1.5 mm2 screw-on terminal 1.5 mm2 screw-on terminal 1.5 mm2 screw-on terminal 0-1A 0-20mA
block block block 0-1A 4-20mA
Approximate weight 55 g 55 g 55 g
Mounting information on rails, side by side on rails, side by side on rails, side by side Range WAA7-0540

MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB Switch On S1
Input Output 1 2 3 4
Mounting rail type according to IEC60715/G32 —
0-5A 0-10V
Jumperred CWBK 7-0802 Cat. No. X766802 0-5A 0-20mA
(16 poles, 16 A) white CWBK 7-0803 Cat. No. X766803 0-5A 4-20mA
blue CWBK 7-0804 Cat. No. X766804
Range WAA7-0541

Switch On S1
Input Output 1 2 3 4
0-10A 0-10V
0-10A 0-20mA
0-10A 4-20mA

Range WAA7-0542

80
Current / analogue
converters
• For AC and DC current measurements 94
• Protected from transistors
• LED power supply indicator
• Three available output signals
99
25
Item available until supplies last

NOTES BLOCK DIAGRAM


Depth measurements include guide rail and front connector
clearance, given together with the product, but not indicated
in the photo.

VERSIONS Cat. No. XW000932 APPLICATIONS


Input 0…20 A - Used for measuring an AC or DC
Input 0…50 A SW50VA current value by means of a “HALL”
sensor. The presence of current in a
INPUT TECHNICAL DATA circuit indicates not only that volt-
Input signal 0…50 A AC/DC age is present, but that the circuit
Max. input voltage 380 V is closed and the load connected
Connection of current conductor with Ø 8 mm through cable is active, as well as indicating the
operating conditions of the control
circuit. The module guarantees gal-
vanic separation between current
OUTPUT TECHNICAL DATA VOLTAGECURRENT conductor and analogue output and,
Output signal 0…10 V 0…20 mA / 4…20 mA since it is not connected in series
Max. output signal 11 V 22 mA to the controlled current, it cannot
Applicable load >2 kΩ <500 Ω be damaged by overcurrents or
short-circuits.

GENERAL TECHNICAL DATA


Power supply voltage 24 Vdc ± 10%
Power consumption 60 mA
Operating temperature range 0…55°C
Linearity error < 0.5%
Offset error < 0.5%
Amplification error < 0.2%
Temperature coefficient < 0.02%/K
Transistor immunity 200 V
Response time 10 mS
Protection degree IP20
Connection type 2.5 mm² removable screw terminal blocks
Approximate weight 100 g
Mounting information vertical on rails, side by side

MOUNTING ACCESSORIES
Mounting rail compliant with IEC60715/TH35 PR/3/AC, PR/3/AS
Mounting rail type according to IEC60715/G32 PR/DIN/AC, PR/DIN/AS, PR/DIN/AL
Jumperred —
(16 poles, 16 A) white —
blue —

81
Frequency / analogue
programmable converters
• Programmable frequency range 0...28.8 Khz 79
• 3 programmable analogue output signal ranges
• 2.5 kV 3-way input/output isolation

84
17.5

NOTES BLOCK DIAGRAM


Depth measurements include terminal block and
rail clamp clearance.
(1) range 16.8…30 Vdc / 19.2…28.8 Vac F OUT+
(2) 3 way, IN/OUT/power supply
GND

Shield- OUT-

AC/DC 24V

VERSIONS Cat. No. X756524 APPLICATIONS


CWNFA 6-0524 This module is used to convert a sinusoid or rectangular frequency signal
into a standard analogue signal (e.g. 0…10 V, 0…20 mA or 4…20 mA). A
microprocessor detects the signal and calculates the output value, ensuring
INPUT TECHNICAL DATA extremely high precision and stability. Measurement range is set using
Input signal (range) 0…28.8 kHz settable by DIP switch a DIP switch: the device offers 64 calibrated ranges from 0…100 Hz to
Signal type AC/DC 0.6…30 Vpp 0…28.8 kHz.
Input resistance 50 kΩ
Hysteresis 0.5 Vpp or 5 Vpp settable by DIP switch

OUTPUT TECHNICAL DATA


Output signal 0…10 V, (max. 10.6 V)
0…20 / 4…20 mA, (max 21 mA)
Applicable load >1 kΩ with voltage output
<400 Ω with current output
Ripple < 5 mVeff

GENERAL TECHNICAL DATA


Power supply voltage 24 Vac/dc (1)
Power consumption 20 mA
Accuracy 0.1 FS (23°C)
Linearity error 0.02%
Ripple 0.1%
Setting time (1% precision) 200 ms
Temperature coefficient 70 ppm/K
Isolation 1.5 kVac / 60 s (2)
EMC standards EN 61000-6-2, EN 61000-6-4
Reference Standards IED 664-1, DIN VDE
Surge category III
Degree of pollution 2
Protection degree IP 20 IEC 529 EN60529
Operating temperature range -25…+60°C
Connection type 1.5 mm² fixed screw terminal blocks
Housing material PPE
Approximate weight 70 g
Mounting information vertical on rails, side by side
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 —
Jumperred —
white —
blue —

82
Auxiliary power supply for
sensors and potentiometers
• Stabilised switching converter 90
• IN 16.8…20 Vdc / 9…11 Vdc 60 mA
• Suitable for powering potentiometers and sensors

92.5
6.2 +4 24 Vdc +3
IN OUT
-5 -1
-6 9...11 Vdc -2

9...11 Vdc
NOTES BLOCK DIAGRAM APPLICATION EXAMPLES
Depth measurements include terminal block and rail
clamp clearance.
(1) range 16.8…30 Vdc
+4 24 Vdc +3 +3
+4 24 Vdc 0...10 V
IN OUT
-5 -1 -1
-5
-6 9...11 Vdc -2 10 Vdc 4...20 mA

CWCV 7-6184 POTENTIOMETER


CWCV 7-6184 SIGNAL
POTENZIOMETRO CONVERTITORE
9...11 Vdc CONVERTER
DI SEGNALE

VERSIONS Cat. No. X766184 APPLICATIONS


With screw connection (standard) CWCV 7-6184 A constant voltage is often required in process control in order to supply
With spring connection +3
+4 24 Vdc 0...10 Vpower or reference values. A constant voltage source is very often used
in digital technology, especially with analogue position sensors (linear
-1
INPUT TECHNICAL DATA -5 potentiometers). This is due to their extremely economical and effective
Nominal voltage 10 Vdc
24 Vdc (1) 4...20measurements
mA of absolute position, routes, angles and thicknesses.
Current with max Iout 30 mA at 10 Vdc Moreover, the linear potentiometer requires only one continuous voltage
Safety fuse CWCV T7-6184
1 A (external) and one analogue control or position indicator input.
POTENZIOMETRO CONVERTITORE
DI SEGNALE

OUTPUT TECHNICAL DATA


Voltage 10 Vdc (9…11 Vdc adjustable)
Maximum current 60 mA
Permanent current 60 mA
Load regulation < 1%
Ripple at nominal U-I ≤ 50 mVpp
Protection against short circuit/overload yes
Output signal Yellow LED Power OK
Parallel connection possible with external diode
GENERAL TECHNICAL DATA
Operating temperature range -25...+60°C
Input/output isolation 50 Vac / 60 s
Protection degree IP 20 IEC529, EN60529
Electromagnetic compatibility EN 50081-1, EN 50082-2, EN 61000-3-2
Transistor immunity EN61000-4-2, EN61000-4-4
Connection type 1.5 mm2 screw/1.5 mm2 spring
Housing material UL94V-0 Noryl
Approximate weight 35 g
Mounting information vertical on rails, side by side
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 —
Jumperred CWBK 7-0802 Cat. No. X766802
white CWBK 7-0803 Cat. No. X766803
blue CWBK 7-0804 Cat. No. X766804

83
Signal inverters
NPN and PNP
• Converts NPN sensors to PNP and vice versa
• Reduced overall dimensions 77

12
45

NOTES BLOCK DIAGRAM


(1) range 17…30 Vdc

 

 

VERSIONS Cat. No. XNPNPNP APPLICATIONS


CI-NPN/PNP Converts PNP sensor signals to NPN and vice versa.
It is able to adapt all sensors on the market to any PLC input regardless
of output polarity, and it is highly useful in maintenance operations where
INPUT TECHNICAL DATA the correct replacement sensor is unavailable.
Input voltage 24 Vdc (1)
Max current 200 mA
Max. frequency 120 kHz

GENERAL TECHNICAL DATA


Current set to OFF —
EMC standards EN 61000-6-2, EN 61000-6-4
Reference Standards IEC 664-1, DIN VDE
Surge category II
Degree of pollution 2
Protection degree IP 20 IEC 529 EN60529
Operating temperature range 0...55°C
Connection type 2.5 mm² fixed screw terminal blocks
Housing material UL94V-0 polyamide
Approximate weight 20 g
Mounting information vertical on rails, side by side

MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AS
Mounting rail type according to IEC60715/G32 PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
Jumperred —
white —
blue —

CONNECTION EXAMPLES

PNP sensor
  load
 
 
  
Conversion from PNP to NPN  




NPN sensor
  load
 

  
Conversion from NPN to PNP  


 

84
These tables are used for quickly identifying items and verifying whether all of the product’s technical details satisfy the set requirements.

Number of Output
Input rated voltage Notes Type Cat. No. Page
relays type/no. of contacts contact current
1 12 Vdc 1 SC 10A (1) CM1C012 XCM1C012 88
1 12 Vdc 2 SC 5A (1) CM2C012 XCM2C012 89
1 12 Vac 1 SC 10A (1) CM1A012 XCM1A012 91
1 12 Vac 2 SC 5A (1) CM2A012 XCM2A012 92
1 12 Vac/dc 1 SC 6A (1) CWRE7-0848 X766848 95
1 24 Vdc 1 NA 5A (2) RFA024D XRFA024D 86
1 24 Vdc 1 SC 16A (1) RE1024D XRE1024D 86
1 24 Vdc 1 SC 16A (2) RF1024D XRF1024D 86
1 24 Vdc 1 SC 12A (1) CM1C024 XCM1C024 88
1 24 Vdc 1 SC 12A (1) RE1824D XRE1824D 86
1 24 Vdc 1 SC 12A (2) RF1824D XRF1824D 86
1 24 Vdc 2 SC 8A (1) CM2C024 XCM2C024 89
1 24 Vdc 4 SC 3A (1) CM4C024 XCM4C024 90
1 24 Vac/dc 1 SC 6A (1) CWRE7-0842 X766842 95
1 24 Vac/dc 1 SC 6A (2) (3) CKR16 XCKR16 94
1 24 Vac/dc 2 SC 8A (1) RE2024D XRE2024D 87
2 24 Vac/dc 2 NA 5A (2) CKR25 XCKR25 94
1 24 Vac 1 SC 12A (1) CM1A024 XCM1A024 91
1 24 Vac 2 SC 8A (1) CM2A024 XCM2A024 92
1 48 Vdc 1 SC 10A (1) CM1C048 XCM1C048 88
1 48 Vdc 2 SC 5A (1) CM2C048 XCM2C048 89
1 48 Vac/dc 1 SC 6A (1) CWRE7-0845 X766845 95
1 110 Vdc 1 SC 10A (1) CM1C110 XCM1C110 88
1 110 Vdc 2 SC 5A (1) CM2C110 XCM2C110 89
1 110...120 Vac/dc 1 SC 6A (1) CWRE7-0846 X766846 95
1 120 Vac 1 SC 10A (1) CM1A120 XCM1A120 91
1 120 Vac 2 SC 5A (1) CM2A120 XCM2A120 92
1 230 Vac 1 SC 6A (1) CWRE7-0847 X766847 95
1 230 Vac 1 SC 10A (1) CM1A230 XCM1A230 91
1 230 Vac 2 SC 5A (1) CM2A230 XCM2A230 92

Notes
(1) version with pluggable relay
(2) version with fixed relay
(3) safety fuse on contact
(4) no light alarm and protection diode

85
Single relay modules
R series
77 77 77

12 16.4 16.4
52 70 70

NOTES BLOCK DIAGRAM


(1) Relay make and model are not final and may be replaced
without notice. The technical details shown are to be
considered typical.
(2) Version made to order (not kept in stock); contact our sales
office for availability.

VERSIONS Cat. No. XRFA024D Cat. No. XR_1824D Cat. No. XR_1024D
Pluggable relay – RE1824D RE1024D
Fixed relay RFA024D (2) RF1824D RF1024D (2)

INPUT TECHNICAL DATA


Nominal voltage 24 Vdc ± 10% 24 Vdc ± 10% 24 Vdc ± 10%
Power consumption (1 channel) 15 mA ± 10% 22 mA ± 10% 27 mA ± 10%
Turn ON time 15 ms 15 ms 15 ms
Turn OFF time 5 ms 5 ms 5 ms
Protection circuit damping diode damping diode damping diode
OUTPUT TECHNICAL DATA
Contact type 1 NA AgSnO2 1 exchange AgSnO2 1 exchange AgSnO2
Nominal current (resistive load) 5 A / 250 Vac 12 A / 250 Vac 16 A / 250 Vac
Max. cut-off capacity 5A 12 A 16 A
Max. fuse current — — —
GENERAL TECHNICAL DATA
Operating temperature range –10...+50°C –10...+50°C –10...+50°C
Coil isolation / contacts 2.5 kVac / 60 s 2.5 kVac / 60 s 2.5 kVac / 60 s
Isolation between output terminal blocks 0.5 kVac / 60 s (between open contact poles) 0.5 kVac / 60 s (between open contact poles) 0.5 kVac / 60 s (between open contact poles)
Protection degree IP 00 IEC529, EN60529 IP 00 IEC529, EN60529 IP 00 IEC529, EN60529
Overvoltage category / Pollution degree III / 2 III / 2 III / 2
Reference Standards IEC 664-1, DIN VDE 0110.1 IEC 664-1, DIN VDE 0110.1 IEC 664-1, DIN VDE 0110.1
Power/status indicator Green LED Green LED Green LED
Connection type AWG26-14 2.5 mm² screw clamp terminal AWG26-14 2.5 mm² screw clamp terminal AWG26-14 2.5 mm² screw clamp terminal
blocks blocks blocks
Housing material UL94V-0 plastic UL94V-0 plastic UL94V-0 plastic
Approximate weight 30 g 44 g 44 g
Mounting information on rails, side by side on rails, side by side on rails, side by side
MOUNTING ACCESSORIES
Mounting rail compliant with IEC60715/TH35 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
Spare part relay (1) Cat. No. 8904000 Cat. No. 8904001 Cat. No. 8904058
Jumperblack — — —

86
Single relay modules
R series
93

26
75

NOTES BLOCK DIAGRAM


(1) Relay make and model are not final and may be replaced
without notice. The technical details shown are to be
considered typical.
(2) Product made to order (not kept in stock).

VERSIONS Cat. No. XRE2024D


Pluggable relay RE2024D
Fixed relay –

INPUT TECHNICAL DATA


Nominal voltage 24 Vac / dc ± 10%
Power consumption (1 channel) 22 mA ± 10%
Turn ON time 15 ms
Turn OFF time 5 ms
Protection circuit damping diode
OUTPUT TECHNICAL DATA
Contact type 2 exchanges AgSnO2
Nominal current (resistive load) 8 A / 250 Vac
Max. cut-off capacity 8A
Max. fuse current —
GENERAL TECHNICAL DATA
Operating temperature range –10...+50°C
Coil isolation / contacts 2.5 kVac / 60 s
Isolation between output terminal blocks 0.5 kVac / 60 s (between open contact poles)
Protection degree IP 00 IEC529, EN60529
Overvoltage category / Pollution degree III / 2
Reference Standards IEC 664-1, DIN VDE 0110.1
Power/status indicator Green LED
Connection type AWG26-14 2.5 mm² screw clamp terminal
blocks
Housing material UL94V-0 plastic
Approximate weight 76 g
Mounting information on rails, side by side
MOUNTING ACCESSORIES
Mounting rail compliant with IEC60715/TH35 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
Spare part relay (1) Cat. No. 8904002
Jumperblack —

87
Single relay modules
CM series
• Pluggable relay
• Installation on omega rail or panel using centre screw
• Compact dimensions
• Cross and slotted screw 75
• Available plug-in jumper for potential distribution

16
68 Jumper available

NOTES BLOCK DIAGRAM


Measurements include rail clamp clearance.
(1) Relay make and model are not final and may be replaced
without notice. The technical details shown are to be
considered typical.
(2) Versions without indicators or safety circuits are available
upon request; to order, add the suffix “Z” to the Cat. No.
(e.g. XCM1C024Z).
(3) Gold contact versions are available upon request; to order,
add the suffix “U” to the Cat. No. (e.g. XCM1C024U).

