Installation Manual Exit Device RFID
Installation Manual Exit Device RFID
Exit Device
Any use, operation or repair in contravention of this document is at your own risk.
ASSA ABLOY does not assume any responsibility for incidental or consequential
damages arising from the use of this manual.
All information and drawings in this document are the property of ASSA ABLOY.
Unauthorized use and reproduction is prohibited.
2. Dimensions
.................................................................................................6
2.1 Dimensions
............................................................................................................................
for rim version 6
2.2 Dimensions
............................................................................................................................
for rod version 7
2.2.1
................................................................................................................................................
Top strike for rod version 7
2.2.2
................................................................................................................................................
Bottom strike for rod version 7
2.3 Outside
............................................................................................................................
escutcheon 7
3. System
.................................................................................................8
components
3.1 Components
............................................................................................................................
in outside escutcheon 8
3.2 Components
............................................................................................................................
in outside escutcheon 9
3.3 Components
............................................................................................................................
in rod version of exit device 10
3.3.1
................................................................................................................................................
Components in glass bead shim kit 11
3.3.2
................................................................................................................................................
Components in rod extension kit 12
4. Installation
.................................................................................................13
4.1 To
............................................................................................................................
prepare the outside escutcheon 13
4.2 Preparing
............................................................................................................................
the battery cable in the push bar 14
4.3 To
............................................................................................................................
install the exit device, rim version 15
4.4 To
............................................................................................................................
install the exit device, rod version 17
5. To.................................................................................................18
check the installation
5.1 Mechanical
............................................................................................................................
check 18
5.2 Functional
............................................................................................................................
check 18
Appendix
.................................................................................................19
A: Outside template for card reader
Appendix
.................................................................................................20
B: Inside template for exit device
Appendix
.................................................................................................21
C: RFID 3G exit device
Exploded
............................................................................................................................
view and component list 21
RFID
............................................................................................................................
3G specific parts 21
Dimensions
............................................................................................................................
in mm (inches) 22
To mount
............................................................................................................................
the upgrade plate 22
Cable
............................................................................................................................
connection 23
To remove
............................................................................................................................
the front cover 23
Appendix
.................................................................................................24
D: Endnode kit
Parts
............................................................................................................................ 24
Appendix
.................................................................................................28
E: BLE exit device
Parts
............................................................................................................................ 28
Mounting
............................................................................................................................
procedure 29
Revision
.................................................................................................32
history
The exit device combines the electronic card lock with a push bar from Sargent.
This makes it possible to use encoded cards to control all guest and staff access to
the building, and at the same time provide a panic exit device to satisfy all safety
considerations for emergency exit. Opening the door from the inside is achieved
by simply pushing the push bar.
The exit device is suitable for wood, metal and glazed doors. It is supplied in
two versions:
rim version with latch on the side of the door; for horizontal installation
rod version with latch on top and bottom of the door; for vertical installation
There are two standard lengths for the horizontally installed push bar;
92 cm (3'') can be cut to fit other door width, min. 82 cm (3'')
122 cm (4'') can be cut to fit other door width, min. 92 cm (3'')
The exit device is designed for flush-mounting on the door; see a picture of the
escutcheon and its dimensions in Figure 4. For the rod version of the exit device,
a glass bead shim kit is available for doors with glass beads or raised molding with
a height of no more than 6 mm (¼''). See section 3.3.1 for detailed information.
The outside escutcheon set includes an LCU (lock controller unit) and an
electromechanical lock mechanism. The LCU is powered by a 4.5V or 9V
battery (9V for older installations only) that is located inside the push bar
behind the battery cover plate; see Figure 8 for rim version and Figure 9
for rod version.
The exit device is released mechanically from the inside by pushing on the bar.
The door is unlocked from the outside by using a valid key card. The LCU will
accept cards programmed in the Visionline, VingCard Vision or 2100 system.
Pos Description
A Protector plate
B Battery cable
C Lock case
D LCU; lock controller unit
Table 2: Components in outside escutcheon
Pos Description
1 Push bar
2 Lock chassis
3 Strike plate
4 Lock chassis cover
5 Outside escutcheon
6 End cap
7 Adapter plate
8 Battery cover plate
Table 3: Components in rim version of exit device
Pos Description
A Top latch chassis
B Top latch cover
C Rod guides
D Lock chassis
E Bottom latch cover
F Bottom latch chassis
G Push bar
H End cap
I Lock chassis cover
J Battery cover plate
K Outside escutcheon
L Adapter plate
Table 4: Components in rod version of exit device
Note: Since the thickness of the adapter plate is 3 mm (1/8 ''), one shim set 3 mm
(1/8 '') must always be used for rod guides, top strike chassis and bottom strike
chassis. Shim for lock chassis should not be used.
For installations of an exit device with rod, be aware when the door height exceeds
2133 mm (84''); in these cases, a rod extension kit must be used. The rod extension
kit can be ordered in the following lengths:
150 mm (6'')
300 mm (12'')
450 mm (18'')
Figure 17
Figure 18
Figure 19
Note: See section 3.2 for exploded view and component list of the exit device in
rim version.
