Procentec t1 Terminator Manual en v210

The Terminator T1 provides active termination for PROFIBUS networks. It has redundant power supplies and diagnostic LEDs to monitor the status of each power source. It can be installed on a standard DIN rail and terminates the PROFIBUS segment while allowing devices to be removed or replaced without disturbing communication. The T1 has additional features such as a DB9 connector for maintenance and engineering tools and can operate at all common PROFIBUS baud rates.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
106 views2 pages

Procentec t1 Terminator Manual en v210

The Terminator T1 provides active termination for PROFIBUS networks. It has redundant power supplies and diagnostic LEDs to monitor the status of each power source. It can be installed on a standard DIN rail and terminates the PROFIBUS segment while allowing devices to be removed or replaced without disturbing communication. The T1 has additional features such as a DB9 connector for maintenance and engineering tools and can operate at all common PROFIBUS baud rates.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Introduction Power supply

The T1 Terminator provides active and reliable Parameters


termination for PROFIBUS networks which are based The power supply has to comply with the
on RS 485. By using this component it is possible to following specifications:
turn off, remove or replace devices without disturbing Voltage: 19 to 28 Vdc
the bus communication. This applies in particular to Current: Min. 65 mA
the devices at the end of the segment.
Wiring
The leads of both power connectors
The T1 has a couple of special features which makes
have to be wired as follows:
it a very useful infrastructure component; it has a
“-“ = 0 V
redundant power supply and diagnostic LEDs to
“+” = Positive Voltage
indicate the status of each power source. It is also
SH = Earth
equipped with an additional DB9 connector for
ProfiTrace or other maintenance/engineering tool.
The DB9 connector can also be used as the primary
bus connection if circumstances so dictate.

The T1 Terminator can be installed on a standard

Terminator T1 DIN-rail.

Active PROFIBUS DP
segement termination
Installation Manual

Terminator T1 Manual
Installation instructions

Version 1.3.2
February 2016
Location
The T1 Terminator can be installed everywhere in a
 All baudrates non-hazardous area that complies with IP 20 (DIN 40

 Redundant power supply 050) and the specified temperature range of -20 to
 DB9 connector for maintenance activities +60o Celsius.
 IP 20 with DIN-rail mounting


Position
The T1 Terminator can be installed in every position,
but it is recommended to install it with the green
PROFIBUS connector pointing down. In this position
it is easier to read the status display and to perform
measurements on the DB9 connector.

Mounting and dismounting


PROCENTEC BV The T1 Terminator has to be mounted on a 35 mm DIN-
Klopperman 16 rail with a minimum width of 60 mm. Fig. 1 and Fig. 2
2292 JD Wateringen illustrate how to mount and dismount the T1 on and
The Netherlands from the DIN-rail.

T: +31 (0)174 671 800 Fig. 2 Dismounting; Push-up and pull


Fig. 1 Mounting; pull-down and push
F: +31 (0)174 671 801
E: [email protected]
W: www.procentec.com
Redundancy
Both power connectors are linked 1-on-1 to the PROFIBUS Ground Clip
It is recommended to use the supplied GC-01 ground
internal power supply of the T1. If 1 power supply clip to attach the cable shield to the screw connector,
would fail, the other takes over without delay time. Screw connector as shown in figure 4, for easier shield connection and
When redundancy is not required, it is sufficient to The T1 Terminator has 1 PROFIBUS connector, this is better strain relief.
use 1 power connector. When the T1 is flipped 180 o, where the DP segment ends. It is common practise
the connectors can be used without alteration. Fig. 3 to connect the PROFIBUS cable to the green screw The Ground Clip GC-01 can be ordered separately per
illustrates the location of the power supply connectors. connector. This keeps the DB9 connector available 25pcs with order code 101-00201B
for maintenance activities.

Pin layout
Pin “A”: Green wire
Piggy back
connector for
Pin “B”: Red wire
maintenance
Power
activities Pin “SH”: Cable shielding

Piggy back connector


Fig. 4 Using the Ground Clip
The piggy back DB9 connector is connected
1-on-1 with the PROFIBUS screw connector.
Bus cable in

Fig. 3 Structure of the T1 Fig. 4 Using the Ground Clip

Diagnostic LEDs Technical Data Active PROFIBUS DP Termination T1 Technical Data Active PROFIBUS DP Termination T1
PROFIBUS cable specifications
Technical Data Active PROFIBUS DP Termination T1
Power supply specifications
Dimensions and weight
Dimensions L x W x 106 x 55 x 33 mm (without Cable lengths 1200 m at 9,6 kbps to 93,75 kbps Nominal supply 19 to 28 Vdc
OFF Blinking ON
H (mm) plugs) 1000 m at 187,5 kbps voltage
P1  Power is  Power supply  Power 400 m at 500 kbps
106 x 55 x 55 mm (with plugs)
OFF or an not stable or an supply OK. 200 m at 1,5 Mbps Current 65 mA at 24 Vdc
internal internal failure. 100 m at 3 Mbps to 12 Mbps consumption
Weight Approximately 125 g
failure. Check Check if P2 is
if P2 is on. on. Wire diameter < 2,5 mm2 Power dissipation Max. 2 W
Ambient conditions
P2  Power is  Power supply  Power
OFF or an not stable or an supply OK. Operating -20 to +60o Celsius Wire type Stranded or Solid core Redundancy Yes (Power 1 OR Power 2)
internal internal failure. temperature
failure. Check Check if P1 is Termination Powered according to IEC 61158 Power LED Power 1 OR Power 2
if P1 is on. on. Isolation class IP 20 (DIN 40 050) (390/220/390 Ohms)
Reverse polarity Yes
Protocol specifications protection

Supported DP-V0, DP- V1, DP-V2, FDL, MPI,


Wire diameter < 2,5 mm2
Protocols FMS, PROFIsafe, PROFIdrive and
any other FDL based protocol.

Transmission speed 9,6 kbps to 12 Mbps


(including 45,45 kbps)