Series Electromagnetic Flowmeter
Integral Type:
Remote Type:
KFL® KFL-DC Series Electromagnetic Flowmeter
Specifications
-2-
KFL® KFL-DC Series Electromagnetic Flowmeter
Flow Ranges and Meter Sizes
Min. Flow Range Max. Flow Range
Meter Size
Flow Velocity Flow Velocity
-3-
KFL® KFL-DC Series Electromagnetic Flowmeter
Flowrate Nomograph
Fig. 3: Flowrate Nomograph DN1 to DN 100 (3/8” to 4”) Fig. 4: Flowrate Nomograph DN 125 to 1000 (5” to 40”)
Flowrate Nomographs Example:
The v olume f lowrate i s a f unction of t he flow v elocity and Flowrate = 7 m³/h [30.82 gpm] (Maximum value = range
the flowme-ter size. The Flowrate Nomographs, Fig. 3: and end v alue). S uitable ar e flowmeter s izes D N 20 t o D N
Fig. 4: i ndicate t he flowrate r ange f or a specific flowmeter 65 [3/4” to 2-/12”] for a flow velocity between 0.5 and 10
size and w hich f lowmeter s izes a re s uitable for a specific m/s [1.64 and 32.81 ft/s].
flowrate.
-4-
KFL® KFL-DC Series Electromagnetic Flowmeter
Model and Sufix Code
Suffix Code Description
KFL-DC - - - - - Model format
DN -XXX Nominal size DN2-2200 mm
L 316L
V Titanium
Electrodes T Tantalum
material H Hastelloy
M Monel
P Platinum-Iridium
C Chloroprene Rubber (DN65-2200mm)
F FEP (DN10-500mm)
Lining material
T PTFE (DN50-300mm)
9 Customization
F Carbon steel flange
S 304 Stainless steel Flange
Process connection T Thread connection (DN10-100)
W Wafer connection (DN10-DN200)
C Tri-clamp connection (DN10-100)
-G1.6 DIN PN. 0.6, 1.0, 1.6, 2.0, 2.5, 4.0, 16, 25, 35, 42MPa
Working pressure -A150 ANSI CL150, CL300, CL600, CL900, CL1500, CL2500
-J10 JIS 10K, 20K, 30K
C Carbon steel
A Cast-aluminum (DN10-300)
Flow sensor housing material
S 304 Stainless steel with painting (DN10-350)
P 304 Stainless steel without painting (DN10-300mm)
L <60℃ (Short time can up to 80℃)
T <120℃(Integral type with cooling fin)
Liquid temperature S <120℃(remote type)
E <180℃(Integral type with cooling fin)
H <180℃(Only remote type)
A IP65
Flow sensor protection Class B IP68(Only remote type or Magnetic water meter type)
C IP67(Now unavailable)
-M Integral type
Construction
-D Remote type
A 100VAC-240VAC
Power supply B 20-36VDC
C Lithium battery (Pulse output only for calibration)
L Standard type (MT100, MT101)
X Explosion type (MT120)
N Process control type(MT130)
B Batch control type (MT140)
Transmitter type
E Battery supply type (MT150,MT151)
H Magnetic water meter type (MT152, battery supply, IP68)
S Slurry type (MT160, MT161)
9 Special type
Output signal 1 -C C:4-20mA output;D:0-10mA output;N: No current output
P:Pulse output;F:Frequency output;J: Battery supply pulse output;
Output signal 2 P
N: No pulse output
N: No communication; S: RS485 (MODBUS); R: RS232 (MODBUS)
Communication N B: RS485 (MODBUS)-Battery supply type;
F: PROFIBUS; H: HART; G: GPRS; A: CDMA
0: No cable (Integral type)
Cables length -0 1: 5m of signal and exciting current cable (Remote type default)
2: 10m; 3: 15m; 4: 20m; 5: 25m; 6: 50m; 7: 80m; 8: 100m