0% found this document useful (0 votes)
50 views2 pages

CMC 310 Technical Data ENU

The CMC 310 is a 3-phase current and voltage test set designed for manual testing of protection devices. It has current outputs up to 32A and voltage outputs up to 300V. It is lightweight and compact, making it suitable for distribution and industrial system testing. It can also be upgraded to allow automated PC-based testing.

Uploaded by

sameershahzan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
50 views2 pages

CMC 310 Technical Data ENU

The CMC 310 is a 3-phase current and voltage test set designed for manual testing of protection devices. It has current outputs up to 32A and voltage outputs up to 300V. It is lightweight and compact, making it suitable for distribution and industrial system testing. It can also be upgraded to allow automated PC-based testing.

Uploaded by

sameershahzan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

CMC 

310

CMC 310: 3 Phase Current + 3 Phase Voltage Test Set

The CMC  310 is specifically designed for manual three-phase testing of protection and
measurement devices. The lightweight and compact design makes the CMC 310 particularly
suitable for testing distribution and industrial systems. If automated testing is requested, a
CMC 310 can be upgraded to a CMC 353 at any time which then can be operated by the PC
based Test Universe software.
Operation: CMControl

Technical Data1

Current generators Voltage generators


Setting range 3-phase AC (L-N) 3 x 0 ... 32 A Setting Range 3-phase AC (L-N) 3 x 0 ... 300 V
1-phase AC (L-L) 1 x 0 ... 32 A 1-phase AC (L-N) 1 x 0 ... 300 V
1-phase AC (LL-LN) 1 x 0 ... 64 A 1-phase AC (L-L) 1 x 0 ... 600 V
DC (LL-LN) 1 x 0 ... ±90 A DC (L-N) 3 x 0 ... ±300 V
Power 2, 3 3-phase AC (L-N) 3 x 430 VA typ. at 25 A Power 3 3-phase AC (L-N) 3 x 100 VA typ. at 100 ... 300 V
3 x 250 W guar. at 20 A 3 x 85 VA guar. at 85 ... 300 V
1-phase AC (L-L) 1 x 870 VA typ. at 25 A 1-phase AC (L-N) 1 x 200 VA typ. at 100 ... 300 V
1 x 530 W guar. at 20 A 1 x 150 VA guar. at 75 ... 300 V
1-phase AC (LL-LN) 1 x 700 W typ. at ±40 A 1-phase AC (L-L) 1 x 275 VA typ. at 200 ... 600 V
1 x 500 W guar. at ±40 A 1 x 250 VA guar. at 200 ... 600 V
DC (L-N) 1 x 420 W typ. at ±300 V
Output power (typ.) / VA

1 x 360 W guar. at ±300 V


900 1-phase AC (L-L)

600 1-phase AC (LL-LN) Output power (typ.) / VA 1-phase AC (L-L)


300
250 1-phase AC (L-N)
300 3-phase AC (L-N) 200
150 3-phase AC (L-N)
0 100
0 10 20 30 40 50 60 70 50
Output current / A 0
0 100 200 300 400 500 600
Accuracy 4 Error < 0.05 % rd. 5 + 0.02 % rg. 5 typ. Output voltage / V
Error < 0.15 % rd. + 0.05 % rg. guar.
Accuracy Error < 0.03 % rd. 5 + 0.01 % rg. 5 typ.
Distortion (THD+N) 6 < 0.05 % typ., < 0.15 % guar.
at 0 ... 300 V
Resolution 1 mA
Error < 0.08 % rd. + 0.02 % rg. guar.
Max. compliance voltage (L-N)/(L-L) 35 Vpk / 70 Vpk at 0 ... 300 V
Connection banana sockets 4 mm (0.16 in) banana sockets Distortion (THD+N) 6 0.015 % typ., < 0.05 % guar.
(32 A continuously)
Ranges 150 V / 300 V
Resolution 5 mV / 10 mV in range 150 V / 300 V
Connection 4 mm (0.16 in) banana sockets
Generators, general
Frequency Range sine signals 10 ... 599 Hz
Accuracy / drift ±0.5 ppm / ±1 ppm
Resolution < 5 µHz
Phase Angle range -360° ... +360°
Resolution 0.001°
Error at 50 / 60 Hz Voltage: 0.02° typ., < 0.1° guar.
Current: 0.05° typ., < 0.2° guar. 4

