FLUID METERING

Lambda Square –
Decades of Fluid Metering Experience A Complete Range of Products

Lambda Square provides complete flow measurement ORIPAC - Flow Metering System
systems for gas, liquid and steam flow measurement. Orifice Plates
Secondary instrumenta on is available including
Venturi Tubes
indica ng gauges, manifolds, transmi ers, recorders, and
totalizers with a complete line of op ons. Orifice Flanges
Meter Tubes
ASME Flow Nozzles
Manifolds
Straightening Vanes
Elbow Flow Meters
Seal Pots/Condensate Chambers
Holding Blocks
Restriction Unions
Sanitary Plates
Single Chamber Fittings
Dual Chamber Fittings

One example of our many products – standard and custom Orifice Plates

Toll-Free: 1-800-587-5423 · Tel: (631) 587-1000 · Fax: (631) 587-1011


LAMBDA SQUARE, INC. 71 Deer Park Avenue · Babylon, NY 11702-2801 USA
www.LambdaSquare.com · email: [email protected]
© Copyright Lambda Square, Inc. All rights reserved.
ORIPAC FLOW MEASURING SYSTEM
About the ORIPAC FLOW MEASURING SYSTEM
The ORIPAC Series is a complete orifice plate flow metering package
incorporating an orifice plate with a unique holder or carrier ring ORIPAC MODEL 5300
containing metering taps and integral gaskets. Unitized Stainless Steel For Water, Air, Steam, Corrosive
Unlike a standard orifice plate, the ORIPAC is a true primary element Construction Fluids, High-Pressure & High-
including the various components for differential pressure Temperature Fluids
measurement. It was designed for use wherever there is an application
for a conventional flow orifice plate. It can also be used in place of other
primary differential producers for efficiency and cost effectiveness. ORIPAC MODEL 4150
Standard size units available from stock and Fiberglass Ring with For Water, Air, & Gases
customized units are available to meet specific Stainless Steel Plate
field requirements including flange rating, pipe
schedule and differential pressure. Installation is
accomplished simply by slipping the self-
ORIPAC MODEL 4150-P
centering ORIPAC between standard 150#
flanges (orifice flanges are not required). All PVC or CPVC For Low Pressure Gases
The ORIPAC is available for most line sizes and Construction
meets or exceeds AMSE, AGA and ISO standards.
ORIPAC MODEL 4150-T
All Teflon (PTFE) For Corrosive Gases & Liquids
Construction
ORIPAC Installation Instructions
General: Many of the installation problems associated with standard orifice
plates have been eliminated by the use of the ORIPAC. Simply follow these (side view)
instructions for an accurate and reliable meter.
Pipe Requirements: Upstream and downstream pipe requirements are
contingent upon two factors: (a) Beta Ratio:-ratio of the orifice bore "b" divided
by the inlet bore (pipe l.D.) (b) The type of fitting or disturbance upstream of the
ORIPAC. For most applications, 10 pipe dia. upstream & 5 dia. downstream are
sufficient. (5 pipe dia. up and 2 dia. down are acceptable for non-critical
application.) Refer to additional piping requirement sheet for specific scenarios. (optional)
metering
Installation Tips: (a) If possible, do not install a valve upstream if it is going to be
throttled. Install on the downstream a minimum of 6 diameters from the taps/nipples* scale
ORIPAC. (b) The use of straightening vanes is not necessary for most
applications.
1 2
Actual Installation: (a) Insert bolts through bottom half of the flange bolt circle.
(b) Slide ORIPAC between flanges (make sure arrow on ORIPAC faces in the
1) Bore dia. (b)
direction of flow) (c) Make sure pressure connections are properly positioned. 2) Line dia. (D)
ORIPAC can be installed vertically or horizontally. For horizontal liquid lines, 3) Oripac O.D.
install the ORIPAC with the connections on or under the horizontal center line. 4) Flange bolts
For horizontal air or gas lines, install with the connections on or above the (face view) 5) Flange O.D.
horizontal center line. They should also be correctly oriented so as to not be
blocked by bolts when remainder of bolts are inserted: (d) Add rest of bolts and
nuts leaving all bolts loose so ORIPAC is free to move. (e) If necessary, the ORIPAC *Bolts should be 1.25” longer than standard
can be centered using a steel ruler to measure the total side to side movement make up flange bolts to accommodate ORIPAC thickness.
and set ORIPAC at half way point all around. (f) Lubricate & tighten bolts
alternating diametrically. (g) Check to insure the ORIPAC is installed with the Optional Connection Kit:
arrow facing in the same direction as flow. Includes 1/4" PVC Extension Nipples with
1/4" Port Ball Valves - FNPT Ends.

