General-Catalog Centrifuge
General-Catalog Centrifuge
2021 | 2022
CENTRIFUGES
INCUBATORS
DEAR PARTNER,
For more than 115 years, Hettich has been at your side when it comes to centrifu-
gation and incubation of vital samples. In support of the highly competent medical
and research personnel working daily in the laboratory, our products quietly help to
make processes more efficient and provide reliable results. These qualities are more
important today than ever before – in both the fight against global pandemics and
the development of new vaccines and treatments. We take on this responsibility with
a wide portfolio of centrifuges and incubators that comply with all current and future
regulatory standards and certifications so that you can concentrate on your work.
You will find these and other new products in the following pages. As always, our
products are backed by our 24 month Global Warranty and 10 year spare parts
support guarantee.
We thank you for your interest in Hettich and hope to continue our role as a trusted
partner in your laboratory.
Klaus-Günter Eberle
CEO
OVER
115
YEARS
TRADITION
& QUALITY
NEW PRODUCTS
INNOVATION IN CENTRIFUGATION –
THE DUAL CENTRIFUGE ZENTRIMIX 380 R
2
MORE TRANSPARENCY IN THE
CENTRIFUGATION OF BLOOD SAMPLES
page 160
3
CONTACT / SERVICE
CONTACT
RESPONSIBILITY
FOR YEARS
EUROPE, UK,
[email protected] + 49 7461 705 1402
BLAKANS
RUSSIA, UKRAINE,
[email protected] + 49 7461 705 1402
BELARUS, POLAND
NORTH- / SOUTH
[email protected] + 49 7461 705 1404
AMERICA
4
SERVICE
5 GOOD REASONS TO
CHOOSE HETTICH SERVICE
5 Parts and service are available for 10 years, even after a specific model
has been discontinued.
Our global network of Hettich subsidiaries and authorized In addition to our German headquarters we have branch
service providers ensure that customer challenges are offices in throughout Europe as well as the USA (North Ame-
addressed quickly and efficiently with real-time solutions. rica) and Singapore (ASEAN) to offer fast, local support. You
can find an overview of an authorized service provider for your
country on our Website: www.hettichlab.com/contact
You can reach us through the following email address:
*) Not available in all countries.
5
CONTENTS
MANUAL CENTRIFUGE EBA 200 | 200 S EBA 270 EBA 280 | 280 S HAEMATOKRIT 200
MIKRO 185 MIKRO 200 MIKRO 200 R MIKRO 220 MIKRO 220 R
ROTOFIX 32 A UNIVERSAL 320 UNIVERSAL 320 R ROTINA 380 ROTINA 380 R ROTINA 420 ROTINA 420 R ROTANTA 460
ROTOLAVIT II
ZENTRIMIX 380 R
BLOOD BANK
CYTO SYSTEMS ROLLING CABINET ACCESSORIES
HETTCUBE 200 HETTCUBE 200 R HETTCUBE 400 HETTCUBE 400 R HETTCUBE 600 HETTCUBE 600 R
6
CONTENTS
7
SMALL CENTRIFUGES
Benchtop performance in a compact footprint
The adaptable manual centrifuge can be simply clamped to any benchtop, with no need for electricity. Its self-lubricating
drive system makes it virtually maintenance-free.
10
centrifuge
Manual
TECHNICAL DATA
11
EBA 200 | 200 S
Top performance
for small laboratories
The EBA 200 and EBA 200 S are practical, compact centrifuges for small sample sizes. The high speed S model can deliver
reliable results in 3 minutes or less. An 8-place fixed angle rotor is included to hold standard blood and urine tubes up to 15
ml in capacity.
12
EBA 200 | 200 S
TECHNICAL DATA
AVAILABLE ROTORS
ANGLE ROTORS angle max. RPM max. capacity Cat. No page
13
EBA 200 | 200 S | SMALL CENTRIFUGES
Rotor
max. RPM EBA 200 | 200 S 6,000 min-1 | 8,000 min-1
max. RCF 3,461 | 6,153
max. capacity 8 x 15 ml
run up / run down, braked in sec 17 / 12 | 37 / 17
angle 33°
Cat. No. INCLUSIVE
Vessels
capacity in ml 0.5 1.5 2 4 5 6 15 1.1 – 1.4 2.6 – 3.4 2.7 – 3 4.5 – 5 4.9 7.5 – 8.5 9 – 10 5
Ø x L in mm 10.7 x 36 11 x 38 11 x 38 10 x 88 12 x 75 12 x 82 17 x 100 8 x 66 13 x 65 11 x 66 11 x 92 13 x 90 15 x 92 16 x 92 17 x 59
max. RCF 2) EBA 200 2,214 2,173 2,173 2,817 2,697 2,697 3,461 2,697 2,697 2,697 3,461 3,461 3,461 3,461 2,576
max. RCF 2) EBA 200 S 3,935 3,864 3,864 5,009 4,794 4,794 6,153 4,794 4,794 4,794 6,153 6,153 6,153 6,153 4,579
radius in mm 55 54 54 70 67 67 86 67 67 67 86 86 86 86 64
Cat. No. Pediatric microliter tubes tubes 2) blood collection / urine tubes -
+
12) 12) 12) 12) 12)
Adapter
boring Ø x L in mm 11 x 35 11 x 35 11 x 35 11.5 x 67.5 13.5 x 60 13.5 x 60 17.7 x 88 13.5 x 60 13.5 x 60 13.5 x 60 17.7 x 88 17.7 x 88 17.7 x 88 17.7 x 88 17 x 25
vessels per rotor 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8
Cat. No. 1063-8 (8 pcs.) 6305 1054-A 1054-A - 1054-A 1054-A 1054-A - - - - 1064
Vessels
capacity in ml 15 10 1.6 – 5 4–7 8 8.5-10 12
Ø x L in mm 17 x 120 15 x 102 13 x 75 13 x 100 16 x 125 16 x 100 17 x 102
max. RCF 2) EBA 200 3,461 3,461 2,697 3,461 3,461 3,461 3,461
max. RCF 2) EBA 200 S 6,153 6,153 4,794 6,153 6,153 6,153 6,153
radius in mm 86 86 86 86 86 86 86
Cat. No. - blood collection / urine tubes
+
12)
Adapter
boring Ø x L in mm 17.7 x 88 17.7 x 88 13.5 x 60 13.5 x 79 17.7 x 88 17.7x 88 17.7x 88
vessels per rotor 4 8 8 8 4 8 4
Cat. No. - - 1054-A 1058 - - -
2) Please note that the RCF values indicated refer only to rotor performance. The max. permissible RCF of tubes used should be verified with the individual manufacturers. The max.
RCF for glass tubes annotated with footnote 2) is 4,000.
12) For the EBA 200 only! Model EBA 200 S is supplied as standard with an adapter for these tubes.
14
EBA 200 | 200 S
PACKAGES
EBA 200 S BLOOD TUBE PACKAGE 1 number of vessels volume (ml) size (mm) RPM RCF
- 1 x EBA 200 S centrifuge 1802 8 1.6 - 5 13 x 75 8,000 4,794
incl. anlge rotor, 8-place 8 4-7 13 x 100 8,000 6,153
- 8 x adapter, 1-place 1054-A
8 8.5 - 10 16 x 100 8,000 6,153
- 8 x adapter, 1-place 1058
8 8 16 x 125 8,000 6,153
1802SET1
EBA 200 BLOOD TUBE PACKAGE 2 number of vessels volume (ml) size (mm) RPM RCF
- 1 x EBA 200 centrifuge incl. angle rotor 1800 8 1.6 - 5 13 x 75 6,000 2,697
- 8 x adapter, 1-place 1059 8 4-7 13 x 100 6,000 3,461
- 8 x adapter, 1-place 1058
8 8.5 - 10 16 x 100 6,000 3,461
4 8 16 x 125 6,000 3,461
1800SET2
PRODUCT VIDEOS
Would you like to learn more about this product? Scan the QR Code to visit
our YouTube channel:
www.youtube.com/hettichlabtechnology
15
EBA 270
Superior seperation results
in medical applications
The EBA 270 is a small centrifuge with a built-in swing-out rotor that has been developed specifically for use in clinical
settings. It can centrifuge blood tubes and urine tubes up 15 ml in volume at a maximum speed of 4,000 RPM / 2,254 RCF.
Its 90° rotor is ideally suited for spinning blood tubes containing a separating gel.
16
EBA 270
TECHNICAL DATA
EBA 270
voltage *) 200 – 240 V 1 ~
frequency 50 – 60 Hz
consumption 130 VA
emission, immunity EN / IEC 61326-1, class B
max. capacity 6 x 15 ml
max. RPM 4,000 min-1
max. RCF 2,254
running time 1 – 99 min, continuous run, short cycle mode (impulse button)
dimensions (W x D x H) 326 x 389 x 239 mm
weight approx. 14 kg
max. noise level ≤ 51 dB (A)
Cat. No. 2300
AVAILABLE ROTORS
SWING-OUT ROTORS angle max. RPM max. capacity Cat. No page
17
EBA 270 | SMALL CENTRIFUGES
Rotor
max. RPM | max. RCF 4,000 min-1 | 2,254
max. capactiy 6 x 15 ml
run up | run down, braked in sec 10 | 22
angle | max. noise level 90° | 51 dB (A)
Cat. No. INCLUSIVE
Vessels
capacity in ml 0.5 0.5 1.5 1.5 2 2 4 5 6 15 1.1 – 1.4 2.6 – 3.4 2.7 – 3 4 – 5.5 4.5 – 5
Ø x L in mm 10.7 x 36 10.7 x 36 11 x 38 11 x 38 11 x 38 11 x 38 10 x 88 12 x 75 12 x 82 17 x 100 8 x 66 13 x 65 11 x 66 15 x 75 11 x 92
max. RCF 2) 1,359 1,359 1,377 1,377 1,377 1,377 2,254 1,807 1,807 2,254 1,807 1,807 1,807 2,254 2,254
radius in mm 76 76 77 77 77 77 126 101 101 126 101 101 101 126 126
Cat. No. Pediatric microliter tubes tubes 2) blood collection / urine tubes
+
+ 1063-6 + 1063-6 + 1063-6 + 1063-6 + 1063-6 + 1063-6
Adapter
boring Ø x L in mm 17.5 x 80 17.5 x 55 17.5 x 80 17.5 x 55 17.5 x 80 17.5 x 55 17.5 x 80 17.5 x 55 17.5 x 55 17.5 x 80 17.5 x 55 17.5 x 55 17.5 x 55 17.5 x 80 17.5 x 80
vessels per rotor 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6
Cat. No. 2331-6 2333-6 2331-6 2333-6 2331-6 2333-6 2331-6 2333-6 2333-6 2331-6 2333-6 2333-6 2333-6 2331-6 2331-6
Vessels
capacity in ml 4.9 7.5 – 10 10 1.6 – 7 4-7 8.5 – 10 12
Ø x L in mm 13 x 90 15/16 x 75 15 x 102 13/16 x 75 13 x 100 16 x 100 17 x 102
max. RCF 2) 2,254 2,254 2,254 1,807 2,254 2,254 2,254
radius in mm 126 126 126 101 126 126 126
Cat. No. blood collection / urine tubes
+
Adapter
boring Ø x L in mm 17.5 x 80 17.5 x 80 17.5 x 80 17.5 x 55 17.5 x 80 17.5 x 80 17.5 x 80
vessels per rotor 6 6 6 6 6 6 6
Cat. No. 2331-6 2331-6 2331-6 2333-6 2331-6 2331-6 2331-6
2) Please note that the RCF values indicated refer only to rotor performance. The max. permissible RCF of tubes used should be verified with the individual manufacturers.
The max. RCF for glass tubes annotated with footnote 2) is 4,000.
18
EBA 270
PACKAGES
EBA 270 BLOOD TUBE RCF
COMPLETE PACKAGE 1 number of vessels volume (ml) size (mm) RPM
- 1 x EBA 270 centrifuge 2300 6 1.6 - 7 / 100 13 x 75 4,000 1,807
incl. swing-out rotor 6 4 - 10 / 100 13 x 100 4,000 2,254
- 1 x bucket (set), 1-place 2333-6
6 0.5 Pediatric 10,7 x 36 4,000 1,359
- 1 x bucket (set), 1-place 2331-6
- 1 x adapter Pediatric (set), 1-place 1063-6 6 12 (Kova) 17 x 102 4,000 2,254
2300SET1
PRODUCT VIDEOS
Would you like to learn more about this product? Scan the QR Code to visit
our YouTube channel:
www.youtube.com/hettichlabtechnology
19
EBA 280 | 280 S
Simple rotor change for
greater versatility
The EBA 280 and EBA 280 S offer exceptional user comfort and a choice of 6 rotors. The rotor can be removed and repla-
ced easily thanks to the quick release system. The rotor locks in place and remains secure without the use of tools or extra
effort. The backlit digital control panel offers the opportunity to save 9 multiple program settings.
20
EBA 280 | 280 S
TECHNICAL DATA
AVAILABLE ROTORS
SWING-OUT ROTORS angle max. RPM max. capacity Cat. No. page
ANGLE ROTORS
21
EBA 280 | 280 S | SMALL CENTRIFUGES
+
Rotor Bucket
max. RPM EBA 280 | EBA 280 S 4,700 min-1 | 6,000 min-1 Cat. No. 1147-6 (6 pcs.)
max. RCF 3,112 | 5,071
max. capactiy 6 x 15 ml
run up / run down, braked in sec 9 / 11 | 11 / 13
angle | max. noise level 90° | 49 dB (A)
Cat. No. 1146
Vessels
capacity in ml 0.5 1.5 2 4 5 6 15 1.1 – 1.4 2.6 – 3.4 2.7 – 3 4 – 5.5 4.5-5 4.9 7.5 – 10 1.6 – 5
Ø x L in mm 10.7 x 36 11 x 38 11 x 38 10 x 88 12 x 75 12 x 82 17 x 100 8 x 66 13 x 65 11 x 66 15 x 75 11 x 92 13 x 90 15/16 x 92 13 x 75
max. RCF 2) EBA 280 1,877 1,902 1,902 3,112 2,618 2,865 3,112 2,618 2,618 2,618 3,112 3,112 3,112 3,112 2,618
max. RCF 2) EBA 280 S 3,059 3,099 3,099 5,071 4,266 4,669 5,071 4,266 4,266 4,266 5,071 5,071 5,071 5,071 4,266
radius in mm 76 77 77 126 106 116 126 106 106 106 126 126 126 126 106
Cat. No. Pediatric microliter tubes tubes 2) blood collection / urine tubes
+
Adapter
boring Ø x L in mm 11 x 35 11 x 35 11 x 35 17.5 x 80 13.5 x 59 17.5 x 80 17.5 x 80 13.5 x 59 13.5 x 59 13.5 x 59 17.5 x 80 17.5 x 80 17.5 x 80 17.5 x 80 13.5 x 59
vessels per rotor 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6
Cat. No. 1063-6 (6 pcs.) - 1053-6 0767-6 - 1053-6 (6 pcs.) - - - - 1053-6
Vessels
capacity in ml 4 – 7 4 – 7 8.5 – 5 12
Ø x L in mm 16 x 75 13 x 100 16 x 100 17 x 102
max. RCF 2) EBA 280 2,865 3,112 3,112 3,112
max. RCF 2) EBA 280 S 4,669 5,071 5,071 5,071
radius in mm 116 126 126 126
Cat. No. blood collection/ urine tubes
+
Adapter
boring Ø x L in mm 17.5 x 80 13.5 x 79 17.5 x 80 17.5 x 80
vessels per rotor 6 6 6 6
Cat. No. 0767-6 1058 - -
2) Please note that the RCF values indicated refer only to rotor performance. The max. permissible RCF of tubes used should be verified with the individual manufacturers. The max.
RCF for glass tubes annotated with footnote 2) is 4,000.
22
EBA 280 | 280 S
SWING-OUT ROTOR, 8-PLACE | 1148
Rotor
max. RPM | max. RCF 5,000 min-1 | 2,991
max. capactiy 8 x 10 ml
run up | run down, braked in sec 8 | 10
angle | max. noise level 90° | 50 dB (A)
Cat. No. 1148
Vessels
capacity in ml 5 6 10 2.6 – 3.4 2.7 – 3 4 – 5.5 1.6 – 5 4 – 7
Ø x L in mm 12 x 75 12 x 82 17 x 70 13 x 65 11 x 66 15 x 75 13 x 75 16 x 75
max. RCF 2) 2,991 2,991 2,991 2,991 2,991 2,991 2,991 2,991
radius in mm 107 107 107 107 107 107 107 107
Cat. No. tubes 2) blood collection / urine tubes
+
Bucket
boring Ø x L in mm 13 x 53 13 x 53 17.5 x 53 13 x 53 13 x 53 17.5 x 53 13 x 53 17.5 x 53
vessels per rotor 8 8 8 8 8 8 8 8
Cat. No. 1131-A 1131-A 1132-A 1131-A 1131-A 1132-A 1131-A 1132-A
Rotor
max. RPM | max. RCF 5,000 min-1 | 2,963
max. capactiy 12 x 5 ml
run up | run down, braked in sec 10 | 12
angle | max. noise level 60° | 49 dB (A)
Cat. No. 1142
Vessels
capacity in ml 5 2.6 – 3.4 2.7 – 3 1.6 – 5
Ø x L in mm 12 x 75 13 x 65 11 x 66 13 x 75
max. RCF 2) 2,963 2,963 2,963 2,963
radius in mm 106 106 106 106
Cat. No. tube 2) blood collection / urine tubes
+
Bucket 2) Please note that the RCF values indicated
refer only to rotor performance. The max.
boring Ø x L in mm 13.2 x 53 13.2 x 53 13.2 x 53 13.2 x 53 permissible RCF of tubes used should be
vessels per rotor 12 12 12 12 verified with the individual manufacturers.
The max. RCF for glass tubes annotated
Cat. No. 1127-A 1127-A 1127-A 1127-A with footnote 2) is 4,000.
23
EBA 280 | 280 S | SMALL CENTRIFUGES
Rotor
max. RPM | max. RCF 6,000 min-1 | 4,025
max. capactiy 6 x 50 ml
run up | run down, braked in sec 20 | 17
angle | max. noise level 35° | 47 dB (A)
Cat. No. 1137
Vessels
capacity in ml 7 15 25 50 9 – 10 10 1.6 – 5 4 – 7 15 50 30 50
Ø x L in mm 12 x 100 17 x 100 24 x 100 34 x 100 16 x 92 15 x 102 13 x 75 13 x 100 17 x 120 29 x 115 26 x 95 29 x 107
max. RCF 2) 3,944 3,783 3,703 4,025 3,783 3,783 2,978 3,783 3,824 3,824 3,703 3,904
radius in mm 98 94 92 100 94 94 74 94 95 95 92 97
Cat. No. tubes 2) blood collection / urine tubes tubes with screw cap
+
+ 1054-A
Adapter
boring Ø x L in mm 13 x 92 17.5 x 95 26 x 88 35 x 96 17.5 x 95 17.5 x 95 17.5 x 95 17.5 x 95 17 x 98 30 x 98 26 x 88 29 x 95
vessels per rotor 18 6 6 6 6 6 6 6 6 3 6 6
Cat. No. 1632 1635 1633 - 1635 1635 1635 1635 1631 1641 1633 1634
Rotor
max. RPM | max. RCF 5,000 min-1 | 2,879
max. capactiy 12 x 7 ml
run up | run down, braked in sec 8 | 10
angle | max. noise level 35° | 51 dB (A)
Cat. No. 1133
Vessels
capacity in ml 5 6 7
Ø x L in mm 12 x 75 12 x 82 12 x 100
max. RCF 2) 2,879 2,879 2,879
radius in mm 103 103 103
Cat. No. tubes 2)
+
Adapter
What makes the 1133 rotor special is
its adapters with a decanting aid. The
decanting aid firmly holds the tube
and keeps it from falling out when the
boring Ø x L in mm 12.5 x 66 12.5 x 66 12.5 x 66 supernatant is decanted. The 1133
vessels per rotor 12 12 12 rotor is often used in blood typing
serology.
Cat. No. - - -
2) Please note that the RCF values indicated refer only to rotor performance. The max. permissible RCF of tubes used should be verified with the individual manufacturers. The max.
RCF for glass tubes annotated with footnote 2) is 4,000.
24
EBA 280 | 280 S
ANGLE ROTOR, 12-PLACE | 1139
Rotor
max. RPM | max. RCF 6,000 min-1 | 4,146
max. capactiy 12 x 15 ml
run up | run down, braked in sec 16 | 16
angle | max. noise level 35° | 50 dB (A)
Cat. No. 1139
Vessels
capacity in ml 0.5 1.5 2 5 6 15 1.1 – 1.4 2.6 – 3.4 2.7 – 3 4.5 – 5 4.9 7.5 – 10 10 1.6 – 5 4 – 7
Ø x L in mm 10.7 x 36 11 x 38 11 x 38 12 x 75 12 x 82 17 x 100 8 x 66 13 x 65 11 x 66 11 x 92 13 x 90 15/16 x 92 15 x 102 13 x 75 13 x 100
max. RCF 2) 2,777 2,737 2,737 3,300 3,300 4,146 3,300 3,300 3,300 4,146 4,146 4,146 4,146 3,300 4,146
radius in mm 69 68 68 82 82 103 82 82 82 103 103 103 103 82 103
Cat. No. Pediatric microliter tubes tubes 2) blood collection / urine tubes
+
Adapter
boring Ø x L in mm 11 x 35 11 x 35 11 x 35 13.5 x 60 13.5 x 60 17.7 x 88 13.5 x 60 13.5 x 60 13.5 x 60 17.7 x 88 17.7 x 88 17.7 x 88 17.7 x 88 13.5 x 60 13.5 x 79
vessels per rotor 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12
Cat. No. 1063-6 (6 pcs.) 1054-A - 1054-A - - - - 1054-A 1058
Vessels
capacity in ml 8 8.5 – 10 12 5 15
Ø x L in mm 16 x 125 16 x 100 17 x 102 17 x 59 17 x 120
max. RCF 2) 4,146 4,146 4,146 3,180 4,146
radius in mm 103 103 103 79 103
Cat. No. blood collection / urine tubes - -
+
Adapter
boring Ø x L in mm 17.7 x 88 17.7 x 88 17.7 x 88 17 x 25 17.7 x 88
vessels per rotor 6 12 6 12 6
Cat. No. - - - 1064 -
2) Please note that the RCF values indicated refer only to rotor performance. The max. permissible RCF of tubes used should be verified with the individual manufacturers. The max.
RCF for glass tubes annotated with footnote 2) is 4,000.
25
EBA 280 | 280 S | SMALL CENTRIFUGES
PACKAGES
EBA 280 SEROLOGY PACKAGE 1 number of vessels volume (ml) size (mm) RPM RCF
- 1 x EBA 280 centrifuge 1101 12 1.6 - 5 11 / 12 / 13 x 75 5,000 2,963
- 1 x swing-out rotor, 12-place 1142
- 12 x bucket 1127-A
1101SET1
EBA 280 BLOOD TUBE PACKAGE 2 number of vessels volume (ml) size (mm) RPM RCF
- 1 x EBA 280 centrifuge 1101 6 1.6 - 5 13 x 75 4,700 2,618
- 1 x swing-out rotor, 6-place 1146 6 4-7 13 x 100 4,700 3,112
- 1 x bucket (set) 1147-6
6 4-7 16 x 75 4,700 2,865
- 1 x adapter (set), 1-place 1053-6
- 6 x adapter, 1-place 1058 6 8.5 - 10 16 x 100 4,700 3,112
- 1 x spacer (set) 0767-6
1101SET2
EBA 280 BLOOD TUBE PACKAGE 3 number of vessels volume (ml) size (mm) RPM RCF
- 1 x EBA 280 centrifuge 1101 12 1.6 - 5 13 x 75 6,000 3,300
- 1 x angle rotor, 12-place 1139 12 4-7 13 x 100 6,000 3,300
- 12 x adapter, 1-place 1059
12 4 - 10 16 x 75 6,000 4,146
- 12 x adapter, 1-place 1058
12 8.5 - 10 16 x 100 6,000 4,146
1101SET3
EBA 280 BLOOD TUBE PACKAGE 4 number of vessels volume (ml) size (mm) RPM RCF
- 1 x EBA 280 centrifuge 1101 8 1.6 - 5 13 x 75 5,000 2,991
- 1 x swing-out rotor, 8-place 1148 8 4-7 16 x 75 5,000 2,991
- 8 x bucket 1131-A
- 8 x bucket 1132-A
1101SET4
1101SET5
EBA 280 S BLOOD TUBE PACKAGE 1 number of vessels volume (ml) size (mm) RPM RCF
- 1 x EBA 280 S centrifuge 1102 6 1.6 - 5 13 x 75 6,000 4,266
- 1 x angle rotor, 6-place 1146 6 4-7 13 x 100 6,000 5,071
- 1 x bucket (set) 1147-6
6 4-7 16 x 75 6,000 4,699
- 1 x adapter (set) 1053-6
- 6 x adapter, 1-place 1058 6 8.5 - 10 16 x 100 6,000 5,071
- 1 x spacer (set) 0767-6
1102SET1
26
EBA 280 | 280 S
PRODUCT VIDEOS
Would you like to learn more about this product? Scan the QR Code to visit
our YouTube channel:
www.youtube.com/hettichlabtechnology
27
HAEMATOKRIT 200
Haematokrit determination
in just 7 minutes
The HAEMATOKRIT 200 is a fast and efficient centrifuge for determining hematocrit count. It runs at 13,000 RPM and
accommodates up to 24 capillary tubes to a maximum RCF of 16,060. Results can be clearly viewed with the integrated
Haematocrit reader in the rotor lid.
28
HAEMATOKRIT 200
TECHNICAL DATA
HAEMATOKRIT 200
voltage *) 200 – 240 V 1 ~
frequency 50 – 60 Hz
consumption 270 VA
emission, immunity EN / IEC 61326-1, class B
max. capacity 24 capillaries
max. RPM 13,000 min-1
max. RCF 16,060
running time 1 – 99 min, continuous run, short cycle mode (impulse button)
dimensions (W x D x H) 261 x 353 x 228 mm
weight approx. 10 kg
max. noise level ≤ 56 dB (A)
Cat. No. 1801
AVAILABLE ROTOR
Rotor
max. RPM | max. RCF 13,000 min-1 | 16,060
max. capacity 24 capillaries
run up | run down, braked in sec 9 | 16
angle | max. noise level 90° | 56 dB (A)
measuring lid inclusive
Cat. No. INCLUSIVE
Capillaries
Standard
max. RCF 2) 16,060
radius in mm 85
Cat. No. -
+
HOLDING TRAYS
The holding trays in rotor
2076 are easy to clean and
Adapter disposable in the case of glass
boring Ø x L in mm - breakage.
capillaries per rotor 24
Cat. No. -
2) Please note that the RCF values indicated refer only to rotor performance. The max. permissible RCF of tubes used should be verified with the individual manufacturers. The max.
RCF for glass tubes annotated with footnote 2) is 4,000.
29
MICROLITER CENTRIFUGES
Powerful results at the micro level
32
TECHNICAL DATA
MIKRO 185
MIKRO 185
voltage *) 200 – 240 V 1 ~
frequency 50 – 60 Hz
consumption 330 VA
emission, immunity EN / IEC 61326-1, class B
max. capacity 24 x 1.5 / 2.0 ml
max. RPM 14,000 min -1
max. RCF 18,845
running time 1 – 99 min: 59 s, continuous run, short cycle mode (impulse button)
dimensions (W x D x H) 261 x 353 x 228 mm
weight approx. 11 kg
noise level ≤ 54 dB (A) with rotor 1252-A
Cat. No. 1203
AVAILABLE ROTORS
ANGLE ROTORS angle max. RPM max. capacity Cat. No. page
PRODUCT VIDEOS
Would you like to learn more about this product? Scan the QR Code to visit
our YouTube channel:
www.youtube.com/hettichlabtechnology
33
MIKRO 185 | MICROLITER CENTRIFUGES
+
Rotor Lid bioseal 5)
max. RPM | max. RCF 14,000 min | 18,845
-1
Cat. No. INCLUSIVE
max. capactiy 24 x 2 ml
run up | run down, braked in sec 15 | 15
angle | max. noise level 45° | 59 dB (A)
Cat. No. 1226-A
Vessels
capacity in ml 0.2 0.4 0.5 0.8 1.5 2.0 0.5
Ø x L in mm 6 x 18 6 x 45 8 x 30 8 x 45 11 x 38 11 x 38 10.7 x 36
max. RCF 2) 18,845 18,845 18,845 18,845 18,845 18,845 17,749
radius in mm 86 86 86 86 86 86 81
Cat. No. microliter tubes Pediatric
+
Adapter
boring Ø x L in mm 6 x 40 6 x 40 8 x 40 8 x 40 - 11.2 x 39 11.2 x 39
vessels per rotor 24 24 24 24 24 24 24
Cat. No. 2024 2024 2023 2023 20317) - 0788
+
Rotor Lid
max. RPM | max. RCF 14,000 min-1 | 15,558 Cat. No. INCLUSIVE
max. capactiy 12 x 2 ml
run up | run down, braked in sec 15 | 15
angle | max. noise level 45° | 54 dB (A)
Cat. No. 1252-A
Vessels
capacity in ml 0.2 0.4 0.5 0.8 1.5 2.0 0.5
Ø x L in mm 6 x 18 6 x 45 8 x 30 8 x 45 11 x 38 11 x 38 10.7 x 36
max. RCF 2) 15,558 15,558 15,558 15,558 15,558 15,558 14,462
radius in mm 71 71 71 71 71 71 66
Cat. No. microliter tubes Pediatric
+
2) Please note that the RCF values indicated
refer only to rotor performance. The max.
permissible RCF of tubes used should be
verified with the individual manufacturers.
The max. RCF for glass tubes annotated with
Adapter footnote 2) is 4,000.
boring Ø x L in mm 6 x 40 6 x 40 8 x 40 8 x 40 - 11.2 x 39 11.2 x 39 5) Tested by the TÜV in conformity with DIN EN
61010, section 2 - 020.
vessels per rotor 12 12 12 12 12 12 12
7) For centrifugation at high speeds, we
Cat. No. 2024 2024 2023 2023 20317) - 0788 recommend to use conical, phenol-resistant
adapters 2031.
34
ANGLE ROTOR, 18-PLACE | 1258-A
MIKRO 185
+
Rotor Lid
max. RPM | max. RCF 14,000 min-1 | 16,654 Cat. No. INCLUSIVE
max. capactiy 18 x 2 ml
run up | run down, braked in sec 15 | 15
angle | max. noise level 45° | 56 dB (A)
Cat. No. 1258-A
Vessels
capacity in ml 0.2 0.4 0.5 0.8 1.5 2.0 0.5
Ø x L in mm 6 x 18 6 x 45 8 x 30 8 x 45 11 x 38 11 x 38 10.7 x 36
max. RCF 2) 16,654 16,654 16,654 16,654 16,654 16,654 15,558
radius in mm 76 76 76 76 76 76 71
Cat. No. microliter tubes Pediatric
+
Adapter
boring Ø x L in mm 6 x 40 6 x 40 8 x 40 8 x 40 - 10.2 x 19 11.2 x 39
vessels per rotor 18 18 18 18 18 18 9
Cat. No. 2024 2024 2023 2023 20317) - 0788
+
Rotor Lid bioseal 5)
max. RPM | max. RCF 14,000 min-1 | 16,654 Cat. No. INCLUSIVE
max. capactiy 18 x 2 ml
run up | run down, braked in sec 16 | 15
angle | max. noise level 45° | 57 dB (A)
Cat. No. 1213-A
Vessels
capacity in ml 0.2 0.4 0.5 0.8 1.5 2.0 1.5 2.0
Ø x L in mm 6 x 18 6 x 45 8 x 30 8 x 45 11 x 38 11 x 38 11 x 38 11 x 38
max. RCF 2) 16,654 16,654 16,654 16,654 16,654 16,654 16,654 16,654
radius in mm 76 76 76 76 76 76 76 76
micro spin
Cat. No. microliter tubes
+
columns 2) Please note that the RCF values indicated
refer only to rotor performance. The max.
permissible RCF of tubes used should be
verified with the individual manufacturers.
The max. RCF for glass tubes annotated with
Adapter footnote 2) is 4,000.
boring Ø x L in mm 6 x 40 6 x 40 8 x 40 8 x 40 10.2 x 19.3 11.2 x 39 10.2 x 19.3 11.2 x 39 5) Tested by the TÜV in conformity with DIN EN
61010, section 2 - 020.
vessels per rotor 18 18 18 18 18 18 18 18
7) For centrifugation at high speeds, we
Cat. No. 2024 2024 2023 2023 20317) - 20317) - recommend to use conical, phenol-resistant
adapters 2031.
35
MIKRO 200 | 200 R
Faster results in molecular biology
The MIKRO 200 and MIKRO 200 R are amongst the highest-speed microliter centrifuges in their class. Rotors are designed
to spin microliter and PCR tubes. MIKRO 200 achieves a maximum RCF of 21,382 with up to 30 tubes, enabling rapid
processing of samples and optimal separation, at low noise levels of 54 dB(A). This unit is available with refrigeration and a
temperature range from -10 °C to +40 °C (MIKRO 200 R).
36
MIKRO 200 | 200 R
TECHNICAL DATA
MIKRO 200 MIKRO 200 R
non-refrigerated refrigerated
voltage *) 200 – 240 V 1 ~ 200 – 240 V 1 ~
frequency 50 – 60 Hz 50 Hz
consumption 240 VA 450 VA
emission, immunity EN / IEC 61326-1, class B EN / IEC 61326-1, class B
max. capacity 30 x 1.5 / 2.0 ml 30 x 1.5 / 2.0 ml
max. RPM 15,000 min-1 15,000 min-1
max. RCF 21,382 21,382
running time 1 – 99 min: 59 s, continuous run, 1 – 99 min: 59 s, continuous run,
short cycle mode (impulse button) short cycle mode (impulse button)
dimesions (W x D x H) 275 x 344 x 260 mm 281 x 553 x 260 mm
weight approx. 11.5 kg approx. 28 kg
noise level ≤ 58 dB (A) with rotor 2434 ≤ 51 dB (A) with rotor 2437
temperature control, infinitely variable - from -10 to +40 °C
Cat. No. 2400 2405
AVAILABLE ROTORS
ANGLE ROTORS angle max. RPM max. capacity Cat. No. page
45° inside /
angle rotor, 30-place 15,000 min-1 30 x 2 ml 2437 38
55° outside
37
MIKRO 200 | 200 R | MICROLITER CENTRIFUGES
Rotor
max. RPM | max. RCF
max. capactiy
15,000 min | 21,382
-1
24 x 2 ml
+ Lid bioseal 5)
Cat. No. INCLUSIVE
Vessels
capacity in ml 0.2 0.4 0.5 0.8 1.5 2.0 0.5
Ø x L in mm 6 x 18 6 x 45 8 x 30 8 x 45 11 x 38 11 x 38 10.7 x 36
max. RCF 2) 21,382 21,382 21,382 21,382 21,382 21,382 20,376
radius in mm 85 85 85 85 85 85 81
Cat. No. microliter tubes Pediatric
+
Adapter
boring Ø x L in mm 6 x 40 6 x 40 8 x 40 8 x 40 - 11.2 x 42.6 11.2 x 39
vessels per rotor 24 24 24 24 24 24 12
Cat. No. 2024 2024 2023 2023 20317) - 0788
Rotor
max. RPM | max. RCF
max. capactiy
15,000 min | 21,382
-1
30 x 2 ml
+ Lid bioseal 5)
Cat. No. INCLUSIVE
Vessels
capacity in ml 0.2 0.4 0.5 0.8 1.5 2.0 0.5
Ø x L in mm 6 x 18 6 x 45 8 x 30 8 x 45 11 x 38 11 x 38 10.7 x 36
max. RCF 2) 21,382 21,382 21,382 21,382 21,382 21,382 20,376 1) For cooled versions: Lowest temperature
radius in mm 85 85 85 85 85 85 81 achievable with precooling and max. speed.
2) Please note that the RCF values indicated
Cat. No. microliter tubes Pediatric
+
refer only to rotor performance. The max. per-
missible RCF of tubes used should be verified
with the individual manufacturers. The max.
RCF for glass tubes annotated with footnote
2) is 4,000.
Adapter 5) Tested by the TÜV in conformity with DIN EN
boring Ø x L in mm 6 x 40 6 x 40 8 x 40 8 x 40 - 11.2 x 41.3 11.2 x 39 61010, section 2 - 020.
vessels per rotor 30 30 30 30 30 30 15 7) For centrifugation at high speeds, we
recommend to use conical, phenol-resistant
Cat. No. 2024 2024 2023 2023 20317) - 0788 adapters. Cat. No. 2031.
38
MIKRO 200 | 200 R
ANGLE ROTOR, 24-PLACE | 2428
Rotor
max. RPM | max. RCF
max. capactiy
15,000 min | 21,382
-1
24 x 2 ml
+ Lid bioseal 5)
Cat. No. INCLUSIVE
Vessels
capacity in ml 0.2 0.4 0.5 0.8 1.5 2.0 1.5 2.0 0.5
Ø x L in mm 6 x 18 6 x 45 8 x 30 8 x 45 11 x 38 11 x 38 11 x 38 11 x 38 10.7 x 36
max. RCF 2) 21,382 21,382 21,382 21,382 21,382 21,382 21,382 21,382 20,376
radius in mm 85 85 85 85 85 85 85 85 81
micro spin
Cat. No. microliter tubes Pediatric
+
columns
Adapter
boring Ø x L in mm 6 x 40 6 x 40 8 x 40 8 x 40 - 10.2 x 19 - 11.2 x 42.6 11.2 x 39
vessels per rotor 24 24 24 24 24 24 24 24 12
Cat. No. 2024 2024 2023 2023 20317) - 20317) - 0788
Rotor
max. RPM | max. RCF
max. capactiy
15,000 min-1 | 14,338
4 x 8 PCR strips
+ Lid
Cat. No. E3243
Vessels
capacity in ml 0.2 0.2
Ø x L in mm 6 x 18 -
max. RCF 2) 14,338 14,338 1) For cooled versions: Lowest temperature
achievable with precooling and max. speed.
radius in mm 57 57
PCR
2) Please note that the RCF values indicated
Cat. No. - refer only to rotor performance. The max. per-
+
strips
missible RCF of tubes used should be verified
with the individual manufacturers. The max.
RCF for glass tubes annotated with footnote
2) is 4,000.
Adapter 5) Tested by the TÜV in conformity with DIN EN
boring Ø x L in mm 6.5 x 15.5 6.5 x 15.5 61010, section 2 - 020.
7) For centrifugation at high speeds, we
vessels per rotor 32 4x8 recommend to use conical, phenol-resistant
Cat. No. - - adapters. Cat. No. 2031.
39
MIKRO 200 | 200 R | MICROLITER CENTRIFUGES
PACKAGES
MIKRO 200 number of
MICROLITER TUBES PACKAGE 1 vessels volume (ml) size (mm) RPM RCF
- 1 x MIKRO 200 2400 24 0.2 - 2.0 11 x 38 15,000 21,382
- 1 x angle rotor 24-place, incl. lid bioseal 2434 24 0.5 10.7 x 36 15,000 20,376
2400SET1
2400SET2
2405SET1
2405SET2
2405SET3
40
MIKRO 200 | 200 R
DID YOU KNOW?
The Download Center on our website allows you to access the most up to date
documents including catalogs, brochures, data sheets and certificates.
Try it now: www.hettichlab.com/downloadcenter
41
MIKRO 220 | 220 R
Fast and flexible
The MIKRO 220 spins at an unmatched speed of 18,000 RPM and delivers an RCF of 31,514 in just 26 seconds. Ultimate
flexibility is provided by a choice of 7 different rotors from 0.2 ml microliter tubes to 50 ml conical tubes, allowing for nume-
rous research applications on a single machine. This unit is available with refrigeration and a temperature range from -20 °C
to +40 °C (MIKRO 220 R).
42
MIKRO 220 | 220 R
TECHNICAL DATA
MIKRO 220 MIKRO 220 R
non-refrigerated refrigerated
voltage *) 200 – 240 V 1 ~ 200 – 240 V 1 ~
frequency 50 – 60 Hz 50 Hz
consumption 510 VA 850 VA
emission, immunity EN / IEC 61326-1, class B EN / IEC 61326-1, class B
max. capacity 48 x 1.5 / 2.0 ml, 6 x 50 ml 48 x 1.5 / 2.0 ml, 6 x 50 ml
max. RPM 18,000 min-1 18,000 min-1
max. RCF 31,514 31,514
running time 1 – 99 min: 59 s, continuous run, 1 – 99 min: 59 s, continuous run,
short cycle mode (impulse button) short cycle mode (impulse button)
dimensions (W x D x H) 330 x 420 x 313 mm 330 x 650 x 313 mm
weight approx. 21 kg approx. 42 kg
noise level ≤ 58 dB (A) with rotor 1189-A ≤ 59 dB (A) with rotor 1016
temperatur control, infinitely variable - from -20 to +40 °C
Cat. No. 2200 2205
AVAILABLE ROTORS
SWING-OUT ROTORS angle max. RPM max. capacity Cat. No. page
ANGLE ROTOR
43
MIKRO 220 | 220 R | MICROLITER CENTRIFUGES
Rotor
max. RPM | max. RCF
max. capacity
18,000 min-1 | 31,514
24 x 2 ml
+ Lid bioseal 5)
Cat. No. INCLUSIVE
Vessels
capacity in ml 0.2 0.4 0.5 0.8 1.5 2.0 0.5
Ø x L in mm 6 x 18 6 x 45 8 x 30 8 x 45 11 x 38 11 x 38 10.7 x 36
max. RCF 2) 31,514 31,514 31,514 31,514 31,514 31,514 30,065
radius in mm 87 87 87 87 87 87 83
Cat. No. microliter tubes Pediatric
+
Adapter
boring Ø x L in mm 6 x 40 6 x 40 8 x 40 8 x 40 10.2 x 19.3 11.2 x 40.8 11.2 x 39
vessels per rotor 24 24 24 24 24 24 12
Cat. No. 2024 2024 2023 2023 20317) - 0788
Rotor
max. RPM | max. RCF
max. capacity
14,000 min | 21,255
-1
30 x 2 ml
+ Lid bioseal 5)
Cat. No. INCLUSIVE
Vessels
capacity in ml 0.2 0.4 0.5 0.8 1.5 2.0 0.5
Ø x L in mm 6 x 18 6 x 45 8 x 30 8 x 45 11 x 38 11 x 38 10.7 x 36
max. RCF 2) 21,255 21,255 21,255 21,255 21,255 21,255 20,379 1) For cooled versions: Lowest temperature
radius in mm 97 97 97 97 97 97 93 achievable with precooling and max. speed.
