HW/HC004/005/006 Series DC-DC Power Module
HW/HC004/005/006 Series DC-DC Power Module
Features
RoHS Compliant Compliant to RoHS EU Directive 2011/65/EU (Z versions)
Compliant to RoHS EU Directive 2011/65/EU under
exemption 7b (Lead solder exemption). Exemption 7b
will expire after June 1, 2016 at which time this produc
twill no longer be RoHS compliant (non-Z versions)
Delivers up to 6A Output current
5V (4A), 3.3V (5A), 2.5V – 1.0V (6A each)
High efficiency – 89% at 5.0V full load
Low Output voltage- supports migration to future IC
supply voltages down to 1.0V
Applications Low output ripple and noise
Wireless Networks Small Size and low profile
Distributed power architectures 47.2mm x 29.5mm x 8.5mm
Optical and Access Network Equipment (1.86 x 1.16 x 0.335 in)
Enterprise Networks Surface mount or Through hole (TH)
Latest generation IC’s (DSP, FPGA, ASIC) and Remote On/Off
Microprocessor powered applications
Output overcurrent/Over voltage protection
Over temperature protection
Options Single Tightly regulated output
Remote On/Off logic (positive or negative)
Output voltage adjustment trim 10%
Surface Mount (-S Suffix)
Wide operating temperature range (-40°C to 85°C)
Additional Vout+ pin (-3 Suffix)
Meets the voltage insulation requirements for ETSI 300-
132-2 and complies with and is Licensed for Basic
Insulation rating per EN 60950
CE mark meets 73/23/EEC and 93/68/EEC directives§
UL* 60950-1Recognized, CSA† C22.2 No. 60950-1-03
Certified, and VDE‡ 0805:2001-12 (EN60950-1) Licensed
ISO** 9001 and ISO 14001 certified manufacturing
facilities
Description
The HW/HC series power modules are isolated dc-dc converters that operate over a wide input voltage range of 18 to 36
Vdc (HC) or 36 to 75 Vdc (HW) and provide one precisely regulated output. The output is fully isolated from the input,
allowing versatile polarity configurations and grounding connections. The modules exhibit high efficiency, e.g. typical
efficiency of 87% 3.3V/5A, 86% at 2.5V/6A. Built-in filtering for both input and output minimizes the need for external
filtering. These open frame modules are available either in surface-mount (-S) or in through-hole form.
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions.
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This power module can be used in a wide variety of applications, ranging from simple standalone operation to being part
of complex power architecture. To preserve maximum flexibility, internal fusing is not included; however, to achieve
maximum safety and system protection, always use an input line fuse. The safety agencies require a fast-acting fuse with
a maximum rating of 3A (see Safety Considerations section). Based on the information provided in this data sheet on inrush
energy and maximum dc input current, the same type of fuse with a lower rating can be used. Refer to the fuse
manufacturer’s data sheet for further information.
October 2, 2015 ©2012 General Electric Company. All rights reserved. Page 2
GE Data Sheet
5V, 3.3V
Output Voltage Set-point 2.5V, 2.0V, VO, set -1.0 +1.0 % VO, nom
1.8V, 1.5V
(VIN=VIN,nom, IO=IO, max, Tref=25°C) 1.2V, 1.0V VO, set -1.25 +1.25 % VO, nom
Output Voltage All VO -3.0 +3.0 % VO, nom
(Over all operating input voltage, resistive load,
and temperature conditions until end of life)
Adjustment Range All VO -10.0 +10.0 % VO, nom
Selected by external resistor
Output Regulation
Line (VIN=VIN, min to VIN, max) All 10 mV
Load (IO=IO, min to IO, max) All 15 mV
Temperature (Tref=TA, min to TA, max) All 1.00 %
Output Ripple and Noise on nominal output
(VIN=VIN, nom and IO=IO, min to IO, max)
October 2, 2015 ©2012 General Electric Company. All rights reserved. Page 3
GE Data Sheet
Isolation Specifications
Parameter Symbol Min Typ Max Unit
Isolation Capacitance Ciso 200 pF
Isolation Resistance Riso 10 MΩ
General Specifications
Parameter Min Typ Max Unit
Calculated MTBF (for HW005A0F1-S in accordance with Lucent RIN 6:
>4,000,000 Hours
IO=80% of IO, max, TA=25°C, airflow=1m/s)
Weight 13 g (oz.)
