Electronic Products 2017
Electronic Products 2017
2
since 1952
The Company
F ounded in 1952, Cabur quickly gained the lead position among national manufacturers of terminal blocks for electrical panels, pursuing
a policy which focused particularly on installers' needs and offering cutting-edge technological solutions.
With over 65 years of experience, Cabur develops and creates, based on its own designs, a vast array of products for the electro-technical
and electronic industries famous for their reliability even under extreme conditions.
• terminal blocks and boards for electrical panels In pursuing a corporate culture based on Total Quality, Cabur has
• electronic products for electrical panels adopted the main European directives of the reference market,
• terminal blocks for civil and industrial installations and collaborates with the most prestigious national and foreign
• products for photovoltaic systems Institutes and Laboratories.
• industrial marking systems
ELECTRONIC PRODUCTS
FOR ELECTRICAL PANELS
PRODUCTS INDUSTRIAL
FOR INSTALLATION MARKING SYSTEMS
www.cabur.eu
3
Introduction
Cabur . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 3
Power supplies
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 6
Quick selection table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 8
CSD series Domotic Power single-phase modular switching . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 10
CSF series Cool Power single-phase switching . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 15
Single-phase switching in IP65 case . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 21
CSL series Easy Power single-phase switching . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 22
CSW series Universal Power single-, 2- and 3-phase switching . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 27
CSG series Triple Power 3-phase switching . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 32
CSA series DC/DC switching converters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 39
With 24 Vac transformer input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 41
DC battery charger-UPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 43
CSC series power supply with integrated battery charger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 47
Redundant connection accessory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 48
Engine braking control module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 50
EMI filters
Quick selection table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 54
TDV series 3-phase filter without neutral . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 55
TDS series 3-phase filter without neutral . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 56
TDDS series 3-phase filter without neutral . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 57
TDSS series 3-phase filter without neutral . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 58
TYT series 3-phase filter with neutral . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 59
TY series compact 3-phase filter with neutral . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 60
DK series single-cell single-phase filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 61
DP series double-cell single-phase filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 62
Signal conditioners
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 63
Quick selection table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 65
Analogue signal converters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 67
Passive galvanic isolators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 73
Monitor module for alanogue signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 74
Universal temperature converters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 75
Monitor module for temperature sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 76
Programmable PT100 converters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 77
Programmable TC J and K converters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 78
Monitor module for current signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 79
Current / analogue signal converters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 80
Frequency / analogue signal converters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 82
Auxiliary power supply for sensors and potentiometers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 83
NPN and PNP signal inverter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 84
4
Electromechanical relay modules
Single relay quick selection table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 85
R series relay modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 86
CM series relay modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 88
CKR series relay modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 93
CWRE series relay modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 95
Multiple relay quick selection table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 96
Multiple relay module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 97
Multiple relay module with test button . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 102
CR and CRE series super compact relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 103
Accessories
Electronic circuit housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 128
Bridges and markings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 130
DIN rail clamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 132
Mounting rails . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 133
5
C abur continues to renew and expand its range of power supplies for use in
industrial automation and control of processes and systems, improving product
performance and technology to meet the needs created by the continuing changes
load, which can go from a few tenths of a ms up to 5s.
With high-power power supplies, which power various loads protected from
overcurrent, the capacity to provide overcurrent is indispensable to guarantee
in applications and regulations. selectivity in protection interventions. This is because it allows the fuse of the
malfunctioning load to be “burned” before the electronic protection of the power
QUALITY AND SAFETY: Cabur was the first Italian company to obtain UL508 supply intervenes, disconnecting the output and hence the entire system.
Industrial Control Equipment certification for industrial automation processes and
Hazardous Location Class 1 Div. 2 for processes in dangerous areas, as well as to ELECTRONIC OVERLOAD POWER SUPPLY PROTECTION CAN BE OBTAINED
have been certified as conforming to the Directives on Electric Safety. It also has USING VARIOUS TECHNIQUES:
been EMC certified by an accredited laboratory. All of these are indispensable for – switch off the output as soon as possible: this is cost effective but doesn’t allow
the CE certified label. for either start up of heavy loads nor for protection selectivity for various loads.
– constant power protection: if the allowed overload is sufficiently high, it is possible
INNOVATION AND RESEARCH: to start up heavy loads. However, if the condition continues, the power supply
• 1997 - Cabur is the first Italian company to produce switching power supplies for will continue to operate in overload and with a high thermal stress level. Hiccup
DIN-rails with 90-264Vac/110-340Vdc universal input. protection: combines the advantages of the techniques described above, while
• 2001 - Cabur is the first Italian company to produce high efficiency power supplies limiting the disadvantages because it allows over +50-100% of the overload for at
with resonant technology (the 20A 3-phase dissipates only 36W compared to over least 5 seconds, and then switches off output for a longer break. In this way, the
75W for our competitors at the time). peak power necessary for heavy load peaks is obtained while component heating
• 2009 – With the new generation of power supplies in the catalogue, Cabur is decreased, as they can cool off during the break. Hiccup protection with high
has further improved performance using “Synchronous Rectifier" technology, overcurrent output, for durations from 200 ms to over 5 sec., has been proven to
which reduces power dissipation and operating temperature to the minimum, an satisfy the new requirements established by the Machinery Directive EN 60204-1.
indispensible factor in minimising the size of the power supplies, which are the
smallest on the market. REAL OPERATING TEMPERATURE: the operating temperature range for all Cabur
The lifespan of a power supply is halved by every +10°C increase in operating models is between –20 and +50°C at full load without derating (see technical data),
temperature. Hence, reducing operating temperature is fundamental to endurance certified in accordance with the rigorous UL508 standard.
and reliability, two objectives that can be achieved only by using circuit technology The project takes into consideration the ambient temperature, allowed overcurrent,
and next generation components. Thanks to this combination, Cabur has achieved and overcurrent duration when determining component size, and is always more than
output of over 94% (the new 20A 3-phase dissipates only 28W, compared to the the 45°C required by the standards for electrical panels. Ambient temperature is a
50-75W in heat dissipation found in other products currently on the market). fundamental reference parameter, because this influences not only performance, but
also component operating temperature and power supply duration.
HIGH OVERLOAD CAPACITY: the new power supplies have an overload capacity of
over +50% for 5 seconds or for several minutes (please see the technical data), while HOLD UP TIME: this is the time in which the power supply output supplies nominal
maintaining stable output voltage even under these conditions. voltage at nominal load. This performance is important because it limits the cases in
which machine/system stoppage can occur due to voltage "holes" in the network.
SYSTEM COMMUNICATIONS: all the CSF, CSG, and CSW Series models are EMC standards establish that Hold Up time must be at least 10ms. For all Cabur
provided with “intelligent” alarm contacts that commutate when the output voltage power supplies, Hold Up time is greater than that required by the official standards,
drops below -10% of the nominal value. This allows the controls to activate which ensures better operational consistency in networks with frequent voltage holes.
automated or emergency procedures to reduce machine stoppage, production
losses, and the risk to safety. MTBF: this figure should be taken with care, because it is the result of theoretical
calculations that are easy to manipulate. For example, if we know that the mortality
TOTAL PROTECTION: all models are provided with output protection against overload rate for 25 year old men is 0.1%/year, the resultant MTBF, calculated in accordance
short circuiting, overtemperature, and overvoltage, both for input and output. Input for with SN29500 – IEC 61709, would be 800 years. Obviously, this result is highly
the 3-phase models includes the Active Surge Suppressor – Inrush Current Limiter, unrealistic. The significant piece of information is the “life expectancy,” which for men
which avoids malfunctioning in the case of overvoltage generated by commutation of averages about 75 years – less spectacular but more realistic. The same reasoning
loads or malfunctions on industrial networks, where the value can reach 3-4 times can be applied to electronic products for which, in accordance with the calculation
the network voltage, with a duration of 1.3ms (Regulation VDE-0160), which can be methods, we can use an MTBF of 750,000 hours (85 years), or a life expectancy of
destructive for the input components. This increases reliability, especially in networks about 70,000 hours (7.9 years, on average). The second estimate is less optimistic,
subject to power surges and power malfunctions. but is without doubt closer to reality. As a consequence, data published regarding
MTBF must be interpreted based on the credibility of the calculation methods used.
SHORT CIRCUIT AND OVERLOAD PROTECTION: this serves to protect the power In addition to the values according to SN 29500, Cabur has also chosen to declare
supply from malfunctions due to overloading and overheating of the components. those according to the MIL HDBKn217F standards, which are much stricter.
This function can be designed by starting with different application needs, with
varying practical results and costs. In automated applications, the operating CUSTOM POWER SUPPLIES: Cabur designs and produces “custom” power supplies
conditions and the nature of the loads can vary greatly and are only partially known to on request to meet the requirements of regulations and the high demanding
the power supply designer. Power supplies for automated processes need to meet a applications. Furthermore our laboratory offers technical documentation and the
number of requirements: they need to be protected from overcurrent, but at the same measures which prove the conformity of the products with the directives on Electric
time they need to be able to supply loads which call for a high peak current, working Safety and Electromagnetic Compatibility, besides the necessary technical support
at temperatures of at least 45° C, according to regulations, and sometimes higher, in to define the product characteristics on the basis of the client’s needs and our own
critical ventilation situations and guaranteeing high reliability and acceptable costs. experience.
The overcurrent protection must support the high peak currents required by
loads such as filament lamps (cold, they make a short circuit), capacitive loads THE ENVIRONMENT AND ROHS CONFORMANCE:
such as dc/dc converters and filter condensators (when these switch on they are Cabur was one of the first Italian companies to obtain the International Environmental
seen as a short-circuit for a few tenths of a ms) or inductive loads (engines in Certificate UNI EN ISO 14001, certified by CSQ for ecologically compatible treatment
dc, electromagnets, etc.) which at peak require currents from 5 – 30 times their of all the materials used in our production.
nominal power. Frequently, all these loads must be started up at the same time. The Since 2007, all Cabur products have been manufactured in conformity with the Rohs
breakaway starting current must be provided for a sufficient duration to “start” the Wee directives.
6
L AC + +
General notes GND
CONNECTION IN SERIES: all Cabur power supplies can have their outputs connected
in series to double the voltage (see fig. 2) or to obtain dual voltage output, for example L AC + +
with ± 12V or ±24 V (see fig. 3). GND V
We recommend that you use power supplies of the same model and an anti-parallel
diode, of an appropriate size to resist the maximum current of the power supply. N AC –
V+V
POWER SIGNAL OK: this is found on all CSF, CSG, and CWS models. The 1A / 30Vdc AC +
contact commutates when output voltage falls below the threshold of -10% of nominal
voltage, in the case of a short circuit on the output line or an overload that exceeds the GND V
specifications, or due to network failure. Figure 2
AC – –
100-340Vdc POWER SUPPLY: available for certain models (please see technical data),
which respect the following:
– power supply of 110…127 Vdc, reduces output current by 25%
– min. voltage allowed 100 Vdc, max 340 for single phase, 280…775 Vdc for single/2-
phase, 564… 775Vdc for 3-phase (please see technical data) L AC + +
– respect input polarity as indicated in the instructions.
GND V
+V
N AC –
Note for power supplies with secondary input from a 0
transformer
AC +
-V
ISOLATION: this series of power supply units is not insulated. GND V
TYPE OF USE: they are suitable for use in PELV (Protective Extra Low Voltage, one pole
grounded) and SELV (Safety Extra Low Voltage, no pole grounded). AC – – Figure 3
The transformer used must have double or reinforced isolation in accordance with CEI
14.6 / EN 60742.
In the case of use in PELV circuits, only ground one pole of the 24 Vdc of the power
supply unit. In the case of use in SELV circuits, do not ground the input grounding
terminal.
24 Vdc
Grounding one pole of the secondary of the transformer and the 24Vdc of the load
power supply would damage the power supply.
24 Vac / 24 Vdc not insulated
power supply
24 Vdc
load
Figure 4
Figure 5
7
These tables are used for quickly identifying items and verifying whether all of the product’s technical details satisfy the set requirements.
8
These tables are used for quickly identifying items and verifying whether all of the product’s technical details satisfy the set requirements.
(All wide range single-phase power supplies may be powered at 110 Vdc)
9
Modular switching power supply - CSD Series
DOMOTIC POWER
Single-phase switching power supply with power up to 70W for use in civil and industrial
automation applications. The technical and design characteristics of the housing, with standard
modular DIN measurements for installation in control units were planned to optimise use in home
automation. The performance level and compact size also make it an excellent solution for electrical
panels and shallow containers.
High output and a contained working temperature support energy savings and longer component life.
Suggested uses
• Industrial automation applications
• Civil automation applications
• General applications in systems installed using small remote panels
Main features
• The 90…264 Vac and 110…370 Vdc inputs, make it suitable for use on all power supply networks.
• These are Isolation Class 2 power supplies that do not require a grounding connection, which
reduces the times and costs of installation in remote panels and surveillance and monitoring
systems.
• Their high efficiency reduces energy consumption and operating temperature and allows for use in
small housings.
• The large power reserve allows continuous current to be supplied up to at least +50% higher than
the rated value, ensuring safety and reliability.
• Short-circuit and overload protection designed to deliver peak currents more than 150% higher than
the rated value required by heavy loads.
• Thermal protection prevents failure in cases of prolonged overload at high ambient temperatures.
• Thanks to the high performance and excellent ventilation of internal the components, they are
greatly reduced in size and have a degree of protection from accidental contacts of IP20 per IEC529.
High efficiency
Designed to save energy and
Power boost reduce operating temperature
The output power
supplied reaches up to
130% of the rated value.
10
Single-phase switching
power supply 120-230
Vac - output power 15 W
• Single-phase input 90…264 Vac and DC 100…315 Vdc 90
• Short circuit, overload, over temperature, input overvoltage
protection
• Isolation Class 2, does not require grounding connection
• Compact dimensions
62
• Suitable for SELV and PELV circuits
35
E203601
11
Single-phase switching
power supply 120-230
Vac - output power 30 W
• Single-phase input 90…264 Vac and DC 100…345 Vdc 90 90
• Short circuit, overload, over temperature, input overvoltage
protection
• Isolation Class 2, does not require grounding connection
• Compact dimensions
• Suitable for SELV and PELV circuits 62 62
71 71
E203601
the line resistance.
