FANUC PROGRAM TRANSF ER TOOL

OPERATOR'S MANUAL

B-64344EN/02
• No part of this manual may be reproduced in any form.
• All specifications and designs are subject to change without notice.

The products in this manual are controlled based on Japan's "Foreign Exchange and
Foreign Trade Law". The export from Japan may be subject to an export license by the
government of Japan.
Further, re-export to another country may be subject to the license of the government of
the country from where the product is re-exported. Furthermore, the product may also be
controlled by re-export regulations of the United States government.
Should you wish to export or re-export these products, please contact FANUC for advice.

In this manual we have tried as much as possible to describe all the various matters.
However, we cannot describe all the matters which must not be done, or which cannot be
done, because there are so many possibilities.
Therefore, matters which are not especially described as possible in this manual should be
regarded as "impossible".

This manual contains the program names or device names of other companies, some of
which are registered trademarks of respective owners. However, these names are not
followed by  or  in the main body.
B-64344EN/02 SAFETY PRECAUTIONS

SAFETY PRECAUTIONS
This "SAFETY PRECAUTIONS" section describes the precautions
which must be observed to ensure safety when using machines
equipped with the Program Transfer Tool and a FANUC CNC. Users
are requested to read "SAFETY PRECAUTIONS" carefully before
using functions described in this manual. Users should also read the
relevant descriptions in the Operator's Manual to become fully familiar
with the functions to be used.

Contents

DEFINITION OF WARNING, CAUTION, AND NOTE ................s-2


GENERAL WARNINGS AND CAUTIONS....................................s-3
WARNINGS AND NOTES RELATING TO THE PROGRAM
TRANSFER TOOL ...........................................................................s-5

s-1
SAFETY PRECAUTIONS B-64344EN/02

DEFINITION OF WARNING, CAUTION, AND NOTE

This manual includes safety precautions for protecting the user and
preventing damage to the machine. Precautions are classified into
Warnings and Cautions according to their bearing on safety. Also,
supplementary information is described as Notes. Read the Warnings,
Cautions, and Notes thoroughly before attempting to use the
machine.

WARNING
Applied when there is a danger of the user being
injured or when there is a danger of both the user
being injured and the equipment being damaged if
the approved procedure is not observed.

CAUTION
Applied when there is a danger of the equipment
being damaged, if the approved procedure is not
observed.

NOTE
Notes is used to indicate supplementary information
other than Warnings and Cautions.

- Read this manual carefully, and store it in a safe place.

s-2
B-64344EN/02 SAFETY PRECAUTIONS

GENERAL WARNINGS AND CAUTIONS

WARNING
1 Before operating the machine, thoroughly check the
entered data. Operating the machine with incorrectly
specified data may result in the machine behaving
unexpectedly, possibly causing damage to the
workpiece and/or machine itself, or injury to the user.
2 Never attempt to machine a workpiece without first
checking the programmed value, compensation
value, current position, and external signal settings.
Also, never attempt to machine a workpiece without
first checking the operation of the machine. Before
starting a production run, ensure that the machine is
operating correctly by performing a trial run using, for
example, the single block, feedrate override, or
machine lock function, or by operating the machine
with neither a tool nor workpiece mounted. Failure to
confirm the correct operation of the machine may
result in the machine behaving unexpectedly, possibly
causing damage to the workpiece and/or machine
itself, or injury to the user.
3 Ensure that the specified feedrate is appropriate for
the intended operation. Generally, for each machine,
there is a maximum allowable feedrate. The
appropriate feedrate varies with the intended
operation. Refer to the manual provided with the
machine to determine the maximum allowable
feedrate. If a machine is run at other than the correct
speed, it may behave unexpectedly, possibly causing
damage to the workpiece and/or machine itself, or
injury to the user.
4 When using a tool compensation function, thoroughly
check the direction and amount of compensation.
Operating the machine with incorrectly specified data
may result in the machine behaving unexpectedly,
possibly causing damage to the workpiece and/or
machine itself, or injury to the user.
5 The parameters for the CNC and PMC are factory-set.
Usually, there is no need to change them. When,
however, there is no alternative other than to change
a parameter, ensure that you fully Failure to set a
parameter correctly may result in the machine
behaving unexpectedly, possibly causing damage to
the workpiece and/or machine itself, or injury to the
user.

s-3
SAFETY PRECAUTIONS B-64344EN/02

CAUTION
1 Immediately after switching on the power, do not
touch any of the keys on the MDI panel until the
position display or alarm screen appears on the CNC
unit.
Some of the keys on the MDI panel are dedicated to
maintenance or other special operations. Pressing
any of these keys may place the CNC unit in other
than its normal state. Starting the machine in this
state may cause it to behave unexpectedly.
2 The operator's manual for Program Transfer Tool
describes all the basic functions of the CNC,
including the optional functions. The selected
optional functions vary with the machine. Some
functions described in this manual may not,
therefore, be supported by your machine. Check the
machine specifications before using Program
Transfer Tool.
3 Some machine operations and screen functions are
implemented by the machine tool builder. For an
explanation of their usage and related notes, refer to
the manual provided by the machine tool builder.
For example:
- On some machines, executing a tool function
causes the tool change unit to operate. When
executing a tool function on such a machine,
stand well clear of the tool change unit.
Otherwise, there is a danger of injury to the
operator.
- Many auxiliary functions trigger physical
operations, such as rotation of the spindle. Before
attempting to use an auxiliary function, therefore,
ensure that you are fully aware of the operation to
be triggered by that function.

NOTE
Command programs, parameters, and variables are
stored in nonvolatile memory in the CNC. Generally,
the contents of memory are not lost by a power on/off
operation. However, the contents of memory may be
erased by mistake, or important data in nonvolatile
memory may have to be erased upon recovering
from a failure.
To enable the restoration of data as soon as possible
if such a situation arises, always make a backup of
the data in advance.

s-4
B-64344EN/02 SAFETY PRECAUTIONS

WARNINGS AND NOTES RELATING TO THE PROGRAM TRANSFER


TOOL
Warnings and notes relating to the Program Transfer Tool are described
below and also in the chapters in this manual. Before using the Program
Transfer Tool, read this manual thoroughly and be familiar with the
contents of the warnings, cautions, and notes.

WARNING
1 When using a program on an actual CNC machine,
ensure that the machine and tool controlled by the
program instructions operate safely before starting
to operate the machine.
If an incorrect program is used for a reason, or if a
program is used incorrectly, the machine or tool may
operate unpredictably, possibly causing damage to
the tool, machine, or workpiece, or a danger of the
user being seriously injured.
2 This software transfers programs to a CNC
machine, but the software does not check whether
these programs operate on the CNC machine
properly. When using a program on an actual CNC
machine, therefore, observe the instructions
described in warning 1 above.
3 When even a program that has run normally on an
actual CNC machine is used repeatedly, the
contents of the program input to the CNC machine
may change because of degradation of the storage
medium of the program or change in communication
environment if the program is transferred by a
communication function. Therefore, when using a
program on the actual CNC machine, observe the
instructions described in warning 1 above.

In this manual, programs for giving CNC machines


instructions to operate are referred to as programs.
In manuals of CNC machines, these programs are
sometimes called machining programs, part
programs, or programs. When these terms have the
same meanings and purposes as the term
"program" used in this manual, be sure to observe
the warnings described above.

s-5
SAFETY PRECAUTIONS B-64344EN/02

Exclusive control for files

NOTE
Be careful not to attempt to perform more than one
operation such as downloading, uploading, editing,
copying, movement, and deletion for one program
at the same time.

Downloading to the program memory and Series 30i/ 31i /32i DATA SERVER

NOTE
O numbers and file names stored in the program
memory or DATA SERVER are not file names on
the personal computer but are O numbers and file
names written in files.
It is recommended that the write protection
parameter of the CNC be set to prevent
unpredictable overwriting.

Downloading of data other than programs

NOTE
When tool offsets, custom macros, and workpiece
origin offsets are downloaded, values in the CNC
are changed.

s-6
B-64344EN/02 TABLE OF CONTENTS

TABLE OF CONTENTS
SAFETY PRECAUTIONS............................................................................s-1
DEFINITION OF WARNING, CAUTION, AND NOTE ............................................. s-2
GENERAL WARNINGS AND CAUTIONS............................................................... s-3
WARNINGS AND NOTES RELATING TO THE PROGRAM TRANSFER TOOL ... s-5

I. GENERAL
1 OUTLINE OF THIS MANUAL ................................................................. 3
2 FUNCTION OVERVIEW .......................................................................... 9
2.1 CONNECTION TO A CNC .......................................................................... 10
2.2 PROGRAM TRANSFER TO AND FROM THE PROGRAM MEMORY ....... 10
2.3 PROGRAM TRANSFER TO AND FROM A DATA SERVER ...................... 11
2.4 OPERATION ON FILES ON THE PC.......................................................... 11
3 OPERATING ENVIRONMENT .............................................................. 12
3.1 CNC............................................................................................................. 13
3.2 PERSONAL COMPUTER/HARDWARE ...................................................... 17
3.3 PERSONAL COMPUTER/SOFTWARE ...................................................... 18

II. INSTALLATION
1 INSTALLATION .................................................................................... 23
1.1 PREPARATION ........................................................................................... 24
1.2 INSTALLATION ........................................................................................... 24
1.3 UPGRADE INSTALLATION......................................................................... 28
2 UNINSTALLATION ............................................................................... 32

III. SETTING
1 SETTING ............................................................................................... 39
1.1 SERIAL NUMBER ....................................................................................... 41
1.2 MACHINE INFO.TAB................................................................................... 42
1.3 SETTING COMMUNICATION WITH PROGRAM MEMORY ...................... 44
1.3.1 Confirming Communication Settings.....................................................................46
1.4 SETTING COMMUNICATION WITH DATA SERVER................................. 50
1.4.1 Confirming Communication Settings.....................................................................52
1.5 DISPLAY ..................................................................................................... 57
1.6 MAINTENANCE OF SETTINGS.................................................................. 59
1.7 MENU .......................................................................................................... 60

c-1
TABLE OF CONTENTS B-64344EN/02

IV. OPERATION
1 OPERATION ......................................................................................... 63
1.1 STARTING THE TOOL................................................................................ 64
1.2 SCREEN CONFIGURATION OF THE PROGRAM TRANSFER TOOL ...... 64
1.2.1 Menu and Toolbar ..................................................................................................65
1.2.2 Display of the Upper Screen (PC Information) ......................................................66
1.2.3 Display of the Lower Screen (Connection Destination Information).....................67
1.3 PC FILE LIST OPERATION ........................................................................ 68
1.3.1 Changing the Display of the PC Side Current Management Folder.......................68
1.3.1.1 Changing the method of display ........................................................................ 69
1.3.1.2 Changing the order of display............................................................................ 70
1.3.1.3 Updating the display .......................................................................................... 70
1.3.2 Operating Files and Folders on the PC...................................................................71
1.3.2.1 Viewing a file .................................................................................................... 71
1.3.2.2 Editing a file ...................................................................................................... 72
1.3.2.3 Copying a file .................................................................................................... 72
1.3.2.4 Moving a file ..................................................................................................... 73
1.3.2.5 Deleting a file or folder...................................................................................... 75
1.3.2.6 Renaming a file or folder ................................................................................... 76
1.3.2.7 Creating a new folder......................................................................................... 76
1.4 FILE TRANSFER TO AND FROM THE PROGRAM MEMORY .................. 77
1.4.1 Display of a List of Programs in the Program Memory .........................................77
1.4.1.1 Changing the method of display ........................................................................ 81
1.4.1.2 Changing the order of display............................................................................ 81
1.4.1.3 Changing the path of the CNC under communication....................................... 82
1.4.2 File Transfer to and from the Program Memory ....................................................83
1.4.2.1 Uploading from the program memory to the PC ............................................... 83
1.4.2.2 Downloading from the PC to the program memory .......................................... 87
1.4.3 Operating Files and Folders in the Program Memory ............................................92
1.4.3.1 Deleting a file or folder...................................................................................... 92
1.4.3.2 Renaming a file or folder ................................................................................... 93
1.4.3.3 Creating a new folder......................................................................................... 94
1.5 TRANSFER OF DATA OTHER THAN PROGRAMS................................... 95
1.5.1 Display of a Data List.............................................................................................96
1.5.1.1 Changing the method of display ........................................................................ 98
1.5.2 Uploading from the CNC to the PC .......................................................................99
1.5.3 Downloading from the PC to the CNC.................................................................101
1.6 FILE TRANSFER TO AND FROM THE DATA SERVER........................... 103
1.6.1 Display of a List of Files on the Data Server .......................................................103
1.6.1.1 Changing the method of display ...................................................................... 105
1.6.1.2 Changing the order of display.......................................................................... 105
1.6.2 File Transfer to and from the Data Server............................................................106
1.6.2.1 Uploading from the data server to the PC........................................................ 106
1.6.2.2 Downloading from the PC to the data server................................................... 110
1.6.3 Operating Files and Folders on the Data Server...................................................116
1.6.3.1 Deleting a file or folder.................................................................................... 116
1.6.3.2 Renaming a file or folder ................................................................................. 117
1.6.3.3 Creating a new folder....................................................................................... 117
1.7 SETTING OF OPTIONS ............................................................................ 118
1.7.1 Listing Tab ...........................................................................................................118
1.7.2 View, Edit Tab .....................................................................................................119

c-2
B-64344EN/02 TABLE OF CONTENTS

1.7.3 Communication Tab .............................................................................................120

APPENDIX
A SETTING OF THE CNC ...................................................................... 123
B Windows Firewall Settings ............................................................... 126
B.1 In Case of Using Windows 2000 Service Pack 4 ....................................... 127
B.2 In Case of Using Windows XP Service Pack 2 .......................................... 127
B.3 In Case of Using Windows Vista................................................................ 133

c-3
I. GENERAL
B-63344EN/01 GENERAL 1.OUTLINE OF THIS MANUAL

1 OUTLINE OF THIS MANUAL


This manual applies to the Program Transfer Tool edition 3.0.
This chapter provides an outline of this manual.

Organization
This manual is outlined below.

SAFETY PRECAUTIONS
This part describes notes that the user needs to bear in mind
when reading this manual.

I. GENERAL
This part outlines this manual.

II. INSTALLATION
This part describes how to install the Program Transfer Tool.
Be sure to read this part before installing the tool.

III. SETTING
This part describes the settings to be made for using the
individual functions.

IV. OPERATION
This part describes how to operate each screen.

APPENDIX
This part describes the settings to be made for the CNC or
Windows OS.

-3-
1.OUTLINE OF THIS MANUAL GENERAL B-63344EN/01

Related manuals
The table below lists manuals related to this manual.
When using this manual, refer to the manuals listed below as well.

Related manuals of Ethernet board


Specification
Manual name
number
Fast Ethernet / Fast Data Server For Series 30i-A
B-64014EN
OPERATOR'S MANUAL
Fast Ethernet Board / Fast Data Server
B-63644EN
OPERATOR'S MANUAL
Ethernet Board / Data Server Board
B-63354EN
OPERATOR'S MANUAL

Related manuals of FANUC Series 30i/300i, 31i/310i, 32i/320i -A


Specification
Manual name
number
DESCRIPTIONS B-63942EN
CONNECTION MANUAL (HARDWARE) B-63943EN
CONNECTION MANUAL (FUNCTION) B-63943EN-1
USER'S MANUAL
B-63944EN
(Common to Lathe System/Machining Center System)
USER'S MANUAL (For Lathe System) B-63944EN-1
USER'S MANUAL (For Machining Center System) B-63944EN-2
MAINTENANCE MANUAL B-63945EN
PARAMETER MANUAL B-63950EN

Related manuals of FANUC Series 16i/160i, 18i/180i, 21i/210i -A


Specification
Manual name
number
DESCRIPTIONS B-63002EN
CONNECTION MANUAL (HARDWARE) B-63003EN
CONNECTION MANUAL (FUNCTION) B-63003EN-1
Series 16i/18i/160i/180i/160is/180is –TA B-63004EN
OPERATOR’S MANUAL
Series 16i/18i/160i/180i/160is/180is –MA B-63014EN
OPERATOR’S MANUAL
Series 21i/210i/210is –TA OPERATOR’S MANUAL B-63084EN
Series 21i/210i/210is –MA OPERATOR’S MANUAL B-63094EN
MAINTENANCE MANUAL B-63005EN
Series 16i/18i/160i/180i/160is/180is –A B-63010EN
PARAMETER MANUAL
Series 21i/210i/210is –A PARAMETER MANUAL B-63090EN

-4-
B-63344EN/01 GENERAL 1.OUTLINE OF THIS MANUAL

Related manuals of FANUC Series 16i/160i, 18i/180i, 21i/210i -B


Specification
Manual name
number
DESCRIPTIONS B-63522EN
CONNECTION MANUAL (HARDWARE) B-63523EN
CONNECTION MANUAL (FUNCTION) B-63523EN-1
Series 16i/18i/160i/180i –TB OPERATOR’S MANUAL B-63524EN
Series 16i/160i/160is–MB, Series 18i/180i/180is –MB5, B-63534EN
Series 18i/180i/180is –MB OPERATOR’S MANUAL
Series 21i/210i –TB OPERATOR’S MANUAL B-63604EN
Series 21i/210i –MB OPERATOR’S MANUAL B-63614EN
MAINTENANCE MANUAL B-63525EN
Series 16i/18i/160i/180i/160is/180is –B B-63530EN
PARAMETER MANUAL
Series 21i/210i –B PARAMETER MANUAL B-63610EN

Related manuals of FANUC Series 0i -B


Specification
Manual name
number
DESCRIPTIONS B-63832EN
CONNECTION MANUAL (HARDWARE) B-63833EN
CONNECTION MANUAL (FUNCTION) B-63833EN-1
Series 0i–TB OPERATOR’S MANUAL B-63834EN
Series 0i–MB OPERATOR’S MANUAL B-63844EN
MAINTENANCE MANUAL B-63835EN
PARAMETER MANUAL B-63840EN

Related manuals of FANUC Series 0i -C


Specification
Manual name
number
DESCRIPTIONS B-64112EN
CONNECTION MANUAL (HARDWARE) B-64113EN
CONNECTION MANUAL (FUNCTION) B-64113EN-1
Series 0i–TC OPERATOR’S MANUAL B-64114EN
Series 0i–MC OPERATOR’S MANUAL B-64124EN
Series 0i–TTC OPERATOR’S MANUAL B-64284EN
MAINTENANCE MANUAL B-64115EN
PARAMETER MANUAL B-64120EN

Related manuals of FANUC Series 0i -D


Specification
Manual name
number
DESCRIPTIONS B-64302EN
CONNECTION MANUAL (HARDWARE) B-64303EN
CONNECTION MANUAL (FUNCTION) B-64303EN-1
USER'S MANUAL B-64304EN
(Common to Lathe System/Machining Center System)
USER'S MANUAL (For Lathe System) B-64304EN-1
USER'S MANUAL (For Machining Center System) B-64304EN-2
START-UP MANUAL B-64304EN-3
MAINTENANCE MANUAL B-64305EN
PARAMETER MANUAL B-64310EN

-5-
1.OUTLINE OF THIS MANUAL GENERAL B-63344EN/01

Related manuals of FANUC Series 20i -B


Specification
Manual name
number
DESCRIPTIONS B-63522EN
CONNECTION MANUAL (HARDWARE) B-64193EN
CONNECTION MANUAL (FUNCTION) B-63523EN-1
OPERATOR'S MANUAL B-64204EN
MAINTENANCE MANUAL B-64195EN
PARAMETER MANUAL B-64200EN

Related manuals of FANUC Power Mate i -D/H


Specification
Manual name
number
DESCRIPTIONS B-63172EN
CONNECTION MANUAL (HARDWARE) B-63173EN
CONNECTION MANUAL (FUNCTION) B-63173EN-1
OPERATOR'S MANUAL B-63174EN
MAINTENANCE MANUAL B-63175EN
PARAMETER MANUAL B-63180EN

-6-
B-63344EN/01 GENERAL 1.OUTLINE OF THIS MANUAL

License agreement
The terms and conditions set forth by FANUC must be agreed upon
by a costumer who purchases the Program Transfer Tool.

These terms and conditions represent the license agreement between


the customer and FANUC LTD. (referred to as FANUC) related to
the software product (referred to as the software) purchased by the
customer.

Article 1 Licensing of right for use


FANUC grants the customer the following right related to the
software:
<1> The software may be used on one computer.
<2> When the software is used on multiple computers, the
customer shall obtain licenses for the software as many as the
number of computers even if the software is not used at the
same time on those computers.
<3> When the software is read through the network to the
temporary memory of each computer, the customer shall
obtain license for the software as many as the number of
computers used.
<4> Only one copy of the software may be produced for backup.

Article 2 Copyright
FANUC possesses the copyright of the software. Accordingly, the
customer shall not copy the software for any purpose except for the
purpose stipulated in Article 1, "Licensing of right for use".

Article 3 Restrictions
The customer shall not transfer, lend, sell, distribute, lease, or rent
the software to a third party.

Article 4 Warranty
If the distributed media or manual of the software contains a
physical defect, and the customer so notifies FANUC within ninety
days after the reception of the software, FANUC replaces the
defective item with a new one at no cost.

