0% found this document useful (0 votes)
266 views

Manual Honeywell 2010

Uploaded by

JAZMIN GALVEZ
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
266 views

Manual Honeywell 2010

Uploaded by

JAZMIN GALVEZ
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1028

spine

TRADELINE Catalog

2010-2011 Product Catalog


Automation and Control Solutions

Combustion Controls
Environmental and Combustion Controls
Environmental and
Honeywell International Inc.
1985 Douglas Drive North
Golden Valley, MN 55422 2010-2011 Product Catalog
Honeywell Limited-Honeywell Limitée
35 Dynamic Drive
Toronto, Ontario M1V 4Z9 ® U.S. Registered Trademark
© 2010 Honeywell International Inc.
customer.honeywell.com 70-6910 Rev. 04-10

spine
In addition to the most up-to-date information on all of the Honeywell products you have seen
AUTOMATION AND CONTROL SOLUTIONS PRODUCTS
before, the 2010 - 2011 Tradeline® catalog includes: WARRANTY POLICY
• RedLINK™ wireless thermostats and zoning products Honeywell warrants the products in this catalog (except those parts designated on Honeywell's price lists as not covered by this warranty) to be free from
defects due to workmanship or materials, under normal use and service, for the following warranty periods. Honeywell VisionPRO®, Commercial
• Pressure-regulated Control Valves VisionPRO™, FocusPRO®, PRO 4000, PRO 3000, LineVolt™ PRO, Digital Round™, and Modern Round ™ (T87K, N) Series Thermostats with a date
• Commercial wireless occupancy sensors code of 0501 or later: sixty (60) months from date of installation. CommercialPRO, PRO 2000 and PRO 1000 thermostats: twenty-four (24) months from
date of installation. AUBE branded thermostats, timers, and switches: thirty-six (36) months from date of installation. All other Honeywell thermostats and
• SOLA Controllers and Displays thermostats with a date code of 0452 or earlier: twelve (12) months from date of installation, unless specified otherwise. Honeywell Air Cleaners,
Humidifiers, Ventilators, Ultraviolet Treatment and Zoning Products with a date code of 0501 or later, excluding replacement maintenance parts: sixty (60)
• Delphi Combustion Systems months from date of installation. Indoor air quality parts F50, F52, F300, F200, F150, UV100E, HE225, HE265, HE365, with date codes of 0452 or earlier,
excluding replacement maintenance parts: sixty (60) months from date of installation. All other Honeywell indoor air quality and zoning products with a date
• SmartVFD COMPACT Drives code of 0452 or earlier: twenty-four (24) months from date of installation, unless specified otherwise. Variable frequency drive devices (VFD) and
• SmartHVAC Drives and SmartHVAC BYPASS Drives and bypass assemblies accessories: new products for thirty-six (36) months and factory refurbished drives for twelve (12) months from date of installation when start-up and
commissioning is performed by Honeywell VFD Authorized and trained personnel. All VFD warranty return products must have prior authorization (Form
• TrueDRY Dehumidification No. 87-0284) and be returned only to the VFD Service Center in Chattanooga, TN. MS, MN and Fact Acting 2-position Direct Coupled Actuators: sixty (60)
months from date of installation. The warranty period for all other products is twelve (12) months from date of installation.
• TrueIAQ Controls If a product is defective due to workmanship or materials, is removed within the applicable warranty period, and is returned to Honeywell in accordance
• Bath Fan Controls with the procedure described below, Honeywell will, at its option, either repair, replace or credit the customer for the purchase price of the product, in
accordance with the procedure described below. This warranty extends only to persons or organizations who purchase products in this catalog for resale.
• The GlowFly™ Universal HSI Kit The expressed warranty above constitutes the entire warranty of Honeywell with respect to the products in this catalog and IS IN LIEU OF ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR
PURPOSE. IN NO EVENT SHALL HONEYWELL BE RESPONSIBLE FOR ANY CONSEQUENTIAL DAMAGES OF ANY NATURE WHATSOEVER.

INSTRUCTIONS—INSTALLING OR listed on Honeywell’s Returned Goods of such return, as shown on


Order (form 71-96024) or a similar form; Honeywell’s then current price sheet.)
SERVICING CONTRACTOR OR (iii) packed separately from other returns Honeywell reserves the right to
For more information on the products in this catalog, a cross-reference to obsolete products, DEALER and protected from shipping damage; disallow this credit option in cases of
When replacing a Honeywell product under (iv) have certification by the installer or warranty abuse.
product pricing, production tools and the latest information about new products please visit our warranty, including those products furnished on servicing dealer that the product was 2. REPAIR OR REPLACEMENT
original heating and/or cooling equipment, you removed, due to failure, within the PROCEDURE. Honeywell will, at its
website at http://customer.honeywell.com should rely on your local Honeywell Wholesaler applicable warranty period; option, either repair or replace the
or Distributor for prompt and efficient product (v) are received transportation pre-paid at: product free of charge and return it or its
replacement service. Honeywell Return Goods replacement lowest cost transportation
A Honeywell Returned Goods Identification Tag Dock 4 MN10-3860 prepaid. The replacement will be a
(form 87-0030) or an electronic data notification 1885 Douglas Drive functionally equivalent new TRADELINE
system must be completed and approved by the Golden Valley, MN 55422 product. Premium transportation will be
servicing dealer/contractor prior to submitting the (vi) and are found by Honeywell’s inspection used at customer’s request and expense.
product to the Honeywell Wholesaler or to be defective in workmanship or The warranty will not be honored if:
Distributor. (Tags may be obtained from the materials under normal use and service
will be handled in accordance with one of the two (i) product is damaged or missing parts or
Wholesaler or Distributor in advance.) No accessory items including batteries.
warranty claim for product replacement or credit following procedures, as specified by the
customer making the return: (ii) product exhibits evidence of field
will be honored by the Wholesaler/Distributor misapplications.
without a completed warranty tag attached or All VFD warranty return products must have prior Final disposition of any warranty claim will be
electronic notification. authorization (Form No. 87-0284) and be determined solely by Honeywell. If inspection by
returned only to the VFD Service Center in
INSTRUCTIONS—WHOLESALER OR Chattanooga, TN.
Honeywell does not disclose any defect covered
by the warranty, the product will be returned or
DISTRIBUTOR 1. CREDIT PROCEDURE. Honeywell will scrapped as instructed by the customer and
The following will apply to the return of any issue credit, at Honeywell’s lowest Honeywell’s regular service charges will apply.
product to Honeywell under this warranty: wholesaler net price in effect at the Products returned to the customer may be sent
Any products which are not variable frequency time of the return (as set forth on shipping charges collect.
drives and are: Honeywell’s then current price sheet) If you have any questions relative to product
(i) identified with Honeywell’s Returned or at the actual invoice amount if a returns to Honeywell, contact your Customer
Goods Identification Tag (form copy of that invoice is attached to the Care Representative:
87-0030), or electronic notification packing list. (TRADELINE
Replacement Exchange Products will Honeywell International Inc.
system;
be at Honeywell’s lowest replacement Customer Care MN10-131A
(ii) are listed individually with Returned
exchange net price in effect at the time 1985 Douglas Drive
Goods ID Tag numbers and date codes
Golden Valley, MN 55422
(763) 954-5720

SPECIAL MESSAGE TO INDUSTRIAL is furnished with Honeywell controls or Your supplier can rely on its local Honeywell
components (refer to your owner’s Wholesaler/Distributor or Honeywell for prompt
USERS AND BUILDING OWNERS manual furnished with the equipment). replacement.
Thank you for using Honeywell products.
3. A control has failed on your existing If you have any questions, need additional
As a user, when you purchase a Honeywell commercial and/or process heating and/ information or would like to comment on
product from this catalog you should expect or cooling equipment and is replaced by a Honeywell’s products or services, please write or
performance from the product and, if it fails, Honeywell TRADELINE product. phone:
replacement of the product by the installing Honeywell International Inc.
dealer. With few exceptions, you utilize the services of a
Customer Care MN10-131A
competent plumbing, heating and/or cooling
Typically, you will have purchased a Honeywell 1985 Douglas Drive North
dealer/contractor for new or replacement work
product under the following circumstances: Golden Valley, MN 55422-4386
performed.
1. To modernize or refurbish your existing (763) 954-5720
commercial and/or process control Although our warranty does not extend to you, or check your telephone directory (white pages)
system. Honeywell does extend a warranty to your for one of many Honeywell field sales offices.
2. You have purchased new commercial supplier.
and/or process heating, cooling, air
cleaning or humidification equipment that

Rev. 04-10 70-0568


Table of Contents
Model Number Index ................................................................... iii General Information ................................................................. xvi
Subject Index.............................................................................. vii Reference Information ............................................................. xvii
ISO 9001 ................................................................................... xv Authorized Distributors............................................................ xxiv

Home Control Thermostats and Zoning


Electric Heat Thermostats .......................................................... 1 Telephone Access Module........................................................ 37
Programmable Thermostats....................................................... 6 Thermostats Parts and Accessories ......................................... 38
Temperature Sensors............................................................... 15 Thermostat Guards ................................................................... 39
Non-Programmable Thermostats ............................................. 16 TrueZONE™ Zoning Panels and Kits ....................................... 41
Freeze Warning........................................................................ 25 EnviraZONE Panels and Kits.................................................... 44
RedLINK™ Products ................................................................ 26 EnviraZONE Accessories ......................................................... 45
RedLINK™ Wireless Products ................................................. 27 Zone Control Panel Accessories............................................... 46
RedLINK™ Accessories........................................................... 33 Zone Control Dampers.............................................................. 47
Communicating Thermostats ................................................... 35 Zone Damper Accessories........................................................ 53

Indoor Air Quality


Media Air Cleaners................................................................... 55 Bypass Humidifiers ................................................................... 81
Electronic Air Cleaners............................................................. 59 Fan Humidifiers......................................................................... 84
Electronic Air Cleaner Filters.................................................... 63 Humidifier Replacement Pads and Filters................................. 86
Return Grille Electronic Air Cleaners........................................ 64 Humidity Controllers.................................................................. 88
HEPA Air Cleaners................................................................... 67 Ultraviolet Air Treatment Systems ............................................ 90
Replacement Media Filters....................................................... 69 Fresh Air Ventilation Systems................................................... 93
Air Cleaner Parts and Accessories........................................... 74 Bath Fan Control/Fresh Air Ventilation ..................................... 97
TrueDRY Dehumidification System.......................................... 77 Fresh Air Ventilation.................................................................. 97
TrueSTEAM Humidification System ......................................... 79 Sail Switches............................................................................. 99
TrueIAQ Control ....................................................................... 80 Carbon Monoxide Alarm ......................................................... 100

Residential Combustion Controls


Combination Gas Controls ..................................................... 101 Contractors Selection Guide ................................................... 153
Millivoltage Combination Gas Controls .................................. 114 Relays ..................................................................................... 156
Gas Valve Selection Guide .................................................... 115 Relays Parts and Accessories ................................................ 162
SmartValve® System Controls............................................... 117 Electric Heat Sequencer Selection Guide............................... 164
SmartValve® Selection Guide................................................ 124 Fan Centers ............................................................................ 166
Gas Valves Parts and Accessories ........................................ 126 Fan Center Selection Guide.................................................... 167
Thermocouples and Thermopiles........................................... 128 Transformers........................................................................... 168
Thermopiles and Thermocouples Selection Guide ................ 130 Transformer Selection Guide .................................................. 174
Pilot Burners........................................................................... 131 Oil Primaries Cross Reference ............................................... 175
Pilot Burner Parts and Accessories........................................ 134 Oil Primaries ........................................................................... 176
Ignition Pilot Modules ............................................................. 136 Oil Systems Diagnostics ......................................................... 179
Ignition Pilot Modules Selection Guide................................... 140 Flame Detectors...................................................................... 180
Gas Ignition Module Accessories ........................................... 141 Magnetic Valves...................................................................... 181
Igniter Bracket Replacement Cross Reference ...................... 142 Pressuretrol Controller ............................................................ 182
Igniters and Sensors .............................................................. 143 Fan and Limit Controllers........................................................ 183
Pressure Switches.................................................................. 144 Aquastat Controllers ............................................................... 186
Electronic Fan Timers ............................................................ 145 Well Assemblies...................................................................... 202
Contactors .............................................................................. 146

Hydronic Controls
AQUATROL Zoning System................................................... 203 Backflow Preventers ............................................................... 253
Hydronic Switching Relays..................................................... 214 Boiler Fill Valves ..................................................................... 254
Transformer for Hydronic Heating Controls............................ 221 Thermometers and Gauges .................................................... 255
Residential Heating Valves and Actuators ............................. 222 Residential Expansion Tanks.................................................. 256
Motorized Zone Valves........................................................... 225 Residential Expansion Tank Kits ............................................ 258
Manifold Zone Valves............................................................. 240 Thermostatic Radiator Valves and Actuators.......................... 260
Differential Pressure Regulators ............................................ 243 Commercial Air Eliminators..................................................... 273
Air Vents and Eliminators ....................................................... 244 Commercial Expansion Tanks ................................................ 274
FlowCheck Valves.................................................................. 252

Water Controls
Thermostatic Mixing Valves ................................................... 281 Water Filter Parts and Accessories......................................... 295
Pressure Regulating Valves ................................................... 288 Float Valves ............................................................................ 296
Pressure Regulating Valves Parts and Accessories .............. 291 Commercial Mixing Valves...................................................... 297
Water Filters ........................................................................... 292

Building Automation
Excel 5000 System................................................................. 299 Spyder Controllers .................................................................. 342
WEBs-AX System .................................................................. 312 Building Automation Appliances ............................................. 344
WEBs-AX Security System .................................................... 326 Light Commercial Building Systems ....................................... 346
WEBs R2 System................................................................... 338 Legacy Building Systems........................................................ 356

70-6910 i
Table of Contents
Commercial Components
Pressure Controllers ............................................................... 361 InfraRed Thermostat Interface (IR-TIM) ................................. 537
Refrigeration Controllers ......................................................... 362 Communicating Thermostats.................................................. 538
Sail Switches........................................................................... 364 WebStat Controller ................................................................. 539
Temperature Controllers ......................................................... 365 Commercial Thermostat Resources ....................................... 540
Commercial Rectangular Dampers......................................... 384 Timers..................................................................................... 541
Commercial Round Dampers.................................................. 387 Pressure-regulated Control Valves......................................... 542
Direct Coupled Damper Actuators .......................................... 389 Control Ball Valves ................................................................. 566
Economizer Systems .............................................................. 435 Butterfly Control Valves .......................................................... 601
Economizer Controllers and Logic Modules ........................... 436 Flanged Globe Valves ............................................................ 640
Economizer Damper Actuators ............................................... 441 Threaded Globe Valves.......................................................... 648
Economizer Sensors............................................................... 443 Globe Valve Accessories and Replacement Parts ................. 653
Modutrol IV™ Motors .............................................................. 445 Double-Seated Globe Valves ................................................. 661
Kit Mounted Motors................................................................. 470 Cage Valves ........................................................................... 662
Damper and Valve Linkages................................................... 472 Cartridge Globe Valves .......................................................... 663
Carbon Dioxide (CO2) Sensors .............................................. 478 Cartridge Cage Valves ........................................................... 668
Current Switches..................................................................... 480 Fan Coil Valves ...................................................................... 678
Dew Point Sensors ................................................................. 483 Cartridge Globe Valve Actuators ............................................ 680
Humidity Sensors.................................................................... 484 VC Valve Actuators ................................................................ 682
Pressure Sensors ................................................................... 488 Fan Coil Actuators .................................................................. 685
Temperature Sensors ............................................................. 490 Direct Coupled Valve Actuators.............................................. 687
Submeters............................................................................... 509 Valve Actuator Accessories.................................................... 692
Fan Coil Thermostats.............................................................. 516 SmartVFD COMPACT............................................................ 693
Wireless Occupancy Solutions ............................................... 520 SmartVFD HVAC.................................................................... 695
Line Voltage Thermostats ....................................................... 522 Variable Frequency Drives ..................................................... 701
Proportional Thermostats........................................................ 526 Variable Frequency Drives with Bypass ................................. 708
Programmable Commercial Thermostats ............................... 528

Pneumatic Controls
Pneumatic Humidistats ........................................................... 747 Pneumatic Relays................................................................... 782
Pneumatic Thermostats .......................................................... 750 Pneumatic Switches ............................................................... 792
Pneumatic Transducers .......................................................... 765 Pneumatic Damper Actuators................................................. 799
Pneumatic Velocity Sensors/Controllers................................. 766 Pneumatic Valve Actuators .................................................... 812
Pneumatic Temperature Controllers ....................................... 768 Pneumatic Valves................................................................... 817
Pneumatic Pressure Controllers ............................................. 772 Pneumatic Gauges ................................................................. 834
Pneumatic Humidity Sensors.................................................. 778 Pneumatic Accessories .......................................................... 835
Pneumatic Temperature Sensors ........................................... 779 Pneumatic Definitions and Abbreviations ............................... 842

Commercial/Industrial Combustion Controls


Product Selection Matrix ......................................................... 845 Butterfly Valve Linkages ......................................................... 930
Microprocessor Burner Controls ............................................. 864 Diaphragm Gas Valves........................................................... 931
SOLA Controllers .................................................................... 894 Butterfly Gas Valves ............................................................... 937
SOLA Displays........................................................................ 896 Gas Valve Actuators............................................................... 939
ControLinks™ Fuel Air Control System .................................. 899 Industrial Gas Valves.............................................................. 946
Delphi Combustion System..................................................... 903 Pilot Gas Valves ..................................................................... 952
Advanced Burner Controls...................................................... 905 Solenoid Gas Valves .............................................................. 953
Network Communications Interface ........................................ 907 Pressure Switches.................................................................. 956
Flame Amplifiers ..................................................................... 908 Pressure and Limit Controllers ............................................... 960
Flame Rods and Flame Rod Holders...................................... 911 Modernization and Replacement............................................ 969
Flame Detectors...................................................................... 913 Electromechanical Burner Controls ........................................ 972
Pilot Burners ........................................................................... 924 Reset Temperature Controls .................................................. 976
Commercial Hydronic Controllers ........................................... 927 Testers and Demonstrators .................................................... 979
Ignition Transformers .............................................................. 928 Flame Safeguard Legacy Parts .............................................. 983
Firing Rate Motors and Linkages ............................................ 930

Training Materials
DVD/Videotapes ..................................................................... 985 FSG Textbook ........................................................................ 992
Training Booklets .................................................................... 986 Reference Manuals ................................................................ 993
Programmed Instruction Books............................................... 988 Lab Trainers ........................................................................... 995
Service Publications................................................................ 989 Ordering Information............................................................... 997
Classroom Training................................................................. 990

ii customer.honeywell.com 70-6910
Model Number Index
Numerics C7232 .................... 63-2571 ...................... 435, 478 EC7850 .................. 66-2041 ............................... 866
121371A.................68-0040 ............................... 202 C7400 .................... 63-1143 ...............................443 EC7885 .................. 66-2035 ............................... 876
123514A.................65-0093 ............................... 980 C7400A.................. 63-1143 ...............................435 EC7890 .................. 66-2032 ............................... 879
198162 ...................63-2230 ............................... 466 C7400C ................. 63-1143 ...............................435 EC7895 .................. 65-0205 ............................... 880
2001 ....................62-86-25-10 ............................ 903 C7600A,C .............. 63-2418 ...............................484 ER150 .................... 68-0171 ................................. 93
203659 ...................65-0093 ............................... 980 C7600B.................. 63-2166 ...............................484 ER200 .................... 68-0171 ................................. 93
220736 ...................63-2228 ............................... 465 C7632 .................... 63-2615 ...................... 435, 479 Excel 100 ............. 95-2035-2 ............................. 304
50014064-001 ............. ...................................... 537 C7650 .................... 63-2499 ...............................444 Excel 50 ................. 74-3668 ............................... 304
50017460 ...............62-0233 ............................... 466 C7660 .................. 63-2670EF .................... 435, 444 Excel 800 System .. 63-1326 ............................... 303
50021579 .................... ...................................... 502 C7735 .................... 69-1521 .................................34 Excel 800 ............... 63-1326 ............................... 302
50022037 .................... ........................................ 45 C7750 .................... 95-7508 ...............................497
50035430 ...............62-0296 ............................... 489 C7770A.................. 95-7557 ...............................497 F
51452354 ............62-86-33-48 ............................ 904 C7772 .................... 68-0213 ...............................498 F100.....................68-0239EF .............................. 55
99-4218-14-07 ............ ...................................... 906 C7835 .................... 69-1463 .................................45 F170 ............................ ..................................... 296
C7915 .................... 65-0292 ...............................920 F200.....................68-0238EF .............................. 57
A C7927 .................... 60-2026 ...............................920 F300.....................68-0240EF .............................. 59
C7961 .................... 65-0267 ...............................921 F500....................... 68-0263 ................................. 67
A7184 ......................... ...................................... 180
C7962 .................... 65-0277 ...............................922 F52......................... 68-0074 ................................. 64
A7800.....................65-0110 ............................... 979
C8600 .................. 69-1513EF .............................100 F74C ...................... 62-3061 ............................... 292
A7999.....................66-1136 ............................... 902
CARE..................... 74-5136 ...............................300 F76......................... 62-3015 ............................... 293
ABC900A,B ............63-9751 ............................... 905
Class 100............... 63-1335 ...............................509 FC100 .......................... ....................................... 70
AM-1 Series ........ SD_IS_150 ............................ 281
Class 200............... 63-1337 ...............................510 FC100 .................... 68-3062 ................................. 55
AMX Series ............62-3074 ............................... 284
Class 500............... 63-1338 ...............................511 FC20 ...................... 68-3062 ................................. 71
AMX300 Series ......62-3112 ............................... 286
CLEPAS ................ 77-2070 ...............................792 FC200 .................... 68-3062 ................................. 57
AP400,AP401,AP402 . ...................................... 248
CP980.................... 77-9869 ...............................766 FC200SB ..................... ..................................... 252
AP5027-30 .............69-1581 ............................... 144
CP980C, D,E,F...... 75-7270 ...............................767 FC201SB ..................... ..................................... 252
AP5208-30 .............69-1581 ............................... 144
CR7890 ................. 65-0259 ...............................864 FC2200 ........................ ....................................... 70
AP5210-30 .............69-1581 ............................... 144
CSP ................ 63-2650, 63-2651 ........................480 FC2400 ........................ ....................................... 70
AQ1000TN2 .........69-2005EF ............................. 212
CSS ................ 63-2650, 63-2651 ........................480 FC40 ...................... 68-3062 ................................. 71
AQ1000TP2 .........69-2245EF ............................. 213
CTP ................ 63-2654, 63-2656 ........................482 FF06....................... 62-3060 ............................... 294
AQ2000 Series.......69-1983 ............................... 210
CTS ................ 63-2654, 63-2656 ........................482 FM450.................... 62-3087 ............................... 254
AQ250 ....................69-1982 ............................... 203
AQ251 ....................69-1979 ............................... 205 FM911 ......................... ..................................... 254
AQ252 ....................69-1986 ............................... 207
D FSP1535 ................ 95-6910 ............................... 981
AQ254 ....................69-1987 ............................... 208 D05T...................... 62-3021 ...............................288 FSP5004 ................ 60-0219 ............................... 981
AQ255 ....................69-1981 ............................... 209 D1 Series............... 63-2671 ...............................384 FSP5075A1............ 95-8271 ............................... 975
AQ257 ....................69-1981 ............................... 209 D146 ...................... 62-3019 ...............................243 FSP5075A3............ 95-8271 ............................... 975
AQ25A....................69-2120 ............................... 204 D2 Series............... 63-2598 ...............................385 FV147 .......................... ..................................... 248
ARD........................68-0260 ................................. 47 D3 Series............... 63-2598 ...............................385 FV180 .................... 62-3086 ............................... 247
AT120.....................68-0054 ............................... 168 D690 ...................... 63-2577 ...............................387 FV180A .................. 62-3086 ............................... 247
AT140.....................68-0054 .......................168, 221 DG115 ................... 69-2072 .................................80 FV183 .................... 62-3086 ............................... 247
AT140.....................68-0247 ................................. 53 DH150 ................... 68-0301 .................................77
AT150.....................68-0054 ............................... 168 DM7600 ................. 63-2237 ...............................388 G
AT150.....................69-1014 ............................... 169 DP1025.................. 69-0874 ...............................147 GS200,GS250 ............. ..................................... 255
AT175A ..................68-0054 ............................... 168 DP103.................... 69-0874 ...............................147 GT161,GT162 .............. ..................................... 255
AT175F ..................69-1014 ............................... 170 DP1030.................. 69-0874 ...............................151
AT20.......................60-2254 ............................... 170 DP1040.................. 69-0874 ...............................147 H
AT40.......................60-2254 ............................... 170 DP2020.................. 69-0874 ...............................148
H46 ......................69-1000EF .............................. 88
AT72.......................60-2254 ............................... 171 DP2030.................. 69-0874 ...................... 148, 151
H600 ...................... 60-2089 ................................. 88
AT87.......................60-2254 ............................... 172 DP2040.................. 69-0874 ...................... 148, 151
H7012 .................... 74-1868 ............................... 485
AT88.......................60-2254 ............................... 173 DP3030.................. 69-0875 ...............................149
H7015B .................. 63-2583 ............................... 485
DP3040.................. 69-0875 ...............................149
H7018A1003 .......... 63-2660 ............................... 483
B DP3050.................. 69-0875 ...............................149
H705 ...................... 63-2144 .......................435, 436
DP3060...................DP3060 ...............................149
BP700,BP701.........62-3089 ............................... 253 H7625 .................... 63-1305 ............................... 486
DP3075...................DP3075 ...............................149
BP900,BP901.........62-3088 ............................... 253 H7635A .................. 63-1305 ............................... 486
DP3090.................. 69-0875 ...............................150
H7655 .................... 63-2166 ............................... 486
DP3AUX ................ 69-0875 ...............................152
C DP4040.................. 69-0875 ...............................150
H8908 ..................69-1341EF .............................. 89
C437 2000 Series ..68-0286 ............................... 956 HE225 .................... 68-0244 ................................. 81
DR65 .................. 69-2089EFS ..............................77
C437.......................60-2320 ............................... 957 HE265 .................... 68-0244 ................................. 81
DR90 ..................... 69-2407 .................................77
C554.......................60-2148 ............................... 180 HE365 .................... 68-0243 ................................. 84
DR-SEC-BAC .............. ......................................332
C6097.....................65-0285 ............................... 958 HM506 ................69-2286EFS ............................. 79
DR-SEC-LON .............. ......................................332
C7005.....................60-2033 ............................... 926 HM509 ................69-2286EFS ............................. 79
DS05...................... 62-3041 ...............................289
C7007.....................60-2024 ............................... 911 HM512 ................69-2286EFS ............................. 79
DS06...................... 62-3052 ...............................290
C7008.....................60-2024 ............................... 911 HP970 .................... 77-9832 ............................... 747
DSP3452 ..................... ......................................980
C7009.....................60-2024 ............................... 911 HP971 .................... 77-9833 ............................... 778
DSP3548 ..................... ......................................980
C7012.....................60-2398 ............................... 913 HP972 .................... 77-9834 ............................... 748
DSP3564 ..................... ......................................980
C7024.....................65-0156 ............................... 915 HR150.................... 68-0171 ................................. 95
DSP3822 ..................... ......................................980
C7027.....................60-2026 ............................... 916 HR200.................... 68-0171 ................................. 95
DSP3943 ..................... ......................................981
C7031.....................63-2590 ............................... 490 HV190 .......................... ..................................... 247
DSP3944 ..................... ......................................981
C7035.....................60-2026 ............................... 917 HVC0001 ............69-2316EFS ............................. 97
DSP3949 ..................... ......................................903
C7041.....................63-2590 ............................... 492 HVC0002 ............69-2316EFS ............................. 97
DSP3956 ..................... ......................................980
C7044.....................60-2026 ............................... 916 HVFDCD ................ 62-0312 ............................... 693
C7046.....................60-2350 .......................435, 495 HVFDSB ................ 63-4520 ............................... 696
E HVFDSD ................ 63-4520 ............................... 695
C7061.....................65-0223 ............................... 918
EA122A ................. 62-3038 ...................... 245, 246 HZ221 .................... 69-2200 ................................. 43
C7076.....................95-8269 ............................... 919
EA79...................... 62-3034 ...............................244 HZ221K.................. 69-2200 ................................. 43
C7089................. 69-2055EFS .......................15, 33
EARD..................... 68-0266 .................................47 HZ311 .................69-2069EFS ............................. 43
C7100.....................60-2521 ............................... 495
EC7810.................. 66-2040 ...............................865 HZ311K...............69-2069EFS ............................. 43
C7130.....................63-2044 ............................... 496
EC7820.................. 66-2040 ...............................865 HZ322 .................... 69-2199 ................................. 42
C7150.....................63-2072 .......................435, 443
EC7823.................. 66-2031 ...............................869 HZ322K.................. 69-2199 ................................. 42
C7170.....................63-2045 ............................... 496
EC7830.................. 66-2041 ...............................866 HZ432 .................... 69-2198 ................................. 41
C7189U .............. 69-1710EFS ............................. 15

70-6910 iii
Model Number Index
HZ432K ..................69-2198 ................................. 41 ML6161.................. 63-2209 ...............................405 PA404A,B .............. 60-2341 ............................... 182
ML6174.................. 63-2209 ...............................408 PM7910.................. 65-0300 ............................... 898
I ML6420.................. 63-2533 ...............................687 POPUP ........................ ....................................... 69
IO-16-H ..................95-7756 ............................... 318 ML6421.................. 63-2515 ...............................688 PP901 .................... 75-2558 ............................... 772
IO-34-H ..................95-7753 ............................... 318 ML6425.................. 63-2516 ...............................689 PP902 .................... 75-2558 ............................... 772
ML6984................ 95C-10939 .............................690 PP903 .................... 75-1326 ............................... 773
L ML7161.................. 63-2209 ...............................405 PP904 .................... 77-9275 ............................... 774
ML7174.................. 63-2209 ...............................408 PP905 .................... 75-5537 ............................... 775
L4006 .....................60-2104 ............................... 186
ML7420.................. 63-2533 ...............................687 PP97 ...................... 75-1075 ............................... 776
L4008 .....................60-2104 ............................... 188
ML7421.................. 63-2515 ...............................688 PUB........................ 63-1328 ............................... 342
L4029 .....................60-2263 ............................... 183
ML7425.................. 63-2516 ...............................689 PUL ........................ 63-2685 ............................... 342
L404F .....................60-2150 ............................... 960
ML7984................ 95C-10939 .............................691 PV075 .................... 62-3069 ............................... 249
L404T,V..................71-2429 ............................... 962
ML7999A ............... 65-0239 ...............................901 PV100 .................... 62-3069 ............................... 249
L4064 .....................68-0024 ............................... 184
ML7999B ............... 65-0264 ...............................901 PV125 .................... 62-3069 ............................... 249
L4064K ........................ ...................................... 185
ML8115.................. 63-2540 ...............................419 PV150 .................... 62-3069 ............................... 249
L4079 .....................60-2156 ............................... 963
ML8125.................. 63-2567 ...............................403 PV200 .................... 62-3069 ............................... 249
L4081 .....................60-2105 ............................... 191
ML8135.................. 63-2567 ...............................401 PV200F .................. 62-3093 ............................... 273
L408J .....................65-0287 ............................... 964
MN6105 ................. 63-2632 ...............................411 PV250 .................... 62-3069 ............................... 273
L4103 .....................60-2344 ............................... 189
MN6110 ................. 63-2632 ...............................413 PV300 .................... 62-3093 ............................... 273
L480 .......................60-2203 ............................... 362
MN6120 ................. 63-2588 ...............................415 PV400 .................... 62-3093 ............................... 273
L482 .......................74-3935 ............................... 362
MN6134 ................. 63-2588 ...............................417 PV500 .................... 62-3093 ............................... 273
L6006 .....................60-2104 ............................... 186
MN7220 ................. 63-2587 ...............................415 PV600 .................... 62-3093 ............................... 273
L6008 .....................60-2104 ............................... 188
MN7234 ................. 63-2587 ...............................417 PV800 .................... 62-3093 ............................... 273
L6081 .....................60-2105 ............................... 191
MN7505 ................. 63-2633 ...............................411 PVB .............................. ..................................... 342
L7224U............... 69-1720EFS............................ 199
MN7510 ................. 63-2633 ...............................413 PVL .............................. ..................................... 342
L8100 .....................60-2336 ............................... 190
MP516 ................... 75-1741 ...............................800 PVU075.................. 62-3069 ............................... 250
L8124 .....................60-2061 ............................... 193
MP909D................. 75-5506 ...............................801 PVU100.................. 62-3069 ............................... 250
L8148 .....................60-2278 ............................... 196
MP909E,H ............. 75-5506 ...............................803 PVU125.................. 62-3069 ............................... 250
L91 .........................60-2152 ............................... 965
MP913 ................... 95-7207 ...............................806 PVU150.................. 62-3069 ............................... 250
LCZ460-30-ECC 005886-2-EN ........................... 904
MP918A,B ............. 77-3080 ...............................807 PWT100 ................. 63-1327 ............................... 489
LP907.....................77-9231 ............................... 750
MP920 ................... 77-6087 ...............................809 PWT250 ................. 63-1327 ............................... 489
LP914.....................75-5527 ............................... 779
MP953C,D ............. 75-5500 ...............................812 PWT50 ................... 63-1327 ............................... 489
LP915.....................75-5527 ............................... 780
MP953E,F.............. 77-3001 ...............................813 PWT-BV ................. 63-2693 ............................... 489
LP916.....................75-5559 ............................... 751
MP958 ................... 95-7541 ...............................814
LP920.....................77-9873 ............................... 768
MS4103 ................. 63-1336 ...............................389 Q
MS4105 ................. 63-2607 ...............................392 Q100 ...................... 60-2135 .......................472, 930
M MS4110 ................. 63-2607 ...............................395 Q179A,B ................ 60-2032 ............................... 924
M4185 ....................63-2627 ............................... 449 MS4120 ................. 63-2607 ...............................398 Q179C,D ................ 60-2359 ............................... 925
M436 ......................60-2119 ............................... 470 MS4120F ............... 63-2584 ...............................423 Q181 ...................... 60-2124 ............................... 466
M6063 ................. 95C-10887 ............................. 223 MS4209F ............... 63-2578 ...............................421 Q209 ...................... 63-2226 ............................... 467
M6184 ....................63-2629 ............................... 451 MS4309F ............... 63-2578 ...............................421 Q270 ............................ ..................................... 975
M6194 ....................63-2188 ............................... 451 MS4620F ............... 63-2584 ...............................423 Q298 ...................... 60-2001 ............................... 472
M6274 ....................63-2629 ............................... 455 MS4709F ............... 63-2578 ...............................421 Q313 ...................... 60-2087 ............................... 128
M6284 ....................63-2629 .......................453, 455 MS4809F ............... 63-2578 ...............................421 Q314 ...................... 60-2075 ............................... 131
M6285 ....................63-2629 ............................... 454 MS7403 ................. 63-1336 ...............................389 Q3200 .................... 69-2334 ............................... 143
M6294 ....................63-2629 .......................453, 455 MS7405 ................. 63-1336 ...............................392 Q327 ...................... 60-2075 ............................... 132
M6410 ............ 62-0100, 63-2612 ....................... 680 MS7503 ................. 63-1336 ...............................389 Q340 ...................... 60-2087 ............................... 128
M6415 ....................63-2100 ............................... 441 MS7505 ................. 63-2607 ...............................392 Q345 ...................... 68-0094 ............................... 133
M6435 ....................62-0100 ............................... 681 MS7510 ................. 63-2607 ...............................395 Q347 ...................... 60-1018 ............................... 143
M7164 ....................63-2640 ............................... 456 MS7520 ................. 63-2607 ...............................398 Q354 ...................... 60-0033 ............................... 143
M7215 ....................63-2100 ............................... 441 MS8103 ................. 63-1336 ...............................389 Q390 ...................... 60-2087 ............................... 129
M7274 ......................... ...................................... 457 MS8105 ................. 63-1336 ...............................392 Q5001 .................... 63-2425 ............................... 474
M7284 ....................63-2640 ............................... 458 MS8110 ................. 63-1296 ...............................395 Q5020 .................... 63-2552 ............................... 475
M7285 ....................63-2640 ............................... 458 MS8120 ................. 63-2607 ...............................398 Q5022 .................... 62-3109 ............................... 476
M7286 ....................63-2640 ............................... 458 MS8120F ............... 63-4513 ...............................423 Q520 ............................ ..................................... 975
M7294 ....................63-2640 ............................... 458 MS8209F ............... 63-2578 ...............................421 Q605 ...................... 63-2263 ............................... 473
M7410 ............ 62-0100, 63-2612 ....................... 680 MS8309F ............... 63-2578 ...............................421 Q607 ...................... 60-2123 ............................... 467
M7415 ....................63-2100 ............................... 441 MT100,MT110 ....... 62-3022 ...............................268 Q624 ...................... 60-2049 ............................... 928
M7435 ....................62-0100 ............................... 681 MT4 Series .................. ......................................242 Q633 ...................... 60-2023 ............................... 156
M7685 ....................63-2640 ............................... 460 MV876 ................... 62-3061 ...............................295 Q651 ...................... 60-2016 ............................... 525
M8185 ....................63-2627 ............................... 449 MX Series .............. 62-3091 ...............................297 Q652 ...................... 63-2159 ............................... 929
M835 ......................60-2120 ............................... 470 MZV Series ............ 62-3099 ...............................238 Q667 ............................ ..................................... 356
M836 ......................60-2119 ............................... 470
Q7002 .................... 63-2551 ............................... 425
M8405 ....................63-2100 ............................... 441 N Q7130 .................... 63-2235 ............................... 469
M8415 ....................63-2100 ............................... 441
N05 Series ......63-2632, 63-2633 ........................411 Q7230 .................... 63-2235 ............................... 469
M847 ................... 95C-10190 ............................. 471
N10 Series ......63-2633, 63-2633 ........................413 Q7330 .................... 63-2235 ............................... 469
M847D................. 95C-10190 ............................... 53
N20 Series ............. 63-2588 ...............................415 Q769A .................... 62-0071 ............................... 442
M9164 ....................63-2631 ............................... 462
N34 Series ......63-2587, 63-2588 ........................417 Q769B .................... 63-2455 ............................... 442
M9174 ....................63-2631 ............................... 462
NXBJ ..................... 62-0303 ...............................709 Q769C.................... 63-2463 ............................... 442
M9175 ....................63-2631 ............................... 463
NXL........................ 63-1319 ...............................708 Q7740 .................... 74-2858 ............................... 306
M9182 ....................63-2631 ............................... 461
NXL.................63-1319, 62-0303 ........................701 Q7750 .................... 74-2950 ............................... 306
M9184 ....................63-2631 ............................... 462
NXP ....................... 63-1319 ...............................704 Q7751A .................. 95-7510 ............................... 306
M9185 ....................63-2631 ............................... 463
NXS ....................... 63-1319 ...............................705 Q7751F ........................ ..................................... 306
M9194 ....................63-2631 ............................... 462
Q7751G ....................... ..................................... 306
M9484D,E,F ...........63-2190 ............................... 930
M9494D,F ..............63-2190 ............................... 930 P Q7751H.................. 74-3963 ............................... 306
P643 ...................... 77-9269 ...............................793 Q7751J .................. 63-4514 ............................... 306
MARD.....................69-1551 ................................. 48
P658 ...................... 75-7151 ...............................794 Q7752B .................. 74-3067 ............................... 307
MF020 .................... 000670 ................................ 906
P7640 .................... 63-1306 ...............................488 Q7752C.................. 63-2630 ............................... 307
ML4115 ..................63-2540 ............................... 419
P7810 .................... 65-0285 ...............................967 Q7770 .................... 95-7700 ............................... 348
ML4125 ..................63-2567 ............................... 403
P906 ...................... 60-2155 ...............................361 Q7800 .................... 65-0084 ............................... 885
ML4135 ..................63-2567 ............................... 401
Q795 ...................... 65-0042 ............................... 975

iv customer.honeywell.com 70-6910
Model Number Index
Q7999A ..................65-0240 ............................... 900 RP972.................... 77-9831 ...............................789 T4031A .................. 60-2177 ............................... 363
QM4520A ...............65-0211 ............................... 907 RP973.................... 77-9847 ...............................790 T4031C .................. 63-2035 ............................... 365
QS460MMDS .........69-2377 ............................... 907 RP975.................... 77-9846 ...............................791 T4039..................... 60-2241 ............................... 516
QS7100D .................... ...................................... 179 RRD..................... 69-1960ES ...............................48 T4054..................... 60-2173 ............................... 367
QS7100T .................... ...................................... 179 T410.....................68-0145EF ................................ 3
S T4398..................... 69-1604 ................................... 5
R S03 Series ............. 63-1336 ...............................389 T451.....................95C-10903 ............................ 522
R182.......................60-2481 ............................... 214 S05 Series ............. 63-2607 ...............................392 T475....................... 60-2219 ............................... 976
R24.........................63-9578 ............................... 156 S10 Series ............. 63-2607 ...............................395 T498.....................95C-10686 ................................ 4
R4222.....................60-2056 ............................... 157 S20 Series ............. 63-2607 ...............................398 T6031A .................. 60-2177 ............................... 363
R4225.....................60-2165 ............................... 158 S437 ...................... 60-2186 ...............................364 T6031C,D,F ........... 63-2035 ............................... 365
R4795.....................60-2285 ............................... 972 S443 ...................... 60-2122 ...............................468 T6031E .................. 63-2118 ............................... 366
R7140.....................66-1153 ............................... 884 S445A.................... 60-1209 ...............................983 T6051..................... 63-1093 ............................... 523
R7184.....................69-1459 ............................... 176 S483 ............................ ........................................25 T6052..................... 63-1093 ............................... 523
R7247 ......................... ...................................... 909 S637 ...................... 60-2186 ...............................364 T6054..................... 60-2173 ............................... 368
R7248 ......................... ...................................... 909 S688 ...................... 60-2103 .................................99 T6069...................95C-10678 ............................ 517
R7249 ......................... ...................................... 909 S7760 .................... 74-2972 ...............................350 T6169...................95C-10679 ............................ 518
R7258 ......................... ...................................... 910 S7800 .................... 65-0090 ...............................887 T631A,B,C ............. 60-2214 ............................... 369
R7259 ......................... ...................................... 910 S7800A1142.......... 65-0288 ...............................888 T631F,G................. 60-2509 ............................... 370
R7289 ......................... ...................................... 910 S7810A.................. 65-0091 ...............................889 T651.....................95C-10903 ............................ 522
R7290 ......................... ...................................... 910 S7810B.................. 65-0228 ...............................889 T675A,B ................. 60-2200 ............................... 371
R7476.....................95-8270 ............................... 909 S7810M ................. 65-0249 ...............................890 T675F..................... 60-2213 ............................... 373
R7795.....................66-2001 .......................970, 972 S7820 .................... 65-0095 ...............................890 T678A .................... 60-2200 ............................... 371
R7910A ..................65-0310 ............................... 894 S7830 .................... 65-0101 ...............................891 T678B .................... 60-2207 ............................... 977
R7911A ..................66-1174 ............................... 895 S7910 ............. 66-1175, 68-0295 ........................896 T678C,E,F.............. 60-2215 ............................... 374
R7999A ..................65-0238 ............................... 899 S7999B.................. 65-0283 ...................... 897, 900 T7022A .................. 60-0247 ............................... 498
R8182.....................68-0105 ............................... 200 S7999C.................. 65-0303 ...............................898 T7047..................... 60-2174 ............................... 499
R8184G..................69-0618 ............................... 177 S8610U.................. 68-0135 ...............................138 T7067..................... 60-2421 ............................... 356
R8184M..................68-0111 ............................... 177 S87 ........................ 68-0039 ...............................136 T7079..................... 63-2572 ............................... 375
R8222.....................60-2056 ............................... 157 S8910 .................... 68-0161 ...............................139 T7080..................... 60-2527 ............................... 357
R8225.....................60-2165 ............................... 158 S89C...................... 68-0070 ...............................137 T7147..................... 63-4065 ............................... 500
R8228.....................60-2056 ............................... 157 S89E...................... 68-0066 ...............................137 T7350..................... 63-2605 ............................... 534
R8229.....................60-0581 ............................... 159 S89F ...................... 68-0066 ...............................137 T7350,Y7355 ......... 63-2605 ............................... 538
R8239.....................60-2023 ............................... 166 S900 ............................ ......................................904 T7351F................... 63-9630 ............................... 535
R8246.....................60-0581 ............................... 152 S963B.................... 60-2122 ...............................360 T7560..................... 74-3097 ............................... 501
R8285.....................68-0088 ............................... 166 S963D.................... 60-2463 ...............................360 T7750..................... 74-2944 ............................... 504
R8330D ..................60-0327 ............................... 160 SCV ............................. ......................................256 T775A,B,M,R ......... 63-1318 ............................... 376
R841................... 95C-10090B ........................... 160 SEC-ENC-H........... 95-7747 ...............................337 T775L,P,S,U .......... 63-1318 ............................... 378
R845.......................60-2481 ............................... 216 SEC-H-201 ............ 74-5081 ...............................330 T775-SENS............ 63-7147 ............................... 502
R847.......................60-2481 ............................... 215 SEC-H-600 ............ 74-5081 ...............................330 T7771..................... 63-2617 ............................... 504
R856.......................60-2171 ............................... 214 SEC-H-INT-KP ............ ......................................335 T8034..................69-1967EFS ............................. 23
R8845U ..................68-0215 ............................... 217 SEC-H-R2R ........... 95-7749 ...............................331 T812....................69-1606ESF ............................. 24
RA116 ....................68-0119 ............................... 178 SEC-H-RIO............ 74-4060 ...............................331 T822K .................69-1967EFS ............................. 22
RA117 ....................68-0119 ............................... 178 SNDJ-CNT......... 009558-1-EN ...........................904 T822L..................69-1967EFS ............................. 22
RA832 ....................60-2481 ............................... 216 SP470.................. 95-7236EF .............................796 T827K .................69-1967EFS ............................. 23
RA889A..................68-0216 ............................... 219 SP970.................... 77-9845 ...............................797 T834....................69-1967EFS ............................. 23
RA89 ......................60-2481 ............................... 216 SPRD..................... 69-1518 .................................49 T8775..................... 68-0279 ................................. 20
RA890 ....................60-2034 ............................... 969 SS-810-1-12BT ........... ......................................906 T87K,N................69-1864EFS ............................. 21
RA890F ..................60-2034 ............................... 973 ST6008 .................. 68-3002 ...............................541 T915....................... 60-2201 ............................... 379
RA890G .................60-2035 ............................... 974 ST71 ............................ ......................................974 T921....................... 60-2242 ............................... 526
RAM Series ............62-3102 ............................... 240 ST7800 .................. 65-0089 ...............................892 T991A .................... 60-2196 ............................... 380
REM5000 ........... 69-2055EFS ............................. 33 ST795 .......................... ......................................974 T991B .................... 63-1102 ............................... 977
RM Series ..............62-3093 ............................... 241 ST82D ................... 69-0488 ...............................161 T991E,F ................. 60-2176 ............................... 978
RM7800..................66-2028 .......................867, 868 ST9103 .................. 69-0686 ...............................145 TAX Series ................... ..................................... 275
RM7823..................66-2031 ............................... 869 ST9120 ................ 69-2252EF .............................145 TAXV Series .......... 62-3081 ............................... 276
RM7824..................65-0155 ............................... 870 SUB208,SUB480 ........ ......................................510 TAZ ........................ 69-1366 ................................. 41
RM7830..................66-2041 ............................... 866 SUB2120,SUB3208 .... ......................................509 TB6575 .................. 63-1323 ............................... 519
RM7838A ...............66-2029 ............................... 871 SUBAC,SUBM ............. ......................................511 TB6980 .................. 62-0238 ............................... 527
RM7838B,C............66-1094 ............................... 872 SV173.................... 63-9479 ...............................251 TB7100 .................. 63-2675 .........................11, 533
RM7838B,C............66-2036 ............................... 873 SV175.................... 63-9479 ...............................251 TB7220 .................. 63-2635 .........................10, 532
RM7840..................66-2027 .......................874, 875 SV9501.................. 69-1270 ...............................117 TB7980 ........................ ..................................... 527
RM7845..................66-1147 ............................... 876 SV9502.................. 69-1270 ...............................117 TB8220 .................. 63-2625 ...........................8, 531
RM7850..................66-2041 ............................... 866 SV9510.................. 69-2014 ...............................118 TB8575 .................. 63-1323 ............................... 519
RM7885..................66-2035 ............................... 876 SV9520.................. 69-2014 ...............................119 TD-090 ......................... ..................................... 255
RM7888..................65-0175 ............................... 877 SV9541.................. 69-2012 ...............................120 TD-165 ......................... ..................................... 255
RM7890..................65-0179 ............................... 878 SV9601.................. 69-1270 ...............................121 TDV-040 ...................... ..................................... 255
RM7890..................66-2032 ............................... 879 SV9602.................. 69-1270 ...............................122 TG510 .......................... ....................................... 39
RM7895..................66-2026 .......................880, 971 SV9641.................. 69-2012 ...............................123 TG511 .................... 68-0104 ................................. 39
RM7896..................66-2026 ............................... 881 SXB35 ................... 63-1339 ...............................513 TG512 .................... 68-0104 ................................. 40
RM7897..................66-1151 ............................... 882 SXB36 ................... 63-1339 ...............................513 TH1100 ...............69-1968EFS ............................. 19
RM7898..................RM7898 ............................... 883 SXB40 ................... 63-1340 ...............................514 TH1110 ...............69-1968EFS ............................. 19
RP418 ....................85-0065 ............................... 782 SXB50 ................... 63-1340 ...............................514 TH1210 ...............69-1968EFS ............................. 19
RP470 ....................77-9852 ............................... 783 SXBC-1.................. 63-1342 ...............................515 TH2110 ...............69-1968EFS ............................. 14
RP471 ....................77-9848 ............................... 784 SXBC-5.................. 63-1342 ...............................515 TH2210 ...............69-1968EFS ............................. 14
RP670 ....................77-9848 ............................... 785 SymmetrE.............. 63-4515 ...............................300 TH3110 ...............69-1929EFS ............................. 18
RP7517 ..................77-5014 ............................... 765 TH3210 ...............69-1929EFS ............................. 18
RP818 ....................85-0065 ............................... 782 T TH4110 ...............69-1928EFS ............................. 14
RP913 ....................77-9378 ............................... 786 TH4210 ...............69-1928EFS ............................. 14
T100 ...................... 62-3048 ...............................269
RP922 ....................77-5053 ............................... 786 TH5110 ...............69-1922EFS ............................. 17
T100R.................. 95C-10712 .............................260
RP970 ....................77-9850 ............................... 787 TH5220 ...............69-1922EFS ............................. 17
T104 ...................... 62-3004 ...............................271
RP971 ....................77-9849 ............................... 788 TH5320 ...............69-1922EFS ................ 17, 31, 36

