You are on page 1/ 22

english

A-G-247NW

Part.-No. 380090

Hand held terminal


Operating Instructions

Software version: from Version 8.05

L-BAL-E184-GB 2105 Index 003 Part.-No.


Operating Instructions A-G-247NW

Content
1 General notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.1 Structure of the operating instructions . . . . . . . . . . . . . . . . . . . . 3
1.2 Exclusion of liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.3 FCC / IC Statements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

2 Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

3 Product overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3.1 Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3.2 Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3.3 Disposal / recycling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

4 Structure of the terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6


4.1 Components / connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
4.2 Voltage supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
4.3 MODBUS (RS-485) interface . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

5 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
5.1 Display and operating elements of the terminal . . . . . . . . . . . . . 9

6 Programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
6.1 Overview mainmenu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
6.2 AM-MODBUS App's . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
6.2.1 Configuration Online . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
6.2.2 Auto Addressing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
6.2.3 Load Paramterset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
6.2.4 Device Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
6.3 AM-PEMIUM App's . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
6.3.1 Configuration Online . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
6.4 AXG Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
6.5 USB Filetransfer, only AM-MODBUS(-W) . . . . . . . . . . . . . . . . . . 16
6.6 USB COMPORT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
6.7 A-G-247 Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

7 Technical data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
7.1 Manufacturer reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
7.2 Service information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

L-BAL-E184-GB 2105 Index 003 Part.-No.


2/22
Operating Instructions A-G-247NW General notes

1 General notes
Compliance with the following instructions is mandatory to ensure the functionality and
safety of the product. If the following instructions given especially but not limited for
general safety, transport, storage, mounting, operating conditions, start-up, mainte-
nance, repair, cleaning and disposal / recycling are not observed, the product may not
operate safely and may cause a hazard to the life and limb of users and third parties.
Deviations from the following requirements may therefore lead both to the loss of the
statutory material defect liability rights and to the liability of the buyer for the product that
has become unsafe due to the deviation from the specifications.

1.1 Structure of the operating instructions


Before installation and start-up, read this manual carefully to ensure correct use!
We emphasize that these operating instructions apply to specific units only, and are in
no way valid for the complete system!
Use these operating instructions to work safely with and on the device. They contain
safety instructions that must be complied with as well as information that is required for
failure-free operation of the device.
Keep these operating instructions together with the device. It must be ensured that all
persons that are to work on the device can refer to the operating instructions at any time.

1.2 Exclusion of liability


To allow for future developments, construction methods and technical data given are
subject to alteration. We do not accept any liability for possible errors or omissions in the
information contained in data, illustrations or drawings provided.
We accept no liability for damage caused by misuse, incorrect use, improper use or as a
consequence of unauthorized repairs or modifications.

1.3 FCC / IC Statements

FCC Compliance (US)


This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions:(1) this device may not cause harmful interference, and(2) this device
must accept any interference received, including interference that may cause undesired
operation.

Note: This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can radiate radio fre-
quency energy and, if not installed and used in accordance with the instruction manual,
may cause harmful interference to radio communications. Operation of this equipment in
a residential area is likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.

L-BAL-E184-GB 2105 Index 003 Part.-No.


3/22
Operating Instructions A-G-247NW Safety instructions
FCC Warning
Changes or modifications not expressly approved by the party responsible for compli-
ance could void the user's authority to operate the equipment.

IC Compliance (Canada)
This device complies with Industry Canada licence-exempt RSS standard(s). Operation
is subject to the following two conditions: (1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may cause
undesired operation of the device.

Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils
radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1)
l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter
tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compro-
mettre le fonctionnement.

This Class A digital apparatus complies with Canadian ICES-003.


Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.

