RollNo
Erarnination:' Nov.-Dec., 2019 Prograntme: B.Tech. i Semester
Steel Structures
\: aEPC-15 Maximurn Marks 50
:. ;-:c.::ons to be Atternpted 5 ....... Tirne allorved 3 I-loLrrs
- ,.,esiions 5 .......,.......... Total No. of Pages used 2.
:'::ili .ilrer\vise. the Svmbols have their usual meanings in context ivith the Sub.ject.
- .,.::i--.i) and state additional data required, if any.
r. A steel plate is 30cm wide and l0 mm thick. If the diameterof the bolt hole is 20 rnm, the net
section area of the plate is
vi. The design tensile strengtlr of a plate dueto rupture of critical section is given by ...
vii.'l'he slenderness ratio of lacing flats is lirnited to ....
viii.'fhe optimum depth o1'plate girder is given by ....
ix. The nominal bealing strength of the bolt is given by 2.5kr,.dtf,,, where k5 depends Llpon .....
x.
' ancl For the coluuru of unsupportecl lengtlr L, with one end restrained in translation and rotatiorr
the other end restrained in rotation bLrt fi"ee to translate. The elfective length will be
given by (lxl0)
1 a. Briefly explain the varioLrs types of lhilLrre of Bolts and Plates. 3
b. Design a double cover plate bLrtt.joint using M24 bolts of 5.6 grade to conr'lect two flats of
size 350rnm xl6 mtl for maximurn efficiency. Assume that orre shear plane intercepts the
threacis of tlre bolts.-l'lre yielcl ancl ultimate teusile strength of'thc llats arc 250 MPa ancl 410
M Pa. respectivu'ly. 1
J, Design a single angle to carry a tension of l00kN.'fhe end connection is to be done using M20
bolts of grade 4.6. The yield and ultimate strenglh of the steel are 250 MPa and 4 I 0MPa. I 0
OR
Design a connection to connect a 12 mrn thick bracket with the flange of column ISH8200 as
shown in Fig.1, usit"tg M20 bolts of grade 4.6to carry a factored vertical load of 200kN acting at
300 mm fionr the face of column.'lhe grade of steel is t1250.
KN
300mrn
t0
ft
4. a. Design a built-Lrp column consisting of two channels placed back to back. The l0 m long
column carry factored axial load of l080kN. The column is restrained in position but not itt
direction at both tlie ends. Provide single lacing system with bolted connection, assume steel
grade Fe41 0 and bolts of grade 4.6. 8
b. Design a slab base for a column [email protected]/m subjected to an factored axial load of
l500kN. The load is transferred to the base plate by direct bearing of column flanges. The
base rest or.t concrete pedestal of grade M20. 2
5. a. Design the section of a plate girder 30m in span to carr1,' a uniform load oi 35kN/m
throughout the span, exclusive of self rveigllt. Design the girder using thirr web and end