Toll-Free: 1-800-587-5423 · Tel: (631) 587-1000 · Fax: (631) 587-1011


LAMBDA SQUARE, INC. 71 Deer Park Avenue · Babylon, NY 11702-2801 USA
www.LambdaSquare.com · email: [email protected]
© Copyright Lambda Square, Inc. All rights reserved.
ORIPAC FLOW METERING SYSTEM
Dimensional Drawing: FLOW (OPTIONAL BI-DIRECTIONAL)
All standard dimensions are designed for 150# Rated ANSI Flanges
1-1/4”
but can be customized as required.
INCLUDING HI PID LOW 1/2” 1/4” NPT
• Weight: Varies with line size and model. 1/8” THICK OD PRESSURE
RING FITTINGS
NAMEPLATE
• Pressure: Limited only by pipe and flange rating restrictions. GASKETS
ADHERED
(ISO, 300, 600, 900, ANSI, 1500, 2500#) TO ORIPAC
FACES

• Temperature: 0° F to +140° F (dependant on material and ORIFICE


PLATE CD
gasketing) 1/8” THICK
TYPICAL
• Head Loss: Similar to standard orifice plates. (See ref. sheet)
• Fluids: Most liquids, gases. High temperature, corrosive, etc.
• Line Sizes: 1/4" to 24" standard. Specials to 60". Custom
fabrications available. ORIPAC
BODY
(CARRIER
• Installation: Standard ANSI flange, 150# STD. (orifice flanges RING)
not required)
• Accuracy: 0.6% of full scale flow. (Refer to tech support sheet)
NOTE: High pressure tap shown on cross section for illustration only
• Pipe Requirements: Refer to installation sheet attached.
General requirements 10 Dia up and 5 Dia down Oripac Pipe
Line Tap
Outside Inside
• Bore: Concentric standard, eccentric, quadrant edge, Size Location
Diameter Diameter
segmental, multi bore available. Drain or vent hole available (D) (CD)
(OD) (PID)
on concentric bores
0.25" 1.890" 0.364" 4.5
0.50" 1.890" 0.622" 4.5

The Importance of Installation 0.75" 2.250" 0.824" 4.5


1.00" 2.625" 1.049" 4.5
The importance of proper pressure tap connections for orifice 1.25" 3.000" 1.380" 4.5
plate installations is often minimized or overlooked in the field.
1.50" 3.375" 1.610" 4.5
Faulty connections nullify the precision of the machining in the
2.00" 4.125" 2.067" 4.5
manufacture of the orifice plate and calibration accuracy of the
secondary instrument. An ORIPAC, properly installed, will provide 2.50" 4.875" 2.469" 4.5
satisfactory, low-cost service over a wide capacity range. 3.00" 5.375" 3.068" 4.5
Lambda Square has developed the ORIPAC to combine accuracy of 4.00" 6.875" 4.026" 4.5
measurement with certainty of correct installation. 5.00" 7.750" 5.047" 4.5
The many advantages in their installation and operation clearly 6.00" 8.750" 6.065" 4.5
indicate the superiority of the ORIPAC for the majority of 8.00" 11.000" 7.891" 4.5
conditions under which an orifice installation is suitable. 10.0" 13.374" 10.020" 4.5
12.0" 16.125" 12.000" 4.5
14.0" 17.750" 14.000" 4.5
16.0" 20.250" 16.000" 4.5
18.0" 21.625" 18.000" 4.5
20.0" 23.875" 20.000" 4.5
24.0" 28.250" 24.000" 4.5

