Micro Data Center Solution

Foundation of Digital Future

Simplifying and protecting your digital system with this pre-


manufactured, self-contained and readily scalable micro data
center solution.

Customize with Expert


The Edge Wave

1990S 2000S 2010S 2020S 2030S


Attom Technology is dedicated to design and deliver the Micro Modular Data Center
Product Platform, with the No.1 Flexible and Versatile options, to simplify Edge Data
Centers deployment and management.

1964 1983 1998 2006 2015

>> Are you ready to catch the coming


edge era wave?

Customize with Expert


Micro Data Center for Edge Computing

Edge Data Center plays key roles in the next wave of edge computing
development, with the functions of reducing latency, improving safety, and
saving network cost.

Edge Data Center is suitable for diverse applications and sites from enterprise,
telecom, to edge colocation industries.

Enterprise
Edge
Mobile
Edge
Computing Cord
Access CDN
Colocation

Device On-Premise Network Access Ramp to Cloud Cloud


▪ Smart Sensors ▪ Enterprise IT ▪ Fixed ▪ Colocation ▪ Public
▪ Smart Machines ▪ Private Cloud ▪ Mobile ▪ CDN ▪ Hybrid

Edge Cloud
Devices Edge Data Centers Data
Center
s

Customize with Expert


Micro Data Center Applications

Private Cloud
IIoT & Edge AI & Deep
& Hybrid
Computing Learning
Cloud

SMB & Office


√ √ √
Telecom & ISP
√ √ √
Banks &
Financial √ √ √
Retail &
Logistic √ √ √
Smart
Manufacturing √ √ √
Military, Energy
& Mining √ √ √
Medical &
Education √ √ √

Customize with Expert


Attom Micro Data Center Platform

AgileRakTM
Indoor Micro Data Center
Fully integrated with indoor type rack, UPS
power, battery, cooling, monitoring, security, and
fire systems.

Available from half rack to multiple racks.


Customization is acceptable.

AgileHubTM
Outdoor Micro Data Center
Fully integrated with outdoor type cabinet,
UPS/DC power, battery, cooling, monitoring,
security, and fire systems.

Available with 1 to 3 cabinets all in one solution.


Customization is acceptable.

AgileCubTM
Container Micro Data Center
Fully integrated with ISO container, cabinet,
UPS/DC power, battery, cooling, monitoring,
security, and fire systems.

Available with 10f, 20f and 40f all in one solution.


Customization is acceptable.

Customize with Expert


Attom Micro Data Center Benefits

An easy flexible, expandable, intelligent micro data center product is one of the keys to
the edge computing success.

With all these in mind , we create this Attom Micro Modular Data Center products
platform.

It‘s a plug and play, totally enclosed and fully integrated solution built in with rack,
power & battery, cooling, monitoring and security systems.

Easy Easy Easy


Deployment Management Expansion

Pre-manufactured Design once and A stand alone full


and fully tested deploy anywhere. By function solution. You
means that no on- this standardized can plan and invest
site engineering architecture and your IT assets step
needed to activate remote monitoring by step while your
the product. Within access platform, you business grows. Buy
one day, you can can gain control of small and scale to big.
deploy the IT these critical assets, Invest only when
equipments and reduce risks and necessary.
quickly power on operational costs,
your business. and improving
service levels.

Customize with Expert


AgileRakTM Series

MDC with Top Package MDC with Row Package MDC with Rack Split MDC with Row Split Cooling
Cooling Cooling Cooling
3k – 6k MDC fully integrated with 5k – 10k MDC fully integrated 3k – 10k MDC fully integrated 6k – 20k MDC fully integrated
closed rack, package cooling, with closed rack, package with closed rack, split cooling, with closed rack, split cooling,
UPS, battery, power distribution, cooling, UPS, battery, power UPS, battery, power distribution, UPS, battery, power distribution,
security, monitoring and fire distribution, security, monitoring security, monitoring and fire security, monitoring and fire
systems. and fire systems. systems. systems.
No complex piping of remote No complex piping of remote Modular rack cooling flexible for Row cooling seamless integration
condenser installation. condenser installation. rack oriented MDC plan, with rack row and capacity
expansion and deployment. expansion.

Key Characteristics
- Rack-level cooling, cold and hot aisle isolation, - Cabinets, power distribution and cooling units
high efficiency, the PUE values as low as 1.3 have a variety of forms and specifications for
flexible application
- Plug and play design, available online in 10
minutes at the fastest - The front and rear doors of the cabinet are
equipped with a 3-in-1 access control system
- Fully enclosed design, dust and noise reduction,
protection level up to IP55 - Standard 10-inch integrated touch monitor
screen, the monitoring system does not take up
- Cabinet covered with insulation material to
U space of the cabinet
prevent condensation
- Support remote web, APP and centralized
- The cabinet is equipped with an emergency
monitoring, support monitoring protocols such
pop-up door system as standard, which can
as Modbus-TCP, SNMPV1 / V2, BACnet
automatically open the front and rear doors in
the event of a high temperature or fire alarm - Support global customized services

Customize with Expert


AgileRakTM Series

All in one design supports batch distributed rapid deployment, With multiple
configurations to suit a variety
Monitoring System Coolingof application scenarios.
System Fire System Server Rack
All in one monitoring host 1.5kW – 21.2kW Gas extinguishing Fully insulated
collects, displays and precision cooling in rack system triggered by standard 19 inch rack
reports system status, mount, top mount and smoke and system.
locally and remotely. row mount type. temperature

Security System Power Distribution UPS System Battery System


3 in 1 access control Rack mount power 3– 20kVA rack mount Optional lead-acid
system(Pin/Fingerprint/R distribution, metering, and UPS system protect batteries and lithium-ion
FID) and video management for all the power continuity. batteries (Rack-mount)
monitoring system. power lines.

