Ametek 117416-03
Ametek 117416-03
Tom Starek
AMETEK DFS
100 East Erie St
Kent, OH 44240
330.677.3731
[email protected]
Allied Electronics
Created for Danee Lackey
Table of Contents
DISCHARGE
"D2"
Ø5.88
[Ø149.4]
INLET
"D1"
Ø2.60
[Ø66.0]
MOTOR VENTING 45°
26° Ø.17
[Ø4.3] HOLE THRU,
CL LOCATED AS SHOWN ON A
Ø6.40 1.04 "A"
SPEED CONTROL/ 33° [Ø162.6] BOLT CIRCLE [26.4]
90°
CALIBRATION 1.00 3.31 (2X)
[25.4] [84.1] Ø.17
MOTOR 3X [Ø4.3] HOLES THRU,
VENTING LOCATED AS SHOWN ON A
49° 4.66 Ø6.50 BOLT CIRCLE
[118.4] "L" [Ø165.10]
ACCESS TO
SPEED CONTROL/
CALIBRATION
4.00
2.79 [101.6]
[70.9]
Notes:
• Temperature: Working Air: 0°C to 45°C , Ambient Air: 0°C to 45°C, Storage: -40°C to 85°C.
• When used as a vacuum, the blower performance might be less then shown herein, depending on the operating point.
• Weight = 6 lb / 2.2 Kg
Potentiometer Adjustment (Potent. Adjust.) - The specified supply voltage is applied and the speed is set by adjusting a potentiometer on the side of the
blower.
Analog Speed Command (Anlg. Spd. Cmd.) - Blower speed is proportional to an analog speed command signal. The range over which the speed command
signal operates can be calibrated within 0-10V by adjusting the sensitivity potentiometer accessed through the side of the blower. The sensitivity adjustment
is also useful for precisely calibrating a group of blowers to the same speed for a given operating point and command signal voltage.
Tachometer Output - All of the models listed above come equipped with a tachometer output: a square wave output that is proportional to blower speed.
The frequency of the tachometer output signal is 2x the blower’s rotational frequency.
1 MECH.
TACH-OUTPUT
REVOLUTION
+Vin
12V
COM
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS A 117
627 Lake Street, Kent OH 44240
____ PRECISION MOTION CONTROL
USA: +1 215-256-6601 - Europe: +44 (0) 845 366 9664 - Asia: +86 21 5763 1258
www.ametektip.com
Low Voltage Brushless DC Blowers
5.7" (145mm) BLDC Bypass Blower
24 VDC Input, High Flow System
Typical Performance
150403, 150434
150404, 150435
Pressure (inch H2O)
150405, 150436
Pressure (mbar)
Flow (CFM)
27
24
Current (A)
21
19
16
13
10
7
Speed (RPM)
700
Power Demand
575
(Watts)
450
325
200
Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS A 218
627 Lake Street, Kent OH 44240
____ PRECISION MOTION CONTROL
USA: +1 215-256-6601 - Europe: +44 (0) 845 366 9664 - Asia: +86 21 5763 1258
www.ametektip.com
Low Voltage Brushless DC Blowers
5.7" (145mm) BLDC Bypass Blower
48 VDC Input, High Flow System
3.74
INCH [95.0]
[MM]
DISCHARGE
"D 2"
Ø5.88
[Ø149.4]
INLET
Ø2.60 "D1"
[Ø66.0]
MOTOR VENTING
2.40
[61.0]
1
2 3 45°
4 5 Ø.17 HOLE THRU,
CL [Ø4.3]
SPEED CONTROL/ LOCATED AS SHOWN ON A
CALIBRATION Ø6.40 BOLT CIRCLE
[Ø162.6] 1.04 "A"
[26.4]
26° 33° 90°
49° 1.00 3.2 (2X)
[25.4] [81]
MOTOR 3X Ø.17 HOLES THRU,
"A" VENTING
[Ø4.3]
LOCATED AS SHOWN ON A
4.66 "L" Ø6.50 BOLT CIRCLE
[118.4] [Ø165.10]
ACCESS TO
SPEED CONTROL/
CALIBRATION
1.38
[35.1]
2.79
[70.9]
3.29
[83.6]
VIEW "A"
Notes:
• Temperature: Working Air: 0°C to 45°C , Ambient Air: 0°C to 45°C, Storage: -40°C to 85°C.
