0% found this document useful (0 votes)
200 views

Installation Information Series PAVC 33/38/65/100: Variable Displacement Piston Pumps

This document provides installation information for variable displacement piston pumps in the Parker PAVC series. It includes an illustration of the generic pump assembly with labeled parts, torque specifications for assembly, and diagrams specifying the control options and part numbers used for different control port configurations.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
200 views

Installation Information Series PAVC 33/38/65/100: Variable Displacement Piston Pumps

This document provides installation information for variable displacement piston pumps in the Parker PAVC series. It includes an illustration of the generic pump assembly with labeled parts, torque specifications for assembly, and diagrams specifying the control options and part numbers used for different control port configurations.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 9

Catalog HY13-1553-002/US Variable Displacement Piston Pumps

Installation Information Series PAVC 33/38/65/100

Generic Pump Assembly

MAX VOL. STOP


VARIATION - 5

95 N·m
(70 FT. LBS.)
TORQUE

MAX VOL. STOP


VARIATION - 2

23 N·m
(17 FT. LBS.)
TORQUE

1 TRUNNION CAP ASSEMBLY 4 RETAINER DETAIL 7 AIR BLEED ASSEMBLY

THRUST WASHER
(Not on PAVC100)

SNAP RING BODY


O-RING SPRING STAKE BALL
TRUNNION CAP IN PLACE
BALL
ROLLER BEARING
5 BEARING SHAFT ASSEMBLY 8 ADJUSTING STEM ASSEMBLY
2 SLEEVE ASSEMBLY

PLUG 1 2 1 1 2
STEM
SLEEVE 1 2 1 2 2 1 O-RING 1
O-RING 1 BACK-UP RING 2
BACK-UP RING 2
9 PORT PLATE
3 PLUG ASSEMBLY 6 PISTON - DIFFERENTIAL LEFT HAND (CCW) PORT PLATE
SHOWN IN ASSEMBLY (ABOVE).
CONTROL
RIGHT HAND (CW) PORT PLATE
SHOWN BELOW.
PISTON BODY
SLEEVE
1 2
O-RING 1
O-RING 1 1 2
BACK-UP RING 2
BACK-UP RING 2

Parker Hannifin Corporation


A100 Hydraulic Pump/Motor Division
Greeneville, Tennessee USA
Catalog HY13-1553-002/US Variable Displacement Piston Pumps
Installation Information Series PAVC 33/38/65/100

THESE ITEMS ARE SHOWN IN


POSITION FOR CONTROL OPTION
“OMIT”. SEE SEPARATE DIAGRAM

13.5 N·m
(10 FT. LBS.)
FOR OTHER CONTROL OPTIONS.
A
TORQUE
169 N·m 5
(125 FT. LBS.)
TORQUE
76

7
108 N·m
(80 FT. LBS.)
TORQUE 6 ADJUSTABLE
2 DIFFERENTIAL
VARIATION - 4

5
9

68 N·m
(50 FT. LBS.)
TORQUE
3
NON-ADJUSTABLE
8 DIFFERENTIAL
VARIATION - OMIT
27 N·m
(20 FT. LBS.)
TORQUE
PAVC 33, 38, 65
Position
Control
1 2 3 4 5
Option
3
Omit Open 800599 108 x 4 108 x 4 Omit
A 102 x 1 800599 Open 108 x 4 787474*
C 102 x 1 800599 Open 108 x 4 787474*
H Open 800599 108 x 4 108 x 4 Omit 10
M 800599 Open Open 108 x 4 Omit
ME 102 x 1 800599 Open 108 x 4 787474*
S 800599 Open Open 108 x 4 Omit 11
SE 102 x 1 800599 Open 108 x 4 Omit 11
AM 102 x 1 800599 786635 Open 787474*
CM 102 x 1 800599 786635 Open 787474* 10
HM 800599 Open Open 108 x 4 Omit 10
4 * Available Only on PAVC65.

PAVC100
POSITION 1 Position
Control ‡
POSITION 2 1 2 3 4 5
Option
Omit Open 690870 108 x 4 108 x 4 787474
10 TORQUE (HP) CONTROL (See next page) A 102 x 1 690870 Open 108 x 4 787474
C 102 x 1 690870 Open 108 x 4 787474
11 VOLUME SERVO FEEDBACK (See next page) H Open 690870 108 x 4 108 x 4 787474 10
M 690870 Open Open 108 x 4 787474
Part Number Description ME 102 x 1 690870 Open 108 x 4 787474
102 x 1 Solid Pipe Plug (1/16") S 690870 Open Open 108 x 4 787474 11
108 x 4 SAE Plug - 4 SE 102 x 1 690870 Open 108 x 4 787474 11
690870 .028 Orifice Plug (1/16") AM 102 x 1 690870 786635 Open 787474
800599 .034 Orifice Plug (1/16") CM 102 x 1 690870 786635 Open 787474 10
786635 .034 Orifice Fitting HM 690870 Open Open 108 x 4 787474 10
787474 Upstroke Spring ‡
787474 is always included with the PAVC100.