VERSIONS Cat. No. XCM1C012 Cat. No. XCM1C024 Cat. No. XCM1C048 Cat. No. XCM1C110
12 Vdc CM1C012
24 Vdc CM1C024
48 Vdc CM1C048
110 Vdc CM1C0110
INPUT TECHNICAL DATA
Nominal voltage 12 Vdc ±10% 24 Vdc ±10% 48 Vdc ±10% 110 Vdc ±10%
Power consumption (1 channel) 44 mA ±10% 22 mA ±10% 12 mA ±10% 11 mA ±10%
Turn ON time 15 ms 15 ms 15 ms 15 ms
Turn OFF time 5 ms 5 ms 5 ms 20 ms
Protection circuit damping diode (2)
OUTPUT TECHNICAL DATA
Contact type 1 exchange AgSnO2 (3)
Nominal current (resistive load) 12 A / 250 Vac
Max. cut-off capacity 12 A
Max. fuse current —
GENERAL TECHNICAL DATA
Operating temperature range –10...+50°C
Coil isolation / contacts 4 kVac / 60 s
Isolation between output terminal blocks 1 kVac / 60 s (between open contact poles)
Protection degree IP 20 IEC 529, EN60529
Overvoltage category / Pollution degree III / 2
Reference Standards IEC 664-1, DIN VDE 0110.1
Power/status indicator Green LED (2)
Connection type AWG26-14 2.5 mm² screw clamp terminal blocks
Housing material UL94V-0 plastic
Approximate weight 54 g
Mounting information rail, side by side or panel using centre screw

MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 —
Spare part relay (1) Cat. No. 8904039 Cat. No. 8904001 Cat. No. 8904008 Cat. No. 8904047
Jumperblack Cat. No. XCMB16B
white —
blue —

Jumper

88
Single relay modules
CM series
• Pluggable relay
• Installation on omega rail or panel using centre screw
• Compact dimensions
• Cross and slotted screw 75
• Available plug-in jumper for potential distribution

16
75 Jumper available

NOTES BLOCK DIAGRAM


Measurements include rail clamp clearance.
(1) Relay make and model are not final and may be replaced
without notice. The technical details shown are to be
considered typical.

VERSIONS Cat. No. XCM2C012 Cat. No. XCM2C024 Cat. No. XCM2C048 Cat. No. XCM2C110
12 Vdc CM2C012
24 Vdc CM2C024
48 Vdc CM2C048
110 Vdc CM2C0110
INPUT TECHNICAL DATA
Nominal voltage 12 Vdc ±10% 24 Vdc ±10% 48 Vdc ±10% 110 Vdc ±10%
Power consumption (1 channel) 44 mA ±10% 22 mA ±10% 24 mA ±10% 11 mA ±10%
Turn ON time 15 ms 15 ms 15 ms 15 ms
Turn OFF time 5 ms 5 ms 5 ms 20 ms
Protection circuit damping diode
OUTPUT TECHNICAL DATA
Contact type 2 exchanges AgSnO2
Nominal current (resistive load) 8 A / 250 Vac
Max. cut-off capacity 8A
Max. fuse current —
GENERAL TECHNICAL DATA
Operating temperature range –10...+50°C
Coil isolation / contacts 4 kVac / 60 s
Isolation between output terminal blocks 1 kVac / 60 s (between open contact poles)
Protection degree IP 20 IEC 529, EN60529
Overvoltage category / Pollution degree III / 2
Reference Standards IEC 664-1, DIN VDE 0110.1
Power/status indicator Green LED
Connection type AWG26-14 2.5 mm² screw clamp terminal blocks
Housing material UL94V-0 plastic
Approximate weight 67 g
Mounting information rail, side by side or panel using centre screw

MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 —
Spare part relay (1) Cat. No. 8904040 Cat. No. 8904002 Cat. No. 8904009 Cat. No. 8904054
Jumperblack Cat. No. XCMB16B
white —
blue —

Jumper

89
Single relay modules
CM series
• Pluggable relay
• Installation on omega rail or panel using centre screw
• Compact dimensions
• Cross and slotted screw 75
• Available plug-in jumper for potential distribution

27
68

NOTES BLOCK DIAGRAM


Measurements include rail clamp clearance.
(1) Relay make and model are not final and may be replaced
without notice. The technical details shown are to be
considered typical

VERSIONS Cat. No. XCM4C024


12 Vdc
24 Vdc CM4C024
48 Vdc
110 Vdc
INPUT TECHNICAL DATA
Nominal voltage 24 Vdc ±10%
Power consumption (1 channel) 38 mA ±10%
Turn ON time 20 ms
Turn OFF time 20 ms
Protection circuit damping diode
OUTPUT TECHNICAL DATA
Contact type 4 exchanges AgSnO2
Nominal current (resistive load) 3 A / 250 Vac
Max. cut-off capacity 3A
Max. fuse current —
GENERAL TECHNICAL DATA
Operating temperature range –10...+50°C
Coil isolation / contacts 4 kVac / 60 s
Isolation between output terminal blocks 1 kVac / 60 s (between open contact poles)
Protection degree IP 20 IEC 529, EN60529
Overvoltage category / Pollution degree III / 2
Reference Standards IEC 664-1, DIN VDE 0110.1
Power/status indicator Green LED
Connection type AWG26-14 2.5 mm² screw clamp terminal blocks
Housing material UL94V-0 plastic
Approximate weight
Mounting information rail, side by side or panel using centre screw

MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 —
Spare part relay (1) Cat. No. 8904030
Jumperblack Cat. No. XCMB27B
white —
blue —

Jumper

90
Single relay modules
CM series
• Pluggable relay
• Installation on omega rail or panel using centre screw
• Compact dimensions
• Cross and slotted screw 75
• Available plug-in jumper for potential distribution

16
Jumper available
68

NOTES BLOCK DIAGRAM


Measurements include rail clamp clearance.
(1) Relay make and model are not final and may be replaced
without notice. The technical details shown are to be
considered typical
(2) Version made to order (not kept in stock); contact our sales
office for availability.

VERSIONS Cat. No. XCM1A012 Cat. No. XCM1A024 Cat. No. XCM1A120 Cat. No. XCM1A230
12 Vdc CM1A012 (2)
24 Vdc CM1A024
120 Vdc CM1A120 (2)
230 Vdc CM1A230
INPUT TECHNICAL DATA
Nominal voltage 12 Vac ±10% 24 Vac ±10% 120 Vac ±10% 230 Vac ±10%
Power consumption (1 channel) 95 mA ±10% 48 mA ±10% 10.5 mA ±10% 6 mA ±10%
Turn ON time 15 ms 15 ms 15 ms 15 ms
Turn OFF time 10 ms 10 ms 10 ms 10 ms
Protection circuit —
OUTPUT TECHNICAL DATA
Contact type 1 exchange AgSnO2
Nominal current (resistive load) 12 A / 250 Vac
Max. cut-off capacity 12 A
Max. fuse current —
GENERAL TECHNICAL DATA
Operating temperature range –10...+50°C
Coil isolation / contacts 4 kVac / 60 s
Isolation between output terminal blocks 1 kVac / 60 s (between open contact poles)
Protection degree IP 20 IEC 529, EN60529
Overvoltage category / Pollution degree III / 2
Reference Standards IEC 664-1, DIN VDE 0110.1
Power/status indicator Green LED
Connection type AWG26-14 2.5 mm² screw clamp terminal blocks
Housing material UL94V-0 plastic
Approximate weight 54 g
Mounting information rail, side by side or panel using centre screw

MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 —
Spare part relay (1) Cat. No. 8904016 Cat. No. 8904048 Cat. No. 8904049 Cat. No. 8904050
Jumperblack XCMB16B
white —
blue —

Jumper

91
Single relay modules
CM series
• Pluggable relay
• Installation on omega rail or panel using centre screw
• Compact dimensions
• Cross and slotted screw 75
• Available plug-in jumper for potential distribution

16
75 Jumper available

NOTES BLOCK DIAGRAM


Measurements include rail clamp clearance.
(1) Relay make and model are not final and may be replaced
without notice. The technical details shown are to be
considered typical.
(2) Version made to order (not kept in stock); contact our sales
office for availability.

VERSIONS Cat. No. XCM2A012 Cat. No. XCM2A024 Cat. No. XCM2A120 Cat. No. XCM2A230
12 Vac CM2A012 (2)
24 Vac CM2A024
120 Vac CM2A120 (2)
230 Vac CM2A230
INPUT TECHNICAL DATA
Nominal voltage 12 Vac ±10% 24 Vac ±10% 120 Vac ±10% 230 Vac ±10%
Power consumption (1 channel) 95 mA ±10% 48 mA ±10% 10.5 mA ±10% 6 mA ±10%
Turn ON time 15 ms 15 ms 15 ms 15 ms
Turn OFF time 10 ms 10 ms 10 ms 10 ms
Protection circuit —
OUTPUT TECHNICAL DATA
Contact type 2 exchanges AgSnO2
Nominal current (resistive load) 8 A / 250 Vac
Max. cut-off capacity 8A
Max. fuse current —
GENERAL TECHNICAL DATA
Operating temperature range –10...+50°C
Coil isolation / contacts 4 kVac / 60 s
Isolation between output terminal blocks 1 kVac / 60 s (between open contact poles)
Protection degree IP 20 IEC 529, EN60529
Overvoltage category / Pollution degree III / 2
Reference Standards IEC 664-1, DIN VDE 0110.1
Power/status indicator Green LED
Connection type AWG26-14 2.5 mm² screw clamp terminal blocks
Housing material UL94V-0 plastic
Approximate weight 67 g
Mounting information rail, side by side or panel using centre screw

MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 —
Spare part relay (1) Cat. No. 8904017 Cat. No. 8904055 Cat. No. 8904056 Cat. No. 8904057
Jumperblack Cat. No. XCMB16B
white —
blue —

Jumper

92
“CK” series interface system

This series of automation interfaces comprises a range of electromechanical relay modules, solid state
relays and passive interfaces in modular cases just 6 mm thick.
All of these products are housed in the new CK module (also available as a component holder module)
which, with its 6 2.5 mm² spring terminal blocks and 4 contacts for insertion of the innovative “easy
bridge”, makes it possible to create different, effective compositions with a significant saving in terms
of space and time.

The range currently comprises a series of products which can all be assembled together:

• Individual electromechanical relays with a single 6 A exchange protected by a replaceable fuse, frontal
status LED, AC/DC input and positive or negative coil common. NO OK
• Double electromechanical relays with a 5 A NO contact, frontal status LED, AC/DC input and positive
or negative coil common.
• Individual solid state relays for 5 A negative common loads protected by a replaceable fuse, frontal
status LED and positive or negative input common.
• Double solid state relays for 12-24 Vdc 2.5 A negative common loads with frontal status LED and
positive or negative input common. 1
• Cards with feed-through diode or common anode or cathode.
• Lamp testing modules.
• Distribution modules for common indication and distribution via PTC/CK/42 jumper.

How to create an interface with the CK system:

• Mount the selected relay modules onto the rail. NO


• THE common input and output power supply potentials can be interconnected using OK
PTC/CK/42 quick connector jumpers. 2
• For the power supply to relay module inputs and outputs, it is advised to use the CKF- - module which
allows for connection using 24 A spring terminal blocks (2.5mm2, AWG26-14), distributing the power
to the inputs and outputs of the adjacent modules using quick connection jumpers; the CTF- - module
may be mounted as the primary module or in a central position in order to divide the current in the
jumper into two branches, reducing voltage drops and heating; the CTF- - is available with an LED
voltage indicator on the input and output for different voltages.
• THE final module must always be protected with the CK/PT terminal wall to ensure protection degree
IP20.
• Each relay module comes with technical data sheets and a connection diagram; terminal blocks may
be marked with NU0851 series tags, to be applied with a pen, plotter or with the Cabur Jet printer. 3
• Relay input/output power supply cables can be connected directly to relay terminal blocks, connecting
two cables (power supply and load input) with a cross section of less than 2.5mm2 into one terminal
block, which reduces the applicable current and the number of relay modules that may be powered;
this problem is resolved using the supply distribution module as illustrated in point three.

Easy Bridge System

The PTC/CK/42 quick connector jumper comprises a 42 pole comb with capacity for a maximum 4
current of 32 A, limited to the capacity of the 24 A terminal block, therefore in a plug-in jumper of e.g.
11 poles (1 common and 10 distribution) 2.4 A can be distributed per pole.
The jumper is designed to be extremely simple and economical, with an innovative terminal block that
isolates the jumper and a connection system that is not only fast, but requires no specific tools to use.

• the jumper should be divided as required simply using nail clippers, close to the pole to maintain a
protection degree IP20 (1 and 2),
• insert the jumper into the relevant terminal block hole (3),
• use a screwdriver to push the jumper in until it locks. The jumper will now be completely isolated (4),
• to remove the jumper simply insert a screwdriver into the jumper slot, lift it and slide it out (5 and 6). 5

93
Single relay modules
CKR series
91 91
• Replaceable contact safety fuse
• Positive or negative common AC/DC input
• Frontal status LED, reverse polarity protection, coil damp-
ing diode
• Width 6 mm 100 100
• Available plug-in jumper for potential distribution 6 6

NOTES BLOCK DIAGRAM


(1) The XCKR16 module is equipped with a 7.5 A automobile-
type quick replaceable contact safety fuse, connected in series
to contact 11 (common pole); this can be replaced with a fuse
of a lesser value to provide compatibility with the load and/or
wiring current; a fuse greater than 7.5 A does not protect the
contact. The fuse used is suitable for SELV ≤ 50 Vac and ≤ 75
Vdc voltages; if used with greater voltages it will not guarantee
cut-off capability and safe operation.
(2) Product made to order (not kept in stock).
(3) the final module must always be protected with the CK/PT
terminal wall to ensure protection degree IP20.

VERSIONS Cat. No. XCKR16 Cat. No. XCKR25


1 channel CKR16 —
2 channels — CKR25 (2)

INPUT TECHNICAL DATA


Nominal voltage 24 Vac/dc ± 10% 24 Vac/dc ±10%
Power consumption (1 channel) ≤15 mA ± 10% at 24 Vdc ≤13 mA ±10% at 24 Vdc
Turn ON time 5 ms 5 ms
Turn OFF time 10 ms 10 ms
Protection circuit damping diode damping diode
OUTPUT TECHNICAL DATA
Contact type 1 exchange AgSnO2 2 NA AgSnO2
Nominal current (resistive load) 6 A / 250 Vac 5 A / 250 Vac
Max. cut-off capacity 30 A 30 A
Max. fuse current — —
GENERAL TECHNICAL DATA
Operating temperature range -20…+60°C -20…+60°C
Coil isolation / contacts 3 kVac / 60 s 3 kVac / 60 s
Isolation between output terminal blocks — —
Protection degree IP 20 IEC529, EN60529 IP 00 IEC529, EN60529
Overvoltage category / Pollution degree II / 2 II / 2
Reference Standards IEC 664-1, DIN VDE 0110.1 IEC 664-1, DIN VDE 0110.1
Power/status indicator Green LED Green LED
Connection type Fixed AWG26-14 2.5 mm2 spring terminal Fixed AWG26-14 2.5 mm2 spring terminal
blocks blocks
Housing material UL94V-0 polyamide UL94V-0 polyamide
Approximate weight 40 g 43 g
Mounting information vertical on rails, side by side vertical on rails, side by side

MOUNTING ACCESSORIES
Mounting rail compliant with IEC60715/TH35 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 — —
Spare part relay (1) — —
Jumper— Cat. No. PTCCK42 (42 poles) Cat. No. PTCCK42 (42 poles)
Marking tag neutral Cat. No. NU0851 Cat. No. NU0851
End section Cat. No. XCKPT Cat. No. XCKPT

94
Single relay modules
CKR series
• Pluggable relay
• Frontal status LED
• Width 6.2 mm 89
• Available plug-in jumper for potential distribution

77
6.2

NOTES APPLICATIONS BLOCK DIAGRAM


Measurements include rail clamp clearance. The CWRE series is designed for signal switching and is
(1) Made to order (not kept in stock), for information contact our equipped with a pluggable relay to facilitate maintenance
sales office. procedures. They can also be used in parallel from both the
(2) Relay make and model are not final and may be replaced input and output sides using a specific plug-in jumper.
without notice. The technical details shown are to be
considered typical.