70-6910 v
Model Number Index
TH6110 .............. 69-1920EFS.............................. 13 V5197 .................... 65-0247 ...............................938 W7213.................... 63-2596 .......................435, 437
TH6220 .............. 69-1920EFS.............................. 13 V5306 .................... 60-2307 ...............................102 W7214.................... 63-2596 ............................... 437
TH6320 .............. 69-1920EFS........................13, 31 V5442N................ 95C-10888 .............................222 W7215.................... 63-2544 .......................435, 438
TH8110 ..................68-0280 ................................... 9 V5852 .................... 62-0100 ...............................663 W7350.................... 63-2658 ............................... 539
TH8320 ..................68-0280 ................................... 9 V5853 .................... 62-0100 ...............................665 W7350A ................. 62-0270 ............................... 345
TH8321 ..................68-0280 ................................... 9 V5862 .................... 63-2612 ...............................663 W7459.................... 63-2684 .......................435, 439
TH9421 ..................68-0287 .............................7, 35 V5863 .................... 63-2612 ...............................665 W7460.................... 63-2544 ............................... 438
THM4000 ........... 69-2095EFS.............................. 32 V800 ...................... 95-6996 ...............................101 W7460.....................W7460 ................................ 435
THM5320 ........... 69-2091EFS.............................. 32 V8043 .................95C-10938B .. 229, 230, 231, 232 W7499.................... 63-2684 ............................... 439
THM5421 ........... 69-1816EFS..........................7, 35 V8044 .................... 60-2133 ...............................233 W7750.................... 74-2956 ............................... 351
THX9321 ............ 69-2053EFS..........................6, 26 V8046C.................. 66-2008 ...............................952 W7751............ 74-2940, 74-2942 ....................... 352
TK300.....................62-3080 ............................... 257 V8295 .................... 65-0194 ...............................953 W7752.................... 74-2959 ............................... 353
TK300-30A .................. ...................................... 259 V88A ...................... 60-2080 ...............................931 W7753.................... 74-2962 ............................... 354
TK30PV ....................... ...................................... 258 V88J ...................... 60-2080 ...............................932 W7760A ................. 74-2967 ............................... 349
TK60PV ....................... ...................................... 258 V8943A ........................ ......................................933 W7760B ................. 74-3472 ............................... 349
TL Series ................62-3081 ............................... 277 V8943B,C,N........... 65-0214 ...............................934 W7760C ................. 74-3080 ............................... 350
TL6120 ................ 69-1904EF ................................. 3 V8944B,C,L,N........ 65-0214 ...............................935 W7761.................... 74-2698 ............................... 354
TL7130A.................69-1807 ................................... 2 V9055 .................... 60-2311 ...................... 939, 944 W7762.................... 74-2934 ............................... 355
TL7235A.................69-1802 ................................... 2 VBF2...................... 63-2649 ...................... 566, 567 W7763.................... 74-2989 ............................... 355
TL8100 ................ 69-2018ES ................................. 1 VBF3...................... 63-2649 ...................... 566, 571 W8150.................... 68-0282 ................................. 97
TL8130A............. 69-1804EFS................................ 1 VBN2 ..................... 63-2648 ...................... 566, 575 W859...................... 63-2476 ............................... 440
TL8230A............. 69-1804EFS................................ 1 VBN3 ..................... 63-2648 ...................... 566, 593 W8600A ...............69-1448EF............................... 75
TP9600...................74-5594 ............................... 753 VC Series .. 95C-10646, 95C-10647 ...................224 W8703.................... 68-3045 ................................. 45
TP970.....................77-1003 ............................... 754 VC2...................... 95C-10920 .............................682 W8703A ................. 68-3045 ................................. 45
TP971.....................77-9824 ............................... 756 VC4...................... 95C-10920 .............................682 W8735A ................. 68-3063 ................................. 45
TP972.....................77-9825 ............................... 758 VC6936................ 95C-10909 .................... 675, 684 W8735D ................. 68-3065 ................................. 37
TP973.....................77-9826 ............................... 759 VC7936................ 95C-10904 .............................675 W8735S ................. 69-2335 ............................... 201
TP974.....................77-9827 ............................... 781 VC8...................... 95C-10920 .............................682 W8835..................68-0258ES .............................. 44
TP975.....................95-7152 ............................... 760 VCZA ................... 95C-10948 .............................668 W9076.................... 63-2093 ............................... 359
TR20 Series ........ 63-1321ES............................. 505 VCZB ................... 95C-10948 .............................668 W973...................... 60-2428 ............................... 360
TR20 Series ...........63-1332 .......................506, 507 VCZM .................. 95C-10948 .............................672 WC2003 ................. 74-4016 .......................338, 339
TR70 ......................63-1322 ............................... 508 VCZN ................... 95C-10948 .............................672 WEB 403 R2 ................ ..................................... 338
TRN Series ................. ........................................ 73 VF270 .......................... ......................................296 WEB-201................ 74-4035 ............................... 317
TS812................. 69-1606ESF.............................. 24 VFF1 ...................... 63-2661 ...............................601 WEB-403................ 74-4027 ............................... 319
TX Series ...............62-3082 .............. 256, 274, 278 VFF1 ......................63-2661t ...............................602 WEB-545................ 74-4028 ............................... 320
VFF2 ...................... 63-2661 ...................... 601, 606 WEB-5R ....................... ..................................... 321
U VFF3 ...................... 63-2661 ...................... 601, 618 WEB-600................ 74-4067 ............................... 317
UC10 ........................... ........................................ 92 VFF6 ...................... 63-2661 ...................... 601, 629 WEB-NXS .............. 74-4066 ............................... 322
UC100 ....................69-1444 ................................. 92 VGF2 ..................... 63-2618 ...............................641 WEB-NXS-R2 .............. ..................................... 339
UC18 ........................... ........................................ 92 VGF3 ..................... 63-2618 ...............................646 WEBs-AX ............... 74-5081 ............................... 330
UC36 ........................... ........................................ 92 VP512 .................... 75-1785 ...............................817 WSK-24.................. 63-4519 ............................... 520
UEC24014 .................. ...................................... 777 VP513 .................... 75-1707 ...............................819 WWS-VL1A ............ 62-0319 ............................... 345
UMV Series ............62-3092 ............................... 287 VP519 .................... 75-2510 ...............................821
UV100 ................ 68-0297EFS.............................. 90 VP522 .................... 75-2598 ...............................822 X
VP525C ............... 75-5544EF .............................824 XCL .............................. ..................................... 302
V VP526 .................... 75-5547 ...............................826 XF ................................ ..................................... 302
VP527 .................... 75-5555 ...............................828 XFC ........................ 74-3671 ............................... 305
V110 .......................62-3004 ............................... 261
VP531C ............... 75-7251EF .............................830 XFL821A ................ 63-1326 ............................... 303
V135 .................... 95C-10711 ............................. 260
VR4300.................. 69-0683 ...............................103 XFL822A ................ 63-1326 ............................... 303
V200 .......................62-3056 ............................... 263
VR4304.................. 69-0838 ...............................106 XFL824A ................ 63-1326 ............................... 303
V2000 Series..........62-3056 .......................263, 267
VR4305.................. 69-0696 ...............................110 XFR822 ........................ ..................................... 303
V2042H ....................... ...................................... 266
VR8200.................. 68-0046 ...............................104 XFR824 ........................ ..................................... 303
V2043H ....................... ...................................... 266
VR8204.................. 68-0047 ...............................107 XIO ......................... 74-4043 ............................... 305
V400 .......................95-6996 ............................... 101
VR8205.................. 68-0049 ...............................111 XL100 .......................... ..................................... 304
V4043.....................60-2133 .......................225, 227
VR8245.................. 69-2013 ...............................108 XL50 ............................ ..................................... 304
V4044.....................60-2133 ............................... 228
VR8300.................. 68-0107 ...............................105 XPS Series............. 62-3080 ............................... 279
V4046A,B ...............60-2145 ............................... 181
VR8304.................. 68-0108 ...............................109
V4046C ..................66-2008 ............................... 952
VR8305.................. 68-0109 ...............................112 Y
V4055A,B,D,E ........60-2309 .......................939, 940
VR8345.................. 69-2013 ...............................113
V4055F,G ...............65-0029 .......................939, 942 Y496,Y896 ......... 69-2029EFS ........................... 234
VRN2 ..................... 62-3115 ...............................542
V4062.....................60-2099 .......................939, 943 Y7751..................... 74-2942 ............................... 355
VRW2 .................... 62-3116 ...............................564
V4295.....................65-0194 ............................... 953 Y8150..................... 68-0282 ................................. 97
VS820 .................95C-10024B ............................114
V4297A ..................65-0246 ............................... 954 Y8610U .................. 68-0291 ............................... 139
VU443.................. 95C-10885 .............................685
V4297S ..................65-0244 ............................... 955 Y8835...................68-0258ES .............................. 44
VU444.................. 95C-10885 .............................685
V48A ......................60-2080 ............................... 931 YHZ322 .................. 69-2041 ................................. 42
VU52.................... 95C-10884 .............................678
V4943A ..................65-0212 ............................... 933 YHZ432 .................. 69-2041 ................................. 41
VU53.................... 95C-10884 .............................678
V4943B,N ...............65-0214 ............................... 934 YP900 .................... 66-1190 ............................... 903
VU54.................... 95C-10884 .............................679
V4944.....................65-0214 ............................... 935 YTH5320 ............ 69-2091EFS ... 16, 27, 28, 29, 30
VU843.................. 95C-10885 .............................685
V5011.....................60-2126 .......................654, 655 YTH6320 ............ 69-2091EFS ... 12, 27, 28, 29, 30
VU844.................. 95C-10885 .............................685
V5011A,B ...............60-2126 ............................... 640 YTH9421 ................ 68-0287 .............................7, 35
V5011F,G ...............60-2126 ............................... 648 YTHX9321 ......... 69-2053EFS .........................6, 26
V5011N ..................63-2548 .......................650, 659 W
V5013.....................63-2549 .......................654, 655 W136 ..................... 60-2179 ...............................982 Z
V5013B,C ...............60-2129 ............................... 644 W7080 ................... 63-4179 ...............................357
ZD .......................... 68-0247 ................................. 50
V5013N ..................63-2549 .......................652, 660 W7081 ................... 60-2512 ...............................358
ZL7751A ................. 4-3449 ................................ 348
V5047A .................71-92128 .............................. 661 W7100A,C ............. 60-2507 ...............................358
ZL7760A ........ 74-2937, 74-3961 ....................... 347
V5051A ..................60-2130 ............................... 662 W7100G ................ 63-4046 ...............................359
ZL7762A ................ 74-3960 ............................... 347
V5055.....................60-2307 .......................939, 946 W7101 ................... 63-2119 ...............................927
ZM7999A ............... 65-0242 ............................... 902
V5097.....................65-0230 .......................939, 949 W7210 ................... 63-2528 ...................... 435, 436
V51 .........................60-2102 ............................... 937 W7212 ................... 63-2596 ...................... 435, 437

vi customer.honeywell.com 70-6910
Subject Index
Numerics TrueDRY 77–78 Whole House 67
7800 SERIES 845–893 TrueSTEAM 79 Air Conditioning Controls
Accessories 893 V5011 and V5013 Globe Valves 654 Classroom Training 990
Communications interface 889 V5055/V5097 Industrial Gas Valves 951 Air Eliminators 247–251
ControlBus Module 889 Variable Frequency Drives 746 Commercial 273
Expanded Annunciator 891 Ventilation Systems 98 GoldTop 247
Flame Amplifiers 908–909 Water Filters 295 Heating or cooling systems 247, 248, 251
Keyboard Display 887, 888 WEBs-AX Controllers 318 Heating systems 249, 250
ModBus Module 890 Wireless Occupancy Solution 521 Hot water or Steam 247
Network Interface 907 Zone Control Panel 46 Hygrovent 247
Primary Control Modernization 971 Actuator and Valve Assemblies 542–565, 567–600, Installation 250
Purge Timers 892 602–639, 675–676 MaxiVent 248
Relay Modules 845–883 Actuators SuperVent 249, 250, 251
Reset Module 890 ControLinks Top vent 251
Testers and Demonstrators 979 Accessories 902 Air Purger 248, 259
Wiring Subbase 885–886 Direct Coupled 901 Air Treatment System
Universal 901 Ultraviolet 90–92
A Dampers 355, 470–471 Replacement Lamps 92
Accessories 907 Accessories 425–434 Air Vents 244–246
7800 SERIES 893 Fire and Smoke applications 419–424 Accessories 246
Air Cleaners 74–75 Non-Spring Return 405–418 Heating Systems 245
Air Vents 246 Pneumatic 799–811 Industrial 244
AQUATROL Zoning System 211 Accessories 810–811 Potable systems 246
Burner Controls 893 Proportional Control 801–809 Replacement Parts 246
Cartridge Cage Valves 677 Replacement Parts 810–811 Airstat Fan Safety Cutoff Controllers 185
Cartridge Globe Valves 667 Torque Ratings 799 AIRWATCH 75
Combination Gas Controls 126–127 Unit Ventilator 800 Alarm
Commercial Mixing Valves 298 Residential 53 Carbon Monoxide 100
Commercial Thermostats 537 Spring Return 389–404 AM-1 Series Valves 281–283
ControLinks Actuator 902 Fast Acting 401–404, 419–424 Amplifiers
ControLinks Fuel Air Control System 902 Delphi Combustion System 903 Flame 908–910
Damper and Valve Linkages 473, 474, 477 Economizers 439, 441–442 Accessories 910
Delphi Combustion System 904 Accessories 442 AMX Series 284–285
Diaphragm Gas Valves 936 Fluid Power 939–945 AMX300 Series 286
Direct Coupled Damper Actuators 425–434 Accessories 945 Annunciator 907
Direct Coupled Valve Actuators 692 Manual Reset Safety Shut-Off 942 Approval agencies xvii
Economizer Actuators 442 Modulating 944–945 Aquastat Controllers 186–201
Economizer Logic Modules 440 Off-Lo-Hi 943–944 Electronic 199
Environmental Control Systems 360 On-Off 940–941 High Limit 189
Excel 5000 System 307–311 Replacement Parts 945 Oil 189, 191, 199
Fan and Limit Controllers 185 Selection Chart 939 Relay 196
Fan Coil Thermostats 518 Gas Valves 939–945 Remote Bulb 188
Fan Coil Valve Actuators 686 Accessories 945 Replacement Parts 201
Flame Amplifiers 910 Manual Reset Safety Shut-Off 942 Triple Relay 193
Flame Detectors 923 Modulating 944–945 Water Heaters 190
Flame Rods 912 Off-Lo-Hi 943–944 AQUATROL Zoning System 203–213
Fluid Actuators 945 On-Off 940–941 Accessories 211
Globe Valves 653 Replacement Parts 945 Boiler Reset Control Panel 205, 207
Ignition Transformers 929 Selection Chart 939 Relay Control Panel 203, 204
Kit Mounted Motors 471 Globe Valves 687–689 Replacement Control Modules 210
Line Voltage Thermostats 524 Herculine 903 Replacement Parts 211
LonWorks Bus 306–307 Radiator Valve Operators 260–272 Replacement Zoning Modules 210
Magnetic Valves 181 Accessories 272 Sensors 211
Manifold Zone Valves 242 High Capacity 271–272 Zoning Expansion Panel 208, 209
Mixing Valves 283 Mixing or Diverting Valves 260 Auxiliary Potentiometer 466
Modutrol IV Motors 464–469 Replacement Parts 272 Auxiliary Switches
Network Interface 907 Standard Capacity 269–270 Contactors 152
Pilot Burners Residential Heating 222–224 B
Commercial 926 Valves 680–692
Residential 134 Backflow Preventers 253
Cartridge Globe 680–681 Installation 253
Pneumatic Controls 835–841 Fan Coil 685–686
Pneumatic Damper Actuators 810–811 Backwash Controls 295
Pneumatic 812–816 Ball Valves 566–600
Pneumatic Humidistats 749 Accessories 816
Pneumatic Pressure Controllers 777 Flanged 567–574
Cartridge Globe Valves 814 Threaded 575–600
Pneumatic Relays 791 Replacement Parts 816
Pneumatic Temperature Controllers 771 Three-way 571–574, 593–600
VC Series 682–684 Two-way 567–570, 575–592
Pneumatic Temperature Sensors 781 Fail Safe Proportional 684
Pneumatic Thermostats 761–762 Bathroom Fan Control 97
Proportional 683 Boiler Fill Valves 254
Pneumatic Valve Actuators 816 Two-position 682
Pneumatic Valves 831–832 Building Automation Appliances 344–345
Advanced Burner Controls 905–906 Burner and Boiler Controls
Pneumatic Velocity Sensor/Controller 767 Oxygen Sensor 906
Pressure and Limit Controls 968 Training Booklets 986
Agricultural Temperature Controllers 365–366, Burner Controls 905–906
Pressure Regulating Valves 291 369–370, 373
Proportional Thermostats 526 Accessories 893
Air Cleaners Communications interface 889
Relays 162 Accessories 74–75
Remote Bulb Temperature Controllers 382 ControlBus Module 889
Electronic 59–63 Electromechanical 972–975
Remote Temperature Controllers 383 Replacement Parts 62
Residential Thermostats 38–40 Flame Amplifiers 975
Return Grille 64 Primary Control 972–974
SmartVFD Compact 694 Replacement Filters 71
SOLA Controllers 898 Purge Timers 974
Replacement Parts 66 Wiring Subbase 975
Solenoid Gas Valves 955 HEPA 67, 68
Spyder Controllers 343 European Community Timings 865, 866
Media 55–58 Expanded Annunciator 891
Temperature Sensors 491, 494, 499 Replacement Filters 69–70, 73
Thermocouples and Thermopiles 129 Flame Switch 869
Replacement Filter 75 Integrated 864
Thermostatic Radiator Valve Operators 272 Replacement Parts 74–75
Thermostatic Radiator Valves 267–268 Keyboard Display 887, 888
Replacement Power Supply 76 Microprocessor 864–893

70-6910 vii
Subject Index
ModBus Module 890 Compact I/O 305 SOLA 894–895
Oxygen Sensor 906 Contactors 146–155 Accessories 898
Primary Controls 870, 879 1 pole 147, 151 Hydronic 894
Manual Start 876 2 pole 148, 151 Keyboard Display 896
PLC Adaptable 877 3 pole 149 Local Operator Interface 898
with Post-Purge 882 4 pole 150 Program Module 898
with Pre and Post-Purge 881 Auxiliary Switches 152 Replacement Parts 898
with Prepurge 880 Definite Purpose 146–155 Steam 895
with Purge, Manual Start 871 1 pole 147 System Operator Interface 897
Programmers 874, 876, 884 2 pole 148 Spyder 342–343
Manual Start 872 3 pole 149 Temperature Sensors 505
Purge Timers 4 pole 150 Static Pressure
Microprocessor Burner Controls 892 Economy 151–155 Pneumatic 774–775
Reset Module 890 1 pole 151 Temperature 365–383
Wiring Subbase 885–886 2 pole 151 Accessories 382, 383
With VPS 868, 873, 875, 878, 883, 888 Electric Heat 152 Agricultural 365–366, 369–370, 373
Butterfly Control Valves 601–639 Selection Guide 155 Discharge Air 358
Butterfly Gas Valves 937–938 Order Number Guide 146 Discharge Water 359
Integrated Train 938 Selection Guide 153 Line Voltage 367, 368
Butterfly Valves 601–639 Control Ball Valves 566–600 Pneumatic 768–771
Accessories 639 ControlBus Module 889 Accessories 771
Gas 937–938 ControLinks Fuel Air Control System 899–902 Replacement Parts 771
Gas or Air 937 Accessories 902 Proportional 769–770
Replacement Parts 937 Actuator Accessories 902 Remote Bulb 371–372, 768
Integrated Train 938 Controller 899 Remote mounting 375, 376, 379–380
Three-way 618–639 Demonstrator 980 Remote sensing 378
Two-way 602–617 Direct Coupled Actuator 901 Remote Sensors 769–770
Bypass Humidifiers 81–83 Portable Combustion Analyzer 902 Replacement Parts 383
Replacement Parts 83 System Configuration Software 902 Reset 976–978
C System Display 900 Dual Bulb 977
Cad Cell Tester 179 Universal Actuator 901 Outdoor 976, 977
Cadmium Sulfide Flame Detectors 180 Wiring Subbase 900 Proportional 978
Cage Valves 662 ControLinks Fuel Air Ration System Return Air 367
Canadian Standards Association xvii Configuration Kit 995 Sensors 502–503
Carbon Dioxide (CO2) Sensors 478–479 Demonstrator 995 Type definition xvi
Carbon Monoxide Alarm 100 Display Demo 995 Unit Vent 354
Cartridge Cage Valves 668–677 Controllers VAV Unit 352, 355
Accessories 677 Airstat Fan Safety Cutoff 185 WEBs R2 System 338–339
Replacement Cartridges 677 Aquastats 186–201 WEBs-AX 319–322
Three-way 672–673 Electronic 199 WEBs-AX Security 330
Two-way 668–671 High Limit 189 WEBs-AX Suite 317–318
Cartridge Globe Valve Actuators 680–681 Oil 189, 191, 199 Accessories 318
Cartridge Globe Valves 663–667 Relay 196 WebStat 345
Accessories 667 Remote Bulb 188 WebVision 345
Replacement Parts 667 Replacement Parts 201 Controls
Three-way 665–667 Triple Relay 193 Pneumatic 747–844
Two-way 663–664 Water Heaters 190 Conversion factors xx
Cartridge replacement tool for Thermostatic Radiator Commercial Hydronic 927 Conversion of pressure units xix
Valves 268 ControLinks Fuel Air System 899 Cover Assemblies
CE Mark xvii CVAHU 351 Pneumatic Humidistats 749
Combination Gas Controls Differential Pressure 361 Pneumatic Thermostats 764
Accessories 126–127 Pneumatic 773, 777 Cross Reference
Continuous Pilot 103–106 Economizers 436 Commercial Thermostats 528–529
Direct Ignition 110–112 Enthalpy 436 Commercial Thermostats-Sensors 530
Intermittent Pilot 106–109 Excel 10 CP980 767
Millivoltage 114 Temperature Sensors 497, 504 Electric Heat Sequencer 165
Replacement Parts 126–127 Excel 100 304 Interface Module 469
SmartValves 117–125 Excel 15 349–350 Oil Primaries 175
Universal Electronic Ignition 113 Excel 50 304 Q3200 Igniter Bracket Replacement 142
Combustion System Excel 800 302 R8845U Replacement 218
Efficiency Panel 903 Fan and Limits 183–185 RA889A Replacement 220
Integrated 903–904 Accessories 185 T775 Series 377
Accessories 904 Fan Coil 353 Temperature Controllers 377
Actuators 903 for T7530 Thermostat 539 V2000 to V100 265
Replacement Parts 904 High Limit 183 Velocity Sensor Controller 767
Commercial Air Eliminators 273 Humidity 378 ZonePRO Thermostat 527
Commercial Expansion Tanks 274–279 Residential 88 Current Switches 480–482
Heating systems 275, 276, 277, 279 Hydronic 355 Current Transmitters 482
Large Capacity 274 Hydronic Heating 200 CVAHU Controllers 351
Potable Hot water systems 274, 278 Limit 358 D
Sizing 274 Pneumatic Velocity Sensor/Controller 766– Damper Actuators 355, 470–471
Commercial Hydronic Controllers 927 767 Accessories 425–434
Commercial Thermostats Accessories 767 Compatibility Chart 426
Cross Reference 528–529 Replacement Parts 767 Fast Acting 401–404, 419–424
Programmable 528–539 Pressure 378 Fire and Smoke applications 419–424
Accessories 537 Pneumatic 772–777 Non-Spring Return 405–418
Communicating 539 Pressure and Limits 960–968 Pneumatic 799–811
Resources 540 Accessories 968 Accessories 810–811
Commercial Thermostats-Sensors Limit Controller 963 Large dampers 807
Cross Reference 530 Line Voltage 967 Medium dampers 803, 807
Commercial/Industrial Combustion Oil Limit Controller 962 Proportional Control 801–809
Replacement parts 983 Pressuretrol® 960–963 Replacement Parts 810–811
Commercial/Industrial Combustion Testers and Proportional 965–966 Small dampers 801, 803
Demonstrators 979–982 Vaporstat® 964 Torque Ratings 799
CommercialPRO 10 Pressuretrol 182 Unit Ventilator 800
Communicating Thermostats 35–36 Refrigeration 362–364

viii customer.honeywell.com 70-6910


Subject Index
Residential 53 Logic Modules 436–440 Accessories 910
Spring Return 389–404 Demand Control Ventilation 437 BC7000 Series 909
Damper and Valve Linkages 472–477 Parts and Accessories 440 Electromechanical Burner Controls 975
Accessories 473, 474, 477 Motors R4140 909
Butterfly Valves 472 Linkages 472 R4795 910
Economizer Motors 472 Sensors 443–444 Flame Detectors 913–923
Modutrol IV Motors 474 Signal Adapters 442 Accessories 923
Modutrol Motors 473 Efficiency Panel 903 Adjustable Sensitivity 919
Tandem 476 Electric Furnace Sequencer 160 Cadmium Sulfide 180
Damper Motors 470 Electric Heat Contactors 152 Infrared 920
Dampers Selection Guide 155 Lead Sulfide 920
Airfoil 384 Electric Heat Controls Minipeeper 916–917
Rectangular 49–52 Classroom Training 990 Purple Peeper 913–915
Residential Zoning 47–53 Electric Heat Relays 159, 160 Replacement Parts 923
Accessories 53 Electric Heat Sequencer Residential 180
Round 47, 48, 387–388 Cross Reference 165 Self-Check 918, 921
Volume control 385 Selection Guide 164 Solid State 920
Data Acquisition Module 907 Electric Heat Thermostats 1–5 Ultraviolet 864, 913–921
Definite Purpose Contactors 146–155 Electromechanical Burner Controls 972–975 Visible light 922
1 pole 147, 151 Flame Amplifier Module 975 Flame Quality Monitor 179
2 pole 148, 151 Primary Control 972–974 Flame Rectification Sensor 143
3 pole 149 Modernization 970 Flame Rod Holders 911–912
4 pole 150 Purge Timers 974 Flame Rods 911–912
Definitions Tester 981 Accessories 912
Pneumatic 842–844 Wiring Subbase 975 Replacement Parts 912
Dehumidification 77–78, 80 Electronic Air Cleaners 59–63 Flame Safeguard Systems
Dehumidistats 89 Replacement parts 62 Product Selection Matrix 846–863
Delphi Combustion System 903–904 Return Grille 64 Flame Safeguard Textbook 992
Accessories 904 Replacement Filters 71 Flame Simulator 980
Actuators 903 Replacement parts 66 Float Valves 296
Efficiency Panel 903 Sail Switches 99 Floats 296
Replacement Parts 904 Electronic Fan Timers 145 Replacement Parts 296
Demand Control Ventilation 437 Energy Management Timers 541 Floor Sensor 211
Dew Point Sensors 483 Energy Recovery Ventilation Systems 93 FlowCheck Valves 252
Diaphragm Gas Valves 931–936 Replacement Parts 94 Fluid Power Actuators 939–945
Accessories 936 EnviraCOM™ enabled 37, 45 Accessories 945
High Temperature 932 EnviraZONE 44–45 Manual Reset Safety Shut-Off 942
On/Off 933 Environmental Control Systems Accessories 360 Modulating 944–945
Pressure Regulating 934–936 Excel 10 Controller Off-Lo-Hi 943–944
Replacement Parts 936 Temperature Sensors 497, 504 On-Off 940–941
Differential Pressure Regulators 243 Excel 15 Controller 349–350 Replacement Parts 945
Differential Pressure Switches 144 Display 350 Selection Chart 939
Digital Temperature Indicator 359 Excel 5000 System 299–311 FocusPRO 13, 17, 31, 36
Direct Coupled Actuators Accessories 307–311 Foot Mounted Motors 445–469
ControLinks 901 Architecture 299 Accessories 464–469
Dampers Excel 100 Controller 304 Auxiliary Potentiometer 466
Accessories 425–434 Excel 50 Controller 304 Auxiliary Switches 467
Fire and Smoke applications 419–424 Excel 800 Controller 302 Feedback 455
Non-Spring Return 405–418 Software 300 Interface Modules 469
Spring Return 389–404 Temperature Sensors 498, 501, 505 Internal Auxiliary Switch Kits 465
Fast Acting 401–404, 419–424 Excel Distributed I/O 303 Internal Transformers for Series 1 Motors 466
Valves 687–691 Expansion Panels Internal Transformers for Series 2 Motors 466
Accessories 692 AQUATROL 208, 209 Line Volt 449
Non-Spring Return 687, 688 F Low Volt 449
Spring Return 689 Factory Mutual xvii Manual Potentiometer 467, 468
Tandem Linkage 476 Fan and Limit Controllers 183–185 Non-Spring Return 454, 455, 456, 457, 458,
Direct Coupled Damper Actuators 389–434 Accessories 185 462
Direct Coupled Valve Actuators 687–691 Fan Centers 166–167 Slaving Applications 453, 454
DirectConnect Mixing Valves 284–285 Control Centers 166 Spring Return 449, 455, 457, 458, 461, 463
and Kits 286 Selection Guide 167 Freeze warning 25
Replacement Parts 286 Fan Coil 516–519 Fresh Air Ventilation Systems 97
Displays Thermostats 516–519 Fuel Air Control System 899–902
Excel 15 350 Accessories 518 Accessories 902
SOLA 896–898 Digital 519 Actuator Accessories 902
WEBs-AX 323 Replacement Parts 518 Controller 899
Distributors Valves 678–679 Direct Coupled Actuator 901
7800 Series xxiv Three-way 679 Portable Combustion Analyzer 902
Authorized Distributors xxiv Two-way 678 System Configuration Software 902
Authorized Systems xxiv Fan Coil Unit Controllers 353 System Display 900
Combustion Solutions xxiv Fan Coil Valve Actuators 685–686 Universal Actuator 901
Commercial Controls xxiv Fan Control 97 Wiring Subbase 900
ControLinks™ xxiv Fan Humidifiers 84–85 G
Drives Replacement Parts 85 Gas capacity ratings xix
Variable Frequency 693–746 Fan Manager 161 Gas Controls
DVD 985 Fan Relay 158 Training Booklets 986
Heating Controls 985 Filters Gas Ignition laboratory workstation 995
E Water 292–295 Gas Valves
Economizer Systems 985 Accessories 295 Butterfly 937, 937–938
Training DVD 985 High flow capacity 293 Integrated Train 938
Economizer Systems Quick Selection Guide 435 Replacement Parts 295 Replacement Parts 937
Economizers 435–444 Reversing 292 Combination Gas Controls
Actuators 439 Rinseable 294 Line Voltage 101
Controllers 436 Fireye Modernization 969 Low Voltage 101
Damper Actuators 441–442 Flame Amplifier Modules 975 Commercial
Accessories 442 Flame Amplifiers 864, 908–910 Diaphragm 931–936
Enthalpy Controller 436 7800 SERIES 908–909 Accessories 936

70-6910 ix
Subject Index
High Temperature 932 Hydronic heating 203–213, 241, 249, 250 Tandem 476
On/Off 933 Controllers 200 Load Analyzer 357
Pressure Regulating 934–936 Transformer 221 Logic Panel 360
Replacement Parts 936 Hydronic Switching Relays 214–220 LonWorks Bus Accessories 306–307
Industrial 946–951 Cross Reference 218, 220 LonWorks Bus Interface 348
Accessories 951 Heavy duty 215 M
Integrated Valve Train 949–951 Universal 217 Magnetic Valves 181
Pipe Adapters 950 Hydronic Zoning 203–213 Manifold Zone Valves 240–242
Replacement Parts 951 Add-a-Temperature Expansion Panel 208 Accessories 242
Linkages Boiler Reset Control Panel 205, 207 Pre-Assembled 240
Commercial 930 Expansion Panel 209 Replacement Parts 242
Pilot 952 Relay Control Panel 203, 204 Manual Potentiometer 467, 468
Residential Hygrovent 247 MaxiVent™ 248
Accessories 126–127 I Media Air Cleaners 55–58
Combination Gas Controls 101–116 Igniter Bracket Replacement Cross Reference 142 Replacement Filers 69–70
Pressure Regulators 102 Igniter Kit Perfect Fit 73
Continuous Pilot 103–106 Universal Hot Surface Igniter 143 Meter
Direct Ignition 110–112 Igniter, Spark 143 Commercial/Industrial Combustion 982
Intermittent Pilot 106–109 Igniter-Burner 133 Microprocessor Burner Controls 864–893
Millivoltage 114 Igniters and Sensors 143 Accessories 893
Replacement Parts 126–127 Ignition Modules Communications interface 889
Universal Electronic Ignition 113 Direct Spark 136, 137 ControlBus Module 889
SmartValves 117–125 Hot Surface 137 Expanded Annunciator 891
Solenoid 953–955 Universal Flame Switch 869
Accessories 955 Hot Surface 139 Industrial Programmers 873
Normally Open 955 Intermittent Pilot 138, 139 Keyboard Display 887, 888
Replacement Parts 955 Ignition Pilot Modules 136–140 ModBus Module 890
Safety Shut-off 954 Selection Guide 140 Primary Controls 865, 870, 878, 879, 883
Gas Valves Actuators 939–945 Ignition Transformers 928–929 Manual Start 876
Accessories 945 Accessories 929 Modernization 971
Manual Reset Safety Shut-Off 942 Replacement Parts 929 PLC Adaptable 877
Modulating 944–945 Indoor Air Quality 55–100 with Post-Purge 882
Off-Lo-Hi 943–944 Training Booklets 986 with Pre and Post-Purge 881
On-Off 940–941 Industrial Gas Valves 946–951 with Prepurge 880
Replacement Parts 945 Accessories 951 with Purge, Manual Start 871
Selection Chart 939 Integrated Valve Train 949–951 Programmers 867, 868, 874, 875, 876, 884
Gauges Pipe Adapters 950 Manual Start 872
Pneumatic Controls 834–835 Replacement Parts 951 Programming Control 866
Globe Valves 640–660, 661 Infrared Flame Detectors 920 Purge Timers 892
Accessories and Replacement Parts 653–660 Input/Output (I/O) Device 354 Reset Module 890
Actuators 687–689 Input/Output (I/O) Modules 302, 303, 305 Wiring Subbase 885–886
Flanged 640–647 Installation Millivoltage
Threaded 648–652 Relays 156 Thermostats 23
Three-way 644–647, 652 Integrated Valve Train 949–951, 954, 955 Mixing Valves 281–287
Two-way 640–643, 648–651 Pipe Adapters 950 Accessories 283
Glowfly™ 143 Interface Module Cross Reference 469 Commercial 297–298
GoldTop™ 247 Interface Modules 469 Accessories 298
H Damper Actuators 425 Replacement Parts 298
Heat Sequencers 156 Intermittent Pilot Systems 138, 139 DirectConnect 284–285, 286
Heating Controls Pilot Burner 133 Replacement Parts 286
Training DVD 985 Internal Auxiliary Switch Kits 465 Installation 285
HEPA Air Cleaners 67 Internal Transformers for Series 1 Motors 466 Residential 281–287
Replacement Media 68 Internal Transformers for Series 2 Motors 466 Under sink 287
Herculine Actuators 903 International Approval Services xvii ModBus 900
High Limit Controllers 183 IR-TIM 537 ModBus Module 890
Honeywell Authorized Distributors xxiv ISO 9001 xv Modernization and Replacement
Horsepower ratings xviii Registered Facilities xv Flame Safeguard 969–971
Hot Water Expansion Tanks 256–259, 274–279 K Modules
Commercial Keyboard Displays AQUATROL
Heating systems 275, 276, 277, 279 7800 SERIES 888 Replacement Control 210
Large Capacity 274 SOLA 896 Replacement Zoning 210
Potable water 274, 278 Kit Mounted Motors 470–471 Damper Actuator Interface 425
Humidification 79–89 Accessories 471 Data Acquisition 907
Humidifiers Replacement Parts 471 Direct Spark Ignition 136, 137
Bypass 81–83 Economizer Logic 436–440
Replacement Parts 83
L Economizer Logic Interface 425
Fan 84–85 Legacy Building Systems 356–360 Flame Amplifier 975
Replacement Parts 85 Light Commercial Building Systems 346–355 Hot Surface Ignition 137
Filters 86 Limit Controllers 358 Input/Output (I/O) 302, 303, 305
Replacement Pads 86 Line Voltage Excel Smart I/O 305
Replacement Parts 86 Modutrol IV Motors 449 Outdoor Reset 201
TrueSTEAM 79 Thermostats 1–5, 522–525 Universal Hot Surface Ignition 139
Humidistats 89 LineVoltPRO 1–3 Universal Intermittent Pilot 138, 139
Pneumatic 747–749 Linkages Wall 508
Accessories 749 Butterfly Valves WEBs-AX Security 331
Cover Assemblies 749 Gas 930 Modutrol IV Motors 930
Replacement Parts 749 Dampers 472–477 Auxiliary Potentiometer 466
Humidity and Temperature Transmitters 486 Accessories 473, 477 Auxiliary Switches 467
Humidity Controllers 88, 378 Economizer Motors 472 Interface Modules 469
Humidity Sensors 484–487 Modutrol Motors 473 Internal Auxiliary Switch Kits 465
Duct Mounted 485 Valves 472–477, 690, 691 Internal Transformers for Series 1 Motors 466
Pneumatic 778 Accessories 474, 477 Internal Transformers for Series 2 Motors 466
Hydronic Controllers Butterfly Valves 472 Manual Potentiometer 467, 468
Commercial 355, 927 Globe Valves 475 Order Number Guide 448
Hydronic Controls Modutrol IV Motors 474 Series 2 and Series 3 Motors 445–469
Training Booklets 987 Modutrol Motors 472 Series 2 Motors

x customer.honeywell.com 70-6910
Subject Index
Accessories 464–469 Commercial 924–926 Air Pressure 792
Line Voltage 449 Accessories 926 Diverting 796
Low Voltage 449 Flame Rectifier 924, 926 Manual 797
Non-Spring Return 455, 456, 457, 458 Miniature 925 Minimum Position 797
Slaving Applications 453, 454 Replacement Parts 926 Pneumatic/Electric 793–795
Spring Return 449, 455, 457, 458 Residential 131–135 Replacement Parts 797
with Feedback 455 Accessories 134 SP970 Operation 798
Series 3 Motors Igniter-Burner 133 Pneumatic Valve Actuators 812–816
Non-Spring Return 454, 462 Replacement Parts 134–135 Accessories 816
Spring Return 461, 463 Pilot Gas Valves 952 Cartridge Globe Valves 814
Valve Linkages 474 Pilot Modules 136–140 Replacement Parts 816
Modutrol Motors Pilotstat 131, 132 Pneumatic Valves 817–833
Butterfly Valve Linkages 472 Pneumatic Abbreviations 842–844 Accessories 831–832
Damper Linkages 473 Pneumatic Controls 747–844 Air 821
Monitoring electrical usage 509–515 Accessories 835–841 Mixing 826
Motorized Zone Valves 225–239 Calibration Kit 841 Radiator 824
Builder Packs 234 Damper Actuators 799–811 Replacement Parts 832–833
Built-in balancing 238–239 Torque Ratings 799 Sequencing 822
Diverting 228, 233 Definitions and Abbreviations 842–844 Terminal Unit 830
Line Voltage 225–228 Differential Pressure Controllers 773, 777 Three-way 821, 826
Low Voltage 229–234 Gauges 834–835 POPUP Replacement Filters 69
Normally Closed 229–230 Humidistats 747–749 Portable Combustion Analyzer 902
Normally Open 230–231 Accessories 749 Portable Comfort Control 33
QuickFit 232 Cover Assemblies 749 Potentiometer 786
Replacement Parts 235–237, 239 Replacement Parts 749 PowerPro 146–150
Steam 227, 230 Humidity Sensors 778 1 pole 147
Motors Pressure Controllers 772–777 2 pole 148
Action xvi Accessories 777 3 pole 149
Damper 470 Replacement Parts 777 4 pole 150
Firing Rate 930 Static Pressure Regulator 774 Pressure and Limit Controllers 960–968
Foot Mounted 445–469 Pressure Reducing Valves 772–773 Accessories 968
Auxiliary Potentiometer 466 Switches 792–798 Limit Controller 963
Auxiliary Switches 467 Temperature Controllers 768–771 Line Voltage 967
Feedback 455 Accessories 771 Oil Limit Controller 962
Interface Modules 469 Replacement Parts 771 Pressuretrol® 960–963
Internal Auxiliary Switch Kits 465 Temperature Sensors 779–781 Proportional 965–966
Internal Transformers for Series 1 Accessories 781 Vaporstat® 964
Motors 466 Duct Mounted 780 Pressure Controllers 378
Internal Transformers for Series 2 Insertion element 779 Differential 361
Motors 466 Replacement Parts 781 Pneumatic 772–777
Line Volt 449 Thermometer Calibration Tool 840 Accessories 777
Low Volt 449 Thermostats 750–764 Differential 773, 777
Manual Potentiometer 467, 468 Accessories 761–762 Pressure Reducing Valves 772–773
Non-Spring Return 454, 455, 456, 457, Covers 764 Replacement Parts 777
458, 462 Diffuser 760 Static Pressure 774–775
Slaving Applications 453, 454 Insertion 750 Pressure gauges 255
Spring Return 449, 455, 457, 458, 461, Night setback 756 Pressure Regulating Valves 288–291
463 One or Two Pipes 753, 759 "DialSet" 289–290
Kit Mounted 470–471 One Pipe 760 Accessories 291
Accessories 471 Remote Bulb 751 Compact Design 288
Replacement Parts 471 Replacement Parts 763 Repair Parts 291
MultiPRO 11 Single setpoint 754 Pressure Regulators
N Two Pipes 754, 758 Differential Pressure 243
NEMA Standard xix Training Booklets 987 Residential Gas Controls 102
NEMA standard Transformers 170, 171, 172 Transducer 765 Pressure Sensors 488–489
Network Communications Interface 907 Valve Actuators 812–816 Pressure Switches 956–959
ModBus 907 Valves 817–833 Residential 144
Network Interface 348 Velocity Sensor/Controller 766–767 Pressure-regulated Control Valves 542–565
Non-Programmable Thermostats 2, 3–5, 16–24, 36, Accessories 767 Flanged 564–565
212, 234, 356–357 Replacement Parts 767 Threaded 542–563
Pneumatic Cross Reference 767 Pressuretrol® 182, 773, 960–963
O Pneumatic Damper Actuators 799–811 Limit Controller 963
Oil Burner Control 177, 178, 200 Accessories 810–811 Oil Limit Controller 962
Oil Heating Controls Large dampers 807 Proportional 965–966
Classroom Training 990 Medium dampers 803, 807 Prestige Comfort System 6, 26
Oil Primaries 175–178 Proportional Control 801–809 Primary Relay Modules 845–885
Cross Reference 175 Replacement Parts 810–811 PRO 1000 19
Interrupted Electronic 176 Small dampers 801, 803 PRO 2000 14
Replacement Parts 178 Torque Ratings 799 PRO 3000 18
Oil Systems Diagnostics 179 Unit Ventilator 800 PRO 4000 14
Operator Interface Pneumatic Fittings 836–840 Product Date Code xviii
Local 898 Pneumatic Relays 782–791 Product Selection Matrix for Flame Safeguard
System 897 Accessories 791 Systems 846–863
Order Number Guide xvi Averaging 790 Program Module
Contactors 146 Capacity 787 SOLA Controllers 898
Modutrol IV Motor 448 Electric/Pneumatic 782 Programmable Thermostats 1, 3, 6–14, 213
Outdoor Reset Module 201 Hesitation 791 Commercial 528–539
Outdoor Sensors 211 Load Analyzer 786 Accessories 537
Oxygen Sensor Potentiometer 786 Communicating 539
High Temperature 906 Ratio 788 Programmer Relay Modules 845–885
P Replacement Parts 791 Properties of saturated steam xxiii
Parts and Accessories Reversing 789 Proportional Thermostats 526–527
V5011 and V5013 654 Sector 783 Protectorelay® 177, 178, 200
Perfect Window Ventilation Systems 95 Snap-Acting 784 Protectorelay™ 973–974
Replacement Parts 96 Switching 785 Purge Timers 892
Pilot Burners Pneumatic Switches 792–798 Electromechanical Burner Controls 974

70-6910 xi
Subject Index
Purple Peeper Flame Detectors 913–915 Fan Coil Thermostats 518 Relays 163
Q Fan Humidifiers 85 Residential Gas Valves 115
QuickFit® Zone Valves 232 Flame Detectors 923 SmartValve™ 124
Flame Rods 912 Thermopiles and Thermocouples 130
R Float Valves 296 Transformers 174
R8845U Replacement Cross Reference 218 Fluid Actuators 945 Selection Matrix
RA889A Replacement Cross Reference 220 Gas or Air Butterfly Valves 937 Flame Safeguard Systems 845–863
RA890 Modernization 969 Globe Valves 653, 660 Sensors 478–508
Radiant Manifold Zone Valves 240, 241 Humidifiers 86 Carbon Dioxide (CO2) 478–479
Accessories 242 Ignition Transformers 929 Current 480–482
Replacement Parts 242 Kit Mounted Motors 471 Dew Point 483
RapidZone Software 348 Line Voltage Thermostats 524 Economizers 443–444
Receiver Gauges for Pneumatic Controls 834–835 Manifold Zone Valves 242 Flame Rectification 143
Rectangular Dampers MZV Zone Valves 239 Humidity 484–487
Commercial 384–386 Oil Primaries 178 Duct Mounted 485
Options 386 Perfect Window Ventilation Systems 96 Pneumatic 778
Residential 49–52 Pilot Burners Occupancy 520–521
RedLINK Products 26–34 Commercial 926 Outdoor 211
RedLINK™ enabled 6, 12, 16, 26–33 Residential 134–135 Oxygen
Refrigeration Controllers 362–364 Pneumatic Damper Actuators 810–811 Burner Controls 906
Relay Modules 845–885 Pneumatic Humidistats 749 Pneumatic 778–781
Relays 156–165 Pneumatic Pressure Controllers 777 Pneumatic Velocity Sensor/Controller 766–
Accessories 162 Pneumatic Relays 791 767
Aquastat 193, 196 Pneumatic Switches 797 Accessories 767
Electric Furnace Sequencer 160 Pneumatic Temperature Controllers 771 Replacement Parts 767
Electric Heat 159, 160 Pneumatic Temperature Sensors 781 Pressure 488–489
Fan 158 Pneumatic Thermostats 763 Slab/Floor 211
Fan Manager 161 Pneumatic Valve Actuators 816 Supply/Return/Mixed Loop 211
General Purpose 157 Pneumatic Valves 832–833 Temperature 485, 486, 490–508
Heat Sequencers 156 Pneumatic Velocity Sensor/Controller 767 Accessories 491, 494, 499
Heavy Duty 157 Proportional Thermostats 526 Air 496, 497
Hydronic Switching 214–220 Relays 162 Air Temperature 495
Installation 156 Residential Thermostats 38–40 Averaging 495
Plate-Mounted Receptacle 156 Return Grille Electronic Air Cleaners 66 Discharge Air 45, 495
Pneumatic 782–791 SOLA Controllers 898 Duct Mounted 495, 496, 497
Accessories 791 Solenoid Gas Valves 955 Pneumatic 780
Averaging 790 SuperVent 251 Electronic 490–494
Capacity 787 Temperature Sensors 491, 505 Immersion 496
Electric/Pneumatic 782 Thermostatic Radiator Valve Operators 272 Indoor 15
Hesitation 791 TrueDRY 77–78 Insertion element 779
Load Analyzer 786 V5055/V5097 Industrial Gas Valves 951 Outdoor 15, 28, 33
Potentiometer 786 Variable Frequency Drives 746 Pneumatic 779–781
Ratio 788 Ventilation Systems 98 Accessories 781
Replacement Parts 791 Water Filters 295 Remote 499–500
Reversing 789 Well Assemblies 202 Replacement Parts 491, 505
Sector 783 Wireless Occupancy Solution 521 Residential 15, 28, 33, 34, 45
Snap-Acting 784 Zone Valves 235–237 Return Air 34, 498
Switching 785 Replacement parts Space 498, 499–500
Replacement Parts 162 Aquastat Controllers 201 T775 Controllers 502–503
Selection Guide 163 Replacement Parts Remote Bulb Temperature Wall Module 504–505, 507, 508
Remote Bulb Aquastat Controller 188 Controllers 383 Wall Mounted 496, 498, 501
Remote Bulb Temperature Controller 977 Replacement Power Supply Wireless 33, 507
Repair Parts Air Cleaners 76 Receivers 507
Pressure Regulating Valves 291 Reset Temperature Controls 976–978 Wireless Kits 506
Replacement Cartridges Dual Bulb 977 Service Check Valves 256
Cartridge Cage Valves 677 Outdoor 976, 977 Slave Motors 453, 454
Thermostatic Radiator Mixing or Diverting Proportional 978 SmartValves 117–125
Valves 260 Residential Expansion Tank Kits 258–259 Selection Guide 124
Replacement Filters Residential Expansion Tanks 256–259 SmartVFD COMPACT 693–694
Humidifiers 86 Sizing 257 Accessories 694
Media Air Cleaners 69–70 Residential Gas Controls SmartVFD HVAC 695–700
Perfect Fit 73 Selection Guide 115, 124 SmartVFD HVAC BYPASS 696–700
POPUP 69 Ignition Pilot Modules 140 Software
Return Grille Electronic Air Cleaners 71 Thermopiles and Thermocouples 130 CARE 300
Replacement Lamps Residential Heating Valves and Actuators 222–224 ControLinks System Configuration 902
Ultraviolet Air Treatment System 92 Retrofit Delphi Herculink Software 904
Replacement Modules Current Switches 480 LonSpec Configuration 347
AQUATROL Current Transmitters 482 LonStation 347
Control 210 Dampers 48 RapidZone 348
Zoning 210 Gas Burner Ignition Systems 139 SymmetrE 300
Replacement Pads Round Dampers T7350 Thermostats 540
Humidifiers 86 Commercial 387–388 WEBs R2 340
Replacement Parts Residential 47, 48 WEBs-AX Platform 324
Air Cleaners 74–75 Retrofit 48 WEBs-AX Security Enterprise 328–329
Air Vents 246 Round Thermostat 20, 21 WEBs-AX System 313
AQUATROL Zoning System 211 S SOLA Controllers 894–895
Bypass Humidifiers 83 Accessories 898
Cartridge Globe Valves 667 Sail Switches 99, 364
Selection Chart Demonstrators 981
Combination Gas Controls 126–127 Hydronic 894
Commercial Mixing Valves 298 Industrial Gas Valves and Fluid Actuators 939
Selection Guide Keyboard Display 896
Delphi Combustion System 904 Local Operator Interface 898
Diaphragm Gas Valves 936 Contactors 153
Economizer Systems 435 Program Module 898
DirectConnect Mixing Valves 286 Replacement Parts 898
Economizer Logic Modules 440 Electric Heat Contactors 155
Electric Heat Sequencer 164 Steam 895
Electronic Air Cleaners 62 System Operator Interface 897
Energy Recovery Ventilation Systems 94 Fan Center 167
Ignition Pilot Modules 140 SOLA Displays 896–898

xii customer.honeywell.com 70-6910


Subject Index
Solenoid Gas Valves 953–955 Averaging 495 Covers 764
Accessories 955 Discharge Air 45, 495 Diffuser 760
Normally Open 955 Duct Mounted 495, 496, 497 Insertion 750
Replacement Parts 955 Pneumatic 780 Night setback 756
Safety Shut-off 954 Electronic 490–494 One or Two Pipes 753, 759
Spark Igniter 143 Immersion 496 One Pipe 760
Spyder Controllers 342–343, 508 Indoor 15 Remote Bulb 751
Accessories 343 Insertion element 779 Replacement Parts 763
Temperature Sensors 505 Outdoor 15, 28, 33 Single setpoint 754
Start-Stop Switch 983 Pneumatic 779–781 Two Pipes 754, 758
Steam valve selection xxi Accessories 781 Programmable 1, 3, 6–14, 213
Subbase 356 Replacement Parts 781 Commercial 528–539
Line Volt Thermostats 525 Remote 499–500 Accessories 537
Switching 356 Replacement Parts 491, 505 Communicating 539
Wiring Residential 15, 28, 33, 34, 45 Sensors 498, 499, 500, 504
7800 SERIES 885 Return Air 34, 498 Proportional 526–527
ControLinks 900 Space 498, 499–500 Accessories 526
Electromechanical Burner Controls 975 Spyder Controllers 505 Replacement Parts 526
Expanded Annunciator 885 T775 Controllers 502–503 Replacement Parts 38–40
Submeters 509–515 Wall Module 504–505, 507, 508 Round 20, 21
Integration Nodes 515 Wall Mounted 496, 498, 501 Wireless 29, 31
Networked Power Meters 513 Wireless 33, 507 Wireless System Kits 12, 16, 27–30
Transducers 514 Receivers 507 TIM 537
SuperVent® 249, 250, 251, 258 Wireless Kits 506 Timers 541
Commercial 273 Testers Torque Ratings 799
Replacement Parts 251 Cad Cell 179, 180 TotalZONE 41
Switches Flame Quality 179 Transducers 514
Contactor, Auxiliary 152 Testers and Demonstrators 979–982 Electronic-Pneumatic 765
Current 480–482 7800 SERIES 979 Transformers 53, 168–174
Gas/Air Pressure 956–959 ControLinks 980 Circuit Breaker 169, 170
Pneumatic 792–798 Electromechanical Burner Controls 981 Commercial Ignition 928–929
Air Pressure 792 Flame Simulator 980 Accessories 929
Diverting 796 Meter 982 Replacement Parts 929
Manual 797 Primary Controls Tester 981 General Purpose 168–169
Minimum Position 797 SOLA Demonstrators 981 Hydronic Heating Controls 221
Pneumatic/Electric 793–795 Thermocouples NEMA standard 170, 171, 172
Replacement Parts 797 Universal 128 Selection Guide 174
SP970 Operation 798 Thermocouples and Thermopiles 128–130 Universal 170
Switching Relays 157 Accessories 129 Transmitters
Hydronic 214–220 Selection Guide 130 Current 482
Cross Reference 218, 220 Thermometers 255 Humidity and Temperature 486
Heavy duty 215 Thermopiles Tridicators 255
Universal 217 Replacement Generators 128 TrueDRY 77–78
Sylk™ 508 Thermostat Guards 39–40 Accessories 77–78
SymmetrE Building Management System 300 Thermostatic Radiator Valves Replacement Parts 77–78
System Display, ControLinks 900 Accessories 267–268 TrueIAQ 80
T Cartridge balancing 267 TrueSTEAM 79
Tandem Linkages 476 Cartridge replacement tool 268 Accessories 79
Tanks Cross Reference 265 TrueZONE 32, 41–43
Commercial Expansion 274–279 High Capacity 261–262 U
Heating systems 275, 276, 277, 279 Mixing or Diverting 260 Ultraviolet Air Treatment System 75, 90–92
Large Capacity 274 Replacement Cartridges 260 Replacement Lamps 92
Potable hot water systems 274, 278 Pneumatic 824 Ultraviolet Flame Detectors 913–921
Sizing 274 Standard Capacity 263–265 Adjustable Sensitivity 919
Domestic Expansion 256–259 Steam 266 Minipeepers 916–917
Sizing 257 Thermostatic Radiator Valves Actuators Self-Check 918, 921
Telephone Access Module 37 High Capacity 271–272 Solid State 920
Temperature Controllers 365–383 Standard Capacity 269–270 Under sink Mixing Valves 287
Accessories 382, 383 Thermostatic Radiator Valves and Actuators 260– Underwriters Laboratories Inc xvii
Agricultural 365–366, 369–370, 373 272 of Canada xvii
Cross Reference 377 Thermostats 356, 516–519 Unit Vent Controllers 354
Accessories 38–40
Discharge Air 358
Commercial 516–540
V
Discharge Water 359 Valve Actuators 680–692
Line Voltage 367, 368 Resources 540
Communicating 35–36 Accessories 692
Pneumatic 768–771 Cartridge Globe Valve 680–681
Accessories 771 Residential 212
Cross Reference 528–529, 530 Fan Coil 685–686
Replacement Parts 771 Accessories 686
Proportional 769–770 Dual Setpoint 357
Economy 3, 22–24 Pneumatic 812–816
Refrigeration 362–364 Accessories 816
Remote Bulb 371–372, 374, 379–380, 768 Electric Heat 1–5
Fan Coil Cartridge Globe Valves 814
Accessories 382 Replacement Parts 816
Remote mounting 363, 375, 376, 379–380 Accessories 518
Digital 519 VC Series 682–684
Remote sensing 378 Fail Safe 675–676
Remote Sensors 375, 769–770 Replacement Parts 518
Hydronic 212, 213 Fail Safe Proportional 684
Replacement Parts 383 Proportional 683
Reset 976–978 Line Voltage 1–5, 516–519, 522–525
Accessories 524 Two-position 682
Dual Bulb 977 Valve and Actuator Assemblies 542–565, 567–600,
Outdoor 976, 977 Heavy Duty 523
Medium Duty 522 602–639, 675–676
Proportional 978 Valve Proving System 868, 873, 875, 878, 883, 888
Return Air 367 Replacement Parts 524
Mercury Free 21–23 Valves
Temperature gauges 255 Accessories for V5011, V5013 654
Temperature Indicator 359 Millivoltage 23
Non-Programmable 2, 3–5, 16–24, 36, 212, Ball 566–600
Temperature Sensors 485, 486, 490–508 Boiler Fill 254
Accessories 491, 494, 499 234, 356–357
Air 495, 496, 497 Pneumatic 750–764
Accessories 761–762

70-6910 xiii
Subject Index
Butterfly 601–639 Pressure Regulating 288–291 Replacement Parts 295
Accessories 639 "DialSet" 289–290 Reversing 292
Gas or Air 937 Accessories 291 Rinseable 294
Replacement Parts 937 Compact Design 288 Water Heaters 190
Three-way 618–639 Repair Parts 291 WEBs R2 System 338–341
Two-way 602–617 Pressure-regulated Control Valves 542–565 Controllers 338–339
Cage 662 Flanged 564–565 WEBs-AX
Cartridge Cage 668–677 Threaded 542–563 Controllers 319–322
Accessories 677 Rebuild Kits 655–660 Displays 323
Replacement Cartridges 677 Residential Gas WEBs-AX Security 326–337
Three-way 672–673 Selection Guide 115 Compact Security Solution 332
Two-way 668–671 Residential Heating 222–224 Controllers 330
Cartridge Globe 663–667 Service Check 256 Enclosures and Power Supplies 337
Accessories 667 Solenoid Gas 953–955 Modules 331
Actuators 814 Accessories 955 Readers and Keypads 334–335
Replacement Parts 667 Normally Open 955 Request to Exit Devices 336
Three-way 665–667 Replacement Parts 955 WEBs-AX Suite
Two-way 663–664 Safety Shut-off 954 Controllers 317–318
Commercial Gas Thermostatic Radiator 260–272 Accessories 318
Diaphragm 931–936 Accessories 267–268 WEBs-AX System 312–325
Accessories 936 Cartridge balancing 267 Architecture 312
High Temperature 932 Cartridge replacement tool 268 Software Platform 313
On/Off 933 Cross Reference 265 WebStat® Controller 345, 539
Pressure Regulating 934–936 High Capacity 261–262 WebVision Controller 345
Replacement Parts 936 Mixing or Diverting 260 Well Assemblies 202
Control Ball Replacement Cartridges 260 Whole House Air Cleaners 67
Flanged 567–574 Standard Capacity 263–265 Replacement Media 68
Threaded 575–600 Steam 266 Wireless
Three-way 571–574, 593–600 Under sink Mixing 287 Portable Comfort Control 33
Two-way 567–570, 575–592 VC Series Sensors 33
Fan Coil 678–679 Actuators 682–684 Temperature Sensors 507
Three-way 679 Fail Safe Proportional 684 Kits 506
Two-way 678 Proportional 683 Receivers 507
Float 296 Two-position 682 Zoning 30, 32
Replacement Parts 296 Fail Safe Actuator Assemblies 675–676 Wireless Occupancy Solution 520–521
FlowCheck 252 Low voltage 224 Accessories 521
Gas Water and Steam 542–679 Replacement Parts 521
Residential 101–116 Zone 225–242 Wireless System Kits 12, 16, 27–30
Accessories 126–127 Builder Packs 234 Wireless Thermostats 29, 31
Continuous Pilot 103–106 Built-in balancing 238–239 Wiring Subbase
Direct Ignition 110–112 Diverting 228, 233 ControLinks 900
Intermittent Pilot 106–109 Line Voltage 225–228 Electromechanical Burner Controls 975
Line Voltage 101 Low Voltage 229–234 Microprocessor Burner Controls 885–886
Low Voltage 101 Normally Closed 229–230 Z
Millivoltage 114 Normally Open 230–231 Zio LCD Wall Module 508
Pressure Regulators 102 QuickFit 232 Zone Control Builder Packs 234
Replacement Parts 126–127 Replacement Parts 235–237, 239 Zone Valves 225–242
Universal Electronic Ignition 113 Steam 227, 230 Builder Packs 234
SmartValves 117–125 Vaporstat® 964 Built-in balancing 238–239
Globe 640–660, 661 Variable Frequency Drives 693–746 Diverting 228, 233
Accessories 653 Accessories 746 Line Voltage 225–228
Actuators 687–689 Replacement Parts 746 Low Voltage 229–234
Flanged 640–647 with Bypass 696–700, 708–745 Manifold 240–242
Replacement Parts 653, 660 VAV Controllers 352 Accessories 242
Threaded 648–652 VAV Units 801, 803, 806, 809 Pre Assembled 240
Three-way 644–647, 652 Ventilation Systems Replacement Parts 242
Two-way 640–643, 648–651 Accessories 98 Normally Closed 229–230
Industrial Gas 946–951 Energy Recovery 93 Normally Open 230–231
Accessories 951 Replacement Parts 94 QuickFit 232
Integrated Valve Train 949–951 Fresh Air 97 Replacement Parts 235–237, 239
Pipe Adapters 950 Perfect Window 95 Steam 227, 230
Replacement Parts 951 Replacement Parts 96 ZonePRO® 527
Linkages Replacement Parts 98 Cross Reference 527
Gas 930 Videotape Zoning
Magnetic 181 Zoning 985 Training Videotape 985
Accessories 181 VisionPRO 8–9 Wireless 32
Mixing 281–287 VisionPRO IAQ 7, 35 Wireless Adapter Kits 30
Accessories 283 Voltmeter and Microammeter 982 Zoning Dampers 47–53
DirectConnect 284–285, 286 W Accessories 53
Replacement Parts 286 Water and Steam Valves 542–679 Actuators 470
Installation 285 Ball 566–600 Zoning Demonstrator 995
Mixing or Diverting 297–298 Butterfly 601–639 Zoning Panels
Accessories 298 Cage 662 Accessories 46
Replacement Parts 298 Cartridge Cage 668–677 and Kits 41–46
Pilot Gas 952 Cartridge Globe 663–667 Zoning Systems
Pneumatic 817–833 Fan Coil 678–679 AQUATROL 203–213
Accessories 831–832 Globe 640–660, 661 Accessories 211
Air 821 Pneumatic 817–831 Boiler Reset Control Panels 205, 207
Mixing 826 Pressure-regulated Control Valves 542–565 Expansion Panels 208, 209
Pressure Reducing 772–773 Water Controls 281–298 Relay Control Panels 203, 204
Radiator 824 Commercial 297–298 Replacement Control Modules 210
Replacement Parts 832–833 Water Filters 292–295 Replacement Parts 211
Sequencing 822 Accessories 295 Replacement Zoning Modules 210
Terminal Unit 830 Backwash Controls 295
Three-way 821, 826 High flow capacity 293

xiv customer.honeywell.com 70-6910


ISO 9001
Honeywell Environmental and Combustion Controls Maintains
ISO 9001:2008 Registration
What is ISO? The following facilities are registered under ISO 9001:2008 registered
ISO is the International Organization for Standardization. ISO standards by Quality Management Institute; Certificate # CERT-0038166:
used to apply only to manufacturing, but now can be applied to many
types of businesses. This promotes a common standard for accessing ACS ECC – Golden Valley Facility
systems worldwide. 1985 Douglas Drive North
Golden Valley, MN 55422-3992
What does ISO 9001 registration involve? USA
ISO 9001 is part of the ISO 9000 family. Registration is evidence that a File No: 014498
Quality Management System has been put in place to verify that
customer requirements are being identified and met. This means that an Honeywell Limited - Honeywell Limitée Control Products
Organization has demonstrated the capability to define, document, and 35 Dynamic Drive
control the processes that define the product or service being supplied. Scarborough, Ontario M1V 4Z9
Continuous improvement is assured through the preventive and Canada
corrective actions that result from a comprehensive system of Internal File No: 001082
Audits and Agency (3rd party) Audits.
Honeywell International ACS ECC (West Coast Operations)
Registration focuses on the concept of companies using a process 2055 Dublin Drive
approach to quality management. ISO requires that companies meet San Diego, CA 92154-8203
some very specific requirements, which include defining the process USA
used and controls for each level of every process, from design, through File No: 014499
delivery of the finished product or service. Systems, procedures and
documentation are required for all processes. Honeywell International Manufacturas de Chihuahua S de RL de CV
Avenida Cristobal Colon #11364 Complejo Ind. Chihuahua
Each facility must be registered separately since it is the quality Chihuahua, C.P. 31136
management system of each facility that is registered, not the products México
that are manufactured by the system. File No: 014501
Characteristics of ISO Compliant Businesses Honeywell International ACS ECC (Mexhon)
ISO Management system standards provide the organization with a Mexhon S.A. de C.V. Blvd. Insurgentes No. 8503-2
model to follow in setting up and operating the management system. Tijuana, Baja, CA
This model incorporates the features on which experts in the field have México
reached a consensus as representing the international state of the art. A File No: 014504
management system, which follows the model - or “conforms to the
standard” - is built on a firm foundation of state-of-the-art practices. It is Honeywell International Inc., A Delaware Corporation ACS ECC
a well-organized operation with trained and motivated people. It 304 S. Chicago Avenue
continually rethinks how it runs its business and focuses on meeting and Freeport, IL 61032
exceeding customer specifications through eliminating non-value-added USA
functions. File No: 014587
It welcomes outside auditors who review its processes and ensure Honeywell International Inc., A Delaware Corporation
continual improvement against a universally recognized standard of 25 E. Spring Street
performance. Freeport, IL 61032
USA
What does Honeywell ISO registration offer you? File No: 014588
It offers the confidence and peace of mind that the Honeywell quality
system requires production processes that meet highest standards for Honeywell International Manufacturas de Chihuahua S de RL de CV
consistency and control, which translates to consistent product quality. Ave. Parque Industrial Juárez #3328
Parque Industrial Juárez
Honeywell ISO Registered Facilities Juárez, Chihuahua 32630
Many of the products described in this catalog are built in ISO registered México
facilities. File No: 1065696

70-6910 xv
General Information
Order Specification Number System
TYPE LETTER TYPE NUMBER SUFFIX LETTER OS NUMBER
V 4055 A 1007
The type letter is the single letter, or two letter group, which begins the L, LA or LS — Limit controllers.
model number. This letter usually indicates the general type of device M — Motors.
involved, however, some product model numbers may not follow these P — Pressure controllers.
designations exactly. If you have questions about a particular product PM — Program modules.
designation, please contact your Honeywell sales representative. A list Q — Accessories.
of type letters used is shown below (some may fit in more than one QS — Communication interface modules.
category): R, RA or RW — Relays.
A — Testers. RM — Primary controls.
AT — Transformers. S — Switches and ignition modules.
BC — Microcomputer burner control system. ST — Electronic fan timers.
C or CS — Combustion controls; sensors. SV — Integrated controls.
D or DM — Dampers. T, TA or TS — Thermostats and remote bulb temperature
DSP — Demonstrators. controllers.
EL — Lighting controls. TG — Thermostat guards.
ER — Energy recovery ventilators. V, VR, VS or VW— Valves.
F — Electronic air cleaners. W — Load control panels, accessories.
H — Humidity controls, including combination Y — Package sets.
temperature and humidity controllers. ZM — Software packages.

