AS-P
I/O, alarms, and users, handle scheduling and
logging, and communicate using a variety of
protocols. Because of this, most parts of the
system function autonomously and continue to run
as a whole even if communication fails or individual
SmartStruxure servers or devices go offline.
products and the range of Schneider Electric scheduled backups of associated AS-P devices to
products that communicate on the Modbus network storage for even greater levels of
protocol, such as power meters, UPS, circuit protection.
breakers, and lighting controllers.
IT friendly
Additional building protocol support AS-P communicates using the networking
AS-P also supports integration and communication standards. This makes installations easy,
with Schneider Electric supplied BMS systems and management simple, and transactions secure.
devices that use the following standards for
buildings: I/NET, MicroNet, and NETWORK 8000.
SSL Certificates
Communication between clients and the
SmartStruxure servers can be encrypted using
Secure Socket Layer (SSL 1.0, 2.0, 3.0, and TLS
1.0). The servers ship with a default self-signed
certificate. Commercial Certification Authority (CA)
server certificates are supported to lower the risk of
malicious information technology attacks. Use of
encrypted communication can be enforced for both
WorkStation and WebStation access.
Supported protocols
• IP addressing (IPv6 ready)
• TCP communications
• DHCP/DNS for rapid deployment and lookup
of addresses
• HTTP/HTTPS for Internet access through Figure: Two-piece design
firewalls, which enables remote monitoring and
Auto-addressing
control
The auto-addressing feature eliminates the need for
• NTP (Network Time Protocol) for time setting DIP switches or pressing commission
synchronization throughout the system buttons. Each module automatically knows its order
• SMTP enables sending email messages in the chain and assigns itself accordingly –
significantly reducing engineering and maintenance
• SNMP enables network supervision and time.
reception of application alarms in designated
network management tools Simple DIN-rail installation
Patented two-piece design Fasteners easily snap into a locked position for
Each module can be separated from its terminal panel installation. The fastener has a quick-release
base to allow the site to be wired prior to the feature for easy DIN-rail removal.
installation of the electronics. The patented locking
mechanism serves as handles for removing the
module from its base. All critical components have
a protective cover that permits convection cooling
to occur.
Specifications
Electrical
DC input supply power ....................................................................................................................... 10 W
DC input supply voltage ...................................................................................................................24 VDC
Environment
© 2015 Schneider Electric. All rights reserved.
Mechanical
Dimensions including terminal base ..............................90 W x 114 H x 64 D mm (3.6 W x 4.5 H x 2.5 D in.)
HTTPS ..........................Encrypted supporting SSL 1.0, 2.0, 3.0 and TLS 1.0, port configurable default 443
SMTP........................................................................................Email sending, port configurable, default 25
SNMP............................................................................................................................................version 3
...................................................................................................... Network supervision using poll and trap
.......................................................................................................Application alarm distribution using trap
Terminals
LNS
LNS version................................................................................................................................. OpenLNS
.........................................................................................................................Installed on WorkStation PC
LonMark
Resource files version .........................................................................................................................14.00
CPU
Frequency .................................................................................................................................... 500 MHz
Type ............................................................................................................................................ Dual-core
DDR3 SDRAM................................................................................................................................ 512 MB
eMMC memory ...................................................................................................................................4 GB
Memory backup ..................................................................................... Yes, battery-free, no maintenance
Part numbers
SmartX Controller – AS-P ............................................................................................. SXWASPXXX10001
© 2015 Schneider Electric. All rights reserved.
Internal configuration The I/O bus in the terminal base provides the AS-P
module with power and an address.
All serial communication ports of the AS-P module
refer to signal ground as shown in the figure below. The address value in the I/O bus is increased by
one for each terminal base. The I/O bus also
enables RS-485 communication between the I/O
module and the SmartStruxure server device.
Regulatory Notices
Federal Communications Commission CE - Compliance to European Union (EU)
FCC Rules and Regulations CFR 47, Part 15, Class A 2004/108/EC Electromagnetic Compatibility Directive
This device complies with part 15 of the FCC Rules. Operation is subject to the following This equipment complies with the rules, of the Official Journal of the European Union, for
two conditions: (1) This device may not cause harmful interference. (2) This device must governing the Self Declaration of the CE Marking for the European Union as specified in
accept any interference received, including interference that may cause undesired the above directive(s) per the provisions of the following standards: IEC/EN 61326-1
operation. Product Standard, IEC/EN 61010-1 Safety Standard.
© 2015 Schneider Electric. All rights reserved.
Industry Canada
ICES-003 WEEE - Directive of the European Union (EU)
This is a Class A digital device that meets all requirements of the Canadian Interference
This equipment and its packaging carry the waste of electrical and electronic equipment
Causing Equipment Regulations. (WEEE) label, in compliance with European Union (EU) Directive 2012/19/EU, governing
the disposal and recycling of electrical and electronic equipment in the European
Regulatory Compliance Mark (RCM) - Australian Communications and Media community.
Authority (ACMA)
This equipment complies with the requirements of the relevant ACMA standards made
under the Radiocommunications Act 1992 and the Telecommunications Act 1997. These UL 916 Listed products for the Unites States and Canada, Open Class Energy
standards are referenced in notices made under section 182 of the Radiocommunications Management Equipment. UL file E80146.
Act and 407 of the Telecommunications Act.