2) Please note that the RCF values indicated
Cat. No. microliter tubes Pediatric
+
refer only to rotor performance. The max.
permissible RCF of tubes used should be
verified with the individual manufacturers.
The max. RCF for glass tubes annotated with
footnote 2) is 4,000.
Adapter 5) Tested by the TÜV in conformity with DIN EN
boring Ø x L in mm 6 x 40 6 x 40 8 x 40 8 x 40 10.2 x 19.3 11.2 x 40.9 11.2 x 39 61010, section 2 - 020.
7) For centrifugation at high speeds, we
vessels per rotor 30 30 30 30 30 30 15
recommend to use conical, phenol-
Cat. No. 2024 2024 2023 2023 20317) - 0788 resistant adapters. Cat. No. 2031.
44
MIKRO 220 | 220 R
ANGLE ROTOR, 48-PLACE | 1158-L
Rotor
max. RPM
max. RCF
14,000 min -1
max. capacity 48 x 2 ml
run-up | run-down, braked in sec 21 | 22
angle | max. noise level 45° | 59 dB (A)
temperature in °C1) -4
Cat. No. 1158-L
Vessels
capacity in ml 0.2 0.4 0.5 0.8 1.5 2.0
Ø x L in mm 6 x 18 6 x 45 8 x 30 8 x 45 11 x 38 11 x 38
21,255 / 21,255 / 21,255 / 21,255 / 21,255 / 21,255 /
max. RCF 2) outside / inside 18,845 18,845 18,845 18,845 18,845 18,845
radius in mm outside / inside 97 / 86 97 / 86 97 / 86 97 / 86 97 / 86 97 / 86
Cat. No. microliter tubes
+
Adapter
boring Ø x L in mm 6 x 40 6 x 40 8 x 40 8 x 40 10.2 x 19.3 11.4 x 39
vessels per rotor 48 48 48 48 48 48
Cat. No. 2024 2024 2023 2023 20317) -
Rotor
max. RPM | max. RCF
max. capacity
13,000 min-1 | 18,516
24 x 2 ml
+ Lid bioseal 5)
Cat. No. INCLUSIVE
Vessels
capacity in ml 0.2 0.4 0.5 0.8 1.5 2.0
Ø x L in mm 6 x 18 6 x 45 8 x 30 8 x 45 11 x 38 11 x 38
max. RCF 2) 18,516 18,516 18,516 18,516 18,516 18,516
1) For cooled versions: Lowest temperature
radius in mm 98 98 98 98 98 98 achievable with precooling and max. speed.
Cat. No. microliter tubes 2) Please note that the RCF values indicated
+
refer only to rotor performance. The max.
permissible RCF of tubes used should be
verified with the individual manufacturers.
The max. RCF for glass tubes annotated with
footnote 2) is 4,000.
Adapter
5) Tested by the TÜV in conformity with DIN EN
boring Ø x L in mm 6 x 40 6 x 40 8 x 40 8 x 40 10.2 x 19.3 11.5 x 38.5 61010, section 2 - 020.
vessels per rotor 24 24 24 24 24 24 7) For centrifugation at high speeds, we
recommend to use conical, phenol-
Cat. No. 2024 2024 2023 2023 20317) - resistant adapters. Cat. No. 2031.
45
MIKRO 220 | 220 R | MICROLITER CENTRIFUGES
Rotor
max. RPM | max. RCF 6,000 min-1 | 4,025
max. capacity 6 x 50 ml
run-up | run-down, braked in sec 14 | 17
angle | max. noise level 35° | 59 dB (A)
temperature in °C1) -20
Cat. No. 1016
Vessels
capacity in ml 7 15 25 50 9-10 10 1.6 – 5 4 – 7 5 15 50 30 50
Ø x L in mm 12 x 100 17 x 100 24 x 100 34 x 100 16 x 92 15 x 102 13 x 75 13 x 100 17 x 59 17 x 120 29 x 115 26 x 95 29 x 107
max. RCF 2) 3,944 3,783 3,703 4,025 3,783 3,783 2,978 3,783 3,622 3,824 3,824 3,703 3,904
radius in mm 98 94 92 100 94 94 74 94 90 95 95 92 97
Cat. No. tubes 2) blood collection / urine tubes - tubes with screw cap
+
+ 1054-A
Adapter
boring Ø x L in mm 13 x 92 17.5 x 95 26 x 88 35 x 96 17.5 x 95 17 x 51 17.5 x 95 17.5 x 95 17 x 51 17 x 98 30 x 98 26 x 88 29 x 95
vessels per rotor 18 6 6 6 6 6 6 6 6 6 3 6 6
Cat. No. 1632 1635 1633 - 1635 1635 1635 1635 1649 1631 1641 1633 1634
Rotor
max. RPM | max. RCF
max. capacity
13,000 min-1 | 14,171
60 x 2 ml
+ Lid
Cat. No. INCLUSIVE
Vessels
capacity in ml 0.2 0.4 0.5 0.8 1.5 2.0
Ø x L in mm 6 x 18 6 x 45 8 x 30 8 x 45 11 x 38 11 x 38
max. RCF 2) 14,171 14,171 14,171 14,171 14,171 14,171
radius in mm 75 75 75 75 75 75
Cat. No. microliter tubes
+
Adapter
1)
2)
For cooled versions: Lowest temperature
achievable with precooling and max.
speed.
Please note that the RCF values indicated
refer only to rotor performance. The max.
boring Ø x L in mm 6 x 40 6 x 40 8.4 x 43 8.4 x 43 10.8 x 37 10.8 x 37 permissible RCF of tubes used should be
vessels per rotor 192 192 126 126 60 60 verified with the individual manufacturers.
The max. RCF for glass tubes annotated
Cat. No. 1378 1378 1379 1379 1377 1377 with footnote 2) is 4,000.
46
MIKRO 220 | 220 R
ANGLE ROTOR, 12-PLACE | 1015
Rotor
max. RPM | max. RCF 6,000 min-1 | 4,146
max. capacity 12 x 15 ml
run-up | run-down, braked in sec 14 | 16
angle | max. noise level 35° | 60 dB (A)
temperature in °C1) -20
Cat. No. 1015
Vessels
capacity in ml 5 15 1.1 – 1.4 2.6 – 3.4 2.7 – 3 4.5 – 5 4.9 7.5 – 8.5 9 – 10 10 1.6 – 5 4-7 8.5 – 10 5 15
Ø x L in mm 12 x 75 17 x 100 8 x 66 13 x 65 11 x 66 11 x 92 13 x 90 15 x 92 16 x 92 15 x 102 13 x 75 13 x 100 16 x 100 17 x 59 17 x 120
max. RCF 2) 3,300 4,146 3,300 3,300 3,300 4,146 4,146 4,146 4,146 4,146 3,300 4,146 4,146 3,180 4,146
radius in mm 82 103 82 82 82 103 103 103 103 103 82 103 103 79 103
Cat. No. tubes 2) blood collection / urine tubes - -
+
Adapter
boring Ø x L in mm 13.5 x 60 17.7 x 88 13.5 x 60 13.5 x 60 13.5 x 60 17.7 x 88 17.7 x 88 17.7 x 88 17.7 x 88 17.7 x 88 13.5 x 60 13.5 x 79 17.7 x 88 17 x 25 17.7 x 88
vessels per rotor 12 12 12 12 12 12 12 12 12 12 12 12 12 12 6
Cat. No. 1054-A - 1054-A 1054-A 1054-A - - - - - 1054-A 1058 - 1064 -
Rotor
max. RPM | max. RCF
max. capactiy
14,000 min-1 | 18,845
6 x 8 PCR strips
+ Lid
Cat. No. 1162
Vessels
capacity in ml 0.2 0.2
Ø x L in mm 6 x 18 -
max. RCF 2) 18,845 18,845
radius in mm 86 86
PCR
Cat. No. -
+
strips
47
MIKRO 220 | 220 R | MICROLITER CENTRIFUGES
PACKAGES
MIKRO 220 number of
MICROLITER TUBES PACKAGE 1 vessels volume (ml) size (mm) RPM RCF
- 1 x MIKRO 220 2200 24 0.2 - 2.0 11 x 38 18,000 31,514
- 1 x angle rotor 24-place, incl. lid bioseal 1195-A 24 0.5 10.7 x 36 18,000 30,065
2200SET1
2200SET2
2205SET1
2205SET2
48
DID YOU KNOW?
The Download Center on our website allows you to access the most up to date
documents including catalogs, brochures, data sheets and certificates.
Try it now: www.hettichlab.com/downloadcenter
49
BENCHTOP CENTRIFUGES
Specialists in diversity
For decades, the ROTOFIX 32 A has set the standard in daily lab routine thanks to its versatility and solid construction. The
benchtop centrifuge spins sample volumes up to 6 x 94 ml, 40 blood collection tubes or 8 x 50 ml conical tubes with a simple
user interface. Hettich’s cytology rotors are compatible with most existing funnel/slide systems and have bio-containment lids.
52
TECHNICAL DATA
ROTOFIX 32 A
voltage *) 208 – 240 V 1 ~
frequency 50 – 60 Hz
consumption 300 VA
ROTOFIX 32 A
emission, immunity EN / IEC 61326-1, class B
max. capacity 4 x 100 ml / 6 x 94 ml
max. RPM 6,000 min-1
max. RCF 4,226
running time 1– 99 min, continuous run, short cycle mode (impulse button)
dimesions (W x D x H) 366 x 430 x 257 mm
weight approx. 23 kg
noise level 52 dB (A) with rotor 1628
Cat. No. 1206
AVAILABLE ROTORS
SWING-OUT ROTORS angle max. RPM max. capacity Cat. No. page
swing-out rotor, 12-place 55° / 60° / 80° 4,000 min-1 12 x 15 ml 1628 60
ANGLE ROTORS
53
ROTOFIX 32 A | BENCHTOP CENTRIFUGES
Rotor
max. RPM | max. RCF 4,000 min-1 | 2,451
max. capacity 4 x 50 ml
run-up | run-down, braked in sec 22 | 25
angle | max. noise level 90° | 55 dB (A)
Cat. No. 1624
Vessels
capacity in ml 5 5 6 7 9 9 15 15 20 25 45 50
Ø x L in mm 12 x 75 12 x 75 12 x 82 12 x 100 14 x 100 14 x 100 17 x 100 17 x 100 21 x 100 24 x 100 31 x 100 34 x 100
max. RCF 2) 2,057 2,164 2,308 2,308 2,308 2,415 2,308 2,451 2,361 2,451 2,361 2,451
radius in mm 115 121 129 129 129 135 129 137 132 137 132 137
Cat. No. tubes 2)
+
with with with + 0701
decanting aid decanting aid decanting aid
Carrier
boring Ø x L in mm 12.5 x 64.4 13.5 x 65 12.5 x 71.5 12.5 x 71.5 14.6 x 74 14.6 x 78 17.6x71.5 17.6 x 78 21.5 x 74 26 x 78 32 x 74 35 x 78
vessels per rotor 16 68 16 16 20 40 16 28 8 8 4 4
Cat. No. 1369-91 1372 1369-92 1369-92 1370 1741 1369 1742 1346 1745 1345 1746
Vessels
capacity in ml 1.1–1.4 2.6–3.4 4–5.5 4.9 1.6 – 5 4–7 1.6 – 5 4–7 4–7 4–7 4–7 8.5 – 10 30 1 – 8
Ø x L in mm 8 x 66 13 x 65 15 x 75 13 x 90 13 x 75 16 x 75 13 x 75 16 x 75 13 x 100 13 x 100 13 x 100 16 x 100 26 x 95 simple / multiple
max. RCF 2) 2,415 2,325 2,325 2,451 2,129 2,361 2,325 2,325 2,361 2,361 2,451 2,451 2,451 1,646
radius in mm 135 130 130 137 119 132 130 130 132 132 137 137 137 92
Cat. No. blood collection / urine vessels - cyto chambers
+
+ 0701 + 0716 + 0716 + 0768 16) + 0716 + 0716 + 1058
Carrier
boring Ø x L in mm 14.6 x 78 17.6 x 78 17.6 x 78 14.6 x 78 14.6 x 78 17.6x71.5 17.6 x 78 17.6 x 78 17.6x71.5 14.6 x 74 13.5 x 78 17.6x71.5 26 x 78 -
vessels per rotor 40 28 28 40 40 16 28 28 16 20 28 16 8 4
Cat. No. 1741 1742 1742 1741 1741 1369 4) 1742 1742 1369 4) 1370 4) 1739 1369 4) 1745 1660
2) Please note that the RCF values indicated refer only to rotor performance. The max. permissible RCF of tubes used should be verified with the individual manufacturers.
The max. RCF for glass tubes annotated with footnote 2) is 4,000.
4) Please remove the spacer.
16) Packed in units of 10 pieces.
20) Vacutainers made of glass may not be used.
54
SWING-OUT ROTOR, 4-PLACE | 1624
+
Rotor Bucket
max. RPM | max. RCF 4,000 min-1 | 1,968 Cat. No. 1366
ROTOFIX 32 A
max. capacity 48 x 4 ml
run-up | run-down, braked in sec 22 | 25
angle | max. noise level 90° | 56 dB (A)
Cat. No. 1624
Vessels
capacity in ml 1.5 2.0 1 3 4
Ø x L in mm 11 x 38 11 x 38 6 x 45 10 x 60 12 x 60
max. RCF 2) 1,968 1,968 1,950 1,932 1,932
radius in mm 110 110 109 108 108
Cat. No. microliter tubes Rhesus tubes 2)
+
Adapter
boring Ø x L in mm 11.5 x 38 11.5 x 38 6.5 x 23 10.5 x 23 12.5 x 44
vessels per rotor 36 36 120 48 48
Cat. No. 5277 5277 1357 1327 1326
+
Rotor Bucket
max. RPM | max. RCF 4,000 min-1 | 2,665 Lid bioseal 5) 1492
max. capacity 4 x 100 ml Cat. No. 1481
run-up | run-down, braked in sec 22 | 25
angle | max. noise level 90° | 55 dB (A)
Cat. No. 1624
Vessels
capacity in ml 0,5 1,5 2,0 1 3 5 6 7 9 15 25 50 94 100
Ø x L in mm 10.7 x 36 11 x 38 11 x 38 6 x 45 10 x 60 12 x 75 12 x 82 12 x 100 14 x 100 17 x 100 24 x 100 34 x 100 38 x 102 44 x 100
max. RCF 2) 2,379 2,451 2,451 2,594 2,630 2,558 2,558 2,558 2,540 2,540 2,433 2,415 2,612 2,558
radius in mm 133 137 137 145 147 143 143 143 142 142 136 135 146 143
Cat. No. Pediatric microtubes Rhesus tubes 2)
+
Adapter
Spacer
boring Ø x L in mm 11.2 x 38 11.2 x 38 11.2 x 38 6.5 x 34 10.5 x 43 13.4 x 48 13.4 x 48 13.4 x 48 17.6 x 91 17.6 x 91 25.2 x 87 35.2 x 87 38.5 x 92 45.9 x 98
vessels per rotor 20 20 20 108 36 20 20 20 16 16 4 4 4 4
Cat. No. 1351 1351 1351 1339 1343 1383 1383 1383 1329 1329 1330 1331 1396 0761
2) Please note that the RCF values indicated refer only to rotor performance. The max. permissible RCF of tubes used should be verified with the individual manufacturers.
The max. RCF for glass tubes annotated with footnote 2) is 4,000.
5) Tested by TÜV in conformity with DIN EN 61010, section 2 - 020.
55
ROTOFIX 32 A | BENCHTOP CENTRIFUGES
Rotor
max. RPM | max. RCF
max. capacity
4,000 min-1 | 2,665
4 x 100 ml
+ Bucket
Lid bioseal 5)
Cat. No.
1492
1481
run-up | run-down, braked in sec 22 | 25
angle | max. noise level 90° | 55 dB (A)
Cat. No. 1624
Vessels
capacity in ml 1.1–1.4 2.7–5 2.6–4.9 4–8.5 9–10 10 1.6 – 7 4 – 10 5 15 50 12 25 30 50
Ø x L in mm 8 x 66 11 x 66/92 13 x 65/90 15 x 75/92 16 x 92 15 x 102 13 x 75/100 16 x 75/100 17 x 59 17 x 120 29 x 115 17 x 100 25 x 90 25 x 110 29 x 115
max. RCF 2) 2,576 2,558 2,558 2,576 2,540 2,665 2,558 2,522 2,665 2,665 2,665 2,665 2,343 2,665 2,665
radius in mm 144 143 143 144 142 149 143 141 149 149 149 149 131 149 149
Cat. No. blood collection / urine vessels - tubes with screw cap
+
Adapter
boring Ø x L in mm 9 x 49 13.4 x 48 13.4 x 48 15.6 x 47 17.6 x 91 17.6 x 91 13.4 x 48 16.5 x 56 17 x 45 17 x 90 30 x 90 17 x 80 26 x 72 26 x 80 29.5 x 80
vessels per rotor 28 20 20 16 16 16 20 16 12 4 4 4 4 4 4
Cat. No. 1457 1383 1383 1459 1329 1329 4) 1383 1348 6341 1347 1384 6311 1363 1365 6318
chrome
bath tubes
Vessels
capacity in ml 10 30 50 85 30
Ø x L in mm 16 x 80 26 x 95 29 x 107 38 x 106 44 x 105
max. RCF 2) 2,522 2,451 2,630 2,612 2,540
radius in mm 141 137 147 146 142
Cat. No. tubes with screw cap 0534 6)
+
Adapter
Spacer
2) Please note that the RCF values indicated refer only to rotor performance. The max. permissible RCF of tubes used should be verified with the individual manufacturers.
The max. RCF for glass tubes annotated with footnote 2) is 4,000.
3) When using these tubes, bucket 1490 cannot be closed with lid 1492.
4) Please remove spacer.
5) Tested by TÜV in conformity with DIN EN 61010, section 2 - 020.
6) A rubber stopper for closing the tube for agitating or mixing is available under Cat. No. 0535. The tube may not be centrifuged with the stopper.
56
SWING-OUT ROTOR, 4-PLACE | 1324
+
Rotor Bucket
max. RPM | max. RCF 4,000 min-1 | 2,630 Lid bioseal 5) 1492
ROTOFIX 32 A
max. capacity 4 x 100 ml Cat. No. 1490
run-up | run-down, braked in sec 27 | 30
angle | max. noise level 90° | 55 dB (A)
Cat. No. 1324
Vessels
capacity in ml 0.5 1.5 2.0 1 3 4 5 6 7 9 15 25 50 94 100
Ø x L in mm 10.7 x 36 11 x 38 11 x 38 6 x 45 10 x 60 10 x 88 12 x 75 12 x 82 12 x 100 14 x 100 17 x 100 24 x 100 34 x 100 38 x 102 44 x 100
max. RCF 2) 2,343 2,415 2,415 2,558 2,594 2,594 2,522 2,522 2,522 2,504 2,504 2,397 2,379 2,576 2,522
radius in mm 131 135 135 143 145 145 141 141 141 140 140 134 133 144 141
Cat. No. Pediatric microliter tubes Rhesus tubes 2)
+
Adapter
Spacer
boring Ø x L in mm 11.2 x 38 11.2 x 38 11.2 x 38 6.5 x 34 10.5 x 43 10.5 x 43 13.4 x 48 13.4 x 48 13.4 x 48 17.6 x 91 17.6 x 91 25.2 x 87 35.2 x 87 38.5 x 92 45.9 x 100.5
vessels per rotor 20 20 20 108 36 36 20 20 20 16 16 4 4 4 4
Cat. No. 1351 1351 1351 1339 1343 1343 1383 1383 1383 1329 1329 1330 1331 1396 0761
Vessels
capacity in ml 1.1–1.4 2.6–3.4 4.9 2.7–3 4.5–5 4–5.5 7.5 – 8.5 9 – 10 10 1.6 – 5 4–7 4–7 8.5 – 10 5 15
Ø x L in mm 8 x 66 13 x 65 13 x 90 11 x 66 11 x 92 15 x 75 15 x 92 16 x 92 15 x 102 13 x 75 13 x 100 16 x 75 16 x 100 17 x 59 17 x 120
max. RCF 2) 2,540 2,522 2,522 2,522 2,522 2,540 2,540 2,504 2,630 2,522 2,522 2,486 2,486 2,630 2,630
radius in mm 142 141 141 141 141 142 142 140 147 141 141 139 139 147 147
Cat. No. blood collection / urine vessels - -
+
Adapter
boring Ø x L in mm 9 x 47 13.4 x 48 13.4 x 48 13.4 x 48 13.4 x 48 15.6 x 47 15.6 x 47 17.6 x 91 17.6 x 91 13.4 x 48 13.4 x 48 16.5 x 56 16.5 x 56 17 x 45 17 x 90
vessels per rotor 28 20 20 20 20 16 16 16 16 20 20 16 16 12 4
Cat. No. 1457 1383 1383 1383 1383 1459 1459 1329 1329 4) 1383 1383 1348 1348 6341 1347
3) chrome
bath tube
Vessels
capacity in ml 15 30 50 12 25 30 50 10 30 50 85 30
Ø x L in mm 17 x 120 25 x 110 29 x 115 17 x 100 25 x 90 25 x 110 29 x 115 16 x 80 26 x 95 29 x 107 38 x 106 44 x 105
max. RCF 2) 2,630 2,630 2,630 2,630 2,308 2,630 2,630 2,486 2,415 2,594 2,576 2,504
radius in mm 147 147 147 147 129 147 147 139 135 145 144 140
Cat. No. tubes with screw cap 0534 6)
+
Adapter
Spacer
boring Ø x L in mm 17 x 107 26 x 80 30 x 90 17 x 80 26 x 72 26 x 80 29.5 x 80 16.5 x 56 26 x 83 29 x 93 38.5 x 92 45.9 x 100.5
vessels per rotor 12 4 4 4 4 4 4 16 4 4 4 4
Cat. No. 1356 1365 1384 6311 1363 1365 6318 1348 4417 4416 1396 0765
57
ROTOFIX 32 A | BENCHTOP CENTRIFUGES
Rotor
max. RPM | max. RCF
max. capacity
4,000 min-1 | 2,612
4 x 50 ml
+ Bucket
Cat. No. 1398
Vessels
capacity in ml 5 6 7 9 15 2.6–3.4 2.7–3 4–5.5 4.5–5 4.9 9 – 10 10 1.6 – 5 4–7 4–7
Ø x L in mm 12 x 75 12 x 82 12 x 100 14 x 100 17 x 100 13 x 65 11 x 66 15 x 75 11 x 92 13 x 90 16 x 92 15 x 102 13 x 75 13 x 100 16 x 75
max. RCF 2) 2,486 2,486 2,486 2,522 2,522 2,486 2,486 2,272 2,486 2,486 2,522 2,522 2,486 2,486 2,397
radius in mm 139 139 139 141 141 139 139 127 139 139 141 141 139 139 134
Cat. No. tubes 2) blood collection / urine vessels
+
+ 0716 + 0716
Adapter
boring Ø x L in mm 13.4 x 57.5 13.4 x 57.5 13.4 x 57.5 17.5 x 81 17.5 x 81 13.4 x 57.5 13.4 x 57.5 17.5 x 81 13.4 x 57.5 13.4 x 57.5 17.5 x 81 17.5 x 81 13.4 x 57.5 13.4 x 57.5 17.5 x 81
vessels per rotor 20 20 20 16 16 20 20 16 20 20 16 16 20 20 16
Cat. No. 1486 1486 1486 1482A 1482A 1486 1486 1482A 1486 1486 1482A 1482A 1486 1486 1482A
Vessels
capacity in ml 8.5 – 10 12 15 50 12 50
Ø x L in mm 16 x 100 17 x 102 17 x 120 29 x 115 17 x 100 29 x 115
max. RCF 2) 2,397 2,451 2,612 2,576 2,522 2,576
radius in mm 134 137 146 144 141 144
Cat. No. blood collection / tubes with screw cap
+
urine vessels
+ 0716
Adapter
boring Ø x L in mm 17.5 x 81 17.5 x 74 17 x 100 30 x 98 17.5 x 81 30 x 98
vessels per rotor 16 12 16 4 16 4
Cat. No. 1482A 1487 1483A 1484 1482A 1484 4)
2) Please note that the RCF values indicated refer only to rotor performance. The max. permissible RCF of tubes used should be verified with the individual manufacturers.
The max. RCF for glass tubes annotated with footnote 2) is 4,000.
4) Please remove spacer.
58
SWING-OUT ROTOR, 6-PLACE | 1619
Rotor
max. RPM | max. RCF 4,000 min-1 | 2,701
ROTOFIX 32 A
max. capacity 6 x 50 ml
run-up | run-down, braked in sec 22 | 25
angle | max. noise level 90° | 54 dB (A)
Cat. No. 1619
Vessels
capacity in ml 15 50
Ø x L in mm 17 x 120 29 x 115
max. RCF 2) 2,701 2,701
radius in mm 151 151
Cat. No. tubes with
+
screw cap
Adapter
boring Ø x L in mm 17 x 84 30 x 87.5
vessels per rotor 6 6
Cat. No. 1462-A -
Rotor
max. RPM | max. RCF 4,000 min-1 | 2,469
max. capacity 8 x 50 ml
run-up | run-down, braked in sec 22 | 25
angle | max. noise level 45° | 53 dB (A)
Cat. No. 1617
Vessels
capacity in ml 15 50
Ø x L in mm 17 x 120 29 x 115
max. RCF 2) 2,469 2,469
radius in mm 138 138
Cat. No. tubes with
+
screw cap
59
ROTOFIX 32 A | BENCHTOP CENTRIFUGES
Rotor
max. RPM | max. RCF 4,000 min-1 | 2,415
max. capacity 8 x 15 ml
run-up | run-down, braked in sec 22 | 25
angle | max. noise level 90° | 53 dB (A)
Cat. No. 1611
Vessels
capacity in ml 5 6 7 10 15 2.6–3.4 2.7–3 4–5.5 4.5–5 7.5 – 8.5 1.6 – 5 4–7 4–7 8.5 – 10
Ø x L in mm 12 x 75 12 x 82 12 x 100 13 x 100 17 x 100 13 x 65 11 x 66 15 x 75 11 x 92 15 x 92 13 x 75 13 x 100 16 x 75 16 x 100
max. RCF 2) 1,914 1,914 2,415 2,415 2,415 1,914 1,914 1,914 2,415 2,415 1,914 2,415 1,914 2,415
radius in mm 107 107 135 135 135 107 107 107 135 135 107 135 107 135
Cat. No. tubes 2) blood collection / urine vessels
+
Bucket
boring Ø x L in mm 13 x 53 13 x 53 13.2 x 81 13.2 x 81 17.5 x 81 13 x 53 13 x 53 17.5 x 53 13.2 x 81 17.5 x 81 13 x 53 13.2 x 81 17.5 x 53 17.5 x 81
vessels per rotor 8 8 8 8 8 8 8 8 8 8 8 8 8 8
Cat. No. 1131-A 1131-A 1643 1643 1644 1131-A 1131-A 1132-A 1643 1644 1131-A 1643 1132-A 1644
Rotor
max. RPM | max. RCF 4,000 min-1 | 2,683
max. capacity 12 x 15 ml
run-up | run-down, braked in sec 22 | 25
angle | max. noise level 55° / 60° / 80° | 52 dB (A)
Cat. No. 1628
Vessels
capacity in ml 5 15 2.6–3.4 2.7–3 4–5.5 7.5 – 8.5 1.6 – 5 4–7 8.5 – 10
Ø x L in mm 12 x 75 17 x 100 13 x 65 11 x 66 15 x 75 15 x 92 13 x 75 16 x 75 16 x 100
max. RCF 2) 2,236 2,683 2,236 2,236 2,254 2,683 2,236 2,254 2,683
radius in mm 125 150 125 125 126 150 125 126 150
Cat. No. tubes 2) blood collection / urine vessels
+
Bucket 2) Please note that the RCF values indicated
refer only to rotor performance. The max.
boring Ø x L in mm 13.2 x 53 17.5 x 79 13.2 x 53 13.2 x 53 17.5 x 53 17.5 x 79 13.2 x 53 17.5 x 53 17.5 x 79 permissible RCF of tubes used should be
vessels per rotor 12 12 12 12 12 12 12 12 12 verified with the individual manufacturers.
The max. RCF for glass tubes annotated with
Cat. No. 1127-A 1621 1127-A 1127-A 1122 1621 1127-A 1122 1621 footnote 2) is 4,000.
60
ANGLE ROTOR, 8-PLACE | 1418
Rotor
max. RPM | max. RCF 4,000 min-1 | 2,612
ROTOFIX 32 A
max. capacity 8 x 50 ml
run-up | run-down, braked in sec 36 | 43
angle | max. noise level 45° | 53 dB (A)
Cat. No. 1418
Vessels
capacity in ml 5 15 1.1–1.4 2.6–3.4 2.7–3 9 – 10 1.6 – 5 4–7 8.5 – 10 12 15 50 12 50 50
Ø x L in mm 12 x 75 17 x 100 8 x 66 13 x 65 11 x 66 16 x 92 13 x 75 13 x 100 16 x 100 17 x 102 17 x 120 29 x 115 17 x 100 29 x 115 29 x 107
max. RCF 2) 2,182 2,540 2,182 2,182 2,182 2,540 2,182 2,612 2,540 2,540 2,594 2,486 2,540 2,486 2,486
radius in mm 122 142 122 122 122 142 122 146 142 142 145 139 142 139 139
Cat. No. tubes 2) blood collection / urine vessels tubes with screw cap
+
+ 1054-A + 0716 + 1054-A + 1054-A + 1054-A + 0716 + 1054-A + 0716 + 0716 + E2109 + E2110-A + 0716
Carrier
boring Ø x L in mm 17.4 x 91 17.4 x 91 17.4 x 91 17.4 x 91 17.4 x 91 17.4 x 91 17.4 x 91 17.4 x 91 17.4 x 91 17.4 x 91 17.4 x 91 30.2 x 92 17.4 x 91 30.2 x 92 30.2 x 92
vessels per rotor 32 32 32 32 32 32 32 32 32 32 32 8 32 8 8
Cat. No. 1467 1467 1467 1467 1467 1467 1467 1467 1467 1467 1467 1468 1467 1468 1468
2) Please note that the RCF values indicated refer only to rotor performance. The max. permissible RCF of tubes used should be verified with the individual manufacturers.
The max. RCF for glass tubes annotated with footnote 2) is 4,000.
61
ROTOFIX 32 A | BENCHTOP CENTRIFUGES
Rotor
max. RPM | max. RCF 6,000 min-1 | 4,226
max. capacity 6 x 94 ml
run-up | run-down, braked in sec 19 | 22
angle | max. noise level 35° | 53 dB (A)
Cat. No. 1620A
Vessels
capacity in ml 0.5 1.5 2.0 3 15 50 94 7.5 – 8.5 9 – 10 10 8.5 – 10 5 15 50 50
Ø x L in mm 10.7 x 36 11 x 38 11 x 38 10 x 60 17 x 100 34 x 100 38 x 102 15 x 92 16 x 92 15 x 102 16 x 100 17 x 59 17 x 120 29 x 115 29 x 115
max. RCF 2) 4,105 4,105 4,105 4,105 3,904 4,146 4,226 3,904 3,904 3,904 3,904 3,824 3,985 3,985 3,985
radius in mm 102 102 102 102 97 103 105 97 97 97 97 95 99 99 99
Cat. No. Pediatric microliter tubes tubes 2) blood collection / urine vessels - tubes with screw cap
+
Adapter
boring Ø x L in mm 11.4x 39 11.4x 39 11.4x 39 11.4x 39 17.5 x 92 35 x 89 38.6 x 90.2 17.5 x 92 17.5 x 92 17.5 x 92 17.5 x 92 17 x 51 17 x 106 29.8 x 97 -
vessels per rotor 24 24 24 24 6 6 6 6 6 6 6 6 6 6 6
Cat. No. 1449 1449 1449 1449 1451 1463 - 1451 1451 1451 1451 1476 1466 1454 1646 8)
Vessels
capacity in ml 10 30 50 85
Ø x L in mm 16 x 80 26 x 85 29 x 107 38 x 106
max. RCF 2) 3,904 3,824 4,025 4,226
radius in mm 97 95 100 105
Cat. No. tubes with screw cap
+
Adapter
boring Ø x L in mm 16.5 x 74 26 x 85 29 x 92 38.6 x 90.2
vessels per rotor 12 6 6 6
Cat. No. 1448 1447 1446 -
2) Please
note that the RCF values indicated refer only to rotor performance. The max. permissible RCF of tubes used should be verified with the individual manufacturers.
The max. RCF for glass tubes annotated with footnote 2) is 4,000.
8) Adapter (Set), 6-place: for conical 50 ml tubes with screw cap.
62
ANGLE ROTOR, 12-PLACE | 1613
Rotor
max. RPM | max. RCF 6,000 min-1 | 4,146
ROTOFIX 32 A
max. capacity 12 x 15 ml
run-up | run-down, braked in sec 13 | 15
angle | max. noise level 35° | 55 dB (A)
Cat. No. 1613
Vessels
capacity in ml 0.5 4 5 6 15 1.1–1.4 2.6–3.4 2.7–3 4.5–5 4.9 7.5 – 8.5 9 – 10 10
Ø x L in mm 10.7 x 36 10 x 88 12 x 75 12 x 82 17 x 100 8 x 66 13 x 65 11 x 66 11 x 92 13 x 90 15 x 92 16 x 92 15 x 102
max. RCF 2) 2,777 3,502 3,300 3,300 4,146 3,300 3,300 3,300 4,146 4,146 4,146 4,146 4,146
radius in mm 69 87 82 82 103 82 82 82 103 103 103 103 103
Cat. No. Pediatric tubes 2) blood collection / urine vessels
+
Adapter
boring Ø x L in mm 11x 35 11.5 x 67.5 13.5 x 60 13.5 x 60 17.7 x 88 13.5 x 60 13.5 x 60 13.5 x 60 17.7 x 88 17.7 x 88 17.7 x 88 17.7 x 88 17.7 x 88
vessels per rotor 12 12 12 12 12 12 12 12 12 12 12 12 12
2 x 1063-6
Cat. No. (6 pcs.) 6305 1054-A 1054-A - 1054-A 1054-A 1054-A - - - - -
Vessels
capacity in ml 1.6 – 5 4–7 8 8.5 – 10 5 15
Ø x L in mm 13 x 75 13 x 100 16 x 125 16 x 100 17 x 59 17 x 120
max. RCF 2) 3,300 4,146 4,146 4,146 3,180 4,146
radius in mm 82 103 103 103 79 103
Cat. No. blood collection / urine vessels - -
+
Adapter
boring Ø x L in mm 13.5 x 60 13.5 x 79 17.7 x 88 17.7 x 88 17 x 25 17.7 x 88 2) Please note that the RCF values indicated refer only to rotor performance.
The max. permissible RCF of tubes used should be verified with the indivi-
vessels per rotor 12 12 6 12 12 6
dual manufacturers.
Cat. No. 1054-A 1058 - - 1064 - The max. RCF for glass tubes annotated with footnote 2) is 4,000.
PACKAGES
ROTOFIX 32 A BLOOD TUBE PACKAGE 1* number of vessels volume (ml) size (mm) RPM RCF
- 1 x ROTOFIX 32 A centrifuge 1206 20 1.6 - 7 13 x 75 / 100 4,000 2,558
- 1 x swing-out rotor, 4-place 1624 16 4 - 10 16 x 75 / 100 4,000 2,522
- 4 x bucket 1481
- 4 x lid (bioseal) 1492
- 4 x adapter, 5-place 1383
- 4 x adapter, 4-place 1348
1206SET1
63
UNIVERSAL 320 | 320 R
A universal choice
The UNIVERSAL 320 is a compact, versatile and indispensable general purpose centrifuge. Excellent performance and a
comprehensive range of accessories enable the UNIVERSAL 320 to carry out virtually any centrifuging tasks including plates,
blood tubes, cell culture, microliter and cytology. This unit is available with refrigeration and a temperature range from -20 °C
to +40 °C (UNIVERSAL 320 R).
64
TECHNICAL DATA
UNIVERSAL 320 UNIVERSAL 320 R
non-refrigerated refrigerated
voltage *) 200 – 240 V 1 ~ 200 – 240 V 1 ~ 240 V 1 ~
frequency 50 – 60 Hz 50 – 60 Hz 60 Hz
consumption 400 VA 800 VA
UNIVERSAL
320 | 320 R
emission, immunity EN / IEC 61326-1, class B EN / IEC 61326-1, class B
max. capacity 4 x 200 ml / 6 x 94 ml 4 x 200 ml / 6 x 94 ml
max. RPM 16,000 min-1 16,000 min-1
max. RCF 24,900 24,900
running time 1sec – 99 min: 59 sec, continuous run, 1sec – 99 min: 59 sec, continuous run,
short cycle mode (impulse button) short cycle mode (impulse button)
dimensions (W x D x H) 401 x 529 x 346 mm 407 x 698 x 346 mm
weight approx. 31 kg approx. 52 kg
noise level 48 dB (A) with rotor 1611 50 dB (A) with rotor 1611
temperature control, infinitely variable - from -20 to +40 °C
Cat. No. 1401 1406
AVAILABLE ROTORS
SWING-OUT ROTORS angle max. RPM max. capacity Cat. No. page
swing-out rotor, 4-places 90° 4,500 min-1 4 x 200 ml 1554 66
swing-out rotor, 4-places 90° 5,000 min-1 4 x 100 ml 1494 69
swing-out rotor, 4-places 90° 4,000 min-1 4 x 100 ml 1624 72
swing-out rotor, 4-places 90° 4,500 min-1 4 x 100 ml 1324 75
swing-out rotor, 8-places 90° 4,000 min-1 8 x 15 ml 1611 77
swing-out rotor, 12-places 55° / 60° / 80° 4,000 min-1 12 x 15 ml 1628 77
swing-out rotor, 8-places 45° 5,000 min-1 8 x 50 ml 1617 78
swing-out rotor, 6-places 90° 4,000 min-1 6 x 50 ml 1619 78
swing-out rotor, 2-places 90° 4,000 min-1 10 plates 1460 79
swing-out rotor, 24-places 90° 13,000 min-1 24 x 2 ml 1555 79
ANGLE ROTORS
angle rotor, 24-places 50° 16,000 min-1 24 x 2 ml 1552 80
angle rotor, 30-places 45° 14,150 min-1 30 x 2 ml 1553 80
angle rotor, 64-places 45° 13,000 min-1 64 x 0.2 ml 1551 81
angle rotor, 18-places 45° 14,150 min-1 18 x 5 ml 1627 81
angle rotor, 6-places 35° 9,000 min-1 6 x 94 ml 1556 82
angle rotor, 12-places 35° 6,000 min-1 12 x 15 ml 1613 83
angle rotor, 12-places 35° 12,000 min-1 12 x 15 ml 1615 84
angle rotor, 8-places 45° 4,500 min-1 8 x 50 ml 1418 85
65
UNIVERSAL 320 | 320 R | BENCHTOP CENTRIFUGES
Bucket
Rotor with clamp lock
+
max. RPM | max. RCF 4,500 min-1 | 3,328 Lid bioseal 5) 1561
max. capacity 4 x 200 ml Cat. No. 1560
run-up | run-down, braked in sec 28 | 31
Bucket
angle | max. noise level 90° | 60 dB (A) without clamp lock 14)
temperature in °C 1) -8 Cat. No. 1565
Cat. No. 1554
3.2)
Vessels
capacity in ml 1.5 2.0 5 5 6 7 9 15 15 25 50 94 100 125 150
Ø x L in mm 11 x 38 11 x 38 17 x 59 12 x 75 12 x 82 12 x 100 14 x 100 17 x 100 18 x 102 24 x 100 34 x 100 38 x 102 44 x 100 51 x 100 51 x 116
max. RCF 2) 3,328 2,332 3,328 3,215 3,215 3,215 3,215 3,215 3,260 3,056 3,147 3,260 3,147 3,328 3,328
radius in mm 147 103 147 142 142 142 142 142 144 135 139 144 139 147 147
Cat. No. microliter tubes tubes 2) - -
+
Adapter
boring Ø x L in mm 11.5 x 39 11.5 x 39 17 x 52 13.5 x 60 13.5 x 60 13.5 x 60 17.5 x 60 17.5 x 60 18.5 x 74 25.2 x 66 35.2 x 69 38.5 x 74 45.5 x 69 52 x 77 52 x 77
vessels per rotor 56 56 16 28 28 28 20 20 16 4 4 4 4 4 4
Cat. No. 1571 1571 1593 1589 1589 1589 1588 1588 1572 1573 1574 1575 1576 1594 1594
Vessels
capacity in ml 200 1.1–1.4 2.6 – 3.4 4.9 2.7 – 3 4.5 – 5 4 – 5.5 7.5 – 8.5 9 – 10 10 1.6 – 5 4–7 4–7 8.5 – 10 12
Ø x L in mm 56 x 112 8 x 66 13 x 65 13 x 90 11 x 66 11 x 92 15 x 75 15 x 92 16 x 92 15 x 102 13 x 75 13 x 100 16 x 75 16 x 100 17 x 102
max. RCF 2) 3,328 3,215 3,215 3,215 3,215 3,215 3,215 3,215 3,215 3,215 3,215 3,215 3,215 3,215 3,215
radius in mm 147 142 142 142 142 142 142 142 142 142 142 142 142 142 142
Cat. No. 0555 blood collection / urine vessels
+
Adapter
boring Ø x L in mm 57 x 77 13.5 x 60 13.5 x 60 13.5 x 60 13.5 x 60 13.5 x 60 17.5 x 60 17.5 x 60 17.5 x 60 17.5 x 60 13.5 x 60 13.5 x 60 17.5 x 60 17.5 x 60 17 x 74
vessels per rotor 4 28 28 28 28 28 20 20 20 20 28 28 20 20 12
Cat. No. - 1589 1589 1589 1589 1589 1588 1588 1588 1588 1589 1589 1588 1588 1591
3.2) chrome
bath tube
Vessels
capacity in ml 11 15 15 30 50 12 25 30 50 10 30 50 85 94 30
Ø x L in mm 16 x 110 17 x 120 17 x 120 25 x 110 29 x 115 17 x 100 25 x 90 15 x 110 29 x 115 16 x 80 26 x 95 29 x 107 38 x 106 38 x 102 44 x 105
max. RCF 2) 3,260 3,328 3,328 3,328 3,328 3,260 3,328 3,328 3,328 3,215 3,260 3,260 3,260 3,260 3,192
radius in mm 144 147 147 147 147 144 147 147 147 142 144 144 144 144 141
Cat. No. Nunc® tubes with screw cap 0534 6)
+
Adapter
+ E 2109
boring Ø x L in mm 17.5 x 74 17 x 77 17 x 77 26 x 77 30 x 77 17.5 x 74 26 x 65 26 x 65 30 x 77 16.5 x 60 26 x 74 29 x 74 38.5 x 74 38.5 x 74 45 x 71
vessels per rotor 16 8 12 4 4 16 4 4 4 20 4 4 4 4 4
Cat. No. 1581 1577 1595 1578 1579 1581 1582 1582 1583 1584 1585 1586 1575 1575 1587
66
SWING-OUT ROTOR, 4-PLACE | 1554
+
Rotor Bucket
max. RPM | max. RCF 4,500 min-1 | 3,328 Cat. No. 1559
UNIVERSAL
320 | 320 R
max. capacity 4 x 50 ml
run-up | run-down, braked in sec 28 | 31
angle | max. noise level 90° | 58 dB (A)
temperature in °C 1) -8
Cat. No. 1554
Vessels
capacity in ml 5 6 7 8 9 15 2.6 – 3.4 2.7 – 3 4 – 5.5 4.5 – 5 4.9 9 – 10 10 1.6 – 5 4–7
Ø x L in mm 12 x 75 12 x 82 12 x 100 16 x 125 14 x 100 17 x 100 13 x 65 11 x 66 15 x 75 11 x 92 13 x 90 16 x 92 10 x 102 13 x 75 13 x 100
max. RCF 2) 3,192 3,192 3,192 3,328 3,260 3,260 3,192 3,192 3,124 3,192 3,192 3,260 3,260 3,192 3,192
radius in mm 141 141 141 147 144 144 141 141 138 141 141 144 144 141 141
Cat. No. tubes 2) blood collection / urine vessels
+
Adapter
+ 0715
boring Ø x L in mm 13.4 x 57.5 13.4 x 57.5 13.4 x 57.5 16.4 x 82 17.5 x 81 17.5 x 81 13.4 x 57.5 13.4 x 57.5 17.5 x 81 13.4 x 57.5 13.4 x 57.5 17.5 x 81 17.5 x 81 13.4 x 57.5 13.4 x 57.5
vessels per rotor 20 20 20 16 16 16 20 20 16 20 20 16 16 20 20
Cat. No. 1486 1486 1486 1488 1482A 1482A 1486 1486 1482A 1486 1486 1482A 1482A 1486 1486
Vessels
capacity in ml 4–7 8.5 – 10 8 12 15 50 12 50
Ø x L in mm 16 x 75 16 x 100 16 x 125 17 x 102 17 x 120 29 x 115 17 x 100 29 x 115
max. RCF 2) 3,124 3,260 3,328 3,147 3,351 3,305 3,260 3,305
radius in mm 138 144 147 139 148 146 144 146
Cat. No. blood- / urine vessels tubes with screw cap
+
Adapter
+ 0715 + 0715
1) For cooled versions: Lowest temperature achievable with precooling and max. speed.