Summary of Honeywell Control Series Designations


Series
Designation Controller Type Controller Action Relay or Valve Type Motor Action Example
Series 20 3-wire, low voltage Makes circuit to start; — Low voltage; rotates 180 to open, V2045
(2-position) makes second circuit to continues 180 to close; stops on power
stop. interruption.
Series 40 2 wire, line voltage Makes circuit to start; Line voltage coil circuit; makes (opens) Line voltage; motor drives open when T42, L4064,
(2-position) breaks it to stop. when powered; breaks (closes) when powered; spring returns on power L4008
power interrupted. interruption.
Series 50 Mechanical (nonelectrical) series. V5011
Series 60 3-wire, line voltage Makes circuit to start; — Old style—line voltage equivalent to M6284
(2-position) makes second circuit to series 20. New style—line or low
stop. voltage drives open when powered
open; reverses and drives closed when
powered closed; stops on power
interruption.
Series 70 Electronic series. M7285,
C7031
Series 80 2-wire, low voltage Makes circuit to start; Low voltage coil circuit; makes (opens) Low voltage; motor drives open when T87, L8124
(2-position) breaks it to stop. when powered; breaks (closes) when powered; spring return closed on power
power interrupted. interruption.
Series 90 3-wire, low voltage Varies resistance — Low voltage; motor modulates position T921,
(modulating) between common in response to changes in controlled M9164,
terminal and two end variable signaled by controller. W899
terminals in response to
controlled variable.

xvi customer.honeywell.com 70-6910


General Information
Approval Bodies
Most of the devices described in this catalog have been approved or their designs upon compliance with the appropriate national standards.
listed by one or more of the approval bodies listed below. Upon such compliance, the manufacturer is granted an Appliance
Underwriters Laboratories Inc. Certificate or an Accessory Certificate and is permitted to display the
Underwriters Laboratories Inc., is a not-for-profit organization that trademarked Laboratories' Certification Seal or trademarked
examines and tests devices, systems and materials. Its membership Laboratories' Certification Symbol on the appliance or accessory.
represents a broad cross section of industry, education, and International Approval Services—Canada
government. IAS, now part of CSA and no longer known as IAS, represents all
Field inspectors for Underwriters Laboratories Inc., do not normally segments of the Canadian gas industry, has been accredited by the
inspect equipment installed on job sites, but restrict their activities Standards Council of Canada and the Standards Advisory Committee to
entirely to periodic inspections of products coming off manufacturers' prepare National Standards in the area of equipment for use with natural
assembly lines. gas and propane. CSA has laboratories in Toronto, Canada.
The three general categories of acceptance of a product by Each standard is intended to be used within the scope of the standard
Underwriters Laboratories Inc., are: by the manufacturing sector, those applying the equipment or those
1. Listing responsible for its application. It is the responsibility of the user to
2. Component Recognition determine in each case that the standard is suitable for the application.
3. Classification IAS operates a certification program for gas appliances, equipment,
Listed devices are structurally and functionally complete and suitable and accessories.
for field installation. Canadian Gas Association (CGA), is now part of CSA and is no longer
Component Recognized devices are incomplete in some way that known as CGA, although some legacy products still may display the
makes them unsuitable for general field installation. They are intended CGA mark.
to be factory installed as part of some other piece of equipment. American Gas Association (AGA) is also now part of CSA and is no
Classified devices or products have been evaluated as to specific haz- longer known as AGA, although some legacy products still may display
ards only. the AGA mark.
Underwriters Laboratories of Canada can also provide certification Factory Mutual
services to Canadian standards, which is displayed as a “c” adjacent to Factory Mutual is an association of mutual insurance companies
the UL mark (cUL). dedicated to loss prevention. Through its research arm, the Factory
Canadian Standards Association Mutual Research Corporation, it investigates means of preventing and
The Canadian Standards Association is a not-for-profit, membership- minimizing fire and other losses. Factory Mutual Laboratories test and
based, non-governmental organization which provides a national approve two broad categories of devices and materials:
standardizing body for Canada. 1. Those used for the control or prevention of property damage.
2. Those that in themselves would present serious hazards if not
The Canadian Standards Association Testing Laboratories,
properly designed.
inaugurated in May 1940, is a division of the Canadian Standards
Factory Mutual Acceptance refers to a specific installation or
Association, and is recognized as a testing and investigating agency by
arrangement of equipment. Installations using approved devices, if
Inspection Authorities and by Fire Marshals and Fire Commissioners
found satisfactory following review of plans and inspection of completed
throughout Canada.
work, are “accepted”.
The Canadian Standards Association Laboratories test and examine
A continuing follow-up program is carried out through periodic plant
electrical products submitted for approval in compliance with pertinent
inspections and reports of performance in actual use.
Canadian Standards Association codes and standards.
The Canadian Standards Association now includes International CE Mark (“Conformité Européene” European Self-Certification
Approval Services (IAS). mark)
CSA can also provide certification services to UL standards, which is CE marking is mandatory for products covered by one or more
indicated by a “US” adjacent to the CSA mark. Directives. The manufacturer must apply the CE mark and declare
International Approval Services—U.S. conformity to the applicable Directives in order to bring a product on the
IAS, now part of CSA and no longer known as IAS, is the testing market in the European Community. CE marking requirements vary
organization of the American gas industry with laboratories in from Directive to Directive, and even within Directives.
Cleveland, Ohio and Irvine, Calif. The CSA sponsors the American Some of the Directives (e.g. Gas Appliance Directive) require third
National Standards Institute Z21 and Z83 Committees on standards for party testing by Notified Bodies, in which case a product surveillance
gas-fired equipment. contract with a Notified Body is also mandatory. Other Directives can be
Any manufacturer of gas appliances or gas appliance accessories satisfied by Declarations of Conformity provided by the manufacturer as
may submit their products to the Laboratories and secure certification of a result of internal testing and documentation.

70-6910 xvii
Reference Information
Date Code Taxes
A date code is stamped on each device to identify the date of The amount of any and all present or future taxes or other government
manufacture. charges upon the production, shipment, installation or sale of the
In October 1975, Honeywell adopted the industry standard date code equipment covered hereby, including use or occupation taxes, shall be
system of a 4-digit code. The first 2 digits indicate the year; the second 2 added to the price and paid by the Purchaser; or in lieu thereof, the
digits indicate the week of the year. EXAMPLE: 7812—the last week of Purchaser shall furnish the Company with a tax-exemption certificate
March 1978. acceptable to the taxing authorities.
For devices manufactured before October 1975, the following date
code was used. If the letter “R” is added as a third letter, it indicates a
repair date.
A January G July H 1962 Z 1970
International Controls
B February H August G 1963 Y 1971 Some Honeywell controls are available with Celsius scales and/or at
C March I September F 1964 X 1972 110/220V, 50 Hz. For information on the availability of these devices,
D April J October E 1965 W 1973 contact:
E May K November D 1966 V 1974 Commercial/Industrial Combustion Controls
F June L December C 1967 U 1975 Honeywell International Inc., MN10-181B
B 1968 T 1976 1985 Douglas Drive North
A 1969 Golden Valley, MN 55422-3992

All other controls and systems:


Terms of Payment and Prices International Marketing MN10-131A
Honeywell International Inc.
Contact your local Honeywell TRADELINE Wholesaler or Authorized 1985 Douglas Drive North
Distributor for your discount and terms of payment. Golden Valley, MN 55422-3992

Horsepower Ratings
Ratings of Honeywell controls listed herein are in amperes, and All motors do not necessarily come within the maximum ampere
correspond generally to the values for various horsepowers as shown in ratings shown in the table, and control devices must be used which
this chart. Full load ratings are taken from the National Electrical Code, have a rating equal to, or greater than, the actual motor running and
1978 edition; locked motor ratings are 6 times full load rating (ac) or 10 starting currents.
times full load rating (dc).

120V 240V
Approximate Horsepower Full Load Locked Rotor Full Load Locked Rotor
1/6 ac 4.4 26.4 2.2 13.2
dc — — — —
1/4 ac 5.8 34.8 2.9 17.4
dc 3.1 31.0 1.6 16.0
1/3 ac 7.2 43.2 3.6 21.6
dc 4.1 41.0 2.0 20.0
1/2 ac 9.8 58.8 4.9 29.4
dc 5.4 54.0 2.7 27.0
3/4 ac 13.8 82.8 6.9 41.4
dc 7.6 76.0 3.8 38.0
1 ac 16.0 96.0 8.0 48.0
dc 9.5 95.0 4.7 47.0
1-1/2 ac 20.0 120.0 10.0 60.0
dc 13.2 132.0 6.6 66.0
2 ac 24.0 144.0 12.0 72.0
dc 17.0 170.0 8.5 85.0
3 ac 34.0 204.0 17.0 102.0
dc 25.0 250.0 12.2 122.0

xviii customer.honeywell.com 70-6910


Reference Information
NEMA Standard Classification Code for Flame Safeguard
Enclosures
NEMA 1—General purpose. for indoor protection, where conditions are NEMA 6—Submersible. For submerged operation under specified
not unusually severe. pressures and time.
NEMA 2—Driptight. Designed to exclude falling moisture or dirt. Partic- NEMA 7—Hazardous Locations, National Electrical Code Class 1
ularly applicable to cooling rooms, laundries, etc., where condensation (circuit breaks in air).
is prevalent. For indoor use. NEMA 8—Hazardous Locations, National Electrical Code Class 1
NEMA 3—Weather Resistant (weatherproof). For outdoor use; (circuit breaks immersed in oil).
designed to withstand all normal exposure to natural elements. Controls NEMA 9—Hazardous Locations, National Electrical Code Class 2.
mounted on pullout racks for easy access. With rain hood and weather
NEMA 10—Explosion-proof. Meets U.S. Bureau of Mines requirements
seals.
for explosive atmospheres.
NEMA 4—Watertight. Withstands water pressure from 1 in. hose
NEMA 11—Acid or Fume Resistant. Provides for immersion of enclosed
nozzle, 65 gallons per minute, from distance of not less than 10 ft for
equipment in oil.
five minutes. Suitable for maritime applications, breweries, etc.
NEMA 12—IIndustrial Use. Excludes oils, dust, moisture, to satisfy
NEMA 5—Dust-tight. Equipped with dust-tight gaskets. Suitable for mills individual requirements.
and other high-dust atmospheres.

Conversion of Pressure Units


(Convert by multiplying value in known pressure units by factor listed under required pressure unit.)
Required Pressure Unit
Kilo- Pounds per Ounces per Millimeters Kilograms Inches of Inches of Feet of Centimeters of
Known Pressure Unit pascals sq in. sq in. of Mercury per sq cm Water Mercury Water Water
Centimeters of Water 0.0981 0.0142 0.227 0.735 0.000999 0.394 0.0289 0.0328 —
Feet of Water 2.99 0.433 6.94 22.4 0.0305 12.0 0.883 — 30.5
Inches of Mercury 3.39 0.491 7.86 25.4 0.0345 13.6 — 1.13 34.6
Inches of Water 0.249 0.0361 0.578 1.87 0.00254 — 0.0735 0.0833 2.54
Kilograms per sq cm 98.1 14.2 228.0 735.0 — 394.0 29.0 32.8 1000.0
Millimetres of Mercury 0.133 0.0193 0.308 — 0.00136 0.535 0.0394 0.0446 1.36
Ounces per sq in. 0.431 0.0625 — 8.24 0.00439 1.73 0.128 0.144 4.40
Pounds per sq in. 6.89 — 16.0 51.7 0.0703 27.7 2.04 2.31 70.4
Kilopascals — 0.145 2.32 7.52 0.010 4.02 0.295 0.334 10.2
Absolute Pressure = Gauge Pressure +14.74 psi.

Capacities
Most gas capacities listed in this catalog are stated for natural gas,
based on 1,000 Btu per cu ft, 0.64 sp. gr. nat. gas, at a pressure drop of Total Heating Value for Gas X
1.0 in. w.c. (37.3 MJ/m3, 0.64 sp. gr. at a pressure drop of 0.25 kPa). Conversion
To calculate the Btu/h capacity for other gases, multiply the listed Btu/cu ft MJ/m3 At sp. gr. Factor (multiply)
Btu/h capacity by the conversion factor. 500 to 800 18.7 to 29.8 0.60 0.516a
800 to 950 29.8 to 35.4 0.70 0.765a
2500 93.3 1.53 (LP gas) 1.62
a Nominal conversion factor for range of total heat value.
For gases not listed in table, use one of the following formulas:

ListedÑBtu/h Capacity 0.64 Btu/cu ft (MJ/m3 gas X) Btu/h Capacity


=
(0.64 sp. gr.) sp. gr. gas X 1000 Btu/cu ft (37.3 MJ/m3 gas X

or

Btu/h Capacity sp. gr. gas A Btu/cu ft (MJ/m3) gas B Btu/h Capacity
=
(gas A) sp. gr. gas B Btu/cu ft (MJ/m3) gas A gas B
M18317

70-6910 xix
Reference Information
Power & Heat Btu Contents of Fuels
1 Btu 776 ft-lb Grade or Type Unit Btu
0.293 Watt-hr
No. 1 Oil Gallon 137,400
252 cal
No. 2 Oil Gallon 139,600
1 cal 0.003968 Btu
0.0011619 Watt-hr No. 3 Oil Gallon 141,800
1 Btu/h 0.293 Watt No. 4 Oil Gallon 145,100
4.2 cal/min No. 5 Oil Gallon 148,800
1 Watt 3.413 Btu/h No. 6 Oil Gallon 152,400
1 Watt-hr 3.413 Btu Nat. Gas cu ft 950 to 1,150
1 kW (1000 Watts) 3413 Btu/h Propane cu ft 2,550
1 kW-hr 3413 Btu Butane cu ft 3,200
1 hp 0.746 kW
2544.65 Btu/h
33,000 ft-lb./min
1 Bohpa 9.809 kW
33,479 Btu/h
34.5 lb of steam per hour
a
Boiler Output Horsepower is the equivalent of the heat required to
evaporate 34.5 lb of water per hour into dry, saturated steam at 212 F.

Commercial/Industrial Combustion Conversion Factors


Simplified method of determining combustion air required to com- Normally useful for determining standard cubic feet of fuel consumed
pletely burn a given amount of fuel. when metering pressure is other than standard; e.g., gas passing
Btu/hr input through a volumetric gas meter at 5 psig. (The heating value of fuel
Cf/h Air = gases is based on Btu/cf at standard gas conditions.)
100
M18318

To correct gas volume from one set of conditions to another.


P1 V1 P2 V2
------------ = ------------
T1 T2
P = Absolute pressure.
= 14.7 + gauge psi.
T = Absolute temperature in -R = 460.
V = Volume in any consistent terms.
Turndown ratio of fixed area burner.
Maximum Pressure Drop across Burner Maximum Firing Rate
T.D. = =
Minimum Pressure Drop across Burner Minimum Firing Rate
M18319
Where pressure drops are expressed in the same units.
Relationship between flow capacity at a specified pressure drop and Cv factor.
Cv = Flow Factor. Defined as the amount of water at 60 F in gallons Q=1360 Cv
per minute which will flow through a valve in the open position with a (P1 - P2) P2
pressure drop through the valve of 1 pound per square inch.
For capacity conversion to gases the following may be used for
GT
pressure ratios less than critical ratios. M18320
Q = Standard cubic feet per hour at 14.7 psia and 60 F.
P1 = Inlet pressure, psia.
P2 = Outlet pressure, psia.
T = Absolute temperature in -R = -F+460.
G = Specific gravity of the gas.

xx customer.honeywell.com 70-6910
Reference Information
Steam Valve Selection
There are five steps in choosing the appropriate steam valve:
1. Determine the steam medium temperature, pressure, and the
Modulating
pressure drop across the valve. (This is often determined using Two-way modulating steam valves are typically used to throttle the flow
inlet vs. outlet pressures. For example, a valve with a 75 psi inlet of steam in proportion to the load. Similar to water valves, when sizing a
and a 50 psi outlet would have a pressure drop of 25 psi.) modulating valve for steam, consider the pressure throughout the valve
2. Using this information (and Tables 1and 2), calculate the Cv or travel. The pressure drop must be large enough so that, as the valve
select the pipe size. starts to close, it can diminish the flow. If this is not accomplished, the
3. Check the average pressure and the temperature to determine
valve is not able to maintain control throughout its entire range of travel.
the quality of the steam medium. The quality of the steam is:
• Saturated However, a pressure drop that is too large causes noisy valve operation
• Superheated and decreases the life-span of the valve.
4. Establish the required valve body configuration for the applica-
tion. This is typically fixed by the particular application and is
often part of the design specifications. Standard body configura- Calculating Cv
tions are:
• Two-way To determine the appropriate Cv rating, one must know:
—Straight-through Supply pressure (psi)
—Angle Body Valve differential pressure (Δp)
5. See valve and actuator Product Overview Table and individual Flow rate (lb/hr)
catalog pages.
NOTE: Traditionally, steam valves use a linear flow characteristic, but Q v
equal percentage characteristics are used in Europe.
C v = ---------------------
63.5 Δp
All steam valves are two-way valves. There are two valve operation
control types; two-position (open/closed) and modulating (proportional). Q = Quantity of Steam (pounds per hour)
v = specific volume of steam (cubic feet per pound) at the average
pressure in the valve
Two-Position 63.5 = scaling constant
Two-position steam valves are typically selected based on the pipe size Δp = pressure drop in psi
of the line, which is matched to the coil to deliver the amount of steam
required at design conditions. For example, if the pipe size is three When Btu/hr (heat output) is known:
inches in diameter, you would select a three inch steam valve. Delivered Using the supply pressure, differential pressure and the Table 1, deter-
heat is a function of steam pressure, valve capacity index (Cv), and the mine the value of Factor A for the application. Then using Factor A, the
percentage open time of the valve (duty cycle). The condensed steam flow rate and Table 2, determine the Cv for the application.
may be returned to the boiler by active or passive methods.
Table 1. Calculations of Factor A for Steam Valves

Return Pressure (psig)


Supply Supply
(psig) 0 1 2 3 4 5 6 7 8 9 10 11 12 15 20 25 30 40 50 60 70 (Bar)
2 4.0 5.5 0.1
3 3.2 3.9 5.4 0.2
4 2.7 3.1 3.7 5.2 0.3
5 2.4 2.7 3.0 3.7 5.1 0.3
6 2.2 2.3 2.6 2.9 3.6 5.0 0.4
7 2.0 2.1 2.3 2.5 2.9 3.5 4.9 0.5
8 1.8 1.9 2.1 2.2 2.5 2.8 3.4 4.8 0.6
9 1.7 1.8 1.9 2.0 2.2 2.4 2.8 3.3 4.7 0.6
10 1.6 1.7 1.7 1.8 2.0 2.1 2.4 2.7 3.3 4.6 0.7
11 1.5 1.6 1.6 1.7 1.8 1.9 2.1 2.3 2.6 3.2 4.5 0.8
12 1.4 1.5 1.5 1.6 1.7 1.8 1.9 2.0 2.3 2.6 3.1 4.4 0.8
15 1.2 1.3 1.3 1.3 1.4 1.4 1.5 1.6 1.7 1.8 1.9 2.1 2.5 1.0
20 1.0 1.0 1.0 1.1 1.1 1.1 1.1 1.2 1.2 1.3 1.3 1.4 1.4 1.8 1.4
25 0.9 0.9 0.9 0.9 0.9 0.9 0.9 1.0 1.0 1.0 1.0 1.1 1.1 1.2 1.7 1.7
30 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.9 0.9 0.9 1.0 1.1 1.6 2.1
40 0.7 0.7 0.7 0.6 0.6 0.6 0.6 0.6 0.6 0.7 0.7 0.7 0.7 0.7 0.8 0.9 1.0 2.8
50 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.5 0.5 0.5 0.5 0.5 0.6 0.6 0.6 0.6 0.7 0.9 3.4
60 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.6 0.9 4.1
70 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.5 0.5 0.6 0.8 4.8
80 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.5 0.6 0.8 5.5
.00 .07 .14 .21 .28 .34 .41 .48 .55 .62 .69 .76 .83 1.03 1.38 1.72 2.07 2.76 3.45 4.14 4.83
Return Pressure (Bar)

70-6910 xxi
Reference Information
Table 2. Steam valve Cv final Calculation

Steam Flow Rate (in lb/hr)


5 10 25 50 75 100 200 300 400 500 600 700 800 900 1k 2k 3k 4k 5k 7.5k 10k 20k 30k
0.4 0.16 0.31 0.47 0.63 1.26 1.9 2.5 3.1 3.8 4.4 5.0 5.7 6.3 13 19 25 31 47 63 126 189
0.5 0.08 0.20 0.39 0.59 0.79 1.6 2.4 3.1 3.9 4.7 5.5 6.3 7.1 7.9 16 24 31 39 59 79 157 236
0.6 0.09 0.24 0.47 0.71 0.94 1.9 2.8 3.8 4.7 5.7 6.6 7.6 8.5 9.4 19 28 38 47 71 94 189 283
0.7 0.11 0.28 0.55 0.83 1.1 2.2 3.3 4.4 5.5 6.6 7.7 8.8 9.9 11.0 22 33 44 55 83 110 220 331
0.8 0.13 0.31 0.63 0.94 1.3 2.5 3.8 5.0 6.3 7.6 8.8 10.1 11.3 13 25 38 50 63 94 126 252 378
0.9 0.14 0.35 0.71 1.1 1.4 2.8 4.3 5.7 7.1 8.5 9.9 11.3 13 14 28 43 57 71 106 142 283 425
1 0.16 0.39 0.79 1.2 1.6 3.1 4.7 6.3 7.9 9.4 11.0 13 14 16 31 47 63 79 118 157 315 472
1.1 0.17 0.43 0.87 1.3 1.7 3.5 5.2 6.9 8.7 10.4 12 14 16 17 35 52 69 87 130 173 346 520
1.2 0.19 0.47 0.94 1.4 1.9 3.8 5.7 7.6 9.4 11.3 13 15 17 19 38 57 76 94 142 189 378 567
1.3 0.10 0.20 0.51 1.0 1.5 2.0 4.1 6.1 8.2 10.2 12 14 16 18 20 41 61 82 102 154 205 409 614
1.4 0.11 0.22 0.55 1.1 1.7 2.2 4.4 6.6 8.8 11.0 13 15 18 20 22 44 66 88 110 165 220 441
1.5 0.12 0.24 0.59 1.2 1.8 2.4 4.7 7.1 9 12 14 17 19 21 24 47 71 94 118 177 236 472
1.6 0.13 0.25 0.63 1.3 1.9 2.5 5.0 7.6 10.1 13 15 18 20 23 25 50 76 101 126 189 252 504
1.7 0.13 0.27 0.67 1.3 2.0 2.7 5.4 8.0 10.7 13 16 19 21 24 27 54 80 107 134 201 268 535
1.8 0.14 0.28 0.71 1.4 2.1 2.8 5.7 8.5 11.3 14 17 20 23 26 28 57 85 113 142 213 283 567
1.9 0.15 0.30 0.75 1.5 2.2 3.0 6.0 9.0 12 15 18 21 24 27 30 60 90 120 150 224 299 598
2 0.16 0.31 0.79 1.6 2.4 3.1 6.3 9.4 13 16 19 22 25 28 31 63 94 126 157 236 315 630
2.1 0.17 0.33 0.83 1.7 2.5 3.3 6.6 9.9 13 17 20 23 26 30 33 66 99 132 165 248 331
2.2 0.17 0.35 0.87 1.7 2.6 3.5 6.9 10.4 14 17 21 24 28 31 35 69 104 139 173 260 346
2.3 0.18 0.36 0.91 1.8 2.7 3.6 7.2 10.9 14 18 22 25 29 33 36 72 109 145 181 272 362
2.4 0.19 0.38 0.94 1.9 2.8 3.8 7.6 11.3 15 19 23 26 30 34 38 76 113 151 189 283 378
2.5 0.20 0.39 0.98 2.0 3.0 3.9 7.9 12 16 20 24 28 31 35 39 79 118 157 197 295 394
FACTOR A

2.6 0.20 0.41 1.0 2.0 3.1 4.1 8.2 12 16 20 25 29 33 37 41 82 123 164 205 307 409
2.7 0.21 0.43 1.1 2.1 3.2 4.3 8.5 13 17 21 26 30 34 38 43 85 128 170 213 319 425
2.8 0.22 0.44 1.1 2.2 3.3 4.4 8.8 13 18 22 26 31 35 40 44 88 132 176 220 331 441
2.9 0.23 0.46 1.1 2.3 3.4 4.6 9.1 14 18 23 27 32 37 41 46 91 137 183 228 343 457
3 0.24 0.47 1.2 2.4 3.5 4.7 9.4 14 19 24 28 33 38 43 47 94 142 189 236 354 472
3.1 0.24 0.49 1.2 2.4 3.7 4.9 9.8 15 20 24 29 34 39 44 49 98 146 195 244 366 488
3.2 0.25 0.50 1.3 2.5 3.8 5.0 10.1 15 20 25 30 35 40 45 50 101 151 202 252 378 504
3.3 0.26 0.52 1.3 2.6 3.9 5.2 10.4 16 21 26 31 36 42 47 52 104 156 208 260 390 520
3.4 0.27 0.54 1.3 2.7 4.0 5.4 10.7 16 21 27 32 37 43 48 54 107 161 214 268 402 535
3.5 0.28 0.55 1.4 2.8 4.1 5.5 11.0 17 22 28 33 39 44 50 55 110 165 220 276 413 551
3.6 0.28 0.57 1.4 2.8 4.3 5.7 11.3 17 23 28 34 40 45 51 57 113 170 227 283 425 567
3.7 0.29 0.58 1.5 2.9 4.4 5.8 11.7 17 23 29 35 41 47 52 58 117 175 233 291 437 583
3.9 0.31 0.61 1.5 3.1 4.6 6.1 12 18 25 31 37 43 49 55 61 123 184 246 307 461 614
4.4 0.35 0.69 1.7 3.5 5.2 6.9 14 21 28 35 42 49 55 62 69 139 208 277 346 520
4.5 0.35 0.71 1.8 3.5 5.3 7.1 14 21 28 35 43 50 57 64 71 142 213 283 354 531
4.6 0.36 0.72 1.8 3.6 5.4 7.2 14 22 29 36 43 51 58 65 72 145 217 290 362 543
4.7 0.37 0.74 1.9 3.7 5.6 7.4 15 22 30 37 44 52 59 67 74 148 222 296 370 555
4.8 0.38 0.76 1.9 3.8 5.7 7.6 15 23 30 38 45 53 60 68 76 151 227 302 378 567
4.9 0.39 0.77 1.9 3.9 5.8 7.7 15 23 31 39 46 54 62 69 77 154 231 309 386 579
5 0.39 0.79 2.0 3.9 5.9 7.9 16 24 31 39 47 55 63 71 79 157 236 315 394 591
5.2 0.41 0.82 2.0 4.1 6.1 8.2 16 25 33 41 49 57 66 74 82 164 246 328 409 614
5.3 0.42 0.83 2.1 4.2 6.3 8.3 17 25 33 42 50 58 67 75 83 167 250 334 417
5.4 0.43 0.85 2.1 4.3 6.4 8.5 17 26 34 43 51 60 68 77 85 170 255 340 425
5.5 0.43 0.87 2.2 4.3 6.5 8.7 17 26 35 43 52 61 69 78 87 173 260 346 433

xxii customer.honeywell.com 70-6910


Reference Information
IMPORTANT
If the steam is superheated, it can require a valve with a
larger Cv. Use the following equation to determine the correct
Cv to use:
CAUTION
Pressure reducing valves can also produce
CV = CV Calculated x [1 + (0.00075 x S)] superheated steam and exceed the valve’s
Where: S = degrees of superheat (in Fahrenheit). temperature rating.
For example: 100 psi steam at 338F passing through a pres-
If the calculated Cv falls between two valve sizes, use a valve with the sure reducing valve gives up no heat as it expands to 10 psi, so
next higher Cv value unless the calculated Cv is within 10 percent of the the 10 psi steam downstream will be at 338F not 239F. This is
next lower Cv value. 99 Fahrenheit degrees of superheat and downstream valves
and piping will be exposed to the higher temperature. To correct
for superheated steam, 1 Btu/lb is added for each Fahrenheit
degree of superheat.

Superheat–The additional heat contained in a vapor at a tem-


perature higher than the saturation (boiling) temperature corre-
sponding to the pressure of the vapor.

Table 3. Properties of Saturated Steam

Boiling Point or
Vacuum, Steam Specific V Maximum Allowable
Inches of Temperature Volume (V), (For valve Pressure Drop, psi. Heat of the Latent Heat of Total Heat of
Mercury Deg. F cu. ft/lb sizing) (For valve sizing) Liquid, Btu Evap., Btu Steam, Btu
29 76.6 706.00 26.57 0.23 44.7 1048.6 1093.3
25 133.2 145.00 12.04 1.2 101.1 1017.0 1118.1
20 161.2 75.20 8.672 2.4 129.1 1001.0 1130.1
15 178.9 51.30 7.162 3.7 146.8 990.6 1137.4
14 181.8 48.30 6.950 3.9 149.7 988.8 1138.5
12 187.2 43.27 6.576 4.4 155.1 985.6 1140.7
10 192.2 39.16 6.257 4.9 160.1 982.6 1142.7
8 196.7 35.81 5.984 5.4 164.7 980.0 1144.7
6 201.0 32.99 5.744 5.9 168.9 977.2 1146.1
4 204.8 30.62 5.533 6.4 172.8 974.8 1147.6
2 208.5 28.58 5.345 6.9 176.5 972.5 1149.0
Gage
Pressure, psig
0 212.0 26.79 5.175 7.4 180.0 970.4 1150.4
1 215.3 25.20 5.020 7.8 183.3 968.2 1151.5
2 218.5 23.78 4.876 8.4 186.6 966.2 1152.8
3 221.5 22.57 4.751 8.8 189.6 964.3 1153.9
4 224.4 21.40 4.626 9.4 192.5 962.4 1154.9
5 227.1 20.41 4.518 9.8 195.3 960.6 1155.9
6 229.8 19.45 4.410 10.4 198.0 958.8 1156.8
7 232.3 18.64 4.317 10.8 200.5 957.2 1157.7
8 234.8 17.85 4.225 11.4 203.0 955.5 1158.5
9 237.1 17.16 4.142 11.8 205.4 954.0 1159.4
10 239.4 16.49 4.061 12.4 207.7 952.5 1160.2
11 241.6 15.90 3.987 12.8 209.9 951.1 1161.0
12 243.7 15.35 3.918 13.4 212.1 949.7 1161.8
15 249.8 13.87 3.724 14.8 214.2 948.3 1162.5
20 258.8 12.00 3.464 17.4 227.4 939.5 1166.9
25 266.8 10.57 3.251 19.8 235.6 934.0 1169.6
30 274.0 9.463 3.076 22.4 243.0 928.9 1171.9
40 286.7 7.826 2.797 27.4 255.9 919.9 1175.8
50 297.7 6.682 2.585 32.4 267.1 911.9 1179.0
60 307.3 5.836 2.416 37.4 277.1 904.7 1181.8
70 316.0 5.182 2.276 42.4 286.1 898.0 1184.1
80 323.9 4.662 2.159 47.4 294.3 891.9 1186.2
90 331.2 4.239 2.059 52.4 301.9 886.1 1188.0
100 337.9 3.888 1.972 57.4 308.9 880.7 1189.6
120 350.0 3.337 1.827 67.4 321.7 870.7 1192.4
140 360.9 2.923 1.710 77.4 333.1 861.5 1194.6

70-6910 xxiii
Authorized Distributors
Honeywell Authorized Distributors
Certain Honeywell product lines are available only through authorized distributors. Authorized distributors have chosen to make a commitment to
representing Honeywell controls. They are committed to excellence:
• in education, by providing continuing training in HVAC industry developments to their employees.
• in application, by choosing the right system for each application.
• in marketing, by providing customers with accurate information and efficient service.

7800 SERIES Distributors Combustion Solutions Distributors


For commercial and industrial burner and boiler controls and systems, For commercial and industrial combustion solutions and components.
and 7800 SERIES burner controls.
Commercial Controls Distributors
Authorized Systems Distributors Access to light commercial building automation systems, standalone
Complete access to building automation systems, standalone controls controls and commercial field device products.
and commercial field device products.
ControLinks™ Representatives
For ControLinks Products.

FOR YOUR CONVENIENCE


For more information about authorized distributors or for the
name of a particular outlet in your area, use our toll-free number.

1-800-345-6770

xxiv customer.honeywell.com 70-6910


Electric Heat Thermostats

Home Controls
LineVoltPRO® 8000 7-Day Programmable Hydronic Thermostat
The TL8100 Hydronic Thermostat offers the energy savings of a
programmable control for a wide variety of applications. With the
TL8100 there’s no need to carry multiple thermostats for different
applications. It can be used to control 2-way zone valves, 3-way
zone valves or circulator pumps in both line volt and low volt
applications. It also offers special protection modes to prevent

Indoor Air Quality


system seizures and to reduce callbacks. Easy to install, the
TL8100 is exactly what you need to provide your customers with
cost-efficient programmable control of hydronic heating systems.

Application: Baseboards; Convectors; Fan-forced Heaters; Radiant Operating Humidity Range (% RH): 0% to 95%, non-condensing

Combustion Controls
Ceilings; Central Heating (Conventional) Operating Temperature Range: 32 F to 122 F (0 C to 50 C)
Dimensions, Approximate: 3.3 in. x 3.1 in. x 0.5 in. Differential Temperature: 0.1 F (0.1 C)

Residential
(83 mm x 79 mm x 13 mm) Accuracy: 0.5 C
Color: White Power Method: 2 X AA (LR6) batteries
Programmability: 7-Day Program Sensor Element: Thermistor
Electrical Connections: 6 in. (150 mm) tinned copper lead wires Switch Type: Relay
Electrical Ratings: Maximum Load: 5 A (resistive), Mounting: Vertical
2 A (inductive) @ 24 VDC, 120 Vac, 240 Vac;
Approvals:
Compatible with millivolt systems Underwriters Laboratories, Inc. Approved
Voltage: Millivolt Compatible; 24 Vdc; 120 Vac; 240 Vac

Hydronic Controls
Setting Temperature
Switch Positions Range
Terminal
Product Number System Fan Stages (F) (C) Designations Comments Used With
TL8100A1008 No Switch 1 Heat 40 F to 85 F 5 C to 30 C R, W, Remote input for telephone controller or Aube CT240-02
(X, C, optional home automation system; Comfort, Telephone
remote input) Economy and Vacation Presets; With Controller
Backlit Display

Controls
LineVoltPRO® 8000 7-Day Programmable Electric Heat Thermostat

Water
The LineVoltPRO® programmable thermostat provides electronic
control of 208/240 Vac resistive rated electric baseboard heaters,
radiant ceiling heat, convectors and fan forced heaters.
• 7 day programmable - maintain the pre-set program schedule for up
to 20% energy savings, or modify the schedule to fit your lifestyle.

Building Automation
• Electronic temperature control - precision of ±1 F saves up to an
additional 10% on heating bills.
• Large, clear, backlit display - easy to read in various lighting
conditions.
• Soundproofed for quiet operation - reduces the clicking noise
commonly heard with conventional thermostats.
• On/Off or On/Standby switch allows you to turn the thermostat off at
the end of the heating season.
• Early start - ensures programmed temperature is reached by
programmed time.
• Heating indicator - at a glance confirmation that the heat is on.

Components
• Maintenance free - no batteries required.

Commercial
Application: Electric baseboards, convectors and fan forced heaters Operating Temperature Range: 32F to 122 F (0 C to 50 C)
(resistive rated loads). Frequency: 50 Hz; 60 Hz
Dimensions, Approximate: 4 7/8 in. high x 2 3/4 in. wide x 7/8 in. deep Voltage: 208/240 Vac
(124 mm high x 70 mm wide x 23 mm deep) Sensor Element: Thermistor
Display Size: 2.67 sq. in. Mounting: Vertical
Color: Premier White®
Approvals:
Programmability: 7 Day Program
Pneumatic Controls

Canadian Standards Association: cCSAus, File Number: LR76030


Electrical Connections: 5.5 in. (140mm) tinned copper lead wires Underwriters Laboratories, Inc. UL Listed 9R12, File Number: E183695

Switch Positions Setting Temperature Range


Product Number Electrical Ratings System Fan Switching Action Stages (F) (C)
TL8130A1005 16.7 Amps Max; 4000 Watts at 240 VAC, No switch SPST 1 Heat 40 F to 86 F 5 C to 30 C
3470 Watts at 208 VAC
TL8230A1003 15 Amps Max; 3600 Watts at 240 VAC, No switch DPST 1 Heat 40 F to 86 F 5 C to 30 C
Industrial Combustion

3120 Watts at 208 VAC


Controls

70-6910 1
Electric Heat Thermostats
LineVoltPRO® 7000 Digital Non-Programmable
Electric Heat Thermostats
The LineVoltPRO® non-programmable digital thermostat provides
electronic control of 208/240 Vac resistive rated electric baseboard
heaters, radiant ceiling heat, convectors and fan forced heaters. If
used as directed, electronic thermostats can save up to 10% on
annual heating costs. Savings may vary based on geographic
region and usage.
• Electronic temperature control - precision of ±1 F saves up to 10%
on heating bills.
• Large, clear, backlit display - easy to read in various lighting
conditions.
• Soundproofed for quiet operation - reduces the clicking noise
commonly heard with conventional thermostats.
• On/Off switch allows you to turn the thermostat off at the end of the
heating season.
• Heating indicator - at a glance confirmation that the heat is on.
• Maintenance free - no batteries required.

Application: Electric baseboards, convectors and fan forced heaters Frequency: 50 Hz; 60 Hz
(resistive rated loads). Sensor Element: Thermistor
Dimensions, Approximate: 4 7/8 in. high x 2 3/4 in. wide x 7/8 in. deep Color: Premier White®
(124 mm high x 70 mm wide x 23 mm deep) Mounting: Vertical Mount
Accuracy: ±1 F (±0.5 C)
Approvals:
Switch Type: Relay Canadian Standards Association: cCSAus, File Number: LR76030
Switching Action: DPST Underwriters Laboratories, Inc. UL Listed 9R12, File Number: E183695

Switch Positions Setting Temperature Range


Product Number Electrical Ratings System Fan Stages (F) (C)
TL7235A1003 15 Amps Max; 3600 Watts at 240 VAC, 3120 Watts at No switch 1 Heat 40 F to 86 F 5 C to 30 C
208 VAC

LineVoltPRO® 7000 Non-Programmable Electric Heat Thermostats


The LineVoltPRO® thermostat provides electronic control of 208/
240 Vac resistive rated electric baseboard heaters, radiant ceiling
heat, radiant floor heat, convectors and fan forced heaters.
• Electronic temperature control - precision of ± 1 F saves up to 10%*
on heating bills.
• Easy temperature setting - with single control dial.
• Soundproofed for quiet operation - reduces the clicking noise
commonly heard with conventional thermostats.
• On/Standby switch allows you to turn the thermostat off at the end of
the heating season.
• Temperature range stops - prevents user from setting the
temperature too high or too low.
• Maintenance free - no batteries required.
• 5-year limited warranty.

Application: Electric baseboards, convectors and fan forced heaters Switching Action: SPST
(resistive rated loads). Frequency: 50 Hz; 60 Hz
Dimensions, Approximate: 4 7/8 in. high x 2 3/4 in. wide x 7/8 in. deep Sensor Element: Thermistor
(124 mm high x 70 mm wide x 23 mm deep) Color: Premier White®
Electrical Ratings: 16.7 Amps Max; 4000 Watts at 240 VAC, 3470 Mounting: Vertical Mount
Watts at 208 VAC Approvals:
Accuracy: ±1 F (±0.5 C) Canadian Standards Association: cCSAus, File Number: LR76030
Switch Type: Relay Underwriters Laboratories, Inc. UL Listed 9R12, File Number: E183695

Switch Setting Temperature


Positions Range Minimum Temperature Setting
Product Number Electrical Ratings System Fan (F) (C) (F) (C) Stages
TL7130A1006 16.7 Amps Max; No switch 59 F to 95 F 15 C to 35 C Thermostat maintains Thermostat maintains 1 Heat
4000 Watts at 240 VAC, 45 F when dial is set 7 C when dial is set
3470 Watts at 208 VAC below 59 F. below 15 C.

2 customer.honeywell.com 70-6910
Electric Heat Thermostats

Home Controls
LineVoltPRO 6000® Programmable Thermostat
The LineVoltPRO® programmable thermostat provides electronic
control of 240 Vac resistive rated electric baseboard heaters,
radiant ceiling heat, convectors and fan forced heaters.
• 5-2 day programmable - maintain the pre-set program schedule for
up to 20% energy savings, or modify the schedule to fit your lifestyle.
• Electronic temperature control - precision of ±0.27 F saves up to an
additional 10% on heating bills.

Indoor Air Quality


• Large, clear, backlit display - easy to read in various lighting
conditions.
• Silent operation.
• Heating indicator - at a glance confirmation that the heat is on.
• Maintenance free - no batteries required.
• 5-year limited warranty.

Combustion Controls
Residential
Application: Electric baseboards, convectors and fan forced heaters Operating Temperature Range: 32 F to 99 F (0 C to 70 C)
(resistive rated loads). Differential Temperature: ± 0.27 F (±0.15 C)
Dimensions, Approximate: 4 13/16 in. high x 4 1/2 in. wide x 1 in. Frequency: 50 Hz; 60 Hz
deep (120 mm high x 115 mm wide x 26 mm deep) Voltage: 240 Vac
Color: Premier White® Sensor Element: Thermistor
Programmability: 5-2 Day Program Mounting: Vertical
Electrical Connections: 6 in. (150 mm) tinned copper lead wires
Approvals

Hydronic Controls
Electrical Ratings: 12.5 Amps Max: 3000 Watts at 240 VAC, 2 Amps Underwriters Laboratories, Inc. UL Listed 9R12, File Number: E183695
Min.

Switch positions Setting Temperature Range


Product Number System Fan Switching Action Stages (F) (C)
TL6120A1016 No switch SPST 1 Heat 40 F to 80 F 5 C to 27 C

T410 Electric Heat Thermostats

Controls
Economy thermostats that provide reliable line voltage control of

Water
resistive rated electric heating equipment. Snap-action switch
makes heating circuit on temperature fall.
• Economical.
• Replace virtually any two-wire (T410A) or four-wire (T410B) line
voltage wall-mounted electric heating thermostat.
• Easy to install; 6 in. (150 mm) color-coded leads.
• Include long-lasting Micro Switch® mechanism.

Building Automation
• Rugged, plastic mounting base and one-piece cover with vents.
• Ideally suited to new construction applications.

Application: Electric baseboards, convectors and fan forced heaters Color: Premier White®
(resistive rated loads). Mounting: Vertical Mount

Components
Commercial
Dimensions, Approximate: 4 1/2 in. high x 2 3/4 in. wide x 2 1/4 in.
Approvals:
deep (115 mm high x 70 mm wide x 57 mm deep) Canadian Standards Association: Listed: File No. LR1322
Electrical Ratings: Noninductive Resistive 22A at 120/208/240 Vac. Underwriters Laboratories, Inc. Listed; File No. E47434, Guide No.
19A at 277 Vac. XAPX
Accuracy: 2 C
Differential Temperature: 3 F (2 C) Accessories:
Frequency: 60 Hz 272804A Range Stop and Locking Screws Assembly
Sensor Element: Bimetal
Pneumatic Controls

Switch Positions Setting Temperature Range


Product Number Color System Fan Switching Action Stages (F) Includes
T410A1013 Premier White® No Switch SPST 1 Heat 40 F to 80 F —
T410B1004 White No Switch DPST 1 Heat 40 F to 80 F Positive OFF
Industrial Combustion
Controls

70-6910 3
Electric Heat Thermostats
T498 Electric Heat Thermostats
Electric Heat Thermostats provide line voltage control of electric
heating systems.
• Easy to install; color-coded leads.
• Include thermometer. Include long-lasting Micro Switch®
mechanism; makes on temperature fall.
• Rugged, plastic mounting base.
• Mount on standard 2 x 4 in. outlet box or 4 x 4 in. junction box.
• Select models include extra knob decal for recalibration, if
necessary.

Application: Electric baseboards, convectors and fan forced heaters Sensor Element: Bimetal
(resistive rated loads). Mounting: Vertical Mount
Dimensions, Approximate: 4 9/16 in. high x 2 7/8 in. wide x 1 15/16 in. Approvals:
deep (116 mm high x 73 mm wide x 33 mm deep) Canadian Standards Association: Listed: File No. LR1322
Electrical Ratings: Noninductive Resistive 22A at 120/208/240 Vac. Underwriters Laboratories, Inc. Listed; File No. E47434, Guide No.
19A at 277 Vac. XAPX
Accuracy: 1 F (2 C)
Ambient Temperature Range: 40 F to 80 F (5 C to 27 C) Accessories:
Differential Temperature: 3 F (2 C) 272804A Range Stop and Locking Screws Assembly
Frequency: 60 Hz 272823 Blind Locking Cover and Range Stop Assembly

Setting Temperature
Switch Positions Range
Switching
Product Number Color System Fan Action Stages (F) (C) Includes
T498A1778 Beige No switch SPDT 1 Heat 40 F to 80 F 5 C to 27 C Range stops, locking cover and
extra knob decal for recalibration
T498A1810 Brush gold finish No switch SPST 1 Heat 40 F to 80 F — —
* T498B1512 Brush gold finish No switch DPST 1 Heat 40 F to 80 F — Positive OFF, Range stops, locking
cover and extra knob decal for
recalibration
T498B1553 Brush gold finish No switch DPST 1 Heat 40 F to 80 F — Positive OFF
* TRADELINE models • SUPER TRADELINE models

4 customer.honeywell.com 70-6910
Electric Heat Thermostats

Home Controls
T4398 High Performance Electric Heat Thermostats
High Performance Electric Heat Thermostats provide precise line
voltage control of resistive-rated electric heating equipment.
• For control of resistive-rated baseboard electric heaters.
• Extremely sensitive to temperature changes.
• Replace virtually all standard wall-mounted line voltage thermostats.
• Color-coded leads allow easy installation.
• Include long-lasting Micro Switch® mechanism.

Indoor Air Quality


• Rugged, plastic mounting base.
• Cover thermometer indicates room temperature.
• Well suited for upgrades and high-end new construction.
• Mounts directly on vertical 2 x 4 in. outlet box, or on 4 x 4 in. outlet
box.

Combustion Controls
Residential
Application: Electric baseboards, convectors and fan forced heaters Sensor Element: Vapor filled dual diaphragm
(resistive rated loads). Color: Premier White®
Dimensions, Approximate: 4 1/2 in. high x 2 7/8 in. wide x 2 5/8 in. Mounting: Vertical Mount
deep (115 mm high x 73 mm wide x 67 mm deep) Approvals:
Electrical Ratings: Noninductive Resistive 22A at 120/208/240 Vac. Canadian Standards Association: Listed: File No. LR1322
19A at 277 Vac. Underwriters Laboratories, Inc. Listed; File No. E47434, Guide No.

Hydronic Controls
Accuracy: 1 C XAPX
Ambient Temperature Range: 50 F to 80 F (10 C to 25 C)
Differential Temperature: 2 F (1 C) Accessories:
Setting Temperature Range: 50 F to 80 F 272804A Range Stop and Locking Screws Assembly
Frequency: 60 Hz

Switch Positions
Product Number System Fan Switching Action Stages Includes
* T4398A1021 No Switch SPST 1 Heat Thermometer, range stops and locking cover screws

Controls
* T4398B1029 No Switch DPST 1 Heat Thermometer, range strops, locking cover screws, Positive Off

Water
* TRADELINE models • SUPER TRADELINE models

Building Automation
Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 5
Programmable Thermostats
Prestige™ Comfort System
• Large, easy-to-read backlit full color display shows current indoor
temperature and humidity, temperature setting, date and time on the
home screen. Also displays outdoor temperature and humidity on
home screen (if wireless outdoor sensor is installed)
• Adjustable backlight level allows thermostat to be on full brightness
at all times or dim to the brightness level of choice when the
thermostat is not being used
• Interview-Based Programming wizard to easily and confidently
schedule thermostat temperatures and times
• USB Port allows downloading of installer settings to quickly and
consistently perform setup of thermostats in similar applications
• USB Port also allows easy setup of dealer logo and contact
information on thermostat screen
High Definition Color Touchscreen Thermostat • Real-Time Clock keeps time during power failure; automatically
updates for daylight saving time
• Precise Temperature Control (± 1×F) for reliable and consistent
temperature.
• Multiple HOLD options allows modification of schedule as needed
• Change Reminders to inform it is time to replace Air Filter, humidifier
pad, ultraviolet bulb or batteries in connected devices
• RedLINK™ Enabled to communicate with compatible wireless
devices
• Kit Includes Portable Comfort Control, Wireless Outdoor Sensor and
Prestige™ HD Thermostat

Standard Definition Touchscreen Thermostat


The Prestige™ HD thermostat provides control of 24Vac of heating
and cooling systems. RedLINK™ enabled to work with compatible
wireless accessories. The Prestige™ HD Thermostat Kits contains
Wireless Outdoor Sensor and High Definition (HD) Color
Touchscreen Thermostat.

Application: Up to 2 Heat/2 Cool Conventional Systems Operating Temperature Range: 32 F to 120 F (0 C to 48.9 C)
Up to 3 Heat/2 Cool Heat Pumps Stages: Up to 3 Heat/2 Cool Heat Pump
Dimensions, Approximate: 3 15/16 in. high, 6 7/8 in. wide, or Up to 2 Heat/2 Cool Conventional
1 1/2 in. deep (100 mm. high, 175 mm. wide, 38 mm. deep) Power Method: Hardwired
Display Size: 8.06 sq. in. Outdoor Sensor: Yes, optional
Color: Arctic White Remote Sensor: No
Programmability: 7-Day Multiple Day Programming or Non- Comments: Tri-Lingual Display (selectable for English, French or
Programmable Spanish)
Changeover: Auto or Manual Used With: RedLINK™ enabled thermostats and accessories
Electrical Connections: Screw terminals
Electrical Ratings: 18 to 30 Vac Accessories:
Frequency: 50 Hz; 60 Hz 50028399-001 Cover plate for Prestige Thermostats 7 7/8 in. (200 mm)
Voltage: 18 to 30 Vac x 5 1/2 in. (140 mm)
Operating Humidity Range (% RH): 0 to 90% RH, non-condensing C7089R1013 Senses outdoor temperature and humidity to display on
Humidity Setting Range: Cooling: 40 to 80% RH. Heating: 10 to 80% RedLINK™ enabled thermostats and accessories.
RH. REM5000R1001 Use the Portable Comfort Control anywhere in the
Dehumidification Setting Range: 40 to 80% RH home to experience a new level of comfort and convenience.
Humidification Setting Range: 10 to 60% RH. RedLINK™ Enabled. Works in both zoned and non-zoned
Setting Temperature Range: applications.
Heat: 40 F to 90 F; Cool 60 F to 99F THP9045A1007 THP9045 WireSaver
(Heat: 4.5 C to 32.0 C; Cool: 15.5 C to 37.0 C)

Switch Positions
Product Number System Fan Terminal Designations Includes
THX9321R1008 HEAT-OFF-COOL- AUTO-ON- C, R, Rc, W-O/B, W2-AUX/E, Y, Y2, G, Standard Definition Touchscreen Thermostat
AUTO-EM.HEAT CIRC L, K, HUM, HUM, DHM, DHM
THX9321R5000 HEAT-OFF-COOL- AUTO-ON- C, R, Rc, W-O/B, W2-AUX/E, Y, Y2, G, High Definition Color Touchscreen Thermostat
AUTO-EM.HEAT CIRC L, K, HUM, HUM, DHM, DHM
YTHX9321R1000 HEAT-OFF-COOL- AUTO-ON- C, R, Rc, W-O/B, W2-AUX/E, Y, Y2, G, Standard Definition Touchscreen Thermostat;
AUTO-EM.HEAT CIRC L, K, HUM, HUM, DHM, DHM REM5000R1001 Portable Comfort Control and
C7089R1013 Wireless Outdoor Sensor
YTHX9321R1011 HEAT-OFF-COOL- AUTO-ON- C, R, Rc, W-O/B, W2-AUX/E, Y, Y2, G, Standard Definition Touchscreen Thermostat;
AUTO-EM.HEAT CIRC L, K, HUM, HUM, DHM, DHM C7089R1013 Wireless Outdoor Sensor
YTHX9321R5003 HEAT-OFF-COOL- AUTO-ON- C, R, Rc, W-O/B, W2-AUX/E, Y, Y2, G, High Definition Color Touchscreen Thermostat;
AUTO-EM.HEAT CIRC L, K, HUM, HUM, DHM, DHM REM5000R1001 Portable Comfort Control and
C7089R1013 Wireless Outdoor Sensor
YTHX9321R5012 HEAT-OFF-COOL- AUTO-ON- C, R, Rc, W-O/B, W2-AUX/E, Y, Y2, G, High Definition Color Touchscreen Thermostat;
AUTO-EM.HEAT CIRC L, K, HUM, HUM, DHM, DHM C7089R1013 Wireless Outdoor Sensor

6 customer.honeywell.com 70-6910
Programmable Thermostats

Home Controls
VisionPRO® IAQ Total Home Comfort System
The VisionPRO IAQ touchscreen universal programmable
thermostat provides electronic control of 24 Vac heating and
cooling systems in addition to humidification, dehumidification
and ventilation all with just 3 wires to the thermostat.
• Advanced dual-fuel control.
• Three wires to the living space allows for easy equipment upgrade
without having to run additional thermostat wire.

