0% found this document useful (0 votes)
175 views14 pages

Brosur, Manual Dan DoC Light Meter DT-8808

The document compares and contrasts the features of various light meters made by CEM. The DT-1300/1301/1308/1309 pocket-sized light meters measure light levels in lux or foot-candles over a wide range, with an easy-to-use function switch and accurate LCD display. They have an over-range indication, long-life silicon photo diode, and measurement rate of 1.5 times per second. The DT-8808/8809A professional light meters have an LCD display with 4000 counts, auto-ranging, analog bargraph, peak hold, relative mode, data hold, auto power off, low battery indication, and user-selectable lux/foot-candle scales.

Uploaded by

yashiro732
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
175 views14 pages

Brosur, Manual Dan DoC Light Meter DT-8808

The document compares and contrasts the features of various light meters made by CEM. The DT-1300/1301/1308/1309 pocket-sized light meters measure light levels in lux or foot-candles over a wide range, with an easy-to-use function switch and accurate LCD display. They have an over-range indication, long-life silicon photo diode, and measurement rate of 1.5 times per second. The DT-8808/8809A professional light meters have an LCD display with 4000 counts, auto-ranging, analog bargraph, peak hold, relative mode, data hold, auto power off, low battery indication, and user-selectable lux/foot-candle scales.

Uploaded by

yashiro732
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 14

CEM DT-8808/8809A DT-1300/1301/1308/1309 CEM

Professional Light Meters Light Meters

LUX 1300/1301/1308 are easy to use with pocket size and light weight, providing
FC PC-Link accurate display light level in terms of Foot Candles (FC) or LUX over wide range. LUX
Light (LUX/FC) Backlight PC interface Just turning the Function Switch to select the “lux” scale and setting the range to FC PC-Link
desired range, then removing the photo detector to light source in a horizontal posi- Light (LUX/FC) Backlight PC interface

tion and reading the illuminance norminal from the LCD display. When the mea-
surement is completed, replace the photo detector from the light source.

Over-range indication Widest range to 40,000Fc/


Long life silicon photo diode inside 400,000 Lux
Measurement rate:1.5 times per second

Features
1300 1301 1308/1309
LCD display counts 2000 2000 4000
Auto Ranging *
Analog bargraph/segments 41-segments
Peak Hold * * *
Relative mode *
Max and Data Hold * *
Auto Power Off * *
Low battery indication * * *
User selectable FC/Lux * *
USB interface -/*
Model 1308
Total accuracy: for C.I.E standard illuminate A(2856K)

Over-range indication Specifications


Long life silicon photo diode inside Max Range 50,000lux/Fc(1300,1301); 400,000Lux(1308)
Measurement rate:1.5 times per second
Accuracy ±5%±10d(<10,000Lux)
Widest rang to 40,000FC/400,000lux
±10%±10d(>10,000Lux)

Features Max Resolution 0.1lux/Fc


8808 8809A Measuring rate 1.5 times/second
EMC
LCD display counts 4000 4000 Photo Detector 115mm x 60mm x 27mm
EN: 61326
Auto Ranging * *
Analog bargraph/segments 41-segments 41-segments
Model 1301
Peak Hold * *
Relative mode * *
Max and Data Hold * *
Auto Power Off * *
Low battery indication * * DT-1307 Solar Power Meter
User selectable FC/Lux * *
Features
Output USB Sunlight measurement up to 1999w/m2 or 634BTU/(ft2*h)
Capacity for data logging 99 * High accuracy and rapid response
Data Hold funtction to hold measurement values
Total accuracy: for C.I.E standard illuminate A(2856K)
Unit and sign display for easy reading
Measuring unit selection among w/m2 and BTU/(ft2*h)
Specifications Manual scale selection
8808 8809A
Widest range to 40,000Fc/ 400,000 Lux Direct reading with no adjustments needed
Max Range 400,000Lux 400,000Lux
Maximum and minimum values
±5%±10d(<10,000Lux) ±3% rdg ±5% f.s.(<10,000Lux)
Accuracy 8808/8809A light meters provide accurate Low battery indication
±10%±10d(>10,000Lux) ±4%rdg ±10d(>10,000Lux)
display light level in terms of Foot Candles (FC)
Max Resolution 0.1Lux/0.01Fc
Measuring rate 1.5 times/second or LUX over wide range. Just turning the Func- Specifications
Photo Detector 115mm x 60mm x 27mm tion Switch to select the “lux” scale and setting the Display 3-1/2 digits LCD with maxmum reading 1999.
range to desired range, then removing the photo Range 1999W/m2,634BTU/(ft2*h)
Size(HxWxD): 203mm x 75mm x 50mm detector to light source in a horizontal position and Resolution 1W/m2;1BTU/(ft2*h).
Weight: 280g Accessories : Accuracy typically within ±10W/m2 [±3BTU/(ft2*h)]or ±5%
reading the illuminance norminal from the LCD
Accessories : One 12V (A23) battery and One Photo Detector.(1300,1301) Sampling time Approx 0.25 second.
display. When the measurement is completed, re-
9V battery, Photo Detector and USB cable(8809A), One 9V battery and One Photo Detector.(1307/1308/1309) Size(HxWxD): 162mm x 63mm x 28mm
place the photo detector from the light source.
software(8809A), Carrying case and Gift box. Carrying case and Gift box. Weight: 176g
USB Interface