• When used as a vacuum, the blower performance might be less then shown herein, depending on the operating point.
• Weight = 6 lb / 2.2 Kg
Potentiometer Adjustment (Potent. Adjust.) - The specified supply voltage is applied and the speed is set by adjusting a potentiometer on the side
of the blower.
Analog Speed Command (Anlg. Spd. Cmd.) - Blower speed is proportional to an analog speed command signal. The range over which the speed
command signal operates can be calibrated within 0-10V by adjusting the sensitivity potentiometer accessed through the side of the blower. The
sensitivity adjustment is also useful for precisely calibrating a group of blowers to the same speed for a given operating point and command signal
voltage.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS A 325
627 Lake Street, Kent OH 44240
____ PRECISION MOTION CONTROL
USA: +1 215-256-6601 - Europe: +44 (0) 845 366 9664 - Asia: +86 21 5763 1258
www.ametektip.com
Low Voltage Brushless DC Blowers
5.7" (145mm) BLDC Bypass Blower
48 VDC Input, High Flow System
Typical Performance
150414, 150444
150415, 150445
150416, 150446
Pressure (inch H2O)
Pressure (mbar)
Flow (CFM)
11
Current (A)
5
Speed (RPM)
500
Power Demand
450
(Watts)
400
350
300
250
Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS A 426
627 Lake Street, Kent OH 44240
____ PRECISION MOTION CONTROL
USA: +1 215-256-6601 - Europe: +44 (0) 845 366 9664 - Asia: +86 21 5763 1258
www.ametektip.com
High Voltage Brushless DC Blowers
5.7" (145mm) BLDC Thru Flow Blower
250 Watt, 120 Volt Standard Flow
INCH
ISOLATED SPEED
CONTROL
{ HIGH
{
NEUTRAL AC INPUT
VOLTAGE
{
NEUTRAL AC INPUT
VOLTAGE
0-10V DC LINE 108V-132V LINE
[MM] LOW 108V-132V
INPUT REQUIRED PIN NOT USED PIN NOT USED
ACCESS TO
SPEED CONTROL/ DETAIL "E" DETAIL "M"
CALIBRATION (ELECTRICAL) (MECHANICAL)
1.15 POWER/CONTROL CONNECTION DETAILS
[29.2]
ACCESS TO PRESSURE TAP
CL POST HEADER OPTION
Ø1.25 3.74
29° [Ø31.8] [95.0]
DISCHARGE
66°
CL
SPEED CONTROL/ INLET Ø5.90 2.37
CALIBRATION [60.2]
[Ø150.0]
MAX. 3X 90°
Ø1.25
[Ø31.8]
1.43 .75
3X Ø.23 HOLES [36.3] [19.1] 33°
[Ø5.8] "l"
.37 45°
[9.4] DEEP MINIMUM "L" EARTH GROUND
EQUALLY SPACED AS SHOWN ON Ø.17 HOLE THRU,
A Ø4.00 BOLT CIRCLE [Ø4.3]
[Ø101.6] LOCATED AS SHOWN ON
Ø6.40 BOLT CIRCLE
[Ø162.6]
Notes:
• Input Voltage Range: 108-132 Volts AC RMS, 50/60 Hz., Single Phase.
• Input Current: 5 amps AC RMS
• Operating Temperature (Ambient Air and Working Air): 0˚ C to 50˚ C
• Storage Temperature: -40˚ C to 85˚ C
• Dielectric Testing: 1500 Volts AC RMS 60 Hz applied for one second between input pins and ground, 3mA leakage maximum.
• Speed Control: E (Electrical) Pulse Width Modification or Analog input voltage (user supplied), 0 to 10 Volts DC,10mA maximum, 3 to 15 Volts DC. Access to sensitivity adjustment for 0 to 10 VDC
speed control. (Ref. pin connection).
M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access for speed adjustment located in blower
housing.
• Approximate Weight: 6 Lbs. / 2.2 Kg.
• Regulatory Agency Certification: Underwriters Laboratories, Inc. qualified per UL507 under File E-94403. Canadian Standards Association qualified per C22.2#113 under File LR 43448.
• Miscellaneous: Intake and exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and exhaust must be free of grease, oil and foreign particles. Amp housing 640250-6
w/SL-156 contacts (suppied by customer) mates with post header assembly.
Mating harness available upon request.
Optional IntelliGenTM controller available for customized performance and features including: tachometer output card; Universal AC input (100V-240V).