Parker Hannifin Corporation


A101 Hydraulic Pump/Motor Division
Greeneville, Tennessee USA
Catalog HY13-1553-002/US Variable Displacement Piston Pumps
Installation Information Series PAVC 33/38/65/100

10 CONTROL OPTION “C” & “H”


PRESSURE, POWER & FLOW

27 N·m (20 FT.-LBS.) TORQUE


14 N·m (10 FT.-LBS.) TORQUE
10-32UNF-2B SET @ MAX. PRESSURE PER TEST
OMIT SPEC. THEN INSTALL JAM NUT, LOCKING
NUT AND LOCKING TAB.

ADD

11 CONTROL OPTION “S” & “SE”


SERVO VOLUME FEEDBACK

16 N·m (12 FT.-LBS.) TORQUE

HAND TIGHTEN NUT


TORQUE AT TEST

102 x 1 PIPE
PLUG

ADD
98 x 16 BALL
ADD

10-32UNF-2B OMIT
NOTE: Install ball through torque port, seat in place through bolt hole.

SERVO VOLUME ASSEMBLY


PIPE PLUG
102 x 1

RETAINING O-RING
SLEEVE
O-RING PROBE
SPRING

BALL
LVDT ASSEMBLY
PUMP SERVO
HOUSING VOLUME LOCKING NUT
CONTROL HOUSING
BUTTON
SERVO
PISTON

Parker Hannifin Corporation


A102 Hydraulic Pump/Motor Division
Greeneville, Tennessee USA
Catalog HY13-1553-002/US Variable Displacement Piston Pumps
Installation Information Series PAVC 33/38/65/100

Additional PAVC Options

Consult factory for more information.

Parker Hannifin Corporation


A103 Hydraulic Pump/Motor Division
Greeneville, Tennessee USA
Catalog HY13-1553-002/US Variable Displacement Piston Pumps
Technical Information Series PAVC

Non-Standard Shaft and Pilot Options - PAVC65

41.14 45.97
(1.62) (1.81)
9.39 9.39
SAE “B” (.370) SAE “BB” (.370)
SPLINED SHAFT SPLINED SHAFT
13 TOOTH 15 TOOTH
16/32 PITCH 16/32 PITCH

B B
101.60 (4.000) 101.60 (4.000)
Ø 101.54 (3.998) Ø 101.54 (3.998)
SAE “B” PILOT SAE “B” PILOT

SAE “B” PILOT SAE “B” PILOT


SAE “B” SPLINE SHAFT SAE “BB” SPLINE SHAFT
(SINGLE PIECE SHAFT) (SINGLE PIECE SHAFT)

55.62 41.14
(2.19) (1.62)
9.39 12.44
SAE “C” (.370) SAE “B” (.490)
SPLINED SHAFT SPLINED SHAFT
14 TOOTH 13 TOOTH
12/24 PITCH 16/32 PITCH

B B
101.60 (4.000) 127.00 (5.000)
Ø 101.54 (3.998) Ø 126.94 (4.998)
SAE “B” PILOT SAE “C” PILOT

9.65 (.380) WIDE FLAT

SAE “B” PILOT SAE “C” PILOT


SAE “C” SPLINE SHAFT SAE “B” SPLINE SHAFT
(DUAL BEARING SHAFT) (SINGLE PIECE SHAFT)

Non-Standard Shaft and Pilot Option - PAVC100


74.67
(2.94)
12.44
(.490)
SAE “D”
SPLINED SHAFT
13 TOOTH
8/16 PITCH

B
SAE “C” PILOT
SAE “D” SPLINE SHAFT 127.00 (5.000)
Ø 126.94 (4.998)
(SINGLE PIECE SHAFT)
OR SAE “C” PILOT
(DUAL BEARING SHAFT)

Parker Hannifin Corporation


A104 Hydraulic Pump/Motor Division
Greeneville, Tennessee USA
Catalog HY13-1553-002/US Variable Displacement Piston Pumps
Technical Information Series PAVC

Harsh Environment Seal Option


BEARING BEARING
GLAND GLAND
PAVC65 PAVC100
DETAIL DETAIL
BEARING BEARING
A

SHAFT SEAL SHAFT SEAL


W/ WIPER W/ WIPER

SNAP RING O-RING SNAP RING O-RING

SNAP RING SPECIAL TWO PIECE SHAFT SNAP RING SPECIAL TWO PIECE SHAFT
(SPIRAL) DUAL BEARING DESIGN (SPIRAL) DUAL BEARING DESIGN

