0% found this document useful (0 votes)
23 views

Auto Cad Design

The document provides a drawing list, electrical legend, and cable-conduit schedule for a proposed 6-storied apartment building. It includes labels for various electrical components like meters, distribution boards, switches, lights, fans, and outlets. It also specifies cable types and sizes to be used based on load as well as conduit sizes for routing different cables. Notes provide guidance on socket and outlet placement heights and defining conduit inner dimensions.

Uploaded by

Abdul Alim
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
23 views

Auto Cad Design

The document provides a drawing list, electrical legend, and cable-conduit schedule for a proposed 6-storied apartment building. It includes labels for various electrical components like meters, distribution boards, switches, lights, fans, and outlets. It also specifies cable types and sizes to be used based on load as well as conduit sizes for routing different cables. Notes provide guidance on socket and outlet placement heights and defining conduit inner dimensions.

Uploaded by

Abdul Alim
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

NOTE :

DRAWING LIST ELECTRICAL LEGEND


METER
CHANDELIER / PENDANT LIGHT (CH)
MDB (Main Distribution borad)
SDB (Sub Distribution borad) Earthing

DB (Distribution borad) TV TV 1' Ø PVC CONDUIT for TV Cable


through R.C.C Slab / Wall
SDB gen ( SDB for Afertments Generator
Connected Load) CABLE SCHEDULE
SDB s (SDB for Common Service) C1 = 1- C, 2x1.5 mm2 (BYA) Cable
SB (Switch borad) At 4'-0" FROM F.F. C2 STATUS DATE
= 1- C, 4x1.5 mm2 (BYA) Cable For comments
ESB (Emergency Switch borad) C3 = 1- C, 6x1.5 mm2 (BYA) Cable
C4 For construction
At 4'-0" FROM F.F. = 1- C, 8x1.5 mm2 (BYA) Cable
C5 = 1- C, 10x1.5 mm2 (BYA) Cable
EMERGENCY CEILING FAN (ECF) C6 = 1- C, 2x2.5 mm2 (BYA) Cable +1x1.5 (re) mm2 ECC
C7 = 1- C, 4x2.5 mm2 (BYA) Cable +2x1.5 (re) mm2 E.C.C
CEILING FAN (CF)
C8 = 1- C, 6x2.5 mm2 (BYA) Cable +3x1.5 (re) mm2 E.C.C
WALL FAN (WF) At 7'-6" FROM F.F. C9 = 1- C, 8x2.5 mm2 (BYA) Cable +4x1.5 (re) mm2 E.C.C.
C10 = 1- C, 10X2.5 mm2 (BYA) Cable +5x2.5 (re) mm2 E.C.C
EXHAUST FAN (EX) C11 = 1- C, 2X4.0 mm2 (BYA) Cable +1x2.5 (re) mm2 E.C.C
C12 = 1- C, 4X4.0 mm2 (BYA) Cable +2x2.5 (re) mm2 E.C.C
AC
C13 = 1- C, 6X4.0 mm2 (BYA) Cable +3x2.5 (re) mm2 E.C.C Lecture-03
WALL BRACKET LIGHT (WL) At 7'-6" FROM F.F.
C14 = 1- C, 2X6 mm2 (BYA) Cable +1x4 mm2 E.C.C
EMERGENCY LIGHT (EWL) AT 7'-6' FROM F.F. Fig. 2. 01
FALSE LIGHT (FL) C15 = 4x 1C X 10.0 Sq.mm NYY / BYA +6.0 Sq. mm ECC
C16 = 4x 1C x 16.0 Sq.mm NYY / BYA + 10.0 Sq. mm ECC
EMERGENCY TUBE LIGHT (ETL)
C51 = 1x2 Pair Telephone Cable
TUBE LIGHT (TL) PROJECT: "LUMINIERE"
C52 = 2x2 Pair Telephone Cable
4x20W TUBE LIGHT (TT) PROPOSED 6-STORIED APPARTMENT
C81 = 1x1 No. TV Co-axial Cable
BUILDING FOR ............. AT PLOT# 119,
MIRROR LIGHT (ML)
ROAD # 04, BLOCK # A, BANANI
CEILING LIGHT (CL) DHAKA, BANGLADESH.

CIRCULAR TUBE LIGHT (CTL) CONDUIT SCHEDULE


SURFACE SPOT LIGHT (SP)
Conduit Size Number of Cable Code
CONCEAL SPOT LIGHT (SPC) (Inside dia.) Conduit
CIRCULAR BOX (CB)
5A/10A 3 PIN SOCKET BOX BOTTOM 7/12" (16mm) 1 no. C1,C6, C51,
AT 9" FROM F.F. (P)
3/4" (19mm) 1 no. C2,C3, C52,C61
15A/16A 3 PIN SOCKET (Q) for AC
C71,C81,C91,
5A/10A 2 PIN SOCKET BOX BOTTOM C101,
AT 9" FROM F.F. (R)
1" (25mm) 1 no. C4,C5,C7,C8,
5A/10A 2 PIN SOCKET SWITCH BOARD LEVEL (S) C11,C12,C14,
15A/16A 3 PIN SOCKET (G) for GEYSER
C9,C10, Drawing list, electrical legend
PVC CIRCULAR BOX (CB) 1.25" (30mm) 1 no.
& cable - conduit schedule.
TELEPHONE OUTLET (TEL)
1.5" (38mm) 1 no. C13,C15
INTER COM OUTLET (IC)
CALLING BELL PUSH (BP) 2.0" (50mm) 1 no. C16,C17
CALLING BELL (CB)
3.0"(75mm) 1 no. C18
TV CABLE OUTLET (TV)
Emergency Cabinet / Junction Box (EJB)

Telephone Cabinet / Junction Box (TJB)


IMPORTANT NOTE :
TV Cable Junction Box (TV JB) 01. All Sockets shall be with Switch.
02. All power outlets P, Q etc. shall be at + 10" [250mm] . PEng.
Main Power Cable (Under Ground) from finished floor, unless other wise mentioned. ENGINEERING SERVICE ASSOCIATES
ELECTRICAL SYSTEM DESIGN AND DOCUMENTATION

1' Ø PVC CONDUIT Through R.C.C Slab / Wall. 03. All conduit / pipe dia shown are of inner demensions.
04. All cable shall be of stranded (rm) copper conductor
TEL TEL 1' Ø PVC CONDUIT for Telephone
Cable through R.C.C Slab / Wall