2 Safety instructions
Attention!
• These operating instructions are valid only in combination with the device's
operating instructions which can controlled by these terminal. The remarks
concerning safety, installation and connection described in those operating
instructions must be followed!
• Persons entrusted with the planning, installation, commissioning and maintenance
and servicing in connection with the device must have the corresponding
qualifications and skills for these jobs. In addition, they must be knowledgeable
about the safety regulations, EU directives, rules for the prevention of accidents
and the corresponding national as well as regional and in-house regulations.
• The equipment is to be used solely for the purposes specified and confirmed in the
order. Other uses which do not coincide with, or which exceed those specified will
be deemed unauthorised unless contractually agreed. Damages resulting from
such unauthorised uses will not be the liability of the manufacturer. The user will
assume sole liability.
• It is strictly forbidden for work to be carried out on any components while they are
connected to live voltage.
• The owner is obliged to ensure that the device is operated in perfect working order
only.
• Never clean electrical equipment with water or similar liquids.

L-BAL-E184-GB 2105 Index 003 Part.-No.


4/22
Operating Instructions A-G-247NW Product overview

3 Product overview
3.1 Function
Terminal for setting of compatible ZIEHL-ABEGG devices.
The connection to the member is made by a connecting cable (RS-485 interface) or
wirelessly by means of radio.
Parameter sets of devices with integrated AM-MODBUS(-W) type communication mod-
ule can be saved in the terminal and transferred to other devices.
It is possible to save and exchange parameter sets with a PC via the terminal’s USB
interface.

Information
The terminal software is continuously developed and improved.
ZIEHL-ABEGG will provide free firmware upgrades for downloading in future.

3.2 Storage
• The device must be stored in its original packaging in a dry and weather-proof
room.
• Avoid exposure to extreme heat and cold.
• Avoid over-long storage periods (we recommend a maximum of one year).

3.3 Disposal / recycling


Disposal must be carried out professionally and in an environmentally friendly way in
accordance with the respective national legal stipulations.
" Separate the materials by type and in an environmentally friendly way.
" If necessary, commission a specialist company with the waste disposal.

L-BAL-E184-GB 2105 Index 003 Part.-No.


5/22
Operating Instructions A-G-247NW Structure of the terminal

4 Structure of the terminal


4.1 Components / connection
Mini-B (5 pin)

3
+ 3,3 V
6
IRDA-RXD
1
IRDA-TXD

IRDA-SD

A
(D+) MODBUS
B (RS-485)
(D-)
5
GND

+5V
17.12.2012
v_a-g-247nw_spg.vsd

4
STOP 24V GND
A B
(D+) (D-)

1 Plug power supply unit


2 Connection voltage supply / USB interface for filetransfer
3 Connection to the terminal line-commutated. Do not connect the |24 V | at the terminal!
4 Terminal connection of compatible ZIEHL-ABEGG device
5 Rechargeable battery compartment lid
6 Mignon accumulators (NiMh 1.2 V)

4.2 Voltage supply


The voltage supply of the terminal is made by the accumulators internal.
The device switches off automatically if the plug power pack is left connected with fully
charged batteries and no key is pressed for about 1 minute.

Attention!
• Only rechargeable Mignon batteries (NiMh 1.2 V) may be used. These are
automatically loaded when the power supply unit is plugged-in.
• There is a risk of fire and explosion if non-rechargeable batteries are used and the
power supply unit is plugged in!
• It is only permissible to operate or load the terminal with the plug power pack
contained in the scope of supply.

L-BAL-E184-GB 2105 Index 003 Part.-No.


6/22
Operating Instructions A-G-247NW Structure of the terminal

4.3 MODBUS (RS-485) interface


The device comes equipped with a RS-485 interface for networking via MODBUS.
Conntection at: “A (D+)”, “B (D-)” and “GND”.