Article 5 Exemption
FANUC does not provide any warranty and guarantee related to the
software except the warrant stipulated in Article 4, "Warranty".
Namely, FANUC is not liable for any direct or indirect damages
arising from the use of the software.

-7-
1.OUTLINE OF THIS MANUAL GENERAL B-63344EN/01

Abbreviations
In this manual, the following abbreviations may be used:

Abbreviations used in this manual


Term Abbreviation
Personal computer PC
Operating system OS

-8-
B-63344EN/01 GENERAL 2.FUNCTION OVERVIEW

2 FUNCTION OVERVIEW
The Program Transfer Tool is a software tool running on a personal
program (PC) to input programs to and output them from CNC
memory or a data server. The CNC and PC are connected via
Ethernet.

NOTE
The available functions vary depending on the
Ethernet device and options of the CNC. See
Chapter 3, "OPERATING ENVIRONMENT".
The functions of this tool are outlined below.

-9-
2.FUNCTION OVERVIEW GENERAL B-63344EN/01

2.1 CONNECTION TO A CNC


To connect the tool to CNCs, an Ethernet is required.
Settings for communication with up to 255 CNCs are made in advance.
One of these CNCs is selected on the operation screen to perform
program transfer.

2.2 PROGRAM TRANSFER TO AND FROM THE PROGRAM


MEMORY
The following operations can be performed on the program memory
of the CNC:
(1) Downloading a program from the PC to the program memory
(2) Uploading a program from the program memory to the PC
(3) Displaying a list of programs stored in the program memory on
the screen
(4) Deleting a program in the program memory
(5) Displaying a list of tool offsets, custom macro common variables,
and workpiece origin offset data, which can be transferred
between the PC and CNC
(6) Transferring tool offsets, custom macro common variables, and
workpiece origin offsets between the PC and CNC.
When such data is uploaded, the format of the data is the same as
the format used when the data is output from the CNC to an
external device.

NOTE
When tool offsets, custom macro common variables,
and workpiece origin offsets are downloaded from
the PC to CNC, they replace data in the CNC.

When the tool communicates with the Series 30i/31i/32i, the


following processing can also be performed:
(1) Downloading a folder and its subfolders and files from the PC to
the program memory
(2) Uploading a folder and its subfolders and files from the program
memory to the PC
(3) Deleting a folder in the program memory
(4) Renaming a file or folder in the program memory
(5) Creating a new folder in the program memory

- 10 -
B-63344EN/01 GENERAL 2.FUNCTION OVERVIEW

2.3 PROGRAM TRANSFER TO AND FROM A DATA SERVER

The following operations can be performed on external storage


devices (compact flash memory and hard disk drive) of a data
server:

(1) Downloading a file from the PC to the connection destination


(2) Downloading a folder and its subfolders and files from the PC to
the connection destination
(3) Uploading a file from the connection destination to the PC
(4) Uploading a folder and its subfolders and files from the
connection destination to the PC.
(5) Displaying lists of folders and files stored in the connection
destination
(6) Deleting a file or a folder in the connection destination
(7) Renaming a file or folder in the connection destination
(8) Creating a new folder in the connection destination

2.4 OPERATION ON FILES ON THE PC

The following operations can be performed on files and folders on


the PC:

(1) Displaying a folder tree and a file list


(2) Viewing and editing text files. The user can select a viewer for
viewing such files and an editor for editing them.
(3) Copying, moving deleting and renaming a file
(4) Creating, deleting, and renaming a folder

- 11 -
3.OPERATING ENVIRONMENT GENERAL B-63344EN/01

3 OPERATING ENVIRONMENT
This chapter explains the operating environment required for using
this tool.

Ethernet devices and CNC options


The following lists the Ethernet devices and CNC options required for
transferring files and non-program data to and from program memory
and a data server:
CNC option required for
CNC option required for
transferring files and
transferring files and
CNC type Ethernet device used non-program data to and
non-program data to and from
from data server (FTP
program memory
server setting required)
Embedded Ethernet No option required (*1) (Communication not enabled)
Series 30i /31i /32i -A
Fast Data Server board Ethernet functions Data Server functions
Embedded Ethernet No option required (*1) (Communication not enabled)
Ethernet board
(Communication not enabled)
Series 16i /18i /21i -B Fast Ethernet board
Ethernet functions
Data Server board
Data Server functions
Fast Data Server board
Ethernet board
Ethernet functions (Communication not enabled)
Fast Ethernet board
Series 16i /18i /21i -A Extended driver and libraries
Data Server board
function Data Server functions
Fast Data Server board
Embedded Ethernet No option required (Communication not enabled)
Series 0i -D
Fast Data Server board Ethernet functions Data Server functions
Fast Ethernet board (Communication not enabled)
Series 0i -C Ethernet functions
Fast Data Server board Data Server functions
Fast Ethernet board (Communication not enabled)
Series 0i -B Built-in I/O board with Ethernet functions
Data Server functions
data server
Embedded Ethernet No option required (*1)
Series 20i -B (Communication not enabled)
Fast Ethernet board Ethernet functions
Ethernet functions
Ethernet board
Power Mate i -D/H Extended driver and libraries (Communication not enabled)
Fast Ethernet board
function
*1 To use the embedded Ethernet function in the Series 32i-A,
Series 21i-B, and Series 20i-B, specify the main CPU board
with the embedded Ethernet function. No option is required
on the CNC side.

NOTE
1 For details of Ethernet devices, see Section 3.1, "CNC".
2 The PCMCIA LAN card is not supported.
- 12 -
B-63344EN/01 GENERAL 3.OPERATING ENVIRONMENT

3.1 CNC

Ethernet board or data server board and CNC options


The following table lists the Ethernet boards and data server boards
that can be used with this tool and necessary CNC options.

Ethernet board or data server board and required CNC options (1/3)
Applicable
No Name Drawing number CNC option Control software
model
FS 16i /18i /21i A02B-XXXX-S707 *1
1 Ethernet board for A02B-0236-J292
-TA/MA A02B-0207-J800 *2
LCD-mounted type
FS 16i /18i /21i
2 CNC A02B-0281-J292 A02B-XXXX-S707 *1
-TB/MB
A02B-XXXX-S707 *1
FS 16i /18i /21i
3 ATA data server board A02B-0236-J145 A02B-0207-J800 *2
-TA/MA
for LCD-mounted type A02B-XXXX-S737 *3
CNC FS 16i /18i /21i A02B-XXXX-S707 *1
4 A02B-0281-J145
-TB/MB A02B-XXXX-S737 *3
FS 16i /18i /21i A02B-XXXX-S707 *1
5 A02B-0265-J291
Ethernet board for -TA/MA A02B-0207-J800 *2
stand-alone type CNC FS 16i /18i /21i A02B-0236-J561
6 A02B-0281-J298 A02B-XXXX-S707 *1
-TB/MB #6561
A02B-XXXX-S707 *1
FS 16i /18i /21i
7 ATA data server board A02B-0265-J145 A02B-0207-J800 *2
-TA/MA
for stand-alone type A02B-XXXX-S737 *3
CNC FS 16i /18i /21i A02B-XXXX-S707 *1
8 A02B-0281-J148
-TB/MB A02B-XXXX-S737 *3
A02B-XXXX-S707 *1
FS 16i /18i
9 A02B-0265-J154 A02B-0207-J800 *2
RISC+ATA data server -TA/MA
A02B-XXXX-S737 *3
board for stand-alone
A02B-0281-J158
type CNC FS 16i /18i A02B-XXXX-S707 *1
10 A02B-0281-J160
-TB/MB A02B-XXXX-S737 *3
*4
Power Mate i A02B-0259-J862 *5 A02B-0259-J561
11 Ethernet board A02B-0259-J230
-D/H A02B-0259-J847 *6 #6561
FS 16i /18i /21i A02B-XXXX-S707 *1 A02B-0281-J561
12 A02B-0236-J293
-TA/MA A02B-0207-J800 *2 #6567
FS 16i /18i /21i A02B-0281-J561
13 Fast Ethernet board for A02B-0281-J293 A02B-XXXX-S707 *1
-TB/MB #6567
LCD-mounted type
A02B-0281-J561
14 CNC FS 0i-TC/MC A02B-0281-J293 A02B-XXXX-S707 *1
#656W
A02B-0281-J561
15 FS 0i-TC/MC A02B-0309-J293 A02B-XXXX-S707 *1
#656W

- 13 -
3.OPERATING ENVIRONMENT GENERAL B-63344EN/01

Ethernet board or data server board and required CNC options (2/3)
Applicable
No Name Drawing number CNC option Control software
model
FS 16i /18i /21i A02B-XXXX-S707 *1 A02B-0281-J561
16 A02B-0265-J293
-TA/MA A02B-0207-J800 *2 #6567
Fast Ethernet board for FS 16i /18i /21i A02B-0281-J561
17 A02B-0281-J299 A02B-XXXX-S707 *1
stand-alone type CNC -TB/MB #6567
A02B-0281-J561
18 FS 0i-TB/MB A02B-0281-J299 A02B-XXXX-S707 *1
#6567
A02B-XXXX-S707 *1
FS 16i /18i /21i A02B-0281-J561
19 A02B-0236-J140 A02B-0207-J800 *2
-TA/MA #6567
ATA fast data server A02B-XXXX-S737 *3
for LCD-mounted type FS 16i /18i /21i A02B-XXXX-S707 *1 A02B-0281-J561
20 A02B-0281-J146
CNC -TB/MB A02B-XXXX-S737 *3 #6567
A02B-XXXX-S707 *1 A02B-0281-J561
21 FS 0i-TC/MC A02B-0281-J146
A02B-XXXX-S737 *3 #656W
Fast data server A02B-XXXX-S707 *1 A02B-0281-J561
22 FS 0i-TC/MC A02B-0309-J146
for FS 0i-C A02B-XXXX-S737 *3 #656W
A02B-XXXX-S707 *1
FS 16i /18i /21i A02B-0281-J561
23 ATA fast data server A02B-0265-J140 A02B-0207-J800 *2
-TA/MA #6567
for stand-alone type A02B-XXXX-S737 *3
CNC FS 16i /18i /21i A02B-XXXX-S707 *1 A02B-0281-J561
24 A02B-0281-J149
-TB/MB A02B-XXXX-S737 *3 #6567
Built-in I/O board
A02B-XXXX-S707 *1 A02B-0281-J561
25 (with data server) for FS 0i -TB/MB A02B-0299-H021
A02B-XXXX-S737 *3 #6567
stand-alone type CNC
A02B-XXXX-S707 *1
FS 16i /18i
26 A02B-0265-J157 A02B-0207-J800 *2
RISC+ATA fast data -MA
A02B-XXXX-S737 *3 A02B-0281-J561
server for stand-alone
A02B-0281-J161 #6567
type CNC FS 16i /18i A02B-XXXX-S707 *1
27 A02B-0281-J162
-MB A02B-XXXX-S737 *3
*4
Embedded Ethernet for
LCD-mounted FS 16i /18i
28 - Not required *7
type/stand-alone type -TB/MB
CNC A02B-0281-J571
Embedded Ethernet for #656A
LCD-mounted FS 21i
29 - Not required *8
type/stand-alone type -TB/MB
CNC *8

Power Mate i A02B-0259-J862 *5 A02B-0259-J555


30 Fast Ethernet board A02B-0259-J293
-D/H A02B-0259-J847 *6 #6567

Fast
A02B-XXXX-S707 A02B-0303-J561
Ethernet board for
FS 30i /31i /32i A02B-0303-J146 *10 #6569
31 LCD-mounted
-A *9 A02B-XXXX-S737 A02B-0303-J572
type/stand-alone type
*11 #656F
CNC
Embedded Ethernet for A02B-0303-J571
LCD-mounted #656E
32 FS 30i /31i -A - Not required *12
type/stand-alone type A02B-0303-J572
CNC #656F

- 14 -
B-63344EN/01 GENERAL 3.OPERATING ENVIRONMENT

Ethernet board or data server board and required CNC options (3/3)
Applicable
No Name Drawing number CNC option Control software
model
Embedded Ethernet for
LCD-mounted
33 FS 32i -A - Not required *13
type/stand-alone type
CNC *13
Embedded Ethernet A02B-0281-J571
34 FS 20i-TB/FB - Not required *14
*14 #656V

A02B-0281-J561
35 Fast Ethernet board FS 20i-TB/FB A02B-0281-J293 A02B-XXXX-S707 *1
#656W

Fast
Ethernet board for A02B-XXXX-S707 *1 A02B-0319-J561
36 FS 0i -TD/MD A02B-0319-J146
LCD-mounted type A02B-XXXX-S737 *3 #658W
CNC

*1 A02B-XXXX-S707: Ethernet function for the Series


16i/18i/21i/0i/20i
This option is required when the tool communicates with the
program memory through an Ethernet board. When only the
function for communicating with the data server is used, this
option is not required.
XXXX specifies a drawing number according to the CNC type as
follows:

CNC type 16i -TA 16i -MA 16i -TB 16i -MB 18i -TA 18i -MA 18i -TB 18i -MB
Value of XXXX 0236 0237 0281 0282 0238 0239 0283 0284

CNC type 21i -TA 21i -MA 21i -TB 21i -MB 0i -TB 0i -MB 0i -TC 0i -MC
Value of XXXX 0247 0248 0285 0286 0299 0300 0309 0310

CNC type 0i -TD 0i -MD 20i -TB 20i -FB


Value of XXXX 0319 0320 0287 0288

*2 A02B-0207-J800: Extended driver and libraries for the Series


16i/18i /21i
This option is required when Model A is used.
When Model B is used, this option is unnecessary regardless of
whether the embedded function or external board is used.

*3 A02B-XXXX-S737: Data server function


This option is required when the function for communicating
with the data server is used.
XXXX specifies a drawing number according to the CNC type.
See *1.

*4 A02B-0281-J160 is a high-speed version of A02B-0281-J158.


A02B-0281-J162 is a high-speed version of A02B-0281-J161.

*5 A02B-0259-J862: Ethernet function for the PowerMate i-D/H

- 15 -
3.OPERATING ENVIRONMENT GENERAL B-63344EN/01

*6 A02B-0259-J847: Extended driver and libraries for the


PowerMate i-D/H

*7 When the embedded Ethernet function is used with the Series


16i/18i-TB/MB, no CNC option is required.

*8 When the embedded Ethernet function is used with the Series


21i-TB/MB, the main CPU board with the embedded Ethernet
function must be specified. No CNC option is required.

*9 A02B-0303-J146: Fast Ethernet board for LCD-mounted type


and stand-alone type CNCs
This board provides the Ethernet function and/or the data server
function according to the CNC option used.

*10 A02B-XXXX-S707: Ethernet function for the Series


30i/31i/32i-A
This option is required for using the function for communicating
with programs. When only the function for communicating
with the data server is used, this option is not required. XXXX
specifies one of the following drawing numbers according to the
CNC type:
0303 (30i -A) 0307 (31i -A) 0308 (32i –A)

*11 A02B-XXXX-S737: Data server function for the Series


30i/31i/32i-A
This option is required for using the function for communicating
with the data server. XXXX specifies a drawing number
according to the CNC type. See *10.

*12 When the embedded Ethernet function is used with the Series
30i/31i-A, no CNC option is required.

*13 When the embedded Ethernet function is used with the Series
32i-A, the main CPU board with the embedded Ethernet function
must be specified. No CNC option is required.

*14 When the embedded Ethernet function is used with the Series
20i-B, the main CPU board with the embedded Ethernet function
must be specified. No CNC option is required.

- 16 -
B-63344EN/01 GENERAL 3.OPERATING ENVIRONMENT

3.2 PERSONAL COMPUTER/HARDWARE

The following hardware is required for running this tool:


Computer
IBM PC/AT compatible machine
• CPU: Pentium® 300MHz or higher is recommended.
• Physical memory: 128MB or more
• HDD: Free space of at least 30MB
• Keyboard, mouse, and CD-ROM required.
• Ethernet function required
Display
• Resolution: 1024 × 768 dots or higher
• Color: 16 colors or more

- 17 -
3.OPERATING ENVIRONMENT GENERAL B-63344EN/01

3.3 PERSONAL COMPUTER/SOFTWARE

When the OS is Windows Vista


(1) and (2) below are required:

(1) Microsoft Windows Vista® Business (32 bit version OS)


(2) Microsoft Internet Explorer 7.0 or later

NOTE
1 To do the following operations of this tool on
Windows Vista, the user must belong to the
Administrators group.
a) Installation
b) Uninstallation
c) Upgrade installation
2 This tool does not support the user switching
function of Windows Vista.

When the OS is Windows XP


(1) and (2) below are required:

(1) Microsoft Windows XP® Professional Service Pack 2 or later


(32 bit version OS)
(2) Microsoft Internet Explorer 6.0 or later

NOTE
1 To use this tool on Windows XP, the user must
belong to the Administrators group.
2 Only the user who has installed this tool can use
this tool.
This tool does not support the user switching
function of Windows XP.

When the OS is Windows 2000


(1) and (2) below are required:

(1) Microsoft Windows 2000® Professional ServicePack 4 or later


(2) Microsoft Internet Explorer 6.0 or later

NOTE
1 To use this tool on Windows 2000, the user must
belong to the Administrators group.
2 Only the user who has installed this tool can use
this tool.

- 18 -
B-63344EN/01 GENERAL 3.OPERATING ENVIRONMENT

Supported Language
English, Japanese, and Simplified Chinese

The language displayed with this tool is automatically selected


according to the language of OS when you install this tool.
English will be selected if this tool is installed in OSs other than the
language of the above.

- 19 -
II. INSTALLATION
B-63344EN/01 INSTALLATION 1.INSTALLATION

1 INSTALLATION
This chapter explains the procedure for installing the Program
Transfer Tool.

NOTE
1 The screen images used in this chapter are screen
images on the Microsoft operating system
Windows Vista Business.
2 To install and upgrade this tool, the user needs to
have the Administrator privilege.
3 In the following OS, only the user who has installed
this tool can use this tool.
- Windows XP
* This tool does not support the user switching
function.
- Windows 2000

- 23 -
1.INSTALLATION INSTALLATION B-63344EN/01

1.1 PREPARATION

This tool uses the TCP/IP protocol to communicate with a CNC via
Ethernet.
Make sure that the TCP/IP function is installed in the personal
computer in which this tool is to be installed and that the IP address
and subnet mask (and the default gateway if necessary) of the personal
computer are set.

1.2 INSTALLATION

To install this tool, use the setup program on the installation CD.

NOTE
1 To install this tool, the user must have the
Administrator privilege.
2 Before starting to install this tool, end all programs
being running.

(1) Start the computer, and set the installation CD.


When the installation CD is set, the installer is started
automatically.
Depending on the using OS and the settings on the personal
computer, it might be displayed as follows:
(a) AutoPlay dialog is displayed.
Click the "Run setup.exe".

(b) The file on the installation CD are displayed by the explore.


Start setup.exe on the installation CD.
(c) Nothing is displayed.
Start setup.exe on the installation CD with the explorer.

- 24 -
B-63344EN/01 INSTALLATION 1.INSTALLATION

(2) When the "User Account Control" screen is diplayed, click the
"Allow".
* The screen isn’t displayed depending on the using OS and the
settings on the personal computer.

(3) The installer start screen is displayed. Click the <Next> button.

- 25 -
1.INSTALLATION INSTALLATION B-63344EN/01

(4) The terms in the software license agreement are displayed. Read
the license agreement carefully. When accepting the terms in the
license agreement, select the "I accept the terms in the license
agreement" and click the <Next> button.

(5) Determine the installation folder. Check the "Install Program


Transfer Tool to". To install the tool in the indicated destination
folder, click the <Next> button. To change the destination folder,
click <Change>, select a folder, then click the <Next> button.

- 26 -
B-63344EN/01 INSTALLATION 1.INSTALLATION

(6) Click the <Install> button. Installation then starts.

(7) When installation is completed, the screen shown below is


displayed.
Click the <Finish> button to exit the installer.

This completes the installation.

NOTE
It is necessary to set the Windows Firewall to
communicate with DATA SERVER with some of
Windows OS.
Refer to the Appendix B, "Windows Firewall
Settings".

- 27 -
1.INSTALLATION INSTALLATION B-63344EN/01

1.3 UPGRADE INSTALLATION

By the upgrade installation, you can upgrade this tool without


uninstalling the old version.
After upgrading, setting items in the old version can be used as it is.

To upgrade this tool, use the setup program on the upgrade CD.

NOTE
1 The Program Transfer Tool cannot be installed
only by the upgrade CD.
2 To upgrade this tool, the user must have the
Administrator privilege.
3 Before starting to upgrade this tool, terminate all
programs being running.
4 The serial numbers of the following specification
are necessary to upgrade.
- Program Transfer Tool (A08B-9510-J513)
- Program Transfer Tool Upgrade
(A08B-9510-J514)

The procedure of the upgrade installation is different depending on the


version of the Program Transfer Tool that has already been installed.
When the version is prior to 2.0, refer to (a). When the version is 2.0
or later, refer to (b).
* You can confirm the version by selecting the [Version] in the [Help]
menu of the Program Transfer Tool Settings screen.