Customize with Expert


AgileRakTM Series

Technical Data – AgileRak Indoor Micro Data Center – IEC Power Type
Product Model ATM-03N ATM-03W ATM-06E ATM-06T ATM-06F ATM-06K ATM-10S ATM-10G

Available Space for IT -U 18U 19U 26U 29U 35U 35U 35U 35U

Available Power for IT -kW 2.0 2.4 3.0 3.5 5.0 5.0 7.0 7.0

Redundancy N N N N N N N N

Width -mm 600 600 600 600 900 900 900 900

Depth -mm 1100 1100 1100 1100 1400 1400 1400 1400

Height -mm 1200 1590 2000 2000 2000 2000 2000 2000

Weight -kg 162 190 330 374 521 521 525 525

IP Level IP5X IP5X IP5X IP5X IP5X IP5X IP5X IP5X

Input Power 220-240V/1P/50Hz 220-240V/1P/50Hz 220-240V/1P/50Hz 220-240V/1P/50Hz 220-240V/1P/50Hz 220-240V/1P/50Hz 220-240V/1P/50Hz 220-240V/1P/50Hz

Recommended Breaker 16A 32A 63A 63A 63A 63A 63A 63A

Power Section

UPS -kVA 3.0 3.0 6.0 6.0 6.0 6.0 10.0 10.0

UPS Type Rack Rack Rack Rack Rack Rack Rack Rack

Standard Battery 12V/9AH 6Pcs 12V/9AH 6Pcs 12V/9AH 16Pcs 12V/9AH 16Pcs 12V/9AH 16Pcs 12V/9AH 16Pcs 12V/9AH 16Pcs 12V/9AH 16Pcs

PDU Basic 8 Slots Basic 8 Slots Basic 16 Slots Basic 16 Slots Basic 16 Slots Basic 16 Slots Basic 16 Slots Basic 16 Slots

Cooling Section

Cooling Type Fan Ventilation Packaged DX Packaged DX Split DX Split DX Packaged DX Split DX Packaged DX

Mount Type Top Top Top Rack Row Row Row Row

Capacity-kW 2.0 3.5 3.5 3.9 5.6 5.6 7.6 7.6

Emergency Ventilation √ √ √ √ √ √ √ √

DCIM Section

Local Display Touch Screen Touch Screen Touch Screen Touch Screen Touch Screen Touch Screen Touch Screen Touch Screen

Remote Access Web Access Web Access Web Access Web Access Web Access Web Access Web Access Web Access

Reporting Protocol Modbus-TCP Modbus-TCP Modbus-TCP Modbus-TCP Modbus-TCP Modbus-TCP Modbus-TCP Modbus-TCP

UPS Mgmt. Yes Yes Yes Yes Yes Yes Yes Yes

Cooling Mgmt. Yes Yes Yes Yes Yes Yes Yes Yes

Temperature Humidity Sensor Yes Yes Yes Yes Yes Yes Yes Yes

Fire Sensor Smoke Smoke Smoke Smoke Smoke Smoke Smoke Smoke

Water Sensor Yes Yes Yes Yes Yes Yes Yes Yes

Door Sensor Front/Rear Front/Rear Front/Rear Front/Rear Front/Rear Front/Rear Front/Rear Front/Rear

Security Section

Access Control RFID/Finger/PIN RFID/Finger/PIN RFID/Finger/PIN RFID/Finger/PIN RFID/Finger/PIN RFID/Finger/PIN RFID/Finger/PIN RFID/Finger/PIN

Video Surveillance Optional Optional Optional Optional Optional Optional Optional Optional

Fire Fighting Section


FM200 Rack FM200 Rack FM200 Rack FM200 Rack FM200 Rack FM200 Rack FM200 Rack FM200 Rack
Fire Extinguisher
Module (Opt.) Module (Opt.) Module (Opt.) Module (Opt.) Module (Opt.) Module (Opt.) Module (Opt.) Module (Opt.)

Early Detection Vesda (Opt.) Vesda (Opt.) Vesda (Opt.) Vesda (Opt.) Vesda (Opt.) Vesda (Opt.) Vesda (Opt.) Vesda (Opt.)