October 2, 2015 ©2012 General Electric Company. All rights reserved. Page 4
GE Data Sheet
Feature Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions.
See Feature Descriptions for additional information.
October 2, 2015 ©2012 General Electric Company. All rights reserved. Page 5
GE Data Sheet
Characteristic Curves
The following figures provide typical characteristics for the HW004A0A (5.0V, 4A) at 25ºC. The figures are identical for either
positive or negative Remote On/Off logic.
90 5
88
86 4
82 3
80 V I = 36V
V I = 54V 2 3.0 m/s (600 ft./min.)
78
V I = 75V 2.0 m/s (400 ft./min.)
76
1.0 m/s (200 ft./min.)
74 1 NATURAL CONVECTION
72
70 0
0 1 2 3 4 0 10 20 30 40 50 60 70 80 90 100 110
VO (V) (2V/div)
VON/OFF(V) (5V/div)
IO (A) (1A/div)
October 2, 2015 ©2012 General Electric Company. All rights reserved. Page 6
GE Data Sheet
90 6
88
5
86
82
80 V I = 36V 3
3.0 m/s (600 ft./min.)
V I = 54V
78 2.0 m/s (400 ft./min.)
V I = 75V 2
76 1.0 m/s (200 ft./min.)
NATURAL CONVECTION
74 1
72
70 0
0 1 2 3 4 5 0 10 20 30 40 50 60 70 80 90 100 110
VO (V) (1V/div)
VON/OFF(V) (5V/div)
IO (A) (2A/div)
October 2, 2015 ©2012 General Electric Company. All rights reserved. Page 7
GE Data Sheet
80
4
78
76 V I = 36V 3
74 V I = 54V
2.0 m/s (400 ft./min.)
V I = 75V 2
72 1.0 m/s (200 ft ./min.)
70 1 NATURAL CONVECTION
68
0 1 2 3 4 5 6
0
0 10 20 30 40 50 60 70 80 90 100 110
OUTPUT VOLTAGE
VO (V) (1V/div)
OUTPUT VOLTAGE,
VO (V) (20mV/div)
INPUT VOLTAGE,
VIN (V) (50V/div)
VO (V) (1V/div)
VON/OFF(V) (5V/div)
IO (A) (2A/div)
October 2, 2015 ©2012 General Electric Company. All rights reserved. Page 8
GE Data Sheet
80
4
78
76 V I = 36V 3
74 V I = 54V
2.0 m/ s (400 ft ./min.)
V I = 75V 2
72 1.0 m/ s (200 f t./min.)
70 1 NATURAL CONVECTION
68
0 1 2 3 4 5 6
0
0 10 20 30 40 50 60 70 80 90 100 110
OUTPUT VOLTAGE
VO (V) (1V/div)
OUTPUT VOLTAGE,
VO (V) (20mV/div)
INPUT VOLTAGE,
VIN (V) (50V/div)
VO (V) (1V/div)
VON/OFF(V) (5V/div)
IO (A) (2A/div)
October 2, 2015 ©2012 General Electric Company. All rights reserved. Page 9
GE Data Sheet
78 4
76
3
74
2.0 m/ s (400 f t./ min.)
72 2
V I = 36V 1.0 m/ s (200 f t./ min.)
70 V I = 54V NATURAL CONVECTION
1
68 V I = 75V
66 0
0 1 2 3 4 5 6 0 10 20 30 40 50 60 70 80 90 100 110
VO (V) (500mV/div)
INPUT VOLTAGE, OUTPUT VOLTAGE
OUTPUT VOLTAGE,
VO (V) (20mV/div)
October 2, 2015 ©2012 General Electric Company. All rights reserved. Page 10
GE Data Sheet
78
4
76
74 3
VO (V) (500mV/div)
INPUT VOLTAGE, OUTPUT VOLTAGE
OUTPUT VOLTAGE,
VO (V) (20mV/div)
October 2, 2015 ©2012 General Electric Company. All rights reserved. Page 11
GE Data Sheet
80 7
78
6
76
72
4
70
68 V I = 36V 3
V I = 54V 3.0 m/s (600 ft./min.)
66
V I = 75V 2 2.0 m/ s (400 ft./min.)
64 1.0 m/ s (200 f t./ min.)
