Condominium
Condominium
ARCHITECTURE
~ UP-FC1-BSAR4-02 ~
~ 07:30 AM – 1:30 PM (Thursday) ~
RSW No: 1
PRESCILO N. PALOR IV
STUDENT
KEY TAKEAWAYS
A condominium, or condo, is an individually owned unit in a complex or
building of units.
A condo owner owns the air space inside their condo, sharing an
ownership interest in the community property, such as the floor, walls,
sidewalks, stairwells, and exterior areas.
A general requirement of a condo owner is monthly payments to a
condominium association that is in charge of property upkeep.
The main difference between an apartment and a condo is ownership; an
apartment is generally rented and a condo is owned.
If major repairs are needed, condo owners may be assessed a special fee,
in addition to their regular fees, to cover such costs.
SPECIAL CONSIDERATIONS
Condominium developers differ in the ways they provide parking
spaces and garages to unit owners. In some developments, these spaces are
reserved as limited common areas, and the condo association maintains
ownership but gives exclusive rights for the unit owner to use the space or
garage.
In other developments, the unit owner buys the garage or parking
space and has ownership. However, the covenants, conditions, and
restrictions may still limit the owner's ability to sell or rent the space
independent of the unit itself.
PROS
Condos are typically cheaper than other residences.
Condos often come with shared amenities, such as security
services, maintenance, and common areas.
CONS
Owners will have to pay additional condo fees to pay for
maintenance.
Condo owners may have less privacy due to shared walls and
spaces.
Condominium associations may place additional restrictions on
condo residents.
PD 957
REVISED RULES AND REGULATIONS IMPLEMENTING THE SUBDIVISION AND
CONDOMINIUM BUYER'S PROTECTIVE DECREE (PD 957) AND OTHER
RELATED LAWS
Pursuant to Article IV Section 5 c) of Executive Order No. 648 the following
rules are hereby promulgated by the Housing and Land Use Regulatory Board
(HLURB) to implement Presidential Decree Nos. 957, 1216, 1344 and other related
laws applicable to open market and medium cost subdivision and condominium
projects.
RULE I
MINIMUM DESIGN STANDARDS
A. Site Criteria
1. Location
Conformity with Zoning Ordinance/Comprehensive Land Use Plan
Subdivision projects shall be located in residential zones or other areas
appropriate for residential uses. If there is no Zoning Ordinance or approved
Comprehensive Land Use Plan, the dominant land use principle and site
suitability factors cited herein shall be used in determining suitability of a
project.
Subdivision projects supportive of other major urban activities (e.g.
housing for industrial workers) may be allowed in area zoned for the said
urban activities.
2. Physical Suitability
Subdivision projects shall be located within suitable sites for housing
and outside hazard prone areas and protection areas as provided for by
pertinent laws. Critical areas (e.g. areas subject to flooding, landslides and
those with unstable soil) must be avoided.
The site shall be stable enough to accommodate foundation load
without excessive earthmoving, grading or cutting and filling.
3. Accessibility
The site must be served by a road that is readily accessible to public
transportation lines. Said access road shall conform with the standards set
herein to accommodate expected demand caused by the development of the
area. In no case shall a subdivision project be approved without the necessary
access road/right-of-way. Said access road right-of-way may be constructed
either by the developer or the local government unit.
B. Planning Considerations
1. Area Planning
Planning and designing of subdivision projects shall take into account the
following:
a. safety and general welfare of the future occupants:
b. adequate, safe, efficient and integrative road circulation system
servicing every lot therein;
c. judicious allocation of land uses for diversity and amenity;
d. preservation of site
e. proper siting or orientation of lots;
f. harmony with existing and proposed development in the vicinity;
g. Application of workable design principles or parameters for a well
planned and self-sustaining environment.
When a developer or planner submits a Planned Unit Development
(PUD) type of project, the layout shall likewise conform to the standards for
residential/condominium projects.
A. Open spaces
Open spaces shall conform to the provisions of P.D. 1216 and its
implementing rules and shall include the following:
a. 1 Streets - adequate and safe means of vehicular and pedestrian circulation
and easements for utilities and planting strips, shall be provided.
a. 2 Walks - paved walks shall be provided to the living units from streets,
parking spaces and from living units to play areas
a. 3 Parks and playground - suitable recreational area(s) shall be allocated
within the subdivision. Where applicable, a hierarchy of such recreational
areas may be provided for, such that, a strategically located main park area is
supplemented or complemented by one or more smaller pocket(s) or areas for
recreational use. These areas must be accessible to living units and free from
any form of hazard or risk_ Said parks and playgrounds shall be cleared and
free from any debris. Parks and playgrounds as much as possible shall be at
street level.