(a) The version of Program Transfer Tool that has already been installed is prior
to 2.0.
(1) Back up the settings of the Program Transfer Tool that has already
been installed.
About the backup procedure, refer to the "1.6 MAINTENANCE
OF SETTINGS" in the "Part III. SETTING".
NOTE
Don’t store the backup file in the folder that
have been installed the Program Transfer Tool.
This folder is removed when uninstalling.

- 28 -
B-63344EN/01 INSTALLATION 1.INSTALLATION

(2) Uninstall the Program Transfer Tool that has already been
installed.
Before uninstalling, write down the folder name where the version
1.0 is installed.
About the uninstallation procedure, refer to the "2
UNINSTALLATION".
NOTE
Uninstall from the "Uninstall a program" or the
"Add/Remove Programs" in the "Control Panel"
of Windows. Don’t uninstall by using the
installation CD.

(3) When the upgrade CD is set, the installer is started automatically.


The installer isn’t started automatically depending on the using
OS and the settings on the personal computer. Refer to the (1)
and the (2) in the "1.2 INSTALLATION", start the installer.

(4) The information on the necessary serial number is displayed.


When you continue installing, click the <Yes> button.

(5) Install the version 2.0 to the folder where the version 1.0 had
installed. The installation procedure after this is similar to the
normal installation procedure. Refer to the (3) or later in the "1.2
INSTALLATION".

(6) After the installation is completed, start the Settings screen.


Enter the serial numbers of the following specification.
- Program Transfer Tool (A08B-9510-J513)
- Program Transfer Tool Upgrade (A08B-9510-J514)

(7) Restore the settings of the Program Transfer Tool backed up on


the (1).
About the restoration procedure, refer to the "1.6
MAINTENANCE OF SETTINGS" in the "Part III. SETTING".

- 29 -
1.INSTALLATION INSTALLATION B-63344EN/01

(b) The version of the Program Transfer Tool that has already been installed is
2.0 or later.
(1) When the upgrade CD is set, the installer is started automatically.
The installer isn’t started automatically depending on the using
OS and the settings on the personal computer. Refer to the (1)
and the (2) in the "1.2 INSTALLATION", start the installer.

(2) When upgrading, click the <Yes> button.

(3) The versions of each program are displayed. To continue, click


the <Yes> button.

(4) Click the <Next> button. The upgrade installation starts.

- 30 -
B-63344EN/01 INSTALLATION 1.INSTALLATION

(5) The information on the folder where the backup is preserved is


displayed. Click the <OK> button.

(6) When the upgrade installation is completed, the screen shown


below is displayed.
Click the <Finish> button to exit the installer.

(7) Start the Settings screen, and enter the serial number of the
following specification.
- Program Transfer Tool upgrade (A08B-9510-J514)
If the serial number of the Program Transfer Tool
(A08B-9510-J513) has not been entered, it is necessary to enter
the serial number of the Program Transfer Tool too.

- 31 -
2.UNINSTALLATION INSTALLATION B-63344EN/01

2 UNINSTALLATION
This chapter explains the procedure for uninstalling the Program
Transfer Tool.
This tool is uninstalled by using one of the following two ways.
(1) <Windows Vista>
Use the "Uninstall a program" in the "Control Panel" of
Windows.
<Windows XP or Windows 2000>
Use the "Add/Remove Programs" in the "Control Panel" of
Windows.
(2) Use the installation CD.

Normally, uninstall the program by using "Add/Remove Programs" in


(1).

NOTE
1 The screen images used in this chapter are screen
images on the Microsoft operating system
Windows Vista Business.
2 To uninstall this tool, the user needs to have the
administrator privilege.
3 Before starting uninstallation, end all running
programs.

Using "Add/Remove Programs" to uninstall this tool

(1) Choose [Start] → "Control Panel" of Windows to display the


"Control Panel" screen.

(2) Click the "Uninstall a program" on the "Control Panel".

(3) From a list of installed programs, select "Program Transfer Tool",


and click [Uninstall]. The uninstaller then starts.

- 32 -
B-63344EN/01 INSTALLATION 2.UNINSTALLATION

(4) A message box appears to ask the user whether to uninstall the
tool. Click the <Yes> button.

(5) When the "User Account Control" screen is diplayed, click the
"Allow".
* The screen isn’t displayed depending on the using OS and the
settings on the personal computer.

(6) The folders that installed the Program Transfer Tool and it’s
subfolders are will be deleted. Confirme that a necessary file
such as backup files doesn't exist. When it is no problem, click
the <Yes> button.

(7) When the uninstallation is completed, the "Program Transfer


Tool" is removed from the list of the (3).

- 33 -
2.UNINSTALLATION INSTALLATION B-63344EN/01

Using the installation CD to uninstall the tool

(1) When the installation CD is set, the installer is started


automatically.
The installer isn’t started automatically depending on the using
OS and the settings on the personal computer. Refer to the (1)
and the (2) in the "1.2 INSTALLATION", start the installer.

(2) The maintenance program is started. Click the <Next> button.

(3) After selecting the [Remove], click the <Next> button.

- 34 -
B-63344EN/01 INSTALLATION 2.UNINSTALLATION

(4) The confirmation screen of the uninstallation is displayed. Click


the <Remove> button.

(5) The folders that installed the Program Transfer Tool and it’s
subfolders are will be deleted. Confirme that a necessary file
such as backup files doesn't exist. When it is no problem, click
the <Yes> button.

- 35 -
2.UNINSTALLATION INSTALLATION B-63344EN/01

(6) When the uninstallation is completed, the screen shown below


appears. Click the <Finish> button to exit the maintenance
program.

- 36 -
III. SETTING
B-63344EN/02 SETTING 1.SETTING

1 SETTING
On the setting dialog, set the machine with which this tool is to
perform data transfer.

On the setting dialog, set the following:


(1) Serial No
Enter the factory-set serial number provided together with the
installation CD. Unless the serial number is entered, settings
cannot be made on the setting dialog.
(2) Machine Info.
Set the machine name, the CNC type, and the number of paths.
(3) Program Memory
Make settings for communicating with the program memory.
(4) Data Server
Make settings for communicating with the data server.
(5) Display
Make display-related settings.

- 39 -
1.SETTING SETTING B-63344EN/02

Starting setting
Choose "Setting dialog" in the "Program Transfer Tool" group.

NOTE
It is impossible to use the Program Transfer Tool
and the setting dialog at the same time.
- Before starting setting, end the Program Transfer
Tool.
- Before using the Program Transfer Tool, end the
setting dialog.

Ending setting
Click the <Exit> button. Alternatively, click [Exit] in the [File]
menu.

Setting method
Setting items are classified by function into tabs.
Set items by following the steps below.
(1) Select a machine No.
(2) Make settings, then click the <Save> button or click [Save] in the
[File] menu.
(3) Click the <Exit> button or click [Exit] in the [File] menu to end
the screen.

To cancel the settings made so far, click the <Cancel> button.


However, settings once saved by <Save> cannot be canceled.

When the user selects another machine No. or clicks the Exit button
without clicking the Save button after making settings, a message
appears to ask the user whether to save the settings. To save the
settings, click the <OK> button.

- 40 -
B-63344EN/02 SETTING 1.SETTING

1.1 SERIAL NUMBER

To use the Program Transfer Tool, the serial number provided


together with the installation CD must be entered on the setting dialog.
Unless the serial number is entered, it is impossible to make settings.
Once the serial number is entered, it need not be entered again.

Click [Admin] in the [Serial No] menu. The "Serial No.


administration" dialog box is then displayed. Enter the serial number
provided together with the installation CD of the Program Transfer
Tool.

This figure is an example.


Please input a correct serial
number.

This figure is an example.


Registered specification
number and serial number
will be displayed.

(1) Serial No. setting


Enter a 24-digit serial number. When a lowercase letter is
entered, it is converted to the uppercase letter. An already
registered serial number cannot be entered.
(2) Registered Serial No.
Registered serial No. and specification number will be displayed.

- 41 -
1.SETTING SETTING B-63344EN/02

1.2 MACHINE INFO.TAB

Set machine information in the Machine Info. tab.


(1) Machine No
Select a machine number for which settings are to be made.
(2) Machine Name
Set a name consisting of up to 40 one-byte characters (up to 20
two-byte characters) for each machine. It is impossible to
delete a machine name or to set the same name as the name of
another existing machine. Names are case-sensitive. The
machine name set here is displayed in the machine list of the
Program Transfer Tool.
The default is "McnName_XXX", where XXX is a 3-digit
machine number.
(3) CNC Type
Select the type of the CNC.
NOTE
If the type of the CNC selected and the type of
the CNC connected are different, it is not
possible to use this tool.
(4) Control Path
Select the number of paths controlled by the CNC.

- 42 -
B-63344EN/02 SETTING 1.SETTING

Automatic setting through communication


When communication with the CNC via FOCAS2/Ethernet is enabled,
CNC Type and Control Path can also be set through communication
with the CNC. If communication with the CNC is enabled when
these items are set, automatic setting through communication should
be performed to prevent setting errors.
For details, see (9), "Set Machine Info. by Communication", in
Section 1.3, "SETTING COMMUNICATION WITH PROGRAM
MEMORY".

- 43 -
1.SETTING SETTING B-63344EN/02

1.3 SETTING COMMUNICATION WITH PROGRAM MEMORY

In the Program Memory tab, settings are made to communicate with a


program memory to transfer data other than programs.

(1) Machine No
Select a machine number for which settings are to be made.
(2) Communicate with Program Memory
When communication with the program memory is to be
performed, check this check box. This enables setting in this
tab.
If this check box is not checked, setting in this tab cannot be
performed.
(3) Ethernet Type
For communication with the program memory, select which type,
[Embedded Ethernet] or [Ethernet Board/DATA SERVER], is to
be used.
(A) When [Embedded Ethernet] is selected
The IP address used for the program memory and the IP
address used for the data server must not be set to the same
value.
(B) When [Ethernet Board/DATA SERVER] is selected
The IP address used for the program memory and the IP
address used for the data server must not be set to different
values.When [Ethernet Board/DATA SERVER] is selected,
it becomes impossible to set an IP address in the Data
Server tab, and the IP address set in the Program Memory
tab is displayed.

- 44 -
B-63344EN/02 SETTING 1.SETTING

(4) IP Address
Enter the value set as the IP address of the CNC. Up to 63
one-byte characters can be entered. This item is always
required. The value to be set must not be the same as the value
set as the IP address for another machine. A host name may
also be entered. When a host name is used, it is not case
sensitive. For the setting method for each CNC, see Appendix.
(5) TCP Port No.
Enter the value set as the TCP port number of the CNC. This
item is always required. A value from 5001 to 65535 can be
entered. The default is 8193. For the setting method for each
CNC, see Appendix.
(6) Communication timeout
Enter a timeout period in seconds to be applied during
communication. This item is always required. A value from 0
to 600 can be entered. If 0 is entered, the tool waits infinitely
without causing a timeout. The default is 10.
(7) O number digits
When connecting the tool to a CNC that can use 8-digit O
numbers, check 8 digits. The default is 4 digits.
(8) Communication setting confirmation
Correct communication with the CNC can be confirmed. After
adding or modifying settings in this tab, be sure to confirm
communication. For details, see Subsection 1.3.1, "Confirming
Communication Settings".
(9) Set Machine Info. by Communication
CNC Type and Control Path, which are entered in the Machine
Info. tab, can be set through communication with the CNC.
When this button is clicked, communication with the CNC is
performed to obtain the values of CNC Type and Control Path,
and the following message is displayed:

When the OK button is clicked, the indicated values are set.

- 45 -
1.SETTING SETTING B-63344EN/02

1.3.1 Confirming Communication Settings


When the <Communication setting confirmation> button in the
Program Memory tab is clicked, a screen for confirming
communication settings is displayed.
This subsection shows screen examples displayed when the settings
are correct and when there are setting errors and explains how to
correct these setting errors.

NOTE
The buttons on the screen are used for checking
communication problems.
In normal operation, these buttons must not be
used.

Screen display when the settings are correct


If the IP addresses of the PC and CNC are correct, and the power to
the CNC is on, a screen as shown below is displayed:

(1) "PING test..."

(2) "Get System Information test..."

- 46 -
B-63344EN/02 SETTING 1.SETTING

(1) "PING test..." shows the results of a PING command test for the
CNC.
(2) "Get System Information test..." shows CNC system information.
CNC Type: Indicates the type of the CNC.
Number: Indicates the model number of the i Series.
Example: 30 represents the Series 30 i.
PD: Power Mate i -D
PH: Power Mate i -H
M/T: Indicates the M/T type.
Series: Indicates the series number of the CNC
software with a 4-digit character string.
Version: Indicates the version number of the CNC
software with a 4-digit character string.
Max axes: Indicates the maximum number of axes that
can be controlled.
Axes: Indicates the number of controlled axes.

- 47 -
1.SETTING SETTING B-63344EN/02

Retesting on the communication confirmation screen


Retesting for confirming communication can be performed without
ending this screen and returning to the communication setting dialog,
by following the steps below:
(1) Enter the IP address of the communication destination in
[IpAddr].
(2) Click the <All Test> button.
When communication confirmation has been performed by retesting,
re-enter correct values on the communication setting dialog.

Setting error (1)

If the IP addresses of the PC and CNC are not correct, or if the power
to the CNC is off, a screen as shown below may appear:

When "Reply From ..." lines are not displayed, possible causes are as
follows:
(1) The power to the CNC is off, or there is a cable not connected.
(2) The IP address of the CNC and the setting on the setting dialog
do not match.
(3) The set CNC network address and host address are incorrect.
For the IP address, refer to the manual of the Ethernet board.

- 48 -
B-63344EN/02 SETTING 1.SETTING

Setting error (2)


If the IP addresses of the PC and the CNC are correct, and the power
to the CNC is on, but another setting error is present, a screen as
shown below may appear:

If no CNC system information is displayed following the "Get System


Information test...." line, possible causes are as follows:
(1) The set IP address is not the IP address of the CNC but the IP
address of a device such as a PC for which TCP/IP is set.
(2) The value set in "TCP Port No." of the CNC is incorrect.
(3) The CNC is provided with a data server option, and
communication parameters are correct, but there is no Ethernet
option.

If "No option (Extended driver and libraries function)" is indicated,


the extended driver and libraries option is missing in the CNC.

- 49 -
1.SETTING SETTING B-63344EN/02

1.4 SETTING COMMUNICATION WITH DATA SERVER

In the Data Server tab, settings are made to communicate with the FTP
server of a data server.

(1) Machine No
Select a machine number for which settings are to be made.
(2) Communication with Data Server
When communication with the FTP server of the data server is to
be performed, check this check box. This enables setting in this
tab.
If this check box is not checked, setting in this tab cannot be
performed.
(3) IP Address
Enter the IP address set for the CNC. Up to 63 one-byte
characters can be entered. This item is always required. The
value to be set must not be the same as the value set as the IP
address in data server communication settings for another
machine. A host name may also be entered. When a host
name is used, it is not case sensitive. For the setting method for
each CNC, see Appendix.
When communication with the program memory is enabled, and
[Ethernet Board/DATA SERVER] is selected as the Ethernet
type, the IP address entered in the Program Memory tab is used,
so no IP address can be entered in the Data Server tab.

- 50 -
B-63344EN/02 SETTING 1.SETTING

(4) User Name


Enter the user name set for the CNC. Up to 31 one-byte
characters may be entered. This item is always required. The
default is "dtsvr". For the setting method for each CNC, see
Appendix.
(5) Password
Enter the password set for the CNC. The entered characters are
indicated with asterisks (*). Up to 31 one-byte characters may
be entered. This item is always required. The default is
"dtsvr". For the setting method for each CNC, see Appendix.
(6) FTP Port No.
A value from 1 to 65535 can be entered. This item is always
required. The default is 21. Normally, use the default without
modification.
(7) Login Folder
Enter a login folder if it is specified. Up to 128 one-byte
characters may be entered. This item may be omitted.
(8) Communication setting confirmation
Correct communication with the data server can be confirmed.
After adding or modifying settings in this tab, be sure to confirm
communication. For details, see Subsection 1.4.1, "Confirming
Communication Settings".

- 51 -
1.SETTING SETTING B-63344EN/02

1.4.1 Confirming Communication Settings


When the <Communication setting confirmation> button on the data
server communication setting dialog is clicked, a screen for
confirming communication settings is displayed.
This subsection shows screen examples displayed when the settings
are correct and when there are setting errors and explains how to
correct these setting errors.

NOTE
The buttons on the screen are used for checking
communication problems.
In normal operation, these buttons must not be
used.

Screen display when the settings are correct

(1) PING test

(2) FTP Connect test

(3) FTP Directory List test

- 52 -
B-63344EN/02 SETTING 1.SETTING

When the settings are correct, (1) to (3) are all displayed. Their
meanings are as follows:
(1) "PING test" shows the results of a PING command test for the
communication destination. If the communication settings are
correct, "Reply from ..." is returned from the communication
destination as shown in the figure.
(2) "FTP Connect test" shows the results of a test of connection to
the communication destination. If the communication settings
are correct, a message indicating the current directory set after
login is displayed, such as "257 "/NCDATA" is current
directory" displayed in the last line.
(3) "FTP Directory List test" shows the results of testing the display
of the directory of the communication destination. If the
communication settings are correct, a list of folders or files in the
current folder set immediately after login is displayed.
After this test, a logout takes place.
If the data server contains neither files nor folders, the following
is displayed without displaying a file or folder list:
Name Size
------------------------------------
------------------------------------

Meanings of messages displayed by the FTP Connect test


The message displayed with a number varies depending on the
specification of the communication destination software. The
following shows the meanings of the numbers and display examples in
a data server:

No. Meaning and display example in data server


The communication destination becomes ready for accepting a new user.
220
Example: FANUC FTP server ready.
Login starts, and a password is requested.
331
Example: User name okay, need password.
Login is completed.
230
Example: User logged in, proceed.
The path name (the current directory in the test) has been changed.
257
Example: "/NCDATA" is current directory.
Login has not been performed.
530
Example: Not logged in.

Retesting on the communication confirmation screen


Retesting for confirming communication can be performed without
ending this screen and returning to the communication setting dialog,
by following the steps below:
(1) Enter the IP address of the communication destination in
[IpAddr].
(2) Enter the user name in [Username].
(3) Enter the password in [Password].
(4) Click the <Connect Test > button.
When communication confirmation has been performed by retesting,
re-enter correct values on the communication setting dialog.

- 53 -
1.SETTING SETTING B-63344EN/02

Setting error (1)


If the IP address of the communication destination is not correct, or
the power to the communication destination is off, "(1) PING test"
may appear as shown below.

When "Reply From ..." lines are not displayed, possible causes are as
follows:
(1) The power to the CNC is off, or there is a cable not connected.
(2) The IP address of the CNC and the setting on the setting dialog
do not match.
(3) The setting of CNC network address and host address are
incorrect.

- 54 -
B-63344EN/02 SETTING 1.SETTING

Setting error (2)


If the connected data server does not use the FTP server function, "(2)
FTP Connect test" may fail even when "(1) PING test" succeeds.
In this case, a message indicating that the communication destination
is ready to accept the user, such as "220 FANUC FTP Server ready",
is not displayed, but "Cannot connect ..." is displayed. Set a correct
connect destination.

If a screen as shown above is displayed, possible causes are as


follows:
(1) The FTP server setting for the data server is incorrect or is not
found.
(2) The ATA card of the data server is not present or fails, so the
FTP server function is disabled.

- 55 -
1.SETTING SETTING B-63344EN/02

Setting error (3)


If the set user name or password is incorrect, "(2) FTP Connect test"
may fail even when "(1) PING test" succeeds. In this case, a
message indicating that the communication destination is ready to
accept the user, such as "220 FANUC FTP Server ready.", is
displayed, but a message indicating that login failed, such as "530 Not
logged in.", is displayed.

If a screen as shown above is displayed, a possible cause is as follows:


(1) The user name or password is incorrect. It is necessary to enter
uppercase and lowercase letters correctly.

- 56 -
B-63344EN/02 SETTING 1.SETTING

1.5 DISPLAY

通信開始時に表示する PC フォルダ:

In the Display tab, items related to display are set:

(1) Machine No
Select a machine number for which settings are to be made.
(2) PC folder to be displayed when communication is started
Set the folder on the PC that is to be displayed in the PC file list
of the Program Transfer Tool when communication with the
machine starts. Clicking the right button displays PC folders
for selection. This item is always required. A folder name
consisting of up to 248 characters can be specified without
adding \ at the end.
(3) Extension for part program file icon
The Program Transfer Tool can display a special icon to
represent programs so that they can be distinguished from other
files.
Program icon
Set an extension to display the icon for programs. Up to 5
one-byte characters can be entered. This item may be omitted.
Example:
To display a file having file name "xxx.PRG" with the
program icon, enter the following:
"PRG"
When a program is uploaded from the program memory of CNC
except Series 30i/31i/32i to PC, the extension set here is added to
the program name automatically.
- 57 -
1.SETTING SETTING B-63344EN/02

(4) CNC device for communication startup


This item specifies whether to display a program memory list or
data server list when the Program Transfer Tool starts to
communicate with the machine.
When "Communicate with Program Memory" is checked in the
"Program Memory" tab, the <Program Memory> button becomes
valid.
When "Communicate with Data Server" is checked in the "Data
Server" tab, the <Data Server> button becomes valid.
When both buttons are valid, the user can select one of these
buttons.