VERSIONS Cat. No. X766848 Cat. No. X766842 Cat. No. X766845 Cat. No. X766846 Cat. No. X766847
12 Vac/dc (1) CWRE7-0848 (1)
24 Vac/dc CWRE7-0842
48 Vac/dc (1) CWRE7-0845 (1)
115 Vac/dc CWRE7-0846
230 Vac/dc CWRE7-0847
INPUT TECHNICAL DATA
Nominal voltage 12 Vac/dc ±10% 24 Vac/dc ±10% 48 Vac/dc ±10% 115 Vac/dc ±10% 230 Vac/dc ±10%
Power consumption (1 channel) 10 mA ±10% 7 mA ±10% 5 mA ±10% 4 mA ±10% 4 mA ±10%
Turn ON time 8 ms 8 ms 7 ms 8 ms 8 ms
Turn OFF time 5 ms 5 ms 7 ms 13 ms 13 ms
Protection circuit damping diode, reverse polarity protection diode jumper
OUTPUT TECHNICAL DATA
Contact type 1 exchange AgSnO2 (3)
Nominal current (resistive load) 6 A / 250 Vac ; 6 A / 30 Vdc
Max. cut-off capacity DC 13: 24 V / 1A; 115V / 200 mA; 230 V / 100 mA
Max. fuse current —
GENERAL TECHNICAL DATA
Operating temperature range -40...+70°C
Coil isolation / contacts 4 kVac / 60 s
Isolation between output terminal blocks 1 kVac / 60 s (between open contact poles)
Protection degree IP 20 IEC 529, EN60529
Overvoltage category / Pollution degree III / 2
Reference Standards IEC 664.1, DIN VDE 0110.1
Power/status indicator Green LED
Connection type AWG26-14 2.5 mm² screw clamp terminal blocks
Housing material UL94V-0 plastic
Approximate weight 35 g
Mounting information on rails, side by side
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 —
Spare part relay (2) Cat. No. 8904027
Cross connection bridge black —
white —
blue CWBK7-0813 (Cat. No. X766813) (20 poles)
Marking tag neutral Cat. No. NUPUTUK50
End section —

95
These tables are used for quickly identifying items and verifying whether all of the product’s technical details satisfy the set requirements.

Number of Output
Nominal voltage input nominal current Notes Type Cat. No. Page
relays type/no. of contacts
4 24 Vdc SPDT 12 A (1) (4) R41E24 XR041E24 97
8 24 Vdc SPDT 12 A (1) (4) R81E24 XR081E24 97
16 24 Vdc SPDT 12 A (1) (4) R161E24 XR161E24 97
4 24 Vac/dc SPDT 12 A (1) (6) R41EAD XR041EAD 98
8 24 Vac/dc SPDT 12 A (1) (6) R81EAD XR081EAD 98
16 24 Vac/dc SPDT 12 A (1) (6) R161EAD XR161EAD 98
4 24 Vac/dc SPDT 12 A (1) (6) (8) R41U24F XR041U24F 99
8 24 Vac/dc SPDT 12 A (1) (6) (8) R81U24F XR081U24F 99
16 24 Vac/dc SPDT 12 A (1) (6) (8) R161U24F XR161U24F 99
4 24 Vdc DPDT 8A (1) (4) R42E24 XR042E24 100
8 24 Vdc DPDT 8A (1) (4) R82E24 XR082E24 100
16 24 Vdc DPDT 8A (1) (4) R162E24 XR162E24 100
4 24 Vac/dc DPDT 8A (1) (6) R42EAD XR042EAD 101
8 24 Vac/dc DPDT 8A (1) (6) R82EAD XR082EAD 101
16 24 Vac/dc DPDT 8A (1) (6) R162EAD XR162EAD 101
8 24 Vac/dc SPDT 12 A (1) (6) (9) (10) RMP081CM XRMP081CM 102
4 110 Vdc/120 Vac SPDT 10 A (1) (6) R41E11A XRO41E1A 103
4 24 Vac/dc SPDT 8A (2) (6) CR4-1 XCR41 103
4 24 Vac/dc SPDT 8A (1) (6) CRE4-1 XCRE41 103
8 24 Vac/dc SPST(NO) 8A (1) (6) CRE8-1 XCRE81 103
8 24 Vac/dc SPST(NO) 8A (2) (6) CR8-1 XCR81 103
4 24 Vac/dc DPDT 8A (2) (6) CR4-2SC XCR42SC 104
4 24 Vac/dc DPDT 8A (1) (6) CRE4-2SC XCRE42SC 123

Notes
(1) pluggable relay version (6) universal common, negative DC control, positive DC, AC
(2) fixed relay version (7) control via connector
(3) base without relay (8) safety fuse on contact
(4) negative common, positive control (9) with test button
(5) positive common, negative control (10) with test switch

96
Multi-relay modules
• Control with direct current voltages
• Operation with negative common
• LED status indicator
• Pluggable relay 93 93 93

70 137 250

75 75 75

NOTES BLOCK DIAGRAM


Measurements include rail clamp clearance.
(1) Relay make and model are not final and may
be replaced without notice. The technical
details shown are to be considered typical

4 relay module
VERSIONS Cat. No. XR041E24 Cat. No. XR081E24 Cat. No. XR161E24
4 relay module R41E24
8 relay module R81E24
16 relay module R161E24
INPUT TECHNICAL DATA
Nominal voltage 24 Vdc ± 10%
Power consumption (1 channel) 22 mA ± 10%
Turn ON time 15 ms
Turn OFF time 5 ms
Protection circuit damping diode, reverse polarity protection diode

OUTPUT TECHNICAL DATA


Contact type 1 exchange AgSnO2 81 84 82
Nominal load (resistive) 12 A / 250 Vac
Max. cut-off capacity 12 A 8 relay module
Max. fuse current —

GENERAL TECHNICAL DATA


Operating temperature range –10...+50°C
Coil isolation / contacts 2.5 kVac / 60 s
Isolation between output terminal blocks 1 kVac / 60 s (between open contact poles)
Protection degree IP 20 IEC 529, EN60529
Surge category/degree of pollution III / 2
Reference Standards IEC 664-1, DIN VDE 0110.1
Power/status indicator Green LED / Yellow LED
Connection type 2.5 mm2 fixed screw terminal blocks and FLAT connector
Housing material UL94V-0 plastic
Approximate weight 188 g 342 g 657 g
Mounting information on rails, side by side
16 relay module
MOUNTING ACCESSORIES
Mounting rail compliant with IEC60715/TH35 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
Spare part relay (1) Cat. No. 8904001
Jumperred —
white —
blue —

97
Multi-relay modules
• Control with both alternating and direct current
voltages
• Operation with both positive and negative
common
• LED status indicator 93 93 93
• Pluggable relay

70 137 250

75 75 75

NOTES BLOCK DIAGRAM


Measurements include rail clamp clearance. POWER SUPPLY COMPATIBILITY
(1) Relay make and model are not final and may A1 = + A2 = – negative common
be replaced without notice. The technical
details shown are to be considered typical A1 = – A2 = + positive common
(2) Product made to order (not kept in stock). A1 = ~ A2 = ~ AC power supply

4 relay module
VERSIONS Cat. No. XR041EAD Cat. No. XR081EAD Cat. No. XR161EAD
4 relay module R41EAD
8 relay module R81EAD
16 relay module R161EAD
INPUT TECHNICAL DATA
Nominal voltage 24 Vac/dc ± 10%
Power consumption (1 channel) 22 mA ± 10%
Turn ON time 15 ms
Turn OFF time 5 ms
Protection circuit damping diode, reverse polarity protection diode jumper

OUTPUT TECHNICAL DATA


Contact type 1 exchange AgSnO2
Nominal load (resistive) 12 A / 250 Vac
Max. cut-off capacity 12 A 8 relay module
Max. fuse current —

GENERAL TECHNICAL DATA


Operating temperature range –10...+50°C
Coil isolation / contacts 2.5 kVac / 60 s
Isolation between output terminal blocks 1 kVac / 60 s (between open contact poles)
Protection degree IP 00 IEC 529, EN60529
Surge category/degree of pollution III / 2
Reference Standards IEC 664-1, DIN VDE 0110.1
Power/status indicator Green LED / Yellow LED
Connection type 2.5 mm2 fixed screw terminal blocks and FLAT connector
Housing material UL94V-0 plastic
Approximate weight 192 g 345 g 688 g
Mounting information on rails, side by side
16 relay module
MOUNTING ACCESSORIES
Mounting rail compliant with IEC60715/TH35 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
Spare part relay (1) Cat. No. 8904001
Jumperred —
white —
blue —

98
Multi-relay modules
with fuse
• Control with both alternating and direct current
voltages
• Operation with both positive and negative
common 93 93 93
• LED status indicator
• Pluggable relay
• Output contact safety fuse
70 137 250

75 75 75

NOTES BLOCK DIAGRAM


Measurements include rail clamp clearance. POWER SUPPLY COMPATIBILITY
(1) Relay make and model are not final and A1 = + A2 = – negative common
may be replaced without notice. The technical
details shown are to be considered typical. (2) A1 = – A2 = + positive common
The interface is provided without a fuse and the A1 = ~ A2 = ~ AC power supply
fuse holder cap is in a bag inside the package.
The fuse must be of a suitable size for the load.
The max. value of 6.3 A refers to fuses compliant
with EN60127 and at the nominal approved
current of the fuse holder. Larger fuses can cause
damage to the fuse holder and to the module.

4 relay module
VERSIONS Cat. No. XR041U24F Cat. No. XR081U24F Cat. No. XR161U24F
4 relay module R41U24F
8 relay module R81U24F
16 relay module R161U24F
INPUT TECHNICAL DATA
Nominal voltage 24 Vac/dc ± 10%
Power consumption (1 channel) 22 mA ± 10%
Turn ON time 15 ms
Turn OFF time 10 ms
Protection circuit damping diode, reverse polarity protection diode jumper

OUTPUT TECHNICAL DATA


Contact type 1 exchange AgSnO2
Nominal load (resistive) 12 A / 250 Vac
Max. cut-off capacity 12 A 8 relay module
Max. fuse current 6.3 A (2)

GENERAL TECHNICAL DATA


Operating temperature range –10...+50°C
Coil isolation / contacts 2.5 kVac / 60 s
Isolation between output terminal blocks 1 kVac / 60 s (between open contact poles)
Protection degree IP 00 IEC 529, EN60529
Surge category/degree of pollution III / 2
Reference Standards IEC 664-1, DIN VDE 0110.1
Power/status indicator Green LED / Yellow LED
Connection type 2.5 mm2 fixed screw terminal blocks and FLAT connector
Housing material UL94V-0 plastic
Approximate weight 210 g 326 g 770 g
Mounting information on rails, side by side
16 relay module
MOUNTING ACCESSORIES
Mounting rail compliant with IEC60715/TH35 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
Spare part relay (1) Cat. No. 8904001
Jumperred —
white —
blue —

99
Multi-relay modules
• Control with direct current voltages
• Operation with negative common
• LED status indicator
• Pluggable relay 93 93 93

70 137 250

75 75 75

NOTES BLOCK DIAGRAM


Measurements include rail clamp clearance.
(1) Relay make and model are not final and may
be replaced without notice. The technical
details shown are to be considered typical.

VERSIONS Cat. No. XR042E24 Cat. No. XR082E24 Cat. No. XR162E24 4 relay module
4 relay module R42E24
8 relay module R82E24
16 relay module R162E24
INPUT TECHNICAL DATA
Nominal voltage 24 Vdc ± 10%
Power consumption (1 channel) 22 mA ± 10%
Turn ON time 15 ms
Turn OFF time 10 ms
Protection circuit damping diode, reverse polarity protection diode

OUTPUT TECHNICAL DATA


Contact type 2 exchanges AgNi
Nominal load (resistive) 8 A / 250 Vac
Max. cut-off capacity 8A
8 relay module
Max. fuse current —

GENERAL TECHNICAL DATA


Operating temperature range –10...+50°C
Coil isolation / contacts 2.5 kVac / 60 s
Isolation between output terminal blocks 1 kVac / 60 s (between open contact poles)
Protection degree IP 00 IEC 529, EN60529
Surge category/degree of pollution III / 2
Reference Standards IEC 664-1, DIN VDE 0110.1
Power/status indicator Green LED / Yellow LED
Connection type 2.5 mm2 fixed screw terminal blocks and FLAT connector
Housing material UL94V-0 plastic
Approximate weight 225 g 419 g 811 g
Mounting information on rails, side by side
16 relay module
MOUNTING ACCESSORIES
Mounting rail compliant with IEC60715/TH35 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
Spare part relay (1) Cat. No. 8904002
Jumperred —
white —
blue —

100
Multi-relay modules
• Control with both alternating and direct current
voltages
• Operation with both positive and negative
common
• LED status indicator 93 93 93
• Pluggable relay

70 137 250

75 75 75

NOTES BLOCK DIAGRAM


Measurements include rail clamp clearance. POWER SUPPLY COMPATIBILITY
(1) Relay make and model are not final and may A1 = + A2 = – negative common
be replaced without notice. The technical
details shown are to be considered typical. A1 = – A2 = + positive common
(2) Product made to order (not kept in stock). A1 = ~ A2 = ~ AC power supply

VERSIONS Cat. No. XR042EAD Cat. No. XR082EAD Cat. No. XR162EAD 4 relay module
4 relay module R42EAD
8 relay module R82EAD
16 relay module R162EAD
INPUT TECHNICAL DATA
Nominal voltage 24 Vac/dc ± 10%
Power consumption (1 channel) 22 mA ± 10%
Turn ON time 15 ms
Turn OFF time 5 ms
Protection circuit damping diode, reverse polarity protection diode jumper

OUTPUT TECHNICAL DATA


Contact type 2 exchanges AgNi
Nominal load (resistive) 8 A / 250 Vac
Max. cut-off capacity 8A
8 relay module
Max. fuse current —

GENERAL TECHNICAL DATA


Operating temperature range –10...+50°C
Coil isolation / contacts 2.5 kVac / 60 s
Isolation between output terminal blocks 1 kVac / 60 s (between open contact poles)
Protection degree IP 00 IEC 529, EN60529
Surge category/degree of pollution III / 2
Reference Standards IEC 664-1, DIN VDE 0110.1
Power/status indicator Green LED / Yellow LED
Connection type 2.5 mm2 fixed screw terminal blocks and FLAT connector
Housing material UL94V-0 plastic
Approximate weight 227 g 427 g 835 g
Mounting information on rails, side by side
16 relay module
MOUNTING ACCESSORIES
Mounting rail compliant with IEC60715/TH35 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
Spare part relay (1) Cat. No. 8904002
Jumperred —
white —
blue —

101
Multi-relay modules
with test buttom
• Control with both alternating and direct current
voltages
• Operation with both positive and negative
common 93
• LED status indicator
• Pluggable relay
• Test with buttons and switches 136

75

NOTES BLOCK DIAGRAM


Measurements include rail clamp clearance. POWER SUPPLY COMPATIBILITY
(1) Relay make and model are not final and may A1 = + A2 = – negative common
be replaced without notice. The technical
details shown are to be considered typical. A1 = – A2 = + positive common
(2) Replaces cards XRP08124 and XRD08124. A1 = ~ A2 = ~ AC power supply

VERSIONS Cat. No. XRMP081CM (2)


P = test button
With push-button and DIP-switch RMPO81CM
D = DIP-switch
IG = general switch for isolating buttons and the DIP-switch

INPUT TECHNICAL DATA


Nominal voltage 24 Vac/dc ± 10%
Power consumption (1 channel) 22 mA ± 10%
Turn ON time 15 ms
Turn OFF time 5 ms
Protection circuit damping diode, reverse polarity protection diode jumper

OUTPUT TECHNICAL DATA


Contact type 1 exchange AgSnO2 for 8 relays
Nominal load (resistive) 12 A / 250 Vac
Max. cut-off capacity 12 A
Max. fuse current —

GENERAL TECHNICAL DATA


Operating temperature range –10...+50°C This product can be operated in either alternating or direct current.
Coil isolation / contacts 2.5 kVac / 60 s Relay activation can be forced temporarily using the relevant button, or perma-
Isolation between output terminal blocks 1 kVac / 60 s (between open contact poles) nently using a DIP-switch.
Protection degree IP 00 IEC 529, EN60529
Surge category/degree of pollution III / 2
Reference Standards IEC 664-1, DIN VDE 0110.1
Power/status indicator Green LED / Yellow LED
Connection type 2.5 mm² fixed screw terminal blocks
Housing material UL94V-0 plastic
Approximate weight 350 g
Mounting information on rails, side by side IG P D (not shown)

MOUNTING ACCESSORIES
Mounting rail compliant with IEC60715/TH35 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
Spare part relay (1) Cat. No. 8904001
Jumperred —
white —
blue —

102
Super compact
relay modules
CR & CRE series
• 3 kV Input/Output isolation 108 108
• 1 kV isolation between output contacts
• Fast cabling extractable terminal blocks
• Control with both alternating and direct current
voltages
119 119
• Operation with both positive and negative A A
common
A = 22.5 mm CR version, 35 mm CRE version A = 22.5 mm CR version, 35 mm CRE version

NOTES BLOCK DIAGRAM BLOCK DIAGRAM


Measurements include rail clamp clearance.
(1) Relay make and model are not final and may
be replaced without notice. The technical
details shown are to be considered typical.
CR4-1 and CRE4-1: 4-relay module with exchange
contact, inputs and outputs with removable terminal
blocks.
CR8-1 and CR8E-1: 8-relay module with NA con-
tact, inputs and outputs with removable terminal
blocks.

