You are on page 1/ 98

Self-Service

Systems
CINEO C4040

Installation Guide
Questions and suggestions

Do you have ...

... any questions or suggestions


regarding this manual?

Please contact the following address


giving the order number of this manual
in your message:

Address:
WINCOR NIXDORF International GmbH
Handbuchredaktion BD PSD 43
D - 33094 Paderborn
Germany

Fax: +49 (0) 52 51 693-62 09

E-mail: [email protected]

... any technical questions or problems?

Please contact your local representative.

CINEO C4040 - Installation Guide 01750203983 B


CINEO C4040

Installation Guide

Edition April 2011


Copyright © Information and trademarks

© WINCOR NIXDORF International GmbH 2011

All rights, including rights of translation


and rights of reproduction by reprinting,
copying or similar methods, even of
parts, are reserved.
Any violations give rise to a claim for
damages.

All rights, including rights created by


patent grants or registration of a utility
model or design, are reserved. Delivery
subject to availability; right of technical
modifications reserved.

All names of hardware and software


products mentioned in this manual are
trade names and/or trademarks of their
respective manufacturers.

This manual was


produced using paper
treated with chlorine-free
bleach.

CINEO C4040 - Installation Guide 01750203983 B


Contents

Introduction ............................................................................................... 1
Symbols used in this manual ...................................................................... 1
Important safety precautions ...................................................................... 2
Installation note ..................................................................................... 2
General safety precautions ................................................................... 2

Planning the Installation .......................................................................... 5


Device dimensions ..................................................................................... 5
CINEO C4040 Frontload ....................................................................... 6
CINEO C4040 Rearload ........................................................................ 7
Dimensions of cable areas .................................................................... 8
frontload with UL safe....................................................................... 8
Installation options of device versions ...................................................... 10
Installation without frame (free-standing) ............................................ 11
Vent .......................................................................................................... 12
Storage if construction work is not yet complete ...................................... 12
Space required for operation and maintenance ....................................... 13
Frontload version ................................................................................. 14
Rearload version ................................................................................. 15
Installation site requirements .................................................................... 16
Load-carrying capacity ........................................................................ 16
Notes on floor mounting ...................................................................... 17
Protection from removal by force in compliance with EN and VdS
guidelines ............................................................................................ 17
Installation frame ...................................................................................... 18
General information ............................................................................. 18
Dimensions of safe attachment points ................................................ 19
Dimensions of cable areas .................................................................. 22
Tear-off sensor ......................................................................................... 25
Drilling diagrams ....................................................................................... 26
Drilling diagram Frontload ................................................................... 27
Drilling diagram Rearload ............................................................... 28
Power and data cables ............................................................................. 29
General ................................................................................................ 29
Cable lead-ins into the safe ................................................................. 30
Cable lead-in into the safe from the side or from the rear ............. 30

01750203983 B CINEO C4040 - Installation Guide I


Contents

Cable lead-in into the safe from below ........................................... 31


Power supply ....................................................................................... 33
Remote status indicator ....................................................................... 33
Transport path requirements .................................................................... 33

Installation ............................................................................................... 41
Removing the packing .............................................................................. 41
Removing the shipping crate .................................................................... 42
General information ............................................................................. 42
Disassembly ........................................................................................ 43
Mounting sets............................................................................................ 44
Mounting set 01750006706 installation frame for UL / CEN L safe .... 44
Mounting set 01750078516 (for UL / CEN L safe) on installation
frame .................................................................................................... 44
Overview of installation types ................................................................... 45
Installation without frame .......................................................................... 45
Mounting the installation frame ............................................................ 46
Mounting the device on the installation frame ..................................... 52
Screwing the device on the installation frame ................................ 52
Installing the power and data cables in the device ......................... 53
General information ........................................................................ 53
Start-up ..................................................................................................... 53
Check power plugs on the power distributor ....................................... 54

Installing the Remote Status Indicator ................................................. 55


Remote status indicator - standard ........................................................... 55
Delivery package ................................................................................. 55
Installation ............................................................................................ 56
Connection to the relay panel for external features............................. 57
Remote status indicator - audio ................................................................ 59
Delivery package ................................................................................. 59
Installation ............................................................................................ 60
Connection to the relay panel for external features............................. 62
Shortening the cables ............................................................................... 64
Adapting the cable length at the relay panel end ................................ 64
Adapting the cable length at the standard remote status indicator
end ....................................................................................................... 64
Adapting the cable length at the remote status indicator (audio) ........ 67

Appendix .................................................................................................. 71

II CINEO C4040 - Installation Guide 01750203983 B


Contents

Check list for installation preparations for self-service systems ............... 71


General information ............................................................................. 72
Preparations ........................................................................................ 72
Construction work........................................................................... 72
Power and data cables ................................................................... 73
Organizational preparations ........................................................... 73
Delivery and installation ................................................................. 74
Flooring materials on the path of transport .................................... 74
Notes concerning installation preparation ........................................... 75
Technical data .......................................................................................... 77
General installation conditions ............................................................ 77
Electrical characteristics of the supply network ............................. 77
Device conditions ........................................................................... 78
Installation specifications ............................................................... 79
Environmental conditions ............................................................... 80
Compliance with standards and certifications .......................................... 82
Standards met ..................................................................................... 82
Conformity ........................................................................................... 82
Notes concerning radio interference suppression and electrical
safety ................................................................................................... 83
Certification for data transmission ....................................................... 83
FCC rules and Canadian Standard ICES - 003 .................................. 83
UL 291, Level 1 (security Container) ................................................... 83
Environmental protection .......................................................................... 84
Environmentally and recycling-friendly product development ............. 84
Saving energy...................................................................................... 84
Disposing of used consumables ......................................................... 84
Labels on plastic case parts ................................................................ 85
Returning, recycling and disposing of used units and
consumables ....................................................................................... 85

01750203983 B CINEO C4040 - Installation Guide III


Contents

IV CINEO C4040 - Installation Guide 01750203983 B


Abbreviations

B D
BSMI Bureau of Standards, DT Data Transmission
Metrology and Inspection
E
C
EC European Community
CE Communauté Européenne EDM Encryption/Decryption
(European Community) Module
Declaration of Conformity
EEC European Economic
CEE Certification of Electrical Community
Equipment (Zertifikat der
EMA Intruder alarm system
internationalen
Kommission für EMC Electromagnetic
Konformität elektrischer Compatibility
Betriebsmittel) EN European standard
CEN Comité Européen de EPP Encrypted PIN Pad
Normalisation
(Europäisches Komitee für F
Normung)
CEN Comité Européen de FCC Federal Communications
Normalisation (European Commission
Committee for
Standardization) G
CFR Code of Federal GmbH Limited liability company
Regulation
CIM Card Identification Module I
(security module)
ICES Interference Causing
CNS Chinese National
Equipment Standards
Standards
IP International Protection
CSA Canadian Standards
Association
L
Line Neutral Protective Earth

01750203983 B CINEO C4040 - Installation Guide V


Abbreviations

M
MM Modular Marker of ID card
(evaluation by means of
security modules like MM
box or CIM 06)

R
RSI Remote Status Indicator

S
SELV Safety Extra-Low Voltage

T
TN network Power supply
network in accordance
with EN 60950

U
UL Underwriters Laboratories
Inc.
UPS Uninterruptible Power
Supply

V
VdS Association of Property
Insurance Companies

VI CINEO C4040 - Installation Guide 01750203983 B


Introduction
This installation guide provides all the information you require to plan and
prepare installation and to set up the CINEO C4040.