Customize with Expert


AgileRakTM Series

Technical Data – AgileRak Indoor Micro Data Center – US Power Type


Product Model ATM-03N ATM-03W ATM-06E ATM-06T ATM-06F ATM-06K ATM-10S ATM-10G

Available Space for IT -U 18U 18U 25U 28U 34U 34U 32U 32U

Available Power for IT -kW 2.0 2.4 3.0 3.5 5.0 5.0 7.0 7.0

Redundancy N N N N N N N N

Width -mm 600 600 600 600 900 900 900 900

Depth -mm 1100 1100 1100 1100 1400 1400 1400 1400

Height -mm 1200 1590 2000 2000 2000 2000 2000 2000

Weight -kg 162 190 330 374 521 521 525 525

IP Level IP5X IP5X IP5X IP5X IP5X IP5X IP5X IP5X

Input Power 110-120V/1P/60Hz 208-240V/2P/60Hz 208-240V/2P/60Hz 208-240V/2P/60Hz 208-240V/2P/60Hz 208-240V/2P/60Hz 208-240V/2P/60Hz 208-240V/2P/60Hz

Recommended Breaker 16A 32A 63A 63A 63A 63A 63A 63A

Power Section

UPS -kVA 3.0 6.0 6.0 6.0 6.0 6.0 10.0 10.0

UPS Type Rack Rack Rack Rack Rack Rack Rack Rack

Standard Battery 12V/9AH 6Pcs 12V/9AH 16Pcs 12V/9AH 16Pcs 12V/9AH 16Pcs 12V/9AH 16Pcs 12V/9AH 16Pcs 12V/9AH 16Pcs 12V/9AH 16Pcs

PDU Basic 8 Slots Basic 8 Slots Basic 16 Slots Basic 16 Slots Basic 16 Slots Basic 16 Slots Basic 16 Slots Basic 16 Slots

Cooling Section

Cooling Type Fan Ventilation Packaged DX Packaged DX Split DX Split DX Packaged DX Split DX Packaged DX

Mount Type Top Top Top Rack Row Row Row Row

Capacity-kW 2.0 3.5 3.5 3.9 5.6 5.6 7.6 7.6

Emergency Ventilation √ √ √ √ √ √ √ √

DCIM Section

Local Display Touch Screen Touch Screen Touch Screen Touch Screen Touch Screen Touch Screen Touch Screen Touch Screen

Remote Access Web Access Web Access Web Access Web Access Web Access Web Access Web Access Web Access

Reporting Protocol Modbus-TCP Modbus-TCP Modbus-TCP Modbus-TCP Modbus-TCP Modbus-TCP Modbus-TCP Modbus-TCP

UPS Mgmt. Yes Yes Yes Yes Yes Yes Yes Yes

Cooling Mgmt. Yes Yes Yes Yes Yes Yes Yes Yes

Temperature Humidity Sensor Yes Yes Yes Yes Yes Yes Yes Yes

Fire Sensor Smoke Smoke Smoke Smoke Smoke Smoke Smoke Smoke

Water Sensor Yes Yes Yes Yes Yes Yes Yes Yes

Door Sensor Front/Rear Front/Rear Front/Rear Front/Rear Front/Rear Front/Rear Front/Rear Front/Rear

Security Section

Access Control RFID/Finger/PIN RFID/Finger/PIN RFID/Finger/PIN RFID/Finger/PIN RFID/Finger/PIN RFID/Finger/PIN RFID/Finger/PIN RFID/Finger/PIN

Video Surveillance Optional Optional Optional Optional Optional Optional Optional Optional

Fire Fighting Section


FM200 Rack FM200 Rack FM200 Rack FM200 Rack FM200 Rack FM200 Rack FM200 Rack FM200 Rack
Fire Extinguisher
Module (Opt.) Module (Opt.) Module (Opt.) Module (Opt.) Module (Opt.) Module (Opt.) Module (Opt.) Module (Opt.)

Early Detection Vesda (Opt.) Vesda (Opt.) Vesda (Opt.) Vesda (Opt.) Vesda (Opt.) Vesda (Opt.) Vesda (Opt.) Vesda (Opt.)

Customize with Expert


AgileRowTM Series

Closed Aisle System Monitoring System Security System


Independent cold / hot closed All in one monitoring host 3 in 1 access control
aisle are integrated at the front collects, displays and reports system(Pin/Fingerprint/RFID)
and rear of the cabinet, system status, locally and and video monitoring system.
respectively. remotely.

Power Distribution Power System Cooling System Server Rack


Rack mount power 48VDC power, or 3kVA – 2.5kW – 90kW rack / row Standard 19-inch server
distribution, metering, and 200kVA rack mount or mount precision cooling, cabinet, glass front door,
management for all the modular UPS system seamlessly matched to sheet metal back door
power lines. protect power continuity. the rack.

Customize with Expert


AgileRowTM Series

Technical Data – AgileRow Indoor Micro Data Center – IEC Power Type
Product Model Configure to Order

Available Space for IT -U <= 10 * 42U

Available Power for IT -kW <= 15kW/Rack

Redundancy N / N+1 / 2N

Width -mm Per Definition

Depth -mm 1400

Height -mm 2000

Weight -kg Per Definition

IP Level IP5X / IP55(Opt.)

Input Power 220-240V/1P/50-60Hz or 380-415V/3P/50-60Hz

Recommended Breaker Per Definition

Power Section

UPS -kVA 3kVA - 200kVA

UPS Type Rack / Modular

Standard Battery <= 4hours backup time

PDU Basic / Smart(Opt.)