273 www.cem-i nstr uments.com


E-mail:cemyjm@cem-i nstr uments.com
w w w.c em-i ns tr uments.c om
E-mail:cemyjm@c em-i ns tr uments.c om
274
Operating Instruction for
Data Logger Light Meter

Please read this manual before switching the unit on.


Important safety information inside.
Data Logger Light Meter

Content Page
1.Instruction....................................................................................4
2.Features....................................................................................... 4
3.Specifications...............................................................................5
4.Description................................................................................... 6
5.Operating Instructions.................................................................. 7
6.Battery Check-Up & Replacement................................................. 9
7.Spectral Sensitivity Characteristic................................................. 9
8.Connecting to PC.......................................................................... 9
9.Installing the Software..................................................................9
10.Maintenance...............................................................................10
11.Recommended Illumination.........................................................10

3
Data Logger Light Meter

1.Instruction
• The digital illuminance meter is a precision instrument used to measure illuminance (Lux, footcandle) in the field.
• It is meet CIE photopic spectral response.
• It is fully cosine corrected for the angular incidence of light.
• The illuminance meter is compact, tough and easy to handle owing to its construction.
• The light sensitive component used in the meter is a very stable, long-life silicon photo diode and spectral
response filter.

2.Features
• Light-measuring levels ranging form 0.1Lux~0.1kLux/0.01FC~0.01kFC, repeatedly.
• High accuracy and rapid response.
• Data-hold function for holding measuring values.
• Unit and sign display for easy reading.
• Automatic zeroing.
• Meter corrected for spectral relative efficiency.
• Correction factor need not be manually calculated for non-standard light sources.
• Short rise and fall times.
• Peak-hold function for tracing the peak signal of light pulse with least duration 10µs and keep it.
• Capable of selecting measuring mode in Lux or FC scale alternatively.
• Auto power off 15minutes or disable Auto Power Off.
• Maximum and minimum measurements.
• Relative reading .
• Easy to read large backlit display.
• USB output connect with PC.
• 4 Level ranging.
• 99 values in memory ,that could be read on the meter.
• More than 16000 values records datalogger.

4
Data Logger Light Meter

3.Specifications
Display 3-3/4 digit LCD with high speed 40 segment bar graph.
Measuring Range 400.0Lux, 4000Lux, 40.00kLux and 400.0kLux / 40.00FC, 400.0FC, 4000FC, 40.00kFC
Note: 1FC=10.76Lux, 1kLux=1000Lux, 1kFC=1000FC
Over Range Display LCD will show “OL” symbol.
Spectral Response CIE Photopic (CIE human eye response curve).
Spectral Accuracy CIE V λ function f1’<6%
Cosine Response f2’ <2%
Accuracy ±3% rdg±0.5%f.s. (<10,000Lux); ±4% rdg±10d. (>10,000Lux)
Repeatability ±3%
Sampling Rate 1.3 times/sec of analog bar-graph indication; 1.3times/sec of digital display.
Datalogger sampling could be setup.
Photo Detector One silicon photo diode and spectral response filter.
Operating Temperature 0 to 40°C (32 to 104°F)
Operating Humidity 0% to 80%RH
Storage Temperature -10 to 50°C (14 to 140°F)
Storage Humidity 0% to 70% RH
Power Source 1 piece 9V battery
Photo Detector Lead Length 150cm (approx.)
Photo Detector Dimensions 115 x 60 x 20mm (L x W x H)
Meter Dimensions 170 x 80 x 40mm (L x W x H)
Weight 390g
Accessories Carry Case, Instruction Manual, Battery