The is available in the following versions:


− The CINEO C4040 with 4-cassette RM3 in the device versions Frontload
and Rearload with the safe versions:
− UL safe
− CEN L safe

The following accessories are available:


− Remote status indicator (RSI):
RSI - standard
RSI - audio

Symbols used in this manual


− Text following this mark represents an item in a list.
" " Text in quotation marks contains references to other chapters or sections in
this document.

• Paragraphs following this symbol are actions to be performed in the order


in which they are specified.
Text following this symbol should be given special attention in order to
avoid damage and injury.

i This symbol identifies paragraphs which contain general notes to


facilitate use of the device and help avoid operating errors.

01750203983 B CINEO C4040 - Installation Guide 1


Important safety precautions Introduction

Important safety precautions


Please read the following notes carefully before doing any work on the
device.

Installation note
− When installing the device and/or doing any work on it, make sure that it is
disconnected from power.
− Remove the shipping restraints inside the unit which secure its components
during transportation if necessary for the installation (see enclosed
information sheet).

General safety precautions


This device complies with the relevant safety regulations for information
processing equipment.
− When moving the device from a cold to a warm environment, do not
operate it for at least two hours to prevent possible damage caused by
condensation.
− Only use the original packaging material to transport the device.
− Note the warning and information labels on the device.
− Unless otherwise stated, grasp the components only by the green ledge
when handling them.
− The device is equipped with a safety-tested power cable which must be
connected only to a suitable grounded outlet.
− Always hold the plug when removing the power cable. Never pull the cable
itself.
− Install cables in such a way that they will not be stepped on or tripped over
or damaged or crushed in any way.
− Have damaged power cables replaced immediately.

2 CINEO C4040 - Installation Guide 01750203983 B


Introduction

− Make sure that there is always free access to the sockets used or to the
electrical circuit-breakers of the house installation.
− In case of an emergency (e.g. damaged cabinets, controls or power cables,
liquids or foreign objects in the device) take the following steps:
Deactivate the device immediately by:
Switching off the automatic circuit-breaker or removing the fuse inset
from the fuse holder in the distribution box of the building installation;
Disconnecting the plug connector of the power supply cable from the
grounded socket in the building installation;
Switching off the ON/OFF switch on the power distributor;
Interrupting the power connection, if there is one, between the UPS
(uninterruptible power supply) and the device (see chapter
“Introduction” section "General power interrupt" in the operating
manual);
− During a thunderstorm, data transmission lines must not be connected or
disconnected.
− Always keep the device's vents free from obstruction to ensure proper air
circulation and to prevent malfunctions resulting from overheating.
− Only use accessories and extension components that have been approved
by us. Nonobservance can result in damage to the device or violations of
regulations concerning safety, radio interference and ergonomical
requirements.
− Note that there are only safety extra-low voltage circuits (SELV circuits) if
you want to feed voltage from an external source into prepared cables to
install additional electronics (e. g. EMA connection, relay panel for external
features).
− To clean and maintain the device only use cleaning agents approved by
WINCOR NIXDORF International GmbH (see chapter "Appendix" in the
operating manual).

01750203983 B CINEO C4040 - Installation Guide 3


Introduction

Repairs

Repair work may only be carried out by authorized personnel.

Unauthorized opening of the device or repair work carried out


improperly could result in considerable danger to the user.

In case of noncompliance, WINCOR NIXDORF International GmbH


excludes all liability.

Lithium batteries

The handling and the replacement should only be performed by


authorized service personnel who were trained by the
WINCOR NIXDORF International GmbH.

There is danger of fire or explosion if the batteries are handled


improperly. It is therefore important to note the following points:

– Avoid short circuits


– Never recharge the battery
– Avoid temperatures above +100 °C (+212 °F).
– Do not try to open the battery by force
– Do not allow the battery to come in contact with water or fire

The battery should only be replaced with the same or an equivalent


type recommended by WINCOR NIXDORF International GmbH (see
chapter “Appendix,” section “Consumables”).
Dispose of used batteries in compliance with national regulations and
the manufacturer's specifications.

Start-up

i Before operating the device, remove all parts inside of it which secure
its components during transportation or check whether they have been
removed (see info sheet supplied with the device).

4 CINEO C4040 - Installation Guide 01750203983 B


Planning the Installation
This chapter provides you with all the information you need to prepare the
installation.

Device dimensions
i All dimensions are specified in millimeters (inches). The views of the
device are not drawn to scale.
All device edges have a radius of 3 mm (0.12").

01750203983 B CINEO C4040 - Installation Guide 5


Device dimensions Planning the Installation

CINEO C4040 Frontload

2093 (82.40")
1485 (58.46")

1510 (59.45")
762 (30")

1
444 (17.48") 3 667 (26.26")
25 (0.98")

450 (17.72") (0.12") 670 (26.38")


932 (36.69")

1 Installation frame

6 CINEO C4040 - Installation Guide 01750203983 B


Planning the Installation Device dimensions

CINEO C4040 Rearload

2093 (82.40")
1485 (58.46")

1510 (59.45")
762 (30")

1
444 (17.48") 72/43*
25 (0.98")

450 (17.72") (2.83"/1.69"*)


3 (0.12") 766 (30.16")
772 (30.39")
932 (36.69")

1 Installation frame
* Standard lock: 43 mm (1.69")
Customer-specific lock: max. 72 mm (2.83")

01750203983 B CINEO C4040 - Installation Guide 7


Device dimensions Planning the Installation

Dimensions of cable areas

i The mentioned cable lead-ins only apply for the device version
CINEO C4040 Frontload with UL safe.

The following illustrations show the dimensions of the cable feed openings on
the device side and the rear side.

frontload with UL safe

62,5 (2.46")
27,5 (1.08")
27,5 (1.08")
62,5 (2.46")

42,5 (1.67")
102,5 (4.04")
52,5 (2.07")
112,5 (4.43")

8 CINEO C4040 - Installation Guide 01750203983 B


Planning the Installation Device dimensions

62,5 (2.46")
27,5 (1.08")

52,5 (2.07")
112,5 (4.43")

01750203983 B CINEO C4040 - Installation Guide 9


Installation options of device versions Planning the Installation

Installation options of device versions

i For safety reasons we recommend installing a rearload unit through


the wall (see possible installation with frame).

When installing a rearload device as a free-standing ATM or when


installing the frontload device always contact your insurance company
beforehand.

In case of doubt contact your Wincor Nixdorf consultant.

Possible installation Frontload Rearload


Installation without frame (free- yes yes
standing)

i Observe the necessary operation and maintenance space for the


various types of installation (see section "Space required for operation
and maintenance").

The area specified for the installation of the frame requires a short tool
(see section "Required operation and maintenance space").

10 CINEO C4040 - Installation Guide 01750203983 B


Planning the Installation Installation options of device versions

Installation without frame (free-standing)

01750203983 B CINEO C4040 - Installation Guide 11


Vent Planning the Installation

Vent
The device features forced air ventilation on the rear side by means of a built-
in fan. Make sure that the distance between the vents and the wall is always at
least 50 mm (1.97") (see also section "Space required for operation and
maintenance").

1 Air inlet
2 Air outlet

Storage if construction work is not yet


complete
i If interior construction work is not complete when installation is
planned, the device must be protected from damage caused by
building dust. You may use the plastic packing of the system for this
purpose.

12 CINEO C4040 - Installation Guide 01750203983 B


Planning the Installation Space required for operation and maintenance

Space required for operation and


maintenance
The illustrations below show the necessary operation and maintenance space
for the frontload and rearload version.

