0% found this document useful (0 votes)
67 views

BT 1301 Regulator

regulador 1301

Uploaded by

panteramc
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
0% found this document useful (0 votes)
67 views

BT 1301 Regulator

regulador 1301

Uploaded by

panteramc
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
You are on page 1/ 8
Bulletin 71.1:1301 aren 2008 1301 Series High-Pressure Regulators Figure 1. Type 1301F Regulator Exterior Introduction The proven reliability and accurate regulation of the 1301 Series regulators (see Figure 1) make them ideal for numerous high pressure drop applications. They are direct-operated, high-pressure regulators designed for inlet pressures up to 6000 psig (414 bar). The Type 1301F can handle outlet pressures from 10 to 225 psig (0,69 to 15,5 bar) in three ranges and the Type 1301G can handle outlet Pressures from 200 to 500 psig (13,8 to 34,5 bar) in fone range, SPRING CASE Figure 2. Type 1301F Regulator Sectional ‘These multi-purpose regulators can be used as pilot supply or pressure-loaded regulators where high- pressure operating medium must be reduced for use by gas regulator pilots or pressure-loaded regulators. Their rugged design offers versatility for a wide variety of applications including air, gas, water, and other liquids. An optional spring case with a tapped vent and adjusting screw closing cap is available that enables the Type 1301F to be used as a pressure~ loaded regulator. & EMERSON. Process Management Bulletin 71.1:1301 Specifications Available Configurations Type 1301F: Direct-operated, high-pressure reducing regulator for inlet pressures to 6000 psig (414 bar) and cutie pressure ranges from 10 to 225 psig (0,68 to 15,5 bar) in three ranges Type 1301G: Directoperated, high-pressure reducing regulator for inlet pressures to 6000 psig (114 bar) and an outlet preccure range of 2000 500 psig (13,8 to 34,5 bar) Body Size and End Connection Style 41/4-inch (DN 6) NPT (one inlet and two outlet connections); ANSI Class 300 RF, 600 RF, and 1500 RF; or PN 25 (all flanges are 125 RMS) Maximum Inlet Pressure Air and Gas: 6000 psig (474 bar) Liquid with PTFE Disk: 1000 psig (68.9 bar) Liquid with Nylon Disk: 2000 psig (138 bar) Maximum Emergency Outlet Pressure” Type 1301F: 250 psig (17,2 bar) Type 1301G: 550 psig (37,9 bar) Outlet Pressure Ranges Type 1304F: 10 to 75 psig (0,69 to §,17 bar), 80 to 160 psig @,45 to 10,3 bar), and 100 to 225 psig (69010 155 bar) Type 1301G: 200 to 500 psig (13,8 to 34,5 bar) Pressure Registration Internal Recovery Coefficient K,: 0.72 Flow Capacities Air: See Tables 1, 2 and 3 Water: See Tables 4 and 5 €, Coefficients at 20% Offset Type 1301F. See Table 0 Type 1301G: See Table 7 Wide-Open Flow Coefficients for Relief Valve Si ‘8/64-inch (1,88 mm) Temperature Capabilities” Nylon Valve Disk and Neoprene Gaskets: -20° to 180°F (~28" to 82°C) Teflon (PTFE) Valve Disk and Fluoroelastomer (FKM) Gaskets: ~20° to 40°F (~29° to 204°C) not recommended for hot water service Teflon (PTFE) Valve Disk and Ethylenepropylene (EPDM) Gaskets: 40° to 300°F (40° to 149°C) Low Temperature Service Service to -65°F (-54°C) is available with low temperature bolting and special low temperature nitrile (NBR) O-rings to replace the gaskets Spring Case Vents ‘Type 1301F Brass Spring Case: Four $/32+nch (3,97 mm) holes ‘Type 1301F Stainless Steel Spring Cas ‘One 4/4-inch NPT connection ‘Type 13016: ‘One 4/8-inch NPT connection with screen Options + Closing cap over adjusting screw and 1/44ineh NPT tapped spring case vent (Type 1301F brass spring case only) Handwheel adjusting screw (Type 1301F only) Panel mounting spring case with T-handle adjusting screw (Type 1301G only) + Bracket for mounting regulator on yoke of control valve actuator Inlet fiter disk Approximate Weight 8 pounds (3,63 kg) Te pasate a sn is bln sy ee ~ continued - Bulletin 71.1:1301 Specifications (continued) Construction Materials ‘Standard Construction Body, Bottom Cap, and Spring Case: Forged brass or 316 stainless steel Orifice: 303 Stainless steel Valve Disks and Holder: Nylon and zinc-plated brass, teflon (PTFE) and zinc-plated brass, nylon. and 316 ctsinlece steel, or teflon (PTFE) and 316 stainless steel Orifice Yoke: Brass or 316 stainless stee! Valve Disk Collar: 303 stainless steel Elastomers: Neoprene, flucrostastomer (FKM), or ethylenepropylene (EPDM) Regulator Spring: Zinc-plated steel Valve Spring: 302 Stainless stee! Diaphragm Plate: Zinc-plated steel Adjusting Screw: Plated-steel Upper Spring Seat: Plated-steel Diaphragm: 302 Stainless steel NACE Construction Body and Bottom Cap: Forged brass or 316 stainless stee! ‘Spring Case: 316 Stainless steel Orifice: 316 Stainless ste! Valve Disks and Holder. Teflon (PTFE) and 316 stainless steel Orifice Yoke: 316 Stainless steel Gaskets: Fluoroelastomer (FKM) Bottom Cap O-ring: Fluoroelastomer (FKM) Regulator Spring: Zinc-plated steel Valve Spring: Inconel X760 Diaphragm Piate: Zinc-plated steel Adjusting Screw: Plated-stee! Upper Spring Seat: Plated-steet Diaphragm: K-Monel 1 Tre rossvatanparae isn in bleh and on seb nid ecole on Sasol bo orssd Principle of Operation ‘The 1301 Series regulators are direct-operated Downstream pressure is registered internally through the body to the underside of the diaphragm. ‘When downstream pressure is at or above set pressure, the disk is held against the seat and there is ne flow through the regulator. When demand increases, downstream pressure decreases slightly allowing the regulator spring to extend, moving the yoke and disk assembly down and away from the east. Thie allows flow through the body to the downstream system. Capacity Information Air Capacities Tables 1 and 2 give regulating capacities at selected pressures and outlet pressure flows in SCFH (at 60°F and 14.7 psia) and Nm%sh (at 0°C and 1,01328 bar) of air. To determine the equivalent capacities for other gases, multiply the table capacities by the following appropriate conversion factors: 1.29 for 0.6 specific gravty natural gas, 0.810 for propane, 0.707 for butane, or 1.018 for nitrogen. For gases of other specific gravities, divide by the square roct of the appropriate specific gravity, Bulletin 71.1:1301 To determine wide-open flow capacity for relief valve sizing, use one of the following equations: For Critical Pressure Drops Use this equation for critical pressure drops (absolute outlet pressure equal to one-half or less than one-half the absolute inlet pressure) ¢, where, gas fow rate, SCFH gas sizing coefficient | absolute inlet pressure, osia For Non-Critical Pressure Drops Use this equation for pressure drops lower than critical (absolute outlet pressure greater than one-half of absolute inlet pressure), a= [520 ez Foe Tar CP SIN Cy