Indoor Air Quality


• Thermostat connects with Equipment Interface Module or
EnviraZONE panel to control temperature, humidification,
dehumidification and ventilation from a single point in the home.
• Automatically raises humidity levels throughout all rooms in the
home, moisturizing air to prevent symptoms of dryness and to
protect hardwood flooring and woodwork.
• Removes air pollutants by exchanging the stale air in a house with
fresh, filtered air better than having an open window.

Combustion Controls
Residential
Thermostat Dimensions, Approximate: 4 9/16 in. high x 6 in. wide x Dehumidification Setting Range: 40 to 80% RH.
1 1/4 in. deep (116 mm high x 152 mm wide x 32 mm deep) Humidification Setting Range: 10 to 60% RH.
Color: Premier White® Sensor Element: Thermistor
Programmability: 7 Day Multiple Day Programming or Non- Mounting: Horizontal
Programmable Switch Type: Yes, optional
Changeover: Auto/Manual Selectable Outdoor Sensor: Yes, optional
Remote Sensor: Yes, optional

Hydronic Controls
Thermostat Display Size: 10 sq. in.
Electrical Ratings: THM5421 is rated 20 to 30 Vac
Operating Humidity Range (% RH): 5 to 90% RH, non-condensing
Accessories:
32003796-001 Premier White® cover plate 7 7/8 in. (200 mm) x 5 1/2 in.
Differential Temperature: ± 1 F (±0.5 C)
(140 mm)
Stages: Up to 3 Heat/2 Cool Conventional; Up to 4 Heat/2 Cool Heat
C7089U1006 Remote Outdoor Sensor
Pump
C7189U1005 Remote Indoor Sensor
Power Method: Communicating
Voltage: 20 to 30 Vac

Setting
Temperature

Controls
Switch Positions Range

Water
Product Terminal
Number Application Mounting System Fan Designations (F) (C) Comments Used With Includes
TH9421C1004 Conventional Horizontal HEAT- AUTO- 1, 2, 3 Heat: 40 F Heat: 4.5 C Includes Humidification Control THM5421C1008 Thermostat
and Heat OFF- ON- to 90 F; to 32 C; with or without Frost Protection, Equipment only
Pump COOL- CIRC Cool 60 F Cool: 15 C Dehumidification using Whole Interface Module
systems AUTO- to 99F to 37C House Dehumidifier or Air
EM.HEAT Conditioning with High or Low

Building Automation
speed fan, Advanced Patented
Ventilation Control and
Advanced Dual Fuel Heat
Pump Control.
THM5421C1008 Heat/Cool or Vertical — — 1, 2, 3, C, R, Rc, — — Includes Humidification Control TH9421 Equipment
Heat Pump Rh, R, W1-O/B, with or without Frost Protection, VisionPRO IAQ Interface
with Auxiliary W2-Aux, Dehumidification using Whole Thermostat Module Only
Heat W3-Aux2, Y, Y2, House Dehumidifier or Air
G, L, Out1, Out2, Conditioning with High or Low
In1, In2, Dats1, speed fan, Advanced Patented
Dats2, Hum1, Ventilation Control and

Components
Commercial
Hum2, Dhm1, Advanced Dual Fuel Heat
Dhm2, Vnt1, Pump Control.
Vnt2
YTH9421C1002 Heat/Cool or Horizontal HEAT- AUTO- 1, 2, 3, C, R, Rc, Heat: 40 F Heat: 4.5 C Includes Humidification Control — TH9421C1004
Heat Pump OFF- ON- Rh, R, W1-O/B, to 90 F; to 32 C; with or without Frost Protection, Thermostat
with Auxiliary COOL- CIRC W2-Aux, Cool: 60 F Cool: 15 C Dehumidification using Whole and
Heat AUTO- W3-Aux2, Y, Y2, to 99 F to 37 C House Dehumidifier or Air THM5421C10
EM.HEAT G, L, Out1, Out2, Conditioning with High or Low 08 Equipment
In1, In2, Dats1, speed fan, Advanced Patented Interface
Pneumatic Controls

Dats2, Hum1, Ventilation Control and Module


Hum2, Dhm1, Advanced Dual Fuel Heat
Dhm2, Vnt1, Pump Control.
Vnt2
YTH9421C1010 Heat/Cool or Horizontal HEAT- AUTO- 1, 2, 3, C, R, Rc, Heat: 40 F Heat: 4.5 C Includes Humidification Control — TH9421C1004
Heat Pump OFF- ON- Rh, R, W1-O/B, to 90 F; to 32 C; with or without Frost Protection, Thermostat,
with Auxiliary COOL- CIRC W2-Aux, Cool: 60 F Cool: 15 C Dehumidification using Whole THM5421C10
Heat AUTO- W3-Aux2, Y, Y2, to 99 F to 37 C House Dehumidifier or Air 08 Equipment
EM.HEAT G, L, Out1, Out2, Conditioning with High or Low Interface
Industrial Combustion

In1, In2, Dats1, speed fan, Advanced Patented Module and


Dats2, Hum1, Ventilation Control and C7089U1006
Hum2, Dhm1, Advanced Dual Fuel Heat Outdoor
Controls

Dhm2, Vnt1, Pump Control. Temperature


Vnt2 Sensor

70-6910 7
Programmable Thermostats
Commercial VisionPRO® 8000
The TB8220 Commercial VisionPRO 8000 Touchscreen
Programmable Thermostat is an effortless, seven day
programmable thermostat that provides universal system
compatibility, precise comfort control and is easy to-program. The
TB8220 provides temperature control for gas, oil, electric and heat
pumps for up to 2 heat, 2 cool systems.
• Large, clear display with backlight shows the current and set
temperature and time even in the dark.
• Menu-driven programming make setup effortless.
• Beautiful ergonomic design is smart and sophisticated to match your
customers' lifestyle.
• Touchscreen interaction Real-time clock keeps time during power
failures and automatically updates to daylight savings.
• Saving Changes notification lets you know when the schedule
changes have been saved.
• Change reminders let you know when to replace the batteries.
• Holiday Override options allow you to override the program
schedule, as desired.
• Speedy same--schedule programming--no need to copy multiple
days.
• Armchair programming allows you to remove the thermostat from the
wall for programming.

Dimensions in inches (millimeters)


Color: Premier White®
WALLPLATE Electrical Connections: 24 VAC or Battery
3-3/8 (86) Network Communications: None
Dimensions, Approximate: 6 in. wide x 4 9/16 in. high x 1 3/8 in. deep
(152 mm wide x 116 mm high x 35 mm deep)
Accessories:
32003796-001 Premier White® cover plate 7 7/8 in. (200 mm) x 5 1/2 in.
(140 mm)
TR21 20 K ohm NTC non-linear Temperature Wall Module
3-3/8 (86)
TR21-A 10 K ohm NTC non-linear Temperature Wall Module (for
averaging only)
C7189U1005 Remote Indoor Sensor
C7770A1006 6 in. Duct Probe for Return Air 20 K ohm NTC non-linear
Temperature Sensor
C7772A1004 20 K ohm NTC non-linear Wall Flush Mount Temperature
THERMOSTAT Sensor without logo
THERMOSTAT
AND WALLPLATE C7772A1012 20 K ohm NTC non-linear Wall Flush Mount Temperature
6 (152)
1-3/8 (35)
Sensor with Honeywell logo
C7041B2005 20K ohm NTC Temperature Sensor with 6 in. insertion
C7041B2013 20K ohm NTC Temperature Sensor with 12 in. insertion
C7041C2003 20K ohm NTC Temperature Sensor with 18 in. insertion
C7041P2004 20K ohm NTC Stainless Steel Button Sensor, 11/16 in.
dia.
C7089U1006 Remote Outdoor Sensor
W7212A1009 Series 72 Economizer Logic Module with Demand
4-9/16
(116) Control Ventilation

M22421

Setting Temperature
Switch Position Range
Terminal
Product Number Application System Fan Designations Stages (F) (C) Comments
TB8220U1003 24 Vac heating and HEAT- AUTO- R, Rc, W (O/B), Up to 2 Heat/ Heat: 40 F Heat: 4.5 C The L-terminal is an input
cooling systems; OFF- ON W2 (W1), Y, Y2, 2 Cool to 90 F; to 32 C; only;
Heat Pump Systems; COOL- L, A, G, C, S1, S2 Conventional; Cool: 50 F Cool: 10 C Selectable programmable
Conventional AUTO- Up to 3 Heat/ to 99 F to 37 C or non-programmable;
systems; Packaged EM.HEAT 2 Cool Heat Pump Includes A terminal to
RTU enable an economizer or
control a lighting panel
when used as a time of day
relay

8 customer.honeywell.com 70-6910
Programmable Thermostats

Home Controls
VisionPRO® 8000 Touchscreen 7-Day Programmable Thermostat
• Large, Clear Display with Backlighting current temperature, set
temperature and time are easy-to-read and all are displayed on the
home screen.
• Menu Driven Programming Guides you through the scheduling
process, showing only necessary information and choices on each
screen.
• Ability to Select Multiple Days allows you to easily customize the

Indoor Air Quality


thermostat for your unique schedule.
• Real-Time Clock keeps time during power failure; automatically
updates for daylight saving time.
• Armchair Programming allows you to remove thermostat from wall to
set the schedule.
• Precise Temperature Control (±1 F) reliable, consistent comfort.
• Multiple HOLD options allow you to modify schedule indefinitely or
for a specific time.
• Change Reminders reminds you to service or replace the air filter,

Combustion Controls
humidifier pad, ultraviolet lamp or thermostat batteries.
The VisionPRO Touchscreen Universal Programmable • Adaptive Intelligent Recovery® - ensures programmed temperature

Residential
Thermostats provides electronic control of 24 Vac heating and is reached by programmed time.
cooling systems or 750 mV heating system. • Temperature range stops - prevents user from setting the
temperature too high or too low.
• Keypad lockout options for partial or full lockout.
Dimensions, Approximate: 4 9/16 in. high x 6 in. wide x 1 1/4 in. deep Current (Fan): 0.6A running
(116 mm high x 152 mm wide x 32 mm deep) Power Method: Battery or Hardwired
Display Size: 10 sq. in. Sensor Element: Thermistor

Hydronic Controls
Color: Premier White® Mounting: Horizontal
Programmability: 7 Day Multiple Day Programming or Non- Outdoor Sensor: Yes, optional outdoor or indoor remote
Programmable
Changeover: Auto/Manual Selectable Accessories:
Electrical Ratings: 20 to 30 Vac or 750 mV 32003796-001 Premier White® cover plate 7 7/8 in. (200 mm) x 5 1/2 in.
Frequency: 50 Hz; 60 Hz (140 mm)
Operating Humidity Range (% RH): 5 to 90% RH, non-condensing C7089U1006 Remote Outdoor Sensor
Differential Temperature: ± 1 F (±0.5 C) C7189U1005 Remote Indoor Sensor
Current (Cooling): 1.0 A running C7735A1000 Discharge Air Sensor (used with TH8321U1097 for
Current (Heating): 1.0 A running desert humidification)

Controls
Water
Setting Temperature
Switch Positions Range
Terminal
Product Number Application System Fan Designations Stages (F) (C) Comments
TH8110U1003 Heat/Cool or HEAT- AUTO- R, RC, C, W (O/B), Up to 1 Heat/ Heat: 40 F to Heat: 4.5 C to Selectable: Programmable or
Heat Pump OFF- ON- Y, G, S1, S2 1 Cool 90 F; 32 C; Non-Programmable; Selectable;
without Auxiliary COOL- CIRC Cool: 50 F to Cool: 10 C to Heat Only or Cool Only

Building Automation
Heat AUTO 99 F 37 C
TH8320U1008 Heat/Cool or HEAT- AUTO- R, RC, W (O/B), Up to 2 Heat/ Heat: 40 F to Heat: 4.5 C to Selectable: Programmable or
Heat Pump with OFF- ON- W2 (AUX), Y, Y2, 2 Cool 90 F; 32 C; Non-Programmable. The L
Auxiliary Heat COOL- CIRC L, E, G, C, S1, S2 Conventional; Cool: 50 F to Cool: 10 C to terminal is an input or output.
AUTO- Up to 3 Heat/ 99 F 37 C
EM.HEAT 2 Cool Heat
Pump
TH8321U1006 Heat/Cool or HEAT- AUTO- R, RC, W (O/B), Up to 2 Heat/ Heat: 40 F to Heat: 4.5 C to Includes Dehumidification
Heat Pump with OFF- ON- W2 (AUX), Y, Y2, 2 Cool 90 F; 32 C; Control. Selectable:
Auxiliary Heat COOL- CIRC L, E, G, C, S1, S2 Conventional; Cool: 50 F to Cool: 10 C to Programmable or Non-
AUTO- Up to 3 Heat/ 99 F 37 C Programmable. The L terminal is

Components
Commercial
EM.HEAT 2 Cool Heat an input or output.
Pump
TH8321U1097 Heat/Cool or HEAT- AUTO- R, C, W (O/B), W2 Up to 2 Heat/ Heat: 40 F to Heat: 4.5 C to Includes a set of Universal IAQ
Heat Pump with OFF- ON- (E/AUX), Y, Y2, G, 2 Cool 90 F; 32 C; contacts to control
Auxiliary Heat COOL- CIRC L, U1, U1, S1, S2 Conventional; Cool: 50 F to Cool: 10 C to humidification, dehumidification
AUTO- Up to 3 Heat/ 99 F 37 C or ventilation. Also has
EM.HEAT 2 Cool Heat advanced Dual Fuel control.
Pump Selectable Programmable or
Pneumatic Controls

Non-Programmable. The L
terminal is an input or an output.
Industrial Combustion
Controls

70-6910 9
Programmable Thermostats
CommercialPRO® 7000
The COMMERCIALPRO® 7000 Programmable Thermostat is an
effortless, seven-day programmable thermostat that provides
universal system compatibility, precise comfort control and is
easy-to-program.
The TB7220 provides temperature control for gas, oil, electric and
heat pumps for up to 2 heat, 2 cool systems.
• Large, clear display with backlight shows the current and set
temperature and time--even in the dark.
• Menu-driven programming make setup effortless.
• Beautiful ergonomic design is smart and sophisticated to match your
customers’ lifestyle.
• Real-time clock keeps time during power failures and automatically
updates to daylight savings.
• Saving Changes notification lets you know when the schedule
changes have been saved.
• Change reminders let you know when to replace the batteries.
• Holiday Override options allow you to override the program
schedule, as desired.
• Speedy same--schedule programming--no need to copy multiple
days.
• Armchair programming allows you to remove the thermostat from the
wall for programming.

Dimensions in inches (millimeters)


Color: Premier White®
Electrical Connections: 24 VAC or Battery
Network Communications: None
Dimensions, Approximate: 6 in. wide x 3 3/4 in. high x 1 3/8 in. deep
(152 mm wide x 96 mm high x 35 mm deep)
Accessories:
50002883-001 FocusPRO® 5000/6000 and PRO 3000/4000 Cover
Plate Assembly
TR21 20 K ohm NTC non-linear Temperature Wall Module
TR21-A 10 K ohm NTC non-linear Temperature Wall Module (for
THERMOSTAT
AND WALLPLATE
averaging only)
C7189U1005 Remote Indoor Sensor
6 (152)
1-3/8 C7770A1006 6 in. Duct Probe for Return Air 20 K ohm NTC non-linear
(35) Temperature Sensor
C7772A1004 20 K ohm NTC non-linear Wall Flush Mount Temperature
Sensor without logo
C7772A1012 20 K ohm NTC non-linear Wall Flush Mount Temperature
Sensor with Honeywell logo
C7041B2005 20K ohm NTC Temperature Sensor with 6 in. insertion
3-3/4
(95)
C7041B2013 20K ohm NTC Temperature Sensor with 12 in. insertion
C7041C2003 20K ohm NTC Temperature Sensor with 18 in. insertion
C7041P2004 20K ohm NTC Stainless Steel Button Sensor, 11/16 in.
dia.
C7089U1006 Remote Outdoor Sensor
W7212A1009 Series 72 Economizer Logic Module with Demand
Control Ventilation
M13668

Setting Temperature
Switch Position Range
Terminal
Product Number Application System Fan Designations Stages (F) (C) Comments
TB7220U1012 24 Vac heating and HEAT- AUTO- R, Rc, W (O/B), Up to 2 Heat/ Heat: 40 F Heat: 4.5 C Selectable programmable or non-
cooling systems; OFF- ON W2 (W1), Y, 2 Cool to 90 F; to 32 C; programmable;
Heat Pump Systems; COOL- Y2, A, G, C, Conventional; Cool: 50 F Cool: 10 C Includes A terminal to enable an
Conventional AUTO- S1, S2 Up to 3 Heat/ to 99 F to 37 C economizer or control a lighting
systems; Packaged EM.HEAT 2 Cool Heat panel when used as a time of day
RTU Pump relay

10 customer.honeywell.com 70-6910
Programmable Thermostats

Home Controls
MultiPRO™ 7000
The MultiPRO provides temperature control for gas, oil, electric,
heat pumps, PTACs, and fan-coil equipment for the following
types of applications: 1H/1C conventional; Up to 2H/1C heat pump;
4 pipe fan coil (3 fan speeds); 2 pipe fan coil (3 fan speeds); 2 pipe
fan coil w/Auxiliary Heat (3 fan speeds); PTAC (Hi, Lo fan speeds).
• Large, clear display with backlight shows the current and set
temperature and time--even in the dark.

Indoor Air Quality


• Menu-driven programming make setup effortless.
• Beautiful ergonomic design is smart and sophisticated to match your
customers’ lifestyle.
• Real-time clock keeps time during power failures and automatically
updates to daylight savings.
• Saving Changes notification lets you know when the schedule
changes have been saved.
• Change reminders let you know when to replace the batteries.
• Holiday Override options allow you to override the program

Combustion Controls
The MultiPRO™ Multispeed and Multipurpose Thermostat is an
schedule, as desired.
effortless, seven-day programmable or non-programmable
• Speedy same--schedule programming--no need to copy multiple

Residential
thermostat that provides universal system compatibility, precise
days.
comfort and is easy to program.
• Armchair programming allows you to remove the thermostat from the
wall for programming.
• Programmable or non-programmable modes.
• Remote setback input for occupancy sensors or timeclocks.
• VersaSpeed™ fan ramping algorithm and fan reset algorithm (fan
coil and PTAC applications).
• Up to 3 fan speeds for fan coil and 2 fan speeds for PTAC

Hydronic Controls
applications.
• Remote Indoor air sensing option (20K ohm or 10K ohm)
Color: Premier White® C7770A1006 6 in. Duct Probe for Return Air 20 K ohm NTC non-linear
Electrical Connections: 24 VAC or Battery Temperature Sensor
Network Communications: None C7772A1004 20 K ohm NTC non-linear Wall Flush Mount Temperature
Sensor without logo
Accessories: C7772A1012 20 K ohm NTC non-linear Wall Flush Mount Temperature
50002883-001 FocusPRO® 5000/6000 and PRO 3000/4000 Cover Sensor with Honeywell logo
Plate Assembly C7041B2005 20K ohm NTC Temperature Sensor with 6 in. insertion
TR21 20 K ohm NTC non-linear Temperature Wall Module C7041B2013 20K ohm NTC Temperature Sensor with 12 in. insertion
TR21-A 10 K ohm NTC non-linear Temperature Wall Module (for

Controls
C7041C2003 20K ohm NTC Temperature Sensor with 18 in. insertion

Water
averaging only) C7041P2004 20K ohm NTC Stainless Steel Button Sensor, 11/16 in.
C7189U1005 Remote Indoor Sensor dia.
WSK-24 Wireless Occupancy Solution

Setting Temperature
Switch Position Range
Terminal

Building Automation
Product Number Application System Fan Designations Stages (F) (C) Comments
TB7100A1000 Conventional, HEAT- AUTO-ON; R, Rc, W1, O/B, 1 Heat/ 1Cool Heat: 40 F Heat: 4.5 C Includes 3 speed fan
Heat Pump, OFF- Fan Coil: HI- Y, G, G2, G3, C, Conventional; to 90 F; to 32 C; control and configurable
Fan Coil, and COOL- MED-LO-AUTO; S1, S2 Up to 2 Heat/ Cool: 50 F Cool: 10 C sensor input for indoor
PTAC Systems AUTO- PTAC: HI-LO- 1 Cool Heat Pump; to 99 F to 37 C temperature, occupancy
EM.HEAT AUTO 2 or 4 pipe Fan sensor, or changeover;
Coil; Selectable
Up to 2 Heat/ 1 programmable or non-
Cool PTAC programmable

Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 11
Programmable Thermostats
Wireless System Kits
• EQUIPMENT INTERFACE MODULE (EIM): All HVAC equipment is
wired to the module. Module receives communication from the
wireless devices.
• RETURN AIR SENSOR: Works with the Equipment Interface
Module to maintain safe indoor temperatures if power is lost at the
wireless thermostat. Maintains 62 F for heating and 82 F for cooling.
• PORTABLE COMFORT CONTROL: Allows homeowners to sense
and control temperature from any room in the home to provide
comfort where they spend their time. Manage comfort and energy
savings from one convenient control. Touchscreen interface with
backlit display. Displays outdoor temperature and humidity. 1 year
battery life. 2 month low battery warning.
• WIRELESS OUTDOOR SENSOR: Reliable performance in all
climates. Installs in minutes. Up to 5 year battery life. 2 month low
battery warning.
• RedLINK™ WIRELESS TECHNOLOGY: Powered by RedLINK™
reliability. No interference with other wireless devices in the home.
Everything you need to relocate thermostat or upgrade equipment
without running new wires. Includes the Portable Comfort Control
to sense and control temperature from any room and a Wireless
Outdoor sensor to display outdoor temperature and humidity on all
devices.
• WIRELESS FocusPRO® THERMOSTAT: Same great features of the
FocusPRO® thermostat - now wireless. Installs in minutes. Displays
outdoor temperature and humidity. 1 year battery life. 2 month low
battery warning. Dual Fuel enabled.

Application: Gas, oil, electric, heat pump, forced warm air, hot water, Accessories:
steam or gravity 50002883-001 FocusPRO® 5000/6000 and PRO 3000/4000 Cover
Electrical Ratings: Plate Assembly
Equipment Interface Module--18 to 30 Vac, 50 Hz; 60 Hz 50007298-001 12 pack of medium coverplates (5 in. x 6 7/8 in.)
Changeover: Auto/Manual Selectable
Currents (Cooling): 1.0 A running Replacement Parts:
Currents (Heating): 1.0 A running 50007072-001 Replacement Battery Holder for FocusPRO® TH5220,
Currents (Fan): 0.6 A running TH5320, TH6110, TH6220, and TH6320 Thermostat
Power Method: Thermostat--Battery

Switch Positions
Product Number System Fan Terminal Designations Stages Includes
YTH6320R1015 HEAT-OFF- AUTO-ON C, R, Rc, Rh, W-O/B, W2- Up to 3 Heat/ REM5000R1001 Personal Comfort Station;
COOL-AUTO- Aux/E, Y, Y2, G, L, RAS 2 Cool Heat Pump; TH6320R1004 Wireless FocusPRO® 5-1-1
EM.HEAT Up to 2 Heat/ Programmable Thermostat;
2 Cool Conventional C7089R1013 Wireless Outdoor Sensor;
THM5320R1000 Equipment Interface Module;
C7735A1000 Return Air Sensor

See page 26 through page 33 for more RedLINK™ products

12 customer.honeywell.com 70-6910
Programmable Thermostats

Home Controls
FocusPRO® 6000 5-1-1 Day Programmable Thermostat
• Selectable to 5-1-1 (Weekdays, Saturday, Sunday) or 5-2
(Weekdays, Weekend) programmable thermostat.
• Large, clear, backlit display - easy to read in various lighting
conditions.
• Display size options - available in large screen or standard.
• Precise comfort control (±1 F) - maintains consistent comfort to the
highest level of accuracy.

Indoor Air Quality


• Simplified programming and operation.
• Easy change battery door - flip out door allows for easy battery
replacement without removing or disassembling the thermostat.
• Built in instructions - simple, pull out instruction manual.
Standard Display Large Display • Adaptive Intelligent Recovery® - ensures programmed temperature
is reached by programmed time.
The FocusPRO® programmable thermostat provides electronic • Temperature range stops - prevents user from setting the
control of 24 Vac conventional and heat pump systems or 750 mV temperature too high or too low.

Combustion Controls
heating systems.

Residential
Dimensions, Approximate: 3 9/16 in. high x 5 13/16 in. wide x Power Method: Battery or Hardwired
1 1/2 in. deep (91 mm high x 147 mm wide x 38 mm deep) Sensor Element: Thermistor
Color: Premier White® Mounting: Horizontal
Programmability: 5-1-1 Day Program or 5-2 Day Program
Changeover: Auto/Manual Selectable Accessories:
Electrical Ratings: 20 to 30 Vac or 750 mV 50002883-001 FocusPRO® 5000/6000 and PRO 3000/4000 Cover
Operating Humidity Range (% RH): 5 to 90% RH, non-condensing Plate Assembly
Differential Temperature: ± 1 F (±0.5 C) 50007298-001 12 pack of medium coverplates (5 in. x 6 7/8 in.)

Hydronic Controls
Currents (Cooling): 0.02 A to 1.0 A running Replacement Parts:
Currents (Heating): 0.02 A to 1.0 A running 50007072-001 Replacement Battery Holder for FocusPRO® TH5220,
Currents (Fan): 0.02 A to 0.5 A running TH5320, TH6110, TH6220, and TH6320 Thermostat
Frequency: 50 Hz; 60 Hz

Setting Temperature
Switch Positions Range
Terminal
Product Number Application System Fan Designations Stages (F) (C) Comments
TH6110D1005 Heat/Cool or Heat Pump HEAT-OFF- AUTO- Rc, R, W (O/B), Up to 1 Heat/1 Cool Heat: 40 F Heat: 4.5 C Standard display
without Auxiliary Heat COOL-AUTO ON Y, G, C to 90 F; to 32 C; size 3.75 sq. in.

Controls
Cool: 50 F Cool: 10 C

Water
to 99 F to 37 C
TH6110D1021 Heat/Cool or Heat Pump HEAT-OFF- AUTO- Rc, R, W (O/B), Up to 1 Heat/1 Cool Heat: 40 F Heat: 4.5 C Large display size
without Auxiliary Heat COOL-AUTO ON Y, G, C to 90 F; to 32 C; 5.09 sq. in.
Cool: 50 F Cool: 10 C
to 99 F to 37 C
TH6220D1002 Heat/Cool or Heat Pump HEAT-OFF- AUTO- Rc, R, W (O/B), Up to 2 Heat/1 Cool Heat: 40 F Heat: 4.5 C Standard display

Building Automation
with Auxiliary Heat COOL-AUTO- ON W2 (AUX), Y, Y2 Heat Pump; to 90 F; to 32 C; size 3.75 sq. in.
EM.HEAT (E), G, L, C Up to 2 Heat/2 Cool Cool: 50 F Cool: 10 C
Conventional to 99 F to 37 C
TH6220D1028 Heat/Cool or Heat Pump HEAT-OFF- AUTO- Rc, R, W (O/B), Up to 2 Heat/1 Cool Heat: 40 F Heat: 4.5 C Large display size
with Auxiliary Heat COOL-AUTO- ON W2 (AUX), Y, Y2 Heat Pump; to 90 F; to 32 C; 5.09 sq. in.
EM.HEAT (E), G, L, C up to 2 Heat/2 Cool Cool: 50 F Cool: 10 C
Conventional to 99 F to 37 C
TH6320U1000 Heat/Cool or Heat Pump HEAT-OFF- AUTO- Rc, R, W (O/B), Up to 3 Heat /2 Cool Heat: 40 F Heat: 4.5 C Large display size
with Auxiliary Heat COOL-AUTO- ON W2 (AUX/E), Y, Heat Pump; to 90 F; to 32 C; 5.09 sq. in.
EM.HEAT Y2, G, L, C Up to 2 Heat /2 Cool Cool: 50 F Cool: 10 C
Conventional to 99 F to 37 C

Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 13
Programmable Thermostats
PRO 4000 5-2 Day Programmable Thermostat
The PRO programmable series provides 24 Vac control for
conventional and heat pump systems.
• Weekday/Weekend programming - 5-2 (Weekdays, Weekend)
programming.
• Backlit digital display - both current and set temperatures are easy to
read in various lighting conditions.
• Precise comfort control [±1 F (± 0.5 C)] - maintains consistent
comfort to the highest level of accuracy.
• Basic operation - easy-to-use slide switches allow you to select the
heat or cool mode, and operate the fan.
• Built in instructions - simple, pull out instruction manual.
• Adaptive Intelligent Recovery® - ensures programmed temperature
is reached by programmed time.

Dimensions, Approximate: 3 13/16 in. high x 5 3/8 in. wide x Currents (Heating): 0.02 A to 1.0 A running
1 1/4 in. deep (97 mm high x 137 mm wide x 32 mm deep) Frequency: 50 Hz; 60 Hz
Display Size: 1.73 sq. in. Power Method: Dual Powered: Battery or Hardwire
Color: Premier White® Sensor Element: Thermistor
Programmability: 5-2 Day Program Mounting: Horizontal
Changeover: Manual
Electrical Ratings: 20 to 30 Vac or 750 mV Accessories:
Operating Humidity Range (% RH): 5 to 90% RH, non-condensing 50002883-001 FocusPRO® 5000/6000 and PRO 3000/4000 Cover
Differential Temperature: ± 1 F (±0.5 C) Plate Assembly
Currents (Cooling): 0.02 A to 1.0 A running 50007298-001 12 pack of medium coverplates (5 in. x 6 7/8 in.)

Switch Positions Setting Temperature Range


Terminal
Product Number Application System Fan Designations Stages (F) (C)
TH4110D1007 Heat/Cool or Heat Pump HEAT-OFF- AUTO-ON R, Rc, W, Y, G, O, 1 Heat/1 Cool Heat: 40 F to 90 F; Heat: 4.5 C to 32 C;
without Auxiliary Heat COOL B, C Cool: 50 F to 99 F Cool: 10 C to 37 C
TH4210D1005 Heat Pump Systems HEAT-OFF- AUTO-ON R, Y, AUX, E, G, 2 Heat/1 Cool Heat: 40 F to 90 F; Heat: 4.5 C to 32 C;
COOL-EM. HT O, B, L, C Heat Pump Cool: 50 F to 99 F Cool: 10 C to 37 C

Basic PRO 2000 Programmable Thermostat


The PRO programmable series provides 24 Vac control for
conventional and heat pump systems.
• Weekday/Weekend programming - 5-2 (Weekdays, Weekend)
programming.
• Backlit digital display - both current and set temperatures are easy to
read in various lighting conditions.
• Precise comfort control [±1 F (±0.5 C)] - maintains consistent comfort
to the highest level of accuracy.
• Basic operation - easy-to-use slide switches allow you to select the
heat or cool mode, and operate the fan.
• Adaptive Intelligent Recovery® - ensures programmed temperature
is reached by programmed time.

Dimensions, Approximate: 4 11/16 in. high x 2 7/8 in. wide x 1 1/8 in. Power Method: Dual Powered: Battery or Hardwire
deep (120 mm high x 74 mm wide x 28 mm deep) Sensor Element: Thermistor
Color: Premier White® Accuracy: ± 1 F (±0.5 C)
Programmability: 5-2 Day Program Switch Type: Relay
Changeover: Manual Mounting: Vertical
Electrical Ratings: 20 to 30 Vac or 750 mV
Operating Humidity Range (% RH): 5 to 90% RH, non-condensing
Accessories:
50022893-001 Premier White® cover plate 5 3/4 in. (146 mm) x 7 3/8 in.
Currents (Cooling): 0.02 A to 1.0 A running
(187 mm)
Currents (Heating): 0.02 A to 1.0 A running
Frequency: 50 Hz; 60 Hz

Switch Positions Setting Temperature Range


Terminal
Product Number Application System Fan Designations Stages (F) (C)
* TH2110D1009 Heat/Cool or Heat Pump HEAT-OFF- AUTO-ON R, C W, Y G, O/B 1 Heat/1 Cool Heat: 40 to 90 F; Heat: 4.5 to 32 C;
without Auxiliary Heat COOL Cool: 50 to 99 F Cool: 10 to 37 C
TH2210D1007 Heat Pump Systems HEAT-OFF- AUTO-ON R, C, Aux, Y, G, 2 Heat/1 Cool Heat: 40 F to 90 F; Heat: 4.5 C to 32 C;
COOL-EM. HT O/B Heat Pump Cool: 50 F to 99 F Cool: 10 C to 37 C
* TRADELINE models • SUPER TRADELINE models

14 customer.honeywell.com 70-6910
Temperature Sensors

Home Controls
C7089 Outdoor Sensor
Remote outdoor temperature sensor, when installed, the current
outdoor temperature is displayed. Also can be used to manage
dual fuel and lock-out expensive auxiliary heat in heat pump
applications.
• Mounting clip allows easy sensor positioning on siding or soffit.
• Includes 60 in. leadwires.
• Factory calibrated; no field calibration required.

Indoor Air Quality


• Maximum wire run of 200 feet.

Dimensions, Approximate: 2 1/4 in. x 3/8 in. with 60 in. leadwires. Ambient Temperature Range: -40 F to +128 F (-40 C to +53 C)
(57 mm x 10 mm with 1524 mm leadwires.) Mounting: Mounting Clip provided and screws provided.
Operating Humidity Range (% RH): 5 to 95% RH, non-condensing

Combustion Controls
Product Number Application Used With

Residential
* C7089A1002 Outdoor sensor for PC8900/W8900 Perfect Climate PC8900/W8900
Comfort Control Center
* C7089B1000 Outdoor sensor for Chronotherm IV thermostats and TZ-4 Chronotherm IV T8600 and T8500 Thermostat families and TZ-4 Zone
Zone Panel Panel; Chronotherm® IV T8600 and T8500 Thermostat families
C7089U1006 Outdoor sensor for VisionPRO and VisionPRO IAQ VisionPRO® Series Thermostats, VisionPRO® IAQ Thermostat
Thermostats
* TRADELINE models • SUPER TRADELINE models

Hydronic Controls
C7189 Remote Indoor Sensor
The Remote Indoor Temperature Sensor is used to sense
temperature remotely.
• Used to sense temperature if the thermostat is installed in a poor
temperature sensing location.
• Small remote temperature sensor to match any room decor.
• Easy to install and use.
• Factory calibrated; no field calibration required.

Controls
• Works with a maximum 200 foot wire run.

Water
Dimensions, Approximate: 1 1/2 in. wide x 2 1/4 in. high x 3/4 in. deep
(38 mm wide x 57 mm high x 19 mm deep)
Color: Premier White®
Operating Humidity Range (% RH): 5 to 95% RH, non-condensing
Ambient Temperature Range: 45 F to 88 F (7 C to 32 C)
Mounting: Mounts directly on the wall using mounting screws and

Building Automation
anchors provided

Setting Temperature Range


Product Number Application (F) (C) Used With
* C7189U1005 Remote Indoor Temperature Sensor for VisionPRO See Thermostats VisionPRO® and VisionPRO® IAQ Series
and VisionPRO IAQ Thermostats Thermostats
* TRADELINE models • SUPER TRADELINE models

Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 15
Non-Programmable Thermostats
Wireless System Kits
• EQUIPMENT INTERFACE MODULE (EIM): All HVAC equipment is
wired to the module. Module receives communication from the
wireless devices.
• RETURN AIR SENSOR: Works with the Equipment Interface
Module to maintain safe indoor temperatures if power is lost at the
wireless thermostat. Maintains 62 F for heating and 82 F for cooling.
• PORTABLE COMFORT CONTROL: Allows homeowners to sense
and control temperature from any room in the home to provide
comfort where they spend their time. Manage comfort and energy
savings from one convenient control. Touchscreen interface with
backlit display. Displays outdoor temperature and humidity. 1 year
battery life. 2 month low battery warning.
• WIRELESS OUTDOOR SENSOR: Reliable performance in all
climates. Installs in minutes. Up to 5 year battery life. 2 month low
battery warning.
• RedLINK™ WIRELESS TECHNOLOGY: Powered by RedLINK™
reliability. No interference with other wireless devices in the home.

Everything you need to relocate thermostat or upgrade equipment


without running new wires. Includes the Portable Comfort Control
to sense and control temperature from any room and a Wireless
Outdoor sensor to display outdoor temperature and humidity on all
devices.
• WIRELESS FocusPRO® THERMOSTAT: Same great features of the
FocusPRO® thermostat - now wireless. Installs in minutes. Displays
outdoor temperature and humidity. 1 year battery life. 2 month low
battery warning. Dual Fuel enabled.

Application: Gas, oil, electric, heat pump, forced warm air, hot water, Accessories:
steam or gravity 50002883-001 FocusPRO® 5000/6000 and PRO 3000/4000 Cover
Electrical Ratings: Plate Assembly
Equipment Interface Module--18 to 30 Vac, 50 Hz; 60 Hz 50007298-001 12 pack of medium coverplates (5 in. x 6 7/8 in.)
Changeover: Auto/Manual Selectable
Currents (Cooling): 1.0 A running Replacement Parts:
Currents (Heating): 1.0 A running 50007072-001 Replacement Battery Holder for FocusPRO® TH5220,
Currents (Fan): 0.6 A running TH5320, TH6110, TH6220, and TH6320 Thermostat
Power Method: Thermostat--Battery

Switch Positions
Product Number System Fan Terminal Designations Stages Includes
YTH5320R1017 HEAT-OFF- AUTO-ON C, R, Rc, Rh, W-O/B, W2- Up to 3 Heat/ REM5000R1001 Personal Comfort Station;
COOL-AUTO- Aux/E, Y, Y2, G, L, RAS 2 Cool Heat Pump; C7089R1013 Wireless Outdoor Sensor;
EM.HEAT Up to 2 Heat/ TH5320R1002 Wireless FocusPRO® Non-
2 Cool Conventional Programmable Thermostat;
THM5320R1000 Equipment Interface Module;
C7735A1000 Return Air Sensor

See page page 26 through page 33 for more RedLINK™ products

16 customer.honeywell.com 70-6910
Non-Programmable Thermostats

Home Controls
FocusPRO® 5000 Digital Non-Programmable Thermostats
The FocusPRO® non-programmable digital thermostat provides
Standard Display Large Display control when connected to an EnviraZone Zone Panel or an
EnviraCOM equipment interface module or an EnviraCOM control
board at the equipment.
• Non-programmable digital thermostat.
• Large, clear, backlit display - easy to read in various lighting
conditions.

Indoor Air Quality


• Display size options - available in large screen or standard.
• Precise comfort control (±1 F) - maintains consistent comfort to the
highest level of accuracy.
• Easy change battery door - flip out door allows for easy battery
replacement without removing or disassembling the thermostat.
• Up to 3 Heat/2 Cool Heat Pump or Up to 2 Heat/2 Cool
TH5110 Conventional.
• Dual-powered (battery and/or hardwire).

Combustion Controls
Residential
TH5220

Hydronic Controls
Dimensions, Approximate: Sensor Element: Thermistor
TH5110: 3 7/16 in. high x 4 1/2 in. wide x 1 5/16 in. deep Color: Premier White®
(86 mm high x 114 mm wide x 33 mm deep) Mounting: Horizontal
TH5220: 3 9/16 in. high x 5 13/16 in. wide x 1 1/2 in. deep
(91 mm high x 147 mm wide x 38 mm deep) Accessories:
Electrical Ratings: 20 to 30 Vac or 750 mV 50001137-001 FocusPRO® TH5110 Cover Plate Assembly
Changeover: Auto/Manual Selectable 50002883-001 FocusPRO® 5000/6000 and PRO 3000/4000 Cover
Operating Humidity Range (% RH): 5 to 90% RH, non-condensing Plate Assembly
Accuracy: ±1 F (±0.5 C) 50007297-001 12 pack of small coverplates (4 5/16 in. x 5 1/2 in.)
50007298-001 12 pack of medium coverplates (5 in. x 6 7/8 in.)

Controls
Cycles per Hour: Heating 1-12 CPH; Cooling 1-6 CPH

Water
Switch Type: Relay Replacement Parts:
Cooling: 1.0 A running 50000951-001 Replacement Battery Holder for FocusPRO® TH5110
Heating: 1.0 A running Thermostat
Fan: 0.5A running 50007072-001 Replacement Battery Holder for FocusPRO® TH5220,
Frequency: 50 Hz; 60 Hz TH5320, TH6110, TH6220, and TH6320 Thermostat
Power Method: Dual Powered: Battery or Hardwire

Building Automation
Switch Positions Setting Temperature Range
Terminal
Product Number Application System Fan Designations Stages (F) (C) Comments
TH5110D1006 Up to 1 Heat/1 Cool HEAT-OFF- AUTO-ON R, Rc, C, W Up to 1 Heat/ Heat: 40 F to 90 F; Heat: 4.5 C to 32 C; Standard
Conventional COOL- (O/B), Y, G 1 Cool Cool: 50 F to 99 F Cool: 10 C to 37 C display size
Systems and Heat AUTO 1.95 sq. in.
Pumps with No
Auxiliary Heat
TH5110D1022 Up to 1 Heat/1 Cool HEAT-OFF- AUTO-ON R, Rc, C, W Up to 1 Heat/ Heat: 40 F to 90 F; Heat: 4.5 C to 32 C; Large
Conventional COOL- (O/B), Y, G 1 Cool Cool: 50 F to 99 F Cool: 10 C to 37 C display size

Components
Commercial
Systems and Heat AUTO 2.98 sq. in.
Pumps with No
Auxiliary Heat
TH5220D1003 Up to 2 Heat/2 Cool HEAT-OFF- AUTO-ON Rc, R, W (O/B), Up to 2 Heat/ Heat: 40 F to 90 F; Heat: 4.5 C to 32 C; Standard
Conventional COOL- W2 (AUX), Y, Y2 2 Cool Cool: 50 F to 99 F Cool: 10 C to 37 C display size
Systems; Up to 2 AUTO- (E), G, L, C 3.75 sq. in.
Heat/1 Cool Heat EM.HEAT
Pumps
Pneumatic Controls

TH5220D1029 Up to 2 Heat/2 Cool HEAT-OFF- AUTO-ON Rc, R, W (O/B), Up to 2 Heat/ Heat: 40 F to 90 F; Heat: 4.5 C to 32 C; Large
Conventional COOL- W2 (AUX), Y, Y2 2 Cool Cool: 50 F to 99 F Cool: 10 C to 37 C display size
Systems; Up to 2 AUTO- (E), G, L, C 5.09 sq. in.
Heat/1 Cool Heat EM.HEAT
Pumps
TH5320U1001 Up to 2 Heat/2 Cool HEAT-OFF- AUTO-ON Rc, R, W (O/B), Up to 3 Heat/ Heat: 40 F to 90 F; Heat: 4.5 C to 32 C; Large
Conventional COOL- W2 (AUX/E), Y, 2 Cool Cool: 50 F to 99 F Cool: 10 C to 37 C display size
Systems; Up to 3 AUTO- Y2, G, L, C 5.09 sq. in.
Heat/2 Cool Heat EM.HEAT
Industrial Combustion

Pumps
Controls

70-6910 17
Non-Programmable Thermostats
PRO 3000 Non-Programmable Thermostats
The PRO series provides non-programmable thermostats for 24
Vac conventional and heat pump systems or 750 mV heating
systems.
• Non-programmable digital thermostat.
• Backlit digital display - both current and set temperatures are easy to
read in various lighting conditions.
• Shows both current and set temperatures at the same time.
• Precise comfort control [± 1 F (± 0.5 C)] - maintains consistent
comfort to the highest level of accuracy.
• Basic operation - easy-to-use slide switches allow you to select the
heat or cool mode, and operate the fan.

Dimensions, Approximate: 3 13/16 in. high x 5 3/8 in. wide x Frequency: 50 Hz; 60 Hz
1 1/4 in. deep (97 mm high x 137 mm wide x 32 mm deep) Power Method: Dual Powered: Battery or Hardwire
Display Size: 1.32 sq. in. Sensor Element: Thermistor
Electrical Ratings: 20 to 30 Vac or 750 mV Color: Premier White®
Changeover: Manual Mounting: Horizontal
Operating Humidity Range (% RH): 5 to 90% RH, non-condensing
Accuracy: ±1 F (±0.5 C) Accessories:
Cycles per Hour: Heating 1-12 CPH; Cooling 1-6 CPH 50002883-001 FocusPRO® 5000/6000 and PRO 3000/4000 Cover
Switch Type: Relay Plate Assembly
Current (Cooling): 0.02 A to 1.0 A running 50007298-001 12 pack of medium coverplates (5 in. x 6 7/8 in.)
Current (Heating): 0.02 A to 1.0 A running

Switch Positions Setting Temperature Range


Terminal
Product Number Application System Fan Designations Stages (F) (C)
TH3110D1008 1 Heat/1 Cool Conventional HEAT-OFF-COOL AUTO-ON R, Rc, W, Y, G, 1 Heat/1 Cool Heat: 40 F to 90 F; Heat: 4.5 C to 32 C;
Systems and Heat Pumps O, B, C Cool: 50 F to 99 F Cool: 10 C to 37 C
with No Auxiliary Heat
TH3210D1004 2 Heat/1 Cool Heat Pump HEAT-OFF- AUTO-ON R, Y, AUX, E, G, 2 Heat/1 Cool Heat: 40 F to 90 F; Heat: 4.5 C to 32 C;
Systems COOL-EM. HT O, B, L, C Heat Pump Cool: 50 F to 99 F Cool: 10 C to 37 C

18 customer.honeywell.com 70-6910
Non-Programmable Thermostats

Home Controls
PRO Basic 1000 Non-Programmable Thermostats
The PRO non-programmable digital thermostat provides electronic
control of 24 Vac conventional and heat pump systems or 750 mV
heating systems.
• Non-programmable digital thermostat.
• Easy-to-read backlit display - easy to read in various lighting
conditions.
• Precise comfort control [±1 F (±0.5 C)] - maintains consistent comfort

Indoor Air Quality


to the highest level of accuracy.
• Basic operation - easy-to-use slide switches allow you to select the
heat or cool mode, and operate the fan.

Combustion Controls
Residential
Dimensions, Approximate: 4 11/16 in. high x 2 7/8 in. wide x 1 1/8 in. Frequency: 50 Hz; 60 Hz
deep (120 mm high x 74 mm wide x 28 mm deep) Power Method: Dual Powered: Battery or Hardwire
Display Size: 1.32 sq. in. Sensor Element: Thermistor
Electrical Ratings: 20 to 30 Vac or 750 mV Color: Premier White®

Hydronic Controls
Changeover: Manual Mounting: Vertical
Operating Humidity Range (% RH): 5 to 90% RH, non-condensing
Accuracy: ±1 F (±0.5 C) Accessories:
Cycles per Hour: Heating 2-6 CPH 50022893-001 Premier White® cover plate 5 3/4 in. (146 mm) x 7 3/8 in.
Switch Type: Relay (187 mm)
Heating: 0.02 A to 1.0 A running

Switch Positions Setting Temperature Range


Terminal
Product Number Application System Fan Designations Stages (F) (C) Comments
TH1100D1001 Heat Only HEAT-OFF — R, C, W, 1 Heat Selectable Heat: Selectable Heat Adjustable Temperature

Controls
40 F to 90 F or 4.5 C to 32 or Scale: Standard selection

Water
35 F to 90 F 1.5 C to 32 C of 40 to 90F or Garage
selection of 35 to 90F
TH1110D1000 1 Heat/1 Cool HEAT-OFF- AUTO-ON R, C, W, Y, G, 1 Heat/ Heat: Heat: —
Conventional COOL O/B 1 Cool 40 F to 90 F; 4.5 C to 32 C;
Systems and Heat Cool: Cool:
Pumps with No 50 F to 99 F 10 C to 37 C

Building Automation
Auxiliary Heat
TH1210D1008 2 Heat/1 Cool Heat HEAT-OFF- AUTO-ON R, C, Aux, Y, G, 2 Heat/ Heat: Heat: —
Pump Systems COOL- O/B 1 Cool 40 F to 90 F; 4.5 C to 32 C;
EM. HT Heat Cool: Cool:
Pump 50 F to 99 F 10 C to 37 C

Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 19
Non-Programmable Thermostats
T8775A,C The Digital Round® Non-Programmable Thermostats
The Digital Round® Thermostats provide 24V control of heating
only or heat/cool systems.
• Attractive styling complements any decor.
• One-touch backlit display.
• Familiar twist-to-see operation. Available in Heat/Cool and Heat
Only models.

Dimensions, Approximate: 3 11/16 in. diameter x 1 7/16 in. deep Sensor Element: Thermistor
(94 mm diameter x 37 mm deep) Color: Premier White®
Display Size: 0.75 sq in. Mounting: Round
Operating Humidity Range (% RH): 5 to 90% RH (non-condensing) Comments: Large easy-to-see backlit display
Accuracy: ±1 F (±0.5 C) Includes: Wallplate, resistor assembly, mounting screws and wall
Cycles per Hour: Adjustable 1, 3, 6, 9 anchors
Switch Type: Electronic
Cooling: 0.02A to 1.5A running; 6.0A inrush Accessories:
Heating: 0.02A to 1.5A running, 3.5A inrush 50000066-001 Decorative Cover Plate for T8775 or T87K,N
Fan: 0.02A to 0.5A running, 2.5A inrush Replacement Parts:
Frequency: 60 Hz 32007680-001 Replacement Cover for T8775
Power Method: Powered through system heating controls

Switch Positions Setting Temperature Range


Terminal Electrical
Product Number Application System Fan Designations Stages (F) (C) Ratings
T8775A1009 24 Vac gas or oil heat only systems — — R, W 1 Heat 40 to 90 4.5 to 32 18 to 30
Vac
T8775C1005 1 Heat/1 Cool Conventional Systems HEAT-OFF- AUTO- R, Rc, W, Y, G, 1 Heat/ 40 to 90 in heat; 4.5 to 32 in heat; 18 to 30
and Heat Pumps with No Auxiliary Heat COOL ON O, B 1 Cool 45 to 99 in cool 7 to 37 in cool Vac

20 customer.honeywell.com 70-6910
Non-Programmable Thermostats

Home Controls
T87K,N The Round®
The Round® thermostats provide electronic control of 24Vac
heating and cooling systems with the classic twist to set dial.
• Mercury Free
• Classic Styling
• Premier White®
• The T87K heat only works with 2 or 3 wire heat-only systems

Indoor Air Quality


Electrical Ratings: 20 to 30 Vac
Operating Humidity Range (% RH): 5 to 90% RH (non-condensing)
Accuracy: ±1 F (± 0.5 C)
Cycles per Hour: Adjustable 1, 3, 5, 9
Switch Type: Relay
Heating: 0.02 A to 1.0 A running
Frequency: 50 Hz; 60 Hz
Power Method: Battery assisted power stealing
Heat Only 1 Heat/1 Cool Sensor Element: Thermistor

Combustion Controls
Color: Premier White®

Residential
Mounting: Round
Accessories:
50000066-001 Decorative Cover Plate for T8775 or T87K,N
50010944-001 Range Stop Assembly

Hydronic Controls
1 Heat/1 Cool,
Easy To See

Setting
Switch Temperature Dimensions,

Controls
Water
Positions Range Approximate
Terminal
Product Number Application System Fan Designations Stages (F) (inch) (mm) Includes Comments
T87K1007 Heat Only — — R, W, Y 1 Heat 40 to 90 3 11/16 in. 94 mm — —
diameter diameter
x 1 3/4 in. x 45 mm
deep deep

Building Automation
T87N1000 1 Heat/1 Cool HEAT- AUTO- R, Rc, W, Y, G, 1 Heat/ 40 to 90 3 11/16 in. 94 mm — —
Conventional OFF- ON O, B 1 Cool diameter diameter
Systems and COOL x 1 3/4 in. x 45 mm
Heat Pumps with deep deep
No Auxiliary Heat
T87N1026 1 Heat/1 Cool HEAT- AUTO- R, Rc, W, Y, G, 1 Heat/ 40 to 90 4 in. 102 mm 6 in. (152 mm) EASY-TO-SEE
Conventional OFF- ON O, B 1 Cool diameter diameter cover ring and model with Large
Systems and COOL x 1 3/4 in. x 45 mm switch raised markings and
Heat Pumps with deep deep position labels a click at each 2
No Auxiliary Heat degree setpoint
change

Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 21
Non-Programmable Thermostats
Mercury Free T822 Econo Thermostats
Thermostats provide 24 Vac control of heating or cooling systems.
• Vented cover for improved temperature sensing.
• Setting lever and thermometer scale on thermostat cover.
• Mounts directly on the wall or on vertical outlet box.
• Integrated thermometer and setting scale.

Dimensions, Approximate: 4 3/4 in. high x 2 7/8 in. wide x 1 3/8 in.
deep (121 mm high x 73 mm wide x 35 mm deep)
Electrical Ratings: 20 to 30 Vac
Accuracy: ±2 F (±1 C)
Switch Type: Precision Snap Action
Switching Action: SPST
Heating: 0.02 A to 1.0 A running
Sensor Element: Bimetal
Color: Premier White®
Mounting: Vertical
No Heat-Off Heat-Off Dual Scale

Switch Setting Temperature


Positions Range
Terminal
Product Number Application System Designations Stages (F) (C) Description
T822K1000 Heat Only HEAT-OFF R, W 1 Heat 45 to 95 — Mercury Free Heat Only Thermostat with
Positive Off for control of single stage low
voltage heating systems
T822K1018 Heat Only — R, W 1 Heat 45 to 95 — Mercury Free Heat Only Thermostat for
control of single stage low voltage heating
systems
T822K1042 Heat Only HEAT-OFF R, W 1 Heat 35 F to 85 F — Mercury Free Heat Only Thermostat with
Low Temperature Scale, Ideal for Garages.
Heat/Off. For control of heat only low
voltage systems.
T822L1000 Cool Only or Heat — R, Y 1 Cool 45 to 95 7 to 32 Temperature scale in Fahrenheit and
Only for Normally Celsius; Mercury Free Cool Only
Open Hot Water Zone Thermostat control of single stage low
Valves voltage cooling systems

22 customer.honeywell.com 70-6910
Non-Programmable Thermostats

Home Controls
Mercury Free T827 Econo Thermostats
The EconoStat series mechanical thermostats provide control of
12 Vdc or 750 mV heat only systems.
• Integrated thermometer and temperature setting scale.
• Precise Snap-action switch.
• Mount directly on wall or outlet box.
• Includes dealer logo pocket.

Indoor Air Quality


Dimensions, Approximate: 4 3/4 in. high x 2 7/8 in. wide x 1 3/8 in.
deep (121 mm high x 73 mm wide x 35 mm deep)
Accuracy: ±2 F (±1 C)
Switch Type: Precision Snap Action
Switching Action: SPST
Sensor Element: Bimetal
Color: Premier White®
Mounting: Vertical

Combustion Controls
Residential
Switch Setting Temperature
Positions Range
Terminal
Product Number Application System Designations Stages (F) (C) Description
T827K1009 Heat Only HEAT-OFF R, W 1 Heat 45 to 95 — Mercury Free Heat Only Thermostat with
Positive Off for control of single stage low

Hydronic Controls
voltage heating systems

Mercury Free T834; T8034 Econo Thermostats


Thermostats for low voltage control of single-stage heating,
cooling or heating-cooling systems.
• Integrated thermometer and temperature setting scale.
• Precise Snap-action switch.
• Mount directly on wall or outlet box.
• Includes dealer logo pocket.

Controls
Water
Dimensions, Approximate: 4 3/4 in. high x 2 7/8 in. wide x 1 3/8 in.
deep (121 mm high x 73 mm wide x 35 mm deep)
Electrical Ratings: 20 to 30 Vac
Accuracy: ±2 F (±1 C)
Switch Type: Precision Snap Action
Switching Action: SPST

Building Automation
Cooling: 0.02 A to 1.0 A running
Heating: 0.02 A to 1.0 A running
Sensor Element: Bimetal-+
Color: Premier White®
Mounting: Vertical
Cool Only 1 Heat/1 Cool Accessories:
50019661-001 Range Stop Assembly for Econostat

Setting

Components
Switch Positions Temperature Range

Commercial
Terminal
Product Number Application System Fan Designations Stages (F) (C) Description
T834L1004 Cool Only COOL-OFF AUTO-ON R, Y, G, O 1 Cool 45 to 95 7 to 32 Temperature scale in
Fahrenheit and Celsius;
Mercury Free Cool Only
Thermostat with Positive
Off for control of single
stage low voltage
Pneumatic Controls

cooling systems
T834N1002 1 Heat/1 Cool HEAT-OFF- AUTO-ON R, Rc, W, Y, G, 1 Heat/1 Cool 45 to 95 — Mercury Free 1Heat/
Conventional Systems COOL O, B 1Cool Stage Thermostat
and Heat Pumps with for control of single
No Auxiliary Heat stage low voltage
heating/cooling systems
Industrial Combustion
Controls

70-6910 23
Non-Programmable Thermostats
T812; TS812 Heating and/or Cooling Thermostats
Thermostats for low voltage control of single-stage heating,
cooling or heating-cooling systems.
• Snap-acting bimetal switch uses no mercury and does not require
leveling.
• Thermostat is streamlined and economical.
• Model available for 12 Vdc (T812B) and 750 mV (TS812).
• Includes dealer logo pocket.