Ventilation area

Operation and maintenance space

(See illustrations on the following pages)

01750203983 B CINEO C4040 - Installation Guide 13


Space required for operation and maintenance Planning the Installation

Frontload version

550
(21.65")

(1.97")
50
50 50 (1.97")
(1.97")
600 (23.62")
600 (23.62")

1300 (51.18")
1200 (47.24")

1650 (64.96")

14 CINEO C4040 - Installation Guide 01750203983 B


Planning the Installation Space required for operation and maintenance

Rearload version

1650 (64.96")

1100 (43.31")
550 (21.65") 550 (21.65")

2710 (106.69")
50 50
(1.97") (1.97")

350 350
(13.78") (13.78")
800 (31.5")

1150 (45.28")

01750203983 B CINEO C4040 - Installation Guide 15


Installation site requirements Planning the Installation

Installation site requirements

The installation area must be flat and on one level with the surrounding floor.
Any differences in floor height in the installation area must be leveled out with
rustproof shims, for example. This is not part of the installation procedure, but
must be done by a contractor.
When choosing the installation site, make sure that
− bright room lighting, light reflections and direct sunlight shining on the
screen or display and on camera panes are avoided,
− the requirements concerning ambient conditions can also be met in lobbies
(see chapter "Appendix", section "Technical data"),
− existing underfloor heating, energy and/or communication cables, etc., are
not damaged when drilling the mounting holes.
If necessary, appropriate arrangements must be made.

i When selecting the installation site, noise emission should be taken


into account.
Fans in operation or the noise produced during a transaction could
disturb people in the immediate vicinity of the device and may
therefore need to be diminished with soundproofing (e.g. sound
insulation walls, etc.).
They must comply with the environmental conditions that apply to the
specific device (see chapter "Appendix", section "Technical data") and
the maintenance areas (see section "Space required for operation and
maintenance").

Load-carrying capacity
Ensure that the installation site has the required load-carrying capacity. You
will find the relevant device weight in the section "Installation specifications" in
the chapter "Appendix".

16 CINEO C4040 - Installation Guide 01750203983 B


Planning the Installation Installation site requirements

Notes on floor mounting


To achieve the security level stipulated by country-specific regulations and
meet the requirements of commercial insurance companies, the device must
be bolted to the load-bearing substructure of the floor.

Protection from removal by force in compliance


with EN and VdS guidelines

i According to the applicable guidelines VdS 2450 and EN 1143-1 the


safe and the installation frame form one unit.
For this reason CEN safes may only be mounted with the certified and
approved installation frames.
If the guidelines are not observed, the CEN certification becomes
invalid.

The device must be screwed to the load-bearing substructure of the installation


site or mounted on a suitable base.
Using the prescribed mounting materials, the following values relating to
resistance to removal of the safe from the installation frame are reached:
Resistance grade Minimum force required
(Resistance grade)
III 50 kN
IV 100 kN

The operator must provide a suitable base to protect it from removal by force.
We recommend reinforced concrete B25 (EN206 C20/25) or a higher-quality
concrete.

i Installation on raised or cavity flooring as well as on a floating floor is


not permissible according to the CEN standard.
In case of a mounting structure other than the one specified in the
respective sections "Mounting the installation frame" in the chapter
"Installation", always contact your insurance company beforehand.

01750203983 B CINEO C4040 - Installation Guide 17


Installation frame Planning the Installation

Installation frame

General information
A CINEO C4040 cannot be installed without the installation frame.
The installation frame is secured to the floor at the attachment points (see
section "Drilling diagrams").
Then the device (safe) is screwed to the installation frame.
How the safe is secured on the installation frame depends on the safe
construction type (UL or CEN III, CEN IV). For CEN safes, the safe
construction types are distinguished in resistance grades. The label showing
the resistance grade is located on the inside of the safe door.
Openings which are not used have to be closed by putting in the filling
pieces.Openings which are not used have to be closed by putting in the filling
pieces.

i For mounting material see section "Mounting sets" in the chapter


"Installation".

Securing the installation frame

The installation frame needs to be anchored in the floor at four attachment


points regardless of the safe construction type (UL, CEN L). These attachment
points are at position (1) and the alternative attachment points are at position
(2) (see following illustrations).
Depending on the ordered device version, the supplied installation frame can
be used only for the frontload and rearload versions. Take note of the
alignment of the installation frame.

i If the mounting set is not provided, use equivalent fastening material.

18 CINEO C4040 - Installation Guide 01750203983 B


Planning the Installation Installation frame

Dimensions of safe attachment points

i The installation frame must be secured using one threaded rod per
group of holes A to D. The installation frame is secured with a total of
four threaded rods.
In the following illustration the safe attachment points are dimensioned
based on the outer edge of the installation frame.

(See illustrations on the following pages)

01750203983 B CINEO C4040 - Installation Guide 19


Installation frame Planning the Installation

Frontload

379.5 (14.94")
54.5 (2.15") 5
232 (9.13")

1
A B
487 (19.17")

2
552 (21.73")

3
607 (23.9")

2
C
1
4 D
3

50.5 (1.99")
7 8
5

1 Attachment points of installation 5 Cable lead-ins into the


Installation frame Installation frame
2 Alternative attachment points 6 Area for cables
Installation frame 7 Customer panel side
3 Attachment points of safe 8 This side must always point
4 Attachment point of tear-off sensor towards the side with the safe
door

20 CINEO C4040 - Installation Guide 01750203983 B


Planning the Installation Installation frame

Rearload

393.5 (15.49")
64.5 (2.54") 5
8

177 (6.97")
(4.41")
112
3
57 (2.24")

4
432 (17.01")

A
1
B
2
6

3
2
C D
1

5 7
389.5 (15.33")

1 Attachment points of installation 5 Cable lead-ins into the


Installation frame Installation frame
2 Alternative attachment points 6 Area for cables
Installation frame 7 Customer panel side
3 Attachment points of safe 8 This side must always point
4 Attachment point of tear-off sensor towards the side with the safe
door

01750203983 B CINEO C4040 - Installation Guide 21


Installation frame Planning the Installation

Dimensions of cable areas


In the following illustration (see following page) the cable feed openings are
dimensioned based on the outer edge of the installation frame.
(See illustrations on the following pages)

22 CINEO C4040 - Installation Guide 01750203983 B


Planning the Installation Installation frame

Frontload

444 (17.48")
344 (13.54")
244.5 (9.63")
199.5 (7.85")
100 (3.94")
74 (2.91")
31.5 (1.24")
29 (1.14")
25 (0.98")
571 (22.48")
639 (25.16")
664 (26.14")

Cable lead-ins in the installation frame


Area for cables
7 Customer panel side
8 This side must always point to the side with the safe door.

01750203983 B CINEO C4040 - Installation Guide 23


Installation frame Planning the Installation

Rearload

444 (17.48")
415 (16.34")
412.5 (16.24")
370 (14.57")
344 (13.54")
244.5 (9.63")
199.5 (7.85")
100 (3.94")
25 (0.98")

93 (3.66")
741 (29.17")
766 (30.16")

Cable lead-ins in the installation frame


Area for cables
7 Customer panel side
8 This side must always point to the side with the safe door.

24 CINEO C4040 - Installation Guide 01750203983 B


Planning the Installation Tear-off sensor

Tear-off sensor
i All safes and installation frames have holes for mounting a tear-off
sensor.