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS B51
627 Lake Street, Kent OH 44240
____ PRECISION MOTION CONTROL
USA: +1 215-256-6601 - Europe: +44 (0) 845 366 9664 - Asia: +86 21 5763 1258
www.ametektip.com
High Voltage Brushless DC Blowers
5.7" (145mm) BLDC Thru Flow Blower
250 Watt, 120 Volt Standard Flow
Typical Performance
Flow (m3/hr)
116626, 116629
116627, 116630
Pressure (inch H2O)
Pressure (mbar)
Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)
Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS B62
627 Lake Street, Kent OH 44240
____ PRECISION MOTION CONTROL
USA: +1 215-256-6601 - Europe: +44 (0) 845 366 9664 - Asia: +86 21 5763 1258
www.ametektip.com
High Voltage Brushless DC Blowers
5.7" (145mm) BLDC Bypass Blower
250 Watt, 120 Volt Standard Flow
INCH
[MM]
INLET 2.37
[60.2]
Ø5.90 3X 90°
Ø1.25 [Ø150.0]
[Ø31.8] Ø.17 HOLES THRU,
MAX. 4X [Ø4.3]
LOCATED AS SHOWN ON
37° Ø6.50
NC
R EA S
[Ø165.10]BOLT CIRCLE
E
I
CL
SPEED CONTROL/ EARTH GROUND
Ø1.3 MAX. CALIBRATION 1.04 .75 Ø.17
[Ø33.0] [26.4] [19.1] [Ø4.3] HOLE THRU,
MOTOR COOLING LOCATED AS SHOWN ON 33°
ACCESS TO SPEED CONTROL/ Ø6.40 45°
INLET CALIBRATION [Ø162.6]BOLT CIRCLE
"I"
"L"
{
NEUTRAL AC INPUT
VOLTAGE
{
NEUTRAL AC INPUT
VOLTAGE
LINE 108V-132V LINE 108V-132V
Notes:
• Input Voltage Range: 108-132 Volts AC RMS, 50/60 Hz., Single Phase.
• Input Current: 5 amps AC RMS
• Operating Temperature (Ambient Air and Working Air): 0˚ C to 50˚ C
• Storage Temperature: -40˚ C to 85˚ C
• Dielectric Testing: 1500 Volts AC RMS 60 Hz applied for one second between input pins and ground, 3mA leakage maximum.
• Speed Control: E (Electrical) Pulse Width Modification or Analog input voltage (user supplied), 0 to 10 Volts DC,10mA maximum, 3 to 15 Volts DC. Access to sensitivity adjustment for 0 to 10 VDC
speed control. (Ref. pin connection).
M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access for speed adjustment located in blower
housing.
• Approximate Weight: 6 Lbs. / 2.2 Kg.
• Regulatory Agency Certification: Underwriters Laboratories, Inc. qualified per UL507 under File E-94403. Canadian Standards Association qualified per C22.2#113 under File LR 43448.
• Miscellaneous: Intake and exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and exhaust must be free of grease, oil and foreign particles. Amp housing 640250-6
w/SL-156 contacts (suppied by customer) mates with post header assembly.
Mating harness available upon request.
Optional IntelliGenTM controller available for customized performance and features including: tachometer output card; Universal AC input (100V-240V).
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS B77
627 Lake Street, Kent OH 44240
____ PRECISION MOTION CONTROL
USA: +1 215-256-6601 - Europe: +44 (0) 845 366 9664 - Asia: +86 21 5763 1258
www.ametektip.com
High Voltage Brushless DC Blowers
5.7" (145mm) BLDC Bypass Blower
250 Watt, 120 Volt Standard Flow
Typical Performance
Flow (m3/hr)
116634, 116640
116633, 116639
Pressure (inch H2O)
116632, 116638
Pressure (mbar)
Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)
Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS B88
627 Lake Street, Kent OH 44240
____ PRECISION MOTION CONTROL
USA: +1 215-256-6601 - Europe: +44 (0) 845 366 9664 - Asia: +86 21 5763 1258
www.ametektip.com
High Voltage Brushless DC Blowers
5.7" (145mm) BLDC Bypass Blower
250 Watt, 120 Volt High Flow
INCH
[MM]
INLET 2.12
[53.8]
3X 90°
Ø1.75 5.90
[Ø44.5] [ 150.0]
MAX. Ø.17 HOLES THRU,
4X[Ø4.3]
LOCATED AS SHOWN ON
37° Ø6.50 BOLT CIRCLE
NC
R EAS [Ø165.10]
E
I 45°
EARTH GROUND
Ø.17
CL [Ø4.3] HOLE THRU,
SPEED CONTROL/ LOCATED AS SHOWN ON
Ø1.3 MAX. CALIBRATION 1.04 .75 Ø6.40 BOLT CIRCLE
[Ø33.0] [26.4] [19.1] [Ø162.6]
MOTOR COOLING 33°
INLET ACCESS TO SPEED CONTROL/
CALIBRATION
NEUTRAL
{ AC INPUT
VOLTAGE
NEUTRAL
{ AC INPUT
VOLTAGE
"I" LINE 108V-132V LINE 108V-132V
Notes:
• Input Voltage Range: 108-132 Volts AC RMS, 50/60 Hz., Single Phase.
