Pump size & type / Stages : 1K1.

5x1LF-82 M3 LF /1
Based on curve no. : MIII7066V
Impeller diameter : 144 mm

Customer : TRITEN IAG Capacity : 4.0 m³/h


Item number : P45-11041 Head : 32.90 m
Service : Nutrient Supply Tank No.3 Pump Density / Specific gravity : - / 1.111
Flowserve reference : 3893835127 Pump speed : 2,900 rpm
Date : March 25, 2022 Ns / Nss (per eye) : 334 / 1,860 (US)
Test tolerance : ANSI/HI 14.6 Grade 2U
CURVES ARE APPROXIMATE, PUMP IS GUARANTEED FOR ONE SET OF CONDITIONS; CAPACITY, HEAD, AND EFFICIENCY....

Copyright © 2016 Flowserve. All rights reserved. Affinity v2.20.1


Hydraulic Datasheet

Customer : TRITEN IAG Pump / Stages : 1K1.5x1LF-82 M3 LF /1


Customer reference : Inquiry 30203-000-I-0057A-45 Centri... Based on curve no. : MIII7066V
Item number : P45-11041 Flowserve reference : 3893835127
Service : Nutrient Supply Tank No.3 Pump Date : March 25, 2022
Operating Conditions Materials / Specification
Capacity (rated/normal) : 4.0 m³/h / - Material column code : D4L
Water capacity (CQ=1.00) :- Pump specification : ASME B73.1
Total developed head : 32.90 m Other Requirements
Water head (CH=1.00) :- Hydraulic selection : No specification
NPSHa/NPSHa less margin : 10.3 m / - Construction : No specification
Maximum suction pressure : 0.5 barg Test tolerance : ANSI/HI 14.6 Grade 2U
Liquid Driver Sizing : Max Power(MCSF to EOC) using SF
Liquid type : Other Seal configuration : Single Seal
Liquid description : Nutrient
Temperature : 25 °C
Density / Specific gravity : - / 1.111
Solid Size - Actual / Limit : - / 6.350 mm
Viscosity / Vapor pressure : 1.00 cP / 0.03 bara
Performance
Hydraulic power : 0.40 kW Impeller diameter
Pump speed : 2,900 rpm Rated : 144 mm
Pump overall efficiency (CE=0.98) : 17.8 % Maximum : 208 mm
NPSH required (NPSH3) : 1.4 m Minimum : 102 mm
Rated brake power : 2.24 kW Ns / Nss (per eye) : 334 / 1,860 (US)
Minimum continuous flow :-
Maximum brake power : 2.59 kW Maximum head at rated diameter : 35.15 m
Driver power rating : 3.00 kW / 4.02 hp Flow at BEP : 6.5 m³/h
Casing working pressure : 4.3 barg Flow as % of BEP : 61.1 %
(based on shut off @ cut dia/rated SG) Efficiency at normal flow :-
Maximum allowable : 19.0 barg Impeller diameter ratio (rated/max) : 69.4 %
Hydrostatic test pressure : 28.5 barg Head rise to shut off : 6.9 %
Estimated rated seal chamber pressure : 0.7 barg Total head ratio (rated / max) / (max / rated) : 41.8 % / 239.3 %
CURVES ARE APPROXIMATE, PUMP IS GUARANTEED FOR ONE SET OF CONDITIONS; CAPACITY, HEAD, AND EFFICIENCY.
MCSF PROVIDES MECHANICAL PROTECTION ONLY. MINIMUM THERMAL FLOW MUST BE CALCULATED FOR THE SPECIFIC FLUID AND OPERATING CONDITIONS.

Copyright © 2016 Flowserve. All rights reserved. Affinity v2.20.1