To ensure that the tear-off sensor can be mounted after the device has been
installed, a hole for the tear-off sensor has to be drilled at the time the
installation frame is mounted.
To be able to mount the tear-off sensor, the hole has to be cleaned with a
vacuum cleaner and a resin cartridge (e.g. UPAT multicone, Fischer resin
cartridge R M) has to be inserted.
Thus the alarm technician will be able to mount the tear-off sensor in the safe
easily after the device is installed (see also illustration "Mounting structure" in
the corresponding sections of the chapter "Installation").
Ask your alarm technician about the size of the hole and the fitting. The
maximum diameter for the hole to take the fixing is:

− 20 mm (0.79’’) in the installation frame


− 22 mm (0.87’’) in the safe

The mounting material (threaded rod, cartridge) is to be provided by the alarm


technician. The length of the threaded rod depends on the installation frame
you use (see chapter "Installation").The length of the threaded rod depends on
the installation frame you use (see chapter "Installation").

No power or data cables may be installed below the RM3 inside the
safe.

01750203983 B CINEO C4040 - Installation Guide 25


Drilling diagrams Planning the Installation

Drilling diagrams
The following figures specify the distance from the edge of the different device
versions of the drill holes that are used to secure CINEO C4040 to the
installation frame.

i The installation frame is 3 mm (0.12") smaller than the safe all around.

(See illustration on the following page)

26 CINEO C4040 - Installation Guide 01750203983 B


Planning the Installation Drilling diagrams

Drilling diagram Frontload

382.5 (15.06")
57.5 (2.26")

(4.41")
182 (7.17")
112
382 (15.04")

1
452 (17.8")
490 (19.29")

552 (21.73")
2

482 (18.98")
1

2
3

53.5 (2.11")

1 Attachment points of installation frame


2 Alternative attachment points of installation frame
3 the tear-off sensor
Drilling depths:
Holes for installation at least 180 mm (7.09") with 125 mm (4.92") in
frame: concrete. For the hole diameter please refer to the
mounting instructions of the caulking cartridge
supplied with the mounting set
Hole for tear-off at least 40 mm (1.57") in concrete.
sensor: Ask your alarm technician about the size of the hole
and the cartridge.

01750203983 B CINEO C4040 - Installation Guide 27


Drilling diagrams Planning the Installation

Drilling diagram Rearload


396.5 (15.61")
67.5 (2.66")

180 (7.09")
(4.65")
188 (7.4")

218 (8.58")
118

288 (11.34")
3
488 (19.21")
558 (21.97")

392.5 (15.45")

1 Attachment points of installation frame


2 Alternative attachment points of installation frame
3 the tear-off sensor
Drilling depths:
Holes for installation at least 180 mm (7.09") with 125 mm (4.92") in
frame: concrete. For the hole diameter please refer to the
mounting instructions of the caulking cartridge
supplied with the mounting set
Hole for tear-off at least 40 mm (1.57") in concrete.
sensor: Ask your alarm technician about the size of the hole
and the cartridge.

28 CINEO C4040 - Installation Guide 01750203983 B


Planning the Installation Power and data cables

Power and data cables

General
When the cables enter the device from below, make sure that the
cables cannot be sheared off when the system is moved.

To connect the device, power and data cables are required. In standard
deliveries, the connections for all the device's power and data cables are
situated near the cable feed opening in the safe. The power cable that is
included in delivery has a standard length of 2.5 m (8.20 ft). The device is
shipped with one power cable. Other ready-to-use lengths of power and data
cables can be ordered if needed via the hardware configurator or must be
provided by the customer. Please refer to the corresponding illustrations in this
guide for the positioning of the cables.
To lay the cables inside the installation frame and in the safe, filling pieces
may be removed so that cable sets can be inserted in the cable feed openings
(see illustration). These filling pieces must then be replaced after the cables
have been laid. The cable exit points in the floor must be kept clear to ensure
that the cables are not bent or damaged.

i Make sure that the cables provided on-site are long enough to be laid
through the installation frame into the safe.

Avoid excess lengths of cable by shortening them where necessary.


You must ensure that connecting cables do not impede or actually
damage any moving components.

i For the dimensions of the cable feed areas please refer to the section
"Dimensions of cable feed areas".

01750203983 B CINEO C4040 - Installation Guide 29


Power and data cables Planning the Installation

Cable lead-ins into the safe

Cable lead-in into the safe from the side or from the rear

i The laterally or the connecting cable at the rear only applies for the
device version CINEO C4040 Frontload with UL safe.
CINEO C4040 Frontload with UL safe

1 Cable feed opening

i You will also find details of the position of the cable feed opening for
the device in the section „Device dimensions“.

30 CINEO C4040 - Installation Guide 01750203983 B


Planning the Installation Power and data cables

Cable lead-in into the safe from below


CINEO C4040 Frontload

5 Cable lead-in in the installation frame


6 Cable feed through the floor
7 Customer panel side
8 Side with safe door

1 Cable feed opening

No power or data cables may be installed below the RM3 inside the
safe.
You will also find the position of the cable feed opening for the device
in the section "Installation frame".

01750203983 B CINEO C4040 - Installation Guide 31


Power and data cables Planning the Installation

CINEO C4040 Rearload

5 Cable lead-in in the installation frame


6 Cable feed through the floor
7 Customer panel side
8 Side with safe door

1 Cable feed opening

No power or data cables may be installed below the RM3 inside the
safe.
You will also find the position of the cable feed opening for the device
in the section "Installation frame".

32 CINEO C4040 - Installation Guide 01750203983 B


Planning the Installation Transport path requirements

Power supply
The device must only be connected to a TN system. In addition to the power
supply for the device, grounding outlets must be provided by the customer for
supplementary equipment such as a modem.

L N PE

1 Fuse or automatic circuit-breaker


2 CINEO C4040 connnection
3 Modem connection
4 Connection of miscellaneous equipment

Remote status indicator


The optional remote status indicator comes with a 50 m (164.1 ft) connecting
cable. During planning, the position for installation and cable routing must be
defined (see also chapter "Installing the remote status indicator").

Transport path requirements

The device is equipped with a shipping crate and can be transported with a
pallet lift truck. The forks of the truck must be pushed as far as possible
underneath the device from the front or the rear.

01750203983 B CINEO C4040 - Installation Guide 33


Transport path requirements Planning the Installation

The entire transportation route, like the installation site, must be checked for
load capacity and, if necessary, strengthened as appropriate before the
installation date. In order to avoid damage at the floor covering, panels (e.g.
beaverboard) should be laid on the floor for the transport with a pallet lift truck.
Observe the ambient condition requirements for transportation and storage
(see chapter "Appendix", section "Technical data").
Due to the shipping crate some dimensions are different (see illustrations
below).

Device version Frontload


1655 (65.16")

1 1
606 (23.86") 470 (18.5")
145 (5.71")

670 (26.26") 670 (26.38")


870 (34.25")

1 Shipping crate

34 CINEO C4040 - Installation Guide 01750203983 B


Planning the Installation Transport path requirements

Rearload version

1655 (65.16")

1 1
606 (23.86") 520 (20.47")
145 (5.71")

670 (26.26") 720 (28.35")


920 (36.22")
1132 (44.57")

1 Shipping crate

01750203983 B CINEO C4040 - Installation Guide 35


Transport path requirements Planning the Installation

i Check beforehand if there is enough space to move the device


through doors and hallways.
The following illustration should help you determine if the space is
sufficient. It shows the device on a standard lift truck.
With the help of the grid (100 mm x 100 mm (3.94" x 3.94")) you can
draw the actual dimensions of the door and the hallway to find out if
there is enough space for transportation. Refer to the next page for an
example.