Cooling Section

Cooling Type Packaged DX / Split DX / Chilled Water

Mount Type Row / Rack / Top

Capacity-kW 3.9-90kW

Emergency Ventilation √

DCIM Section

Local Display Touch Screen

Remote Access Web Access / Email / SMS(Opt.)

Reporting Protocol Modbus-TCP / SNMP(Opt.)

UPS Mgmt. Yes

Cooling Mgmt. Yes

Temperature Humidity Sensor Yes

Fire Sensor Smoke

Water Sensor Yes

Door Sensor Front / Rear

Security Section

Access Control RFID / Finger / PIN

Video Surveillance Optional

Fire Fighting Section

Fire Extinguisher FM200 Rack Module (Opt.)

Early Detection Vesda (Opt.)

Customize with Expert


AgileRowTM Series

Technical Data – AgileRow Indoor Micro Data Center – US Power Type


Product Model Configure to Order

Available Space for IT -U <= 10 * 42U

Available Power for IT -kW <= 15kW/Rack

Redundancy N / N+1 / 2N

Width -mm Per Definition

Depth -mm 1400

Height -mm 2000

Weight -kg Per Definition

IP Level IP5X / IP55(Opt.)

Input Power 208-240V/2P/60Hz or 200-230V/3P/50-60Hz

Recommended Breaker Per Definition

Power Section

UPS -kVA 3kVA - 200kVA

UPS Type Rack / Modular

Standard Battery <= 4hours backup time

PDU Basic / Smart(Opt.)

Cooling Section

Cooling Type Packaged DX / Split DX / Chilled Water

Mount Type Row / Rack / Top

Capacity-kW 3.9-90kW

Emergency Ventilation √

DCIM Section

Local Display Touch Screen

Remote Access Web Access / Email / SMS(Opt.)

Reporting Protocol Modbus-TCP / SNMP(Opt.)

UPS Mgmt. Yes

Cooling Mgmt. Yes

Temperature Humidity Sensor Yes

Fire Sensor Smoke

Water Sensor Yes

Door Sensor Front / Rear

Security Section

Access Control RFID / Finger / PIN

Video Surveillance Optional

Fire Fighting Section

Fire Extinguisher FM200 Rack Module (Opt.)

Early Detection Vesda (Opt.)

Customize with Expert


AgileCubTM Series

Attom container type Micro Data Center designed and engineered with
standard container size of all in one design helps IT professionals deploy data
center quickly and easily.

Fire System Cooling System Monitoring System


Fire extinguisher and 2.5kW – 40kW precision All in one monitoring host
early detection system. cooling in rack mount, top collects, displays and reports
mount and row mount type. system status, locally and
remotely.

Power
Distribution
Rack mount power
distribution, metering,
and management for
all the power lines.

UPS System
3kVA – 200kVA rack
mount modular UPS
system protect power
continuity.

Security System Battery System Rack System


Optional lead-acid Standard 19-inch server cabinet,
3 in 1 access control
batteries and lithium- 75% front and rear mesh door
system(Pin/Fingerprint
ion batteries (Rack- through-hole ratio, static load up to
/RFID) and video
mount) 1800kg, various options available
monitoring system.

Customize with Expert


AgileCubTM Series

10F Container Data Center


All in one 10F Container MDC fully integrated
with standard rack, wall mount cooling,
AC/DC power, battery, power distribution,
security, monitoring and fire systems.
IP55 protection and thermal insulated for
outdoor deployment -35C ~ 55C ambient.

20F Container Data Center


All in one 20F Container MDC fully integrated
with standard rack, wall mount cooling,
AC/DC power, battery, power distribution,
security, monitoring and fire systems.
IP55 protection and thermal insulated for
outdoor deployment -35C ~ 55C ambient.

40F Container Data Center


All in one 40F Container MDC fully integrated
with standard rack, wall mount cooling,
AC/DC power, battery, power distribution,
security, monitoring and fire systems.
IP55 protection and thermal insulated for
global deployment -35C ~ 55C ambient.

Dual Container Data Center


Assembled from 2 or more containers,
integrated with standard rack, row mount
cooling, AC/DC power, battery, power
distribution, security, monitoring and fire
systems.
IP55 protection and thermal insulated for
global deployment -35C ~ 55C ambient.

Customize with Expert


AgileHubTM Series

Technical Data – AgileCub Containerized Micro Data Center – IEC Power Type
Product Model ATM-10-C03 ATM-20-C03 ATM-30-C08 ATM-60-C08 ATM-80C18 ATM-140-C18 ATM-160-C36 ATM-320-C36 Customized

IT Rack No. 2 2 6 6 16 14 32 30 Per Definition

Power Density -kW/Rack 5.0 10.0 5.0 10.0 5.0 10.0 5.0 10.0 Per Definition

Redundancy N+1 N+1 N+1 N+1 N+1 N+1 N+1 N+1 N/N+1/2N

Width -mm 2438 2438 2438 2438 2438 2438 4876 4876 Per Definition

Depth -mm 2991 2991 6058 6058 12192 12192 12192 12192 Per Definition

Height -mm 2896 2896 2896 2896 2896 2896 2896 2896 Per Definition

Weight -kg 4170 4400 8135 8755 16475 17845 32380 36000 Per Definition

IP Level IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55

380-415V/3P 380-415V/3P 380-415V/3P 380-415V/3P 380-415V/3P 380-415V/3P 380-415V/3P 380-415V/3P


Input Power /50-60Hz /50-60Hz /50-60Hz /50-60Hz /50-60Hz /50-60Hz /50-60Hz /50-60Hz
Per Definition

