0% found this document useful (0 votes)
260 views

Extinguishing Control Panel UL

The document describes the Fireguard iQ800 series extinguishing control panel. It is a microprocessor-based panel that provides flexible protection for multiple areas. It fully complies with UL-864 and NFPA-72 standards. The panel has advanced features like a 16x2 LCD display, 200 event log, 4 initiating device circuits, 2 releasing agent circuits, and 2 notification appliance circuits. It operates on 120-220V AC power with a 24V DC backup battery supply.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
260 views

Extinguishing Control Panel UL

The document describes the Fireguard iQ800 series extinguishing control panel. It is a microprocessor-based panel that provides flexible protection for multiple areas. It fully complies with UL-864 and NFPA-72 standards. The panel has advanced features like a 16x2 LCD display, 200 event log, 4 initiating device circuits, 2 releasing agent circuits, and 2 notification appliance circuits. It operates on 120-220V AC power with a 24V DC backup battery supply.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

FIREGUARD SAFETY EQUIPMENT CO. LTD.

Tel: 00-44-8450751042 Fax: 00-44-8450751043 Email: [email protected]


UNIT 11 | CHANCEL INDUSTRIAL STATE | NEWHALL STREET | WILLENHALL | WV13 1NX | UNITED KINGDOM

www.fireguard-uk.com

Extinguishing control panel


iQ800 series

Fireguard iQ series microprocessor based UL


listed extinguishing control panels provide a
flexible approach to multiple area
extinguishing protection.

Fireguard iQ series panels fully complies with


UL-864 and NFPA-72.
Approval by Underwriters Lab to the most
rigorous of international standards, provides
peace of mind for both designers and
end-users With gas panels often protecting
high cost, high risk areas.

Fireguard iQ series panels are packed with advanced features as standard to


ensure ease of use and high reliability. It comes with 16x2 dot matrix LCD
display with walk test facility & 200 event log.

Model iQ800 series-W (White cabinet)


Model iQ800 series-R (Red cabinet)

Features:
• Fully complies with UL -864 9th Edition and NFPA-72.
• Rugged CRCA sheet with powder coated finish.
• 4 Class B initiating device circuit (IDC).
• All zones accept smoke detectors and any normally open contact device.
• Any Zone can be configured as Alarm or supervisory Zone.

• 2 Class B Releasing Agent Circuits (RAC).


• 2 Class B Notification Appliance Circuits (NAC).

FIREGUARD GLOBAL LTD.


Tel: 00-44-8450751042 • Fax: 00-44-8459751043
Email: [email protected] • www.fireguard-Uk.com
Unit 11 • Chancel Industrial Estate • Newhall Street
Willenhall • WV13 1NX • United Kingdom FS546607
Extinguishing control panel www.fireguard-Uk.com

• Operates on 120 - 220v 50/60 Hz, AC Mains power supply.


• Standby (battery) backup 24v DC power supply with built in charger.
• 16x2 Dot Matrix LCD Display.
• Error free Fire / Fault status in unambiguous colored LED indication.
• System ON indication.
• Main, Standby status audible and visual indication.
• Battery Low visual warning with audible tone.
• 3 Form C relays one for fire and two programmable relays for Fire / fault /
supervisory / Cross Zone / Gas Released.

• RProgrammable two Input Circuits for Manual release and abort.


• Two modes of operations Auto / Manual.
• Programmable 24v D.C. Outputs.
• Programmable NAC2 as RAC1.
• RS 485 Communication facility (Optional).
• 200 Events Log facility with RTC.
• Walk Test facility.
• Zone Isolation facility.
• All field wiring circuits are Power limited except 120 - 220V AC and Battery.
• All field wiring circuits are supervised.
• AC Low voltage cutoff.
• Programmable RAC’s with count down timer
• Programmable NAC's.
• NAC it is saying releasing agent circuit
• Programmable IDC's.
• Programmable Supervisory Mode.
• Programmable AC loss delay.
• Alarm verification on facility.
• Programmable Trouble reminder facility.

2| FIREGUARD GLOBAL LTD. 00-44-8450751042 00-44-8459751043 [email protected]


Extinguishing control panel www.fireguard-Uk.com

Technical Specification :

Primary Power - CN1 (RE - SMPS - 4A - R1)


120 - 220VAC ± 10%, 50 Hz,
Standby Power
24v D.C (2 Nos of 12v, 12Ah Sealed Lead acid battery).
Operating Condition
Operating Temperature – 0 - 49° C/32 -120° F.
Relative Humidity – 93±2% RH (non -condensing) at 25 ±2° C/77±3° F.
Charging Circuit
Charging Voltage – 28.4V, ±0.2V with Current – 800mA (Max.).
Initiating Device Circuits
All zones are Class B Style B/C operation (Programmable).
Normal Operating Voltage : 120 - 220VAC ± 10%, 50 Hz,
Alarm Current : 15 - 30mA.
Short Circuit Current : 45mA Maximum
Loop resistance : 100 ohms Maximum
End-Of-Line Resistor : 3K9, 1/2watt
Standby Current : 7mA (2mA for Detectors)
Notification Appliance Circuits
Class B Style - Y wiring
Operating Nominal Voltage : 24VDC Special Application
Current for all NACs : 1.2Amps (0.6A per circuit)
Current Li mit: CN5 and CN6 via Thermal Fuse
Line Drop : 1.8V
End-Of-Line Resistor : 3K9, 1/2watt
Releasing Appliance Circuits - CN 13 & 14
Class – B Style - Y wiring
Operating Nominal Voltage: 24VDC – Special Application
Current for all RACs: 0.6A per circuit
Line Drop: 1.8V
End-Of-Line Resistor: 3K9, 1/2watt
D.C. Output Power
Supervised 24VDC regulated. 300mA Max. (for 4 wire smoke detector)
Common Three Form C Relays
Relay Contact Rating : 2Amps @ 30 VDC. 2Amps @ 3OVAC.
Power Factor : 0.6
Dimension of the panel
440 x 350 x120 mm (l x h x d)

00-44-8450751042 00-44-8459751043 [email protected] FIREGUARD GLOBAL LTD. |3