12
Single-phase switching
power supply 120-230
Vac - output power 50 W
• Single-phase input 90…264 Vac and DC 100…345 Vdc
90
• Short circuit, overload, over temperature, input overvoltage
protection
• Isolation Class 2, does not require grounding connection
• Compact dimensions
• Suitable for SELV and PELV circuits 62
71
E203601
13
Single-phase switching
power supply 120-230
Vac - output power 70 W
• Single-phase input 90…264 Vac and DC 100…345 Vdc 90
• Short circuit, overload, over temperature, input overvoltage
protection
• Isolation Class 2, does not require grounding connection
• Compact dimensions
• Suitable for SELV and PELV circuits 62
71
E203601
14
COOL POWER
Single-phase switching power supply with DIN-rail, designed specifically for applications in
command and control panels for industrial automation and process control. Capable of delivering +60% Special power supplies for engines DC,
to +80% nominal current for a prolonged period of time while maintaining a constant output voltage and Brushless, and relative drives
equipped with a voltage threshold-controlled failure contact which is triggered when the voltage drops
below 90% of the rated value. With these features and numerous international certifications, New 48Vdc and 72-85Vdc models have been
this range of power supplies enables designers to meet the requirements of the Machinery introduced, designed to reliably power engines
Directive EN 60204-1, allowing the protection devices connected to the output to trigger quickly, safely in DC. They:
• supply peak power equal to even 4-5 times
and selectively, thus ensuring continuity of service to the other parts of the system. the nominal current, which is required by the
engine during the peak phase
Suggested uses • have an output stage protected from
• Applications in industrial automation with high performance and reliability requirements. overvoltage generated by the engines and
• Applications which require selectable overcurrent protections on DC lines drives during braking, which could otherwise
• Applications in machine automation with high command and control voltage reliability and safety cause malfunctions or cause the power supply
requirements to lose control over output voltage stability
• Provide output voltage at 48Vdc, and
• Applications in process control 72…85Vdc. By increasing the voltage of
• Uses with heavy loads the engine power supply, the same power
• Civil automation applications can be obtained at lower current, with
notable advantages for performance, engine
Main features construction, connection wires, and drives.
• The 90…264 Vac and 110…370 Vdc inputs, make it suitable for use on all power supply networks.
• Threshold failure contact which is triggered when the voltage falls below 90% of the rated value.
• Versions with integrated ORing diode for redundant parallel connection, preventing the need for
external devices and reducing bulk and installation costs.
• High efficiency reduces energy consumption and the operating temperature of components and
allows use in small panels and severe environmental conditions.
• Large power reserve allows for delivery of at least +60-80% nominal current and voltage for several
minutes, ensuring safety and reliability.
• Output voltage is adjustable and the output is protected against input surge from the DC line
generated from inductive loads.
• The output is equipped with dual electronic protection which prevents dangerous voltages for
powered components in the event of an internal fault.
• Thermal protection prevents faults in case of prolonged overload with high ambient temperatures.
• Construction ensures excellent ventilation capacity of internal components, with reduced sizes and
a degree of protection from accidental contacts of IP20 per IEC529.
• Thanks to their high performance and excellent ventilation capacity, they are among the smallest on
the market.
Extremely compact dimensions
Among the smallest on the market, Short-circuit and overload protection
optimising the use of space in the panel
without compromising performance Designed to deliver
the strong peak currents
required by heavy loads
Power boost
The output power
reaches 120% of
the nominal value
for several minutes,
up to 160% in the
event of overload, and
up to 300% during
a short-circuit, to
enable the protection
devices connected to
the output to trigger
High efficiency
quickly, safely and
selectively, without Designed to save
the use of additional energy and reduce
modules. operating temperature
power and Ta> 45°C, the outrush current is reduced by 25%
(3) O ver 50°C apply the following derating: version C:
-0.03 A/°C; version B: -0.038 A/°C; version F: -0.013 A/°C
(4) The value of the current supplied by the power supply also
depends on the line resistance.
16
Single-phase switching
power supply 120-230
Vac - output power 85 W
115
• Single-phase input 90…264 Vac and DC 100…345 Vdc
• Short circuit, overload, over temperature and overvoltage
input and output protection
• Elevated outrush current to ensure the selectivity of
protections and start-up of heavy loads
• Failure contact with threshold Uout -10% 128
• Compact dimensions
• Suitable for SELV and PELV circuits E212719
E203601
39
17
Single-phase switching
power supply 120-230
Vac - output power 120 W
115
• Single-phase input 90…264 Vac and DC 100…345 Vdc
• Short circuit, overload, over temperature and overvoltage
input and output protection
• Elevated outrush current to ensure the selectivity of
protections and start-up of heavy loads
• Failure contact with threshold Uout -10% 128
• Compact dimensions
• Suitable for SELV and PELV circuits E212719
E203601
39
18
Single-phase switching
power supply 120-230
Vac - output power 240 W
140
• Single-phase input 120 and 230 Vac
• Short circuit, overload, over temperature and overvoltage
input and output protection
• Elevated outrush current to ensure the selectivity of
protections and start-up of heavy loads
• Failure contact with threshold Uout -10% 135
• Compact dimensions
• Suitable for SELV and PELV circuits E212719
E203601
63.5
(3) Over 45°C apply the following derating: -0.17 A/°C for version C,
CP and CPH; -0.27 A/°C for version B; -0.08 A/°C for version DP;
(4) For this peak of power, the output voltage does not decrease more
than 10% of the rated value, however the value of the current
supplied by the power supply also depends on the line resistance.
19
Single-phase switching
power supply 120-230
Vac - output power 500 W
• Single-phase input 120 and 230 Vac 127
• Short circuit, overload, over temperature and overvoltage
input and output protection
• Elevated outrush current to ensure the selectivity of
protections and start-up of heavy loads
• Compact dimensions
• Suitable for SELV and PELV circuits 139
• Failure contact with threshold Uout -10% E212719
E203601
80
+
-0.34 A/°C for version C; -0.17 A/°C for version D.
FILTER
PE +
+
(4) For this peak of power, the output voltage does not decrease
N AC
more than 10% of the rated value, however the value of the
current supplied by the power supply also depends on the
line resistance.
PWM
20
Single-phase switching
power supply 120-230
Vac in IP65 case
• Single-phase input 90…264 Vac and DC 100…345 Vdc
• Short circuit, overload, over temperature and overvoltage 120
input and output protection
• Suitable for installation directly on-board the machine,
requiring no protective coating
• With removable screw-fixed IP65 connector
• Suitable for SELV and PELV circuits 190 80
E203601
21
Switching power supply - CSL Series
EASY POWER
Single-phase switching power supply for DIN-rail, for general applications in automation and
installation. Offering excellent value for money, these offer a perfect and convenient solution for uses in
which the powered loads do not require strong peak currents.
They can deliver over +50% of nominal current for a sustained period, keeping the output voltage stable
and ensuring continuity of supply to the system. With these features, this range of power supplies
enables designers to meet the requirements of the Machinery Directive EN 60204-1, allowing
the protection devices connected to the output to trigger quickly, safely and selectively, thus ensuring
continuity of service to the other parts of the system.
Suggested uses
• Civil automation applications
• General applications in plant installations
Main features
• Equipped with a 120-230 Vac input, these are suitable for use in all single-phase networks
• High efficiency reduces energy consumption and the operating temperature of components and
allows use in small panels and severe environmental conditions.
• Power reserve +50% of nominal current, ensuring safety and reliability.
• Output voltage is adjustable and protected against incoming surge generated by inductive loads on
the DC line, and is equipped with a double electronic protection that prevents the powered device
from failing in case of an internal malfunction.
• Short-circuit, overload and thermal protection prevents faults in case of prolonged overload with
high ambient temperatures.
• Construction ensures optimal capacity of ventilation of internal components, extremely reduced
overall dimensions and degree of protection IP20 by accidental contact according to IEC529.
• Offer superior performance, features and reliability compared to other products of a similar power
and cost.
22
Single-phase switching
power supply 120-230
Vac - output power 85 W
• Single-phase input 90…264 Vac 115
• Short circuit, overload, over temperature and overvoltage
input and output protection
• Ideal for general installation and application
environments
• Suitable for SELV and PELV circuits 128
E203601
39
current supplied by the power supply also depends on the
line resistance.
23
Single-phase switching
power supply 120-230
Vac - output power 120 W
• Single-phase input 90…264 Vac 115
• Short circuit, overload, over temperature and overvoltage
input and output protection
• Ideal for general installation and application
environments
• Suitable for SELV and PELV circuits 128
E203601 39
line resistance.
24
Single-phase switching
power supply 120-230
Vac - output power 240 W
• Single-phase input 120 and 230 Vac 140
• Short circuit, overload, over temperature and overvoltage
input and output protection
• Ideal for general installation and application
environments
• Suitable for SELV and PELV circuits
135
E203601
63.5
+
(3) Over 45°C apply a derating equal to -0.17 A/°C PE FILTER +
+
(4) For this peak of power, the output voltage does not decrease
N AC
more than 10% of the rated value, however the value of the
current supplied by the power supply also depends on the
line resistance.
PWM
(5) Version available since September 2011
120 Vac selection terminals
25
Single-phase switching
power supply 230 Vac -
output power 480 W
• Single-phase input 230 Vac
140
• Short circuit, overload, over temperature and overvoltage
input and output protection
• Ideal for general installation and application
environments
• Suitable for SELV and PELV circuits
137
E203601 73
26
UNIVERSAL POWER
DIN-rail based switching power supply with universal input 185…550 Vac single/2 /3-phase for
industrial automation and process control applications. Input circuit technology makes these immune to
Greater reliability
overvoltage caused by faults in 3-phase networks with neutral, increasing the reliability of application.
This series offers greater reliability in industrial
This series offers greater reliability in industrial environments compared to single-phase power supplies. environments compared to single-phase power
The input stage uses components with an operating voltage of 900 V, offering greater resistance to the supplies.
voltage peaks present in industrial networks than single-phase components. The ability to operate from 185 The input stage uses components with an
to 550 Vac allows these power supplies to be used in both 230 V single-phase networks and 400 V 3-phase operating voltage of 900 V, offering greater
networks. resistance to the voltage peaks present in
industrial networks than single-phase
components.
Suggested uses The ability to operate from 185 to 550 Vac
• Wherever maximum flexibility of use is required in single- or 3-phase networks makes these power supplies immune to network
• Applications in industrial automation and process control faults:
• Uses with heavy loads With the output powered at 230 Vac (1L-N), in
case of a short in another device connected to
• Civil automation applications L2-N, the neutral is increased to around 400
Vac and the input is powered phase-phase
Main features until the protection is opened, which in most
• The 185…550 Vac extended range input is compatible with 230…240 Vac single-phase power, 208 cases occurs within 300 ms; this is one of the
Vac 2-phase and 400…500 Vac 2-phase and 3-phase for maximum adaptability to AC networks, most frequent causes of malfunction in 230
eliminating the need for an isolation transformer. Vac single-phase power supplies in industrial
environments (figures 1 and 2)
• The 2-phase input offers reduced bulk, wiring, installation costs and panel space. Another type of fault in 230 Vac single-phase
• Eliminates the need for a network voltage adaptation transformer. devices with phase-neutral power is due to the
• Versions with DC OK failure contact accidental disconnection or interruption of the
• High efficiency reduces energy consumption and the operating temperature of components and allows panel neutral by the plant neutral: with no return
to the star point, the neutral increases to phase
use in small panels and severe environmental conditions. voltage and applies to single-phase loads of
• Large power reserve allows 5 seconds of current to be supplied at least +50% higher than the rated around 400 Vac, and malfunction is inevitable.
value, ensuring safety and reliability.
• The output is adjustable and protected against incoming surge from the DC line, and is equipped with
electronic protection that turns off the output in case of an internal malfunction.
• Short-circuit and overload protection designed to supply peak currents of more than 150% of the rated
value required by heavy loads, while the thermal protection prevents faults in case of prolonged overload
with high ambient temperatures.
• Construction ensures excellent ventilation capacity of internal components, with reduced sizes and a
degree of protection from accidental contacts of IP20 per IEC529.
• Thanks to their high performance and excellent ventilation, they are among the smallest on the market.
High performance
Reduces the energy
consumption and operating
temperature of components
and allows for use in small
panels A single short-circuit on the load will raise the
neutral potential and all devices connected to
it will be powered between two phases, i.e. at
Increased reliability in industrial environments around 340...400 Vac rather than 230 Vac.
The input stage uses components with an operating voltage of 900 V,
more resistant to the voltage peaks found in industrial networks
27
1 or 2-phase switching power
supply 230-400-500
Vac - output power 120 W
• Single-phase and 2-phase input 185...550 Vac 115
• High reliability and surge immunity for network failures
• Short circuit, overload, over temperature and overvoltage input and
output protection
• Elevated outrush current to ensure the selectivity of protections and
start-up of heavy loads
130
• High efficiency and low consumption
• Suitable for SELV and PELV circuits E203601 39
clearance.
(1) Version made to order (not kept in stock); contact our sales
office for availability.
28
1, 2 or 3-phase switching power
supply 230-400-500 Vac - output
power 240 W
• Single-phase, 2-phase and 3-phase input 185…550 Vac 115
• High reliability and surge immunity for network failures
• Short circuit, overload, over temperature and overvoltage input and
output protection
• Elevated outrush current to ensure the selectivity of protections and
start-up of heavy loads
130
• High efficiency and low consumption
• Suitable for SELV and PELV circuits E203601
55
office for availability.
(2) 550 Vdc max for UL508
(3) Over 50°C apply a derating equal to approximately 3 W/°C
(4) For this peak of power, the output voltage does not decrease
more than 10% of the rated value, however the value of the
current supplied by the power supply also depends on the
line resistance.
(5) Version CSW241G not suitable for SELV applications.
29
1, 2 or 3-phase switching power
supply 230-400-500 Vac - output
power 480 W
• Single-phase, 2-phase and 3-phase input 185…550 Vac 140
• High reliability and surge immunity for network failures
• Short circuit, overload, over temperature and overvoltage input and
output protection
• Elevated outrush current to ensure the selectivity of protections and
start-up of heavy loads
137
• High efficiency and low consumption
• Suitable for SELV and PELV circuits E203601 73
30
Single-/two-phase switching power
supplies 230-400-500
Vac - output power 960 W
• Single-phase, two-phase and three-phase input 185…480 Vac 127
• High reliability and surge immunity for network failures
• Short circuit, overload, overtemperature and surge input and output
protection
• Elevated outrush current to ensure the selectivity of protections and
start-up of heavy loads
139
• High efficiency and low consumption
• Suitable for SELV and PELV circuits 80
31
Switching power supply - CSG Series
TRIPLE POWER
400…500 Vac 3-phase switching power supply for industrial automation applications. They can
deliver over +50% of nominal current for a sustained period, keeping the output voltage stable and Special power supplies for engines
ensuring continuity of supply to the system. Equipped with voltage threshold controlled failure contact DC, Brushless, and relative drives
which is triggered when the voltage falls below 90% of the rated value.
With these features and numerous international certifications, this range of power supplies
New 48Vdc, 72-85Vdc, and 110-180Vdc
enables designers to meet the requirements of the Machinery Directive EN 60204-1, allowing
models have been introduced, designed to
the protection devices connected to the output to trigger quickly, safely and selectively, thus ensuring
reliably power engines in DC. They:
continuity of service to the other parts of the system.