VERSIONS Cat. No. XCRE41 Cat. No. XCR4 Cat. No. XCRE81 Cat. No. XCR81
Pluggable relay CRE4-1 CRE8-1
Fixed relay CR4-1 CR8-1

INPUT TECHNICAL DATA


Nominal voltage 24 Vac/dc ± 10% 24 Vac/dc ± 10%
Power consumption (1 channel) 16 mA ± 10% 16 mA ± 10%
Turn ON time 7 ms 7 ms
Turn OFF time 3 ms 3 ms
Protection circuit damping diode, reverse polarity protection diode jumper damping diode, reverse polarity protection diode jumper

OUTPUT TECHNICAL DATA


Contact type 1 AgNiO exchange for 4 relays 1 NA contact for 8 relays
Nominal load (resistive) 8 A / 250 Vac 8 A / 250 Vac
Max. cut-off capacity 2000 VA 2000 VA
Max. fuse current — —

GENERAL TECHNICAL DATA


Operating temperature range –10...+50°C –10...+50°C
Coil isolation / contacts 2.5 kVac / 60 s 3 kVac / 60 s
Isolation between output terminal blocks 1 kVac / 60 s (between open contact poles) 1 kVac / 60 s (between open contact poles)
Protection degree IP 20 IEC 529, EN60529 IP 20 IEC 529, EN60529
Surge category/degree of pollution III / 2 III / 2
Reference Standards IEC 664-1, DIN VDE 0110.1 IEC 664-1, DIN VDE 0110.1
Power/status indicator Green LED / Yellow LED Green LED / Yellow LED
Connection type 2.5 mm² fixed screw terminal blocks 2.5 mm² removable screw terminal blocks
Housing material UL94V-0 plastic UL94V-0 plastic
Approximate weight 143 g (180 g removable version) 199 g (250 g removable version)
Mounting information on rails, side by side on rails, side by side

MOUNTING ACCESSORIES
Mounting rail compliant with IEC60715/TH35 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 PR/DIN/AC - PR/DIN/AS - PR/DIN/AL PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
Spare part relay (1) Cat. No. 8904042 Cat. No. 8904042
Jumperred — —
white — —
blue — —

103
Super compact
relay modules
CR & CRE series
• 3 kV Input/Output isolation 108
• 1 kV isolation between output contacts
• Fast cabling extractable terminal blocks
• Control with both alternating and direct current
voltages
119
• Operation with both positive and negative A
common
A = 22.5 mm CR version, 35 mm CRE version

NOTES BLOCK DIAGRAM


Measurements include rail clamp clearance.
(1) Relay make and model are not final and may
be replaced without notice. The technical
details shown are to be considered typical.
(2) Version made to order (not kept in stock);
contact our sales office for availability.

VERSIONS Cat. No. XCRE42SC Cat. No. XCR42SC


Pluggable relay CRE4-2SC (2)
Fixed relay CR4-2SC (2)

INPUT TECHNICAL DATA


Nominal voltage 24 Vac/dc ± 10%
Power consumption (1 channel) 25 mA ± 10%
Turn ON time 7 ms
Turn OFF time 2 ms
Protection circuit damping diode, reverse polarity protection diode jumper

OUTPUT TECHNICAL DATA


Contact type 2 AgNi exchanges for 4 relays
Nominal load (resistive) 8 A / 250 Vac
Max. cut-off capacity 2000 VA
Max. fuse current —

GENERAL TECHNICAL DATA


Operating temperature range –10...+50°C
Coil isolation / contacts 2.5 kVac / 60 s
Isolation between output terminal blocks 1 kVac / 60 s (between open contact poles)
Protection degree IP 20 IEC 529, EN60529
Surge category/degree of pollution III / 2
Reference Standards IEC 664-1, DIN VDE 0110.1
Power/status indicator Green LED / Yellow LED
Connection type 2.5 mm² removable screw terminal blocks
Housing material UL94V-0 plastic
Approximate weight 137 g (180 g removable version)
Mounting information on rails, side by side

MOUNTING ACCESSORIES
Mounting rail compliant with IEC60715/TH35 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
Spare part relay (1) Cat. No. 8904052
Jumperred —
white —
blue —

104
Siemens S7 PLC
(300 and 400)
interface modules
• Super compact size with CR version 108
• Fast cabling
• Pluggable relay

119
A

A = 22.5 mm CR version, 35 mm CRE version

NOTES BLOCK DIAGRAM


(1) Relay make and model are not final and may be
replaced without notice. The technical details shown
are to be considered typical.
(2) Product made to order (not kept in stock).

VERSIONS Cat. No. XCRE83 Cat. No. XCR83


Pluggable relay CRE8-3
Fixed relay CR8-3

INPUT TECHNICAL DATA


Nominal voltage 24 Vac/dc ± 10%
Power consumption (1 channel) 16 mA ± 10%
Turn ON time 15 ms
Turn OFF time 5 ms
Protection circuit damping diode, reverse polarity protection diode jumper

OUTPUT TECHNICAL DATA


Contact type 1 NA contact for 8 relays
Nominal load (resistive) 10 A / 250 Vac
Max. cut-off capacity 2000 VA
Max. fuse current —

GENERAL TECHNICAL DATA


Operating temperature range –10...+50°C
Coil isolation / contacts 3 kVac / 60 s
Isolation between output terminal blocks 1 kVac / 60 s (between open contact poles)
Protection degree IP 20 IEC 529, EN60529
Surge category/degree of pollution III / 2
Reference Standards IEC 664-1, DIN VDE 0110.1
Power/status indicator Green LED / Yellow LED
Connection type male 16 pole flat
Housing material UL94V-0 plastic
Approximate weight 199 g
Mounting information on rails, side by side

MOUNTING ACCESSORIES
Mounting rail compliant with IEC60715/TH35 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 —
Spare part relay (1) Cat. No. 8904042
Jumperred —
white —
blue —

105
These tables are used for quickly identifying items and verifying whether all of the product’s technical details satisfy the set requirements.

Input modules
Number of Applicable load
Input voltage Notes Type Cat. No. Page
channels Voltage Current
1 5...24 Vdc 5…48 Vdc 3A (2) O332060 XO332060 107
1 5…24 Vdc 5…48 Vdc 500 mA (2) CWOT 6-2082 X766082 113
1 12…24 Vdc 5…48 Vdc 500 mA (2) CWOT 6-2083 X766083 112
1 12…24 Vdc 5…48 Vdc 5A (1) CM1S024E XCM1S024E 108
1 24 Vdc 5…48 Vdc 2A (1) CM1S024 XCM1S024 108
1 5…12 Vdc 5…24 Vdc 5A (2) (4) CKS15NA XCKS15NA 110
1 5…24 Vdc 5…24 Vdc 30 mA (2) CKS1S XCKS1S 113
1 24 Vdc 5…24 Vdc 5A (2) (4) CKS15NB XCKS15NB 110
1 5...24 Vdc 5...24 Vdc 5A (2) (5) CKS15E XCKS15E 111
1 12…24 Vdc 12...240 Vac 3A (1) CM1T024E XCM1T024E 109
1 5...24 Vdc 24...240 Vac 4A (2) O332240 XO332240 107
1 24 Vdc 48...240 Vac 2A (1) CM1T024 XCM1T024 109
2 12…24 Vdc 12…24 Vdc 2 x 2.5 A (2) CKS22 XCKS22 109
4 24 Vdc 5…48 Vdc 2A (1) (3) (4) R41S24F XR041S24F 116
4 24 Vdc 5…48 Vdc 2A (1) (3) R42S24 XR042S24 114
4 24 Vdc 48...240 Vac 2A (1) (3) R42T24 XR042T24 115
8 24 Vdc 5…48 Vdc 2A (1) (3) (4) R81S24F XR081S24F 116
8 24 Vdc 5…48 Vdc 2A (1) (3) R82S24 XR082S24 114
8 24 Vdc 48...240 Vac 2A (1) (3) R82T24 XR082T24 115
8 5...24 Vdc 12...24 Vdc 8 x 2.5 A (2) (5) COP082 XCOP082 117
16 24 Vdc 5…48 Vdc 2A (1) (3) (4) R161S24F XR161S24F 116
16 24 Vdc 5…48 Vdc 2A (1) (3) R162S24 XR162S24 114
16 24 Vdc 48...240 Vac 2A (1) (3) R162T24 XR162T24 115

Notes (4) safety fuse on output


(1) pluggable relay version (5) electronic protection on output
(2) fixed relay version
(3) universal common, negative DC control, positive DC

on rail, space 4 mm from adjacent components

106
Single solid state relay
• Fixed relay
• Reduced overall dimensions

77 77

12 12
54 54

NOTES BLOCK DIAGRAM BLOCK DIAGRAM


(1) Relay make and model are not final and may be
replaced without notice. The technical details shown
are to be considered typical.

VERSIONS Cat. No. XO332060 Cat. No. XO332240


Pluggable relay — —
Fixed relay O332060 O332240

INPUT TECHNICAL DATA


Input voltage 4…30 Vdc 4…30 Vdc
Signal 1 input level > 3 Vdc > 3 Vdc
Signal 0 input level < 1 Vdc < 1 Vdc
Power consumption < 35 mA < 35 mA
Commutation frequency 100 Hz max 100 Hz max
Connection type 2.5 mm² fixed screw terminal blocks 2.5 mm² fixed screw terminal blocks

OUTPUT TECHNICAL DATA


Output voltage 5…60 Vdc 24…240 Vac (zero crossing)
Permanent load current 3 A at 20°C (see graph) 4 A at 20°C (see graph)
Max current 4 A to 20°C (5 A / 5 s - 25 A / 10 ms) 5 A to 20°C (6 A / 5 s - 25 A / 10 ms)
Leakage current with signal 0 1 mA 5 mA
OFF/ON switching time — 10 ms max
Protection circuit diode RC filters
Connection type 2.5 mm² fixed screw terminal blocks 2.5 mm² fixed screw terminal blocks
GENERAL TECHNICAL DATA
Operating temperature range -20…+60°C (see graph) -20…+60°C (see graph)
Coil isolation/contacts 4 kVac / 60 s 4 kVac / 60 s
Protection degree IP 00 IEC529, EN60529 IP 00 IEC529, EN60529
Reference Standards IEC 664-1, DIN VDE 0110.1 IEC 664-1, DIN VDE 0110.1
Degree of pollution 2 2
Surge category III III
Power/status indicator LED LED
Housing material UL94V-0 polyamide UL94V-0 polyamide
Approximate weight 36 g 36 g
Mounting information on rail, space 4 mm from adjacent components on rail, space 4 mm from adjacent components

MOUNTING ACCESSORIES
Mounting rail compliant with IEC60715/TH35 PR/3/AC, PR/3/AS PR/3/AC, PR/3/AS
Mounting rail type according to IEC60715/G32 PR/DIN/AC - PR/DIN/AS - PR/DIN/AL PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
Spare part relay (1) — —
Jumperred — —
white — —
blue — —

4 4
3 3
(DC)
Iout (DC)

Iout (DC)
(AC)

2 2
Iout

Iout

1 1

20 30 40 50 60 70 80 90 100 20 30 40 50 60 70 80 90 100
Ambient Temperature (°C) Ambient Temperature (°C)

107
Single solid state relay
CM series
• Low cost
• For switching loads in DC (version S)
• Pluggable relay
75 75

16 16
68 68

NOTES BLOCK DIAGRAM BLOCK DIAGRAM


(1) Relay make and model are not final and may
be replaced without notice. The technical details
shown are to be considered typical
(2) Version made to order (not kept in stock); contact
our sales office for availability.

This series can be mounted side-by-side without the


need for spacing to allow the relay to cool.

VERSIONS Cat. No. XCM1S024 Cat. No. XCM1S024E


Pluggable relay CM1S024 (2) CM1S024E (2)
Fixed relay — —

INPUT TECHNICAL DATA


Input voltage 24 Vdc (19.2…28.8 Vdc) 12-24 Vdc (10…32 Vdc)
Signal 1 input level > 19.2 Vdc > 10 Vdc
Signal 0 input level < 1 Vdc < 10 Vdc
Power consumption (1 channel) < 20 mA < 16 mA
Commutation frequency 100 Hz max 100 Hz max
Connection type 2.5 mm² fixed screw terminal blocks 2.5 mm² fixed screw terminal blocks

OUTPUT TECHNICAL DATA


Output voltage 3…50 Vdc 0…35 Vdc
Permanent load current 2 A to 40°C 5 A at 60°C
Max current 8 A /10 ms 120 A (peak)
Leakage current with signal 0 0.1 mA 10 µA
OFF/ON switching time 100 µs / 1 ms 50 μs / 250 μs
Protection circuit diode diode
Connection type 2.5 mm² fixed screw terminal blocks 2.5 mm² fixed screw terminal blocks
GENERAL TECHNICAL DATA
Operating temperature range -20...+80°C over 40°C apply a derating of 0.04A/°C -20...+80°C over 60°C apply a derating of 0.05A/°C
Coil isolation/contacts 2.5 kVac / 60 s 2.5 kVac / 60 s
Protection degree IP 00 IEC529, EN60529 IP 00 IEC529, EN60529
Reference Standards IEC 664-1, DIN VDE 0110.1 IEC 664-1, DIN VDE 0110.1
Degree of pollution 3 3
Surge category III III
Power/status indicator LED LED
Housing material UL94V-0 polyamide UL94V-0 polyamide
Approximate weight — —
Mounting information vertical on rails, side by side vertical on rails, side by side

MOUNTING ACCESSORIES
Mounting rail compliant with IEC60715/TH35 PR/3/AC, PR/3/AS PR/3/AC, PR/3/AS
Mounting rail type according to IEC60715/G32 — —
Spare part relay (1) Cat. No. 8904404 Cat. No. 8904402
Jumperblack Cat. No. XCMB16B Cat. No. XCMB16B
white — —
blue — —

Jumper

108
Single solid state relay
CM series
• Low cost
• For switching loads in DC (version S)
• Pluggable relay
75 75

16 16
68 68

NOTES BLOCK DIAGRAM BLOCK DIAGRAM


(1)Relay make and model are not final and may be
replaced without notice. The technical details
shown are to be considered typical
(2) Version made to order (not kept in stock); contact
our sales office for availability.

This series can be mounted side-by-side without the


need for spacing to allow the relay to cool.

VERSIONS Cat. No. XCM1T024 Cat. No. XCM1T024E


Pluggable relay CM1T024 (2) CM1T024E (2)
Fixed relay — —

INPUT TECHNICAL DATA


Input voltage 24 Vdc (19.2…28.8 Vdc) 12-24 Vdc (10…32 Vdc)
Signal 1 input level > 19.2 Vdc > 10 Vdc
Signal 0 input level < 1 Vdc < 10 Vdc
Power consumption (1 channel) < 20 mA < 16 mA
Commutation frequency 100 Hz max 100 Hz max
Connection type 2.5 mm² fixed screw terminal blocks 2.5 mm² fixed screw terminal blocks

OUTPUT TECHNICAL DATA


Output voltage 48…280 Vac (zero crossing) 12…275 Vac (zero crossing)
Permanent load current 3 A to 40°C 3 A at 60°C
Max current 120 A /10 ms 120 A (peak)
Leakage current with signal 0 5 mA 1 mA
OFF/ON switching time 1/2 cycle + 1 ms 50 μs / 250 μs
Protection circuit — —
Connection type 2.5 mm² fixed screw terminal blocks 2.5 mm² fixed screw terminal blocks
GENERAL TECHNICAL DATA
Operating temperature range -20...+80°C over 40°C apply a derating of 0.05A/°C -20...+80°C over 40°C apply a derating of 0.025A/°C
Coil isolation/contacts 2.5 kVac / 60 s 2.5 kVac / 60 s
Protection degree IP 00 IEC529, EN60529 IP 00 IEC529, EN60529
Reference Standards IEC 664-1, DIN VDE 0110.1 IEC 664-1, DIN VDE 0110.1
Degree of pollution 3 3
Surge category III III
Power/status indicator LED LED
Housing material UL94V-0 polyamide UL94V-0 polyamide
Approximate weight — —
Mounting information vertical on rails, side by side vertical on rails, side by side

MOUNTING ACCESSORIES
Mounting rail compliant with IEC60715/TH35 PR/3/AC, PR/3/AS PR/3/AC, PR/3/AS
Mounting rail type according to IEC60715/G32 — —
Spare part relay (1) Cat. No. 8904405 Cat. No. 8904403
Jumperblack Cat. No. XCMB16B Cat. No. XCMB16B
white — —
blue — —

Jumper

109
Solid State Relay
with output protection
• Protection against short circuit, overload,overtemperature
91
• Input and output status LED
• Output extravoltage suppressor diode
• Extralow current absorbing
• Compact dimension
100
6

NOTES BLOCK DIAGRAM BLOCK DIAGRAM BLOCK DIAGRAM


(1) La corrente massima dipende dal numero di
uscite che sono contemporaneamente attive e dalla IN POW
+
IN POW
+
IN POW
+
temperatura ambiente. A1+ POW A1+ POW A1+ POW
13+ 13+ 13+
(2) The protection cuts off the output current, the FUSE
IS OUT IS OUT IS OUT
yellow LED turns off or reduces its light, the output 3A LOAD LOAD LOAD
turns on automatically when the overload is re- 14 14 14
IN IN IN
moved. The current limiting depending also by the

LOAD

LOAD
LOAD
A2– A2– A2–
operating temperature, for more accuracy or to pro-
OUT OUT OUT
tect cables with small section or rated current lower – – –
than the maximum current, an external fuse must be GND FAIL GND FAIL GND
provided.

