0% found this document useful (0 votes)
96 views1 page

Chint Serie NXBLE-125

The document describes a residual current operated circuit breaker (RCBO) as follows: 1. It is compliant with IEC60947-2 standards and has CE certification. 2. It provides overload protection, short circuit protection, isolation, and residual current operation. 3. Its technical parameters include a rated current of 63-125A, rated residual operating current of 0.03-0.3A, rated voltage of 240V or 415V, and rated short-circuit breaking capacity of 10000A.

Uploaded by

Ventas MogroMerc
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
96 views1 page

Chint Serie NXBLE-125

The document describes a residual current operated circuit breaker (RCBO) as follows: 1. It is compliant with IEC60947-2 standards and has CE certification. 2. It provides overload protection, short circuit protection, isolation, and residual current operation. 3. Its technical parameters include a rated current of 63-125A, rated residual operating current of 0.03-0.3A, rated voltage of 240V or 415V, and rated short-circuit breaking capacity of 10000A.

Uploaded by

Ventas MogroMerc
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

P-025 Product description Residual current operated circuit breaker (RCBO)

NXBLE-125 Residual current operated circuit


breaker (RCBO)
1. Compliant standards
IEC60947-2

2. Compliant certification
CE

3. Major function
Overload protection, short circuit protection, isolation, residual current operation

4. Technical parameters
Rated current: 63, 80, 100 (1P+N, 2P, 3P, 3P+N, 4P), 125 (1P+N, 2P);
Rated residual operating current: 0.03A, 0.05A, 0.075A, 0.1A, 0.3A;
Rated voltage: 240V ~ (1P+N, 2P), 415V ~ (3P, 3P+N, 4P);
Frequency: 50Hz;
Electromagnetic release type: C, D;
Number of poles: 1P+N, 2P, 3P, 3P+N, 4P;
Mechanical life: 20000 cycles;
Electrical life: 6000 cycles (In≤100A); 4000 cycles (In> 100A);
Rated short-circuit breaking capacity(Icu): 10000A;
Short-circuit breaking capacity(Ics): 7500A;
Rated impulse withstand voltage(Uimp): 4kV.

5. Dimensions and installation sizes

H
65.5±0.37
L
49.5±0.31

tilf out
34.5±0.5

2
45±0.31
108±0.70

1 pull out

1P+N 2P 3P 4P
0 0 0 0
L(mm) 54-0.74 81-0.87 108-1.40 135 -1.60
0 0 0 0
H(mm) 75.5 -1.20 78.5 -1.20 78.5 -1.20 78.5 -1.20