• supply peak power equal to even 4-5 times
the nominal current, which is required by
Suggested uses
the engine during the peak phase
• Applications in machine automation with high command and control voltage reliability and safety
• have an output stage protected from
requirements
overvoltage generated by the engines
• In applications which require selectable overcurrent protections on DC lines
and drives during braking, which could
• Industrial automation applications
otherwise cause malfunctions or cause the
• Uses with heavy loads
power supply to lose control over output
voltage stability
Main features
• Provide output voltage at 48Vdc, and
• With 340…550 Vac/507…770 Vdc input, making them suitable for use on all power supply
72…85Vdc. By increasing the voltage
networks.
of the engine power supply, the same
• High efficiency reduces energy consumption and the operating temperature of components and
power can be obtained at lower current,
allows use in small panels and severe environmental conditions.
with notable advantages for performance,
• Large power reserve allows for delivery of at least +50% of nominal current for 5 seconds
engine construction, connection wires, and
maintaining the output voltage stable, ensuring safety and reliability.
drives.
• Output voltage is adjustable and protected against incoming surge from the DC line, and is equipped
with a double electronic protection that prevents damage to the powered device in case of an
internal malfunction.
• Short-circuit and overload protection designed to deliver peak currents more than 150% higher than
the rated value required by heavy loads.
• Thermal protection prevents faults in case of prolonged overload with high ambient temperatures.
• Construction ensures optimal capacity of ventilation of internal components, extremely reduced
overall dimensions and degree of protection IP20 by accidental contact according to IEC529.
Power boost
The output power Very high
reaches 120% of efficiency
the nominal value Designed to
for several minutes, save energy and
up to 150% in the reduce operating
event of overload, temperature
and up to 250%
during a short-
circuit, to enable the
protection devices
connected to the
output to trigger
quickly, safely and
selectively, without
the use of additional
modules. Wide range
The widest range on the market, with power ratings
from 120 to 2400W and output voltages of 24, 48 and
72 V, for uses including powering special motors
32
3-phase switching power
supply 400-500 Vac - output
power 480 W
• 3-phase 340...550 Vac or 2-phase with derating 140
• Short circuit, overload, over temperature and overvoltage input
and output protection
• Elevated outrush current to ensure the selectivity of protections
and start-up of heavy loads
• High efficiency and low consumption
137
• Suitable for SELV and PELV circuits
E203601 73
33
3-phase switching power
supply 400-500 Vac - output
power 500 W 127
• 3-phase 340...550 Vac or 2-phase with derating
• Short circuit, overload, over temperature and overvoltage input
and output protection
• Elevated outrush current to ensure the selectivity of protections 139
and start-up of heavy loads 80
• High efficiency and low consumption
• Suitable for SELV and PELV circuits
E203601
current supplied by the power supply also depends on the
line resistance.
34
3-phase switching power
supply 400-500 Vac - output
power 720 W 127
• 3-phase 340...550 Vac or 2-phase with derating
• Short circuit, overload, over temperature and overvoltage input
and output protection
• Elevated outrush current to ensure the selectivity of protections 139
and start-up of heavy loads 80
• High efficiency and low consumption
• Suitable for SELV and PELV circuits
E203601
more than 10% of the rated value, however the value of the
current supplied by the power supply also depends on the
line resistance.
35
3-phase switching power
supply 400-500 Vac - output
power 960 W 127
(4) For this peak of power, the output voltage does not decrease
more than 10% of the rated value, however the value of the
current supplied by the power supply also depends on the
line resistance.
(5) CSG960G version not suitable for SELV applications
36
3-phase switching power
supply 400-500 Vac - output
power 2400 W 130
• 3-phase input 340…550 Vac
• Short circuit, overload, over temperature and overvoltage input
and output protection
• Elevated outrush current to ensure the selectivity of protections
and start-up of heavy loads 234 105
• High efficiency and low consumption
• Suitable for SELV and PELV circuits
E203601
(4) For this peak of power, the output voltage does not decrease
more than 10% of the rated value, however the value of the
current supplied by the power supply also depends on the
37
3-phase switching power
supply 400-500 Vac - output
power 2400 W 130
• 3-phase input 340…550 Vac
• Short circuit, overload, over temperature and overvoltage input
and output protection
• Elevated outrush current to ensure the selectivity of protections
and start-up of heavy loads 234 105
• High efficiency and low consumption
• Suitable for PELV circuits
E203601
current supplied by the power supply also depends on the
38
DC/DC Insulated converters
output power 120 W
• D C wide range input
115
• S hort-circuit, overload, overtemperature protection
• E xtremely small size
128
39
39
DC/DC Insulated converters
output power 240 W
• D C wide range input
140
• S hort-circuit, overload, overtemperature protection
• Internal diode for the redundant parallel connection NOTE:
• E xtremely small size CSD, CSF30, CSF85 and CSF120 series power supplies
can also be powered at 110 Vdc.
135
63.5
40
Adjustable stabilised linear
power supply 24 Vac
• 1 .2...24 Vdc adjustable output voltage
• 1 .5 and 5 A output current 130 118
• S hort-circuit, overload, overtemperature protection
43 37
74 115
41
Filtered power supply
without transformer
and with non-stabilised output
93
• R ail mounting
• F or correcting voltages from 6 Vac to 20 Vac
•O utput 1.41 times the input voltage
70
80
42
Accessory for charging
buffer batteries
• B attery charging
• P arallel connection of power supplies 93
• S uitable for power supplies up to 10 A
• L ine and battery safety fuses
• F lyback diode
• L oad current limiting resistor 26
80
L AC + + + L AC + + +
GND (A) – + (A) – +
(C)
CSBC GND (C)
CSBC
+ – + –
N AC – – – N AC – – –
IN OUT IN OUT
+ AC +
(B)
BATTERY GND (A)
–
AC –
(A) Power supply
(C) CSBC
43
Accessory for charging
and checking buffer batteries
• S uitable for power supplies with adjustable output
115
• S uitable for lead batteries
• S upplies power to load and battery simultaneously
• B attery safety fuse Item available until supplies last; will be
• B attery full discharge protection 130 replaced by XCSU240S
• L ED status indicator and alarm relay 55
44
Accessory for charging
and checking buffer
batteries
88
• Power supply connection, supplies energy to the load and maintains
the backup battery
• Suitable for Lead-Acid, NiMH and Ni-Cd batteries
• 12 V or 24 V battery voltages with a load current of up to 5 A
• High efficiency and low consumption 63
• Small size 70
45
Accessory for charging
and checking buffer
batteries
115
• Power supply connection, supplies energy to the load and maintains
the backup battery
• Suitable for Lead-Acid, NiMH and Ni-Cd batteries
• 12 V or 24 V battery voltages with a load current of up to 10 A
• High efficiency and low consumption
130
• Small size
40
46
Switching power supply with
integrated battery charging
• For powering loads and maintaining battery charge
• Suitable for lead batteries 115
• Supplies power to load and battery simultaneously
• Battery safety circuit
• Battery full discharge protection
• LED status indicator and alarm relay
130
40
DC PSU OK
47
Accessory for redundant
power supply connections
• Suitable for connecting non-supplied power supplies
• Compact dimensions 130
• 12, 24 and 48 Vdc selectable operating voltages
• 2 alarm relays
• LED power indicator
43
85
Connection Diagram
48
Accessory for redundant
power supply connections
• Suitable for connecting power supplies without ORing diodes 110
• 12 to 85 V load voltages with currents of up to 50 A
• CPU-controlled electronic redundancy
• Current failure and unbalance alarm
• High efficiency and low consumption
• Compact dimensions 145
40
Bar-graph
System
power supply Microprocessor LEDs
OR_OK
Relays
SHARE_OK
49
MBC2K
DC bus-powered engine braking device
MBC2K setup
The MBC2K unit must be set-up prior to operation.
The menu comprises three pages, navigable using the MENU button;
The values shown can be adjusted by pressing the SET/RESET button.
a) brake intervention threshold (VTH)
b) brake intervention threshold hysteresis
c) Master/Slave mode; for selecting single mode (Master mode) or for parallel connection of up
to 4 cards (1 Master+3 Slave).
Active protections
The MBC2K integrates active protections to ensure stable and reliable operation under normal
use conditions. When it detects a fault, MBC2K turns itself off to prevent an uncontrolled flow of
current through the braking resistor.
Fault status is indicated by the alarm LED flashing continuously.
And the integrated alarm relay allows the status of the module to be checked remotely.
To help the user understand which defect has occurred, an error code is shown on the 7-segment Figure 1 application block diagram
display.
MBC2K unit configured as a Master and the other MBC2K units (up to 3) configured as Slaves.
The Master measures the DC bus voltage and decides when to insert the braking resistors into
the circuit, sending a command on the synchronisation bus. When the Slave units connected
MBC2K
to the synchronisation bus receive the command from the Master unit, they insert their braking
resistor into the circuit. When MBC2K is configured in Slave mode, all of its protective circuits R BRAKE
R Brake
<2kW
1. SET / RESET: Used to reset any errors and to change configurations in set-up mode.
2. MENU: Used to enter set-up mode and to navigate through the menu pages.
3. Synchronisation bus connector: used to connect up to 4 units in parallel.
4. Braking resistor thermostat connector: used to connect a thermostat present on the braking
resistor (Klixson normally closed type is recommended; if not used, short-circuit the 2 terminals).
5. Remote alarm connector: an SPDT contact triggers the fault/malfunction signal.
6. Braking resistor connector: used to connect the external braking resistor.
7. DC bus connector: used to connect MBC2K to the 24 …100Vdc DC bus power supply.
8. Protective earth (PE) connector: used to connect the device to the ground protection.
9. 100s display: used to view numbers >99; e.g. if the indicator is on and the display reads “03”, the
measurement is 103V.
10. Braking indicator: indicates that the unit is braking the engine and supplying current to the braking
R.
11. 7-segment display: when the unit is in operation, this shows the DC bus voltage (accuracy +/-1V);
it is also used to display menu items and error codes.
12. Alarm LED: indicates a fault or error status.
50
Motor brake controller
• 20 automatically activated threshold levels
• Each module can handle a braking power of 2 kW 115
• Connect up to 4 cards in parallel to run a braking power of 8 kW
• Simple function programming
• Braking resistor temperature control
128 Item available until supplies last
39
DC/DC power
supply Mosfet
Microprocessor
driver and
short circuit
protection
DC IN
51
Adjustable electronic overcurrent
protection from 1...10 A / 24 Vdc
According to the new EN60204-1, it is compulsory to protect wires on SELV-PELV lines from
overcurrent. The standard requires that 24 Vdc overcurrent protections intervene by cutting out the
failure before the control and command 24 Vdc falls below 21.6V, cutting off power to the controls and
preventing the emergency and safety features from activating.
Under EN 60204-1 and EN 61131-1 and -2, overcurrent protection on SELV/PELV lines must be capable
of isolating shorts within 10 ms and hazardous overcurrents within 5 s. The use of power supplies with
a high output overcurrent capacity and fast, accurate protections facilitates fault isolation before the 24
V falls below 21.6 V, leaving the controls without power. Figure 1
Fuses and magneto-thermal switches inserted on 24 Vdc lines have characteristic intervention I/ts
that are not suitable for isolating faults with the required speed and accuracy, while the fuses may be
replaced with different types, affecting the behaviour of the protection and the safety of the system.
The proper coordination of the circuit in which the overcurrent protection is inserted must consider the
total R of the line as: R connections + R wires + R protection + R residual malfunctioning load. The
total R must always allow a safe current to circulate in the circuit once the protection is triggered and
the protection should neither be undersized, to prevent undesirable bursts at peak load, nor oversized,
to prolong its intervention t.
The entire circuit, including power supply, protection, wiring and connections, must be designed such that
all overcurrents can be cut-off within 5 s before the 24 Vdc falls below 21.6 Vdc. This requirement can
be met with Cabur's CSF and CSG series power supplies, designed to provide a high output overcurrent
(nom. I >+50% for > 5s) and CEP System electronic overcurrent protections with an accuracy and speed
far superior to magneto-thermal switches and fuses, whose trigger t is independent of ambient T and
can be reset locally or remotely.
Protection features
MGTs have two different intervention curves: Thermal and magnetic. The magnetic relay only triggers
in the event of a short with different I/t curves; thermal relays all have the same intervention curve
regardless of the MGT curve and in the event of an overload they behave as shown in figure 2: overload
currents of 1.13 x In are cut in >1h, and at overcurrent > 1.45 x In, the trigger occurs in several minutes.
The disconnection of short-circuit currents is activated by the magnetic relay whose trigger t ranges from
0.01 to 0.1 s, and it occurs at very high currents which the power supply used may not be able to deliver:
a C5 MGT used in DC has a safe trigger of > 70 A, a current which only (but not all) power supplies with a
far higher nom. I, e.g. 40 A, are capable of providing, but which is not deliverable by 10 A power supplies.
Using MGT as an overcurrent protection, if the power supply used has an overload I 1.2 times greater
than its nominal I, disconnection will occur after 20…60 minutes, while with a current 2.5 times higher Figure 3
than the nominal I it will trigger after 25 s to 2 min., depending on the Tamb, times which are too long
to guarantee stability at 24V to protect wiring and protection selectivity. In case of malfunction, until the
protection triggers, the power supply remains in overload in excess of x 1.5 x 5 s and the 24 V falls below
21.6 V, leaving normal functions and particularly the safety functions without power.
Protection selectivity
In case of an overload or short, only the malfunctioning circuit is isolated from its protection without
any effects on the power to the other loads. This feature is obtained using power supplies with a high
overcurrent capacity and quick and precise protections.
Figure 5
52
Adjustable electronic
overcurrent protection
from 1...10 A / 24 Vdc
• Programmable from 1 A to 10 A in 1 A increments 115
• 3 programmable characteristic curves
• Remote or local ON/OFF control
• Green ON/red OFF status LED and remote signalling
• Slide contact for manual disconnection 116
• Sealable front cover for programming protection 8
E258138
➀ ➁ ➂
53
These tables are used for quickly identifying items and verifying whether all of the product’s technical details satisfy the set requirements.