1
All data specified are guaranteed, except where indicated otherwise.
OMICRON guarantees the specified data for one year after factory calibration,
within 23 °C ±5 °C (73 °F ±10 °F) in the frequency range from 10 to 100 Hz and
after a warm-up phase > 25 minutes
2
Typical AC values valid for inductive loads (e.g. e/m relays)
3
Continuous operation with full output power possible for 15 minutes
4
Rload: 0 ... 0.5 Ω
5
rd. = reading, rg. = range
6
THD+N: Values at 50/60 Hz, > 1 A / 20 V with 20 kHz bandwidth
Technical Data CMC 310 (continued)
Auxiliary DC supply Miscellaneous
Voltage ranges 0 ... 264 VDC, 0.2 A / 0 ... 132 VDC, Weight 13.1 kg (28.9 lbs)
0.4 A / 0 ... 66 VDC, 0.8 A Dimensions 343 x 145 x 390 mm (13.6 x 5.7 x 15.4 in)
Power Max. 50 W (W x H x D, without handle)
Accuracy Error < 2 % typ., < 5 % guar. CMControl P connection One PoE 2 Ethernet port:
Binary inputs • 10/100/1000 Base-TX
Number 6 • IEEE 802.3af compliant (Class 2, 6.49 W)
Signal indication (LED) > 42 V for voltage and current outputs and AUX DC
Trigger criteria Toggling of potential-free contacts or DC voltage
compared to threshold voltage Connection to ground (earth) 4 mm (0.16 in) banana socket (rear side)
Input characteristics 0 ... ±300 VDC threshold or potential-free Hardware diagnostics Self diagnostics upon each start-up
Ranges 20 V / 300 V Galvanically separated groups The following groups are galvanically separated from
Resolution of threshold 50 mV (0 ... 20 V), 500 mV (20 V ... 300 V) each other: mains, voltage amplifier output, current
amplifier output, auxiliary DC supply, binary/analog
Sample rate 10 kHz (resolution 100 µs)
input
Time stamping accuracy ±0.00015 % of reading ±70 µs
Protection All current and voltage outputs are fully overload and
Max. measuring time Infinite short circuit proof and protected against external
Debounce / Deglitch time 0 ... 25 ms / 0 ... 25 ms high-voltage transient signals and over temperature
Counting function < 3 kHz at pulse width > 150 µs Certifications
Galvanic isolation 3 galvanically isolated groups (2+2+2)
Max. input voltage CAT IV / 150 V, CAT III / 300 V
Trigger on overload
Supported generators Current generators
Timer accuracy Error < 1 ms
Binary outputs, relays
Type Potential-free relay contacts, software controlled Developed and manufactured under an ISO 9001
Number 4 registered system
Break capacity AC Vmax: 300 VAC / Imax: 8 A / Pmax: 2000 VA
Break capacity DC Vmax: 300 VDC / Imax: 8 A / Pmax: 50 W
Power supply
Ordering Information
Nominal input voltage  100 – 240 VAC, 1-phase
Permissible input voltage 85 ... 264 VAC CMC 310 with CMControl P
Nominal frequency 50/60 Hz VE003001 CMC 310 with CMControl P
Permissible frequency range 45 ... 65 Hz
Power consumption 1.7 kVA at 115 V / 2.3 kVA at 230 V
CMC 310 for tablet control
Rated current 12 A at 115 V / 10 A at 230 V
VE003002 CMC 310 with CMControl P App activation key (for
Connection Standard AC socket (IEC 60320)
Environmental conditions
tablet control)
Operation temperature 1 0 ... +50 °C (+32 ... +122 °F)
Storage temperature -25 ... +70 °C (-13 ... +158 °F) Upgrade to CMC 353 with CMControl P
Humidity range Relative humidity 5 ... 95 %, non-condensing VEHO3002 Upgrade from “CMC 310 with CMControl P” to
Vibration IEC 60068-2-6 (20 m/s2 at 10 ... 150 Hz) “CMC 353 with CMControl P”
Shock IEC 60068-2-27 (15 g/11 ms half-sine)
Safety standards, electromagnetic compatibility
Upgrade to CMC 353 for tablet control
EMC The product adheres to the electromagnetic compat-
ibility (EMC) Directive 2004/108/EC (CE conform). VEHO3001 Upgrade from “CMC 310 with CMControl P App
International IEC 61326-1; IEC 61000-6-4; IEC 61000-3-2/3 activation key” to “CMC 353 with CMControl P App
USA FCC Subpart B of Part 15 Class A activation key”
Safety The product adheres to the low voltage Directive
2006/95/EC (CE conform).
Upgrade to CMC 353 with Test Universe software
International / USA IEC 61010-1 / UL 61010-1
Canada CAN/CSA-C22.2 No 61010-1-04 VEHO3003 Upgrade from CMC 310 (with CMControl P or
CMControl P App activation key) to CMC 353 + Test
Universe software (Basic Package)

For an operational temperature above +30 °C (+86 °F) a duty cycle of down to


1

50 % may apply.


PoE = Power over Ethernet