1 Hour Fire Rated Drywall STC-55
1 Hour Fire Rated Drywall STC-55
32
DEFLECTION HEAD TRACK MIN 5mm GAP FILL UP WITH FIRE
SEALANT
50mm x 0.50 THK FLAT STRAP 92mm X 0.60mm THK
156
AT EVERY HORIZONTAL BOARDS DEFLECTION HEAD TRACK
92
CONNECTION ON BOTTOM LAYER BOARDS BOTTOM LAYER KNAUF
FIRESHIELD 16mm THK
BOTTOM LAYER KNAUF
TOP LAYER KNAUF
32
FIRESHIELD 16mm THK
DENSESHIELD 16mm THK
TOP LAYER KNAUF STUD 92mm X 0.60mm THK
DENSESHIELD 16mm THK @ 610mm CTRS MAX.
PLAN BOTTOM LAYER KNAUF FIRESHIELD 16mm THK
TOP LAYER KNAUF DENSESHIELD 16mm THK
NTS
HEAD DETAIL 61
0m
m
MINERAL WOOL 92mm X 0.60mm THK 25mm SCREWS @ 152mm CENTER HORIZONTAL ACROSS THE BOARD JOINT
50mm THKWOOL
MINERAL 60kg/m3
MINERAL WOOL
50mm THKWOOL
MINERAL 60kg/m3
50mm THKWOOL
MINERAL 60kg/m3
DISCLAIMER: THE INFORMATION CONTAINED IN THIS DRAWING MAY ONLY BE USED IN 1 HOUR FIRE RATED WALL - STC 55 KNAUFPH-02
KNAUF GYPSUM PHILIPPINES, INC. CONJUNCTION WITH BORAL PLASTERBOARD (M) SDN BHD APPROVED
(ASTM E119-16a)
9TH FLOOR MARAJO TOWER 26TH STREET COR. 4TH AVENUE, BONIFACIO GLOBAL CITY, TAGUIG CITY 1634 PHILIPPINES
MATERIALS AND SYSTEMS AND IS SUBJECT TO CHANGE WITHOUT NOTICE.