where, = gasflow rate, SCFH specific gravity of the gas = absolute temperature of gas at inlet, °Rankine gas sizing coefficient absolute inlet pressure, psia flow coeficient pressure drop across the regulator, psi bows A090 Then, if capacity is desired in normal cubic meters per hour at 0°C and 1,01325 bar, multiply SCFH by 0.0268, Liquid Capacities Tables 4 and 6 give regulating capacities in U.S. gallons ner minute and liters per minute of water To determine regulating capacities at pressure settings ot given in Tables 4 and 5, or to determine wide-open capacities for relief sizing at any inlet pressure, use the following equation, =c, (AP OG where, Q = liquid flow rate, GPM AP = pressure drop across the regulator, psi C= regulating or wide-open flow coefficient G = specific gravity of the liquid Maximum Allowable Pressure Drop for Liquid Pressure drops in excess of allowable will result in choked flow and possible cavitation damage. Choked flow is the formation of vapor bubbles in the liquid flowstream causing 2 cendition at the vena contracta ‘which tends to limit flow through the regulator. The vena contracta is the minimum cross-sectional area of the flow stream occurring just downstream of the actual physical restriction. Cavitation and flashing are physical changes in the process fluid. The change is from the liquid state to the vapor state and results from the increase in fluid velocity at or just downstream of the greatest flow restriction, normally the regulator orifice. ‘To determine the maximum allowable pressure drop for water: AP (allow) = K.P, ) where, AP = pressure drop across the regulator, psi K, = valve recovery coefficient P= __ absolute inlet pressure, psia To determine maximum allowable pressure drop for fluids other than water, use other Fisher sizing methods oF contact your local sales office for assistance. Installation ‘The 1301 Series regulators may be installed in any position. Spring case vents must be protected against the entrance of rain, snow, debris, or any other forefgn material that might plug the vent openings. The inlet connection is marked “In’ and the two outlet connections are marked ‘Out.” If'a pressure gauge is ‘not installed in one outlet connection, plug the unused connection. See Figure 3 for dimensions. Bulletin 71.1:1301 Table 1. Type 1301F Regulating Capacities — Air with 100 fo 750 psig (6,90 to 51,7 bar) inet Pressure CAPACITIES I SCFH (nih) OF AIR cunerpressune | ouner ance, SPRING Puet | PRESSURE et Pressure Pig NUMBER AND COLOR | SETANO, Bear coer Teo RANOCOLOR | SETTING, 101630) ra ma en “earn | are oreen | 10% boop | 20% Droop [10% Oroon | 20% Drowp | 10H Drop | 20% Droop Tanunnem | BEA] G00] zr] aceon] sco aa) scan) eocro| soon) rad oon wampsiosamssy | (249 | Jan Gan] dona] 42039] soo (2a)] tan call vom Go| Seo (298)] oan (222) ue 7616.17) | 2606.70] 400 (10.7)] 600 (18.1) 900 (24,1)] 800 (24,1)] 1400 (a7.