NetSure™ 8100DB Series

Distribution Bay

Key Features The high capacity, modular NetSure™ 8100DB delivers


effective secondary load distribution with increased visibility
yy High capacity up to 4,800 amp
(eight panel) or 3600 amp and detailed understanding of all loads in your core facility.
(six panel) continuous rating
with an interrupting capacity of
10,000 amps Description Application
yy Each panel is configured for The NetSure 8100DB distribution bay
up to 800 amp feed, delivering features high capacity, modularity, and The NetSure 8100DB Series is designed
a continuous rating of 640 amps simplified installation. These features for centralized power applications where
yy Enhanced meter panel with full provide effective secondary load secondary distribution is needed. These
color display distribution and protection for multiple bays are ideal for colocation and core
-48 VDC feeds up to 640 amps (800 facilities including cable headends,
yy Optional individual current
measurement enables you to amps 20% derated) . Equipped with an MTSOs and MSOs. They are also well
configure and monitor each load advanced controller from Vertiv, optional suited for applications requiring effective
down to the distribution/fuse/ secondary load distribution and
breaker level Intelligent Load Management (ILM)
enables you to visualize load location, protection of power plants up to 640 amp
yy Communication via 10/100Mbit power performance, and distribution capacity per load.
Ethernet (standard), as well as
inefficiencies in order to optimize the
most common protocols including Additional Information
SNMPv2, SNMPv3, Modbus DC power system, control cooling, and
avoid overload. For additional specification, engineering
yy Modular design with
interchangeable fuse and circuit The NetSure 8100DB consists of a and installation information request
breaker distribution modules SAG582140600
Zone 4 welded framework, with either six
yy TPS, TLS and TPL fuses protect or eight panels and top or bottom feed/
circuits ranging from 3 amps to distribution. Each panel holds up to 168
250 amps
fuse or circuit breaker positions per bay.
yy Circuit breaker protection with Each bay may be configured for 2, 4, 6 or
plug-in bullet breakers available 8 busses. A wide variety of options are
in current ratings of 1 amp to
300 amps available including, internal ground bars
with a paralleling feature that permits
yy NEBS level 3 compliance, meets or
exceeds all relevant GR1089,
multiple panels to be tied together, and
GR63 and UL specifications transient voltage surge suppression. The
universal return bars can be mounted to
yy Security encryption options for
TCP/IP, HTTPS, SSL/SSH overhead framing or a cable rack.

yy Three ground return options The bay is now available in

-- Overhead bus bars 7' H x 30" W x 16" D


(2.13 m x 76.2 cm x 38.1 cm)
-- Internal panels
or a larger option:
-- Internal full bay: 1200 A
standard; 2400 A optional 7' H x 30" W x 24" D
(2.13 m x 76.2 cm x 60.96 cm).
yy Easy access to cables and
terminations simplifies installation
and maintenance

NetSure™ 8100DB
NetSure™ 8100DB Series

Distribution Modules 6 Panel Bay Distribution Population


The distribution modules are factory Qty./Panel Qty./Bay Type Description
configurable with one or more of
20 120 TPS/TLS 3 A to 70 A fuseholders*
the available fuseholders or circuit
10 60 TPL 70 A to 250 A fuseholders*
breakers, and can be populated
28 168 Bullet 1 A to 300 A circuit breakers
in varying combinations.
28 168 TPS/TLS 3 A to 125 A bullet fuseholders
See the “6 Panel” and “8 Panel” 0 4 GMT 1.33 amp for ABS supply**
charts to the right for options.
* Panels may be factory or field configured for either TPS or TPL fuses. Each TPL fuseholder will take the place of two
TPS fuseholders.

Extended Metering ** Fuses supplied from factory.

The meter panel provides monitoring


of two current thresholds, two voltage 8 Panel Bay Distribution Population
thresholds and a fuse alarm on each
Qty./Panel Qty./Bay Type Description
panel. The voltage and current values
12 96 TPS/TLS 3 A to 70 A fuseholders*
are now visible via the local color display.
Optional Intelligent Load Management 6 48 TPL 70 A to 250 A fuseholders*

(ILM) monitors all currents, identifying 16 128 Bullet 1 A to 300 A circuit breakers
alarms on the individual circuit breakers 16 128 TPS/TLS 3 A to 125 A bullet fuseholders
within that unit. Eight programmable 0 4 GMT 1.33 amp for ABS supply**
relays are provided that may be * Panels may be factory or field configured for either TPS or TPL fuses.
programmed to any or all of the alarm Each TPL fuseholder will take the place of two TPS fuseholders.
conditions. Alarms may be sent over ** Fuses supplied from factory.
Modbus or SNMP and thresholds are
remotely set via web pages, and all bus Options
designations are user configurable.
Option Description
Four GMT fuse positions are provided
for remote ABS loads as well as individual Single or Parallel Busses May be configured for 2, 4, 6 or 8 busses rated at 640 A continuous

GMT fuses on feeds to the meter and Adjustable Dressing Bars Sliding dressing bars for reduced output cable installation time
alarm panels, eliminating the need for Cable Management Kit Grooming kit for load cable dressing
inline fuses used in previous models. Transient Voltage Protection Bus voltage protection for sensitive electronic equipment
Options allow the bay to be ABS sourced Bottom Feed Air Block Provides insert for raised floor applications to block air flow.
internally or remotely. 2400 Amp Internal Return Bars Provides additional feeds at the opposite end and increases capacity
to 2400 A per side; comes with optional bonding strap
Factory Installed Hardware Hardware (flat. lock & nut) are factory installed on every stud
Hardware Kit Hardware provided in bulk, not installed in the factory

Vertiv controller Individual current


displays output measurement for
voltage for every each fuse/breaker
panel

Vertiv.com | Vertiv Headquarters, 1050 Dearborn Drive, Columbus, OH, 43085, USA
© 2019 Vertiv Group Corp. All rights reserved. Vertiv™ and the Vertiv logo are trademarks or registered trademarks of Vertiv Group Corp. All other names and logos referred to are trade names, trademarks or registered trademarks of their respective owners. While every
precaution has been taken to ensure accuracy and completeness here, Vertiv Group Corp. assumes no responsibility, and disclaims all liability, for damages resulting from use of this information or for any errors or omissions. Specifications, rebates and other promotional
offers are subject to change at Vertiv’s sole discretion upon notice.

DC-00019 (R9/19)

You might also like