Power Section

UPS -kVA 2* 10 3* 10 3* 15 5* 15 5* 25 7* 25 8* 25 7* 50 3 – 500kVA

UPS Mount Type Rack Rack Rack-Modular Rack-Modular Rack-Modular Rack-Modular Rack-Modular Floor-Modular Rack/Floor

Standard UPS Battery 15min@10kW 15min@20kW 15min@30kW 15min@60kW 15min@80kW 15min@140kW 15min@160kW 15min@300kW <= 4 hour

AC PDU Smart/Basic PDU Smart/Basic PDU Smart/Basic PDU Smart/Basic PDU Smart/Basic PDU Smart/Basic PDU Smart/Basic PDU Smart/Basic PDU Per Definition

-48VDC -A Optional Optional Optional Optional Optional Optional Optional Optional 10 – 600A

Standard 48VDC Battery Optional Optional Optional Optional Optional Optional Optional Optional <= 4 hour

48VDC Power
Optional Optional Optional Optional Optional Optional Optional Optional Per Definition
Distribution
Cooling Section

Cooling Type Packaged DX Packaged DX Packaged DX Packaged DX Packaged DX Packaged DX Packaged DX Packaged DX Packaged/Split

Mount Type Wall Wall Wall Wall Wall Wall Wall Wall Row/Room/Wall

Capacity-kW 2* 12.5 2* 21.2 3* 17.5 4* 21.2 5* 21.2 8* 21.2 10* 21.2 18* 21.2 1.5 – 200.0kW

DCIM Section

Local Display Touch Screen Touch Screen Touch Screen Touch Screen Touch Screen Touch Screen Touch Screen Touch Screen Touch Screen

Remote Access Web Access Web Access Web Access Web Access Web Access Web Access Web Access Web Access Web Access

Reporting Protocol Modbus/SNMP Modbus/SNMP Modbus/SNMP Modbus/SNMP Modbus/SNMP Modbus/SNMP Modbus/SNMP Modbus/SNMP Modbus/SNMP

UPS Mgmt. Yes Yes Yes Yes Yes Yes Yes Yes Yes

Cooling Mgmt. Yes Yes Yes Yes Yes Yes Yes Yes Yes

Temperature Humidity
Yes Yes Yes Yes Yes Yes Yes Yes Yes
Sensor

Fire Sensor Smoke Smoke Smoke Smoke Smoke Smoke Smoke Smoke Smoke

Water Sensor Yes Yes Yes Yes Yes Yes Yes Yes Yes

Door Sensor Yes Yes Yes Yes Yes Yes Yes Yes Yes

Security Section

Access Control RFID/Pin/Finger RFID/Pin/Finger RFID/Pin/Finger RFID/Pin/Finger RFID/Pin/Finger RFID/Pin/Finger RFID/Pin/Finger RFID/Pin/Finger RFID/Pin/Finger

Video Surveillance Yes Yes Yes Yes Yes Yes Yes Yes Yes

Fire Fighting Section


FM200 / FM200 / FM200 / FM200 / FM200 / FM200 / FM200 / FM200 / FM200 /
Fire Extinguisher
Novec1230 Novec1230 Novec1230 Novec1230 Novec1230 Novec1230 Novec1230 Novec1230 Novec1230

Early Detection VESDA VESDA VESDA VESDA VESDA VESDA VESDA VESDA VESDA

Customize with Expert


AgileHubTM Series

Technical Data – AgileCub Containerized Micro Data Center – US Power Type


Product Model ATM-10-C03 ATM-20-C03 ATM-30-C08 ATM-60-C08 ATM-80C18 ATM-140-C18 ATM-160-C36 ATM-320-C36 Customized

IT Rack No. 2 2 6 6 16 14 32 30 Per Definition

Power Density -kW/Rack 5.0 10.0 5.0 10.0 5.0 9.0 5.0 9.0 Per Definition

Redundancy N+1 N+1 N+1 N+1 N+1 N+1 N+1 N+1 N/N+1/2N

Width -mm 2438 2438 2438 2438 2438 2438 4876 4876 Per Definition

Depth -mm 2991 2991 6058 6058 12192 12192 12192 12192 Per Definition

Height -mm 2896 2896 2896 2896 2896 2896 2896 2896 Per Definition

Weight -kg 4170 4400 8135 8755 16475 17845 32380 36000 Per Definition

IP Level IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55

200-230V/3P 200-230V/3P 200-230V/3P 200-230V/3P 200-230V/3P 200-230V/3P 200-230V/3P 200-230V/3P


Input Power /50-60Hz /50-60Hz /50-60Hz /50-60Hz /50-60Hz /50-60Hz /50-60Hz /50-60Hz
Per Definition

Power Section

UPS -kVA 2* 10 3* 10 4* 10 5* 15 7* 15 10* 15 14* 15 20* 15 3 – 500kVA

UPS Mount Type Rack Rack Rack-Modular Floor-Modular Floor-Modular Floor-Modular Floor-Modular Floor-Modular Rack/Floor