Heat Only 1 Heat/1 Cool

Dimensions, Approximate: 3 1/8 in. high x 3 1/8 in. wide x 7/8 in. deep Sensor Element: Bimetal
(79 mm high x 79 mm wide x 23 mm deep) Color: Premier White®
Operating Humidity Range (% RH): 5 to 90% RH Mounting: Square
Setting Temperature Range: 45 to 95 F (7 to 35 C)
Accuracy: ±3 F (±1.5 C) Accessories:
Switch Type: Snap action 50005625-001 Premier White® Cover Plate Assembly 4 3/4 in. (120
Heating: 1.0A running, 2.5A inrush at 24 Vac mm) x 4 3/4 in. (120 mm)
Fan: 1.0A running, 5A inrush at 24 Vac

Switch Positions
Terminal Electrical Switching
Product Number Application System Fan Designations Stages Ratings Action Description
T812A1002 Heat Only — — W, R 1 Heat 18 to 30 SPST Premier White 1 Heat Stage Thermostat
Vac with W,R terminals for 24 volt control of
heating only systems
T812A1010 Heat Only Positive — W, R 1 Heat 18 to 30 SPST Premier White 1 Heat Stage Thermostat
Off Vac with W,R terminals for 24 volt control of
heating only systems
T812B1001 Heat Only - 12 Positive — W, R 1 Heat 12 Vdc SPST Premier White 1 Heat Stage Thermostat
Vdc Off with W,R terminals for 12 Vdc control of
heating only systems
T812C1000 1 Heat/1 Cool OFF- AUTO- R, W, Y, G 1 Heat/ 18 to 30 SPDT Premier White 1 Heat/1 Cool Stage
Conventional HEAT- ON 1 Cool Vac Thermostat for 24 Vac heating and cooling
Systems COOL systems
T812D1009 Cool Only — — R, Y 1 Cool 18 to 30 SPST Premier White 1 Cool Stage Thermostat
Vac with Y,R terminals for 24 volt control of
cooling only systems
* TS812A1007 Heat Only - Positive — R, W 1 Heat 750 mV SPST Premier White 1 Heat Stage Thermostat
Millivolt Off with R,W terminals for heat only 750 mV
applications
* TRADELINE models • SUPER TRADELINE models

24 customer.honeywell.com 70-6910
Freeze Warning

Home Controls
S483 Winter Watchman
Used as a freeze warning device. Completes circuit to household
lamp on temperature fall, indicating inoperative heating
equipment.
• Plugs directly into wall outlet.
• Lamp plugs into receptacle at bottom of Winter Watchman device.
• Useful when house is unoccupied to notify a neighbor of a
temperature drop so heating source fault can be rectified before

Indoor Air Quality


freeze-up occurs.
• Not precision calibrated for use as a thermostat.

Dimensions, Approximate: 3 3/8 in. high x 2 1/8 in. wide x 13/16 in. Switching Action: SPST

Combustion Controls
deep (86 mm high x 54 mm wide x 21mm deep) Heating: 1.0A

Residential
Electrical Ratings: Load: 120W maximum for incandescent lamp load Frequency: 60 Hz
only. Sensor Element: Bimetal
Accuracy: ±5 F (±3 C) Color: Beige
Ambient Temperature Range: 30 F to 60 F (-1 C to +16 C) Mounting: Vertical Mount

Setting Temperature Range


Product Number Application (F) (C)

Hydronic Controls
S483B1002 Incandescent Lamp 30 to 60 -1 C to 16 C

Controls
Water
Building Automation
Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 25
RedLINK™ Products
Prestige™ Comfort System
• Large, easy-to-read backlit full color display shows current indoor
temperature and humidity, temperature setting, date and time on the
home screen. Also displays outdoor temperature and humidity on
home screen (if wireless outdoor sensor is installed)
• Adjustable backlight level allows thermostat to be on full brightness
at all times or dim to the brightness level of choice when the
thermostat is not being used
• Interview-Based Programming wizard to easily and confidently
schedule thermostat temperatures and times
• USB Port allows downloading of installer settings to quickly and
consistently perform setup of thermostats in similar applications
• USB Port also allows easy setup of dealer logo and contact
information on thermostat screen
High Definition Color Touchscreen Thermostat • Real-Time Clock keeps time during power failure; automatically
updates for daylight saving time
• Precise Temperature Control (± 1×F) for reliable and consistent
temperature.
• Multiple HOLD options allows modification of schedule as needed
• Change Reminders to inform it is time to replace Air Filter, humidifier
pad, ultraviolet bulb or batteries in connected devices
• RedLINK™ Enabled to communicate with compatible wireless
devices
• Kit Includes Portable Comfort Control, Wireless Outdoor Sensor and
Prestige™ HD Thermostat

Standard Definition Touchscreen Thermostat


The Prestige™ HD thermostat provides control of 24Vac of heating
and cooling systems. RedLINK™ enabled to work with compatible
wireless accessories. The Prestige™ HD Thermostat Kits contains
Wireless Outdoor Sensor and High Definition (HD) Color
Touchscreen Thermostat.

Application: Up to 2 Heat/2 Cool Conventional Systems Operating Temperature Range: 32 F to 120 F (0 C to 48.9 C)
Up to 3 Heat/2 Cool Heat Pumps Stages: Up to 3 Heat/2 Cool Heat Pump
Dimensions, Approximate: 3 15/16 in. high, 6 7/8 in. wide, or Up to 2 Heat/2 Cool Conventional
1 1/2 in. deep (100 mm. high, 175 mm. wide, 38 mm. deep) Power Method: Hardwired
Display Size: 8.06 sq. in. Outdoor Sensor: Yes, optional
Color: Arctic White Remote Sensor: No
Programmability: 7-Day Multiple Day Programming or Non- Comments: Tri-Lingual Display (selectable for English, French or
Programmable Spanish)
Changeover: Auto or Manual Used With: RedLINK™ enabled thermostats and accessories
Electrical Connections: Screw terminals
Electrical Ratings: 18 to 30 Vac Accessories:
Frequency: 50 Hz; 60 Hz 50028399-001 Cover plate for Prestige Thermostats 7 7/8 in. (200 mm)
Voltage: 18 to 30 Vac x 5 1/2 in. (140 mm)
Operating Humidity Range (% RH): 0 to 90% RH, non-condensing C7089R1013 Senses outdoor temperature and humidity to display on
Humidity Setting Range: Cooling: 40 to 80% RH. Heating: 10 to 80% RedLINK™ enabled thermostats and accessories.
RH. REM5000R1001 Use the Portable Comfort Control anywhere in the
Dehumidification Setting Range: 40 to 80% RH home to experience a new level of comfort and convenience.
Humidification Setting Range: 10 to 60% RH. RedLINK™ Enabled. Works in both zoned and non-zoned
Setting Temperature Range: applications.
Heat: 40 F to 90 F; Cool 60 F to 99F THP9045A1007 THP9045 WireSaver
(Heat: 4.5 C to 32.0 C; Cool: 15.5 C to 37.0 C)

Switch Positions
Product Number System Fan Terminal Designations Includes
THX9321R1008 HEAT-OFF-COOL- AUTO-ON- C, R, Rc, W-O/B, W2-AUX/E, Y, Y2, G, Standard Definition Touchscreen Thermostat
AUTO-EM.HEAT CIRC L, K, HUM, HUM, DHM, DHM
THX9321R5000 HEAT-OFF-COOL- AUTO-ON- C, R, Rc, W-O/B, W2-AUX/E, Y, Y2, G, High Definition Color Touchscreen Thermostat
AUTO-EM.HEAT CIRC L, K, HUM, HUM, DHM, DHM
YTHX9321R1000 HEAT-OFF-COOL- AUTO-ON- C, R, Rc, W-O/B, W2-AUX/E, Y, Y2, G, Standard Definition Touchscreen Thermostat;
AUTO-EM.HEAT CIRC L, K, HUM, HUM, DHM, DHM REM5000R1001 Portable Comfort Control and
C7089R1013 Wireless Outdoor Sensor
YTHX9321R1011 HEAT-OFF-COOL- AUTO-ON- C, R, Rc, W-O/B, W2-AUX/E, Y, Y2, G, Standard Definition Touchscreen Thermostat;
AUTO-EM.HEAT CIRC L, K, HUM, HUM, DHM, DHM C7089R1013 Wireless Outdoor Sensor
YTHX9321R5003 HEAT-OFF-COOL- AUTO-ON- C, R, Rc, W-O/B, W2-AUX/E, Y, Y2, G, High Definition Color Touchscreen Thermostat;
AUTO-EM.HEAT CIRC L, K, HUM, HUM, DHM, DHM REM5000R1001 Portable Comfort Control and
C7089R1013 Wireless Outdoor Sensor
YTHX9321R5012 HEAT-OFF-COOL- AUTO-ON- C, R, Rc, W-O/B, W2-AUX/E, Y, Y2, G, High Definition Color Touchscreen Thermostat;
AUTO-EM.HEAT CIRC L, K, HUM, HUM, DHM, DHM C7089R1013 Wireless Outdoor Sensor

26 customer.honeywell.com 70-6910
RedLINK™ Wireless Products

Home Controls
Wireless System Kits
Everything you need to relocate thermostat or upgrade equipment
without running new wires. Includes the Portable Comfort Control
to sense and control temperature from any room and a Wireless
Outdoor sensor to display outdoor temperature and humidity on all
devices.
• WIRELESS FocusPRO® THERMOSTAT: Same great features of the
FocusPRO® thermostat - now wireless. Installs in minutes. Displays

Indoor Air Quality


outdoor temperature and humidity. 1 year battery life. 2 month low
battery warning. Dual Fuel enabled.
• EQUIPMENT INTERFACE MODULE (EIM): All HVAC equipment is
wired to the module. Module receives communication from the
wireless devices.
• RETURN AIR SENSOR: Works with the Equipment Interface
Module to maintain safe indoor temperatures if power is lost at the
wireless thermostat. Maintains 62 F for heating and 82 F for cooling.
• PORTABLE COMFORT CONTROL: Allows homeowners to sense

Combustion Controls
and control temperature from any room in the home to provide
comfort where they spend their time. Manage comfort and energy

Residential
savings from one convenient control. Touchscreen interface with
backlit display. Displays outdoor temperature and humidity. 1 year
battery life. 2 month low battery warning.
• WIRELESS OUTDOOR SENSOR: Reliable performance in all
climates. Installs in minutes. Up to 5 year battery life. 2 month low
battery warning.
• RedLINK™ WIRELESS TECHNOLOGY: Powered by RedLINK™
reliability. No interference with other wireless devices in the home.

Hydronic Controls
Application: Gas, oil, electric, heat pump, forced warm air, hot water, Accessories:
steam or gravity 50002883-001 FocusPRO® 5000/6000 and PRO 3000/4000 Cover
Electrical Ratings:

Controls
Plate Assembly

Water
Equipment Interface Module--18 to 30 Vac, 50 Hz; 60 Hz 50007298-001 12 pack of medium coverplates (5 in. x 6 7/8 in.)
Changeover: Auto/Manual Selectable
Current (Cooling): 1.0 A running Replacement Parts:
Current (Heating): 1.0 A running 50007072-001 Replacement Battery Holder for FocusPRO® TH5220,
Current (Fan): 0.6 A running TH5320, TH6110, TH6220, and TH6320 Thermostat
Power Method: Thermostat--Battery

Building Automation
Switch Positions
Product Number System Fan Terminal Designations Stages Includes
YTH5320R1017 HEAT-OFF- AUTO-ON C, R, Rc, Rh, W-O/B, W2-Aux/E, Up to 3 Heat/2 Cool REM5000R1001 Personal Comfort Station;
COOL-AUTO- Y, Y2, G, L, RAS Heat Pump; C7089R1013 Wireless Outdoor Sensor;
EM.HEAT Up to 2 Heat/2 Cool TH5320R1002 Wireless FocusPRO® Non-
Conventional Programmable Thermostat;
THM5320R1000 Equipment Interface Module;
C7735A1000 Return Air Sensor
YTH6320R1015 HEAT-OFF- AUTO-ON C, R, Rc, Rh, W-O/B, W2-Aux/E, Up to 3 Heat/2 Cool REM5000R1001 Personal Comfort Station;

Components
Commercial
COOL-AUTO- Y, Y2, G, L, RAS Heat Pump; TH6320R1004 Wireless FocusPRO® 5-1-1
EM.HEAT Up to 2 Heat/2 Cool Programmable Thermostat;
Conventional C7089R1013 Wireless Outdoor Sensor;
THM5320R1000 Equipment Interface Module;
C7735A1000 Return Air Sensor
Pneumatic Controls
Industrial Combustion
Controls

70-6910 27
RedLINK™ Wireless Products
Wireless Thermostat Kits with Outdoor Sensor
Everything you need to relocate thermostat or upgrade equipment
without running new wires. Includes Wireless Outdoor Sensor to
display outdoor temperature and humidity on all devices.
• WIRELESS FocusPRO® THERMOSTAT: Same great features of the
FocusPRO® thermostat - now wireless. Installs in minutes. Displays
outdoor temperature and humidity. 1 year battery life. 2 month low
battery warning. Dual Fuel enabled.
• EQUIPMENT INTERFACE MODULE (EIM): All HVAC equipment is
wired to the module. Module receives communication from the
wireless devices.
• RETURN AIR SENSOR: Works with the Equipment Interface
Module to maintain safe indoor temperatures if power is lost at the
wireless thermostat. Maintains 62 F for heating and 82 F for cooling.
• WIRELESS OUTDOOR SENSOR: Reliable performance in all
climates. Installs in minutes. Up to 5 year battery life. 2 month low
battery warning.
• RedLINK™ WIRELESS TECHNOLOGY: Powered by RedLINK™
reliability. No interference with other wireless devices in the home.
• reliability. No interference with other wireless devices in the home.

Application: Gas, oil, electric, heat pump, forced warm air, hot water, Accessories:
steam or gravity 50002883-001 FocusPRO® 5000/6000 and PRO 3000/4000 Cover
Electrical Ratings: Plate Assembly
Equipment Interface Module--18 to 30 Vac, 50 Hz; 60 Hz 50007298-001 12 pack of medium coverplates (5 in. x 6 7/8 in.)
Changeover: Auto/Manual Selectable REM5000R1001 Use the Portable Comfort Control anywhere in the
Current (Cooling): 1.0 A running home to experience a new level of comfort and convenience.
Current (Heating): 1.0 A running RedLINK™ Enabled. Works in both zoned and non-zoned
Current (Fan): 0.6 A running applications.
Power Method: Thermostat--Battery
Replacement Parts:
50007072-001 Replacement Battery Holder for FocusPRO® TH5220,
TH5320, TH6110, TH6220, and TH6320 Thermostat

Switch Positions
Terminal
Product Number System Fan Designations Stages Includes
YTH5320R1008 HEAT-OFF- AUTO-ON C, R, Rc, Rh, W-O/B, Up to 3 Heat/2 Cool C7089R1013 Wireless Outdoor Sensor;
COOL- W2-Aux/E, Y, Y2, G, L, Heat Pump or TH5320R1002 Wireless FocusPRO® Non-
AUTO- RAS Up to 2 Heat/2 Cool Programmable Thermostat;
EM.HEAT Conventional THM5320R1000 Equipment Interface Module;
C7735A1000 Return Air Sensor
YTH6320R1009 HEAT-OFF- AUTO-ON C, R, Rc, Rh, W-O/B, Up to 3 Heat/2 Cool TH6320R1004 Wireless FocusPRO® 5-1-1
COOL- W2-Aux/E, Y, Y2, G, L, Heat Pump or Programmable Thermostat;
AUTO- RAS Up to 2 Heat/2 Cool C7089R1013 Wireless Outdoor Sensor;
EM.HEAT Conventional THM5320R1000 Equipment Interface Module;
C7735A1000 Return Air Sensor

28 customer.honeywell.com 70-6910
RedLINK™ Wireless Products

Home Controls
Wireless Thermostat Kits
Everything you need to relocate thermostat or upgrade equipment
without running new wires
• WIRELESS FocusPRO® THERMOSTAT: Same great features of the
FocusPRO® thermostat - now wireless. Installs in minutes. Can
display outdoor temperature and humidity. 1 year battery life. 2
month low battery warning. Dual Fuel enabled -requires
C7089R1013 wireless outdoor sensor (sold separately).

Indoor Air Quality


• EQUIPMENT INTERFACE MODULE (EIM): All HVAC equipment is
wired to the module. Module receives communication from the
wireless devices.
• RETURN AIR SENSOR: Works with the Equipment Interface
Module to maintain safe indoor temperatures if power is lost at the
wireless thermostat. Maintains 62 F for heating and 82 F for cooling.
• RedLINK™ WIRELESS TECHNOLOGY: Powered by RedLINK™
reliability. No interference with other wireless devices in the home.

Combustion Controls
Residential
Hydronic Controls
Application: Gas, oil, electric, heat pump, forced warm air, hot water, Accessories:
steam or gravity 50002883-001 FocusPRO® 5000/6000 and PRO 3000/4000 Cover
Electrical Ratings: Plate Assembly
Equipment Interface Module--18 to 30 Vac, 50 Hz; 60 Hz 50007298-001 12 pack of medium coverplates (5 in. x 6 7/8 in.)
Changeover: Auto/Manual Selectable C7089R1013 Senses outdoor temperature and humidity to display on
Current (Cooling): 1.0 A running RedLINK™ enabled thermostats and accessories.
Current (Heating): 1.0 A running REM5000R1001 Use the Portable Comfort Control anywhere in the
Current (Fan): 0.6 A running home to experience a new level of comfort and convenience.

Controls
Power Method: Thermostat--Battery

Water
RedLINK™ Enabled. Works in both zoned and non-zoned
applications.
Replacement Parts:
50007072-001 Replacement Battery Holder for FocusPRO® TH5220,
TH5320, TH6110, TH6220, and TH6320 Thermostat

Building Automation
Switch Positions
Product Number System Fan Terminal Designations Stages Includes
YTH5320R1000 HEAT-OFF- AUTO-ON C, R, Rc, Rh, W-O/B, W2-Aux/E, Up to 3 Heat/2 Cool TH5320R1002 Wireless FocusPRO® Non-
COOL-AUTO- Y, Y2, G, L, RAS Heat Pump; Programmable Thermostat;
EM.HEAT Up to 2 Heat/2 Cool THM5320R1000 Equipment Interface Module;
Conventional C7735A1000 Return Air Sensor
YTH6320R1001 HEAT-OFF- AUTO-ON C, R, Rc, Rh, W-O/B, W2-Aux/E, Up to 3 Heat/2 Cool TH6320R1004 Wireless FocusPRO® 5-1-1
COOL-AUTO- Y, Y2, G, L, RAS Heat Pump; Programmable Thermostat;
EM.HEAT Up to 2 Heat/2 Cool THM5320R1000 Equipment Interface Module;
Conventional C7735A1000 Return Air Sensor

Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 29
RedLINK™ Wireless Products
Wireless Zoning Adapter Kits
Wireless Zoning Adapter Kit allows you to easily add to a
TrueZONE™ system without running new wires.
• WIRELESS ADAPTER: Allows for wireless zoning when used with
HZ432 or HZ322 TrueZONE™ panels (sold separately). Adapter
receives communication from the wireless devices.
• WIRELESS FocusPRO® THERMOSTAT: Same great features of the
FocusPRO® thermostat - now wireless. Installs in minutes. Displays
outdoor temperature and humidity (outdoor sensor sold separately).
1 year battery life. 2 month low battery warning.
• RedLINK™ WIRELESS TECHNOLOGY: Powered by RedLINK™
reliability. No interference with other wireless devices in the home.

Application: Heat Pump Systems; Forced warm air Accessories:


Changeover: Auto/Manual Selectable 50002883-001 FocusPRO® 5000/6000 and PRO 3000/4000 Cover
Power Method: Thermostat--Battery Plate Assembly
50007298-001 12 pack of medium coverplates (5 in. x 6 7/8 in.)
C7089R1013 Senses outdoor temperature and humidity to display on
RedLINK™ enabled thermostats and accessories.
REM5000R1001 Use the Portable Comfort Control anywhere in the
home to experience a new level of comfort and convenience.
RedLINK™ Enabled. Works in both zoned and non-zoned
applications.
Replacement Parts:
50007072-001 Replacement Battery Holder for FocusPRO® TH5220,
TH5320, TH6110, TH6220, and TH6320 Thermostat

Switch Positions
Product Number System Fan Includes
YTH5320R1025 HEAT-OFF-COOL-AUTO-EM.HEAT AUTO-ON THM4000R1000 Wireless Adapter;
TH5320R1002 Wireless FocusPRO® Non-Programmable Thermostat
YTH6320R1023 HEAT-OFF-COOL-AUTO-EM.HEAT AUTO-ON THM4000R1000 Wireless Adapter;
TH6320R1004 Wireless FocusPRO® 5-1-1 Programmable Thermostat

30 customer.honeywell.com 70-6910
RedLINK™ Wireless Products

Home Controls
Wireless FocusPRO® Thermostats
Easily add a zone to a TrueZONE™ system without running new
wires. Choose from programmable or non-programmable.
• Powered by RedLINK™ reliability
• No interference with other wireless devices in the home
• Works with compatible RedLINK™ enabled devices
• Same great features of the FocusPRO® thermostat now wireless
• Installs in minutes

Indoor Air Quality


• Can display outdoor temperature and humidity
• 1 year battery life
• 2 month low battery warning
• Dual Fuel enabled - requires THM5320R1000 Equipment Interface
Module and C7089R1013 Wireless Outdoor Sensor (sold
separately).

Combustion Controls
Residential
Application: Gas, oil, electric, heat pump, forced warm air, hot water, Accessories:
steam or gravity 50002883-001 FocusPRO® 5000/6000 and PRO 3000/4000 Cover
Dimensions, Approximate: 3 9/16 in. high x 5 13/16 in. wide x Plate Assembly
1 1/2 in. deep (91 mm high x 147 mm wide x 38 mm deep)

Hydronic Controls
50007298-001 12 pack of medium coverplates (5 in. x 6 7/8 in.)
Changeover: Auto/Manual Selectable C7089R1013 Senses outdoor temperature and humidity to display on
Operating Humidity Range (% RH): 5 to 90% RH, non-condensing RedLINK™ enabled thermostats and accessories.
Setting Temperature Range: C7735A1000 Mount on return duct for backup control of non-zoned
Heat: 40 F to 90 F; Cool: 50 F to 99 F RedLINK™ enabled wireless systems. Works with the EIM to maintain
(Heat: 4.5 C to 32 C; Cool: 10 C to 37 C) safe indoor temperatures if power is lost at the wireless thermostat.
Differential Temperature: ± 1 F (±0.5 C) REM5000R1001 Use the Portable Comfort Control anywhere in the
Power Method: Battery home to experience a new level of comfort and convenience.
Sensor Element: Thermistor RedLINK™ Enabled. Works in both zoned and non-zoned
Color: Premier White® applications.
Mounting: Horizontal
Comments: Thermostat is also available in kits for zoned and non- Replacement Parts:

Controls
Water
zoned systems 50007072-001 Replacement Battery Holder for FocusPRO® TH5220,
TH5320, TH6110, TH6220, and TH6320 Thermostat

Switch Positions Parts Needed for Operation Parts Needed for Operation
(not included) - Non-Zoned (not included) - TrueZONE™
Product Number System Fan Stages System System

Building Automation
TH5320R1002 HEAT-OFF- AUTO-ON Up to 3 Heat/2 Cool Heat Pump; THM5320R1000 Equipment HZ432 or HZ322 TrueZONE™
COOL-AUTO- Up to 2 Heat/2 Cool Conventional Interface Module panel; THM4000R1000 Wireless
EM.HEAT Adapter
TH6320R1004 HEAT-OFF- AUTO-ON Up to 3 Heat/2 Cool Heat Pump; THM5320R1000 Equipment HZ432 or HZ322 TrueZONE™
COOL-AUTO- Up to 2 Heat/2 Cool Conventional Interface Module panel; THM4000R1000 Wireless
EM.HEAT Adapter

Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 31
RedLINK™ Wireless Products
THM5320 Equipment Interface Module
• Powered by RedLINK™ reliability
• No interference with other wireless devices in the home
• Works with TH6320R1004 or TH5320R1002 Wireless FocusPRO®
thermostats
• Input for Return Air Sensor
• Quick-connect terminal blocks
• LEDs for power and system status

Easily relocate thermostat or upgrade equipment without running


new wires using this module and a wireless FocusPRO®
thermostat.
Application: Gas, oil, electric, heat pump, forced warm air, hot water, Accessories:
steam or gravity C7735A1000 Mount on return duct for backup control of non-zoned
Dimensions, Approximate: 8 1/8 in. high x 8 in. wide x 1 7/8 in. deep RedLINK™ enabled wireless systems. Works with the EIM to maintain
(206 mm high x 203 mm wide x 47 mm deep) safe indoor temperatures if power is lost at the wireless thermostat.
Electrical Ratings: 18 to 30 Vac, 50/60 Hz C7089R1013 Senses outdoor temperature and humidity to display on
Operating Humidity Range (% RH): 5 to 95% RH, non-condensing RedLINK™ enabled thermostats and accessories.
Current (Cooling): 1.0 A running REM5000R1001 Use the Portable Comfort Control anywhere in the
Current (Heating): 1.0 A running home to experience a new level of comfort and convenience.
Current (Fan): 0.6 A running RedLINK™ Enabled. Works in both zoned and non-zoned
Color: Gray applications.

Terminal Parts Needed for


Product Number Designations Stages Operation (not included) Description Comments
THM5320R1000 C, R, Rc, Rh, W-O/B, Up to 3 Heat/2 Cool TH6320R1004 or Controls up to 3 heat/2 cool heat pump Equipment Interface
W2-Aux/E, Y, Y2, G, Heat Pump or Up to TH5320R1002 Wireless systems or up to 2 heat/2 cool Module is also
L, RAS 2 Heat/2 Cool FocusPRO® Thermostat conventional systems when used with available in kits
Conventional the wireless FocusPRO® thermostat.

Wireless Adapter
Wireless Adapter allows you to easily add RedLINK™-enabled
thermostats to a TrueZONE™ system without running new wires.
Use a RedLINK™-enabled TrueSTEAM® Humidification System
with a Wireless Adapter to communicate and control humidity from
Prestige without running new wires to the living space. Prestige
also controls whole-house dehumidifiers like the Honeywell
TrueDRY®.
• Powered by RedLINK™ reliability.
• No interference with other wireless devices in the home.
• Communicates with Wireless Outdoor Sensor to automatically
control humidity to proper levels.

Dimensions, Approximate: 5 9/16 in. high x 4 3/8 in. wide x 1 1/4 in. Color: Gray
deep (141 mm high x 112 mm wide x 32 mm deep) Mounting: Mount Wireless Adapter on wall near HVAC equipment or on
Operating Humidity Range (% RH): 5 to 95% RH, non-condensing the duct.

Product Number Terminal Designations Requirements Description


THM4000R1000 A, B, C, D One adapter per zone control panel, Wireless Adapter allows you to easily add RedLINK™ enabled
HZ322 or HZ432 TrueZONE panel thermostats to a TrueZONE™ system without running new wires.

32 customer.honeywell.com 70-6910
RedLINK™ Accessories

Home Controls
REM5000 Portable Comfort Control
• No interference with other wireless devices in the home
• Works with compatible RedLINK™ enabled thermostats and
accessories
• Installs in minutes
• Touchscreen interface with backlit display
• Can display outdoor temperature and humidity
• Built-in pager with an audible noise helps locate the device in the

Indoor Air Quality


home
• Screen-lock feature helps prevent accidental changes
• 1 year battery life
• 2 month low battery warning
• In Non-Zoned Applications:
— Bring it with you anywhere in the home to sense and control tem-
perature from the room that you are in.
• In Zoned Applications:
— View and adjust all RedLINK™ enabled thermostats from a sin-

Combustion Controls
gle control.
• Controls up to 16 thermostats

Residential
Use the Portable Comfort Control anywhere in the home to
experience a new level of comfort and convenience. Works in both
zoned and non-zoned applications.
• Powered by RedLINK™ reliability

Hydronic Controls
Application: Zoned and Non-Zoned Applications Operating Temperature Range: 32 F to 120 F (0 C to 48.9 C)
Dimensions, Approximate: 6 1/4 in. high x 3 1/8 in. wide x 1 5/8 in. Differential Temperature: ± 1 F (±0.5 C)
deep (159 mm high x 79 mm wide x 41 mm deep) Power Method: Battery
Changeover: Auto or Manual Sensor Element: Thermistor
Operating Humidity Range (% RH): 5 to 90% RH, non-condensing

Product Number Comments Used With


REM5000R1001 Portable Comfort Control is also available in kits. RedLINK™ enabled thermostats and accessories

Controls
Water
C7089 Wireless Outdoor Sensor
Senses outdoor temperature and humidity to display on
RedLINK™ enabled thermostats and accessories.
• Powered by RedLINK™ reliability
• No interference with other wireless devices in the home
• Reliable performance in all climates

Building Automation
• Installs in minutes
• Up to 5 year battery life
• 2 month low battery warning
• Battery warning displayed on RedLINK™ enabled thermostats
• Includes 2 AA Lithium batteries and mounting hardware

Application: Outdoor Sensor


Dimensions, Approximate: (with mounting bracket) 5 in. high x
3 1/2 in. wide x 1 11/16 in. deep ((with mounting bracket) 127 mm high
x 89 mm wide x 43 mm deep)
Color: Gray

Components
Commercial
Operating Humidity Range (% RH): 0 to 100% RH, condensing
Operating Temperature Range: -40 F to 140 F (-40 C to 60 C)
Power Method: Battery
Sensor Element: Thermistor
Mounting: Mounts on a vertical wall with supplied bracket and
mounting hardware
Pneumatic Controls

Product Number Comments Used With


C7089R1013 Wireless Outdoor Sensor is also available in kits RedLINK™ enabled thermostats and accessories
Industrial Combustion
Controls

70-6910 33
RedLINK™ Accessories
C7735 Return Air Sensor
Mount on return duct for backup control of non-zoned RedLINK™
enabled Wireless Systems and Thermostats.
• Works with THM5320R1000 Equipment Interface Module to
maintain safe indoor temperatures if power is lost at the wireless
thermostat
• Takes control of the equipment by turning on the blower fan and
sensing the indoor temperature of the home
• Controls heating at 62 F and cooling at 82 F
• Provides homeowners with peace of mind
• Installs in minutes
• Includes mounting hardware

Dimensions, Approximate: 3 7/8 in. high x 4 1/8 in. wide x 1 1/4 in. Color: Gray
deep (77 mm high x 102 mm wide x 25 mm deep. Operating Temperature Range: 0 F to 200 F (-17.8 C to 93.3 C)
Sensor probe is 3 3/4 in. long (77 mm)) Mounting: Mounts on return duct

Product Number Application Comments Used With


C7735A1000 Mount on return duct for backup Return Air Sensor is also available in kits for THM5320R1000 Equipment Interface Module;
control of non-zoned systems non-zoned systems TH6320R1004 or TH5320R1002 Wireless
FocusPRO® Thermostat

34 customer.honeywell.com 70-6910
Communicating Thermostats

Home Controls
VisionPRO® IAQ Total Home Comfort System
The VisionPRO IAQ touchscreen universal programmable
thermostat provides electronic control of 24 Vac heating and
cooling systems in addition to humidification, dehumidification
and ventilation all with just 3 wires to the thermostat.
• Advanced dual-fuel control.
• Three wires to the living space allows for easy equipment upgrade
without having to run additional thermostat wire.

Indoor Air Quality


• Thermostat connects with Equipment Interface Module or
EnviraZONE panel to control temperature, humidification,
dehumidification and ventilation from a single point in the home.
• Automatically raises humidity levels throughout all rooms in the
home, moisturizing air to prevent symptoms of dryness and to
protect hardwood flooring and woodwork.
• Removes air pollutants by exchanging the stale air in a house with
fresh, filtered air better than having an open window.

Combustion Controls
Residential
Thermostat Dimensions, Approximate: 4 9/16 in. high x 6 in. wide x Dehumidification Setting Range: 40 to 80% RH.
1 1/4 in. deep (116 mm high x 152 mm wide x 32 mm deep) Humidification Setting Range: 10 to 60% RH.
Color: Premier White® Sensor Element: Thermistor
Programmability: 7 Day Multiple Day Programming or Non- Mounting: Horizontal
Programmable Switch Type: Yes, optional
Changeover: Auto/Manual Selectable Outdoor Sensor: Yes, optional

Hydronic Controls
Thermostat Display Size: 10 sq. in. Remote Sensor: Yes, optional
Electrical Ratings: THM5421 is rated 20 to 30 Vac
Accessories:
Operating Humidity Range (% RH): 5 to 90% RH, non-condensing
32003796-001 Premier White® cover plate 7 7/8 in. (200 mm) x 5 1/2 in.
Differential Temperature: ± 1 F (±0.5 C)
(140 mm)
Stages: Up to 3 Heat/2 Cool Conventional; Up to 4 Heat/2 Cool Heat
C7089U1006 Remote Outdoor Sensor
Pump
C7189U1005 Remote Indoor Sensor
Power Method: Communicating
Voltage: 20 to 30 Vac

Setting
Temperature

Controls
Switch Positions Range

Water
Product Terminal
Number Application Mounting System Fan Designations (F) (C) Comments Used With Includes
TH9421C1004 Conventional Horizontal HEAT- AUTO- 1, 2, 3 Heat: 40 F Heat: 4.5 C Includes Humidification Control THM5421C1008 Thermostat
and Heat OFF- ON- to 90 F; to 32 C; with or without Frost Protection, Equipment only
Pump COOL- CIRC Cool 60 F Cool: 15 C Dehumidification using Whole Interface Module
systems AUTO- to 99F to 37C House Dehumidifier or Air
EM.HEAT Conditioning with High or Low

Building Automation
speed fan, Advanced Patented
Ventilation Control and
Advanced Dual Fuel Heat
Pump Control.
THM5421C1008 Heat/Cool or Vertical — — 1, 2, 3, C, R, Rc, — — Includes Humidification Control TH9421 Equipment
Heat Pump Rh, R, W1-O/B, with or without Frost Protection, VisionPRO IAQ Interface
with Auxiliary W2-Aux, Dehumidification using Whole Thermostat Module Only
Heat W3-Aux2, Y, Y2, House Dehumidifier or Air
G, L, Out1, Out2, Conditioning with High or Low
In1, In2, Dats1, speed fan, Advanced Patented
Dats2, Hum1, Ventilation Control and

Components
Commercial
Hum2, Dhm1, Advanced Dual Fuel Heat
Dhm2, Vnt1, Pump Control.
Vnt2
YTH9421C1002 Heat/Cool or Horizontal HEAT- AUTO- 1, 2, 3, C, R, Rc, Heat: 40 F Heat: 4.5 C Includes Humidification Control — TH9421C1004
Heat Pump OFF- ON- Rh, R, W1-O/B, to 90 F; to 32 C; with or without Frost Protection, Thermostat
with Auxiliary COOL- CIRC W2-Aux, Cool: 60 F Cool: 15 C Dehumidification using Whole and
Heat AUTO- W3-Aux2, Y, Y2, to 99 F to 37 C House Dehumidifier or Air THM5421C10
EM.HEAT G, L, Out1, Out2, Conditioning with High or Low 08 Equipment
Pneumatic Controls

In1, In2, Dats1, speed fan, Advanced Patented Interface


Dats2, Hum1, Ventilation Control and Module
Hum2, Dhm1, Advanced Dual Fuel Heat
Dhm2, Vnt1, Pump Control.
Vnt2
YTH9421C1010 Heat/Cool or Horizontal HEAT- AUTO- 1, 2, 3, C, R, Rc, Heat: 40 F Heat: 4.5 C Includes Humidification Control — TH9421C1004
Heat Pump OFF- ON- Rh, R, W1-O/B, to 90 F; to 32 C; with or without Frost Protection, Thermostat,
with Auxiliary COOL- CIRC W2-Aux, Cool: 60 F Cool: 15 C Dehumidification using Whole THM5421C10
Heat AUTO- W3-Aux2, Y, Y2, to 99 F to 37 C House Dehumidifier or Air 08 Equipment
EM.HEAT G, L, Out1, Out2, Conditioning with High or Low Interface
Industrial Combustion

In1, In2, Dats1, speed fan, Advanced Patented Module and


Dats2, Hum1, Ventilation Control and C7089U1006
Controls

Hum2, Dhm1, Advanced Dual Fuel Heat Outdoor


Dhm2, Vnt1, Pump Control. Temperature
Vnt2 Sensor

70-6910 35
Communicating Thermostats
FocusPRO® Communicating Thermostats
The FocusPRO® non-programmable digital thermostat provides
control when connected to an EnviraZone Zone Panel or an
EnviraCOM equipment interface model or an EnviraCOM control
board at the equipment.
• Non-programmable digital thermostat.
• Large, clear, backlit display - easy to read in various lighting
conditions.
• Precise comfort control (± 1 F) - maintains consistent comfort to the
highest level of accuracy.
• Up to 3 Heat/2 Cool Heat Pump or Up to 2 Heat/2 Cool
Conventional.

Application: Conventional and Heat Pump systems; Network Zoning Frequency: 50 Hz; 60 Hz
3H/2C system Power Method: Communicating
Dimensions, Approximate: 3 7/16 in. high x 4 1/2 in. wide x 1 5/16 in. Sensor Element: Thermistor
deep (86 mm high x 114 mm wide x 33 mm deep) Color: Premier White®
Display Size: 5.09 sq. in Mounting: Horizontal
Changeover: Auto/Manual Selectable
Operating Humidity Range (% RH): 5 to 90% RH, non-condensing Replacement Parts:
Accuracy: ±1 F (±0.5 C) 50001137-001 FocusPRO® TH5110 Cover Plate Assembly
Switch Type: Relay

Switch Positions Setting Temperature Range


Terminal
Product Number System Fan Designations Stages (F) (C) Used With Zones
TH5320C1002 HEAT-OFF- AUTO-ON 1, 2, 3 Up to 3 Heat: 40 F to 90 F; Heat: 4.5 C to 32 C; W8835A EnviraZONE Up to 9
COOL-AUTO- Heat/2 Cool Cool: 50 F to 99 F Cool: 10 C to 37 C Panel;
EM.HEAT THM5421C1008
Equipment Interface
Module

36 customer.honeywell.com 70-6910
Telephone Access Module

Home Controls
W8735 Telephone Access Module
• Supports up to four independent EnviraCOM channels for a
maximum of 36 zones per W8735D (9 zones per channel when
using zone panels)
• Use with the TH9421C1004 VisionPRO IAQ Total Home Comfort
System and W8835A EnviraZone for zoned systems
• Use with THM5421C1008 for single zone applications
• Use with TH5320C1002 FocusPRO® EnviraCOM thermostat for

Indoor Air Quality


zoning applications
• Compatible with the T8635L Microelectronic Communicating
Programmable Thermostat, W8835A EnviraZone panel, or W8635A
and W8635B Equipment Interface Modules
• Use with any EnviraCOM generating products like R7184U Oil
Primary and L7224U Aquastat™ controls
• Provides remote telephone access to check or change thermostat
settings (i.e. heat, cool, auto, or off)
• Provides remote telephone access to check current indoor and

Combustion Controls
outdoor temperatures and indoor humidity
• Reports alert messages on high or low indoor/outdoor temperature,

Residential
The W8735D Telephone Access Module (TAM) provides remote high or low humidity, low battery, auxiliary input sensor tripped, pass
telephone access to the HVAC system when used with an code change, air filter change required, system alerts, and power
EnviraCOM™ enabled thermostat such as the TH9421C1004 outage
VisionPRO® IAQ Total Home Comfort System and the • Prioritize alerts to specify the time of day that the TAM will dial-out
TH5320C1002 FocusPRO® thermostat. These thermostats are used • Emergency drop call feature
with one or more of the following controls: A W8835A EnviraZone • Up to three telephone numbers can be programmed for alert
panel, a THM5421C1008 or W8703 Damper Interface Module. The messaging
W8735D also communicates with R7184P and R7184U oil primary • Auxiliary sensor input for use with an optional N.C. sensor contact
controls and L7224U Aquastat® remote temperature sensors as

Hydronic Controls
• Auxiliary output for local alert enunciation
well as any other EnviraCOM enabled controls to communicate
current status and alert information.
Dimensions, Approximate: 10 in. high x 5 in. wide x 2 in. deep Approvals:
(254 mm high x 127 mm wide x 51 mm deep) Federal Communications Commission: FCC rules: Part 68 and Part
Programmability: Up to 3 dialup numbers, alert prioritization, low/high 15
temperature alert settings, low/high humidity alert settings, and zone
naming.
Accessories:
50022037-001 Outdoor Sensor Interface Module
Operating Humidity Range (% RH): 5 to 95% RH, non-condensing
C7089U1006 Remote Outdoor Sensor
Ambient Temperature Range: 32 F to 120 F (0 C to 49 C)
TH9421C1004 VisionPRO® IAQ Total Home Comfort System with
Electrical Ratings: EnviraCOM™ Terminals: 1/D, 2/R, 3/B = 24 Vac;

Controls
Temperature, Humidification, Dehumidification and Ventilation Control

Water
Auxiliary Terminals: Aux In = N.C.24 Vac/24 Vdc, polarity insensitive;
THM5421C1008 Premier White VisionPRO IAQ Total Home Comfort
Aux Out = N.O. dry contact, 24 Vac/24 Vdc
Solution Equipment Interface Module with up to 4 Heat/2 Cool stages
LEDs: Communication and Battery LEDs
and 1, 2, 3, C, R, Rc, Rh, R, W1-O/B, W2-Aux, W3-Aux2, Y, Y2, G, L,
Network Zoning: Yes
Out1, Out2, In1, In2, Dats1, Dats2, Hum1, Hum2, Dhm1, Dhm2, Vnt1, V
Mounting: Number 6 screw and wall anchors supplied in bag assembly
W8703A1003 Damper Interface Module utilizes the Enviracom HVAC
Power Method: Plug in transformer, 12 Vdc (± 5%), 2.0 A, 9 Vdc
communication Network Use with T8635L and W8635A,B
battery backup

Building Automation
W8835A1004 EnviraZone Control Panel

Product Number Color Terminal Designations Number of Zones


W8735D1009 Premier White® 1/D, 2/R, 3/B (terminal connections per channel), Aux In, Aux Out 9 zones per channel; 2 channels; 18 total zones
W8735D1017 Premier White® 1/D, 2/R, 3/B (terminal connections per channel), Aux In, Aux Out 9 zones per channel; 4 channels; 36 total zones

Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 37
Thermostats Parts and Accessories
Parts and Accessories
Product Number Color Description Used With
32003796-001 Premier Premier White® cover plate 7 7/8 in. (200 mm) x TH8000 VisionPRO™ Series
White® 5 1/2 in. (140 mm) Thermostats

50000066-001 — Decorative Cover Plate for T87K, T87N and T8775 T87K, T87N, T8775
50000951-001 Premier Replacement Battery Holder for FocusPRO® TH5110 FocusPRO® TH5110
White® Thermostat Thermostat
50001137-001 Premier Coverplate assembly for use with FocusPRO® FocusPRO® TH5110
White® TH5110 thermostat. Includes one small and one Thermostat
medium coverplate, bracket for j-boxes and mounting
hardware. Small coverplate is 4 5/16 in. x 5 ¾ in.
Medium coverplate is 5 in. x 6 7/8 in.

50002883-001 Premier Coverplate assembly for use with FocusPRO® 6000/ FocusPRO® 6000, 5000;
White® 5000 and PRO 4000/3000 thermostats. Includes one PRO 4000, 3000
medium and one large coverplate, bracket for j-boxes
and mounting hardware. Medium coverplate is 5 in. x
6 7/8 in. Large coverplate is 6 in. x 8 5/16 in.

50005625-001 Premier Premier White® Cover Plate Assembly includes 4 3/4 T812 and TS812 Thermostats
White® in. (120mm) x 4 3/4 in. (120mm) coverplate, bracket
for junction box mounting, mounting screws.

50007072-001 Premier Replacement Battery Holder for FocusPRO® TH5220, FocusPRO® TH5220,
White® TH5320, TH6110, TH6220, and TH6320 Thermostat TH5320, TH6110, TH6220,
and TH6320 Thermostat
50010944-001 — Range Stop Assembly for T87K, T87N, includes: range The Round® T87K and T87N
stops for degree F and C with screws Mercury Free Thermostats
50022893-001 Premier White Coverplate 5 3/4 in. (146 mm) x 7 3/8 in. PRO TH1000 and TH2000
White® (187mm) Series Thermostats

50028399-001 Arctic Cover plate for Prestige Thermostats 7 7/8 in. (200 THX9000 Series Thermostats
White mm) x 5 1/2 in. (140 mm) Premier White® cover plate
7 7/8 in. (200 mm) x 5 1/2 in. (140 mm)
THP1000A1007 Gray Battery demo pack used with Prestige thermostat. THX9000 Series Thermostats
Powered by 6 AA batteries. Batteries sold separately.
THP9045A1007 Gray Wiring module that connects to "K" terminal on THX9000 Series Thermostats
thermostat and separates into Y and G signals to
equipment. Can be used in conventional and heat
pump systems requiring one wire more than is
available.

38 customer.honeywell.com 70-6910
Thermostat Guards

Home Controls
TG510 Versaguard Universal Thermostat Guards
Enclose and protect wall thermostats against tampering, damage
and unauthorized adjustment of thermostat settings.
• Unique double-wall construction provides extra measure of tamper-
resistance.
• Used in both new and existing applications.
• Tamper-resistant lock; key cannot be removed unless in locked
position.

Indoor Air Quality


• All models mount vertically or horizontally on wall or exposed
junction box.
• Vents in guard base allow airflow for optimum thermostat
performance.

Inside Height: 4 7/16 in. (113 mm) Size: small

Combustion Controls
Inside Width: 4 7/16 in. (113 mm) Wallplate Color: Opaque Polystyrene

Residential
Outside Height: 2 1/2 in. (64 mm)
Outside Width: 5 7/8 in. (149 mm) Accessories:
Outside Depth: 2 1/2 in. (64 mm) 191990A Replacement Keys (set of 2) for TG509, TG510, TG511 and
TG512

Product Number Color Ring Base Color Description Used With


* TG510A1001 Clear Acrylic clear acrylic Small universal thermostat guard Clear cover, clear base opaque T87 and others of
wallplate Fits T87 RS TX400 similar size

Hydronic Controls
TG510D1005 Painted metal opaque polystyrene Small Universal Thermostat Guard with Beige painted steel cover, T87 and others of
opaque ring base and wallplate similar size
* TRADELINE models • SUPER TRADELINE models

TG511 Versaguard Universal Thermostat Guards


Enclose and protect wall thermostats against tampering, damage
and unauthorized adjustment of thermostat settings.
• Unique double-wall construction provides extra measure of tamper-
resistance.

Controls
Water
• Used in both new and existing applications.
• Tamper-resistant lock; key cannot be removed unless in locked
position.
• All models mount vertically or horizontally on wall or exposed
junction box.
• Vents in guard base allow airflow for optimum thermostat
performance.

Building Automation
Inside Height: 5 1/16 in. (129 mm) Size: Medium
Inside Width: 6 1/16 in. (154 mm) Wallplate Color: Opaque Polystyrene
Outside Height: 2 15/16 in. (75 mm)
Outside Width: 7 1/2 in. (191 mm) Accessories:
Outside Depth: 2 15/16 in. (75 mm) 191990A Replacement Keys (set of 2) for TG509, TG510, TG511 and
TG512

Components
Commercial
Ring Base
Product Number Color Color Description Used With
* TG511A1000 Clear Acrylic clear acrylic Medium Universal Thermostat Guard with clear cover and TH3000 Series, TH4000 Series, TH5000
base, and opaque wallplate Fits T822, T834, T8034, Series, TH6000 Series, TH8000 Series,
T841, T874 with Q674, WR1F46, and others Others thermostats of similar size
TG511D1004 Painted metal opaque Medium Universal Thermostat Guard with Beige painted TH3000 Series, TH4000 Series, TH5000
polystyrene steel cover, opaque ring base and wallplate Fits T822, Series, TH6000 Series, TH8000 Series,
Pneumatic Controls

T834, T8034, T841, T874 with Q674, and others Others thermostats of similar size
* TRADELINE models • SUPER TRADELINE models
Industrial Combustion
Controls

70-6910 39
Thermostat Guards
TG512 Versaguard Universal Thermostat Guards
Enclose and protect wall thermostats against tampering, damage
and unauthorized adjustment of thermostat settings.
• Unique double-wall construction provides extra measure of tamper-
resistance.
• Used in both new and existing applications.
• Tamper-resistant lock; key cannot be removed unless in locked
position.
• All models mount vertically or horizontally on wall or exposed
junction box.
• Vents in guard base allow airflow for optimum thermostat
performance.

Inside Height: 5 7/8 in. (149 mm) Size: large


Inside Width: 8 3/8 in. (213 mm) Wallplate Color: Opaque Polystyrene
Outside Height: 3 3/8 in. (86 mm)
Outside Width: 9 3/4 in. (248 mm) Accessories:
Outside Depth: 3 3/8 in. (86 mm) 191990A Replacement Keys (set of 2) for TG509, TG510, TG511 and
TG512

Ring Base
Product Number Color Color Description Used With
* TG512A1009 Clear clear plastic Large Universal Thermostat Guard with clear cover and base, TH5000 Series, TH6000 Series, TH8000
Acrylic and opaque wallplate Fits T8082, T8085, T8600, and most Series, Other thermostats of similar size
electronic thermostats
TG512D1003 Painted opaque Large Universal Thermostat Guard with Beige painted steel TH5000 Series, TH6000 Series, TH8000
metal polystyrene cover, opaque ring base and wallplate Fits T8082, T8085, Series, Other thermostats of similar size
T8600, and most electronic thermostats
* TRADELINE models • SUPER TRADELINE models

40 customer.honeywell.com 70-6910
TrueZONE™ Zoning Panels and Kits

Home Controls
TrueZONE® HZ432 Panel
TrueZONE® HZ432 Panel for conventional, heat pump or dual fuel
applications expandable up to 32 zones (3H/2C)
• Intuitive Installer setup. Easy-to-follow, digital display uses real
language to guide installer through four easy steps.
• Standard Checkout Procedure
• Robust Push Terminals
• Common-Sense LEDs

Indoor Air Quality


• Clean, Professional Installation
• Variable-Speed Fan Control
• Discharge Air Temperature Staging
• Advanced Dual-Fuel Operation
• Use with TAZ-4 Add-A-Zone to expand to 32 zones
• RedLINK™ enabled for up to 4 wireless zones when used with
THM4000R1000 Wireless Adapter

Application: Zoning

Combustion Controls
Available for: 4 Zones
Auto Changeover: Yes

Residential
Discharge Air Temperature Compatible: Yes
Individual Zone Fan Control: Yes
Resettable Fuse: Yes
Voltage: 24V

Hydronic Controls
Number of Network Heat Pump Emergency
Product Number Stages Zones Zoning LEDs Compatible Heat Switch Includes
HZ432 3 Heat/ 4 Zone, No Yes Yes Yes —
2 Cool Expandable
HZ432K 3 Heat/ 4 Zone, No Yes Yes Yes HZ432 Zone Control Panel, AT140 Transformer, C7735A
2 Cool Expandable Discharge Air Temperature Sensor
YHZ432R1108 3 Heat/ 4 Zone No Yes Yes Yes Zone panel, two programmable wireless FocusPRO®
2 Cool thermostats, wireless adapter module, portable comfort

Controls
Water
control. Wireless outdoor air temperature sensor,
transformer, and discharge air temperature sensor
YHZ432R5108 3 Heat/ 4 Zone No Yes Yes Yes Zone panel, one Prestige HD and one programmable
2 Cool wireless FocusPRO® thermostat, wireless adapter
module, portable comfort control. Wireless outdoor air
temperature sensor, transformer, and discharge air
temperature sensor

Building Automation
TotalZONE® Add-A-Zone (TAZ) Panel
Zone panel used to add zones to HZ432.
• Used with HZ432 TrueZONE Panel to expand number of zones.
• Use multiple TAZ-4 Control Panels to control up to 32 zones.

Application: Zoning - add a zone panel (4-zone)


Auto Changeover: Yes
Compatible with Supply Air Sensor: No

Components
Commercial
Discharge Air Temperature Compatible: Yes
Individual Zone Fan Control: Yes
Resettable Fuse: Yes
Voltage: 24V

Pneumatic Controls

Product Number Stages Number of Zones Network Zoning LEDs Heat Pump Compatible Emergency Heat Switch
TAZ-4 3 Heat/2 Cool 4 Zone No Yes Yes No
Industrial Combustion
Controls

70-6910 41
TrueZONE™ Zoning Panels and Kits
TrueZONE® HZ322 Panel
TrueZONE® HZ322 Panel for conventional and heat pump
applications up to 3 zones (2H/2C).
• Intuitive Installer setup. Easy-to-follow, digital display uses real
language to guide installer through four easy steps.
• Standard Checkout Procedure
• Robust Push Terminals
• Common-Sense LEDs
• Clean, Professional Installation
• Smaller Footprint
• Variable-Speed Fan Control
• Discharge Air Temperature Staging
• RedLINK™ enabled for wireless operation when used with
THM4000R1000 wireless adapter

Application: Zoning
Available for: 3 Zones
Auto Changeover: Yes
Discharge Air Temperature Compatible: Yes
Individual Zone Fan Control: Yes
Resettable Fuse: Yes
Voltage: 24V

Number of Network Heat Pump Emergency


Product Number Stages Zones Zoning LEDs Compatible Heat Switch Includes
HZ322 2 Heat/2 3 Zone No Yes Yes Yes —
Cool
HZ322K 2 Heat/ 3 Zone No Yes Yes Yes HZ322 Zone Control Panel, AT140 Transformer, C7735A
2 Cool Discharge Air Temperature Sensor
YHZ322R1108 2 Heat/ 3 Zone No Yes Yes Yes Zone panel, two programmable wireless FocusPRO®
2 Cool thermostats, wireless adapter module, portable comfort
control. Wireless outdoor air temperature sensor,
transformer, and discharge air temperature sensor
YHZ322R5108 2 Heat/ 3 Zone No Yes Yes Yes Zone panel, one Prestige HD and one programmable
2 Cool wireless FocusPRO® thermostat, wireless adapter module,
portable comfort control. Wireless outdoor air temperature
sensor, transformer, and discharge air temperature sensor

42 customer.honeywell.com 70-6910
TrueZONE™ Zoning Panels and Kits

Home Controls
TrueZONE® HZ311 Panel
TrueZONE® HZ311 Panel for conventional, single stage
applications up to 3 zones (1H/1C).
• Robust Push Terminals
• Common-Sense LEDs
• Clean, Professional Installation
• Smaller Footprint
• Variable-Speed Fan Control

Indoor Air Quality


Application: Zoning
Available for: 3 Zones
Auto Changeover: Yes
Discharge Air Temperature Compatible: Yes
Individual Zone Fan Control: Yes
Resettable Fuse: Yes
Voltage: 24V

Combustion Controls
Heat Pump

Residential
Product Number Stages Number of Zones Network Zoning LEDs Compatible Includes
HZ311 1 Heat/1 Cool 3 Zone No Yes No —
HZ311K 1 Heat/1 Cool 3 Zone No Yes No HZ311 Zone Control Panel, AT140 Transformer,
C7735A Discharge Air Temperature Sensor

TrueZONE® HZ221 Panel

Hydronic Controls
TrueZONE® HZ221 Panel for single stage heat pumps with
auxiliary heat applications up to two zones.
• Robust Push Terminals
• Common-Sense LEDs
• Clean, Professional Installation
• Smaller Footprint
• Variable-Speed Fan Control

Application: Zoning
Available for: 2 Zones
Auto Changeover: Yes

Controls
Water
Discharge Air Temperature Compatible: Yes
Individual Zone Fan Control: Yes
Resettable Fuse: Yes
Voltage: 24V

Number Network Heat Pump Emergency


Product Number Stages of Zones Zoning LEDs Compatible Heat Switch Includes

Building Automation
HZ221 1 stage heat pump with 2 Zone No Yes Yes/Heat Pump Yes —
auxiliary heat Only
HZ221K 1 stage heat pump with 2 Zone No Yes Yes/Heat Pump Yes HZ221 Zone Control Panel, AT140
auxiliary heat Only Transformer, C7735A Discharge Air
Temperature Sensor

Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 43
EnviraZONE Panels and Kits
EnviraZONE Control Panel
Advanced zoning control system using the EnviraCOM™
communications protocol. The easiest to install networked zoning
system in the industry. Zone of Greatest Demand algorithm
reduces and regulates HVAC cycles, decreases damper cycles,
and increases efficiency.
• Use with VisionPRO IAQ Thermostats or FocusPRO®
communicating thermostats.
• Expandable to nine zones with additional W8703 Damper Interface
Modules and Thermostats.
• Compatible with conventional gas, oil, electric or heat pump systems
up to 3H/2C.
• Unsurpassed ease-of-wiring with only three wires to connect
between devices.
• True communicating system using standard thermostat wire.
• Networked zoning enables these features: Time synchronization,
Selectable high and low equipment protection settings, Adjustable
purge timing and damper positions.
• Telephone access when used with optional W8735D Telephone
Access Modules.
• Uses Zone of Greatest Demand Intelligence to reduce system
cycling.
• Optional use of two transformers for power when many dampers are
needed.
Networked zoning kits are one-box solutions that contain a W8835
Panel, VisionPRO or FocusPRO® Communicating Thermostats,
C7835 Discharge Air Temperature Sensor, AT140 Transformer,
C7089U Outdoor Temperature Sensor, and 50022037-001 Outdoor
Temperature Interface Module.