DIMENSIONS IN INCHES | Thickness = 1.25" On All Line Sizes

Toll-Free: 1-800-587-5423 · Tel: (631) 587-1000 · Fax: (631) 587-1011


LAMBDA SQUARE, INC. 71 Deer Park Avenue · Babylon, NY 11702-2801 USA
www.LambdaSquare.com · email: [email protected]
© Copyright Lambda Square, Inc. All rights reserved.
ORIPAC FLOW METERING SYSTEM
The ORIPAC utilizes the corner tap proportions as defined in ISO 5167. The ASME Fluid
Meters Research Committee has suggested that the dimensionless coefficient equation
developed by the International Standards Organization (ISO) and presented in ISO 5167 ORIPAC CAPACITY REFERENCE
is significantly better for the broad spectrum of flow measurement applications (WATER AT 60ºF) STD SCH PIPE
throughout process industries. Maximum Full
Line Size Inches
The coefficient values used in the ORIPAC bore calculations represent the same Scale Flow Rate
(Inches) of Water
confidence level assigned to the flange and radius taps widely accepted in fluid flow In GPM
measurement.
Differential Beta Ratio
The accuracy assigned to the coefficient values is ± 0.6% full scale flow for d/D (Beta) 0.23 0.75
values 0.2 to 0.6 and ± ß% for Beta values 0.6 to 0.75 (i.e. ß of 0.7 would have an 1" 20" 0.8 10.5
uncertainty value of ± 0.7% full scale flow). 320 3.2 42
1 1/4 20 1.2 13
Accuracy of the differential signal produced by the ORIPAC equals or exceeds that of a
320 5 72
properly manufactured and installed flange or radius tap orifice meter.
1 1/2 20 1.8 23.5
320 7.2 94
HEAD LOSS: Overall Pressure Loss Across Thin-Plate Orifices 2 20 3.2 41.6
320 12.9 167
OVERALL PRESSURE LOSS 2 1/2 20 5 65
HEADLOSS AS % OF MAXIMUM

320 20 260
DIFFERENTIAL PRESSURE

3 20 7 95
320 28 375
4 20 13 170
320 52 670
5 20 20 260
320 80 1050
6 20 29 375
320 116 1500
8 20 52 670
BETA/AREA RATIO (%) (ORIFICE BORE/PIPE ID) 320 208 2680
10 20 80 1050
320 320 4200
The above curved graph shows pressure loss generated by the ORIPAC. For
12 20 116 6000
example, a 0.6 Beta Ratio (d/D) would show a loss of 62%. This is also shown
320 460 2050
on the linear graph area ratio (d/D)² =.38 with a loss of 62%.
14 20 160 2050
320 640 8500
As a quick check reference, use the formula:
16 20 206 2700
Headloss=1-Beta Ratio² eg: 1-.62² or 1 - .38 = 62% of the differential pressure.
320 820 10800

Toll-Free: 1-800-587-5423 · Tel: (631) 587-1000 · Fax: (631) 587-1011


LAMBDA SQUARE, INC. 71 Deer Park Avenue · Babylon, NY 11702-2801 USA
www.LambdaSquare.com · email: [email protected]
© Copyright Lambda Square, Inc. All rights reserved.
ORIPAC FLOW METERING SYSTEM
Suggested Specifications:
GENERAL: This specification describes a differential pressure type of ACCURACY: The orifice primary shall be precision calculated, bored
metering primary for the main line metering of air or gas in a _____" and bench calibrated to ASME & ISO specifications yielding a
pipe. The orifice plate flow meter "ORIPAC Model 4150-P" wafer type predictable accuracy of +/- 0.6 % of full scale flow. Calculations shall be
unit shall include high & low metering taps utilizing a "corner tap" performed by Lambda Square, Inc. to determine exact differential &
configuration. Orifice primary shall meet or exceed ASME headloss at full scale & normal flow conditions.
requirements for corner style metering taps with regards to accuracy, Accuracy must be substantiated by flow calibration data obtained on
tolerances & calculations. A flow vs differential pressure curve shall be metering the same flow elements. Flow calibration data must replicate
provided for each set of flow conditions. line size, comparable flow range and Reynolds #. Certified calibration
MOUNTING: The orifice metering primary shall be suitable for must have been performed in at least three physically independent
installation between standard ANSI flanges (any rating/material) and recognized flow calibration facilities. Calculation formulas shall be
mounted on standard pipe (any material). The unit shall be "self based on ASME guidelines. The orifice primary shall be tested under
centering" within the bolt circle of the flanges. No alignment of the similar conditions for at least 10 years and shall be equal in all respects
orifice shall be necessary. Drilling and or tapping of the main or flanges to ORIPAC Model 4150-P as manufactured by Lambda Square, Inc. of
will not be allowed or required. The overall laying length shall be 1.25" Babylon, NY.
including pre-attached ring type 1/8" thick Buna "N" Gaskets. Other METER PERFORMANCE: Calculations for pressure loss may be
gasket materials available upon request. performed in conjunction with the ORIPAC flow calculations by
CAPACITY: Normal flow rate of ____SCFM or ____ PPH or ____GPM at Lambda Square, Inc. The overall pressure loss and differential pressure
a differential pressure to be determined by Lambda Square Inc. at shall be determined at maximum & normal flow conditions. The
pressures & temperatures provided by engineer and calculated by permanent headloss shall be within the requirements of the
Lambda Square Inc., Orifice Flow Calculating Software. application, and determined by the engineer in conjunction with
MATERIALS OF CONSTRUCTION: The ORIPAC Model 4150-P primary Lambda Square, Inc.
element shall be monolithic (single piece) constructed entirely of PVC.
Metering connections shall be 1/8" or 1/4" NPT female taps. Hose barb
connections or extension nipples may be threaded to high & low
pressure connections if desired.