• Input Current: 5 amps AC RMS
• Operating Temperature (Ambient Air and Working Air): 0˚ C to 50˚ C
• Storage Temperature: -40˚ C to 85˚ C
• Dielectric Testing: 1500 Volts AC RMS 60 Hz applied for one second between input pins and ground, 3mA leakage maximum.
• Speed Control: E (Electrical) Pulse Width Modification or Analog input voltage (user supplied), 0 to 10 Volts DC,10mA maximum, 3 to 15 Volts DC. Access to sensitivity adjustment for 0 to 10 VDC
speed control. (Ref. pin connection).
M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access for speed adjustment located in blower
housing.
• Approximate Weight: 6 Lbs. / 2.2 Kg.
• Regulatory Agency Certification: Underwriters Laboratories, Inc. qualified per UL507 under File E-94403. Canadian Standards Association qualified per C22.2#113 under File LR 43448.
• Miscellaneous: Intake and exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and exhaust must be free of grease, oil and foreign particles. Amp housing 640250-6
w/SL-156 contacts (suppied by customer) mates with post header assembly.
Mating harness available upon request.
Optional IntelliGenTM controller available for customized performance and features including: tachometer output card; Universal AC input (100V-240V).
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS B95
627 Lake Street, Kent OH 44240
____ PRECISION MOTION CONTROL
USA: +1 215-256-6601 - Europe: +44 (0) 845 366 9664 - Asia: +86 21 5763 1258
www.ametektip.com
High Voltage Brushless DC Blowers
5.7" (145mm) BLDC Bypass Blower
250 Watt, 120 Volt High Flow
Typical Performance
Flow (m3/hr)
116637, 116643
116636, 116642
Pressure (inch H2O)
116635, 116641
Pressure (mbar)
Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)
Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS B106
627 Lake Street, Kent OH 44240
____ PRECISION MOTION CONTROL
USA: +1 215-256-6601 - Europe: +44 (0) 845 366 9664 - Asia: +86 21 5763 1258
www.ametektip.com
High Voltage Brushless DC Blowers
5.7" (145mm) BLDC Thru Flow Blower
250 Watt, 120 Volt High Flow
SEE DETAIL "E" OR "M"
ISOLATED SPEED
CONTROL
{ HIGH NEUTRAL
LINE
{ AC INPUT
VOLTAGE
{
NEUTRAL AC INPUT
VOLTAGE
0-10V DC LOW 108V-132V LINE 108V-132V
INCH INPUT REQUIRED PIN NOT USED
[MM] PIN NOT USED
Ø1.75
66° [Ø44.5]
C
L
SPEED CONTROL/ INLET 2.12
CALIBRATION [53.8]
Ø5.90
[Ø150.0] 3X 90°
Ø1.75
[Ø44.5] MAX.
1.43 .75
Ø.23 HOLES [36.3] [19.1] 33°
3X [Ø5.8]
.37 DEEP MINIMUM "l" 45°
[9.4]
EQUALLY SPACED AS SHOWN ON "L" EARTH GROUND
Ø.17 HOLE THRU,
Ø4.00 BOLT CIRCLE
A [Ø101.6] [Ø4.3]
LOCATED AS SHOWN ON
Ø6.40 BOLT CIRCLE
[Ø162.6]
Notes:
• Input Voltage Range: 108-132 Volts AC RMS, 50/60 Hz., Single Phase.