ORDER CODE XCKS024DC024DC03 XCKS024DC024DC05 XCKS024DC024DC10


Model CKS-024DC/024DC/03 CKS-024DC/024DC/05 CKS-024DC/024DC/10
INPUT TECHNICAL DATA
Input voltage 5...24 Vdc (4.7…32 Vdc) 5...24 Vdc (4.7…32 Vdc) 5...24 Vdc (4.7…32 Vdc)
Level 1 (high) input signal > 4.5 Vdc > 4.5 Vdc > 4.5 Vdc
Level 0 (low) input signal < 4.2 Vdc < 4.2 Vdc < 4.2 Vdc
Rated current ≤ 10 mA at 24 Vdc ≤ 10 mA at 24 Vdc ≤ 10 mA at 24 Vdc
Input channels 1 1 1
OUTPUT TECHNICAL DATA
Output voltage 5...24 Vdc (5…32 Vdc) 5...24 Vdc (5…32 Vdc) 5...24 Vdc (5…32 Vdc)
Continuous current 3 A / 24 Vdc at 45°C (1) 8 A / 24 Vdc at 45°C (1) 10 A / 24 Vdc at 45°C (1)
5 A / 24 Vdc at 20°C (1) 5 A / 24 Vdc at 55°C (1) 15 A / 24 Vdc at 20°C (1)
Maximun current 5 A / 2 s +/- 10% at 25°C (1) 21 A / 100 ms at 25°C (1) 21 A / 100 ms at 25°C (1)
Min. applicable load 5 V / 10 mA 5 V / 10 mA 5 V / 10 mA
Leakage current 0 signal < 25 μA at 24 Vdc < 25 μA at 24 Vdc < 25 μA at 24 Vdc
Isolation between open contacts — — —
Internal protection auto resettable fuse / suppressor diode electronic against short circuit, oveload, overtemperature (2) / suppressor diode
External protection fuse 3 A max. fuse 5 A max. fuse 10 A max.
GENERAL TECHNICAL DATA
Operating temperature -20…+60°C -20...+60°C with thermal protection (2) -20...+60°C with thermal protection (2)
I/O isolation 3 kVac / 60 s 3 kVac / 60 s 3 kVac / 60 s
Max. switching frequency 200 Hz max. 200 Hz max. 200 Hz max.
Status display LED green IN / LED yellow OUT LED green IN / LED yellow OUT / Fail LED green IN / LED yellow OUT / Fail
Protection degree IP20 IEC529 EN60529 (with end plate on the last module)
Reference Standard — — —
Pollution degree 2 2 2
Overvoltage category II II II
Connection terminals 2.5 mm² (AWG26-14) fixed spring type 2.5 mm² (AWG26-14) fixed spring type 2.5 mm² (AWG26-14) fixed spring type
Housing material Polyamide UL94V-0 Polyamide UL94V-0 Polyamide UL94V-0
Approx. weight 30 g (1.06 oz) 30 g (1.06 oz) 30 g (1.06 oz)
Mounting information Vertical on rail adjacent without gap Vertical on rail adjacent without gap Vertical on rail adjacent without gap
MOUNTING ACCESSORIES
Mounting rail type IEC60715/TH35-7,5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/ PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/ PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/
AS/ZB AS/ZB AS/ZB
Mounting rail type IEC60715/G32 — — —
Replacement relay — — —
Plug-in jumper 2 poles PTC/4/02 Cod. PTC0402 PTC/4/02 Cod. PTC0402 PTC/4/02 Cod. PTC0402
3 poles PTC/4/03 Cod. PTC0403 PTC/4/03 Cod. PTC0403 PTC/4/03 Cod. PTC0403
5 poles PTC/4/05 Cod. PTC0405 PTC/4/05 Cod. PTC0405 PTC/4/05 Cod. PTC0405
10 poles PTC/4/10 Cod. PTC0410 PTC/4/10 Cod. PTC0410 PTC/4/10 Cod. PTC0410
42 poles PTC/4/00 Cod.PTC0400 PTC/4/00 Cod.PTC0400 PTC/4/00 Cod.PTC0400
Marking tags CNU/8/51 Cat. No. NU0851 CNU/8/51 Cat. No. NU0851 CNU/8/51 Cat. No. NU0851
End plate CK/PT Cat. No. XCKPT CK/PT Cat. No. XCKPT CK/PT Cat. No. XCKPT

110
Solid State Relaya
with output for
AC loads
• Output extravoltage varistor 91
• Extralow current absorbing
• Compact dimension

100
6

NOTES BLOCK DIAGRAM


(1) Maximum output current of each channel depen-
ds on surrounding air temperature, on the number L
of output contemporarily active and on the current A1+ L FUSE
5A
flowing through them.
N
(2) An external fuse must be provided to prevent
damage to the circuit and to the cables. The non- ZC
N

resettable internal fuse (calibrated track) has the only

LOAD
A2–
purpose to avoid damages in the even of failure of IN
the external protection.
LOAD

ORDER CODE XCKS024DC230AC05


Model CKS-024DC/230AC/05
INPUT TECHNICAL DATA
Input voltage 12...24 Vdc (9…30 Vdc / 9...30Vac )
Level 1 (high) input signal > 8.5 Vdc
Level 0 (low) input signal < 8 Vdc
Rated current ≤ 10 mA at 24 Vdc
Input channels 1
OUTPUT TECHNICAL DATA
Output voltage 230 Vac (20…265 Vac)
Continuous current 5 A / 230 Vac at 45°C (1)

Maximun current 6A
Min. applicable load 24 Vac / 10 mA
Leakage current 0 signal < 25 μA at 24 Vdc
Isolation between open contacts —
Internal protection not replaceable fuse 10 A / varistor (2)
External protection fuse 5 A max.
GENERAL TECHNICAL DATA
Operating temperature -20 ... +45°C
I/O isolation 3 kVac / 60 s
Max. switching frequency —
Status display LED green IN
Protection degree IP20 IEC529 EN60529 (with end plate on the last module)
Reference Standard —
Pollution degree 2
Overvoltage category II
Connection terminals 2.5 mm² (AWG26-14) fixed spring type
Housing material Polyamide UL94V-0
Approx. weight 30 g (1.06 oz)
Mounting information vertical on rail adjacent without gap
MOUNTING ACCESSORIES
Mounting rail type IEC60715/TH35-7,5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB

Mounting rail type IEC60715/G32 —


Replacement relay —
Plug-in jumper 2 poles PTC/4/02 Cod. PTC0402
3 poles PTC/4/03 Cod. PTC0403
5 poles PTC/4/00 Cod.PTC0400
10 poles PTC/4/10 Cod. PTC0410
42 poles PTC/4/00 Cod.PTC0400
Marking tags CNU/8/51 Cat. No. NU0851
End plate CK/PT Cat. No. XCKPT

111
Solid state single relay
with SPDT output
• 10…40 Vdc operating voltage
• Output with exchange contact simulation
79
• 5...48 Vdc 500 mA output voltage
• Commutation frequency up to 1 KHz
• 3.75 kV Input/Output isolation

84
6.2

NOTES BLOCK DIAGRAM


Opto-isolators offer many advantages over elec-
tromechanical relays, such as increased electrical
duration, super-high commutation frequency, insen-
sitivity to vibrations, broad operating range and low
power consumption.
Unfortunately, solid state relays are only able to
switch a signal by simulating the NA contact of a
relay, whereas this product, thanks to its integrated
technology, offers all the benefits of solid state relays
and eliminates the need for an NC contact.
14 12 +11

VERSIONS Cat. No. X766083


Pluggable relay —
Fixed relay CWOT 6-2083

INPUT TECHNICAL DATA


Input signal 24 Vdc (range 10…40 Vdc)
Signal 1 input level (ON) >5 Vdc
Signal 0 input level (OFF) <5 Vdc
Power consumption 6 mA
Protection device suppression diode

OUTPUT TECHNICAL DATA


Output signal 5…48 Vdc
Load current 10…500 mA
Switching delay 12 µs ON / 12 µs OFF
Protection device suppression diode
Output type NPN/PNP transistor with exchange contact simulation

GENERAL TECHNICAL DATA


Operating temperature range -25 …+60°C
Input/output isolation 3.75 kVac / 60 s
Max commutation frequency <1 KHz
Protection degree IP 20 IEC529 EN60529
Reference Standards IEC 664-1, DIN VDE
Degree of pollution 2
Surge category III
Connection type 2.5 mm² fixed screw terminal blocks
Case material PPE
Approximate weight 29 g
Mounting information vertical on rails, side by side

MOUNTING ACCESSORIES
Mounting rail compliant with IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 —
Spare part relay (1) —
Jumper— —
Marking tag neutral —
marked —
marked —
End section —

112
Signal optoisolators
• Suitable for the isolation and transmission of high-frequency
digital signals
• Status LED 91 79
• 5, 12 and 24 Vdc operating voltages
• Input/Output isolation

100
84
6 6.2

NOTES BLOCK DIAGRAM BLOCK DIAGRAM


(1) Product made to order (not kept in stock).
Used in high-frequency digital signal transmission circuits
such as counters, encoders, etc., it eliminates the influence
of different reference potentials (mass or ground) on the
signal and attenuates the influence of EMI interference,
particularly with low-level signals (e.g. 5 Vdc), as well as
allowing for secure and clean transmission to greater
distances; the use of balanced shielded conductors (two
signal conductors plus shield) is however recommended;
for frequencies above 25 Hz, the input status LED will be
constantly lit, indicating that a transmission is in process.

VERSIONS Cat. No. XCKS1S Cat. No. X766082


CKS1S (1) CWOT 6-6082

INPUT TECHNICAL DATA


Input signal 3…30 Vdc 4.5…28 Vdc
Signal 1 input level (ON) ≥ 3 Vdc >4.2 Vdc
Signal 0 input level (OFF) ≤ 3 Vdc <2.7 Vdc
Power consumption ≤ 10 mA at 24 Vdc 0.1 mA

OUTPUT TECHNICAL DATA


Output signal 3…30 Vdc 5…48 Vdc
Permanent load current 80 mA / 30 Vdc at 25°C 10…500 mA
Min. applicable load 10 mV / 2 mA —
Switching delay — 12 µs ON / 12 µs OFF

GENERAL TECHNICAL DATA


Operating temperature range -20…+60°C -25…+60°C
Input/output isolation 3 kVac / 60 s 3.75 kVac / 60 s
Max commutation frequency 20 kHz max duty cycle 50/50, 70/30 max <20 KHz
Protection degree IP 20 IEC529 EN60529 IP 20 IEC529 EN60529
Reference Standards IEC 664-1, EN50081-1 IEC 664-1, DIN VDE
Degree of pollution 2 2
Surge category II III
Connection type 2.5 mm2, AWG26-14 spring type 2.5 mm2, AWG26-14 screw type
Housing material UL94V-0 polyamide PPE
Approximate weight 32 g 29 g
Mounting information vertical on rails, side by side vertical on rails, side by side

MOUNTING ACCESSORIES
Mounting rail compliant with IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 — —
Spare part relay (1) — —
Jumper— Cat. No. PTCCK42 (42 poles) —
Marking tag neutral Cat. No. NU0851 —
marked — —
marked — —
End section Cat. No. XCKPT —

113
Multi-solid
state relay
modules
• For switching loads in DC 93 93 93
• Pluggable relay

70 137 250

75 75 75

NOTES BLOCK DIAGRAM


(1) Relay make and model are not final and may be POWER SUPPLY COMPATIBILITY
replaced without notice. The technical details shown A1 = + A2 = – negative common
are to be considered typical.
(2) Version made to order (not kept in stock); contact A1 = – A2 = + positive common
our sales office for availability.

VERSIONS Cat. No. XR042S24 Cat. No. XR082S24 Cat. No. XR162S24
4 relay module R42S24 (2) 4 relay module
8 relay module R82S24 (2)
16 relay module R162S24 (2)
INPUT TECHNICAL DATA
Input voltage 24 Vdc (19.2…28.8 Vdc)
Signal 1 input level > 19.2 Vdc
Signal 0 input level < 1 Vdc
Power consumption (1 channel) < 20 mA
Commutation frequency 100 Hz max

OUTPUT TECHNICAL DATA


Output voltage 3…50 Vdc
Permanent load current 2 A to 40°C
Max current 8 A /10 ms
Leakage current with signal 0 0.1 mA 8 relay module
OFF/ON switching time 100 μs / 1 ms
Protection circuit diode
Max. fuse current —
GENERAL TECHNICAL DATA
Operating temperature range -20...+80°C over 40°C apply a derating of 0.04A/°C
Input/Output isolation 2.5 kVac / 60 s
Isolation between output terminal blocks 1 kVac / 60 s (between open contact poles)
Protection degree IP 00 IEC 529, EN60529
Surge category/degree of pollution III / 2
Reference Standards IEC 664-1, DIN VDE 0110.1
Power/status indicator Green LED / Yellow LED
Connection type 2.5 mm2 fixed screw terminal blocks and FLAT connector
Housing material UL94V-0 plastic
Approximate weight 207 g 379 g 756 g
Mounting information on rails, side by side

MOUNTING ACCESSORIES 16 relay module


Mounting rail compliant with IEC60715/TH35 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
Spare part relay (1) Cat. No. 8904404
Jumper —

114
Multi-solid
state relay
modules
• For switching loads in DC 93 93 93
• Pluggable relay

70 137 250

75 75
75

NOTES BLOCK DIAGRAM


(1) Relay make and model are not final and may be POWER SUPPLY COMPATIBILITY
replaced without notice. The technical details shown A1 = + A2 = – negative common
are to be considered typical.
(2) Version made to order (not kept in stock); contact A1 = – A2 = + positive common
our sales office for availability.

VERSIONS Cat. No. XR042T24 Cat. No. XR082T24 Cat. No. XR162T24 4 relay module
4 relay module R42T24 (2)
8 relay module R82T24 (2)
16 relay module R162T24 (2)
INPUT TECHNICAL DATA
Input voltage 24 Vdc (19.2…28.8 Vdc)
Signal 1 input level > 19.2 Vdc
Signal 0 input level < 1 Vdc
Power consumption (1 channel) < 20 mA
Commutation frequency 100 Hz max

OUTPUT TECHNICAL DATA


Output voltage 48…240 Vac (zero crossing)
Permanent load current 3 A to 40°C
Max current 120 A /10 ms
Leakage current with signal 0 5 mA 8 relay module
OFF/ON switching time 1/2 cycle + 1 ms
Protection circuit —
Max. fuse current —
GENERAL TECHNICAL DATA
Operating temperature range -20...+80°C over 40°C apply a derating of 0.05A/°C
Coil isolation/contacts 2.5 kVac / 60 s
Protection degree 1 kVac / 60 s (between open contact poles)
Reference Standards IP 00 IEC 529, EN60529
Degree of pollution III / 2
Surge category IEC 664-1, DIN VDE 0110.1
Relay model (1) Green LED / Yellow LED
Power/status indicator 2.5 mm2 fixed screw terminal blocks and FLAT connector
Housing material UL94V-0 plastic
Approximate weight (4/8/16 relay) 207 g 379 g 756 g
Mounting information on rails, side by side

16 relay module
MOUNTING ACCESSORIES
Mounting rail compliant with IEC60715/TH35 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
Spare part relay (1) Cat. No. 8904405
Jumper —

115
Multi-solid state relay
modules with fuse
• For switching loads in DC
• Safety fuse on output
• Pluggable relay 93 93 93

67 137 250

75 75 75

NOTES BLOCK DIAGRAM


(1) Relay make and model are not final and may be POWER SUPPLY COMPATIBILITY
replaced without notice. The technical details shown A1 = + A2 = – negative common
are to be considered typical.
(2) The fuse must be of a suitable size for the load. A1 = – A2 = + positive common
The max. value of 6.3 A refers to fuses compliant
with EN60127 and at the nominal approved current
of the fuse holder.
Larger fuses can cause damage to the fuse holder
and to the module.
(3) Version made to order (not kept in stock); contact
our sales office for availability.

