HI 800 069 AEA: Circulating Fan K 9203

The document summarizes a circulating fan drawer with three axial fans used for forced ventilation in 19-inch installations. It provides details on installation location, application, display of operation status and errors using LED lights, material specifications, operating data including voltage, current, air flow rate and lifetime. Monitoring ensures fan speed is within 75-85% of rated speed and triggers a fan fault LED if outside this range.

Uploaded by

Garabig
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
134 views1 page

HI 800 069 AEA: Circulating Fan K 9203

The document summarizes a circulating fan drawer with three axial fans used for forced ventilation in 19-inch installations. It provides details on installation location, application, display of operation status and errors using LED lights, material specifications, operating data including voltage, current, air flow rate and lifetime. Monitoring ensures fan speed is within 75-85% of rated speed and triggers a fan fault LED if outside this range.

Uploaded by

Garabig
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

HI 800 069 AEA

K 9203
Circulating Fan K 9203

Circulating fan drawer with three axial fans,


with fan run monitoring

Installation: At any location in the 19-inches field

Application: Forced ventilation of 19-inches installations


Note: The positions of the axial fans in the K 9203 drawer are adapted to
the subracks of the recessed HIMA subrack systems.

Display of operation and errors:

Operation status Connector pin 4-5 Connector pin 5-6 LED LED
Contact Contact FAIL 24 V
Without fault open closed OFF ON
Operating voltage
missing or closed open OFF OFF
fuse failure
Fan fault * closed open ON ON
* Fan speed < 75...85 % of the rated speed

Material Aluminium, anodized


Operating data 24 V DC / 750 mA
Air flow rate 280 m3 per hour
Life time at 40 °C 70 000 h
Weight 1.8 kg