Standard UPS Battery 15min@10kW 15min@20kW 15min@30kW 15min@60kW 15min@80kW 15min@126kW 15min@160kW 15min@270kW <= 4 hour

AC PDU Smart/Basic PDU Smart/Basic PDU Smart/Basic PDU Smart/Basic PDU Smart/Basic PDU Smart/Basic PDU Smart/Basic PDU Smart/Basic PDU Per Definition

-48VDC -A Optional Optional Optional Optional Optional Optional Optional Optional 10 – 600A

Standard 48VDC Battery Optional Optional Optional Optional Optional Optional Optional Optional <= 4 hour

48VDC Power
Optional Optional Optional Optional Optional Optional Optional Optional Per Definition
Distribution
Cooling Section

Cooling Type Packaged DX Packaged DX Packaged DX Packaged DX Packaged DX Packaged DX Packaged DX Packaged DX Packaged/Split

Mount Type Wall Wall Wall Wall Wall Wall Wall Wall Row/Room/Wall

Capacity-kW 2* 12.5 2* 21.2 3* 17.5 4* 21.2 5* 21.2 8* 21.2 10* 21.2 18* 21.2 1.5 – 200.0kW

DCIM Section

Local Display Touch Screen Touch Screen Touch Screen Touch Screen Touch Screen Touch Screen Touch Screen Touch Screen Touch Screen

Remote Access Web Access Web Access Web Access Web Access Web Access Web Access Web Access Web Access Web Access

Reporting Protocol Modbus/SNMP Modbus/SNMP Modbus/SNMP Modbus/SNMP Modbus/SNMP Modbus/SNMP Modbus/SNMP Modbus/SNMP Modbus/SNMP

UPS Mgmt. Yes Yes Yes Yes Yes Yes Yes Yes Yes

Cooling Mgmt. Yes Yes Yes Yes Yes Yes Yes Yes Yes

Temperature Humidity
Yes Yes Yes Yes Yes Yes Yes Yes Yes
Sensor

Fire Sensor Smoke Smoke Smoke Smoke Smoke Smoke Smoke Smoke Smoke

Water Sensor Yes Yes Yes Yes Yes Yes Yes Yes Yes

Door Sensor Yes Yes Yes Yes Yes Yes Yes Yes Yes

Security Section

Access Control RFID/Pin/Finger RFID/Pin/Finger RFID/Pin/Finger RFID/Pin/Finger RFID/Pin/Finger RFID/Pin/Finger RFID/Pin/Finger RFID/Pin/Finger RFID/Pin/Finger

Video Surveillance Yes Yes Yes Yes Yes Yes Yes Yes Yes

Fire Fighting Section


FM200 / FM200 / FM200 / FM200 / FM200 / FM200 / FM200 / FM200 / FM200 /
Fire Extinguisher
Novec1230 Novec1230 Novec1230 Novec1230 Novec1230 Novec1230 Novec1230 Novec1230 Novec1230

Early Detection VESDA VESDA VESDA VESDA VESDA VESDA VESDA VESDA VESDA

Customize with Expert


AgileHubTM Series

AgileHub Micro Data Center developed with multiple configurations that fit into
diverse application scenario, all with prefabricated size supports predicted
management and quick deployment.

Monitoring System Fire System


All in one monitoring host collects, Gas fire extinguishing system
locally and remotely. triggered by smoke and
temperature

Condenser Rack System


System
Provide professional Fully insulated standard
protective space for 19 inch rack system.
outdoor condensers.

AC/DC Power
3k – 30kVA rack mount
Security System modular UPS/DC Power
system protect power
RFID access control continuity.
system and video
monitoring system.

Cooling System
3.9kW – 31.1kW precision
cooling powered by UPS in
rack mount, and row mount
type

Power Distribution Battery System


Rack mount power distribution, Optional lead-acid batteries and
metering, and management for all the lithium-ion batteries (Rack-mount)
power lines.

Customize with Expert


AgileHubTM Series

1-Rack MDC with Rack Cooling


MDC fully integrated with 1 rack space, rack
cooling, AC/DC power, battery, power
distribution, security, monitoring and fire
systems.

IP55 protection and thermal insulated for


outdoor deployment.

2-Rack MDC with Rack Cooling


MDC fully integrated with 2 rack space, rack
cooling, AC/DC power, battery, power
distribution, security, monitoring and fire
systems.

IP55 protection and thermal insulated for


outdoor deployment -35C ~ 45C ambient.

2-Rack MDC with Row Cooling


MDC fully integrated with 2 rack space, inrow
cooling, AC/DC power, battery, power
distribution, security, monitoring and fire
systems.

IP55 protection and thermal insulated for


outdoor deployment -35C ~ 45C ambient.

3-Rack MDC with Rack Cooling


MDC fully integrated with 3 rack space, rack
cooling, AC/DC power, battery, power
distribution, security, monitoring and fire
systems.

IP55 protection and thermal insulated for


outdoor deployment -35C ~ 45C ambient.