54
3-phase filter without
neutral TDV series
C
• Models from 7 to 130 A
• Elevated attenuation from 150 kHz to 30 MHz
• Elevated attenuation even on long cables
• Minimum surface occupied on the panel B
PE Cy R2 PE
55
3-phase filter without
neutral TDS series
• Models from 150 to 180 A C
• Elevated attenuation from 150 kHz to 30 MHz PRELIMINARY
• Elevated attenuation even on long cables
PE PE
56
3-phase filter without
neutral TDDS series
• Elevated attenuation from 150 kHz to 30 MHz C
• Elevated attenuation even on long cables
A
Item available until supplies last
PE PE
57
3-phase filter without
neutral TDSS series
• Models from 300 to 600 A C
• Elevated attenuation from 150 kHz to 30 MHz
• Elevated attenuation even on long cables
A
Item available until supplies last
58
3-phase filter with neutral
TYT series
• Models from 16 to 100 A
• Elevated attenuation from 150 kHz to 30 MHz C
• Elevated attenuation even on long cables
N L4'
Cy Cy
PE PE
59
Compact 3-phase filter
with neutral TY series
• Models from 10 to 20 A
• Elevated attenuation from 150 kHz to 30 MHz C
• Elevated attenuation even on long cables
• Excellent quality/price/performance ratio
(2) Version made to order (not kept in stock); contact our sales L3 L3’
Cx Cx Cx
office for availability. L
N N
Cy
PE
60
Single-cell single-phase
filter DK series
• Models from 3 to 30 A
• Elevated attenuation from 150 kHz to 30 MHz
C
• Elevated attenuation even on long cables
• Minimum surface occupied on the panel
B
A
model. PE
61
Double-cell single-phase
filter DP series
• Models from 3 to 30 A
• Elevated attenuation from 150 kHz to 30 MHz C
• Elevated attenuation even on long cables
• Minimum surface occupied on the panel
62
Applications of analogue converters
and galvanic separation
T hey convert electrical signals generated by sensors which take physical measurements
such as temperature (thermocouples and PT100 resistance thermometers), frequency
(proximity, contacts, photocells), current (TA, Hall sensors), resistance (potentiometers), voltage,
pressure, level, etc. into standardised electrical signals, adapting them to PLC, DCS and indus-
trial PC (control) outputs, or they convert a given analogue signal into a different one, adapting
it to control inputs/outputs or allowing for long-distance signal transmission without interfer-
ence by means of galvanic separation (fig. 1).
SIGNAL ADAPTATION
fig. 1
Voltage signals can reach a max. distance of 10-20 m, beyond which they lose reliability and
become highly sensitive to induced and ground-derived interference, therefore in order to
transmit to distances beyond 20 m a voltage signal must be converted into a current signal
and galvanically separated (fig. 2).
Current signals can surpass a transmission distance of 300 m and are less sensitive to
induced interference. The long-distance transmission of a current signal requires galvanic
separation.
fig. 2
63
Galvanic signal separation
(signal isolation):
• isolates and electrically separates the sensor circuit from the control
circuit and from the power supply circuit; each circuit therefore operates
in relation to its own zero potential which, being isolated from other Measurement error
circuits, cannot be altered by ever-present potential differences between
different ground references (fig.3)
fig. 4
INTERFERENCE
fig. 5
U
CONVERTERS IN PARALLEL
fig. 7
64
These tables are used for quickly identifying items and verifying whether all of the product’s technical details satisfy the set requirements.
Current converters
Input Output Isolation Power supply Notes Type Cat. No. Page
0…50 A ac adjustable threshold 1…30 2-way 24 Vdc (3) (4) CCIS-2 XCCIS2 79
A
0…1 A ac/dc 0...10 V 3-way 24 Vdc (2) WAA 7-0540 X756540 80
0...20 / 4...20 mA
0…5 A ac/dc 0...10 V 3-way 24 Vdc (2) WAA 7-0541 X756541 80
0...20 / 4...20 mA
0…10 A ac/dc 0...10 V 3-way 24 Vdc (2) WAA 7-0542 X756542 80
0...20 / 4...20 mA
Notes
(1) version with single input and output signals (3) version with open collector threshold output
(2) version with three selectable output signals (4) version with threshold output with 1 exchange relay
65
These tables are used for quickly identifying items and verifying whether all of the product’s technical details satisfy the set requirements.
Notes
(1) software programmable input and output signals
(2) DIP-switch programmable input and output signals
66
Analogue programmable
signal converters
• 19 input steps 108
• 7 output steps
• 1 failure contact
• Input/Output isolation > 3 kVac
• Auxiliary power supply for loop powered sensors
119
• Potentiometer input 22.5
67
Programmable analogue
signal converter
• 3-way galvanic separation 79
• 14 programmable input ranges
• 3 programmable output ranges
• Simplified programming
• Version available with 24-240 Vac/dc power supply 84
17.5
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 —
Jumperred —
(16 poles, 16 A) white —
blue —
68
Programmable analogue
signal converters
• 1.5 kV 3-way input/output/power supply isolation 90
• 3 programmable input ranges
• 3 programmable output ranges
• Simplified, self-adjusting programming
• Version available with 24-240 Vac/dc power supply 92.5
6.2
Power supply
24 Vac/dc
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 —
Jumperred CWBK 7-0802 Cat. No. X766802 —
(16 poles, 16 A) white CWBK 7-0803 Cat. No. X766803 —
blue CWBK 7-0804 Cat. No. X766804 —
69
Analogue
signal converters
• 1.5 kV 3-way input/output/power supply isolation 90
• Fixed value
• Compact size, 6.2 mm thick
92.5
6.2
Power supply
24 Vac/dc
VERSIONS Cat. No. X756530 Cat. No. X756531 Cat. No. X756532 APPLICATIONS
IN: 0...10 V / OUT: 0...10 V CWAA 7-0530 Convert and galvanically isolate
IN: 0...10 V / OUT: 0...20 mA CWAA 7-0531 the main analogue signals into a
IN: 0...10 V / OUT: 4...20 mA CWAA 7-0532 proportional signal; each model is
INPUT TECHNICAL DATA designed to convert a single ana-
Input signal 0…10 V 0…10 V 0…10 V logue signal providing a substantial
Input resistance 330 kΩ 330 kΩ 330 kΩ reduction in components and costs,
making it the perfect solution for
large plants and applications which
OUTPUT TECHNICAL DATA use multiple signals of the same
Output signal 0...10 V 0...20 mA 4...20 mA type, where programmable cards
Applicable load >1 kΩ <400 Ω <400 Ω would drive up costs. Equipped with
3-way galvanic separation between
GENERAL TECHNICAL DATA input, output and power supply.
Power supply voltage 24 Vac/dc (1) 24 Vac/dc (1) 24 Vac/dc (1) Where multiple output channels are
Power consumption ≤ 13 mA ± 10% ≤ 13 mA ± 10% ≤ 13 mA ± 10% needed for a single signal source,
Accuracy 0.1% at 23°C FS 0.1% at 23°C FS 0.1% at 23°C FS multiple converters may be used
Conversion frequency < 30 Hz < 30 Hz < 30 Hz connecting the signal inputs in par-
Temperature coefficient 0.02% / K FS 0.02% / K FS 0.02% / K FS allel (with voltage signals) or in
Isolation 1.5 kVac / 60 s (2) 1.5 kVac / 60 s (2) 1.5 kVac / 60 s (2) series (with current signals).
EMC standards EN 61000-6-2, EN 61000-6-4 EN 61000-6-2, EN 61000-6-4 EN 61000-6-2, EN 61000-6-4
Reference Standards IEC 664-1, DIN VDE IEC 664-1, DIN VDE IEC 664-1, DIN VDE
Overvoltage category / Pollution degree III / 2 III / 2 III / 2
Protection degree IP 20 IEC 529, EN60529 IP 20 IEC 529, EN60529 IP 20 IEC 529, EN60529
Operating temperature range -25…+60°C -25…+60°C -25…+60°C
Connection type 2.5 mm² fixed screw terminal 2.5 mm² fixed screw terminal 2.5 mm² fixed screw terminal
blocks blocks blocks
Housing material PPE PPE PPE
Approximate weight 40 g 40 g 40 g
Mounting information vertical on rails, side by side vertical on rails, side by side vertical on rails, side by side
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 —
Jumperred CWBK 7-0802 Cat. No. X766802
(16 poles, 16 A) white CWBK 7-0803 Cat. No. X766803
blue CWBK 7-0804 Cat. No. X766804
70
Analogue
signal converters
• 1.5 kV 3-way input/output/power supply isolation 90
• Fixed value
• Compact size, 6.2 mm thick
92.5
6.2
Power supply
24 Vac/dc
VERSIONS Cat. No. X756533 Cat. No. X756534 Cat. No. X756535 APPLICATIONS
IN: 0...20 mA / OUT: 0...10 V CWAA 7-0533 (3) Convert and galvanically isolate
IN: 0...20 mA / OUT: 0...20 mA CWAA 7-0534 (3) the main analogue signals into a
IN: 0...20 mA / OUT: 4...20 mA CWAA 7-0535 (3) proportional signal; each model is
designed to convert a single ana-
INPUT TECHNICAL DATA logue signal providing a substantial
Input signal 0...20 mA 0...20 mA 0...20 mA reduction in components and costs,
Input resistance 100 Ω 100 Ω 100 Ω making it the perfect solution for
large plants and applications which
use multiple signals of the same
type, where programmable cards
OUTPUT TECHNICAL DATA would drive up costs. Equipped with
Output signal 0...10 V 0...20 mA 4...20 mA 3-way galvanic separation between
Applicable load >1 kΩ <400 Ω <400 Ω input, output and power supply.
Where multiple output channels are
needed for a single signal source,
GENERAL TECHNICAL DATA multiple converters may be used
Power supply voltage 24 Vac/dc (1) 24 Vac/dc (1) 24 Vac/dc (1) connecting the signal inputs in par-
Power consumption ≤ 13 mA ± 10% ≤ 13 mA ± 10% ≤ 13 mA ± 10% allel (with voltage signals) or in
Accuracy 0.1% at 23°C FS 0.1% at 23°C FS 0.1% at 23°C FS series (with current signals).
Conversion frequency < 30 Hz < 30 Hz < 30 Hz
Temperature coefficient 0.02% / K FS 0.02% / K FS 0.02% / K FS
Isolation 1.5 kVac / 60 s (2) 1.5 kVac / 60 s (2) 1.5 kVac / 60 s (2)
EMC standards EN 61000-6-2, EN 61000-6-4 EN 61000-6-2, EN 61000-6-4 EN 61000-6-2, EN 61000-6-4
Reference Standards IEC 664-1, DIN VDE IEC 664-1, DIN VDE IEC 664-1, DIN VDE
Overvoltage category / Pollution degree III / 2 III / 2 III / 2
Protection degree IP 20 IEC 529, EN60529 IP 20 IEC 529, EN60529 IP 20 IEC 529, EN60529
Operating temperature range -25…+60°C -25…+60°C -25…+60°C
Connection type 2.5 mm² fixed screw terminal 2.5 mm² fixed screw terminal 2.5 mm² fixed screw terminal
blocks blocks blocks
Housing material PPE PPE PPE
Approximate weight 40 g 40 g 40 g
Mounting information vertical on rails, side by side vertical on rails, side by side vertical on rails, side by side
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 —
Jumperred CWBK 7-0802 Cat. No. X766802
(16 poles, 16 A) white CWBK 7-0803 Cat. No. X766803
blue CWBK 7-0804 Cat. No. X766804
71
Analogue
signal converters
• 1.5 kV 3-way input/output/power supply isolation 90
• Fixed value
• Compact size, 6.2 mm thick
92.5
6.2
Power supply
24 Vac/dc
VERSIONS Cat. No. X756536 Cat. No. X756537 Cat. No. X756538 APPLICATIONS
IN: 4...20 mA / OUT: 0...10 V CWAA 7-0536 Convert and galvanically isolate
IN: 4...20 mA / OUT: 0...20 mA CWAA 7-0537 (3) the main analogue signals into a
IN: 4...20 mA / OUT: 4...20 mA CWAA 7-0538 proportional signal; each model is
INPUT TECHNICAL DATA designed to convert a single ana-
Input signal 4...20 mA 4...20 mA 4...20 mA logue signal providing a substantial
Input resistance 100 Ω 100 Ω 100 Ω reduction in components and costs,
making it the perfect solution for
large plants and applications which
OUTPUT TECHNICAL DATA use multiple signals of the same
Output signal 0...10 V 0...20 mA 4...20 mA type, where programmable cards
Applicable load >1 kΩ <400 Ω <400 Ω would drive up costs. Equipped with
3-way galvanic separation between
GENERAL TECHNICAL DATA input, output and power supply.
Power supply voltage 24 Vac/dc (1) 24 Vac/dc (1) 24 Vac/dc (1) Where multiple output channels are
Power consumption ≤ 13 mA ± 10% ≤ 13 mA ± 10% ≤ 13 mA ± 10% needed for a single signal source,
Accuracy 0.1% at 23°C FS 0.1% at 23°C FS 0.1% at 23°C FS multiple converters may be used
Conversion frequency < 30 Hz < 30 Hz < 30 Hz connecting the signal inputs in par-
Temperature coefficient 0.02% / K FS 0.02% / K FS 0.02% / K FS allel (with voltage signals) or in
Isolation 1.5 kVac / 60 s (2) 1.5 kVac / 60 s (2) 1.5 kVac / 60 s (2) series (with current signals).