VERSIONS Cat. No. XR041S24F Cat. No. XR081S24F Cat. No. XR161S24F 4 relay module
4 relay module R41S24F (3)
8 relay module R81S24F (3)
16 relay module R161S24F (3)
INPUT TECHNICAL DATA
Input voltage 24 Vdc (19.2…28.8 Vdc)
Signal 1 input level > 19.2 Vdc
Signal 0 input level < 1 Vdc
Power consumption (1 channel) < 20 mA
Commutation frequency 100 Hz max

OUTPUT TECHNICAL DATA


Output voltage 3…50 Vdc
Permanent load current 2 A to 40°C
Max current 8 A /10 ms 8 relay module
Leakage current with signal 0 0.1 mA
OFF/ON switching time 100 μs / 1 ms
Protection circuit diode
Max. fuse current —
GENERAL TECHNICAL DATA
Operating temperature range -20...+80°C over 40°C apply a derating of 0.04A/°C
Input/Output isolation 2.5 kVac / 60 s
Isolation between output terminal blocks 1 kVac / 60 s (between open contact poles)
Protection degree IP 00 IEC 529, EN60529
Surge category/degree of pollution III / 2
Reference Standards IEC 664-1, DIN VDE 0110.1
Power/status indicator Green LED / Yellow LED
Connection type 2.5 mm2 fixed screw terminal blocks and FLAT connector
Housing material UL94V-0 plastic
Approximate weight 207 g 379 g 756 g
Mounting information on rails, side by side
16 relay module
MOUNTING ACCESSORIES
Mounting rail compliant with IEC60715/TH35 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
Spare part relay (1) Cat. No. 8904404
Jumper —

116
Solid state 24 Vdc
relay modules with
electronic protection
• Nominal output current 8 x 2.5 A / 5 - 33 Vdc
• outputs protected against short-circuit, overload, 93
over temperature and surge;
• Negative common 12-24 Vdc input, 8 status LEDs
K1 and K8 70 Item available until supplies last
• 8 “output OK” LED indicators, reverse polarity
protection diode on input and output 70
• Width 70 mm

NOTES BLOCK DIAGRAM


(1) Maximum current depends on the number of
simultaneously active outputs and the ambient tem-        

perature; the value shown was measured with 4


active and 4 non-active outputs. 

(2) Outputs are protected against short-circuit/over-


load and overtemperature; safety activation is in- 
dicated by a dimly lit or off output side status LED;




once the short-circuit/overload is eliminated, the


output is restored automatically.
     

VERSIONS Cat. No. XCOP082


4 relay module
8 relay module COP082
16 relay module
INPUT TECHNICAL DATA
Input voltage 5-24 Vdc (range 4.2…32 Vdc) negative common
Signal 1 input level > 3.5 Vdc
Signal 0 input level < 3.5 Vdc
Power consumption (1 channel) 5 mA ±10%.
Commutation frequency 500 Hz

OUTPUT TECHNICAL DATA


Output voltage 12-24 Vdc, (range 5…32 Vdc) negative common
Permanent load current 8 x 2.5 A at 25°C (1)
Max current 4.4 A
Leakage current with signal 0 25 µA max at 24Vdc
OFF/ON switching time 200 Hz (T on < 500 µs / T off < 500 µs)
Protection circuit electronic short-circuit/overload/thermal (2)
Min. applicable load 5.2 Vdc/ 100 mA
GENERAL TECHNICAL DATA
Operating temperature range -20...-60°C (with thermal protection) (2)
Input/Output isolation 2.5 kVac / 60 s
Isolation between output terminal blocks 1 kVac / 60 s (between open contact poles)
Protection degree IP 00 IEC 529, EN60529
Surge category/degree of pollution III / 2
Reference Standards IEC 664-1, DIN VDE 0110.1
Power/status indicator Green LED (DC OK) / Yellow LED (output OK)
Connection type 2.5 mm² fixed screw terminal blocks
Housing material UL94V-0 plastic
Approximate weight
Mounting information on rails, side by side

MOUNTING ACCESSORIES
Mounting rail compliant with IEC60715/TH35 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
Spare part relay (1) —
Jumper —

117
These tables are used for quickly identifying items and verifying whether all of the product’s technical details satisfy the set requirements.

D-Sub / Terminal blocks Diode-holders


Dimensions Dimensions
Versions Type Type Cat. No. Page Versions Type Type Cat. No. Page
AxBxC AxBxC
9 poles 37x66x93 (6) ISD09FM XISD09FM 119 8 diodes 25x60x76 (4) CDM08CS XCDM08CS 124
37x66x93 (5) ISD09PF XISD09PF 119 45x65x93 (1) CDM08AC XCDM08AC 125
37x66x93 (8) ISD09PM XISD09PM 119 45x65x93 (2) CDM08CC XCDM08CC 125
15 poles 47x66x93 (6) ISD15FM XISD15FM 119 16 diodes 50x65x93 (4) CDM16CS XCDM16CS 124
47x66x93 (5) ISD15PF XISD15PF 119 92x65x93 (1) CDM16AC XCDM16AC 125
47x66x93 (8) ISD15PM XISD15PM 119 92x65x93 (2) CDM16CC XCDM16CC 125
25 poles 70x66x93 (6) ISD25FM XISD25FM 119 24 diodes 71x65x93 (4) CDM24CS XCDM24CS 124
70x66x93 (5) ISD25PF XISD25PF 119 137x65x93 (1) CDM24AC XCDM24AC 125
70x66x93 (8) ISD25PM XISD25PM 119 137x65x93 (2) CDM24CC XCDM24CC 125
57x80x93 (5) (11) CPD25F XCPD25F 119 137x65x93 (2) CDM24CC XCDM24CC 125
57x80x93 (8) (11) CPD25M XCPD25M 119
37 poles 107x66x93 (6) ISD37FM XISD37FM 119
107x66x93 (5) ISD37PF XISD37PF 119 Lamp tester and LED tester
107x66x93 (8) ISD37PM XISD37PM 119
Dimensions
77x80x93 (5) (11) CPD37F XCPD37F 120 Versions Type Type Cat. No. Page
AxBxC
77x80x93 (8) (11) CPD37M XCPD37M 120
8 diodes 45x65x93 (1) CLT08AC XCLT08AC 126
50 poles 92x80x93 (5) (11) CPD50F XCPD50F 120
45x65x93 (2) CLT08CC XCLT08CC 126
92x80x93 (8) (11) CPD50M XCPD50M 120
45x65x93 CLP08CC XCLP08CC 127
16 diodes 92x65x93 (1) CLT16AC XCLT16AC 126
92x65x93 (2) CLT16CC XCLT16CC 126
92x65x93 CLP16CC XCLP16CC 127

Flat / Terminal blocks Component holders


Dimensions Dimensions
Versions Type Type Cat. No. Page Versions Type Type Cat. No. Page
AxBxC AxBxC
10 poles 42x66x93 (8) (7) IF10PML XIF10PML 120 8 components 25x66x93 (10) CCM08SV XCCM08SV 123
14 poles 48x66x93 (8) (7) IF14PML XIF14PML 121 8 components 25x66x93 (3) CCM08CV XCCM08CV 123
16 poles 58x66x93 (8) (7) IF16PML XIF16PML 121 16 compo- 47x66x93 (10) CCM16SV XCCM16SV 123
20 poles 70x66x93 (8) (7) IF20PML XIF20PML 121 nents
47x80x93 (8) (11) CPC20M XCPC20M 122 16 compo- 47x66x93 (3) CCM16CV XCCM16CV 123
26 poles 86x66x93 (8) (7) IF26PML XIF26PML 121 nents
57x80x93 (8) (11) CPC26M XCPC26M 122 24 compo- 70x66x93 (10) CCM24SV XCCM24SV 123
34 poles 107x66x93 (8) (7) IF34PML XIF34PML 121 nents
70x80x93 (8) (11) CPC34M XCPC34M 122
40 poles 122x66x93 (8) (7) IF40PML XIF40PML 121
77x80x93 (8) (11) CPC40M XCPC40M 122
50 poles 92x80x93 (8) (11) CPC50M XCPC50M 122
60 poles 107x80x93 (8) (11) CPC60M XCPC60M 122
64 poles 117x80x93 (8) (11) CPC64M XCPC64M 122

Key (6) female + male connector


(1) common anode (7) with LED
(2) common cathode (8) male connector
(3) with common (9) feed-throughs with Faston
(4) feed-through (10) feed-throughs with terminal blocks
(5) female connector (11) small size

118
Passive interfaces
(D-Sub/terminal blocks)
ISD Series
C C C

A A A

B B B

NOTES BLOCK DIAGRAM


The modules allow signals originating on a wire with a d-sub connec-
tor to be transferred to terminal blocks. 1 2 9 15 25 37 50 1 2 9 15 25 37 50 1 2 9 15 25 37
Numbering is “pin-to-pin”.
(1) Version made to order (not kept in stock); contact our sales
office for availability.

1 2 9 15 25 37
1 2 9 15 25 37 50 1 2 9 15 25 37 50
1 2 9 15 25 37

VERSIONSDIMENSIONS male female male + female


 (A x B x C) Type Cat. No. Type Cat. No. Type Cat. No.
9 poles 37x66x93 ISD09PM (1) XISD09PM ISD09PF (1) XISD09PF ISD09FMXISD09FM
15 poles 47x66x93 ISD15PM (1) XISD15PM ISD15PF (1) XISD15PF ISD15FMXISD15FM
25 poles 70x66x93 ISD25PM (1) XISD25PM ISD25PF (1) XISD25PF ISD25FMXISD25FM
37 poles 107x66x93 ISD37PM (1) XISD37PM ISD37PF (1) XISD37PF ISD37FMXISD37FM
GENERAL TECHNICAL DATA
Applicable voltage 0...50 Vac / 0...75 Vdc 0...50 Vac / 0...75 Vdc 0...50 Vac / 0...75 Vdc
Applicable current 2 A max 2 A max 2 A max
Operating temperature range -20…+60°C -20…+60°C -20…+60°C
Protection degree IP00 IEC529; EN60529 IP00 IEC529; EN60529 IP00 IEC529; EN60529
Reference Standards IEC 664-1; DIN VDE 0110.1 IEC 664-1; DIN VDE 0110.1 IEC 664-1; DIN VDE 0110.1
Degree of pollution 2 2 2
Surge category II II II
Housing material UL94V-0 polyamide UL94V-0 polyamide UL94V-0 polyamide
Connection type 2.5 mm² fixed screw terminal blocks 2.5 mm² fixed screw terminal blocks 2.5 mm² fixed screw terminal blocks
Mounting information vertical on rails, side by side vertical on rails, side by side vertical on rails, side by side

MOUNTING ACCESSORIES
Mounting rail compliant with IEC60715/TH35 PR/3/AC - PR/3/AS
Mounting rail type according to IEC60715/G32 PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
Jumperblack —

119
Passive interfaces
(D-Sub/terminal blocks)
CPD Series
C C
• Small size

A A

B B

NOTES BLOCK DIAGRAM


The modules allow signals originating on a wire with a d-sub connec-
tor to be transferred to terminal blocks. 1 2 9 15 25 37 50 1 2 9 15 25 37 50
Numbering is “pin-to-pin”.
(1) Version made to order (not kept in stock); contact our sales office
for availability.

1 2 9 15 25 37 50 1 2 9 15 25 37 50

VERSIONSDIMENSIONS male female


 (A x B x C) Type Cat. No. Type Cat. No.
25 poles 57x80x93 CPD25MXCPD25M CPD25FXCPD25F
37 poles 77x80x93 CPD37MXCPD37M CPD37FXCPD37F
50 poles 92x80x93 CPD50M (1) XCPD50M CPD50F (1) XCPD50F

GENERAL TECHNICAL DATA


Applicable voltage 0...50 Vac / 0...75 Vdc
Applicable current 2 A max
Operating temperature range -20…+60°C
Protection degree IP00 IEC529; EN60529
Reference Standards IEC 664-1; DIN VDE 0110.1
Degree of pollution 2
Surge category II
Housing material UL94V-0 polyamide
Connection type 2.5 mm² fixed screw terminal blocks
Mounting information vertical on rails, side by side

MOUNTING ACCESSORIES
Mounting rail compliant with IEC60715/TH35 PR/3/AC - PR/3/AS
Mounting rail type according to IEC60715/G32 PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
Jumperblack —

120
Passive interfaces
(Flat-cable/terminal
blocks) IF Series
C
• With warning light

NOTES BLOCK DIAGRAM


The modules allow signals originating on a flat cable to be transferred
to terminal blocks using IDC connectors (with isolation perforation). 1 2 20 26 34 40 50 C
Numbering is “pin-to-pin”.
(1) Version made to order (not kept in stock); contact our sales office
for availability.
(2) Warning LEDs are configured for a nominal voltage of 24 Vdc and
negative common

1 2 20 26 34 40 50

VERSIONSDIMENSIONS with LED


 (A x B x C) Type Cat. No.
10 poles 42x66x93 IF10PML (1) XIF10PML
14 poles 48x66x93 IF14PML (1) XIF14PML
16 poles 58x66x93 IF16PML (1) XIF16PML
20 poles 70x66x93 IF20PML (1) XIF20PML
26 poles 86x66x93 IF26PML (1) XIF26PML
34 poles 107x66x93 IF34PML (1) XIF34PML
40 poles 122x66x93 IF40PML (1) XIF40PML

GENERAL TECHNICAL DATA


Applicable voltage 12...24 Vdc ±10% (2)
Applicable current 750 mA max
Operating temperature range -20…+60°C
Protection degree IP00 IEC529; EN60529
Reference Standards IEC 664-1; DIN VDE 0110.1
Degree of pollution 2
Surge category II
Housing material UL94V-0 polyamide
Connection type 2.5 mm² fixed screw terminal blocks
Mounting information vertical on rails, side by side

MOUNTING ACCESSORIES
Mounting rail compliant with IEC60715/TH35 PR/3/AC - PR/3/AS
Mounting rail type according to IEC60715/G32 PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
Jumperblack —

121
Passive interfaces
(Flat-cable/terminal
blocks) CPC Series
C
• Small size

NOTES BLOCK DIAGRAM


The modules allow signals originating on a flat cable to be transferred
1 2 20 26 34 40 50
to terminal blocks using IDC connectors (with isolation perforation).
Numbering is “pin-to-pin”.
(1) Version made to order (not kept in stock); contact our sales office
for availability.

1 2 20 26 34 40 50

VERSIONSDIMENSIONS Without LED


 (A x B x C) Type Cat. No.
20 poles 47x80x93 CPC20MXCPC20M
26 poles 57x80x93 CPC26MXCPC26M
34 poles 70x80x93 CPC34M (1) XCPC34M
40 poles 77x80x93 CPC40MXCPC40M
50 poles 92x80x93 CPC50M (1) XCPC50M
60 poles 107x80x93 CPC60M (1) XCPC60M
64 poles 117x80x93 CPC64M (1) XCPC64M

GENERAL TECHNICAL DATA


Applicable voltage 0...50 Vac / 0...75 Vdc
Applicable current 750 mA max
Operating temperature range -20…+60°C
Protection degree IP00 IEC529; EN60529
Reference Standards IEC 664-1; DIN VDE 0110.1
Degree of pollution 2
Surge category II
Housing material UL94V-0 polyamide
Connection type 2.5 mm² fixed screw terminal blocks
Mounting information vertical on rails, side by side

MOUNTING ACCESSORIES
Mounting rail compliant with IEC60715/TH35 PR/3/AC - PR/3/AS
Mounting rail type according to IEC60715/G32 PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
Jumperblack —

122
Component-holder
modules CCM Series
• Small size
C C

A A
B B

NOTES BLOCK DIAGRAM


Component-holder modules allow for the mounting of electronic com-
ponents (diodes, resistors, zener, etc.) by the client. C 2 4 6 8 16 15 14 13 12 11 10 9
Various configurations are available, with terminal block or flat plug
connection and with different sized holes for leading wires of com-
ponents.
(1) Version made to order (not kept in stock), for information contact
our sales office.