- 58 -
B-63344EN/02 SETTING 1.SETTING

1.6 MAINTENANCE OF SETTINGS

When [Saving and Restoring of Settings] is chosen from the


[Maintenance] menu, the "Saving and Restoring of Settings" dialog
box is displayed. By using this dialog box, settings can be saved in
one setting file. It is also possible to restore settings by reading a
setting file.

(1) Backup
Settings are backed up in one file. Click the <Backup> button
to display the "Save As" dialog box. Specify a folder and a file
name.
(2) Restore
Backed up settings are restored. Click the <Restore> button to
display the "Open" dialog box. Settings are then read from a
specified backup file.
(3) Exit
This button ends this dialog box.

- 59 -
1.SETTING SETTING B-63344EN/02

1.7 MENU

The following menu functions are provided on the screen:

File menu
Cancel Cancels settings made by modification, and reads the
most recently saved data. The same function as the
<Cancel> button on the screen is provided.
Save Saves settings made by modification. The same
function as the <Save> button on the screen is
provided.
Exit Ends the screen.The same function as the <Exit>
button on the screen is provided.

Serial No. menu


Admin Inputs a serial number. For details, see Section 1.1,
"SERIAL NUMBER".

Maintenance menu
Saving and Backs up or restores settings. For details, see
Restoring of Section 1.6, "MAINTENANCE OF SETTINGS".
Settings

- 60 -
IV. OPERATION
B-63344EN/02 OPERATION 1.OPERATION

1 OPERATION
This chapter describes the method of operating the tool.

Chapter 1, "OPERATION", consists of the following sections:

1.1 STARTING THE TOOL ............................................................64


1.2 SCREEN CONFIGURATION OF THE PROGRAM
TRANSFER TOOL ....................................................................64
1.3 PC FILE LIST OPERATION.....................................................68
1.4 FILE TRANSFER TO AND FROM THE PROGRAM
MEMORY ..................................................................................77
1.5 TRANSFER OF DATA OTHER THAN PROGRAMS ............95
1.6 FILE TRANSFER TO AND FROM THE DATA SERVER ...103
1.7 SETTING OF OPTIONS..........................................................118

- 63 -
1.OPERATION OPERATION B-63344EN/02

1.1 STARTING THE TOOL

Starting the tool


Choose <Program Transfer Tool> from the [Program Transfer Tool]
group on the [start] menu of Windows.

NOTE
The Program Transfer Tool and setting dialog
cannot be executed at the same time.
• Terminate the Program Transfer Tool before
making a setting.
• Quit the setting dialog before using the Program
Transfer Tool.

1.2 SCREEN CONFIGURATION OF THE PROGRAM


TRANSFER TOOL

The screen of the Program Transfer Tool is shown below. The


screen is divided into an upper screen and lower screen. The upper
screen is a PC management screen, and the lower screen is a screen for
managing connection destinations such as a program memory and data
server.
Menu bar Tool bar

Management
screen of PC
PC Folder
Trees Slider

File List of PC
Vertical
split bar

File List of
Connection
Target
Machine List of
Connection
Target
Management
screen of
Connection
Target

Horizontal split bar Current management status bar Status bar

- 64 -
B-63344EN/02 OPERATION 1.OPERATION

1.2.1 Menu and Toolbar

Menu bar
The menu bar includes commands for operating the Program Transfer
Tool screen

Toolbar
The toolbar displays buttons for frequently used commands.

Vertical/Horizontal Split bar


By dragging the mouse by a desired width after placing the mouse on
the split bar between the PC folder tree or Machine List of Connection
Target and the file list or between the PC management screen and
connection destination management screen, the width and height of
each divided screen can be adjusted.

Status bar
The status bar displays the total number of files of the currently
selected file list. If a command that consumes a longer time, such as
a command for folder switching or connection processing, is executed,
a message is displayed to indicate that command processing is in
progress.

Slider
The slider is used to switch the page of the PC file list.
When the number of files of the currently selected folder exceeds the
maximum number of files displayable one one page of the file list, the
rest is displayed on subsequent pages.
The maximum number of files displayable per page of the file list can
be set to an arbitrary value ranging from 100 to 5000 on the options
screen.
If all files can be displayed on one page, the slider is not displayed.

- 65 -
1.OPERATION OPERATION B-63344EN/02

1.2.2 Display of the Upper Screen (PC Information)

PC folder tree
The PC folder tree is located in the upper-left area of the Program
Transfer Tool screen. The PC folder tree displays "My computer"
(folder on Windows). An arbitrary file or folder on "My computer"
can be downloaded to or uploaded from a connection destination.

File list
The upper-right area of the Program Transfer Tool screen displays a
PC file list. The PC file list displays the icons of the files of the
folder currently selected in the PC folder tree.
Files are displayed using the icons corresponding to types as indicated
below according to the file names and extensions.

File name and extension Icon Type


File name with an extension specified for
programs on the setting dialog (A file name Program
with no extension may be specified.)
File name for data other than programs (*1) Data

File names and extensions other than the above Other

*1 The table below indicates the file names for data other than
programs.

Custom macro Workpiece


Tool offset
variable origin offset
Series 30i/31i/32i-A
TOOLOFST.TXT MACRO.TXT EXT_WKZ.TXT
Series 0i-D
Series 16i/18i/21i-A/B
Series 0i-B/C TOOLOFST.DAT MACROVAR.DAT WORK-G54.DAT
Series 20i-B
Power Mate i-D/H TOOLOFST.DAT MACROVAR.DAT None
* The file names above are for data of the first path. For data of a
second or subsequent path, the extension "P-path-number" is
used. However, for the tenth path, the extension is "P10".
Example:
Tool offset data of the second path: TOOLOFST.P-2
Tool offset data of the tenth path: TOOLOFST.P10

NOTE
The file name of data other than programs is the
same as given when bit 0 of parameter No. 138 is
set to 1 on the CNC and data is output to a
memory card without specifying a file name.

Current management status bar


The PC side current management status bar displays the path of the
folder currently selected in the PC folder tree.

- 66 -
B-63344EN/02 OPERATION 1.OPERATION

1.2.3 Display of the Lower Screen (Connection Destination


Information)

Machine List of Connection Target


The lower-left area of the Program Transfer Tool screen displays a
Machine List of Connection Target. The Machine List of
Connection Target displays a Machine List.
The Machine List displays machines for which a communication
setting has already been made on the setting dialog.
When a machine is selected from the Machine List, communication is
performed with the machine and the list of programs at the connection
destination is read and displayed as a file list.
When a connection is made with the Series 30i/31i/32i or a data server,
a folder list is displayed in tree form.

File list
The lower-right area of the Program Transfer Tool screen displays a
connection destination file list. A list of programs read by
performing communication with a machine is displayed.

Current management status bar


The connection destination current management status bar displays
information (machine number, machine name, path number, and so
forth) about the machine currently selected in the Machine List of
Connection Target. If the selected machine is not connected, the
machine name only is displayed.

- 67 -
1.OPERATION OPERATION B-63344EN/02

1.3 PC FILE LIST OPERATION

1.3.1 Changing the Display of the PC Side Current Management


Folder
The PC side current management folder is the current operation target
folder on the PC side. A list of files is displayed.

(1) Initially, when the Program Transfer Tool screen is started, the
PC folder tree displays a list of the drives under "My computer",
and the Machine List of Connection Target displays a Machine
List.

(2) When the user clicks a folder in the PC folder tree, the folder is
selected as the PC side current management folder and the
contents of the folder are displayed in the PC file list.

- 68 -
B-63344EN/02 OPERATION 1.OPERATION

When the user clicks a machine in the Machine List of


Connection Target, the PC folder that is set for the machine and
is displayed at communication start time is selected in the PC
folder tree and the contents of the PC folder are displayed in the
PC file list.

A connection destination device can also be selected from the list


box on the left side of the toolbar.

1.3.1.1 Changing the method of display


The method of display can be changed as indicated below by choosing
from the [Upper File List] menu on the [View] menu or choosing from
the corresponding buttons on the toolbar.

Command name on Button on the


File list display method
[Upper File List] toolbar
[Large Icons] Large icon

[List] Small icon

[Details] Detailed display of the


following:
File name, file type, size
(bytes), last modification
data and time

- 69 -
1.OPERATION OPERATION B-63344EN/02

1.3.1.2 Changing the order of display


By choosing [Upper File List] then [Arrange Icons] from the [View]
menu, the user can make a selection from Sort by Name, Sort by Type,
Sort by Size, and Sort by Date (last modification date and time).

If [Details] is selected as the file list display format, a display order


selection can also be made by clicking [File Name], [Type], [Size], or
[Last Modification Date] at the top of the file list.

1.3.1.3 Updating the display


Press the [F5] function key or click the [Refresh] command on the
[View] menu.
The PC file list and connection destination file list are updated to the
latest information.

- 70 -
B-63344EN/02 OPERATION 1.OPERATION

1.3.2 Operating Files and Folders on the PC


This subsection describes the methods of operating files and folders
displayed in the PC file list. View, edit, copy, move, delete, rename,
and create (folders only) operations can be performed.

1.3.2.1 Viewing a file


A file on the PC can be viewed. A viewer for view operation can be
specified using the Options dialog box. For details, see Subsection
1.7.2, "View, Edit Tab". If no viewer is specified, the file viewer
built into the Program Transfer Tool is used.
The procedure is as follows:

(1) Click a file to be viewed in the PC file list.


(2) Perform a mouse operation or menu operation as described
below.
A) Mouse operation
Double-click a file to be viewed in the PC file list. The
viewer is started.
B) Menu operation
B-1) Click a file to be viewed in the PC file list.
B-2) Click the [View] command on the [File] menu or on
the menu displayed by right-clicking the selected file.
The viewer is displayed.

NOTE
1 [File Viewer] enables only one file to be viewed at a
time.
2 [File Viewer] is a text viewer, so that it cannot be
used to view a binary file.
3 The maximum size of a file displayable by [File
Viewer] is 32K bytes. If a file larger than 32K
bytes is viewed, the 32K-byte contents of the file
starting from the top of the file are displayed.
4 Only when [View] is selected from [Double click on
PC file list] in the [Options] dialog box, the viewer
can be started. For details, see Subsection 1.7.1,
"Listing Tab".

- 71 -
1.OPERATION OPERATION B-63344EN/02

1.3.2.2 Editing a file


A file on the PC can be edited. An editor for edit operation can be
specified using the Options dialog box. For details, see Subsection
1.7.2, "View, Edit Tab". If no editor is specified, the Notepad
available with the Windows OS is used.
The procedure is as follows:

(1) Click a file to be edited in the PC file list.


(2) Perform a mouse operation or menu operation as described
below.
A) Mouse operation
Double-click a file to be edited in the PC file list. The
editor is started.
B) Menu operation
B-1) Click a file to be edited in the PC file list.
B-2) Click the [Edit] command on the [File] menu or on the
menu displayed by right-clicking the selected file.
The editor is displayed.

NOTE
Only when [Edit] is selected from [Double click on
PC file list] in the [Options] dialog box, the editor
can be started. For details, see Subsection 1.7.1,
"Listing Tab".

1.3.2.3 Copying a file


The procedure for copying a file on the PC to another PC folder is
described below.

Copying a file by drag and drop


(1) Click a file to be copied in the PC file list.
To select multiple files, click each file while holding down the
[Ctrl] key.
(2) Drag a selected file to a desired folder in the PC folder tree or the
PC file list then drop the file while holding down the [Ctrl] key.
(3) The [Copy File] dialog box is displayed.
Check the copy data then click the <Copy> button.

- 72 -
B-63344EN/02 OPERATION 1.OPERATION

Copying a file by menu or keyboard operation


(1) Click a file to be copied in the PC file list.
To select multiple files, click each file while holding down the
[Ctrl] key.
(2) Click the [Copy] command on the [File] menu or on the menu
displayed by right-clicking a selected file, or press the [Ctrl+C]
key.
(3) Select a copy destination from the folders in the PC folder tree or
the PC file list then click the copy destination.
(4) Click the [Paste] command on the [File] menu or on the menu
displayed by right-clicking the PC file list, or press the [Ctrl+V]
key.
(5) The [Copy File] dialog box is displayed.
Check the copy data then click the <Copy> button.
(6) If a file is copied by a menu or keyboard operation, the copy
source file is preserved. So, the file can be copied to another
folder in succession.
Pressing the [ESC] key clears the copy source file information.

NOTE
If a copy source and a copy destination are the
same folder, the file cannot be copied.

1.3.2.4 Moving a file


The procedure for moving a file on the PC to another PC folder is
described below.

Moving a file by drag and drop


(1) Select a file to be moved in the PC file list.
To select multiple files, click each file while holding down the
[Ctrl] key.
(2) Drag a selected file to a desired folder in the PC folder tree or the
PC file list then drop the file without pressing any key.
(3) The [Move File] dialog box is displayed.
Check the move data then click the <Move> button.

- 73 -
1.OPERATION OPERATION B-63344EN/02

Moving a file by menu or keyboard operation


(1) Click a file to be moved in the PC file list.
To select multiple files, click each file while holding down the
[Ctrl] key.
(2) Click the [Cut] command on the [File] menu or on the menu
displayed by right-clicking a selected file, or press the [Ctrl+ X]
key.
(3) Select a copy destination from the folders in the PC folder tree or
the PC file list then click the copy destination.
(4) Click the [Paste] command on the [File] menu or on the menu
displayed by right-clicking the PC file list, or press the [Ctrl+V]
key.
(5) The [Move File] dialog box is displayed.
Check the move data then click the <Move> button.

NOTE
If a move source and a move destination are the
same folder, the file cannot be moved.

- 74 -
B-63344EN/02 OPERATION 1.OPERATION

1.3.2.5 Deleting a file or folder


The procedure for deleting a file or folder on the PC is described
below.

(1) Click a file or folder (herein after simply referred to as a "file") to


be deleted in the PC file list.
To select multiple files to be deleted, click each file while
holding down the [Ctrl] key.
(2) The [Delete File] dialog box is displayed when one of the
following operations is performed:
• Press the [Delete] key.
• Click the [Delete] command on the [File] menu.
• Click the [Delete] command on the menu displayed by
right-clicking a selected file.
(3) Clicking the <Delete> button deletes a selected file. To cancel
the deletion of a selected file, click <Cancel>.

NOTE
1 When a folder is deleted, all files and folders
contained in the folder are deleted.
2 All deleted files and folders are completely erased
from the personal computer and none of them are
left in the recycle bin of Windows. Be very careful
when deleting a folder.

- 75 -
1.OPERATION OPERATION B-63344EN/02

1.3.2.6 Renaming a file or folder


The procedure for renaming a file or folder is described below.

(1) Click a file or folder to be renamed in the PC file list.


(2) Click the [Rename] command on the [File] menu or on the menu
displayed by right-clicking the selected file or folder. The
[Rename File] dialog box is displayed.
(3) Enter a new name in the [New Name] text box then click the
<Change> button. Until a name is entered in the text box, the
<Change> button is disabled.

1.3.2.7 Creating a new folder


The procedure for creating a new folder is described below.

(1) Click a folder under which a new folder is to be created in the


"My computer" (PC folder tree) then specify the folder as the PC
side current management folder.
(2) Click the [Create Folder] command on the [File] menu or on the
menu displayed by right-clicking the file list. The [Create
Folder] dialog box is displayed. However, when using the
right-click menu, right-click the mouse button at a file list
position where no files and folders are placed. If the user
right-clicks the mouse button on a file or folder, the [Create
Folder] command is not enabled.
(3) Enter the name of a folder to be created in the [New Name] text
box then click the <Create> button. Until a name is entered in
the [New Name] text box, the <Create> button is disabled.

- 76 -
B-63344EN/02 OPERATION 1.OPERATION

1.4 FILE TRANSFER TO AND FROM THE PROGRAM


MEMORY

Programs and folders in the program memory can be transferred.

1.4.1 Display of a List of Programs in the Program Memory


Select a machine from the Machine List of Connection Target.
When a machine is selected, communication starts according to the
method specified on the setting dialog.

NOTE
If communication with the data server is started,
switch the connection to the program memory by
one of the methods indicated below. When the
connection is switched, communication with the
program memory of the selected machine is
started.
• Click the [NC] button on the toolbar.
• Point to the [Change Connect] command on the
[Communication] menu to display a list of
connection destinations. Click [Program
Memory].

The PC file list displays the contents of the PC folder that is set with
the machine for display at communication start time. Refer to (2),
"Selecting PC folder to be displayed when communication is started"
in Section 1.5 "DISPLAY", of Part III, "Setting".

- 77 -
1.OPERATION OPERATION B-63344EN/02

Select McnName_002 Display the file list in the folder allocated


for McnName_002.

The Machine List of Connection Target and connection destination


file list display the following data according to a connected CNC:

- 78 -
B-63344EN/02 OPERATION 1.OPERATION

<For the Series 30i/31i/32i>


Under the connected machine name in the Machine List of Connection
Target, the folders of the program memory are displayed in tree form.
The tree also displays the [DATA] file used for transfer of data other
than programs.
The connection destination file list displays a list of the folders set in
the foreground of the first path of the CNC.

Select McnName_002

Folder tree in program memory Program list in program memory of


of McnName_002 is displayed McnName_002 is displayed

- 79 -
1.OPERATION OPERATION B-63344EN/02

<For other than the Series 30i/31i/32i>


If only one path is set with the connection destination device on the
setting dialog, the [DATA] folder used for transfer of data other than
programs is displayed in tree form under the connected machine name
in the Machine List of Connection Target. If two or more paths are
set, the [DATA] folder and path information are displayed in tree
form.
The connection destination file list displays a list of the files in the
memory of the first path of the CNC.

Select McnName_001

Path information of Program list in program memory of


McnName_001 is displayed McnName_001 is displayed

Each time the user clicks the [File List] command on the
[Communication] menu, the list of files in the program memory is
updated to the latest information.

- 80 -
B-63344EN/02 OPERATION 1.OPERATION

1.4.1.1 Changing the method of display


The method of display can be changed as indicated below by choosing
from the [Lower File List] menu on the [View] menu or choosing
from the corresponding buttons on the toolbar.

Command name on File list display


Button on the toolbar
[Lower File List] method
[Large Icon] Large icon

[List] Small icon

[Details] Display dependent on


the communication
destination device

When [Details] is selected for display, the following data is displayed


according to the CNC at the communication destination:
<Program memory of the Series 30i/31i/32i>
File name, file/folder type, comments in a program, size, last
modification date and time
<Program memory of other than the Series 30i/31i/32i>
O number, comments in a program, size, last modification date
and time

1.4.1.2 Changing the order of display


By choosing [Lower File List] then [Arrange Icons] from the [View]
menu, the user can make a selection from the following.
<Program memory of the Series 30i/31i/32i>
Sort by Name, Sort by Type, Sort by Comment, Sort by Size,
Sort by Date (last modification date and time)
<Program memory of other than the Series 30i/31i/32i.>
Sort by O Number, Sort by Comment, Sort by Size, Sort by Date
(last modification date and time)

If [Details] is selected as the file list display format, a display order


selection can also be made by clicking the following at the top of the
file list.
<Program memory of the Series 30i/31i/32i>
[File Name], [Type], [Comment], [Size], [Last Modification
Date]

- 81 -
1.OPERATION OPERATION B-63344EN/02

<Program memory of other than the Series 30i/31i/32i>


[O Number], [Comment], [Size], [Last Modification Date]

1.4.1.3 Changing the path of the CNC under communication


If two or more paths are set with a connection destination device other
than the Series 30i /31i /32i on the setting dialog, the communication
target path can be changed.

(1) Paths are displayed under a machine name in the Machine List of
Connection Target. Click a desired path. Alternatively, point
to the [Change Path] command on the [Communication] menu.
A list of paths is displayed. Click a desired path.

(2) Communication is switched to the selected path, and the display


of the connection destination file list switches to the information
of the path selected for communication.
The connection destination current management status bar
displays the currently selected path. The Machine List of
Connection Target displays the currently selected path in reverse
video.

selected path

- 82 -
B-63344EN/02 OPERATION 1.OPERATION

1.4.2 File Transfer to and from the Program Memory

1.4.2.1 Uploading from the program memory to the PC


(1) Click a file to be uploaded in the connection destination file list.
To select multiple files to be uploaded, click each file while
holding down the [Ctrl] key. With the Series 30i/31i/32i, a
folder can also be selected.
(2) Perform one of the following operations:
A) Drag and drop a file selected in the connection destination
file list onto the PC file list. When the selected file is
dropped on a file or blank area of the PC file list, the file is
uploaded to the folder displayed in the PC file list. When
the file is dropped onto the folder in the PC file list, the file
can be uploaded to the folder.
B) Drag and drop a file selected in the connection destination
file list onto the PC folder tree.
C) Click the [Upload] command on the [Communication] menu
or on the menu displayed by right-clicking a selected file.
If a file is selected in the PC file list, the selected file is
uploaded to the folder displayed in the PC file list.
If a folder is selected in the PC file list, the selected file is
uploaded to the folder.
A

- 83 -
1.OPERATION OPERATION B-63344EN/02

NOTE
When the [Upload] menu is used to upload a file,
the file is uploaded to a folder selected, if any, in
the PC file list. Before operating the menu, check
for a file or folder selected in the PC file list.