Application: Zoning
Auto Changeover: Yes
Compatible with Supply Air Sensor: No
Discharge Air Temperature Compatible: Yes
Individual Zone Fan Control: Yes
Resettable Fuse: Yes
Voltage: 24V

Emergency
Number of Network Heat Pump Heat
Product Number Stages Zones Zoning LEDs Compatible Switch Includes
W8835A1004 3 Heat/ 3 Zone Yes Yes Yes No —
2 Cool
Y8835A1028 3 Heat/ 3 zone kit with 3 Yes Yes Yes No W8835A Zone Control Panel, 3-VisionPRO IAQ
2 Cool VisionPRO IAQ Thermostats, AT140 Transformer, C7835 Discharge Air
thermostats Temperature Sensor, C7089U Outdoor Temperature
Sensor, and 50022037-001 Outdoor Temperature
Interface Module
Y8835A1036 3 Heat/ 2 zone kit with 1 Yes Yes Yes No W8835A Zone Control Panel, 1-VisionPRO IAQ
2 Cool VisionPRO Thermostat, 1-FocusPRO® Communicating Thermostat,
thermostat and 1 AT140 Transformer, C7835 Discharge Air Temperature
FocusPRO® Sensor, C7089U Outdoor Temperature Sensor, and
thermostat 50022037-001 Outdoor Temperature Interface Module
Y8835A1044 3 Heat/ 2 zone kit with 2 Yes Yes Yes No W8835A Zone Control Panel, 2-VisionPRO IAQ
2 Cool Vision PRO IAQ Thermostats, AT140 Transformer, C7835 Discharge Air
thermostats Temperature Sensor, C7089U Outdoor Temperature
Sensor, and 50022037-001 Outdoor Temperature
Interface Module
Y8835A1051 3 Heat/ 3 zone kit with 1 Yes Yes Yes No W8835A Zone Control Panel, 1-VisionPRO IAQ
2 Cool VisionPRO IAQ Thermostat, 2-FocusPRO® Communicating Thermostats,
and 2 AT140 Transformer, C7835 Discharge Air Temperature
FocusPRO® Sensor, C7089U Outdoor Temperature Sensor, and
communicating 50022037-001 Outdoor Temperature Interface Module
thermostats

44 customer.honeywell.com 70-6910
EnviraZONE Accessories

Home Controls
Outdoor Sensor Interface Module
Application: 50022037 is required when using the C7089U temperature sensor with the W8835 EnviraZONE Panel

Product Number Network Zoning


50022037-001 Yes

Indoor Air Quality


C7835 Discharge Air Temperature Sensor
Duct-mounted temperature probe used to provide capacity control
of heating and cooling equipment. Used with Honeywell Network
Zoning System and single unit zone applications.

LEDs: Yes
Network Zoning: Yes
Compatible with Discharge Air Temperature Sensor: Yes

Combustion Controls
Heat Pump Compatible: Yes

Residential
Product Number Application Used With
C7835A1009 Sensor Networked Zoning System

Hydronic Controls
W8703 Damper Interface Module
The W8703 Damper Interface Module expands the capacity of the
W8835 EnviraZONE control panel by three zones.
• Use with up to three thermostats and a W8835 EnviraZONE Control
Panel.
• Use one or two W8703 to expand W8835 to 6 or 9 zones.

Individual Zone Fan Control: Yes


LEDs: Yes
Network Zoning: Yes

Controls
Water
Product Number Application Number of Zones Used With
W8703A1003 Damper Interface Module Up to 3 zones when used with communicating thermostats and Networked Zoning System

Building Automation
EnviraCOM Zone Control Panel

W8735A EnviraCOM™ Serial Adapter


The EnviraCOM Serial Adapter allows a user to control Honeywell
EnviraCOM Communicating Thermostats, EnviraZONE Systems,
and other HVAC products by using any manufacturer's RS-232
compatible home automation control system.
• Use with YTH9421C VisionPRO IAQ thermostat, or with W8835

Components
Commercial
EnviraZONE zone control panel.
• Can be used with W8735D Telephone Access Module.
• Allows easy integration to host controllers, gateways and computers.
• Uses standard DB-9 connector.
• Powered through EnviraCOM bus; no external power source
required.
• Uses true RS-232 signals; universally compatible.
Pneumatic Controls

Product Number Application Used With


W8735A1005 The W8735A EnviraCOM Serial Adapter provides local access to an EnviraCOM HVAC system through a Networked Zoning System
host computer, gateway, or controller. The host provides the application to control the W8735A and the
Industrial Combustion

HVAC equipment.
Controls

70-6910 45
Zone Control Panel Accessories
Zone Control Panel Accessories
Product Number Description
FPC Freeze Protection Control - Breaks Y circuit to compressor below 36 F and remakes at 46 F

MSTN Power Open Power Close Damper Actuator

PIRR Plug-In replacement relay - Used with legacy zone control panels including MM-2, MM-3,
MABS-3, and MARK-V

SDCR Slave Damper Control Relay

SPC Static Pressure Control - Used with MARD for bypass control

46 customer.honeywell.com 70-6910
Zone Control Dampers

Home Controls
Automatic Round Damper (ARD)
Round damper with 24-volt, spring return damper motor used to
control volume of circulating air in heating, cooling, and ventilating
systems.
• Galvanized steel.
• Single-blade damper.
• Shipped as power closed/spring return open damper, for use with
Honeywell Zoning Systems.

Indoor Air Quality


• Can be field-converted to power open/spring return closed damper
when used as an independent zone or for fresh air intake.
• Blade closes off tightly against gasket for minimal leakage.
• Rated to operate up to 1 in. wc.
• Available in 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, and 20 in. diameter
sizes.

Application: Zone Damper


Voltage: 24V

Combustion Controls
Wires to Motor: 2
Motor Timing: 30 seconds power open/10 seconds spring return

Residential
Other Motor Information: Range stops

Product Number Size (inch) Shape Motor Mount Motor Type Description
ARD10 10 in. Round TopSide Power closed, spring open, reversible Spring Return Round Damper
ARD12 12 in. Round TopSide Power closed, spring open, reversible Spring Return Round Damper
ARD14 14 in. Round TopSide Power closed, spring open, reversible Spring Return Round Damper

Hydronic Controls
ARD16 16 in. Round TopSide Power closed, spring open, reversible Spring Return Round Damper
ARD18 18 in. Round TopSide Power closed, spring open, reversible Spring Return Round Damper
ARD20 20 in. Round TopSide Power closed, spring open, reversible Spring Return Round Damper
ARD5 5 in. Round TopSide Power closed, spring open, reversible Spring Return Round Damper
ARD6 6 in. Round TopSide Power closed, spring open, reversible Spring Return Round Damper
ARD7 7 in. Round TopSide Power closed, spring open, reversible Spring Return Round Damper
ARD8 8 in. Round TopSide Power closed, spring open, reversible Spring Return Round Damper

Controls
ARD9 9 in. Round TopSide Power closed, spring open, reversible Spring Return Round Damper

Water
EARD Fresh Air Damper
The EARD is a round damper with a 24 Vac powered-open/spring-
closed motor. It is used for fresh air intake for ventilation or for
combustion makeup air.

Building Automation
• Adjustable damper position range stops.
• Single-blade damper.
• Shipped as power open/spring return closed damper.
• Galvanized steel.
• Quiet operation.
• Can be field-converted to power closed/spring return open damper.
• Blade closes off tightly against gasket for minimal leakage.
• Male (crimped) and female (uncrimped) ends to connect to any rigid
or flexible round duct.

Application: Fresh Air Damper

Components
Commercial
Voltage: 24V
Wires to Motor: 2
Motor Timing: 30 seconds power closed/10 seconds spring return
Other Motor Information: Range stops

Product Number Size (inch) Shape Motor Mount Motor Type Description
EARD5 5 in. Round TopSide Power open, spring closed, reversible Spring Return Round Damper
Pneumatic Controls

EARD6 6 in. Round TopSide Power open, spring closed, reversible Spring Return Round Damper
EARD7 7 in. Round TopSide Power open, spring closed, reversible Spring Return Round Damper
EARD8 8 in. Round TopSide Power open, spring closed, reversible Spring Return Round Damper
Industrial Combustion
Controls

70-6910 47
Zone Control Dampers
Modulating Automatic Round Dampers (MARD)
The Modulating Automatic Round Damper is a round damper with
a 24-Vac, floating-control type modulating motor for bypass and
zone damper control.
• Uses 90-second open to closed motor.
• Can be used as a zone damper.
• ML6161 is replacement motor.
• Available in 5, 6, 7, 8, 9, 10, 12, 14, 16, and 18 in. diameter sizes.
• Used with Static Pressure Control (SPC) for bypass applications.

Application: Motorized Bypass or Zone Damper


Voltage: 24V
Wires to Motor: 3
Motor Timing: 90 seconds

Product Number Size (inch) Shape Motor Mount Motor Type Description
MARD10 10 in. Round TopSide Floating Power Open, Power Close Damper
MARD12 12 in. Round TopSide Floating Power Open, Power Close Damper
MARD14 14 in. Round TopSide Floating Power Open, Power Close Damper
MARD16 16 in. Round TopSide Floating Power Open, Power Close Damper
MARD18 18 in. Round TopSide Floating Power Open, Power Close Damper
MARD5 5 in. Round TopSide Floating Power Open, Power Close Damper
MARD6 6 in. Round TopSide Floating Power Open, Power Close Damper
MARD8 8 in. Round TopSide Floating Power Open, Power Close Damper
MARD9 9 in. Round TopSide Floating Power Open, Power Close Damper

Retrofit Round Damper (RRD)


The RRD is a round damper that is easily inserted into rigid round
ducts for retrofit zoning in forced air heating and cooling systems.
It is available in four sizes for use in 5 in., 6 in., 7 in., and 8 in.
ducts. The damper is used with Honeywell HZ221, HZ311, HZ322,
HZ432 and similar zone control systems. The power open, power
closed actuator draws 2 VA allowing multiple dampers per zone,
but delivers high torque for reliable operation.
• Easy slide-in installation
• 2 VA allows for many dampers on one zone
• Available in 4 sizes to fit most rigid round branch ducts
• Quiet, long life motor automatically shuts itself off in full open and
closed positions
• Gaskets around blade and under motor housing for low internal
leakage and very low external leakage
• Range stops with easy adjustment from top of motor
• Easy to see and reliable mechanical blade position indicator
• Easy to hook up with conventional thermostat wire
• Simple manual blade positioning with push button gear release

Application: Zone Damper


Voltage: 24V
Wires to Motor: 3
Motor Timing: 90 seconds
Other Motor Information: Range stops

Product Number Size (inch) Shape Motor Mount Motor Type Description
RRD5 5 in. Round Direct connection to damper shaft Power open/Power close Retrofit Round Damper
RRD6 6 in. Round Direct connection to damper shaft Power open/Power close Retrofit Round Damper
RRD7 7 in. Round Direct connection to damper shaft Power open/Power close Retrofit Round Damper
RRD8 8 in. Round Direct connection to damper shaft Power open/Power close Retrofit Round Damper

48 customer.honeywell.com 70-6910
Zone Control Dampers

Home Controls
Static Pressure Regulating Damper (SPRD)
Single-blade, steel barometric damper used to bypass excess air
when majority of zone dampers are closed.
• Counter-balanced weighted arm to control bypass air for zoned
systems.
• Available in rectangular/square and round sizes.
• Air pressure in duct system increases as zone dampers close,
pushing the SPRD open automatically.

Indoor Air Quality


• Arm and weight both adjustable to control amount of air bypassed.
• Recommended for low pressure systems with less than 0.5 in. wc.
• For larger systems and tighter pressure control, use MARD damper
and static pressure controller (SPC).
• Additional weights available
• Available in: Round sizes 7, 8, 9, 10, 12, 14 and 16 in. diameters.
Rectangular sizes (width x height)12 x 8, 12 x 10, 12 x 12, 20 x 8, 20
x 10, 20 x 12 in.

Combustion Controls
Residential
Product Number Size (inch) Shape Motor Type Used With
SPRD7 7 in. Round Weighted damper arm Honeywell zoning systems
SPRD8 8 in. Round Weighted damper arm Honeywell zoning systems
SPRD9 9 in. Round Weighted damper arm Honeywell zoning systems

Hydronic Controls
SPRD10 10 in. Round Weighted damper arm Honeywell zoning systems
SPRD12 12 in. Round Weighted damper arm Honeywell zoning systems
SPRD14 14 in. Round Weighted damper arm Honeywell zoning systems
SPRD16 16 in. Round Weighted damper arm Honeywell zoning systems
SPRD12X10 12 in. x 10 in. Rectangular Weighted damper arm Honeywell zoning systems
SPRD12X12 12 in. x 12 in. Rectangular Weighted damper arm Honeywell zoning systems
SPRD12X8 12 in. x 8 in. Rectangular Weighted damper arm Honeywell zoning systems
SPRD20X10 20 in. x 10 in. Rectangular Weighted damper arm Honeywell zoning systems

Controls
Water
SPRD20X12 20 in. x 12 in. Rectangular Weighted damper arm Honeywell zoning systems
SPRD20X8 20 in. x 8 in. Rectangular Weighted damper arm Honeywell zoning systems

SPRD Damper Replacement Parts

Building Automation
Product Number Description
32005688-001 SPRD Weight
32005981-003 SPRD Counterweight Assembly (includes, arm, coupling, and weight). Used with SPRD 6, 8,9 and SPRD12x8, 20x8, 12x10,
and 20x10
32005981-004 SPRD Counterweight Assembly (includes arm, coupling, and weight). Used with SPRD10, 12,14,16, and SPRD12x12 and
20x12

Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 49
Zone Control Dampers
ZD Series Dampers
The ZD is a power close and spring open damper. It has a 24-volt
motor used to control circulating air in heating, cooling and
ventilating systems. It is used when a normally-open damper is
required. The ZD is typically used with the TrueZONE systems and
other electronic zoning systems.
• Kevlar gearing reduces wear, more than doubling damper life.
• Adjustable range stops.
• Mechanical visual position indicator for damper status.
• Solid construction using extruded aluminum frame and blades.
• Parallel blade design for low leakage performance.
• Simple, easy-to-wire, two-wire installation.
• Reliable, strong, 24-volt spring-return motor.
• Fail-safe, normally open operation.
• Compatible with conventional and networked zoning.
• Ordering Instructions: Order ZD (dimension 1) x (dimension 2).
(Motor is always mounted on dimension 2 side.) For example,
ZD10x8 is a 10 in. x 8 in. damper with the motor on the 8 in. side; but
a ZD8x10 is a 8 in. x 10 in. damper that has the motor on the 10 in.
side.
• Damper can be installed in any orientation (mounting side can be on
either the bottom or the side of the duct).

Application: Parallel Blade Damper


Voltage: 24V
Wires to Motor: 2
Motor Timing: 30 seconds power open/10 seconds spring return
Other Motor Information: Range stops

Product Number Size (inch) Shape Motor Mount Motor Type Used With
ZD6X6 6 in. x 6 in. Square Side power closed, spring open Honeywell zoning systems
ZD6X8 6 in. x 8 in. Rectangular Bottom power closed, spring open Honeywell zoning systems
ZD6X10 6 in. x 10 in. Rectangular Bottom power closed, spring open Honeywell zoning systems
ZD6X12 6 in. x 12 in. Rectangular Bottom power closed, spring open Honeywell zoning systems
ZD6X14 6 in. x 14 in. Rectangular Bottom power closed, spring open Honeywell zoning systems
ZD6X16 6 in. x 14 in. Rectangular Bottom power closed, spring open Honeywell zoning systems
ZD6X18 6 in. x 18 in. Rectangular Bottom power closed, spring open Honeywell zoning systems
ZD6X20 6 in. x 20 in. Rectangular Bottom power closed, spring open Honeywell zoning systems
ZD6X22 6 in. x 22 in. Rectangular Bottom power closed, spring open Honeywell zoning systems
ZD6X24 6 in. x 24 in. Rectangular Bottom power closed, spring open Honeywell zoning systems
ZD6X28 6 in. x 28 in. Rectangular Bottom power closed, spring open Honeywell zoning systems
ZD8X6 8 in. x 6 in. Rectangular Side power closed, spring open Honeywell zoning systems
ZD8X8 8 in. x 8 in. Square Side power closed, spring open Honeywell zoning systems
ZD8X10 8 in. x 10 in. Rectangular Bottom power closed, spring open Honeywell zoning systems
ZD8X12 8 in. x 12 in. Rectangular Bottom power closed, spring open Honeywell zoning systems
ZD8X14 8 in. x 14 in. Rectangular Bottom power closed, spring open Honeywell zoning systems
ZD8X16 8 in. x 14 in. Rectangular Bottom power closed, spring open Honeywell zoning systems
ZD8X18 8 in. x 18 in. Rectangular Bottom power closed, spring open Honeywell zoning systems
ZD8X20 8 in. x 20 in. Rectangular Bottom power closed, spring open Honeywell zoning systems
ZD8X22 8 in. x 22 in. Rectangular Bottom power closed, spring open Honeywell zoning systems
ZD8X24 8 in. x 24 in. Rectangular Bottom power closed, spring open Honeywell zoning systems
ZD8X26 8 in. x 26 in. Rectangular Bottom power closed, spring open Honeywell zoning systems
ZD8X28 8 in. x 28 in. Rectangular Bottom power closed, spring open Honeywell zoning systems
ZD10X6 10 in. x 6 in. Rectangular Side power closed, spring open Honeywell zoning systems
ZD10X8 10 in. x 8 in. Rectangular Side power closed, spring open Honeywell zoning systems
ZD10X10 10 in. x 10 in. Square Side power closed, spring open Honeywell zoning systems
ZD10X12 10 in. x 12 in. Rectangular Bottom power closed, spring open Honeywell zoning systems
ZD10X14 10 in. x 14 in. Rectangular Bottom power closed, spring open Honeywell zoning systems
ZD10X16 10 in. x 16 in. Rectangular Bottom power closed, spring open Honeywell zoning systems
ZD10X18 10 in. x 18 in. Rectangular Bottom power closed, spring open Honeywell zoning systems
ZD10X20 10 in. x 20 in. Rectangular Bottom power closed, spring open Honeywell zoning systems
ZD10X22 10 in. x 22 in. Rectangular Bottom power closed, spring open Honeywell zoning systems
ZD10X24 10 in. x 24 in. Rectangular Bottom power closed, spring open Honeywell zoning systems

50 customer.honeywell.com 70-6910
Zone Control Dampers

Home Controls
Product Number Size (inch) Shape Motor Mount Motor Type Used With
ZD10X26 10 in. x 26 in. Rectangular Bottom power closed, spring open Honeywell zoning systems
ZD10X28 10 in. x 28 in. Rectangular Bottom power closed, spring open Honeywell zoning systems
ZD12X6 12 in. x 6 in. Rectangular Side power closed, spring open Honeywell zoning systems
ZD12X8 12 in. x 8 in. Rectangular Side power closed, spring open Honeywell zoning systems
ZD12X10 12 in. x 10 in. Rectangular Side power closed, spring open Honeywell zoning systems

Indoor Air Quality


ZD12X12 12 in. x 12 in. Square Side power closed, spring open Honeywell zoning systems
ZD12X14 12 in. x 14 in. Rectangular Bottom power closed, spring open Honeywell zoning systems
ZD12X16 12 in. x 16 in. Rectangular Bottom power closed, spring open Honeywell zoning systems
ZD12X18 12 in. x 18 in. Rectangular Bottom power closed, spring open Honeywell zoning systems
ZD12X20 12 in. x 20 in. Rectangular Bottom power closed, spring open Honeywell zoning systems
ZD12X22 12 in. x 22 in. Rectangular Bottom power closed, spring open Honeywell zoning systems

Combustion Controls
ZD12X24 12 in. x 24 in. Rectangular Bottom power closed, spring open Honeywell zoning systems

Residential
ZD12X26 12 in. x 26 in. Rectangular Bottom power closed, spring open Honeywell zoning systems
ZD12X28 12 in. x 28 in. Rectangular Bottom power closed, spring open Honeywell zoning systems
ZD14X6 14 in. x 6 in. Rectangular Side power closed, spring open Honeywell zoning systems
ZD14X8 14 in. x 8 in. Rectangular Side power closed, spring open Honeywell zoning systems
ZD14X10 14 in. x 10 in. Rectangular Side power closed, spring open Honeywell zoning systems
ZD14X12 14 in. x 12 in. Rectangular Side power closed, spring open Honeywell zoning systems

Hydronic Controls
ZD14X14 14 in. x 14 in. Square Side power closed, spring open Honeywell zoning systems
ZD14X16 14 in. x 16 in. Rectangular Bottom power closed, spring open Honeywell zoning systems
ZD14X18 14 in. x 18 in. Rectangular Bottom power closed, spring open Honeywell zoning systems
ZD14X20 14 in. x 20 in. Rectangular Bottom power closed, spring open Honeywell zoning systems
ZD14X22 14 in. x 22 in. Rectangular Bottom power closed, spring open Honeywell zoning systems
ZD14X24 14 in. x 24 in. Rectangular Bottom power closed, spring open Honeywell zoning systems
ZD14X26 14 in. x 26 in. Rectangular Bottom power closed, spring open Honeywell zoning systems
ZD14X28 14 in. x 28 in. Rectangular Bottom power closed, spring open Honeywell zoning systems

Controls
Water
ZD16X6 16 in. x 6 in. Rectangular Side power closed, spring open Honeywell zoning systems
ZD16X8 16 in. x 8 in. Rectangular Side power closed, spring open Honeywell zoning systems
ZD16X10 16 in. x 10 in. Rectangular Side power closed, spring open Honeywell zoning systems
ZD16X12 16 in. x 12 in. Rectangular Side power closed, spring open Honeywell zoning systems
ZD16X14 16 in. x 14 in. Rectangular Side power closed, spring open Honeywell zoning systems

Building Automation
ZD16X16 16 in. x 16 in. Square Side power closed, spring open Honeywell zoning systems
ZD16X18 16 in. x 18 in. Rectangular Bottom power closed, spring open Honeywell zoning systems
ZD16X20 16 in. x 20 in. Rectangular Bottom power closed, spring open Honeywell zoning systems
ZD16X22 16 in. x 22 in. Rectangular Bottom power closed, spring open Honeywell zoning systems
ZD16X24 16 in. x 24 in. Rectangular Bottom power closed, spring open Honeywell zoning systems
ZD16X26 16 in. x 26 in. Rectangular Bottom power closed, spring open Honeywell zoning systems
ZD18X6 18 in. x 6 in. Rectangular Side power closed, spring open Honeywell zoning systems

Components
ZD18X8 18 in. x 8 in. Rectangular Side power closed, spring open Honeywell zoning systems

Commercial
ZD18X10 18 in. x 10 in. Rectangular Side power closed, spring open Honeywell zoning systems
ZD18X12 18 in. x 12 in. Rectangular Side power closed, spring open Honeywell zoning systems
ZD18X14 18 in. x 14 in. Rectangular Side power closed, spring open Honeywell zoning systems
ZD18X16 18 in. x 16 in. Rectangular Side power closed, spring open Honeywell zoning systems
ZD18X18 18 in. x 18 in. Square Side power closed, spring open Honeywell zoning systems
Pneumatic Controls

ZD18X20 18 in. x 20 in. Rectangular Bottom power closed, spring open Honeywell zoning systems
ZD18X22 18 in. x 22 in. Rectangular Bottom power closed, spring open Honeywell zoning systems
ZD18X24 18 in. x 24 in. Rectangular Bottom power closed, spring open Honeywell zoning systems
ZD18X26 18 in. x 26 in. Rectangular Bottom power closed, spring open Honeywell zoning systems
ZD20X6 20 in. x 6 in. Rectangular Side power closed, spring open Honeywell zoning systems
ZD20X8 20 in. x 8 in. Rectangular Side power closed, spring open Honeywell zoning systems
ZD20X10 20 in. x 10 in. Rectangular Side power closed, spring open Honeywell zoning systems
Industrial Combustion

ZD20X12 20 in. x 12 in. Rectangular Side power closed, spring open Honeywell zoning systems
Controls

ZD20X14 20 in. x 14 in. Rectangular Side power closed, spring open Honeywell zoning systems
ZD20X16 20 in. x 16 in. Rectangular Side power closed, spring open Honeywell zoning systems

70-6910 51
Zone Control Dampers
Product Number Size (inch) Shape Motor Mount Motor Type Used With
ZD20X18 20 in. x 18 in. Rectangular Side power closed, spring open Honeywell zoning systems
ZD20X20 20 in. x 20 in. Square Side power closed, spring open Honeywell zoning systems
ZD20X22 20 in. x 22 in. Rectangular Bottom power closed, spring open Honeywell zoning systems
ZD20X24 20 in. x 24 in. Rectangular Bottom power closed, spring open Honeywell zoning systems
ZD22X6 22 in. x 8 in. Rectangular Side power closed, spring open Honeywell zoning systems
ZD22X8 22 in. x 8 in. Rectangular Side power closed, spring open Honeywell zoning systems
ZD22X10 22 in. x 10 in. Rectangular Side power closed, spring open Honeywell zoning systems
ZD22X12 22 in. x 12 in. Rectangular Side power closed, spring open Honeywell zoning systems
ZD22X14 22 in. x 14 in. Rectangular Side power closed, spring open Honeywell zoning systems
ZD22X16 22 in. x 16 in. Rectangular Side power closed, spring open Honeywell zoning systems
ZD22X18 22 in. x 18 in. Rectangular Side power closed, spring open Honeywell zoning systems
ZD22X20 22 in. x 20 in. Rectangular Side power closed, spring open Honeywell zoning systems
ZD22X22 22 in. x 22 in. Square Side power closed, spring open Honeywell zoning systems
ZD22X24 22 in. x 24 in. Rectangular Bottom power closed, spring open Honeywell zoning systems
ZD24X6 24 in. x 8 in. Rectangular Side power closed, spring open Honeywell zoning systems
ZD24X8 24 in. x 8 in. Rectangular Side power closed, spring open Honeywell zoning systems
ZD24X10 24 in. x 10 in. Rectangular Side power closed, spring open Honeywell zoning systems
ZD24X12 24 in. x 12 in. Rectangular Side power closed, spring open Honeywell zoning systems
ZD24X14 24 in. x 14 in. Rectangular Side power closed, spring open Honeywell zoning systems
ZD24X16 24 in. x 16 in. Rectangular Side power closed, spring open Honeywell zoning systems
ZD24X18 24 in. x 18 in. Rectangular Side power closed, spring open Honeywell zoning systems
ZD24X20 24 in. x 20 in. Rectangular Side power closed, spring open Honeywell zoning systems
ZD24X22 24 in. x 22 in. Rectangular Side power closed, spring open Honeywell zoning systems
ZD24X24 24 in. x 24 in. Square Side power closed, spring open Honeywell zoning systems
ZD26X8 26 in. x 8 in. Rectangular Side power closed, spring open Honeywell zoning systems
ZD26X10 26 in. x 10 in. Rectangular Side power closed, spring open Honeywell zoning systems
ZD26X12 26 in. x 12 in. Rectangular Side power closed, spring open Honeywell zoning systems
ZD26X14 26 in. x 14 in. Rectangular Side power closed, spring open Honeywell zoning systems
ZD26X16 26 in. x 16 in. Rectangular Side power closed, spring open Honeywell zoning systems
ZD26X18 26 in. x 18 in. Rectangular Side power closed, spring open Honeywell zoning systems
ZD26X20 26 in. x 20 in. Rectangular Side power closed, spring open Honeywell zoning systems
ZD28X6 28 in. x 6 in. Rectangular Side power closed, spring open Honeywell zoning systems
ZD28X8 28 in. x 8 in. Rectangular Side power closed, spring open Honeywell zoning systems
ZD28X10 28 in. x 10 in. Rectangular Side power closed, spring open Honeywell zoning systems
ZD28X12 28 in. x 12 in. Rectangular Side power closed, spring open Honeywell zoning systems
ZD28X14 28 in. x 14 in. Rectangular Side power closed, spring open Honeywell zoning systems
ZD28X16 28 in. x 16 in. Rectangular Side power closed, spring open Honeywell zoning systems
ZD28X20 28 in. x 20 in. Rectangular Side power closed, spring open Honeywell zoning systems

Zoning Damper Accessories


Product Number Size (inch) Description Includes
32006184-001 37 in. Filler Strip Kit Filler strip kit used to install ZD dampers in odd sized ducts 1 1/8 in. x 3/4 in. adhesive-backed foam strips

52 customer.honeywell.com 70-6910
Zone Damper Accessories

Home Controls
AT140 Universal Mount Transformer
The AT140 is a 24V, 40VA universal mount transformer.
• Provides a low voltage power source for any Honeywell zone control
panel or damper
• Powers up to 5 ZD or ARD damper motors and 14 RRD damper
motors from one 40VA transformer
• Mounting options include plate or foot mounting
• 120/240 VAC primary

Indoor Air Quality


Application: Accessory

Combustion Controls
Residential
Product Number Voltage
AT140A1042 120/240V Primary, 24V Secondary 40VA

M847D Damper Actuator


The M847D is a two position, 24 Vac spring return actuator
designed to operate ARD, EARD and ZD zone dampers.

Hydronic Controls
• Low voltage, spring-return damper actuator.
• Equipped with anti-rotation and drive shaft extensions for direct
mounting to 7/16 inch diameter coupling style dampers.
• Adjustable range stops.
• Direct replacement for M847D1004

Application: Damper Actuator


Voltage: 24V
Wires to Motor: 2
Motor Timing: 30 seconds powered/10 seconds spring return
Other Motor Information: Range stops

Controls
Water
Product Number Size (inch) Motor Mount Motor Type Description
M847D1012 4 1/2 in. high x 2 3/8 in. wide Direct connection to damper shaft Spring return Spring Return Damper Actuator
x 3 3/8 in. deep

Building Automation
Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 53
54 customer.honeywell.com 70-6910
Media Air Cleaners
F100F Media Air Cleaner

Controls
Home
The F100F Media Air Cleaner captures a significant amount of the
airborne particles from the air circulated through the unit.
Recommended as the basic minimum air quality product. The
F100F Media Air Cleaner includes cabinet, access door and
FC100A pleated media filter, and W8600A Airwatch Indicator
(optional on some models).
• High efficiency media filter captures particles as small as 0.3

Indoor Air Quality


microns.
• Applicable to all gas, oil and electric forced air furnaces and to
compressor cooling up to 5 tons.
• Mounts in the return air duct.
• Rugged zinc-coated, roll-formed cabinet resists corrosion and can
support weight of residential furnace and evaporator coil.
• Requires no electrical connections.
• Mounts in any position.
• Requires no maintenance except periodic media filter replacement.

Combustion Controls
• Quick and easy media filter replacement.
• Later upgrade to higher performing media or electronic air cleaner is

Residential
easy.

Pressure Drop of FC100 Filter


Type of Air Cleaner: Media Air Cleaner
FILTER SIZE Application: Duct mounted
20 X 25 Efficiency Standard: Efficiency ratings are based on American Society
16 X 25 of Heating, Refrigerating and Air-Conditioning Engineers Standard
20 X 20

Hydronic Controls
16 X 20
52.2-1999.
2 12.5 X 20
Efficiency ranges are defined for small particles, E1=0.3 to 1.0 microns;
0.300 medium particles, E2=1.0 to 3.0 microns; and large particles, E3=3.0
1 to 10.0 microns.
0.250 Minimum Efficiency Reporting Value (Media Filters Only): MERV 10
PRESSURE DROP (IN. WC)

Fractional Efficiency: E1=25%, E2=62%, E3=85%


0.200
Static Pressure Drop (in. w.c.): 0.23 at 500 FPM
0.150 Approvals:
Underwriters Laboratories, Inc. Filter Element: UL Listed, UL900,
0.100 Class 2

Controls
Water
0.050

0.000

0 500 1000 1500 2000


AIRFLOW (CFM)

1 WHEN FIRST INSTALLED. PRESSURE DROP INCREASES AS FILTER

Building Automation
BECOMES LOADED. REPLACE FILTER WHEN PRESSURE DROP
REACHES 0.5 IN. WC. (0.1 kPa).

2 AVAILABLE ONLY IN UNITED STATES. M14709

Air Cleaner Size Dimensions,


Approximate Airflow Max.-Capacity

Product Number (inch) (mm) (cfm) (m3/hr) Replacement Filters


* F100F1004 16 in. x 20 in. 406 mm x 508 mm 1200 cfm 2040 m3/hr FC100A1003, FC200E1003, POPUP1620

* F100F1012 16 in. x 25 in. 406 mm x 635 mm 1400 cfm 2380 m3/hr FC100A1029, FC200E1029, POPUP1625

Components
Commercial
* F100F1020 20 in. x 20 in. 508 mm x 508 mm 1400 cfm 2380 m3/hr FC100A1011, FC200E1011, POPUP2020

* F100F1038 20 in. x 25 in. 508 mm x 635 mm 2000 cfm 3400 m3/hr FC100A1037, FC200E1037, POPUP2025

* F100F2002 16 in. x 25 in. 406 mm x 635 mm 1400 cfm 2380 m3/hr FC100A1029, FC200E1029, POPUP1625

* F100F2010 20 in. x 25 in. 508 mm x 635 mm 2000 cfm 3400 m3/hr FC100A1037, FC200E1037, POPUP2025
Pneumatic Controls

* F100F2028 16 in. x 20 in. 406 mm x 508 mm 1200 cfm 2040 m3/hr FC100A1003, FC200E1003, POPUP1620

* F100F2036 20 in. x 20 in. 508 mm x 508 mm 1400 cfm 2380 m3/hr FC100A1011, FC200E1011, POPUP2020

* F100F2044 25 in. x 20 in. 635 mm x 508 mm 2000 cfm 3400 m3/hr FC100A1037, FC200E1037, FC100C1017
* F100F2051 25 in. x 22 in. 635 mm x 559 mm 2000 cfm 3400 m3/hr FC100A1037, FC200E1037, FC100C1017
* TRADELINE models • SUPER TRADELINE models
Industrial Combustion
Controls

70-6910 55
Media Air Cleaners
Dimensions in inches (millimeters)

1-1/8 (29)

DIM. B
DIM. A (SEE TABLE)
(SEE TABLE)

6-3/4 7/8
(171) 7/8 DIM. C (SEE TABLE) (22)
(22) 5/8
(16) DIM. D (SEE TABLE)

F100 SIZE DIM. A DIM. B DIM. C DIM. D


IN. MM IN. MM IN. MM IN. MM IN. MM
16 X 25 406 X 635 14 7/16 367 16 3/16 411 23 1/4 591 25 1/2 648
16 X 20 406 X 508 14 7/16 367 16 3/16 411 18 1/4 457 20 1/2 521
20 X 25 508 X 635 18 7/16 468 20 3/16 513 23 1/4 591 25 1/2 648
20 X 20 508 X 508 18 7/16 468 20 3/16 513 18 1/4 457 20 1/2 521
25 X 20 635 X 508 23 5/16 592 25 1/8 638 18 3/8 467 20 5/8 524
25 X 22 635 X 559 23 5/16 592 25 1/8 638 20 1/4 514 22 1/2 572
M14710D

56 customer.honeywell.com 70-6910
Media Air Cleaners
F200 Media Air Cleaner

Controls
Home
The F200E Media Air Cleaner captures a significant amount of the
airborne particles from the air circulated through the unit.
Recommended high efficiency media air quality product. The
F200E Media Air Cleaner includes cabinet, access door and
FC200E pleated media filter, and W8600B RF Airwatch Indicator.
• W8600B RF AIRWATCH filter change indicator included.
• Integral pressure sensors signal when filter change is required

Indoor Air Quality


based on increased pressure drop threshold at filter.
• Filter change status is transmitted to wall-mounted RF AIRWATCH
Indicator.
• High efficiency charged-media filter captures particles as small as
0.3 microns.
• Applicable to all gas, oil and electric forced air furnaces and to
compressor cooling up to 5 tons.
• Mounts in the return air duct.
• Rugged zinc-coated, roll-formed cabinet resists corrosion and can

Combustion Controls
support weight of residential furnace and evaporator coil.
• Requires no electrical connections.

Residential
• Mounts in any position.
• Requires no maintenance except periodic media filter replacement.
• Quick and easy media filter replacement.
• Later upgrade to higher performing media or electronic air cleaner is
easy.

Pressure Drop of FC200 Filter


Type of Air Cleaner: Media Air Cleaner

Hydronic Controls
16 x 25 in. Application: Duct mounted
(406 x 635 mm) Efficiency Standard: Efficiency ratings are based on American Society
20 x 20 in.
(508 x 508 mm) of Heating, Refrigerating and Air-Conditioning Engineers Standard
0.4 52.2-1999.
16 x 20 in. Efficiency ranges are defined for small particles, E1=0.3 to 1.0 microns;
1 (406 x 508 mm) medium particles, E2=1.0 to 3.0 microns; and large particles, E3=3.0
0.3 to 10.0 microns.
PRESSURE DROP (IN. WC)

Minimum Efficiency Reporting Value (Media Filters Only): MERV 13


Fractional Efficiency: E1=63%, E2=91%, E3=99%
0.2 Static Pressure Drop (in. w.c.): 0.3 at 500 FPM

Controls
Approvals:

Water
20 x 25 in.
(508 x 635 mm) Underwriters Laboratories, Inc. Filter Element: UL Listed, UL900,
0.1 Class 2

Building Automation
0 500 1000 1500 2000
AIRFLOW (CFM)

1 WHEN FIRST INSTALLED. PRESSURE DROP INCREASES AS FILTER


BECOMES LOADED. REPLACE FILTER WHEN PRESSURE DROP
REACHES 0.5 IN. WC. (0.1 kPa). M13662

Air Cleaner Size Dimensions,


Approximate Airflow Max.-Capacity

Product Number (inch) (mm) (cfm) (m3/hr) Replacement Filters

Components
* F200E1003 16 in. x 20 in. 406 mm x 508 mm 1200 cfm FC100A1003, FC200E1003, POPUP1620

Commercial
3/hr
2040 m
* F200E1011 20 in. x 20 in. 508 mm x 508 mm 1400 cfm 2380 m3/hr FC100A1011, FC200E1011, POPUP2020

* F200E1029 16 in. x 25 in. 406 mm x 635 mm 1400 cfm 2380 m3/hr FC100A1029, FC200E1029, POPUP1625

* F200E1037 20 in. x 25 in. 508 mm x 635 mm 2000 cfm 3400 m3/hr FC100A1037, FC200E1037, POPUP2025
* TRADELINE models • SUPER TRADELINE models
Pneumatic Controls
Industrial Combustion
Controls

70-6910 57
Media Air Cleaners
Dimensions in inches (millimeters)

1-1/8 (29)

DIM. A
(SEE DIM. B
TABLE) (SEE TABLE)

7/8
(22)

7/8
6-3/4 (22)
(171) 5/8 DIM. C (SEE TABLE)
(16)
2-1/2 DIM. D (SEE TABLE)
(63)

F200E SIZE DIM. A DIM. B DIM. C DIM. D


IN. MM IN. MM IN. MM IN. MM IN. MM
16 X 25 406 X 635 14 7/16 367 16 3/16 411 23 1/4 591 25 648
16 X 20 406 X 508 14 7/16 367 16 3/16 411 18 1/4 457 20 521
20 X 25 508 X 635 18 7/16 468 20 3/16 513 23 1/4 591 25 648
20 X 20 508 X 508 18 7/16 468 20 3/16 513 18 1/4 457 20 521
M14784C

58 customer.honeywell.com 70-6910
Electronic Air Cleaners
F300 Electronic Air Cleaner

Controls
Home
Capturing up to 98% of particles (3.0 - 10.0 micron) that pass
through the filter, the F300 offers the highest level of filtration on
the market. It is widely compatible, operating with all gas, oil and
electric forced warm air furnaces and air-conditioning systems,
and is also available in four convenient sizes to fit most ducts.
• Media post-filter provides enhanced filtration.
• Solid state power supply is self-regulating and maintains peak

Indoor Air Quality


efficiency during a wide range of cell dirt loading conditions.
• New low-profile door with test button to check system operation.
• Helps filter efficiency-robbing "gunk" before it coats critical system
parts.
• Very low pressure drop.
• Exclusive wireless W8600A AIRWATCH indicator reminds
customers when to wash cells to keep the unit operating at peak
efficiency, as well as when to change UV Lamps and Humidifier
Pads (optional).

Combustion Controls
• Exclusive 10-year Clean Coil Guarantee.
• Rugged zinc-coated, roll-formed cabinet provides superior strength

Residential
and corrosion protection.

Type of Air Cleaner: Electronic Air Cleaner Accessories:


Application: Duct mounted

Hydronic Controls
W8600A1007 AIRWATCH indicator for use with F100F, F200 or
Efficiency Standard: Efficiency ratings are based on American Society F300A,E
of Heating, Refrigerating and Air-Conditioning Engineers Standard W8600F1014 White EAC Performance indicator for use with F50F or
52.2-1999. F300E
Efficiency ranges are defined for small particles, E1=0.3 to 1.0 microns;
medium particles, E2=1.0 to 3.0 microns; and large particles, E3=3.0 Replacement Parts:
to 10.0 microns. 4074EHG FC37A Terminal Board Repair Kit. Contains 2 connector
Frequency: 60 Hz clips, 1 Terminal Board and instruction sheet
FC37A1049 Electronic Air Cleaner Cell, 9.8 x 20
Approvals:
FC37A1064 Electronic Air Cleaner Cell, 12.4 x 20
Underwriters Laboratories, Inc. Listed: Report E30954
FC37A1114 Electronic Air Cleaner Cell, 9.8 x 16
FC37A1130 Electronic Air Cleaner Cell, 12.4 x 16

Controls
Water
203365A Conversion Kit for changing 120V Power Supply to 240V
50000293-001 16x10 Post Filter for 16x20 F300E and F50F
50000293-002 16x12.5 Post Filter for 16x25 F300E and F50F
50000293-003 20x10 Post Filter for 20x20 F300E and F50F
50000293-004 20x12.5 Post Filter for 20x25 and 20x12.5 F300E and
F50F

Building Automation
Air Cleaner Size
Dimensions, Airflow Max.-
Approximate Capacity
Electrical Fractional Static Pressure Replacement
Product Number (inch) (mm) (cfm) (m3/hr) Ratings Efficiency Drop (in. w.c.) Filters Comments
* F300A1620 16 in. x 406 mm x 1200 cfm 2040 m3/hr 120 Vac, E1=73%, E2=88%, 0.15 at 500 FPM 50000293-001 —
20 in. 508 mm 0.4A max. E3=95%
* F300A1625 16 in. x 406 mm x 1400 cfm 2380 m3/hr 120 Vac, E1=73%, E2=88%, 0.15 at 500 FPM 50000293-002 —
25 in. 635 mm 0.4A max. E3=95%

Components
Commercial
* F300A2012 20 in. x 508 mm x 875 cfm 1487 m3/hr 120 Vac, E1=73%, E2=88%, 0.15 at 500 FPM 50000293-004 —
12 1/2 in. 318 mm 0.4A max. E3=95%
* F300A2020 20 in. x 508 mm x 1400 cfm 2380 m3/hr 120 Vac, E1=73%, E2=88%, 0.15 at 500 FPM 50000293-003 —
20 in. 508 mm 0.4A max. E3=95%
* F300A2025 20 in. x 508 mm x 2000 cfm 3400 m3/hr 120 Vac, E1=73%, E2=88%, 0.15 at 500 FPM 50000293-004 —
25 in. 635 mm 0.4A max. E3=95%
* F300B2012 20 in. x 508 mm x 875 cfm 1487 m3/hr 240 Vac, E1=73%, E2=88%, 0.15 at 500 FPM 50000293-004 —
Pneumatic Controls

12 1/2 in. 318 mm 0.2A max. E3=95%


* F300E1001 16 in. x 406 mm x 1200 cfm 2040 m3/hr 120 Vac, E1=81%, E2=93%, 0.26 at 500 FPM 50000293-001 Enhanced
20 in. 508 mm 0.4A max. E3=99% Filtration
* F300E1019 16 in. x 406 mm x 1400 cfm 2380 m3/hr 120 Vac, E1=81%, E2=93%, 0.26 at 500 FPM 50000293-002 Enhanced
25 in. 635 mm 0.4A max. E3=99% Filtration
* F300E1027 20 in. x 508 mm x 1400 cfm 2380 m3/hr 120 Vac, E1=81%, E2=93%, 0.26 at 500 FPM 50000293-003 Enhanced
20 in. 508 mm 0.4A max. E3=99% Filtration
* F300E1035 20 in. x 508 mm x 2000 cfm 3400 m3/hr 120 Vac, E1=81%, E2=93%, 0.26 at 500 FPM 50000293-004 Enhanced
Industrial Combustion

25 in. 635 mm 0.4A max. E3=99% Filtration


* TRADELINE models • SUPER TRADELINE models
Controls

70-6910 59
Electronic Air Cleaners
Dimensions in inches (millimeters)

6 3 (162)
8
ELECTRONIC AIR CLEANER

DIM. E (SEE TABLE)

DIM. B
DIM. A (SEE TABLE)
(SEE TABLE)

7
3 (172) 7 DIM. C (SEE TABLE) 8
6
4 8 5 (22)
DIM. D (SEE TABLE)
(22) 8
(16)

F50F SIZE DIM. A DIM. B DIM. C DIM. D DIM. E


IN. MM IN. MM IN. MM IN. MM IN. MM IN. MM
16 X 25 406 X 635 14 7/16 367 16 3/16 411 23 1/4 591 25 1/2 648 2 3/4 70
16 X 20 406 X 508 14 7/16 367 16 3/16 411 18 1/4 457 20 1/2 521 2 3/4 70
20 X 25 508 X 635 18 7/16 468 20 3/16 513 23 1/4 591 25 1/2 648 2 3/4 70
20 X 20 508 X 508 18 7/16 468 20 3/16 513 18 1/4 457 20 1/2 521 2 3/4 70
20 X 12 1/2 508 X 318 18 7/16 468 20 3/16 513 10 7/8 276 13 1/8 333 3 5/8 92
M2872B

60 customer.honeywell.com 70-6910
Electronic Air Cleaners
Pressure Drop versus Airflow

Controls
Home
AIR CLEANER EFFICIENCY AND PRESSURE DROP AT VARIOUS AIRFLOW RATES.

WITHOUT POST FILTERS


.25
(62.2)
16 x 20 in.
(406 x 508 mm)

PRESSURE DROP IN in. wc (Pa)

Indoor Air Quality


.20
(49.7)

16 x 25 in. 20 x 25 in.
(508 x 635 mm) .15
(406 x 635 mm) (37.3)
20 x 20 in.
20 x 12-1/2 in. (508 x 508 mm)
(508 x 318 mm) .10
(24.9)

Combustion Controls
4 .05
(12.4)

Residential
1
2 3 0
400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000
(680) (850) (1020) (1190) (1360) (1530) (1700) (1870) (2040) (2210) (2380) (2550) (2720) (2890) (3060) (3230) (3400)
CAPACITY IN cfm (m3 /hr)

WITH POST FILTERS .35


(87.2)

Hydronic Controls
.30
(74.7)
16 x 20 in.
(406 x 508 mm)
.25
20 x 12-1/2 in. (62.2)
(508 x 318 mm) 20 x 20 in.
(508 x 508 mm)

PRESSURE DROP IN in. wc (Pa)


20 x 25 in. .20
(508 x 635 mm) (49.7)
16 x 25 in.
(406 x 635 mm)

Controls
.15

Water
(37.3)

.10
(24.9)

.05
(12.4)

Building Automation
0
400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000
(680) (850) (1020) (1190) (1360) (1530) (1700) (1870) (2040) (2210) (2380) (2550) (2720) (2890) (3060) (3230) (3400)

CAPACITY IN cfm (m3 /hr)

1 MINIMUM RECOMMENDED cfm FOR 20 x 12-1/2 in. (508 x 318 mm) MODEL. 3 MINIMUM RECOMMENDED cfm FOR 20 x 25 in. (508 x 635 mm) MODEL.
2 MINIMUM RECOMMENDED cfm FOR 16 x 25 in. (406 x 635 mm), 4 SELECT SIZE THAT MOST CLOSELY FITS DIMENSIONS OF
20 x 20 in. (508 x 508 mm), 16 x 20 in. (406 x 508 mm) MODELS. FURNACE/AIR HANDLER RETURN AIR OPENING
M13654

Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 61
Electronic Air Cleaners
F300E Exploded View

10

14

20
17

13

12
7

11

19

22

21

3
2

1 M18846D

62 customer.honeywell.com 70-6910
Electronic Air Cleaner Filters

Controls
Home
Nominal Return Air Opening
16 x 20 in. 16 x 25 in. 20 x 12-1/2 in. 20 x 20 in. 20 x 25 in.
No. Description (406 x 508 mm) (406 x 635 mm) (508 x 318 mm) (508 x 508 mm) (508 x 635 mm)
1 F50 Access Door includes No. 2 203306AB (1) 203306AB (1) 203305AB (1) 203305AB (1) 203305AB (1)
1 F300 Access Door includes No. 2 32007528-003 32007528-003 32007528-002 32007528-002 32007528-002

Indoor Air Quality


2 Test Button Assembly 137980A (1) 137980A (1) 137980A (1) 137980A (1) 137980A (1)
3 Electronic Cell FC37A1114 (2) FC37A1130 (2) FC37A1064 (1) FC37A1049 (2) FC37A1064 (2)
4 Cell Handle 137266 (2) 137266 (2) 137266 (1) 137266 (2) 137266 (2)
5 Prefilter (without spring clips) 209989 (2) 203368 (2) 203369 (1) 203370 (2) 203369 (2)
6 Cell Key 136518 (1) 136518 (1) 136518 (1) 136518 (1) 136518 (1)
7 F50 Power Box Assembly Series Onea. 208418Gc (1) 208417Qc (1) 208419Dd (1) 208418Fc (1) 208417Qc (1)
Includes No. 8-20, 120V, 60 Hz. Brown Cover.

Combustion Controls
7 F300 Power Box Assembly Series Twob. 208418J (1) 208417S (1) 208419Dd 208418H (1) 208417R (1)

Residential
Includes No. 8-20, 120V, 60 Hz. White Cover.
8 Switch 203321 (1) 203321 (1) 203321 (1) 203321 (1) 203321 (1)
10 F50 and F300 Power Supply, Series Twob. 208045Jc (1) 208045Gc (1) 208045G (1) 208045Gc (1) 208045Gc (1)
120V, 60 Hz
11 Interlock Bracket and Switch 4074ETG (1) 4074ETG (1) 4074ETG (1) 4074ETG (1) 4074ETG (1)
12 W8600 Terminal Strip Supplied with W8600F

Hydronic Controls
13 Terminal Board Assembly Front 203329B (1) 203329B (1) N/A 203329B (1) 203329B (1)
14 Terminal Board Assembly Rear 203329A (1) 203329A (1) N/A 203329A (1) 203329A (1)
17 Line Cord 4074ETD (1) 4074ETD (1) 4074ETD (1) 4074ETD (1) 4074ETD (1)
19 Neon Assembly 4074EYS (1) 4074EYS (1) 4074EYS (1) 4074EYS(1) 4074EYS (1)
20 Airflow Switch, pin connection 4074ETH (1) 4074ETH (1) 4074ETH (1) 4074ETH (1) 4074ETH (1)
20 Airflow Switch, plug connection 4074EZB (1) 4074EZB (1) N/A 4074EZB (1) 4074EZB (1)
21 FC37A Bag Assembly for cell repair. 4074EHG 4074EHG 4074EHG 4074EHG 4074EHG
Contains
2 Connector Clips,

Controls
Water
1 Terminal Board and Instructions.
22 Post Filter (not included with F300A) 50000293-001 50000293-002 50000293-004 50000293-003 50000293-004
a
Series One compatible with W8600E and W8600F.
b
Series Two compatible with W8600F only.
c
Use 203365A Conversion Kit for changing 120V, 60Hz model to 240V, 60 Hz.

Building Automation
d
Change from brown cover to white cover as a running change. Use original cover for color match.

Parts and Accessories Not Illustrated


Nominal Return Air Opening
16 x 20 in. 16 x 25 in. 20 x 12-1/2 in. 20 x 20 in. 20 x 25 in.
Description (406 x 508 mm) (406 x 635 mm) (508 x 318 mm) (508 x 508 mm) (508 x 635 mm)
Ionizer Wires (multiples of 5) 136434BA 136434BA 136434AA 136434AA 136434AA
Premier White® AIRWATCH® Indicator W8600A1007 W8600A1007 W8600A1007 W8600A1007 W8600A1007

Components
Commercial
Premier White® Air Cleaner Monitor W8600F1014 W8600F1014 W8600F1014 W8600F1014 W8600F1014
240V Conversion Kit 203365A 203365A N/A 203365A 203365A
(#) = Quantity required per unit
N/A = Not available as merchandised part.

EAC Media Post Filter


Pneumatic Controls

Our high-efficiency, charged post-filters boost the efficiency of any


Honeywell electronic air cleaner with negligible effect on pressure Type of Air Cleaner: Electronic Air Cleaner
drop. Application: Replacement Filter

Product Number Description Used With


50000293-001 High air flow media post-filter for EAC, 16x10 F300, F50F
Industrial Combustion

50000293-002 High air flow media post-filter for EAC, 16x12.5 F300, F50F
50000293-003 High air flow media post-filter for EAC, 20x10 F300, F50F
Controls

50000293-004 High air flow media post-filter for EAC, 20x12.5 F300, F50F

70-6910 63
Return Grille Electronic Air Cleaners
F52 Return Grille Electronic Air Cleaner
The F52F Return Grille Electronic Air Cleaner is wall or ceiling
mounted in the main return air duct of a central forced air heating,
cooling, or ventilation system. It captures a significant number of
the airborne particles (0.5 microns and larger) from the air
circulated through the cell(s).
• Removes airborne particles from the air circulated through it.
• Electronic cells can be washed easily.
• Neon light shows that air cleaner is operating.
• Wiring consists of simply connecting air cleaner to power source.
• Solid state power supply is energized by an airflow switch; no
interconnection to the fan system is required.
• Solid state power supply is self-regulating and maintains peak
efficiency during a wide range of cell dirt loading conditions.
• Automatic interlock switch disconnects power when unit is opened.
• Use with optional W8600F Electronic Air Cleaner Monitor (ordered
separately) to monitor air cleaner performance.

Type of Air Cleaner: Electronic Air Cleaner Approvals:


Application: Return Grill Underwriters Laboratories, Inc. Listed: Report E30954
Efficiency Standard: Efficiency ratings are based on American Society
of Heating, Refrigerating and Air-Conditioning Engineers Standard
Replacement Parts:
136434AA 20 in. Replacement Ionizer wire
52.2-1999.
190912A Contact Board Assembly
Efficiency ranges are defined for small particles, E1=0.3 to 1.0 microns;
4074EHG FC37A Terminal Board Repair Kit. Contains 2 connector
medium particles, E2=1.0 to 3.0 microns; and large particles, E3=3.0
clips, 1 Terminal Board and instruction sheet
to 10.0 microns.
4074ETE Neon Light Assembly, includes lens and wire tie
Fractional Efficiency: E1=73%, E2=88%, E3=95%
4074ETH Air Flow Switch Bag Assembly, with pin connections
Static Pressure Drop (in. w.c.): 0.2 at max flow
FC37A1171 Electronic Air Cleaner Cell, 12.4 x 20

Air Cleaner Size Dimensions, Approximate Airflow Max.-Capacity

Product Number (inch) (mm) (cfm) (m3/hr) Electrical Ratings Frequency


* F52F1048 20 in. x 12 1/2 in. 508 mm x 318 mm 1000 cfm 1700 m 3/hr 120 Vac, 0.4A max. 60 Hz

* F52F1055 20 in. x 25 in. 508 mm x 635 mm 2000 cfm 3400 m3/hr 120 Vac, 0.4A max. 60 Hz
* TRADELINE models • SUPER TRADELINE models
Pressure Drop and Efficiency versus Airflow

.25 (62) .25 (62)


.20 (50) .20 (50)
1 1
PRESSURE DROP IN IN. WC (PA)

PRESSURE DROP IN IN. WC (PA)


.15 (37) .15 (37)
EFFICIENCY, PERCENT
EFFICIENCY, PERCENT

.10 (25) .10 (25)


.05 (13) .05 (13)

100 0 (0) 100 0 (0)

90 90
80 80
70 70
60 60
50 50
400 500 600 700 800 900 1000 800 1000 1200 1400 1600 1800 2000
(680) (850) (1020) (1190) (1360) (1530) (1700) (1360) (1700) (2040) (2350) (2720) (3060) (3400)
F52F ONE CELL CAPACITY IN cfm (m3/hr) F52F TWO CELL CAPACITY IN cfm (m3 /hr)

1 EFFICIENCY RATINGS BASED ON NATIONAL BUREAU OF STANDARDS DUST SPOT METHOD USING ATMOSPHERIC DUST
M7824
AND AMERICAN SOCIETY OF HEATING, REFRIGERATION, AND AIR-CONDITIONING ENGINEERS STANDARD 52.1-92.