C 1 3 5 7 1 2 3 4 5 6 7 8

VERSIONSDIMENSIONS with common single feed-through


 (A x B x C) Type Cat. No. Type Cat. No.
4 components (1) 25x66x93 — —
8 components (1) 25x66x93 — CCM08SVXCCM08SV
8 components (1) 47x66x93 — —
8 components (1) 25x55x93 CCM08CVXCCM08CV —
12 components (1) 70x66x93 — —
16 components (1) 47x66x93 CCM16CVXCCM16CV CCM16SVXCCM16SV
24 components (1) 70x66x93 — CCM24SV  XCCM24SV

GENERAL TECHNICAL DATA


Applicable voltage 0...220 V ±10% 0...100 V ±10%
Applicable current 5 A channel / 15 A on common 4 A max. (on common)
Operating temperature range -20…+60°C -20…+60°C
Protection degree IP00 IEC529; EN60529 IP00 IEC529; EN60529
Reference Standards IEC 664-1; DIN VDE 0110.1 IEC 664-1; DIN VDE 0110.1
Degree of pollution 2 2
Surge category II II
Housing material UL94V-0 polyamide UL94V-0 polyamide
Connection type 2.5 mm² fixed screw terminal blocks 2.5 mm² fixed screw terminal blocks
Mounting information vertical on rails, side by side vertical on rails, side by side

MOUNTING ACCESSORIES
Mounting rail compliant with IEC60715/TH35 PR/3/AC - PR/3/AS
Mounting rail type according to IEC60715/G32 PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
Jumperblack —

123
Feed-through diode
modules CDM Series
C C C

A A A
B B B

NOTES BLOCK DIAGRAM

1A 2A 3A 4A 5A 6A 7A 8A 16A 24A

1C 2C 3C 4C 5C 6C 7C 8C 16C 24C

VERSIONSDIMENSIONS feed-through diodes


 (A x B x C) Item Cat. No.
8 diodes 25x60x76 CDM08CSXCDM08CS
16 diodes 50x65x93 CDM16CSXCDM16CS
24 diodes 71x65x93 CDM24CSXCDM24CS

GENERAL TECHNICAL DATA


Applicable voltage 0…100 V ±10%
Applicable current 1 A max
Diodes used 1N4007
Max inverse voltage 1000 V
Operating temperature range -20…+60°C
Protection degree IP00 IEC529; EN60529
Reference Standards IEC 664-1; DIN VDE 0110.1
Degree of pollution 2
Surge category II
Housing material UL94V-0 polyamide
Connection type 2.5 mm² fixed screw terminal blocks
Mounting information vertical on rails, side by side

MOUNTING ACCESSORIES
Mounting rail compliant with IEC60715/TH35 PR/3/AC - PR/3/AS
Mounting rail type according to IEC60715/G32 PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
Jumperblack —

124
Diode modules
with common CDM Series

A
B

NOTES BLOCK DIAGRAM

1 3 5 7 15 23 1 3 5 7 15 23

C 2 4 6 8 16 24 C 2 4 6 8 16 24

VERSIONSDIMENSIONS common anode common cathode


 (A x B x C) Type Cat. No. Type Cat. No.
8 diodes 45x65x93 CDM08ACXCDM08AC CDM08CCXCDM08CC
16 diodes 92x65x93 CDM16ACXCDM16AC CDM16CCXCDM16CC
24 diodes 137x65x93 CDM24ACXCDM24AC CDM24CCXCDM24CC

GENERAL TECHNICAL DATA


Applicable voltage 0…220 V ±10%
Applicable current 1 A channel / 15 A on common
Operating temperature range 1N4007
Diodes used 1000 V
Max inverse voltage -20…+60°C
Protection degree IP00 IEC529; EN60529
Reference Standards IEC 664-1; DIN VDE 0110.1
Degree of pollution 2
Surge category II
Housing material UL94V-0 polyamide
Connection type 2.5 mm² fixed screw terminal blocks
Mounting information vertical on rails, side by side

MOUNTING ACCESSORIES
Mounting rail compliant with IEC60715/TH35 PR/3/AC - PR/3/AS
Mounting rail type according to IEC60715/G32 PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
Jumperblack —

125
LED testing modules
CLT Series
• Compact dimensions
• Integrated limitation resistance C
• Suitable only for LEDs without limitation resistance
• Not suitable for LED lamps fitted with an integrated
limitation circuit
A
B

NOTES BLOCK DIAGRAM


(1) LED test is conducted on a negative signal on the common
(2) LED test is conducted on a positive signal on the common
(3) Version made to order (not kept in stock); contact our sales office
for availability.

Some LED lamps are equipped with an internal electronic circuit to


adjust the rated voltage. In some cases this circuit will not work cor-
rectly if connected in series to a diode, therefore these lamps are not
suitable for use with LED test modules or LED test.

VERSIONSDIMENSIONS common negative(1) common positive(2)


 (A x B x C) Type Cat. No. Type Cat. No.
8 channels 45x65x93 CLT08AC (3) XCLT08AC CLT08CC (3) XCLT08CC
16 channels 92x65x93 CLT16AC (3) XCLT16AC CLT16CC (3) XCLT16CC

GENERAL TECHNICAL DATA


Applicable voltage 24 Vdc max 30 Vdc
Single channel current 5 mA at 24 Vdc
Diodes used 1N4007
Limitation resistance 4.7 kΩ 1/4 W ±5%
Max inverse voltage 1000 V
Operating temperature range -20…+45°C
Housing material UL94V-0 polyamide
Protection degree IP 00 IEC529, EN60529
Connection type 2.5 mm2 fixed screw
Mounting information vertical on rails, side by side

MOUNTING ACCESSORIES
Mounting rail compliant with IEC60715/TH35 PR/3/AC – PR/3/AC/ZB – PR/3/AS – PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
Jumperblack —

126
Lamp testing modules
CLP Series
• Compact dimensions
• Suitable for LED lamps with limitation resistance C

A
B

NOTES BLOCK DIAGRAM


If using modules in alternating current, power is halved due to the
presence of rectifier diodes.
(1) Lamp test is conducted on a negative signal on the common
(2) Lamp test is conducted on a positive signal on the common

VERSIONSDIMENSIONS common negative(1) common positive(2)


 (A x B x C) Type Cat. No. Type Cat. No.
8 channels 45x65x93 CLP08CCXCLP08CC
16 channels 92x65x93 CLP16CCXCLP16CC

GENERAL TECHNICAL DATA


Applicable voltage 230 Vac/dc
Single channel current 100 mA at 120 Vac/dc;
50 mA at 230 Vac/dc
Diodes used 1N4007
Limitation resistance 0
Max inverse voltage 1000 V
Operating temperature range -20…+45°C
Housing material UL94V-0 polyamide
Protection degree IP 00 IEC529, EN60529
Connection type 2.5 mm2 fixed screw
Mounting information vertical on rails, side by side

MOUNTING ACCESSORIES
Mounting rail compliant with IEC60715/TH35 PR/3/AC – PR/3/AC/ZB – PR/3/AS – PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
Jumperblack —

127
Electronic circuit housing
CH Series
CH-B12.5
• Modular in 3 sizes

CH-C
CH-S CH-CA
CH-C10 CH-C22.5 CH-C32.5

NOTES BLOCK DIAGRAM


(1) M aximum height of components measured
between circuit and cover

VERSIONS Type Cat. No. APPLICATIONS


12.5 mm DIN-rail mounting base CH-B12.5 XBB125 Electronic circuit for housing CH Series
10 mm cover CH-C10 XBC010 With its CH (Cabur Housing) series containers, Cabur offers a modular sys-
22.5 mm cover CH-C22.5 XBC225 tem for creating three different sized boxes (22.5 mm, 35 mm and 45 mm)
32.5 mm cover CH-C32.5 XBC325 made up of eight easily assemble parts.
openable front closure CH-S XBS000 The circuit can measure up to 102 x 74 mm and can be inserted onto four
aerated closure CH-CA XBCA00 columns in the base which hold it in place.
non-aerated closure CH-C XBC000 The circuit can be additionally secured with a 2.2 x 4.5 mm self-tapping
GENERAL TECHNICAL DATA screw, to be screwed into the central column, which also enables the circuit
Material UL94V-0 polyamide to be smaller in size.
Colour RAL 5014 Conductor connections are applied using 2.5 mm removable terminal
blocks, which are easily available.
Temperature max 80 °C
16 connection poles are used, with a clearance of 5.08 mm on each side
Dissipated power max 7 W
and 10 mm on the front.
Protection degree up to IP30
The CH-S front closure has an openable inspection window for access
Number of poles per side 16 +16 (5.08) to inside the circuit for procedures on potentiometers, jumpers and
Number of front poles 10 (5.08) microswitches.
Mounting information The side closures have a number of incisions which enable them to be cut
off with scissors, at a clearance of 5.08 mm, avoiding the expensive grinding
typical of other models on the market.
MOUNTING ACCESSORIES
Mounting rail compliant with IEC60715/TH35-7.5 PR/3/AC, PR/3/AS Housing requires the following components:
Mounting rail compliant with IEC60715/G32 —
Jumperred — • 1 CH-B12.5 base width 12.5 mm
white —
blue — • 1 cover (3 available sizes)
CH-C10 width 10 mm
CH-C22.5 width 22.5 mm
CH-C32.5 width 32.5 mm

(the total housing width is obtained by adding the width of the base (12.5
mm) to the width of the cover selected from the 4 available sizes)

• 1 front closure, available in two versions:


CH-S openable window
CH-CF fixed

• 2 side closures, available in two versions:


CH-C without aeration holes
CH-CA with aeration holes

Max
internal CH-CA
height
CH-B12.5 CH-C10 CH-C22.5 CH-C32.5 CH-S
CH-C
(1)
19.1 mm 1 1 1 2
31.6 mm 1 1 1 2
41.6 mm 1 1 1 2

128
Electronic circuit housing
CK Series
• Expandable cards with 6 mm clearance
• 6 x 2.5 mm2 spring terminal blocks on both the base and
the expansions
• Jumper can be connected on all 4 levels
• Openable front inspection window

NOTES BLOCK DIAGRAM


(1) Includes 6 spring terminal blocks with weldable CKB and CKBG CKBX2 CKPT CKS CKPCB
contact
(2) The final module must always be protected with
the CK/PT terminal wall to ensure protection
degree IP20.

VERSIONS Type Cat. No. APPLICATIONS


base housing CKB (1) XCKB With its CK series housing, Cabur offers a modular system for creating ter-
base housing with ground contact CKBG (1) XCKBG minal blocks of gradually increasing widths for housing simple components
expansion module CKBX2 (1) XCKX2 such as diodes and resistors or more complex circuits with or without the
end section CK/PT XCKPT support of a printed circuit board.
openable inspection window CK/S XCKS Housing requires the following components:
printed circuit board CK/PCB 8901028 • one base housing available in two versions: CKB and CKBG, the latter sup-
GENERAL TECHNICAL DATA plied with an electrical contact to the metal rail for connecting the internal
Voltage distributable to the jumper 230 Vac/dc ± 10% circuit to ground. The rail ground contact can carry an impulse current of
Current distributable to the jumper ≤ 24 A 5 KA (impulse 8/20). Both models have an external width of 6 mm and
Operating temperature range -40...+ 100°C an internal width of 5 mm and have 6 spring connections, 4 of which are
connectable to a jumper.
Protection degree (2) IP20 IEC529 EN60529
• one or more CKBX2 expansion cards similar to the standard model, i.e.
Connection terminal blocks 2.5 mm2, AWG26-14 spring
with an external width of 6 mm and a central cavity that allows bulky
Housing material UL94V-0 polyamide
components to overlap the base outline, can also be supplied with a
Approximate weight 20 g (CKB, CKBG), 15 g (CKX2, CK/PT) 6-connection expansion, 4 of which connectable to a jumper;
20 g (CK/PT), 1 g (CK/S), 5 g (CK/PCB) • available with the CK/S openable inspection window for frontal closure; the
Jumper PTC/CK/42 cat. no. PTCCK42 (42 poles)
opening is in any case sized to ensure protection degree IP20 even without
Marking tag neutral CNU/8/030 cat. no. NU0851 using the inspection window;
 • the final module must be provided with the CK/PT end section, which
Mounting information on rails ensures protection degree IP20;
MOUNTING ACCESSORIES • also available with the CK/PCB printed strip board, useful for custom appli-
Mounting rail compliant with IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB cations in which low volumes make it infeasible to produce a dedicated
Mounting rail compliant with IEC60715/G32 — printed circuit board or for creating affordable prototypes.
Jumperred —
white —
blue —

Ground contact on CKBG CKBX2 CKB CK/PCB

129
“CK” Series accessories
PTC/CK/42 jumper
Notes:
(1) Example of a bridge cut into nine poles
(1)
(2) Protection degree refers to the bridge installed following the
applicable instructions
(3) Capacity allows for a maximum current of 32 A, limited to the
capacity of the 24 A terminal block, therefore in a plug-in jumper
of e.g. 11 poles (1 common and 10 distribution) 2.4 A can be
distributed per pole. VERSIONS Type Cat. No.
PTC/CK/42 PTCCK42

GENERAL TECHNICAL DATA


Protection degree (2) IP20 IEC529; EN60529
Number of poles 42
Pitch 6 mm
Bridge current capacity (3) 32 A
Isolation colour —
Material copper-tin alloy
Approximate weight 27 g (42 poles)

“CW..7” Series accessories


CWBK Series jumpers

VERSIONS Type Cat. No. Type Cat. No. Type Cat. No.
CWBK 7-0802 X766802 CWBK 7-0803 X766803 CWBK 7-0804 X766804

GENERAL TECHNICAL DATA


Protection degree IP20 IEC529; EN60529 IP20 IEC529; EN60529 IP20 IEC529; EN60529
Number of poles 16 16 16
Pitch 6.2 mm 6.2 mm 6.2 mm
Jumper current capacity 16 A 16 A 16 A
Isolation colour red white blue
Material — — —
Approximate weight 4g 4g 4g

“CWRE” Series accessories


Jumpers CWBK Series

VERSIONS Type Cat. No.


CWBK 7-0813 X766813

GENERAL TECHNICAL DATA


Protection degree IP20 IEC529; EN60529
Number of poles 20
Pitch 6.2 mm
Jumper current capacity 16 A
Isolation colour blue
Material —
Approximate weight 6g

130
“CM” Series accessories CMB
Series jumpers

VERSIONS Type Cat. No. Type Cat. No.


CMB16B XCMB16B CMB27B XCMB27B

GENERAL TECHNICAL DATA


Protection degree IP20 IEC529; EN60529 IP20 IEC529; EN60529
Number of poles 8 8
Pitch 16 mm 27 mm
Jumper current capacity 16 A 16 A
Isolation colour black black
Material — —
Approximate weight 3g 3g

Marking systems
Notes:
White polyamide marking tags to number the
terminal blocks of the CK Series cards and
CWRE Series converters. To be directly inserted
in dedicated holders before or after rail mount-
ing preparation.
They come in packages of 15 cards of 100
marking tags each, for a total of 1,500 mark-
ing tags.
The table shows only blank marking tags, avail-
able in packages of 1,500 pieces each, which
can be written on manually using special pens
or printed using an industrial marking system.
In particular, the marking tags shown here can
be printed using the innovative CaburJet
Type CNU/8/51 Cat. No. NU0851 Type NUPUTUK50 Cat. No. NUPUTUK50
system and with the CaburPlot plotter.
In addition to blank marking tags, CNU/8/51
preprinted marking tags are also available with Description Type Cat. no.
alpha-numeric characters and with the most Marking tags for marking CK Series cards CNU/8/51 NU0851
common electrical symbols.
For more information, please consult the Marking tags for marking CWRE Series converters NUPUTUK50 NUPUTUK50
Industrial Marking Systems catalogue.

Power supply
mounting bracket

VERSIONS Type Cat. No. DIMENSIONS


CDIWMP XCDIWMP
180
155
GENERAL TECHNICAL DATA 9 9 10 10 9 7

Type of material P13-FE00 aluminium


Treatment Sendzimir zinc coating
10 10
38

17

Mounting information screws or rivets

40
9
2

131
DIN rail clamp

DIMENSIONS

VERSIONS Type Cat. No. Type Cat. No.


CDIN-2 XCDIN2 CDIN-4 XCDIN4

GENERAL TECHNICAL DATA


Type of material P13-FE00 aluminium
Treatment black zinc coating —
Mounting information screws or rivets screws or rivets
Mounting rail compliant with IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail compliant with IEC60715/G32 — —

DIMENSIONS
38 9.70 38 10

20 20
10
10

50
97.50

78

95.10

VERSIONS Type NAME DATE SIG.


