Literature Study Notes
Literature Study Notes
I. Floor Areas: Required floor areas measured at main or first floor and not including open
porches, breezeway, garage or carports:
1
III. Utility Room:
a. Utility room shall be required in basementless dwellings.
b. A combination kitchen and utility room may be approved with a minimum area of
one hundred eighty (180) square feet, provided the heating unit be installed in a
closet constructed of one-hour fire-resistant material, with sufficient clearance for
maintenance and repairs and with adequate ventilation facilities.
IV. Additional Rooms: Additional habitable rooms require a minimum floor area of one
hundred (100) square feet each.
Generally, drawing or living room is the biggest room of the building so it can be utilized
for some ceremonial function in the house.
Standard size of drawing room may range from: 4200mm (14ft) X 4800 mm (16ft) to
5400mm (18ft) X 7200mm (24ft)
2. Size of Bedrooms:
Bedrooms should be so located that they are well ventilated and at the same time
provide privacy. Generally, they should be located on the sides of the building so that at
least one wall is exposed for good ventilation and lighting.
The bedroom should be located on the side of the direction of the prevailing wind. The
minimum window area should be 1:10th of the floor area.
In bedrooms 9.5 cubic meter per adult and 5.5cubic meter per child space should be
available and suitable allowance should be made for furniture.
Standard size of bedrooms may range from: 3000mm (10ft) X 3600mm (12ft) to 4200mm
(14ft) X 4800mm (16ft)
Standard size of guest rooms may be: 3000mm (10ft) X 3600mm (12ft)
2
4. Size of Office Room:
Office rooms should be on one side of front verandah, disconnected from other rooms.
Sometimes an office room serves the purpose of guest room and vice versa.
Standard size of office room may be: 3000mm (10ft) X 3600mm (12ft)
Size of Dining Room may range from: 3600mm (12ft) X 4200mm (14ft) to 4200mm (14ft)
X4800mm (16ft)
6. Size of Kitchen:
The kitchen should be provided in rear corner of the building but NE corner is the best. It
should be connected with dining room and should have one approach from outside also.
If possible, the kitchen should be so located that sun light should come in the morning
hours, when it is used most.
It should have windows for good ventilation and chimney for smoke escape. The window
space should be min. of 15% of floor area.
Sink should be provided for washing and sufficient number of shelves should also be
provided. Sometimes storeroom and kitchen are combined together, if less space is
available.
Standard size of kitchen rooms may range from: 2500mm (8ft) X 3900mm (13ft) to
3000mm (10ft) X 3600mm (12ft)
7. Store Room:
Store rooms should be located near the kitchen and should have sufficient number of
racks.
Standard size of store room may range from: 2500mm (8ft) X 2500mm (8ft) to 3000mm
(10ft) X 3000mm (10ft)
8. Pantry:
Pantry is a small room adjacent to dining room for keeping cooked food. It should have
sufficient numbers of cup-boards and shelves. For ordinary building, kitchen serves the
purpose of pantry.
3
9. Size of Verandah:
The best location for verandah is south and west. If the frontage of the building is east
then they are located in east also. The verandah also serves the purpose of a waiting
room. It segregates the private apartment from the entrance area. The veranda should
shade the walls of the building during greater part of the day. For this it is necessary that
it must not have openings of a height greater than 2:3rd of the floor width. Each house
should have one front and rear verandah. If space doesn’t permit, the rear verandah can
be omitted. Verandah have width ranging from 1800mm (6ft) to 3000mm (10ft) Verandah
opening should always have a chajja projection for protection from sunlight and
rainwater.
It is not attached to the bedrooms, the bath and WC should be provided in the rear of the
building separately so that the two can be used at a time. Good ventilation should be
provided for the bath and WC.
There should be two windows in the bathroom. One for ventilation at a height of 2000mm
above outside ground level and another at the usual low level with frosted glass shutters
for admitting light and maintaining privacy. Sometimes ceiling height is kept low
(2100mm or 7ft) and upper space is used for storage purposes
The plinth or any part of a building or outhouse shall be so located with respect to
average road level from site so that adequate drainage of the site is assured but at a
not height less than 45 cm.
II. Interior Courtyards, Covered Parking Spaces and Garages
These shall be raised at least 15 cm. above the surrounding ground level and shall
satisfactorily drained.
III. Habitable Rooms Size and Width
4
Table: Minimum Size and Width of Different Components of Residential Premises
Width No Width No
restriction restriction
5
8 Projections Permitted within the Permitted within
setbacks the
upto 0.75 m. width setbacks upto 0.75 m.
width
Length 5.40 m.
Height 2.40 m.
References:
1. https://mohua.gov.in/upload/uploadfiles/files/Chap-4.pdf
2. https://codelibrary.amlegal.com/codes/northbarringtonil/latest/northbarrington_il/0-0-0-3699
3. https://theconstructor.org/building/size-room-location-building/13269/
4. https://thespaceplace.net/space-planning-how-much-space-do-you-really-need/