PAVC65 - Harsh Environment-Shaft and Pilot Configurations


48.00 61.46 55.62
(1.89) (2.42) (2.19)
7.62 (.30) 9.39 12.44 12.44
9.65 (.380)
WIDE FLAT (.370) (.490) (.490)
WIDE FLAT

31.75 (1.250)
B Ø 31.69 (1.248) B B
101.60 (4.000) 127.00 (5.000)
Ø 101.54 (3.998) 127.00 (5.000) Ø 126.94 (4.998)
Ø 126.94 (4.998)
SAE “B” PILOT SAE “C” PILOT
SAE “C” PILOT

9.65 (.380)
WIDE FLAT
SAE “B” PILOT SAE “C” PILOT SAE “C” PILOT
SAE “B” SPLINE SHAFT 1-1/4" (31.75) DIA. SAE “C” SPLINE SHAFT
13 TOOTH, 16/32 D.P. 5/16" (7.9) KEYED SHAFT 14 TOOTH, 12/24 D.P.

PAVC100 - Harsh Environment-Shaft and Pilot Configurations


57.65 55.62
(2.27) (2.19)
12.44 12.44
(.490) (.490)
7.92 (.312)
WOODRUFF KEY 9.65 (.38)
WIDE FLAT

B B
31.75 (1.250)
Ø 31.69 (1.248)
127.00 (5.000)
127.00 (5.000) Ø 126.94 (4.998)
Ø 126.94 (4.998)
SAE “C” PILOT
SAE “C” PILOT

9.65 (.38)
WIDE FLAT

SAE “C” PILOT SAE “C” PILOT


1-1/4" (31.75) DIA. SAE “C” SPLINE SHAFT
5/16" (7.9) KEYED SHAFT 14 TOOTH, 12/24 D.P.

Parker Hannifin Corporation


A105 Hydraulic Pump/Motor Division
Greeneville, Tennessee USA
Catalog HY13-1553-002/US Variable Displacement Piston Pumps
Technical Information Series PAVC

Sculptured Housings - PAVC65


NOTE:
There are many sculptured housings and special porting configurations
for applications where the standard PAVC has interference. Consult factory. 87.37 87.37
(3.44) (3.44)

52.0 52.07
(2.05) (2.05)
GAGE PORT 26.92 GAGE PORT 26.92
7/16-20 UN-2B (1.06) 7/16-20 UN-2B (1.06)
ST.THREAD ST.THREAD
O-RING SAE-4 O-RING SAE-4
74.93 R 74.93 R
(2.95) (2.95)

64.26 64.26
(2.53) (2.53)
27.17 27.17
(1.07) (1.07)

OUTLET PORT OUTLET PORT


7/8-14 UN-2B 7/8-14 UN-2B
ST.THREAD ST.THREAD
O-RING SAE-10 O-RING SAE-10

Special (Dual) Inlet - PAVC65 NOTE:


INLET PORT
Top Port: 1-1/2" SAE Flange Dual inlet recommended in applications where 1-7/8-12 UN-2B
Rear Port: SAE-24 O-Ring pump operating speed exceeds 2700 RPM ST.THREAD O-RING
without inlet precharge pressure. SAE-24
192.02 38.10
(7.56) (1.50)

1/2-13 UNC-2B
4 PLACES
Ø 35.10 (1.50)

69.85
(2.75)

INLET PORT
1-1/2" SAE
4-BOLT FLANGE

35.81 85.85
(1.41) (3.38)

Special (Top) Inlet - PAVC65


Top Port: SAE-24 O-Ring
192.02 86.10
(7.56) (3.39)
INLET PORT
1-7/8-12 UN-2B
ST.THREAD O-RING
SAE-24

Parker Hannifin Corporation


A106 Hydraulic Pump/Motor Division
Greeneville, Tennessee USA
Catalog HY13-1553-002/US Variable Displacement Piston Pumps
Technical Information Series PAVC

Transmission Spacer NOTE: Spacer mounts on pilot of pump in order to move


1/2-13 X 3-1/4" LG
SAE “B” Pilot the pump away from transmission when there is
38.10 an interference problem. Consult factory. HEX HEAD BOLT
(1.50) RECOMMENDED
13.46 1/2" HEAVEY DUTY
(.53) WASHER RECOMMENDED

A
73.02 SPACER / PUMP
(2.875) B
ASSEMBLY
Ø101.600 (4.000) Ø101.625 (4.001)
101.549 (3.998) 101.676 (4.003)

Ø 88.90
(3.50)
73.02 SPECIAL
(2.875) EXTENDED
SHAFT
GASKET

SPACER
9.39 Ø 14.27 (0.562)
(.370) 2 PLACES O-RING

Speed Pickup NOTE: The speed pick-up option is a provision for a


speed sensor to read off the flutes on the barrel.
PAVC 33, 38, 65 Consult factory. MAX GAP = .162
NOTE: PAVC65 Shown
MIN GAP = .078

SENSOR ADAPTER
(303 STAINLESS STEEL)
PRESS FIT INTO HOUSING
BARREL FLUTES
(7 ON PAVC65)
(5 ON PAVC33/38)

PISTONS
(7 ON PAVC65)
(5 ON PAVC33/38)
CUSTOMER
SUPPLIED
SPEED SENSOR
(5/8-18 UNF REF.)

