Plate Heat Exchanger: Applications Standard Design

The plate heat exchanger consists of a pack of corrugated metal plates. The number of plates is determined by the flow rate, physical properties of the fluids, pressure drop and temperature program. The plate corrugations promote fluid turbulence and support the plates against differential pressure.

Uploaded by

Nikhil Bhatia
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
95 views

Plate Heat Exchanger: Applications Standard Design

The plate heat exchanger consists of a pack of corrugated metal plates. The number of plates is determined by the flow rate, physical properties of the fluids, pressure drop and temperature program. The plate corrugations promote fluid turbulence and support the plates against differential pressure.

Uploaded by

Nikhil Bhatia
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

TL6

Plate heat exchanger


General heating and cooling duties. The plate heat exchanger consists of a pack of corrugated metal plates with portholes for the passage of the two fluids between which heat transfer will take place. The plate pack is assembled between a fix frame plate and a movable pressure plate and compressed by tightening bolts. The plates are fitted with a gasket which seals the interplate channel and directs the fluids into alternate channels. The number of plates is determined by the flow rate, physical properties of the fluids, pressure drop and temperature program. The plate corrugations promote fluid turbulence and support the plates against differential pressure. The plate and the pressure plate are suspended from an upper carrying bar and located by a lower guiding bar, both of which are fixed to a support column. Connections are located in the frame plate or, if either or both fluids make more than a single pass within the unit, in the frame and pressure plates.

Applications

Standard design

Typical capacities
Liquid flow rate Up to 20 kg/s (317 gpm), depending on media, permitted pressure drop and temperature program. Plate types TL6B Frame types FM, FG and FD

Working principle
Channels are formed between the plates and the corner ports are arranged so that the two media flow through alternate channels. The heat is transferred through the plate between the channels, and complete counter-current flow is created for highest possible efficiency. The corrugation of the plates provides the passage between the plates, supports each plate against the adjacent one and enhances the turbulence, resulting in efficient heat transfer.

Flow principle of a plate heat exchanger

STANDARD MATERIALS
Frame plate Mild steel, Epoxy painted Nozzles Carbon steel Metal lined: Stainless steel, Titanium Rubber lined: Nitrile, EPDM Pipe: Stainless steel Plates Stainless steel Alloy 316 / Alloy 304 Titanium, Alloy 254 SMO, Alloy C-276 Gaskets Nitrile, EPDM, HeatSeal, HNBR, VitonG

Dimensions
W 140 (5,5")

S4

S1

1036 (40,8")

S3 h

S2

625 - 1690 (24,6" - 66,5")

TECHNICAL DATA
Pressure vessel codes, PED, ASME, pvcALS Mechanical design pressure (g) / temperature FM pvcALS 1.0 MPa / 180C FM PED 1.0 MPa / 180C FG pvcALS 1.6 MPa / 180C FG PED 1.6 MPa / 180C FG ASME 150 psig / 320F FD pvcALS 2.5 MPa / 180C FD PED 2.5 MPa / 180C FD ASME 300 psig / 320F Measurements mm (inch) Type
TL6-FM / PED / pvcALS TL6-FG / PED / pvcALS TL6-FG / ASME TL6-FD / PED / pvcALS TL6-FD / ASME

H
1264 (49.8") 1264 (49.8") 1299 (51.1") 1264 (49.8") 1308 (51.5")

W
320 (12.6") 320 (12.6") 320 (12.6") 330 (13.0") 330 (13.0")

h
137 (5.4") 137 (5.4") 142 (5.6") 137 (5.4") 142 (5.6")

The number of tightening bolts may vary depending on pressure rating.

CONNECTIONS
Pipe connections (not for frame type FD) Straight threaded Size 50 mm ISO G2, NPT 2 Threaded inlet port Size 50 mm ISO G2 Straight threaded Size 65 mm ISO G2 , NPT 2 Flange connections FM pvcALS Size 50 / 65 mm FM PED FG pvcALS FG PED FG ASME Size 50 / 65 mm Size 50 / 65 mm Size 50 / 65 mm Size 50 - 65 Maximum heat transfer surface 102.0 m (1097 sq.ft) Particulars required for quotation Flow rates or heat load Temperature program Physical properties of liquids in question (if not water) Desired working pressure Maximum permitted pressure drop

DIN/GB/GOST PN16, ASME Cl.150 DIN PN16, ASME Cl. 150 DIN/GB/GOST PN16, ASME Cl. 150 DIN PN16, ASME Cl. 150 ASME Cl.150 DIN/GB/GOST PN40, ASME Cl.300 DIN PN40, ASME Cl. 300 ASME Cl. 300

FD pvcALS Size 50 / 65 mm FD PED FD ASME Size 50 / 65 mm Size 50 / 65 mm

PCT00102EN 0810

All rights reserved for changes in specifications without prior notification

How to contact Alfa Laval Up-to-date Alfa Laval contact details for all countries are always available on our website at www.alfalaval.com