• Input Current: 5 amps AC RMS
• Operating Temperature (Ambient Air and Working Air): 0˚ C to 50˚ C
• Storage Temperature: -40˚ C to 85˚ C
• Dielectric Testing: 1500 Volts AC RMS 60 Hz applied for one second between input pins and ground, 3mA leakage maximum.
• Speed Control: E (Electrical) Pulse Width Modification or Analog input voltage (user supplied), 0 to 10 Volts DC,10mA maximum, 3 to 15 Volts DC. Access to sensitivity adjustment for 0 to 10 VDC
speed control. (Ref. pin connection).
M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access for speed adjustment located in blower
housing.
• Approximate Weight: 6 Lbs. / 2.2 Kg.
• Regulatory Agency Certification: Underwriters Laboratories, Inc. qualified per UL507 under File E-94403. Canadian Standards Association qualified per C22.2#113 under File LR 43448.
• Miscellaneous: Intake and exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and exhaust must be free of grease, oil and foreign particles. Amp housing 640250-6
w/SL-156 contacts (suppied by customer) mates with post header assembly.
Mating harness available upon request.
Optional IntelliGenTM controller available for customized performance and features including: tachometer output card; Universal AC input (100V-240V).
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS B113
627 Lake Street, Kent OH 44240
____ PRECISION MOTION CONTROL
USA: +1 215-256-6601 - Europe: +44 (0) 845 366 9664 - Asia: +86 21 5763 1258
www.ametektip.com
High Voltage Brushless DC Blowers
5.7" (145mm) BLDC Thru Flow Blower
250 Watt, 120 Volt High Flow
Typical Performance
Flow (m3/hr)
116644, 116647
116645, 116648
Pressure (inch H2O)
Pressure (mbar)
Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)
Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS B124
627 Lake Street, Kent OH 44240
____ PRECISION MOTION CONTROL
USA: +1 215-256-6601 - Europe: +44 (0) 845 366 9664 - Asia: +86 21 5763 1258
www.ametektip.com
High Voltage Brushless DC Blowers
5.7" (145mm) BLDC Bypass Blower
400 Watt, 240 Volt High Flow
PRESSURE TAP
43° DISCHARGE OPTION
MOTOR COOLING 3.74
DISCHARGE [95.0]
E
I
SPEED CONTROL/ 3X 90°
Ø1.75
CALIBRATION [Ø44.5] Ø5.90
[Ø150.0]
MAX. 4X Ø.17 HOLES THRU,
[Ø4.3]
2.38 LOCATED AS SHOWN ON
[60.5] Ø6.50 BOLT CIRCLE
[Ø165.10]
Ø1.3 MAX.
[Ø33.0] 1.04 .75 33°
[26.4] [19.1]
MOTOR COOLING
INLET 45°
ACCESS TO SPEED CONTROL/ "l"
CALIBRATION EARTH GROUND
Ø.17
"L" [Ø4.3] HOLE THRU,
LOCATED AS SHOWN ON
Ø6.40
[Ø162.6]BOLT CIRCLE
5 4 3 2 1 5 4 3 2 1
}
LOW ISOLATED SPEED NOT USED
CONTROL
0-10V. D.C.
HIGH INPUT REQUIRED NOT USED
GROUND GROUND
AC INPUT VOLTAGE AC INPUT VOLTAGE
216V-264V 216V-264V
DETAIL "E" DETAIL "M"
(ELECTRICAL) (MECHANICAL)
POWER/CONTROL CONNECTION DETAILS
Notes:
• Input Voltage Range: 216-264 Volts AC RMS, 50/60 Hz., Single Phase.
• Input Current: 5 amps AC RMS
• Operating Temperature (Ambient Air and Working Air): 0˚ C to 50˚ C
• Storage Temperature: -40˚ C to 85˚ C
• Dielectric Testing: 1800 Volts AC RMS 60 Hz applied for one second between input pins and ground, 3mA leakage maximum.
• Speed Control: E (Electrical) Pulse Width Modification or Analog input voltage (user supplied), 0 to 10 Volts DC, 10mA maximum, 3 to 15 Volts DC. Access to sensitivity adjustment for 0 to 10 VDC
speed control. (Ref. pin connection).
M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specific speed. Access for speed adjustment located in blower
housing.
• Approximate Weight: 6 Lbs. / 2.2 Kg.
• Regulatory Agency Certification: Underwriters Laboratories, Inc. qualified per UL507 under File E-94403. Canadian Standards Association qualified per C22.2#113 under File LR 43448.