Frontload version

540 (21.26")
670 (26.38")

1540 (60.63")

36 CINEO C4040 - Installation Guide 01750203983 B


Planning the Installation Transport path requirements

Rearload version

540 (21.26")
670 (26.38")

1540 (60.63")

01750203983 B CINEO C4040 - Installation Guide 37


Transport path requirements Planning the Installation

Example with minimum transport path measurements


Frontload version

690 (27.17")
1900 (74.8")

540 (21.26")
670 (26.38")

1540 (60.63")

38 CINEO C4040 - Installation Guide 01750203983 B


Planning the Installation Transport path requirements

Rearload version

690 (27.17")
1900 (74.8")

540 (21.26")
670 (26.38")

1540 (60.63")

01750203983 B CINEO C4040 - Installation Guide 39


Transport path requirements Planning the Installation

40 CINEO C4040 - Installation Guide 01750203983 B


Installation
This chapter describes the individual steps to be taken to install the device.
To guarantee a better structural safety, it is mandatory that the
CINEO C4040 is screwed to the floor or to the installation frame which
is screwed to the floor.
For the screwing, only the safe of the CINEO C4040 is allowed to be
opened and the safe unit of the RM3 is allowed to be pulled out.
For the screwing, the equipment carriage and the head unit of the RM3
need to be pushed in the operating unit of the CINEO C4040. The
operating unit of the CINEO C4040 needs to be closed.

i All dimensions are specified in millimeters (inches). The figures are not
drawn to scale.

Contact the person in charge of planning the installation to verify that


all preparatory work has been done completely and correctly and that
none of the required power and data cables are missing.

Removing the packing


Remove the packing material of the CINEO C4040.

• Dispose of the packaging which is no longer needed according to the


regulations of your country.

01750203983 B CINEO C4040 - Installation Guide 41


Removing the shipping crate Installation

Removing the shipping crate

General information
For transportation the device is equipped with a shipping crate. This must be
removed before installation.

i To move the device push against the sides of the safe only as shown
in the illustration below.

42 CINEO C4040 - Installation Guide 01750203983 B


Installation Removing the shipping crate

Disassembly
Proceed as follows to remove the shipping crate:
Remove the screws of the shipping
crate from underneath.

4x

Lift the device with the help of the lift


truck (1).

Don't move the device in this


situation, it risks to tip over!

Remove the shipping crate of


CINEO C4040 (2).

• Dispose of the shipping crate which is no longer needed according to the


regulations of your country.

01750203983 B CINEO C4040 - Installation Guide 43


Mounting sets Installation

Mounting sets
i The mounting sets are supplied with the installation frame of the
CINEO C4040.
The mounting set for the tear-off sensor is not supplied with the
device.

Mounting set 01750006706 installation frame for


UL / CEN L safe

i If the mounting set is not provided, use equivalent fastening material.


The procedure for mounting the installation frame or the installation
rack described in the sections of the installation versions assumes that
the provided mounting set 01750006706 is used. If you are using
different fastening materials please follow the instructions included
with those items.

Item Quantity required


Mounting set for installation frame (supplied
with installation frame)
– Caulking cartridge (two-component mortar) 1
A caulking gun is not included in the delivery package.
– Threaded rod M16 x 300 4
(DIN 976, property class 8.8)
– Hexagon nut M16 (DIN 971-1) 4
– Washer A 17 DIN 125-St 4

Mounting set 01750078516 (for UL / CEN L safe)


on installation frame
Item Quantity
required

44 CINEO C4040 - Installation Guide 01750203983 B


Installation Overview of installation types

– Pan head screw M16 x 40 4


(ISO 4762, property class 10.9)
– Washer A 17 ISO 7089-St 4

Overview of installation types

Possible installation Frontload Rearload


Installation without frame (free- yes yes
standing)

i Observe the necessary operation and maintenance space for the


various types of installation (see section "Space required for operation
and maintenance").

The area specified for the installation of the frame requires a short tool
(see section "Required operation and maintenance space").

i For installation with a frame the device must have been prepared for
this type of installation in the factory when it is shipped.

Installation without frame


The device can either be installed free-standing, in front of a wall or in a niche.

01750203983 B CINEO C4040 - Installation Guide 45


Installation without frame Installation

Mounting the installation frame

i Observe the specified maintenance space when positioning the device


and the installation frame (see chapter "Planning the Installation",
section "Space required for operation and maintenance").
Make sure that the clearance between the vents and the wall is at
least 50 mm (1.97") (53 mm (2.09") in relation to the installation
frame).

i The installation area must be flat and on one level with the surrounding
floor. Any differences in floor height in the installation area must be
leveled out with rustproof shims, for example.

Securing the installation frame

The installation frame needs to be anchored in the floor at four attachment


points regardless of the safe construction type (UL, CEN L). These attachment
points are at position (1) and the alternative attachment points are at position
(2) (see following illustrations).
Depending on the ordered device version, the supplied installation frame can
be used only for the frontload and rearload versions. Take note of the
alignment of the installation frame.

i If the mounting set is not provided, use equivalent fastening material.

• Align the installation frame and mark the holes to be drilled for mounting
the installation frame (see illustration below).

i If a tear-off sensor is to be installed as agreed with the financial


institution or the alarm technician, also mark the holes for the tear-off
sensor (see illustrations below).

i The installation frame must be secured using one threaded rod per
group of holes A to D. The installation frame is secured with a total of
four threaded rods.

46 CINEO C4040 - Installation Guide 01750203983 B


Installation Installation without frame

Frontload Rearload

8 5
5
3

A 4
1
A B 1
2 B
3 2
6
6

2 3
C 2
1 C D
4 1
D
3

7 8
5
7
5

1 Attachment points of installation 5 Cable lead-ins into the


Installation frame Installation frame
2 Alternative attachment points 6 Area for cables
Installation frame 7 Customer panel side
3 Attachment points of safe 8 This side must always point
4 Attachment point of tear-off sensor towards the side with the safe
door

• Drill the required four holes and the hole for the tear-off sensor, if
necessary (see following figures).

01750203983 B CINEO C4040 - Installation Guide 47


Installation without frame Installation

i Installation on raised or cavity flooring as well as on floating screed is


not admissible according to CEN standard. If the mounting structure
differs from the one described below (see illustration below), it must be
approved by the insurer.

To ensure that the safe does not become detached, the threaded rods
of the installation frame must be fastened in the concrete foundation.

The drilled holes in the concrete foundation must have a depth of at


least 125 mm (4.92") for the installation frame (see illustration below).

For the hole diameter please refer to the mounting instructions of the
caulking cartridge.

The drilled hole in the concrete foundation must have a depth of at


least 40 mm (1.57") for the tear-off sensor (see illustration below).
Consult your alarm technician about the size of the hole and the fixing.

48 CINEO C4040 - Installation Guide 01750203983 B


Installation Installation without frame

Mounting structure

CEN
2 3 4 5 6 7
UL

(0.98")
25
1

(min. 4.92")
min. 125

*
(min. 1.57")
min. 40

1 Safe 5 Screed
2 Mounting set for safe 6 Concrete
3 the tear-off sensor 7 Mounting set for installation frame
4 Installation frame 8 Top surface of finished floor

* The overall drilling depth depends on the constructional situation. The


threaded rods must be anchored at least 125 mm in the load-bearing
concrete.
Excess lengths must be shortened correspondingly or, if necessary in
case of deeper floor anchorages, be replaced by equivalent threaded
rods.

• Clean the bore holes as specified in the mounting instructions of the


caulking cartridge.

01750203983 B CINEO C4040 - Installation Guide 49


Installation without frame Installation

4x Secure the threaded rods in the


concrete foundation (1) as specified in
the mounting instructions of the
caulking cartridge.

The threaded rods must


i protrude at a minimum 24 mm
(0.94") and at a maximum 25
mm (0.98").

i If the mounting set is not provided, use equivalent fastening material.