Cat. No. Type Via Luserte Sud 8
DRAWN
NAME DATE
25.02.2011
Cat. No.
CDIN-6 XCDIN6 CDINM45 XCDINM45
Switzerland - 6572 Quartino DESIGN
DRAWN 25.02.2011 CHECKED
DESIGN
APPROVED SIZE REV. 4.5 DWG. NAME: DIN-M V4.5
CHECKED all material ROHS compliant SURF. TEXTURE Material
Use FINE GRADE as per EN22768-1 SCALE SHEET 1 OF 1
APPROVED SIZE REV. 3.0 DWG. NAME: DIN-M V3.0
SURF. TEXTURE Material

GENERAL TECHNICAL DATA


Use FINE GRADE as per EN22768-1 Steel Sheet th. 1mm SCALE SHEET 1 OF 1

Type of material P13-FE00 P13-FE00


Treatment white zinc coating zinc coating
Mounting information screws or rivets screws
Mounting rail compliant with IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail compliant with IEC60715/G32 — —

132
Mounting rails
• conforming to IEC 60715/TH35 - 7.5
• conforming to IEC 60715/TH35 - 15
• supports for TH/35 rail

DESCRIPTION TYPE/CAT. NO. DIAGRAMS

Rail compliant with IEC 60715/TH35 - 7.5 PR/3/AC


in passivated steel
Cat. No. PR003

Rail compliant with IEC 60715/TH35 - 7.5 PR/3/AC/ZB


in white zinc-plated steel
“SENDZMIR” system Cat. No. PR903

Rail compliant with IEC 60715/TH35 - 7.5 PR/3/AS


in passivated steel with slots
Cat. No. PR005

Rail compliant with IEC 60715/TH35 - 7.5 PR/3/AS/ZB


in white zinc-plated steel
“SENDZMIR” system with slots Cat. No. PR905

Rail compliant with IEC 60715/TH35 - 15 PR/3/PP


in passivated steel
Cat. No. PR007

Rail compliant with IEC 60715/TH35 - 15 PR/3/PP/ZB


in white zinc-plated steel
“SENDZMIR” system Cat. No. PR907

Rail compliant with IEC 60715/TH35 - 15 PR/3/PA


in passivated steel with slots
Cat. No. PR006

Rail compliant with IEC 60715/TH35 - 15 PR/3/PA/ZB


in white zinc-plated steel
“SENDZMIR” system with slots Cat. No. PR906

Support for rails IEC 60715/TH35 ACI121017


in nickel plated steel with rapid mounting system
4 MA Cat. No. Z121017

Support for rails IEC 60715/TH35 ACI121019


in nickel plated steel with rapid mounting system
5 MA Cat. No. Z121019

133
Mounting rails
• conforming to IEC 60715/TH35 - 7.5 “G32” type
• conforming to IEC 60715/TH15 - 5.5

DESCRIPTION TYPE/CAT. NO. DIAGRAMS

Rail compliant with IEC 60715 “G32” type PR/DIN/AC


in passivated steel
Cat. No. PR001

Rail compliant with IEC 60715 “G32” type PR/DIN/AC/ZB


in white zinc-plated steel
“SENDZMIR” system Cat. No. PR901

Rail compliant with IEC 60715 “G32” type PR/DIN/AS


in passivated steel with slots
Cat. No. PR004

Rail compliant with IEC 60715 “G32” type PR/DIN/AS/ZB


in white zinc-plated steel
“SENDZMIR” system with slots Cat. No. PR904

Rail compliant with IEC 60715 “G32” type PR/DIN/AL


in aluminium
Cat. No. PR002

Rail compliant with IEC 60715/TH15 - 5.5 PR/2/AC


in passivated steel
Cat. No. PR009

Rail compliant with IEC 60715/TH15 - 5.5 PR/2/AC/ZB


in white zinc-plated steel
“SENDZMIR” system Cat. No. PR909

Rail compliant with IEC 60715/TH15 - 5.5 PR/2/AS


in passivated steel with slots
Cat. No. PR010

Rail compliant with IEC 60715/TH15 - 5.5 PR/2/AS/ZB


in white zinc-plated steel
“SENDZMIR” system with slots Cat. No. PR910

134
Type index
ID NUMBER PAGE ID NUMBER PAGE ID NUMBER PAGE ID NUMBER PAGE ID NUMBER PAGE
AR6 42 CM1A012 91 CSD30E 12 CWBK7-0802 130 ISD09FM 119
CAPIPO3 67 CM1A024 91 CSD30F 12 CWBK7-0803 130 ISD09PF 119
CCIS2 79 CM1A120 91 CSD50B 13 CWBK7-0804 130 ISD09PM 119
CCM08CV 123 CM1A230 91 CSD70C 14 CWBK7-0813 130 ISD15FM 119
CCM08SV 123 CM1C012 88 CSF120C 18 CWCV7-6184 83 ISD15PF 119
CCM16CV 123 CM1C024 88 CSF120CP 18 CWNAA7-0539 69 ISD15PM 119
CCM16SV 123 CM1C048 88 CSF120DP 18 CWNFA6-0524 82 ISD25FM 119
CCM24SV 123 CM1C110 88 CSF240C 19 CWOT6-2082 113 ISD25PF 119
CDIN-2 132 CM1S024 108 CSF240CP 19 CWOT6-2083 112 ISD25PM 119
CDIN-4 132 CM1S024E 108 CSF240DP 19 CWPAA7-0526 73 ISD37FM 119
CDIN-5 132 CM1T024 109 CSF30C 16 CWPAA7-0527 73 ISD37PF 119
CDINM45 132 CM1T024E 109 CSF500C 20 CWPT6-0816 77 ISD37PM 119
CDM08AC 125 CM2A012 92 CSF500D 20 CWRE7-0842 95 LCONALSFDT 74
CDM08CC 125 CM2A024 92 CSF5-65 21 CWRE7-0845 95 LCONTADFDT 75
CDM08CS 124 CM2A120 92 CSF85B 17 CWRE7-0846 95 LCONTLSFDT 76
CDM16AC 125 CM2A230 92 CSF85C 17 CWRE7-0847 95 LCONZBUSB 74
CDM16CC 125 CM2C012 89 CSF85CP 17 CWRE7-0848 95 MBC2K 51
CDM16CS 124 CM2C024 89 CSG2401C 37 CWTH6-0844 78 NUPUTUK50 131
CDM24AC 125 CM2C048 89 CSG2401D 37 CWUAA6-0516 68 O332060 107
CDM24CC 125 CM2C110 89 CSG2401G 38 F03DKBG5B 61 O332240 107
CDM24CS 124 CM4C024 90 CSG2401R 38 F03DPCG5C 62 PTC/CK/42 130
CEP-BCB 53 CMB27B 131 CSG481C 33 F06DKBG5B 61 R161E24 97
CEP-BCR 53 CNU/8/51 131 CSG500C 34 F06DPCG5C 62 R161EAD 98
CEP-D1 53 COP082 117 CSG500G 34 F07TDVST2 55 R161S24F 116
CEP-D2 53 CPC20M 122 CSG720C 35 F100TDVST2 55 R161U24F 99
CEP-MTW 53 CPC26M 122 CSG720D 35 F100TYT8 59 R162E24 100
CEP-RCC 53 CPC34M 122 CSG960C 36 F10TYG9 60 R162EAD 101
CEP-RCP 53 CPC40M 122 CSG960D 36 F12DKBG5B 61 R162S24 114
CEP-SS 53 CPC50M 122 CSG960G 36 F12DPCG5C 62 R162T24 115
CH-B12.5 128 CPC60M 122 CSL120C 24 F150TDS84C 56 R41E24 97
CH-C 128 CPC64M 122 CSL240C 25 F16DKCG5B 61 R41EAD 98
CH-C10 128 CPD25F 120 CSL481C 26 F16DPCG5C 62 R41S24F 116
CH-C22.5 128 CPD25M 120 CSL85C 23 F16TDVST2 55 R41U24F 99
CH-C32.5 128 CPD37F 120 CSR50U 49 F16TYT8 59 R42E24 100
CH-CA 128 CPD37M 120 CSU0120S 45 F180TDS84C 56 R42EAD 101
CH-S 128 CPD50F 120 CSU240S 46 F200TDDS84C 57 R42S24 114
CI-NPN/PNP 84 CPD50M 120 CS-UPS1 44 F20DKCG5B 61 R42T24 115
CK/S 129 CR4-1 103 CS-UPS2 44 F20DPCG5C 62 R81E24 97
CKB 129 CR4-2SC 104 CSW121B 28 F20TYS9 60 R81EAD 98
CKBG 129 CR8-1 103 CSW121C 28 F25TYT8 59 R81S24F 116
CKBX2 129 CR8-3 105 CSW241B 29 F300TDSS84C 58 R81U24F 99
CK-PCB 129 CRE4-1 103 CSW241C 29 F30DKCS5B 61 R82E24 100
CKR16 94 CRE4-2SC 104 CSW241DP 29 F30DPGS5C 62 R82EAD 101
CKR25 94 CRE8-1 103 CSW241G 29 F30TDVST2 55 R82S24 114
CKS024DC024DC03 110 CRE8-3 105 CSW481C 30 F36TYT8 59 R82T24 115
CKS024DC024DC05 110 CSA120BC 39 CSW481D 30 F400TDSS84C 58 RE1024D 86
CKS024DC024DC10 110 CSA120CB 39 CSW481G 30 F42TDVST2 55 RE1824D 86
CKS024DC230AC05 111 CSA120CC 39 CSW960CP 31 F50TYT8 59 RE2024D 87
CKS1S 113 CSA120DC 39 CWAA7-0530 70 F55TDVST2 55 RF1024D 86
CL1R 41 CSA240FC 40 CWAA7-0531 70 F75TDVST2 55 RF1824D 86
CL5R 41 CSBC 43 CWAA7-0532 70 IF10PML 120 RFA024D 86
CLP08CC 127 CSBD 48 CWAA7-0533 71 IF14PML 121 RMP081CM 102
CLP16CC 127 CSC120B 47 CWAA7-0534 71 IF16PML 121 SW50VA 81
CLT08AC 126 CSC120C 47 CWAA7-0535 71 IF20PML 121 WAA7-0540 80
CLT08CC 126 CSD15B 11 CWAA7-0536 72 IF26PML 121 WAA7-0541 80
CLT16AC 126 CSD15C 11 CWAA7-0537 72 IF34PML 121 WAA7-0542 80
CLT16CC 126 CSD30C 12 CWAA7-0538 72 IF40PML 121

135
Index by Catalogue number
CODE PAGE CODE PAGE CODE PAGE CODE PAGE CODE PAGE
PTCCK42 130 XCDM08CC 125 XCMB16B 131 XCSG481C 33 XF75TDVST2 55
X756340 75 XCDM08CS 124 XCMB27B 131 XCSG500C 34 XIF10PML 120
X756360 74 XCDM16AC 125 XCOP082 117 XCSG500G 34 XIF14PML 121
X756370 76 XCDM16CC 125 XCPC20M 122 XCSG720C 35 XIF16PML 121
X756516 68 XCDM16CS 124 XCPC26M 122 XCSG720D 35 XIF20PML 121
X756524 82 XCDM24AC 125 XCPC34M 122 XCSG960C 36 XIF26PML 121
X756526 73 XCDM24CC 125 XCPC40M 122 XCSG960D 36 XIF34PML 121
X756527 73 XCDM24CS 124 XCPC50M 122 XCSG960G 36 XIF40PML 121
X756530 70 XCEPBCB 53 XCPC60M 122 XCSL120C 24 XISD09FM 119
X756531 70 XCEPBCR 53 XCPC64M 122 XCSL240C 25 XISD09PF 119
X756532 70 XCEPD1 53 XCPD25F 120 XCSL481C 26 XISD09PM 119
X756533 71 XCEPD2 53 XCPD25M 120 XCSL85C 23 XISD15FM 119
X756534 71 XCEPMTW 53 XCPD37F 120 XCSR50U 49 XISD15PF 119
X756535 71 XCEPRCC 53 XCPD37M 120 XCSU0120S 45 XISD15PM 119
X756536 72 XCEPRCP 53 XCPD50F 120 XCSU240S 46 XISD25FM 119
X756537 72 XCEPSS 53 XCPD50M 120 XCSUPS1 44 XISD25PF 119
X756538 72 XCKB 129 XCR41 103 XCSUPS2 44 XISD25PM 119
X756539 69 XCKBG 129 XCR42SC 104 XCSW121B 28 XISD37FM 119
X756540 80 XCKPT 129 XCR81 103 XCSW121C 28 XISD37PF 119
X756541 80 XCKR16 94 XCR83 105 XCSW241B 29 XISD37PM 119
X756542 80 XCKR25 94 XCRE41 103 XCSW241C 29 XMBC2K 51
X756816 77 XCKS 129 XCRE42SC 104 XCSW241DP 29 XNPNPNP 84
X756844 78 XCKS024DC024DC03 110 XCRE81 103 XCSW241G 29 XO332060 107
X756894 74 XCKS024DC024DC05 110 XCRE83 105 XCSW481C 30 XO332240 107
X766082 113 XCKS024DC024DC10 110 XCSA120BC 39 XCSW481D 30 XR041E24 97
X766083 112 XCKS024DC230AC05 111 XCSA120CB 39 XCSW481G 30 XR041EAD 98
X766184 83 XCKS1S 113 XCSA120CC 39 XCSW960CP 31 XR041S24F 116
X766802 130 XCKX2 129 XCSA120DC 39 XF03DKBG5B 61 XR041U24F 99
X766803 130 XCL1R 41 XCSA240FC 40 XF03DPCG5C 62 XR042E24 100
X766804 130 XCL5R 41 XCSBC 43 XF06DKBG5B 61 XR042EAD 101
X766813 130 XCLP08CC 127 XCSBD 48 XF06DPCG5C 62 XR042S24 114
X766842 95 XCLP16CC 127 XCSC120B 47 XF07TDVST2 55 XR042T24 115
X766845 95 XCLT08AC 126 XCSC120C 47 XF100TDVST2 55 XR081E24 97
X766846 95 XCLT08CC 126 XCSD15B 11 XF100TYT8 59 XR081EAD 98
X766847 95 XCLT16AC 126 XCSD15C 11 XF10TYG9 60 XR081S24F 116
X766848 95 XCLT16CC 126 XCSD30C 12 XF12DKBG5B 61 XR081U24F 99
XAR6 42 XCM1A012 91 XCSD30E 12 XF12DPCG5C 62 XR082E24 100
XBB125 128 XCM1A024 91 XCSD30F 12 XF150TDS84C 56 XR082EAD 101
XBC000 128 XCM1A120 91 XCSD50B 13 XF16DKCG5B 61 XR082S24 114
XBC010 128 XCM1A230 91 XCSD70C 14 XF16DPCG5C 62 XR082T24 115
XBC225 128 XCM1C012 88 XCSF120C 18 XF16TDVST2 55 XR161E24 97
XBC325 128 XCM1C024 88 XCSF120CP 18 XF16TYT8 59 XR161EAD 98
XBCA00 128 XCM1C048 88 XCSF120DP 18 XF180TDS84C 56 XR161S24F 116
XBS000 128 XCM1C110 88 XCSF240C 19 XF200TDDS84C 57 XR161U24F 99
XCAPIPO3 67 XCM1S024 108 XCSF240CP 19 XF20DKCG5B 61 XR162E24 100
XCCIS2 79 XCM1S024E 108 XCSF240DP 19 XF20DPCG5C 62 XR162EAD 101
XCCM08CV 123 XCM1T024 109 XCSF30C 16 XF20TYS9 60 XR162S24 114
XCCM08SV 123 XCM1T024E 109 XCSF500C 20 XF25TYT8 59 XR162T24 115
XCCM16CV 123 XCM2A012 92 XCSF500D 20 XF300TDSS84C 58 XRE1024D 86
XCCM16SV 123 XCM2A024 92 XCSF565 21 XF30DKCS5B 61 XRE1824D 86
XCCM24SV 123 XCM2A120 92 XCSF85B 17 XF30DPGS5C 62 XRE2024D 87
XCDIN2 132 XCM2A230 92 XCSF85C 17 XF30TDVST2 55 XRF1024D 86
XCDIN4 132 XCM2C012 89 XCSF85CP 17 XF36TYT8 59 XRF1824D 86
XCDIN5 132 XCM2C024 89 XCSG2401C 37 XF400TDSS84C 58 XRFA024D 86
XCDINM45 132 XCM2C048 89 XCSG2401D 37 XF42TDVST2 55 XRMP081CM 102
XCDIWMP2 131 XCM2C110 89 XCSG2401G 38 XF50TYT8 59 XW000932 81
XCDM08AC 125 XCM4C024 90 XCSG2401R 38 XF55TDVST2 55

136
ELECTRONIC PRODUCTS PRODUCTS AND SYSTEMS PHOTOVOLTAIC SYSTEMS INDUSTRIAL MARKING
FOR ELECTRICAL PANELS FOR THE CONNECTION CONNECTION AND SYSTEMS
OF ELECTRICAL PANELS PROTECTION

D021G17A - 0717 - 2017/2018 EDITION

Cabur Srl Romanian Branch


17041 - Altare (SV) Cabur Romania Srl
Località Isola Grande, 45 - Italy Strada Calea Plevnei nr. 139
T. +39 019 58999.1 Corp B camera 25,26 sector 6
F. +39 019 58999280 Bucuresti
www.cabur.it T. +40 (21)31.17.140
[email protected] F. +40 (21)31.17.140
www.cabur.eu
[email protected]

You might also like