GD - 40 - Manual Service Control Box
GD - 40 - Manual Service Control Box
Installation:
Mechanical
Mount the GD-40 in a non-dusty area in the cockpit. Mount such that there is a no obstruction to the fan. Possible locations include bulkheads
behind the instrument panel and side panels.
Mount the supplied Bi-Color LED and button next to each other in a visible location on the instrument panel.
Electrical
Configuring your Installation: The GD-40 is capable of producing warnings via LED illumination, Audio warning, EFIS communications and a
discrete relay switch. Any combination of these external connections may be made as desired for your installation. At a minimum the LED and button
should be installed.
V+ (power) 12-28 Volts DC, Connect to the avionics bus via a 1 Amp fuse.
GND (Ground) Two identical grounds are provided. One should be connected to the aircraft ground. The other may be used for the LED connection,
audio shield, button ground and/or Serial data cable shield. It is acceptable to connect more than one wire to a ground terminal.
LED1 (Red LED) Connect to the red wire on the supplied LED
LED2 (Green LED) Connect to green wire on the supplied LED
(connect LED the black wire to ground GND)
AUD (audio out) Connect to an unswitched audio input in on your radio or intercom. Use 22-24AWG shielded wire. Connect one end of the shield to
ground. If your radio or audio panel does not have an unswitched audio input you will need to purchase an audio mixer. We suggest our AP-60 Mixer.
BUT (button) Connect to one terminal of the supplied button. Connect the other button terminal to ground. We suggest using 22-24AWG shielded
wire using the shield as the ground connection.
RLY (Relay) This terminal connects to ground (is pulled low) when a CO alarm is present. Connect this to an EFIS “switch input” or it can complete
the circuit for an external warning lamp. Do not connect this terminal to 12-28 Volts
Setup:
Once you have connected the detector, perform the following tests to verify your installation.
Test 1: PRESS and HOLD the button, RELEASE the button when the LED begins to flash RED and GREEN.
Test 2: PRESS and RELEASE the button to perform the following tests:
Volume Control:
An audio volume control is located next to the terminal strip. Be careful not to force the potentiometer past its limits, it is delicate.
Configure the EFIS Serial port connected to the GD-40 for CO detector data.
Rev 4/26/11
Operation:
Upon power up the unit performs a self test and will play the following audio alert, “Carbon Monoxide Detector Test OK”. The Green LED will flash
then extinguish. After two minutes of stabilization, the Green LED should illuminate steadily.
CO Alerts:
• Low: 50 to 100 PPM - Flashing green LED, Voice Alert: "Caution, Carbon Monoxide", Relay connected to ground
• Medium: 100 to 400 PPM - Steady Red LED, Voice Alert: "Warning, Carbon Monoxide", Relay connected to ground
• High: Greater than 400 PPM - Flashing Red LED, Voice Alert: "Danger, Carbon Monoxide", Relay connected to ground
Alerts for lower concentrations of CO are delayed. As the concentration increases to 400PPM alerts occur more quickly.
To acknowledge an alert PRESS the button. The following acknowledgement steps occur:
NOTE: The Detector will continue to send the CO concentration to the EFIS for pilot monitoring. The alert condition is automatically cleared when
the concentration drops below 50PPM.
Some EFIS manufacturers enable the EFIS to send an acknowledgement command to the Detector by pressing a button on the EFIS. An EFIS
acknowledgement performs the same steps as above.
CO Alert Procedures:
Altitude Alerts:
Maintenance:
The sensor in the GD-40 has an expected service life of 5-7 years. Replacement of the sensor and recalibration of the unit must be performed at
the factory. A date code is printed on the sticker on the outside of the unit. The first number in the code is the year of manufacture of the unit
the second three numbers are the day of the year. Example “1302” translates to the 302 nd day of 2011. Contact us to make arrangements for
sensor replacement and recalibration service.
At power up and periodically during operation, the detector performs a self test to confirm it’s integrity. If a problem is detected, “Carbon
Monoxide Detector Test Fail” will be played via the audio system. There are two failure modes that can occur after power up: 1) The LED will
flash RED and GREEN for a sensor failure or 2) The LED flash RED for an internal memory failure. In the case of an internal memory failure, the
unit will operate normally, but with less accuracy. Contact us to obtain service instructions if a failure occurs.
Specifications:
Input Voltage: 12-28 Volts DC
Dimensions: 4.7” X 3.1” X 1.0”
Weight: 4.1 oz. Need Help?
Altitude Compensated to 25000’ Cabin Altitude
Detects as low as 10 PPM CO Concentration [email protected]
or call (831) 325-3131