RCD Assignment 4

1. Design a square tied column to carry service loads of 1070kN dead load and 981kN live load with an unsupported length of 2.5m. 2. Design a spiral column to carry 1070kN dead load and 980kN live load with an unsupported length of 2.2m. 3. Design a short round spirally reinforced concrete column to carry 12,000kg deadload and 24,000kg liveload.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
231 views3 pages

RCD Assignment 4

1. Design a square tied column to carry service loads of 1070kN dead load and 981kN live load with an unsupported length of 2.5m. 2. Design a spiral column to carry 1070kN dead load and 980kN live load with an unsupported length of 2.2m. 3. Design a short round spirally reinforced concrete column to carry 12,000kg deadload and 24,000kg liveload.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
You are on page 1/ 3

REINFORCED CONCRETE DESIGN ASSIGNMENT No.

1. Design an axially loaded square tied 6. Design an axially loaded square tied
column for a service dead load of column that could carry a axial ultimate
1070kN and a service Live load of 981kN load of 3178kN. Max size of aggregates
for an industrial building having an is 25mm fc’=20.7Mpa fy=276.5Mpa
unsupported length of column of 2.5m
and is braced against sideways. The 7. Design a square tied column having a
column caries no moment safe ultimate load of 1336kN that could
fc’=27.50Mpa , fy=413.5Mpa be placed at an eccentricity of 300mm
about the axis fc’=20Mpa ,fy=400Mpa.
2. Design a spiral column to carry a
deadload of 1070kN and a liveload of 8. Design a tied column subjected to axial
980kN if it has an unsupported length of load of 1422kN. The condition of the
2.2m fc’=27.50Mpa, fy=413.50Mpa the column are as follows:
column carries no moment. Unsupported length,Lu 5.0m
Effective length factor,k 0.9
3. CE board DEC. 1985 Flexural rigidity,EI 7500x N
Design a short round spirally reinforced
concrete column to carry an axial load og
12,000kg. deadload and 24,000kg
Magnification factor,delta 1.2
liveload, use fc’=280 kg/ and fy= Moment magnifying coeef.,cm 0.533
Use Phi=0.70 fc’=20.7Mpa and
4,220 kg/ , n=12, j=0.587, u=80kg/
fy=400Mpa
. Use ultimate strength design. Draw
9. CE board MAY 1999
details of designed column. A tied column is subjected to axial load
of 597kN and end Moments. The
4. Design a short tied column for a total condition of the column are as follows:
deadload of 1000kN and a liveload of Lu 5.0m
1350kN for a certain industrial building K 0.9
somewhere at Makati and also carrying a
EI 7500x
deadload moment of 20kN.m and
liveload moment of 40kN.m , fc’=30Mpa, Delta 1.2
fy=400Mpa use Pg=0.03
250kN.m(upper end)

5. Design a reinforced concrete square tied 200kN.m(lower end)


column that carries a dead axial load of
600kN and liveload of 800kN fc’=28Mpa,
fy=400Mpa Use phi=0.70 , fc’=21Mpa and
fy=414Mpa. Design the size and no. of
bars of the column.

CENG 115 Page 1


REINFORCED CONCRETE DESIGN ASSIGNMENT No. 4

10. Design a rectangular tied column. The


75.0 125.0 125.0 75.0
column length is 4.50m is to be
constructed in a frame braced against
sideways (the effective length factor k
can be taken as 1 and EI=34MN )
the column is located in a single 450.0 Pu
curvature by the ultimate factored
moment of 110kN.m at its top end and
120kN.m at its bottom end. The column
carries a factored axial load S due to
dead load of 150kN, 350kN due to live
loads. 400.0

11. Design a square tied column subjected 15. Design a reinforced concrete column
to a service axial dead load of 450kN. with a safe ultimate load of 1099kN at an
Live load of 500kN, dead load moment eccentricity of 450mm. fc’=27.6Mpa ,
135kN.m and live load moment of fy=414Mpa
150kN/m. fc’=21Mpa, and fy=415Mpa.
16. Design a tied column that can carry a
12. Design a rectangular reinforced concrete direct load of 670kN plus an 89kN shear
tied column having a max load of from the beam and has a moment from
2800kNm , fc’=21Mpa and fy=415Mpa the beam of 177kN.m this 177kN.m
eccentricity is 250mm moment includes the effect of the 89kN
shear. The frame is brace against
13. Design a rectangular tied column having sideways,k = 1.0
a moment capacity of 448kN.m(safe 670kN
ultimate moment it could carry). The
actual eccentricity of the load is acting at 177kN/m
400mm. fy=345Mpa, fc’=28Mpa.

14. Find the safe ultimate load and safe


ultimate moment of the column shown if 89kN
the actual eccentricity of the load is 4.25
acting at 450mm as shown in the figure.
Fy=345 Mpa , fc’=28Mpa
[eccentricity+#] A A

Determine also if the column is adequate


using USD method use a load factor of

CENG 115 Page 2


REINFORCED CONCRETE DESIGN ASSIGNMENT No. 4

1.8 for all loads and moments


fc’=27.58Mpa, fy=345Mpa. Assume
Ba=0.20, cm=1.0 use moment
magnification method.

17. Design a square tied column carrying the


ultimate load of 1759kN if the eccentricity
is only 150mm. fc’=27.6Mpa, fy=345Mpa

18. A reinforced tied column is carrying a


load of 1456kN at an eccentricity of
240mm. , fc’=24.14Mpa and
fy=345.58Mpa , Es=200 000Mpa

19. A short circular column carries a service


axial deadload of 800kN, axial live load
of 400kN and a service deadload and
live load moment of 120kN.m and
95kN.m respectively. Use fc’=28Mpa and
fy=415Mpa.