C. Density
Density of subdivision projects shall conform with the residential densities set
forth in the zoning ordinance of the city/municipality where project is located.
Where there is a mixture of housing types within the subdivision (such as
single-detached, row house, town houses, etc.), density shall include the total
number of dwelling units in multi-storey structure plus the total number of lots
intended for single and semi-detached houses.
2. Site Preservation
A. Slope
The finished grade shall have a desired slope to allow rain water to be
channeled into street drains. Where cut and fill is necessary, an appropriate
grade shall be attained to prevent any depression in the area.
Grading and ditching shall be executed in a manner that will prevent erosion
or flooding of adjoining properties.
C. Ground Cover
Grass, shrubs, plants and other landscaping materials used for ground cover
shall be of a variety appropriate for its intended use and location. They shall
be planted so as to allow well-tended cover of the area.
3. Easements
Subdivision projects shall observe and conform to the following provisions on
easements as may be required by:
a) Chapter IV, Section 51 of The Water Code, on water bodies;
b) National Power Corporation (NPC), on transmission lines;
c) PHIVOLCS per Resolution No. 515, Series of 1992, on identified fault
traces;
d) Other public utility companies and other entities' right-of-way;
e) National/local government units for projects abutting national roads
(primary roads) where adequate easement shall be provided for, including
loading and unloading areas;
f) Other related laws.
4. Circulation
Depending on the classification of roads adjacent to the subdivision and the
size of the project site, road network should result into a hierarchy of functions
and should define and serve the subdivision as one integrated unit.
a. Roads complemented with pathwalks within the subdivision must be so
aligned to facilitate movement and to link the subdivision to the nearest
major transportation route and/or adjacent property.
b. Whenever there are existing roads within the project site which shall be
made part of the subdivision plan, these shall be improved in accordance
with the standards set forth herein.
c. Streets should conform to the contours of the land as far as practicable
d. Where a proposed project adjoins a developed property, roads within the
said project shall be connected/integrated/aligned with existing ones.
e. Where a proposed project adjoins undeveloped property, a provision for
future connection shall be mandatory.
f. As far as practicable, streets shall be laid out at right angles to minimize
critical intersections such as blind corners, skew junction, etc.
g. Roads shall conform to sound engineering practices.
C. Design Parameters
1. Land Allocation
For open market and medium cost subdivision projects with an area of one (1)
hectare or more, the percentage (%) allocation of land shall be as follows:
a. saleable area — maximum of 70% of the gross area
b. non-saleable area — minimum of 30% of the gross area
Table 2. Facilities According to the Number of Saleable Lots/ Dwelling Units for
Subdivision Projects I hectare and Above
* Mandatory non-saleable
** Optional saleable but when provided in the plan the same shall be annotated in
the title
Above 15- 30 15 8 12
10
Above 30 15 10 15
ROW Carriageway ROWCarriageway
Motor Court
Alley 6 5 6 5
2 2 2 2
b) Interior Subdivision project must secure right-of-way to the nearest public road
and the right-of-way shall be designated as interconnecting road with a
minimum width of 10 meters. This fact shall be annotated on the title of said
road lot and must be donated and deemed turned over to the LGU upon
completion of the said interconnecting road. (See Figure 1)
Figure 1. Interconnecting Road
d) Subdivision projects shall have provision for future expansion where applicable, by
designating the major roads, as prescribed in Sec. 1.C.b.3.2 as the interconnecting
road right-of-way for both open market and medium cost housing projects.
2. Lot requirements
a. Lot Layout:
The following shall be considered when plotting the subdivision project:
A.1 Preservation of site assets and proper siting orientation of lots;
blending with existing and proposed development in the vicinity; and
A.2 Application of workable design principles/parameters for a well
planned environment.
To accommodate a wider range of clientele (in terms of income level and
lifestyle), and to provide diversity in housing design in a subdivision project,
the owner/developer is encouraged to allocate areas for various housing types
such as single-detached, duplex/single attached and row houses.
c. Lot Design
C.1 Saleable lots shall be designed such that they are not bisected
by political boundaries, water courses, drainage ways and utility lines.
C.2 A lot shall be served by an independent access road.
C.2 Whenever possible, lot frontage elevation shall be at street level.
C.3 Lot lines shall preferably be made perpendicular to street lines.
C.4 Deep lots and irregularly shaped lots shall be avoided.
