Design of Shell and Tube Heat Exchanger

The document summarizes the design of a shell and tube heat exchanger. It provides specifications for the hot and cold fluids, which are an ethylene stream and water. It calculates the heat transfer area as 13 square meters based on a heat duty of 158536.78 kW. The design includes 23 tubes of 0.0190 meters outer diameter and 4.5 meters length in a shell of 0.3874 meters diameter with 0.00635 meters tube clearance. Pressure drops of 13 psi and 18 psi are calculated for the shell and tube sides, respectively.

Uploaded by

Iqra Safdar
Copyright
© © All Rights Reserved
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
100% found this document useful (2 votes)
327 views

Design of Shell and Tube Heat Exchanger

The document summarizes the design of a shell and tube heat exchanger. It provides specifications for the hot and cold fluids, which are an ethylene stream and water. It calculates the heat transfer area as 13 square meters based on a heat duty of 158536.78 kW. The design includes 23 tubes of 0.0190 meters outer diameter and 4.5 meters length in a shell of 0.3874 meters diameter with 0.00635 meters tube clearance. Pressure drops of 13 psi and 18 psi are calculated for the shell and tube sides, respectively.

Uploaded by

Iqra Safdar
Copyright
© © All Rights Reserved
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 4

Design of Shell and Tube heat exchanger

mass flowrate of hot stream=3280.919 ton/hr = 911kg/sec = 2.59×10 5 kmol/hr


Compsition:
mass fraction
ethylene 0.871
hydrogen 0.096
1-Hexene 0.034

For cooling media water was used from 25 to 40 ᵒC .

Thermophysical properties

Hot Fluid
.76273kg/
Density ρ( Kg/m3)
m3
Viscosity μ (Kg/Ms) 0.0152219

Thermal
k (W/Mk) 0.1502
Conductivity

Specific Cp(Kj/Kmol
39.35
Heat K)
Fouling
Rd 0.00035
Factor
Inlet Temp ᵒC 126
Outlet Temp ᵒC 70

Cold Fluid
Density ρ( Kg/m3) 1000
Viscosity μ (Kg/Ms) 0.8904
Thermal
k (W/Mk) 0.611
Conductivity
Specific Heat Cp(Kj/Kmol K) 72.84
Fouling Factor Rd 0.0002
Inlet Temp ᵒC 25
Outlet Temp ᵒC 40
Duty of heat exchanger

Qh = mh cp ∆ T
Qh = 570732400 kJ/hr = 158536.778 kW
Qh =QC
QC =mC Cp ∆ T
QC
mC =
Cp ∆T
mC = 522361.706 kmol/hr

Calculations

T 1 −T 2
R=
t 1 −t 2
R=¿3.7333
t 2− t 1
S=
T 1 −t 1
S=¿.1486
ft =.96
∆T 1−∆T 2
∆ Tm=
∆T1
ln
∆T2
∆ Tm=¿ 63.3
Corrected ∆ Tm=¿ 60.7

Heat Transfer Area

Lets asuume U= 200 W/m2 K


Q
AHT =
U ∗ ∆ Tm
AHT =13m2

Design specification:

shell side tube side


0.0190
shell dia Ds (m) 0.3874 outer dia d0(m)
5
tube clearence ct (m) 0.00635 length of tube Lt (m) 4.5
baffle spacing B (m) 0.1 inside dia di (m) 0.0157
tube BWG 0.0016
tube pitch Pt(m) 0.0245
thickness (m) 5
Outer surface area of single tube

aST = π doL
aST =.269m2

Theorattical number of plates


Aht
Nt=
ast
Nt=¿93

Number of passes
NP= 4
Nt
n=
Np
n=23

Equivalent diameter
2
2 do
4(Pt − π )
4
D h=
π do
DH=.021m
Shell side Tube Side

 Flow Area
aS =ct B DS/PT aT =n π di2/4
aS =.00968m2
aT= .00445 m2
 Mass Velocity
GS= ms/as GT= mT/aT
GS= 26913.88 kg/sec GT=204806 kg/sec

 Linear Velocity
uS= qs /as ut= qt /at
qs = 2.16 m3/sec qt = 1194.9 m3 / sec
uS= 223 m/s ut = 268516.5 m/ sec

 Reynold’s Number
Res =DH GS/ μS ReT =ρt ut di / μt
Res = 6365 Ret =210173

 Prandtl’s Number
Prs = cps μS / ks   Prt = cpt μt / kt
Prs = 106 Prt =5.73

 Nusselt’s Number
Nus= .36 Res.55Prs.33 Nut= .027Ret.8Prt.3
Nus = 207. Nut =825.88

 Film Coefficient

hOS=NuS ks /DH hOT=NuT kT /di


hOS=603.7 W/m2 K hOT = 552 W/m2 k

 Overall Heat transfer Co-efficiet

1
Udo=
1 di di
+ Ros+ Rot +
hos do do hot

Udo= 282.2 W/m2 K

 Pressure Drop Calculation

Friction factor from D K Q Kern

fS = .00029 (Fig 29 page # 839) fT = .00038 (Fig 26 page #836)


2 2
fs Gs Ds( Nb+1)
∆ Ps = ∆ PT ¿ f t ¿ L Np
2 g ρ s Dℎ 2 g ρ t di

∆ Ps = 8946.81 kgf / m2 ∆ PT = 12655.229kgf / m2


∆ Ps = 13 psi ∆ PT = 18 pisa
∆ Ps = .89 bar ∆ PT = 1.24 bar