TRC Type
TRC Type
■ Feature
• IP66
CE@ A 0259672
■ Ordering information
• DC 3-Wire • DC 2-Wire
NPN NO TRC12-2DN
NO TRC12-2DO
QI II DI 2mm
NPN NC
PNP NO
TRC12-2DN2
TRC12-2DP
@::ID 2mm
NC TRC12-2DC
M12
®en
PNP NC TRC12-2DP2 NO TRC12-4DO
M12 4mm
NPN NO TRC12-4DN NC TRC12-4DC
o::fflb:n
NPN NC TRC12-4DN2
OIQo
4mm NO TRC18-5DO
5mm
PNP NO TRC12-4DP
NC TRC18-5DC
mlOD
PNP NC TRC12-4DP2 M18
NO TRC18-8DO
NPN NO TRC18-5DN 8mm
NPN NC TRC18-5DN2 NC TRC18-8DC
5mm
OD
� PNP NO TRC18-5DP
10mm
NO TRC30-10DO
PNP NC TRC18-5DP2
M18 NC TRC30-10DC
TRC18-8DN M30
[p
NPN NO
NO TRC30-15DO
NPN NC TRC18-8DN2 15mm
8mm
� PNP NO TRC18-8DP NC TRC30-15DC
PNP NC TRC18-8DP2
• AC 2-Wire
NPN NO TRC30-10DN
[p
Appearance Detecting Output Model
NPN NC TRC30-10DN2 distance
10mm
PNP NO TRC30-10DP
w�I I
J7l/n NO TRC12-2AO
M30
PNP NC TRC30-10DP2
""
I II 2mm
NC TRC12-2AC
NPN NO TRC30-15DN
M12
op c®r::n
NPN NC TRC30-15DN2 NO TRC12-4AO
15mm 4mm
PNP NO TRC30-15DP NC TRC12-4AC
�- Ill II
NO TRC18-5AO
• Connector
11111 5mm
NC TRC18-5AC
M18
NO TRC18-8AO
Appearance Table Model
[llpt111 8mm
NC TRC18-8AC
OD
2 -wire Cl2-12 NO TRC30-10AO
M12
"l"model �� 3 -wire Cl3-12 10mm
4 -wire Cl4-12 NC TRC30-10AC
b=-
M30
ap
2 -wire CL2-12 NO TRC30-15AO
M12
3 -wire CL3-12 15mm
"L"model
4 -wire CL4-12 NC TRC30-15AC
6
■ Specification
Oetecting distance
2mm±10% 4mm±10% 5mm±10% 8mm±10% 10mm±10% 15mm±10%
Setting distance
Oto 1.4mm Oto 2.8mm Oto 3.5mm Oto 5.6mm Oto 7mm Oto 10.5mm
Standard Oetecting
Iron 12x12x1mm Iron 18x18x1mm Iron 30x30x1mm
Hysteresis
Max.10% of detecting distance
AC 20HZ
Protection circuit
Reverse polarity protection , Surge absorber;, Short circuit protection : M12 M18 M30 DC3-wire type
lndicator
Power supply indicator : Green LED, Operating indicator : Red LED
lnsulation resistance
Min.50MQ ( 500VDC)
Oielectric strength
1500VAC 50/60HZ for 1 minute
Vibration
1 mm amplitude al frequency of 10 to55HZ in each of X, Y, Z directions for 2 hours
Shock
500m/s' (50G) X, Y, Z directions for 3times
Operating temperature
-25 to + 70"C (non-freezing condition )
Ambiant humidity
35 to 95% RH
Protection
IP66 (IEC Specification)
Material
Case:brass,Detecting surface:ABS
7
■ Dimensions (unit:mm)
TRC12-2D □ TRC12-4D □
60
43
•I
� 1 0
1 · 1
���
TRC12-2A □ TRC12-4A □
67
1 50
1 1
Œll . ��
•11•36
Il D
TRC18-5D □ 61
TRC18-8D □ 61
a�
!=======;' =
dl., 4
iji [IJ
�
TRC18-5A □ TRC18-8A □
TRC30-10D □ 63 TRC30-15D □ 63
1·
!iJ
�42 50
1
40
,-------r,==lJJtllll=====il
4.2 �
TRC30-10A
�42
□
1--· � 60_________
- J,_____..• 1 1 TRC30-15A
�42
□
10.
1. 1·
50 ·IJ
:1
ffl
3 3
EEl=.
73 73
�
�
Connector CID-12
----ll---------Dll-+---=-------tHl-----
40
•1 1•
., \ .,,,; ;""
1a
Connector CLD-12
42
- :1o�
2000
\M30x1.5
"'
"' r:;; 7f'Ti:rci====;;:::±t:;;;;;::-7 C\J
" C\J
-e- �W_j._RJJJ�::::':::::Ç':::______j -a-
-e-
'l"model
8
■ Control output diagram
• DC 3-wire
Detecting NO NC Detecting NO NC
_Q_ _Q_ _Q__Q_
Presence 1l Presence 1f
target [ target [
Nothing ;le Nothing ;le
��'io/.1 �;Jll/*-1
Load
Output
[
0peratioo �it
Return
_0__ i7 n
�� L.l___LJ
Load
Output
[
0peration ii}Jfla
Return ·�� nnn
O_O_O__ [� _O__O_[J
Voltage H Voltage
[
�tll Egff L �tll<gff
ON ov 1:lif-:tr ON
[
OFF _O__O_[J (LED)
[
OFF _O__O__O
• AC 2-wire
Detecting NO NC Detecting NO NC
+V
target
�;Jll/*-1
[
Presenceif
Nothing ;le
_Q__Q_
target
�;Jll/*-1
[
Presence 1f
Nothing X
_Q_ _Q_
':i
Load [
Operaton
�
Return �
ft
_0__f7 ,
7
L.l___LJ
,3
'<ij
Load [
Operatioo iiJJit
Return�
_Q_ 0_0
::;;
0 OV
11lir-:tr
(LED)
[
ON
OFF _O__O__O Blue
0V
1:lir-:tr
(LED)
[
ON
OFF _O__O__O
■ Wiring diagram
• DC 3-wire e DC 2-wire
NPN PNP
■ Proper usage
• Load connections
Brown
narnCJ]
< DC 2-wire type &AC 2-wire type>
< DC 2-§ill'i & AC 2-§ill'i >
< DC 2-wire type>
< DC 2-!:J.ll'i >
24VDC
_____,____, Load e----- Il may cause return failure of load by residual voltage. If the load current is under 5mA. please
make sure the residual voltage is less than the return voltage of the load by connecting
AC
Bleeder resistor ~ POWER a bleeder resistor in parallel with the load as shown in the diagram.
füm<g!ll(R)