2) Please note that the RCF values indicated refer only to rotor performance. The max. permissible RCF of tubes used should be verified with the individual manufacturers.
The max. RCF for glass tubes annotated with footnote 2) is 4,000.
3.2) When using these tubes, bucket 1560 cannot be closed with lid 1561.
4) Please remove the spacer.
5) Tested by the TÜV in conformity with DIN EN 61010, section 2 - 020.
6) A rubber stopper for closing the tube for agitating or mixing is available under Cat. No. 0535. The tube may not be centrifuged with the stopper.
14) With the E3922 add-on kit and the 1561 lid, the 1565 carrier can be converted at a later time to a 1560 carrier with single-hand clamp lock.
67
UNIVERSAL 320 | 320 R | BENCHTOP CENTRIFUGES
Rotor Bucket
max. RPM | max. RCF
max. capacity
run-up | run-down, braked in sec
4,500 min-1 | 3,260
8 x 50 ml
28 | 31
+ Cat. No. 1563
Vessels
capacity in ml 12 15 50 50
Ø x L in mm 17 x 100 17 x 120 29 x 115 29 x 115
max. RCF 2) 3,260 3,260 3,260 3,260
radius in mm 144 144 144 144
Cat. No. tubes with screw cap
+
Adapter
+ E 2109 + E 2110-A
1) For cooled versions: Lowest temperature achievable with precooling and max. speed.
2) Please note that the RCF values indicated refer only to rotor performance. The max. permissible RCF of tubes used should be verified with the individual manufacturers.
The max. RCF for glass tubes annotated with footnote 2) is 4,000.
68
SWING-OUT ROTOR, 4-PLACE | 1494
Rotor Bucket
max. RPM | max. RCF 5,000 min-1 | 4,193
+ Cat. No. 1425
UNIVERSAL
320 | 320 R
max. capacity 4 x 100 ml
run-up | run-down, braked in sec 30 | 32
angle | max. noise level 90° | 56 dB (A)
temperature in °C 1) -10
Cat. No. 1494
Vessels
capacity in ml 1.5 2.0 1 3 5 6 7 9 15 25 50 100 1 – 8
Ø x L in mm 11 x 38 11 x 38 6 x 45 10 x 60 12 x 75 12 x 82 12 x 100 14 x 100 17 x 100 24 x 100 34 x 100 44 x 100 simple / multiple
max. RCF 2) 3,885 3,885 3,969 3,913 3,913 3,913 3,913 3,913 3,913 3,913 3,913 3,801 2,739
radius in mm 139 139 142 140 140 140 140 140 140 140 140 136 98
Cat. No. microliter tubes Rhesus tubes 2) cyto chambers
+
Adapter
boring Ø x L in mm 11.5 x 38 11.5 x 38 6.5 x 34 10.5 x 40 13.4 x 50 12.7 x 60 12.7 x 60 17.5 x 84 17.5 x 84 25.5 x 84 35.5 x 84 45.5 x 86 -
vessels per rotor 36 36 144 56 28 48 48 28 28 8 4 4 4
Cat. No. 1444 1444 1432 1433 1438 1434 1434 1431 1431 1435 1436 1437 1452
Vessels
capacity in ml 2.6 – 3.4 2.7 – 3 4 – 5.5 4.5 – 5 4.9 7.5 – 8.5 9 – 10 1.6 – 5 4–7 4–7 8.5 – 10 15 50 50
Ø x L in mm 13 x 65 11 x 66 15 x 75 11 x 92 13 x 90 15 x 92 16 x 92 13 x 75 13 x 100 16 x 75 16 x 100 17 x 120 29 x 115 19 x 115
max. RCF 2) 3,913 3,913 3,913 3,913 3,913 3,913 3,913 3,913 3,913 3,913 3,913 4,081 4,081 4,081
radius in mm 140 140 140 140 140 140 140 140 140 140 140 146 146 146
Cat. No. blood collection / urine vessels tubes with screw cap
+
Adapter
boring Ø x L in mm 13.4 x 50 13.4 x 50 16.5 x 50 13.4 x 50 13.4 x 50 16.5 x 50 17 x 45 13.4 x 50 13.4 x 50 16.5 x 50 16.5 x 50 17 x 90 30 x 90 30 x 90
vessels per rotor 28 28 28 28 28 28 16 28 28 28 28 4 4 4
Cat. No. 1438 1438 1441 1438 1438 1441 1439 1438 1438 1441 1441 1442 1443 1737
1) For cooled versions: Lowest temperature achievable with precooling and max. speed.
2) Please note that the RCF values indicated refer only to rotor performance. The max. permissible RCF of tubes used should be verified with the individual manufacturers.
The max. RCF for glass tubes annotated with footnote 2) is 4,000.
69
UNIVERSAL 320 | 320 R | BENCHTOP CENTRIFUGES
Rotor Bucket
max. RPM | max. RCF
max. capacity
run-up | run-down, braked in sec
5,000 min-1 | 4,109
4 x 50 ml
30 | 32
+ Lid
Cat. No.
1421
1427
Vessels
capacity in ml 1.5 2.0 1 3 5 6 7 9 15 25 50 1.1–1.4 2.6 – 3.4 2.7 – 3 4 – 5.5
Ø x L in mm 11 x 38 11 x 38 6 x 45 10 x 60 12 x 75 12 x 82 12 x 100 14 x 100 17 x 100 24 x 100 34 x 100 8 x 66 13 x 65 11 x 66 15 x 75
max. RCF 2) 4,109 4,109 4,081 4,053 4,025 4,053 3,941 3,941 3,941 3,941 3,941 4,109 4,025 4,053 4,109
radius in mm 147 147 146 145 144 145 141 141 141 141 141 147 144 145 147
Cat. No. microliter tubes Rhesus tubes 2) blood collection / urine vessels
+
Adapter
boring Ø x L in mm 11.5 x 38 11.5 x 38 6.5 x 34 10.5 x 40 13.4 x 58 12.5 x 44 12.4 x 87 15 x 73 17.8 x 87 25.5 x 87 35.5 x 87 9 x 41 13.4 x 58 12.5 x 44 15.6 x 41
vessels per rotor 36 36 120 48 32 48 48 24 24 8 4 48 32 48 20
Cat. No. 5277 5277 1357 1327 1732 5229 5230 5237 5231 5232 5233 5278 1732 5229 5279
Vessels
capacity in ml 4.5 – 5 4.9 7.5 – 8.5 9 – 10 1.6 – 5 4–7 4–7 8.5 – 10 15 50 25 30 50
Ø x L in mm 11 x 92 13 x 90 15 x 92 16 x 92 13 x 75 13 x 100 16 x 75 16 x 100 17 x 120 29 x 115 25 x 90 25 x 110 29 x 115
max. RCF 2) 3,941 4,025 4,105 3,969 4,025 4,025 3,969 3,941 4,165 4,053 3,565 4,025 4,053
radius in mm 141 144 147 142 144 144 142 141 145 145 142 144 145
Cat. No. blood collection / urine vessels tubes with screw cap
+
+ 6316
Adapter
boring Ø x L in mm 12.4 x 87 13.4 x 58 15.6 x 41 17 x 66 13.4 x 58 13.4 x 58 17 x 66 17.8 x 87 17 x 90 30 x 90 25.5 x 72 25.5 x 85 35.5 x 87
vessels per rotor 48 32 20 20 32 32 20 24 4 4 8 4 4
Cat. No. 5230 1732 5279 5271 4) 1732 1732 5271 4) 5231 5275 5276 1731 5272 5233 4)
1) For cooled versions: Lowest temperature achievable with precooling and max. speed.
2) Please note that the RCF values indicated refer only to rotor performance. The max. permissible RCF of tubes used should be verified with the individual manufacturers.
The max. RCF for glass tubes annotated with footnote 2) is 4,000.
3.1) When using these tubes, carrier 1427 cannot be closed with lid 1421.
4) Please remove the spacer.
70
SWING-OUT ROTOR, 4-PLACE | 1494
Rotor Bucket
max. RPM | max. RCF 5.000 min-1 | 4.193
+ Lid bioseal 5) 1492
UNIVERSAL
320 | 320 R
max. capacity 4 x 100 ml Cat. No. 1495
run-up | run-down, braked in sec 30 | 32
angle | max. noise level 90° | 58 dB (A)
temperature in °C 1) -10
Cat. No. 1494
Vessels
capacity in ml 0.5 1.5 2.0 1 3 5 6 7 9 15 25 50 94 100
Ø x L in mm 10.7 x 36 11 x 38 11 x 38 6 x 45 10 x 60 12 x 75 12 x 82 12 x 100 14 x 100 17 x 100 24 x 100 34 x 100 38 x 102 44 x 100
max. RCF 2) 3,745 3,857 3,857 4,081 4,137 4,025 4,025 4,025 3,997 3,997 3,829 3,801 4,109 4,025
radius in mm 134 138 138 146 148 144 144 144 143 143 137 136 147 144
Cat. No. Pediatric microliter tubes Rhesus tubes 2)
+
Adapter
Spacer
boring Ø x L in mm 11.2 x 38 11.2 x 38 11.2 x 38 6.5 x 34 10.5 x 40 13.4 x 48 13.4 x 48 13.4 x 48 17.6 x 91 17.6 x 91 25.2 x 87 35.2 x 87 38.5 x 92 45.6 x 98
vessels per rotor 20 20 20 108 36 20 20 20 16 16 4 4 4 4
Cat. No. 1351 1351 1351 1339 1343 1383 1383 1383 1329 1329 1330 1331 1396 0761
Vessels
capacity in ml 1.1–1.4 2.7 – 5 2.7 – 5 2.6 – 4.9 2.6 – 4.9 4 – 8.5 4 – 8.5 9 – 10 10 1.6 – 5 1.6 – 5 4 – 10 4 – 10
Ø x L in mm 8 x 66 11 x 66 11 x 92 13 x 65 13 x 90 15 x 75 15 x 92 16 x 92 15 x 102 13 x 75 13 x 100 16 x 75 16 x 100
max. RCF 2) 4,053 4,025 4,025 4,025 4,025 4,053 4,053 3,997 4,193 4,025 4,025 4,025 4,025
radius in mm 145 144 144 144 144 145 145 143 150 144 144 144 144
Cat. No. blood collection / urine vessels
+
Adapter
boring Ø x L in mm 9 x 47 13.4 x 48 13.4 x 48 13.4 x 48 13.4 x 48 15.6 x 47 15.6 x 47 17.6 x 91 17.6 x 91 13.4 x 48 13.4 x 48 16.5 x 56 16.5 x 56
vessels per rotor 28 20 20 20 20 16 16 16 16 20 20 16 16
Cat. No. 1457 1383 1383 1383 1383 1459 1459 1329 1329 4) 1383 1383 1348 1348
3) 3) 3) chrome
bath tube 1) For cooled versions: Lowest
temperature achievable with
precooling and max. speed.
Vessels 2) Please note that the RCF values
indicated refer only to rotor perfor-
capacity in ml 15 30 50 12 25 50 10 30 50 85 30 mance. The max. permissible RCF
Ø x L in mm 17 x 120 25 x 110 29 x 115 17 x 100 25 x 90 29 x 115 16 x 80 26 x 95 29 x 107 38 x 106 44 x 105 of tubes used should be verified
with the individual manufacturers.
max. RCF 2) 4,193 4,193 4,193 4,193 3,689 4,193 4,025 3,857 4,137 4,109 3,997
The max. RCF for glass tubes an-
radius in mm 150 150 150 150 132 150 144 138 148 147 143 notated with footnote 2) is 4,000.
Cat. No. tubes with screw cap 0534 6) 3) When using these tubes, bucket
+
1495 cannot be closed with lid
Spacer 1492.
4) Please remove the spacer.
5) Tested by the TÜV in conformity
with DIN EN 61010. section 2 - 020.
Adapter
6) A rubber stopper for closing the
boring Ø x L in mm 17 x 90 26 x 80 30 x 90 17 x 80 26 x 72 29.5 x 80 16.5 x 56 26 x 83 29 x 93 38.5 x 92 45.9 x 98 tube for agitating or mixing is
vessels per rotor 4 4 4 4 4 4 16 4 4 4 4 available under Cat. No. 0535.
The tube may not be centrifuged
Cat. No. 1347 1365 1384 6311 1363 6318 1348 4417 4416 1396 0765 with the stopper.
71
UNIVERSAL 320 | 320 R | BENCHTOP CENTRIFUGES
Rotor
max. RPM | max. RCF 4,000 min-1 | 2,665
max. capacity 4 x 50 ml
run-up | run-down, braked in sec 20 | 25
angle 90°
Cat. No. 1624
Vessels
capacity in ml 5 5 6 7 9 9 15 15 20 25 45 50 1 – 8
Ø x L in mm 12 x 75 12 x 75 12 x 82 12 x 100 14 x 100 14 x 100 17 x 100 17 x 100 21 x 100 24 x 100 31 x 100 34 x 100 simple / multiple
max. RCF 2) 2,057 2,164 2,308 2,308 2,308 2,415 2,308 2,415 2,361 2,451 2,361 2.451 1,646
radius in mm 115 121 129 129 129 135 129 137 132 137 132 137 92
temperature in °C 1) -17 -17 -17 -17 -17 -15 -17 -15 -15 -15 -15 -15 -16
Cat. No. tubes 2) cyto chambers
+
+ 0701
boring Ø x L in mm 12.5 x 64.4 13.5 x 65 12.5 x 71.5 12.5 x 71.5 14.6 x 74 14.6 x 78 17.6x71.5 17.6 x 78 21.5 x 74 26 x 78 32 x 74 35 x 78 -
vessels per rotor 16 68 16 16 20 40 16 28 8 8 4 4 4
Cat. No. 1369-91 1372 1369-92 1369-92 1370 1741 1369 1742 1346 1745 1345 1746 1660
Vessels
capacity in ml 1.1 – 1.4 2.6 – 3.4 4.5 – 5 4.9 1.6 – 5 4–7 1.6 – 5 4–7 4–7 4–7 4–7 8.5 – 10 30
Ø x L in mm 8 x 66 13 x 65 15 x 75 13 x 90 13 x 75 16 x 75 13 x 75 16 x 75 13 x 100 13 x 100 13 x 100 16 x 100 26 x 95
max. RCF 2) 2,415 2,325 2,325 2,451 2,129 2,361 2,325 2,325 2,361 2,361 2,451 2,361 2,451
radius in mm 135 130 130 137 119 132 130 130 132 132 137 132 137
temperature in °C 1) -15 -15 -15 -15 -15 -15 -15 -15 -15 -15 -15 -17 -15
Cat. No. blood collection / urine vessels 0545
+
+ 0701 + 0716 + 0716 + 0768 16) + 0716 + 0716 + 1058
Carrier
boring Ø x L in mm 14.6 x 78 17.6 x 78 17.6 x 78 14.6 x 78 14.6 x 78 17.6x71.5 17.6 x 78 17.6 x 78 17.6x71.5 14.6 x 74 13.5 x 78 17.6x71.5 26 x 78
vessels per rotor 40 28 28 40 40 16 28 28 16 20 28 16 8
Cat. No. 1741 1742 1742 1741 1741 1369 4) 1742 1742 1369 4) 1370 4) 1739 1369 4) 1745
1) For cooled versions: Lowest temperature achievable with precooling and max. speed.
2) Please note that the RCF values indicated refer only to rotor performance. The max. permissible RCF of tubes used should be verified with the individual manufacturers.
The max. RCF for glass tubes annotated with footnote 2) is 4,000.
4) Please remove spacer.
5) Tested by the TÜV in conformity with DIN EN 61010. section 2 - 020.
16) Packed in units of 10 pieces.
20) This combination permits no Vacutainers made of glass.
72
SWING-OUT ROTOR, 4-PLACE | 1624
Rotor Bucket
max. RPM | max. RCF 4,000 min-1 | 1,968
+ Cat. No. 1366
UNIVERSAL
320 | 320 R
max. capacity 48 x 4 ml
run-up | run-down, braked in sec 22 | 25
angle | max. noise level 90° | 48 dB (A)
temperature in °C -15
Cat. No. 1624
Vessels
capacity in ml 1.5 2.0 1 3 4
Ø x L in mm 11 x 38 11 x 38 6 x 45 10 x 60 12 x 60
max. RCF 2) 1,968 1,968 1,950 1,932 1,932
radius in mm 110 110 109 108 108
Cat. No. microliter tubes Rhesus tubes 2)
+
Adapter
boring Ø x L in mm 11.5 x 38 11.5 x 38 6.5 x 23 10.5 x 23 12.5 x 44
vessels per rotor 36 36 120 48 48
Cat. No. 5277 5277 1357 1327 1326
Rotor Bucket
max. RPM | max. RCF 2)
max. capacity
run-up | run-down, braked in sec
4,000 min-1 | 2,665
4 x 100 ml
20 | 25
+ Lid bioseal 5)
Cat. No.
1492
1481
Vessels
capacity in ml 0.5 1.5 2.0 1 3 5 6 7 9 15 25 50 94 100
Ø x L in mm 10.7 x 36 11 x 38 11 x 38 6 x 45 10 x 60 12 x 75 12 x 82 12 x 100 14 x 100 17 x 100 24 x 100 34 x 100 38 x 102 44 x 100
max. RCF 2) 2,379 2,451 2,451 2,594 2,630 2,558 2,558 2,558 2,540 2,540 2,433 2,415 2,612 2,558
radius in mm 133 137 137 145 147 143 143 143 142 142 136 135 146 143
Cat. No. Pediatric microliter tubes Rhesus tubes 2)
+
Adapter
Spacer
boring Ø x L in mm 11.2 x 38 11.2 x 38 11.2 x 38 6.5 x 34 10.5 x 43 13.4 x 48 13.4 x 48 13.4 x 48 17.6 x 91 17.6 x 91 25.2 x 87 35.2 x 87 38.5 x 92 45.9 x 98
vessels per rotor 20 20 20 108 36 20 20 20 16 16 4 4 4 4
Cat. No. 1351 1351 1351 1339 1343 1383 1383 1383 1329 1329 1330 1331 1396 0761
73
UNIVERSAL 320 | 320 R | BENCHTOP CENTRIFUGES
Rotor Bucket
max. RPM | max. RCF
max. capacity
run-up | run-down, braked in sec
4,000 min-1 | 2,665
4 x 100 ml
20 | 25
+ Lid bioseal 5)
Cat. No.
1492
1481
Vessels
capacity in ml 1.1–1.4 2.7–5 2.7–5 2.6–4.9 2.6–4.9 4–8.5 4–8.5 9–10 10 1.6 – 7 1.6 – 7 4 – 10 4 – 10
Ø x L in mm 8 x 66 11 x 66 11 x 92 13 x 65 13 x 90 15 x 75 15 x 92 16 x 92 15 x 102 13 x 75 13 x 100 16 x 75 16 x 100
max. RCF 2) 2,576 2,558 2,558 2,558 2,558 2,576 2,576 2,540 2,665 2,558 2,558 2,522 2,522
radius in mm 144 143 143 143 143 144 144 142 149 143 143 141 141
Cat. No. blood collection / urine vessels
+
Adapter
boring Ø x L in mm 9 x 47 13.4 x 48 13.4 x 48 13.4 x 48 13.4 x 48 15.6 x 47 15.6 x 47 17.6 x 91 17.6 x 91 13.4 x 48 13.4 x 48 16.5 x 56 16.5 x 56
vessels per rotor 28 20 20 20 20 16 16 16 16 20 20 16 16
Cat. No. 1457 1383 1383 1383 1383 1459 1459 1329 1329 4) 1383 1383 1348 1348
chrome
bath tube
Vessels
capacity in ml 5 15 50 12 25 30 50 10 30 50 85 30
Ø x L in mm 17 x 59 17 x 120 29 x 115 17 x 100 25 x 90 25 x 110 29 x 115 16 x 80 26 x 95 29 x 107 38 x 106 44 x 105
max. RCF 2) 2,665 2,665 2,665 2,665 2,343 2,665 2,665 2,522 2,451 2,630 2,612 2,540
radius in mm 149 149 149 149 131 149 149 141 137 147 146 142
Cat. No. - tubes with screw cap 0534 6)
+
Adapter
Spacer
boring Ø x L in mm 17 x 45 17 x 90 30 x 90 17 x 80 26 x 72 26 x 80 29.5 x 80 16.5 x 56 26 x 83 29 x 93 38.5 x 92 45.9 x 98
vessels per rotor 12 4 4 4 4 4 4 16 4 4 4 4
Cat. No. 6341 1347 1384 6311 1363 1365 6318 1348 4417 4416 1396 0765
1) For cooled versions: Lowest temperature achievable with precooling and max. speed.
2) Please note that the RCF values indicated refer only to rotor performance. The max. permissible RCF of tubes used should be verified with the individual manufacturers.
The max. RCF for glass tubes annotated with footnote 2) is 4,000.
3.3) When using these tubes, bucket 1752 or 5051 cannot be closed with lid 1751 or 5053.
4) Please remove the spacer.
5) Tested by the TÜV in conformity with DIN EN 61010. section 2 - 020.
6) A rubber stopper for closing the tube for agitating or mixing is available under Cat. No. 0535. The tube may not be centrifuged with the stopper.
74
SWING-OUT ROTOR, 4-PLACE | 1324
Rotor Bucket
max. RPM | max. RCF 4,500 min-1 | 3,328
+ Lid bioseal 5) 1492
UNIVERSAL
320 | 320 R
max. capacity 4 x 100 ml Cat. No. 1490
run-up | run-down, braked in sec 27 | 30
angle | max. noise level 90° | 58 dB (A)
temperature in °C -6
Cat. No. 1324
Vessels
capacity in ml 0.5 1.5 2.0 1 3 4 5 6 7 9 15 25 50 94 100
Ø x L in mm 10.7 x 36 11 x 38 11 x 38 6 x 45 10 x 60 10 x 88 12 x 75 12 x 82 12 x 100 14 x 100 17 x 100 24 x 100 34 x 100 38 x 102 44 x 100
max. RCF 2) 2,966 3,056 3,056 3,237 3,283 3,283 3,192 3,192 3,192 3,170 3,170 3,034 3,011 3,260 3,192
radius in mm 131 135 135 143 145 145 141 141 141 140 140 134 133 144 141
Cat. No. Pediatric microliter tubes Rhesus tubes 2)
+
Adapter
Spacer
boring Ø x L in mm 11.2 x 38 11.2 x 38 11.2 x 38 6.5 x 34 10.5 x 43 10.5 x 43 13.4 x 48 13.4 x 48 13.4 x 48 17.6 x 91 17.6 x 91 25.2 x 87 35.2 x 87 38.5 x 92 45.9 x 100.5
vessels per rotor 20 20 20 108 36 36 20 20 20 16 16 4 4 4 4
Cat. No. 1351 1351 1351 1339 1343 1343 1383 1383 1383 1329 1329 1330 1331 1396 0761
Vessels
capacity in ml 1.1–1.4 2.6–3.4 4.9 2.7–3 4.5–5 4–5.5 7.5 – 8.5 9 – 10 10 1.6 – 5 4–7 4–7 8.5 – 10 5 15
Ø x L in mm 8 x 66 13 x 65 13 x 90 11 x 66 11 x 92 15 x 75 15 x 92 16 x 92 15 x 102 13 x 75 13 x 100 16 x 75 16 x 100 17 x 59 17 x 120
max. RCF 2) 3,215 3,192 3,192 3,192 3,192 3,215 3,215 3,170 3,328 3,192 3,192 3,147 3,147 3,328 3,328
radius in mm 142 141 141 141 141 142 142 140 147 141 141 139 139 147 147
Cat. No. blood collection / urine vessels - -
+
Adapter
boring Ø x L in mm 9 x 47 13.4 x 48 13.4 x 48 13.4 x 48 13.4 x 48 15.6 x 47 15.6 x 47 17.6 x 91 17.6 x 91 13.4 x 48 13.4 x 48 16.5 x 56 16.5 x 56 17 x 45 17 x 90
vessels per rotor 28 20 20 20 20 16 16 16 16 20 20 16 16 12 4
Cat. No. 1457 1383 1383 1383 1383 1459 1459 1329 1329 4) 1383 1383 1348 1348 6341 1347
3.3) chrome
bath tube
Vessels
Kapazität in ml 15 30 50 12 25 30 50 10 30 50 85 30
Ø x L in mm 17 x 120 25 x 110 29 x 115 17 x 100 25 x 90 25 x 110 29 x 115 16 x 80 26 x 95 29 x 107 38 x 106 44 x 105
max. RCF 2) 3,328 3,328 3,328 3,328 2,920 3,328 3,328 3,147 3,056 3,283 3,260 3,170
radius in mm 147 147 147 147 129 147 147 139 135 145 144 140
Cat. No. tubes with screw cap - 6)
+
Adapter
Spacer
boring Ø x L in mm 17 x 107 26 x 80 30 x 90 17 x 80 26 x 72 26 x 80 29.5 x 80 16.5 x 56 26 x 83 29 x 93 38.5 x 92 45.9 x 100.5
vessels per rotor 12 4 4 4 4 4 4 16 4 4 4 4
Cat. No. 1356 1365 1384 6311 1363 1365 6318 1348 4417 4416 1396 0765
75
UNIVERSAL 320 | 320 R | BENCHTOP CENTRIFUGES
Rotor Bucket
max. RPM | max. RCF
max. capacity
run-up | run-down, braked in sec
4,500 min-1 | 3,305
4 x 50 ml
27 | 30
+ Cat. No. 1398
Vessels
capacity in ml 5 6 7 9 12 15 2.6–3.4 2.7–3 4–5.5 4.5–5 4.9 9 – 10 10 1.6 – 5 4–7
Ø x L in mm 12 x 75 12 x 82 12 x 100 14 x 100 17 x 102 17 x 100 13 x 65 11 x 66 15 x 75 11 x 92 13 x 90 16 x 92 15 x 102 13 x 75 13 x 100
max. RCF 2) 3,147 3,147 3,147 3,192 3,102 3,192 3,147 3,147 2,875 3,147 3,147 3,192 3,192 3,147 3,147
radius in mm 139 139 139 141 137 141 139 139 127 139 139 141 141 139 139
Cat. No. Tubes 2) blood collection / urine vessels
+
+ 0716
Adapter
boring Ø x L in mm 13.4 x 57.5 13.4 x 57.5 13.4 x 57.5 17.5 x 81 17.5 x 74 17.5 x 81 13.4 x 57.5 13.4 x 57.5 17.5 x 81 13.4 x 57.5 13.4 x 57.5 17.5 x 81 17.5 x 81 13.4 x 57.5 13.4 x 57.5
vessels per rotor 20 20 20 16 12 16 20 20 16 20 20 16 16 20 20
Cat. No. 1486 1486 1486 1482A 1487 1482A 1486 1486 1482A 1486 1486 1482A 1482A 1486 1486
Vessels
capacity in ml 4–7 8.5 – 10 15 50 12 50
Ø x L in mm 16 x 75 16 x 100 17 x 120 29 x 115 17 x 100 29 x 115
max. RCF 2) 3,034 3,034 3,305 3,260 3,192 3,260
radius in mm 134 134 146 144 141 144
Cat. No. blood collection / tubes with screw cap
+
urine vessels
+ 0716 + 0716
Adapter
boring Ø x L in mm 17.5 x 81 17.5 x 81 17 x 100 30 x 98 17.5 x 81 30 x 98
vessels per rotor 16 16 16 4 16 4
Cat. No. 1482A 1482A 1483A 1484 1482A 1484 4)
1) For cooled versions: Lowest temperature achievable with precooling and max. speed.
2) Please note that the RCF values indicated refer only to rotor performance. The max. permissible RCF of tubes used should be verified with the individual manufacturers.
The max. RCF for glass tubes annotated with footnote 2) is 4,000.
4) Please remove spacer.
76
SWING-OUT ROTOR, 8-PLACE | 1611
Rotor
max. RPM | max. RCF 4,000 min-1 | 2,415
UNIVERSAL
320 | 320 R
max. capacity 8 x 15 ml
run-up | run-down, braked in sec 20 | 20
angle | max. noise level 90° | 48 dB (A)
temperature in °C 1) -16
Cat. No. 1611
Vessels
capacity in ml 5 6 7 10 15 2.6 – 3.4 2.7 – 3 4 – 5.5 4.5 – 5 7.5 – 8.5 1.6 – 5 4–7 4–7 8.5 – 10
Ø x L in mm 12 x 75 12 x 82 12 x 100 13 x 100 17 x 100 13 x 65 11 x 66 15 x 75 11 x 92 15 x 92 13 x 75 13 x 100 16 x 75 16 x 100
max. RCF 2) 1,914 1,914 2,415 2,415 2,415 1,914 1,914 1,914 2,415 2,415 1,914 2,415 1,914 2,415
radius in mm 107 107 135 135 135 107 107 107 135 135 107 135 107 135
Cat. No. tubes 2) blood collection / urine vessels
+
Bucket
boring Ø x L in mm 13 x 53 13 x 53 13.2 x 81 13.2 x 81 17.5 x 81 13 x 53 13 x 53 17.5 x 53 13.2 x 81 17.5 x 81 13 x 53 13.2 x 81 17.5 x 53 17.5 x 81
vessels per rotor 8 8 8 8 8 8 8 8 8 8 8 8 8 8
Cat. No. 1131-A 1131-A 1643 1643 1644 1131-A 1131-A 1132-A 1643 1644 1131-A 1643 1132-A 1644
Rotor
max. RPM | max. RCF 2) 5,000 min-1 | 4,193
max. capacity 12 x 15 ml
run-up | run-down, braked in sec 16 | 16
angle | max. noise level 55°/ 60°/ 80° | 54 dB (A)
Cat. No. 1628
Vessels
capacity in ml 5 15 2.6 – 3.4 2.7 – 3 4 – 5.5 7.5 – 8.5 1.6 – 5 4–7 8.5 – 10
Ø x L in mm 12 x 75 17 x 100 13 x 65 11 x 66 15 x 75 15 x 92 13 x 75 16 x 75 16 x 100
max. RCF 2) 3,494 4,193 3,494 3,494 3,522 4,193 3,494 3,522 4,193
radius in mm 125 150 125 125 126 150 125 126 150
temperature in °C 1) -15 -10 -15 -15 -15 -10 -15 -15 -10
Cat. No. tubes 2)
blood collection / urine vessels
+
Bucket
1)
2)
For cooled versions: Lowest temperature
achievable with precooling and max. speed.
Please note that the RCF values indicated
refer only to rotor performance. The max.
boring Ø x L in mm 13.2 x 53 17.5 x 79 13.2 x 53 13.2 x 53 17.5 x 53 17.5 x 79 13.2 x 53 17.5 x 53 17.5 x 79 permissible RCF of tubes used should be
vessels per rotor 12 12 12 12 12 12 12 12 12 verified with the individual manufacturers.
The max. RCF for glass tubes annotated with
Cat. No. 1127-A 1621 1127-A 1127-A 1122 1621 1127-A 1122 1621 footnote 2) is 4,000.
77
UNIVERSAL 320 | 320 R | BENCHTOP CENTRIFUGES
Rotor
max. RPM | max. RCF 5,000 min-1 | 3,857
max. capacity 8 x 50 ml
run-up | run-down, braked in sec 20 | 19
angle | max. noise level 45° | 50 dB (A)
temperature in °C 1) -10
Cat. No. 1617
Vessels
capacity in ml 15 50
Ø x L in mm 17 x 120 29 x 115
max. RCF 2) 3,857 3,857
radius in mm 138 138
Cat. No. tubes with
+
screw cap
Adapter
boring Ø x L in mm 17 x 84 30 x 94.5
vessels per rotor 8 8
Cat. No. 1462-A -
Rotor
max. RPM | max. RCF 4,000 min-1 | 2,701
max. capacity 6 x 50 ml
run-up | run-down, braked in sec 20 | 22
angle | max. noise level 90° | 50 dB (A)
temperature in °C 1) -15
Cat. No. 1619
Vessels
capacity in ml 15 50
Ø x L in mm 17 x 120 29 x 115
max. RCF 2) 2,701 2,701
radius in mm 151 151
Cat. No. tubes with
+
screw cap
78
SWING-OUT ROTOR, 2-PLACE | 1460
Rotor
max. RPM | max. RCF 4,000 min-1 | 2,218
UNIVERSAL
320 | 320 R
max. capacity 10 plates
run-up | run-down, braked in sec 40 | 45
angle | max. noise level 90° | 55 dB (A)
temperature in °C 1) -6
Cat. No. 1460
Vessels
capacity in ml - - - - - - - - 0.2
W x D x H in mm 128x86x15 128x86x17.5 128 x 86 x 22 128 x 86 x 44.5 128 x 86 x 46 128 x 86 x 83 84 x 59 x 11 124 x 82 x 20 -
max. RCF 2) 2,218 2,218 2,218 2,218 2,218 2,218 2,218 2,218 2,218
radius in mm 124 124 124 124 124 124 124 124 124
Cat. No. MTP MTP CP DWP MS QP Microtest PCR plate, PCR strips
+
plates 96 wells
Bucket
boring Ø x L in mm - - - - - - - - -
vessels per rotor 10 8 6 2 2 2 4 2 24 x 8
Cat. No. 1453-A 1453-A 1453-A 1453-A 1453-A 1453-A 1453-A 1453-A + 1485 1453-A + 1485
Lid bioseal5),
Rotor phenol-resistant
max. RPM | max. RCF
max. capacity
run-up | run-down, braked in sec
13,000 min-1 | 18,327
24 x 2 ml
36 | 31
+ Cat. No. INCLUSIVE
angle 90°
temperature in °C 1) 3
Cat. No. 1555
Vessels
capacity in ml 0.2 0.4 0.5 0.8 1.5 2
Ø x L in mm 6 x 18 6 x 45 8 x 30 8 x 45 11 x 38 11 x 38
max. RCF 2) 18,327 18,327 18,327 18,327 18,327 18,327 1) For cooled versions: Lowest temperature
radius in mm 97 97 97 97 97 97 achievable with precooling and max. speed.
Cat. No. microliter tubes 2) Please note that the RCF values indicated
+
refer only to rotor performance. The max.
permissible RCF of tubes used should be
verified with the individual manufacturers.
The max. RCF for glass tubes annotated with
footnote 2) is 4,000.
Adapter
5) Tested by TÜV in conformity with DIN EN
boring Ø x L in mm 6 x 40 6 x 40 8 x 40 8 x 40 10.2 x 19.3 11.5 x 38.5 61010, section 2 - 020.
vessels per rotor 24 24 24 24 24 24 7) For centrifugation at high speeds, we
recommend to use conical, phenol-resistant
Cat. No. 2024 2024 2023 2023 20317) - adapters. Cat. No. 2031.
79
UNIVERSAL 320 | 320 R | BENCHTOP CENTRIFUGES
+
Lid bioseal5),
Rotor phenol-resistant
max. RPM | max. RCF 16,000 min-1 | 24,900 Cat. No. INCLUSIVE
max. capacity 24 x 2 ml
run-up | run-down, braked in sec 30 | 29
angle | max. noise level 50° | 58 dB (A)
temperature in °C 1) 2
Cat. No. 1552
Vessels
capacity in ml 0.2 0.4 0.5 0.8 1.5 2 0.5
Ø x L in mm 6 x 18 6 x 45 8 x 30 8 x 45 11 x 38 11 x 38 10,7 x 36
max. RCF 2) 24,900 24,900 24,900 24,900 24,900 24,900 23,755
radius in mm 87 87 87 87 87 87 83
Cat. No. microliter tubes Pediatric
+
Adapter
boring Ø x L in mm 6 x 40 6 x 40 8 x 40 8 x 40 10.2 x 19.3 11.2 x 42.6 11.2 x 39
vessels per rotor 24 24 24 24 24 24 12
Cat. No. 2024 2024 2023 2023 20317) - 0788 17)
+
Lid bioseal5),
Rotor phenol-resistant
max. RPM | max. RCF 14,150 min-1 | 21,713 Cat. No. INCLUSIVE
max. capacity 30 x 2 ml
run-up | run-down, braked in sec 35 | 32
angle 45°
temperature in °C 1) -1
Cat. No. 1553
Vessels
capacity in ml 0.2 0.4 0.5 0.8 1.5 2 0.5
Ø x L in mm 6 x 18 6 x 45 8 x 30 8 x 45 11 x 38 11 x 38 10.7 x 36
1) For cooled versions: Lowest temperature
max. RCF 2) 21,713 21,713 21,713 21,713 21,713 21,713 20,818 achievable with precooling and max. speed.
radius in mm 97 97 97 97 97 97 93 2) Please note that the RCF values indicated
refer only to rotor performance. The max.
Cat. No. microliter tubes Pediatric
+
permissible RCF of tubes used should be
verified with the individual manufacturers.
The max. RCF for glass tubes annotated with
footnote 2) is 4,000.
5) Tested by TÜV in conformity with DIN EN
Adapter 61010, section 2 - 020.
boring Ø x L in mm 6 x 40 6 x 40 8 x 40 8 x 40 10.2 x 19.3 11.2 x 40.9 11.2 x 39 7) For centrifugation at high speeds, we
vessels per rotor 30 30 30 30 30 30 15 recommend to use conical, phenol-resistant
adapters. Cat. No. 2031.
Cat. No. 2024 2024 2023 2023 20317) - 0788 17) 17) Packed in units of 15 pieces.
80
ANGLE ROTOR, 8-PLACE | 1551
+
Lid bioseal5),
Rotor phenol-resistant
max. RPM | max. RCF 13,000 min-1 | 13,604 Cat. No. INCLUSIVE
UNIVERSAL
320 | 320 R
max. capacity 8 x PCR-Strips
run-up | run-down, braked in sec 36 | 31
angle | max. noise level 45° | 58 dB (A)
temperature in °C 1) -4
Cat. No. 1551
Vessels
capacity in ml 0.2 0.2
Ø x L in mm 6 x 18 -
max. RCF 2) 13,604 13,604
radius in mm 72 72
Cat. No. - PCR-
Strips
+
Lid bioseal5),
Rotor phenol-resistant
max. RPM | max. RCF 14,150 min-1 | 22,161 Cat. No. INCLUSIVE
max. capacity 18 x 5 ml
run-up | run-down, braked in sec 35 | 32
angle 45°
temperature in °C 1) 2
Cat. No. 1627
Vessels
capacity in ml 5
Ø x L in mm 17 x 59
max. RCF 2) 22,161
radius in mm 99
Cat. No. - 1) For cooled versions: Lowest temperature
achievable with precooling and max. speed.
2) Please note that the RCF values indicated
refer only to rotor performance. The max.
permissible RCF of tubes used should be
verified with the individual manufacturers.
The max. RCF for glass tubes annotated with
footnote 2) is 4,000.
5) Tested by TÜV in conformity with DIN EN
61010, section 2 - 020.