5
Data Logger Light Meter

4.Description
1-LCD Display
2-USB Interface
3-UNITS Button
4-Backlight/LOAD Control Button
5-RANGE Button
6-REC/SET Button
7-MAX/MIN Button
8-Peak Hold Button
9-REL Button 12
10-Data Hold Button
11-Power Button 1
12-Photo Detector
13-Battery Cover 2

4
3 5
6
7

8 9

10 11

13

6
Data Logger Light Meter

5.Operating Instructions
5-1.Power-Up
Press the Power Button to turn the meter ON or OFF.

5-2.Selecting the Lux or FC scale


Set the RANGE Button to desired Lux or FC range.

5-3.Auto Power Off


Press the REC/SET Button and RANGE/APO Button, enable the Auto Power Off or disable this function.

5-4.Over Range
• If the instrument only displays “OL”, the input signal is too strong, and a higher range should be selected.
• The range will show on the down of the LCD.
• LUX: 400->4k->40k->400k; FC: 40-> 400->4k->40k.

5-4.Data-Hold Mode
• Press the Data Hold Button to select Data-Hold mode.
• When Data-Hold mode is selected, the illuminance meter stops all further measurements.
• Press the Data Hold Button again to exit Data-Hold mode, then it resumes normal operation.

5-5.Peak-Hold Mode
• Press the Peak Hold Button to choose Pmax or Pmin recorder mode, and expose the photo detector to light
pulse measuring field.
• Press the Peak Hold Button again to exit PEAK recorder mode, then the meter will resume normal operation.

5-6.Maximum and Minimum Mode


• Press the MAX/MIN Button to choose the Maximum (MAX) reading, Minimum (MIN) reading and current reading
(MAX/MIN blink) recorder mode.
• Press the MAX/MIN Button again to exit this mode.

5-7.Relative Reading Mode


• Press the REL Button to enter Relative mode.
• The display shown zero value and the current reading will be stored as a zero-in value.
• Press the REL Button again to exit this mode.

5-8.USB Mode
Connect with PC with USB, the “ ” will displays in the screen.

5-9.Back-Light Function
Press the Backlight Button to turn on; Press again to turn off.

7
Data Logger Light Meter

5-10.Setup Time and Sampling Rate


• Press the MEM/SETUP Button and UNITS Button key start to setup the time and sampling.
• The first setup target is the hour, press the PEAK or REL Button to choose the object of the setting
• Press the REL Button to choose object to repeat as below process: Hour->minter->second->sampling->month->
day->week->year->hour……
• Press the PEAK Button to choose the object and repeat as below process: Hour->year->week->day->month->
sampling->second->minter->hour->year……
• Press the MAX/MIN Button to add object of setting, press the HOLD Button to reduce the object of seting.
• Hold the MEM/SETUP and UNITS Button to exit the setting time and sampling mode, and then confirm.

5-11.MEM Function
• Press the MEM/SET Button to save the present data.
• HOLD the LOAD Button 5s start to load the records.
• Press the MAX/MIN Button to add the number of records.
• Press the HOLD Button to reduce the number of records.
• After you do that you must hold the LOAD Button 5s to resume normal operation.

5-12.Datalogger Function
• Setup the time and sampling rate first, the default sampling rate is 1s.
• Hold the MEM/SETUP Button 5s, start the datalogger function, the MEM on the screen will be bicker.
• If the memory IC is full ,the memory number will show ‘OL’.
• Press the MEM/SETUP Button 5s, stop the datalogger function, then the meter will resume normal operation.
• Then the datalogger number will return to 1, you could start your records again.
• HOLD the MEM/SETUP and LOAD Button 5s to clear the 99 memory.

8
Data Logger Light Meter

6.Battery Check-Up & Replacement


1.As the battery power is not sufficient, LCD will display low battery and replacement of one new battery is required.
2.After turning off the meter, disconnect the battery cover with a screwier.
3.Disconnect the battery from the instrument and replace it with a standard 9V battery and go for the cover.