Toll-Free: 1-800-587-5423 · Tel: (631) 587-1000 · Fax: (631) 587-1011


LAMBDA SQUARE, INC. 71 Deer Park Avenue · Babylon, NY 11702-2801 USA
www.LambdaSquare.com · email: [email protected]
© Copyright Lambda Square, Inc. All rights reserved.
ORIPAC FLOW METERING SYSTEM
THE ORIPAC ADVANTAGE
Integrated metering taps properly located and predrilled – Used with Bi-directional flow capabilities – Orifice plate available without bevel
standard ANSI flanges - orifice flange unions eliminated. No to accommodate flow in both directions.
drilling/tapping pipe.
Orifice plate thickness option – Thickness of orifice plate provided
Full faced integral gasket pre-attached – Precludes potential according to ASME/AGA specs standard. Can be provided with special
alignment problems during installation. plate thickness to address high pressure lines, thick bore "critical flow"
requirements, etc.
Self-centering within standard flanges – ORIPAC O.D. sits snug within
bolt circle of specified flange rating insuring concentricity - centering Available for any flange material or rating (125/150#, 250/300#,
devices or additional components eliminated. 600#, 900#, 1500#, 2500#) DIN Ratings or custom flange
requirements – Eliminate potential flange rating mismatches, no need
"Corner" type metering taps – Established coefficient accuracy values.
for additional centering devices - ideal for use within lightweight duct
Solid-state PVC construction – Use or superior high-tech materials flanges.
eliminating rusting and plugging of sensing ports.
Ideal for light weight duct measurement – Mounts between thin angle
Custom Manufacture (able to meet specific temp and pressure or plate flanges for lightweight installation.
requirements) – Standard configurations available from stock, custom
Can be used within cast iron standard flanges. (Orifice flanges not
units available in different materials, thickness and configuration to
available in cast iron) – Simple orifice device now available for cast iron
meet specific requirements for harsh applications.
piping without welding.
Proven through a wide and varied range of applications and
Can be sized for restriction or pressure drop control in conjunction
installations since 1984 – Ten (10) year history of reliability and
with flow measurement – Eliminate additional throttling valve by
accuracy.
combining flow meter and restrictor as one integral unit.
Sized for specific pipe schedules or special inside pipe diameters
Port size (Pizometer through hole) can be increased if required –
including US/Metric, etc – Insures accuracy by eliminating pipe inside
Reducing the chance of plugging in lines containing particulates, solids,
diameter to ORIPAC inside diameter mismatches.
etc.
Available with any bore size to produce any specific differential
Metering Taps drilled "straight through" to the pipe I.D. – Easily
pressure – Ability to match range on an existing d/p transmitter or
accessible and cleaned using pipe cleaner or rod out kit.
indicating gage without recalibration or replacement.
Can be used with Lambda flange mount bracket for installing
Orifice bore calculated to match specified "headloss" requirements –
instrumentation – Option for direct mount installation of manifold
Exact differential pressure values and overall system head loss can be
transmitter or indicating gage offering consolidated installation
calculated and pre-determined.
(Remote mount also available)
Orifice bore styles available include Concentric, Eccentric, Segmental,
Pre-attached nameplate – Serial #, Tag #, ID, Bore and other
Quadrant edge, multiple bore – Able to address challenging flow
information available. Also available: SS attachment w/SS wire or
applications including: low viscosity fluids, gasses containing liquids,
w/RTJ type nameplate holder.
limited pipe runs, etc.
Flexible readout options – Can be used with any Transmitter, Gage,
Drain hole at bottom or vent hole at top available for orifice plate.
Manifold arrangement.
Additional tap can be installed for drainage purposes – Orifices may
require a drain at bottom of orifice to allow passage of condensate. Air Standard valve kit available – Includes nipples and shutoff valves to
in liquid lines may require a vent hole at top of orifice. streamline installation.