EMC standards EN 61000-6-2, EN 61000-6-4 EN 61000-6-2, EN 61000-6-4 EN 61000-6-2, EN 61000-6-4
Reference Standards IEC 664-1, DIN VDE IEC 664-1, DIN VDE IEC 664-1, DIN VDE
Overvoltage category / Pollution degree III / 2 III / 2 III / 2
Protection degree IP 20 IEC 529, EN60529 IP 20 IEC 529, EN60529 IP 20 IEC 529, EN60529
Operating temperature range -25…+60°C -25…+60°C -25…+60°C
Connection type 2.5 mm² fixed screw terminal 2.5 mm² fixed screw terminal 2.5 mm² fixed screw terminal
blocks blocks blocks
Housing material PPE PPE PPE
Approximate weight 40 g 40 g 40 g
Mounting information vertical on rails, side by side vertical on rails, side by side vertical on rails, side by side
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 —
Jumperred CWBK 7-0802 Cat. No. X766802
(16 poles, 16 A) white CWBK 7-0803 Cat. No. X766803
blue CWBK 7-0804 Cat. No. X766804
72
Passive
galvanic isolators
90 90
• Do not require power supply
• Adapted to loop powered sensors
• 500 V 2-way input/output isolation
• One- and two-channel versions
• Compact size, 6.2 mm thick 92.5 115.5
6.2 6.2
fig. 1 fig. 2
73
Monitor module
for alanogue signal
90
• 3-way galvanic separation
• Dip-switch and FDT/DTM software programmable input ranges
• FDT/DTM software programmable output thresholds
• Simplified programming
115.5
6.2
3
_ + mA 6 3
_
+ 6 I
+
_ 7 I 2+
_ Pwr
1
+A 7 2 +
8 Power
DC 24 V
- GND _
8 1
74
Programmable
temperature/analogue
converter 90
• For PT100 and PT1000 sensors, thermocouples,
potentiometers
• 2.5 kV 3-way input/output isolation
• 145 DIP-switch selectable input ranges, customisable using 115.5
FDT/DTM software
6.2
• 5 DIP-switch selectable output ranges, customisable using
FDT/DTM software
• Compact size, 6.2 mm thick Programming kit X756894
75
Monitor module
for temperature sensor
90
• For PT100 and PT1000 sensors, thermocouples, potentiometers
• 2.5 kV 3-way input/output isolation
• 145 DIP-switch selectable input ranges, customisable using
FDT/DTM software
• Two FDT/DTM software programmable output thresholds 115.5
• Compact size, 6.2 mm thick 6.2
_ Pwr
6 KTY
7 _ 2 +
or customised using FDT/DTM software. 8 8
7
8 8 8 1
TC
7 2 +
(3) 3-way, IN/OUT/power supply Power
DC 24 V
_
8 1
TC 6 4
+
_
+
_ 3
2
1
_
+
Pwr
7
76
Programmable temperature
sensor converters
• Converters for PT100 sensors 79
• 3-way galvanic separation
• 8 programmable input ranges
• 3 programmable output ranges
• Simplified programming 84
• Version with 24-240 Vac/dc power supply 17.5
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 —
Jumperred —
(16 poles, 16 A) white —
blue —
77
Programmable temperature
sensor converters
• Converters for type J and K thermocouple sensors 79
• 3-way galvanic separation
• 8 programmable input ranges
• 3 programmable output ranges
• Simplified programming 84
• Version with 24-240 Vac/dc power supply 17.5
Power supply
24 Vac/dc
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 —
Jumperred —
(16 poles, 16 A) white —
blue —
78
Monitor module
for current signal
• For measuring AC currents
• Adjustable threshold value 93
• With transistor and relay output
• 3 kV Input/Output isolation
50
70
79
Current transducer
• For AC and DC current measurements
• Protected from transistors
90
• LED power supply indicator
• 3 programmable output ranges
115.5
6.2
DC 24V
VERSIONS Cat. No. X756540 Cat. No. X756541 Cat. No. X756542 APPLICATIONS
Input 0…1 A WAA 7-0540 Used for measuring an AC or DC
Input 0…5 A WAA 7-0541 current value by means of a “HALL”
Input 0…10 A WAA 7-0542 sensor. The presence of current in a
INPUT TECHNICAL DATA circuit indicates not only that volt-
Input signal 0…1 A AC/DC 0…5 A AC/DC 0…10 A AC/DC age is present, but that the circuit
Max. input voltage 400 V (1) 400 V (1) 400 V (1) is closed and the load connected
Connection of current conductor 1.5 mm2 screw-on terminal 1.5 mm2 screw-on terminal 1.5 mm2 screw-on terminal is active, as well as indicating the
block block block operating conditions of the con-
trol circuit. The module guarantees
OUTPUT TECHNICAL DATA VOLTAGECURRENT
galvanic separation between the
Output signal 0…10 V 0…20 mA / 4…20 mA current conductor and the analogue
Max. output signal 11 V 21 mA output.
Applicable load >1 kΩ <400 Ω
GENERAL TECHNICAL DATA
Power supply voltage 24 Vdc (16.8...30 Vdc) 24 Vdc (16.8...30 Vdc) 24 Vdc (16.8...30 Vdc)
Power consumption 13 mA 13 mA 13 mA
Operating temperature range -25…+60°C -25…+60°C -25…+60°C
Linearity error < 0.1% FS (23°C) < 0.1% FS (23°C) < 0.1% FS (23°C)
Offset error < 0.5% FS (23°C) < 0.5% FS (23°C) < 0.5% FS (23°C)
Temperature coefficient < 150 ppm / K FS < 150 ppm / K FS < 150 ppm / K FS Switch On S1
Response time 150 ms 150 ms 150 ms Input Output 1 2 3 4
Protection degree IP20 IP20 IP20 0-1A 0-10V
Connection type 1.5 mm2 screw-on terminal 1.5 mm2 screw-on terminal 1.5 mm2 screw-on terminal 0-1A 0-20mA
block block block 0-1A 4-20mA
Approximate weight 55 g 55 g 55 g
Mounting information on rails, side by side on rails, side by side on rails, side by side Range WAA7-0540
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB Switch On S1
Input Output 1 2 3 4
Mounting rail type according to IEC60715/G32 —
0-5A 0-10V
Jumperred CWBK 7-0802 Cat. No. X766802 0-5A 0-20mA
(16 poles, 16 A) white CWBK 7-0803 Cat. No. X766803 0-5A 4-20mA
blue CWBK 7-0804 Cat. No. X766804
Range WAA7-0541
Switch On S1
Input Output 1 2 3 4
0-10A 0-10V
0-10A 0-20mA
0-10A 4-20mA
Range WAA7-0542
80
Current / analogue
converters
• For AC and DC current measurements 94
• Protected from transistors
• LED power supply indicator
• Three available output signals
99
25
Item available until supplies last
MOUNTING ACCESSORIES
Mounting rail compliant with IEC60715/TH35 PR/3/AC, PR/3/AS
Mounting rail type according to IEC60715/G32 PR/DIN/AC, PR/DIN/AS, PR/DIN/AL
Jumperred —
(16 poles, 16 A) white —
blue —
81
Frequency / analogue
programmable converters
• Programmable frequency range 0...28.8 Khz 79
• 3 programmable analogue output signal ranges
• 2.5 kV 3-way input/output isolation
84
17.5
Shield- OUT-
AC/DC 24V
82
Auxiliary power supply for
sensors and potentiometers
• Stabilised switching converter 90
• IN 16.8…20 Vdc / 9…11 Vdc 60 mA
• Suitable for powering potentiometers and sensors
92.5
6.2 +4 24 Vdc +3
IN OUT
-5 -1
-6 9...11 Vdc -2
9...11 Vdc
NOTES BLOCK DIAGRAM APPLICATION EXAMPLES
Depth measurements include terminal block and rail
clamp clearance.
(1) range 16.8…30 Vdc
+4 24 Vdc +3 +3
+4 24 Vdc 0...10 V
IN OUT
-5 -1 -1
-5
-6 9...11 Vdc -2 10 Vdc 4...20 mA
83
Signal inverters
NPN and PNP
• Converts NPN sensors to PNP and vice versa
• Reduced overall dimensions 77
12
45
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AS
Mounting rail type according to IEC60715/G32 PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
Jumperred —
white —
blue —
CONNECTION EXAMPLES
PNP sensor
load
Conversion from PNP to NPN
NPN sensor
load
Conversion from NPN to PNP
84
These tables are used for quickly identifying items and verifying whether all of the product’s technical details satisfy the set requirements.
Number of Output
Input rated voltage Notes Type Cat. No. Page
relays type/no. of contacts contact current
1 12 Vdc 1 SC 10A (1) CM1C012 XCM1C012 88
1 12 Vdc 2 SC 5A (1) CM2C012 XCM2C012 89
1 12 Vac 1 SC 10A (1) CM1A012 XCM1A012 91
1 12 Vac 2 SC 5A (1) CM2A012 XCM2A012 92
1 12 Vac/dc 1 SC 6A (1) CWRE7-0848 X766848 95
1 24 Vdc 1 NA 5A (2) RFA024D XRFA024D 86
1 24 Vdc 1 SC 16A (1) RE1024D XRE1024D 86
1 24 Vdc 1 SC 16A (2) RF1024D XRF1024D 86
1 24 Vdc 1 SC 12A (1) CM1C024 XCM1C024 88
1 24 Vdc 1 SC 12A (1) RE1824D XRE1824D 86
1 24 Vdc 1 SC 12A (2) RF1824D XRF1824D 86
1 24 Vdc 2 SC 8A (1) CM2C024 XCM2C024 89
1 24 Vdc 4 SC 3A (1) CM4C024 XCM4C024 90
1 24 Vac/dc 1 SC 6A (1) CWRE7-0842 X766842 95
1 24 Vac/dc 1 SC 6A (2) (3) CKR16 XCKR16 94
1 24 Vac/dc 2 SC 8A (1) RE2024D XRE2024D 87
2 24 Vac/dc 2 NA 5A (2) CKR25 XCKR25 94
1 24 Vac 1 SC 12A (1) CM1A024 XCM1A024 91
1 24 Vac 2 SC 8A (1) CM2A024 XCM2A024 92
1 48 Vdc 1 SC 10A (1) CM1C048 XCM1C048 88
1 48 Vdc 2 SC 5A (1) CM2C048 XCM2C048 89
1 48 Vac/dc 1 SC 6A (1) CWRE7-0845 X766845 95
1 110 Vdc 1 SC 10A (1) CM1C110 XCM1C110 88
1 110 Vdc 2 SC 5A (1) CM2C110 XCM2C110 89
1 110...120 Vac/dc 1 SC 6A (1) CWRE7-0846 X766846 95
1 120 Vac 1 SC 10A (1) CM1A120 XCM1A120 91
1 120 Vac 2 SC 5A (1) CM2A120 XCM2A120 92
1 230 Vac 1 SC 6A (1) CWRE7-0847 X766847 95
1 230 Vac 1 SC 10A (1) CM1A230 XCM1A230 91
1 230 Vac 2 SC 5A (1) CM2A230 XCM2A230 92
Notes
(1) version with pluggable relay
(2) version with fixed relay
(3) safety fuse on contact
(4) no light alarm and protection diode
85
Single relay modules
R series
77 77 77
12 16.4 16.4
52 70 70
VERSIONS Cat. No. XRFA024D Cat. No. XR_1824D Cat. No. XR_1024D
Pluggable relay – RE1824D RE1024D
Fixed relay RFA024D (2) RF1824D RF1024D (2)
86
Single relay modules
R series
93
26
75
87
Single relay modules
CM series
• Pluggable relay
• Installation on omega rail or panel using centre screw
• Compact dimensions
• Cross and slotted screw 75
• Available plug-in jumper for potential distribution
16
68 Jumper available
VERSIONS Cat. No. XCM1C012 Cat. No. XCM1C024 Cat. No. XCM1C048 Cat. No. XCM1C110
12 Vdc CM1C012
24 Vdc CM1C024
48 Vdc CM1C048
110 Vdc CM1C0110
INPUT TECHNICAL DATA
Nominal voltage 12 Vdc ±10% 24 Vdc ±10% 48 Vdc ±10% 110 Vdc ±10%
Power consumption (1 channel) 44 mA ±10% 22 mA ±10% 12 mA ±10% 11 mA ±10%
Turn ON time 15 ms 15 ms 15 ms 15 ms
Turn OFF time 5 ms 5 ms 5 ms 20 ms
Protection circuit damping diode (2)
OUTPUT TECHNICAL DATA
Contact type 1 exchange AgSnO2 (3)
Nominal current (resistive load) 12 A / 250 Vac
Max. cut-off capacity 12 A
Max. fuse current —
GENERAL TECHNICAL DATA
Operating temperature range –10...+50°C
Coil isolation / contacts 4 kVac / 60 s
Isolation between output terminal blocks 1 kVac / 60 s (between open contact poles)
Protection degree IP 20 IEC 529, EN60529
Overvoltage category / Pollution degree III / 2
Reference Standards IEC 664-1, DIN VDE 0110.1
Power/status indicator Green LED (2)
Connection type AWG26-14 2.5 mm² screw clamp terminal blocks
Housing material UL94V-0 plastic
Approximate weight 54 g
Mounting information rail, side by side or panel using centre screw
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 —
Spare part relay (1) Cat. No. 8904039 Cat. No. 8904001 Cat. No. 8904008 Cat. No. 8904047
Jumperblack Cat. No. XCMB16B
white —
blue —
Jumper
88
Single relay modules
CM series
• Pluggable relay
• Installation on omega rail or panel using centre screw
• Compact dimensions
• Cross and slotted screw 75
• Available plug-in jumper for potential distribution
16
75 Jumper available
VERSIONS Cat. No. XCM2C012 Cat. No. XCM2C024 Cat. No. XCM2C048 Cat. No. XCM2C110
12 Vdc CM2C012
24 Vdc CM2C024
48 Vdc CM2C048
110 Vdc CM2C0110
INPUT TECHNICAL DATA
Nominal voltage 12 Vdc ±10% 24 Vdc ±10% 48 Vdc ±10% 110 Vdc ±10%
Power consumption (1 channel) 44 mA ±10% 22 mA ±10% 24 mA ±10% 11 mA ±10%
Turn ON time 15 ms 15 ms 15 ms 15 ms
Turn OFF time 5 ms 5 ms 5 ms 20 ms
Protection circuit damping diode
OUTPUT TECHNICAL DATA
Contact type 2 exchanges AgSnO2
Nominal current (resistive load) 8 A / 250 Vac
Max. cut-off capacity 8A
Max. fuse current —
GENERAL TECHNICAL DATA
Operating temperature range –10...+50°C
Coil isolation / contacts 4 kVac / 60 s
Isolation between output terminal blocks 1 kVac / 60 s (between open contact poles)
Protection degree IP 20 IEC 529, EN60529
Overvoltage category / Pollution degree III / 2
Reference Standards IEC 664-1, DIN VDE 0110.1
Power/status indicator Green LED
Connection type AWG26-14 2.5 mm² screw clamp terminal blocks
Housing material UL94V-0 plastic
Approximate weight 67 g
Mounting information rail, side by side or panel using centre screw
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 —
Spare part relay (1) Cat. No. 8904040 Cat. No. 8904002 Cat. No. 8904009 Cat. No. 8904054
Jumperblack Cat. No. XCMB16B
white —
blue —
Jumper
89
Single relay modules
CM series
• Pluggable relay
• Installation on omega rail or panel using centre screw
• Compact dimensions
• Cross and slotted screw 75
• Available plug-in jumper for potential distribution
27
68
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 —
Spare part relay (1) Cat. No. 8904030
Jumperblack Cat. No. XCMB27B
white —
blue —
Jumper
90
Single relay modules
CM series
• Pluggable relay
• Installation on omega rail or panel using centre screw
• Compact dimensions
• Cross and slotted screw 75
• Available plug-in jumper for potential distribution
16
Jumper available
68
VERSIONS Cat. No. XCM1A012 Cat. No. XCM1A024 Cat. No. XCM1A120 Cat. No. XCM1A230
12 Vdc CM1A012 (2)
24 Vdc CM1A024
120 Vdc CM1A120 (2)
230 Vdc CM1A230
INPUT TECHNICAL DATA
Nominal voltage 12 Vac ±10% 24 Vac ±10% 120 Vac ±10% 230 Vac ±10%
Power consumption (1 channel) 95 mA ±10% 48 mA ±10% 10.5 mA ±10% 6 mA ±10%
Turn ON time 15 ms 15 ms 15 ms 15 ms
Turn OFF time 10 ms 10 ms 10 ms 10 ms
Protection circuit —
OUTPUT TECHNICAL DATA
Contact type 1 exchange AgSnO2
Nominal current (resistive load) 12 A / 250 Vac
Max. cut-off capacity 12 A
Max. fuse current —
GENERAL TECHNICAL DATA
Operating temperature range –10...+50°C
Coil isolation / contacts 4 kVac / 60 s
Isolation between output terminal blocks 1 kVac / 60 s (between open contact poles)
Protection degree IP 20 IEC 529, EN60529
Overvoltage category / Pollution degree III / 2
Reference Standards IEC 664-1, DIN VDE 0110.1
Power/status indicator Green LED
Connection type AWG26-14 2.5 mm² screw clamp terminal blocks
Housing material UL94V-0 plastic
Approximate weight 54 g
Mounting information rail, side by side or panel using centre screw
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 —
Spare part relay (1) Cat. No. 8904016 Cat. No. 8904048 Cat. No. 8904049 Cat. No. 8904050
Jumperblack XCMB16B
white —
blue —
Jumper
91
Single relay modules
CM series
• Pluggable relay
• Installation on omega rail or panel using centre screw
• Compact dimensions
• Cross and slotted screw 75
• Available plug-in jumper for potential distribution
16
75 Jumper available
VERSIONS Cat. No. XCM2A012 Cat. No. XCM2A024 Cat. No. XCM2A120 Cat. No. XCM2A230
12 Vac CM2A012 (2)
24 Vac CM2A024
120 Vac CM2A120 (2)
230 Vac CM2A230
INPUT TECHNICAL DATA
Nominal voltage 12 Vac ±10% 24 Vac ±10% 120 Vac ±10% 230 Vac ±10%
Power consumption (1 channel) 95 mA ±10% 48 mA ±10% 10.5 mA ±10% 6 mA ±10%
Turn ON time 15 ms 15 ms 15 ms 15 ms
Turn OFF time 10 ms 10 ms 10 ms 10 ms
Protection circuit —
OUTPUT TECHNICAL DATA
Contact type 2 exchanges AgSnO2
Nominal current (resistive load) 8 A / 250 Vac
Max. cut-off capacity 8A
Max. fuse current —
GENERAL TECHNICAL DATA
Operating temperature range –10...+50°C
Coil isolation / contacts 4 kVac / 60 s
Isolation between output terminal blocks 1 kVac / 60 s (between open contact poles)
Protection degree IP 20 IEC 529, EN60529
Overvoltage category / Pollution degree III / 2
Reference Standards IEC 664-1, DIN VDE 0110.1
Power/status indicator Green LED
Connection type AWG26-14 2.5 mm² screw clamp terminal blocks
Housing material UL94V-0 plastic
Approximate weight 67 g
Mounting information rail, side by side or panel using centre screw
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 —
Spare part relay (1) Cat. No. 8904017 Cat. No. 8904055 Cat. No. 8904056 Cat. No. 8904057
Jumperblack Cat. No. XCMB16B
white —
blue —
Jumper
92
“CK” series interface system
This series of automation interfaces comprises a range of electromechanical relay modules, solid state
relays and passive interfaces in modular cases just 6 mm thick.