62 1 NATURAL CONVECTION
60
0 1 2 3 4 5 6 0
0 10 20 30 40 50 60 70 80 90 100 110
VO (V) (500mV/div)
INPUT VOLTAGE, OUTPUT VOLTAGE
OUTPUT VOLTAGE,
VO (V) (20mV/div)
October 2, 2015 ©2012 General Electric Company. All rights reserved. Page 12
GE Data Sheet
80 7
78
6
76
72
4
70
68 3
VI = 36V 3.0 m/s (600 ft./min.)
66
VI = 54V 2 2.0 m/ s (400 ft./min.)
64 1.0 m/ s (200 f t./ min.)
VI = 75V
62 1 NATURAL CONVECTION
60
0 1 2 3 4 5 6 0
0 10 20 30 40 50 60 70 80 90 100 110
VO (V) (500mV/div)
INPUT VOLTAGE, OUTPUT VOLTAGE
OUTPUT VOLTAGE,
VO (V) (20mV/div)
October 2, 2015 ©2012 General Electric Company. All rights reserved. Page 13
GE Data Sheet
0
0 10 20 30 40 50 60 70 80 90 100 110
VO (V) (2V/div)
VON/OFF(V) (5V/div)
IO (A) (1A/div)
October 2, 2015 ©2012 General Electric Company. All rights reserved. Page 14
GE Data Sheet
0
0 10 20 30 40 50 60 70 80 90 100 110
VO (V) (1V/div)
VON/OFF(V) (5V/div)
IO (A) (2A/div)
October 2, 2015 ©2012 General Electric Company. All rights reserved. Page 15
GE Data Sheet
CS 220μF
E.S.R.<0.1
33μF
(ESR<0.7 at 100kHz), mounted close to the power module
@ 20°C 100kHz helps ensure the stability of the unit. Consult the factory for
further application guidelines.
Vin-
Safety Considerations
NOTE: Measure input reflected ripple current with a simulated For safety-agency approval of the system in which the
source inductance (LTEST) of 12μH. Capacitor CS offsets
possible battery impedance. Measure current as shown power module is used, the power module must be installed
above.
in compliance with the spacing and separation
Figure 61. Input Reflected Ripple Current Test Setup. requirements of the end-use safety agency standard, i.e.,
COPPER STRIP
UL 60950-1-3, CSA C22.2 No. 60950-00, and VDE
0805:2001-12 (IEC60950-1).
VO (+) RESISTIVE
LOAD
If the input source is non-SELV (ELV or a hazardous voltage
greater than 60 Vdc and less than or equal to 75Vdc), for
1uF . 10uF SCOPE
the module’s output to be considered as meeting the
V O (–) requirements for safety extra-low voltage (SELV), all of the
following must be true:
GROUND PLANE The input source is to be provided with reinforced insulation
NOTE: All voltage measurements to be taken at the module
from any other hazardous voltages, including the ac mains.
terminals, as shown above. If sockets are used then
Kelvin connections are required at the module terminals One VIN pin and one VOUT pin are to be grounded, or both the
to avoid measurement errors due to socket contact input and output pins are to be kept floating.
resistance.
Figure 62. Output Ripple and Noise Test Setup. The input pins of the module are not operator accessible.
Another SELV reliability test is conducted on the whole system
(combination of supply source and subject module), as
Rdistribution Rcontact Rcontact Rdistribution required by the safety agencies, to verify that under a single
Vin+ Vout+ fault, hazardous voltages do not appear at the module’s
output.
RLOAD
Note: Do not ground either of the input pins of the module
VIN VO
without grounding one of the output pins. This may
allow a non-SELV voltage to appear between the
Rdistribution Rcontact Rcontact Rdistribution output pins and ground.
Vin- Vout-
The power module has extra-low voltage (ELV) outputs
when all inputs are ELV.
NOTE: All voltage measurements to be taken at the module
terminals, as shown above. If sockets are used then For input voltages exceeding –60 Vdc but less than or equal
Kelvin connections are required at the module terminals
to avoid measurement errors due to socket contact
to –75 Vdc, these converters have been evaluated to the
resistance. applicable requirements of BASIC INSULATION between
secondary DC MAINS DISTRIBUTION input (classified as
Figure 63. Output Voltage and Efficiency Test Setup. TNV-2 in Europe) and unearthed SELV outputs.