Example for devices with MODBUS connection and automatic addressing

A-G-247NW
+ 3,3 V

IRDA-RXD

IRDA-TXD

IRDA-SD

A
MODBUS
(RS-485)

(D+)
B
(D-)

GND

+5V

1 2
ECblue MODBUS ECblue MODBUS

3...63
Addressing

Addressing

Addressing

Addressing
MODBUS MODBUS MODBUS MODBUS
(RS-485) (RS-485) (RS-485) (RS-485)
A B A B A B A B
GND ID1 GND ID2 GND ID1 GND ID2
(D+) (D-) (D+) (D-) (D+) (D-) (D+) (D-)

04.03.2013
v_modbus_net_autoadr.vsd

The connection is made at the terminals: A (D+), B (D-) and GND


connection of the users via the terminals: A (D+), B (D-), GND and ID1 / ID2

Information
• You must ensure correct connection; i.e. “A (D+)” must also be connected on the
following devices to “A (D+)”. The same applies to “A (D+)”.
• In addition, a "GND" connection must be established, as dissimilar potential (over
10 V!) will lead to the destruction of the RS-485 interface (e.g. lightning).
• Make sure the distance from powerlines and motor wires is sufficient (min. 20 cm).
• A maximum of 63 users can be connected directly with each orther in automatic
adressing.
• Another 63 users are connected by a repeater in manual addressing (no
connection of connections “ID1”, “ID2”).
• When using the automatic addressing, no repeaters can be used because these
do not pass the signal through to the addressing.

L-BAL-E184-GB 2105 Index 003 Part.-No.


7/22
Operating Instructions A-G-247NW Structure of the terminal
Example for MODBUS connection

The data line must be conducted from one device to the next. No other type of wiring is allowed!
Always use only two wires of one lead (twisted pair) for the connection.

Recommended wire types


1. CAT5 / CAT7 cables
2. J-Y (St) 2x2x0.6 (telephone cable)
3. AWG22 (2x2 twisted pair)
Max. allowed wire length 1000 m (CAT5/7 500 m).

When using telephone cable with four cable cores, we recommend the following
allocation:
• A (D+) = red
• B (D-) = black
• ID1 - ID2 = yellow
• GND = white
Default interface parameter
• Baudrate = 19200
• Bits = 8
• Parity = Even
• Stop bits = 1
• Handshake = none
Information
• If any matters are unclear, please contact our V-STE support department for
control systems - ventilation technology. The information sheet “Network structure
of MODBUS” R-TIL08_01 contains detailed information about “MODBUS”.
• The MODBUS register description can be found on our homepage for down-
loading. Enter “MODBUS” under search term for this if required.

L-BAL-E184-GB 2105 Index 003 Part.-No.


8/22
Operating Instructions A-G-247NW Operation

5 Operation
5.1 Display and operating elements of the terminal

Hand held terminal type A-G-247NW

1 Switch on terminal
2 Program key and open menu
3 Menu selection, increase value
4 Menu selection, reduce value
5 From each menu (member) directly back to the display for “Speed”
6 Escape = exit menu for settings (user), cancel input
7 - Select type of user
- back to selection of user (exit application)
- Switch off terminal (keep key pressed for a few seconds)
8 "Main menu" = momentarily active menu level ( |>>> | = batteries being charged, |====- | = full)
9 Selection option of the sub-menu (display in menu language English)
10 Key not assigned (soft key, program-dependent function)

Explanation of display (menu User)


1. Numeric display 5 digit
2. Moon-Symbol for set point 2 (only AM-PREMIUM)
3. Current derating active
4. Alarm-Symbol ( member's operating instructions)
5. Brake motor or motor heating active
6. Fire-Symbol for heating operation (only AM-PRE-
MIUM)
7. Temperature management active
8. No connection to Modul (only AM-MODBUS)
9. Quench mode active
10. STOP-Symbol (enable)
11. Bargraph Fanlevel
Display of symbols depending on the 12. Text line 3 figures (display unit, etc.)
type of member and used communica- 13. Text line 16 figures (display text menu.)
tion module.

L-BAL-E184-GB 2105 Index 003 Part.-No.


9/22
Operating Instructions A-G-247NW Programming

6 Programming
6.1 Overview mainmenu

Mainmenu Exit menu with the top left key ◄.