All of these products are housed in the new CK module (also available as a component holder module)
which, with its 6 2.5 mm² spring terminal blocks and 4 contacts for insertion of the innovative “easy
bridge”, makes it possible to create different, effective compositions with a significant saving in terms
of space and time.
The range currently comprises a series of products which can all be assembled together:
• Individual electromechanical relays with a single 6 A exchange protected by a replaceable fuse, frontal
status LED, AC/DC input and positive or negative coil common. NO OK
• Double electromechanical relays with a 5 A NO contact, frontal status LED, AC/DC input and positive
or negative coil common.
• Individual solid state relays for 5 A negative common loads protected by a replaceable fuse, frontal
status LED and positive or negative input common.
• Double solid state relays for 12-24 Vdc 2.5 A negative common loads with frontal status LED and
positive or negative input common. 1
• Cards with feed-through diode or common anode or cathode.
• Lamp testing modules.
• Distribution modules for common indication and distribution via PTC/CK/42 jumper.
The PTC/CK/42 quick connector jumper comprises a 42 pole comb with capacity for a maximum 4
current of 32 A, limited to the capacity of the 24 A terminal block, therefore in a plug-in jumper of e.g.
11 poles (1 common and 10 distribution) 2.4 A can be distributed per pole.
The jumper is designed to be extremely simple and economical, with an innovative terminal block that
isolates the jumper and a connection system that is not only fast, but requires no specific tools to use.
• the jumper should be divided as required simply using nail clippers, close to the pole to maintain a
protection degree IP20 (1 and 2),
• insert the jumper into the relevant terminal block hole (3),
• use a screwdriver to push the jumper in until it locks. The jumper will now be completely isolated (4),
• to remove the jumper simply insert a screwdriver into the jumper slot, lift it and slide it out (5 and 6). 5
93
Single relay modules
CKR series
91 91
• Replaceable contact safety fuse
• Positive or negative common AC/DC input
• Frontal status LED, reverse polarity protection, coil damp-
ing diode
• Width 6 mm 100 100
• Available plug-in jumper for potential distribution 6 6
MOUNTING ACCESSORIES
Mounting rail compliant with IEC60715/TH35 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 — —
Spare part relay (1) — —
Jumper— Cat. No. PTCCK42 (42 poles) Cat. No. PTCCK42 (42 poles)
Marking tag neutral Cat. No. NU0851 Cat. No. NU0851
End section Cat. No. XCKPT Cat. No. XCKPT
94
Single relay modules
CKR series
• Pluggable relay
• Frontal status LED
• Width 6.2 mm 89
• Available plug-in jumper for potential distribution
77
6.2
VERSIONS Cat. No. X766848 Cat. No. X766842 Cat. No. X766845 Cat. No. X766846 Cat. No. X766847
12 Vac/dc (1) CWRE7-0848 (1)
24 Vac/dc CWRE7-0842
48 Vac/dc (1) CWRE7-0845 (1)
115 Vac/dc CWRE7-0846
230 Vac/dc CWRE7-0847
INPUT TECHNICAL DATA
Nominal voltage 12 Vac/dc ±10% 24 Vac/dc ±10% 48 Vac/dc ±10% 115 Vac/dc ±10% 230 Vac/dc ±10%
Power consumption (1 channel) 10 mA ±10% 7 mA ±10% 5 mA ±10% 4 mA ±10% 4 mA ±10%
Turn ON time 8 ms 8 ms 7 ms 8 ms 8 ms
Turn OFF time 5 ms 5 ms 7 ms 13 ms 13 ms
Protection circuit damping diode, reverse polarity protection diode jumper
OUTPUT TECHNICAL DATA
Contact type 1 exchange AgSnO2 (3)
Nominal current (resistive load) 6 A / 250 Vac ; 6 A / 30 Vdc
Max. cut-off capacity DC 13: 24 V / 1A; 115V / 200 mA; 230 V / 100 mA
Max. fuse current —
GENERAL TECHNICAL DATA
Operating temperature range -40...+70°C
Coil isolation / contacts 4 kVac / 60 s
Isolation between output terminal blocks 1 kVac / 60 s (between open contact poles)
Protection degree IP 20 IEC 529, EN60529
Overvoltage category / Pollution degree III / 2
Reference Standards IEC 664.1, DIN VDE 0110.1
Power/status indicator Green LED
Connection type AWG26-14 2.5 mm² screw clamp terminal blocks
Housing material UL94V-0 plastic
Approximate weight 35 g
Mounting information on rails, side by side
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 —
Spare part relay (2) Cat. No. 8904027
Cross connection bridge black —
white —
blue CWBK7-0813 (Cat. No. X766813) (20 poles)
Marking tag neutral Cat. No. NUPUTUK50
End section —
95
These tables are used for quickly identifying items and verifying whether all of the product’s technical details satisfy the set requirements.
Number of Output
Nominal voltage input nominal current Notes Type Cat. No. Page
relays type/no. of contacts
4 24 Vdc SPDT 12 A (1) (4) R41E24 XR041E24 97
8 24 Vdc SPDT 12 A (1) (4) R81E24 XR081E24 97
16 24 Vdc SPDT 12 A (1) (4) R161E24 XR161E24 97
4 24 Vac/dc SPDT 12 A (1) (6) R41EAD XR041EAD 98
8 24 Vac/dc SPDT 12 A (1) (6) R81EAD XR081EAD 98
16 24 Vac/dc SPDT 12 A (1) (6) R161EAD XR161EAD 98
4 24 Vac/dc SPDT 12 A (1) (6) (8) R41U24F XR041U24F 99
8 24 Vac/dc SPDT 12 A (1) (6) (8) R81U24F XR081U24F 99
16 24 Vac/dc SPDT 12 A (1) (6) (8) R161U24F XR161U24F 99
4 24 Vdc DPDT 8A (1) (4) R42E24 XR042E24 100
8 24 Vdc DPDT 8A (1) (4) R82E24 XR082E24 100
16 24 Vdc DPDT 8A (1) (4) R162E24 XR162E24 100
4 24 Vac/dc DPDT 8A (1) (6) R42EAD XR042EAD 101
8 24 Vac/dc DPDT 8A (1) (6) R82EAD XR082EAD 101
16 24 Vac/dc DPDT 8A (1) (6) R162EAD XR162EAD 101
8 24 Vac/dc SPDT 12 A (1) (6) (9) (10) RMP081CM XRMP081CM 102
4 110 Vdc/120 Vac SPDT 10 A (1) (6) R41E11A XRO41E1A 103
4 24 Vac/dc SPDT 8A (2) (6) CR4-1 XCR41 103
4 24 Vac/dc SPDT 8A (1) (6) CRE4-1 XCRE41 103
8 24 Vac/dc SPST(NO) 8A (1) (6) CRE8-1 XCRE81 103
8 24 Vac/dc SPST(NO) 8A (2) (6) CR8-1 XCR81 103
4 24 Vac/dc DPDT 8A (2) (6) CR4-2SC XCR42SC 104
4 24 Vac/dc DPDT 8A (1) (6) CRE4-2SC XCRE42SC 123
Notes
(1) pluggable relay version (6) universal common, negative DC control, positive DC, AC
(2) fixed relay version (7) control via connector
(3) base without relay (8) safety fuse on contact
(4) negative common, positive control (9) with test button
(5) positive common, negative control (10) with test switch
96
Multi-relay modules
• Control with direct current voltages
• Operation with negative common
• LED status indicator
• Pluggable relay 93 93 93
70 137 250
75 75 75
4 relay module
VERSIONS Cat. No. XR041E24 Cat. No. XR081E24 Cat. No. XR161E24
4 relay module R41E24
8 relay module R81E24
16 relay module R161E24
INPUT TECHNICAL DATA
Nominal voltage 24 Vdc ± 10%
Power consumption (1 channel) 22 mA ± 10%
Turn ON time 15 ms
Turn OFF time 5 ms
Protection circuit damping diode, reverse polarity protection diode
97
Multi-relay modules
• Control with both alternating and direct current
voltages
• Operation with both positive and negative
common
• LED status indicator 93 93 93
• Pluggable relay
70 137 250
75 75 75
4 relay module
VERSIONS Cat. No. XR041EAD Cat. No. XR081EAD Cat. No. XR161EAD
4 relay module R41EAD
8 relay module R81EAD
16 relay module R161EAD
INPUT TECHNICAL DATA
Nominal voltage 24 Vac/dc ± 10%
Power consumption (1 channel) 22 mA ± 10%
Turn ON time 15 ms
Turn OFF time 5 ms
Protection circuit damping diode, reverse polarity protection diode jumper
98
Multi-relay modules
with fuse
• Control with both alternating and direct current
voltages
• Operation with both positive and negative
common 93 93 93
• LED status indicator
• Pluggable relay
• Output contact safety fuse
70 137 250
75 75 75
4 relay module
VERSIONS Cat. No. XR041U24F Cat. No. XR081U24F Cat. No. XR161U24F
4 relay module R41U24F
8 relay module R81U24F
16 relay module R161U24F
INPUT TECHNICAL DATA
Nominal voltage 24 Vac/dc ± 10%
Power consumption (1 channel) 22 mA ± 10%
Turn ON time 15 ms
Turn OFF time 10 ms
Protection circuit damping diode, reverse polarity protection diode jumper
99
Multi-relay modules
• Control with direct current voltages
• Operation with negative common
• LED status indicator
• Pluggable relay 93 93 93
70 137 250
75 75 75
VERSIONS Cat. No. XR042E24 Cat. No. XR082E24 Cat. No. XR162E24 4 relay module
4 relay module R42E24
8 relay module R82E24
16 relay module R162E24
INPUT TECHNICAL DATA
Nominal voltage 24 Vdc ± 10%
Power consumption (1 channel) 22 mA ± 10%
Turn ON time 15 ms
Turn OFF time 10 ms
Protection circuit damping diode, reverse polarity protection diode
100
Multi-relay modules
• Control with both alternating and direct current
voltages
• Operation with both positive and negative
common
• LED status indicator 93 93 93
• Pluggable relay
70 137 250
75 75 75
VERSIONS Cat. No. XR042EAD Cat. No. XR082EAD Cat. No. XR162EAD 4 relay module
4 relay module R42EAD
8 relay module R82EAD
16 relay module R162EAD
INPUT TECHNICAL DATA
Nominal voltage 24 Vac/dc ± 10%
Power consumption (1 channel) 22 mA ± 10%
Turn ON time 15 ms
Turn OFF time 5 ms
Protection circuit damping diode, reverse polarity protection diode jumper
101
Multi-relay modules
with test buttom
• Control with both alternating and direct current
voltages
• Operation with both positive and negative
common 93
• LED status indicator
• Pluggable relay
• Test with buttons and switches 136
75
MOUNTING ACCESSORIES
Mounting rail compliant with IEC60715/TH35 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
Spare part relay (1) Cat. No. 8904001
Jumperred —
white —
blue —
102
Super compact
relay modules
CR & CRE series
• 3 kV Input/Output isolation 108 108
• 1 kV isolation between output contacts
• Fast cabling extractable terminal blocks
• Control with both alternating and direct current
voltages
119 119
• Operation with both positive and negative A A
common
A = 22.5 mm CR version, 35 mm CRE version A = 22.5 mm CR version, 35 mm CRE version
VERSIONS Cat. No. XCRE41 Cat. No. XCR4 Cat. No. XCRE81 Cat. No. XCR81
Pluggable relay CRE4-1 CRE8-1
Fixed relay CR4-1 CR8-1
MOUNTING ACCESSORIES
Mounting rail compliant with IEC60715/TH35 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 PR/DIN/AC - PR/DIN/AS - PR/DIN/AL PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
Spare part relay (1) Cat. No. 8904042 Cat. No. 8904042
Jumperred — —
white — —
blue — —
103
Super compact
relay modules
CR & CRE series
• 3 kV Input/Output isolation 108
• 1 kV isolation between output contacts
• Fast cabling extractable terminal blocks
• Control with both alternating and direct current
voltages
119
• Operation with both positive and negative A
common
A = 22.5 mm CR version, 35 mm CRE version
MOUNTING ACCESSORIES
Mounting rail compliant with IEC60715/TH35 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
Spare part relay (1) Cat. No. 8904052
Jumperred —
white —
blue —
104
Siemens S7 PLC
(300 and 400)
interface modules
• Super compact size with CR version 108
• Fast cabling
• Pluggable relay
119
A
MOUNTING ACCESSORIES
Mounting rail compliant with IEC60715/TH35 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 —
Spare part relay (1) Cat. No. 8904042
Jumperred —
white —
blue —
105
These tables are used for quickly identifying items and verifying whether all of the product’s technical details satisfy the set requirements.