Customize with Expert


AgileHubTM Series

Technical Data – AgileHub Outdoor Micro Data Center – IEC Power Type
Product Model ATM-03-H01W ATM-06-H01K ATM-10-H02K ATM-10-H02R ATM-20-H03K Customized

Available Space for IT -U 33U 27U 67U 73U 101U <= 3 *42U

Available Power for IT -kW 1.3 3.5 5.0 7.0 12.0 Per Definition

Redundancy N N N N N N / N+1 / 2N

Width -mm 905 1400 2000 2600 2600 <= 2600

Depth -mm 1080 1600 1600 1600 1600 1600

Height -mm 2105 2300 2300 2300 2300 2300

Weight -kg 165 560 890 1160 1242 Per Definition

IP Level IP55 IP55 IP55 IP55 IP55 IP55

Input Power 220-240V/1P/50Hz 220-240V/1P/50Hz 220-240V/1P/50Hz 220-240V/1P/50Hz 380-415V/3P/50Hz Per Definition

Recommended Breaker 32A 1P 63A 1P 63A 1P 63A 1P 63A 3P Per Definition

Power Section

UPS -kVA Optional 6.0 10.0 10.0 20.0 3 - 200kVA

UPS Mount Type Optional Rack Rack Rack Rack Rack

Standard UPS Battery Optional 2* VRLA 12V/9AH 16Pcs 2* VRLA 12V/9AH 16Pcs 2* VRLA 12V/9AH 16Pcs 2* VRLA 12V/9AH 40Pcs <= 4 hour

AC PDU 1* Basic 8 Slots 1* Basic 16 Slots 2* Basic 16 Slots 2* Basic 16 Slots 3* Basic 16 Slots Per Definition

-48VDC -A 2* 30A Optional Optional Optional Optional 10 – 600A

Standard 48VDC Battery Lithium 1* 48V50AH Optional Optional Optional Optional <= 4 hour

48VDC Power Distribution BLVD 8* 1P Optional Optional Optional Optional Per Definition

Cooling Section

Cooling Type Packaged DX Split DX Split DX Split DX Split DX Packaged / Split

Mount Type Wall Rack Rack Row Rack Wall / Rack / Row

Capacity-kW 1.5 3.9 5.9 7.6 12.8 1.5 - 90.0kW

DCIM Section

Local Display Touch Screen Touch Screen Touch Screen Touch Screen Touch Screen Touch Screen

Remote Access Web Access Web Access Web Access Web Access Web Access Web Access

Reporting Protocol Modbus-TCP Modbus-TCP Modbus-TCP Modbus-TCP Modbus-TCP Modbus-TCP

UPS Mgmt. Yes Yes Yes Yes Yes Yes

Cooling Mgmt. Yes Yes Yes Yes Yes Yes

Temperature Humidity Sensor Yes Yes Yes Yes Yes Yes

Fire Sensor Smoke Smoke Smoke Smoke Smoke Smoke

Water Sensor Yes Yes Yes Yes Yes Yes

Door Sensor Front/Rear Front/Rear Front/Rear Front/Rear Front/Rear Front/Rear

Security Section

Access Control RFID/Key RFID/Key RFID/Key RFID/Key RFID/Key RFID/Key

Video Surveillance Optional Optional Optional Optional Optional Optional

Fire Fighting Section


FM200 Rack Module FM200 Rack Module FM200 Rack Module FM200 Rack Module FM200 Rack Module FM200 Rack Module
Fire Extinguisher
(Opt.) (Opt.) (Opt.) (Opt.) (Opt.) (Opt.)

Early Detection Vesda (Opt.) Vesda (Opt.) Vesda (Opt.) Vesda (Opt.) Vesda (Opt.) Vesda (Opt.)

Customize with Expert


AgileHubTM Series

Technical Data – AgileHub Outdoor Micro Data Center – USA Power Type
Product Model ATM-03-H01W ATM-06-H01K ATM-10-H02K ATM-10-H02R ATM-20-H03K Customized

Available Space for IT -U 33U 26U 66U 69U 94U <= 3 *42U

Available Power for IT -kW 1.3 3.5 5.0 7.0 12.0 Per Definition

Redundancy N N N N N N / N+1 / 2N

Width -mm 905 1400 2000 2600 2600 <= 2600

Depth -mm 1080 1600 1600 1600 1600 1600

Height -mm 2105 2300 2300 2300 2300 2300

Weight -kg 165 560 890 1160 1242 Per Definition

IP Level IP55 IP55 IP55 IP55 IP55 IP55

Input Power 208-240V/2P/60Hz 208-240V/2P/60Hz 208-240V/2P/60Hz 200-230V/3P/50-60Hz 200-230V/3P/50-60Hz Per Definition

Recommended Breaker 32A 1P 63A 1P 63A 1P 32A 3P 63A 3P Per Definition

Power Section

UPS -kVA Optional 6.0 10.0 10.0 2* 10.0 3 - 200kVA

UPS Mount Type Optional Rack Rack Rack Rack Rack

Standard UPS Battery Optional 2* VRLA 12V/9AH 16Pcs 2* VRLA 12V/9AH 16Pcs 2* VRLA 12V/9AH 16Pcs 4* VRLA 12V/9AH 16Pcs <= 4 hour

AC PDU 1* Basic 8 Slots 1* Basic 16 Slots 2* Basic 16 Slots 2* Basic 16 Slots 3* Basic 16 Slots Per Definition

