0% found this document useful (0 votes)
27 views

Two Channel Temperature Indicator

This document provides information about a temperature indicator device. It includes: 1. Safety cautions and features of the device. 2. Identification of the front and back parts. 3. Procedures for operation, including starting up the device and adjusting settings. 4. Technical specifications covering electrical, mechanical, and protection aspects. 5. Details for panel cutout and ordering information.

Uploaded by

mohamedmosallam
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
27 views

Two Channel Temperature Indicator

This document provides information about a temperature indicator device. It includes: 1. Safety cautions and features of the device. 2. Identification of the front and back parts. 3. Procedures for operation, including starting up the device and adjusting settings. 4. Technical specifications covering electrical, mechanical, and protection aspects. 5. Details for panel cutout and ordering information.

Uploaded by

mohamedmosallam
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 7

‫المتـطورة لتكنولوجيا الطاقـة الجـديدة والتحـكم‬

A dvanced G E reen nergy & C


ontrol

Temperautre Indicator

M A N U A L

02/26230107 :‫ تليفاكش‬- ‫أ ش القدس الشريف – النزهة الجديدة – القاهرة‬


12A Block - Al-Quds Al Sharif St. – Alnozha Algadeda – Cairo – Egypt – Tel/Fax: 02-26230107
Website: www.agec-eg.com E-mail: [email protected]

Page 1 of 7
‫المتـطورة لتكنولوجيا الطاقـة الجـديدة والتحـكم‬
A dvanced G E
reen nergy & C
ontrol

Index

Content Page
1. Safety cautions 3
2. Features 3
3. Device identification 4
3.1 Front 4
3.2 Back 4
4. Operation procedures 5
4.1 Start up 5
4.2 Settings 5
5. Technical Specifications 7
5.1 Electrical Specifications 7
5.2 Mechanical Specifications 7
5.3 Protection Specifications 7
6. Panel Cutout 7
7. Ordering information 7

Page 2 of 7
‫المتـطورة لتكنولوجيا الطاقـة الجـديدة والتحـكم‬
A dvanced G E
reen nergy & C
ontrol

For your safety, please read the following before using.


1. Safety Cautions
Warning
1. It must be mounted on Panel.
It may give an electric shock.
2. Do not connect terminals while power on.
It may give an electric shock.
3. Do not disassemble and modify this unit. If it is necessary please
contact us.
It may give an electric shock and cause fire.
4. Please check the terminals numbers when connecting power lines.
It may cause fire.
5. When cleaning the unit, do not use water or an oil-based detergent.
It may cause an electric shock or fire and so the unit will be damaged.
6. Please connect properly after checking the polarity.
It may cause fire.

2. Features:

1- Measure and display the temperature of 2 channel (4-20mA).


2- Adjust the low and high values.
3- All setting stored in EEPROM.
4- Seven segment display
5- Parameter adjust via keypad

Page 3 of 7
‫المتـطورة لتكنولوجيا الطاقـة الجـديدة والتحـكم‬
A dvanced G E
reen nergy & C
ontrol

3. Device identification
3.1. Front

1


2
6 
3 4
5

1 Seven segment to show temperature measurement for Ch.1.


2 Seven segment to show temperature measurement for Ch.2.
3 Down arrow key (decrease parameter value in edition mode).
4 Up arrow key (increase parameter value in edition mode).
5 Ok key (store parameter value and enter in edition mode).

3.2. Back
1
2
3
4

+ - + -
4-20 mA 4-20 mA
THI-D-03 CH 1 CH 2
85-265VAC
80-250 VDC

+ -
5
6

1 Negative of Ch.2 input 4-20mA.


2 Positive of Ch.2 input 4-20mA.
3 Negative of Ch.1 input 4-20mA.
4 Positive of Ch.1 input 4-20mA.
5 Positive of power supply in case of DC supply or Line in AC.
6 Negative of power supply in case of DC supply or neutral in AC.
.
Page 4 of 7
‫المتـطورة لتكنولوجيا الطاقـة الجـديدة والتحـكم‬
A dvanced G E
reen nergy & C
ontrol

4. Operations Procedures:
4.1 Start up :
First when connect power to the indicator the display will show the
following:


Then



4.2 Settings :
We need to adjust the scaling parameters so we will go to “edition
mode” by pressing Ok key for 3 sec until the screen show



Then



 To increase the low value of input ch. 1 press up arrow key
 To decrease the low value of input ch. 1 press down arrow key
 To store settings press Ok key the display will show



Page 5 of 7
‫المتـطورة لتكنولوجيا الطاقـة الجـديدة والتحـكم‬
A dvanced G E
reen nergy & Control

Then



 To go to the next parameter press Ok key



 Do the previous steps for all parameters
 Parameters list:
Parameter Default Min Max Pattern
Low value of ch. 1 0 0  
High value of ch. 1 150 0 150 
Low value of ch. 2 0 0  
High value of ch. 2 150 0 150 
 After adjust all parameters, the display will show:



 To load default settings, switch off the indicator, press Ok key
then switch on the indicator and still press Ok key.




Page 6 of 7
‫المتـطورة لتكنولوجيا الطاقـة الجـديدة والتحـكم‬
A dvanced G E
reen nergy & C
ontrol

5. Technical Specifications:
5.1 Electrical Specifications:
Inputs:
Power supply range : 85 -265 VAC or 80-250 VDC
Signal current range : 4-20 mA

5.2 Mechanical Specifications:


Dimension : 9.6 cm * 9.6 cm * 11.2 cm

5.3 Protection Specifications


Temperature : +5oC to +60oC
Enclosure IP : IP 45
 The enclosure is isolated according to standard EN 60439-1
specification.
 The enclosure is protected against external mechanical shocks.

92±1
6. Panel Cutout

92±1

(Unit: mm)

7. Ordering information
THI - -

Temperature indicator A : Analog Version


D : Digital