VO. IO
"All flammable materials used in the manufacturing of
Efficiency = x 100 % these modules are rated 94V-0 and UL60950 A.2 for
VIN. IIN
reduced thicknesses.
The input to these units is to be provided with a maximum
3A fast-acting fuse in the unearthed lead."
Feature Description
Remote On/Off
Two remote on/off options are available. Positive logic turns
the module on during a logic high voltage on the ON/OFF
October 2, 2015 ©2012 General Electric Company. All rights reserved. Page 16
GE Data Sheet
pin, and off during a logic low. Negative logic remote Over Voltage Protection
On/Off, device code suffix “1”, turns the module off during a
logic high and on during a logic low. The output overvoltage protection consists of circuitry that
internally clamps the output voltage. If a more accurate
To maintain compatibility with LW series power modules output overvoltage protection scheme is required then this
the Remote On/Off pin is optional for the TH (through hole) should be implemented externally via use of the remote
version. Standard TH modules have no On/Off pin fitted. TH on/off pin.
modules ordered with device code suffix “1” are negative
logic with the On/Off pin fitted. Over Temperature Protection
To provide protection in a fault condition, the unit is
VIN(+)
equipped with a thermal shutdown circuit. The unit will
shutdown if the overtemperature threshold of 125 oC is
exceeded at the thermal reference point Tref . Once the unit
VO goes into thermal shutdown it will then wait to cool before
Ion/off
ON/OFF attempting to restart.
Output Voltage Programming
Von/off
COM Trimming allows the output voltage set point to be
increased or decreased, this is accomplished by connecting
an external resistor between the TRIM pin and either the
VIN(-) VO(+) pin or the VO(-) pin (COM pin) .
VIN(+) VO(+)
October 2, 2015 ©2012 General Electric Company. All rights reserved. Page 17
GE Data Sheet
Nominal 5V, 3.3V, 2.5V, 2.0V, 1.8V, & 1.5V modules: Rtrim-down = 249.39 k
To trim up the output of a nominal 3.3V module
511
(HW005A0F) to 3.63V
Rtrim-down = - 6.11 k
% ∆% = 10
390
Rtrim-down = - 4.90 k
%
5.11VO(100+%) 511
Rtrim-up = - - 6.11 k
1.225% %
5.11VO(100+%) 346
Rtrim-up = - - 4.46 k
1.225% %
5.11VO(100+%) 390
Rtrim-up = - - 4.90 k
1.225% %
Examples:
To trim down the output of a nominal 5.0V module
(HW004A0A) to 4.90V
October 2, 2015 ©2012 General Electric Company. All rights reserved. Page 18
GE Data Sheet
module power dissipation, and the need for increased 0.68uF 0.68uF 0.68uF
90
80
70
60
EN 55022 Class B Conducted Average dBuV
50
40
30
Level (dBµV)
20
10
EMC Considerations
The figure 67 shows a suggested configuration to meet the
conducted emission limits of EN55022 Class B.
October 2, 2015 ©2012 General Electric Company. All rights reserved. Page 19
GE Data Sheet
29.5
(1.162)
2.54
(0.100)
min stand-off 8.50
Side View height (0.335)
MAX
0.5
(.020)
max
compliance
October 2, 2015 ©2012 General Electric Company. All rights reserved. Page 20
GE Data Sheet
29.5
(1.162)
Side View
Pin Function
1 2 9
1 Vout +
2 Vout - 26.16
9 Trim
(1.031)
11 On/Off
17 Vin -
18 17 11
18 Vin +
1.65 5.00
(0.065) (0.197)
3.63 35.00
(0.143) (1.379)
October 2, 2015 ©2012 General Electric Company. All rights reserved. Page 21
GE Data Sheet
Recommended Pad Layout for Surface Mount and Through Hole Module
Dimensions are in millimeters and (inches).
Tolerances: x.x mm 0.5 mm (x.xx in. 0.02 in.) [unless otherwise indicated]
x.xx mm 0.25 mm (x.xxx in 0.010 in.)