81
UNIVERSAL 320 | 320 R | BENCHTOP CENTRIFUGES
+
Lid bioseal5),
Rotor phenol-resistant
max. RPM | max. RCF 9.000 min-1 | 10.595 Cat. No. INCLUSIVE
max. capacity 6 x 94 ml
run-up | run-down, braked in sec 36 | 32
angle | max. noise level 35° | 60 dB (A)
temperature in °C 1) 0
Cat. No. 1556
Vessels
capacity in ml 1.5 2 15 50 50 85 7.5 – 8.5 9 – 10 10 8.5 – 10 15 50 10 30 50
Ø x L in mm 11 x 38 11 x 38 17 x 100 35 x 105 34 x 100 38 x 101 15 x 92 16 x 92 15 x 102 16 x 100 17 x 120 29 x 115 16 x 80 26 x 95 29 x 107
max. RCF 2) 10,324 10,324 10,052 10,414 10,414 10,595 10,052 10,052 10,052 10,052 10,052 10,052 10,414 9,690 10,142
radius in mm 114 114 111 115 115 117 111 111 111 111 111 111 115 107 112
Cat. No. microliter tubes tubes 2) blood collection / urine vessels tubes with screw cap
+
Adapter
boring Ø x L in mm 11.4 x 39 11.4 x 39 17.5 x 78 35 x 89 35 x 89 - 17.5 x 78 17.5 x 78 17.5 x 78 17.5 x 78 17 x 106 29.8 x 97 16.5 x 72 26 x 85 29 x 92
vessels per rotor 24 24 6 6 6 6 6 6 6 6 6 6 12 6 6
Cat. No. 1449 1449 1478 1463 1463 - 1478 1478 1478 1478 1466 1454 1477 1447 1446
Vessels
capacity in ml 85 94
Ø x L in mm 38 x 106 38 x 102
max. RCF 2) 10,595 10,595
radius in mm 117 117
Cat. No. tubes with
+
screw cap
Adapter
boring Ø x L in mm - -
vessels per rotor 6 6
Cat. No. - -
1) For cooled versions: Lowest temperature achievable with precooling and max. speed.
2) Please note that the RCF values indicated refer only to rotor performance. The max. permissible RCF of tubes used should be verified with the individual manufacturers.
The max. RCF for glass tubes annotated with footnote 2) is 4,000.
5) Tested by TÜV in conformity with DIN EN 61010, section 2 - 020.
82
ANGLE ROTOR, 12-PLACE | 1613
Rotor
max. RPM | max. RCF 6,000 min-1 | 4,146
UNIVERSAL
320 | 320 R
max. capacity 12 x 15 ml
run-up | run-down, braked in sec 15 | 15
angle | max. noise level 35° | 50 dB (A)
temperature in °C 1) -16
Cat. No. 1613
Vessels
capacity in ml 0.5 1.5 2.0 4 5 6 15 1.1 – 1.4 2.6 – 3.4 2.7 – 3 4.5 – 5 4.9 7.5 – 8.5 9 – 10 10
Ø x L in mm 10.7 x 36 11 x 38 11 x 38 10 x 88 12 x 75 12 x 82 17 x 100 8 x 66 13 x 65 11 x 66 11 x 92 13 x 90 15 x 92 16 x 92 15 x 102
max. RCF 2) 2,777 2,737 2,737 3,502 3,300 3,300 4,146 3,300 3,300 3,300 4,146 4,146 4,146 4,146 4,146
radius in mm 69 68 68 87 82 82 103 82 82 82 103 103 103 103 103
Cat. No. Pediatric microliter tubes tubes 2) blood collection / urine vessels
+
Adapter
boring Ø x L in mm 11 x 35 11 x 35 11 x 35 11.5 x 67.5 13.5 x 60 13.5 x 60 17.7 x 88 13.5 x 60 13.5 x 60 13.5 x 60 17.7 x 88 17.7 x 88 17.7 x 88 17.7 x 88 17.7 x 88
vessels per rotor 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12
Cat. No. 2 x 1063-6 (6 pcs.) 6305 1054-A 1054-A - 1054-A 1054-A 1054-A - - - -
Vessels
capacity in ml 1.6 – 5 4–7 8 8.5 – 10 5 15
Ø x L in mm 13 x 75 13 x 100 16 x 125 16 x 100 17 x 59 17 x 120
max. RCF 2) 3,300 4,146 4,146 4,146 3,180 4,146
radius in mm 82 103 103 103 79 103
Cat. No. blood collection / urine vessels - -
+
Adapter
boring Ø x L in mm 13.5 x 60 13.5 x 79 17.7 x 88 17.7 x 88 17 x 25 17.7 x 88
vessels per rotor 12 12 6 12 12 6
Cat. No. 1054-A 1058 - - 1064 -
1) For cooled versions: Lowest temperature achievable with precooling and max. speed.
2) Please note that the RCF values indicated refer only to rotor performance. The max. permissible RCF of tubes used should be verified with the individual manufacturers.
The max. RCF for glass tubes annotated with footnote 2) is 4,000.
83
UNIVERSAL 320 | 320 R | BENCHTOP CENTRIFUGES
Rotor
max. RPM | max. RCF 12,000 min-1 | 16,582
max. capacity 12 x 15 ml
run-up | run-down, braked in sec 40 | 40
angle | max. noise level 35° | 52 dB (A)
temperature in °C 1) -2
Cat. No. 1615
Vessels
capacity in ml 0.5 1.5 2.0 4 5 6 15 1.1 - 1.4 2.6 - 3.4 2.7 - 3 4.5 - 5 4.9 7.5 - 10 10
Ø x L in mm 10.7 x 36 11 x 38 11 x 38 10 x 88 12 x 75 12 x 82 17 x 100 8 x 66 13 x 65 11 x 66 11 x 92 13 x 90 15/16 x 92 15 x 102
max. RCF 2) 11,108 10,947 10,947 14,006 13,201 13,201 16,582 13,201 13,201 13,201 16,582 16,582 16,582 16,582
radius in mm 69 68 68 87 82 82 103 82 82 82 103 103 103 103
Cat. No. Pediatric microliter tubes tubes 2) blood collection / urine vessels
+
Adapter
boring Ø x L in mm 11 x 35 11 x 35 11 x 35 11.5x67.5 13.5 x 60 13.5 x 60 17.7 x 88 13.5 x 60 13.5 x 60 13.5 x 60 17.7 x 88 17.7 x 88 17.7 x 88 17.7 x 88
vessels per rotor 12 12 12 12 12 12 12 12 12 12 12 12 12 12
Cat. No. 2 x 1063-6 (6 pcs.) 6305 1054-A 1054-A - 1054-A 1054-A 1054-A - - - -
Vessels
capacity in ml 1.6 – 5 4–7 8 – 10 8 – 10 5 15
Ø x L in mm 13 x 75 13 x 100 16 x 100 16 x 125 17 x 59 17 x 120
max. RCF 2) 13,201 16,582 16,582 16,582 12,718 15,455
radius in mm 82 103 103 103 79 96
Cat. No. blood collection / urine vessels - -
+
Adapter
boring Ø x L in mm 13.5 x 60 13.5 x 79 17.7 x 88 17.7 x 88 17 x 25 17 x 104
vessels per rotor 12 12 12 6 12 6
Cat. No. 1054-A 1058 - - 1064 1647 25)
1) For cooled versions: Lowest temperature achievable with precooling and max. speed.
2) Please note that the RCF values indicated refer only to rotor performance. The max. permissible RCF of tubes used should be verified with the individual manufacturers.
The max. RCF for glass tubes annotated with footnote 2) is 4,000.
25) Adapter (set), 6-place: For conical 15 ml tubes with screw cap, remove carriers from rotor and replace them with adapters.
84
ANGLE ROTOR, 8-PLACE | 1418
Rotor
max. RPM | max. RCF 4,500 min-1 | 3,305
UNIVERSAL
320 | 320 R
max. capacity 8 x 50 ml
run-up | run-down, braked in sec 30 | 31
angle | max. noise level 45° | 54 dB (A)
temperature in °C 1) -11
Cat. No. 1418
Vessels
capacity in ml 5 15 1.1 – 1.4 2.6 – 3.4 2.7 – 3 9 – 10 1.6 – 5 4 – 7 8.5 – 10 12 15 50 12 50 50
Ø x L in mm 12 x 75 17 x 100 8 x 66 13 x 65 11 x 66 16 x 92 13 x 75 13 x 100 16 x 100 17 x 102 17 x 120 29 x 115 17 x 100 29 x 115 29 x 107
max. RCF 2) 2,762 3,215 2,762 2,762 2,762 3,215 2,762 3,305 3,215 3,215 3,283 3,147 3,215 3,147 3,147
radius in mm 122 142 122 122 122 142 122 146 142 142 145 139 142 139 139
Cat. No. tubes 2) blood collection / urine vessels tubes with screw cap
+
+ 1054-A + 0716 + 1054-A + 1054-A + 1054-A + 0716 + 1054-A + 0716 + 0716 + E2109 + E2110-A + 0716
Carrier
boring Ø x L in mm 17.4 x 91 17.4 x 91 17.4 x 91 17.4 x 91 17.4 x 91 17.4 x 91 17.4 x 91 17.4 x 91 17.4 x 91 17.4 x 91 17.4 x 91 30.2 x 92 17.4 x 91 30.2 x 92 30.2 x 92
vessels per rotor 32 32 32 32 32 32 32 32 32 32 32 8 32 8 8
Cat. No. 1467 1467 1467 1467 1467 1467 1467 1467 1467 1467 1467 1468 1467 1468 1468
1) For cooled versions: Lowest temperature achievable with precooling and max. speed.
2) Please note that the RCF values indicated refer only to rotor performance. The max. permissible RCF of tubes used should be verified with the individual manufacturers.
The max. RCF for glass tubes annotated with footnote 2) is 4,000.
85
UNIVERSAL 320 | 320 R | BENCHTOP CENTRIFUGES
PACKAGES
UNIVERSAL 320 number of
BLOOD TUBE PACKAGE 1 vessels volume (ml) size (mm) RPM RCF
- 1 x UNIVERSAL 320 centrifuge 1401 28 1.6 - 7 13 x 75 / 100 5,000 3,913
- 1 x swing-out rotor, 4-place 1494 28 4 - 10 16 x 75 / 100 5,000 3,913
- 4 x bucket 1425
- 4 x adapter, 7-place 1438
- 4 x adapter, 7-place 1441
1401SET1
1401SET3
1406SET2
1406SET3
86
UNIVERSAL 320 R number of
BLOOD TUBE PACKAGE 5 vessels volume (ml) size (mm) RPM RCF
- 1 x UNIVERSAL 320 R centrifuge 1406 28 1.6 - 7 13 x 75 / 100 5,000 3,913
- 1 x swing-out rotor, 4-place 1554 28 4 - 10 16 x 75 / 100 5,000 3,913
- 4 x bucket 1560
- 4 x lid (biodicht) 1561
UNIVERSAL
320 | 320 R
- 4 x adapter, 7-place 1589
- 4 x adapter, 5-place 1588
1406SET5
87
ROTINA 380 | 380 R
High speed with space saving design
High performance unit supporting a wide array of accessories for multiple applications in just one rotor. Its size and performance
make it the ideal benchtop centrifuge for most clinical, reaearch and industrial laboratories. This unit is available with refrigerati-
on and a temperature range from -20 °C to +40 °C (ROTINA 380 R).
88
TECHNICAL DATA
ROTINA 380 ROTINA 380 R
non-refrigerated refrigerated
voltage *) 200 – 240 V 1 ~ 200 – 240 V 1 ~
frequency 50 – 60 Hz 50 – 60 Hz
AVAILABLE ROTORS
SWING-OUT ROTORS angle max. RPM max. capacity Cat. No. page
ANGLE ROTORS
10,000 |
angle rotor, 6-place 45° 6 x 94 ml 1720 97
11,000 min-1
10,000 |
angle rotor, 6-place 45° 6 x 94 ml 1792 98
11,000 min-1
89
ROTINA 380 | 380 R | BENCHTOP CENTRIFUGES
+
Rotor Bucket
max. RPM | max. RCF 5,000 min-1 | 4,863 lid bioseal 5) 1751
max. capacity 4 x 290 ml Cat. No. 1752
run-up | run-down, braked in sec 42 | 27
angle | max. noise level 90° | 60 dB (A)
temperature in °C 1) 0
Cat. No. 1754
Vessels
capacity in ml 1.5 2.0 3 4 5 6 7 9 15 20 25 45 50 94 100
Ø x L in mm 11 x 38 11 x 38 10 x 60 12 x 60 12 x 75 12 x 82 12 x 100 14 x 100 17 x 100 21 x 100 24 x 100 31 x 100 34 x 100 38 x 102 40 x 115
max. RCF 2) top / bottom 3,494 / 3,494 / 4,779 4,668 4,668 4,668 4,668 4,668 4,668 4,668 4,668 4,668 4,668 4,807 4,640
4,779 4,779
radius in mm top / bottom 125 / 171 125 / 171 171 167 167 167 167 167 167 167 167 167 167 172 166
Cat. No. microliter tubes tubes 2)
+
Adapter
boring Ø x L in mm 11.2 x 39.5 11.2 x 39.5 11.2 x 39.5 12.5 x 56 12.5 x 56 12.5 x 56 12.5 x 56 17.5 x 62 17.5 x 62 25.5 x 81 25.5 x 81 35.5 x 81 35.5 x 81 38.5 x 80 41 x 97
vessels per rotor 144 144 72 96 96 96 96 52 52 24 24 12 12 8 4
Cat. No. 1761 1761 1761 1762-A 1762-A 1762-A 1762-A 1763-A 1763-A 1764 1764 1765 1765 1777 1767
Vessels
capacity in ml 100 250 1.1–1.4 2.6–3.4 2.7–3 4–5.5 4.5–5 4.5–5 4.9 4.9 7.5–8.5 9–10 10 1.6–5 4– 7
Ø x L in mm 44 x 100 65 x 115 8 x 66 13 x 65 11 x 66 15 x 75 11 x 92 11 x 92 13 x 90 13 x 90 15 x 92 16 x 92 15 x 102 13 x 75 13 x 100
max. RCF 2) 4,640 4,640 4,668 4,668 4,668 4,668 4,668 4,668 4,668 4,668 4,668 4,668 4,668 4,668 4,668
radius in mm 166 166 167 167 167 167 167 167 167 167 167 167 167 167 167
Cat. No. tubes 2) blood collection tubes / urine tubes
+
Adapter
boring Ø x L in mm 45 x 87 66 x 104.5 9 x 49 13.5 x 54 12.5 x 56 17.5 x 62 12.5 x 56 13.2 x 72 13.5 x 54 13.2 x 72 17.5 x 62 17.5 x 62 17.5 x 62 13.5 x 54 13.5 x 54
vessels per rotor 4 4 96 64 96 52 96 76 64 76 52 52 52 64 64
Cat. No. 1766 1768 1781 1783-A 1762-A 1763-A 1762-A 1787 1783-A 1787 1763-A 1763-A 1763-A 1783-A 1783-A
1) For cooled versions: Lowest temperature achievable with precooling and max. speed.
2) Please note that the RCF values indicated refer only to rotor performance. The max. permissible RCF of tubes used should be verified with the individual manufacturers.
The max. RCF for glass tubes annotated with footnote 2) is 4,000.
5) Tested by TÜV in conformity with DIN EN 61010, section 2 - 020.
90
SWING-OUT ROTOR, 4-PLACE | 1754
+
Rotor Bucket
Vessels
capacity in ml 4–7 4–7 8 8.5 – 10 5 15 50 12 25 30 50 50 14 10 30
Ø x L in mm 13 x 100 16 x 75 16 x 125 16 x 100 17 x 59 17 x 120 29 x 115 17 x 100 25 x 90 25 x 110 29 x 115 29 x 115 16,5 x 106 16 x 80 26 x 95
max. RCF 2) 4,668 4,668 4,668 4,668 4,863 4,863 4,863 4,696 4,528 4,528 4,752 4,752 4,668 4,668 4,807
radius in mm 167 167 167 167 174 174 174 168 162 162 170 170 167 167 172
Cat. No. blood collection tubes / urine tubes - tubes with screw cap
+
21)
+ E2110-A
Adapter
boring Ø x L in mm 13.2 x 72 17.5 x 62 17.5 x 62 17.5 x 62 17 x 52 17 x 84 30 x 84 17 x 78 26.5 x 72 26.5 x 72 30 x 80 30 x 80 17.5 x 62 17.5 x 62 26.5 x 70
vessels per rotor 76 52 12 52 32 36 16 36 20 20 16 16 52 52 24
Cat. No. 1787 1763-A 1763-A 1763-A 1738 1771-A 1772-A 1773 1779 1779 1774-A 1774-A 1763-A 1763-A 1775
3.3) 3.3)
Vessels
capacity in ml 50 85 94 175 175 200 225 250 290
Ø x L in mm 29 x 107 38 x 106 38 x 102 61 x 118 62 x 144 60 x 130 61 x 137 61 x 122 62 x 137
max. RCF 2) 4,752 4,807 4,807 4,863 4,863 4,863 4,863 4,863 4,863
radius in mm 170 172 172 174 174 174 174 174 174
Cat. No. tubes with screw cap Falcon Nalgene Nunc® Falcon 5127 24) - 24)
+
Adapter
boring Ø x L in mm 30 x 80 38.5 x 80 38.5 x 80 62 x 111 62 x 111 62 x 111 62 x 111 62 x 100 62 x 100
vessels per rotor 16 8 8 4 4 4 4 4 4
Cat. No. 1774-A 1777 1777 1782 1778 1778 1782 1769 1769
1) For cooled versions: Lowest temperature achievable with precooling and max. speed.
2) Please note that the RCF values indicated refer only to rotor performance. The max. permissible RCF of tubes used should be verified with the individual manufacturers.
The max. RCF for glass tubes annotated with footnote 2) is 4,000.
3.3) When using these tubes, bucket 1752 or 5051 cannot be closed with lid 1751 or 5053.
5) Tested by the TÜV in conformity with DIN EN 61010, section 2 - 020.
21) Adapter must be loaded as illustrated.
24) At temperatures of over +40 °C and / or when not filled to capacity, bottles may warp during centrifugation.
91
ROTINA 380 | 380 R | BENCHTOP CENTRIFUGES
+
Rotor Bucket
max. RPM | max. RCF 4,000 min-1 | 2,898 lid 5053
max. capacity 4 x 100 ml Cat. No. 5051
run-up | run-down, braked in sec 24 | 17
angle | max. noise level 90° | 55 dB (A)
temperature in °C 1) -8
Cat. No. 1798
Vessels
capacity in ml 1.5 2 1.5 2 3 5 6 7 9 15 25 50 100 100
Ø x L in mm 11 x 38 11 x 38 11 x 38 11 x 38 10 x 60 12 x 75 12 x 82 12 x 100 14 x 100 17 x 100 24 x 100 34 x 100 40 x 115 44 x 100
max. RCF 2) top / bottom 1,950 / 1,950 / 2,826 2,826 2,737 2,773 2,773 2,755 2,773 2,755 2,755 2,755 2,755 2,755
2,826 2,826
radius in mm 109 / 158 109 / 158 158 158 153 155 155 154 155 154 154 154 154 154
Cat. No. microliter tubes tubes 2)
+
Adapter
boring Ø x L in mm 12.5 x 42 12.5 x 42 11.5 x 50 11.5 x 50 11 x 44 12.5 x 42 12.5 x 42 12.5 x 86 16 x 50 17.5 x 86 26 x 86 36 x 86 42 x 86 45.5 x 86
vessels per rotor 160 160 64 64 80 80 80 80 48 48 20 8 4 4
Cat. No. 5257 5257 5281 5281 5267 5227 5227 5247 15) 5264 5248 15) 5242 5243 5249 5262
3.3)
Vessels
capacity in ml 1.1 – 1.4 2.6 – 3.4 2.7 – 3 4 – 5.5 4.5 – 5 4.9 7.5 – 8.5 9 – 10 10 1.6 – 5 4 – 7 4 – 7 8.5 – 10
Ø x L in mm 8 x 66 13 x 65 11 x 66 15 x 75 11 x 92 13 x 90 15 x 92 16 x 92 15 x 102 13 x 75 13 x 100 16 x 75 16 x 100
max. RCF 2) 2,737 2,808 2,773 2,773 2,773 2,808 2,773 2,755 2,755 2,808 2,808 2,773 2,755
radius in mm 153 157 155 155 155 157 155 154 154 157 157 155 154
Cat. No. blood collection tubes / urine tubes
+
Adapter
boring Ø x L in mm 11 x 44 13.5 x 52 12.5 x 42 16 x 50 12.5 x 42 13.5 x 52 16 x 50 17.6 x 86 17.6 x 86 13.5 x 52 13.5 x 52 16 x 50 17.5 x 86
vessels per rotor 80 48 80 48 80 48 48 44 44 48 48 48 48
Cat. No. 5267 5268 5227 5264 5227 5268 5264 5258 5258 5268 5268 5264 5248
+
+ 2 x 6316 precooling and max. speed.
2) Please note that the RCF values indicated refer only to
rotor performance. The max. permissible RCF of tubes
used should be verified with the individual manufacturers.
The max. RCF for glass tubes annotated with footnote 2) is
Adapter
4,000.
boring Ø x L in mm 26 x 86 30 x 86 17 x 90 17 x 90 26 x 86 36 x 86 - 3.3) When using these tubes, bucket 1752 or 5051 cannot be
vessels per rotor 20 8 28 28 20 8 8 closed with lid 1751 or 5053.
15) Also available with decanting aid. (Cat. No. 5247-91 or
Cat. No. 5266 5259 6306 6306 5266 5243 5280 5248-91).
92
SWING-OUT ROTOR, 4-PLACE | 1798
+
Rotor Bucket
Vessels
capacity in ml 5 6 7 15 25 50 100 100 250 15 30 50 12 25 30
Ø x L in mm 12 x 75 12 x 82 12 x 100 17 x 100 24 x 100 34 x 100 44 x 100 40 x 115 65 x 115 17 x 120 25 x 110 29 x 115 17 x 100 25 x 90 25 x 110
max. RCF 2) 3,005 3,005 3,005 2,952 2,898 2,952 2,952 2,952 3,095 3,095 2,898 3,095 3,005 2,826 2,898
radius in mm 168 168 168 165 162 165 165 165 173 173 162 173 168 158 162
Cat. No. tubes 2) tubes with screw cap
+
Adapter
boring Ø x L in mm 12.8 x 45 12.8 x 45 13.2x82 17.5 x 60.7 25.5 x 82 35.5 x 85 45.5 x 85 42 x 85 66 x 103 17 x 85 25.5 x 82 30 x 85 17.5 x 82 26 x 73 25.5 x 82
vessels per rotor 48 48 48 32 16 4 4 4 4 28 16 8 28 12 16
Cat. No. 5128 5128 5120 5136 5122 5124 5125 5126 1791 5129 5122 5123 5121 5134 5122
3.5)
Vessels
capacity in ml 50 10 250 290 1.1–1.4 2.6–3.4 2.7–3 4–5.5 4.5–5 4.9 7.5–8.5 9 – 10 10 1.6 – 5 4–7
Ø x L in mm 29 x 115 16 x 80 61 x 122 62 x 137 8 x 66 13 x 65 11 x 66 15 x 75 11 x 92 13 x 90 15 x 92 16 x 92 15 x 102 13 x 75 16 x 75
max. RCF 2) 3,023 2,952 3,095 3,095 2,540 2,540 2,540 2,952 3,005 2,952 2,952 2,952 2,952 2,540 2,952
radius in mm 169 165 173 173 142 142 142 165 168 165 165 165 165 142 165
Cat. No. tubes with 5127 24) - 24) blood collection tubes / urine tubes
+
screw cap
Adapter
boring Ø x L in mm 30 x 99 17.5 x 60.7 66 x 103 66 x 103 13.2x54.5 13.2x54.5 13.2x54.5 17.5 x 60.7 13.2x82 13.5 x 60.7 17.5 x 60.7 17.5 x 60.7 17.5 x 60.7 13.2x54.5 17.5 x 60.7
vessels per rotor 8 32 4 4 48 48 48 32 48 32 32 32 32 48 32
Cat. No. 5135 5136 6319 6319 5138 5138 5138 5136 5120 5137 5136 5136 5136 5138 5136
3.5)
Vessels
capacity in ml 4–7 8 8.5 – 10
Ø x L in mm 13 x 100 16 x 125 16 x 100
max. RCF 2) 3,005 3,059 2,952
radius in mm 168 171 165
Cat. No. blood collection / urine tubes 1) For cooled versions: Lowest temperature achievable with precooling and
+
max. speed.
2) Please note that the RCF values indicated refer only to rotor performan-
ce. The max. permissible RCF of tubes used should be verified with the
individual manufacturers.
The max. RCF for glass tubes annotated with footnote 2) is 4,000.
Adapter
3.5) When using these tubes, bucket 5092 cannot be closed with lid 5053.
boring Ø x L in mm 13.2x82 17.5 x 82 17.5 x 60.7 4) Please remove the spacer.
vessels per rotor 48 28 32 5) Tested by the TÜV in conformity with DIN EN 61010, section 2 - 020.
24) At temperatures of over +40 °C and / or when not filled to capacity, bottles
Cat. No. 5120 51214) 5136 may warp during centrifugation.
93
ROTINA 380 | 380 R | BENCHTOP CENTRIFUGES
Rotor
max. RPM | max. RCF 4,000 min-1 | 2,808
max. capacity 6 x 50 ml
run-up | run-down, braked in sec 19 | 18
angle | temperature in °C 1) 90° | -6
Cat. No. 1726
Vessels
capacity in ml 5 5 6 7 9 15 20 25 45 50 8.5 x 10 30 1 – 8
Ø x L in mm 12 x 75 12 x 75 12 x 82 12 x 100 14 x 100 17 x 100 21 x 100 24 x 100 31 x 100 34 x 100 16 x 100 26 x 95 simple / multiple
max. RCF 2) 2,576 2,522 2,665 2,665 2,665 2,665 2,719 2,808 2,719 2,808 2,665 2,808 2,003
radius in mm 144 141 149 149 149 149 152 157 152 157 149 157 112
Cat. No. tubes 2) - - cyto chambers
+
with decan- with decan- with decan-
ting aid ting aid ting aid
Carrier
boring Ø x L in mm 12.5 x 64.4 13.5 x 65 12.5 x 71.5 12.5 x 71.5 14.6 x 74 17.6x71.5 21.5 x 74 26 x 78 32 x 74 35 x 78 17.6x71.5 26 x 78 -
vessels per rotor 24 102 24 24 30 24 12 12 6 6 24 12 6
Cat. No. 1369-91 1372 1369-92 1369-92 1370 1369 1346 1745 1345 1746 1369 1745 1660
+
Rotor Carrier
max. RPM | max. RCF 4,000 min-1 | 2,808 Cat. No. 1742
max. capacity 42 x 15 ml
run-up | run-down, braked in sec 19 | 18
angle | max. noise level 90° | 54 dB (A)
temperature in °C 1) -6
Cat. No. 1726
Vessels
capacity in ml 15 2.6 – 3.4 4 – 5.5 7.5 – 8.5 9 – 10 10 1.6 – 5 4 – 7 8.5 – 10 15
Ø x L in mm 17 x 100 13 x 65 15 x 75 15 x 92 16 x 92 15 x 102 13 x 75 16 x 75 16 x 100 17 x 120
max. RCF 2) 2,808 2,683 2,683 2,808 2,808 2,808 2,683 2,683 2,808 2,808
radius in mm 157 150 150 157 157 157 150 150 157 157
Cat. No. - 2) blood collection tubes / urine tubes - 1) For cooled versions: Lowest tempe-
+
rature achievable with precooling and
21) 21) max. speed.
Spacer Spacer Spacer Spacer
2) Please note that the RCF values indica-
ted refer only to rotor performance. The
Spacer max. permissible RCF of tubes used
should be verified with the individual
boring Ø x L in mm 17.6 x 78 17.6 x 78 17.6 x 78 17.6 x 78 17.6 x 78 17.6 x 78 17.6 x 78 17.6 x 78 17.6 x 78 17.6 x 78 manufacturers.
vessels per rotor 42 42 42 42 42 18 42 42 42 18 The max. RCF for glass tubes annotated
with footnote 2) is 4,000.
Cat. No. - 0716 0716 - - - 0716 0716 - -
21) Adapter must be loaded as illustrated.
94
SWING-OUT ROTOR, 6-PLACE | 1726
+
Rotor Bucket
Vessels
capacity in ml 1.5 2.0 1 3 4
Ø x L in mm 11 x 38 11 x 38 6 x 45 10 x 60 12 x 60
max. RCF 2) 2,325 2,325 2,308 2,290 2,290
radius in mm 130 130 129 128 128
Cat. No. microliter tubes Rhesus tubes 2)
+
Adapter
boring Ø x L in mm 11.5 x 38 11.5 x 38 6.5 x 23 10.5 x 23 12.5 x 44
vessels per rotor 54 54 180 72 72
Cat. No. 5277 5277 1357 1327 1326
+
Rotor Carrier
max. RPM | max. RCF 4,000 min-1 | 2,808 Cat. No. 1741
max. capacity 60 x 9 ml
run-up | run-down, braked in sec 19 | 18
angle | max. noise level 90° | 54 dB (A)
temperature in °C 1) -6
Cat. No. 1726
Vessels
capacity in ml 9 1.1 – 1.4 4.5 – 5 4.9 1.6 – 5 4–7
Ø x L in mm 14 x 100 8 x 66 11 x 92 13 x 90 13 x 75 13 x 100
max. RCF 2) 2,773 2,773 2,808 2,808 2,486 2,808
radius in mm 155 155 157 157 139 157 1) For cooled versions: Lowest tempe-
rature achievable with precooling and
Cat. No. - 2) blood collection tubes / urine tubes
+
max. speed.
2) Please note that the RCF values indica-
21)
Spacer Spacer ted refer only to rotor performance. The
max. permissible RCF of tubes used
should be verified with the individual
Adapter manufacturers.
boring Ø x L in mm 14.6 x 78 14.6 x 78 14.6 x 78 14.6 x 78 14.6 x 78 14.6 x 78 The max. RCF for glass tubes annotated
vessels per rotor 60 60 36 60 60 60 with footnote 2) is 4,000.
16) Packaging unit 10 pieces.
Cat. No. 0701 0701 - - 6x076816) - 21) Adapter must be loaded as illustrated.
95
ROTINA 380 | 380 R | BENCHTOP CENTRIFUGES
Rotor
max. RPM | max. RCF 4,000 min-1 | 2,397
max. capacity 10 plates
run-up | run-down, braked in sec 30 | 23
angle | max. noise level 90° | 54 dB (A)
temperature in °C 1) -8
Cat. No. 1760
Plates
W x D x H in mm 128 x 86 x 15 128 x 86 x 17.5 128 x 86 x 22 128 x 86 x 44.5 128 x 86 x 46 128 x 86 x 83 84 x 59 x 11 124 x 82 x 20 -
capacity in ml - - - - - - - - 0.2
max. RCF 2) 2,397 2,397 2,397 2,397 2,397 2,397 2,397 2,397 2,397
radius in mm 134 134 134 134 134 134 134 134 134
Cat. No. MTP MTP CP DWP MS QP Microtest PCR plate PCR strips
+
plates
Bucket
boring Ø x L in mm - - - - - - - - -
plates / strips per rotor 10 8 6 2 2 2 4 2 24 x 8
Cat. No. 1753-A 1753-A 1753-A 1753-A 1753-A 1753-A 1753-A 1753-A+1485 1753-A+1485
+
Rotor Bucket
max. RPM | max. RCF 5,100 min-1 | 3,926 lid bioseal 5) 4627
capacity in ml 12 plates Cat. No. 4745
run-up | run-down, braked in sec 65 | 30
angle | temperature in °C 1) 90° | -3
Cat. No. 1770
Plates
W x D x H in mm 128 x 86 x 15 128 x 86 x 17.5 128 x 86 x 22 128 x 86 x 44.5 128 x 86 x 46 128 x 86 x 83 84 x 59 x 11 124 x 82 x 20 -
Ø x L in mm - - - - - - - - 0,2
max. RCF 2) 3,926 3,926 3,926 3,926 3,926 3,926 3,926 3,926 3,926
radius in mm 135 135 135 135 135 135 135 135 135
Cat. No. MTP MTP CP DWP MS QP Microtest PCR plate PCR strips
+
plates
Removal frame
boring Ø x L in mm - - - - - - - - -
plates / strips per rotor 12 10 8 2 2 2 4 2 24 x 8
Cat. No. 4626 4626 4626 4626 4626 4626 4626 4626 + 1485 4626 + 1485
96
ANGLE ROTOR, 6-PLACE | 1720
Rotor
Vessels
capacity in ml 1.5 2.0 15 25 50 94 7.5 – 8.5 9 – 10 8.5 – 10 5 15 50 10 30 50
Ø x L in mm 11 x 38 11 x 38 17 x 100 24 x 100 34 x 100 38 x 102 15 x 92 16 x 92 16 x 100 17 x 59 17 x 120 29 x 115 16 x 80 26 x 95 29 x 107
max. RCF 2) ROTINA 380 12,969 12,969 12,745 12,410 13,304 13,528 12,745 12,745 12,745 12,857 13,081 12,745 12,410 12,410 12,969
max. RCF 2) ROTINA 380 R 15,692 15,692 15,422 15,016 16,098 16,369 15,422 15,422 15,422 15,557 15,828 15,422 15,016 15,016 15,692
radius in mm 116 116 114 111 119 121 114 114 114 115 117 114 111 111 116
Cat. No. microliter tubes tubes 2) blood collection tubes / - tubes with screw cap
+
urine tubes
Adapter
boring Ø x L in mm 11.4 x 39 11.4 x 39 17.5 x 92 26 x 85 35 x 89 38.4 x 89 17.5 x 92 17.5 x 92 17.5 x 92 17 x 51 17 x 106 29.8 x 97 16.5 x 74 26 x 85 29 x 92
vessels per rotor 24 24 6 6 6 6 6 6 6 6 6 6 12 6 6
Cat. No. 1449 1449 1451 1447 1463 - 1451 1451 1451 1476 1466 1454 1448 1447 1446
Vessels
capacity in ml 85 94
Ø x L in mm 38 x 106 38 x 102
max. RCF 2) ROTINA 380 13,528 13,528
max. RCF 2) ROTINA 380 R 16,369 16,369
radius in mm 121 121
Cat. No. tubes with
+
screw cap
Adapter
boring Ø x L in mm 38 .4x 89 38 .4x 89
vessels per rotor 6 6
Cat. No. - -
1) For cooled versions: Lowest temperature achievable with precooling and max. speed.
2) Please note that the RCF values indicated refer only to rotor performance. The max. permissible RCF of tubes used should be verified with the individual manufacturers.
The max. RCF for glass tubes annotated with footnote 2) is 4,000.
97
ROTINA 380 | 380 R | BENCHTOP CENTRIFUGES
Rotor
max. RPM
max. RCF
ROTINA 380 | 380 R 10,000 min | 11,000 min
-1
13,640 | 16,504
-1 + lid bioseal 5)
Cat. No. INCLUSIVE
Vessels
capacity in ml 1.5 2.0 15 25 50 94 7.5 – 8.5 9 – 10 10 8.5 – 10 5 15 50 10 30
Ø x L in mm 11 x 38 11 x 38 17 x 100 24 x 100 34 x 100 38 x 102 15 x 92 16 x 92 15 x 102 16 x 100 17 x 59 17 x 120 29 x 115 16 x 80 26 x 95
max. RCF 2) ROTINA 380 13,081 13,081 12,857 12,522 13,416 13,640 12,857 12,857 12,857 12,857 12,745 13,081 13,304 12,857 12,522
max. RCF 2) ROTINA 380 R 15,828 15,828 15,557 15,151 16,233 16,504 15,557 15,557 15,557 15,557 15,422 15,828 16,098 15,557 15,151
radius in mm 117 117 115 112 120 122 115 115 115 115 114 117 119 115 112
Cat. No. microliter tubes tubes 2) blood collection tubes / urine tubes - tubes with screw cap
+
Adapter
boring Ø x L in mm 11.4 x 39 11.4 x 39 17.5 x 92 26 x 85 35 x 89 38.2 x 89.6 17.5 x 92 17.5 x 92 17.5 x 92 17.5 x 92 17 x 51 17 x 106 29.8 x 97 16.5 x 74 26 x 85
vessels per rotor 24 24 6 6 6 6 6 6 6 6 6 6 6 12 6
Cat. No. 1449 1449 1451 1447 1463 - 1451 1451 1451 1451 1476 1466 1454 1448 1447
Vessels
capacity in ml 50 85
Ø x L in mm 29 x 107 38 x 106
max. RCF 2) ROTINA 380 13,081 13,640
max. RCF 2) ROTINA 380 R 15,828 16,504
radius in mm 117 122
Cat. No. tubes with screw
+
cap
Adapter
boring Ø x L in mm 29 x 92 38.2 x 89.6
vessels per rotor 6 6
Cat. No. 1446 -
1) For cooled versions: Lowest temperature achievable with precooling and max. speed.
2) Please note that the RCF values indicated refer only to rotor performance. The max. permissible RCF of tubes used should be verified with the individual manufacturers.
The max. RCF for glass tubes annotated with footnote 2) is 4,000.
5) Tested by TÜV in conformity with DIN EN 61010, section 2 - 020.
98
ANGLE ROTOR, 30-PLACE | 1789-A
+
Lid bioseal5),
Rotor phenol-resistant
Vessels
capacity in ml 0.2 0.4 0.5 0.8 1.5 2 0.5
Ø x L in mm 6 x 18 6 x 45 8 x 30 8 x 45 11 x 38 11 x 38 10.7 x 36
max. RCF 2) 24,400 24,400 24,400 24,400 24,400 24,400 23,394
radius in mm 97 97 97 97 97 97 93 1) For cooled versions: Lowest temperature achievable with
Cat. No. microliter tubes Pediatric precooling and max. speed.
+
2) Please note that the RCF values indicated refer only to rotor
performance. The max. permissible RCF of tubes used
should be verified with the individual manufacturers.
The max. RCF for glass tubes annotated with footnote 2) is
4,000.
Adapter
5) Tested by the TÜV in conformity with DIN EN 61010, section
boring Ø x L in mm 6 x 40 6 x 40 8 x 40 8 x 40 10.2 x 19.3 11.2 x 40.9 11.2 x 40.9 2 - 020.
vessels per rotor 30 30 30 30 30 30 15 7) For centrifugation at high speeds, we recommend to use
form-fitting, phenol-resistant adapters. Cat. No. 2031.
Cat. No. 2024 2024 2023 2023 20317) - 078817) 17) Packaging unit 15 pieces.
PACKAGES
ROTINA 380 BLOOD TUBE PACKAGE 1 number of vessels volume (ml) size (mm) RPM RCF
- 1 x ROTINA 380 centrifuge 1701 64 1.6 - 7 13 x 75 / 100 5,000 4,668
- 1 x swing-out rotor, 4-place 1754 52 4 - 10 16 x 75 / 100 5,000 4,668
- 4 x bucket 1752
- 4 x lid (bioseal) 1751
- 4 x adapter, 16-place 1783-A
- 4 x adapter, 13-place 1763-A
1701SET1
ROTINA 380 CONICAL PACKAGE 2 number of vessels volume (ml) size (mm) RPM RCF
- 1 x ROTINA 380 centrifuge 1701 64 1.6 - 7 13 x 75 / 100 5,000 4,668
- 1 x swing-out rotor, 4-place 1754 52 4 - 10 16 x 75 / 100 5,000 4,668
- 4 x bucket 1752
- 4 x adapter, 9-place (conical) 1771-A
- 4 x adapter, 4-place (conical) 1772-A
1701SET2
ROTINA 380 R CONICAL PACKAGE 1 number of vessels volume (ml) size (mm) RPM RCF
- 1 x ROTINA 380 R centrifuge 1706 64 1.6 - 7 13 x 75 / 100 5,000 4,668
- 1 x swing-out rotor, 4-place 1754 52 4 - 10 16 x 75 / 100 5,000 4,668
- 4 x bucket 1752
- 4 x adapter, 9-place (conical) 1771-A
- 4 x adapter, 4-place (conical) 1772-A
1706SET1
99
ROTINA 420 | 420 R
Many solutions – one rotor
This compact benchtop centrifuge has been developed for large sample volumes. It has a maximum capacity of 4 x 600 ml
bottles, 140 blood tubes, 16 microtiter plates or 52 x 15 ml conical tubes, all on a single cost-effective rotor. This unit is
available with refrigeration and a temperature range from -20 °C to +40 °C (ROTINA 420 R).
100
TECHNICAL DATA
ROTINA 420 ROTINA 420 R
non-refrigerated refrigerated
voltage *) 200 – 240 V 1 ~ 200 – 240 V 1 ~
frequency 50 – 60 Hz 50 Hz
AVAILABLE ROTORS
SWING-OUT ROTORS angle max. RPM max. capacity Cat. No. page
ANGLE ROTORS
101
ROTINA 420 | 420 R | BENCHTOP CENTRIFUGES
Bucket
Rotor with clamp lock
max. RPM | max. RCF
max. capacity
run-up | run-down, braked in sec
4,800 min-1 | 4,740
4 x 600 ml
54 | 38
+ lid bioseal 5)
Cat. No.
