0% found this document useful (0 votes)
23 views

HVAC 2015 Mid 2ndsemester

Heating, ventilation, and air conditioning (HVAC)[1] is the use of various technologies to control the temperature, humidity, and purity of the air in an enclosed space. Its goal is to provide thermal comfort and acceptable indoor air quality. HVAC system design is a subdiscipline of mechanical engineering, based on the principles of thermodynamics, fluid mechanics, and heat transfer. "Refrigeration" is sometimes added to the field's abbreviation as HVAC&R or HVACR, or "ventilation" is dropped,

Uploaded by

farah Al-zgoul
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
23 views

HVAC 2015 Mid 2ndsemester

Heating, ventilation, and air conditioning (HVAC)[1] is the use of various technologies to control the temperature, humidity, and purity of the air in an enclosed space. Its goal is to provide thermal comfort and acceptable indoor air quality. HVAC system design is a subdiscipline of mechanical engineering, based on the principles of thermodynamics, fluid mechanics, and heat transfer. "Refrigeration" is sometimes added to the field's abbreviation as HVAC&R or HVACR, or "ventilation" is dropped,

Uploaded by

farah Al-zgoul
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

The University of Jordan - Faculty of Engineering and Technology

Mechanical Engineering Department


$s
ME 0934445: HVAC - Mid exam: 2nd semester,ZilL4lilOLi
lnstrustor; Dr. Osama Ayadi

The most suitable solution for the year round heating and cooling of
a hotel room is a solit unit.
The outside air design temperature for calculating the heating load
for a given application is selected to be the minimum outdoor
re of the total hours during winter season.
The wind chill temperature expresses the combined effect of outdoor
temperature and wind speed on human comfort.
Underfloor heating system is characterized by its high cost and fast
a
The higher the depth of the wall below grade, the higher its overall
heat transfer coefficient.
(

y
Fan coil units are direct expansion dx systems.

l
m i
lf the return air is treated to the rech the supply conditions without
entering fresh air, then the cooling coil and the cooling load of the
buildins are the same.
F a
h
The latent load due to occupants can be detected by using

c
M e
When the occupant number is large, such as theater, then the CLFocc.

ln the calculation of the heating load, the heat gains due to


occupants, lights, applicances and solar effect are subtracted from
The University of Jordan - Faculty of Engineering and Technology
Mechanical Engineering Department
ME 093rt445: HVAC- Mid exam: 2nd semester,ilIl4filOl:i
lnstructor: Dr. Osama Ayadi

Queslio_n 1. [5 pointsl
Fifty employees at a telecomunictions center are working in an open space,
The space is maintained at 20 "C dry bulb temperature and 50% RH.
The office is open from 8:00 am till 1:00 pm when employees leave for a lunch break.
Calculate the following:
a. Total heat gain rate due to occupants at 10:00 am.
b. Total and latent heating loads due to ventilation if the outside fresh air is
available at 5 "C dry bulb temperature and 60% RH"

Question 2. [4 oointsl A solid wall consists of firm stone of 30 mm thickness, concrete


of 100 mm thickness (p = 2300 kg/m'), polysteren layer of unkown thickness, cement
bricks with air gaps of 70 mm thickness (k= 0.90 Wm.K), cement plaster of Z0 mm
thickness ( k=1.25 Wm.K). if the wall is to satisfythe Jordanian code with an overall
heat transfer coefficient of 0.57 $m^2.K, how much should be the insulation thikness?

Qu$stion 3. [3 pointsl

l y
A Jordanian family of six members with low hot water consumption at 50 "C, assume
that the supply cold water temperature is 15 'C, and the boiler is required to heat the

i
water in two hours, the boiler capacity is?
m
a
QueFtion 4. [7 pointsl
F
c h
Outside air at 38 "C dry bulb temperature and 6O0A relative humidity eneters a cooling
and dehumidfuing device at a volumetric flow rate of 3800 nn3/h. The air leaves the

M e
device at90% relative humidity. The inside design condition is 26 "C and 45o/o relative
humidity. The sensible heat ratio is 0.75 (assume 100%fresh air)
a. Sketch the process on the psychrometric chart, and calculate the following
b. Apparatus dew point.
c. Dry bulb and wet bulb temperatures of the supply air.
d. Cooling capacity of the air conditioner.
e. Amount of moisture removed.
f. Mass of chilled water for the cooling coil, if the supply and return temperatures
from the chiller are 7oC / I'Z'C respectiveley
- ..,.. *m-t\ q FZ g-*
u,,r+r 4^jr
i
+rrjt rt
,KJl C>JF--rtlr
i.:t U

---*nlt

l y
:5eo m lls i
= b*5o
o,t1 lf
L
F a
2o,n
= lrF
c h
0.5
o\ M e (i.

t.- = ilo.A \h Fs{ rX,z

-\ -
\

: o,r3 tt
tn- K

Gncfil f tqS 1, f ,"

0.\? < o',06 + J*. * ".; *a t o.ot + o'oz


\. ?5
: o,0 qLT $ ly
i m
F a
c h
M e

-Y-
fttt 2 to7.
=u-75 \* = q6Y-
,, rfil[: \,e84
: o,OOl7
ol
3 0, oL6i
V= 6.Et r'Ste
,14 { fi /l

l y
m i
F a
c h
M e
,ln I
I
-neA :ft ho -h
I'l't{ [o"f - ,q71

f{tt - (^J
= o, oJo -91 t't u