-48VDC -A 2* 30A Optional Optional Optional Optional 10 - 600A

Standard 48VDC Battery Lithium 1* 48V50AH Optional Optional Optional Optional <= 4 hour

48VDC Power Distribution BLVD 8* 1P Optional Optional Optional Optional Per Definition

Cooling Section

Cooling Type Packaged DX Split DX Split DX Split DX Split DX Packaged / Split

Mount Type Wall Rack Rack Row Rack Wall / Rack / Row

Capacity-kW 1.5 3.9 5.9 7.6 12.8 1.5 - 90.0kW

DCIM Section

Local Display Touch Screen Touch Screen Touch Screen Touch Screen Touch Screen Touch Screen

Remote Access Web Access Web Access Web Access Web Access Web Access Web Access

Reporting Protocol Modbus-TCP Modbus-TCP Modbus-TCP Modbus-TCP Modbus-TCP Modbus-TCP

UPS Mgmt. Yes Yes Yes Yes Yes Yes

Cooling Mgmt. Yes Yes Yes Yes Yes Yes

Temperature Humidity Sensor Yes Yes Yes Yes Yes Yes

Fire Sensor Smoke Smoke Smoke Smoke Smoke Smoke

Water Sensor Yes Yes Yes Yes Yes Yes

Door Sensor Front/Rear Front/Rear Front/Rear Front/Rear Front/Rear Front/Rear

Security Section

Access Control RFID/Key RFID/Key RFID/Key RFID/Key RFID/Key RFID/Key

Video Surveillance Optional Optional Optional Optional Optional Optional

Fire Fighting Section


FM200 Rack Module FM200 Rack Module FM200 Rack Module FM200 Rack Module FM200 Rack Module FM200 Rack Module
Fire Extinguisher
(Opt.) (Opt.) (Opt.) (Opt.) (Opt.) (Opt.)

Early Detection Vesda (Opt.) Vesda (Opt.) Vesda (Opt.) Vesda (Opt.) Vesda (Opt.) Vesda (Opt.)

Customize with Expert


AgileModTM Series

Monitoring System Cabling System Closed Aisle System


Module-level monitoring system + Row-level cable ladder supports It consists of horizontally
local touch screen, supporting 3D, wiring between two columns of racks, expanding modular skylights,
temperature cloud map and asset and M-type cabling on the top of the supports and doors, which can
management, etc rack supports isolated wiring be opened automatically.

Access Door Power System Server Rack Cooling System


All-glass door design Integrated design of Standard 19-inch server Row-mount Cooling
electric sliding door modular UPS and power cabinet, 75% front and system with DX or CW,
assembly, support distribution cabinet, rear mesh door through- the same appearance
fingerprint + password + Independent configuration hole ratio, static load up to style as the server rack
RFID access control is optional 1800kg

Customize with Expert


AgileModTM Series

Technical Data – AgileMod Indoor Micro Data Center – IEC/US Power Type
Product Model Configure to Order

Available Space for IT -U <= 40 * 42U

Available Power for IT -kW <= 15kW/Rack

Redundancy N / N+1 / 2N

Width -mm Per Definition

Depth -mm 1100 / 1200 Rack

Height -mm 2000

Weight -kg Per Definition

Input Power 220-240V/1P/50-60Hz or 380-415V/3P/50-60Hz

Recommended Breaker Per Definition

Power Section

UPS -kVA 3kVA - 200kVA

UPS Type Rack / Modular

Standard Battery <= 4hours backup time

PDU Basic / Smart(Opt.)

Cooling Section

Cooling Type Packaged DX / Split DX / Chilled Water

Mount Type Row / Rack / Top

Capacity-kW 3.9-90kW

Emergency Ventilation √

DCIM Section

Local Display Touch Screen

Remote Access Web Access / Email / SMS(Opt.)

Reporting Protocol Modbus-TCP / SNMP(Opt.)

UPS Mgmt. Yes

Cooling Mgmt. Yes

Temperature Humidity Sensor Yes

Fire Sensor Smoke

Water Sensor Yes

Door Sensor Front / Rear

Security Section

Access Control RFID / Finger / PIN

Video Surveillance Optional

Fire Fighting Section

Fire Extinguisher FM200/Novec(Opt.)

Early Detection Vesda (Opt.)

Customize with Expert


Centralized Monitoring System

Centralized Monitoring system collects all the distributed Edge Micro Data
Centers into a single console, to easily control, alert, and manage the remote
sites, and simplify the multiple data center operation.

Monitoring Host Server

Europe
North America

Asia-Pacific

Africa

Latin America

Customize with Expert


Why Work with Us

We Expertise Micro Data Centers

Expertise Speed Flexibility


Products designed A professional team Fully customizable as
with heart featuring always standby with per your
reliable quality and service spirit and requirements to build
balanced quick response to your own product
performance to support your solution and boost
protect your business agility. your own business.
business revenue.

Certifications

Customize with Expert


Our Customer Success

We always think in customer perspective to support our customers


success. We build our long term success with the values of
customer first.

Customize with Expert


Our Global Deployments

Customize with Expert


We believe the world is
being totally connected.
The connections are
creating digital intelligence
and a better future.

We create prefabricated
micro data center
products to build
foundation of digital
future.