64 customer.honeywell.com 70-6910
Return Grille Electronic Air Cleaners
Dimensions in inches (millimeters)

Controls
Home
29-1/16 (738)
23-1/8
(587) 17-5/16
(440) 11-1/2
(292) 5-5/8
(143)
3/16 (5)
(8)

Indoor Air Quality


13/16 (21)
11/16 (18)

7 (178)
2-1/2 (64)
1-1/2 (38)
31 (787)
A

Combustion Controls
4-1/16

Residential
1-1/4 (103)
(32)
10-3/4 22
(273) 8-1/16 (559)
3/16 (205)
(5)
(7)
24 13-5/8
(610) (346)

Hydronic Controls
17-11/16
(449)

1-1/2
(38)
3/4 (19)
7/8 (22)

3/4 KNOCKOUT FOR


KNOCKOUT FOR 1/2 INCH CONDUIT
(19) 3-3/8 1/2 INCH CONDUIT
CONNECTOR ON BACK OF F52
(86) CONNECTOR
M23235

Controls
Water
Building Automation
Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 65
Return Grille Electronic Air Cleaners
F52F Exploded View

Part Number Parts and Accessories not Illustrated


120 Vac Model Part Number
No. Description F52F1048 1-Cell 52F1055 2-Cell No. Description 120 Vac Model
1 Prefilter 208536 208537 16 Cell Handle 137266
3 Electronic Cell FC37A1171 FC37A1171 (2) 17 Ionizer Wires (Must be ordered 136434AA (9/cell)
in multiples of 5.)
4 Air Flow Switch 4074ETH 4074ETH
6 Cell Contact Board 4074EHG 4074EHG (2) 21 Air Cleaner Monitor, Premier White® W8600F1014

7 Cabinet Contact Board 190912A 190912A (2)


8 On/Off Switch 203321 203321
9 Interlock Switch 208543 208543
10 Power Supply Series Onea 208427J 208427AA
Power Supply Series Two b NA 208416AA
11 Plastic Door Latch 207631 (2) 207631 (2)
ONE-CELL MODEL
14 Neon Lamp Assembly 4074ETE 4074ETE
a
Series One compatible with W8600E only.
b Series Two compatible with W8600F only.

7 3
6

9
14
8

1 4 10

11

TWO-CELL MODEL
6
7
9
10
3

14

11

M23211B

66 customer.honeywell.com 70-6910
HEPA Air Cleaners
F500 Whole House HEPA Air Cleaner

Controls
Home
passes through the filter. The F500 Whole House Filtration System
includes HEPA filter, 2 in. pleated prefilter, carbon-odor filter and
motor/blower. Isolation mounting straps and HEPA AIRWATCH
Indicator are also included. F500A: Standard cabinet for mounting
in conditioned spaces. F500B: Insulated cabinet for mounting in
unconditioned spaces.
• HEPA media captures at least 99.97% of 0.3 micron particles that

Indoor Air Quality


pass through it.
• Application for forced air systems or stand-alone.
• Power cord plugs into grounded 120 Vac electrical outlet.
• Requires no maintenance except periodic media filter replacement.
• Quiet operation.
• Quick and easy media filter replacement.
• Wall-mounted AIRWATCH Indicator (included) provides filter change
reminders for each of the three filters.
• Easy installation.

Combustion Controls
• Three-filter system:
• Activated carbon filter for odors.

Residential
• High-efficiency pleated pre-filter extends HEPA filter life.
The F500 Whole House HEPA Air Cleaner connects to the return air • HEPA filter traps at least 99.97% of 0.3 micron particles that pass
duct of a forced air system or can be independently ducted. The through it.
HEPA filter captures 99.97% of the particles from the air that • Rugged steel cabinet.

Type of Air Cleaner: HEPA Air Cleaner Fractional Efficiency: 99.97% (at 0.3 microns)
Application: Bypass Stand Alone
Approvals:
Efficiency Standard: HEPA rating is based on IEST-RP-CC001.4

Hydronic Controls
Canadian Standards Association: Certified
standard for testing HEPA filters.

Airflow Max.-Capacity

Product Number (cfm) (m3/hr) Electrical Ratings Frequency Replacement Filters


* F500A1000 400 cfm 680 m3/hr 120 Vac, 1.98A max. 60 Hz 32006026-001 Carbon Odor Filter (4 Pack), 32006027-001 2
nominal nominal inch Prefilter, 32006028-001 HEPA Filter
* F500B1009 400 cfm 680 m3/hr 120 Vac, 1.98A max. 60 Hz 32006026-001 Carbon Odor Filter (4 Pack), 32006027-001 2
nominal nominal inch Prefilter, 32006028-001 HEPA Filter

Controls
* TRADELINE models • SUPER TRADELINE models

Water
Dimensions in inches (millimeters)

MOUNTING STRAP

Building Automation
25-1/2 12-1/2
(648) (328)

Components
Commercial
19
(483)

4
(102)
Pneumatic Controls

10
PROVIDE 26-1/2 (673) SERVICE CLEARANCE IN FRONT OF UNIT (254) M23246
Industrial Combustion
Controls

70-6910 67
HEPA Air Cleaners
F500 Exploded View

TM

On/Battery
Odor Filter
Prefilter
HEPA Filter
Whole House HEPA Filtration System
Honeywell.com/yourhome

No. Description Part Number


1 HEPA AIRWACH™ Indicator 32005012-001
2 Blower Motor Assembly 32006670-001

3 Carbon-Odor Filter 32006026-001


4 Pleated Prefilter 32006027-001

5 HEPA Filter 32006028-001


M23212

HEPA Replacement Media


HEPA stands for high-efficiency particulate arresting. Honeywell
HEPA air cleaners offer powerful filtration: They capture 99.97% of Type of Air Cleaner: HEPA Air Cleaner
particles that are 0.3 microns in size from the air that passes Application: Replacement Filter
through the filter.

Product Number Description Used With


32006026-001 Carbon Filter for Whole House HEPA Air Cleaner F500
32006027-001 2 inch Prefilter for Whole House HEPA Air Cleaner F500
32006028-001 HEPA Filter for Whole House HEPA Air Cleaner F500

68 customer.honeywell.com 70-6910
Replacement Media Filters
Residential Air Cleaner POPUP Replacement Media Filter

Controls
Home
• Save space on the truck.
• Less damage during storage.
• Save time on assembly.
• So easy you can sell over-the-counter to homeowners without worry
of mistakes.
• Compact shape makes PopUP easy to ship.
• No combs, pleat spacers or end caps.

Indoor Air Quality


Type of Air Cleaner: Media Air Cleaner
Application: Replacement Filter
Efficiency Standard: Efficiency ratings are based on American Society
of Heating, Refrigerating and Air-Conditioning Engineers Standard
52.2-1999.
Efficiency ranges are defined for small particles, E1=0.3 to 1.0 microns;
medium particles, E2=1.0 to 3.0 microns; and large particles, E3=3.0

Combustion Controls
to 10.0 microns.
Minimum Efficiency Reporting Value (Media Filters Only): MERV 11

Residential
Air Cleaner Size Dimensions,
Approximate
Product Number (inch) (mm) Description Used With
POPUP1620 16 in. x 20 in. 406 mm x 508 mm 16X20 Media Air Filter Honeywell 16X20 F100 and F200 Media Air Cleaners
POPUP1625 16 in. x 25 in. 406 mm x 635 mm 16X25 Media Air Filter Honeywell 16X25 F100 and F200 Media Air Cleaners

Hydronic Controls
POPUP2020 20 in. x 20 in. 508 mm x 508 mm 20X20 Media Air Filter Honeywell 20X20 F100 and F200 Media Air Cleaners
POPUP2025 20 in. x 25 in. 508 mm x 635 mm 20X25 Media Air Filter Honeywell 20X25 F100 and F200 Media Air Cleaners. Does
not work with 25X20 or 25X22 Media Air Cleaners.
* POPUP2200 20 1/4 in. x 24 1/4 in. 514 mm x 616 mm x Replacement Filter for SpaceGard 2200, 2120, 2250, Lennox PMAC20,
x 5 7/8 in. 149 mm Space-Guard model 201 GeneralAire AC-1
* POPUP2400 16 in. x 27 1/8 in. x 406 mm x 689 mm x Replacement Filter for SpaceGard 2400, 2140, Lennox PMAC12
5 7/8 in. 149 mm Space-Guard model 401
* TRADELINE models • SUPER TRADELINE models

Controls
Water
Building Automation
Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 69
Replacement Media Filters
Residential Air Cleaner Replacement Media Filter
Honeywell cartridge filters provide high efficiency, low pressure
drop and long life. The filters capture a significant amount of the
airborne particles in the air that circulate through the filter.
• High filtration efficiency.
• Low pressure drop.
• Easy to install.
• Long life.
• UL listed.
• Replacement filter for Space-Gard or Aprilaire Models 2200 or 2400.

Type of Air Cleaner: Media Air Cleaner


Application: Replacement Filter
Efficiency Standard: Efficiency ratings are based on American Society
of Heating, Refrigerating and Air-Conditioning Engineers Standard
52.2-1999.
Static Pressure Drop (in. w.c.): 0.25 at 500 FPM

Air Cleaner Size Dimensions, Minimum


Approximate Static Efficiency
Pressure Reporting
Fractional Drop Value (Media
Product Number (inch) (mm) Efficiency (in. w.c.) Filters Only) Used With
CF100A1017 20 in. x 24 in. 508 mm x 610 mm — 0.25 at 500 MERV 8 Air Bear Media Air Cleaners
FPM
FC100A1003 16 in. x 20 in. 406 mm x 508 mm E1=25%, 0.23 at 500 MERV 10 Honeywell 16X20 F100 and F200 Media
E2=62%, E3=85% FPM Air Cleaners
FC100A1011 20 in. x 20 in. 508 mm x 508 mm E1=25%, 0.23 at 500 MERV 10 Honeywell 20X20 F100 and F200 Media
E2=62%, E3=85% FPM Air Cleaners
FC100A1029 16 in. x 25 in. 406 mm x 635 mm E1=25%, 0.23 at 500 MERV 10 Honeywell 16X25 F100 and F200 Media
E2=62%, E3=85% FPM Air Cleaners
FC100A1037 20 in. x 25 in. 508 mm x 635 mm E1=25%, 0.23 at 500 MERV 10 Honeywell 20X25, 25X20, 25X22 F100
E2=62%, E3=85% FPM and F200 Media Air Cleaners,
SpaceGard 2200
FC100A1045 21 1/2 in. x 546 mm x 699 mm E1=25%, 0.23 at 500 MERV 10 F27F1057
27 1/2 in. E2=62%, E3=85% FPM
FC100A1052 20 in. x 12 1/2 in. 508 mm x 318 mm E1=25%, 0.23 at 500 MERV 10 F27F1032
E2=62%, E3=85% FPM
FC200E1003 16 in. x 20 in. 406 mm x 508 mm E1=63%, 0.28 at 500 MERV 13 Honeywell 16X20 F100 and F200 Media
E2=90%, E3=97% FPM Air Cleaners
FC200E1011 20 in. x 20 in. 508 mm x 508 mm E1=63%, 0.28 at 500 MERV 13 Honeywell 20X20 F100 and F200 Media
E2=90%, E3=97% FPM Air Cleaners
FC200E1029 16 in. x 25 in. 406 mm x 635 mm E1=63%, 0.28 at 500 MERV 13 Honeywell 16X25 F100 and F200 Media
E2=90%, E3=97% FPM Air Cleaners
FC200E1037 20 in. x 25 in. 508 mm x 635 mm E1=63%, 0.28 at 500 MERV 13 Honeywell 20X25, 25X20, 25X22 F100
E2=90%, E3=97% FPM and F200 Media Air Cleaners,
SpaceGard 2200
* FC2200A1009 20 1/4 in. x 514 mm x 616 mm E1=19%, 0.21 at 500 MERV 10 SpaceGard 2200
24 1/4 in. x 5 7/8 in. x 149 mm E2=54%, E3=86% FPM
* FC2400A1005 16 in. x 27 1/8 in. x 406 mm x 689 mm E1=19%, 0.21 at 500 MERV 10 SpaceGard 2400
5 7/8 in. x 149 mm E2=54%, E3=86% FPM
* TRADELINE models • SUPER TRADELINE models

70 customer.honeywell.com 70-6910
Replacement Media Filters
Return Grille Media Air Filter

Controls
Home
The Return Grille Filter provides high efficiency, long life
alternative to a 1 in. filter. It captures a significant amount of the
airborne particles in the air that circulates through the filter.
• Mounts in most return filter grilles.
• Pleated for greater media capacity.
• Low pressure drop provides a comfortable air flow.
• Maintains equipment efficiency longer than standard filters.

Indoor Air Quality


• FC40 is MERV 10.
• FC20 is MERV 8.

Type of Air Cleaner: Media Air Cleaner


Application: Return Grill
Efficiency Standard: Efficiency ratings are based on American Society
of Heating, Refrigerating and Air-Conditioning Engineers Standard
52.2-1999.
Efficiency ranges are defined for small particles, E1=0.3 to 1.0 microns;

Combustion Controls
medium particles, E2=1.0 to 3.0 microns; and large particles, E3=3.0

Residential
to 10.0 microns.
Fractional Efficiency: E1=18%, E2=57%, E3=75%
Static Pressure Drop (in. w.c.): 0.18 at 300FPM

Air Cleaner Size Dimensions, Airflow Max.- Minimum


Approximate Capacity Efficiency

Hydronic Controls
Reporting Value
Static Pressure (Media Filters
Product Number (inch) (mm) (cfm) (m3/hr) Fractional Efficiency Drop (in. w.c.) Only)
FC20R1625 16 in. x 25 in. 406 mm x 635 mm 1150 cfm 1950 m3/hr E1=18%, E2=57%, E3=75% 0.18 at 300FPM MERV 8

FC20R2020 20 in. x 20 in. 508 mm x 508 mm 1150 cfm 1950 m3/hr E1=18%, E2=57%, E3=75% 0.18 at 300FPM MERV 8

FC20R2025 20 in. x 25 in. 508 mm x 635 mm 1450 cfm 2460 m3/hr E1=18%, E2=57%, E3=75% 0.18 at 300FPM MERV 8

FC20R2030 20 in. x 30 in. 508 mm x 762 mm 1800 cfm 3060 m3/hr E1=18%, E2=57%, E3=75% 0.18 at 300FPM MERV 8

FC40R1003 20 in. x 20 in. 508 mm x 508 mm 1150 cfm 1950 m3/hr E1=31%, E2=61%, E3=86% 0.12 at 300FPM MERV 10

Controls
Water
FC40R1011 20 in. x 25 in. 508 mm x 635 mm 1450 cfm 2460 m3/hr E1=31%, E2=61%, E3=86% 0.12 at 300FPM MERV 10

FC40R1029 20 in. x 30 in. 508 mm x 762 mm 1800 cfm 3060 m3/hr E1=31%, E2=61%, E3=86% 0.12 at 300FPM MERV 10

FC40R1037 12 in. x 24 in. 305 mm x 610 mm 800 cfm 1360 m3/hr E1=31%, E2=61%, E3=86% 0.12 at 300FPM MERV 10

FC40R1045 14 in. x 25 in. 356 mm x 635 mm 1000 cfm 1700 m3/hr E1=31%, E2=61%, E3=86% 0.12 at 300FPM MERV 10

Building Automation
FC40R1052 16 in. x 20 in. 406 mm x 508 mm 900 cfm 1530 m3/hr E1=31%, E2=61%, E3=86% 0.12 at 300FPM MERV 10

FC40R1060 16 in. x 25 in. 406 mm x 635 mm 1150 cfm 1950 m3/hr E1=31%, E2=61%, E3=86% 0.12 at 300FPM MERV 10

FC40R1078 24 in. x 24 in. 610 mm x 610 mm 1700 cfm 2890 m3/hr E1=31%, E2=61%, E3=86% 0.12 at 300FPM MERV 10

FC40R1094 12 in. x 12 in. 305 mm x 305 mm 350 cfm 590 m3/hr E1=31%, E2=61%, E3=86% 0.12 at 300FPM MERV 10

FC40R1102 14 in. x 14 in. 356 mm x 356 mm 500 cfm 850 m3/hr E1=31%, E2=61%, E3=86% 0.12 at 300FPM MERV 10

FC40R1110 14 in. x 20 in. 356 mm x 508 mm 750 cfm 1270 m3/hr E1=31%, E2=61%, E3=86% 0.12 at 300FPM MERV 10

Components
Commercial
FC40R1128 14 in. x 24 in. 356 mm x 610 mm 950 cfm 1610 m3/hr E1=31%, E2=61%, E3=86% 0.12 at 300FPM MERV 10

FC40R1136 18 in. x 24 in. 457 mm x 610 mm 1250 cfm 2120 m3/hr E1=31%, E2=61%, E3=86% 0.12 at 300FPM MERV 10

FC40R1144 20 in. x 24 in. 508 mm x 610 mm 1400 cfm 2380 m3/hr E1=31%, E2=61%, E3=86% 0.12 at 300FPM MERV 10

FC40R1169 14 in. x 30 in. 356 mm x 762 mm 1200 cfm 2040 m3/hr E1=31%, E2=61%, E3=86% 0.12 at 300FPM MERV 10

FC40R1177 24 in. x 30 in. 610 mm x 762 mm 2050 cfm 3480 m3/hr E1=31%, E2=61%, E3=86% 0.12 at 300FPM MERV 10
Pneumatic Controls

FC40R1185 18 in. x 18 in. 457 mm x 457 mm 950 cfm 850 m3/hr E1=31%, E2=61%, E3=86% 0.12 at 300FPM MERV 10

FC40R1830 18 in. x 30 in. 457 mm x 762 mm 1550 cfm 2610 m3/hr E1=31%, E2=61%, E3=86% 0.12 at 300FPM MERV 10
Industrial Combustion
Controls

70-6910 71
Replacement Media Filters
Dimensions in inches (millimeters)

3/4
(19) B

A C

DIM D
E
DIMENSIONS IN. (MM)
Product
Numbers Size A B C D E
FC40R1003 20 X 20 (508 x 508) 19-3/4 (502) 19-3/4 (502) 18-1/2 (470) 18-1/2 (470) 4-3/8 (111)
FC40R1011 20 X 25 (508 x 635) 19-3/4 (502) 24-3/4 (629) 18-1/2 (470) 23-1/2 (597) 4-3/8 (111)
FC40R1029 20 X 30 (508 x 762) 19-3/4 (502) 29-3/4 (756) 18-1/2 (470) 28-1/2 (724) 4-3/8 (111)
FC40R1037 12 X 24 (305 X 610) 11-3/4 (298) 23-3/4 (603) 10-1/2 (266) 22-1/2 (571) 4-3/8 (111)
FC40R1045 14 X 25 (356 X 635) 13-3/4 (349) 24-3/4 (629) 12-1/2 (317) 23-1/2 (596) 4-3/8 (111)
FC40R1052 16 X 20 (406 X 508) 15-3/4 (400) 19-3/4 (502) 14-1/2 (368) 18-1/2 (470) 4-3/8 (111)
FC40R1060 16 X 25 (406 X 635) 15-3/4 (400) 24-3/4 (629) 14-1/2 (368) 23-1/2 (596) 4-3/8 (111)
FC40R1078 24 X 24 (610 X 610) 23-3/4 (603) 23-3/4 (603) 22-1/2 (571) 22-1/2 (571) 4-3/8 (111)
FC40R1094 12 X 12 (305 X 305) 11-3/4 (298) 11-3/4 (298) 10-1/2 (266) 10-1/2 (266) 4-3/8 (111)
FC40R1102 14 X 14 (356 X 356) 13-3/4 (349) 13-3/4 (349) 12-1/2 (317) 12-1/2 (317) 4-3/8 (111)
FC40R1110 14 X 20 (356 X 508) 13-3/4 (349) 19-3/4 (502) 10-1/2 (266) 18-1/2 (470) 4-3/8 (111)
FC40R1128 14 X 24 (356 x 610) 13-3/4 (349) 23-3/4 (603) 12-1/2 (317) 22-1/2 (571) 4-3/8 (111)
FC40R1136 18 X 24 (457 x 610) 17-3/4 (451) 23-3/4 (603) 16-1/2 (419) 22-1/2 (571) 4-3/8 (111)
FC40R1144 20 X 24 (508 x 610) 19-3/4 (502) 23-3/4 (603) 18-1/2 (470) 22-1/2 (571) 4-3/8 (111)
FC40R1169 14 X 30 (356 X 762) 13-3/4 (349) 29-3/4 (756) 12-1/2 (317) 28-1/2 (724) 4-3/8 (111)
FC40R1177 24 X 30 (610 X 762) 23-3/4 (603) 29-3/4 (756) 22-1/2 (571) 28-1/2 (724) 4-3/8 (111)
FC40R1185 18 X 18 (457 X 457) 17-3/4 (451) 17-3/4 (451) 16-1/2 (419) 16-1/2 (419) 4-3/8 (111)
FC40R1830 18 X 30 (457 X 762) 17-3/4 (451) 29-3/4 (756) 16-1/2 (419) 28-1/2 (724) 4-3/8 (111)
FC20R1625 16 X 25 (406 X 635) 15-3/4 (400) 24-3/4 (629) 14-1/2 (368) 23-1/2 (596) 2 (51)
FC20R2020 20 X 20 (508 x 508) 19-3/4 (502) 19-3/4 (502) 18-1/2 (470) 18-1/2 (470) 2 (51)
FC20R2025 20 X 25 (508 x 635) 19-3/4 (502) 24-3/4 (629) 18-1/2 (470) 23-1/2 (597) 2 (51)
FC20R2030 20 X 30 (508 x 762) 19-3/4 (502) 29-3/4 (756) 18-1/2 (470) 28-1/2 (724) 2 (51)
M 18953C

72 customer.honeywell.com 70-6910
Replacement Media Filters
Replacement Filter for Perfect Fit

Controls
Home
The replacement filter is a high-efficiency. long-life filter for Perfect
Fit media air cleaners. It captures a significant amount of airborne
particles in the air that circulates through the filter.
• Higher efficiency and lower pressure drop than OEM filter.
• Captures particles as small as 0.3 microns.
• Pleated filter for greater media capacity.
• Low pressure drop reduces strain on equipment, provides a

Indoor Air Quality


comfortable air flow, and helps maintain equipment efficiency.
• Easy installation. Angled edge fits neatly into offset side of air
cleaner frame.

Type of Air Cleaner: Media Air Cleaner


Application: Replacement Filter
Efficiency Standard: Efficiency ratings are based on American Society
of Heating, Refrigerating and Air-Conditioning Engineers Standard
52.2-1999.

Combustion Controls
Efficiency ranges are defined for small particles, E1=0.3 to 1.0 microns;

Residential
medium particles, E2=1.0 to 3.0 microns; and large particles, E3=3.0
to 10.0 microns.
Minimum Efficiency Reporting Value (Media Filters Only): MERV 10
Fractional Efficiency: E1=22%, E2=61%, E3=87%
Static Pressure Drop (in. w.c.): 0.17 at 500 FPM
Used WIth: Trane Perfect Fit Media Air Cleaners
Approvals:
Underwriters Laboratories, Inc. Filter Element: UL Listed, UL900,

Hydronic Controls
Class 2

Air Cleaner Size Dimensions, Approximate


Product Number (inch) (mm) Description
TRN1427T1 14 1/2 in. X 27 in. X 5 in. 360 mm x 670 mm x 120 mm 14 1/2 X 27 X 5 Replacement Filter for Perfect Fit. Replaces BAYFTFR14M.
TRN1727T1 17 1/2 in. X 27 in. X 5 in. 440 mm x 670 mm x 120 mm 17 1/2 X 27 X 5 Replacement Filter for Perfect Fit. REplaces BAYFTFR17M.
TRN2121T1 21 1/2 in. x 21 in. x 5 in. 540 mm x 510 mm x 120 mm 21 1/2 X 21 X 5 Replacement Filter for Perfect Fit. Replaces BAYFTAH21M.
TRN2127T1 21 in. x 27 in. x 5 in. 530 mm x 670 mm x 120 mm 21 X 27 X 5 Replacement Filter for Perfect Fit. Replaces BAYFTFR21M.

Controls
Water
TRN2321T1 23 1/2 in. x 21 in. x 5 in. 590 mm x 51 mm x 120 mm 23 1/2 X 21 X 5 Replacement Filter for Perfect Fit. Replaces BAYFTAH23M.
TRN2427T1 24 in. x 27 in. x 5 in. 620 mm x 670 mm x 120 mm 24 X 27 X 5 Replacement Filter for Perfect Fit. Replaces BAYFTFR24M.
TRN2621T1 26 in. X 21 in. X 5 in. 660 mm x 510 mm 120 mm 26 X 21 X 5 Replacement Filter for Perfect Fit. REplaces BAYFTAH26M.
Dimensions in inches (millimeters)

Building Automation
B

SIZE DIM A DIM B


INCHES (MM) INCHES (MM) INCHES (MM)

21-1/2 X 21 X 5 (546 X 533 X 127) 21.2 (538) 20.1 (511)

23-1/2 X 21 X 5 (597 X 533 X 127) 23.3 (592) 20.1 (511)

26 X 21 X 5 (660 X 533 X 127) 25.8 (655) 20.1 (511)

14-1/2 X 27 X 5 (368 X 686 X 127) 14.3 (363) 26.2 (665)

Components
Commercial
A
17-1/2 X 27 X 5 (445 X 686 X 127) 17.3 (439) 26.2 (665)

21 X 27 X 5 (533 X 686 X 127) 20.8 (528) 26.2 (665)

24 X 27 X 5 (610 X 686 X 127) 24.3 (617) 26.2 (665)

Pneumatic Controls

M28670A
4.9
(124)
Industrial Combustion
Controls

70-6910 73
Air Cleaner Parts and Accessories
Residential Air Cleaner Parts and Accessories
Product Number Description Used With
136414A Terminal Board Assembly, F50E. F50
136434AA 20 in. Replacement Ionizer wire for F50A, F50E, F50F, F57A, B, F58F and F70C —
136434BA 16 in. Replacement Ionizer wire for F50A, F50E, F50F, F59A —
136518 F50F, F58C,F Cell Key —
137266 F50F and F58F Cell Handle —
137980A Test Button Assembly for F50A, F50E, F50F, or F58C,F F50
138621A Contact Board Assembly, F50A F50
138889A Contact Board Assembly for F58C, F59A, F70C, F90, or F50E F50, F59
190912A F52C,D,E,F or F57A,B Contact Board Assembly F52
202668 20 inch Ionizer Grid —
203305AB F58F, F50F Door Assembly for 20 inch door, includes Test Button F50
203305AH 20 inch F100 Door F100
203306AB F50F Door Assembly, includes Test Button, 16 in F50
203306AH Door Assembly for 16 in. F100 F100
203321 ON/OFF Switch for F50F, F52F, or F58F F52
203329A F50F, F58F Rear Terminal Board Assembly F50
203329B F50F, F58F Front Terminal Board Assembly F50
203366 Round insulator for FC37A,B Cells FC37
203368 Prefilter for 16X25 - F50F, F300, no spring clips F300, F50
203369 Prefilter for 20X25 inch and 20X12-1/2 inch F50F, F300, no spring clip F300, F50
203370 Prefilter for 20X20 - F50F, F300, no spring clip F300, F50
203371 Prefilter for 16X25 - F50, F300 F300, F50
203372 Washable Prefilter for 20X25 inch and 20X12-1/2 inch F50, F300, or F58C,F F300, F50
203373 Prefilter for 20X20 - F50, F300 F300, F50
203638 Carbon Filter, Series 1,2,3 F59
207631 Door Latch, F52F F52
208536 Prefilter for F52F 1-Cell F52
208537 Prefilter for F52F 2-Cell F52
208543 interlock Switch, F52F F52
209989 Prefilter for 16X20 F50, F300 F300, F50
32004876-001 20 inch F200E Door, RF transmitter F200
32004876-002 16 inch F200E Door, RF transmitter F200
32004930-001 25 inch Power Pack Cover, White - F300E F300
32005012-001 HEPA Air Watch indicator F500
32006670-001 Blower Assembly for F500 F500
32007528-002 F300E Door Assembly, includes Test Button, 20 in F300
32007528-003 F300E Door Assembly, includes Test Button, 16 in F300
4074EHG FC37A Terminal Board Repair Kit. Contains 2 connector clips, 1 Terminal Board and instruction sheet —
4074ETD Line Cord and Strain Relief F50
4074ETE F50F, F52F, F58F Neon Light Assembly, includes lens and wire tie F50, F52
4074ETG F50F and F58F Interlock bracket and switch F50
4074ETH Air Flow Switch Bag Assembly, with pin connections, for F50 air cleaners F50
4074EYS F50F Neon Light Assembly F50
4074EZB Air Flow Switch Bag Assembly with molex plug connection. F300E, F50F, AFS F300, F50F

74 customer.honeywell.com 70-6910
Air Cleaner Parts and Accessories

Controls
Home
Product Number Description
FC37A1049 Electronic Air Cleaner Cell, 9.8 x 20

FC37A1064 Electronic Air Cleaner Cell, 12.4 x 20

Indoor Air Quality


FC37A1114 Electronic Air Cleaner Cell, 9.8 x 16

FC37A1130 Electronic Air Cleaner Cell, 12.4 x 16

FC37A1171 Electronic Air Cleaner Cell, 12.4 x 20

Combustion Controls
FC37B1030 Electronic Air Cleaner Cell, 12.4 x 20

Residential
W8600A,B AIRWATCH Indicator
Reminds you when to change your air filter, ultraviolet lamp and
humidifier pad.

Hydronic Controls
• Mounts in any convenient location.
• Easily mounted with two screws through holes in base.
• No wiring needed.
• Free with Honeywell Media Air Cleaner or sold separately for other
products.
• Indicator light flashes when batteries need changing. (CR-123
Lithium Battery available separately.)
• Indicator light flashes when media filter needs replacing or electronic
filter needs washing.
• Indicator light flashes when UV Air Treatment system lamp needs
replacing.
• Indicator light flashes when humidifier pad needs replacing.

Controls
Water
Application: Accessory

Product Number Description Used With


* W8600A1007 AIRWATCH indicator for use with F100F, F200 or F300A,E F300, F200, F50, F100, F150
W8600B1005 RF AIRWATCH indicator F200E F200

Building Automation
* TRADELINE models • SUPER TRADELINE models

Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 75
Air Cleaner Parts and Accessories
Residential Air Cleaners Replacement Power Supply
Product Number Description Used With
203365A Conversion Kit for changing 120V Power Supply to 240V. —
208045G F50F, F300 SSPS with W8600F capability and SSAFS. 120V 20X25, 16X25, 20X20, 20X12.5. F300, F50
208045J F50F, F300 SSPS with W8600F capability and SSAFS. 120V 16X20. F300, F50
208414A F50F SSPS with W8600E,F capability and SSAFS, 120V, 20X25. Replaces 203101A. Replaced by 208414H. F50
208414B F50F Power Supply Assembly F50F
208414C F50F SSPS with W8600E,F capability and SSAFS, 120V, 20X12.5. Replaces 203101C. F50
208416L F52E SSPS, 120V, 20X12.5. F52
208417Q F58F, F50F 120V 60 Hz Solid State Power Supply Assembly with W8600E,F capability and SSAFS (Replaces 203314A) F50
208417R F300E Power Box Assembly, SSPS with W8600F capability and SSAFS. 120V, 20X25. F300
208417S F300E Power Box Assembly, SSPS with W8600F capability and SSAFS. 120V, 16X25. F300
208418F F50F Power Box Assembly, SSPS with W8600E,F capability and SSAFS. 120V, 20X20. Replaces 203315A. F50
208418G F50F Power Box Assembly, SSPS with W8600E,F capability and SSAFS. 120V, 16X20. Replaces 203315F. F50
208418H F300E Power Box Assembly, SSPS with W8600F capability and SSAFS. 120V, 20X20. F300
208418J F300E Power Box Assembly, SSPS with W8600F capability and SSAFS. 120V, 16X20. F300
208419D F50F Power Box Assembly, SSPS with W8600E,F capability and SSAFS. 120V, 20X12.5. F50
208420A F50E Power Box Assembly, SSPS with W8600E,F capability and SSAFS, 120V, 16X25, 20X20, 20X25. Replaces F50
202228A AND 202228B.
208420B F50E Power Box Assembly, SSPS with W8600E,F capability and SSAFS, 2400V, 16X25, 20X20, 20X25. Replaces F50
202228C AND 202228D.
208421C F50F Power Box Assembly F50F
208422A F50A,E Power Box Assembly, SSPS with W8600E,F capability and SSAFS. 120V, 20X12.5. Replaces 203247A. F50
208422B F50A,E Power Box Assembly, SSPS with W8600E,F capability and SSAFS. 240V, 20X12.5. Replaces 203247B. F50
208425A EAC Power Supply for F50A, E F50
208425G F50A,E, F52C,D, F58A,E SSPS. 120V, 20X12.5. REPLACES 220429QXB, 220429AXB, 220429BXB. F50
208427AA F52F SSPS with W8600E,F capability and SSAFS. 120V, 20X25. Replaces 203327H. —
208427AB F50E SSPS with W8600E,F capability. 120V, 20X25, 16X25. F50
208427B F50E SSPS. 120V, 20X25 (Replaces 203327A) F50
208427C 120V Power Supply with Led and SSPI (Replaces 203361A) —
208427D Power Supply with Led and SSPI (Replaces 203361E) —
208427F F50E SSPS. 120V, 16X25, 20X20. Replaces 203327F. F50
208427H F52E SSPS. 120V, 20X12.5. Replaces 203350A. —
208427J F52F SSPS with W8600E capability. 120V, 20X12.5 (Replaces 203327R) —

76 customer.honeywell.com 70-6910
TrueDRY Dehumidification System
TrueDRY Dehumidification Systems

Controls
Home
TrueDRY Dehumidification Systems are integrated, which means
they’re more effective and can be less expensive than putting
multiple single-room units in a home. Plus, TrueDRY can be
installed “out of sight/out of mind” in the central heating and
cooling system to provide dehumidification to all rooms in the
home.

Indoor Air Quality


TrueDRY can also be used as a standalone solution to quietly
remove moisture from specific problem areas, improve comfort
and eliminate the need for maintenance (such as emptying
collection buckets) — all while using less energy compared to
most portable dehumidifiers.
The Honeywell TrueDRY ensures the home is maintained at proper
humidity levels through its high performance and efficiency.
• Removes up to 65, 90 or 150 pints of water per day from the indoor
air.

Combustion Controls
• Built-in fresh air supply

Residential
Application: Dehumidifier Voltage: 120 V
Color: White Electrical Ratings: 6.9 A

Capacity Plenum Opening (Diameter)


Weight
Product Number (pints per day) (gal. per day) (liter per day) (inch) (mm) Description (lb)
DH150A100 150 pints per day 18 3/4 gal per day 70 L per day 10 in. collars; 254 mm collars; TrueDRY 150-pint dehumidifier. 134 lb

Hydronic Controls
6 in. ventilation 152 mm vent No control included.
collar collar
DH150A105 150 pints per day 19 3/4 gal per day 70 L per day 10 in. collars; 254 mm collars; TrueDRY 150-pint dehumidifier 134 lb
6 in. ventilation 152 mm vent with VisionPRO IAQ control
collar collar
DR65A1000 65 pints per day 8 3/25 gal per day 30 L per day 8 in. collars 203 mm collar TrueDRY R-420A 65-pint —
dehumidifier with no control
DR65VPIAQ 65 pints per day 8 3/25 gal per day 30 L per day 8 in. collars 203 mm collar TrueDRY R-410A 65-pint —
dehumidifier with VisionPRO
IAQ control.

Controls
DR90A1000 90 pints per day 11 1/4 gal per day 45 L per day 10 in. collars; 254 mm collars; TrueDRY 90-pint dehumidifier 92.lb

Water
6 in. ventilation 152 mm vent with no control.
collar collar
DR90VPIAQ 90 pints per day 11 1/4 gal per day 45 L per day 10 in. collars; 254 mm collars; TrueDRY 90-pint dehumidifier 92lb
6 in. ventilation 152 mm vent with VisionPRO IAQ control.
collar collar

Building Automation
TrueDRY Parts and Accessories
Product Number Application Description Used With
50035445-001 Replacement Part DH150 enclosure DH150
50035445-002 Replacement Part DH150 heat exchanger DH150
50035445-003 Replacement Part DH150 capillary tubes DH150
50035445-004 Replacement Part DH150 compressor DH150

Components
Commercial
50035445-005 Replacement Part DH150 accumulator DH150
50035445-006 Replacement Part DH150 filter/drier DH150
50035445-007 Replacement Part DH150 tube -cond to filter DH150
50035445-008 Replacement Part DH150 tube -discharge line DH150
50035445-009 Replacement Part DH150 condenser DH150
Pneumatic Controls

50035445-010 Replacement Part DH150 impeller DH150


50035445-012 Replacement Part DH150 45 MFD capacitor -compressor DH150
50035445-015 Replacement Part DH150 15 MFD capacitor-impeller DH150
50035445-016 Replacement Part DH150 collar 10 inch DH150
50035445-017 Replacement Part DH150 collar oval 10 inch DH150
50035445-018 Replacement Part DH150 collar w/damper 6 inch DH150
Industrial Combustion

50035445-019 Replacement Part DH150 leveling foot DH150


50035445-020 Replacement Part DH150 MERV 11 filter DH150
Controls

50049537-001 Replacement Part Compressor overload DR65

70-6910 77
TrueDRY Dehumidification System
Product Number Application Description Used With
50049537-002 Replacement Part Compressor relay, DPDT 24 VAC, 30A DR65
50049537-003 Replacement Part Run capacitor, 35 MFD DR65
50049537-004 Replacement Part 8 in. Duct Collar DR65
50049537-005 Replacement Part Filter DR65
50035445-011 Replacement Part DR90 transformer 120/24 Vac, 40 VA DR90
50035445-014 Replacement Part DR90 compressor relay, SPST, 24 Vac, 30A DR90
50049536-001 Replacement Part DR90 compressor run capacitor DR90
50049536-003 Replacement Part DR90 Filter DR90
50049536-004 Replacement Part DR90 6 in. duct collar DR90
50049536-005 Replacement Part DR90 10 in. duct collar DR90
50049536-006 Replacement Part DR90 magnetic door DR90

78 customer.honeywell.com 70-6910
TrueSTEAM Humidification System
TrueSTEAM Humidification System

Controls
Home
Steam provides the highest and most consistent levels of
humidity.
• Application flexibility - Mount directly to the duct or remotely up to 20
feet away into tight-fitting or unconditioned air spaces.
• Installs in minutes - Limited duct cutting and bracket-mount design
takes less than 5 minutes to complete.
• Easy maintenance - Self-regulates cleaning cycles throughout the

Indoor Air Quality


year. Annual maintenance requires no tools to access and clean,
saving time and money on annual contractor service calls.
• 5-year warranty

Application: Humidification
Type: Steam
Dimensions, Approximate: 19 in. high x 11 1/4 in. wide x 9 in. deep
(482.6 mm H x 285.75 mm L x 228.6 mm D)
Mounting: Duct or Remote Mount (up to 20 feet/6 meters)

Combustion Controls
Temperature Range: 34 F to 104 F (1.1C-40C)

Residential
Voltage: 120 Vac
Color: Dark Empire Gray

Capacity Plenum Opening


Product Number gal. per day liter per day (inch) (mm) Description Includes
HM506DG115 6 gal per day 23 L per day 1 3/4 in. 44.45 mm TrueSTEAM 6-gallon Humidifier, TrueIAQ digital control, duct template hardware,

Hydronic Controls
diameter diameter with TrueIAQ control. saddle valve, drain supply water tubing, duct nozzle,
mounting bracket, water filter, backflow valve.
HM506H8908 6 gal per day 23 L per day 1 3/4 in. 44.45 mm TrueSTEAM 6-gallon Humidifier, H8908 manual humidistat, duct template
diameter diameter with H8908 control. hardware, saddle valve, drain supply water tubing, duct
nozzle, mounting bracket, water filter, backflow valve.
HM506VPIAQ 6 gal per day 23 L per day 1 3/4 in. 44.45 mm TrueSTEAM 6-gallon Humidifier, VisionPRO IAQ control, duct template hardware,
diameter diameter with VisionPRO IAQ saddle valve, drain supply water tubing, duct nozzle,
control. mounting bracket, water filter, backflow valve.
HM506W1005 6 gal per day 23 L per day 1 3/4 in. 44.45 mm TrueSTEAM 6-gallon Humidifier, duct template hardware, saddle valve, drain
diameter diameter model. Does not supply water tubing, duct nozzle, mounting bracket, water
include control. filter, backflow valve. Does not include humidistat.

Controls
Water
HM509DG115 9 gal per day 34 L per day 1 3/4 in. 44.45 mm TrueSTEAM 9-gallon Humidifier, TrueIAQ digital control, duct template hardware,
diameter diameter with TrueIAQ control. saddle valve, drain supply water tubing, duct nozzle,
mounting bracket, water filter, backflow valve.
HM509H8908 9 gal per day 34 L per day 1 3/4 in. 44.45 mm TrueSTEAM 9-gallon Humidifier, H8908 manual humidistat, duct template
diameter diameter with H8908 control. hardware, saddle valve, drain supply water tubing, duct
nozzle, mounting bracket, water filter, backflow valve.

Building Automation
HM509VPIAQ 9 gal per day 34 L per day 1 3/4 in. 44.45 mm TrueSTEAM 9-gallon Humidifier, VisionPRO IAQ control, duct template hardware,
diameter diameter with VisionPRO IAQ saddle valve, drain supply water tubing, duct nozzle,
control. mounting bracket, water filter, backflow valve.
HM509W1005 9 gal per day 34 L per day 1 3/4 in. 44.45 mm TrueSTEAM 9-gallon Humidifier, duct template hardware, saddle valve, drain
diameter diameter model. Does not supply water tubing, duct nozzle, mounting bracket, water
include control. filter, backflow valve. Does not include humidistat.
HM512DG115 12 gal per day 46 L per day 1 3/4 in. 44.45 mm TrueSTEAM 12-gallon Humidifier, TrueIAQ digital control, duct template hardware,
diameter diameter with TrueIAQ control. saddle valve, drain supply water tubing, duct nozzle,
mounting bracket, water filter, backflow valve.
HM512VPIAQ 12 gal per day 46 L per day 1 3/4 in. 44.45 mm TrueSTEAM 12-gallon Humidifier, VisionPRO IAQ control, duct template hardware,

Components
Commercial
diameter diameter with VisionPRO IAQ saddle valve, drain supply water tubing, duct nozzle,
control. mounting bracket, water filter, backflow valve.
HM512W1005 12 gal per day 46 L per day 1 3/4 in. 44.45 mm Wireless TrueSTEAM Humidifier, duct template hardware, saddle valve, drain
diameter diameter 12-gallon model. supply water tubing, duct nozzle, mounting bracket, water
filter, backflow valve. Does not include humidistat.
HM512WTHX9 12 gal per day 46 L per day 1 3/4 in. 44.45 mm TrueSTEAM 12-gallon Humidifier, Prestige control, duct template hardware, saddle
diameter diameter model with Prestige valve, drain supply water tubing, duct nozzle, mounting
Pneumatic Controls

HD control and bracket, water filter, backflow valve.


RedLINK wireless
adaptor.

TrueSTEAM Installation Accessories


Product Number Description
Industrial Combustion

50024917-001 TrueSTEAM 10-Foot Remote Mount Kit. Compatible with all TrueSTEAM models.
50024917-002 TrueSTEAM 20-Foot Remote Mount Kit. Compatible with HM512 and HM509 TrueSTEAM models.
Controls

50027910-001 Duct or Remote Mount Differential Pressure Switch

70-6910 79
TrueIAQ Control
TrueIAQ® Automatic Digital IAQ Control
Integrate control of you home's humidification, dehumidification,
ventilation and even bathroom fans into a single device with
Honeywell's TrueIAQ control. TrueIAQ allows you to program your
air quality and fan settings individually, or as a system for
increased comfort and energy savings. Plus, TrueIAQ will
automatically adjust settings for changes in outside temperature
and humidity, and provides maintenance reminders to help keep
your equipment operating at peak efficiency. For true indoor air
quality control, choose TrueIAQ.
• Setting changes can be made easily with the touch of a button.
• Manages humidification, dehumidification, ventilation and bathroom
fans from a central point in your home.
• Simultaneously displays both indoor and outdoor temperature and
humidity levels on-screen. Automatically adjusts inside settings
based on outdoor conditions.
• Include individual air quality enhancements to your system with
TrueIAQ®, or integrate them all as part of a total air quality system.
• Intuitive digital backlit display.

Application: Provides humidity control for ducts, greenhouses, Dimensions, Approximate: 19 in. high x 11 1/4 in. wide x 9 in. deep
computer rooms, printing and photographic laboratories, and other Mounting: Duct or Remote Mount (up to 20 feet)
applications where electronic accuracy, as well as remote sensing, is Temperature Range: (1.1C-40C)
desired. Voltage: 120 Vac
Type: Steam Color: White

Electrical Ratings Operating Humidity


Product Number (120 Vac, Full Load) Range (% RH) Description Includes Used With
DG115EZIAQ 2.0A at 24 Vac, humidifier, 95% RH at 95 F, Digital control for TrueIAQ control and outdoor sensor Outdoor temp/humidity
dehumidifier, vent contacts non-condensing IAQ equipment for temperature and humidity sensor (included)

80 customer.honeywell.com 70-6910
Bypass Humidifiers
HE225; HE265 Bypass Flow-through Humidifier

Controls
Home
Bypass Flow-through Humidifiers use the warm air furnace blower
to provide whole house humidification.
• Humidifier pad is coated with AGION antimicrobial agent.
• Pre-assembled for quicker installation.
• Small footprint, light weight and reversible components allow for
easy mounting on either warm air supply or cold air return of any
forced air furnace.

Indoor Air Quality


• Interior components designed for quick maintenance and service.
• Option of automatic humidity control or standard humidistat.
• Standard tested per ARI Standard 610.

Application: Humidification
Type: Bypass Flow-Through
Mounting: Duct mount
Voltage: 24 Vac
Frequency: 60 Hz

Combustion Controls
Electrical Ratings: 0.5A

Residential
Color: White and Blue
Approvals:
Underwriters Laboratories, Inc. UL/cUL Listed Report E185662

Capacity Plenum Opening

Hydronic Controls
Product Number gal. per day liter per day (inch) (mm) Description Includes
HE225A1014 12 gal per day 46 L per day 9 7/16 in. high x 241 mm high x Bypass flow-through Humidifier, summer shut-off damper
9 5/18 in. wide 238 mm wide humidifier with humidifier pad, mounting template, self-
H8908 control. piercing saddle valve 24 Vac transformer
Includes installation and wire, standard humidistat and bypass
hardware. installation materials.
HE225B1234 12 gal per day 46 L per day 9 7/16 in. high x 241 mm high x Bypass Flow Humidifier, summer shut-off damper
9 5/18 in. wide 238 mm wide Through Humidifier humidifier pad, mounting template, self-
with TrueIAQ Control. piercing saddle valve 24 Vac transformer
Includes installation and wire, automatic humidistat, and
hardware. bypass installation materials

Controls
Water
* HE225DG115 12 gal per day 46 L per day 9 7/16 in. high x 241 mm high x Bypass flow-through Humidifier, summer shut-off damper
9 5/18 in. wide 238 mm wide humidifier with humidifier pad, mounting template, self-
TrueIAQ digital piercing saddle valve 24 Vac transformer
control. and wire, automatic humidistat
* HE225VPIAQ 12 gal per day 46 L per day 9 7/16 in. high x 241 mm high x Bypass flow-through Humidifier, summer shut-off damper
9 5/18 in. wide 238 mm wide humidifier with humidifier pad, mounting template, self-
VisionPRO IAQ piercing saddle valve 24 Vac transformer

Building Automation
and wire, automatic humidistat
HE265A1234 17 gal per day 64 L per day 12 5/8 in. high x 321 mm high x Bypass Flow Humidifier, summer shut-off damper
9 3/4 in. wide 248 mm wide Through Humidifier humidifier pad, mounting template, self-
with H8908 piercing saddle valve 24 Vac transformer
Humidistat. Includes and wire, standard humidistat, and bypass
installation hardware. installation materials
HE265B1234 17 gal per day 64 L per day 12 5/8 in. high x 321 mm high x Bypass Flow Humidifier, summer shut-off damper
9 3/4 in. wide 248 mm wide Through Humidifier humidifier pad, mounting template, self-
with TrueIAQ Control. piercing saddle valve 24 Vac transformer
Includes installation and wire, automatic humidistat, and

Components
Commercial
hardware. bypass installation materials
* HE265DG115 17 gal per day 64 L per day 12 5/8 in. high x 321 mm high x Bypass flow-through Humidifier, summer shut-off damper
9 3/4 in. wide 248 mm wide humidifier with humidifier pad, mounting template, self-
TrueIAQ digital piercing saddle valve 24 Vac transformer
control. and wire, automatic humidistat
* HE265H8908 17 gal per day 64 L per day 12 5/8 in. high x 321 mm high x Bypass flow-through Humidifier, summer shut-off damper
9 3/4 in. wide 248 mm wide humidifier with humidifier pad, mounting template, self-
H8908A humidistat. piercing saddle valve 24 Vac transformer
Pneumatic Controls

and wire, standard humidistat


* HE265VPIAQ 17 gal per day 64 L per day 12 5/8 in. high x 321 mm high x Bypass flow-through Humidifier, summer shut-off damper
9 3/4 in. wide 248 mm wide humidifier with humidifier pad, mounting template, self-
VisionPRO IAQ piercing saddle valve 24 Vac transformer
and wire, automatic humidistat
* TRADELINE models • SUPER TRADELINE models
Industrial Combustion
Controls

70-6910 81
Bypass Humidifiers
HE225 Dimensions in inches (millimeters) HE265 Dimensions in inches (millimeters)

2) 5)
(23 (23
/8 /4
9-1 11
-7 9-1 12
/16 (30
(29 5)
0)

13
12 -9/
(30 16
5) (34
5)

12 15
-7 -5
(3 /16 (3 /16
16 90
) )

HE225
HE265
16 -3/
4
-9/ 16 5)
13 45)
(3 6 (152) (42 6 (152)
DIAMETER DIAMETER

M23244 M23245

82 customer.honeywell.com 70-6910
Bypass Humidifiers
HE225 and HE265 Exploded View

Controls
Home
4

Indoor Air Quality


9 1
8

Combustion Controls
6

Residential
10
2

Hydronic Controls
11
3

Controls
Water
8

Building Automation
1 THE HE225H OR HE265H INCLUDES
THE H8908 CONVERTIBLE HUMIDITY
CONTROL.
2 THE HE225D OR HE265D INCLUDES
8

Components
THE TrueIAQ.

Commercial
3 THE HE225V AND HE265V INCLUDES THE
VisionPRO IAQ.

HE225 Part HE265 Part


No. Description Number Number
4 PerfectFlo™ water distribution tray 32001619-001 32001630-001
5 Humidifier Pad (pad has antimicrobial coating) HC22E1003 HC26E1004
Pneumatic Controls

6 Humidifier Pad Frame 32001621-001 32001632-001


7 Drain fitting 32001615-001 32001615-001
8 Solenoid valve assembly (includes nozzle) 32001639-002 32001639-002
9 H8908 Humidity Control H8908ASPST H8908ASPST
10 TrueIAQ Digital Automatic Control with Outdoor Enthalpy DG115EZIAQ DG115EZIAQ
Sensor
11 VisionPRO IAQ with outdoor temp sensor YTH9421C1010 YTH9421C1010
— Hardware Kit for Solenoid Assembly (same as Solenoid valve 32001752-001 32001752-001
Industrial Combustion

assembly without the solenoid valve)


— Current Sensing Relay 32001754-001 32001754-001
M23213A
Controls

70-6910 83
Fan Humidifiers
HE365 Fan Flow-through Humidifier
Fan-powered flow-through humidifier uses the warm air furnace
blower to provide whole house humidification.
• Humidifier pad is coated with AGION antimicrobial agent.
• Capable of humidifying large areas, up to 3,000 sq. ft.
• Interior components designed for quick maintenance and service.
• Option of automatic humidity control or standard humidistat.
• Standard tested per ARI Standard 610.

Dimensions in inches (millimeters) Application: Humidification


Type: Fan Powered Flow-Through
Dimensions, Approximate: 15 in. high x 14 in. wide x 10 1/4 in. deep
0) (387 mm high x 356 mm wide x 260 mm deep)
(26
1/4
10- 14
(35 Mounting: Duct mount
6)
Voltage: 120 Vac
Frequency: 60 Hz
Electrical Ratings: 0.7 A
Color: White and Blue
Approvals:
Underwriters Laboratories, Inc. UL/cUL Listed Report E185662

15
-1
(38 /4
7)

M14815

Capacity Plenum Opening


Product Number gal. per day liter per day (inch) (mm) Description Includes
HE365A1234 18 gal per day 68 L per day 14 1/16 in. high x 357 mm high x Fan-powered flow-through Humidifier, mounting template,
13 1/2 in. wide 343 mm wide humidifier with H8908 humidifier pad, self-piercing saddle
Humidistat. Includes valve, standard humidistat, and
installation hardware. installation materials
HE365B1234 18 gal per day 68 L per day 14 1/16 in. high x 357 mm high x Fan-powered flow-through Humidifier, mounting template,
13 1/2 in. wide 343 mm wide humidifier with TrueIAQ humidifier pad, self-piercing saddle
digital control. Includes valve, automatic humidistat, and
installation hardware. installation materials
* HE365DG115 18 gal per day 68 L per day 14 1/16 in. high x 357 mm high x Fan-powered flow-through Humidifier, mounting template,
13 1/2 in. wide 343 mm wide humidifier with TrueIAQ humidifier pad, self-piercing saddle
digital control valve, automatic humidistat.
* HE365H8908 18 gal per day 68 L per day 14 1/16 in. high x 357 mm high x Fan-powered flow-through Humidifier, mounting template,
13 1/2 in. wide 343 mm wide humidifier with H8908 humidifier pad, self-piercing saddle
Humidistat valve, standard Humidistat.
HE365VPIAQ 18 gal per day 68 L per day 14 1/16 in. high x 357 mm high x Fan-powered flow-through Humidifier, mounting template,
13 1/2 in. wide 343 mm wide humidifier with VisionPRO humidifier pad, self-piercing saddle
IAQ control valve, standard Humidistat.
* TRADELINE models • SUPER TRADELINE models

84 customer.honeywell.com 70-6910
Fan Humidifiers
HE365 Exploded View

Controls
Home
3

Indoor Air Quality


4

7
1

Combustion Controls
8

Residential
2
9

Hydronic Controls
3

Controls
Water
Building Automation
5

1 THE HE365H INCLUDES THE H8908 CONVERTIBLE HUMIDITY CONTROL.

Components
Commercial
2 THE HE365D INCLUDES THE TrueIAQ AUTOMATIC HUMIDITY CONTROL.