C.5 Lots shall be planned with adequate width for side yards.
C.6 Lots shall be protected against risks.
C.7 Lots shall not be laid out if potential risks exist e.g. erosion,
slides, flooding, fault lines, etc.
d. Lot Frontage
The minimum lot frontages for various types of housing under open market
and medium cost housing projects shall be as follows:
Table 7. Minimum Lot Frontage
TYPES OF HOUSING/LOT FRONTAGE (m.)
1. Single Detached
a. Corner Lot 12
b. Regular Lot 10
c. Irregular Lot 6
d. Interior Lot 3
2. Duplex/Single Attached 8
3. Rowhouse 4
The number of rowhouses shall not exceed 20 units per block/cluster but in no
case shall this be beyond 100 meters in length.
3. Length of Block
Maximum length of block shall be 400 meters, however, blocks exceeding 250
meters shall be provided with an alley approximately at mid-length.
4. Shelter Component
a) a Minimum floor area for open market housing shall be 42 square meters and
30 square meters for medium cost housing.
b) Minimum level of completion - complete house for all types of dwelling units
based on the submitted specifications.
Provision of firewall shall be in conformity with the Fire Code of the Philippines
and mandatory for duplexes/single attached units and every unit for
rowhouses (refer to Fig. 5).
Figure 5. Firewall Requirement for Rowhouse
5. Yard/Setback
The minimum setback of dwelling units both for open market and medium cost
housing projects shall conform to the National Building Code of the
Philippines.
6. Water Supply System
a) Specific Rules:
The subdivision water supply shall be mandatory or obligatorily
connected to an appropriate public water system or community system
provided that the water supply is enough to meet the total daily
requirements of the anticipated population.
When neither a public water system, nor an acceptable community
system is available, a centralized water supply system shall be
accepted, provided that:
a.1 The technical consultant of the developer shall determine the
location and discharge capacity of the water source(s) within the
subdivision;
a.2 The permit to drill well(s) or tap water lines from the appropriate
government agencies shall be obtained;
a.3 The water source shall be sufficient to meet the daily water
requirements of every household in the subdivision;
a.4 No hazards shall exist in the immediate vicinity of the water source
that might reduce or pollute the supply;
a.5 Water distribution shall be assured.
Accordingly, every water service entrance or connection shall be
provided with a pressure-compensating, self-regulating, constant
flow valve or fitting to ensure equitable distribution of water, water
and power conservation, and longterm savings on operational costs
of the water system.
a.6 Each subdivision shall have at least an operational deep well and
pump sets with sufficient capacity to provide Average Daily Demand
(ADD) to all homeowners.
b) Water Requirement - Every dwelling unit shall be served by an individual
supply of water sufficient to meet the total hourly domestic needs of every
household for any 8 hour period.
c) The Average Daily Demand (ADD) for both open market and medium cost
housing projects is 150 liters per capita per day (LCPD) household
connection. (Per Board Resolution No. 506, series of 1992)
d) Fire Protection Demand - Provision for fire protection shall comply with the
requirements of the National Fire Protection Code.
e) Water Tank Capacity - 20% ADD plus fire reserve.
f) Pipes - Pipes shall conform to the standards required by Metropolitan
Waterworks and Sewerage System (MWSS) and/or Local Water Utilities
Administration (LWUA).
7. Electrical power supply
Mandatory individual household connection to primary and/or alternate
sources of power.
Installation practices, materials and fixtures used shall be in accordance with
the provisions of the Philippine Electrical Code and/or local utility company.
Provision of street lighting per pole is mandatory at 50-meter distance and
every other pole if distance is less than 50 meters.
Electrical bills for streetlights shall be proportionately shouldered by the users
thereof prior to issuance of Certificate of Completion (COG) and turn-over of
open space to LGU.
do - do -
do – do –
do – do –
a. Minimum Water 150 liters per capita per day for household connection
Supply Requirement
b. Fire Protection Provision for fire protection shall comply with the
Demand requirements of the Fire Code of the Philippines.
a. Minimum Floor
Area
42 sqm 30 sqm
a.1 Single Detached
42 sqm 30 sqm
a.2 Duplex
42 sqm 30 sqm
a.3 Row house
A. Site Criteria
Conformity to Comprehensive Land Use Plan/Zoning Ordinance/National
Building Code
1. Residential condominium projects shall preferably be located in areas zoned as
or appropriate for residential uses.