Toll-Free: 1-800-587-5423 · Tel: (631) 587-1000 · Fax: (631) 587-1011


LAMBDA SQUARE, INC. 71 Deer Park Avenue · Babylon, NY 11702-2801 USA
www.LambdaSquare.com · email: [email protected]
© Copyright Lambda Square, Inc. All rights reserved.
ORIFICE PLATES
INDUSTRY-STANDARD TYPES and
CUSTOM CONFIGURED ORIFICE PLATES
Sizes available: 1/4” and up
Materials: 304 / 316 Stainless, MONEL, Exo cs
Standards Apply: AGA | API | ASME | ISA | ISO 5167
Every piece quality-checked

FOR ALL INDUSTRIES and APPLICATIONS


CUSTOM PRECISION FABRICATION
DESIGN and APPLICATION ASSISTANCE

Every feature of Lambda Square Orifice Plates


can be customized to your requirements!
MATERIAL · DIMENSIONS · BORE · COUNTERBORE
FLOW EDGE · BEVEL · TAB · ID INFO
Toll-Free: 1-800-587-5423 · Tel: (631) 587-1000 · Fax: (631) 587-1011
LAMBDA SQUARE, INC. 71 Deer Park Avenue · Babylon, NY 11702-2801 USA
www.LambdaSquare.com · email: [email protected]
© Copyright Lambda Square, Inc. All rights reserved.
ORIFICE PLATES
Illustrations are representative of only a few of the possible configurations.

T T

R R
O TE
B

B
O

O
B UN
E
R

R
E

E
O
Counter

C
Bore
45° Dia (D)

FLOW FLOW D
Edge Edge

Square Edge Concentric Bore & Bevel Square Edge Concentric Bore & Counterbore
Concentric orifice with a square edge. Edge thickness Square edged orifice. Throat is reduced by upstream
is limited with a downstream beveled bore. Most counterbore.
common and economical type of orifice plate.

T T

COUNTER
BORE
R R
O TE

B
B UN
E

O
R
O

E
C

45°
FLOW FLOW D

Edge
D A

LINE ID LINE ID

Eccentric Bored Orifice Segmental Bore Orifice


Popular in water treatment, oil, and paper industries – For flows with entrained solids or heavy sediments.
anywhere flow contains solids and for slurries. Bore Bore may be at the bottom or top of pipe depending
edge is typically inscribed in a circle 98% of line ID. on type of flow and type of unwanted materials.

T T

45° Bore
Dia (D)
FLOW FLOW
Edge

Conditioning Orifice Plate Restriction Bore


Holes may be at bottom of pipe to minimize restriction Not for flow measurement. Drops pressure and
of flow, prevent ‘damming’ effect. Especially for short reduces flow. No bevel and no limit to Beta ratio.
straight pipe runs and tight fit applications.
Toll-Free: 1-800-587-5423 · Tel: (631) 587-1000 · Fax: (631) 587-1011
LAMBDA SQUARE, INC. 71 Deer Park Avenue · Babylon, NY 11702-2801 USA
www.LambdaSquare.com · email: [email protected]
RTJ ORIFICE PLATES
Ring Type Joint (RTJ) orifice plates are recommended for clean
liquids, gases and low velocity steam flows.
RTJ orifice plates incorporate integral gaskets for installa on
between ring-type joint flanges. Based on proven technology,
there are no moving parts and they are suitable for high-
temperature and high-pressure applica ons.
Plate thickness depends on line size and differen al pressure
and should be sufficient to prevent the plate from deforming
under opera ng condi ons.
RTJ type orifice plates may be machined in one piece, or
alterna vely from two pieces, with an orifice plate screwed onto
a carrier ring/gasket.

Orifice plates can be made in accordance with


customer drawings as required.
RTJ type orifice plates can be supplied complete
with ANSI B16.36 orifice flanges.
Plate and handle are either one-piece seamless
design or the handle is welded to the plate –
depending on size and ASME class.
Flange ASME class and other standard info is
stamped on the handle.