▼▲
AM-MODBUS APP`s P → ▼ ▲→ P ▼ ▲→ P
RS-485
Programming of devices with integrated communication mod-
ule AM-MODBUS (RS-485).
Configuration online
Wireless
Programming of devices with integrated communication mod-
ule AM-MODBUS-W (wireless).
Automatic addressing of the members in the MODBUS net-
Auto Addressing
work.
Load Parameterset Load paramterset from terminal to AM-MODBUS(-W).
Device Check Checking of the members in the network (as of version 9.00).
▼▲
AM-PREMIUM App’s P→ P ▼ ▲→ P
RS-485
Programming of devices with integrated universal control
module AM-PREMIUM (RS-485).
Configuration online
Wireless
Programming of devices with integrated universal control
module AM-PREMIUM-W (wireless).
▼▲
AXG Mode P → ▼ ▲→ P
Operation of ZIEHL-ABEGG devices with RS-485 MODBUS
247 interface without built in Add-on module AM-MODBUS(-W)
or AM-PREMIUM(-W)!
▼▲
USB Filetransfer P
USB Filetransfer Filetransfer terminal ↔ PC via USB
▼▲
USB COMPORT P → ▼ ▲→ P
RS-485 Interface converter USB ↔ RS-485
Wireless Interface converter USB ↔ wireless
▼▲
A-G-247NW Setup P → ▼ ▲→ P
Start Basic settings for terminal

L-BAL-E184-GB 2105 Index 003 Part.-No.


10/22
Operating Instructions A-G-247NW Programming

6.2 AM-MODBUS App's

6.2.1 Configuration Online

Configuration online Open menu with the P key and close it again with the top left key ◄.
Interface Select type of interface with the ▼ + ▲ keys and confirm with the P key.
Programming of devices with integrated communication module AM-
RS-485
MODBUS (RS-485).
Programming of devices with integrated communication module AM-
Wireless
MODBUS-W (wireless).

Establish connection to member

Select device Setting for the device address


The device address is factory set to the highest available MODBUS address:
247
• Confirm the factory set address “247” with the P key for the first
247 connection.
• For members with changed addresses, set these from 001 to 246 with
the ▼ + ▲ keys and confirm with the P key to make the connection.

RF Network Key Radio control key only for wireless communication


• Confirm the factory set radio key “9999” for the first connection.
9999 • For members with a changed radio key, set this with the ▼ + ▲ keys
and confirm with the P key to make the connection.

BASIC-247 Example of correctly set address: 247

☻ Successful connection!

BASIC-246 Example of incorrectly set address: 246


No connection!
Settings are not possible!

? In the display the two symbols for alarm and antenna appear

Cause: wrong address, no connection via wire and/or radio

L-BAL-E184-GB 2105 Index 003 Part.-No.


11/22
Operating Instructions A-G-247NW Programming

6.2.2 Auto Addressing

Auto Addressing Automatic addressing


Open menu with the P key and close it again with the top left key ◄.
Start
Start automatic addressing with the P key.
P
Please Wait
Count: 0 The number of the addressed members is displayed as a result.
Done

For further details see AM-MODBUS(-W) operating instructions.

6.2.3 Load Paramterset


Information
Befopr a parameter set can be loaded into the terminal, this must be saved in the AM-
MODBUS(-W) ( menu group “Start” / “SAVE”).

Load Parameterset Open menu with the P key and close it again with the top left key ◄.

PIN input PIN input. In the download only parameters for the entered authorisation are
considered ( operating manual AM-MODBUS).
• PIN 0010: Opening service menu (Controller Setup, IO Setup, Motor
Setup), for programmed access level <2.
0000 • PIN 1234: Opening user menu (Setting) for programmed access
level <1.
• PIN 3698: Assumption of the communication parameters (Address,
Com Baudrate, Com. Mode).

Interface Select used interface:


For members with integrated communication module AM-MODBUS (RS-
RS-485
485).
For members with integrated communication module AM-MODBUS-W (wire-
Wireless
less).

Select device Select the address of the desired member with the ▼ + ▲ keys and confirm
247 with the P key.