(3) The [Upload Program] dialog box is displayed according to the


contents to be uploaded.
When only files are uploaded, the dialog box shown below is
displayed.
<When only files are uploaded>

If a file with the same name exists on the PC, a message for
checking whether the existing file may be overwritten is output
as shown below.

When only folders are uploaded or files and folders are uploaded,
the dialog box shown below is displayed. Select an upload
option.

- 84 -
B-63344EN/02 OPERATION 1.OPERATION

<When folders are uploaded>

The upload options are described below.


Can not overwrite Does not write over a file with the same
name if existing at the upload destination.
Cancel the process Stops processing when a file or folder
when it failed. upload operation fails. No additional
files and folders are uploaded.
Upload under the Upload all subfolders contained in a
subfolders too. selected folder and all files under each of
those subfolders.

(4) Click the <Upload> button.


If folders are included, the following result dialog box is
displayed each time a selected folder is uploaded:

• Selected folder: Indicates the path of a folder to be


uploaded. In the "File Name" column of
the screen, "/" is indicated.

- 85 -
1.OPERATION OPERATION B-63344EN/02

• Process: Indicates upload processing.


Process Meaning
New When a file is uploaded
- There is no existing file with the same name on
the PC, so that the file is uploaded.
When a folder is uploaded
- There is no existing folder with the same name on
the PC, so that a folder is newly created.
Overwrite When a file is uploaded
- There is an existing file with the same name on
the PC, so that the file is uploaded and written
over the existing file.
Skip When a file is uploaded
- There is an existing file with the same name on
the PC, so that the file is not uploaded.
When a folder is uploaded
- There is an existing folder with the same name on
the PC, so that no folder is created. The files
and subfolders under the target folder are
uploaded.
• Result: Indicates whether uploading was
successful or not.
• Error Message: An error message is displayed when
uploading has failed.

(5) A selected file is uploaded to the PC and the PC file list is


updated to the latest information accordingly.

NOTE
1 With a CNC supporting file name management
such as the Series 30i/31i/32i, a distinction can be
made between the uppercase and lowercase
letters. With the Windows OS, however, such a
distinction is impossible.
With a CNC, therefore, a file named AAA and a file
named aaa can be created. However, if AAA and
aaa are uploaded in this order to the PC, AAA is
replaced with aaa when aaa is uploaded.
2 Upload will be canceled if a Cancel button is
clicked during upload.
The folder and file which upload completed before
cancellation remain in PC. Delete these, if these
are unnecessary.
The file uploaded at the time of cancellation is
deleted.

- 86 -
B-63344EN/02 OPERATION 1.OPERATION

1.4.2.2 Downloading from the PC to the program memory


(1) Click a file to be downloaded in the PC file list. To select
multiple files to be downloaded, click each file while holding
down the [Ctrl] key. When the connection destination device is
the Series 30i/31i/32i, a folder can also be selected.
(2) Perform one of the following operations:
A) Drag and drop a file selected in the PC file list onto the
connection destination file list. When the selected file is
dropped on a file or blank area of the connection destination
file list, the file is downloaded to the folder displayed in the
connection destination file list. When the file is dropped
onto the folder in the connection destination file list, the file
can be downloaded to the folder. (Operation for dropping
a file onto a folder is possible only when the connection
destination device is the Series 30i/31i/32i.)
B) Drag and drop a file selected in the PC file list onto a folder
under the connected machine name in the Machine List of
Connection Target. (This operation is possible only when
the connection destination device is the Series 30i/31i/32i.)
C) Click the [Download] command on the [Communication]
menu or on the menu displayed by right-clicking a selected
file.
If a file is selected in the connection destination file list, the
selected file is downloaded to the folder displayed in the
connection destination file list.
If a folder is selected in the connection destination file list,
the selected file is downloaded to the folder. (Operation
for downloading a file onto a folder is possible only when
the connection destination device is the Series 30i/31i/32i.)

B A

- 87 -
1.OPERATION OPERATION B-63344EN/02

NOTE
1 When the connection destination device is the
Series 30i/31i/32i and the [Download] command on
the menu is used to download a file, the file is
downloaded to a folder selected, if any, in the
connection destination file list.
Before operating the menu, check for a file or folder
selected in the connection destination file list.
2 When the connection destination device is a
multipath device other than the Series 30i/31i/32i,
folders indicating path names are displayed in the
Machine List of Connection Target. However,
downloading to a path not created is impossible.

(3) The [Download Program] dialog box is displayed according to


the contents to be downloaded.
When only files are downloaded, the dialog box shown below is
displayed.

<When only files are downloaded>

When only folders are downloaded or files and folders are


downloaded, the dialog box shown below is displayed. Select a
download option.

- 88 -
B-63344EN/02 OPERATION 1.OPERATION

<When folders are downloaded>

The download options are described below.


Cancel the process Stops processing when a file or folder
when it failed. download operation fails. No additional
files and folders are downloaded.
Download under the Downloads all subfolders contained in a
subfolders too. selected folder and all files under each of
those subfolders.

(4) Click the <Download> button.


If the CNC parameter is set to enable overwriting (when bit 3 of
parameter No. 3201 is set to 1), the user is requested to confirm
whether to perform overwriting as indicated below.

<Yes>: Executes all download operations.


<No>: Cancels all download operations.

- 89 -
1.OPERATION OPERATION B-63344EN/02

If folders are included, the following result dialog box is


displayed each time a selected folder is downloaded:

• Selected folder: Indicates the path of a download


destination folder.
• Process: Indicates download processing.
Process Meaning
New When a file is downloaded
- There is no existing file with the same name in the
program memory, so that the file is downloaded.
- There is an existing file with the same name in the
program memory, so that the file is downloaded and
written over the existing file.
When a folder is downloaded
- There is no existing folder with the same name in
the program memory, so that a folder is newly
created.
Skip When a folder is downloaded
- There is an existing folder with the same name in
the program memory, so that no folder is created.
The files and subfolders under the target folder are
downloaded.
• Result: Indicates whether downloading was
successful or not.
• Error Message: An error message is displayed when
downloading has failed.

- 90 -
B-63344EN/02 OPERATION 1.OPERATION

(5) A selected file is downloaded to the CNC and the connection


destination file list is updated to the latest information
accordingly.

NOTE
1 A program name assigned by the CNC at
download time is not the file name on the PC but
the program name written in the file.
2 A program may be overwritten, depending on the
setting of the CNC parameter for enabling
overwriting. At the time of downloading, carefully
check whether a program name with the same
name exists.
3 Download will be canceled if a Cancel button is
clicked during download.
The folder and file which download completed
before cancellation, and the file downloaded at the
time of cancellation remain in CNC program
memory. Delete these, if these are unnecessary.

- 91 -
1.OPERATION OPERATION B-63344EN/02

1.4.3 Operating Files and Folders in the Program Memory

1.4.3.1 Deleting a file or folder

NOTE
A folder in the program memory can be deleted
only when communication is performed with the
Series 30i/31i/32i.

(1) Click a file or folder (herein after simply referred to as a "file") to


be deleted in the file list.
To select multiple files to be deleted, click each file while
holding down the [Ctrl] key.
(2) The deletion confirmation dialog box is displayed when one of
the following operations is performed:
• Press the [Delete] key.
• Click the [Delete] command on the [Communication] menu.
• Click the [Delete] command on the menu displayed by
right-clicking a selected file.

(3) Clicking the <Delete> button deletes a selected file. To cancel


the deletion of a selected file, click <Cancel>.

NOTE
1 When a folder is deleted, all files and folders
contained in the folder are deleted.
2 All deleted files and folders are completely erased
from the connection destination. Use special
care when deleting a file or folder.

- 92 -
B-63344EN/02 OPERATION 1.OPERATION

1.4.3.2 Renaming a file or folder

NOTE
A file or folder in the program memory can be
renamed only when communication is performed
with the Series 30i/31i/32i.

(1) Click a file or folder to be renamed in the file list.


(2) Click the [Rename] command on the [Communication] menu or
on the menu displayed by right-clicking the selected file or folder.
The [Rename File] dialog box is displayed.

(3) Enter a new name in the [New Name] text box then click the
<Change> button. Until a name is entered in the text box, the
<Change> button is disabled.

- 93 -
1.OPERATION OPERATION B-63344EN/02

1.4.3.3 Creating a new folder

NOTE
A new folder can be created in the program
memory only when communication is performed
with the Series 30i/31i/32i.

(1) Click a folder under which a new folder is to be created in the


Machine List of Connection Target then specify the folder as the
connection destination current management folder.
(2) Click the [Create Folder] command on the [Communication]
menu or on the menu displayed by right-clicking the connection
destination file list. The [Create Folder] dialog box is displayed.
However, when using the right-click menu, right-click the mouse
button at a file list position where no files and folders are placed.
If the user right-clicks the mouse button on a file or folder, the
[Create Folder] command is not enabled.

(3) Enter the name of a folder to be created in the [New Name] text
box then click the <Create> button. Until a name is entered in
the [New Name] text box, the <Create> button is disabled.

- 94 -
B-63344EN/02 OPERATION 1.OPERATION

1.5 TRANSFER OF DATA OTHER THAN PROGRAMS

The following data other than programs can be transferred between


the PC and CNC:
• Tool offset
• Custom macro variable (common variable)
• Workpiece origin offset
The format used for uploading these types of data is the same as the
format used for output from the CNC to an external device.

NOTE
1 The name of a file that is displayed with the Program
Transfer Tool and contains data other than programs
is the same as the name of a file used when bit 0 of
parameter No. 138 is set to 1 on the CNC and data is
output to a memory card without specifying a file
name. When reading an uploaded file to the CNC by
using a memory card, be sure to set bit 0 of
parameter No. 138 to 1 on the CNC.
2 If the name of a file is changed at the time of
uploading, a path number and data type need to be
selected when the file is downloaded from the PC to
the CNC. If an incorrect path number or data type is
selected, data in the CNC can be destructed. Care
must be taken.
3 If an uploaded file is transferred to a memory card
then the data is read to the CNC from the memory
card, the file name needs to satisfy the following 8.3
format:
XXXXXXXX.YYY

8 characters or less 3 characters or less for extension

- 95 -
1.OPERATION OPERATION B-63344EN/02

1.5.1 Display of a Data List


When communication is performed with the program memory, the
[DATA] folder is displayed in the tree view of the program memory.
Clicking this folder displays a list of transferable data other than
programs in the file list of the program memory.

NOTE
1 This tool displays the [DATA] folder on the screen,
but the [DATA] folder does not exist in the program
memory of the CNC. The [DATA] folder is a
virtual folder displayed on the screen by this tool.
2 Data that requires the CNC option, such as custom
macro variables, is not displayed when the CNC
option is not selected.

The table below indicates the file names for transferable data.
Custom macro Workpiece
Tool offset
variable origin offset
Series 30i/31i/32i-A
TOOLOFST.TXT MACRO.TXT EXT_WKZ.TXT
Series 0i-D
Series 16i/18i/21i-A/B
Series 0i-B/C TOOLOFST.DAT MACROVAR.DAT WORK-G54.DAT
Series 20i-B
Power Mate i-D/H TOOLOFST.DAT MACROVAR.DAT None
* The file names above are for data of the first path. For data of a
second or subsequent path, the extension "P-path-number" is
used. However, for the tenth path, the extension is "P10".
Example:
Tool offset data of the second path: TOOLOFST.P-2
Tool offset data of the tenth path: TOOLOFST.P10

- 96 -
B-63344EN/02 OPERATION 1.OPERATION

Example of display: For the Series 30i/31i/32i

[DATA]Folder File list in[DATA]Folder

Example of display: For other than the Series 30i/31i/32i

[DATA]Folder File list in[DATA]Folder

- 97 -
1.OPERATION OPERATION B-63344EN/02

1.5.1.1 Changing the method of display


The method of display can be changed as indicated below by choosing
from the [Lower File List] menu on the [View] menu or choosing
from the corresponding buttons on the toolbar.

Command name on Button on the File list display


[Lower File List] toolbar method
[Large Icon] Large icon

[List] Small icon

[Details] Detailed display (file


names only)

When [Details] is selected for display, file names, types, and path No.
are displayed. No comment, size, and last modification date and time
are displayed.

- 98 -
B-63344EN/02 OPERATION 1.OPERATION

1.5.2 Uploading from the CNC to the PC


(1) Click the [DATA] folder in the Machine List of Connection
Target to display a list of data in the file list.
(2) Click a file to be uploaded in the connection destination file list.
To select multiple files to be uploaded, click each file while
holding down the [Ctrl] key.
(3) Perform one of the following operations:
A) Drag and drop a file selected in the connection destination
file list onto the PC file list. When the selected file is
dropped on a file or blank area of the PC file list, the file is
uploaded to the folder displayed in the PC file list. When
the file is dropped onto the folder in the PC file list, the file
can be uploaded to the folder.
B) Drag and drop a file selected in the connection destination
file list onto the PC folder tree.
C) Click the [Upload] command on the [Communication] menu
or on the menu displayed by right-clicking a selected file.
If a file is selected in the PC file list, the selected file is
uploaded to the folder displayed in the PC file list.
If a folder is selected in the PC file list, the selected file is
uploaded to the folder. (This operation is omitted in the
figure.)
B C A

NOTE
When the [Upload] menu is used to upload a file,
the file is uploaded to a folder selected, if any, in
the PC file list. Before operating the menu, check
for a file or folder selected in the PC file list.

- 99 -
1.OPERATION OPERATION B-63344EN/02

(4) A dialog box for CNC data upload confirmation is displayed.

<Yes>: Executes uploading.


<Upload All>: Executes all subsequent upload operations
without displaying the confirmation dialog box.
The name of an uploaded file is the same as the
selected file name. To the data set on this
screen, the specified file name is assigned.
<Skip>: Stops the uploading of the data being confirmed
on this screen.
<Cancel>: Cancels all subsequent upload operations.

(5) Click the <Yes> or <Upload All> button.


If a file with the same name exists on the PC, a message for
checking whether the existing file may be overwritten is output.

(6) Upon completion of uploading to the PC, the PC file list is


updated to the latest information accordingly.

- 100 -
B-63344EN/02 OPERATION 1.OPERATION

1.5.3 Downloading from the PC to the CNC

NOTE
1 If the name of a file is changed at the time of
uploading, a path number and data type need to be
selected when the file is downloaded from the PC
to the CNC. If an incorrect path number or data
type is selected, data in the CNC can be
destructed. Care must be taken.
2 If data such as tool offsets, custom macros, and
workpiece origin offsets other than programs is
downloaded from the PC to the CNC, the
corresponding data of the CNC is updated.
Before starting download operation, check whether
the data of the CNC may be updated.

(1) Click a file to be downloaded in the PC file list. To select


multiple files to be downloaded, click each file while holding
down the [Ctrl] key.
C

A B
(2) Perform one of the following operations:
A) Drag and drop a selected file onto the [DATA] folder in the
Machine List of Connection Target.
B) Click the [DATA] folder in the Machine List of Connection
Target then drag and drop a selected file onto the file list.

- 101 -
1.OPERATION OPERATION B-63344EN/02

C) Click the [DATA] folder in the Machine List of Connection


Target. Then click the [Download] command on the
[Communication] menu or on the menu displayed by
right-clicking a selected file.

(3) A dialog box for CNC data update confirmation is displayed.

<Yes>: Executes downloading to update the data of the CNC.


<Skip>: Stops the downloading of the data being confirmed on
this screen.
<Cancel>: Cancels all subsequent download operations.

(4) Click the <Yes> button. The selected file is downloaded to the
CNC to update the data of the CNC.

- 102 -
B-63344EN/02 OPERATION 1.OPERATION

1.6 FILE TRANSFER TO AND FROM THE DATA SERVER

By performing communication with the data server, programs and


folders on an external storage media (such as a compact flash card and
hard disk) of the data server can be transferred.

1.6.1 Display of a List of Files on the Data Server


Select a machine from the Machine List of Connection Target.
When a machine is selected, communication is started according to the
method specified on the setting dialog.

NOTE
If communication with the program memory is
started, switch the connection to the data server by
one of the methods indicated below. When the
connection is switched, communication with the
data server of the selected machine is started.
- Click the [DS] button on the toolbar.
- Point to the [Change Connect] command on the
[Communication] menu to display a list of
connection destinations. Click [Data Server].

Under the connected machine name in the Machine List of Connection


Target, the folders of the connection destination machine are
displayed in tree form.
If a login folder is set on the setting dialog, the connection destination
file list displays a list of the files of the folder. If no login folder is
set, a list of the files of the login folder set at the connection
destination is displayed.

- 103 -
1.OPERATION OPERATION B-63344EN/02

Select McnName_002

Folder information in DATA Files in DATA SERVER


SERVER of McnName_002 of McnName_002 are displayed
are displayed
Each time the user clicks [File List] command on the
[Communication] menu, the list of files at the connection destination
is updated to the latest information.

- 104 -
B-63344EN/02 OPERATION 1.OPERATION

1.6.1.1 Changing the method of display


The method of display can be changed as indicated below by choosing
from the [Lower File List] menu on the [View] menu or choosing
from the corresponding buttons on the toolbar.

Command name on Button on the


File list display method
[Lower File List] toolbar
[Large Icon] Large icon

[List] Small icon

[Details] Detailed display of the following:


File name, file/folder type, size
(bytes), last modification data
and time

1.6.1.2 Changing the order of display


By choosing [Lower File List] then [Arrange Icons] from the [View]
menu, the user can make a selection from Sort by Name, Sort by Type,
Sort by Size, and Sort by Date (last modification date and time).

If [Details] is selected as the file list display format, a display order


selection can also be made by clicking [File Name], [Type], [Size], or
[Last Modification Date] at the top of the file list.

- 105 -
1.OPERATION OPERATION B-63344EN/02

1.6.2 File Transfer to and from the Data Server

NOTE
For file transfer to and from the data server, a file
transfer format can be selected. For details, see
Subsection 1.7.3, "Communication Tab".

1.6.2.1 Uploading from the data server to the PC


(1) Click a file to be uploaded in the connection destination file list.
To select multiple files to be uploaded, click each file while
holding down the [Ctrl] key.
(2) Perform one of the following operations:
A) Drag and drop a file selected in the connection destination
file list onto the PC file list. When the selected file is
dropped on a file or blank area of the PC file list, the file is
uploaded to the folder displayed in the PC file list. When
the file is dropped onto the folder in the PC file list, the file
can be uploaded to the folder.
B) Drag and drop a file selected in the connection destination
file list onto the PC folder tree.
C) Click the [Upload] command on the [Communication] menu
or on the menu displayed by right-clicking a selected file.
If a file is selected in the PC file list, the selected file is
uploaded to the folder displayed in the PC file list.
If a folder is selected in the PC file list, the selected file is
uploaded to the folder.
A

- 106 -
B-63344EN/02 OPERATION 1.OPERATION

NOTE
When the [Upload] menu is used to upload a file,
the file is uploaded to a folder selected, if any, in
the PC file list. Before operating the menu, check
for a file or folder selected in the PC file list.

(3) The [Upload Program] dialog box is displayed according to the


contents to be uploaded.
When only files are uploaded, the dialog box shown below is
displayed.
<When only files are uploaded>

If a file with the same name exists on the PC, a message for
checking whether the existing file may be overwritten is output
as shown below.

When only folders are uploaded or files and folders are uploaded,
the dialog box shown below is displayed. Select an upload
option.

- 107 -
1.OPERATION OPERATION B-63344EN/02

<When folders are uploaded>

The upload options are described below.


Can not overwrite Does not write over a file with the same
name if existing at the upload destination.
Cancel the process Stops processing when a file or folder
when it failed. upload operation fails. No additional
files and folders are uploaded.
Upload under the Upload all subfolders contained in a
subfolders too. selected folder and all files under each of
those subfolders.

(4) Click the <Upload> button.


If folders are included, the following result dialog box is
displayed each time a selected folder is uploaded:

- 108 -
B-63344EN/02 OPERATION 1.OPERATION

• Selected folder: Indicates the path of a folder to be


uploaded. In the "File Name" column of
the screen, "/" is indicated.
• Process: Indicates upload processing.
Process Meaning
New When a file is uploaded
- There is no existing file with the same name on
the PC, so that the file is uploaded.
When a folder is uploaded
- There is no existing folder with the same name on
the PC, so that a folder is newly created.
Overwrite When a file is uploaded
- There is an existing file with the same name on
the PC, so that the file is uploaded and written
over the existing file.
Skip When a file is uploaded
- There is an existing file with the same name on
the PC, so that the file is not uploaded.
When a folder is uploaded
- There is an existing folder with the same name on
the PC, so that no folder is created. The files
and subfolders under the target folder are
uploaded.
• Result: Indicates whether uploading was
successful or not.
• Error Message: An error message is displayed when
uploading has failed.

(5) A selected file is uploaded to the PC and the PC file list is


updated to the latest information accordingly.

