OBJECT :-
DESIGN ASSUPTION:-
3
SHREE PADMAWATI POLYMERS
F-271,MANDIA ROAD, RIICO INDUSTRIAL AREA,
PALI- MARWAR (RAJASTHAN-306401)
PH. 9829620316
Continue.. ANNEXTURE –I
(2) R.O. TREATED WATER OUT PER SHIFT = 5000 LITRE / SHIFT.
(PRODUCT / PERMEATE WATER)
(4) WASTE WATER OUT PUT PER SHIFT:- = 5000 LITRE / SHIFT.
( REJECT / CONCENTRATE WATER)
4
(4) ELECTRICITY TYPE. = 415Volt./3Ph./50Hz
Continue.. ANNEXTURE –I
BASIS OF DESIGN:-
The following raw water / feed water sourced from well , analysis assumed as
basis of design for R.O. Plant.
01 PH 6–8
02 TOTAL DISSOLVED SOLIDS / TDS 2000 PPM
03 TOTAL SUSPENDED SOLIDS / TSS 20– 50 PPM
04 TURBIDITY < 1.0 NTU
05 SLIT DENSITY INDEX / SDI (15 min.) < 3-5
06 FREE CHLORINE (Cl2) <0.1 – 0.0 PPM
07 FREE ORGANICS NIL
08 IRON / MAGANANE (Fe+3 / Mn+2) NIL
09 TOTAL HARDNESS as CaCO3 100 PPM
10 TOTAL ALKALINITY as CaCO3 75 PPM
11 P. ALKALINITY as CaCO3 NIL
12 OIL & GREASE NIL
13 CHLORIDE (Cl-) as CaCO3 550 PPM
14 FLUORIDE (F-) as CaCO3 <10 PPM
15 SULPHATE (SO4-) as CaCO3 <150 PPM
16 TOTAL SILICA (SiO2) as CaCO3 <20 PPM
17 SODIUM (Na+) as Na <550 PPM 5
18 CONDUCTIVITY uS / cm
SHREE PADMAWATI POLYMERS
F-271,MANDIA ROAD, RIICO INDUSTRIAL AREA,
PALI- MARWAR (RAJASTHAN-06401)
PH.9829620316
Continue.. ANNEXTURE –I
01 PH 6.5- 7
02 TOTAL DISSOLVED SOLIDS / TDS <50 PPM
03 TOTAL SUSPENDED SOLIDS / TSS < 3 PPM
04 TURBIDITY NIL
05 SLIT DENSITY INDEX / SDI (15 min.)
06 FREE CHLORINE (Cl2) NIL
07 FREE ORGANICS NIL
08 IRON / MAGANANE (Fe+3 / Mn+2) NIL
09 TOTAL HARDNESS as CaCO3 0.0 PPM
10 TOTAL ALKALINITY as CaCO3 1 PPM
11 P. ALKALINITY as CaCO3 NIL
12 OIL & GREASE NIL
13 CHLORIDE (Cl-) as CaCO3 <10 PPM
14 FLUORIDE (F-) as CaCO3 <1 PPM
15 SULPHATE (SO4-) as CaCO3 <10 PPM
16 TOTAL SILICA (SiO2) as CaCO3 <0.0 PPM
17 SODIUM (Na+) as Na <15 PPM
18 CONDUCTIVITY uS / cm
6
SHREE PADMAWATI POLYMERS
F-271,MANDIA ROAD, RIICO INDUSTRIAL AREA,
PALI- MARWAR (RAJASTHAN-306401)
PH. 9829620316
DESIGN TEMPRATURE 25 – 35 C
FEED WATER FLOW RATE (M3/hr) 1.0
PERMEATE WATER FLOW RATE (M3/hr) 0.5
REJECT / CONCENTRATE WATER FLOW RATE 0.5
(M3/hr)
TYPE /ARRAY OF RO PLANT Single Stage
SYSTEM RECOVERY OF 1st Stage 50%
OVER-ALL RECOVERY 50%
WORKING PRESSURE FOR 1st Stage 12 Bar
7
SHREE PADMAWATI POLYMERS
F-271,MANDIA ROAD, RIICO INDUSTRIAL AREA,
PALI- MARWAR (RAJASTHAN-06401)
PH. 9829620316
ANNEXTURE- III
DOSING PUMP
MICRON FILTER
R.O. ASSEMBLY
SYSTEM ACCESSORIES
INSTRUMENTS
CONTROL PANEL
SKID
8
SHREE PADMAWATI POLYMERS
F-271,MANDIA ROAD, RIICO INDUSTRIAL AREA,
PALI- MARWAR (RAJASTHAN-306401)
PH. 9829620316
ANNEXTURE- IV
TECHNICAL SPECIFICATION OF EQUIPMENTS
9
(02) MULTI GRADED MEDIA FILTER (MGF)
(PRESSURE SAND FILTER / DUAL MEDIA FILTER)
(2.2) Specification :-
PRESSURE-VESSEL:
Quantity offered : One No
Type : Down Flow – 14” X 54”/ 2.5” TOP
OPENING WITH FAPT & TRIPOD STAND.