Toll-Free: 1-800-587-5423 · Tel: (631) 587-1000 · Fax: (631) 587-1011


LAMBDA SQUARE, INC. 71 Deer Park Avenue · Babylon, NY 11702-2801 USA
www.LambdaSquare.com · email: [email protected]
SEAL POTS
Seal Pots/Condensate Chambers
Condensate chambers are used as a barrier between the main line and
the secondary instruments in the measurement of steam or other
vapors which condense to a liquid state insuring compatibility with the L
secondary instruments. They can also be used to cool down very high
temperature liquids. Seal pots are installed where the line fluid is
corrosive or viscous to the extent where it cannot be permitted to
contact the secondary instrument (transmitter or gage) thereby acting D
as a liquid barrier between the line fluid and the condensate.
Material: Available in carbon steel, stainless steel, P22 and other alloy
steel and other materials. Standard pipe sizes are 2" through 6" and
pressure ratings for carbon steel as indicated on the enclosed chart.
Connection fittings are NPT or welded socket adaptors. Chambers can
be hydrostatically tested and x-rayed upon request. ISO and ISA STYLE 1 STYLE 2 STYLE 3 STYLE 4
standards are typically followed unless otherwise specified. Welding
can be to ANSI 1331.1 code if required.
Typical industry applications include: refineries, power plants, Connections are 3000# or 6000# welded half couplings, NPT or
chemical & petrochemical, steel plants and other process industries. socket weld. Connections available in any quantity or arrangement.
Installation: Either vertical or horizontal lines between the primary Sizes: 2" – 6" Standard
(Flow Meter) and the secondary (transmitter/gage) to act as steel or
Schedules: STD SCH, XH, XXH, (others available)
barrier to the line fluid permitting direct sensation of the flow
conditions. Units should be mounted at the same level minimizing
possible error that could arise due to unequal head of fluid in the
connecting pressure lines.
Please provide the following information for a specific quotation:
Initial sizing of the required liquid level in the seal pots is function of the
Pipe Size and Schedule
flow parameters. The basic rule of thumb is that the level in the
chambers should equal the total volume of condensate in the Material
transmitter and the sensing lines. This also complies with ASME Style (Refer to drawing): Location and Number of Taps
requirements. Exact capacity is also contingent on a number of other Quantity Required
issues including: relative humidity, dew point, pressure, flow rate, etc.
Standard maintenance includes draining/filling as necessary.

Toll-Free: 1-800-587-5423 · Tel: (631) 587-1000 · Fax: (631) 587-1011


LAMBDA SQUARE, INC. 71 Deer Park Avenue · Babylon, NY 11702-2801 USA
www.LambdaSquare.com · email: [email protected]
STRAIGHTENING VANES
Straightening Vanes ½” Pipe Plug
(Tube Bundle Type) Half Coupling
Weld
Installed upstream of flow meter when adequate upstream pipe To Pipe
Socket
run section can not be met. Proper installation will straighten Countersunk Set Screw
out flow profile to increase metering accuracy. Available in Hole in
carbon steel, stainless steel and other alloys. Perforated plate Pipe Wall
Welded Pad
and vane type flow straighteners also available.