NOTE
1 With a CNC supporting file name management
such as the Series 30i/31i/32i and Series 0i-D, a
distinction can be made between the uppercase
and lowercase letters. With the Windows OS,
however, such a distinction is impossible.
With a CNC, therefore, a file named AAA and a file
named aaa can be created. However, if AAA and
aaa are uploaded in this order to the PC, AAA is
replaced with aaa when aaa is uploaded.
2 Upload will be canceled if a Cancel button is
clicked during upload.
The folder and file which upload completed before
cancellation, and the file uploaded at the time of
cancellation remain in PC. Delete these, if these
are unnecessary.

- 109 -
1.OPERATION OPERATION B-63344EN/02

1.6.2.2 Downloading from the PC to the data server

NOTE
If a file that has the same name as a file to be
downloaded exists on the data server, the file
cannot be downloaded and written over the existing
file.

Before downloading the file, delete the existing file


with the same name on the data server.
* If the DataServer Explorer connection option is
selected with the Series 30i/31i/32i, a file can be
downloaded and written over an existing file with
the same name by setting bit 2 of parameter No.
906 to 1 to enable overwriting. When
downloading a file, carefully check whether a file
with the same name exists.

(1) Click a file to be downloaded in the PC file list. To select


multiple files to be downloaded, click each file while holding
down the [Ctrl] key.
(2) Perform one of the following operations:
A) Drag and drop a file selected in the PC file list onto the
connection destination file list. When the selected file is
dropped on a file or blank area of the connection destination
file list, the file is downloaded to the folder displayed in the
connection destination file list. When the file is dropped
onto the folder in the connection destination file list, the file
can be downloaded to the folder.
B) Drag and drop a file selected in the PC file list onto a folder
under the connected machine name in the Machine List of
Connection Target.
C) Click the [Download] command on the [Communication]
menu or on the menu displayed by right-clicking a selected
file.
If a file is selected in the connection destination file list, the
selected file is downloaded to the folder displayed in the
connection destination file list.
If a folder is selected in the connection destination file list,
the selected file is downloaded to the folder.

- 110 -
B-63344EN/02 OPERATION 1.OPERATION

B A

NOTE
When the [Download] command on the menu is
used to download a file, the file is downloaded to a
folder selected, if any, in the connection destination
file list.
Before operating the menu, check for a file or folder
selected in the connection destination file list.

(3) The [Download Program] dialog box is displayed according to


the contents to be downloaded.

When only files are downloaded, the dialog box shown below is
displayed.
<When only files are downloaded>

When only folders are downloaded or files and folders are


downloaded, the dialog box shown below is displayed. Select a
download option.
<When folders are downloaded>

- 111 -
1.OPERATION OPERATION B-63344EN/02

The download options are described below.


Cancel the process Stops processing when a file or folder
when it failed. download operation fails. No additional
files and folders are downloaded.
Download under the Downloads all subfolders contained in a
subfolders too. selected folder and all files under each of
those subfolders.

(4) Click the <Download> button.


If the DataServer Explorer connection option is selected with the
Series 30i/31i/32i and bit 2 of CNC parameter No. 906 is set to 1
to enable overwriting, the user is requested to confirm whether to
perform overwriting as indicated below.

<Yes>: Executes all download operations.


<No>: Cancels all download operations.

- 112 -
B-63344EN/02 OPERATION 1.OPERATION

If folders are included, the following result dialog box is


displayed each time a selected folder is downloaded:

• Selected folder: Indicates the path of a download


destination folder.
• Process: Indicates download processing.
Process Meaning
New When a file is downloaded
- There is no existing file with the same name on the
data server, so that the file is downloaded.
- There is an existing file with the same name on the
data server, so that the file is downloaded and
written over the existing file.
When a folder is downloaded
- There is no existing folder with the same name on
the data server, so that a folder is newly created.
Skip When a folder is downloaded
- There is an existing folder with the same name on
the data server, so that no folder is created. The
files and subfolders under the target folder are
downloaded.
• Result: Indicates whether downloading was
successful or not.
• Error Message: An error message is displayed when
downloading has failed.

- 113 -
1.OPERATION OPERATION B-63344EN/02

(5) A selected file is downloaded to the connection destination and


the connection destination file list is updated to the latest
information accordingly.

NOTE
1 The file name assigned by the data server to a downloaded file is the
same as for a file to be downloaded. With other than the Series
30i/31i/32i and Series 0i-D, if the format of the file name is not the 8.3
format, however, the format is automatically converted to the 8.3
format. Note that when files handled as separate files on the PC are
downloaded to the data server, those files may be assumed to have the
same name.
2 With the Series 30i/31i/32i and Series 0i-D, the program name in a
downloaded file depends on the data server transfer format as
described below.
<For binary transfer>
The program name in the file remains unchanged.
<For text transfer>
The program name in the file is changed to the same as for the
name of a file to be downloaded.
With other than the Series 30i/31i/32i and Series 0i-D, the program
name in a downloaded file remains unchanged.

- 114 -
B-63344EN/02 OPERATION 1.OPERATION

NOTE
3 If a file not in the program format is downloaded to the data server of
the Series 30i/31i/32i and Series 0i-D, the contents of the file may be
automatically modified.
Example:
When a file with no program name is downloaded by text transfer
File name on the PC: EXT_WKZ.TXT
%
G90
G10L2P0X2.2Y0.0Z0.0C0.0
---
M02
%

Downloaded

%
<EXT_WKZ.TXT> A program name is added.
G90
G10L2P0X2.2Y0.0Z0.0C0.0
---
M02
%

4 Download will be canceled if a Cancel button is clicked during


download.
The folder and file which download completed before cancellation, and
the file downloaded at the time of cancellation remain in DATA
SERVER. Delete these, if these are unnecessary.

- 115 -
1.OPERATION OPERATION B-63344EN/02

1.6.3 Operating Files and Folders on the Data Server

1.6.3.1 Deleting a file or folder


(1) Click a file or folder (herein after simply referred to as a "file") to
be deleted in the file list.
To select multiple files to be deleted, click each file while
holding down the [Ctrl] key.
(2) The deletion confirmation dialog box is displayed when one of
the following operations is performed:
• Press the [Delete] key.
• Click the [Delete] command on the [Communication] menu.
• Click the [Delete] command on the menu displayed by
right-clicking a selected file.

(3) Clicking the <Delete> button deletes a selected file.


To cancel the deletion of a selected file, click <Cancel>.

NOTE
1 When a folder is deleted, all files and folders
contained in the folder are deleted.
2 All deleted files and folders are completely erased
from the connection destination. Be very careful
when deleting a file or folder.

- 116 -
B-63344EN/02 OPERATION 1.OPERATION

1.6.3.2 Renaming a file or folder


(1) Click a file or folder to be renamed in the file list.
(2) Click the [Rename] command on the [Communication] menu or
on the menu displayed by right-clicking the selected file. The
[Rename File] dialog box is displayed.

(3) Enter a new name in the [New Name] text box then click the
<Change> button. Until a name is entered in the text box, the
<Change> button is disabled.

1.6.3.3 Creating a new folder


(1) Click a folder under which a new folder is to be created in the
Machine List of Connection Target then specify the folder as the
connection destination current management folder.
(2) Click the [Create Folder] command on the [Communication]
menu or on the menu displayed by right-clicking the connection
destination file list. The [Create Folder] dialog box is displayed.
However, when using the right-click menu, right-click the mouse
button at a file list position where no files and folders are placed.
If the user right-clicks the mouse button on a file or folder, the
[Create Folder] command is not enabled.

(3) Enter the name of a folder to be created in the [New Name] text
box then click the <Create> button. Until a name is entered in
the [New Name] text box, the <Create> button is disabled.

- 117 -
1.OPERATION OPERATION B-63344EN/02

1.7 SETTING OF OPTIONS

Clicking the [Options] command on the [Tools] menu displays the


[Options] dialog box.
New settings can be made effective by clicking the <OK> button after
making the settings.
To cancel settings and return to the original values, click the <Cancel>
button.

1.7.1 Listing Tab

In the [File List] frame, make settings related to file list display.
• If the [Refresh File List before sort] check box is checked, the
latest file list information is acquired before changing the order
of file list display.
If this check box is not checked, the order of file list display is
changed according to the contents currently displayed in the file
list.
If the file list consists of multiple pages of data, the latest file list
information is acquired before changing the order of file list
display, regardless of the setting of this check box.
• If the [Not display message at page move] check box is checked,
the file list page switch confirmation dialog box is not displayed.
• If the value of the [Number of displayed files in a page] box is
changed, the number of files displayable per page of the file list
can be changed.
• In the [Double click on PC file list] frame, the user can select an
operation to be performed when the user double-clicks each file.

- 118 -
B-63344EN/02 OPERATION 1.OPERATION

1.7.2 View, Edit Tab

(1) In the [File View] frame, make a setting related to file viewing.
• When the [Not Specify Viewer] option is selected, [File
Viewer] built into the Program Transfer Tool is used to
view a file.
• When the [Specify Viewer] option is selected, a file can be
viewed using a specified viewer. In the [Viewer
command] box, enter a viewer command to be started.
(2) In the [File Edit] frame, make a setting related to file editing.
• When the [Not Specify Editor] option is selected, Notepad
of the Windows OS is used to edit a file.
• When the [Specify Editor] option is selected, a file can be
edited using a specified editor. In the [Editor command]
box, enter an editor command to be started.

- 119 -
1.OPERATION OPERATION B-63344EN/02

1.7.3 Communication Tab

In the [Communication] frame, make settings related to


communication with the CNC.
• By checking the [Display Program Folders tree view at high
speed] check box, a tree view of program memory folders
displayed when the program memory is connected can be
displayed at high speed. However, the mark (+) is prefixed to
each folder, regardless of whether child folders are present (with
the Series 30i/31i/32i only).
• By checking the [Display Data Server tree view at high speed]
check box, a tree view of the data server displayed when the data
server is connected can be displayed at high speed. However,
the mark (+) is prefixed to each folder, regardless of whether
child folders are present.
• In the [Data Server file transfer type] frame, a type of file transfer
to and from the data server can be selected.

NOTE
With the data server of Series 6569/Edition 14 or
later for the Series 30i/31i/32i and the data server
of Series 658W for Series 0i-D, the data storage
format can be set using parameter No. 929,
regardless of the transfer mode specification on the
PC.
0: Data is stored according to the transfer mode
specified on the PC (as conventionally done).
1: Data is stored in the text format.
2: Data is stored in the binary format.
When using a data server with this parameter
made valid, set the parameter above to 0 to enable
the transfer mode of this tool.

- 120 -
APPENDIX
B-63344EN/02 APPENDIX A.SETTING OF THE CNC

A SETTING OF THE CNC


The Ethernet setting of the CNC is described below.

CAUTION
When using the Ethernet board or Fast Ethernet
board function for the first time, carefully set an IP
address and so forth and sufficiently conduct a
communication test, consulting with the network
administrator of your company.
If an IP address, for example, is set incorrectly,
the operation of the entire network can suffer from
a communication error. Care must be taken.
Particularly, if a duplicate IP address is set, a
communication error can occur intermittently,
resulting in a CNC system error. Care must be
taken.

NOTE
1 To use the FOCAS2/Ethernet function, the option
function for each CNC used is required.
For details, see "Ethernet board or data server
board and CNC options" in Section 3.1, "CNC", of
Chapter 3, OPERATING ENVIRONMENT", of
Part I, "GENERAL".
2 This chapter describes an example of setting for
creating a new small network (with no router)
where a PC and CNC are connected with each
other.
When building a large network or making an
addition to an existing network, set the IP
addresses, subnet masks, and router IP
addresses of a PC and CNCs, consulting with the
network administrator of your company.

- 123 -
A.SETTING OF THE CNC APPENDIX B-63344EN/02

Setting for using the function for communication with the program memory
An example of minimum required setting for operating the function
for communication with the program memory on a small network is
provided below.

CNC PC

Ethernet hub

Example of CNC setting


Location of setting Setting item CNC setting value Remarks
Ensure that this IP address does
not duplicate the IP addresses of
IP address 192.168.0.1
other CNCs and personal
computers.
Ethernet parameter screen
Subnet mask 255.255.255.0
of the CNC

Router IP address None

TCP port number 8193

Example of PC setting
Location of setting Setting item PC setting value Remarks
Ensure that this IP address does
not duplicate the IP addresses of
IP address 192.168.0.101
other CNCs and personal
"Microsoft TCP/IP computers.
properties" of Windows OS
Subnet mask 255.255.255.0

Default gateway None

Set the IP address set for the


Program Transfer Tool IP address 192.168.0.1
CNC.
setting screen
Set the port number set for the
Program memory tab TCP port number 8193
CNC.

- 124 -
B-63344EN/02 APPENDIX A.SETTING OF THE CNC

Setting for using the function for communication with the data server
An example of minimum required setting for operating the function
for communication with the data server on a small network is provided
below. An FTP Server on CNC is required.
CNC PC

Ethernet hub

Example of CNC setting


Location of setting Setting item CNC setting value Remarks
Ensure that this IP address does
not duplicate the IP addresses of
IP address 192.168.0.1
other CNCs and personal
computers.

Subnet mask 255.255.255.0

Ethernet parameter screen Router IP address None


of the CNC
Port number 21

User name dtsvr


FTP
server Password dtsvr

Login DIR None

Example of PC setting
Location of setting Setting item PC setting item Remarks
Ensure that this IP address does
not duplicate the IP addresses of
IP address 192.168.0.101
other CNCs and personal
"Microsoft TCP/IP computers.
properties" of Windows OS
Subnet mask 255.255.255.0

Default gateway None

Set the IP address set for the


IP address 192.168.0.1
CNC.
Set the user name set for the
User name dtsvr
Program Transfer Tool CNC.
setting screen Password dtsvr Set the password set for the CNC.
Data server tab Set the port number set for the
FTP port number 21
CNC.
Login folder None

- 125 -
B.Windows Firewall Settings APPENDIX B-63344EN/02

B Windows Firewall Settings


It is necessary to set the Windows Firewall to communicate with
DATA SERVER with some of Windows OS.
However, if you don't communicate with DATA SERVER, the
following setting is not necessary.

- 126 -
B-63344EN/02 APPENDIX B.Windows Firewall Settings

B.1 In Case of Using Windows 2000 Service Pack 4

It is not necessary to set the Windows Firewall to communicate with


DATA SERVER.

B.2 In Case of Using Windows XP Service Pack 2

Set the Windows Firewall as the following procedure.

(1) Open the "Control panel", activate the "Security Center", and
click the "Windows Firewall".

- 127 -
B.Windows Firewall Settings APPENDIX B-63344EN/02

(2) In "General" tab, confirm that "On (recommendation)" is


checked and "Don't allow exceptions" is not checked.

- 128 -
B-63344EN/02 APPENDIX B.Windows Firewall Settings

(3) Click "Exceptions" tab, and confirm "Display a notification when


Windows Firewall blocks a program" is checked.
Next, click [Add Program...] button.

- 129 -
B.Windows Firewall Settings APPENDIX B-63344EN/02

(4) There is the "Program Transfer Tool" on the "Add a Program"


screen. After selecting it, click the <OK> button.

When there is not "Program Transfer Tool", click the "Browse"


button. Display the "Bin" folder under the folder where you
install Program Transfer Tool. Then select the "PttMain.exe"
and click the <Open> button. Since the "Add a Program" screen
is displayed again, select the "PttMain.exe" and click the <OK>
button.

- 130 -
B-63344EN/02 APPENDIX B.Windows Firewall Settings

(5) Confirm that the "Program Transfer Tool (or PttMain.exe)" was
added to the "Programs and Services" list as shown in the
following figure.

- 131 -
B.Windows Firewall Settings APPENDIX B-63344EN/02

(6) Add "FethDgn.exe" to the "Exceptions" by above procedures.


In the procedure (4), select "Ethernet communication test"
instead of "Program Transfer Tool" and "FethDgn.exe" instead of
"PttMain.exe".
Then confirm that the "Ethernet communication test (or
FethDgn.exe)" and the "Program Transfer Tool (or PttMain.exe)"
are added to the "Program or port" list as shown in the following
figure.

- 132 -
B-63344EN/02 APPENDIX B.Windows Firewall Settings

B.3 In Case of Using Windows Vista

Set the Windows Firewall as the following procedure.

(1) Open the "Control Panel", and click the "Allow a program through
Windows Firewall" of the "Security".

(2) In "General" tab, confirm that "On (recommended)" is checked


and "Block all incoming connections" is not checked.

- 133 -
B.Windows Firewall Settings APPENDIX B-63344EN/02

(3) Click "Exceptions" tab, and confirm "Notify me when Windows


Firewall blocks a new program" is checked.
Next, click the <Add program> button.

- 134 -
B-63344EN/02 APPENDIX B.Windows Firewall Settings

(4) There is the "Program Transfer Tool" on the "Add a Program"


screen. After selecting it, click the <OK> button.

When there is not "Program Transfer Tool", click the "Browse"


button. Display the "Bin" folder under the folder where you
install Program Transfer Tool. Then select the "PttMain.exe"
and click the <Open> button. Since the "Add a Program" screen
is displayed again, select the "PttMain.exe" and click the <OK>
button.

- 135 -
B.Windows Firewall Settings APPENDIX B-63344EN/02

(5) Confirm that the "Program Transfer Tool (or PttMain.exe)" was
added to the "Program or port" list as shown in the following
figure.

- 136 -
B-63344EN/02 APPENDIX B.Windows Firewall Settings

(6) Add "FethDgn.exe" to the "Exceptions" by above procedures.


In the procedure (4), select "Ethernet communication test" instead
of "Program Transfer Tool" and "FethDgn.exe" instead of
"PttMain.exe".
Then confirm that the "Ethernet communication test (or
FethDgn.exe)" and the "Program Transfer Tool (or PttMain.exe)"
are added to the "Program or port" list as shown in the following
figure.

- 137 -
B-64344EN/02 INDEX

INDEX
<C> <I>
Changing the Display of the PC Side Current Management In Case of Using Windows 2000 Service Pack 4 ..........127
Folder .............................................................................. 68 In Case of Using Windows Vista ..................................133
Changing the method of display..................... 69,81,98,105 In Case of Using Windows XP Service Pack 2 .............127
Changing the order of display ............................. 70,81,105 INSTALLATION.......................................................23,24
Changing the path of the CNC under communication..... 82
<L>
CNC ................................................................................ 13
Listing Tab ....................................................................118
Communication Tab...................................................... 120
Confirming Communication Settings......................... 46,52 <M>
CONNECTION TO A CNC............................................ 10 MACHINE INFO.TAB ...................................................42
Copying a file.................................................................. 72 MAINTENANCE OF SETTINGS..................................59
Creating a new folder .......................................... 76,94,117 MENU.............................................................................60
Menu and Toolbar ...........................................................65
<D>
Moving a file ...................................................................73
DEFINITION OF WARNING, CAUTION, AND
NOTE............................................................................. s-2 <O>
Deleting a file or folder ....................................... 75,92,116 OPERATING ENVIRONMENT ....................................12
DISPLAY........................................................................ 57 Operating Files and Folders in the Program Memory .....92
Display of a Data List ..................................................... 96 Operating Files and Folders on the Data Server............116
Display of a List of Files on the Data Server ................ 103 Operating Files and Folders on the PC............................71
Display of a List of Programs in the Program Memory .. 77 OPERATION ..................................................................63
Display of the Lower Screen (Connection Destination OPERATION ON FILES ON THE PC...........................11
Information) .................................................................... 67 OUTLINE OF THIS MANUAL .......................................3
Display of the Upper Screen (PC Information) ............... 66
<P>
Downloading from the PC to the CNC.......................... 101
PC FILE LIST OPERATION..........................................68
Downloading from the PC to the data server ................ 110
PERSONAL COMPUTER/HARDWARE......................17
Downloading from the PC to the program memory ........ 87
PERSONAL COMPUTER/SOFTWARE .......................18
<E> PREPARATION .............................................................24
Editing a file.................................................................... 72 PROGRAM TRANSFER TO AND FROM A DATA
SERVER .........................................................................11
<F>
PROGRAM TRANSFER TO AND FROM THE
File Transfer to and from the Data Server..................... 106
PROGRAM MEMORY ..................................................10
FILE TRANSFER TO AND FROM THE DATA
SERVER ....................................................................... 103 <R>
File Transfer to and from the Program Memory ............. 83 Renaming a file or folder .................................... 76,93,117
FILE TRANSFER TO AND FROM THE PROGRAM
<S>
MEMORY....................................................................... 77
SAFETY PRECAUTIONS ............................................ s-1
FUNCTION OVERVIEW ................................................9
SCREEN CONFIGURATION OF THE PROGRAM
<G> TRANSFER TOOL.........................................................64
GENERAL WARNINGS AND CAUTIONS ................ s-3 SERIAL NUMBER.........................................................41
SETTING ........................................................................39

i-1
INDEX B-64344EN/02

SETTING COMMUNICATION WITH DATA


SERVER ......................................................................... 50
SETTING COMMUNICATION WITH PROGRAM
MEMORY....................................................................... 44
SETTING OF OPTIONS .............................................. 118
SETTING OF THE CNC .............................................. 123
STARTING THE TOOL................................................. 64

<T>
TRANSFER OF DATA OTHER THAN PROGRAMS.. 95

<U>
UNINSTALLATION ...................................................... 32
Updating the display ....................................................... 70
UPGRADE INSTALLATION ........................................ 28
Uploading from the CNC to the PC ................................ 99
Uploading from the data server to the PC ..................... 106
Uploading from the program memory to the PC ............. 83

<V>
View, Edit Tab .............................................................. 119
Viewing a file.................................................................. 71

<W>
WARNINGS AND NOTES RELATING TO THE
PROGRAM TRANSFER TOOL ................................... s-5
Windows Firewall Settings ........................................... 126

i-2
Revision Record
FANUC PROGRAM TRANSFER TOOL OPERATOR'S MANUAL (B-64344EN)

- Applicable to Version 3.0


- Reflected the contents of the technical report for the
02 Jun., 2008 operator’s manual Version 01
- Applied to Series 0i -D

01 Sep., 2007

Edition Date Contents Edition Date Contents


FANUC PROGRAM TRANSFER TOOL OPERATOR'S MANUAL
The function to transfer data related to the tool management
of Series 30i /31i /32i - MODEL A

1.Type of applied technical documents

Name FANUC PROGRAM TRANSFER TOOL OPERATOR'S MANUAL

Spec.No./Ed. B-64344EN/02

2.Summary of Change

New
Add Applicable
Group Name/Outline
Correct Date
Delete

Basic The following function was added. Add Immediately


Function ・ The function to transfer data related to the tool
management of Series 30i /31i /32i - MODEL A

Optional
Function

Unit

Maintenance
Parts

Notice Applied Version:


・ A08B-9510-J513 Version 4.0 or later
・ A08B-9510-J514 Version 4.0 or later
Confirm followings in this document:
・ Applied software of Series 30i /31i /32i - MODEL A (Page 4)
・ Applied software of FAST Ethernet board / FAST Data Server board
(Page 4)
Correction

Another

TITLE: FANUC PROGRAM TRANSFER


TOOL OPERATOR’S MANUAL

01 08.10.09 Ogawa Newly registered DRAW.NO. B-64344EN/02-1

EDIT DATE DESIGN DESCRIPTION FANUC LTD. SHEET 1/10


We updated "FANUC Program Transfer Tool".

