05 Time Setting

This document summarizes test results for the normal consistency, time of setting, and compressive strength of hydraulic cement. It records the weights of cement, fly ash, and water used in trials to determine normal consistency. It also records the penetration resistance in millimeters at regular time intervals up to 24 hours to determine the initial and final setting times of the cement. Finally, it lists the average compressive strength in psi of cement mortar samples at ages of 3, 7, and 28 days.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
32 views1 page

05 Time Setting

This document summarizes test results for the normal consistency, time of setting, and compressive strength of hydraulic cement. It records the weights of cement, fly ash, and water used in trials to determine normal consistency. It also records the penetration resistance in millimeters at regular time intervals up to 24 hours to determine the initial and final setting times of the cement. Finally, it lists the average compressive strength in psi of cement mortar samples at ages of 3, 7, and 28 days.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 1

RMC-QC-05 Rev00 10.03.

22

RMC - QC Dept.
NORMAL CONSISTENCY, TIME SETTING & COMPRESSIVE STRENGTH OF HYDRAULIC CEMENT
ASTM C 187- 98 / C 191- 99 / C 109/C 109M-99
Material : Date Commenced :
Source / Supplier : Date Completed :
Date Delivered : Balance Reference No. :
Sample Reference No. :

I. NORMAL CONSISITENCY TRIAL


Wt. of Cement : Mixing Water Source :
Wt. of Fly Ash : Admix Brand / Type :
F.A. Used (%) : Dosage (%) :
Total Wt. : Temperature :

Trial Water (ml.) Admixture (ml.) Penetration (mm.) w/c


1
2
3

II. PENETRATION RESISTANCETime Molded (H)

Time
Penetration
No. Initial Setting min.
H min. Reading (mm.)
Final Setting min.
1 30
2 45 Remarks:
3 60
4 75
5 90
6 105
7 120
8 135
9 150 COMPRESSIVE STRENGTH OF HYDRAULIC
10 165 CEMENT C 109
11 180
12 195
13 210 Mortar Strength
14 225 psi
Days Ave.
15 240 A B
16 255 3
17 270 7
18 285 28
19 300
20 315
21 330 Remarks:
22 345
23 360
24 375
25 390
26 405

Tested by : Checked by:

Laboratory Technician Q.C Engineer

Phesco House 491-495 Quezon Avenue, Quezon City