2csc004033b0201 ABB
2csc004033b0201 ABB
bol.it.abb.com
ISOLTESTER-DIG, SELVTESTER-24,
insulating monitoring insulating monitoring
devices for 230 V a.c. devices for SELV 24
IT-M circuits V a.c./d.c. circuits
supplying scialitic lamps
ArTu enclosures
TI isolating QSO floor standing switchboards
are assembled with ArTu K
transformers for enclosures
medical use
It grants protection against indirect
contacts without breaking the
supply during the first fault to earth. DDA 200 RCD block
ABB TI allows also to completely
It protects emergency section in case
control the overtemperature on the
of leakage current to earth
primary and secondary windings due
to overload.
OVR surge
protection
ISOLTESTER-DIG-RZ
Designed for the safeguard of
electric devices from transient Insulating monitoring device for
overvoltages group 2 medical locations
fault detection
S200
Miniature circuit Technical
brakers documentation
Instruction manual for switchboard
They protects IT-M circuits from short installation, commissioning and
circuits and overloads maintenance is located inside the
switchboard
Equipotential
bonding bus bar
Extraneous conductive parts must
be wired on the equipotential node
Narrow in depth
Wall mounted QSO shall be
installed inside compartments or
nooks
ArTu Enclosures
Wall mounted QSO are
assembled with ArTu M eclosures
IT-M system
Supply
IT-M circuits
TEST
prova pushbutton
TEST pushbutton
MUTE pushbutton
Equipotential
bonding bus bar
Advantages of ISOLTESTER-DIG-PLUS:
- reliability of the monitoring under any
operational condition thanks to its codified
signal
- integration with supervision systems through
ModbusRTU protocol via RS485 serial port
- fault analysis by means of maximum and
minimum values measurement
- warning signal shall be delivered up to 4
rooms where medical and technical staff is
Despite network ripples and ISOLTESTER -DIG-PLUS avoids present
disturbances... unwanted trippings - complete control of any alarm thanks to a
programmable relay
ISOLTESTER-DIG-RZ
- Quality: the recognized standard in
hospital
- Specialization: properly designed for
hospitals
- Completeness: all electrical and
thermal parameters controlled by a
single device
- Flexibility: adjustable thresholds
according to the parameters
monitored
- Strength: high resistance to network
interference
Functioning principle
Insulation resistance is measured by applying a direct
current signal between the isolated line and earth: the level
of insulation can be determined by measuring the leakage
current to earth. ISOLTESTER-DIG-RZ ensures an effective
measurement of the insulation resistance even in the presence
of strong interference and high harmonic or direct-current
components, due to its sophisticated digital filter.
Programming
The device offers broad programming possibilities through its
user-friendly digital display menu and four selection keys.
Red LED, R:
Led indicating insulation
resistance (kΩ), it blinks when Red LED, Error/Link Fail:
the parameter is out of range Led indicating internal fault alarm,
no link to the line or temperature
probe failure
Red LED, Z:
Led indicating insulation
impedance and line capacity,
it blinks when the parameter
is out of range
TEST | ENTER:
Button for device testing. And
confirmation of the programmed
parameters
Red LED, T1:
Led indicating temperature
on the 1st probe, it blinks when
the parameter is out of range
RESET | SET:
Buttons for device programming
Red LED, T2:
Led indicating temperature
on the 2nd probe, it blinks when
the parameter is out of range
A Control room
1 2 3 4 5 6
ModbusRTU
Microswitches
They allows to set the alarm
threshold from 10 to 50 kΩ, as
shown in the picture.
TEST pushbutton
It tests that the device is working
properly
The QSD remote signalling panel enables to control - Compact: narrow dimensions
the alarms from the insulation monitoring devices from
remote. Alarms shall be delivered to all rooms under
- Easy: it can be installed in a common
supervision of medical or technical personeel. 3 modules flush mounted box
- Reliable: it is immediate to recognize
The QSD panels provide an acoustic and luminous indication
for low isolation or thermal and electric overload. In
the fault type
addition, they have a TEST button to check their operating - Comfort: all QSDs in parallel shall be
status and a pushbutton for turning off the acoustic indication muted in a single touch
provided by the embedded buzzer.
They are assembled in universal 3-module flush-mounted
- Efficiency: both visual and acoustic
boxes. signalling
Probe 1
1: to 28 terminal of ISOLTESTER-DIG
PE 2: to 28 terminal of ISOLTESTER-DIG
3: to 30 terminal of ISOLTESTER-DIG
Probe 2
4: to 25 terminal of
230
SCH
0
ISOLTESTER-DIG
5: to 25 terminal of
PC
0
230
1
2
ISOLTESTER-DIG
3
4
5
6
6: to 27 terminal of
ISOLTESTER-DIG
Serial number
all ABB customers can receive the
test report by communicating the
serial number printed on the base
of each TI
Technical features
Rated power 3 kVA 5 kVA 7,5 kVA 10 kVA
Wall mounted QSO Rated voltage [V] 230/230 230/230 230/230 –
Rated current [A] 13,63 22,72 34,09 –
Dimensions LxHxD [mm] 700 x 1150 x 210 700 x 1150 x 210 700 x 1150 x 210 –
Floor standing QSO Rated voltage [V] 230/230 230/230 230/230 230/230
Rated current [A] 13,63 22,72 34,09 45,45
Dimensions LxHxD [mm] 538 x 2250 x 365 538 x 2250 x 365 538 x 2250 x 365 538 x 2250 x 365
Overall dimensions
Front view Side view Front view Side view
700 210 538 365
600
PV 4060
1123
1100
1000
1151
2250
PO 6069
629
751
Top view
130
69
130
210
556
Wall mounted QSO Floor standing QSO
Input 1 2 3 Output 1
Output 2
6
5
6
QSD-DIG
230
Input 14 14 14 14
1 6 QSD-DIG
2 4 11 230
7 12
11
9 14
5 10
Id
8 9
3 13
Aux
Linea 24 V
Output 10
Output....
