MMS50C
MMS50C
DATA SHEET
Type Type
* Intermittent operation: the permissible values may occur for max. 10% of every minute.
** Peak load: the permissible values may occur for max. 1% of every minute.
*** For speeds lower than given, consult factory or your regional manager.
1. Intermittent speed and intermittent pressure drop must not occur simutaneously.
2. Recommended filtration is per ISO cleanliness code 20/16. A nominal filtration of 25 micron or better.
3. Recommend using a premium quality, anti-wear type mineral based hydraulic oil HLP(DIN51524) or HM ( ISO 6743/4).
If using synthetic fluids consult the factory for alternative seal materials.
4. Recommended minimum oil viscosity 13 mm²/s [70 SUS] at 50°C [122°F].
5. Recommended maximum system operating temperature is 82°C [180°F].
6. To assure optimum motor life fill with fluid prior to loading and run at moderate load and speed for 10-15 minutes.
page 1/6
MMS50C
3d generated view
To see model in 3D you should use Acrobat Reader with enable 3D view
page 2/6
NOTE: Showed dimensions are in nominal, for maximal values see table. L max LS max
NOTE: For additional dimensions and information about flange , shaft , endcover , etc. see next
page. 122.5
MMS50C
page 3/6
omit: Three bolts mount
S: Side ports
MMS50C
page 4/6
MMS50C
FUNCTION DIAGRAMS
The function diagrams data is for average performance of randomly selected motors at back pressure
5÷10 bar [72.5÷145 PSI] and oil with viscosity of 32 mm²/s [150 SUS] at 50°C [122°F].
page 5/6
MMS50C
DATA SHEET
Pressure Losses
page 6/6