4783
4780
Vessels
capacity in ml 1.5 2.0 3 4 4 5 6 7 15 25 50 94 100 100 250
Ø x L in mm 11 x 38 11 x 38 10 x 60 10 x 88 12 x 60 12 x 75 12 x 82 12 x 100 17 x 100 24 x 100 34 x 100 38 x 102 40 x 115 44 x 100 65 x 115
max. RCF 2) 4,585 4,585 4,585 4,585 4,585 4,585 4,585 4,585 4,585 4,585 4,559 4,559 4,559 4,534 4,534
radius in mm 178 178 178 178 178 178 178 178 178 178 177 177 177 176 176
Cat. No. microliter tubes tubes 2)
+
Adapter
boring Ø x L in mm 11.2 x 38 11.2 x 38 11.2 x 54 11.2 x 54 13.4 x 55 13.4 x 55 13.4 x 55 13.4 x 55 17.5 x 62 26.5 x 69 36 x 77 42 x 76.5 42 x 76.5 46 x 76.5 66 x 97
vessels per rotor 96 96 140 140 104 104 104 104 72 28 16 12 12 8 4
Cat. No. 4773 4773 4761 4761 4762 4762 4762 4762 4763 4764 4765 4766 4766 4767 4768
3.6)
Vessels
capacity in ml 1.1–1.4 2.6–3.4 2.7–3 4–5.5 4.5–5 4.9 7.5–8.5 9–10 1.6–7 1.6–7 4–7 8 8.5 – 10 5 15
Ø x L in mm 8 x 66 13 x 65 11 x 66 15 x 75 11 x 92 13 x 90 15 x 92 16 x 92 13 x 75 13 x 100 16 x 75 16 x 125 16 x 100 17 x 59 17 x 120
max. RCF 2) 4,585 4,585 4,585 4,585 4,585 4,585 4,585 4,585 4,585 4,585 4,585 4,585 4,585 4,740 4,740
radius in mm 178 178 178 178 178 178 178 178 178 178 178 178 178 184 184
Cat. No. blood collection / urine vessels - -
+
29) 29) 21)
Adapter
boring Ø x L in mm 11.2 x 54 13.4 x 55 11.2 x 54 17.5 x 62 11.2 x 54 13.4 x 55 17.5 x 62 17.5 x 62 13.7 x 55 13.7 x 55 17.5 x 62 17.5 x 62 17.5 x 62 17 x 52 17 x 84
vessels per rotor 140 104 140 72 140 104 72 72 84 84 72 24 72 48 52
Cat. No. 4761 4762 4761 4763 4761 4762 4763 4763 4775 4775 4763 4763 4763 4778 4769
1) Lowest attainable temperature in precooled refrigerated centrifuges at max. speed. Lower temperatures can be attained by reducing the speed.
2) Please note that the RCF values indicated refer only to rotor performance. The max. permissible RCF of tubes used should be verified with the individual manufacturers.
The max. RCF for glass tubes annotated with footnote 2) is 4,000.
3.6) When using these tubes, bucket 4780 cannot be closed with lid 4783.
5) Tested by the TÜV in conformity with DIN EN 61010, section 2 - 020.
14) With the E3905 add-on kit and the 4783 lid, the 4785 carrier can be converted at a later time to a 4780 carrier with single-hand clamp lock.
21) Adapter must be loaded as illustrated.
29) Suitable for blood collection systems with a lid larger than 17 mm in diameter.
102
SWING-OUT ROTOR, 4-PLACE | 4784-A
Bucket
Rotor with clamp lock
3.6)
Vessels
capacity in ml 50 12 25 30 50 10 30 50 85 94 175 175 200 225 250
Ø x L in mm 29 x 115 17 x 100 25 x 90 25 x 110 29 x 115 16 x 80 26 x 95 29 x 107 38 x 106 38 x 102 61 x 118 62 x 144 60 x 130 61 x 137 61 x 122
max. RCF 2) 4,688 4,688 4,585 4,585 4,688 4,585 4,585 4,688 4,534 4,534 4,740 4,740 4,740 4,740 4,740
radius in mm 182 182 178 178 182 178 178 182 176 176 184 184 184 184 184
Cat. No. tubes with screw cap Falcon Nalgene Nunc® Falcon 5127 24)
+
21)
Adapter
boring Ø x L in mm 30 x 82.5 17.2 x 82.5 26.5 x 69 26.5 x 69 30 x 82.5 17.5 x 62 26.5 x 69 30 x 82.5 42 x 76.5 42 x 76.5 61 x 105 61.5 x 110 61.5 x 110 61 x 105 62 x 100
vessels per rotor 20 56 28 28 20 72 28 20 12 12 4 4 4 4 4
Cat. No. 4770 4774 4764 4764 4770 4) 4763 4764 4770 4) 4766 4766 4776 4777 4777 4776 4771
Vessels
capacity in ml 290 400 400 600
Ø x L in mm 62 x 137 81 x 136 84 x 134 93 x 134
max. RCF 2) 4,740 4,740 4,740 4,740
radius in mm 184 184 184 184
Cat. No. - 24) - 24) - 24) 0551 24)
+
Adapter
boring Ø x L in mm 62 x 100 85 x 100 85 x 100 94 x 99
vessels per rotor 4 4 4 4
Cat. No. 4771 4772 4772 -
1) Lowest attainable temperature in precooled refrigerated centrifuges at max. speed. Lower temperatures can be attained by reducing the speed.
2) Please note that the RCF values indicated refer only to rotor performance. The max. permissible RCF of tubes used should be verified with the individual manufacturers.
The max. RCF for glass tubes annotated with footnote 2) is 4,000.
3.6) When using these tubes, carrier 4780 cannot be closed with lid 4783.
4) Please remove the spacer.
5) Tested by the TÜV in conformity with DIN EN 61010, section 2 - 020.
13) The screw cap for tube No. 0538 is available with Cat. No. 0539. Dimensions with cap 38 x 110 mm.
21) Adapter must be loaded as illustrated.
24) At temperatures of over +40 °C and / or when not filled to capacity, bottles may warp during centrifugation.
103
ROTINA 420 | 420 R | BENCHTOP CENTRIFUGES
+
Rotor Bucket
max. RPM | max. RCF 4,000 min-1 | 2,898 lid 5053
max. capacity 4 x 100 ml Cat. No. 5051
run-up | run-down, braked in sec 18 | 16
angle | max. noise level 90° | 58 dB (A)
temperature in °C 1) -1
Cat. No. 4753
Vessels
capacity in ml 1.5 2 1.5 2 3 5 6 7 9 15 25 50 100 100
Ø x L in mm 11 x 38 11 x 38 11 x 38 11 x 38 10 x 60 12 x 75 12 x 82 12 x 100 14 x 100 17 x 100 24 x 100 34 x 100 44 x 100 40 x 115
max. RCF 2) top / bottom 1,950 / 1,950 / 2,826 2,826 2,737 2,773 2,773 2,755 2,773 2,755 2,755 2,755 2,755 2,755
2,826 2,826
radius in mm top / bottom 109 / 158 109 / 158 158 158 153 155 155 154 155 154 154 154 154 154
Cat. No. microliter tubes tubes 2)
+
Adapter
boring Ø x L in mm 12.5 x 42 12.5 x 42 11.5 x 50 11.5 x 50 11 x 44 12.5 x 42 12.5 x 42 12.5 x 86 16 x 50 17.5 x 86 26 x 86 36 x 86 45.5 x 86 42 x 86
vessels per rotor 160 160 64 64 80 80 80 80 48 48 20 8 4 4
Cat. No. 5257 5257 5281 5281 5267 5227 5227 5247 15) 5264 5248 15) 5242 5243 5262 5249
3.7)
Vessels
capacity in ml 1.1 – 1.4 2.6 – 3.4 2.7 – 3 4 – 5.5 4.5 – 5 4.9 7.5 – 8.5 9 – 10 10 1.6 – 5 4 – 7 4 – 7 8.5 – 10
Ø x L in mm 8 x 66 13 x 65 11 x 66 15 x 75 11 x 92 13 x 90 15 x 92 16 x 92 15 x 102 13 x 75 13 x 100 16 x 75 16 x 100
max. RCF 2) 2,737 2,808 2,773 2,773 2,773 2,808 2,773 2,755 2,755 2,808 2,755 2,773 2,755
radius in mm 153 157 155 155 155 157 155 154 154 157 154 155 154
Cat. No. blood collection / urine vessels
+
Adapter
boring Ø x L in mm 11 x 44 13.5 x 52 12.5 x 42 16 x 50 12.5 x 42 13.5 x 52 16 x 50 17.6 x 86 17.6 x 86 13.5 x 52 13.5 x 86 16 x 50 17.5 x 86
vessels per rotor 80 48 80 48 80 48 48 44 44 48 48 48 48
Cat. No. 5267 5268 5227 5264 5227 5268 5264 5258 5258 5268 6301 5264 5248
+
+ 2 x 6316
1) Lowest attainable temperature in precooled refrigerated
centrifuges at max. speed. Lower temperatures can be
attained by reducing the speed.
2) Please note that the RCF values indicated refer only to
rotor performance. The max. permissible RCF of tubes
Adapter
used should be verified with the individual manufacturers.
boring Ø x L in mm 17 x 90 26 x 66 30 x 86 17 x 90 36 x 86 - The max. RCF for glass tubes annotated with footnote 2)
vessels per rotor 28 20 8 28 8 8 is 4,000.
3.7) When using these tubes, bucket 4780 or 5051 cannot
Cat. No. 6306 5266 5259 6306 5243 5280 be closed with lid 4783 or 5053.
104
SWING-OUT ROTOR, 4-PLACE | 4753
+
Rotor Bucket
Vessels
capacity in ml 5 6 7 15 25 50 100 100 250 1.1–1.4 2.6–3.4 2.7–3 4–5.5 4.5–5 4.9
Ø x L in mm 12 x 75 12 x 82 12 x 100 17 x 100 24 x 100 34 x 100 44 x 100 40 x 115 65 x 115 8 x 66 13 x 65 11 x 66 15 x 75 11 x 92 13 x 90
max. RCF 2) 3,005 3,005 3,005 2,952 2,898 2,952 2,952 2,952 3,095 2,540 2,540 2,540 2,952 3,005 2,952
radius in mm 168 168 168 165 162 165 165 165 173 142 142 142 165 168 165
Cat. No. tubes 2) blood collection / urine vessels
+
Adapter
boring Ø x L in mm 12.8 x 45 12.8 x 45 13.2x82 17.5 x 60.7 25.5 x 82 35.5 x 82,5 45.5 x 85 42 x 85 66 x 103 13.2x54.5 13.2x54.5 13.2x54.5 17.5 x 60.7 13.2x82 13.5 x 60.7
vessels per rotor 48 48 48 32 16 4 4 4 4 48 48 48 32 48 32
Cat. No. 5128 5128 5120 5136 5122 5124 5125 5126 1791 5138 5138 5138 5136 5120 5137
3.5)
Vessels
capacity in ml 7.5–8.5 9 – 10 10 1.6 – 5 4–7 4–7 8.5 – 10 8 15 50 12 25 30 50 10
Ø x L in mm 15 x 92 16 x 92 15 x 102 13 x 75 13 x 100 16 x 75 16 x 100 16 x 125 17 x 120 29 x 115 17 x 100 25 x 90 25 x 110 29 x 115 16 x 80
max. RCF 2) 2,952 2,952 2,952 2,540 3,005 2,952 2,952 3,059 3,095 3,095 3,005 2,826 2,898 3,023 2,952
radius in mm 165 165 165 142 168 165 165 171 173 173 168 158 162 169 165
Cat. No. blood collection / urine vessels tubes with screw cap
+
Adapter
boring Ø x L in mm 17.5 x 60.7 17.5 x 60.7 17.5 x 60.7 13.2x54.5 13.2 x82 17.5 x 60.7 17.5 x 60.7 17.5 x 82 17 x 85 30 x 85 17.5 x 82 26 x 73 25.5 x 82 30 x 99 17.5 x 60.7
vessels per rotor 32 32 32 48 48 32 32 28 28 8 28 12 16 8 32
Cat. No. 5136 5136 5136 5138 5120 5136 5136 51214) 5129 5123 5121 5134 5122 5135 5136
3.5)
Vessels
capacity in ml 250 290
Ø x L in mm 61 x 122 62 x 137
1) Lowest attainable temperature in precooled refrigerated
max. RCF 2) 3,095 3,095
centrifuges at max. speed. Lower temperatures can be
radius in mm 173 173 attained by reducing the speed.
Cat. No. 5127 24) - 24) 2) Please note that the RCF values indicated refer only to
+
rotor performance. The max. permissible RCF of tubes
used should be verified with the individual manufacturers.
The max. RCF for glass tubes annotated with footnote 2)
is 4,000.
3.5) When using these tubes, bucket 5092 cannot be closed
Adapter
with lid 5053.
boring Ø x L in mm 66 x 103 66 x 103 5) Tested by the TÜV in conformity with DIN EN 61010,
vessels per rotor 4 4 section 2 - 020.
24) At temperatures of over +40 °C and / or when not filled
Cat. No. 6319 6319 to capacity, bottles may warp during centrifugation.
105
ROTINA 420 | 420 R | BENCHTOP CENTRIFUGES
Rotor Bucket
+
max. RPM | max. RCF 4,800 min-1 | 4,096 Cat. No. 4782
max. capacity 16 plates
run-up | run-down, braked in sec 54 | 38
angle | max. noise level 90° | 56 dB (A)
temperature in °C 1) +4
Cat. No. 4784-A
Plates
W x D x H in mm 128 x 86 x 15 128 x 86 x 17.5 128 x 86 x 22 128 x 86 x 44.5 128 x 86 x 46 84 x 59 x 11 124 x 82 x 20 -
capacity in ml - - - - - - - 0,2
max. RCF 2) 4,096 4,096 4,096 4,096 4,096 4,096 4,096 4,096
radius in mm 159 159 159 159 159 159 159 159
Cat. No. MTP MTP CP DWP MS Microtest PCR plate PCR strips
+
plate 96 wells
Adapter
boring Ø x L in mm - - - - - - - -
plates / strips per rotor 16 16 12 4 4 8 4 48 x 8
Cat. No. - - - - - - 1485 1485
Rotor
max. RPM | max. RCF 9,500 min-1 | 12,007
max. capacity 4 x 250 ml
run-up | run-down, braked in sec 45 | 55
angle 25°
temperature in °C 1) +2
Cat. No. 4795
Vessels
capacity in ml 15 25 94 15 50 10 30 50 85 94 250
Ø x L in mm 17 x 100 24 x 100 38 x 102 17 x 120 29 x 115 16 x 80 26 x 95 29 x 107 38 x 106 38 x 102 61 x 122 1) For cooled versions: Lowest
temperature achievable with
max. RCF 2) 11,301 10,897 10,292 10,998 10,090 11,402 10,897 10,090 10,292 10,292 12,007 precooling and max. speed.
radius in mm 112 108 102 109 100 113 108 100 102 102 119 2) Please note that the RCF values
Cat. No. tubes 2) tubes with screw cap 5127 24) indicated refer only to rotor
+
performance. The max. permis-
sible RCF of tubes used should
be verified with the individual
manufacturers. The max. RCF
for glass tubes annotated with
Adapter
footnote 2) is 4,000.
boring Ø x L in mm 17.6 x 83 26 x 80 38.6 x 88 17 x 106 30 x 100 16.6 x 70 26 x 80 29 x 90 38.6 x 88 38.6 x 88 61.5 x 109 24) At temperatures of over +40 °C
vessels per rotor 28 12 4 20 4 32 12 4 4 4 4 and / or when not filled to ca-
pacity, bottles may warp during
Cat. No. 5646 5642 5644 5637 5638 5641 5642 5643 5644 5644 - centrifugation.
106
ANGLE ROTOR, 6-PLACE | 4794
Vessels
capacity in ml 1.5 – 2 3 15 25 50 94 7.5 – 10 5 15 50 10 30 50 85 94
Ø x L in mm 11 x 38 10 x 60 17 x 100 24 x 100 34 x 100 38 x 102 15x102 /
16x92 36) 17 x 59 17 x 120 29 x 115 16 x 80 26 x 95 29 x 107 38 x 106 38 x 102
max. RCF 2) 15,828 15,828 15,557 15,151 16,233 16,504 15,557 15,422 15,828 16,098 15,557 15,151 15,828 16,504 16,504
radius in mm 117 117 115 112 120 122 115 114 117 119 115 112 117 122 122
Cat. No. - tubes 2) - - tubes with screw cap
+
Adapter
boring Ø x L in mm 11.4 x 39 11.4 x 39 17.5 x 92 26 x 85 35 x 89 38.2 x 89.6 17.5 x 92 17 x 51 17 x 106 29.8 x 97 16.5 x 74 26 x 85 29 x 92 38.2 x 89.6 38.2 x 89.6
vessels per rotor 24 24 6 6 6 6 6 6 6 6 12 6 6 6 6
Cat. No. 1449 1449 1451 1447 1463 - 1451 1476 1466 1454 1448 1447 1446 - -
1) For cooled versions: Lowest temperature achievable with precooling and max. speed.
2) Please note that the RCF values indicated refer only to rotor performance. The max. permissible RCF of tubes used should be verified with the individual manufacturers. The max. RCF for
glass tubes annotated with footnote 2) is 4,000.
5) Tested by the TÜV in conformity with DIN EN 61010, section 2 - 020.
36) Capacity in ml: 8.5-10 Ø x L in mm: 16 x 100.
107
ROTINA 420 | 420 R | BENCHTOP CENTRIFUGES
+
Lid bioseal 5),
Rotor phenol-resistant
max. RPM | max. RCF 15,000 min-1 | 24,400 Cat. No. INCLUSIVE
max. capacity 30 x 2 ml
run-up | run-down, braked in sec 19 | 24
angle | max. noise level 45° | 50 dB (A)
temperature in °C 1) +4
Cat. No. 4790-A
Vessels
capacity in ml 0.2 0.4 0.5 0.8 1.5 2 0.5
Ø x L in mm 6 x 18 6 x 45 8 x 30 8 x 45 11 x 38 11 x 38 10.7 x 36
max. RCF 2) 24,400 24,400 24,400 24,400 24,400 24,400 23,394
radius in mm 97 97 97 97 97 97 93
Cat. No. microliter tubes Pediatric
+
Adapter
boring Ø x L in mm 6 x 40 6 x 40 8 x 40 8 x 40 10.2 x 19.3 11.2 x 40.9 11.2 x 40.9
vessels per rotor 30 30 30 30 30 30 15
Cat. No. 2024 2024 2023 2023 20317) - 0788 17)
1) For cooled versions: Lowest temperature achievable with precooling and max. speed.
2) Please note that the RCF values indicated refer only to rotor performance. The max. permissible RCF of tubes used should be verified with the individual manufacturers. The max. RCF for
glass tubes annotated with footnote 2) is 4,000.
5) Tested by the TÜV in conformity with DIN EN 61010, section 2 - 020.
7) For centrifugation at high speeds, we recommend to use form-fitting, phenol-resistant adapters. Cat. No. 2031.
17) Packaging unit 15 pieces.
108
PACKAGES
ROTINA 420 RCF
BLOOD TUBE PACKAGE 1 number of vessels volume (ml) size (mm) RPM
- 1 x ROTINA 420 centrifuge 4701 64 1.6 - 7 13 x 75 / 100 4,800 4,585
- 1 x swing-out rotor, 4-place 4784-A 52 4 - 10 16 x 75 / 100 4,800 4,585
- 4 x bucket 4780
- 4 x lid (bioseal) 4783
- 4 x adapter, 26-place 4762
- 4 x adapter, 18-place 4763
4701SET1
ROTINA 420 CONICAL PACKAGE 2 number of vessels volume (ml) size (mm) RPM RCF
- 1 x ROTINA 380 centrifuge 4701 64 1.6 - 7 13 x 75 / 100 5,000 4,668
- 1 x swing-out rotor, 4-place 4784-A 52 4 - 10 16 x 75 / 100 5,000 4,668
- 4 x bucket 4785
- 4 x adapter, 13-place (conical) 4769
- 4 x adapter, 5-place (conical) 4770
4701SET2
ROTINA 420 R CONICAL PACKAGE 2 number of vessels volume (ml) size (mm) RPM RCF
- 1 x ROTINA 420 R centrifuge 4706 64 1.6 - 7 13 x 75 / 100 5,000 4,668
- 1 x swing-out rotor, 4-place 4784-A 52 4 - 10 16 x 75 / 100 5,000 4,668
- 4 x bucket 4785
- 4 x adapter, 13-place (conical) 4769
- 4 x adapter, 5-place (conical) 4770
4706SET2
109
ROTANTA 460 | 460 R
Superior benchtop for multi-purpose use
This powerful unit is capable of virtually any application you choose. It is able to spin high sample volumes of blood tubes,
conical tubes, plates and bottles. Speciality buckets are able to accommodate 450 ml blood bags. This unit is available with
refrigeration and a temperature range from -20 °C to +40 °C (ROTANTA 460 R).
110
TECHNICAL DATA
ROTANTA 460 ROTANTA 460 R
non-refrigerated refrigerated
voltage *) 220 – 240 V 1 ~ 220 – 240 V 1 ~
frequency 50 – 60 Hz 50 Hz
AVAILABLE ROTORS
SWING-OUT ROTORS angle max. RPM max. capacity Cat. No. page
5,900 min-1 /
swing-out rotor, 2-place 90° 12 plates 5622 123
6,200 min-1
ANGLE ROTORS
8,500 min-1/
angle rotor, 6-place 25° 6 x 250 ml 5645 124
9,500 min-1
111
ROTANTA 460 | 460 R | BENCHTOP CENTRIFUGES
Rotor
max. RPM | max. RCF 2)
max. capacity
4,600 min-1 | 5,063
4 x 250 ml
+ Bucket
lid bioseal 5)
Cat. No.
5627
5625-A
run-up | run-down, braked in sec 90 | 95
angle | temperature in °C 1) 90° | +10
Cat. No. 5699-R
Vessels
capacity in ml 1.5 2.0 3 4 4 5 6 7 15 25 50 94 100 100 250
Ø x L in mm 11 x 38 11 x 38 10 x 60 10 x 88 12 x 60 12 x 75 12 x 82 12 x 100 17 x 100 24 x 100 34 x 100 38 x 102 44 x 100 40 x 115 65 x 100
max. RCF 2) 3,572 4,637 4,637 4,637 4,637 4,637 4,637 4,637 4,637 4,637 4,495 4,495 4,637 4,495 4,495
radius in mm 151 196 196 196 196 196 196 196 196 196 190 190 196 190 190
Cat. No. microliter tubes tubes 2)
+
Adapter
boring Ø x L in mm 11 x 84 11 x 84 11 x 84 11 x 84 13.5 x 84 13.5 x 84 13.5 x 84 13.5 x 84 17.5 x 84 26.5 x 84 36 x 80 42 x 80 46 x 84 42 x 80 66 x 80
vessels per rotor 224 224 120 120 80 80 80 80 68 24 12 12 8 12 4
Cat. No. 4730 4730 4730 4730 4732 4732 4732 4732 4733 4734 4735 4736 4737 4736 4738
Vessels
capacity in ml 1.1–1.4 2.6–3.4 2.7–3 4–5.5 4.5–5 4.9 7.5–8.5 9–10 10 1.6–5 4–7 4–7 8.5 – 10 14 15
Ø x L in mm 8 x 66 13 x 65 11 x 66 15 x 75 11 x 92 13 x 90 15 x 92 16 x 92 15 x 102 13 x 75 13 x 100 16 x 75 16 x 100 16.5 x 106 17 x 120
max. RCF 2) 4,637 4,637 4,637 4,637 4,637 4,637 4,637 4,637 4,637 4,637 4,637 4,637 4,637 4,637 4,637
radius in mm 196 196 196 196 196 196 196 196 196 196 196 196 196 196 196
Cat. No. blood collection / urine vessels tubes with
+
screw cap
Adapter
boring Ø x L in mm 11 x 84 13.5 x 84 13.5 x 84 17.5 x 84 13.5 x 84 13.5 x 84 17.5 x 84 17.5 x 84 17.5 x 84 13.5 x 84 13.5 x 84 17.5 x 84 17.5 x 84 17 x 80 17 x 80
vessels per rotor 120 80 80 68 80 80 68 68 68 80 80 68 68 48 48
Cat. No. 4730 4732 4732 4733 4732 4732 4733 4733 4733 4732 4732 4733 4733 4739 4) 4739
Vessels
capacity in ml 50 12 25 30 50 10 30 50 85 94
Ø x L in mm 29 x 115 17 x 100 25 x 90 25 x 110 29 x 115 16 x 80 26 x 95 29 x 107 38 x 106 38 x 102
max. RCF 2) 4,637 4,637 4,637 4,637 4,637 4,637 4,637 4,637 4,637 4,495 1) For cooled versions: Lowest tempe-
radius in mm 196 196 196 196 196 196 196 196 196 190 rature achievable with precooling and
Cat. No. tubes with screw cap max. speed.
+
2) Please note that the RCF values indica-
ted refer only to rotor performance. The
max. permissible RCF of tubes used
should be verified with the individual
manufacturers. The max. RCF for glass
Adapter
tubes annotated with footnote 2) is
boring Ø x L in mm 30 x 80 17 x 80 26.5 x 84 26.5 x 84 30 x 80 17.5 x 84 26.5 x 84 30 x 80 42 x 80 42 x 80 4,000.
vessels per rotor 20 48 24 24 20 68 24 20 12 12 4) Please remove the spacer.
5) Tested by the TÜV in conformity with
Cat. No. 4740 4739 4) 4734 4734 4740 4733 4734 4740 4736 4736 DIN EN 61010, section 2 - 020.
112
SWING-OUT ROTOR, 4-PLACE | 5699-R
Bucket with
+
Rotor clamp lock
Vessels
capacity in ml 1.5 2.0 3 4 4 5 6 7 15 25 45 50 94 100 100
Ø x L in mm 11 x 38 11 x 38 10 x 60 10 x 88 12 x 60 12 x 75 12 x 82 12 x 100 17 x 100 24 x 100 31 x 100 34 x 100 38 x 102 40 x 115 44 x 100
max. RCF 2) 3,572 4,637 4,637 4,637 4,637 4,637 4,637 4,637 4,637 4,637 4,495 4,495 4,495 4,495 4,637
radius in mm 151 196 196 196 196 196 196 196 196 196 190 190 190 190 196
Cat. No. microliter tubes tubes 2)
+
Adapter
boring Ø x L in mm 11 x 84 11 x 84 11 x 84 11 x 84 13.5 x 84 13.5 x 84 13.5 x 84 13.5 x 84 17.5 x 84 26.5 x 84 36 x 80 36 x 80 42 x 80 42 x 80 46 x 84
vessels per rotor 192 192 96 96 76 76 76 76 76 28 16 16 12 12 8
Cat. No. 4830 4830 4830 4830 4832 4832 4832 4832 4833 4834 4835 4835 4836 4836 4837
Vessels
capacity in ml 250 1.1–1.4 2.6–3.4 2.6–3.4 2.7–3 4–5.5 4.5–5 4.9 4.9 7.5–8.5 9 – 10 9 – 10 10 1.6 – 5 1.6 – 5
Ø x L in mm 65 x 100 8 x 66 13 x 65 13 x 65 11 x 66 15 x 75 11 x 92 13 x 90 13 x 90 15 x 92 16 x 92 16 x 92 13 x 90 13 x 75 13 x 75
max. RCF 2) 4,495 4,637 4,116 4,637 4,637 4,637 4,637 4,637 4,684 4,637 4,684 4,637 4,637 4,116 4,637
radius in mm 190 196 174 196 196 196 196 196 198 196 198 196 196 174 196
Cat. No. - 2) blood collection / urine vessels
+
Adapter
boring Ø x L in mm 66 x 80 11 x 84 13.2 x 61 13.5 x 84 13.5 x 84 17.5 x 84 13.5 x 84 13.5 x 84 13.2 x 61 17.5 x 84 17.5 x 61 17.5 x 84 17.5 x 84 13.2 x 61 13.5 x 84
vessels per rotor 4 96 108 76 76 76 76 76 108 76 88 76 76 108 76
Cat. No. 4838 4830 4847 4832 4832 4833 4832 4832 4847 4) 4833 4848 4833 4833 4847 4832
Vessels
capacity in ml 4–7 4–7 4–7 4–7 8 8.5 – 10 8.5 – 10 5 14 15 50 50 12 25 30
Ø x L in mm 13 x 100 13 x 100 16 x 75 16 x 75 16 x 125 16 x 100 16 x 100 17 x 59 16.5 x 106 17 x 120 29 x 115 29 x 115 17 x 100 25 x 90 25 x 110
max. RCF 2) 4,684 4,637 4,637 4,684 4,637 4,637 4,684 4,637 4,637 4,637 4,708 4,637 4,637 4,566 4,566
radius in mm 198 196 196 198 196 196 198 196 196 196 199 196 196 193 193
Cat. No. blood collection / urine vessels - tubes with screw cap
+
Adapter
boring Ø x L in mm 13.2 x 61 13.5 x 84 17.5 x 84 17.5 x 61 17.5 x 84 17.5 x 84 17.5 x 61 17 x 80 17 x 80 17 x 80 30 x 96.5 30 x 80 17 x 80 26.5 x 84 26.5 x 84
vessels per rotor 108 76 76 88 76 76 88 56 56 56 28 20 56 28 28
Cat. No. 4847 4) 4832 4833 4848 4833 4833 4848 4839 4839 4) 4839 5647 4840 4839 4) 4834 4834
113
ROTANTA 460 | 460 R | BENCHTOP CENTRIFUGES
Bucket with
+
Rotor clamp lock
max. RPM | max. RCF 4,600 min-1 | 4,779 lid bioseal 5)
4883
max. capacity 4 x 750 ml Cat. No. 4880
run-up | run-down, braked in sec 90 | 95
angle 90°
Bucket without
temperature in °C 1) +7 clamp lock 14)
Cat. No. 5699-R Cat. No. 4885
3.8)
Vessels
capacity in ml 50 50 10 10 30 50 50 85 94 250 290 500 600 650 750
Ø x L in mm 29 x 115 29 x 115 16 x 80 16 x 80 26 x 95 29 x 107 29 x 107 38 x 106 38 x 102 61 x 122 62 x 137 96 x 147 93 x 134 97 x 139 97 x 152
max. RCF 2) 4,708 4,637 4,637 4,684 4,637 4,637 4,708 4,495 4,495 4,779 4,779 4,779 4,779 4,779 4,779
radius in mm 199 196 196 198 196 196 199 190 190 202 202 202 202 202 202
Cat. No. tubes with screw cap 5127 24) - 24) Corning® 0551 24) 0554 24) 0512 24)
+
Adapter
4845 +
support
cushion
431124
Adapter Fa. Corning
boring Ø x L in mm 30 x 96.5 30 x 80 17.5 x 84 17.5 x 61 26.5 x 84 30 x 80 30 x 96.5 42 x 80 42 x 80 62 x 100 62 x 100 98 x 100 94 x 95 98 x 100 98 x 100
vessels per rotor 28 20 76 88 28 20 28 12 12 4 4 4 4 4 4
Cat. No. 5647 4) 4840 4) 4833 4848 4834 4840 4) 5647 4) 4836 4836 4841 4841 4845 4846 4845 4845
Vessels
capacity in ml 450 750 30 50 40 160 200 200 200
Ø x L in mm 97 x 110 93 x 135 - - - - - - -
max. RCF 2) 4,779 4,779 4,613 27) 4,613 27) 4,613 27) 4,613 27) 4,613 27) 4,613 27) 4,613 27)
radius in mm 202 202 195 195 195 195 195 195 195
Cat. No. 4447 4234-A Falcon® Corning® Nunc® Nunc® Falcon® Greiner® Nunc®
+
Adapter
boring Ø x L in mm 98 x 100 98 x 100 - - - - - - -
vessels per rotor 4 4 8 8 4 8 4 4 4
Cat. No. 4845 4845 4849 4849 4852 4851 4831 4831 4831
1) For cooled versions: Lowest temperature achievable with precooling and max. speed.
2) Please note that the RCF values indicated refer only to rotor performance. The max. permissible RCF of tubes used should be verified with the individual manufacturers.
The max. RCF for glass tubes annotated with footnote 2) is 4,000.
3.8) When using these tubes, bucket 4880 cannot be closed with lid 4883.
3.9) When using these tubes, bucket 4890 cannot be closed with lid 4883.
4) Please remove the spacer.
5) Tested by the TÜV in conformity with DIN EN 61010, section 2 - 020.
14) With the E3905 add-on kit and the 4783 lid, the 4785 carrier can be converted at a later time to a 4780 carrier with single-hand clamp lock.
21) Adapter must be loaded as illustrated.
24) At temperatures of over +40 °C and / or when not filled to capacity, bottles may warp during centrifugation.
27) RCF values indicated refer only to rotor performance. The max. RCF for the accommodated cell culture flasks is 2,300.
28) We recommend the use of the refrigerated ROTANTA 460 R, 460 RC, or 460 RF to ensure that the temperature of the blood is maintained during centrifugation.
114
SWING-OUT ROTOR, 4-PLACE | 5699-R
Bucket with
Rotor clamp lock
Vessels
capacity in ml 1.5 2.0 5 7 8 9 15 25 50 100 2.6–3.4 2.7–3 4–5.5 4.5–5 4.9
Ø x L in mm 11 x 38 11 x 38 12 x 75 12 x 100 16 x 81 14 x 100 17 x 100 24 x 100 34 x 100 44 x 100 13 x 65 11 x 66 15 x 75 11 x 92 13 x 90
max. RCF 2) top / bottom 3,407 3,407 4,471 4,471 4,637 4,637 4,637 4,353 4,424 4,400 4,471 4,471 4,637 4,471 4,471
/ 4,542 / 4,542
radius in mm
top / bottom 144 144 189 189 196 196 196 184 187 186 189 189 196 189 189
/ 192 / 192
Cat. No. microliter tubes tubes 2) blood collection / urine vessels
+
+ 0726
Adapter
boring Ø x L in mm 11.5 x 38 11.5 x 38 13 x 58 13 x 58 17.5 x 53 17.5 x 53 17.5 x 53 26 x 72 36 x 79 45 x 78 13.5 x 58 13 x 58 17.5 x 53 13 x 58 13.5 x 58
vessels per rotor 168 168 120 120 76 76 76 28 16 8 84 120 76 120 84
Cat. No. 4432 4432 4433 4433 4434 4434 4434 4438 4439 4442 4435 4433 4434 4433 4435
Vessels
capacity in ml 7.5–8.5 9 – 10 10 1.6 – 5 4–7 4–7 8 8.5 – 10 10 15 50 25 30 50 50
Ø x L in mm 15 x 92 16 x 92 15 x 102 13 x 75 13 x 100 16 x 75 16 x 125 16 x 100 16 x 80 17 x 120 29 x 115 25 x 90 25 x 110 29 x 115 29 x 107
max. RCF 2) 4,637 4,637 4,637 4,471 4,471 4,637 4,637 4,637 4,637 4,755 4,613 4,566 4,566 4,613 4,613
radius in mm 196 196 196 189 189 196 196 196 196 201 195 193 193 195 195
Cat. No. blood collection / urine vessels tubes with screw cap
+
Adapter
boring Ø x L in mm 17.5 x 53 17.5 x 53 17.5 x 53 13.5 x 58 13.5 x 58 17.5 x 53 17.5 x 53 17.5 x 53 17.5 x 53 17 x 93.1 31 x 96 26 x 72 26 x 72 31 x 96 31 x 96
vessels per rotor 76 76 76 84 84 76 76 76 76 56 28 28 28 28 28
Cat. No. 4434 4434 4434 4435 4435 4434 4434 4434 4434 4469 4468 4438 4438 4468 4) 4468
3.9) 3.9)
Vessels
capacity in ml 250 290 650 750 175 175 200 225 250 500 450 750 450
Ø x L in mm 61 x 122 62 x 137 97 x 139 97 x 152 61 x 118 62 x 144 60 x 130 61 x 137 60 x 162 96 x 147 97 x 110 93 x 135 3-place-system without filter
max. RCF 2) 4,873 4,873 4,873 4,873 5,063 5,063 5,063 5,063 5,063 5,063 5,063 5,063 5,063
radius in mm 206 206 206 206 214 214 214 214 214 214 214 214 214
Cat. No. 5127 24) - 24) 0554 24) 0512 24) Falcon® Nalgene® Nunc® Falcon® Corning® Corning® 4447 4234-A blood bags 28)
+
Adapter
boring Ø x L in mm 62 x 92 62 x 92 98.4 x 116 98.4 x 116 - - - - - - 98.4 x 116 98.4 x 116 -
vessels per rotor 4 4 4 4 4 4 4 4 4 4 4 4 4
Cat. No. 4443 4443 4451 4451 4440 4430 4430 4440 4430 4449 4451 4451 -
115
ROTANTA 460 | 460 R | BENCHTOP CENTRIFUGES
Rotor
max. RPM | max. RCF 2)
max. capacity
4,600 min-1 | 4,637
4 x 450 ml
+ Bucket
Cat. No. 5691-A
Blood bags
capacity in ml 450 450
blood bag 3-place-System 4-place-System
max. RCF 2) 4,637 4,637
radius in mm 196 196
Cat. No. 5693 5695
+
Insert
boring Ø x L in mm - -
blood bags per rotor 4 4
Cat. No. 5692 5692
Rotor
max. RPM | max. RCF 2)
max. capacity
4,600 min-1 | 4,921
12 Arrays
+ Bucket
Cat. No. 5636
TaqMan Array
Array
capacity in ml -
W x D x H in mm 152.5 x 85.5 x 12
max. RCF 2) 4.921
radius in mm 208
Cat. No. -
+
Adapter
boring Ø x L in mm - 1) For cooled versions: Lowest temperature achievable with precooling and max. speed.
arrays per rotor 12 2) Please note that the RCF values indicated refer only to rotor performance. The max. permissible RCF of
tubes used should be verified with the individual manufacturers.
Cat. No. 5648 The max. RCF for glass tubes annotated with footnote 2) is 4,000.
116
SWING-OUT ROTOR, 4-PLACE | 5699-R
Rotor
+ Bucket
Vessels
capacity in ml 1.5 2.0 3 5 6 7 9 25 50 100 100 250 1.1–1.4 2.6–3.4 2.7 – 3
Ø x L in mm 11 x 38 11 x 38 10 x 60 12 x 75 12 x 82 12 x 100 14 x 100 24 x 100 34 x 100 44 x 100 44 x 115 65 x 115 8 x 66 13 x 65 11 x 66
max. RCF 2) 4,164 4,164 4,069 4,164 4,164 4,164 4,116 4,093 4,093 4,069 4,069 4,045 4,069 4,164 4,116
radius in mm 176 176 172 176 176 176 174 173 173 172 172 171 172 176 174
Cat. No. microliter tubes tubes 2) blood collection /
+
urine vessels
+ 5220-A + 5220-A + 5220-A + 5220-A + 5220-A + 5220-A + 5220-A + 5220-A + 5220-A + 5220-A + 5220-A + 5220-A + 5220-A + 5220-A + 5220-A
Adapter
boring Ø x L in mm 11.5 x 50 11.5 x 50 11 x 44 13.5 x 52 13.5 x 52 13.5 x 52 16 x 50 26 x 86 36 x 86 45.5 x 86 42 x 86 66 x 87 11 x 44 13.5 x 52 12.5 x 42
vessels per rotor 128 128 160 96 96 96 96 40 16 8 8 4 160 96 160
Cat. No. 19) 5281 5281 5267 5268 5268 5268 5264 5242 5243 5262 5249 5263-A 5267 5268 5227
Vessels
capacity in ml 4–5.5 4.5–5 4.9 7.5–8.5 9 – 10 1.6 – 5 4–7 4–7 8.5 – 10 15 30 50 50 250
Ø x L in mm 15 x 75 11 x 92 13 x 90 15 x 92 16 x 92 13 x 75 16 x 75 13 x 100 16 x 100 17 x 120 25 x 110 29 x 115 29 x 115 61 x 122
max. RCF 2) 4,116 4,116 4,164 4,116 4,093 4,164 4,116 4,164 4,093 4,258 4,187 4,258 4,187 3,196
radius in mm 174 174 176 174 173 176 174 176 173 180 177 180 177 177
Cat. No. blood collection / urine vessels tubes with screw cap 5127 24)
+
+ 5220-A + 5220-A + 5220-A + 5220-A + 5220-A + 5220-A + 5220-A + 5220-A + 5220-A + 5220-A + 6319
Adapter
boring Ø x L in mm 16 x 50 12.5 x 42 13.5 x 52 16 x 50 17.6 x 86 13.5 x 52 16 x 50 13.5 x 52 17.7 x 86 17 x 90 26 x 86 30 x 90 30 x 87 66 x 87
vessels per rotor 96 160 96 96 88 96 96 96 88 56 40 24 24 4
Cat. No. 19) 5264 5227 5268 5264 5258 5268 5264 5268 5258 6337-B 5266 4) 6338-B 6339-A 5263-A4)
+
Adapter
1)
2)
For cooled versions: Lowest temperature achievable with precooling and max. speed.
Please note that the RCF values indicated refer only to rotor performance. The max. permissible RCF of
tubes used should be verified with the individual manufacturers.
The max. RCF for glass tubes annotated with footnote 2) is 4,000.
4) Please remove the spacer.
boring Ø x L in mm - 9) Max. permissible loading weight of carrier 5628: 800 g. The loading weight is the sum of the weight of the
vessels per rotor 16 respective adapters, frames, the tubes and their contents.
19) Two adapters can be placed on each bucket.
Cat. No. 19) 5280 24) At temperatures of over +40 °C and / or when not filled to capacity, bottles may warp during centrifugation.
117
ROTANTA 460 | 460 R | BENCHTOP CENTRIFUGES
Rotor
max. RPM | max. RCF
max. capacity
4,600 min-1 | 3,785
4 x 200 ml
+ Bucket
Cat. No. 5630-B
40 ml
Vessels Nunc®, No. 156340 or 156367
capacity in ml 40 160 200 200 200
160 ml
Ø x L in mm - - - - -
Nunc®, No. 156472 or 156499
max. RCF 2) 3,785 27) 3,785 27) 3,785 27) 3,785 27) 3,785 27) Sarstedt®, No. 83.3911.xxx
radius in mm 160 160 160 160 160
Cat. No. Nunc® Nunc® Falcon® Greiner® Nunc® 200ml
+
Becton Dickinson®, No. 353024
Greiner®, No. 658170
Nunc®, No. 153732 or 147589
Adapter
boring Ø x L in mm - - - - -
vessels per rotor 4 4 4 4 4
Cat. No. 5672 5673 5671 5671 5671
Rotor
max. RPM | max. RCF
max. capacity
4,600 min-1 | 3,832
20 plates
+ Bucket
Cat. No. 5630-B
Plates
W x D x H in mm 128 x 86 x 15 128 x 86 x 17.5 128 x 86 x 22 128 x 86 x 44.5 128 x 86 x 46 128 x 86 x 83 84 x 59 x 11 124 x 82 x 20 -
capacity in ml - - - - - - - - 0.2
max. RCF 2) 3,832 3,832 3,832 3,832 3,832 3,832 3,832 3,832 3,832
radius in mm max. 162 max. 162 max. 162 max. 162 max. 162 max. 162 max. 162 max. 162 max. 162
Cat. No. MTP MTP CP DWP MS QP Microtest PCR plate PCR strips
+
plate
Removal frame
boring Ø x L in mm - - - - - - - - -
plates / strips per rotor 20 16 12 4 4 4 8 4 48 x 8
Cat. No. 4626 4626 4626 4626 4626 4626 4626 4626 + 1485 4626 + 1485
1) For cooled versions: Lowest temperature achievable with precooling and max. speed.