Pin Function
1 Vout +
2 Vout -
Standard = No Pin
3
Optional = Vout +
9 Trim
11 On/Off
17 Vin -
18 Vin +
Pin Function
1 Vout +
2 Vout -
9 Trim
11 On/Off
17 Vin -
18 Vin +
October 2, 2015 ©2012 General Electric Company. All rights reserved. Page 22
GE Data Sheet
Packaging Details
The surface mount versions of the HW005 family are also available in tape & reel (suffix –SR) as an option. Detailed of tape
dimensions are shown below. Modules are shipped in quantities of 115 per reel.
Tape Dimensions
Dimensions are in millimeters and (inches).
9.02
4.00 40.00 (0.355)
PICK POINT (0.157) (1.575)
Reel Dimensions
Outside diameter: 330.2 mm (13.00”)
Inside diameter: 177.8 mm (7.00”)
Tape Width: 72.00 mm (2.834”)
October 2, 2015 ©2012 General Electric Company. All rights reserved. Page 23
GE Data Sheet
October 2, 2015 ©2012 General Electric Company. All rights reserved. Page 24
GE Data Sheet
Surface Mount Information (continued) The surface mountable modules in the HW005 family
use our newest SMT technology called “Column Pin” (CP)
connectors. Fig 71 shows the new CP connector before
and after reflow soldering onto the end-board assembly.
24.2
COG
HW005 Board
12.7
Insulator
14.7
Solder Ball
8.0
19.0 9.5
Figure 71. Column Pin Connector Before and After
Reflow Soldering.
Note: All dimensions in mm.
Figure 70. Pick and Place Location. The CP is constructed from a solid copper pin with an
integral solder ball attached, which is composed of
tin/lead (Sn/Pb) solder. The CP connector design is able
Z Plane Height to compensate for large amounts of co-planarity and
The ‘Z’ plane height of the pick and place location is still ensure a reliable SMT solder joint.
7.50mm nominal with an RSS tolerance of +/-0.25 mm.
Typically, the eutectic solder melts at 183oC, wets the
Nozzle Recommendations land, and subsequently wicks the device connection.
Sufficient time must be allowed to fuse the plating on the
The module weight has been kept to a minimum by connection to ensure a reliable solder joint. There are
using open frame construction. Even so, they have a several types of SMT reflow technologies currently used
relatively large mass when compared with conventional in the industry. These surface mount power modules
SMT components. Variables such as nozzle size, tip style, can be reliably soldered using natural forced convection,
vacuum pressure and placement speed should be IR (radiant infrared), or a combination of convection/IR.
considered to optimize this process. For reliable soldering the solder reflow profile should be
The minimum recommended nozzle diameter for reliable established by accurately measuring the modules CP
operation is 6mm. The maximum nozzle outer diameter, connector temperatures.
which will safely fit within the allowable component 300
spacing, is 9 mm.
P eak Temp 235oC
Oblong or oval nozzles up to 11 x 9 mm may also be 250
used within the space available. Co o ling
Heat zo ne zo ne
200
REFLOW TEMP (C)
So ak zo ne
Reflow Soldering Information 100 30-240s Tlim above
205oC
The HW005 family of power modules is available for
50 P reheat zo ne
either Through-Hole (TH) or Surface Mount (SMT) max 4oCs -1
soldering. These power modules are large mass, low
0
thermal resistance devices and typically heat up slower
than other SMT components. It is recommended that REFLOW TIME (S)
the customer review data sheets in order to customize Figure 72. Recommended Reflow Profile
the solder reflow profile for each application board
assembly.
The following instructions must be observed when SMT
soldering these units. Failure to observe these
instructions may result in the failure of or cause damage
to the modules, and can adversely affect long-term
reliability.
October 2, 2015 ©2012 General Electric Company. All rights reserved. Page 25
GE Data Sheet
Surface Mount Information (continued) packages will be a minimum of 12 months from the bag
seal date, when stored at the following conditions: < 40°
240 C, < 90% relative humidity.
235 Post Solder Cleaning and Drying Considerations
230 Post solder cleaning is usually the final circuit-board
MAX TEMP SOLDER (C)
225
assembly process prior to electrical board testing. The
result of inadequate cleaning and drying can affect both
220 the reliability of a power module and the testability of
215 the finished circuit-board assembly. For guidance on
appropriate soldering, cleaning and drying procedures,
210
refer to GE Board Mounted Power Modules: Soldering and
205 Cleaning Application Note (AP01-056EPS).
300
200 Per J-STD-020 Rev. C
0 10 20 30 40 50 60 Peak Temp 260°C
250
TIME LIMIT (S)
Power Systems will comply with J-STD-020 Rev. C Solder Ball and Cleanliness Requirements
(Moisture/Reflow Sensitivity Classification for
The open frame (no case or potting) power module will
Nonhermetic Solid State Surface Mount Devices) for both
meet the solder ball requirements per J-STD-001B. These
Pb-free solder profiles and MSL classification procedures.