RF Network Key Wireless


Only for communication wireless:
9999
Select radio control key with the ▼ + ▲ keys and confirm with the P key.

Parameterset
Files

L-BAL-E184-GB 2105 Index 003 Part.-No.


12/22
Operating Instructions A-G-247NW Programming

Display as long as no parameter set is saved in the member’s AM-


Empty directory!
MODBUS(-W) yet.
ECBLUEX.CSV
Select desired parameter set with the ▼ + ▲ keys and confirm with the P
TEST01.CSV
key.
TEST02.CSV

Parameterset
File: TEST01.CSV
Press the P key to start download.
Start Download
P
Download OK! Exit menu with the top left key ◄.

6.2.4 Device Check


The networked members can be tested with this function (as of version 9.00).

Device Check Open menu with the P key and close it again with the top left key ◄.

Interface Select used interface:


For members with integrated communication module AM-MODBUS (RS-
RS-485
485).
Wireless For members with integrated communication module AM-MODBUS-W (wire-
less).

Device Count Enter the number of devices (max. 64) with the ▼ + ▲ keys and confirm with
the P key.
006 If the automatic addressing was performed first, the number of detected
devices is taken over.

RF Network Key Wireless


Only for communication wireless:
9999
Select radio control key with the ▼ + ▲ keys and confirm with the P key.

Device Check
Start Start the test procedure with P.
P

L-BAL-E184-GB 2105 Index 003 Part.-No.


13/22
Operating Instructions A-G-247NW Programming

Device Check
1: ECblue 11.05 √
Every device from address 1 to the number “Device Count” is queried
2: ECblue 9.05 √ (product code, version, error status).
3: ECblue 11.05 √
• Devices that reply are displayed with product name and version.
4: ECblue 11.05 !
• The device has an error if an exclamation mark is displayed.
5: ECblue 11.05 √
• Everything is OK if a checkmark is displayed!
6: ECblue 11.05 √
Show Details

Device Check
1: ECblue 11.05 √
2: ECblue 9.05 √
3: ECblue 11.05 √ Every member can be selected and marked with the ▼ + ▲ keys, the exact
4: ECblue 11.05 ! reason for the error is displayed by “Show Details” after pressing the ◄ key.
5: ECblue 11.05 √ OK appears if there is no error!
6: ECblue 11.05 √
Show Details

Device Check
1: Timeout !
2: Timeout !
3: Timeout !
If the devices are not available, “Timeout” appears after 500 ms in this
4: Timeout !
process.
5: Timeout !
6: Timeout !
Show Details

6.3 AM-PEMIUM App's

6.3.1 Configuration Online

Configuration online Open menu with P-key.


Interface Select type of interface with the ▼ + ▲ keys and confirm with the P key.
Programming of devices with integrated universal control module AM-PRE-
RS-485
MIUM (RS-485).
Programming of devices with integrated universal control module AM-PRE-
Wireless
MIUM-W (wireless).

L-BAL-E184-GB 2105 Index 003 Part.-No.


14/22
Operating Instructions A-G-247NW Programming

Establish connection to member

Select device Setting for the device address


The device address is factory set to the highest available MODBUS address:
247
• Confirm the factory set address “247” with the P key for the first
247 connection.
• For members with changed addresses, set these from 001 to 246 with
the ▼ + ▲ keys and confirm with the P key to make the connection.

RF Network Key Radio control key only for wireless communication


• Confirm the factory set radio key “9999” for the first connection.
9999 • For members with a changed radio key, set this with the ▼ + ▲ keys
and confirm with the P key to make the connection.

PREMIUM-247 Example of correctly set address: 247

☻ Successful connection!

PREMIUM-246 Example of incorrectly set address: 246


No connection!
Settings are not possible!
?
Cause: wrong address, no connection via wire and/or radio

6.4 AXG Mode


Operation of ZIEHL-ABEGG devices with RS-485 MODBUS interface without built in
Add-on module AM-MODBUS(-W) or AM-PREMIUM(-W)!
Alternatively to the use of an external terminal type AXG-1A(E).