• Miscellaneous: Intake and exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and exhaust must be free of grease, oil and foreign particles. Amp housing 350809-1 with
sockets for 18 awg lead wire (suppied by customer) mates with post header assembly.
Mating harness available upon request.
Optional IntelliGenTM controller available for customized performance and features including; tachometer output card; Universal AC input (100V-240V).
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS B13
13
627 Lake Street, Kent OH 44240
____ PRECISION MOTION CONTROL
USA: +1 215-256-6601 - Europe: +44 (0) 845 366 9664 - Asia: +86 21 5763 1258
www.ametektip.com
High Voltage Brushless DC Blowers
5.7" (145mm) BLDC Bypass Blower
400 Watt, 240 Volt High Flow
Typical Performance
Flow (m3/hr)
117637, 117643
Pressure (inch H2O)
Pressure (mbar)
117636, 117642
117635, 117641
Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)
Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS B14
14
627 Lake Street, Kent OH 44240
____ PRECISION MOTION CONTROL
USA: +1 215-256-6601 - Europe: +44 (0) 845 366 9664 - Asia: +86 21 5763 1258
www.ametektip.com
High Voltage Brushless DC Blowers
5.7" (145mm) BLDC Bypass Blower
1200 Watt, 240 Volt Standard Flow - IntelliGen (TM)
PRESSURE TAP
DISCHARGE OPTION
3.74
[95.0]
Ø1.25
[Ø31.8]
INCH
[MM] 2.37
INLET [60.2]
3X 90°
Ø1.25
[Ø31.8] Ø5.90
[Ø150.0]
Ø2.60 MAX.
[Ø66.0] MAX. Ø.17 HOLES THRU,
4X [Ø4.3]
2.40 MOTOR COOLING
INLET LOCATED AS SHOWN ON
12 [61.0] Ø6.50
34
5 [Ø165.10] BOLT CIRCLE
CL
SPEED CONTROL/
CALIBRATION
MOTOR COOLING 1.04 .75
[19.1] 33°
DISCHARGE [26.4]
49° 26° 45°
SEE DETAIL "E" & "M" 2.12 EARTH GROUND
[53.8] Ø.17 HOLE THRU,
6.87 [Ø4.3]
[174.5] LOCATED AS SHOWN ON
Ø6.40
[Ø162.6] BOLT CIRCLE
}
LOW ISOLATED SPEED NOT USED
CONTROL
0-10V. D.C.
1 HIGH INPUT REQUIRED 1 NOT USED
R EAS
2 GROUND 2 GROUND
NC
E
I
Notes:
• Input Voltage Range: 208-264 Volts AC RMS, 50/60 Hz., Single Phase, maximum running current 10 Amps RMS.
Note: Although this unit contains a lock-out feature that detects low voltage conditions, the electronics should not be operated continuously below the input voltage range listed above.
• Operating Temperature (Ambient Air and Working Air): 0˚ C to 50˚ C
• Storage Temperature: -40˚ C to 85˚ C (Internal electronic controller is thermally protected).
• Dielectric Testing: 1800 Volts AC RMS 60 Hz applied for one second between input pins and ground, 3mA leakage maximum.
• Isolated Speed Control:
Analog Input Voltage Range: 2 to +10 VDC nominal (+13.5 VDC maximum).
Digital Pulse Input: 400 Hz to 20 KHz, 0 to +10 volt pulse nominal, minimum duty cycle 10%, 0 to +13.5 volt maximum.
Note: Setting of onboard potentiometer can effect control voltage range and maximum speed can be attained before reaching 10 VDC
• Speed Control Input Current: 5 mA to 20mA at 10 Volts input with multi-turn potentiometer set to minimum resistance (fully clockwise).
• Speed Control Drift with Temperature:
Analog Mode: Typ. +-4% from nominal speed at +23 C.
Digital or Direct Mode: Typ. +-4% from nominal speed at 23 C.
• Approximate Weight: 6 Lbs. / 2.2 Kg.
• Regulatory Agency Certification: Underwriters Laboratories, Inc. qualified per UL507 under File E-94403. Canadian Standard Association qualified per C22.2#113 under File LR 43448.
• Miscellaneous: Intake and exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and exhaust must be free of grease, oil and foreign particles. Amp housing 350809-1 with
male pins on 16 awg lead wire (suppied by customer) mates with post header assembly.