PUMP
HOUSING

Pump Enable NOTE: The pump enable option allows the pump
to go lower than catalog low-press.
PAVC33/38 SPECIAL
EXTERNAL MODIFIED
standby setting. consult factory HOUSING
CONTROL ONLY
PAVC65
AVAILABLE WITH ENABLE
SOLENOID BOLTED
CONTROL
TO PUMP DRAIN REF.
A

ENABLE PORT
7/16-20 UNF-2B
CUST. SUPPLIED ST.THR’D O-RING

177.80 A PAVC100 STANDARD


(7.00) EXTERNAL HOUSING
APPROX. 134.36
(5.29) CONTROL ONLY

CONTROL
23.36 DRAIN REF.
(.92)

A
35˚
PORT “A”
CONTROL DRAIN 31.49
43.18 (1.24) ENABLE PORT
(1.70) 9/16-18 UNF-2B
7/16-20 UNF-2B
APPROX. ST.THR’D O-RING
CUST. SUPPLIED ST.THR’D O-RING

Parker Hannifin Corporation


A107 Hydraulic Pump/Motor Division
Greeneville, Tennessee USA
Catalog HY13-1553-002/US Variable Displacement Piston Pumps
Installation Information Series PAVC 33/38/65/100

Use Of A Relief Valve


The use of a relief valve, while not mandatory is
recommended in the main circuit to suppress hydraulic
shock loads and additional system protection. If a
minimum volume stop is used,
the use of a relief valve is mandatory.

Fluid Recommendations
Premium quality hydraulic oil with a viscosity range
between 150-250 SSU (30-50 cst.) at 38°C (100°F).
Normal operating viscosity range between 80-1000
SSU (17-180 cst.). Maximum start-up viscosity is
4000 SSU (1000 cst.).
NOTE: Consult Parker when exceeding 71°C (160°F)
operation. Oil should have maximum anti-wear
properties, rust and oxidation treatment.

Filtration Installation and Mounting


For maximum pump and system component life, When a PAVC Series Pump is mounted above the fluid
the system should be protected from contamination at level, the position of the “control drain” is not restricted
a level not to exceed 125 particles greater than but the inlet port should not be on the bottom
10 microns per milliliter of fluid. (SAE Class 4/ISO (PAVC100). When a PAVC Series Pump is mounted
16/13). Due to the nature of variable displacement below the fluid level the position of all ports are not
pumps, variations in pump inlet conditions, fluid restricted. The “control drain” should be a separate line
acceleration losses, system aeration, and duty cycle to the reservoir and extend below the oil level as far
we do not recommend suction line filters. We do from the inlet line as possible. The “control drain” line
recommend the use of a properly sized, in-tank suction can be filtered and/or cooled (must not exceed 7 bar
strainer. Contact your Parker representative for (100 PSI) back pressure). Suggested maximum line
assistance. length is 10 feet.
Start-Up A built in airbleed is standard on all PAVC 33, 38, 65
On initial start-up, the case should be filled with oil, and 100 Pumps. To connect, remove airbleed drain
pressure should be reduced and the circuit should be plug and connect a line unrestricted to reservoir
open or the air bled from the pump outlet to permit extending below minimum oil level. Back pressure
priming. Use of the airbleed is recommended on initial in this line must not exceed .28 bar (4 PSI).
start-up. See Installation and Mounting Section to
connect airbleed. Special Installations
Consult your Parker representative for any application
Inlet Conditions requiring the following:
Not to exceed .17 bar (5 In. Hg.). Vacuum at 1800 RPM
Pressure above rated, drive speed above maximum,
on petroleum base fluids. See recommended speed
indirect drive, fluid other than petroleum oil,
spectrum for specific inlet conditions.
oil temperature above 71°C (160°F).
Shaft Rotation and Line Up Inlet Pressure
Pump and motor shaft alignment must be within
Not to exceed 1.72 bar (25 PSI).
.010 TIR maximum, using a standard floating coupling.
Please follow coupling manufacturer’s recommended
installation instructions to prevent
end thrust on pump shaft. Turn pump to assure
freedom of rotation. Pump and motor must be
on a rigid base.
The coupling should be sized to absorb the peak
horsepower developed.

Parker Hannifin Corporation


A108 Hydraulic Pump/Motor Division
Greeneville, Tennessee USA

You might also like