• Insert the cartridge for the tear-off sensor if required.

i The space inside the installation frame allows cable lead-in through
cable ducts in the floor.

Frontload Rearload

5 Cable lead-in in the installation frame


6 Cable feed through the floor
7 Customer panel side
8 Side with safe door

50 CINEO C4040 - Installation Guide 01750203983 B


Installation Installation without frame

If the connecting cables on the site


are not located on the safe door
8 5b side:
Insert the data lines, the connecting
cable of the remote status indicator
(optional) and the power cord through
the cable lead-ins and if necessary
through the cable openings behind the
safe door side (8) of the installation
frame, as in the example shown here.

Make sure that the connecting


cables are laid loosely and are
not crushed by the installation
frame.

5a

4x Push the installation frame onto the


threaded rods (1) as shown in the
illustration as an example.
Secure the installation frame using one
hexagon nut and one washer for each
of the 4 attachment points (2) (for
material see section "Mounting set").
i Iftimes
applicable, note the hardening
of the mounting material.

The threaded rods must not


protrude beyond the installation
frame. If necessary, level the
threaded rods.

01750203983 B CINEO C4040 - Installation Guide 51


Installation without frame Installation

Mounting the device on the installation frame

• Push the device onto the installation frame.


Ensure that no cables are damaged in the process.

• Open the safe door (see chapter "Basic Operation" in the operating
manual).

• If it is necessary for the installation remove those parts inside the unit which
secure its components during transportation (see enclosed information
sheet).

• Pull out the RM3 (see chapter "Basic Operation" in the operating manual).

Screwing the device on the installation frame


Using four hexagon nuts and four
washers (1), screw the device to the
floor (for material see section
"Mounting sets").

4x

52 CINEO C4040 - Installation Guide 01750203983 B


Installation Start-up

Installing the power and data cables in the device


Undo the two screws (1) and remove
the filling piece of the safe underneath.

Feed the cable into the safe (1).


Replace the filling piece of the
installation frame (2) and fix it with the
earlier removed screw (3).
Replace the filling piece of the safe
and fix it with the two screws (4).

General information

• Close the device.

Start-up
The service technician will connect the power and data cables.

01750203983 B CINEO C4040 - Installation Guide 53


Start-up Installation

Check power plugs on the power distributor


You have to check that the power plugs are fitted correctly before
i using the power switch on the power distributor.

Plug all power plugs (1) in the power


distributor.
Then remove the label (2).

The number of power plugs


i depends on the individual
2 configuration.

54 CINEO C4040 - Installation Guide 01750203983 B


Installing the Remote Status Indicator

Remote status indicator - standard

Delivery package

Pos. Item Quantity


required
1 Remote Status Indicator - Standard (01750047663) 1
with 50 m (164.1 ft) connecting cable
(dimensions: 101.2 x 45.7 x 27 mm
(3.98" x 1.8" x 1.06") (W x H x D))
2 Phillips screws SPAX 2.5 x 20 (countersunk head) 2
3 Fixings Ø 4 mm (0.16") 2

i The enclosed mounting material is used to secure the indicator to


masonry or wooden paneling.

01750203983 B CINEO C4040 - Installation Guide 55


Remote status indicator - standard Installing the Remote Status Indicator

Installation

• Remove the standard remote status indicator from the packaging.


Use a screwdriver to press carefully
1 through openings (1) and (2) until the
tabs behind them disengage.
3
2 Remove the front cover (3) forwards.

When drilling the mounting


holes, take note of the
constructional situation
(energy, media line, etc.).

Position the lower section and mark


the points where it is to be secured.

• In masonry only:
Drill the necessary bores: drill depth: 20 mm (0.79"), drill diameter: 4 mm
(0.16"), and insert the enclosed fixings in the holes.
Secure the lower section to the wall
with the enclosed screws and press
the front cover onto the lower section.

56 CINEO C4040 - Installation Guide 01750203983 B


Installing the Remote Status Indicator Remote status indicator - standard

2 An adhesive label with the


i number 1 is applied in the
factory.

Remove the required label (1) and


1 apply it to the space provided (2) on
the standard remote status indicator.

• Lay the connecting cable of the standard remote status indicator to the
appropriate device.

Connection to the relay panel for external


features

• Open the device (see the device's operating manual).

• Route the connecting cable through the cable feed openings or the lead-ins
into the device (see the section for the appropriate installation version in
the chapter "Installation").

• Lay the connecting cable in the device to the relay panel for external
features so that it cannot be damaged when components are pulled out.

• Shorten the connecting cable if so required to the appropriate length (see


section "Shortening the cable ends").

Marking on wires

i The wires are marked with an adhesive label at the end as follows:

RED - 11 RED LIGHT


WHITE - 12 YELLOW LIGHT
GREEN - 13 GREEN LIGHT
BLACK - 14 GND

01750203983 B CINEO C4040 - Installation Guide 57


Remote status indicator - standard Installing the Remote Status Indicator

• Connect the individual wires to the relay panel for external features as
follows:

11 121314

Pin Name
11 Wire 'RED - 11 RED LIGHT'
12 Wire 'WHITE - 12 YELLOW LIGHT'
13 Wire 'GREEN - 13 GREEN LIGHT'
14 Wire 'BLACK - 14 GND'

• Close the device.

58 CINEO C4040 - Installation Guide 01750203983 B


Installing the Remote Status Indicator Remote status indicator - audio

Remote status indicator - audio

Delivery package

Pos. Item Quantity


required
1 Remote Status Indicator - Audio (01750069332) 1
with 50 m (164.1 ft) connecting cable
(dimensions: 118 x 96.5 x 40.5 mm
(4.65" x 3.8" x 1.59") (W x H x D))
2 Phillips screws SPAX 4 x 40 2
(half-round screws)
3 Fixings Ø 6 mm (0.24") 2

i The enclosed mounting material is used to secure the indicator to


masonry or wooden paneling.

01750203983 B CINEO C4040 - Installation Guide 59


Remote status indicator - audio Installing the Remote Status Indicator

Installation

• Remove the audio remote status indicator from the packaging.


Loosen screw (1). Move the back
panel (2) to one side at the bottom and
pull the panel downwards out of the
front cover.

When drilling the mounting


holes, take note of the
constructional situation
(energy, media line, etc.).

Position the back panel and mark the


points where it is to be secured.

Allow sufficient space to install


i the connecting cable on the
right (approx. 20 mm (0.79")).

60 CINEO C4040 - Installation Guide 01750203983 B


Installing the Remote Status Indicator Remote status indicator - audio

• In masonry only:
Drill the necessary bores: drill depth: 40 mm (1.57"), drill diameter: 6 mm
(0.24"), and insert the enclosed fixings in the holes.
Secure the lower part to the wall with
the screws supplied and mount the
front cover on the back panel as
described above under removal.

2 An adhesive label with the


i number 1 is applied in the
factory.

Remove the required label (1) and


apply it to the space provided (2) on
the audio remote status indicator.
1

• Lay the connecting cable of the audio Remote Status Indicator to the
appropriate device.

01750203983 B CINEO C4040 - Installation Guide 61


Remote status indicator - audio Installing the Remote Status Indicator

Connection to the relay panel for external


features

• Open the device (see the device's operating manual).

• Route the connecting cable through the cable feed openings or the lead-ins
into the device (see the section for the appropriate installation version in
the chapter "Installation").

• Lay the connecting cable in the device so that it cannot be damaged when
components are pulled out.

• Shorten the connecting cable if so required to the appropriate length (see


section "Shortening the cable ends").