$)] 1000 (26,8)] 1600 (42,0)| Wemesemn | ca | w0eso] so aaa) soca) ao cial ooreral war ao) eo aso) sar ao taraszzitaa Suen” | 100 (10 Seg uo] soon (an3}| son ll tana 203) caso Gee | Zam fr Toma Garn ea] a war 7a] ooo Gaui) wooo aeai] rr00 we] 1280 (02) za 90) ouesiaian ted | 28 (183) Soo raa)[_oo0 avai] woo eral] zian aes] rao0 onal] 0 (ra Table 2. Type 1501F Regulating Copacties — Air vith 1000 f0 2000 psig (68,9 to 198 bay) Inet Pressure CAPACITIES SOFH RinIn) OFA oumerpressure | _ouner ance, SPaNePneT | PRESSURE Tre Pressure, alg a) Nuupek anocavon | "Serre, 05 AND crm, ees) 10005) "a0 se) WH orep | aubrey | Xoo» | 20m oop | WHbreop | 20K Dreep Zam] mea | moan | soves | coca | sonem | oo am iompeanmsn | so gay | san tae) | aon fee | So asm | son ars) | amon am | sin 2) zine mein | meas | wmeen | moon | tomas | imam | iam ine Tomesown | rem | we cea | veo cay | —nmcss | —rra es) | rao na] —ra00 a2) Tavossziiaa soer | tania | remae | aooofann | rrmeasm | mance | rien | mm ima Tow 225@6e0m 847) 60 oa | rear eon | sae0ens, | seen a | —ms0 707) | ran ao | sore) routs nee |_2m Gisay | dana fora | aero cant | oro | somo | dma tansy | ason (itl Table 3. Type 1301G Regulating Capacties — Air OuTLETeRESsuRE | OUTLET CAPACITIES SOFA (TH) OF AR sane semnoeaar | ressure| orrser, aie Fressre Pols ba} NUMBER. AND COLOR, | SETTING, | PSIG (bar) Fig PSIG ber | PSIG mh oor [ soo es) | 7201617) | 1000 9) | soos) | wooo) | RO EH) Tews] wo eam] sora] Wo CN] a Oss) ro) cap] tos) Gam] um Gray soo aay | 214138] 260 7a] aon [2419] can (322) san ey] tooo Geen] 2oo0 (s36)| ron (383) “ 1) a0 (2i7)} sno f24'1)] 1350 (33.2)] 1700 46.3)] aon (23,6)| 2300 (1) 2700 (72-4)) BOO can.) atom 09910545 $5 roy] ro aaah Yoo fan] 20m foe] san fan] somo (oas)| eau ec) | ar fay - ‘ 15 (1,03)] ‘800 (21 4}] 1000 (25.8)} 1300 ¢34.e)] 1500 (40,2)] Y800 ¢42.8) soca} ira}. | 2 | vaio Gra] teon ta] samo gay] 2an0 ees] aeons) (a8 dono (esl) Zao (refn] sano tes] auna (vor | smn (12) Bulletin 71.1:1301 Table 4. Type 1301F Regulating Capacities — Water'* ‘OUTLET PRESSURE ‘ouneT ‘CAPACITIES IN GALLONS fiers) PER MINUTE OF WATER BASED ON20% DROOP ANGE, SPRING PaRT | PRESSURE Inet Pressure Pig ar) NUMBER.AND CoLOR, | "SETTING. PG far) PI fom) {00 6.30) 250 (17) 500 G4) 70617) | _1000 65.977 we @Bwsi 25 (1a) a0 (185) 073 (270) D9 a) To 13) TB (8) ieee 50 48], ma (135) es (38) 12 G24) 132 (900), 13 an) ere acl ha (13) 01 aa) 128 84) 182 (675), 1.53 40) Hwiaearmias | 7517 0a ea) 88 (333), 14 48) 10 554) 1-85 (8.26) Termes? (22 Ser 150 (103) - 101 (3a), i6t 21) 202 (755) 231 78) Tobe 22560010188 | 160 (103) 85 GAN) 55 a1) 736 (742), 74 (48) Hocsewsrca | gay Heal a Bor (348), 1 fess) 231 (86) 2.88 (100) re we bon TD Gon 38 bo a eer eTERTET Na Table 5. Type 13016 Regulating Capacties — Water” SEENGRANGE | omer eressune [___CHPAOTES N GALLONS pe PERMITE OF WATERERSED ONAVR DROP PARDO coos SETTING, Ine Pressure slg (ba) PSIG fox) PSIG (br) 300 @07) 200 45) 750 6) 7000 aay Mamanap esa Tr a Ta 17 (885) 2H ese) 25 Om Nismo Sher sn 345) 5 (753), 258 7, Te ps ee 00 EH ona TTS rae Table 6. Type 1301F C, Coefficients"? UTETPRESsURE | OUTLET TWF 1901F COEFFICIENTS BASED O120% DROOP RANGE. SPRING PART | PRESSURE Tala Pressure aig Gm) NUWBER AND coLoR. | “seTmis, re. PSIG fom) Pic toa [700 (a0) | 250.672) | coo Gas) | 760 Gin | s000 Gow) | s600 (aap) | z000 (ET euaaesm | Sura] oo Oss Gos Toa Tar Tose Tae mepomes™ | owen | ones os 082 Dos oss ihaas oat mein | oor oom Oost 1s Ns os) na Homeews | eID | oor Gee Ose ose os ‘nar teresa siver | wo tos | 0083 oop hors re ors Toom 225 (600m 155) | 150 109) 08s ooar ware are 07s rosie? pes | 25 UE uo ou5 i nose 031 Ter rose rr Fan 1D 79 BED by ol eta Tae Table 7. Type 13016 C, Cosficxents” ‘OUTLETPRESSURE | OUTLET TYPE 19016 6, COEFFICIENTS BASED ON 20% DROOP RANGE SPRINGPART | PRESSURE ina Presse Puig Bo NUMBER AND COLOR | SETTING, Pig Pei an. Pieter, | 200 gor | coo cae | Te” @17) | 1000 Gas) | 1600 eay" | 2000 creep" | 2280 (eRyT Tomanisemss | mo (38) | coos Try Tom aM D058 O28 one ieisanayig Siar | S00 Bas) 5.1 ns Broa 103 8 Ter ose Fan 1D Fg ED By otESreitans Na eR Bulletin 71.1:1301 Innes | of d ‘rw Es Baviess sea) cae Bavieseaea Figure 3. 