Series 27100, 28000 ®
Vertical DETECT-A-FIRE Units
Installation Instructions 12.01.F DESCRIPTION Table 2: Model Number 28021 DETECT-A-FIRE thermal detectors are UL Listed, UL of Canada °F °F Spacings (in feet) Color available upon request, and FM Approved detection and release RTI Setting Tolerance UL ULc FM Coding devices used in fire detection systems to activate alarms and actuate extinguishing systems. This Rate Compensated device 140 +7/-8 50 50 30 V-Fast Black combines the best features of both fixed temperature and 160 +7/-8 25 25 30 V-Fast Black rate-of-rise detectors. 190 +7/-8 50 50 30 V-Fast White ELECTRICAL RATING 210 +7/-8 25 50 30 V-Fast White Contact 225 +7/-8 25 50 30 V-Fast White Model Operation on Electrical Rating 275 +10 25 50 30 V-Fast Blue Number Temperature Rise (Resistive Only) 325 +10 50 50 30 V-Fast Red 27120 Opens +10 5.0 Amps 125 VAC 360 25 50 30 V-Fast Red 28020 (450°F Max) 450 +15 25 50 30 V-Fast Green 27121 5.0 Amps 126 VAC +15 500 50 50 30 V-Fast Orange 0.5 Amps 125 VDC Closes 600 + 20 N/A 50 30 V-Fast Orange 2.0 Amps 24 VDC 28021 + 20 1.0 Amps 48 VDC 725 N/A 50 30 V-Fast Orange *Although incandescent lamps are considered resistive, their inrush Note: For clean agents and CO2 supression systems, ceiling spacing current is 10 -15 times their steady current. Do not exceed ratings. 20ft. apart unless otherwise specified. Note: 28020 is a 2-wire device and RTI is not applicable. LOCATION Fitting Required for DETECT-A-FIRE detectors are precision temperature sensors. Hazardous Model UL, ULc Listings They must be mounted in an area (normally a ceiling) so that: Location Numbers and FM Approval 1. The detector spacing complies with both system Class 1*, Groups 27120-22 requirements and requirements of the agency having A, B, C, and D; 27121-20 Mount detector to a Class II, Groups 28020-3 suitably listed fitting in local jurisdiction. accordance with National E, F and G 28021-5 2. The thermal air path to the shell is not obstructed. Electric Code and/or local Class 1*, Groups Spacing per UL, FM, and UL of Canada is shown in Table 1 A, B, C, and D; 27120-0 authority having and 2. Distances given are for between units on smooth Class II, Groups 27121-0 jurisdiction. E, F and G ceilings. Distances from partitions or walls are half that shown. To assure that all spacing requirements are met, consult * Division 1 and 2. the authority having local jurisdiction. MOUNTING Table 1: Model Number 27120*, 27121 DETECT-A-FIRE units are not position sensitive. Horizontal and vertical detectors refer to the most common mounting °F °F Spacings (in feet) Color Toler- RTI configurations for that unit. However, each type can be Setting ance UL ULc FM Coding mounted either horizontally or vertically depending on the 140 +7/-8 50 50 25 Fast Black application and installation requirements. 160 +7/-8 25 25 25 Fast Black INSTALLATION 190 +7/-8 50 50 25 Fast White 210 +7/-8 25 50 30 V-Fast White 225 +7/-8 25 50 30 V-Fast White 275 +10 25 50 30 V-Fast Blue 325 +10 50 50 30 V-Fast Red 360 +10 25 50 30 V-Fast Red 450 +15 25 50 30 V-Fast Green 500 +15 50 50 30 V-Fast Orange 600 + 20 N/A 50 30 V-Fast Orange 725 + 20 N/A 50 30 V-Fast Orange * 27120 is a normally closed device and does not meet the requirements of NFPA-72 for use as an initiating device.
Page 1 Vertical DETECT-A-FIRE® Units 1-800-FENWAL-1 www.fenwalcontrols.com