2) Please note that the RCF values indicated refer only to rotor performance. The max. permissible RCF of tubes used should be verified with the individual manufacturers.
The max. RCF for glass tubes annotated with footnote 2) is 4,000.
27) RCF values indicated refer only to rotor performance. The max. RCF for the accommodated cell culture flasks is 2,300.
118
SWING-OUT ROTOR, 4-PLACE | 5699-R
Rotor
+ Bucket
Plates
W x D x H in mm 128 x 86 x 15 128 x 86 x 17.5 128 x 86 x 22 128 x 86 x 44.5 128 x 86 x 46 128 x 86 x 83 84 x 59 x 11 124 x 82 x 20 -
capacity in ml - - - - - - - - 0.2
max. RCF 2) 4,211 4,211 4,211 4,211 4,211 4,211 4,211 4,211 4,211
radius in mm max. 178 max. 178 max. 178 max. 178 max. 178 max. 178 max. 178 max. 178 max. 178
Cat. No. MTP MTP CP DWP MS QP Microtest PCR plate PCR strips
+
plate
Removal frame
boring Ø x L in mm - - - - - - - - -
plates / strips per rotor 24 20 16 4 4 4 8 4 48 x 8
Cat. No. 4626 4626 4626 4626 4626 4626 4626 4626 + 1485 4626 + 1485
+
Rotor Bucket
max. RPM | max. RCF 3,800 min-1 | 2,890 lid bioseal 5) 5629
max. capacity 24 plates Cat. No. 5653
run-up | run-down, braked in sec 61 | 57
angle | max. noise level 90° | 57 dB (A)
temperature in °C 1) -4
Cat. No. 5654
Plates
W x D x H in mm 128 x 86 x 15 128 x 86 x 17.5 128 x 86 x 22 128 x 86 x 44.5 128 x 86 x 46 128 x 86 x 83 84 x59 x 11 124 x 82 x 20 -
capacity in ml - - - - - - - - 0.2
max. RCF 2) 2,890 2,890 2,890 2,890 2,890 2,890 2,890 2,890 2,890
radius in mm max. 179 max. 179 max. 179 max. 179 max. 179 max. 179 max. 179 max. 179 max. 179
Cat. No. MTP MTP CP DWP MS QP Microtest PCR plate PCR strips
+
plate
Removal frame
boring Ø x L in mm - - - - - - - - -
plates / strips per rotor 24 20 16 4 4 4 8 4 48 x 8
Cat. No. 4626 4626 4626 4626 4626 4626 4626 4626 + 1485 4626 + 1485
1) For cooled versions: Lowest temperature achievable with precooling and max. speed.
2) Please note that the RCF values indicated refer only to rotor performance. The max. permissible RCF of tubes used should be verified with the individual manufacturers.
The max. RCF for glass tubes annotated with footnote 2) is 4,000.
5) Tested by TÜV in conformity with DIN EN 61010, section 2 - 020.
27) RCF values indicated refer only to rotor performance. The max. RCF for the accommodated cell culture flasks is 2,300.
119
ROTANTA 460 | 460 R | BENCHTOP CENTRIFUGES
+
Rotor Bucket
max. RPM | max. RCF 3,800 min-1 | 3,196 lid bioseal 5) 5652
max. capacity 4 x 1,000 ml Cat. No. 5651-A
run-up | run-down, braked in sec 61 | 57
angle | max. noise level 90° | 58 dB (A)
temperature in °C 1) +3
Cat. No. 5654
3.10)
Vessels
capacity in ml 3 4 4 5 6 7 10 10 15 1.1–1.4 2.6–3.4 2.7–3 4.5–5 4–5.5 4.9
Ø x L in mm 10 x 60 10 x 88 12 x 60 12 x 75 12 x 82 12 x 100 13 x 100 13 x 100 17 x 100 8 x 66 13 x 65 11 x 66 11 x 92 15 x 75 13 x 90
max. RCF 2) 2,874 2,874 2,874 2,874 2,874 2,874 2,906 2,906 2,970 2,874 2,906 2,874 2,874 2,970 2,906
radius in mm 178 178 178 178 178 178 180 180 184 178 180 178 178 184 180
Cat. No. tubes 2) blood collection / urine vessels
+
Adapter
boring Ø x L in mm 12.5 x 40 12.5 x 40 12.5 x 40 12.5 x 40 12.5 x 40 12.5 x 40 13.2 x 42.4 13.2 x 42.4 17.2 x 46.5 12.5 x 40 13.2 x 42.4 12.5 x 40 12.5 x 40 17.2 x 46.5 13.2 x 42.4
vessels per rotor 292 292 292 292 292 292 196 188 148 292 196 292 292 148 196
Cat. No. 5684 5684 5684 5684 5684 5684 5674 5685 5682 5684 5674 5684 5684 5682 5674
3.10)
Vessels
capacity in ml 7.5–8.5 9 – 10 10 1.6 – 5 4–7 4–7 4–7 8.5 – 10 10 5 15 50 175 175 200
Ø x L in mm 15 x 92 16 x 92 15 x 102 13 x 75 16 x 75 13 x 100 13 x 100 16 x 100 16 x 80 17 x 59 17 x 120 29 x 115 61 x 118 62 x 144 60 x 130
max. RCF 2) 2,970 2,970 2,970 2,906 2,970 2,906 2,906 2,970 2,970 3,196 3,196 3,196 3,196 3,196 3,196
radius in mm 184 184 184 180 184 180 180 184 184 198 198 198 198 198 198
Cat. No. blood collection / urine vessels - tubes with Falcon® Nalgene® Nunc®
+
screw cap
+ 5677 + 5676 + 5676
Adapter
boring Ø x L in mm 17.2 x 46.5 17.2 x 46.5 17.2 x 46.5 13.2 x 42.4 17.2 x 46.5 13.2 x 42.4 13.2 x 42.4 17.2 x 46.5 17.2 x 46.5 17 x 42 17 x 60 30 x 60 62 x 100 62 x 100 62 x 100
vessels per rotor 148 148 148 196 148 196 188 148 148 80 96 40 8 8 8
Cat. No. 5682 5682 5682 5674 5682 5674 5685 5682 5682 5688 5683 5686 5681 5681 5681
3.10)
+ 4449 3.10) 3.10)
Vessels
capacity in ml 225 250 290 450 500 600 650 750 1,000
Ø x L in mm 61 x 137 61 x 122 62 x 137 97 x 110 96 x 147 93 x 134 97 x 139 97 x 152 99/126x140 1) For cooled versions: Lowest temperature
achievable with precooling and max. speed.
max. RCF 2) 3,196 3,196 3,196 3,196 3,196 3,196 3,196 3,196 3,196
2) Please note that the RCF values indicated
radius in mm 198 198 198 198 198 198 198 198 198 refer only to rotor performance. The max. per-
Cat. No. Falcon® 5127 24) - 24) 4447 Corning® 0551 24) 0554 24) 0512 24) - missible RCF of tubes used should be verified
+
with the individual manufacturers. The max.
+ 5677
RCF for glass tubes annotated with footnote
2) is 4,000.
3.10) When using this tubes, bucket 5651-A cannot
be closed with lid 5652.
Adapter
5) Tested by TÜV in conformity with DIN EN
boring Ø x L in mm 62 x 100 62 x 100 62 x 100 98 x 100 98 x 100 98 x 100 98 x 100 98 x 100 100/127x68 61010, section 2 - 020.
vessels per rotor 8 8 8 4 4 4 4 4 4 24) At temperatures of over +40 °C and / or when
not filled to capacity, bottles may warp during
Cat. No. 5681 5681 5681 5687 5687 5687 5687 5687 5669 centrifugation.
120
SWING-OUT ROTOR, 6-PLACE | 4446
+
Rotor Bucket
Vessels
capacity in ml 1.5 2 1.5 2 3 5 6 7 9 15 25 50 100 100
Ø x L in mm 11 x 38 11 x 38 11 x 38 11 x 38 10 x 60 12 x 75 12 x 82 12 x 100 14 x 100 17 x 100 24 x 100 34 x 100 44 x 100 40 x 115
max. RCF 2) top / bottom 2,486 2,486 3,363 3,363 3,274 3,309 3,309 3,291 3,309 3,291 3,291 3,291 3,291 3,291
/ 3,363 / 3,363
radius in mm top / bottom 139 / 188 139 / 188 188 188 183 185 185 184 185 184 184 184 184 184
Cat. No. microliter tubes tubes 2)
+
Adapter
boring Ø x L in mm 12.5 x 42 12.5 x 42 11.5 x 50 11.5 x 50 11 x 44 12.5 x 42 12.5 x 42 12.5 x 86 16 x 50 17.5 x 86 26 x 86 36 x 86 45.5 x 86 42 x 86
vessels per rotor 240 240 96 96 120 120 120 120 72 72 30 12 6 6
Cat. No. 5257 5257 5281 5281 5267 5227 5227 5247 15) 5264 5248 15) 5242 5243 5262 5249
3.11)
Vessels
capacity in ml 1.1 – 1.4 2.6 – 3.4 2.7 – 3 4 – 5.5 4.5 – 5 4.9 7.5 – 8.5 9 – 10 10 1.6 – 5 4 – 7 4 – 7 8.5 – 10
Ø x L in mm 8 x 66 13 x 65 11 x 66 15 x 75 11 x 92 13 x 90 15 x 92 16 x 92 15 x 102 13 x 75 13 x 100 16 x 75 16 x 100
max. RCF 2) 3,274 3,345 3,309 3,309 3,309 3,345 3,309 3,291 3,291 3,345 3,345 3,309 3,291
radius in mm 183 187 185 185 185 187 185 184 184 187 187 185 184
Cat. No. blood collection / urine vessels
+
Adapter
boring Ø x L in mm 11 x 44 13.5 x 52 12.5 x 42 16 x 50 12.5 x 42 13.5 x 52 16 x 50 17.6 x 86 17.6 x 86 13.5 x 52 13.5 x 52 16 x 50 17.5 x 86
vessels per rotor 120 72 120 72 120 72 72 66 66 72 72 72 72
Cat. No. 5267 5268 5227 5264 5227 5268 5264 5258 5258 5268 5268 5264 5248
+
2) Please note that the RCF values indicated refer
+2x6316
only to rotor performance. The max. permissib-
le RCF of tubes used should be verified with the
individual manufacturers.
The max. RCF for glass tubes annotated with
Adapter
footnote 2) is 4,000.
boring Ø x L in mm 17 x 90 26 x 86 30 x 86 17 x 90 26 x 86 36 x 86 - 3.11) When using these tubes, bucket 5051 cannot
vessels per rotor 42 30 12 42 30 12 12 be closed with lid 5053.
15) With Cat. No. 5247-91 or 5248-91 these adap-
Cat. No. 6306 5266 5259 6306 5266 5243 5280 ters can also be ordered with a decanting aid.
121
ROTANTA 460 | 460 R | BENCHTOP CENTRIFUGES
Rotor
max. RPM | max. RCF
max. capacity
4,000 min-1 | 3,631
6 x 290 ml
+ Bucket
lid bioseal 5)
Cat. No.
5093
5092
run-up | run-down, braked in sec 45 | 55
angle | temperature in °C 1) 90° | -3
Cat. No. 4446
Vessels
capacity in ml 5 6 7 15 25 50 100 100 250 1.1–1.4 1.1–1.4 2.6–3.4 2.6–3.4 2.7–3 2.7 – 3
Ø x L in mm 12 x 75 12 x 82 12 x 100 17 x 100 24 x 100 34 x 100 44 x 100 40 x 115 65 x 115 8 x 66 8 x 66 13 x 65 13 x 65 11 x 66 11 x 66
max. RCF 2) 3,542 3,542 3,542 3,488 3,434 3,488 3,488 3,488 3,631 3,488 3,077 3,488 3,077 3,488 3,077
radius in mm 198 198 198 195 192 195 195 195 203 195 172 195 172 195 172
Cat. No. tubes 2) blood collection tubes / urine tubes
+
Adapter
boring Ø x L in mm 12.8 x 45 12.8 x 45 13.2x82 17.5 x 60.7 25.5 x 82 35.5 x 82.5 45.5 x 85 42 x 85 66 x 103 13.5 x 60.7 13.2x54.5 13.5 x 60.7 13.2x54.5 13.5 x 60.7 13.2x54.5
vessels per rotor 72 72 72 48 24 6 6 6 6 48 72 48 72 48 72
Cat. No. 5128 5128 5120 5136 5122 5124 5125 5126 1791 5137 5138 5137 5138 5137 5138
3.5)
Vessels
capacity in ml 4.9 4–5.5 4.5–5 7.5–8.5 9 – 10 10 1.6 – 5 1.6 – 5 4–7 4–7 8 8.5 – 10 10 15 30
Ø x L in mm 13 x 90 15 x 75 11 x 92 15 x 92 16 x 92 15 x 102 13 x 75 13 x 75 16 x 75 13 x 100 16 x 125 16 x 100 16 x 80 17 x 120 25 x 110
max. RCF 2) 3,488 3,488 3,542 3,488 3,488 3,488 3,488 3,077 3,488 3,542 3,542 3,488 3,488 3,631 3,434
radius in mm 195 195 198 195 195 195 195 172 195 198 198 195 195 203 192
Cat. No. blood collection tubes / urine tubes tubes with screw cap
+
Adapter
boring Ø x L in mm 13.5 x 60.7 17.5 x 60.7 13.2x82 17.5 x 60.7 17.5 x 60.7 17.5 x 60.7 13.5 x 60.7 13.2x54.5 12.8 x 60.7 13.2x82 17.5 x 82 17.5 x 60.7 17.5 x 60.7 17 x 85 25.5 x 82
vessels per rotor 48 48 72 48 48 48 48 72 48 72 42 48 48 42 24
Cat. No. 5137 5136 5120 5136 5136 5136 5137 5138 5136 5120 5121 5136 5136 5129 5122
3.5)
Vessels
capacity in ml 50 50 12 25 30 250 290
Ø x L in mm 29 x 115 29 x 115 17 x 100 25 x 90 25 x 110 61 x 122 62 x 137 1) For cooled versions: Lowest temperature
achievable with precooling and max. speed.
max. RCF 2) 3,631 3,560 3,542 3,363 3,434 3,631 3,631 2) Please note that the RCF values indicated
radius in mm 203 199 198 188 192 203 203 refer only to rotor performance.
Cat. No. tubes with screw cap 5127 24) - 24) The max. permissibleRCF of tubes used
+
should be verified with the individual ma-
nufacturers. The max. RCF for glass tubes
annotated with footnote 2) is 4,000.
3.5) When using these tubes, bucket 5092 can-
not be closed with lid 5053.
Adapter
5) Tested by the TÜV in conformity with DIN EN
boring Ø x L in mm 30 x 85 30 x 99 17.5 x 82 26 x 73 25.5 x 82 66 x 103 66 x 103 61010, section 2 - 020.
vessels per rotor 12 12 42 18 24 6 6 24) At temperatures of over +40 °C and / or when
not filled to capacity, bottles may warp during
Cat. No. 5123 5135 5121 5134 5122 6319 6319 centrifugation.
122
SWING-OUT ROTOR, 2-PLACE | 5622
+
Rotor Bucket
Plates
W x D x H in mm 128 x 86 x 15 128 x 86 x 17.5 128 x 86 x 22 128 x 86 x 44.5 128 x 86 x 46 128 x 86 x 83 84 x 59 x 11 124 x 82 x 20 -
capacity in ml - - - - - - - - 0.2
max. RCF 2) ROTANTA 460 | 460 R 5,838 | 6,446 5,838 | 6,446 5,838 | 6,446 5,838 | 6,446 5,838 | 6,446 5,838 | 6,446 5,838 | 6,446 5,838 | 6,446 5,838 | 6,446
radius in mm 150 150 150 150 150 150 150 150 150
Cat. No. MTP MTP CP DWP MS QP Microtest PCR plate PCR strips
+
plate 96 wells
Removal frame
boring Ø x L in mm - - - - - - - - -
vessels per rotor 12 10 8 2 2 2 4 2 24 x 8
Cat. No. 4626 4626 4626 4626 4626 4626 4626 4626 + 1485 4626 + 1485
+
Rotor Bucket
max. RPM | max. RCF 2,000 min-1 | 984 Cat. No. 4275
max. capacity 4 x 100 ml
run-up | run-down, braked in sec 17 | 20
angle | max. noise level 90° | 46 dB (A)
temperature in °C 1) -8
Cat. No. 4474
Vessels
capacity in ml 50 100 100 100 50
Ø x L in mm 45 x 130 58 x 161 44 x 168 37 x 200 36.5 x 185
max. RCF 2) 984 984 961 961 912
radius in mm 220 220 215 215 204
Cat. No. ASTM 2.1) ASTM 0528 2.1)
ASTM 2.1) ASTM 0531 2.1) Babcock 1) For cooled versions: Lowest tempe-
+
rature achievable with precooling and
max. speed.
2.1) Please note that the RCF values indica-
ted refer only to rotor performance. The
max. permissible RCF of vessels used
Adapter
should be verified with the individual
boring Ø x L in mm - - - - - manufacturers.The max. RCF for ASTM
vessels per rotor 4 4 4 4 4 Tubes annotated with footnote 2) is 700.
5) Tested by the TÜV in conformity with
Cat. No. 4278-A 0771 4277 4276-B 0703-A DIN EN 61010, section 2 - 020.
123
ROTANTA 460 | 460 R | BENCHTOP CENTRIFUGES
+
Lid bioseal 5)
Rotor and phenol-resistant
max. RPM | max. RCF 15,000 min-1 | 24,400 Cat. No. INCLUSIVE
max. capacity 30 x 2 ml
run-up | run-down, braked in sec 73 | 77
angle | temperature in °C 1) 45° | +4
Cat. No. 4489-A
Vessels
capacity in ml 0.2 0.4 0.5 0.8 1.5 2 0.5
Ø x L in mm 6 x 18 6 x 45 8 x 30 8 x 45 11 x 38 11 x 38 10.7 x 36
max. RCF 2) 24,400 24,400 24,400 24,400 24,400 24,400 23,394
radius in mm 97 97 97 97 97 97 93
Cat. No. microliter tubes Pediatric
+
Adapter
boring Ø x L in mm 6 x 40 6 x 40 8 x 40 8 x 40 10.2 x 19.3 11.2 x 40.1 11.2 x 40.1
vessels per rotor 30 30 30 30 30 30 15
Cat. No. 2024 2024 2023 2023 20317) - 0788
Rotor
max. RPM ROTANTA 460 | 460 R
max. RCF
8,500 min-1 | 9,500 min-1
11,228 | 14,025
+ Lid bioseal 5)
Cat. No. INCLUSIVE
Vessels
capacity in ml 15 25 94 15 50 10 30 50 85 94 250
Ø x L in mm 17 x 100 24 x 100 38 x 102 17 x 120 29 x 115 16 x 80 26 x 95 29 x 107 38 x 106 38 x 102 61 x 122
max. RCF 2) ROTANTA 460 10,662 10,339 9,855 10,339 9,693 10,743 10,339 9,693 9,855 9,855 11,228
max. RCF 2) ROTANTA 460 R 13,319 12,915 12,310 12,915 12,108 13,420 12,915 12,108 12,310 12,310 14,025
radius in mm 132 128 122 128 120 133 128 120 122 122 139
Cat. No. tubes 2) tubes with screw cap 5127 24)
+
Adapter
boring Ø x L in mm 17.6 x 83 26 x 80 38.6 x 88 17 x 106 30 x 100 16.6 x 70 26 x 80 29 x 90 38.6 x 88 38.6 x 88 61.5 x 109
vessels per rotor 42 18 6 30 6 48 18 6 6 6 6
Cat. No. 5646 5642 5644 5637 5638 5641 5642 5643 5644 5644 -
124
ANGLE ROTOR, 6-PLACE | 5615
Rotor
+ Lid bioseal 5)
Vessels
capacity in ml 0.5 1.5 2.0 3 15 25 50 94 7.5 – 8.5 9 – 10 10 8.5 – 10 5 15 50
Ø x L in mm 10.7 x 36 11 x 38 11 x 38 10 x 60 17 x 100 24 x 100 34 x 100 38 x 102 15 x 92 16 x 92 15 x 102 16 x 100 17 x 59 17 x 120 29 x 115
max. RCF 2) 17,299 17,299 17,299 17,299 17,003 16,560 17,743 18,038 17,003 17,003 17,003 17,003 16,856 17,299 17,595
radius in mm 117 117 117 117 115 112 120 122 115 115 115 115 114 117 119
Cat. No. Pediatric microliter tubes tubes 2) blood collection / urine tubes - tubes with
screw cap
+
Adapter
boring Ø x L in mm 11.4 x 39 11.4 x 39 11.4 x 39 11.4 x 39 17.5 x 92 26 x 85 35 x 89 38.2 x 89.6 17.5 x 92 17.5 x 92 17.5 x 92 17.5 x 92 17 x 51 17 x 106 29.8 x 97
vessels per rotor 24 24 24 24 6 6 6 6 6 6 6 6 6 6 6
Cat. No. 1449 1449 1449 1449 1451 1447 1463 - 1451 1451 1451 1451 1476 1466 1454
Vessels
capacity in ml 10 30 50 85 94
Ø x L in mm 16 x 80 26 x 95 29 x 107 38 x 106 38 x 102
max. RCF 2) 17,003 16,560 17,299 18,038 18,038
radius in mm 115 112 117 122 122
Cat. No. tubes with screw cap 1) For cooled versions: Lowest temperature achievable with precooling and max.
+
speed.
2) Please note that the RCF values indicated refer only to rotor performance. The
max. permissibleRCF of tubes used should be verified with the individual manu-
facturers.
Adapter The max. RCF for glass tubes annotated with footnote 2) is 4,000.
5) Tested by the TÜV in conformity with DIN EN 61010, section 2 - 020.
boring Ø x L in mm 16.5 x 74 26 x 85 29 x 92 38.2 x 89.6 38.2 x 89.6 7) For centrifugation at high speeds, we recommend to use form-fitting, phe-
vessels per rotor 12 6 6 6 6 nol-resistant adapters. Cat. No. 2031.
24) At temperatures of over +40 °C and / or when not filled to capacity, bottles
Cat. No. 1448 1447 1446 - - may warp during centrifugation.
125
ROTANTA 460 | 460 R | BENCHTOP CENTRIFUGES
5650SET1
ROTANTA 460 CONICAL PACKAGE 2 number of vessels volume (ml) size (mm) RPM RCF
- 1 x ROTANTA 460 centrifuge 5650 56 15 17 x 120 4,600 4,637
- 1 x swing-out rotor, 4-place 5699-R 28 50 29 x 115 4,600 4,708
- 4 x bucket 4885
- 4 x adapter, 14-place (conical) 4839
- 4 x adapter, 7-place (conical) 5647
5650SET2
ROTANTA 460 R CONICAL PACKAGE 1 number of vessels volume (ml) size (mm) RPM RCF
- 1 x ROTANTA 460 R centrifuge 5660 56 15 17 x 120 4,600 4,755
- 1 x swing-out rotor, 4-place 5699-R 28 50 29 x 115 4,600 4,613
- 4 x bucket 4890
- 4 x lid (bioseal) 4883
- 4 x adapter, 7-place (conical) 4468
- 4 x adapter, 14-place (conical) 4469
5660SET1
ROTANTA 460 R CONICAL PACKAGE 2 number of vessels volume (ml) size (mm) RPM RCF
- 1 x ROTANTA 460 R centrifuge 5660 56 15 17 x 120 4,600 4,637
- 1 x swing-out rotor, 4-place 5654 28 50 29 x 115 4,600 4,708
- 4 x bucket 5651-A
- 4 x adapter, 24-place (conical) 5683
- 4 x adapter, 10-place (conical) 5686
5660SET2
ROTANTA 460 R CONICAL PACKAGE 3 number of vessels volume (ml) size (mm) RPM RCF
- 1 x ROTANTA 460 R centrifuge 5660 56 15 17 x 120 4,600 4,637
- 1 x swing-out rotor, 4-place 5699-R 28 50 29 x 115 4,600 4,708
- 4 x bucket 4885
- 4 x adapter, 14-place (conical) 4839
- 4 x adapter, 7-place (conical) 5647
5660SET3
ROTANTA 460 R BLOOD TUBES PACKAGE 4 number of vessels volume (ml) size (mm) RPM RCF
- 1 x ROTANTA 460 R centrifuge 5660 188 4-10 13 x 100 3,800 2,906
- 1 x swing-out rotor, 4-place 5654 148 4.5-15 17 x 100 3,800 2,970
- 4 x bucket 5651-A
- 4 x lid (bioseal) 5652
- 4 x adapter, 47-place 5685
- 4 x adapter, 37-place 5682
5660SET4
ROTANTA 460 R BLOOD TUBES PACKAGE 5 number of vessels volume (ml) size (mm) RPM RCF
- 1 x ROTANTA 460 R centrifuge 5660 108 2.6 -7 13 x 100 4,600 4,684
- 1 x swing-out rotor, 4-place 5699-R 88 4 - 10 16 x 100 4,600 4,684
- 4 x bucket 4880
- 4 x lid (bioseal) 4883
- 4 x adapter, 27-place 4847
- 4 x adapter, 22-place 4848
5660SET5
126
PACKAGES ROTANTA 460 RF
ROTANTA 460 RF CONICAL PACKAGE 1 number of vessels volume (ml) size (mm) RPM RCF
- 1 x ROTANTA 460 RF centrifuge 5675 56 15 17 x 120 4,600 4,637
- 1 x swing-out rotor, 4-place 5654 28 50 29 x 115 4,600 4,708
- 4 x bucket 5651-A
- 4 x adapter, 24-place (conical) 5683
- 4 x adapter, 10-place (conical) 5686
5675SET1
ROTANTA 460 RF CONICAL PACKAGE 2 number of vessels volume (ml) size (mm) RPM RCF
- 1 x ROTANTA 460 RF centrifuge 5675 56 15 17 x 120 4,600 4,637
- 1 x swing-out rotor, 4-place 5699-R 28 50 29 x 115 4,600 4,708
- 4 x bucket 4885
- 4 x adapter, 14-place (conical) 4839
- 4 x adapter, 7-place (conical) 5647
5675SET2
ROTANTA 460 RF BLOOD TUBE PACKAGE 3 number of vessels volume (ml) size (mm) RPM RCF
- 1 x ROTANTA 460 RF centrifuge 5675 188 4-10 13 x 100 3,800 2,906
- 1 x swing-out rotor, 4-place 5654 148 4.5-15 17 x 100 3,800 2,970
- 4 x bucket 5651-A
- 4 x lid (bioseal) 5652
- 4 x adapter, 47-place 5685
- 4 x adapter, 37-place 5682
5675SET3
ROTANTA 460 RF BLOOD TUBE PACKAGE 4 number of vessels volume (ml) size (mm) RPM RCF
- 1 x ROTANTA 460 RF centrifuge 5675 108 2.6 -7 13 x 100 4,600 4,684
- 1 x swing-out rotor, 4-place 5699-R 88 4 - 10 16 x 100 4,600 4,684
- 4 x bucket 4880
- 4 x lid (bioseal) 4883
- 4 x adapter, 27-place 4847
- 4 x adapter, 22-place 4848
5675SET4
127
ROTOFIX 46 | 46 H
Robust industrial unit
These are ideal centrifuges for research and industrial laboratories. They are robust and can withstand intensive usage, in the
field. Specialty buckets are able to hold ASTM pear-shaped and conical tubes for petroleum testing. Heated option provides
chamber temperature up to +90 °C (ROTOFIX 46 H).
128
TECHNICAL DATA
ROTOFIX 46 ROTOFIX 46 H
non-refrigerated heated
voltage *) 200 – 240 V 1 ~ 200 – 240 V 1 ~
frequency 50 – 60 Hz 50 – 60 Hz
ROTOFIX 46 | 46 H
consumption 460 VA 600 VA
emission, immunity EN / IEC 61326-1, class B EN / IEC 61326-1, class B
max. capacity 4 x 290 ml 4 x 100 ml
max. RPM 4,000 min-1 2,000 min-1
max. RCF 3,095 984
running time 1 – 99 min : 59 sec, continuous run, 1 – 99 min : 59 sec, continuous run,
short cycle mode (impulse button) short cycle mode (impulse button)
dimesions (W x D x H) 538 x 647 x 345 mm 538 x 647 x 345 mm
weight approx. 60 kg approx. 60 kg
noise level 50 dB (A) with rotor 4619 38 dB (A) with rotor 4619
temperature setting, infinitely variable
- from +10 to +90 °C
(dependent on the ambient temperature)
Cat. No. 4600 4600-50
AVAILABLE ROTORS
SWING-OUT ROTORS angle max. RPM max. capacity Cat. No. page
ANGLE ROTOR
129
ROTOFIX 46 | 46 H | BENCHTOP CENTRIFUGES
Rotor
max. RPM | max. RCF 2,000 min-1 | 805
max. capactiy 6 x 50 ml
run-up | run-down, braked in sec 15 | 35
angle | max. noise level 45° | 38 dB (A)
Cat. No. 5616 30)
Tubes
capacity in ml 25 50
Ø x L in mm 24x146.5 38x148.5
max. RCF 2.1) 783 805
radius in mm 175 180
Cat. No. 0532 0533
+
Adapter
boring Ø x L in mm 25 x 86 38.5x89.9
tubes per rotor 6 6
Cat. No. 4317 -
Rotor
max. RPM | max. RCF 2,000 min-1 | 917
max. capactiy 6 x 30 ml
run-up | run-down, braked in sec 15 | 20
angle | max. noise level 90° | 38 dB (A)
Cat. No. 4619 30)
Tubes
capacity in ml 30 30 2 Please note that the RCF values indicated refer only to rotor perfor-
Ø x L in mm 24 x 151 24 x 151 mance. The max. permissible RCF of tubes used should be verified
with the individual manufacturers. The max. RCF for glass tubes
max. RCF 2.1) 917 917
annotated with footnote 2) is 4,000.
radius in mm 206 206 2.1) Please note that the RCF values indicated refer only to rotor
Cat. No. 0529 0508 6) performance. The max. permissible RCF of vessels used should be
+
verified with the individual manufacturers.The max. RCF for ASTM
Tubes annotated with footnote 2) is 700.
3.11) When using these tubes, bucket 5051 cannot be closed with lid 5053.
4) Please remove the spacer.
6) A rubber stopper for closing the tube for agitating or mixing is
Adapter
available under Cat. No. 0535. The tube may not be centrifuged
boring Ø x L in mm - - with the stopper.
tubes per rotor 6 6 15) Also available with decanting aid. (Cat. No. 5247-91 or 5248-91).
30) In the heatable models 5660-50, 5660-51, 5660-70, 5670-50 and
Cat. No. - - 5675-50, rotor 4619 may only be used up to a maximum of +40 °C.
130
SWING-OUT ROTOR, 4-PLACE | 4474
+
Rotor Bucket
ROTOFIX 46 | 46 H
max. RPM | max. RCF 2,000 min-1 | 984 Cat. No. 4275
max. capactiy 4 x 100 ml
run-up | run-down, braked in sec 16 | 40
angle | max. noise level 90° | 58 dB (A)
Cat. No. 4474
Tubes
capacity in ml 50 100 100 100 50
Ø x L in mm 45 x 130 58 x 161 44 x 168 37 x 200 36.5 x 185
max. RCF 2.1) 984 984 961 961 912
radius in mm 220 220 215 215 204
Cat. No. ASTM 2.1) 0528 2.1) ASTM 2.1) 05312.1) Babcock
+
Adapter
boring Ø x L in mm - - - - -
tubes per rotor 4 4 4 4 4
Cat. No. 4278-A 0771 4277 4276-B 0703-A
+
Rotor Bucket
max. RPM | max. RCF 4,000 min-1 | 3,095 lid 5053
max. capactiy 4 x 100 ml Cat. No. 5051
run-up | run-down, braked in sec 40 | 45
angle | max. noise level 90° | 58 dB (A)
Cat. No. 5694
Tubes
capacity in ml 3 5 6 7 9 15 25 50 100 100 15 50 12 30 50
Ø x L in mm 10 x 60 12 x 75 12 x 82 12 x 100 14 x 100 17 x 100 24 x 100 34 x 100 44 x 100 40 x 115 17 x 120 29 x 115 17 x 100 25 x 110 29 x 115
max. RCF 2) 2,737 2,773 2,773 2,755 2,773 2,755 2,755 2,755 2,755 2,755 2,898 2,826 2,898 2,755 2,755
radius in mm 153 155 155 154 155 154 154 154 154 154 162 158 162 154 154
Cat. No. tubes 2) tubes with screw cap
+
Adapter
boring Ø x L in mm 11 x 44 12.5 x 42 12.5 x 42 12.5 x 86 16 x 50 17.5 x 86 26 x 86 36 x 86 45.5 x 86 42 x 86 17 x 90 30 x 86 17 x 90 26 x 86 36 x 86
tubes per rotor 80 80 80 80 48 48 20 8 4 4 28 8 28 20 8
Cat. No. 5267 5227 5227 5247 15) 5264 5248 15) 5242 5243 5262 5249 6306 5259 6306 5266 5243 4)
131
ROTOFIX 46 | 46 H | BENCHTOP CENTRIFUGES
+
Rotor Bucket
max. RPM | max. RCF 2) 4,000 min-1 | 3,095 lid bioseal 5) 5093
max. capactiy 4 x 290 ml Cat. No. 5092
run-up | run-down, braked in sec 40 | 45
angle | max. noise level 90° | 58 dB (A)
Cat. No. 5694
Tubes
capacity in ml 4 5 6 7 15 25 50 100 100 250 15 50 12 25 30
Ø x L in mm 12 x 60 12 x 75 12 x 82 12 x 100 17 x 100 24 x 100 34 x 100 44 x 100 40 x 115 65 x 115 17 x 120 29 x 115 17 x 100 25 x 90 25 x 110
max. RCF 2) 3,005 3,005 3,005 3,005 2,952 2,898 2,952 2,952 2,952 3,095 3,095 3,095 3,005 2,826 2,898
radius in mm 168 168 168 168 165 162 165 165 165 173 173 173 168 158 162
Cat. No. tubes 2) tubes with screw cap
+
Adapter
boring Ø x L in mm 12.8 x 45 12.8 x 45 12.8 x 45 13.2x82 17.5 x 60.7 25.5 x 82 35.5 x 82.5 45.5 x 85 42 x 85 66 x 103 17 x 85 30 x 85 17.5 x 82 26 x 73 25.5 x 82
tubes per rotor 48 48 48 48 32 16 4 4 4 4 28 8 28 12 16
Cat. No. 5128 5128 5128 5120 5136 5122 5124 5125 5126 1791 5129 5123 5121 5134 5122
Tubes
capacity in ml 50 10 250 290
Ø x L in mm 29 x 115 16 x 80 61 x 122 62 x 137
max. RCF 2) 3,023 2,952 3,095 3,095
radius in mm 169 165 173 173
Cat. No. tubes with 5127 24) - 24)
+
screw cap
Adapter
boring Ø x L in mm 30 x 99 17.5 x 60.7 66 x 103 66 x 103
tubes per rotor 8 32 4 4
Cat. No. 5135 5136 6319 6319
2) Please note that the RCF values indicated refer only to rotor performance. The max. permissible RCF of tubes used should be verified with the individual manufacturers.
The max. RCF for glass tubes annotated with footnote 2) is 4,000.
5) Tested by the TÜV in conformity with DIN EN 61010, section 2 - 020.
24) At temperatures of over +40 °C and / or when not filled to capacity, bottles may warp during centrifugation.
132
DID YOU KNOW?
ROTOFIX 46 | 46 H
The Download Center on our website allows you to access the most up to date
documents including catalogs, brochures, data sheets and certificates.
Try it now: www.hettichlab.com/downloadcenter
133
FLOORSTANDING CENTRIFUGES
High performance, throughput and capacity
136
TECHNICAL DATA
ROTANTA 460 RC ROTANTA 460 RF
refrigerated refrigerated
voltage *) 200 – 240 V 1 ~ 200 – 240 V 1 ~
frequency 50 Hz 50 Hz
consumption 1,800 VA 2,000 VA
emission, immunity EN / IEC 61326-1, class B EN / IEC 61326-1, class B
max. capacity 4 x 750 ml 4 x 750 ml
max. RPM 15,000 min-1 15,000 min-1
max. RCF 24,400 24,400
running time 1 – 99 h: 59 min: 59 s, continuous run, 1 – 99 h: 59 min: 59 s, continuous run,
460 RC | 460 RF
short cycle mode short cycle mode
ROTANTA
dimensions (W x D x H) 554 x 697 x 683 mm 554 x 697 x 961 mm
weight approx. 140 kg approx. 164 kg
noise level 60 dB (A) with rotor 4474 60 dB (A) with rotor 4474
temperature control, infinitely variable from -20 to +40 °C from -20 to +40 °C
Cat. No. 5670 5675
5,900 min-1 /
swing-out rotor, 2-place 90° 12 plates 5622 123
6,200 min-1
ANGLE ROTORS
8,500 min-1/
angle rotor, 6-place 25° 6 x 250 ml 5645 124
9,500 min-1
137
ROTIXA 500 RS
Small footprint – high volumes
Its durable components make the ROTIXA 500 RS a reliable unit with a long service life. High sample capacity and maxi-
mum RCF of 18,038 make it suitable for 4 x 450-1,000 ml blood bags. Specially designed buckets keep blood bags upright
during centrifugation for improved separation of blood components.
In industrial research labs, it accomodates 4 bottles up to 1,000 ml, specialty racks, as well as container and vessels for
various applications. This unit includes refigeration with a temperature range from -20°C to +40°C.
138
TECHNICAL DATA
ROTIXA 500 RS >)
refrigerated
voltage *) 230 – 240 V 1 ~ 220 V 1 ~
frequency 50 Hz 60 Hz
consumption 3,800 VA
emission, immunity EN / IEC 61326-1, class B
max. capacity 4 x 1,000 ml
max. RPM 11,500 min-1
max. RCF 18,038
running time 1 – 999 min: 59 s, continuous run
ROTIXA 500 RS
dimensions (W x D x H) 650 x 814 x 973 mm
weight approx. 219 kg
noise level 58 dB (A) with rotor 4282
temperature control, infinitely variable from -20 to +40 °C
Cat. No. 4950
AVAILABLE ROTORS
SWING-OUT ROTORS angle max. RPM max. capacity Cat. No. page
ANGLE ROTORS
139
ROTIXA 500 RS | FLOORSTANDING CENTRIFUGES
Rotor
max. RPM | max. RCF 2)
max. capactiy
4,500 min-1 | 4,958
4 x 750 ml
+ Bucket
lid
Cat. No.
4229-B
4295-A
run-up | run-down, braked in sec 115 | 116
angle | temperature in °C 1) 90° | +6
Cat. No. 4294
Tubes
capacity in ml 0.8 1.5 2.0 4 5 6 7 9 12 15 25 50 94 100
Ø x L in mm 8 x 45 11 x 38 11 x 38 10 x 88 12 x 75 12 x 82 12 x 100 14 x 100 16 x 101 17 x 100 24 x 100 34 x 100 38 x 102 40 x 115
max. RCF 2) 4,777 3,690 4,867 4,777 4,777 4,777 4,777 4,777 4,777 4,777 4,777 4,777 4,777 4,777
radius in mm 211 163 215 211 211 211 211 211 211 211 211 211 211 211
Cat. No. microliter tubes tubes 2)
+
Adapter
boring Ø x L in mm 8.2 x 36 11.2 x 46 11.2 x 46 11 x 74 12.5 x 36 12.5 x 74 12.5 x 74 16 x 74 16 x 74 17.5 x 74 26 x 74 35 x 74 41.5 x 74 41.5 x 74
tubes per rotor 312 336 336 252 192 192 192 100 100 120 44 24 16 16
Cat. No. 4226 4225 4225 4224 4213-93 4213 4213 4223 4223 4214 4215 4216 4218 4218
3.13) 3.13)
Tubes
capacity in ml 2.6–3.4 2.7–3 4–5.5 4.5–5 7.5–8.5 9–10 10 1.6–5 4–7 4–7 8 8.5 – 10 15 50
Ø x L in mm 13 x 65 11 x 66 15 x 75 11 x 92 15 x 92 16 x 92 15 x 102 13 x 75 13 x 100 16 x 75 16 x 125 16 x 100 17 x 120 29 x 115
max. RCF 2) 4,777 4,777 4,777 4,777 4,777 4,777 4,777 4,777 4,777 4,777 4,777 4,777 4,958 4,958
radius in mm 211 211 211 211 211 211 211 211 211 211 211 211 219 219
Cat. No. blood collection / urine tubes tubes with
+
screw cap
Adapter
boring Ø x L in mm 13.2 x 36 12.5 x 36 17.5 x 36 12.5 x 74 17.5 x 74 17.5 x 74 17.5 x 74 13.2 x 36 13.2 x 74 17.5 x 36 16 x 74 17.5 x 74 17 x 70 30 x 70
tubes per rotor 120 192 120 192 120 64 120 120 120 120 100 120 92 32
Cat. No. 4222-93 4213-93 4214-93 4213 4214 4220 4214 4222-93 4222 4214-93 4223 4214 4232 4245-A
3.13) 3.13)
Tubes
capacity in ml 12 30 50 100 100 250 290 600 650 750 750 250 500
Ø x L in mm 17 x 100 25 x 110 29 x 115 40 x 115 40 x 115 61 x 122 62 x 137 93 x 137 97 x 139 97 x 152 96 x 135 60 x 162 96 x 147
max. RCF 2) 4,777 4,777 4,867 4,777 4,777 4,777 4,777 4,958 4,958 4,958 4,958 4,777 4,958
radius in mm 211 211 215 211 211 211 211 219 219 219 219 219211
0551 24) 0554 24) 0512 24) 4234-A Corning® Corning
®
Cat. No. tubes with screw cap 5127 24) - 24)
+
+4449
Adapter
boring Ø x L in mm 17.5 x 74 26 x 74 30 x 96 41.5 x 74 41.5 x 74 62 x 90 62 x 90 94 x 105 97.5 x 105 97.5 x 105 97.5 x 105 61 x 125 97.5 x 105
tubes per rotor 64 44 24 16 16 4 4 4 4 4 4 4 4
Cat. No. 4220 4215 4249 4218 4218 4238 4238 4233 4258 4258 4258 6322 4258
140
SWING-OUT ROTOR, 4-PLACE | 4294
+
Rotor Bucket
max. RPM | max. RCF 2) 4.500 min-1 | 4.618 lid bioseal 5) 4291
max. capactiy 40 x 50 ml Cat. No. 4290
run-up | run-down, braked in sec 115 | 116
angle 90°
temperature in °C 1) +2
Cat. No. 4294
ROTIXA 500 RS
Tubes
capacity in ml 5 6 7 9 12 2.6–3.4 4.9 4–5.5 7.5–8.5 9–10 10 1.6–5 4–7 4–7 8.5 – 10
Ø x L in mm 12 x 75 12 x 82 12 x 100 14x100 16 x 101 13 x 65 13 x 90 15 x 75 15 x 92 16 x 92 15 x 102 13 x 75 13 x 100 16 x 75 16 x 100
max. RCF 2) 4,551 4,551 4,551 4,551 4,551 4,551 4,551 4,551 4,551 4,573 4,573 4,551 4,551 4,551 4,551
radius in mm 201 201 201 201 201 201 201 201 201 202 202 201 201 201 201
Cat. No. tubes 2) blood collection / urine tubes
+
Adapter
boring Ø x L in mm 13.2 x 57 13.2 x 57 13.2 x 57 17.5 x 62 17.5 x 62 13.2 x 57 13.2 x 57 17.5 x 62 17.5 x 62 17.5 x 63 17.5 x 63 13.2 x 57 13.2 x 57 17.5 x 62 17.5 x 62
tubes per rotor 200 200 200 168 168 200 200 168 168 132 132 200 200 168 168
Cat. No. 4273 4273 4273 4338 4338 4273 4273 4338 4338 4311 4311 4273 4273 4338 4338
Tubes
capacity in ml 15 10 12 15 15 50 50 50 50
Ø x L in mm 17 x 100 16 x 80 17 x 100 17 x 120 17 x 120 29 x 115 29 x 115 29 x 115 29 x 115
max. RCF 2) 4,551 4,551 4,437 4,618 4,618 4,618 4,618 4,528 4,528
radius in mm 201 201 196 204 204 204 204 200 200
Cat. No. - 2) tubes with screw cap
+
Adapter
boring Ø x L in mm 17.5 x 62 17.5 x 62 17.2 x 57 17 x 60 17 x 60 30 x 60 30 x 60 30 x 56 30 x 56
tubes per rotor 168 168 112 68 112 32 40 32 40
Cat. No. 4338 4338 4310 4314 4320 3.12) 4321 4323 3.12) 4313 4339 3.12)
1) For cooled versions: Lowest temperature achievable with precooling and max. speed.