1. Version number
Old version New version
3.0 4.0

2. Ordering information
Software Drawing number
Program Transfer Tool CD A08B-9510-J513
Program Transfer Tool Upgrade CD A08B-9510-J514
*Upgrade CD is used to update the Program Transfer Tool of the old version to the latest version.

3. Contents of the change


- The function to transfer data related to the tool management
The function to transfer data related to the tool management of Series 30i /31i /32i - MODEL A has been
added.
See the following "FANUC PROGRAM TRANSFER TOOL OPERATOR'S MANUAL" for details.

TITLE: FANUC PROGRAM TRANSFER


TOOL OPERATOR’S MANUAL

01 08.10.09 Ogawa Newly registered DRAW.NO. B-64344EN/02-1

EDIT DATE DESIGN DESCRIPTION FANUC LTD. SHEET 2/10


FANUC PROGRAM TRANSFER TOOL OPERATOR'S MANUAL

The function to transfer data related to the tool management


The function to transfer the following data related to the tool management
of Series 30i /31i /32i - MODEL A has been added.

No. Data type


1 Tool management data
2 Magazine data
3 Tool life status name data
4 Name data of customize data
5 Customize data displayed as tool management data
6 Spindle waiting position name data
7 Decimal point position data of customize data
8 Tool geometry data
9 Tool geometry size data

This manual is a supplementary manual for the above-mentioned function.


Other explanations (existing functions, operation, etc.) are described in the
following manual.

Name of Manual Spec.No.


FANUC PROGRAM TRANSFER TOOL B-64344EN
OPERATOR'S MANUAL

TITLE: FANUC PROGRAM TRANSFER


TOOL OPERATOR’S MANUAL

01 08.10.09 Ogawa Newly registered DRAW.NO. B-64344EN/02-1

EDIT DATE DESIGN DESCRIPTION FANUC LTD. SHEET 3/10


1 Outline
The function to transfer data related to the tool management has been added
to the Program Transfer Tool.

1.1 Applied Software

The function to transfer data related to the tool management can be used
with the following version of Program Transfer Tool.
Software Drawing number Edition
Program Transfer Tool CD A08B-9510-J513
4.0
Program Transfer Tool Upgrade CD A08B-9510-J514

This function can be used with Series 30i /31i /32i - MODEL A.
The following software series and edition is necessary.
Software Series Edition
G00C, G01C, G02C
32.0
Series 30i /300i /300is - MODEL A G003, G013, G023
CNC System Software G00B, G01B, G02B
49.0
G002, G012, G022
Series 31i /310i /310is - MODEL A G103, G113 32.0
CNC System Software G101, G111 49.0
G12C, G13C
32.0
Series 31i /310i /310is - MODEL A5 G123, G133
CNC System Software G12B, G13B
49.0
G121, G131
Series 32i /320i /320is - MODEL A G203 32.0
CNC System Software G201 49.0

To use FAST Ethernet board or FAST Data Server board, the following
software series and edition is necessary.
Software Drawing number Edition
Control software for
FAST Ethernet board / A02B-0303-J561#6569 24
FAST Data Server board

TITLE: FANUC PROGRAM TRANSFER


TOOL OPERATOR’S MANUAL

01 08.10.09 Ogawa Newly registered DRAW.NO. B-64344EN/02-1

EDIT DATE DESIGN DESCRIPTION FANUC LTD. SHEET 4/10


1.2 Data can be transferred

Since the function to transfer data related to the tool management was added,
this tool could transfer the following data. (The masked area shows
additional data in this version 4.0)

Table 1 Data can be transferred


Data
management type
No Data type File name *2 for path: Remarks
Common /
Each path
1 Tool management data *1 TOOL_MNG.TXT
2 Magazine data *1 *3 MAGAZINE.TXT
3 Tool life status name data STATUS.TXT
4 Name data of customize data *3 CUSTOMIZ.TXT
Additional
Customize data displayed as tool management Common
5 DISPCSTM.TXT data in this
data version 4.0
6 Spindle waiting position name data POSNAME.TXT
7 Decimal point position data of customize data POINTPOS.TXT
8 Tool geometry data TOOLGEOM.TXT
9 Tool geometry size data TOOLSIZE.TXT Each path
10 Tool offsets TOOLOFST.TXT
Already
11 Custom macros MACRO.TXT Each path
available
12 Workpiece origin offsets EXT_WKZ.TXT

*1 The tool management data and the magazine data not only can be
transferred but also can be deleted.
*2 The file name has been basically decided for each data. The file names of
the description are the following data.
- A data which is not managed for each path by CNC
- The 1st path data which is managed for each path by CNC
These file name is the same as given when data is output to a memory
card without specifying a file name.
For data of a second or subsequent path, the extension "P-path-number"
is used. However, for the 10th path, the extension is "P10" without "-".
Example:
Tool geometry size data of the 1st path: TOOLSIZE.TXT
Tool geometry size data of the 2nd path: TOOLSIZE.P-2
Tool geometry size data of the 10th path: TOOLSIZE.P10
These file name is the same as given when bit 0 of parameter No. 138 is
set to 1 on the CNC and data is output to a memory card without
specifying a file name.
*3 When FAST Ethernet board / FAST Data Server board is used, the name
data of customize data and the magazine data cannot be downloaded.

TITLE: FANUC PROGRAM TRANSFER


TOOL OPERATOR’S MANUAL

01 08.10.09 Ogawa Newly registered DRAW.NO. B-64344EN/02-1

EDIT DATE DESIGN DESCRIPTION FANUC LTD. SHEET 5/10


1.3 Displaying of data List

When this tool connects to the CNC program memory, filenames in the
"Table 1 Data can be transferred" of "1.2 Data can be transferred" will be
displayed on the file list of the "[DATA]" folder. Data is not displayed on
the screen when the option is not in CNC though the CNC option is
necessary for data.
Following icons are used for displaying the data related to the tool
management as well as the tool offset data, etc.
Large List/Detail

When displaying data in detail, "Type" and "Path No." besides "File name"
are displayed as shown in the figure below.

Example: Displaying detail data list of 2 path CNC

A path number of data is displayed in the "Path No." in case of a data


managed for each path by CNC.
"1" is displayed in the "Path No." in case of a data not managed for each
path by CNC.

TITLE: FANUC PROGRAM TRANSFER


TOOL OPERATOR’S MANUAL

01 08.10.09 Ogawa Newly registered DRAW.NO. B-64344EN/02-1

EDIT DATE DESIGN DESCRIPTION FANUC LTD. SHEET 6/10


1.4 Operation of screen

Both types of data transferring, Upload (from CNC to PC) and Download
(from PC to CNC), are available.
The tool management data and the magazine data in CNC not only can be
transferred but also can be deleted.

1.4.1 Upload (Transferring from CNC to PC)

Data in the "Table 1 Data can be transferred" of "1.2 Data can be


transferred" can be uploaded.
The data type of selected data in the screen will be displayed in the "Data
Type" field of the "Upload CNC Data" dialog.

1.4.2 Download (Transferring from PC to CNC)

Data in the "Table 1 Data can be transferred" of "1.2 Data can be


transferred" can be downloaded.
If the selected file name is same as the format of "Table 1 Data can be
transferred", the downloaded data type and path number are automatically
selected.
If the selected file name is different from the format of "Table 1 Data can be
transferred", it is necessary to select the downloaded data type and path
number on the "Update CNC Data" dialog.

TITLE: FANUC PROGRAM TRANSFER


TOOL OPERATOR’S MANUAL

01 08.10.09 Ogawa Newly registered DRAW.NO. B-64344EN/02-1

EDIT DATE DESIGN DESCRIPTION FANUC LTD. SHEET 7/10


Note
1. The alarm might be generated by CNC though download
ends normally. Confirm the CNC state and the
downloaded data is correctly set to CNC.
2. A data that is managed for each path by CNC can be
downloaded by changing the path number.
Example: The tool geometry size data in the 1st path
can be downloaded to the 2nd path.
3. When the customize data displayed as tool management
data (DISPCSTM.TXT) or the decimal point position data
of customize data (POINTPOS.TXT) was downloaded,
CNC should be restart.
4. When FAST Ethernet board / FAST Data Server board is
used, the name data of customize data (CUSTOMIZ.TXT)
and the magazine data (MAGAZINE.TXT) cannot be
downloaded.

TITLE: FANUC PROGRAM TRANSFER


TOOL OPERATOR’S MANUAL

01 08.10.09 Ogawa Newly registered DRAW.NO. B-64344EN/02-1

EDIT DATE DESIGN DESCRIPTION FANUC LTD. SHEET 8/10


When the tool management function for oversize tools has been used on
CNC, keep the following in mind.
Note
1. If a target tool is registered in a magazine and interferes
with other tools in registration or modification of the tool
geometry data of the tool management data, alarm
PS5360 is issued. (The data is not input.)
Correct interference with other tools.
2. If a tool interferes with other tools in registration or
modification to the magazine management table, alarm
PS5360 is issued. (The data is not input.)
Correct interference with other tools.
3. If an attempt is made to modify the tool geometry data,
and the tool for which the tool geometry data number
subject to modification is set is registered in the magazine,
alarm PS5360 is issued. (The data is not input.)
Delete the magazine data before downloading.
4. When the tool geometry data (TOOLGEOM.TXT), the tool
management data (TOOL_MNG.TXT), and the magazine
data (MAGAZINE.TXT) in CNC are deleted, and these
data are downloaded again, these data should be
downloaded by the following procedure:
(a) When the data file for downloading is specified one by
one:
These data should be specified in order of the tool
geometry data, the tool management data, and the
magazine data.
(b) When plural data files for downloading are specified at
the same time:
This tool downloads data in order as (a).

TITLE: FANUC PROGRAM TRANSFER


TOOL OPERATOR’S MANUAL

01 08.10.09 Ogawa Newly registered DRAW.NO. B-64344EN/02-1

EDIT DATE DESIGN DESCRIPTION FANUC LTD. SHEET 9/10


1.4.3 Deleteing a data in CNC (Tool management data and magazine data)

When the tool management data, the magazine data, and the tool geometry
data are downloaded to CNC which has these data, the data might not be
changed by the interference with tools etc. In this case, delete the tool
management data or the magazine data in CNC before downloading with this
tool.

To delete the tool management data or the magazine data:


- Select the tool management data (TOOL_MNG.TXT) or the magazine
data (MAGAZINE.TXT) in the file list of the [DATA] folder.
- Then, operate one of the following deletion operations.
- Click the [Delete] command on the [Communication] menu.
- Click the [Delete] command on the context menu displayed by
right-clicking a selected file.
- Press the [Delete] key.

Note
1. When deletion operations are operated for the icon of the
tool management data or the magazine data, the data in
CNC is deleted. But the icon on the screen remains being
displayed.
2. When the tool management data (TOOL_MNG.TXT) has
been selected, the magazine data is deleted together.
(Only the tool management data cannot be deleted.)

3. When the plural data have been selected, the data cannot
be deleted even if the tool management data or the
magazine data has been selected.

TITLE: FANUC PROGRAM TRANSFER


TOOL OPERATOR’S MANUAL

01 08.10.09 Ogawa Newly registered DRAW.NO. B-64344EN/02-1

EDIT DATE DESIGN DESCRIPTION FANUC LTD. SHEET 10/10


FANUC PROGRAM TRANSFER TOOL
The additional explanation about Windows 7 support

1.Type of applied technical documents

Name FANUC PROGRAM TRANSFER TOOL OPERATOR'S MANUAL

Spec.No./Ed. B-64344EN/02

2.Summary of Change

New
Add Applicable
Group Name/Outline
Correct Date
Delete

Basic The following function was added. Add Immediately


Function ・ Windows 7 has been supported.

Optional
Function

Unit

Maintenance
Parts

Notice Applied Version:


・ A08B-9510-J513 Version 5.0 or later
・ A08B-9510-J514 Version 5.0 or later
Correction

Another

TITLE: FANUC PROGRAM TRANSFER TOOL


The additional explanation about
Windows 7 support

01 10.04.13 Matsukura Newly registered DRAW.NO. B-64344EN/02-2

EDIT DATE DESIGN DESCRIPTION FANUC LTD. SHEET 1/11


We updated "FANUC Program Transfer Tool".

1. Version number
Old version New version
4.0 5.0

2. Ordering information
Software Drawing number
Program Transfer Tool CD A08B-9510-J513
Program Transfer Tool Upgrade CD A08B-9510-J514
*Upgrade CD is used to update the Program Transfer Tool of the old version to the latest version.

3. Contents of the change


- Windows 7 support
Applied to Windows 7 Professional (32bit OS) English, Japanese, and Simplified Chinese.

TITLE: FANUC PROGRAM TRANSFER TOOL


The additional explanation about
Windows 7 support

01 10.04.13 Matsukura Newly registered DRAW.NO. B-64344EN/02-2

EDIT DATE DESIGN DESCRIPTION FANUC LTD. SHEET 2/11


Please replace the section "3.3 PERSONAL COMPUTER/SOFTWARE" of "I. GENERAL" by
the following explanation.

3.3 PERSONAL COMPUTER/SOFTWARE

When the OS is Windows 7


(1) and (2) below are required:
(1) Microsoft Windows 7® Professional (32 bit version OS)
(2) Microsoft Internet Explorer 8.0 or later

NOTE
1 To do the following operations of this tool on Windows 7, the user must belong to the
Administrators group.
a) Installation
b) Uninstallation
c) Upgrade installation
2 This tool does not support the user switching function of Windows 7.

When the OS is Windows Vista


(1) and (2) below are required:
(1) Microsoft Windows Vista® Business Service Pack 2 or later (32 bit version OS)
(2) Microsoft Internet Explorer 7.0 or later

NOTE
1 To do the following operations of this tool on Windows Vista, the user must belong to the
Administrators group.
a) Installation
b) Uninstallation
c) Upgrade installation
2 This tool does not support the user switching function of Windows Vista.

TITLE: FANUC PROGRAM TRANSFER TOOL


The additional explanation about
Windows 7 support

01 10.04.13 Matsukura Newly registered DRAW.NO. B-64344EN/02-2

EDIT DATE DESIGN DESCRIPTION FANUC LTD. SHEET 3/11


When the OS is Windows XP
(1) and (2) below are required:
(1) Microsoft Windows XP® Professional Service Pack 3 or later (32 bit version OS)
(2) Microsoft Internet Explorer 6.0 or later

NOTE
1 To use this tool on Windows XP, the user must belong to the Administrators group.
2 Only the user who has installed this tool can use this tool.
This tool does not support the user switching function of Windows XP.

When the OS is Windows 2000


(1) and (2) below are required:
(1) Microsoft Windows 2000® Professional ServicePack 4 or later
(2) Microsoft Internet Explorer 6.0 or later

NOTE
1 To use this tool on Windows 2000, the user must belong to the Administrators group.
2 Only the user who has installed this tool can use this tool.

Supported Language
English, Japanese, and Simplified Chinese

The language displayed with this tool is automatically selected according to the language of OS when you install
this tool.
English will be selected if this tool is installed in OSs other than the language of the above.

TITLE: FANUC PROGRAM TRANSFER TOOL


The additional explanation about
Windows 7 support

01 10.04.13 Matsukura Newly registered DRAW.NO. B-64344EN/02-2

EDIT DATE DESIGN DESCRIPTION FANUC LTD. SHEET 4/11


Please replace the section "B Windows Firewall Settings" of "B. APPENDIX" by the following
explanation.

A
B Windows Firewall Settings
It is necessary to set the Windows Firewall to communicate with DATA SERVER or FTP server with some of
Windows OS. However, if you don't communicate with DATA SERVER or FTP server, the following setting is
not necessary.

CAUTION
The setting as described below changes the network security. Therefore, before you change
the settings as described below, consult with your network administrator, and take special
care.
When the communication of an existing program is carelessly permitted, the loss of the
network security might be caused.

TITLE: FANUC PROGRAM TRANSFER TOOL


The additional explanation about
Windows 7 support

01 10.04.13 Matsukura Newly registered DRAW.NO. B-64344EN/02-2

EDIT DATE DESIGN DESCRIPTION FANUC LTD. SHEET 5/11


Please add the following explanation to the section "B.4 In Case of Using Windows 7" of "B.
APPENDIX"

B.4 In Case of Using Windows 7

Set the Windows Firewall as the following procedure.


First, write down the "Active network" type in the "View your active networks" with procedure from (1) to (3).
Then, setup Windows Firewall to communicate programs of the Program Transfer Tool in the "Active network"
with procedure from (4) to (9).

(1) Open the "Control panel" and click the "Network and Internet".

(2) Click the Network and Sharing Center.

TITLE: FANUC PROGRAM TRANSFER TOOL


The additional explanation about
Windows 7 support

01 10.04.13 Matsukura Newly registered DRAW.NO. B-64344EN/02-2

EDIT DATE DESIGN DESCRIPTION FANUC LTD. SHEET 6/11


(3) Write down the network type displayed in the "View your active networks".
This will be used at procedure (9).

The "View your activate networks" will shows "Home network", "Work network", "Public network", or
"Domain network".

TITLE: FANUC PROGRAM TRANSFER TOOL


The additional explanation about
Windows 7 support

01 10.04.13 Matsukura Newly registered DRAW.NO. B-64344EN/02-2

EDIT DATE DESIGN DESCRIPTION FANUC LTD. SHEET 7/11


(4) Open the "Control panel" and click the "System and Security".

(5) Click the "Allow a program through Windows Firewall".

TITLE: FANUC PROGRAM TRANSFER TOOL


The additional explanation about
Windows 7 support

01 10.04.13 Matsukura Newly registered DRAW.NO. B-64344EN/02-2

EDIT DATE DESIGN DESCRIPTION FANUC LTD. SHEET 8/11


(6) Click the "Change settings".

(7) Click the "Allow another program...".

TITLE: FANUC PROGRAM TRANSFER TOOL


The additional explanation about
Windows 7 support

01 10.04.13 Matsukura Newly registered DRAW.NO. B-64344EN/02-2

EDIT DATE DESIGN DESCRIPTION FANUC LTD. SHEET 9/11


(8) Select the "Program Transfer Tool" and click the "Add". Then, select the "Ethernet communication test" and
click the "Add".
If the "Program Transfer Tool" or the "Ethernet communication test" is not displayed, click the "Browse..."
and find them.

The "Program Transfer Tool" and the "Ethernet communication test" are stored the Bin folder under the
folder that installs the Program Transfer Tool.

Ethernet communication test

Program Transfer Tool

TITLE: FANUC PROGRAM TRANSFER TOOL


The additional explanation about
Windows 7 support

01 10.04.13 Matsukura Newly registered DRAW.NO. B-64344EN/02-2

EDIT DATE DESIGN DESCRIPTION FANUC LTD. SHEET 10/11


(9) Set network features according to "Active network" written down in procedure (3).

"Active network" value Network features


Home network
Home/Work (Private)
Work network
Public network Public
Domain network Domain

The figure below is an example of setting for "Work network" according to the display of procedure (3).