This standard provides a recommended forced-air- requirements state that solder balls must neither be
loose nor violate the power module minimum electrical
convection reflow profile based on the volume and
spacing.
thickness of the package (table 4-2). The suggested Pb-
free solder paste is Sn/Ag/Cu (SAC). The recommended The cleanliness designator of the open frame power
linear reflow profile using Sn/Ag/Cu solder is shown in module is C00 (per J specification).
Figure. 74.
MSL Rating
The HW/HC series SMT modules have a MSL rating of 2A.
October 2, 2015 ©2012 General Electric Company. All rights reserved. Page 26
GE Data Sheet
Ordering Information
Please contact your GE Sales Representative for pricing, availability and optional features.
Table 1. Device Codes
Input Output Output Remote Connector
Product codes Comcodes
Voltage Voltage Current On/Off Logic Type
HW004A0A-S 48 Vdc 5.0V 4A Positive SMT 108968272
HW004A0A-SZ 48 Vdc 5.0V 4A Positive SMT 109100245
HW004A0A1 48 Vdc 5.0V 4A Negative Through-Hole 108965476
HW004A0A1-S 48 Vdc 5.0V 4A Negative SMT 108960634
HW004A0A1Z 48 Vdc 5.0V 4A Negative Through-Hole CC109102002
HW004A0A1-SB 48 Vdc 5.0V 4A Negative SMT 108980525
HW004A0A1-SZ 48 Vdc 5.0V 4A Negative SMT 109100237
HW005A0F-S 48 Vdc 3.3V 5A Positive SMT 108968678
HW005A0F-SZ 48 Vdc 3.3V 5A Positive SMT 109100261
HW005A0F-SR39* 48 Vdc 3.3V 5A Positive SMT (tape & reel) 108986951
HW005A0F1 48 Vdc 3.3V 5A Negative Through-Hole 108967779
HW005A0F1Z 48 Vdc 3.3V 5A Negative Through-Hole CC109107125
HW005A0F1-S 48 Vdc 3.3V 5A Negative SMT 108960667
HW005A0F1-SZ 48 Vdc 3.3V 5A Negative SMT 108995197
HW005A0F1-SRZ 48 Vdc 3.3V 5A Negative SMT (tape&reel) 109100253
HW005A0F1-S65* 48 Vdc 3.3V 5A Negative SMT 108987512
HW005A0F1-S65Z* 48 Vdc 3.3V 5A Negative SMT 108995206
HW006A0G1-SZ 48 Vdc 2.5V 6A Negative SMT 109100311
HW006A0D1-S 48 Vdc 2.0V 6A Negative SMT 108969676
HW006A0D1-SZ 48 Vdc 2.0V 6A Negative SMT 109100303
HW006A0Y1-S 48 Vdc 1.8V 6A Negative SMT 108960782
HW006A0Y1-SZ 48 Vdc 1.8V 6A Negative SMT 109100344
HW006A0P1-SZ 48 Vdc 1.2V 6A Negative SMT 109100336
HC004A0A1-S 24 Vdc 5.0V 4A Negative SMT 108960642
HC004A0A1-SZ 24 Vdc 5.0V 4A Negative SMT 108996113
HC005A0F1-S 24 Vdc 3.3V 5A Negative SMT 108960659
HC005A0F1-SZ 24 Vdc 3.3V 5A Negative SMT 108996121
October 2, 2015 ©2012 General Electric Company. All rights reserved. Page 27
GE Data Sheet
* Please contact GE for availability of these options, samples, minimum order quantity and lead times
Contact Us
For more information, call us at
USA/Canada:
+1 877 546 3243, or +1 972 244 9288
Asia-Pacific:
+86.021.54279977*808
www.gecriticalpower.com
GE Critical Power reserves the right to make changes to the product(s) or information contained herein without notice, and no
liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such
product(s) or information.
October 2, 2015 ©2012 General Electric Company. All International rights reserved. Version 1.2