B. Planning Consideration
1. Area Planning
a. Supplementary and supportive activities to residential use shall be allowed
provided that the privacy, order, health and safety of the residents are not
jeopardized nor threatened and that the land use plan and/or zoning
ordinance of the locality can accommodate such mixture of land uses.
b. Open spaces shall be provided within the project site pursuant to the
National Building Code of the Philippines and its Implementing Rules and
Regulations. These shall include courts, yards, setbacks, light wells,
uncovered driveways, access roads, parking spaces, buffer strips, parks
and playgrounds. Except as may hereafter be otherwise provided these
spaces shall be open from the ground to the sky. The open space shall
also be allocated for basic utilities and community facilities or common
areas.
c. Easements for utilities, such as drainage system, water supply, power
lines and communication lines, shall be integrated with land circulation
system.
d. Building orientation on lot shall take into account proper ventilation,
sunlight and land characteristics.
e. No development shall be allowed within the 5-meter mandatory easement
on both sides of the Marikina Valley Fault Trace and such other fault
traces as may be identified by PHIVOLCS. (Approved per Board Res. No.
515, Series of 1992)
2. Site Preservation/Alteration
a. Slope
The finished grade shall have a desired slope to allow rainwater to be
channeled into street drains. Where cut and fill is necessary an
appropriate grade shall be attained to prevent any depression in the area.
Grading and ditching shall be executed in a manner that will prevent
erosion or flooding of adjoining properties.
b. Preservation of Site Assets
Suitable trees with a caliper diameter of 200 millimeters or more, as well
as shrubs and desirable ground cover shall be preserved in accordance
with the implementing rules and regulations of DENR. Where good quality
top soil exists in the site, it shall be banked and shall be preserved for
finishing grades of yards, playgrounds, parks and garden area.
c. Ground Cover
Grass, shrubs, plants and other landscaping materials used for ground
cover shall be of variety appropriate for its intended use and location.
They shall be so planted as to allow complete and permanent cover of the
area.
C. Design parameters
1. Space location
Space allocations shall provide areas for living, dining, kitchen, sleeping, toilet
and bath, laundry/ drying area and storage - the minimum sizes of which shall be
in accordance with the requirements of the National Building Code of the
Philippines and its Implementing Rules and Regulations/referral codes.
a. Parks/Playground and/or Other Recreational Areas
a.6 Other facilities (optional) such as tennis courts, swimming pool, etc. may
be integrated with the park/playground.
c. Access Roads
Roads shall serve every building, parking space, park/playground and service
points (e.g. garbage collection points). Minimum roads or right-of-way shall be
8 meters, 6 meters thereof shall be the carriageway and the remaining 2
meters shall be developed as sidewalk/planting strip.
Path walks shall be provided for pedestrian circulation with a minimum width
of 1.2 meters.
Construction of roads, sidewalk and path walks, shall be in accordance with
the standards of residential subdivision. Space for turnaround at dead end
shall be provided.
Direct vehicular access to the property shall be provided by public street or
alley.
An independent means of access shall be provided to each dwelling, or group
of dwellings in a single plot. Without trespassing adjoining properties. Utilities
and service facilities- must be independent for each dwelling unit.
An independent means of access to each living unit shall be provided without
passing through any yard of a living unit or any other yard.
d.2 Water supply, power, sewerage and drainage utilities shall conform to the
requirements of a subdivision.
a.2 The same shall be provided with common basic facilities such as
laundry/drying area and support amenities such as visitor's lounge and
dining area.
a.3 Said facilities/support amenities including all other measures that will
ensure compliance with the intended use of the unit shall be explicitly
indicated in the master deed/ contract to sell.
1) The location is unique and different from the adjacent locality, and because of its
uniqueness, the owners cannot obtain a reasonable return on the residential
subdivision/condominium projects;
4) The variance will not alter the essential character of the location where the
residential subdivision for which the variance is sought, is located, and will not
substantially or permanently affect the use of the other residential
subdivision/condominium in the same locality; particularly those within a 1
kilometer radius thereof;
5) The variance will not give rise to unauthorized reclassification of the approved
residential subdivision/condominium plan (i.e. whether partial or full alteration of
the plan), and will not adversely affect the public health, safety or general welfare
of the community. (Per Commission Proper Resolution No. R-53, S. 1982)
SAMPLE OF CONDOMINIUM PRPOJECTS
VISTA BRENTHILL BAGUIO
REFERENCES:
https://hudcc.gov.ph/sites/default/files/styles/large/public/document/IRR%20PD
%20957.pdf
https://www.investopedia.com/terms/c/condominium.asp