Input modules
Number of Applicable load
Input voltage Notes Type Cat. No. Page
channels Voltage Current
1 5...24 Vdc 5…48 Vdc 3A (2) O332060 XO332060 107
1 5…24 Vdc 5…48 Vdc 500 mA (2) CWOT 6-2082 X766082 113
1 12…24 Vdc 5…48 Vdc 500 mA (2) CWOT 6-2083 X766083 112
1 12…24 Vdc 5…48 Vdc 5A (1) CM1S024E XCM1S024E 108
1 24 Vdc 5…48 Vdc 2A (1) CM1S024 XCM1S024 108
1 5…12 Vdc 5…24 Vdc 5A (2) (4) CKS15NA XCKS15NA 110
1 5…24 Vdc 5…24 Vdc 30 mA (2) CKS1S XCKS1S 113
1 24 Vdc 5…24 Vdc 5A (2) (4) CKS15NB XCKS15NB 110
1 5...24 Vdc 5...24 Vdc 5A (2) (5) CKS15E XCKS15E 111
1 12…24 Vdc 12...240 Vac 3A (1) CM1T024E XCM1T024E 109
1 5...24 Vdc 24...240 Vac 4A (2) O332240 XO332240 107
1 24 Vdc 48...240 Vac 2A (1) CM1T024 XCM1T024 109
2 12…24 Vdc 12…24 Vdc 2 x 2.5 A (2) CKS22 XCKS22 109
4 24 Vdc 5…48 Vdc 2A (1) (3) (4) R41S24F XR041S24F 116
4 24 Vdc 5…48 Vdc 2A (1) (3) R42S24 XR042S24 114
4 24 Vdc 48...240 Vac 2A (1) (3) R42T24 XR042T24 115
8 24 Vdc 5…48 Vdc 2A (1) (3) (4) R81S24F XR081S24F 116
8 24 Vdc 5…48 Vdc 2A (1) (3) R82S24 XR082S24 114
8 24 Vdc 48...240 Vac 2A (1) (3) R82T24 XR082T24 115
8 5...24 Vdc 12...24 Vdc 8 x 2.5 A (2) (5) COP082 XCOP082 117
16 24 Vdc 5…48 Vdc 2A (1) (3) (4) R161S24F XR161S24F 116
16 24 Vdc 5…48 Vdc 2A (1) (3) R162S24 XR162S24 114
16 24 Vdc 48...240 Vac 2A (1) (3) R162T24 XR162T24 115
106
Single solid state relay
• Fixed relay
• Reduced overall dimensions
77 77
12 12
54 54
MOUNTING ACCESSORIES
Mounting rail compliant with IEC60715/TH35 PR/3/AC, PR/3/AS PR/3/AC, PR/3/AS
Mounting rail type according to IEC60715/G32 PR/DIN/AC - PR/DIN/AS - PR/DIN/AL PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
Spare part relay (1) — —
Jumperred — —
white — —
blue — —
4 4
3 3
(DC)
Iout (DC)
Iout (DC)
(AC)
2 2
Iout
Iout
1 1
20 30 40 50 60 70 80 90 100 20 30 40 50 60 70 80 90 100
Ambient Temperature (°C) Ambient Temperature (°C)
107
Single solid state relay
CM series
• Low cost
• For switching loads in DC (version S)
• Pluggable relay
75 75
16 16
68 68
MOUNTING ACCESSORIES
Mounting rail compliant with IEC60715/TH35 PR/3/AC, PR/3/AS PR/3/AC, PR/3/AS
Mounting rail type according to IEC60715/G32 — —
Spare part relay (1) Cat. No. 8904404 Cat. No. 8904402
Jumperblack Cat. No. XCMB16B Cat. No. XCMB16B
white — —
blue — —
Jumper
108
Single solid state relay
CM series
• Low cost
• For switching loads in DC (version S)
• Pluggable relay
75 75
16 16
68 68
MOUNTING ACCESSORIES
Mounting rail compliant with IEC60715/TH35 PR/3/AC, PR/3/AS PR/3/AC, PR/3/AS
Mounting rail type according to IEC60715/G32 — —
Spare part relay (1) Cat. No. 8904405 Cat. No. 8904403
Jumperblack Cat. No. XCMB16B Cat. No. XCMB16B
white — —
blue — —
Jumper
109
Solid State Relay
with output protection
• Protection against short circuit, overload,overtemperature
91
• Input and output status LED
• Output extravoltage suppressor diode
• Extralow current absorbing
• Compact dimension
100
6
LOAD
LOAD
LOAD
A2– A2– A2–
operating temperature, for more accuracy or to pro-
OUT OUT OUT
tect cables with small section or rated current lower – – –
than the maximum current, an external fuse must be GND FAIL GND FAIL GND
provided.
110
Solid State Relaya
with output for
AC loads
• Output extravoltage varistor 91
• Extralow current absorbing
• Compact dimension
100
6
LOAD
A2–
purpose to avoid damages in the even of failure of IN
the external protection.
LOAD
Maximun current 6A
Min. applicable load 24 Vac / 10 mA
Leakage current 0 signal < 25 μA at 24 Vdc
Isolation between open contacts —
Internal protection not replaceable fuse 10 A / varistor (2)
External protection fuse 5 A max.
GENERAL TECHNICAL DATA
Operating temperature -20 ... +45°C
I/O isolation 3 kVac / 60 s
Max. switching frequency —
Status display LED green IN
Protection degree IP20 IEC529 EN60529 (with end plate on the last module)
Reference Standard —
Pollution degree 2
Overvoltage category II
Connection terminals 2.5 mm² (AWG26-14) fixed spring type
Housing material Polyamide UL94V-0
Approx. weight 30 g (1.06 oz)
Mounting information vertical on rail adjacent without gap
MOUNTING ACCESSORIES
Mounting rail type IEC60715/TH35-7,5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
111
Solid state single relay
with SPDT output
• 10…40 Vdc operating voltage
• Output with exchange contact simulation
79
• 5...48 Vdc 500 mA output voltage
• Commutation frequency up to 1 KHz
• 3.75 kV Input/Output isolation
84
6.2
MOUNTING ACCESSORIES
Mounting rail compliant with IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 —
Spare part relay (1) —
Jumper— —
Marking tag neutral —
marked —
marked —
End section —
112
Signal optoisolators
• Suitable for the isolation and transmission of high-frequency
digital signals
• Status LED 91 79
• 5, 12 and 24 Vdc operating voltages
• Input/Output isolation
100
84
6 6.2
MOUNTING ACCESSORIES
Mounting rail compliant with IEC60715/TH35-7.5 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 — —
Spare part relay (1) — —
Jumper— Cat. No. PTCCK42 (42 poles) —
Marking tag neutral Cat. No. NU0851 —
marked — —
marked — —
End section Cat. No. XCKPT —
113
Multi-solid
state relay
modules
• For switching loads in DC 93 93 93
• Pluggable relay
70 137 250
75 75 75
VERSIONS Cat. No. XR042S24 Cat. No. XR082S24 Cat. No. XR162S24
4 relay module R42S24 (2) 4 relay module
8 relay module R82S24 (2)
16 relay module R162S24 (2)
INPUT TECHNICAL DATA
Input voltage 24 Vdc (19.2…28.8 Vdc)
Signal 1 input level > 19.2 Vdc
Signal 0 input level < 1 Vdc
Power consumption (1 channel) < 20 mA
Commutation frequency 100 Hz max
114
Multi-solid
state relay
modules
• For switching loads in DC 93 93 93
• Pluggable relay
70 137 250
75 75
75
VERSIONS Cat. No. XR042T24 Cat. No. XR082T24 Cat. No. XR162T24 4 relay module
4 relay module R42T24 (2)
8 relay module R82T24 (2)
16 relay module R162T24 (2)
INPUT TECHNICAL DATA
Input voltage 24 Vdc (19.2…28.8 Vdc)
Signal 1 input level > 19.2 Vdc
Signal 0 input level < 1 Vdc
Power consumption (1 channel) < 20 mA
Commutation frequency 100 Hz max
16 relay module
MOUNTING ACCESSORIES
Mounting rail compliant with IEC60715/TH35 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
Spare part relay (1) Cat. No. 8904405
Jumper —
115
Multi-solid state relay
modules with fuse
• For switching loads in DC
• Safety fuse on output
• Pluggable relay 93 93 93
67 137 250
75 75 75
VERSIONS Cat. No. XR041S24F Cat. No. XR081S24F Cat. No. XR161S24F 4 relay module
4 relay module R41S24F (3)
8 relay module R81S24F (3)
16 relay module R161S24F (3)
INPUT TECHNICAL DATA
Input voltage 24 Vdc (19.2…28.8 Vdc)
Signal 1 input level > 19.2 Vdc
Signal 0 input level < 1 Vdc
Power consumption (1 channel) < 20 mA
Commutation frequency 100 Hz max
116
Solid state 24 Vdc
relay modules with
electronic protection
• Nominal output current 8 x 2.5 A / 5 - 33 Vdc
• outputs protected against short-circuit, overload, 93
over temperature and surge;
• Negative common 12-24 Vdc input, 8 status LEDs
K1 and K8 70 Item available until supplies last
• 8 “output OK” LED indicators, reverse polarity
protection diode on input and output 70
• Width 70 mm
MOUNTING ACCESSORIES
Mounting rail compliant with IEC60715/TH35 PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
Spare part relay (1) —
Jumper —
117
These tables are used for quickly identifying items and verifying whether all of the product’s technical details satisfy the set requirements.
118
Passive interfaces
(D-Sub/terminal blocks)
ISD Series
C C C
A A A
B B B
1 2 9 15 25 37
1 2 9 15 25 37 50 1 2 9 15 25 37 50
1 2 9 15 25 37
MOUNTING ACCESSORIES
Mounting rail compliant with IEC60715/TH35 PR/3/AC - PR/3/AS
Mounting rail type according to IEC60715/G32 PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
Jumperblack —
119
Passive interfaces
(D-Sub/terminal blocks)
CPD Series
C C
• Small size
A A
B B
1 2 9 15 25 37 50 1 2 9 15 25 37 50
MOUNTING ACCESSORIES
Mounting rail compliant with IEC60715/TH35 PR/3/AC - PR/3/AS
Mounting rail type according to IEC60715/G32 PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
Jumperblack —
120
Passive interfaces
(Flat-cable/terminal
blocks) IF Series
C
• With warning light
1 2 20 26 34 40 50
MOUNTING ACCESSORIES
Mounting rail compliant with IEC60715/TH35 PR/3/AC - PR/3/AS
Mounting rail type according to IEC60715/G32 PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
Jumperblack —
121
Passive interfaces
(Flat-cable/terminal
blocks) CPC Series
C
• Small size
1 2 20 26 34 40 50
MOUNTING ACCESSORIES
Mounting rail compliant with IEC60715/TH35 PR/3/AC - PR/3/AS
Mounting rail type according to IEC60715/G32 PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
Jumperblack —
122
Component-holder
modules CCM Series
• Small size
C C
A A
B B
C 1 3 5 7 1 2 3 4 5 6 7 8
MOUNTING ACCESSORIES
Mounting rail compliant with IEC60715/TH35 PR/3/AC - PR/3/AS
Mounting rail type according to IEC60715/G32 PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
Jumperblack —
123
Feed-through diode
modules CDM Series
C C C
A A A
B B B
1A 2A 3A 4A 5A 6A 7A 8A 16A 24A
1C 2C 3C 4C 5C 6C 7C 8C 16C 24C
MOUNTING ACCESSORIES
Mounting rail compliant with IEC60715/TH35 PR/3/AC - PR/3/AS
Mounting rail type according to IEC60715/G32 PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
Jumperblack —
124
Diode modules
with common CDM Series
A
B
1 3 5 7 15 23 1 3 5 7 15 23
C 2 4 6 8 16 24 C 2 4 6 8 16 24
MOUNTING ACCESSORIES
Mounting rail compliant with IEC60715/TH35 PR/3/AC - PR/3/AS
Mounting rail type according to IEC60715/G32 PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
Jumperblack —
125
LED testing modules
CLT Series
• Compact dimensions
• Integrated limitation resistance C
• Suitable only for LEDs without limitation resistance
• Not suitable for LED lamps fitted with an integrated
limitation circuit
A
B
MOUNTING ACCESSORIES
Mounting rail compliant with IEC60715/TH35 PR/3/AC – PR/3/AC/ZB – PR/3/AS – PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
Jumperblack —
126
Lamp testing modules
CLP Series
• Compact dimensions
• Suitable for LED lamps with limitation resistance C
A
B
MOUNTING ACCESSORIES
Mounting rail compliant with IEC60715/TH35 PR/3/AC – PR/3/AC/ZB – PR/3/AS – PR/3/AS/ZB
Mounting rail type according to IEC60715/G32 PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
Jumperblack —
127
Electronic circuit housing
CH Series
CH-B12.5
• Modular in 3 sizes
CH-C
CH-S CH-CA
CH-C10 CH-C22.5 CH-C32.5
(the total housing width is obtained by adding the width of the base (12.5
mm) to the width of the cover selected from the 4 available sizes)
Max
internal CH-CA
height
CH-B12.5 CH-C10 CH-C22.5 CH-C32.5 CH-S
CH-C
(1)
19.1 mm 1 1 1 2
31.6 mm 1 1 1 2
41.6 mm 1 1 1 2
128
Electronic circuit housing
CK Series
• Expandable cards with 6 mm clearance
• 6 x 2.5 mm2 spring terminal blocks on both the base and
the expansions
• Jumper can be connected on all 4 levels
• Openable front inspection window
129
“CK” Series accessories
PTC/CK/42 jumper
Notes:
(1) Example of a bridge cut into nine poles
(1)
(2) Protection degree refers to the bridge installed following the
applicable instructions
(3) Capacity allows for a maximum current of 32 A, limited to the
capacity of the 24 A terminal block, therefore in a plug-in jumper
of e.g. 11 poles (1 common and 10 distribution) 2.4 A can be
distributed per pole. VERSIONS Type Cat. No.
