The document provides instructions for installing and setting up the NEMTEK Connect Device Gateway 2G to remotely monitor and control supported NEMTEK devices through the NEMTEK Connect platform and app. It connects to NEMTEK Druid D25 and D28 energizers and allows checking device status via the LEDs. The hardware installation section provides details on mounting the gateway board, connecting it to the energizer and battery, and setting the energizer address.

Uploaded by

neumann Cassien
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
140 views6 pages

Nemtek CDG2 GManual Druid 2 X

The document provides instructions for installing and setting up the NEMTEK Connect Device Gateway 2G to remotely monitor and control supported NEMTEK devices through the NEMTEK Connect platform and app. It connects to NEMTEK Druid D25 and D28 energizers and allows checking device status via the LEDs. The hardware installation section provides details on mounting the gateway board, connecting it to the energizer and battery, and setting the energizer address.

Uploaded by

neumann Cassien
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

NEMTEK Connect

Device Gateway 2G
Instruction Manual for Druid D2x
Foreword

Thank you for choosing our product. The NEMTEK Connect Device Gateway 2G is designed
and manufactured to provide many years of reliable use, if installed and maintained correctly.
The guidelines provided in this manual will assist you with the basic operation and maintenance
of your unit. Currently this product is designed and manufactured in South Africa for South African
and international markets. More information on our products and general information is available
on our website at: http://www.nemtek.com

The NEMTEK Connect Device Gateway 2G provides connectivity to your supported NEMTEK
devices by allowing for connectivity to the NEMTEK Connect platform. Together with the
NEMTEK Connect App, you can remotely monitor and control your NEMTEK devices, as well
as receive notifications and alerts.

Supported Nemtek Devices

The NEMTEK Connect DG works with the following Nemtek products:

Druid D25, D28

Note: This list may be changed without prior notice.

Please see the hardware installation section for more details on how to set up your specific device.

Hardware Overview

The NEMTEK Connect DG features:

2G GSM GPRS Modem

Nano SIM Card slot

SMA (Female) Connector, supports many SMA (Male) GSM Antennas

D2x comms support for Nemtek Druid D2x range

1 www.nemtek.com
User LEDs Antenna User
Connector Button

-
User LEDs

+
Board Connections

SIM
Card

www.nemtek.com
Slot
+ -
Energizer
Power Out
To Energizer
Comm Port
To Energizer
Battery

2
Hardware Installation

The NEMTEK Connect DG has been designed to be installed onto the battery brace inside
of the enclosure of a supported NEMTEK energizer.

To install the DG, unplug the energizer from mains and disconnect the energizer’s battery
leads from the battery. You may need to remove the battery brace to get better access to
the battery terminals to remove and plug in the cables onto the battery terminals.

Plug the energizer battery leads directly into the Battery Power Out terminals of the DG
board. Be careful to ensure you connect the correct polarity wires to the correct terminal.
Make sure the terminal connectors are plugged in completely and firmly onto the battery
terminals on the board.

Connect the furthest away battery wire to the battery. This is usually the negative terminal
and wire, unless the battery is orientated differently. Take care to ensure you connect the
correct polarity wires to the correct battery terminals. Do not connect the second wire yet,
as this will apply power to both the DG and energizer.

Make sure the battery is firmly in place and screw the battery brace back over the battery.
Be sure that no wires or obstacles are between the battery brace and the battery and that
the battery brace goes over the battery without any force, otherwise this may cause a crack
in the battery which could cause a leak of battery acid.

Align and screw in the DG board on the battery brace. Two screws are supplied for this
purpose.

Screw in the antenna. If your antenna has a lead, make sure it is routed outside of the
enclosure via the appropriate cable management ports, be careful to not get the cable caught
on the enclosure edge when screwing the lid back on.

Connect up the DG to your energizer as is necessary (see following section for details for
each of the supported Nemtek products).

Once everything is wired up and setup, plug in the second lead to the battery to power up
the system. Screw the lid of the enclosure back into place and plug the energizer back into
the mains. Reconnect the mains supply.

3 www.nemtek.com
Connecting to Supported Nemtek Products

Connecting to a Druid D2x Energizer

The Druid D2x (D25 and D28) is connected to the NEMTEK Connect DG via the data
ribbon cable included.
Connect the ribbon to the relevant connectors on the DG and the energizer.

Set the energizer up to network address number 1 using the keypad. This is done by entering
programming mode (INSTALLER_PIN*#) and the address change command (5101#),
then exit programming mode (*#).
-
+

+ —
Battery Leads
Energizer

Data
Ribbon Cable

LED Definitions
S1
Flashes Description: S3

0 GSM is off C1
S2
1 Searching for network
2 CSD Signal acquired
3 GPRS connection established --
Performing server connection process
S4 S5

C2 C3 C4
4 Connected to Server
C5

5 SIM Error Condition

www.nemtek.com 4
GUARANTEE & DISCLAIMER

The NEMTEK Connect DGM, manufactured by NEMTEK (Pty) Ltd, is guaranteed for a period of two years
from date of sale against defects due to faulty workmanship or materials. NEMTEK will, at its discretion,
either repair or replace a product that proves to be defective. NEMTEK guarantees that the product, when
properly installed and used in line with the specification as determined by NEMTEK from time to time,
will execute its function of generating a suitable potential.

NEMTEK (Pty) Ltd does not guarantee that the operation of the product will be uninterrupted and totally
error free. Faulty units must be returned to one of the NEMTEK Group outlets. The buyer shall pay all
shipping and other charges for the return of the product to NEMTEK or NEMTEK Security Warehouse.
Specifications may be altered without prior notification.

LIMITATION OF GUARANTEE

The guarantee does not apply to defects resulting from acts of God, modifications made by the buyer or
any third party, misuse, neglect, abuse, accident or mishandling.

EXCLUSIVE REMEDIES

The remedies provided herein are NEMTEK (Pty) Ltd’s sole liability and the buyer’s sole and exclusive
remedies for breach of warranty. NEMTEK shall not be liable for any special, incidental, consequential,
direct or indirect damages, whether based on contract, tort, or any other legal theory. The foregoing
guarantee is in lieu of any and all other guarantees, whether expressed, implied, or statutory, including
but not limited to guarantees of merchantability and suitability for a particular purpose.

COMPANY PROFILE

The NEMTEK Group of Companies manufacture and distribute intelligent electronic agricultural fencing
systems, security and perimeter control systems and have been involved in the security industry since
1990. We have our own research and development team, designing and manufacturing a full range of
globally competitive electric fence energizers and related products. NEMTEK is continually updating its
products according to South African and international standards in order to ensure the highest quality
products and continuous customer satisfaction.

CDGD2X 10/22 Rev.1.0