Marking on wires

i The wires are marked with an adhesive label at the end as follows:

RED - 11 RED LIGHT


WHITE - 12 YELLOW LIGHT
GREEN - 13 GREEN LIGHT
BLACK - 14 GND

62 CINEO C4040 - Installation Guide 01750203983 B


Installing the Remote Status Indicator Remote status indicator - audio

• Connect the individual wires to the relay panel for external features as
follows:

11 121314

Pin Name
11 Wire 'RED - 11 RED LIGHT'
12 Wire 'WHITE - 12 YELLOW LIGHT'
13 Wire 'GREEN - 13 GREEN LIGHT'
14 Wire 'BLACK - 14 GND'

• Close the device.

01750203983 B CINEO C4040 - Installation Guide 63


Shortening the cables Installing the Remote Status Indicator

Shortening the cables

Adapting the cable length at the relay panel end

• Shorten the cable end as shown in the following diagram.

60 (23.62") 7 You must strip 60 mm (2.36") of the


(0.28") cable insulation and 7 mm (0.28") of
the individual wire insulation. The
individual wire ends must be twisted.

• Connect the cable as described in the section "Installation".

Adapting the cable length at the standard remote


status indicator end
Use a screwdriver to press carefully
1 through openings (1) and (2) until the
tabs behind them disengage.

3 Remove the front cover (3) forwards.


2

Release the four terminals of the


terminal strip (1) and remove the front
cover.

64 CINEO C4040 - Installation Guide 01750203983 B


Installing the Remote Status Indicator Shortening the cables

1 Remove screws (1) and (3) and the


strain relief (2).
Remove the connecting cable.

• Shorten the connecting cable to the desired length.

• Shorten the cable end as shown in the following diagram.

4.5 60 (23.62") You must strip 60 mm (2.36") of the


(0.18") cable insulation and 4.5 mm (0.18") of
the individual wire insulation. The
individual wire ends must be twisted.

• Lead the connecting cable through the opening in the lower section and
secure it with the strain relief.

Marking on wires

i The wires are marked with an adhesive label at the end as follows:

RED - RED LIGHT


WHITE - YELLOW LIGHT
GREEN - GREEN LIGHT
BLACK - GND

01750203983 B CINEO C4040 - Installation Guide 65


Shortening the cables Installing the Remote Status Indicator

• Connect the individual wires as follows:

Pin Name
1 Wire 'RED - RED LIGHT'
2 Wire 'WHITE - YELLOW LIGHT'
3 Wire 'GREEN - GREEN LIGHT'
4 Wire 'BLACK - GND'

• Press the front cover onto the lower section. Ensure that no wires are
damaged in the process.

66 CINEO C4040 - Installation Guide 01750203983 B


Installing the Remote Status Indicator Shortening the cables

Adapting the cable length at the remote status


indicator (audio)
Loosen screw (1). Move the back
panel (2) to one side at the bottom and
pull the panel downwards out of the
front cover.

Remove the two screws (1) and move


the board (2) to one side.

01750203983 B CINEO C4040 - Installation Guide 67


Shortening the cables Installing the Remote Status Indicator

Release the four terminals of the


terminal strip and disconnect the cable
from the terminal strip (1).

Remove the connecting cable with the


spacer from cable guide (2).

Remove the spacer from the


connecting cable (see arrow).
Shorten the connecting cable to the
desired length.
Push the spacer back on the cable.

• Shorten the cable end as shown in the following diagram.


You must strip approx. 25 mm (0.98")
25
(0.98") of the cable insulation and 4.5 mm
(0.18") of the individual wire insulation.
4.5 The individual wire ends must be
(0.18")
twisted.

68 CINEO C4040 - Installation Guide 01750203983 B


Installing the Remote Status Indicator Shortening the cables

Marking on wires

i The wires are marked with an adhesive label at the end as follows:

RED - RED LIGHT


WHITE - YELLOW LIGHT
GREEN - GREEN LIGHT
BLACK - GND
• Connect the individual wires as follows (1):

Pin Name
1 Wire 'RED - RED LIGHT'
2 Wire 'WHITE - YELLOW LIGHT'
3 Wire 'GREEN - GREEN LIGHT'
4 Wire 'BLACK - GND'

• Press the connecting cable with the spacer into the cable guide (2).

• Mount the board and the back panel as described above under removal.

01750203983 B CINEO C4040 - Installation Guide 69


Shortening the cables Installing the Remote Status Indicator

70 CINEO C4040 - Installation Guide 01750203983 B


Appendix

Check list for installation preparations for


self-service systems
KS number * Order number
Device type
Customer address Delivery address/location
Name
Street
Town
Telephone
Contact

* Customer number or system's serial number


This check list has been created for all self-service systems. Most questions
can be answered yes or no. Some empty space is provided in the section
"Notes concerning installation preparation" for your convenience if you want to
note any questions or drafts.

After checking off all items, copy this list, send it to your head of
operations and make arrangements for an installation date.

Name:
Telephone number:
Fax number:

01750203983 B CINEO C4040 - Installation Guide 71


Check list for installation preparations for self-service systems Appendix

General information

Installation

in front of a wall through a wall free- encased


standing

yes no OK
Is the load carrying capacity of the floor sufficient
according to the installation documentation?
Is there floor heating in the installation area?
Are there cavities in the installation area (cable
duct, raised floor)?
Is the operation and maintenance space
sufficient?
Is the equipment screened from external light
(sunlight)?
Is a video surveillance system to be installed?
Is a door opener system to be installed?

Preparations

Construction work
yes no OK
Is the securing of cash-dispensers in the raw
concrete ensured (CEN standard)?
Is the frame aligned and fastened in accordance
with the installation instructions?
Has a wall cutout that may be required been
completed?
Are the ambient conditions met?

72 CINEO C4040 - Installation Guide 01750203983 B


Appendix Check list for installation preparations for self-service systems

Power and data cables


yes no OK
Are the AC power outlets available in accordance
with the installation instructions?
Are the data cables available?
Is the alarm connection prepared?
Have the camera connection and the door opener
been provided?

Organizational preparations
yes no OK
Is the generation prepared on the host?
Has the MM module or CIM06 been ordered and
is it available?
Have the encryption/decryption or EPP keys been
prepared?
Is the paper and money ready for start-up?
Have you discussed the diameter of the hole that
is to be drilled and the fixing to be used for the
tear-off sensor with the local alarm provider?
Diameter?
Fixing to be used?

01750203983 B CINEO C4040 - Installation Guide 73


Check list for installation preparations for self-service systems Appendix

Delivery and installation


yes no OK
Can a truck drive up to the installation location?
Are there steps or obstacles in front of the
building?
If so, how many?

Are there steps or obstacles inside the building?


If so, how many?

Are there mats or grates at the entrance?