Vane
Bundle

Line Approximate
Model Weights
Line Vane Line Vane Vane Tube Tube No. of Screw Flange Line Flange
Spacer Size Type I.D. Length O.D. O.D.* Wall Tubes Size Model Model O.D.
Lug
TYPE I A B D E LBS. LBS. C
CONCENTRIC MODEL 2 I 2.067 6 1 31/32 21/32 .095 7 1-3/8 x ¾ 3 2 3 5/8
2 I 1.939 6 1 29/32 21/32 .095 7 1-3/8 x ¾ 3 2 3 5/8
3 II 3.068 8 2 7/8 19/32 .049 19 1-3/8 x ¾ 4 3 5
3 II 2.900 8 2¾ 9/16 .049 19 1-3/8 x ¾ 4 3 5
4 II 4.026 10 3 31/32 13/16 .049 19 1-3/8 x ¾ 8 7 6 3/16
4 III 3.826 10 3¾ ¾ .049 19 1-3/8 x 1 8 7 6 3/16
5 II 5.047 12 4 27/32 1 .049 19 1-1/2 x 1 11 9 7 5/16
Spacer
Lug 6 II 6.065 12 5 15/16 1 7/32 .049 19 1-1/2 x 1 21 19 8½
TYPE II 6 II 5.761 12 5 5/8 1 5/32 .049 19 1-1/2 x 1 21 19 8½
CONCENTRIC MODEL
8 II 7.625 16 7 15/32 1½ .065 19 1-1/2 x 1 37 35 10 5/8
8 II 7.981 16 7 29/32 1 5/8 .065 19 1-1/2 x 1 37 35 10 5/8
10 III 10.136 20 10 2 .083 19 1-1/2 x 1 57 54 12 ¾
10 II 10.020 20 9¾ 2 .083 19 1-1/2 x 1 57 54 12 ¾
12 III 12.090 24 11 7/8 2 3/8 .083 19 2-1/2 x 1 ¼ 81 77 15
12 III 11.374 24 11 ¼ 2 ¼ .095 19 2-1/2 x 1 ¼ 81 77 15
12 II 11.938 24 11 5/8 2 3/8 .083 19 2-1/2 x 1 ¼ 81 77 15
Spacer
Lug 14 III 13.25 28 13 1/8 2 5/8 .083 19 2-1/2 x 1 ¼ 105 100 16 ¼
TYPE III 14 II 13 28 12 ¾ 2 5/8 .083 19 2-1/2 x 1 ¼ 105 100 16 ¼
CONCENTRIC MODEL
16 III 15.250 30 15 3 .188 19 2-1/2 x 1 ¼ 274 268 18 ½
16 II 15.500 30 14 18/32 3 .188 19 2-1/2 x 1 ¼ 274 268 18 ½
18 II 16.876 36 16 23/32 3 7/16 .188 19 2-1/2 x 1 ¼ 386 378 21
20 II 19.250 40 18 27/32 3 7/8 .188 19 2-1/2 x 1 ¼ 477 468 23
24 II 23.250 48 23 1/8 4¾ .188 19 2-1/2 x 1 ½ 704 693 27 ¼
26 III 25.250 52 25 5 .188 19 2-1/2 x 1 ½ 814 796 29 ½
30 III 29.250 60 28 ¾ 5¾ .188 19 2-1/2 x 1 ½ 1295 1273 33 3/4
34 II 33.250 68 32 13/16 6¾ .250 19 2-1/2 x 1 ½ 1880 1860 38
36 III 35.250 72 35 7 .188 19 2-1/2 x 1 ½ 1582 1559 40 ¼

Toll-Free: 1-800-587-5423 · Tel: (631) 587-1000 · Fax: (631) 587-1011


LAMBDA SQUARE, INC. 71 Deer Park Avenue · Babylon, NY 11702-2801 USA
www.LambdaSquare.com · email: [email protected]
FLOW NOZZLES
Flow Nozzles
Used for Gas, Liquid and Steam Flow Measurement
Standard Sizes: 1/8" - 60", All Flange Ratings. Available in
stainless steel, carbon steel, brass, fiberglass, spun
aluminum, PVC, Hastalloy, Monel and other materials.
Available in all line sizes and throats. Sized for standard,
critical or sonic flow conditions. Also can be provided as
part of an ASME nozzle meter run with piping, flanges,
calibration, etc.

The "STANDARD" FLANGE FLOW The "WELD-IN" FLOW NOZZLE style is


NOZZLE style is the most commonly used designed to be installed permanently in
Flow Nozzle. It is designed to be inserted a pipe section. This nozzle has a specially
between pipe flanges. A special machined step on its outside diameter
machined shoulder on the back side of that is used to align a beveled inlet and
the flange assures the proper alignment outlet bored pipe section. This type
of the nozzle with the pipe I.D. This style nozzle is widely used where high
Flow Nozzle utilizes pipe wall taps whose temperature and pressure applications
location is determined by the Beta Ratio. prohibit the use of pipe flanges such as in
power plant and feed water installations.
Pipe wall taps are utilized with this style.

The "TAPPED" TYPE FLANGED FLOW The "HOLDING RING" FLOW NOZZLE
NOZZLE is similar to the "FLANGE" style, style is designed so that the welding of
but includes a downstream tap (usually a dissimilar materials is eliminated, A
1/2" connection) provided in the flange special holding ring and locating pins are
of the nozzle. This style nozzle is made of the same material as the pipe
recommended in smaller line sizes that the nozzle Is to be installed in. This
where the downstream tap may allows for the nozzle to be offered in a
i nte r fe re w i t h t h e p i p e we l d o r wide range of materials. This style is not
downstream mounting flange. recommended for line sizes below 4
Inches.

"Throat tap" type flow nozzles also available.