7.Spectral Sensitivity Characteristic


To the detector, the applied photo diode with filters makes the spectral sensitivity characteristic almost meet
C.I.E.(INTERNATIONAL COMMISSION ON ILLUMINATION) Photo curve V ( λ) as the following chart described.

8.Connecting to PC
8-1.System requirements
Windows 98 or windows 2000 (or higher).

8-2.Minimum hardware requirements


PC or notebook, 90MHz Pentium of faster, 32Mb Ram, at least 5Mb free hard disk space screen resolution 800x600.

8-3.Connection
1.Switch the light meter on.
2.Plug the other end of the connecting cable to serial interface of the PC (USB).
3.Plug the USB line connecting cable 13.6mm jack plug into the meter socket
4.Start the light meter software.
5.Selecting the COM port 3, note select the 4 COM.
Note: You should better switch the light meter on before you plug the USB line connecting cable 13.6mm jack plug
into the meter.

9.Installing the Software


1.Stare windows
2.Close any applications possibly open before installing the “CEM.LINK” software.
3.nsert the CD into the CD-drive.
4.Enter x:\setup in the command line and press OK, the files setup.exe and the help file will be copied onto the
hard disk (selected path: c:\program files\ Lightmeter), x is the drive-letter of your CD-drive ,e.g. ”g”.
5.Now follow the installation program instructions.
9
6.Once the software is installed, switch on the meter.
7.Start the software.
8.Selected the COM port 3, note is 4.
9.If the connection is in order, the following display will be seen on the screen; If the connection is not in order,
the message “NO CONNECTION” appears on the screen.

10.Maintenance
• The white plastic disc on the top of the detector should be cleaned with a damp cloth when necessary.
• Do not store the instrument where temperature or humidity is excessively high.
• The reference level, as marker on the face plate, is the tip of the photo detector globe.
• The calibration interval for the photo detector will vary according to operational conditions, but generally the
sensitivity decreases in direct proportion to the product of luminous intensity by the operational time.
• In order to maintain the basic accuracy of the instrument, periodic calibration is recommended.

11.Recommended Illumination
Locations Lux FC
Office Conference, Reception Room 200~750 18~70
Clerical Work 700~1,500 65~140
Typing Drafting 1,000~2,000 93~186
Factory Visual Work At Production Line 300~750 28~70
Inspection Work 750~1,500 70~140
Electronic Parts Assembly Line 1,500~3,000 140~279
Packing Work, Entrance Passage 150~300 14~28
Hotel Public Room, Cloakroom 100~200 9~18
Reception 200~500 18~47
Cashier 750~1,000 70~93
Store Indoors Stairs Corridor 150~200 14~18
Show Window, Packing Table 750~1,500 70~140
Forefront of Show Window 1,500~3,000 140~279
Hospital Sickroom, Warehouse 100~200 9~18
Medical Examination Room 300~750 28~70
Operating Room, Emergency Treatment 750~1,500 70~140
School Auditorium, Indoor Gymnasium 100~300 9~28
Class Room 200~750 18~70
Laboratory, Library, Drafting, Room 500~1,500 47~140
1FC=10.76Lux

10
Data Logger Light Meter

Rev.210719
EMC Declaration of Conformity(DoC)

No: WT168003337

Applicant: SHENZHEN EVERBEST MACHINERY INDUSTRY CO.,LTD

Address: 19th Building, 5th Region, Baiwangxin Industrial Park,Songbai


Rd.,Baimang,Xili, Nanshan, Shenzhen,China

has successfully demonstrated that its product


Product: Professional Environment Meter

Model:: DT-8890, DT-8880, DT-8808, DT-8809, DT-8809A, DT-8890A,DT-8890B,


DT-8890C, DT-8891, DT-8891A, DT-8891B,DT-8891C, DT-8891D, DT-8891E,
DT-8892, DT-8893,DT-8894, DT-8896, DT-8897, DT-8920, DT-8920B,DT-8921,
DT-618, DT-618B, DT-619, DT-620

Brand: CEM

are compliant with

EMC: EN 61326-1:2013 IEC 61326-1:2012


EN 61326-2-1:2013 IEC 61326-2-1:2012

This certificate of compliance shows that the tested sample technically complies with essential requirements as
given in the EMC Directive 2014/30/EU. The certificate applies to the tested sample above mentioned only and
shall not imply an assessment of the whole production.

Authorized Signer:

Issued Date: June.29nd, 2016