2) Please note that the RCF values indicated refer only to rotor performance. The max. permissible RCF of tubes used should be verified with the individual manufacturers.
The max. RCF for glass tubes annotated with footnote 2) is 4,000.
3.12) When using these tubes, bucket 4290 cannot be closed with lid 4291.
3.13) When using these tubes, bucket 4295-A cannot be closed with lid 4229-B.
24) At temperatures of over +40 °C and / or when not filled to capacity, bottles may warp during centrifugation.
141
ROTIXA 500 RS | FLOORSTANDING CENTRIFUGES
+
Rotor Bucket
max. RPM | max. RCF 2) 4,500 min-1 | 4,573 lid bioseal 5) 5629
max. capactiy 24 plates Cat. No. 4280
run-up | run-down, braked in sec 115 | 116
angle | temperature in °C 1) 90° | +5
Cat. No. 4294
Plates
W x D x H in mm 128 x 86 x 15 128 x 86 x 17.5 128 x 86 x 22 128 x 86 x 44.5 128 x 86 x 46 128 x 86 x 83 124 x 82 x 20 -
capacity in ml - - - - - - - 0.2
max. RCF 2) 4,573 4,573 4,573 4,573 4,573 4,573 4,573 4,573
radius in mm 202 202 202 202 202 202 202 202
Cat. No. MTP MTP CP DWP MS QP PCR plates PCR strips
+
96-places
Removal aid
boring Ø x L in mm - - - - - - - -
plates / strips per rotor 24 24 20 8 4 4 4 48 x 8
Cat. No. 4279 4279 4279 4279 4279 4279 4279 + 1485 4279 + 1485
+
Rotor Bucket
max. RPM | max. RCF 2) 4,500 min-1 | 4,867 Cat. No. 4257
max. capactiy 20 Racks
run-up | run-down, braked in sec 115 | 116
angle | temperature in °C 1) 90° | +7
Cat. No. 4294
Rack
W x D x H in mm 118 x 20 x 70
capacity in ml -
max. RCF 2) 4,867
radius in mm 215
Cat. No. Hitachi Rack
+
Removal aid
1) For cooled versions: Lowest temperature achievable with
precooling and max. speed.
2) Please note that the RCF values indicated refer only to
rotor performance. The max. permissible RCF of tubes
used should be verified with the individual manufacturers.
boring Ø x L in mm - The max. RCF for glass tubes annotated with footnote 2)
tubes per rotor 20 is 4,000.
23) When using removal frame 4259-A, please take the
Cat. No. 4259-A 23) spacer out of carrier 4257.
142
SWING-OUT ROTOR, 4-PLACE | 4294
Rotor
max. RPM | max. RCF 2)
max. capactiy
4,500 min-1 | 5,184
4 x 1,000 ml
+ Bucket
adapter including lid
Cat. No.
4255
4254
run-up | run-down, braked in sec 115 | 116
angle | temperature in °C 1) 90° | +5
Cat. No. 4294
3.15)
ROTIXA 500 RS
Tubes
capacity in ml 5 7 9 15 25 50 100 2.6–3.4 2.7–3 4–5.5 4.5–5 4.9 7.5–8.5 9 – 10 10
Ø x L in mm 12 x 75 12 x 100 14x 100 17 x 100 24 x 100 34 x 100 44 x 100 13 x 65 11 x 66 15 x 75 11 x 92 13 x 90 15 x 92 16 x 92 15 x 102
max. RCF 2) 4,618 4,618 4,777 4,777 4,505 4,573 4,551 4,618 4,618 4,777 4,618 4,618 4,777 4,777 4,777
radius in mm 204 204 211 211 199 202 201 204 204 211 204 204 211 211 211
Cat. No. tubes 2) blood collection / urine tubes
+
+ 0726
Adapter
boring Ø x L in mm 13 x 58 13 x 58 17.5 x 53 17.5 x 53 26 x 72 36 x 79 45 x 78 13.5 x 58 13 x 58 17.5 x 53 13 x 58 13.5 x 58 17.5 x 53 17.5 x 53 17.5 x 53
tubes per rotor 120 120 76 76 28 16 8 84 120 76 120 84 76 76 76
Cat. No. 4433 4433 4434 4434 4438 4439 4442 4435 4433 4434 4433 4435 4434 4434 4434
Tubes
capacity in ml 1.6 – 5 4–7 4–7 8 8.5 – 10 15 30 50 25 30 10 250 290 650 750
Ø x L in mm 13 x 75 13x 100 16x 75 16 x 125 16 x 100 17 x 120 25 x 110 29 x 115 25 x 90 25 x 110 16 x 80 61 x 122 62 x 137 97 x 139 97 x 152
max. RCF 2) 4,618 4,618 4,777 4,777 4,777 4,890 4,709 4,890 4,709 4,709 4,777 5,003 5,003 5,184 5,184
radius in mm 204 204 211 211 211 216 208 216 208 208 211 221 221 229 229
Cat. No. blood collection / urine tubes tubes with screw cap 5127 24) - 24) 0554 24) 0512 24)
+
Adapter
boring Ø x L in mm 13.5 x 58 13.5 x 58 17.5 x 53 17.5 x 53 17.5 x 53 17 x 88 26 x 72 30 x 87 26 x 72 26 x 72 17.5 x 53 62 x 92 62 x 92 98 x 138 98 x 138
tubes per rotor 84 84 76 76 76 48 28 20 28 28 76 4 4 4 4
Cat. No. 4435 4435 4434 4434 4434 4437 4438 4441 4438 4438 4434 4443 4443 - -
Tubes
capacity in ml 1,000 1,000 175 175 200 225 250 500
Ø x L in mm 96 x 176 98 x 138 61 x 118 61,5 x 144 60 x 130 61 x 137 60 x 162 96 x 147
max. RCF 2) 5,184 5,184 5,184 5,184 5,184 5,184 5,184 5,184
radius in mm 229 229 229 229 229 229 229 229
Cat. No. 4239 24) 4255 Falcon Nalgene Nunc® Falcon Corning® Corning® 1) For cooled versions: Lowest temperature achievable with
+
precooling and max. speed.
2) Please note that the RCF values indicated refer only to
rotor performance. The max. permissible RCF of tubes
used should be verified with the individual manufacturers.
The max. RCF for glass tubes annotated with footnote 2)
Adapter
is 4,000.
boring Ø x L in mm 98 x 138 - - - - - - - 3.15) When using these tubes, bucket 4255 cannot be closed
tubes per rotor 4 4 4 4 4 4 4 4 with its lid.
24) At temperatures of over +40 °C and / or when not filled
Cat. No. - - 4440 4430 4430 4440 4430 4449 to capacity, bottles may warp during centrifugation.
143
ROTIXA 500 RS | FLOORSTANDING CENTRIFUGES
Rotor
max. RPM | max. RCF 2)
max. capactiy
4,500 min-1 | 5,252
4 blood bags
+ Bucket
Cat. No. 4293
Blood bags
capacity in ml 450 500
blood bags 3-place 3-place
max. RCF 2) 5,252 5,252
radius in mm 232 232
Cat. No. blood bags
+
Insert
boring Ø x L in mm - -
blood bags per rotor
Cat. No.
4
4244-A 4244-A
4
+ Additional blood bank accessories can be
found on page 183
Rotor
max. RPM | max. RCF 2)
max. capactiy
4,500 min-1 | 5,071
4 blood bags
+ Bucket
Cat. No. 4298-A
Blood bags
capacity in ml 450 500 750 1,000
blood bags 4-place 4-place 1-place 1-place
max. RCF 2) 5,003 5,003 5,003 5,071
+
radius in mm 221 221 221 224
Additional blood bank accessories can be
Cat. No. blood bags found on page 183
+
Insert
1) Lowest attainable temperature in precooled refrigerated
centrifuges at max. speed. Lower temperatures can be
attained by reducing the speed.
2) Please note that the RCF values indicated refer only to
boring Ø x L in mm - - - - rotor performance. The max. permissible RCF of tubes
blood bags per rotor 4 4 4 4 used should be verified with the individual manufacturers.
The max. RCF for glass tubes annotated with footnote 2)
Cat. No. 4237-A 4237-A 4237-A - is 4,000.
144
SWING-OUT ROTOR, 6-PLACE | 4296
+
Rotor Bucket
max. RPM | max. RCF 2) 4,000 min-1 | 3,363 lid 5053
max. capactiy 6 x 100 ml Cat. No. 5051
run-up | run-down, braked in sec 33 | 50
angle | max. noise level 90° | 52 dB (A)
temperature in °C 1) 0
Cat. No. 4296
ROTIXA 500 RS
Vessels
capacity in ml 1.5 2 1.5 2 5 6 7 9 15 25 50 100 100 1 – 8
Ø x L in mm 11 x 38 11 x 38 11 x 38 11 x 38 12 x 75 12 x 82 12 x 100 14 x 100 17 x 100 24 x 100 34 x 100 44 x 100 40 x 115 simple / multiple
2,486 2,486
max. RCF 2) top / bottom / 3,363 / 3,363 3,363 3,363 3,309 3,309 3,291 3,309 3,291 3,291 3,291 3,291 3,291 2,290 / 3,274
139 139
radius in mm top / bottom / 188 / 188 188 188 185 185 184 185 184 184 184 184 184 128 / 183
Cat. No. microliter tubes tubes 2) cyto chambers
+
Adapter
boring Ø x L in mm 12.5 x 42 12.5 x 42 11.5 x 50 11.5 x 50 12.5 x 42 12.5 x 42 12.5 x 86 16 x 50 17.5 x 86 26 x 86 36 x 86 45.5 x 86 42 x 86 -
vessels per rotor 240 240 96 96 120 120 120 72 72 30 12 6 6 12
Cat. No. 5257 5257 5281 5281 5227 5227 5247 15) 5264 5248 15) 5242 5243 5262 5249 5280
Vessels
capacity in ml 1.1 – 1.4 2.6 – 3.4 2.7 – 3 4 – 5.5 4.5 – 5 4.9 7.5 – 8.5 9 – 10 10 1.6 – 5 4 – 7 4 – 7 8.5 – 10 15 50
Ø x L in mm 8 x 66 13 x 65 11 x 66 15 x 75 11 x 92 13 x 90 15 x 92 16 x 92 15 x 102 13 x 75 13 x 100 16 x 75 16 x 100 17 x 120 29 x 115
max. RCF 2) 3,274 3,345 3,309 3,309 3,309 3,345 3,309 3,291 3,291 3,345 3,345 3,309 3,291 3,434 3,363
radius in mm 183 187 185 185 185 187 185 184 184 187 184 185 184 192 188
Cat. No. blood collection / urine tubes tubes with
+
screw cap
Adapter
boring Ø x L in mm 11 x 44 13.5 x 52 12.5 x 42 16 x 50 12.5 x 42 13.5 x 52 16 x 50 17.6 x 86 17.6 x 86 13.5 x 52 13.5 x 86 16 x 50 17.5 x 86 17 x 90 30 x 86
vessels per rotor 120 72 120 72 120 72 72 66 66 72 72 72 72 42 12
Cat. No. 5267 5268 5227 5264 5227 5268 5264 5258 5258 5268 6301 5264 5248 6306 5259
3.11) 3.11)
Vessels
capacity in ml 12 30 50
Ø x L in mm 17 x 100 25 x 110 29 x 115
max. RCF 2) 3,434 3,291 3,291
radius in mm 192 184 184
Cyto system available for this model.
Cat. No. tubes with screw cap CYTO
+
More information on page 178
+ 6316
145
ROTIXA 500 RS | FLOORSTANDING CENTRIFUGES
+
Rotor Bucket
max. RPM | max. RCF 4,000 min-1 | 3,631 lid bioseal 5) 5093
max. capacity 6 x 250 ml Cat. No. 5092
run-up | run-down, braked in sec 33 | 50
angle | max. noise level 90° | 59 dB (A)
temperature in °C 1) -2
Cat. No. 4296
Vessels
capacity in ml 5 6 7 15 25 50 100 100 250 1.1–1.4 1.1–1.4 2.6–3.4 2.7–3 2.7–3 4.9
Ø x L in mm 12 x 75 12 x 82 12 x 100 17 x 100 24 x 100 34 x 100 44 x 100 40 x 115 65 x 115 8 x 66 8 x 66 13 x 65 11 x 66 11 x 66 13 x 90
max. RCF 2) 3,542 3,542 3,542 3,488 3,434 3,488 3,488 3,488 3,631 3,488 3,077 3,077 3,488 3,077 3,488
radius in mm 198 198 198 195 192 195 195 195 203 195 172 172 195 172 195
Cat. No. tubes 2) blood collection / urine tubes
+
Adapter
boring Ø x L in mm 12.8 x 45 12.8 x 45 12.8 x 82 17.5 x 60.7 25.5 x 82 35.5 x 82.5 45.5 x 85 42 x 85 66 x 103 13.5 x 60.7 13 x 54.5 13 x 54.5 13.5x60.7 13 x 54.5 13.5 x 60.7
vessels per rotor 72 72 72 48 24 6 6 6 6 48 72 72 48 72 48
Cat. No. 5128 5128 5120 5136 5122 5124 5125 5126 1791 5137 5138 5138 5137 5138 5137
3.4 )
Vessels
capacity in ml 4–4.5 4.5–5 7.5–8.5 9 – 10 10 1.6 – 5 4–7 4–7 8 8.5 – 10 15 50 25 30 50
Ø x L in mm 15 x 75 11 x 92 15 x 92 16 x 92 15 x 102 13 x 75 16 x 75 13 x 100 16 x 125 16 x 100 17 x 120 29 x 115 25 x 90 25 x 110 29 x 115
max. RCF 2) 3,488 3,542 3,488 3,488 3,488 3,077 3,488 3,542 3,542 3,488 3,631 3,631 3,363 3,434 3,560
radius in mm 195 198 195 195 195 172 195 198 198 195 203 203 188 192 199
Cat. No. blood collection / urine tubes tubes with screw cap
+
Adapter
boring Ø x L in mm 17.5 x 60.7 12.8 x 82 17.5 x 60.7 17.5 x 60.7 17.5 x 60.7 13 x 54,5 17.5 x 60.7 12.8 x 82 17.5 x 82 17.5 x 60.7 17 x 85 30 x 85 26 x 73 25.5 x 82 30 x 99
vessels per rotor 48 72 48 48 48 72 48 72 42 48 42 12 18 24 12
Cat. No. 5136 5120 5136 5136 5136 5138 5136 5120 51214) 5136 5129 5123 5134 5122 5135
3.4)
Vessels
capacity in ml 10 250 290
Ø x L in mm 16 x 80 61 x 122 62 x 137
max. RCF 2) 3,488 3,631 3,631
radius in mm 195 203 203
Cat. No. - 5127 24) - 24)
+
Adapter
1) Lowest attainable temperature in precooled refrigerated centrifuges at max. speed. Lower temperatures can
be attained by reducing the speed.
2) Please note that the RCF values indicated refer only to rotor performance. The max. permissible RCF of
tubes used should be verified with the individual manufacturers.
The max. RCF for glass tubes annotated with footnote 2) is 4,000.
boring Ø x L in mm 17.5 x 60.7 66 x 103 66 x 103 3.4) When using these tubes, bucket 5051 or 5092 cannot be closed with lid 5053 or 5093.
vessels per rotor 48 6 6 4) Please remove the spacer.
5) Tested by the TÜV in conformity with DIN EN 61010, section 2 - 020.
Cat. No. 5136 6319 6319 24) At temperatures of over +40 °C and / or when not filled to capacity, bottles may warp during centrifugation.
146
SWING-OUT ROTOR, 2-PLACE | 4282
+
Rotor Bucket
max. RPM | max. RCF 3,600 min-1 | 2,652 Cat. No. 4285-A
max. capacity 20 plates
run-up | run-down, braked in sec 87 | 94
angle | max. noise level 90° | 58 dB (A)
temperature in °C 1) -2
Cat. No. 4282
ROTIXA 500 RS
Plates
W x D x H in mm 128 x 86 x 15 128 x 86 x 17.5 128 x 86 x 22 128 x 86 x 44.5 84x 59 x 46 124 x 82 x 20 -
max. RCF 2) 2,434 2,434 2,434 2,434 2,434 2,434 2,434
radius in mm 168 168 168 168 168 168 168
Cat. No. MTP MTP CP DWP MS PCR plates PCR strips
+
Removal aid
boring Ø x L in mm - - - - - - -
plates / strips per rotor 16 16 12 4 4 4 48 x 8
Cat. No. 4281 4281 4281 4281 4281 4281+1485 4281+1485
Racks
W x D x H in mm 176 x 20 x 41 118 x 20 x 70 193 x 25 x 60 210 x 110x 44
max. RCF 2) 2,652 2,652 2,652 2,579
radius in mm 183 183 183 178
Cat. No. Olympus Hitachi Behring Rack,
+
Racks Racks Racks 50-place
Adapter
boring Ø x L in mm - - - -
plates / racks per rotor 12 20 10 2
Cat. No. 4283-B 4287-B 4288-A 4263-A
1) Lowest attainable temperature in precooled refrigerated centrifuges at max. speed. Lower temperatures can be attained by reducing the speed.
2) Please note that the RCF values indicated refer only to rotor performance. The max. permissible RCF of tubes used should be verified with the individual manufacturers.
The max. RCF for glass tubes annotated with footnote 2) is 4,000.
147
ROTIXA 500 RS | FLOORSTANDING CENTRIFUGES
+
Lid bioseal 5) and
Rotor phenol-resistant
max. RPM | max. RCF 9,500 min-1 | 14,025 Cat. No. INCLUSIVE
max. capacity 6 x 250 ml
run-up | run-down, braked in sec 82 | 96
angle 25°
temperature in °C 1) +2
Cat. No. 4266
Vessels
capacity in ml 15 25 94 15 50 10 30 50 85 94 250
Ø x L in mm 17 x 100 24 x 100 38 x 102 17 x 120 29 x 115 16x 80 26 x 95 29 x 107 38 x 106 38 x 102 61 x 122
max. RCF 2) 13,319 12,915 12,310 12,915 12,108 13,420 12,915 12,108 12,310 12,310 14,025
radius in mm 132 128 122 128 120 133 128 120 122 122 139
Cat. No. tubes 2) tubes with screw cap 5127 24)
+
Adapter
boring Ø x L in mm 17.6 x 83 26 x 80 38.6 x 88 17 x 106 30 x 100 16.6 x 70 26 x 80 29 x 90 38.6 x 88 38.6 x 88 61.5 x 109
vessels per rotor 42 18 6 30 6 48 18 6 6 6 6
Cat. No. 5646 5642 5644 5637 5638 5641 5642 5643 5644 5644 -
1) Lowest attainable temperature in precooled refrigerated centrifuges at max. speed. Lower temperatures can be attained by reducing the speed.
2) Please note that the RCF values indicated refer only to rotor performance. The max. permissible RCF of tubes used should be verified with the individual manufacturers.
The max. RCF for glass tubes annotated with footnote 2) is 4,000.
5) Tested by the TÜV in conformity with DIN EN 61010, section 2 - 020.
24) At temperatures of over +40 °C and / or when not filled to capacity, bottles may warp during centrifugation.
148
ANGLE ROTOR, 6-PLACE | 4246
angle 45°
temperature in °C 1) +4
Cat. No. 4246
ROTIXA 500 RS
Vessels
capacity in ml 0.5 1.5 2.0 3 15 25 50 94 7.5 – 8.5 9 – 10 10 8.5 – 10 5 15 50
Ø x L in mm 10.7 x 36 11 x 38 11 x 38 10 x 60 17 x 100 24 x 100 34 x 100 38 x 102 15 x 92 16 x 92 15 x 102 16 x 100 17 x 59 17 x 120 29 x 115
max. RCF 2) 17,299 17,299 17,299 17,299 17,003 16,560 17,743 18,038 17,003 17,003 17,003 17,003 16,856 17,299 17,595
radius in mm 117 117 117 117 115 112 120 122 115 115 115 115 114 117 119
Cat. No. pediatric microliter tubes tubes 2) blood collection / urine tubes - tubes with
+
screw cap
Adapter
boring Ø x L in mm 11.4 x 39 11.4 x 39 11.4 x 39 11.4 x 39 17.5 x 92 26 x 85 35 x 89 38.2 x 89.6 17.5 x 92 17.5 x 92 17.5 x 92 17.5 x 92 17 x 51 17 x 106 29.8 x 97
vessels per rotor 24 24 24 24 6 6 6 6 6 6 6 6 6 6 6
Cat. No. 1449 1449 1449 1449 1451 1447 1463 - 1451 1451 1451 1451 1476 1466 1454
Vessels
capacity in ml 10 30 50 85 94
Ø x L in mm 16 x 80 26 x 85 29 x 107 38 x 106 38 x 102
max. RCF 2) 17,003 16,560 17,299 18,038 18,038
radius in mm 115 112 117 122 122
Cat. No. tubes with screw cap
+
Adapter
boring Ø x L in mm 16.5 x 74 26 x 85 29 x 92 38 .2x89.6 38 .2x89.6
vessels per rotor 12 6 6 6 6
Cat. No. 1448 1447 1446 - -
1) Lowest attainable temperature in precooled refrigerated centrifuges at max. speed. Lower temperatures can be attained by reducing the speed.
2) Please note that the RCF values indicated refer only to rotor performance. The max. permissible RCF of tubes used should be verified with the individual manufacturers.
The max. RCF for glass tubes annotated with footnote 2) is 4,000.
5) Tested by the TÜV in conformity with DIN EN 61010, section 2 - 020.
149
ROTO SILENTA 630 RS
Your first choice up to 12 liters
The ROTO SILENTA 630 RS is highly rated in the rapid and efficient centrifugation of blood bags. It is able to spin up to
12 liter of sample or 12 blood bags per run. Four and six-place rotor options are also available to offer the best possible fit.
In industrial or R&D applications the ROTO SILENTA accommodates six vessels up to 2,000 ml each. This unit includes
refrigeration with a temperature range from -20°C to +40°C.
150
TECHNICAL DATA
ROTO SILENTA 630 RS >)
refrigerated
voltage *) 400 V 3 ~ + N
frequency 50 – 60 Hz
consumption 9,700 VA
emission, immunity EN / IEC 61326-1, class B
max. capacity 6 x 2,000 ml
max. RPM 6,000 min-1
max. RCF 6,520
running time 1 – 999 min: 59 s, continuous run
ROTO SILENTA
dimensions (W x D x H) 813 x 1,015 x 973 mm
630 RS
weight approx. 355 kg
temperature control, infinitely variable from -20 to +40 °C
Cat. No. 5005
AVAILABLE ROTORS
SWING-OUT ROTORS angle max. RPM max. capacity Cat. No. page
ANGLE ROTORS
151
ROTO SILENTA 630 RS | FLOORSTANDING CENTRIFUGES
+
Rotor Bucket
max. RPM 4,500 min-1 Cat. No. 4524-A
max. RCF Rotor 4176 / 4174 6,498 / 5,683
max. capacity 12 / 8 blood bag
run-up | run-down, braked in sec 125 | 197
angle | temperature in °C 1) 90° | +16 / +10
Cat. No. 4176 / 4174
Blood bag
capacity in ml 500 500 750
blood bag per system 4-place 4-place 1-place
max. RCF 26) Rotor 4176 / 4174 6,498 / 5,683 6,498 / 5,683 6,498 / 5,683
radius in mm 287 / 251 287 / 251 287 / 251
Cat. No. - - -
+
Insert
boring Ø x L in mm - - -
blood bag systems per rotor
Cat. No.
12 / 8
4529 26)-AO,-AM,-AU
12 / 8
4592-B
12 / 8
4592-B + Additional blood bank accessories can be
found on page 183
+
Rotor Bucket
max. RPM 4,500 min-1 Cat. No. 4546-A
max. RCF Rotor 4176 / 4174 6,271 / 5,479
max. capacity 12 / 8 blood bag
run-up | run-down, braked in sec 125 | 197
angle | temperature in °C 1) 90° | +10 / 0
Cat. No. 4176 / 4174
Blood bag
capacity in ml 450
blood bag per system 4-place
max. RCF Rotor 4176 / 4174 6,271 / 5,479
radius in mm 277 / 242
+
Cat. No. -
+
Additional blood bank accessories can be
found on page 183
Insert 1) For cooled versions: Lowest temperature achievable with precooling and
max. speed.
boring Ø x L in mm - 26) Includes blood bag hanging to prevent erythrocyte accumulation at low
blood bag systems per rotor 12 / 8 speeds. Different hanging heights allow customer-specific adjustments.
(4529-AO top, 4529-AM center, 4529-AU bottom). Hanging blood bags
Cat. No. 4559-A 4564 4566
may be centrifuged with a maximum RCF of 1,000.
152
SWING-OUT ROTOR, 6- / 4-PLACE | 4176 / 4174
+
Rotor Bucket
max. RPM 4,500 min-1 Cat. No. 4591-A
max. RCF Rotor 4176 / 4174 6,498 / 5,705
max. capacity 12 / 8 blood bag
run-up | run-down, braked in sec 125 | 197
angle | temperature in °C 1) 90° | +16 / +10
Cat. No. 4176 / 4174
ROTO SILENTA
630 RS
Blood bags
capacity in ml 450 500 750
blood bag per system 3-place 4-place 1-place
max. RCF Rotor 4176 / 4174 6,498 / 5,705 6,498 / 5,705 6,498 / 5,705
radius in mm 287 / 252 287 / 252 287 / 252
Cat. No. - - -
+
Insert
boring Ø x L in mm - - -
blood bag systems per rotor
Cat. No.
12 / 8
4598-A
12 / 8
4592-B
12 / 8
4592-B + Additional blood bank accessories can be
found on page 183
Rotor
max. RPM
max. RCF Rotor 4176 / 4174
3,500 min-1
3,848 / 3,328
+ Bucket
Cat. No. 4595-C 31)
Vessels
capacity in ml max. 1,600 35) 2,000
W x D x H in mm - 150 x 100 x 180
max. RCF Rotor 4176 / 4174 3,821 / 3,328 3,848 / -
radius in mm 279 / 243 281 / -
run-up, in sec 95 / 131 29 / -
run-down, braked in sec 197 / 197 41 / -
Cat. No. - 0550 24)
+
Insert
1) For cooled versions: Lowest temperature achievable with precooling and
max. speed.
24) At temperatures of over +40 °C and / or when not filled to capacity, bottles
W x D x H in mm 145 x 91 x 146 - may warp during centrifugation.
31) Adapter for accommodating sample tubes and blood collection tubes in
vessels per rotor 6/4 6/-
carrier 4595-C on request.
Cat. No. 4596-A - 35) Depending on the sample.
153
ROTO SILENTA 630 RS | FLOORSTANDING CENTRIFUGES
Rotor
max. RPM
max. RCF Rotor 4176 / 4174
4,500 min-1
6,520 / 5,705
+ Bucket
Cat. No. 4523-A
Blood bags
capacity in ml 500 750 1,000
blood bag per system 4-place 1-place 1-place
max. RCF Rotor 4176 / 4174 6,475 / 6,475 5,660 / 5,660 6,520 / 5,705
radius in mm 285 / 250 285 / 250 288 / 252
Cat. No. - - -
+
Insert
boring Ø x L in mm - - -
blood bag systems per rotor
Cat. No.
6/4
4516-A
6/4
4516-A
6/4
- + Additional blood bank accessories can be
found on page 183
+
Rotor Bucket
max. RPM 4,500 min-1 lid 5621
max. RCF Rotor 4176 / 4174 6,316 / 5,524 Cat. No. 4547-B
max. capacity 6 / 4 blood bag
run-up | run-down, braked in sec 125 | 197
angle | temperature in °C 1) 90° | +9 / -9
Cat. No. 4176 / 4174
Blood bags
capacity in ml 500 450
blood bag per system 4-place 3-place
max. RCF Rotor 4176 / 4174 6,316 / 5,524 6,316 / 5,524
radius in mm 279 / 244 279 / 244
Cat. No. - -
+
Insert
+ Additional blood bank accessories can be
found on page 183
boring Ø x L in mm - -
blood bag systems per rotor 6/4 6/4
1) For cooled versions: Lowest temperature achievable with precooling and
Cat. No. 4548 4548 max. speed.
154
SWING-OUT ROTOR, 6- / 4-PLACE | 4176 / 4174
+
Rotor Bucket
max. RPM 4,500 min-1 adapter including lid 4255
max. RCF Rotor 4176 / 4174 6,294 / 5,501 Cat. No. 4579-A
max. capacity 6/4 x 1,000 ml
run-up | run-down, braked in sec 125 | 197
angle | temperature in °C 1) 90° | +4 / -11
Cat. No. 4176 / 4174
ROTO SILENTA
630 RS
Vessels
capacity in ml 5 7 9 15 25 50 100 2.6–3.4 2.7–3 4–5.5 4.5–5 4.9 9 – 10 10 1.6 – 5
Ø x L in mm 12 x 75 12 x 100 14 x 100 17 x 100 24 x 100 34 x 100 44 x 100 13 x 65 11 x 66 15 x 75 11 x 92 13 x 90 16 x 92 15 x 102 13 x 75
max. RCF 2) Rotor 4176 / 4174 5,750 / 5,750 / 5,886 / 5,886 / 5,615 / 5,705 / 5,683 / 5,750 / 5,750 / 5,886 / 5,750 / 5,750 / 5,886 / 5,886 / 5,750 /
4,935 4,935 5,094 5,094 4,845 4,890 4,867 4,935 4,935 5,094 4,935 4,935 5,094 5,094 4,935
radius in mm 254 / 218 254 / 218 260 / 225 260 / 225 248 / 214 252 / 216 251 / 215 254 / 218 254 / 218 260 / 225 254 / 218 254 / 218 260 / 225 260 / 225 254 / 218
Cat. No. tubes 2) blood collection / urine tubes
+
+ 0726
Adapter
boring Ø x L in mm 13 x 58 13 x 58 17.5 x 53 17.5 x 53 26 x 72 36 x 79 45 x 78 13.5 x 58 13 x 58 17.5 x 53 13 x 58 13.5 x 58 17.5 x 53 17.5 x 53 13.5 x 58
vessels per rotor 180 / 120 180 / 120 114 / 76 114 / 76 42 / 28 24 / 16 12 / 8 126 / 84 180 / 120 114 / 76 180 / 120 126 / 84 114 / 76 114 / 76 126 / 84
Cat. No. 4433 4433 4434 4434 4438 4439 4442 4435 4433 4434 4433 4435 4434 4434 4435
Vessels
capacity in ml 4–7 4–7 8.5 – 10 15 50 25 30 10 250 290 650 750 1,000 1,000 175
Ø x L in mm 13 x 100 16 x 75 16 x 100 17 x 120 29 x 115 25 x 90 25 x 110 16 x 80 61 x 122 62 x 137 97 x 139 97 x 152 96 x 176 98 x 138 61 x 118
max. RCF 2) Rotor 4176 / 4174 5,750 / 5,886 / 5,886 / 6,022 / 5,999 / 5,818 / 5,818 / 5,886 / 6,113 / 6,113 / 6,294 / 6,294 / 6,294 / 6,294 / 6,294 /
4,935 5,094 5,094 5,207 5,207 5,026 5,026 5,094 5,320 5,320 5,501 5,501 5,501 5,501 5,501
radius in mm 254 / 218 260 / 225 260 / 225 266 / 230 265 / 230 257 / 222 257 / 222 260 / 225 270 / 235 270 / 235 278 / 243 278 / 243 278 / 243 278 / 243 278 / 243
blood collection / urine
Cat. No. tubes with screw cap 5127 24) - 24) 0554 24) 0512 24) 4239 24) 4255 Falcon
+
tubes
Adapter
boring Ø x L in mm 13.5 x 58 17.5 x 53 17.5 x 53 17 x 88 30 x 87 26 x 72 26 x 72 16 x 80 62 x 92 62 x 92 98 x 138 98 x 138 98 x 138 - 61 x 118
vessels per rotor 126 / 84 114 / 76 114 / 76 72 / 48 30 / 20 42 / 28 42 / 28 114 / 76 6/4 6/4 6/4 6/4 6/4 6/4 6/4
Cat. No. 4435 4434 4434 4437 4441 4438 4438 4434 4443 4443 - - - - 4440
Vessels
capacity in ml 175 200 225 250 500
Ø x L in mm 61 x 144 60 x 130 61 x 137 60 x 162 96 x 147
max. RCF 2) Rotor 4176 / 4174 6,294 / 6,294 / 6,294 / 6,294 / 6,294 /
5,501 5,501 5,501 5,501 5,501
radius in mm 278 / 243 278 / 243 278 / 243 278 / 243 278 / 243
Cat. No. Nalgene® Nunc® Falcon® Corning® Corning®
+
Adapter
1) For cooled versions: Lowest temperature achievable with precooling and
max. speed.
2) Please note that the RCF values indicated refer only to rotor performance.
The max. permissible RCF of tubes used should be verified with the indivi-
dual manufacturers.
boring Ø x L in mm - - - - - The max. RCF for glass tubes annotated with footnote 2) is 4,000.
vessels per rotor 6/4 6/4 6/4 6/4 6/4 3.15) When using these tubes, carrier 4255 cannot be closed with its lid.
24) At temperatures of over +40 °C and / or when not filled to capacity, bottles
Cat. No. 4430 4430 4440 4430 4449
may warp during centrifugation.
155
ROTO SILENTA 630 RS | FLOORSTANDING CENTRIFUGES
+
Rotor Bucket
max. RPM 4,500 min-1 Cat. No. 4522-A
max. RCF Rotor 4176 / 4174 5,999 / 5,184
max. capacity 6 x 750 ml
run-up | run-down, braked in sec 125 | 197
angle | temperature in °C 1) 90° | +14 / -1
Cat. No. 4176 / 4174
Vessels
capacity in ml 4 5 6 7 12 15 25 50 100 2.6–3.4 2.7–3 4–5.5 4.5–5 7.5 – 8.5 9 – 10
Ø x L in mm 10 x 88 12 x 75 12 x 82 12 x 100 16 x 101 17 x 100 24 x 100 34 x 100 44 x 115 13 x 65 11 x 66 15 x 75 11 x 92 15 x 92 16 x 92
max. RCF Rotor 4176 / 4174 5,818 / 5,818 / 5,818 / 5,818 / 5,818 / 5,818 / 5,818 / 5,818 / 5,818 / 5,818 / 5,818 / 5,818 / 5,818 / 5,818 / 5,818 /
5,003 5,003 5,003 5,003 5,003 5,003 5,003 5,003 5,003 5,003 5,003 5,003 5,003 5,003 5,003
radius in mm 257 / 221 257 / 221 257 / 221 257 / 221 257 / 221 257 / 221 257 / 221 257 / 221 257 / 221 257 / 221 257 / 221 257 / 221 257 / 221 257 / 221 257 / 221
Cat. No. tubes 2) blood collection / urine tubes
+
Adapter
boring Ø x L in mm 11 x 74 12.5 x 36 12.5 x 74 12.5 x 74 16 x 74 17.5 x 74 26 x 74 35 x 74 41.5 x 74 13.2 x 36 12.5 x 36 17.5 x 36 12.5 x 74 17.5 x 74 17.5 x 74
vessels per rotor 378 / 252 288 / 192 288 / 192 288 / 192 150 / 100 180 / 120 66 / 44 36 / 24 24 / 16 180 / 120 288 / 192 180 / 120 288 / 192 180 / 120 96 / 64
Cat. No. 4224 4213-93 4213 4213 4223 4214 4215 4216 4218 4222-93 4213-93 4214-93 4213 4214 4220
Vessels
capacity in ml 10 1.6 – 5 4–7 4–7 8 8.5 – 10 15 50 12 30 50 250 290 600 650
Ø x L in mm 15 x 102 13 x 75 16 x 75 13 x 100 16 x 125 16 x 100 17 x 120 29 x 115 17 x 100 25 x 110 29 x 115 61 x122 62 x 137 93 x 134 97 x 139
max. RCF Rotor 4176 / 4174 5,818 / 5,818 / 5,818 / 5,818 / 5,818 / 5,818 / 5,999 / 5,999 / 5,818 / 5,818 / 5,909 / 5,818 / 5,818 / 5,999 / 5,999 /
5,003 5,003 5,003 5,003 5,003 5,003 5,184 5,184 5,003 5,003 5,094 5,003 5,003 5,184 5,184
radius in mm 257 / 221 257 / 221 257 / 221 257 / 221 257 / 221 257 / 221 265 / 229 265 / 229 257 / 221 257 / 221 261 / 225 257 / 221 257 / 221 265 / 229 265 / 229
Cat. No. blood collection / urine tubes tubes with screw cap 5127 24) - 24) 0551 24) 0554 24)
+
Adapter
boring Ø x L in mm 17.5 x 74 13.2 x 36 17.5 x 36 13.2 x 74 16 x 74 17.5 x 74 17 x 70 30 x 70 17.5 x 74 26 x 74 30 x 96 62 x 90 62 x 90 94 x 105 97.5 x 105
vessels per rotor 180 / 120 180 / 120 180 / 120 180 / 120 150 / 100 180 / 120 138 / 92 48 / 32 96 / 64 66 / 44 36 / 24 6/4 6/4 6/4 6/4
Cat. No. 4214 4222-93 4214-93 4222 4223 4214 4232 4245-A 4220 4215 4249 4238 4238 4233 4258
Vessels
capacity in ml 750 750 250 500
Ø x L in mm 97 x 152 93 x 137 60 x 162 96 x 147
max. RCF Rotor 4176 / 4174 5,999 / 5,999 / 5,818 / 5,999 /
5,184 5,184 5,003 5,184
radius in mm 265 / 229 265 / 229 257 / 221 265 / 229
Cat. No. 0512 24) 4234-A Corning® Corning®
+ +4449 1) For cooled versions: Lowest temperature achievable with precooling and
max. speed.
2) Please note that the RCF values indicated refer only to rotor performance.
The max. permissible RCF of tubes used should be verified with the indivi-
Adapter dual manufacturers. The max. RCF for glass tubes annotated with footnote
boring Ø x L in mm 97.5 x 105 97.5 x 105 61 x 125 97.5 x 105 2) is 4,000.
vessels per rotor 6/4 6/4 6/4 6/4 5) Tested by the TÜV in conformity with DIN EN 61010, section 2 - 020.
24) At temperatures of over +40 °C and / or when not filled to capacity, bottles
Cat. No. 4258 4258 6322 4258 may warp during centrifugation.