TITLE: FANUC PROGRAM TRANSFER TOOL


The additional explanation about
Windows 7 support

01 10.04.13 Matsukura Newly registered DRAW.NO. B-64344EN/02-2

EDIT DATE DESIGN DESCRIPTION FANUC LTD. SHEET 11/11


FANUC PROGRAM TRANSFER TOOL OPERATOR'S MANUAL
Additional explanation about Series 0i - PD support

1. Type of applied technical documents

FANUC PROGRAM TRANSFER TOOL


Name
OPERATOR'S MANUAL

Spec.No. /Version B-64344EN/02

2. Summary of change

New, Add,
Applicable
Group Name / Outline Correct,
Date
Delete
The following function were added.
Basic Series 0i - PD has been supported.
Add Immediately
Function Windows 7 Professional 64 bit OS
has been supported.
Optional
Function

Unit

Maintenance
parts
Applied Version:
Notice A08B-9510-J513 Version 7.0 or later
A08B-9510-J514 Version 7.0 or later

Correction

Another

TITLE FANUC PROGRAM TRANSFER TOOL


ADDITIONAL OPERATOR’S MANUAL
Additional explanation about Series 0i-PD
support
DRAW. NO. CUST.
01 '11.03.07 Matsukura New Issue B-64344EN/02-4
SHEET
EDIT. DATE DESIG. DESCRIPTION 1/3
"FANUC Program Transfer Tool" has been updated.

1. Version number

Old version New version


6.0 7.0

2. Ordering information

Software Drawing number


Program Transfer Tool CD A08B-9510-J513
Program Transfer Tool Upgrade CD A08B-9510-J514

*Upgrade CD is used to update the Program Transfer Tool of the old version to the latest version.

3. Contents of the change


Series 0i-PD has been supported.
Windows 7 Professional 64bit OS has been supported.

TITLE FANUC PROGRAM TRANSFER TOOL


ADDITIONAL OPERATOR’S MANUAL
Additional explanation about Series 0i-PD
support
DRAW. NO. CUST.
01 '11.03.07 Matsukura New Issue B-64344EN/02-4
SHEET
EDIT. DATE DESIG. DESCRIPTION 2/3
Add the the following underlined explanation to the No.36 of the "Ethernet board or
data server board and required CNC options (3/3)" table in the "3.1 CNC" of "I.
GENERAL".

Ethernet board or data server board and required CNC options (3/3)
Applicable Control
No Name Drawing number CNC option
model software
Fast Ethernet for A02B-XXXX-S707
LCD-mounted type/ FS 0i-TD/MD *1 A02B-0319-J561
36 A02B-0319-J146
stand-alone type FS 0i-PD A02B-XXXX-S737 #658W
CNC *3

XXXX specifies a drawing number according to the CNC type as follows:


0319 (0i-TD), 0320 (0i-MD, 0i-PD)

Add the following underlined explanation to the "(3) CNC Type" in the "1.2 MACHINE
INFO.TAB" of "III.SETTING".

(3) CNC Type


Select the type of the CNC.
Select the "Series 0i-D" for FS 0i-TD, 0i-MD, and 0i-PD.

Please add the following explanation to the section "3.3 PERSONAL


COMPUTER/SOFTWARE" of "I. GENERAL".

3.3 PERSONAL COMPUTER/SOFTWARE


When the OS is Windows 7
(1) and (2) below are required:
(1) Microsoft Windows 7® Professional (32 bit OS or 64 bit OS)
(2) Microsoft Internet Explorer 8.0 or later

NOTE
1 To do the following operations of this tool on Windows 7, the user must
belong to the Administrators group.
a) Installation
b) Uninstallation
c) Upgrade installation
2 This tool does not support the user switching function of Windows 7.

TITLE FANUC PROGRAM TRANSFER TOOL


ADDITIONAL OPERATOR’S MANUAL
Additional explanation about Series 0i-PD
support
DRAW. NO. CUST.
01 '11.03.07 Matsukura New Issue B-64344EN/02-4
SHEET
EDIT. DATE DESIG. DESCRIPTION 3/3
FANUC PROGRAM TRANSFER TOOL OPERATOR'S MANUAL
Additional explanation about Series 30i /31i /32i /35i - MODEL B support

1.Type of applied technical documents

Name FANUC PROGRAM TRANSFER TOOL OPERATOR'S MANUAL

Spec.No./Ed. B-64344EN/02

2.Summary of Change

New
Add Applicable
Group Name/Outline
Correct Date
Delete

Basic The following function was added. Add Immediately


Function ・Series 30i /31i /32i /35i - MODEL B has been
supported.

Optional
Function

Unit

Maintenance
Parts

Notice Applied Version:


・A08B-9510-J513 Version 6.0 or later
・A08B-9510-J514 Version 6.0 or later
Correction

Another

TITLE: FANUC PROGRAM TRANSFER TOOL


ADDITIONAL OPERATOR’S MANUAL

01 2010.10.13 Matsukura Newly registered DRAW.NO. B-64344EN/02-3

EDIT DATE DESIGN DESCRIPTION FANUC LTD. SHEET 1/8


"FANUC Program Transfer Tool" has been updated.

1. Version number
Old version New version
5.1 6.0

2. Ordering information
Software Drawing number
Program Transfer Tool CD A08B-9510-J513
Program Transfer Tool Upgrade CD A08B-9510-J514
*Upgrade CD is used to update the Program Transfer Tool of the old version to the latest version.

3. Contents of the change


Series 30i /31i /32i /35i -B, Series 30i /31i -LB, Series 30i /31i -PB has been supported.

TITLE: FANUC PROGRAM TRANSFER TOOL


ADDITIONAL OPERATOR’S MANUAL

01 2010.10.13 Matsukura Newly registered DRAW.NO. B-64344EN/02-3

EDIT DATE DESIGN DESCRIPTION FANUC LTD. SHEET 2/8


Replace the "Related manuals of Ethernet board" in the "I.GENERAL 1.OUTLINE OF THIS
MANUAL" to the following explanation.

Related manuals of Ethernet board


Manual name Specification number
FANUC Series 30i-MODEL A/B FANUC Series 31i-MODEL A/B
FANUC Series 32i-MODEL A/B FANUC Series 35i-MODEL B B-64014EN
Fast Ethernet / Fast Data Server OPERATOR’S MANUAL
Fast Ethernet Board / Fast Data Server OPERATOR’S MANUAL B-63644EN
Ethernet Board / Data Server Board OPERATOR’S MANUAL B-63354EN

Add the following explanation to the "Related manuals" in the "I.GENERAL 1.OUTLINE OF THIS
MANUAL".

Related manuals of FANUC Series 30i/ 31i/ 32i MODEL-B


Manual name Specification number
DESCRIPTIONS B-64482EN
CONNECTION MANUAL (HARDWARE) B-64483EN
CONNECTION MANUAL (FUNCTION) B-64483EN-1
USER’S MANUAL (Common to Lathe System/Machining Center System) B-64484EN
USER’S MANUAL (For Lathe System) B-64484EN-1
USER’S MANUAL (For Machining Center System) B-64484EN-2
MAINTENANCE MANUAL B-64485EN
PARAMETER MANUAL B-64490EN

Related manuals of FANUC Series 35i MODEL-B


Manual name Specification number
DESCRIPTIONS B-64522EN
CONNECTION MANUAL (HARDWARE) B-64523EN
CONNECTION MANUAL (FUNCTION) B-64523EN-1
USER’S MANUAL B-64524EN
MAINTENANCE MANUAL B-64525EN
PARAMETER MANUAL B-64530EN

TITLE: FANUC PROGRAM TRANSFER TOOL


ADDITIONAL OPERATOR’S MANUAL

01 2010.10.13 Matsukura Newly registered DRAW.NO. B-64344EN/02-3

EDIT DATE DESIGN DESCRIPTION FANUC LTD. SHEET 3/8


Add the following explanation to the "Ethernet devices and CNC options" table in the
"I. GENERAL 3. OPERATING ENVIRONMENT".

CNC option required for


CNC option required for
transferring files and
transferring files and
CNC type Ethernet device used non-program data to and
non-program data to and
from data server (FTP
from program memory
server setting required)
Series 30i /31i /32i-B Embedded Ethernet No option required
(Communication not
enabled)
Series 31i-B5
(Communication not
Series 35i-B (*2) Muti-function Ethernet (*3) Ethernet functions
enabled)
Series 30i /31i-LB
Fast Ethernet board Ethernet functions Data Server functions(*2)
Series 30i /31i-PB

*2 Data server function cannot use on Series 35i-B.


*3 Main board which supported Multi-function Ethernet function is required.

Add the following explanation to the "Ethernet board or data server board and required CNC
options (3/3)" table in the "I. GENERAL 3. OPERATING ENVIRONMENT".

Ethernet board or data server board and required CNC options (3/3)
No Name Applicable model Drawing number CNC option Control software
FS 30i/31i/32i/35i-B
Embedded Ethernet for
FS 31i-B5 A02B-0323-J571
37 LCD-mounted type/ ― Not required
FS 30i/31i-LB #658M
stand-alone type CNC
FS 30i/31i-PB
A02B-XXXX-H102
A02B-XXXX-H213
FS 30i/31i/32i-B A02B-XXXX-H211
FS 31i-B5 A02B-XXXX-H215
A02B-XXXX-H216
Multi-function Ethernet for A02B-0323-J561
38 A02B-XXXX-H217 A02B-XXXX-S707
LCD-mounted type CNC #658K
FS 35i-B A02B-XXXX-H102
A02B-XXXX-H102
FS 30i/31i-LB A02B-XXXX-H211
FS 30i/31i-PB A02B-XXXX-H215
A02B-XXXX-H217
FS 30i/31i/32i A02B-XXXX-S707
FS 31i-B5 * 16
Fast Ethernet for
FS 30i/31i-LB A02B-0323-J147 A02B-XXXX-S737 A02B-0323-J561
39 LCD-mounted type/
FS 30i/31i-PB * 17 * 17 #658K
stand-alone type CNC
A02B-XXXX-S707
FS 35i-B
* 16

TITLE: FANUC PROGRAM TRANSFER TOOL


ADDITIONAL OPERATOR’S MANUAL

01 2010.10.13 Matsukura Newly registered DRAW.NO. B-64344EN/02-3

EDIT DATE DESIGN DESCRIPTION FANUC LTD. SHEET 4/8


XXXX specifies a drawing number according to the CNC type as follows:
0323(30i-B,30i-LB,30i-PB), 0326(31i-B5), 0327(31i-B,31i-LB,31i-PB), 0328(32i-B), 0333(35i-B)

* 16 A02B-XXXX-S707:Ethernet function
This option is required when this tool transfers programs in CNC program memory.

* 17 A02B-XXXX-S737:Data server function


This option is required when this tool transfers programs in Data server.
Data server function cannot be used on Series 31i-B5.

Replace the "(3) CNC Type" in the "III.SETTING 1.2 MACHINE INFO.TAB" to the following
explanation.
(3) CNC Type
Select the type of the CNC.
See the following table to setting CNC type for Series 3Xi-A/B
CNC Value for the CNC Type
Series 30i-A/B、Series 30i-LB、Series 30i-PB Series 30
Series 31i-A/B、Series 31i-A5/B5、Series 31i-LB、Series 31i-PB Series 31
Series 32i-A/B Series 32
Series 35i-B Series 35

NOTE
If the type of the CNC selected and the type of the CNC connected are different, it is not
possible to use this tool.

Replace the "File list" table in the "IV.OPERATION 1.2.2 Display of the Upper Screen (PC
Information)" to the following explanation.

Custom macro Workpiece origin


CNC Tool offset
variable offset
Series 30i/31i/32i-A
Series 31i-A5
Series 30i/31i/32i/35i-B
Series 31i-B5 TOOLOFST.TXT MACRO.TXT EXT_WKZ.TXT
Series 30i/31i-LB
Series 30i/31i-PB
Series 0i-D
Series 16i/18i/21i-A/B
Series 0i-B/C TOOLOFST.DAT MACROVAR.DAT WORK-G54.DAT
Series 20i-B
Power Mate i -D/H TOOLOFST.DAT MACROVAR.DAT None

TITLE: FANUC PROGRAM TRANSFER TOOL


ADDITIONAL OPERATOR’S MANUAL

01 2010.10.13 Matsukura Newly registered DRAW.NO. B-64344EN/02-3

EDIT DATE DESIGN DESCRIPTION FANUC LTD. SHEET 5/8


Replace the NOTE in the "IV.OPERATION 1.7.3 Communication Tab" to the following
explanation.

NOTE
Fast ethernet board with the following software edition, the data storage format can be set
using parameter No. 929, regardless of the transfer mode specification on the PC.
- Software edition of fast ethernet board:
For Series 30i /31i /32i -A :Series 6569 Edition 14 or later
For Series 0i -D :Series 658W Edition 01 or later
For Series 30i /31i /32i -B :Series 658K Edition 01 or later
- Parameter setting:
0: Data is stored according to the transfer mode specified on the PC (as conventionally
done).
1: Data is stored in the text format.
2: Data is stored in the binary format.
When using a data server with this parameter made valid, set the parameter above to 0 to
enable the transfer mode of this tool.

TITLE: FANUC PROGRAM TRANSFER TOOL


ADDITIONAL OPERATOR’S MANUAL

01 2010.10.13 Matsukura Newly registered DRAW.NO. B-64344EN/02-3

EDIT DATE DESIGN DESCRIPTION FANUC LTD. SHEET 6/8


Replace the "1.1 Applied Software" in the " ADDITIONAL INFORMATION B-64344EN/02-1" to
the following explanation.

1.1 Applied Software

Series 30i /31i /32i - MODEL A


The function to transfer data related to the tool management can be used with the following version of
Program Transfer Tool.
Software Drawing number Edition
Program Transfer Tool CD A08B-9510-J513
4.0
Program Transfer Tool Upgrade CD A08B-9510-J514

The following CNC System Software series and edition is necessary.


Software Series Edition
G004, G014, G024 01
Series 30i - MODEL A G00C, G01C, G02C, G003, G013, G023 32
G00B, G01B, G02B, G002, G012, G022 49
G124, G134 01
Series 31i - MODEL A5 G12C, G13C, G123, G133 32
G12B, G13B, G121, G131 49
G104, G114 01
Series 31i - MODEL A G103, G113 32
G101, G111 49
G204 01
Series 32i - MODEL A G203 32
G201 49

To use Fast Ethernet board or Fast Data Server board, the following software edition is necessary.
Software Drawing number Edition
Control software for Fast Ethernet
A02B-0303-J561#6569 24
board /Fast Data Server board

TITLE: FANUC PROGRAM TRANSFER TOOL


ADDITIONAL OPERATOR’S MANUAL

01 2010.10.13 Matsukura Newly registered DRAW.NO. B-64344EN/02-3

EDIT DATE DESIGN DESCRIPTION FANUC LTD. SHEET 7/8


Series 30i /31i /32i - MODEL B
The function to transfer data related to the tool management can be used with the following version of
Program Transfer Tool.
Software Drawing number Edition
Program Transfer Tool CD A08B-9510-J513
6.0
Program Transfer Tool Upgrade CD A08B-9510-J514

The following CNC System Software series and edition is necessary.


Software Series Edition
Series 30i - MODEL B G300, G310, G320 01
Series 31i - MODEL B5 G420, G430 01
Series 31i - MODEL B G400, G410 01
Series 32i - MODEL B G500 01

To use Fast Ethernet board or Fast Data Server board, the following software edition is necessary.
Software Drawing number Edition
Control software for
A02B-0323-J561#658K 01
Fast Ethernet function

TITLE: FANUC PROGRAM TRANSFER TOOL


ADDITIONAL OPERATOR’S MANUAL

01 2010.10.13 Matsukura Newly registered DRAW.NO. B-64344EN/02-3

EDIT DATE DESIGN DESCRIPTION FANUC LTD. SHEET 8/8


FANUC PROGRAM TRANSFER TOOL OPERATOR'S MANUAL
Additional explanation
Power Motion i - MODEL A support
Series 0i Mate - MODEL D support

1.Type of applied technical documents

Name FANUC PROGRAM TRANSFER TOOL OPERATOR'S MANUAL

Spec.No./Ed. B-64344EN/02

2.Summary of Change

New
Add Applicable
Group Name/Outline
Correct Date
Delete

Basic The following CNCs have been supported. Add Immediately


Function - Power Motion i - MODEL A
- Series 0i Mate- MODEL D
Optional
Function

Unit

Maintenance
Parts

Notice Applied Version:


- A08B-9510-J513 Version 8.0 or later
- A08B-9510-J514 Version 8.0 or later
Correction

Another

TITLE FANUC PROGRAM TRANSFER TOOL


OPERATOR’S MANUAL
Additional explanation
Power Motion i-A / Series 0i Mate-D support
DRAW. NO. CUST.
01 2011.08.12 Matsukura New Issue T.Hosaka B-64344EN/02-5
SHEET
EDIT. DATE DESIG. DESCRIPTION 1/4
"FANUC Program Transfer Tool" has been updated.

1. Version number

Old version New version

7.0 8.0

2. Ordering information

Software Drawing number

Program Transfer Tool CD A08B-9510-J513

Program Transfer Tool Upgrade CD A08B-9510-J514

*Upgrade CD is used to update the Program Transfer Tool of the old version to the latest version.

3. Contents of the change


The following CNC have been supported.
- Power Motion i - MODEL A
- Series 0i Mate - MODEL D

TITLE FANUC PROGRAM TRANSFER TOOL


OPERATOR’S MANUAL
Additional explanation
Power Motion i-A / Series 0i Mate-D support
DRAW. NO. CUST.
01 2011.08.12 Matsukura New Issue T.Hosaka B-64344EN/02-5
SHEET
EDIT. DATE DESIG. DESCRIPTION 2/4
Add the following explanation to the "Related manuals" in the
"I.GENERAL 1.OUTLINE OF THIS MANUAL".

Related manuals of FANUC Power Motion i -A


Manual name Specification number
DESCRIPTIONS B-64572EN
CONNECTION MANUAL (HARDWARE) B-64573EN
CONNECTION MANUAL (FUNCTION) B-64573EN-1
USER'S MANUAL B-64574EN
MAINTENANCE MANUAL B-64575EN
PARAMETER MANUAL B-64580EN

Add the following explanation to the "Ethernet devices and CNC options" table in
the "I. GENERAL 3. OPERATING ENVIRONMENT".

CNC option required for


CNC option required for
transferring files and
transferring files and
CNC type Ethernet device used non-program data to and
non-program data to and
from data server
from program memory
(FTP server setting required)

Embedded Ethernet No option required

Power Motion i-A Multi-function Ethernet (*4)


(Cannot be used)
Ethernet functions
(*6)
Fast Ethernet board

Series 0i Mate-D Embedded Ethernet (*5) No option required

*4 Main board with Multi-function Ethernet function is required.


*5 Main board with Embedded Ethernet function is required.
*6 Data server function cannot be used.

TITLE FANUC PROGRAM TRANSFER TOOL


OPERATOR’S MANUAL
Additional explanation
Power Motion i-A / Series 0i Mate-D support
DRAW. NO. CUST.
01 2011.08.12 Matsukura New Issue T.Hosaka B-64344EN/02-5
SHEET
EDIT. DATE DESIG. DESCRIPTION 3/4
Add the following explanation to the "Ethernet board or data server board and
required CNC options (3/3)" table in the "I. GENERAL 3. OPERATING ENVIRONMENT".

Ethernet board or data server board and required CNC options (3/3)
No Name Applicable model Drawing number CNC option Control software

Embedded Ethernet for


A02B-0334-J571
40 LCD-mounted type/ - Not required
#658M
stand-alone type CNC

A02B-0334-H102
Multi-function Ethernet for
41 Power Motion i-A or
LCD-mounted type CNC
A02B-0334-H211
A02B-0334-J561
A02B-0334-S707
Fast Ethernet for #658K
A02B-0323-J147
42 LCD-mounted type/
* 18
stand-alone type CNC
A02B-0319-H125
43 Embedded Ethernet Series 0i Mate-D Not required Not required
* 19

* 18 A02B-0323-J147: Embedded Ethernet for LCD-mounted type/stand-alone type CNC


Data server function cannot be used on Power Motion i-A.
* 19 A02B-0319-H125: Main board with Embedded Ethernet function.

Add the following underlined explanation to the "(3) CNC Type" in the
"III. SETTING 1.2 MACHINE INFO.TAB".

(3) CNC Type


Select the type of the CNC.
Select the "Power Motion i" for Power Motion i-A.
Select the "Series 0i-D" for Series 0i Mate-D.

Add the the following explanation to the following:


- "File list" in the "IV.OPERATION 1.2.2 Display of the Upper Screen (PC Information)"
- "IV.OPERATION 1.5.1 Display of a Data List"

CNC Tool offset Custom macro variable Workpiece origin offset

Power Motion i-A TOOLOFST.TXT MACRO.TXT None

Series 0i Mate-D TOOLOFST.TXT MACRO.TXT EXT_WKZ.TXT

TITLE FANUC PROGRAM TRANSFER TOOL


OPERATOR’S MANUAL
Additional explanation
Power Motion i-A / Series 0i Mate-D support
DRAW. NO. CUST.
01 2011.08.12 Matsukura New Issue T.Hosaka B-64344EN/02-5
SHEET
EDIT. DATE DESIG. DESCRIPTION 4/4