line
Output 1
Output 2
QSD
230/24-C
Displays Insulation resistance value with signalling of over fullscale value and direct earth fault
Value of measured temperature 0 ÷ 200 °C per channel 1
Value of measured temperature 0 ÷ 200 °C per channel 2
Value of measured current 0 ÷ 999 A
Value insulation impedance
Setting parameters
Link fail
Relays output status
Value of network capacity to earth
Min and max values of measured parameters
Connection Max. section 2.5 sqmm
Operating temperature -10...60 °C
Storage temperature -25...70 °C, humidity < 90%
Modules 6
Weight 0,5 kg
Housing Plastic self-extinguishing housing for 35 mm,
with transparent sealable plate
Protection degree IP20
Power consumption 5 VA
Standards IEC 60364-7-710, IEC 61557-8, EN 60255-6, UNE 20615
19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36
1 2 3 4 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 1 2 3 4 5 6 7 8 9 10 11 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 1 2 3 4 5 6 7 8 9 10 11
Other QSD-DIG
PE PE
S S S S
L L
PC
IT-M Load IT-M Load
N N
In case of insulating transformer with central socie (pc) In case of insulating transformer without central socket (pc)
19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36
RS485 2 1 CT .../5 A
(only PLUS PT100 PT100 Out.
version)
ISOL TESTER-DIG-RZ
ISOL TESTER-DIG-PLUS
QSD-DIG 230/ 24
V aux.* Insulation
115 V 115 V Link Fail control QSD-DIG 230/24
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 1 2 3 4 5 6 7 8 9 10 11
PE
S S
N
L3 IT-M Load
L2
L1
Insulating transformer
Overall dimensions
61 61
90
90
45
90
90
45
44 44
105 105
56 56
6 moduli
6 modules
Wiring diagram
SELVTESTER-24 QSD-DIG 230/24
1 2 3 4 5 6 7 8 9 10 11 1 2 3 C1 C2 C3 C4 X Y Z
Other QSD-230/24-C
PE
S S
L(+)
IT-M Load
N(-)
Insulating transformer
Overall dimensions
85,5
85,5
45
52,5 44
58
3 modules
Wiring diagrams
19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36
RS485 2 1 CT .../5 A
(only PLUS PT100 PT100 Out
version) SELVTESTER-24 QSD-DIG 230/24
ISOL TESTER-DIG-RZ
ISOL TESTER-DIG-PLUS
QSD-DIG 230/24
V aux.* V aux.* Insulation 1 2 3 4 5 6 7 8 9 10 11 1 2 3 4 5 6 7 8 9 10 11
115 V 115 V 115 V 115 V Link Fail control QSD-DIG 230/24 V+ V- OUT-NO OUT-C OUT-NC PE COM-S F-S V-P ACUS ACK OVER FAULT COMP TEST- TEST-S TEST+
1 2 3 4 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 1 2 3 4 5 6 7 8 9 10 11
PE
PE
OTHER
S S QSD-DIG 230/24
S S
L(+)
L
PC IT-M LOAD
IT-M Load
N(-)
N
ISOLTESTER-DIG SELVTESTER-24
19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36
ISOLTESTER- C ISOLTESTER-RZ
Vaux: 230Va.c.
PE
PE
OTHER
QSD-DIG 230/24
S S
S S
L
L
PC
PC
IT-M LOAD
N
N
Insulating transformer
ISOLTESTER-C ISOLTESTER-RZ
Overall dimensions
55
78
78
17
121
Technical features
Rated output 3 kVA 5 kVA 7,5 kVA 10 kVA
Electrical protection class 1
Thermal insulation class [°C] B 130 B 130 F 155 F 155
Operating temperature max [°C] 40
Primary winding voltage [V] 230
Secondary winding voltage [V] 230
Secondary current [A] 13 21,7 32,6 43,5
Inrush current max [A] 221 369 553 738
Fuse rated current on the [A] T 12,5 T 20 T 32 T 40
secondary winding
Power dissipation [W]] 120 150 260 320
Frequency [Hz] 50 - 60
Secondary winding leakage [mA] < 0,5
current to earth
Leakage current to earth [mA] < 0,5
Short circuit voltage drop < 3%
No load current [In] < 3%
Leakage current between [mA] < 3,5
windings
Dimensions [mm] 205 x 340 x 150 240 x 380 x 150 240 x 380 x 160 277 x 380 x 260
Weight [kg] 29,5 44 50,5 73
Standards IEC EN 61558-1; IEC EN 61558-2-15; IEC EN 62041
Overall dimensions
3 KVA 5 KVA 7,5 KVA 10 KVA
b [mm] 205 240 240 277
c [mm] 170 170 170 176
f [mm] 115 115 115 173
h [mm] 340 380 380 380
h
f c
p b
TI order codes
BbN
Rated output PT100 probe 8012542 Order code
EAN
3 kVA 2896005 2CSM110000R1541
5 kVA 2896104 2CSM120000R1541
7,5 kVA 2896203 2CSM130000R1541
10 kVA 2521204 2CSM140000R1541
3 kVA 2521402 2CSM210000R1541
5 kVA 2521501 2CSM220000R1541
7,5 kVA 2521600 2CSM230000R1541
10 kVA 2521709 2CSM240000R1541
Shock absorber 2CSM900000R1541
ABB SACE
www.abb.com