RCD Assignment 4
RCD Assignment 4
1. Design an axially loaded square tied 6. Design an axially loaded square tied
column for a service dead load of column that could carry a axial ultimate
1070kN and a service Live load of 981kN load of 3178kN. Max size of aggregates
for an industrial building having an is 25mm fc’=20.7Mpa fy=276.5Mpa
unsupported length of column of 2.5m
and is braced against sideways. The 7. Design a square tied column having a
column caries no moment safe ultimate load of 1336kN that could
fc’=27.50Mpa , fy=413.5Mpa be placed at an eccentricity of 300mm
about the axis fc’=20Mpa ,fy=400Mpa.
2. Design a spiral column to carry a
deadload of 1070kN and a liveload of 8. Design a tied column subjected to axial
980kN if it has an unsupported length of load of 1422kN. The condition of the
2.2m fc’=27.50Mpa, fy=413.50Mpa the column are as follows:
column carries no moment. Unsupported length,Lu 5.0m
Effective length factor,k 0.9
3. CE board DEC. 1985 Flexural rigidity,EI 7500x N
Design a short round spirally reinforced
concrete column to carry an axial load og
12,000kg. deadload and 24,000kg
Magnification factor,delta 1.2
liveload, use fc’=280 kg/ and fy= Moment magnifying coeef.,cm 0.533
Use Phi=0.70 fc’=20.7Mpa and
4,220 kg/ , n=12, j=0.587, u=80kg/
fy=400Mpa
. Use ultimate strength design. Draw
9. CE board MAY 1999
details of designed column. A tied column is subjected to axial load
of 597kN and end Moments. The
4. Design a short tied column for a total condition of the column are as follows:
deadload of 1000kN and a liveload of Lu 5.0m
1350kN for a certain industrial building K 0.9
somewhere at Makati and also carrying a
EI 7500x
deadload moment of 20kN.m and
liveload moment of 40kN.m , fc’=30Mpa, Delta 1.2
fy=400Mpa use Pg=0.03
250kN.m(upper end)
11. Design a square tied column subjected 15. Design a reinforced concrete column
to a service axial dead load of 450kN. with a safe ultimate load of 1099kN at an
Live load of 500kN, dead load moment eccentricity of 450mm. fc’=27.6Mpa ,
135kN.m and live load moment of fy=414Mpa
150kN/m. fc’=21Mpa, and fy=415Mpa.
16. Design a tied column that can carry a
12. Design a rectangular reinforced concrete direct load of 670kN plus an 89kN shear
tied column having a max load of from the beam and has a moment from
2800kNm , fc’=21Mpa and fy=415Mpa the beam of 177kN.m this 177kN.m
eccentricity is 250mm moment includes the effect of the 89kN
shear. The frame is brace against
13. Design a rectangular tied column having sideways,k = 1.0
a moment capacity of 448kN.m(safe 670kN
ultimate moment it could carry). The
actual eccentricity of the load is acting at 177kN/m
400mm. fy=345Mpa, fc’=28Mpa.