1301 Series Binenaions NACE Compliance Optional materials are available for applications handling sour gases, These constructions comply ‘with the recommendations of National Association of Corrosive Engineers (NACE) MRO175. ‘The manufacturing processes and materials used by Fisher Controls assure that all products specified for sour gas service comply with the chemical and physical requirements of NACE standard MRO175. Sem) 350889), 338 858) FET a 5 Gq TBE) m8) Mesraim ae) 168 G28) Lisa) 60,185) essa Ordering Information Use the Specifications section on pages 2 and 3 to complete the Ordering Guide on page 8. Specify the desired selection wherever there is a choice to be made, Provide your sales office with this information ‘when ordering the regulator. Bulletin 71.1:1301 Ordering Guide Type (Select One) Gaskets (Select One) 12018: CINeoprene cia os uoreslastomer (FIM) 1 10to 75 psig (0,69 to 5,17 bar} 0 S0to 150 psig (3.45 to 10.3 bar)” 1 Ethyleneprepyiene (EPDM) 100 to 225 psig (6.800 15,5 bar)" Replacement Parts Kit (Optional) 13016: Yes, send one replacement parts kit to match this order. 5 200 to 500 psig (13,8 to 34,5 bar)" Construction Materials (Select One) Cera GM Stainless ster” Specification Workshest Application: Valve Disk (Select One) Specs Nyon the Ste a Spires Eu Typo OO Specie Sraty ‘To order this product, complete this page or Temperatures pque Qvenvessule Piclediioa? empleo te Spectiction Wonthest and forward te Does the appication Require Cverressure Protection? ‘your sales office OYes | No ithe constuction yeu ned ls nat fated on is Pressure ce poe, coat yur focal als of Mexia et Pressure —_________ Telecate your al ealee ofc log ont: DifronalPresaire. | sro ereteonprocess comfeguatrs. Sabesuues Maximum Fw Fisher Regulators Quick Order Gude Revurany Requirements: Seer See manor qa a TT Cem [10% 1) 20% 2 40% 7 [Sigel Certain Slced Pots Cana jar Construction Material Requirements (If know): Praably the rodverg oes dared by he cngonen he Aeon ping ore red cost Industrial Regulators ‘Natural Gas Technologies Industriavigh Purity USA Hoadquerts USA- Heaters Tesco Mekiney,Towas 75050 USA Mekinney, Texas 75080 Elk River, Minesora 5320 USA Tol, 1800558 5356 Tel rapa seese5 Ta rea.24ra28 Ouisae US. 1869.29.41 Sins U & te 208-4201 Selmsdr, Gemmany 23028 dnaPoctic Ti 149 0) 38828 310 a Sirgepcre, Singopers 125401 “ol 88.21.5800 7887 Tel eS OTT EM Eurepe Europe Enloona, tly 40013, Bologna, ay 0012 Tot 30 081 4150611 Tel 20051 410611 Galan, Fterce 23320 Tel #33(0)2 8 3947 00 For further information vst wv emersongrocoss comirequatrs ‘Tha Eno go is adr ed eres orton cess Manet The coer heaton a prasad x Hematon zupce ons hie lt hase oes Hi aco thay ae ot ob cond as mana (eatees opocer inp opudng ho rate crsttoe Sabato er at ean’ ssa hs gto 9 pete deere pecteaene ab oa a ae wtb eden. sn Paces Menge dst sine esprit rhe setn us mnie fay ruscsdaramr seat ora soy sik Pe uetae tk fron Ebene Claw eh s EMERSON For Conlon he, 157,208 Al itt Raced Process Management

You might also like