AXG Mode Open menu with P-key.


Select device
The device address is factory set to the highest available MODBUS address:
247
247 • Confirm the factory set address “247” with the P key for the first
connection.
• Set changed addresses from 001 to 246 with the ▼ + ▲ keys and
confirm with the P key to make the connection.

For further details about the operation , see the operating instructions of the con-
nected device.

L-BAL-E184-GB 2105 Index 003 Part.-No.


15/22
Operating Instructions A-G-247NW Programming

6.5 USB Filetransfer, only AM-MODBUS(-W)


USB Filetransfer Open menu with P-key.
Filetransfer
USB
Filetransfer
Filetransfer terminal ↔ PC via USB.
Connection
Memory: 1018 MB

• The parameter sets saved in the terminal can be accessed by a PC via the USB
interface.
• 5- pole “Mini-B” connection on the terminal (same connection as for the charger).
The necessary connecting cable is not included!
• After activating the function “USB file transfer” with the P key, the “Windows
Explorer” is opened automatically (if not, open Windows Explorer manually).
• Under |Storage media | the |CSV | folder is displayed.
• The |CSV | folder contains the tables with the parameter sets saved in the
terminal.
Example:
– ECBLUEX.CSV
– TEST01.CSV
– TEST02.CSV
• These can be copied to the PC for backup and administration.
• A parameter set which already exists on the PC can be copied back into the
terminal’s |CSV | folder if necessary.
• With the “Load parameter set” function it is possible to transfer these settings to
other devices.

Save the parameter sets in the terminal.


Operating Instructions AM-MODBUS(-W) -> Menu group “Start” -> Menu “SAVE”.

Attention!
This function serves to save parameter sets and transfer them to other members.
Only change values in the CSV file is you have exact knowledge of the function!

L-BAL-E184-GB 2105 Index 003 Part.-No.


16/22
Operating Instructions A-G-247NW Programming
Example: Parameter set transferred from ECblue 001 to ECblue 002

File X Name

ECBLUEX.CSV
TEST01.CSV
TEST02.CSV
TEST03.CSV

USB

3 USB Filetransfer -> P -> USB Filetransfer

Mainmenu X
Mini-B (5 pin) AM-MODBUS APP`s
AM-PREMIUM App’s
AXG Mode
USB Filetransfer
USB COMPORT
A-G-247NW Setup

2 ECblue -> Load Parameterset -> PIN Input-> RS-485 -> Select device: 002
-> Files -> Start Download
Parameterset IXI
Files
ECBLUEX.CSV
TEST01.CSV
TEST02.CSV
TEST03.CSV

1 ECblue -> AM-MODBUS -> 001->Speed -> Start -> P

MODBUS

AM-MODBUS AM-MODBUS AM-MODBUS


Inside Inside Inside

device: 001 device: 002 device: 003


Parameterset: ECBLUEX Parameterset: ECBLUEX Parameterset: …..
01.03.2013
v_appl_a-g-247nw_usb.VSD

1 Name parameter set of ECblue 001 and save in the terminal:


ECblue -> AM-MODBUS -> 001 -> Speed -> Start -> SAVE
2 Load Parameterset to ECblue 002 :
ECblue -> Load Parameterset -> PIN Input -> RS-485 -> Select device -> Files -> Start Down-
load
3 Access via PC to saved parameter sets in the terminal:
USB file transfer -> P -> file transfer

L-BAL-E184-GB 2105 Index 003 Part.-No.


17/22
Operating Instructions A-G-247NW Programming

6.6 USB COMPORT


USB COMPORT Open menu with P-key.
Interface Select type of interface with the ▼ + ▲ keys and confirm with the P key.
RS-485 Interface converter USB ↔ RS-485
Wireless Interface converter USB ↔ wireless
USB COMPORT
USB • Make the connection to the USB interface on the PC.
VIirtual COMPORT • Follow the further instructions on the screen until installation is
Connecting complete.