156
SWING-OUT ROTOR, 6- / 4-PLACE | 4176 / 4174
+
Rotor Bucket
max. RPM 4,500 min-1 lid 5621
max. RCF Rotor 4176 / 4174 6,384 / 5,592 Cat. No. 4547-B
max. capacity 6 x 1,000 ml
run-up | run-down, braked in sec 125 | 197
angle | temperature in °C 1) 90° | +9 / -9
Cat. No. 4176 / 4174
ROTO SILENTA
630 RS
Vessels
capacity in ml 5 7 9 15 25 50 100 2.6–3.4 2.7–3 4–5.5 4.5–5 4.9 7.5–8.2 9 – 10 10
Ø x L in mm 12 x 75 12 x 100 14 x 100 17 x 100 24 x 100 34 x 100 44 x 100 13 x 65 11 x 66 15 x 75 11 x 92 13 x 90 15 x 92 16 x 92 15 x102
max. RCF 2) Rotor 4176 / 4174 5,841/ 5,841/ 5,977 / 5,977 / 5,728 / 5,773 / 5,750 / 5,841/ 5,841/ 5,977 / 5,841/ 5,841/ 5,977 / 5,977 / 5,977 /
5,026 5,026 5,184 5,184 4,913 4,981 4,958 5,026 5,026 5,184 5,026 5,026 5,184 5,184 5,184
radius in mm 258 / 222 258 / 222 264 / 229 264 / 229 253 / 217 255 / 220 254 / 219 258 / 222 258 / 222 264 / 229 258 / 222 258 / 222 264 / 229 264 / 229 264 / 229
Cat. No. tubes 2) blood collection / urine tubes
+
+ 0726
Adapter
boring Ø x L in mm 13 x 58 13 x 58 17.5 x 53 17.5 x 53 26 x 72 36 x 79 45 x 78 13.5 x 58 13 x 58 17.5 x 53 13 x 58 13.5 x 58 17.5 x 53 17.5 x 53 17.5 x 53
vessels per rotor 180 / 120 180 / 120 114 / 76 114 / 76 42 / 28 24 / 16 12 / 8 126 / 84 180 / 120 114 / 76 180 / 120 126 / 84 114 / 76 114 / 76 114 / 76
Cat. No. 4433 4433 4434 4434 4438 4439 4442 4435 4433 4434 4433 4435 4434 4434 4434
3.17)
Vessels
capacity in ml 1.6 – 5 4–7 4–7 8 8.5 – 10 15 50 25 30 10 250 290 650 750 1.000
Ø x L in mm 13 x 75 13 x100 16 x 75 16 x 125 16 x 100 17 x 120 29 x 115 25 x 90 25 x 110 16 x 80 62 x 122 62 x 137 97 x 139 97 x 152 96 x 176
max. RCF 2) Rotor 4176 / 4174 5,841 / 5,841 / 5,977 / 5,977 / 5,977 / 6,090 / 6,090 / 5,909 / 5,909 / 5,977 / 6,203 / 6,203 / 6,384 / 6,384 / 6,384 /
5,026 5,026 5,184 5,184 5,184 5,298 5,298 5,117 5,117 5,184 5,411 5,411 5,592 5,592 5,592
radius in mm 258 / 222 258 / 222 264 / 229 264 / 229 264 / 229 269 / 234 269 / 234 261 / 226 261 / 226 264 / 229 274 / 239 274 / 239 282 / 247 282 / 247 282 / 247
Cat. No. blood collection / urine tubes tubes with screw cap 5127 24) - 24) 0554 24) 0512 24) 4239 24)
+
Adapter
boring Ø x L in mm 13.5 x 58 13.5 x 58 17.5 x 53 17.5 x 53 17.5 x 53 17 x 88 30 x 87 26 x 72 26 x 72 17.5 x 53 62 x 92 62 x 92 98 x 141 98 x 141 98 x 141
vessels per rotor 126 / 84 126 / 84 114 / 76 114 / 76 114 / 76 72 / 48 30 / 20 42 / 28 42 / 28 114 / 76 6/4 6/4 6/4 6/4 6/4
Cat. No. 4435 4435 4434 4434 4434 4437 4441 4438 4438 4434 4443 4443 - - -
Vessels
capacity in ml 175 175 200 225 250 500
Ø x L in mm 61 x 118 61 x 144 60 x 130 61 x 137 60 x 162 96 x 147
max. RCF 2) Rotor 4176 / 4174 6,384 / 6,384 / 6,384 / 6,384 / 6,384 / 6,384 /
5,592 5,592 5,592 5,592 5,592 5,592
radius in mm 282 / 247 282 / 247 282 / 247 282 / 247 282 / 247 282 / 247
Cat. No. Falcon® Nalgene® Nunc® Falcon® Corning® Corning®
+
Adapter
1) For cooled versions: Lowest temperature achievable with precooling and
max. speed.
2) Please note that the RCF values indicated refer only to rotor performance.
The max. permissible RCF of tubes used should be verified with the indivi-
dual manufacturers. The max. RCF for glass tubes annotated with footnote
boring Ø x L in mm - - - - - - 2) is 4,000.
vessels per rotor 6/4 6/4 6/4 6/4 6/4 6/4 3.17) When using these tubes, bucket 4547-B cannot be closed with lid 5621.
24) At temperatures of over +40 °C and / or when not filled to capacity, bottles
Cat. No. 4440 4430 4430 4440 4430 4449 may warp during centrifugation.
157
ROTO SILENTA 630 RS | FLOORSTANDING CENTRIFUGES
Vessels
capacity in ml 15 25 94 15 50 10 30 50 85 94 250
Ø x L in mm 17 x 100 24 x 100 38 x 102 17 x 120 29 x 115 16 x 80 26 x 95 29 x 107 38 x 106 38 x 102 61 x 122
max. RCF 2) 5,315 5,152 4,910 5,152 4,830 5,353 5,152 4,830 4,910 4,910 5,594
radius in mm 132 128 122 128 120 133 128 120 122 122 139
Cat. No. tubes 2) tubes with screw cap 5127 24)
+
Adapter
boring Ø x L in mm 17.6 x 83 26 x 80 38.6 x 88 17 x 106 30 x 100 16.6 x 70 26 x 80 29 x 90 38.6 x 88 38.6 x 88 61.5 x 109
vessels per rotor 42 18 6 30 6 48 18 6 6 6 6
Cat. No. 5646 5642 5644 5637 5638 5641 5642 5643 5644 5644 -
1) For cooled versions: Lowest temperature achievable with precooling and max. speed.
2) Please note that the RCF values indicated refer only to rotor performance. The max. permissible RCF of tubes used should be verified with the individual manufacturers.
The max. RCF for glass tubes annotated with footnote 2) is 4,000.
5) Tested by the TÜV in conformity with DIN EN 61010, section 2 - 020.
24) At temperatures of over +40 °C and / or when not filled to capacity, bottles may warp during centrifugation.
158
159
ROTO SILENTA
630 RS
HETTINFO
HETTINFO II
DOCUMENTATION SYSTEM
HettInfo II documents important work steps before and during centrifugation
– this ensures transparency and traceable processes. The documentation
system is operated via a touch display, which guides the user step by step
through the centrifugation and records all significant process data.
All documented data points are temporarily stored locally and can be HettInfo II
exported directly after the centrifugation or at a defined time as a CSV file.
The data can be stored on the network or exported to a USB stick. This
makes HettInfo II system independent and facilitates further processing into Scan Module
another software system.
ADVANTAGES
Touch display
1
HettInfo II can be operated simply and easily via the touch display – even with laboratory gloves.
Step-by-step instructions
2 With the step-by-step instructions, the user always knows exactly what to do next. In the event of incorrect
operation or errors, a visual and audible message is issued immediately.
TECHNICAL FEATURES
160
MODULES
HETTINFO II
With HettInfo II you can record running data of your ROTO SILENTA 630
RS or ROTIXA 500 RS centrifuge. To record a complete centrifugation
process, we recommend HettInfo II plus Scan Module.
HETTINFO II
Articles Includes Cat. No
HettInfo II – ROTO SILENTA 630 RS Firmware, touch display 0955
HettInfo II – ROTIXA 500 RS Firmware, touch display 0956
SCAN MODULE
The barcode scanner included in the Scan Module records all data
reliably. The ergonomic holder ensures easy handling and offers secure
protection when not in use.
Barcode scanners from the HettInfo I series are compatible with HettInfo
II and can still be used.
ADD-ON KIT
With the Add-on Kit, ROTO SILENTA 630 RS models from model year 01/2008* can be upgraded to HettInfo II.
To capture a complete centrifugation process, we recommend the Add-on Kit plus Scan Module.
* Older models on request.
PRODUCT VIDEOS
Would you like to learn more about this product? Scan the QR Code to visit
our YouTube channel:
www.youtube.com/hettichlabtechnology
161
CELL WASHER
Automated cell washing centrifuge
ROTOLAVIT II
on page 164
CELL WASHER
ROTOLAVIT II
User friendly serology solutions
The ROTOLAVIT II cell washing system facilitates routine tasks in transfusion laboratories. It was developed for cross-
matching, as well as antibody search and differentiation, and for cell washing in TB tests. Its modern touch screen enables
the simple and rapid input of up to 20 different programs. The centrifuge has a small footprint and delivers reliable results
without the need for costly consumables.
164
TECHNICAL DATA
ROTOLAVIT II
voltage 100 – 240 V 1 ~
frequency 50 – 60 Hz
consumption 144 VA
emission, immunity EN / IEC 61326-3-2 / FCC CFR47 part 15, ed 2015-04-21 (e-CFR) class B
max. capacity 24 standard tubes (10 x 75 mm or 12 x 75 mm)
max. RPM 3,500 min-1
max. RCF 1,438
radius (both rotors) 105 mm
dimensions (H x W x D) 330 x 480 x 280 mm
weight approx. 24.5 kg
max. noise level ≤ 49 dB (A)
Cat. No. 1008-00
ROTOLAVIT II
AVAILABLE ROTORS
SWING-OUT ROTORS angle max. RPM max. capacity Cat. No page
12 x (10 x 75 mm* or 12 x 75 mm)
swing-out rotor, 12-place 45° 3,500 min 1017-A 166
* Tubes requires adapter No. 1019
24 x (10 x 75 mm* or 12 x 75 mm)
swing-out rotor, 24-place 45° 3,500 min 1018-A 166
* Tubes requires adapter No. 1019
165
ROTOLAVIT II | CELL WASHER
Rotor
max. RPM | max. RCF 3,500 min-1 | 1,438
max. capacity 12 x 5 ml
angle | max. noise level 45° | 49 dB (A)
Cat. No. 1017-A
Vessels
capacity in ml 3 5
Ø x L in mm 10 x 75 12 x 75
max. RCF 2) 1,438 1,438
radius in mm 105 105
Cat. No. tubes 2)
+
Adapter
boring Ø x L in mm - -
vessels per rotor 12 12
Cat. No. 1019 (12 pcs.) -
Rotor
max. RPM | max. RCF 3,500 min-1 | 1,438
max. capacity 24 x 5 ml
angle | max. noise level 45° | 49 dB (A)
Cat. No. 1018-A
Vessels
capacity in ml 3 5
Ø x L in mm 10 x 75 12 x 75
max. RCF 2) 1,438 1,438
radius in mm 105 105
Cat. No. tubes 2)
+
Adapter
boring Ø x L in mm - -
vessels per rotor 24 24
Cat. No. 1019 (12 pcs.) -
2) Please note that the RCF values indicated refer only to rotor performance. The max. permissible RCF of tubes used should be verified with the individual manufacturers.
The max. RCF for glass tubes annotated with footnote 2) is 4,000.
166
167
ROTOLAVIT II
DUAL CENTRIFUGE
Homogenizing, mixing and
milling – fast and efficient
ZENTRIMIX 380 R
on page 170
DUAL CENTRIFUGE
ZENTRIMIX 380 R
Efficient and safe work
in the laboratory
The dual centrifuge ZentriMix 380 R allows many challenging laboratory tasks in research, development and analytics in a
very efficient way or makes them possible for the first time. Examples are the rapid mixing of viscous materials, the produc-
tion of nanoparticles in closed (sterile) vessels or tissue disruption. A particular advantage is the powerful cooling system for
temperature-sensitive samples.
The ZentriMix 380 R was developed on the basis of proven Hettich centrifuge technology. This makes the device safe, reli-
able and durable. In addition, the compact design and the low noise level ensure a comfortable working environment in the
laboratory.
170
TECHNICAL DATA
ZentriMix 380 R
voltage 1)
200 – 240 V 1 ~ 110 – 127 V 1 ~
frequency 50 – 60 Hz 60 Hz
consumption 1,400 VA 1,600 VA
emission, immunity EN / IEC 61326-1, class B FCC class B
max. capacity 2 x 200 ml / 40 x 2.0 ml 2 x 200 ml / 40 x 2.0 ml
max. RPM (S rotor / Swing-out rotor, 4-place) 2,500 / 5,000 min-1 2,500 / 5,00 min-1
max. RCF (S rotor / Swing-out rotor, 4-place) 1,048 / 4,863 1,048 / 4,863
dimensions (W x D x H) 472 x 759 x 418 mm 472 x 769 x 418 mm
weight approx. 81.5 kg approx. 89 kg
Cat. No. 3200 3200-01
AVAILABLE ROTORS
ROTORS angle max. RPM max. capacity Cat. No. page
DUAL CENTRIFUGE
H rotor, 2-place 40° 1,500 min -1 2 x 200 ml 3206 172
Secondary rotation
Continuous directional change Sample movement during
Primary of the centrifugal acceleration in dual centrifugation
rotation the rotating sample vessel (black
arrow)
171
ZENTRIMIX 380 R | DUAL CENTRIFUGE
Rotor
max. RPM | max. RCF 1,500 min-1 | 377
max. capacity 2 x 200 ml
run-up | run-down, braked in sec 22 | 24
angle | temperature in °C 2) 40° | +20
Cat. No. 3206
Vessels
capacity in ml 15 50 150 200
Ø x L in mm 17 x 120 29 x 115 68 x 60 68 x 79
max. RCF 2) 377 377 377 377
radius in mm 150 150 150 150
jars with
Cat. No. tubes
+
screw cap
Adapter
vessels per rotor 6 6 2 2
Cat. No. 3218 3218 3221-A 3221-A
Rotor
max. RPM | max. RCF 2,500 min-1 | 1,048
max. capacity 2 x 200 ml
run-up | run-down, braked in sec 35 | 35
angle | temperature in °C 2) 40° | +20
Cat. No. 3205
37) 38.1)
Vessels
capacity in ml 2.0 10 150 200
Ø x L in mm 11 x 45.5 25.5 x 49 68 x 60 68 x 79
max. RCF 2) 1,048 1,048 1,048 1,048
radius in mm 150 150 150 150 Removal aid for Twist-Top disk 3236. 3210
3210
Cat. No. - - jars with
+
screw cap
39)
172
SWING-OUT ROTOR, 4-PLACE | 3234
Rotor
max. RPM | max. RCF
max. capacity
5,000 min-1 | 4,863
4 x 250 ml
+ Bucket
lid bioseal 5)
Cat. No.
1751
1752
run-up | run-down, braked in sec 42 | 27
angle 90°
Cat. No. 3234
38.2) 40)
Vessels
capacity in ml 10 9 15 94 100 100 250 15 50 30 50 250
Ø x L in mm 25.5 x 49 14 x 100 17 x 100 38 x 102 40 x 115 44 x 100 65 x 115 17 x 120 29 x 115 25 x 110 29 x 115 61 x 122
max. RCF 7) top / bottom 4,695 4,668 4,668 4,807 4,640 4,640 4,640 4,863 4,863 4,528 4,752 4,863
radius in mm top / bottom 168 167 167 172 166 166 166 174 174 162 170 174
Bestell-Nr. - tubes 7) tubes with screw cap
+
Adapter
boring Ø x L in mm 26 x 33 17.5 x 61 17.5 x 61 38.5 x 80 41 x 97 45 x 87 66 x 104.5 17 x 84 30 x 84 26.5 x 72 30 x 80 62 x 100
DUAL CENTRIFUGE
vessels per rotor 24 52 52 8 4 4 4 36 16 20 16 4
Cat. No. 3235 1763-A 1763-A 1777 1767 1766 1768 1771-A 1772-A 1779 1774-A 1769
PRODUCT VIDEOS
Would you like to learn more about this product? Scan the QR Code to visit
our YouTube channel:
www.youtube.com/hettichlabtechnology
173
AUTOMATED CENTRIFUGES
We are the world leader in automated centrifuges
Since the introduction of the first robotically integrated centrifuges over 25 years
ago, Hettich is still setting the benchmark in centrifuge automation technology.
Increased demands on security or flexibility as well as time and cost pressures represent a large challenge for today’s
cytology laboratory. Hettich's three cyto systems are available to tackle these challenges. Reliable, flexible and cost-saving
solutions – all IVD-compliant according to EU Directive 98/79/EC.
178
Assembly of a complete cyto insert
bucket
bucket
MOST POPULAR
+
UNIVERSAL 320 / 320 R Lid bioseal 5)
max. RPM | max. RCF 2,000 min-1 | 438 Cat. No. INCLUSIVE
max. capacity 12 cyto chambers
run-up | run-down, braked in sec 19 | 18
Angle 90° Stand
Cat. No. 1515-A Cat. No. 1528
EQUIPMENT
CYTO CHAMBERS
+ +
1534 (500 pcs.)
Clips Clips
(autoclavable) (autoclavable) 5) Tested by the TÜV in
Cat. No. 1524 (4 pcs.) 1524 (4 pcs.) Cat. No. 1524 (4 pcs.) 1524 (4 pcs.) conformity with DIN
+ +
EN 61010, section
2 - 020.
18) This is the maximum
capacity. The
Filter cards Filter cards / seals recommended
filter card white filter card brown quantity to be used
Cat. No. (inclusive) (inclusive) Cat. No. 1539 (200 pcs.) 1537 (100 pcs.) per chamber is 4 ml.
179
HETTICH CYTO SYSTEM
+
UNIVERSAL 320 / 320 R Bucket
max. RPM | max. RCF 4,000 min-1 | 2,451 lid 1661
max. capacity 8 cyto chambers Cat. No. 1660
run-up | run-down, braked in sec 22 | 25
angle 90°
Cat. No. 1624
+
Swing-out rotor, 4-place
For UNIVERSAL 320 / 320 R Bucket
max. RPM | max. RCF 5,000 min-1 | 2,879 Cat. No. 1452
max. capacity 8 cyto chambers
run-up | run-down, braked in sec 30 | 32
angle | temperature in °C 1) 90° | -10
Cat. No. 1494
+
For ROTINA 380 / 380 R Bucket
max. RPM | max. RCF 4,000 min-1 | 2,898 lid 5053
max. capacity 16 cyto chambers Cat. No. 5051
run-up | run-down, braked in sec 24 | 17
angle | temperature in °C 1) 90° | -8
Cat. No. 1798 Adapter
Cat. No. 5280
+
For ROTINA 420 / 420 R Bucket
max. RPM | max. RCF 4,000 min-1 | 2,898 lid 5053
max. capacity 16 cyto chambers Cat. No. 5051
run-up | run-down, braked in sec 18 | 16
angle | temperature in °C 1) 90° | -1
Cat. No. 4753 Adapter
Cat. No. 5280
+
/ 460 RC / 460 RF Bucket
max. RPM | max. RCF 4,000 min-1 | 3,095 lid 5053
max. capacity 16 cyto chambers Cat. No. 5051
run-up | run-down, braked in sec 40 | 45
angle 90°
Cat. No. 5694 Adapter
Cat. No. 5280
180
Swing-out rotor, 4-place
For ROTANTA 460 / 460 R
+
/ 460 RC / 460 RF Bucket
max. RPM | max. RCF 4,600 min-1 | 4,069 Cat. No. 5628
max. capacity 16 cyto chambers
run-up | run-down, braked in sec 75 | 88
angle | temperature in °C 1) 90° | +10 Adapter
Cat. No. 5699-R Cat. No. 5220-A
Adapter
Cat. No. 5280
+
UNIVERSAL 320 / 320 R Bucket
max. RPM | max. RCF 4,000 min-1 | 2,039 lid 1661
max. capacity 12 cyto chambers Cat. No. 1660
run-up | run-down, braked in sec 22 | 25
angle 90°
Cat. No. 1626
+
Passend für ROTINA 380
/ 380 R Bucket
max. RPM | max. RCF 4,000 min-1 | 2,003 lid 1661
max. capacity 12 cyto chambers Cat. No. 1660
run-up | run-down, braked in sec 19 | 18
angle | temperature in °C 1) 90° | -6
Cat. No. 1726
+
460 RC | 460 RF Bucket
max. RPM | max. RCF 4,000 min-1 | 3,291 lid 5053
EQUIPMENT
max. capacity 24 cyto chambers Cat. No. 5051
run-up | run-down, braked in sec 38 | 46
angle | temperature in °C 1) 90° | 0
Cat. No. 4446 Adapter
Cat. No. 5280
+
For ROTIXA 500 RS Bucket
max. RPM | max. RCF 4,000 min-1 | 3,274 lid 5053
max. capacity 24 cyto chambers Cat. No. 5051
run-up | run-down, braked in sec 33 | 50
angle | temperature in °C 1) 90° | 0
Cat. No. 4296 Adpater
Cat. No. 5280
181
HETTICH CYTO SYSTEM | ROLLING CABINETS | BLOOD BANK EQUIPMENT
CYTO CHAMBERS
Cyto chambers
capacity in ml 1 2 4 8 3x2 4x1
area in mm² 30 60 120 240 3 x 60 4 x 30
Ø in mm 6.2 8.7 12.4 17.5 3 x 8.7 4 x 6.2
Cat. No. 1663-100 (100 pcs.) 1664-100 (100 pcs.) 1665-100 (100 pcs.) 1666-100 (100 pcs.) 1667-100 (100 pcs.) 1668-100 (100 pcs.)
+
Slide carrier
Slide carrier Slide carrier Slide carrier Slide carrier Slide carrier Slide carrier Slide carrier Slide carrier Slide carrier Slide carrier Slide carrier Slide carrier
with ring for two
chambers
with ring for two
chambers
with ring for two
chambers
with ring for two
chambers
with ring for two
chambers
with ring for two
chambers
(autoclavable)
Cat. No. 1662 1670 1662 1670 1662 1670 1662 1670 1662 1670 1662 1670
+
Filter cards for 1662
Cat. No. 1675 (200 pcs.) 1675 (200 pcs.) 1675 (200 pcs.) 1676 (100 pcs.) 1677 (100 pcs.) 1678 (100 pcs.)
+
Filter cards for 1670
Cat. No. 1692 (200 pcs.) 1692 (200 pcs.) 1692 (200 pcs.) 1691 (100 pcs.) 1694 (100 pcs.) 1693 (100 pcs.)
+
UNIVERSAL 320 / 320 R Bucket
max. RPM | max. RCF 4,000 min-1 | 1,467 lid inclusive
max. capacity 4 cyto chambers Cat. No. 1680
run-up | run-down, braked in sec 20 | 25
angle 90°
Cat. No. 1624
+
UNIVERSAL 320 / 320 R Bucket
max. RPM | max. RCF 5,000 min-1 | 1,842 lid inclusive
max. capacity 6 cyto chambers Cat. No. 1680
run-up | run-down, braked in sec 20 | 22
angle 90°
Cat. No. 1626
CYTO CHAMBERS
Cyto chambers
area in mm² 30 60 120
Ø in mm 6.2 8.7 12.4
Cat. No. 1671-100 (100 pcs.) 1672-100 (100 pcs.) 1673-100 (100 pcs.)
+
Filter cards
Cat. No. 1696 (100 pcs.) 1697 (100 pcs.) 1698 (100 pcs.)
182
ROLLING CABINETS
All rolling cabinets are of sturdy design and feature castors and two locks. Any vibrations of the centrifuge are safely
compensated for.
550 550
260 260
Low and narrow, Low and wide, High and narrow, High and wide,
with one drawer. with one drawer. with two drawers. with two drawers.
Depth 650 mm Depth 650 mm Depth 650 mm Depth 650 mm
Cat. No. 4612-A Cat. No. 4614-A Cat. No. 4613-A Cat. No. 4615-A
EQUIPMENT
HettLiner Compensatory weights (set) Balancing inserts* Loading aid
Blood bags can be secured in If blood bag carriers are not In case there are not enough Secure your samples and
inserts using HettLiners. After filled to the same weight, then blood bag systems to occupy avoid accidental spillage with
centrifuging, they can be re- compensatory weights can be every carrier of the rotor, the convenient Loading aid for
moved by their loops without used to make up the difference. empty carriers can be filled centrifuge inserts. The Hettich
disturbing the sediment. One set includes: with balancing inserts. Taring Loading aid allows users to
40 balancing weights, 2 g each; weights supplied with the confidently hold and manage
20 balancing weights, 5 g each; inserts may be used for fine their samples without the risk
10 balancing weights, 10 g each; balancing. of the inserts toppling over.
5 balancing weights, 20 g each; 4584-A for insert 4559-A
5 balancing weights, 40 g each 4587-A for insert 4592-B
Cat. No. 4564 Cat. No. 4566 4589-A for insert 4516-A Cat. No. 4509
183
INCUBATORS
Efficient use of valuable space
186
TECHNICAL DATA
187
HETTCUBE 200 / R | 400 / R | 600 / R | INCUBATORS
Cat. No.
Shelf (Set) | Made of stainless steel, with standard rails, max. load (kg): 50 60001
Shelf (HTS-Set) | Made of stainless steel, with telescopic rails, extendable up to 70 %, max. load (kg): 40 60031
Drawer (HTS-Set), High 30 mm | Made of stainless steel, with telescopic rails, extendable up to 70 %, tightly welded, max. load (kg): 40 60024
Drawer (HTS-Set), High 65 mm | Made of stainless steel, with telescopic rails, extendable up to 70 %, tightly welded, max. load (kg): 40 60025
Drawer (HTS-Set), High 105 mm | Made of stainless steel, with telescopic rails, extendable up to 70 %, tightly welded, max. load (kg): 40 60026
Rack (HTS-Set) | For Petri dishes, stainless steel, with telescopic rails, extendable up to 70 %, Petri dishes Ø (mm): 90, max. load (pcs): 90 60038
Rack (Set) | For Petri dishes, stainless steel, with standard rails, Petri dishes Ø (mm): 90, max. load (pcs): 90 60039
Rack | For Petri dishes, stainless steel, Petri dishes Ø (mm): 90, max. load (pcs): 90 60040
Rack (HTS-Set) | For inclined storage of cultures (Loewenstein), stainless steel, with telescopic rails, extendable up to 70 %,
60036
inclination angle: 5°, tube Ø (mm): 15-20, max. load (pcs): 81tube
Rack (Set) | For inclined storage of cultures (Loewenstein), stainless steel, with standard rails, inclination angle: 5°, tube Ø (mm):
60037
15-20, max. load (pcs): 81 tubes
Rack | For inclined storage of cultures (Loewenstein), stainless steel, inclination angle: 5°, tube Ø (mm): 15-20, max. load (pcs): 81 tubes 60041
Frame L, 16-place | Made of stainless steel, for inclined storage of cultures, tube Ø (mm): 15-20, Tube length (mm): 100-125,
60027
inclination angle 5° or 20 °
Frame XL, 16-place | Made of stainless steel, for inclined storage of cultures, tube Ø (mm): 15-20, Tube length (mm): 126-170,
60028
inclination angle 5° or 20 °
Switchboard | 4-fold socket strip, as a unit controllable via display, on the back of the device 60521
Independent PT 100 sensor | For independent temperature measurement, four-wire system, temperature values output with ana-
60503
logue output 4-20 mA on the back of the device
Passive dehumidification | For individual or timed opening of a dehumidification module via the touchscreen 60042
Service: Assembly of the Stacking kit for the HettCube 200 | 200 R 60043
Service: Changing the door hinge 60044
Glass door | All-glass outer door, for HettCube 200 | 200 R 60030
Glass door | All-glass outer door, for HettCube 400 | 400 R 60029
Glass door | All-glass outer door, for HettCube 600 | 600 R 60013
Access port | Ø (mm): 22, Foam stoppers 60006
Access port | Ø (mm): 42, Foam stoppers 60007
Access port | Ø (mm): 67, Foam stoppers 60008
Stacking kit | For safe stacking of two HettCubes 200 | 200 R 60009
Rolling cabinet | Lockable, with one drawer, incl. lockable castors, WxDxH (mm): 770x800x550, for HettCube 200 | 200 R 60010
USB Port Lock (Set) | For securing the USB-A interface. Set consisting of 10 securing clips and 1 USB key tool. 60525
Parameter for continuous cooling operation | For storing samples below 15 °C for more than 2 weeks 60526
188
EXTENSIVE STANDARD EQUIPMENT
4.3 inch touchscreen Shelf (HTS-Set) with telescopic Access port on rear panel
rails Ø 42 mm
* Choose other shelves / drawers as standard, we credit you the price of unused standard inserts.
189
HETTCUBE 200 / R | 400 / R | 600 / R | INCUBATORS
190
SAFETY FOR YOUR SAMPLES
FLEXIBLE SETTINGS
Various events and alarm functions are individually adjustable. For example: Devia-
tions from the interior temperature can be limited individually over tolerance range
limits or fixed via independent temperature safety device of Classes 3.1 and 3.2.
Class 3.2 is already included in the standard version of all refrigerated HettCubes.
PERFECT CONDITIONS
INCUBATORS
191
HETTCUBE 200 / R | 400 / R | 600 / R | INCUBATORS
Due to their gentle air flow and edge-to-edge temperature uniformity, HettCube
incubators provide up to 30 % more validated usable space* than a traditional
incubator with the same internal volume.
*in accordance with DIN 12880:2007-05
50 % SMALLER FOOTPRINT
Conventional incubators
360 liters of validated usable space
192
HEAT COMPENSATION
HettCube models react to changes in ambient Heat compensation of the HettCube 200 R / 400 R / 600 R
conditions. Temperature fluctuations outside Lowest attainable temperature values upon introduction of equipment
with different heat outputs.
the incubator and energy introduced into the
usable space by external equipment are com-
45
pensated for immediately and actively.
Temperature in °C
40
35
30
25
20
Temperature HettCube
200 R (0 °C to +65 °C) 15
Temperature HettCube
400 R (0 °C to +65 °C) 10
Temperature HettCube
600 R (0 °C to +65 °C) 5
5HODWLYHKXPLGLW\LQVLGH>@
&RQGHQVDWLRQIUHH &RQGHQVDWLRQIUHH
]RQH
]RQH
INCUBATORS
7HPSHUDWXUH 7HPSHUDWXUH
LQVLGHDPELHQW LQVLGH!DPELHQW
,QWHUQDOWHPSHUDWXUH>&@
&RQGHQVDWLRQSRVVLEOHLQWKHERXQGDU\DUHDV
193
HETTCUBE 200 / R | 400 / R | 600 / R | INCUBATORS
*Assuming 24h operation 365 days a year. The basis for calculation is € 0.29 per kWh/h – the average
price of electricity in Germany in 2018 and 0.6 kg CO2 per kWh/h.
First-class isolation
The advanced control system and insulation mean that the incubator will maintain
a set temperature even if there is only a difference of 1 K (°C) from the ambient
temperature. This allows an uncooled HettCube incubator to be used in situations
in which a comparable incubator would require cooling.
PROVEN QUALITY
Certifications
Hettich products comply with all applicable safety regulations, carry the TÜV seal
and are compliant with IVD. Hettich manufactures according to the applicable
quality and environmental management systems, including ISO 9001, ISO 13485
and ISO 14001.
194
PRODUCT VIDEOS
Would you like to learn more about this product? Scan the QR Code to visit
our YouTube channel:
www.youtube.com/hettichlabtechnology
INCUBATORS
195
ENVIRONMENTAL
PRODUCTS
Testing for Food, Agro, Pharma & Life Science
Are you looking for climate control equipment? We are specialized in the design,
manufacture, installation and maintenance of such equipment. Hettich delivers
standard equipment which can be adapted to your application. The product
range includes all forms of simulation with the ability to control such variables as
temperature, humidity and light.
CONTROL PANELS
The control panels from Hettich are easy to operate and specifically tailored to users’ needs. Entry of the parameters is fast,
precise and convenient by way of an adjuster knob and / or selector keys on a foil keypad. The intuitive display shows the
actual values in digital format while the centrifuge is running.
EBA 270
The models EBA 200, EBA 200 S, Centrifuge models EBA 280 and EBA
HAEMATOKRIT 200 and MIKRO 185 280 S are equipped with the M control
are operated with the E Plus control panel. The parameters are selected
panel. In contrast to the E control panel with the Select key and the desired
ROTOFIX 32 A this allows entry of the speed (RPM) or values are set using arrow keys and
the relative centrifugal force (RCF). stored by pressing the Start/Pulse key.
The E(conomy) control panel is fitted
DISPLAY DISPLAY
in the EBA 270 and ROTOFIX 32 A
PROG Program number. Ten programmable
models. The required centrifugation RCF Relative centrifugal force.
memories are available.
RPM Speed indication. Entry in increments
parameters can be entered quickly and >RCF< Relative centrifugal force.
of 10.
easily on the user-friendly keypad: RPM Speed indication. Entry in increments of 10.
t/min:s Centrifugation time (max. 99 min : 59 sec).
t/min:s Centrifugation time (max. 99 min : 59 sec).
DISPLAY KEYPAD
KEYPAD
RPM Speed indication. Entry in increments of
100. Increases the relevant value. PROG Selects the program menu to call up or
t Time indication. Entry in minutes. Decreases the relevant value. store programs.
max. 99 min. RCF Switches from RPM to RCF display. Entry RCF Switches from RPM to RCF display. Entry
of the RCF in increments of 1. Input of of the RCF in increments of 1. Entry of the
KEYPAD rotor radius in mm in RCF mode. centrifuging radius in mm.
SELECT Guides the user through the menu SELECT Guides the user through the menu
Increases the relevant value.
options. options.
Decreases the relevant value.
PULSE For short centrifugation steps. START Starts centrifugation. Increases the relevant value.
OPEN Opens the lid (EBA 270). PULSE For short centrifugation steps. Decreases the relevant value.
START Starts centrifugation. STOP Stops centrifugation manually. START Starts centrifugation.
STOP Stops centrifugation manually OPEN Opens the lid at standstill. PULSE For short centrifugation steps.
RCF Switches from RPM to RCF display STOP Stops centrifugation manually.
(ROTOFIX 32 A). OPEN Opens the lid at standstill.
198
N PLUS CONTROL PANEL C CONTROL PANEL S CONTROL PANEL
The MIKRO 200 / 200 R. MIKRO 220 The advanced C control panel signifi- This special-class control panel is
/ 220 R. UNIVERSAL 320 / 320 R and cantly facilitates the daily laboratory rou- standard with the ROTIXA 500 RS and
ROTOFIX 46 / 46 H models are quick tine. Parameter selection is done via the ROTO SILENTA 630 RS floorstanding
and easy to operate using this variant use of symbol keys. Values are set with centrifuges.
of the N control panel. The parameters the control knob. and recorded by pres-
DISPLAY
are selected with the Select key. An sing the Start key. The temperature in the
PROG-Nr Program number.
adjuster knob is used to set the values. refrigerated ROTINA 380 R. ROTINA 420
89 programmable memories are available.
and the settings are stored by pressing R, ROTANTA 460 R and ROTANTA 460 T/°C Temperature.
the Start/Impulse key. Robotic centrifuges can be set in either PROFIL Run-up and run-down profile.
n/min-1 Speed indication.
Celsius (°C) or Fahrenheit (°F) degrees. t/min:sec Centrifugation time (max. 999 min: 59 sec).
199
CAPACITY
Commonly-used tubes
at a glance
W x D x H in mm
13 x 16 x
Ø x L in mm 6 -11 x 38 - 11 x 36 17 x 100 34 x 100 40 x 115 65 x 115 17 x 120
75 / 100 75 / 100
MANUAL CENTRIFUGE - - - 4 - - - 4 4 4
EBA 270 - - 6 6 - - - 6 6 -
MIKRO 185 24 - 12 - - - - - - -
MIKRO 200 | 200 R 30 - 15 - - - - - - -
ROTOFIX 46 - - - 48 8 4 4 - - 28
ROTOLAVIT II - - - 24 x 5 ml - - - - - -
200
50 250 / 500 250 / 290 650 / 750 1,000 2,000 MTP 500 - - Maximum performance
of the centrifuges
150 x 100 128 x 15
x 180 x 86
29 x 60 x 162 / 61 x 122 / 97 x
96 x 176 4-place - -
115 / 115 96 x 147 62 x 137 139 / 152
max. RPM
Maximum number of tubes per centrifuge max. RCF min-1
- - - - - - - - - - 1,298 3,000
- - - - - - - - - - 3,461 | 6,153 6,000 | 8,000
- - - - - - - - - - 2,254 4,000
- - - - - - - - - - 18,845 14,000
- - - - - - - - - - 21,382 15,000
8 - - - - - - - 6 12 4,226 6,000
16 - 4 - - - 12 - 8 - 24,400 15,000
8 - 4 - - - - - - - 3,095 4,000
40 4 6 4 4 - 24 4 12 - 18,038 11,500
- - - - - - - - - - 18,516 13,000
- - - - - - - - - - 1,438 3,500
OVERVIEWS
201
FEATURES
powered lid-locking
twist lock
EBA 200 | 200 S metal lid
EBA 270
HAEMATOKRIT 200
MIKRO 185
MIKRO 200
MIKRO 200 R
MIKRO 220
MIKRO 220 R
ROTOFIX 32 A
UNIVERSAL 320
UNIVERSAL 320 R
ROTINA 380
ROTINA 380 R
ROTINA 420
ROTINA 420 R
ROTOFIX 46
ROTOFIX 46 H
ROTIXA 500 RS
ROTOLAVIT II
Robotic centrifuges Details on our models MIKRO 220 Robotic, ROTINA 380, 380 R, 380 RC Robotic and ROTANTA 460 Robotic
202
also available in 115 V / 60 Hz
automatic rotor recognition
imbalance switch-off
heating (to +90 °C)
brushless drive
control panel
error display
air cooling
E EBA 270
E ROTOFIX 32 A
C ROTINA 380
C ROTINA 380 R
C ROTINA 420
C ROTINA 420 R
N plus ROTOFIX 46
S ROTIXA 500 RS
Touch ROTOLAVIT II
203
AVAILABLE TUBES
204
AVAILABLE TUBES
OVERVIEWS
205
CERTIFICATES / REGISTRATIONS
CERTIFICATES / REGISTRATIONS
Hettich centrifuges and incubators fulfill all applicable European directives that apply to you. Every work step is subject to
strict controls and documentation. The company is ISO 9001, ISO 13485 and ISO 14001 certified. Hettich products
are manufactured with care and responsibility, giving them a worldwide reputation for safety and reliability.
PRODUCT REGISTRATIONS
EBA 270
HAEMATOKRIT 200
MIKRO 185
ROTOFIX 32 A
ROTOFIX 46 | 46 H
ROTIXA 500 RS
ROTOLAVIT II
206
COMPANY CERTIFICATIONS
ISO 9001 ISO 14001 EN ISO 13485
Quality management system Environmental management system Quality management system
according to ISO 9001 according to ISO 14001 according to ISO 13485
PRODUCT CERTIFICATIONS
TÜV SÜD certification mark Factory certificate HettCert Authorized Economic Operator »Made in Germany«
Tested device safety in accordance Device calibration with the high require- We are able to offer expedited All Hettich products are designed,
with the high technical requirements in ments of Hettich according to ISO 9001 shipments and customs clearance. developed and produced in Germany
Europe, U.S.A. and Canada and ISO 13485
207
CATALOG EXPLANATION
CATALOG EXPLANATION
Layout
1.
1. Navigation:
Header + sheet index 2.
2. Rotor 3.
+ Bucket
1.
+ Lid
+ Adapter
+ Vessel
+ Thumbnail 4.
3. All specifications apply to the
possible combinations shown
Shortcuts
Vessels: Device name:
CP = Culture Plate C = C after the model name stands for underbench centrifuge
DWP = Deep Well Platte F = F after the model name stands for floorstanding centrifuge
MS = Micronic System H = H after the model name stands for heated centrifuge
MTP = Microtitre Plate R = R after the model name stands for refrigerated centrifuge
QP = Filter Plate S = S after the model name stands for S control panel in the centrifuge.
PA = Polyamide (Except EBA 200 S, EBA 280 S).
PC = Polycarbonate
PE = Polyethylene
PP = Polypropylene
Angle rotor | Angle rotors are ideally suited for use at high speeds. Time can be saved by tilting the tubes and acceler-
ating the separation.
Calculation of centrifugal force | RCF = (n/1000)² x r x 1,118 | n = Rotation in min-1 (RPM) | r = Radius in mm
Capacity of the centrifuge | An overview of all capacities can be found on page 200.
Disk Rotor | This type of angle rotor was specially developed for the centrifugation of capillaries. Significant results
are generated in the 90° angle and can be displayed directly in the rotor. With the help of an evaluation cover the
results can be read easily and safely.
Download Center | The Download Center on our website allows you to access the most up to date documents including
catalogs, brochures, data sheets and certificates. Please visit: www.hettichlab.com/downloadcenter
208
Drum rotor | A extended form of the angle rotor is the drum rotor. With high rotational speed and high capacity, it is
the ideal choice to create sediment at the bottom of the vessel.
Environment | As an ISO 14001 certified company, sustainability and the protection of the environment are a foundation of
our principles. Find out more on our website: www.hettichlab.com
Footnotes | All footnotes in the catalog can be found on the last page. The fold-out page allows you to always see the
appropriate footnote.
Hettich Packages | No more searching for the right combination of accessories. Our packages include centrifuge, rotor,
buckets and adapters – suitable for your specific application.
Model variants | Many of our devices have two different model variants, e.g. cooled and uncooled. In order to be able to
distinguish between these two, we use a vertical hyphen (Model x | Model y)
For special requirements you can find further versions of our centrifuges on page 204.
RCF | The relative centrifugal force RCF (or often called g-value) is a characteristic value for centrifugation.
Registrations | Find a detailed overview of all registrations of our products on page 206.
RPM | Is the measurement unit for the speed. It indicates the number of rotations of the rotor in a period of one minute.
Swing-out rotor | During centrifugation, the tubes are spin at a 90° horizontal angle. In the process, the sediment
is deposited at the bottom of the tube, separations are formed horizontally. If higher capacities are required in
the mid speed range, swing-out rotors are used. The wide variety of accessories is an additional feature of these rotors.
Symbol
Reaction tubes Blood collection
Plates, filter plates Special tubes
up to 5 ml tubes, urine tubes
Tubes with
PCR strips Racks Hematocrit capillaries
screw cap
IMPRINT
01.21 | We reserve the right to make technical changes to our products as well as printing errors and colour
deviations in our printed matters we reserve ourselves.
Conception: dn.p Marketing + Werbeagentur GmbH, Wittingen | Photography: Jürgen Weisheitinger, Lörrach / Tom Pingel,
Hamburg u. Stuttgart | Illustrations: Grafikbüro Christian Islinger, Regensburg | Printing: Typodruck GmbH & Co. KG,
OVERVIEWS
209
HETTICH QUALITY WORLDWIDE
SINGAPORE USA
Hettich Hettich Instruments LP
Asia Pacific Pte. Ltd. 100 Cummings Center, Ste 136L
3 Ang Mo Kio Street 62, Beverly, MA 01915
#01-47 LINK@AMK Phone +1 (0)978 / 2 32 39 57
Singapore 569139 Fax +1 (0)978 / 2 32 39 58
Phone +65 6358 3833 [email protected]
Fax +65 6358 3558 www.hettweb.com
[email protected]