0% found this document useful (0 votes)
24 views

Emc & Rfi

The document discusses electromagnetic compatibility (EMC) and radio frequency interference (RFI) of drive systems. It provides details on immunity standards compliance and emission standards compliance which depends on installation guidelines and use of specified RFI filters. It also lists technical specifications for various RFI filter types including current ratings, power dissipation, ingress protection, temperature rise, dimensions, weights and other details.

Uploaded by

Kerolos Mekhael
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
24 views

Emc & Rfi

The document discusses electromagnetic compatibility (EMC) and radio frequency interference (RFI) of drive systems. It provides details on immunity standards compliance and emission standards compliance which depends on installation guidelines and use of specified RFI filters. It also lists technical specifications for various RFI filter types including current ratings, power dissipation, ingress protection, temperature rise, dimensions, weights and other details.

Uploaded by

Kerolos Mekhael
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

electro magnetic compatibility (EMC)

& radio frequency interference (RFI)

Electromagnetic compatibility (EMC)


conducted emission
This is a summary of the EMC performance of the
Drive. For full details, refer to the Unidrive EMC Data
Sheet which can be obtained from a Drive Centre or
distributor listed on the back cover.

Immunity
Compliance with immunity standards does not
depend on installation details. The Drive meets
EN50082–2 (generic immunity standard for the
industrial environment) and the following specifications
from the IEC1000–4 group (derived from IEC801):
Part 2, Electrostatic discharge: Level 3
Part 3, Radio frequency field: Level 3
Part 4, Transient burst: Level 4 at the control
terminals
Part 4 Transient burst:
Level 4 at the control terminals
Level 3 at the power terminals
Part 5, Surge (at the AC supply terminals):
Level 4 line-to-ground
Level 3 line-to-line (as specified by
EN50082–2 informative annex)
Part 6, Conducted radio frequency:
Level 3

Emission
Compliance with emission standards depends on
rigorous adherence to the installation guidelines,
including the use of the specified RFI filter in the AC
supply circuit. Compliance also depends on the PWM
switching frequency used in the output stage of the
Drive, and the length of the motor cable. For full
details, refer to the Unidrive EMC Data Sheet which
can be obtained from a Drive Centre or distributor
listed at the end of this Product Data Guide.

24
electro magnetic compatibility (EMC)
& radio frequency interference (RFI)

RFI Filter Ratings


Type Part number Max. Power Ingress Max. ambient Case
continuous dissipation at protection temperature at temperature rise
current rated current rated current at rated current
A 4200-0010 10A 25W IP20 50°C (122°F) <30°C (86°F)
B 4200-0027 27A 40W IP20 50°C (122°F) <40°C (104°F)
C 4200-1051 50A 60W IP00 50°C (122°F) <40°C (104°F)
D 4200-1071 75A 100W IP00 50°C (122°F) <40°C (104°F)
E 4200-1111 110A 120W IP00 50°C (122°F) <40°C (104°F)
F 4200-1171 170A 150W IP00 40°C (104°F) <55°C (131°F)
G 4200-1302 300A 300W IP00 50°C (122°F) <40°C (104°F)

Main Ratings Overall Dimensions


* Above 40°C (104°F), the current rating is
Filter type Dimension
reduced by 1.6A/°C (0.88A/°F) H W D

AC Supply Ratings A 396mm 50mm 113mm


Voltage (phase-to-phase and phase-to-ground): 15 9/16 in 1 15/16 in 4 7/16 in
480V +10%
B 396mm 75mm 113mm
AC supply frequency: 48 to 62 Hz 15 9/16 in 2 15/16 in 4 7/16 in

C 330mm 190 mm 145mm


Ground Leakage Current 13 in 7 1/2 in 5 11/16 in
The ground-leakage current, phase-to-phase and
phase-to-ground, when the AC supply is 400V at D 330mm 190mm 145mm
50Hz is as follows: 13 in 7 1/2 in 5 11/16 in

CONDITION A B C to G E 440mm 200mm 145mm


Balanced 5.6mA 7.4mA 55mA 17 5/16 in 7 7/8 in 5 11/16 in
One phase disconnected 41mA 57.9mA 350mA
F 490mm 200mm 145mm
For other AC supply voltages and currents, scale 19 1/4 in 7 7/8 in 5 11/16 in
the value of leakage current proportionally.
G 380mm 495mm 250mm
14 5/16 in 19 1/2 in 9 13/16 in
Discharge Resistors
A and B: 330 KΩ internally between phases, with
the star point connected by a 1M resistor to ground. Weights
C to G: 10 MΩ internally between each phase FILTER TYPE kg lb
and ground. A 2 5
B 2.7 6
Maximum Current Overload C 7.4 16
150% of rated current for 60 seconds. D 8 18
E 12.3 27
F 16 35
G 35 77

25