USB

Mini-B (5 pin)

Mainmenu X
AM-MODBUS APP`s
RS-485 AM-PREMIUM App’s
AXG Mode
USB Filetransfer
USB COMPORT
A-G-247NW Setup
««««««««««»»»»»»»»»»
wireless

01.03.2013
v_a-g-247_comport.VSD

L-BAL-E184-GB 2105 Index 003 Part.-No.


18/22
Operating Instructions A-G-247NW Programming

6.7 A-G-247 Setup


A-G-247NW Setup Open menu with the P key and close it again with the top left key ◄.

A-G-247NW Setup
P↓ ↑
Start
----- PIN 9095
PIN input Restore factory setting = delivery status
▼▲
Language
Menu language by the factory set to English.
Language GB
In this menu different national languages can be se-
lected (D = German, GB = English).
▼▲
1.05 Device name
A-G-247NW Display of device name and software version

▼▲

A-G-247NW Setup
P↓ ↑
Display
Lighting intensity in battery operation
0 Setting range: 0 - 10
Light at Battery 0 = without background lighting
10 = max. lighting intensity
▼▲
Contrast of Display
0 Setting range: -2...+2
Contrast -2 = minimal contrast
+2 = maximal contrast
▼▲

▼▲

L-BAL-E184-GB 2105 Index 003 Part.-No.


19/22
Operating Instructions A-G-247NW Programming

A-G-247NW Setup
P↓ ↑
COMM Setup
19200
Setting range: 4800 / 9600 / 19200 / 38400
RS-485 Baudrate
▼▲
8EI
Setting range: 8E1 / 8N1
RS-485 Mode
▼▲
0
Setting range: 0 - 15
RF channel

L-BAL-E184-GB 2105 Index 003 Part.-No.


20/22
Operating Instructions A-G-247NW Technical data

7 Technical data
Hand held terminal

Type A-G-247NW
Part-No. 380090
Source of energy 5 V DC
Current consumption charge 1200 mA
LC-Display Graphic display 128 x 64 pixels, LED lighting white
Housing Cover ABS, bottom part ABS, seal TPE
Protection rating IP20 according EN 60529
Dimensions(W x H x D) 159.4 x 33.5 x 77.9 mm
Weight 0.42 kg
Permissible ambient temperature 0...40 °C
Permissible rel. humidity 85 % no condensation
Interference emission according EN 61000-6-3 (domestic household applications)*
Interference immunity according 61000-6-2 (industrial applications)*

* Only in connection with the plug power pack supplied by ZIEHL-ABEGG

Plug power supply unit

Type SYS1421-0605-W2E
Part-No. 00161410
Output voltage 5 V DC
Output current 1200 mA
Secondary plug Mini USB - type B
Housing Cover ABS, bottom part ABS, seal TPE
Protection rating IP20 according EN 60529
Dimensions(W x H x D) 64 x 24 x 78 mm
Weight 0.085 kg
Permissible ambient temperature 0...40 °C
Permissible rel. humidity 85 % no condensation

L-BAL-E184-GB 2105 Index 003 Part.-No.


21/22
Operating Instructions A-G-247NW Technical data

7.1 Manufacturer reference


Our products are manufactured in accordance with the relevant international regulations.
If you have any questions concerning the use of our products or plan special uses,
please contact:

ZIEHL-ABEGG SE
Heinz-Ziehl-Straße
74653 Künzelsau
phone: +49 (0) 7940 16-0
[email protected]
http://www.ziehl-abegg.com

7.2 Service information


If you have any technical questions while commissioning or regarding malfunctions,
please contact our technical support for control systems - ventilation technology.
phone: +49 (0) 7940 16-800
Email: [email protected]

Our worldwide contacts are available in our subsidiaries for deliveries outside of Ger-
many, see www.ziehl-abegg.com.

L-BAL-E184-GB 2105 Index 003 Part.-No.


22/22