5404

2/2-way Solenoid Valve with


servo-piston for higher pressures

• Solenoid valve with servo-piston


• Pressure range up to 725 PSI
• Push-over solenoid system
• Adjustable switching times for DN 20 to 25

Type 5404 can be combined with... • Approvals: FM

Type 2508 Type 1078 Type 2511 Type 8600


Cable plug Timer unit ASI cable plug Dosing control

This pilot-controlled solenoid valve with servo-


Technical data
piston is closed without power and is suitable
Orifice 7/16" – 1" (DN 12 – 25 mm)
for the control of liquid and gaseous media
at high pressures. A minimum differential Body material Brass
pressure of 14.5 PSI (1 bar) is required to fully Valve internals Stainless steel, brass
open the valve. The closing time for DN 20 and
Seal material NBR, PTFE seat seal
25 can be continuously adjusted.
Media Neutral media, compressed air, water, hydraulic oil
Media temperature 14°F to 194°F (-10°C to +90°C)
Circuit function A Ambient temperature Max. 131°F (+55°C)
Voltage tolerance ±10%

2/2-way valve, normally Duty cycle 100% continuous rating


closed by spring force Electrical connection Tag connector according to DIN EN 175301-803
(previously DIN 43650) Form A (see Ordering chart for accessory
on page 4)

Protection class IP 65 with cable plug


Circuit function B
Installation As required, preferably with actuator upright
B
2/2-way valve, direct-
Response times
acting, normally open
P Opening [ms] 20-400
(on request) Closing [ms] 100-1500 (depending on orifice and differential pressure)

Power consumption
Inrush Hold (hot coil)
AC [VA] AC [VA/W] DC [W]
24 14/8 8

www.burkert–usa.com p. /4
5404

Materials

13 1 Valve body Brass


12 2 Seal (seat) PTFE
14 3 Piston Brass
11
10 4 Piston-seal PTFE
9 5 O-rings NBR
6 Cover Brass
8
7 Spring 1.4310 Stainless Steel
7 8 Plunger Seal NBR (FKM optional)
5 6
4 9 Spring 1.4310 Stainless Steel
3 10 Plunger 1.4105 Stainless Steel
11 Armature guide tube: 1.4303 Stainless Steel
2 12 Stopper 1.4105 Stainless Steel
13 Coil Polyamide
14 Cable plug Polyamide
1

Ordering chart for valves (other versions on request)


Brass body, with cable plug (please see footnote and/or Accessories)

CSA/FM/CE

recognized/
valves [PSI]
connection

14.5 – 725
frequency

UL listed/
approved

approved
range for
Pressure

Voltage/

versions
function

CV value

Item no.

Item no.

Item no.
CSA/CE
Orifice
Circuit

[V/Hz]
[GPM]
water
[mm]

Non-
Port

NPT

PSI
UL
A 2/2-way 12 NPT 1/2 2.3 14.5 - 362 024/DC 457 858 456 938 US06505
valve NC 024/60 457 859 456 939 US09326
120/60 457 860 456 940 US05795
240/60 457 861 456 941 US09327
20 NPT 3/4 5.8 14.5 - 362 024/DC 457 862 456 942 –
024/60 457 863 456 943 –
120/60 457 864 456 944 –
240/60 457 865 456 945 –
25 NPT 1 11.7 14.5 - 362 024/DC 457 866 456 946 –
024/60 457 867 456 947 –
120/60 457 868 456 948 –
240/60 457 869 456 949 –

Note: the pressure values for liquid media are shown on the rating plate! Circuit function NO (B) on request.

Note: UL listed valves include Type 2509 1/2" conduit plug. All other valves include Type 2508 series standard cable plug.

p. /4
5404

Dimensions [mm]

DN 12 mm
32mm*

A
B
5.8

15
D

A/F
46
E
F
L Cable plug DIN EN 175301-803
(previosly DIN 43650), form A
(0-250 V AC/DC) (not included)

DN 20/25 mm
A

B
D

A/F
F
L E
* explosion proofed version, 40mm

Variable dimensions [mm]


Type 2509
0.71 Port connection D Orifice A B F E L A/F
[mm]
NPT 1/2 12.0 83.00 96.5 14.0 32 65 27
2
1.28

1.10

0.71

NPT 3/4 20.0 93.0 109.0 16.0 60 100 32


3

NPT 1 25.0 99.5 119.0 18.0 70 115 41


1

2.32
1.28

NPT 1/2

ø 1.02
0.04

M3
Torque 0.74 ft-lb
0.17

1.10

* Included with allcircuitry


without UL listed valves

p. /4
5404

i Further versions on request


Circuit function Material
Circuit function NO (B) Seal: FKM
Approvals
UL, UR, CSA, Hazardous Locations Expl. proof, EEx m/ed

Ordering chart for accessories


Cable plug Type 2508 according to DIN EN 175301-803 Form A

Fixing screw

frequency
Voltage /
Circuitry

Item no.
Flat seal

None (standard) 0 - 250 V AC/DC 008 376


The delivery of a cable plug includes the flat
with LED 12 - 24 V AC/DC 008 360
seal and the fixing screw. For other cable
with LED and varistor 12 - 24 V AC/DC 008 367
plug versions acc. to DIN EN 175301-803
with rectifier, LED and varistor 12 - 24 V AC/DC 008 363
Form A (previously DIN 43650), see separate
with LED 200 - 240 V 008 362 datasheet Type 2508.
with LED and varistor 200 - 240 V 008 369
further versions see datasheet Type 2508

To find your nearest Burkert facility, click on the orange box ➞ www.burkert-usa.com

In case of special application conditions, We reserve the right to make technical changes without notice.
please consult for advice. © Christian Bürkert GmbH & Co. KG 0802/3_US-en_1000082562