Mating harness available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS B15
19
627 Lake Street, Kent OH 44240
____ PRECISION MOTION CONTROL
USA: +1 215-256-6601 - Europe: +44 (0) 845 366 9664 - Asia: +86 21 5763 1258
www.ametektip.com
High Voltage Brushless DC Blowers
5.7" (145mm) BLDC Bypass Blower
1200 Watt, 240 Volt Standard Flow - IntelliGen (TM)
Typical Performance
Flow (m3/hr)
117416, 117415
Pressure (inch H2O)
Pressure (mbar)
Flow (CFM)
Current (A)
Speed (RPM)
Power Demand
(Watts)
Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.
INSTALLATION:
• The blower must be secured using mounting tabs, prior to applying power. This is a high speed device with rapid acceleration.
• Connections:
All of the Windjammer IntelliGen™ series blowers have a standard 5 pin connector.
A mating connector with leads is supplied with single pack units only.
Negative pressure applications will exhibit reduced performance.
Exhaust air must be prohibited from being recycled to inlet air.
If blower is to be cycled frequently, the DC speed command should be used.
For use in industrial applications, use AMETEK Technical & Industrial Products cooling air filters.
Note: Utilize AMETEK external EMC filter accessory to meet EN61000-4-6 requirement.
• Option Circuit Connections: Please consult with AMETEK for connection details for all options and custom circuitry.
• Utilizes AMETEK’s IntelliGen™ control electronics.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS B16
20
627 Lake Street, Kent OH 44240
____ PRECISION MOTION CONTROL
USA: +1 215-256-6601 - Europe: +44 (0) 845 366 9664 - Asia: +86 21 5763 1258
www.ametektip.com
High Voltage Brushless DC Blowers
5.7" (145mm) BLDC Bypass Blower
1200 Watt, 240 Volt High Flow - IntelliGen (TM)
PRESSURE TAP
DISCHARGE OPTION
3.74
[95.0]
Ø1.75
[Ø44.5]
INCH
[MM] INLET 2.12
[53.8]
3X 90°
Ø1.75
[Ø44.5] Ø5.90
[Ø150.0]
Ø2.60 MAX. 4X Ø.17 HOLES THRU,
[Ø66.0]MAX. [Ø4.3]
2.40 MOTOR COOLING LOCATED AS SHOWN ON
[61.0] INLET Ø6.50
1
2
3
4
[Ø165.10] BOLT CIRCLE
CL 5
SPEED CONTROL/
CALIBRATION
MOTOR COOLING 1.04
"B" 33°
DISCHARGE [26.4]
49° 26° 45°
SEE DETAIL "E" & "M" "A" EARTH GROUND
Ø.17 HOLE THRU,
[Ø4.3]
"L"
LOCATED AS SHOWN ON
Ø6.40
[Ø162.6]BOLT CIRCLE
}
LOW ISOLATED SPEED NOT USED
CONTROL
0-10V. D.C.
1 HIGH INPUT REQUIRED 1 NOT USED
2 GROUND 2 GROUND
NC
R EA S
3 AC INPUT VOLTAGE 3 AC INPUT VOLTAGE
E
I
208V-264V 208V-264V
4 4
5 5
ACCESS TO SPEED CONTROL/
CALIBRATION
DETAIL "E" DETAIL "M"
(ELECTRICAL) (MECHANICAL)
POWER/CONTROL CONNECTION DETAILS
Notes:
• Input Voltage Range: 216-264 Volts AC RMS, 50/60 Hz., Single Phase, maximum running current 10 Amps RMS.
Note: Although this unit contains a lock-out feature that detects low voltage conditions, the electronics should not be operated continuously below the input voltage range listed above.
• Operating Temperature (Ambient Air and Working Air): 0˚ C to 50˚ C
• Storage Temperature: -40˚ C to 85˚ C (Internal electronic controller is thermally protected).
• Dielectric Testing: 1800 Volts AC RMS 60 Hz applied for one second between input pins and ground, 3mA leakage maximum.
• Isolated Speed Control:
Analog Input Voltage Range: 2 to +10 VDC nominal (+13.5 VDC maximum).
Digital Pulse Input: 400 Hz to 20 KHz, 0 to +10 volt pulse nominal, minimum duty cycle 10%, 0 to +13.5 volt maximum.