1. Mount the lock chassis (B)
on the adapter plate with the
machine screws provided, and
make sure to pull the battery
cable through the hole in the
lock chassis.
Figure 20
Figure 22
Figure 23
9. Install the cover (D) for the lock chassis
(see Figure 24), and the cover for the end cap
(see Figure 25).
10. Make sure that the push bar releases the
lock mechanism; see section 5.1 Mechanical
check for details.
11. Load the applicable lock firmware into the
LCU using a service device with Lock Service/
Lock Service 3G (see Quick reference guide
Lock Service or Quick reference guide Lock
Service 3G).
12. Test for proper card operation; see section 5.2
Functional check for details.
Figure 24
Figure 25
Note: See section 3.3 for exploded view and component list of the exit device in rod version.
1. Mount the push bar (G) on the lock chassis (D) with the machine screws provided.
2. Connect the battery cable from the push bar to the cable from the LCU.
3. Strap the battery cable to the chassis.
Figure 26
4. Level the push bar and mount the end cap bracket (H) on the 3 mm (1/8)''
shim plate with the screws provided.
5. Mount the top latch chassis (A) on the 3 mm (1/8)'' shim plate according to
the templates delivered with the exit device.
6. Install the top strike according to the templates delivered with the exit device.
7. Mount the cover (B) for the top latch chassis with the screws provided.
8. Mount the bottom latch chassis (F) on the 3 mm (1/8)'' shim plate according to
the templates delivered with the exit device.
9. Install the bottom strike according to the templates delivered with the exit device.
10.Mount the cover (E) for the bottom latch chassis with the screws provided.
11.Install the rod guides (C).
12.Connect the battery cable to the battery and press the battery cover plate onto
the rail.
13.Hook up the battery cable inside the push bar.
14.Install the top and bottom strike plates according to the templates delivered
with the exit device.
15.Install the cover (I) for the lock chassis and the cover for the end cap.
16.Make sure that the push bar releases the lock mechanism; see section 5.1
Mechanical check for details.
17.Load the applicable lock firmware into the LCU using a service device with
Lock Service/Lock Service 3G (see Quick reference guide Lock Service or
Quick reference guide Lock Service 3G).
18.Test for proper card operation; see section 5.2 Functional check for details.
1. Check that the exit device latch goes smoothly into the strike plate
when the door is closed.
2. Check that the push bar moves freely back into position after it has
been depressed.
3. Check that when depressing the push bar, the parts inside the rail
do not inhibit the push bar from movement.
4. Check that the latch can be freely moved in and out from the
exit device chassis.
5. For rod installation: make sure that the vertical rod extension
moves freely when the push bar is depressed.
6. For rod installation: make sure that the latches in the top latch chassis
and bottom latch chassis move freely.
7. For rod installation: make sure that the exit device top latch and/or
bottom latch goes smoothly into the strike plates when the door is closed.
1. Insert a valid key card into the LCU in the outside escutcheon;
the LED will illuminate with a green flash.
2. Enter the room by depressing the handle.
Dimensions in mm (inches)
Figure A1
Dimensions in mm (inches)
Figure B1
Note: If upgrading an old exit device installation to RFID 3G, the 9V electronics is kept and 9V (6AA)
batteries are used instead.
Figure C2
Figure C4
2. Connect the cables according to Figure C5.
Note: To avoid squeezing the cables, place them
inside the upgrade plate.
Figure C5
Figure C6
Parts
If the exit device should be online (only applicable for Visionline), an endnode kit
must be mounted on the escutcheon according to the instruction Mounting of
endnode kit in this appendix. The endnode kit consists of the parts shown in
Figure D1.
Note: The endnode itself (see Figure D2) is sold separately.
Figure D1: Endnode kit for exit device: Y-cable, endnode holder and screws
Pos Description
1 Y-cable
2 Endnode holder
3 Screw, WN 1423 K25x8
Table D1: Parts included in the endnode kit
Figure D3
Figure D4
Figure D5
Figure D6
Figure D7
Figure D8
Figure D9
Figure D10
Figure D11
Figure D12
Figure D13
Parts
Pos Description
1 BLE bracket for Classic
2 Upgrade plate BLE
3 Cable assy, double endnode for Signature
4 Label
Table E1: Description of Classic BLE fixing kit
Figure E2
Figure E3
Figure E4
Figure E5
Figure E6
Figure E7
Figure E8
10. If ZigBee endnode is applicable, an endnode holder
with a ZigBee endnode in it is already mounted at
the bottom of the escutcheon (see Appendix D for
details about the endnode kit and mounting of it).
11. If the outside escutcheon should also be
equipped with a ZigBee endnode, connect
the remaining part of the double endnode
cable to the ZigBee endnode.
Note: Route the double endnode cable that
goes to the ZigBee endnode to the left, i.e.
between the jellyfish and the spacer.
Note: Make sure to drag the cable through
the hole in the endnode holder as shown in
the detail in Figure E10.
Figure E10
Date Change
March 3, 2012 Added RFID 3G incl endnode kit
July 3, 2013 New endnode and Y-cable
January 7, 2015 Added BLE
www.assaabloyhospitality.com