VALVE:
10
MEDIA:
(3.2) Specification :-
PRESSURE-VESSEL:
Quantity offered : One No
Type : Down Flow – 14 X 54 /2.5” TOP
OPENING WITH FAPT & TRIPOD STAND.
VALVE:
11
Make : Inetiative / UKL / PREHAR / PENTAIR
Valve Type : MULTI PORT – SINGLE LEVER VALVE
MOC : NORYL .
SIZE OF MPV : 25NB / 25 MM.
MAX. FLOW RATE : 5000LITRE / HOUR.
WORKING FLOW RATE: 1000 LITRE /HOUR ( 1.0 M3 / HR.)
MAX. WORKING : 6 BAR. ( 6.0 kgf. / cm2 ) = 90 psig.
PRESSURE
WORKING PRESSURE : 2.5 – 3.5 BAR ( 2.5 – 3.5 kgf./ cm2 ) = 37.5 – 52.5 psig.
WORKING FLOW : DOWN FLOW.
MEDIA:
12
(5.1) Purpose:- To Remove the Fine particles up to 05 micron
& thereby reducing the SDI (Silt Density Index)
Load containing in feed water to desire level <3
So TSS Load on Membrane gets reduced.
HOUSING:
CARTRIDGE-FILTER:
13
(6.2) Specification of High Pressure Pump:-
14
(7.2) R.O. PRESSURE TUBE :-
15
(a) Incomer Supply Switch :415 V / RYBN- 3phase / 15 Amp.
Siemens, L&T, ABB etc.
(9) INSTRUMENTATION:-
Quantity : 5 Nos.
16
Back entry – Panel side
Purpose :- To Measure the online Flow of Permeate Water & Reject Water.,
And Control the designed set % Recovery by Flow Meter Reading
Of RO System.
Specification of ROTA-METER
17
Purpose:- To Measure the TDS (Total Dissolved Solid ) in Permeate
Water.
Quantity : 1 Nos
Purpose :-
18
(10) PIPING & FITTING:-
ANNEXTURE- V
Our scope shall cover design, engineering , supply and supervision of erection and
Commissioning for the R.O. plant described in the following annexure. The broad
Scope of supply is as follows:-
19
09 R.O. BLOCK ONE
10 INTERCONNECTING PIPE WORK ONE LOT
11 SENSOR CABLES FROM FIELD TO RO ONE
INSTRUMENT PANEL
12 PERMEATE STORAGE TANK & PUMP BY CLIENT
13 INSTRUMENT TDS/CONDUCTIVITY METERONE
14 ROTO-METER TWO
15 PRESSURE INDICATOR Six
16 PRESSURE SWITCH TWO
17 ELECTRIC CONTROL PANEL ONE
18 U-PVC & SS PIPING,FITTINGS & VALVES ONE LOT
19 MS SKID ONE
Our price for the supply of R.O. system 0.500 M3/ Hr.(500 litre per hour) as specified in our
Technical offer / proposal is Rs. 1,35,400/- (Rupees One lacs Thirty FIVE thousand FOUR
hundred only)
20
RO plant – 1500 LPH : Rs 3,15,800/-
Cost of Sintex type HDPE tant will be Rs 5.50 / per Liter. + 18% gst +
transportation charge.
For 500 lph ro plant – 3 tanks of 1000 liter will require.
For 1000 lph ro plant – 3 tanks of 1500 liter will require.
For 1500 lph ro plant – 3 tanks of 2000 liter will require.
Terms of Payments:-
60% of the total value of the order to be paid as advance along with purchase order.
21
Validity:-
Our offer is valid for your consideration for a period of 30 days from the date of our
Proposal./ Offer for RO Plant
Delivery:-
We shall design , manufacture, and supply the equipment within five to Six Weeks
from the Date of receipt of technically and commercially clear order along with advance.
Our RO Plant will carry the Warrantee for One Year from the Date of Invoice against
Any manufacturing defects & Design. Any Faults or / and Breakage occur due to
Mis-operation / faulty running of RO Plant / any kind of working default will not cover
Under the warrantee period.
To,
DATE:-26.11.22
M/s POINEER LIME & MINERALS
FALNA
PALI – RAJ.
Kind Attend. To :-
22
Thank you very much for the courtesy extended to us during our discussion with you . As
per discussion with you & getting inquiry about the feed water characteristics, We
are pleased to give our techno - commercial offer your requirement of Reverse
Osmosis Water Treatment Plant of 500 L.P.H Product / Permeate Water Capacity.
That plant will need about 1000 liter/hr. as feed raw water.
Warm regards.
Rajesh Kothari.
Shree Padmawati Polymers