Flooring materials on the path of transport


(please check off)

Screed/concrete Carpet Raised floor


Marble floor Tiles Others

Please enter the width of the most narrow


door

Please enter the width of the most narrow


hallway

Checked by customer: Checked by installation technician:

74 CINEO C4040 - Installation Guide 01750203983 B


Appendix Check list for installation preparations for self-service systems

Notes concerning installation preparation

01750203983 B CINEO C4040 - Installation Guide 75


Check list for installation preparations for self-service systems Appendix

76 CINEO C4040 - Installation Guide 01750203983 B


Appendix Technical data

Technical data

General installation conditions

Electrical characteristics of the supply network


Line voltage range: 110 - 120 V 220 - 240 V
Rated frequency: 50/60 Hz 50/60 Hz
Network type: TN (network with PE TN (network with PE
conductor) conductor)
Permissible tolerance for
rated voltage: -10 % to +6% -10 % to +6%
Permissible tolerance for
rated frequency: ±1 % ±1 %

01750203983 B CINEO C4040 - Installation Guide 77


Technical data Appendix

Device conditions
110 - 120 V 220 - 240 V
Idle mode Operation Idle mode Operation
(maximu (maximum
m) )

Nominal current 2.3 A 3.3 A 1.2 A 1.7 A


consumption:
Apparent power input:
230 VA 320 VA 240 VA 330 VA
Real power: 220 W 310 W 220 W 300 W
Power factor: 0.96 0.97 0.92 0.91
Leakage current: <3.5 mA <3.5 mA <3.5 mA <3.5 mA
Protection class: I I
Type of system Country-specific Country-specific
connection (wall outlet): protective contact plug protective contact plug
(CEE plug) pursuant to (CEE plug) pursuant to
IEC 309 IEC 309
Fuse Protection against Protection against
melting melting
10 A inert or circuit 10 A inert or circuit
breaker breaker
16 A 16 A

Degree of protection in IP20 IP20


acc. with EN 60529:

78 CINEO C4040 - Installation Guide 01750203983 B


Appendix Technical data

Installation specifications
CINEO C4040 Frontload Rearload
Dimensions:
Height: 1510 mm 1510 mm
(59.45 ") (59.45 ")
Width: 450 mm 450 mm
(17.72 ") (17.72 ")
Depth: 830 mm 932 mm
(32.68 ") (36.69 ")

Operation and maintenance 2.2 m² 2.8 m²


space: (23.68 ft²) (30.14 ft²)

Weight *:
UL safe:
Device weight: 440 kg 470 kg
(970.03 lb) (1036.17 lb)
Surface load: 14.64 kN/m² 13.56 kN/m²

CEN L safe:
Device weight: 385 kg 400 kg
(848.78 lb) (881.85 lb)
Surface load: 12.81 kN/m² 11.54 kN/m²

Max. ventilation capacity **: 184 m³/h 184 m³/h

* Weight figures refer to the empty weight of the device and the free-
standing installation type.
** dependent on temperature

i For detailed information on dimensions please refer to the installation


guide, chapter "Planning the Installation".

01750203983 B CINEO C4040 - Installation Guide 79


Technical data Appendix

Environmental conditions
Climatic environmental conditions in acc. with EN 60721

Air temperature Relative humidity


°C (°F) % r.h.
Operation (indoors): +5 to +40 10 to 85
(41 to 104)
Transport: -25 to +60 15 to 98
(-13 to 140)
Storage: +5 to +40 5 to 98
(41 to 104)

Mechanical environmental conditions in acc. with EN 60721

Class Notes
Operation 3M2 Building without significant vibrations caused
by other objects
Transport (in 2M2 All types of commercial vehicles and trailers
original packaging) as well as rail and air transport
Storage (in original 1M3 Noticeable vibration and shocks, e.g. by
packaging) machines or passing vehicles

80 CINEO C4040 - Installation Guide 01750203983 B


Appendix Technical data

Noise emission in acc. with EN 27779

Idle mode Operation *

Workplace-related sound pressure level


LpAm(at adjacent workplace) 34 dB 54 dB

* typical operating cycle

i Noise emissions should be taken into account when selecting the


installation location.
Fans or the noise volume associated with a transaction can be
perceived as disruptive when standing directly near the device; these
noises may have to be reduced through sound protection measures
(e.g. sound protection walls etc.).
They must comply with the environmental conditions that apply to the
specific device (see above) and the maintenance areas (see chapter
"Planning the Installation", section "Space required for operation and
maintenance").

01750203983 B CINEO C4040 - Installation Guide 81


Compliance with standards and certifications Appendix

Compliance with standards and


certifications

Standards met
Safety standards: IEC 60950,
EN 60950,
CSA C22.2-60950,
UL 60950,
BSMI Standard CNS 14336
EMC standards: EN 55022 / B,
EN 55024,
FCC CFR 47, part 15, subpart B, class A,
ICES-003 (CSA 108.8),
BSMI-Standard CNS 13438 class B

Conformity
The CE mark of conformity attached to the product or its package indicates
that the product complies with the requirements of the following EC directives:
− EMC Directive 2004/108/EC
− Low Voltage Directive 2006/95/EC
The corresponding statement of compliance has been issued by:
WINCOR NIXDORF International GmbH
Heinz-Nixdorf-Ring 1
33106 Paderborn
Germany

82 CINEO C4040 - Installation Guide 01750203983 B


Appendix Compliance with standards and certifications

Notes concerning radio interference suppression


and electrical safety
All other devices connected to this product must comply with the EMC
Directive 89/336/EEC including amending directive 93/68/EEC (as of
7/20/2009 EMC Directive 2004/108/EC) and the Low Voltage Directive
73/23/EEC including amending directive 93/68/EEC (as of 1/16/2007 Low
Voltage Directive 2006/95/EC).

Certification for data transmission


The certification number or CE mark of the data transmission module (if
available) is attached to the DT card or to the housing of the system unit.

FCC rules and Canadian Standard ICES - 003


NOTE: This equipment has been tested and found to comply with the limits for
a Class A digital device, pursuant to Part 15 of the FCC rules and Canadian
Standard ICES - 003. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operating in a
commercial environment. The equipment generates, uses and can radiate high
frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference
at his own expense.

UL 291, Level 1 (security Container)


In order to meet guideline UL 291, ensure the following during installation:
− The unit must be connected to a grounded receptacle.
− For a free-standing installation the security container of the ATM shall be
anchored in accordance with this instruction, either using the listed
anchoring devices or using similar devices. Each anchoring device shall

01750203983 B CINEO C4040 - Installation Guide 83


Environmental protection Appendix

withstand a 22,000 pound (97,861 N) vertical or horizontal force applied in


an attempt to remove the security container from its location.
If the free-standing installation is inside a building and the anchoring devices
cannot be secured to the building structure, the unit shall be attached to a steel
plate at least 4 feet by 8 feet by ½ inch thick (1.22 m by 2.44 m by
12.7 mm thick) or an equivalent structure so as to restrict the removal of the
teller machine from the building. The release mechanism of the attachment
devices shall only be accessible when the door of the security container is
open.

Environmental protection

Environmentally and recycling-friendly product


development
This product has been designed according to our corporate guideline
'Environmentally and recycling-friendly product development'.
This means that crucial criteria such as long life, choice of material and its
labeling, emissions, packaging, ease of disassembly and recyclability have
been taken into account. This saves resources and relieves the strain on the
environment.

Saving energy
Please switch on devices that need not be constantly running only when they
are actually needed. They should also be turned off when they are not needed
for longer periods of time.

Disposing of used consumables


Please dispose of printer consumables, batteries and cleaning and
maintenance materials according to national regulations (where relevant
complying with vendor specifications).

84 CINEO C4040 - Installation Guide 01750203983 B


Appendix Environmental protection

Labels on plastic case parts


Please do not stick any labels on plastic case parts since that would make
recycling more difficult.

Returning, recycling and disposing of used units


and consumables
Details regarding the return and recycling of used units and
consumables can be obtained from your local branch office or
from our Environmental Protection section (Referat
Umweltschutz):
Tel.: +49 (0) 52 51 693 67 07
Fax.: +49 (0) 52 51 693 77 67 07
E-mail: [email protected]

01750203983 B CINEO C4040 - Installation Guide 85


Environmental protection

86 CINEO C4040 - Installation Guide 01750203983 B


Notes

01750203983 B CINEO C4040 - Installation Guide


Published by
WINCOR NIXDORF International GmbH
D-33094 Paderborn

Order No.: 01750203983 B 1 GB