Toll-Free: 1-800-587-5423 · Tel: (631) 587-1000 · Fax: (631) 587-1011


LAMBDA SQUARE, INC. 71 Deer Park Avenue · Babylon, NY 11702-2801 USA
www.LambdaSquare.com · email: [email protected]
VENTURI FLOW METERS
Model 2300 Venturi Flow Meter Features
Very Low Permanent Pressure Loss
When Low Headloss is a Priority!
Low Cost 1/3 the Cost of Cast Iron
The Model 2300 offers short laying length, easy installation, Corrosion Resistant
high accuracy, and very low permanent pressure loss. It is
corrosion-resistant and carries minimal maintenance Excellent Flow Measurement
requirements, making it as economical as it is accurate and Accurate
consistent. Easy Installation
These easy to install, low maintenance devices provide reliable Minimal Maintenance - Set it and forget it!
performance and minimal headloss for a wide range of
Long Service Life
municipal and industrial applications.

Made of dimensionally stable fiberglass-


reinforced vinyl ester epoxy – ensuring LONGITUDINAL SECTION OF MODEL 2300 VENTURI
accurate flow measurement and long life.
Highly corrosion resistant, self-scouring,
and accommodates a wide range of line
fluids, line pressures and temperature
conditions up to 350°F.
10.5° CONE
It can be supplied with bronze, stainless 5° CONE

steel, or other metal throat materials.


The carbon steel holding flange is coated FLOW DIRECTION

with vinyl ester epoxy and has 316


stainless steel pressure connections. The
Model 2300 comes ready to install with
neoprene flange gaskets to fit pipes from All fiberglass reinforced
vinyl ester
3/4" to 120". Also available with stainless
throat and flange

A wide range of standard and custom sizes for your application!

HEAD LOSS CURVE PIPING CURVE


12 25

10
Diameters Upstream from Venturi
Corner Tap Headloss (% of dP)

20
Recommended Straight Pipe

8
15
6 Elbow – Short Radius
10
4 Increaser
5
2
Reducer

0 0
0.3 0.35 0.4 0.45 0.5 0.55 0.6 0.65 0.7 0.75 0.8 0.3 0.35 0.4 0.45 0.5 0.55 0.6 0.65 0.7 0.75 0.8
Beta Ratio Beta Ratio

Toll-Free: 1-800-587-5423 · Tel: (631) 587-1000 · Fax: (631) 587-1011


LAMBDA SQUARE, INC. 71 Deer Park Avenue · Babylon, NY 11702-2801 USA
www.LambdaSquare.com · email: [email protected]
VENTURI FLOW METERS
Model 2350 Venturi Flow Meter Features
Short Laying Length
For Tight Space Requirements!
Low Permanent Pressure Loss
The very short-laying length Model 2350 provides high accuracy Low Cost – 1/3 the Cost of Cast Iron
and low permanent pressure loss while minimizing space
requirements. The flow conditioning within the inlet section Corrosion Resistant
allows for closer coupling with upstream pipe fittings. Easy Installation Between ANSI Flanges
These easy to install, low maintenance devices provide reliable Minimal Maintenance – Install it and forget it
performance and minimal headloss for a wide range of Consistent Accuracy
municipal and industrial applications. Long Service Life!
A wide range of standard and custom sizes for your application!

Made of dimensionally stable fiberglass-


reinforced vinyl ester epoxy – ensuring LONGITUDINAL SECTION OF MODEL 2350 VENTURI
accurate flow measurement and long life.
Highly corrosion resistant, self-scouring,
and accommodates a wide range of line
fluids, line pressures and temperature
conditions up to 350°F.
40° CONE
5° CONE
It can be supplied with bronze, stainless 7°

steel, or other metal throat materials.


FLOW DIRECTION
The carbon steel holding flange is coated
with vinyl ester epoxy and has 316
stainless steel pressure connections. The
Model 2350 comes ready to install with
neoprene flange gaskets to fit pipes from Fiberglass reinforced
vinyl ester with stainless steel
3/4" to 120". throat liner and
stainless steel flange

HEAD LOSS CURVE PIPING CURVE


14
25
Diameters Upstream from Venturi

12
Corner Tap Headloss (% of dP)

Recommended Straight Pipe

20
10

8 15
Elbow – Short Radius
6 10
Increaser
4
5
Reducer
2
0
0 0.3 0.35 0.4 0.45 0.5 0.55 0.6 0.65 0.7 0.75 0.8
0.3 0.35 0.4 0.45 0.5 0.55 0.6 0.65 0.7 0.75 0.8 Beta Ratio
Beta Ratio

Toll-Free: 1-800-587-5423 · Tel: (631) 587-1000 · Fax: (631) 587-1011


LAMBDA SQUARE, INC. 71 Deer Park Avenue · Babylon, NY 11702-2801 USA
www.LambdaSquare.com · email: [email protected]