PTC/CK/42 PTCCK42
VERSIONS Type Cat. No. Type Cat. No. Type Cat. No.
CWBK 7-0802 X766802 CWBK 7-0803 X766803 CWBK 7-0804 X766804
130
“CM” Series accessories CMB
Series jumpers
Marking systems
Notes:
White polyamide marking tags to number the
terminal blocks of the CK Series cards and
CWRE Series converters. To be directly inserted
in dedicated holders before or after rail mount-
ing preparation.
They come in packages of 15 cards of 100
marking tags each, for a total of 1,500 mark-
ing tags.
The table shows only blank marking tags, avail-
able in packages of 1,500 pieces each, which
can be written on manually using special pens
or printed using an industrial marking system.
In particular, the marking tags shown here can
be printed using the innovative CaburJet
Type CNU/8/51 Cat. No. NU0851 Type NUPUTUK50 Cat. No. NUPUTUK50
system and with the CaburPlot plotter.
In addition to blank marking tags, CNU/8/51
preprinted marking tags are also available with Description Type Cat. no.
alpha-numeric characters and with the most Marking tags for marking CK Series cards CNU/8/51 NU0851
common electrical symbols.
For more information, please consult the Marking tags for marking CWRE Series converters NUPUTUK50 NUPUTUK50
Industrial Marking Systems catalogue.
Power supply
mounting bracket
17
40
9
2
131
DIN rail clamp
DIMENSIONS
DIMENSIONS
38 9.70 38 10
20 20
10
10
50
97.50
78
95.10
132
Mounting rails
• conforming to IEC 60715/TH35 - 7.5
• conforming to IEC 60715/TH35 - 15
• supports for TH/35 rail
133
Mounting rails
• conforming to IEC 60715/TH35 - 7.5 “G32” type
• conforming to IEC 60715/TH15 - 5.5
134
Type index
ID NUMBER PAGE ID NUMBER PAGE ID NUMBER PAGE ID NUMBER PAGE ID NUMBER PAGE
AR6 42 CM1A012 91 CSD30E 12 CWBK7-0802 130 ISD09FM 119
CAPIPO3 67 CM1A024 91 CSD30F 12 CWBK7-0803 130 ISD09PF 119
CCIS2 79 CM1A120 91 CSD50B 13 CWBK7-0804 130 ISD09PM 119
CCM08CV 123 CM1A230 91 CSD70C 14 CWBK7-0813 130 ISD15FM 119
CCM08SV 123 CM1C012 88 CSF120C 18 CWCV7-6184 83 ISD15PF 119
CCM16CV 123 CM1C024 88 CSF120CP 18 CWNAA7-0539 69 ISD15PM 119
CCM16SV 123 CM1C048 88 CSF120DP 18 CWNFA6-0524 82 ISD25FM 119
CCM24SV 123 CM1C110 88 CSF240C 19 CWOT6-2082 113 ISD25PF 119
CDIN-2 132 CM1S024 108 CSF240CP 19 CWOT6-2083 112 ISD25PM 119
CDIN-4 132 CM1S024E 108 CSF240DP 19 CWPAA7-0526 73 ISD37FM 119
CDIN-5 132 CM1T024 109 CSF30C 16 CWPAA7-0527 73 ISD37PF 119
CDINM45 132 CM1T024E 109 CSF500C 20 CWPT6-0816 77 ISD37PM 119
CDM08AC 125 CM2A012 92 CSF500D 20 CWRE7-0842 95 LCONALSFDT 74
CDM08CC 125 CM2A024 92 CSF5-65 21 CWRE7-0845 95 LCONTADFDT 75
CDM08CS 124 CM2A120 92 CSF85B 17 CWRE7-0846 95 LCONTLSFDT 76
CDM16AC 125 CM2A230 92 CSF85C 17 CWRE7-0847 95 LCONZBUSB 74
CDM16CC 125 CM2C012 89 CSF85CP 17 CWRE7-0848 95 MBC2K 51
CDM16CS 124 CM2C024 89 CSG2401C 37 CWTH6-0844 78 NUPUTUK50 131
CDM24AC 125 CM2C048 89 CSG2401D 37 CWUAA6-0516 68 O332060 107
CDM24CC 125 CM2C110 89 CSG2401G 38 F03DKBG5B 61 O332240 107
CDM24CS 124 CM4C024 90 CSG2401R 38 F03DPCG5C 62 PTC/CK/42 130
CEP-BCB 53 CMB27B 131 CSG481C 33 F06DKBG5B 61 R161E24 97
CEP-BCR 53 CNU/8/51 131 CSG500C 34 F06DPCG5C 62 R161EAD 98
CEP-D1 53 COP082 117 CSG500G 34 F07TDVST2 55 R161S24F 116
CEP-D2 53 CPC20M 122 CSG720C 35 F100TDVST2 55 R161U24F 99
CEP-MTW 53 CPC26M 122 CSG720D 35 F100TYT8 59 R162E24 100
CEP-RCC 53 CPC34M 122 CSG960C 36 F10TYG9 60 R162EAD 101
CEP-RCP 53 CPC40M 122 CSG960D 36 F12DKBG5B 61 R162S24 114
CEP-SS 53 CPC50M 122 CSG960G 36 F12DPCG5C 62 R162T24 115
CH-B12.5 128 CPC60M 122 CSL120C 24 F150TDS84C 56 R41E24 97
CH-C 128 CPC64M 122 CSL240C 25 F16DKCG5B 61 R41EAD 98
CH-C10 128 CPD25F 120 CSL481C 26 F16DPCG5C 62 R41S24F 116
CH-C22.5 128 CPD25M 120 CSL85C 23 F16TDVST2 55 R41U24F 99
CH-C32.5 128 CPD37F 120 CSR50U 49 F16TYT8 59 R42E24 100
CH-CA 128 CPD37M 120 CSU0120S 45 F180TDS84C 56 R42EAD 101
CH-S 128 CPD50F 120 CSU240S 46 F200TDDS84C 57 R42S24 114
CI-NPN/PNP 84 CPD50M 120 CS-UPS1 44 F20DKCG5B 61 R42T24 115
CK/S 129 CR4-1 103 CS-UPS2 44 F20DPCG5C 62 R81E24 97
CKB 129 CR4-2SC 104 CSW121B 28 F20TYS9 60 R81EAD 98
CKBG 129 CR8-1 103 CSW121C 28 F25TYT8 59 R81S24F 116
CKBX2 129 CR8-3 105 CSW241B 29 F300TDSS84C 58 R81U24F 99
CK-PCB 129 CRE4-1 103 CSW241C 29 F30DKCS5B 61 R82E24 100
CKR16 94 CRE4-2SC 104 CSW241DP 29 F30DPGS5C 62 R82EAD 101
CKR25 94 CRE8-1 103 CSW241G 29 F30TDVST2 55 R82S24 114
CKS024DC024DC03 110 CRE8-3 105 CSW481C 30 F36TYT8 59 R82T24 115
CKS024DC024DC05 110 CSA120BC 39 CSW481D 30 F400TDSS84C 58 RE1024D 86
CKS024DC024DC10 110 CSA120CB 39 CSW481G 30 F42TDVST2 55 RE1824D 86
CKS024DC230AC05 111 CSA120CC 39 CSW960CP 31 F50TYT8 59 RE2024D 87
CKS1S 113 CSA120DC 39 CWAA7-0530 70 F55TDVST2 55 RF1024D 86
CL1R 41 CSA240FC 40 CWAA7-0531 70 F75TDVST2 55 RF1824D 86
CL5R 41 CSBC 43 CWAA7-0532 70 IF10PML 120 RFA024D 86
CLP08CC 127 CSBD 48 CWAA7-0533 71 IF14PML 121 RMP081CM 102
CLP16CC 127 CSC120B 47 CWAA7-0534 71 IF16PML 121 SW50VA 81
CLT08AC 126 CSC120C 47 CWAA7-0535 71 IF20PML 121 WAA7-0540 80
CLT08CC 126 CSD15B 11 CWAA7-0536 72 IF26PML 121 WAA7-0541 80
CLT16AC 126 CSD15C 11 CWAA7-0537 72 IF34PML 121 WAA7-0542 80
CLT16CC 126 CSD30C 12 CWAA7-0538 72 IF40PML 121
135
Index by Catalogue number
CODE PAGE CODE PAGE CODE PAGE CODE PAGE CODE PAGE
PTCCK42 130 XCDM08CC 125 XCMB16B 131 XCSG481C 33 XF75TDVST2 55
X756340 75 XCDM08CS 124 XCMB27B 131 XCSG500C 34 XIF10PML 120
X756360 74 XCDM16AC 125 XCOP082 117 XCSG500G 34 XIF14PML 121
X756370 76 XCDM16CC 125 XCPC20M 122 XCSG720C 35 XIF16PML 121
X756516 68 XCDM16CS 124 XCPC26M 122 XCSG720D 35 XIF20PML 121
X756524 82 XCDM24AC 125 XCPC34M 122 XCSG960C 36 XIF26PML 121
X756526 73 XCDM24CC 125 XCPC40M 122 XCSG960D 36 XIF34PML 121
X756527 73 XCDM24CS 124 XCPC50M 122 XCSG960G 36 XIF40PML 121
X756530 70 XCEPBCB 53 XCPC60M 122 XCSL120C 24 XISD09FM 119
X756531 70 XCEPBCR 53 XCPC64M 122 XCSL240C 25 XISD09PF 119
X756532 70 XCEPD1 53 XCPD25F 120 XCSL481C 26 XISD09PM 119
X756533 71 XCEPD2 53 XCPD25M 120 XCSL85C 23 XISD15FM 119
X756534 71 XCEPMTW 53 XCPD37F 120 XCSR50U 49 XISD15PF 119
X756535 71 XCEPRCC 53 XCPD37M 120 XCSU0120S 45 XISD15PM 119
X756536 72 XCEPRCP 53 XCPD50F 120 XCSU240S 46 XISD25FM 119
X756537 72 XCEPSS 53 XCPD50M 120 XCSUPS1 44 XISD25PF 119
X756538 72 XCKB 129 XCR41 103 XCSUPS2 44 XISD25PM 119
X756539 69 XCKBG 129 XCR42SC 104 XCSW121B 28 XISD37FM 119
X756540 80 XCKPT 129 XCR81 103 XCSW121C 28 XISD37PF 119
X756541 80 XCKR16 94 XCR83 105 XCSW241B 29 XISD37PM 119
X756542 80 XCKR25 94 XCRE41 103 XCSW241C 29 XMBC2K 51
X756816 77 XCKS 129 XCRE42SC 104 XCSW241DP 29 XNPNPNP 84
X756844 78 XCKS024DC024DC03 110 XCRE81 103 XCSW241G 29 XO332060 107
X756894 74 XCKS024DC024DC05 110 XCRE83 105 XCSW481C 30 XO332240 107
X766082 113 XCKS024DC024DC10 110 XCSA120BC 39 XCSW481D 30 XR041E24 97
X766083 112 XCKS024DC230AC05 111 XCSA120CB 39 XCSW481G 30 XR041EAD 98
X766184 83 XCKS1S 113 XCSA120CC 39 XCSW960CP 31 XR041S24F 116
X766802 130 XCKX2 129 XCSA120DC 39 XF03DKBG5B 61 XR041U24F 99
X766803 130 XCL1R 41 XCSA240FC 40 XF03DPCG5C 62 XR042E24 100
X766804 130 XCL5R 41 XCSBC 43 XF06DKBG5B 61 XR042EAD 101
X766813 130 XCLP08CC 127 XCSBD 48 XF06DPCG5C 62 XR042S24 114
X766842 95 XCLP16CC 127 XCSC120B 47 XF07TDVST2 55 XR042T24 115
X766845 95 XCLT08AC 126 XCSC120C 47 XF100TDVST2 55 XR081E24 97
X766846 95 XCLT08CC 126 XCSD15B 11 XF100TYT8 59 XR081EAD 98
X766847 95 XCLT16AC 126 XCSD15C 11 XF10TYG9 60 XR081S24F 116
X766848 95 XCLT16CC 126 XCSD30C 12 XF12DKBG5B 61 XR081U24F 99
XAR6 42 XCM1A012 91 XCSD30E 12 XF12DPCG5C 62 XR082E24 100
XBB125 128 XCM1A024 91 XCSD30F 12 XF150TDS84C 56 XR082EAD 101
XBC000 128 XCM1A120 91 XCSD50B 13 XF16DKCG5B 61 XR082S24 114
XBC010 128 XCM1A230 91 XCSD70C 14 XF16DPCG5C 62 XR082T24 115
XBC225 128 XCM1C012 88 XCSF120C 18 XF16TDVST2 55 XR161E24 97
XBC325 128 XCM1C024 88 XCSF120CP 18 XF16TYT8 59 XR161EAD 98
XBCA00 128 XCM1C048 88 XCSF120DP 18 XF180TDS84C 56 XR161S24F 116
XBS000 128 XCM1C110 88 XCSF240C 19 XF200TDDS84C 57 XR161U24F 99
XCAPIPO3 67 XCM1S024 108 XCSF240CP 19 XF20DKCG5B 61 XR162E24 100
XCCIS2 79 XCM1S024E 108 XCSF240DP 19 XF20DPCG5C 62 XR162EAD 101
XCCM08CV 123 XCM1T024 109 XCSF30C 16 XF20TYS9 60 XR162S24 114
XCCM08SV 123 XCM1T024E 109 XCSF500C 20 XF25TYT8 59 XR162T24 115
XCCM16CV 123 XCM2A012 92 XCSF500D 20 XF300TDSS84C 58 XRE1024D 86
XCCM16SV 123 XCM2A024 92 XCSF565 21 XF30DKCS5B 61 XRE1824D 86
XCCM24SV 123 XCM2A120 92 XCSF85B 17 XF30DPGS5C 62 XRE2024D 87
XCDIN2 132 XCM2A230 92 XCSF85C 17 XF30TDVST2 55 XRF1024D 86
XCDIN4 132 XCM2C012 89 XCSF85CP 17 XF36TYT8 59 XRF1824D 86
XCDIN5 132 XCM2C024 89 XCSG2401C 37 XF400TDSS84C 58 XRFA024D 86
XCDINM45 132 XCM2C048 89 XCSG2401D 37 XF42TDVST2 55 XRMP081CM 102
XCDIWMP2 131 XCM2C110 89 XCSG2401G 38 XF50TYT8 59 XW000932 81
XCDM08AC 125 XCM4C024 90 XCSG2401R 38 XF55TDVST2 55
136
ELECTRONIC PRODUCTS PRODUCTS AND SYSTEMS PHOTOVOLTAIC SYSTEMS INDUSTRIAL MARKING
FOR ELECTRICAL PANELS FOR THE CONNECTION CONNECTION AND SYSTEMS
OF ELECTRICAL PANELS PROTECTION