Note: Setting of onboard potentiometer can effect control voltage range and maximum speed can be attained before reaching 10 VDC
• Speed Control Input Current: 5 mA to 20mA at 10 Volts input with multi-turn potentiometer set to minimum resistance (fully clockwise).
• Speed Control Drift with Temperature:
Analog Mode: Typ. +-4% from nominal speed at +23 C.
Digital or Direct Mode: Typ. +-4% from nominal speed at 23 C.
• Approximate Weight: 6 Lbs. / 2.2 Kg.
• Regulatory Agency Certification: Underwriters Laboratories, Inc. qualified per UL507 under File E-94403. Canadian Standard Association qualified per C22.2#113 under File LR 43448.
• Miscellaneous: Intake and exhaust tubes, all cooling ducts and vents must not be obstructed. Intake and exhaust must be free of grease, oil and foreign particles. Amp housing 350809-1 with
male pins on 16 awg lead wire (suppied by customer) mates with post header assembly.
Mating harness available upon request.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS B17
21
627 Lake Street, Kent OH 44240
____ PRECISION MOTION CONTROL
USA: +1 215-256-6601 - Europe: +44 (0) 845 366 9664 - Asia: +86 21 5763 1258
www.ametektip.com
High Voltage Brushless DC Blowers
5.7" (145mm) BLDC Bypass Blower
1200 Watt, 240 Volt High Flow - IntelliGen (TM)
Typical Performance
Flow (m3/hr)
119151, 119152
119153, 119154
Pressure (inch H2O)
Pressure (mbar)
119163
119155
Flow (CFM)
13
Current (A)
10
Speed (RPM)
Power Demand
(Watts)
Data presented represents blower performance at STANDARD AIR DENSITY, .075 lb/ft3 (29.92” Hg, Sea Level, 68° F)
Vacuum performance available upon request.
INSTALLATION:
• The blower must be secured using mounting tabs, prior to applying power. This is a high speed device with rapid acceleration.
Connections:
• All of the Windjammer IntelliGen™ series blowers have a standard 5 pin connector.
A mating connector with leads is supplied with single pack units only.
Negative pressure applications will exhibit reduced performance.
Exhaust air must be prohibited from being recycled to inlet air.
If blower is to be cycled frequently, the DC speed command should be used.
For use in industrial applications, use AMETEK Technical & Industrial Products cooling air filters.
Note: Utilize AMETEK external EMC filter accessory to meet EN61000-4-6 requirement.
• Option Circuit Connections: Please consult with AMETEK for connection details for all options and custom circuitry.
• Utilizes AMETEK’s IntelliGen™ control electronics.
This document is for informational purposes only and should not be considered as a binding description of the products or their performance in all applications. The performance data on this page depicts
typical performance under controlled laboratory conditions. AMETEK is not responsible for blowers driven beyond factory specified speed, temperature, pressure, flow or without proper alignment. Actual
performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the
right to revise its products without notification. The above characteristics represent standard products. For product designed to meet specific applications, contact AMETEK Technical & Industrial Products
Sales department.
AMETEK TECHNICAL & INDUSTRIAL PRODUCTS B18
22
627 Lake Street, Kent OH 44240
____ PRECISION MOTION CONTROL
USA: +1 215-256-6601 - Europe: +44 (0) 845 366 9664 - Asia: +86 21 5763 1258
www.ametektip.com
AMETEK, Inc.
AMETEK is a leading global manufacturer of electronic instruments and electromechanical devices with
annualized sales of more than $2.5 billion. AMETEK has nearly 11,000 colleagues working at more than
80 manufacturing facilities and more than 60 sales and service centers in the United States and over 30
other countries around the world.
AMETEK supports its customers globally from its manufacturing facilities in Minnesota, New York, North
Carolina, Ohio, Pennsylvania, Italy and China. Our brushless DC motors, blowers, controllers, pumps,
and fans are ideally suited for a wide range of applications, including medical instruments, robotics,
pumps, compressors, office equipment, fans, machine tools, tape drives, or any other precise rotary
motion/air delivery applications.
Technical & Industrial Products’ product line of regenerative blowers for pressure and vacuum
applications services the process, industrial, environmental, waste, and wastewater industrial industry.
Typical applications areas include solution agitation and aeration, pneumatic conveying, part hold-down
and pick up, part blow off, gas and fume extraction, and process gas handling.
AMETEK Technical & Industrial Products supplies the solution for unique performance, mounting,
environmental and agency requirements.