3 THE HE365V INCLUDES THE VisionPRO IAQ.

No. Description HE365 Part Number


2 Water Distribution Tray 32001630-001
3 Solenoid Valve Assembly (includes nozzle) 32001876-001
Pneumatic Controls

4 Humidifier Pad (pad has antimicrobial coating) HC26E1004


5 PWB Assembly (includes transformer) 32001676-001
6 Humidifier Pad Frame 32001632-001
7 H8908 Humidity Control H8908ASPST
8 TrueIAQ Automatic Humidity Control DG115EZIAQ
9 VisionPRO IAQ with Outdoor Temp Sensor YTH9421C1010
10 Drain Fitting 32001615-001
Not Hardware Kit for Solenoid Assembly 32001752-001
Industrial Combustion

shown (same as Solenoid Valve Assembly without the solenoid valve)


— Current Sensing Relay 32001754-001
Controls

M23214A

70-6910 85
Humidifier Replacement Pads and Filters
Humidifier Replacement Pads and Filters
Type: Humidifier Replacement Pad
Application: Replacement Pads and Filters

Product Number Description Includes Used With


32000146-001 HE120 Replacement Humidifier — HE120
Pad (includes clips)
50028044-001 Plumb in-line scale and sediment 1 filter All Honeywell steam and evaporative humidifiers. Also
filter with quick-connect fittings. fits AprilAire evaporative models.
* HC22A1007 HE220 Humidifier Pad Standard Humidifier Pad Honeywell HE220, HE225, Aprilaire Models 110, 220,
550, 558
* HC22E1003 HE225 Humidifier Pad with AgION Antimicrobial Humidifier Pad Honeywell HE220, HE225, Aprilaire Models 110, 220,
AgION™ Coating 550, 558
* HC26A1008 HE260 Humidifier Pad Standard Humidifier Pad Honeywell HE260, HE265, HE360, HE365, Aprilaire 350,
360, 560, 568, 600, 700, 760, 768
* HC26E1004 HE265 Humidifier Pad with AgION Antimicrobial Humidifier Pad Honeywell HE260, HE265, HE360, HE365, Aprilaire 350,
AgION™ Coating 360, 560, 568, 600, 700, 760, 769
* TRADELINE models • SUPER TRADELINE models

Humidifier Parts
Product Number Description Used With
32000132-001 HE120 24 Vac Motor HE120
32000136-001 HE120 Float Valve HE120
32000149-001 HE420 Safety Float Switch HE420
32000156-001 HE420 Fan Wiring Assembly HE420
32000159-001 HE420 Thermal Fan Switch HE420
32000164-001 HE420 Heating Element HE420
32000166-001 HE420 Float for Water Fill Valve HE420
32000167-001 HE420 Water Fill Valve HE420
32000408-001 HE360, HE365 Feed Tube Nozzle HE360, HE365
32000429-001 HE360, HE365 Fan Blade HE360, HE365
32001615-001 HE220, HE225, HE260, HE265, HE360, HE365 Drain Fitting HE220, HE225, HE260, HE265,
HE360, HE365
32001616-001 HE120, HE220, HE225, HE260, HE265, HE360, HE365 Saddle Valve Assembly HE120, HE220, HE225, HE260,
HE265, HE360, HE365
32001619-001 HE220, HE225, HE360A1001 PerfectFlo™ Water Distribution Tray HE220, HE225, HE360
32001621-001 HE220, HE225 Humidifier Pad Frame HE220, HE225
32001630-001 HE260, HE265, HE360, HE365 PerfectFlo™ Water Distribution Tray HE260, HE265, HE360, HE365
32001632-001 HE260, HE265, HE360, HE365 Humidifier Pad Frame HE260, HE265, HE360, HE365
32001639-002 HE220, HE225, HE260, HE265 Solenoid Valve Assembly (includes water feed tube and nozzle) HE220, HE225, HE260, HE265
32001652-001 HE220, HE225, HE260, HE265 Transformer (10VA) HE260, HE265, HE360, HE365
32001676-001 HE360, HE365 Printed Wiring Board Assembly HE360, HE365

86 customer.honeywell.com 70-6910
Humidifier Replacement Pads and Filters

Controls
Product Number Description Used With

Home
32001676-001 HE360, HE365 Printed Wiring Board Assembly HE360, HE365
32001752-001 HE220, HE225, HE260, HE265, HE360, HE365 Hardware Kit for Solenoid Assembly (does not include HE220, HE225, HE260, HE265,
solenoid valve) HE360, HE365
32001754-001 Current Sensing Relay HE220, HE225, HE260, HE265,
HE360, HE365

Indoor Air Quality


32001876-001 HE360, HE365 Solenoid Valve Assembly (includes water feed tube) HE360, HE365
32006450-001 HE440 Filter Pack HE440
32006451-001 HE440 Chlorine Filter HE440
50000240-001 Seasonal damper for bypass humidifier HE225, HE265
50018841-001 Mounting Bracket for HE420 HE420
50018842-001 Auto Flush Timer for the HE420 HE420

Combustion Controls
50018844-001 DPST 24V Control Relay for HE420 HE420

Residential
50018846-001 Safety Control Shut off for the HE420 HE420
50018847-001 SPDT Relay for HE420 HE420
50019240-001 In-line Chlorine Filter used with a HE420 HE420
50020012-001 Mounting Bracket for TrueSTEAM —
50027997-001 Solenoid Valve for TrueSTEAM —
50027998-001 Water Level Sensor Assembly for TrueSTEAM —

Hydronic Controls
50028001-001 Remote-Mount Nozzles for TrueSTEAM —
50028003-001 TrueSTEAM Duct Nozzle —
50028004-001 TrueSTEAM Cover —
50030142-001 Backflow Prevention Valve for TrueSTEAM —
50033181-001 Large water Tank for TrueSTEAM HM509 and HM512 —
50033182-001 Small Water Tank for TrueSTEAM HM506 —

Controls
Water
Building Automation
Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 87
Humidity Controllers
H46 Humidity Controller
Provide automatic control of a humidifier or dehumidifier for
dehumidification in air conditioning systems.
• Positive ON-OFF settings permit manual operation of controlled
equipment.
• Impact-resistant, molded plastic cover mounts on wall.
• Fully enclosed, dust free, SPST, snap-acting switch.
• Sensing element of thin, moisture sensitive nylon ribbon provides
reliable operation even when ambient temperature conditions
change.

Type: Humidity Control


Dimensions, Approximate:
4 11/16 in. high x 2 15/16 in. wide x 2 1/8 in. deep
(119 mm high x 75 mm wide x 54 mm deep)
Mounting: Wall mount
Temperature Range: 50 F to 125 F (10 C to 52 C)
Differential: 4% to 6% RH
Voltage: 24 Vac; 120 Vac 240 Vac

Electrical Ratings
Operating 120 Vac 240 Vac
Humidity
Range Full Locked Full Locked
Product Number Application (% RH) Load Rotor Resistive Load Rotor Resistive Color Description
* H46C1166 Dehumidification 20 to 80% 7.5A 30.0A 6.0A 3.8A 15.0A 6.0A Premier Wall mounted
RH White® Dehumidistat
* H46D1214 Humidification 10 to 60% 4.4A 26.4A 6.0A 2.2A 13.2A 6.0A Premier Wall mounted Humidistat
RH White®
* H46E1013 Dehumidification 20 to 80% 7.5A 30.0A 6.0A 3.8A 15.0A 6.0A Beige Dehumidistat with plug for
RH window Air Conditioner or
portable dehumidifier
* TRADELINE models • SUPER TRADELINE models

H600 Humidity Controllers


Operates humidification equipment on RH fall or dehumidification
equipment on RH rise.
• Sensing element of thin, moisture sensitive nylon ribbon provides
reliable operation even when ambient temperature conditions
change.
• Fully enclosed, dust free, SPDT, snap-acting switch.
• Removable setting knob prevents tampering.
• Mount vertically on 2 x 4 in. junction box (not to be duct mounted).
• Includes alternate scale and faceplate for horizontal mounting.

Application: Humidification or Dehumidification


Type: Humidity Control
Dimensions, Approximate:
6 3/16 in. high x 3 3/8 in. wide x 2 1/4 in. deep
(157 mm high x 86 mm wide x 57 mm deep)
Mounting: Wall mount
Temperature Range: 50 F to 125 F (10 C to 52 C)
Differential: 5% RH
Voltage: 24 Vac; 120 Vac; 240 Vac
Color: Gray

Electrical Ratings
Operating 120 Vac 240 Vac
Humidity Range
Product Number (% RH) Full Load Locked Rotor Resistive Full Load Locked Rotor Resistive
* H600A1014 20 to 80% RH Dehumidifier Dehumidifier Dehumidifier Dehumidifier Dehumidifier Dehumidifier
Contacts 7.5A Contacts 30A Contacts 6 A Contacts 3.8A Contacts 15A Contacts 6 A
Humidifier Humidifier Humidifier Humidifier Humidifier Humidifier
Contacts 4.4 A Contacts 26.4 A Contacts 6 A Contacts 2.2 A Contacts 13.2 A Contacts 6 A
* TRADELINE models • SUPER TRADELINE models

88 customer.honeywell.com 70-6910
Humidity Controllers
H8908 Humidistat/Dehumidistat

Controls
Home
The H8908A Humidistat and H8908D Dehumidistat (humidity
controllers) provide automatic low voltage control of humidifiers
and dehumidifiers or ventilators, respectively, in central heating
and air conditioning systems. They have a SPST, snap-acting,
dust-proof switch and are designed for wall or surface duct
mounting.
• SPST, snap-acting, dust-proof switch and are designed for wall or

Indoor Air Quality


surface duct mounting.
• Positive ON and OFF settings.
• Twelve-inch ribbon of thin, moisture-sensitive nylon ribbon wound
around three bobbins effectively gives optimum control for reliable
operation under changing ambient conditions.
• Mounts in duct or on wall surface.

Type: Steam
Dimensions, Approximate: 19 in. high x 11 1/4 in. wide x 9 in. deep

Combustion Controls
(482.6 mm H x 285.75 mm L x 228.6 mm D)
Mounting: Duct or Remote Mount (up to 20 feet/6 meters)

Residential
Temperature Range: (1.1C-40C)
Voltage: 24 Vac

Product Number Application Color


H8908ASPST Provides humidity control for ducts, greenhouses, computer rooms, printing and photographic laboratories, and other White
applications where electronic accuracy, as well as remote sensing, is desired.

Hydronic Controls
H8908DSPST Provides humidity control for ducts, greenhouses, computer rooms, printing and photographic laboratories, and other White
applications where electronic accuracy, as well as remote sensing, is desired.
* TRADELINE models • SUPER TRADELINE models

Controls
Water
Building Automation
Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 89
Ultraviolet Air Treatment Systems
UV100 Ultraviolet Air Treatment Systems
Airborne pathogens can be circulated and spread in the airflow of
residential ductwork. The high intensity energy from Honeywell UV
air treatment system has been proven to kill up to 87% of certain
airborne bacteria passing by the lamp in a single pass.
• SnapLamp™ features replacement lamp handle with detachable
replacement bulb, UC18W or UC36W, to make replacement more
economical.
• UV-C light kills airborne bacteria or surface mold.
• Continuously emits ultraviolet energy.
• UV lamp does not produce ozone.
• Sealed unit design prevents accidental installer and homeowner
contact with the voltage and with the ultraviolet rays.
• Safe design prevents lamps from lighting unless the base is correctly
mounted on the HVAC duct.
• Lamp light indicator to safely view the lamp operation.
• Power cord that plugs into electrical outlet.
• Quick and easy bulb replacement.
• Easy lamp maintenance.
• Optional AIRWATCH™ Indicator can be installed to remind
customers when to change bulb.
• To capture and minimize micro-organism pass-through in residential
heating, ventilation and air conditioning (HVAC) systems, combine
the Ultraviolet System with a high-efficiency air filtration system that
includes an electronic air cleaner.

Operating Temperature (inside Duct): 30 F to 140 F (-2 C to +60 C)


Operating Temperature (outside Duct): 30 F to 104 F (-2 C to +40 C)
Replacement Parts:
UC10W1 Replacement Bulb for TrueUV Coil Treatment Systems
UC18W1004 Replacement Bulb for 18W Single Lamp Return Air
Models
UC36W1006 Replacement Bulb for 36W Dual Lamp Return Air Models
and Coil Irradiation Models

Electrical Ratings
Contaminants
Product Number Application Type Reduced (Vac) (Watts) Description
UV100A1059 Return Air or Coil Irradiation Airborne Bacteria, 120 Vac 36W Ultraviolet Surface Treatment or Air Treatment
Application Surface Mold System, Coil Plus Model
UV100A2008 Return Air or Coil Irradiation Airborne Bacteria, 240 Vac 36W Ultraviolet Surface Treatment or Air Treatment
Application Surface Mold System, Coil Plus Model, 240V
UV100E1043 Return Air Application Airborne Bacteria 120 Vac 18W SmartLamp Ultraviolet Air Treatment System,
Single Lamp Return Air Model
UV100E2009 Return Air Application Airborne Bacteria 120 Vac 36W each SmartLamp Ultraviolet Air Treatment System,
Dual Lamp Return Air Model
UV100E3007 Coil Irradiation Application Surface Mold 120 Vac 36W SmartLamp Ultraviolet Surface Treatment
System, Coil Irradiation Model
UV100RM1 Coil Irradiation Application Surface Mold 24 Vac/dc, 15 VA 10W Low voltage ultraviolet treatment system with
remote mount capability
Dimensions in inches (millimeters) for single bulb models Dimensions in inches (millimeters) for dual bulb models

5 (127) AIR TREATMENT SYSTEM


AIR TREATMENT SYSTEM 3-1/2
3-1/2 (SINGLE-LAMP) (89) (DUAL LAMP)
(89)

1
(25)
3-1/4
7 (83)
2-3/16
(178) (56)
8-1/2
(216)

2-1/4 4 (102) 7-7/16 (188)


(57)
3-1/2 M23238
(89) 4-1/2
(114)
7 (178) 3-1/2 (89) 14-7/8
4 (102)
5 (127) (379)
7 (178)
10 (254)
M23239

90 customer.honeywell.com 70-6910
Ultraviolet Air Treatment Systems
Dimensions in inches (millimeters) for long bulb models

Controls
Home
SURFACE TREATMENT
SYSTEM
3-1/2
(89)

Indoor Air Quality


(25)

7
(178)

2-1/4 4 (102) 14-7/8 (379)


(57)

Combustion Controls
3-1/2 (89)
4-1/2 (114) M23230

Residential
7 (178)

Dimensions in inches (millimeters) for low voltage models

1-11/32
16-11/16 (424) (34) 2-3/4 (74)
2-3/4 (70)
1-13/16
(47)
3-5/32

Hydronic Controls
(80)
1-1/2 (38)

4-3/32
14-61/64 (380) (104)

M27054

M27056

Controls
Water
Possible mounting locations for Ultraviolet Air Treatment Systems

CONDENSER
COOLING AIR

Building Automation
CONDITIONED AIR
TO ROOM

COIL IRRADIATION
UNIT LOCATION
REMOTE CONDENSER
RETURN SECTION (HIGH SIDE)
AIR CONDENSATE
DRAIN REFRIGERANT
SINGLE-LAMP
PIPING
AND DUAL-LAMP
UNIT LOCATION

Components
FURNACE

Commercial
HEAT
EXCHANGER

Pneumatic Controls

HIGH EFFICIENCY
AIR CLEANER M23240
Industrial Combustion
Controls

70-6910 91
Ultraviolet Air Treatment Systems
Replacement Lamp Ultraviolet Air Treatment System
The UC100 Ultraviolet Air Treatment System Replacement Lamp is
for use with the UV100 Ultraviolet Air Treatment System.

Electrical
Product Number Application Type Ratings (Watts) Description Used With
UC100A1005 Replacement Lamp 18W Replacement SnapLamp for UV100A1000, UV100A1000
brown handle
UC100A1054 Replacement Lamp 36W Replacement SnapLamp for UV100A1059 UV100A1018, UV100A1059
and UV100A2008, brown handle.
UC100E1006 Replacement Lamp 18W Replacement SnapLamp for UV100E1001 UV100E1001, UV100E1043
and UV100E1043, blue handle.
UC100E1030 Replacement Lamp 36W Replacement SnapLamp for UV100E3007, UV100A1018, UV100E3007, UV100E1035,
UV100E1035, UV100A1059 and UV100A2009, UV100A1059, UV100A2008
UV100A2008, blue handle.
UC10W1 Replacement Bulb 10W Replacement bulb for TrueUV UV100RM1
UC18W1004 Replacement Bulb 18W Replacement Bulb for 18W SnapLamp UC100A1005, UC100E1006, UV100A1000,
Models UV100E1043
UC36W1006 Replacement Bulb 36W Replacement Bulb for 36W SnapLamp UC100A1013, UC100A1054, UC100E1014,
Models UC100E1030, UV100A1018, UV100A1059,
UV100A2008, UV100E2009, UV100E3007

92 customer.honeywell.com 70-6910
Fresh Air Ventilation Systems
ER150; ER200 Energy Recovery Fresh Air Ventilation Systems

Controls
Home
Perfect Window® Fresh Air Energy Recovery Ventilation Systems
Energy Recovery Ventilators provide proper levels of ventilation
with energy savings by transferring heat and moisture between the
exhaust and fresh air streams.
• Includes heat/energy transfer core, pre-filters, and fan and blower
assembly.
• Provides ventilation that helps contractors meet ASHRAE 62-89.

Indoor Air Quality


• Electronic ventilation fan timer option.
• Low voltage, high-speed override.
• Variable fan speed control.
• Easy-to-clean with a vacuum, cross-flow enthalpic core assures
years of trouble-free operation.
• Insulated cabinet.
• Rugged steel cabinet.
• Quiet operation.
• Permanent (washable) pre-filters.

Combustion Controls
• Integral balancing dampers.
• Includes vibration isolation hardware and duct collars.

Residential
Application: Energy Recovery Ventilator Frequency: 60 Hz
Type of Core: Enthalpy cross flow core Moisture Transfer Ratio: 0.26
Electrical Ratings: 120 Vac Temperature Recovery: 0.79

Current Draw, Nominal


Airflow Capacity
(external static (maximum (minimum

Hydronic Controls
Product Number pressure) Characteristics speed) speed) Defrost Control
* ER150B2006 150 cfm (0.1 in. wc) Energy Recovery Ventilator 150 CFM 1.7 A 0.7 A Built-in Defrost
* ER150C2004 150 cfm (0.1 in. wc) Energy Recovery Ventilator 150 CFM, no defrost 1.7 A 0.7 A No Defrost
* ER200B2006 208 cfm (0.2 in. wc) Energy Recovery Ventilator 200 CFM 1.7 A 0.8 A Built-in Defrost
* ER200C2004 208 cfm (0.2 in. wc) Energy Recovery Ventilator 200 CFM, no defrost 1.7 A 0.8 A No Defrost
* TRADELINE models • SUPER TRADELINE models

Controls
Water
Building Automation
Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 93
Fresh Air Ventilation Systems
ER150 and ER200 Exploded View and Replacement parts

11
13
12

9
6

10

14

Part Number for


No. Description ER150 or ER200
1 Cross-Flow Enthalpy Core, with Guide Channels 32002074-001
2 Blower Motor 208359
3 Blower Housing Kit 50002341-001
4 Motor Capacitor 209711
5 Foam Prefilter, Set of two 32002114-001
6 Clip for Foam Prefilter 209722
7 Drain Spout 208514
8 Door Latch, Complete 208520
9 Defrost Damper Motor, Bi-directional 209715
10 Manual Speed Control, 5-Position 208383
11 Electronic Control Kit (Control Board, Transformer) 50002342-001
12 Thermistor Assembly 208365
13 Door Interlock Switch 208368
14 Door 50002340-001

Parts and Accessories Not Illustrated


Part Number Description
208374 Diffuser—5 in. diameter
208375 Diffuser—6 in. diameter
208379 Installation Parts Kit
208372 Airflow Balancing Kit*
W8150A1001 Fresh Air Ventilation Control
32003487-001 Digital Fan Timer, 20-minute
M23217A
Obsolete (available while supplies last)

94 customer.honeywell.com 70-6910
Fresh Air Ventilation Systems
HR150; HR200 Perfect Window® Fresh Air Ventilation Systems

Controls
Home
Perfect Window® Fresh Air Heat Recovery Ventilation Systems is a
heat recovery ventilator that provide proper levels of ventilation
with energy savings by transferring heat between the exhaust and
fresh air streams.
• Includes heat transfer core, pre-filters, fan and blower assembly, and
defrost.
• Provides ventilation that helps contractors meet ASHRAE 62-89.

Indoor Air Quality


• Automatic, economical, built-in defrost for operation to design
temperatures of -40F.
• Electronic ventilation fan timer option.
• Low voltage, high-speed override.
• Variable fan speed control.
• Easy-to-clean cross-flow aluminum core assures years of trouble-
free operation.
• Insulated cabinet.
• Rugged steel cabinet.

Combustion Controls
• Quiet operation.
• Permanent (washable) pre-filters.

Residential
• Integral balancing dampers.
• Includes vibration isolation hardware and duct collars.
Application: Heat Recovery Ventilator Frequency: 60 Hz
Type of Core: Aluminum cross flow core Temperature Recovery: 0.8
Electrical Ratings: 120 Vac

Current Draw, Nominal

Hydronic Controls
Airflow Capacity
(external static (maximum (minimum
Product Number pressure) Characteristics speed) speed) Defrost Control
* HR150B1005 188 cfm (0.2 in. wc) Heat Recovery Ventilator 150 CFM 1.7 A 0.7 A Built-in Defrost
* HR200B1005 206 cfm (0.2 in. wc) Heat Recovery Ventilator 200 CFM 1.7 A 0.8 A Built-in Defrost
* TRADELINE models • SUPER TRADELINE models

Controls
Water
Building Automation
Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 95
Fresh Air Ventilation Systems
Perfect Window Fresh Air Ventilation System Exploded View

12

13

10

9
6

1
11
6

14

Part Number for


No. Description HR150B or HR200B
1 Heat Transfer Core, Aluminum with Plastic Frame 209746
2 Blower Motor 208359
3 Blower Housing Kit 50002341-001
4 Motor Capacitor 209711
5 Foam Prefilter, Set of 2 209723
6 Clip for Foam Prefilter 209722
7 Drain Spout 208514
8 Door Latch, Complete 208520
9 Defrost Damper Motor, Bi-directional 209715
10 Manual Speed Control, 5-Position 208383
12 Electronic Control Kit (Control Board, Transformer) 50002342-001
13 Thermistor Assembly 208365
14 Door 50002340-001

Parts and Accessories Not Illustrated


Part Number Description
208374 Diffuser—5 in. diameter
208375 Diffuser—6 in. diameter
208379 Installation Parts Kit
208372 Airflow Balancing Kit*
W8150A1001 Fresh Air Ventilation Control
32003487-001 Digital Fan Timer, 20-minute
*Includes magnehelic pressure gauge and two 6 in. flow measuring stations.
M23216A
Obsolete (available while supplies last)

96 customer.honeywell.com 70-6910
Bath Fan Control/Fresh Air Ventilation
Digital Bath Fan Control

Controls
Home
Every home can benefit from proper ventilation. Honeywell’s new
Digital Bath Fan Control can operate a bath fan to meet ASHRAE
62.2 ventilation standards, allowing you to offer increased
ventilation control that is smart, affordable and efficient.
• Installs in place of a normal switch.
• Manually turn fan on/off or program to run at certain times of day for
increased energy efficiency and convenience.

Indoor Air Quality


• Can run in timer mode up to 60 minutes.
• Meets ASHRAE 62.2 Ventilation Standard, required or
recommended in most states and provinces for new construction or
whenever a permit is required.
• Easy-to-see backlit display shows current time to keep you on
schedule when getting ready.

Combustion Controls
Residential
Application: Fresh Air Ventilation Control

Product Number Characteristics


* HVC0001 Color White
* HVC0002 Color Biscuit

Hydronic Controls
* TRADELINE models • SUPER TRADELINE models

Y8150, W8150 Fresh Air Ventilation


The Y8150 Fresh Air Ventilation System provides fresh air to a
home. The control operates a fresh air intake damper and, when
necessary, activates the main HVAC blower to efficiently meet
ASHRAE ventilation rates.
• Designed to help meet local ventilation codes and standards,
including ASHRAE 62.2-2003 standard, Ventilation and Acceptable

Controls
Indoor Air Quality in Low-Rise Residential Buildings.

Water
• Microcontroller optimizes the air delivery schedule to make efficient
use of normal HVAC run times.
• Easy-to-use input dials allow customized ventilation for each
installation.
• Test mode that includes immediate feedback to installer to confirm
that air delivery requirements of selected ventilation standard are
being met.

Building Automation
• Economical supply-only ventilation; works with forced air system.
• Can be used with other equipment, such as an HRV/ ERV, for
balanced ventilation.

Application: Fresh Air Ventilation System


Electrical Ratings: 24 Vac

Components
Commercial
Current
Draw,
Airflow Nominal
Capacity
Pneumatic Controls

(external static (minimum


Product Number pressure) Characteristics speed) Used With
* W8150A1001 50 to 160 cfm Includes W8150A Fresh Air Ventilation Control, mounting 0.6 A EARD6, ER200B, ER200C, ER150C,
hardware, homeowner information label ER150B, HR200B, HR150B
* Y8150A1009 50 to 160 cfm Includes W8150A Fresh Air Ventilation Control, EARD6 0.6 A —
normally closed 6 inch damper, AT120B 120Vac/24Vac 20VA
transformer, mounting hardware for control, homeowner
information label
Industrial Combustion

* TRADELINE models • SUPER TRADELINE models


Controls

70-6910 97
Fresh Air Ventilation
Residential Ventilation Accessories
Product Number Description Used With
208379 Installation Parts Kit for HR150B, HR200B, ER150B, ER200B, HR150B; HR200B; ER150B; ER150C; ER200C; ER200B;
ER150C
209718 Auto Transformer HR150B; HR200B; ER150B; ER150C; ER200C; ER200B;
32003214-001 Weather Hood Kit HR150B; HR200B; ER150B; ER150C; ER200C; ER200B;
32003248-001 Blower Interface Kit HR150B; HR200B; ER150B; ER150C; ER200C; ER200B;
32003487-001 20 Minute Digital Fan Timer HR150B; HR200B; ER150B; ER150C; ER200C; ER200B;
50002342-001 Electronic Control Kit (includes Control Board and HR150B; HR200B; ER150B; ER150C; ER200C; ER200B;
Transformer) for ER150, ER200, HR150, HR200

Residential Ventilation Replacement Parts


Product Number Description Used With
208359 Blower Motor for HR150B, HR200B, ER150B, ER200B, HR150B; HR200B; ER150B; ER150C; ER200C; ER200B;
ER150C
208369 Auto Transformer HR150C; HR200C;
208383 Manual Speed Control, 5-position, for HR150B, HR200B, HR150B; HR200B; ER150B; ER150C; ER200C; ER200B;
ER150B, ER200B, ER150C
208515 Drain "T" Fitting HR150B, HR200B, ER150B, ER200B HR150B; HR200B; ER150B; ER150C; ER200C; ER200B;
208521 Defrost Damper Motor, Spring Return HR150C; HR200C;
209711 Motor Capacitor for HR150B, HR200B, ER150B, ER200B, HR150B; HR200B; ER150B; ER150C; ER200C; ER200B;
ER150C
209715 Defrost Damper Motor, Power Return HR150B; HR200B; ER150B; ER200B;
209719 Manual Control Circuit Board HR150B; HR200B; ER150B; ER150C; ER200C;
209722 Filter Clip HR150B; HR200B; ER150B; ER150C; ER200C;
209723 Foam Filter HR150B; HR200B;
209746 Aluminum heat transfer core for Fresh Air Ventilation systems HR150; HR200;
32002074-001 Cross Flow Enthalpy Core ER150B; ER150C; ER200C;
32002114-001 Foam Prefilter ER150B; ER150C; ER200C;

98 customer.honeywell.com 70-6910
Sail Switches
S688 Sail Switch

Controls
Home
The Sail Switch activates an electronic air cleaner, a humidifier, or
other equipment in response to airflow from the system fan. The
S688A is mounted in the return air duct where the sail will be in the
direct path of an unrestricted air stream.
• Simplified installations with multi-speed fans, in- accessible air
handlers, fan motors with voltage or phase different from controlled
equipment; eliminated wiring to system fan.

Indoor Air Quality


• Polyester film sail mounted on a micro switch snap switch.
• Removable spring counterbalances sail to allow mounting in either
vertical (up or down) or horizontal air flow.
• Top and bottom conduit knockouts for wiring convenience.
• Low air velocity switch operation makes at 250 fop and breaks at 75
fpm.

Combustion Controls
Residential
Dimensions, Approximate: 2 15/16 in. high x 3 3/4 in. wide x 2 in. Approvals:
deep (59 mm high x 95 mm wide x 51 mm deep) Canadian Standards Association: Certified
Sail Dimensions: 5 in. wide (max), 26.2 sq. in. of area (127 mm wide Underwriters Laboratories, Inc. UL Listed: File No. E4436, Guide No.
(max), 16,903 mm2) XAPX. For use in ambient temperatures normally prevailing in
Insertion Length: 10 in (254 mm) occupiable spaces, which usually are not higher than 77 F (25 C) but
Maximum Ambient Temperature: At switches: 125 F; At sail: 170 F (At occasionally may be as high as 104 F (40 C) for brief periods.

Hydronic Controls
switches: 52C; At sail: 77 C)

Contact Ratings Operating Velocity


Product Number (ALR) (AFL) (Resistive) Switching (fpm) (m/s)
S688A1007 N.O.Contacts: 12.0 A @ 24 Vac, N.O.Contacts: 2.0 A @ 24 Vac, N.O.Contacts: 5.0 A @ 24 SPDT 75 fpm- 0.4 m/s-
120 Vac 120 Vac Vac, 120 Vac 250 fpm 22.9 m/s
N.O.Contacts: 6.0 A @ 240 Vac N.O.Contacts: 1.0 A @ 240 Vac N.O.Contacts: 2.5 A @ 240
N.C.Contacts: 6.0 A @ 24 Vac, N.C.Contacts: 1.0 A @ 24 Vac, Vac
120 Vac 120 Vac N.C.Contacts: 2.5 A @ 24
N.C.Contacts: 3.0 A @ 240 Vac N.C.Contacts: 0.5 A @ 240 Vac Vac, 120 Vac, 240 Vac

Controls
Water
Sail Switch Accessories
Product Number Description Used With
123773A Sail assembly for S688A S688A

Building Automation
Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 99
Carbon Monoxide Alarm
C8600 Carbon Monoxide Alarm
Residential Carbon Monoxide Alarm with the most reliable
detection technology available.
• The only biotechnology-based infrared-gas sensor that mimics the
human response to carbon monoxide.
• Detects low levels of carbon monoxide (70 parts per million).
• Detects toxic CO gas resulting from incomplete combustion such as
emitted from appliances, furnaces, fireplaces and auto exhaust.
• Quick recovery-Rapidly returns to its original state when carbon
monoxide is eliminated from the environment.
• Every unit is 100% gas-tested to ensure accurate, timely response.
• Microprocessor intelligence-Self-tests every 10 minutes.
• Supervises sensor and alarm circuit status to ensure protection.
• Easy to install-no wiring, battery operation lets you locate the unit
almost anywhere.
• Energy easing design extends battery life to more than one year
under normal use.
• Low battery warning, chirps, and LED double flashes.
• Test/Retest button.
Mounting: Wall, Ceiling Mounted Approvals:
Color: Premier White® Underwriters Laboratories, Inc. 2034 Standard, c-UL Standard

Dimensions, Approximate
Product Number (inch) (mm) LEDs Includes
* C8600A1000 4 3/4 in. diameter x 1 1/2 in. high 121 mm diameter x 38 mm high Status and Diagnostic 9 volt alkaline battery
* TRADELINE models • SUPER TRADELINE models

100 customer.honeywell.com 70-6910


Combination Gas Controls
V400 Line Voltage; V800 Low Voltage Combination Gas Controls

Controls
Home
Used on gas fired standing pilot appliances with 30 mV
thermocouple. These gas controls include a manual gas valve,
safety shutoff, single millivoltage automatic operator, and pressure
regulator, pilot gas filter and flow adjustment, pressure tapping,
and thermocouple connector. V800 is used on 24V systems.
• Include pilot flow adjustment screw.
• Easy to install, adjust and service; all adjustments and connections

Indoor Air Quality


are accessible from top of control.
• Add separate energy cutoff (ECO) where codes call for dual safety
shutoff.
• Complete safety shutoff on pilot flame failure.
• LITE-RITE (OFF-PILOT-ON) lighting sequence.
• ECO connector for V800 models. Part No. 392451-1.

Combustion Controls
Dimensions in inches (millimeters)

Residential
5/16 (8) 3-3/16 (81)

3
4

Hydronic Controls
3-1/2 3-3/4 (95) 3-3/4 (95)
(89) 1
SWING PILOT CONNECTION SWING
4-3/4 RADIUS COMP. FITTING RADIUS
(121) FOR 1/4 O.D. TUBING

5/16 (8)
2

1-1/4
(32)
PRESSURE

Controls
Water
TAP 1/8 NPT
5/16 (8) 1-7/16 MOUNTING
(37) HOLES (2)
2-9/16 NO. 10-32 X
1-7/8 .25 DEEP
(65)
(48)
4-1/16 (103) 1-3/16
(37)

Building Automation
1 WITH V5306 (ILLUSTRATED), V5307 OR 5390 PRESSURE REGULATOR: 24V MODELS–3-1/2 (89), 120V MODEL–3-5/8 (92)
MANUAL MODELS–2-13/16 (71), FOR V5308 ADD 5/8 (16) TO DIMENSIONS GIVEN.

2 SIDE OUTLETS–LEFT AND RIGHT HAND. STANDARD ONLY ON TRADELINE MODELS.

3 CONTROL WITH 24V VALVE OPERATOR SHOWN. LINE VOLT MODEL HAS COVER FOR CONDUIT CONNECTION (TOP SURFACE). M16547A

4 ECO CONNECTOR ON STANDARD CAPACITY V800 ONLY.

Type: Single Stage Pilot Gas Outlet: Compression fitting for 1/4 in. OD tubing
Body Pattern: Straight-through, multi-tapped with 1/2 in. right and left Mounting: 0 to 90 degrees in any direction from the upright position of
outlets plugged the gas control knob, including vertically.

Components
Commercial
Capacity @ 1 in. p.d. 335,000 BTU/hr; 295,000 BTU/hr minimum
Approvals:
Ignition Type: Standing Pilot American Gas Association: AGA Design Certified; File No. L2025003,
Ambient Temperature Range: 32 F to 175 F (0 C to 79 C) CGA Design Certified; File No. L2025003, UL Component
Pressure Ratings: 1/2 psi (3.5 kPa) Recognized.
Pressure Tapping: 1/8 in. NPT with plug Underwriters Laboratories, Inc. UL Component Recognized.
Frequency: 60 Hz

Opening Inlet/ Pressure Regulator Setting


Pneumatic Controls

Characteristics Outlet
Type (standard, Size Electrical
Product Number of Gas step) (in.) (psi) (kPa) Ratings Includes
• V400A1095 Natural Standard 3/4 in. x 3.5 in. wc 0.87 kPa 120 Vac Two 3/4 x 1/2 in.; One 1/2 x 3/8 in.
3/4 in. Reducer Bushing/Adapters
V400C1036 Natural Step Opening 3/4 in. x Full Rate: 3.5 in. wc; Full Rate: 0.87 kPa; 120 Vac —
3/4 in. Step Setting: 0.7 in. wc Step Setting: 0.17 kPa
* V800A1070 Natural Standard 1/2 in. x 3.5 in. wc 0.87 kPa 24 Vac One 1/2 in. x 3/8 in. reducer bushing,
Industrial Combustion

or LP 3/4 in. One 3/4 in. x 1/2 in. reducer bushing,


Q340 Thermocouple,
Controls

Natural to LP Conversion Kit


* TRADELINE models • SUPER TRADELINE models

70-6910 101
Combination Gas Controls
Opening Inlet/ Pressure Regulator Setting
Characteristics Outlet
Type (standard, Size Electrical
Product Number of Gas step) (in.) (psi) (kPa) Ratings Includes
• V800A1088 Natural Standard 3/4 in. x 3.5 in. wc 0.87 kPa 24 Vac One 1/2 in. x 3/8 in. reducer bushing,
or LP 3/4 in. One 3/4 in. x 1/2 in. reducer bushing,
Q340 Thermocouple,
Natural to LP Conversion Kit
* V800A1476 Natural Standard 1/2 in. x 3.5 in. wc 0.87 kPa 24 Vac Natural to LP Conversion Kit
or LP 3/4 in.
* V800A1591 Natural Standard 3/4 in. x 3.5 in. wc 0.87 kPa 24 Vac Natural to LP Conversion Kit,
or LP 3/4 in. Two 3/4 x 1/2 in. reducer bushings
* V800C1052 Natural Step Opening 3/4 in. x Full Rate: 3.5 in. wc; Full Rate: 0.87 kPa; 24 Vac Two 3/4 x 1/2 in.; One 1/2 x 3/8 in.
3/4 in. Step Setting: 0.9 in. wc Step Setting: 0.22 kPa Reducer Bushing/Adapters
* TRADELINE models • SUPER TRADELINE models

Pressure Regulators—Standard and Step Opening


Servo gas pressure regulator for add-on or replacement use on
Honeywell V400,V800, VR400, VR800 and VR8440 Combination gas
controls. Utilizing the servo principle of operation, it controls
burner manifold pressure by repositioning the main valve
diaphragm.
• Interchangeable and adapt to all pipe sizes and capacities.
• Mount on top surface of control. Installation and adjustment readily
accomplished with a screwdriver.

Mounting: Top surface of combination gas control (two mounting


screws and a gasket).
Pressure Ratings: 1/2 psi (3.5 kPa)
Temperature Range: -40 F to +175 F (-40 C to +79 C)

Product Number Type of Gas Opening Characteristics (standard, step) Pressure Regulator Setting
* V5306B1009 Natural Standard Opening 3.5 in. wc; adj. range 3-5 in. wc
V5306B1033 LP Standard Opening 11.0 in. wc; adj. range 8-12 in. wc
* TRADELINE models • SUPER TRADELINE models

102 customer.honeywell.com 70-6910


Combination Gas Controls
VR4300 Continuous Pilot Dual Automatic Valve Combination Gas Control

Controls
Home
Combination gas control for use in 120 Vac, gas-fired, standing
pilot appliances with capacities from 30 to 300 cfh.
• Control includes safety shutoff, manual valve, two automatic
operators, pressure regulator and pilot adjustment.
• Compact size.
• Provides two automatic valves.
• Solenoid operated first automatic valve opens on thermostat call for

Indoor Air Quality


heat, closes when call for heat ends.
• Diaphragm-operated second automatic valve opens under control of
regulator; closes if gas or power supply is interrupted.
• Meets codes requiring dual safety shut-off.
• Natural to LP and LP to Natural conversion kits available for
standard and slow opening gas valves.
• All adjustments, wiring connections and pilot outlet are accessible
from top of control.
• Adjustable servo regulator effectively maintains almost constant gas

Combustion Controls
output pressure under wide fluctuations in gas supply pressure.
• Compatible with ECO connector.

Residential
• LITE-RITE (OFF-PILOT-ON) lighting sequence.

Wiring connections for 120 volt control Type: Single Stage


Body Pattern: Straight-through with flange
Capacity @ 1 in. p.d. 300,000 BTU/hr; 30,000 BTU/hr minimum
120V
THERMOSTAT Anticipator Setting: 0.13 A
Ignition Type: Standing Pilot
HIGH LIMIT

Hydronic Controls
CONTROLLER Ambient Temperature Range: 0 F to 175 F (-18 C to +79 C)
3 Pressure Ratings: 1/2 psi (3.5 kPa)
L1 Pressure Tapping: 1/8 in. NPT with plug
(HOT) Electrical Ratings: 120 Vac
1
L1 Frequency: 60 Hz
L2
2 L2 Pilot Gas Outlet: Compression fitting for 1/4 in. OD tubing
GAS CONTROL
TERMINALS Electrical Connections: 1/4 in. male quick connects; 24 in. (610 mm)
leadwire.
1 POWER SUPPLY. PROVIDE DISCONNECT MEANS Mounting: 0 to 90 degrees in any direction from the upright position of
AND OVERLOAD PROTECTION AS REQUIRED. the gas control knob, including vertically.
2 DO NOT JUMPER THESE TERMINALS. THIS Includes: One 1/2 in. x 3/8 in. reducer bushing, Two 3/4 x 1/2 in.

Controls
reducer bushings, 393691 Natural to LP gas conversion kit.

Water
SHORTS VALVE COIL AND MAY BURN OUT
ANTICIPATOR IN THERMOSTAT.
Approvals:
3 OPTIONAL HIGH LIMIT.
M3092B
American Gas Association: AGA Design Certified: File No. L2025006;
CGA Design Certified: File No. L2025006

Pressure Regulator Setting


Opening Characteristics Electrical

Building Automation
Product Number Type of Gas (standard, step) Inlet/Outlet Size (in.) (psi) (kPa) Ratings
* VR4300A4502 Natural Standard 3/4 in. x 3/4 in. 3.5 in. wc 0.87 kPa 120 Vac
* TRADELINE models • SUPER TRADELINE models

Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 103
Combination Gas Controls
VR8200 Continuous Pilot Dual Automatic Valve Combination Gas
Controls
Combination gas controls for use in 24 Vac, gas-fired, standing
pilot appliances with capacities from 20 to 200 cfh.
• Controls include manual valve, two automatic operators, servo
pressure regulator and pilot adjustment.
• Compact size.
• Provide two automatic valves.
• Solenoid-operated first automatic valve opens on thermostat call for
heat; closes when call for heat ends.
• Diaphragm-operated second automatic valve opens under control of
regulator; closes if gas or power supply is interrupted.
• Meet codes requiring dual safety shutoff.
• Natural to LP and LP to Natural conversion kits available for
standard and slow opening gas valves.
• LITE-RITE (OFF-PILOT-ON) lighting sequence.
• All adjustments, wiring connections and pilot outlet are accessible
from top of control.
• Adjustable servo regulator effectively maintains almost constant gas
output pressure under wide fluctuations in gas supply pressure.
• Compatible with ECO connector.

Dimensions in inches (millimeters) Body Pattern: Straight-through


Capacity @ 1 in. p.d. 130,000 BTU/hr; 20,000 BTU/hr minimum
1/4 in. QUICK- Anticipator Setting: 0.5 A
4 in. (102)
CONNECT Ignition Type: Standing Pilot
TERMINALS
SWING Ambient Temperature Range: 0 F to 175 F (-18 C to +79 C)
RADIUS Pressure Ratings: 1/2 psi (3.5 kPa)
Pressure Tapping: 1/8 in. NPT with plug
3-15/16 Electrical Ratings: 24 Vac
(99)
PV
Frequency: 60 Hz
1/2
PV/MV Pilot Gas Outlet: Compression fitting for 1/4 in. OD tubing
MV
(13) Electrical Connections: Combination screw and 1/4 in. male quick
connects.
Mounting: 0 to 90 degrees in any direction from the upright position of
1 (25)
the gas control knob, including vertically.
1-7/16
(36) Approvals:
American Gas Association: AGA Design Certificate: L2025006
1/2
Australian Gas Association: Australian Gas Assoc. Design
(13) Certificate: 4214; Approved for Delta C Applications
4-1/16 (104)
1 Canadian Gas Association: CGA Design Certificate: L2025006
(25)
M7495A
Underwriters Laboratories, Inc. UL Component Recognized: MH5323
2-11/16 (69)
Type: Single Stage

Opening Pressure Regulator Setting


Type of Characteristics Inlet/Outlet Size
Product Number Gas (standard, step) (in.) (psi) (kPa) Includes
• VR8200A2124 Natural Standard 1/2 in. x 1/2 in. 3.5 in. wc 0.87 kPa One 3/4 in. straight flange
One 1/2 in. x 3/8 in. reducer bushing
Q340 Thermocouple
Natural to LP Conversion Kit
* VR8200A2132 Natural Standard 1/2 in. x 1/2 in. 3.5 in. wc 0.87 kPa One 3/4 in. straight flange
One 1/2 in. x 3/8 in. reducer bushing
Natural to LP Conversion Kit
* VR8200H1251 Natural Slow Opening 1/2 in. x 1/2 in. 3.5 in. wc 0.87 kPa One 3/4 in. straight flange
One 1/2 in. x 3/8 in. reducer bushing
Natural to LP Conversion Kit
* TRADELINE models • SUPER TRADELINE models

104 customer.honeywell.com 70-6910


Combination Gas Controls
VR8300 Continuous Pilot Dual Automatic Valve Combination Gas

Controls
Home
Control
Combination gas control for use in 24 Vac, gas-fired, standing pilot
appliances with capacities from 30 to 300 cfh.
• Controls include safety shutoff, manual valve, two automatic
operators, pressure regulator and pilot adjustment.
• Compact size.

Indoor Air Quality


• Provide two automatic valves.
• Solenoid operated first automatic valve opens on thermostat call for
heat; closes when call for heat ends.
• Diaphragm-operated second automatic valve opens under control of
regulator; closes if gas or power supply is interrupted.
• Meets codes requiring dual safety shutoff.
• Natural to LP and LP to Natural conversion kits available for
standard and slow opening gas valves.
• All adjustments, wiring connections and pilot outlet are accessible

Combustion Controls
from top of control.
• Adjustable servo regulator effectively maintains almost constant gas

Residential
output pressure under wide fluctuations in gas supply pressure.
• Compatible with ECO connector.
• LITE-RITE (OFF-PILOT-ON) lighting sequence.

Dimensions in inches (millimeters) Type: Single Stage


Body Pattern: Straight through with integral tapping; with flange
4 IN. (102) MAX Capacity @ 1 in. p.d. 190,000 BTU/hr; 30,000 BTU/hr minimum

Hydronic Controls
1/4 INCH
SWING RADIUS QUICK-CONNECT Anticipator Setting: 0.7 A
TERMINALS
Ignition Type: Standing Pilot
Ambient Temperature Range: 0 F to 175 F (-18 C to +79 C)
(FOR FLANGE Pressure Ratings: 1/2 psi (3.5 kPa)
TH
MOUNTING) TR 3-15/16 Pressure Tapping: 1/8 in. NPT with plug
(99)
8-32 TAPPED (4) Electrical Ratings: 24 Vac
1 Frequency: 60 Hz
1/2
Pilot Gas Outlet: Compression fitting for 1/4 in. OD tubing
1 (13) Electrical Connections: 1/4 in. quick-connect male terminals
(25)
Mounting: 0 to 90 degrees in any direction from the upright position of
1-7/16
the gas control knob, including vertically.

Controls
(36)

Water
2-3/16
(56) Approvals:
2
American Gas Association: AGA Design Certified: File No. L2025006.
Canadian Gas Association: CGA Design Certified: File No. L2025006.
1 (25) 4-1/16 (104) 1/2
(13) Underwriters Laboratories, Inc. UL Component Recognized.
1 FLANGE FACTORY MOUNTED ON 3/4 X 3/4 INCH 1 (25)
MODELS ONLY. 2-11/16 (69) M23233

Building Automation
2 STEP-OPEN MODELS ONLY.

Opening Pressure Regulator Setting


Type of Characteristics Inlet/Outlet Size
Product Number Gas (standard, step) (in.) (psi) (kPa) Includes
* VR8300A3500 Natural Standard 1/2 in. x 3/4 in. 3.5 in. wc 0.87 kPa One 3/4 x 1/2 in. reducer bushing
393691 Natural to LP gas conversion kit.
• VR8300A3518 Natural Standard 1/2 in. x 3/4 in. 3.5 in. wc 0.87 kPa One 3/4 x 1/2 in. reducer bushing
393691-14 bag assembly,
3/4 in. straight flange with O ring, screws and

Components
Commercial
wrench
393200 ECO adapter
Q340 (36 in.) thermocouple with adapters
393691 Natural to LP gas conversion kit.
VR8300A3567 Natural Standard 1/2 in. x 3/4 in. 3.5 in. wc 0.87 kPa One 3/4 x 1/2 in. reducer bushing
393691 Natural to LP gas conversion kit.
* VR8300A4508 Natural Standard 3/4 in. x 3/4 in. 3.5 in. wc 0.87 kPa Two 3/4 x 1/2 in. reducer bushing
393691 Natural to LP gas conversion kit.
Pneumatic Controls

• VR8300A4516 Natural Standard 3/4 in. x 3/4 in. 3.5 in. wc 0.87 kPa Two 3/4 x 1/2 in. reducer bushing
393200 ECO adapter
Q340 (36 in.) thermocouple with adapters
393691 Natural to LP gas conversion kit.
VR8300A4557 Natural Standard 3/4 in. x 3/4 in. 3.5 in. wc 0.87 kPa Two 3/4 x 1/2 in. reducer bushing
393691 Natural to LP gas conversion kit.
VR8300A4565 Natural Standard 3/4 in. x 3/4 in. 3.5 in. wc 0.87 kPa Two 3/4 x 1/2 in. reducer bushing
393200 ECO adapter
Industrial Combustion

Q340 (36 in.) thermocouple with adapters


393691 Natural to LP gas conversion kit.
Controls

* TRADELINE models • SUPER TRADELINE models

70-6910 105
Combination Gas Controls
Opening Pressure Regulator Setting
Type of Characteristics Inlet/Outlet Size
Product Number Gas (standard, step) (in.) (psi) (kPa) Includes
* VR8300C4506 Natural Step Opening 3/4 in. x 3/4 in. Full Rate: 3.5 Full Rate: 0.87 Two 3/4 x 1/2 in. reducer bushings
in. wc; Step kPa; Step
Setting: 0.9 in. Setting: 0.22
wc kPa
VR8300H2109 Natural Slow Opening 1/2 in. x 1/2 in. 3.5 in. wc 0.87 kPa —
VR8300H4501 Natural Slow Opening 3/4 in. x 3/4 in. 3.5 in. wc 0.87 kPa —
* TRADELINE models • SUPER TRADELINE models

VR4304 Intermittent Pilot Dual Automatic Valve Combination Gas


Controls
Combination gas control for use in 120 Vac, gas-fired, intermittent
pilot appliances with capacities from 30 to 415 cfh.
• Controls include safety shutoff, manual valve, two automatic
operators, pressure regulator and pilot adjustment.
• Use with S86F,H; S860D; S8600F,H; S8610 and S90A,B Control
Modules.
• Compact size. Provide two automatic valves.
• Solenoid operated first automatic valve opens on thermostat call for
heat; closes when call for heat ends.
• Diaphragm-operated second automatic valve opens under control of
regulator; closes if gas or power supply is interrupted.
• Meet codes requiring dual safety shutoff.
• Standard and slow opening natural gas models include natural to LP
gas conversion kit; LP to natural gas conversion kit also available.
• All adjustments, wiring connections and pilot outlet are accessible
from top of control.
• Adjustable servo regulator effectively maintains almost constant gas
output pressure under wide fluctuations in gas supply pressure.
• Compatible with ECO connector.
• ON-OFF lighting sequence.
Type: Single Stage Frequency: 60 Hz
Dimensions, Approximate: 5 3/8 in. high x 4 1/16 in. wide x 2 11/16 in. Pilot Gas Outlet: Compression fitting for 1/4 in. OD tubing
deep (135 mm high x 104 mm wide x 69 mm deep) Electrical Connections: 1/4 in. quick-connect male terminals
Body Pattern: Straight-through Mounting: 0 to 90 degrees in any direction from the upright position of
Capacity @ 1 in. p.d. 300,000 BTU/hr; 30,000 BTU/hr minimum the gas control knob, including vertically.
Anticipator Setting: 0.1 A Includes: One 1/2 in. x 3/8 in. reducer bushing, Natural to LP Conversion
Ignition Type: Intermittent Pilot Kit, Two 3/4 x 1/2 in. reducer bushings
Ambient Temperature Range: -40 F to +175 F (-40 C to +79 C) Approvals:
Pressure Ratings: 1/2 psi (3.5 kPa) American Gas Association: AGA Design Certified: File No. L2025007;
Pressure Tapping: 1/8 in. NPT with plug CGA Design Certified: File No. L2025007
Electrical Ratings: 120 Vac

Pressure Regulator Setting


Opening Characteristics Electrical
Product Number Type of Gas (standard, step) Inlet/Outlet Size (in.) (psi) (kPa) Ratings
* VR4304M4519 Natural Standard 3/4 in. x 3/4 in. 3.5 in. wc 0.87 kPa 120 Vac
* TRADELINE models • SUPER TRADELINE models

106 customer.honeywell.com 70-6910


Combination Gas Controls
VR8204 Intermittent Pilot Dual Automatic Valve Combination Gas

Controls
Home
Controls
Combination gas controls for use in 24 Vac, gas-fired, intermittent
pilot appliances with capacities from 20 to 200 cfh.
• Controls include manual valve, two automatic operators, servo
pressure regulator and pilot adjustment.
• Use with S86F,H; S8600F,H and S8610 Control Modules.

Indoor Air Quality


• Compact size.
• Provide two automatic valves.
• Solenoid operated first automatic valve opens on thermostat call for
heat; closes when call for heat ends.
• Diaphragm operated second automatic valve opens under control of
regulator; closes if gas or power supply is interrupted.
• Meet codes requiring dual safety shutoff.
• Natural to LP and LP to Natural conversion kits available for
standard and slow opening gas valves.

Combustion Controls
• All adjustments and wiring connections are accessible from top of
control.

Residential
• ON-OFF lighting sequence.

Dimensions in inches (millimeters) Type: Single Stage


Body Pattern: Straight-through
1/4 in. QUICK- Capacity @ 1 in. p.d. 150,000 BTU/hr; 20,000 BTU/hr minimum
3-5/8 (91) CONNECT Anticipator Setting: 0.5 A
TERMINALS
SWING Ignition Type: Intermittent Pilot
RADIUS

Hydronic Controls
Pressure Ratings: 1/2 psi (3.5 kPa)
Pressure Tapping: 1/8 in. NPT with plug
3-1/2
Electrical Ratings: 24 Vac
PV
PV/MV (89) Frequency: 60 Hz
MV
Pilot Gas Outlet: Compression fitting for 1/4 in. OD tubing
1/2 (13)
Electrical Connections: 1/4 in. quick-connect male terminals
Mounting: 0 to 90 degrees in any direction from the upright position of
1 (25) the gas control knob, including vertically.
1-7/16 Approvals:
(36)
American Gas Association: AGA Design Certificate: L2025006
Australian Gas Association: Australian Gas Assoc. Design

Controls
1/2

Water
(13) Certificate: 4214; Approved for Delta C Applications
4-1/2 (104) 1
(25)
Canadian Gas Association: CGA Design Certificate: L2025006
Underwriters Laboratories, Inc. UL Component Recognized: MH5323
2-11/16 (69) M8151A

Ambient
Inlet/ Temperature

Building Automation
Opening Outlet Pressure Regulator Setting Range
Type of Characteristics Size
Product Number Gas (standard, step) (in.) (psi) (kPa) (F) (C) Includes
* VR8204A2076 Natural Standard 1/2 in. x 3.5 in. wc 0.87 kPa 0 F to -18 C to One 3/4 in. straight flange
1/2 in. 175 F +79 C One 1/2 in. x 3/8 in. reducer
bushing
Natural to LP Conversion Kit
VR8204C1019 Natural Step Opening 1/2 in. x Full Rate: Full Rate: 0 F to -18 C to —
1/2 in. 3.5 in. wc; 0.87 kPa; 175 F +79 C
Step Setting: Step Setting:
0.9 in. wc 0.22 kPa

Components
Commercial
VR8204H1006 Natural Slow Opening 1/2 in. x 3.5 in. wc 0.87 kPa 0 F to -18 C to —
1/2 in. 175 F +79 C
* VR8204M1091 Natural Standard 1/2 in. x 3.5 in. wc 0.87 kPa -40 F to -40 C to One 3/4 in. straight flange
1/2 in. +175 F +79 C One 1/2 in. x 3/8 in. reducer
bushing
Natural to LP Conversion Kit
* TRADELINE models • SUPER TRADELINE models
Pneumatic Controls
Industrial Combustion
Controls

70-6910 107
Combination Gas Controls
VR8245 Intermittent Pilot Combination Gas Control
These universal electronic ignition gas controls are used in gas-
fired appliances with capacities up to 150 cu ft/hour at 1 inch wc
pressure drop (4.2 cu m/hour at 0.25 kPa) for natural gas. The
VR8245M will operate with a direct spark (DSI), hot surface (HSI) or
intermittent pilot ignition. The control includes a manual valve, two
automatic operators, a pressure regulator, pilot adjustment, pilot
plug and ignition adapter.

Type: Single Stage Pressure Ratings: 1/2 psi (3.5 kPa)


Body Pattern: Straight-through Electrical Ratings: 24 Vac
Capacity @ 1 in. p.d. 150,000 BTU/hr Frequency: 60 Hz, 50 Hz
Ignition Type: Intermittent Pilot Mounting: 0 to 90 degrees in any direction from the upright position of
Ambient Temperature Range: -40 F to +175 F (-40 C to +79 C) the gas control knob, including vertically.

Pressure Regulator Setting


Opening Characteristics Inlet/Outlet
Product Number Type of Gas (standard, step) Size (in.) (psi) (kPa) Includes
VR8245M2530 Natural or LP Standard 1/2 in. x 1/2 in. 3.5 in. wc 0.9 kPa One 1/2 in. x 3/8 in. reducer
bushing
Natural to LP Conversion Kit

108 customer.honeywell.com 70-6910


Combination Gas Controls
VR8304 Intermittent Pilot Dual Automatic Valve Combination Gas

Controls
Home
Control
Combination gas control for use in 24 Vac, gas-fired, intermittent
pilot appliances with capacities from 30 to 415 cfh.
• Controls include safety shutoff, manual valve, two automatic
operators, pressure regulator and pilot adjustment.
• Use with S86F,H; S860D; S8600F,H; S8610 and S90A,B Control

Indoor Air Quality


Modules.
• Compact size.
• Provide two automatic valves. Solenoid operated first automatic
valve opens on thermostat call for heat; closes when call for heat
ends.
• Diaphragm-operated second automatic valve opens under control of
regulator; closes if gas or power supply is interrupted.
• Meet codes requiring dual safety shutoff.
• Natural to LP and LP to Natural conversion kits available for

Combustion Controls
standard and slow opening gas valves.
• All adjustments, wiring connections and pilot outlet are accessible

Residential
from top of control.
• Adjustable servo regulator effectively maintains almost constant gas
output pressure under wide fluctuations in gas supply pressure.
• Compatible with ECO connector.
• ON-OFF lighting sequence.

Dimensions in inches (millimeters) Type: Single Stage


Body Pattern: Straight-through

Hydronic Controls
1/4 in. QUICK- Capacity @ 1 in. p.d. 300,000 BTU/hr; 30,000 BTU/hr minimum
4 in. (102)
CONNECT Anticipator Setting: 0.7 A
TERMINALS
SWING Ignition Type: Intermittent Pilot
RADIUS Pressure Ratings: 1/2 psi (3.5 kPa)
Pressure Tapping: 1/8 in. NPT with plug
3-15/16 Electrical Ratings: 24 Vac
(99)
PV
Frequency: 60 Hz
1/2
PV/MV Pilot Gas Outlet: Compression fitting for 1/4 in. OD tubing
MV
(13) Electrical Connections: 1/4 in. quick-connect male terminals
Mounting: 0 to 90 degrees in any direction from the upright position of
the gas control knob, including vertically.

Controls
Water
1 (25)
Approvals:
1-7/16
(36)
American Gas Association: AGA Design Certified: File No. L2025007.
Canadian Gas Association: CGA Design Certified: File No. L2025007.
1/2
Underwriters Laboratories, Inc. UL Component Recognized.
(13)
4-1/16 (104)
1

Building Automation
(25)
2-11/16 (69) M7495A

Opening Ambient
Character- Inlet/ Temperature
istics Outlet Pressure Regulator Setting Range
Type of (standard, Size
Product Number Gas step) (in.) (psi) (kPa) (F) (C) Includes
VR8304H4503 Natural Slow 3/4 in. x 3.5 in. wc 0.87 kPa 0 F to -18 C to 393691 Natural to LP gas
Opening 3/4 in. 175 F +79 C conversion kit.
VR8304M2501 Natural Standard 1/2 in. x 3.5 in. wc 0.87 kPa -40 F to -40 C to 393691 Natural to LP gas

Components
Commercial
1/2 in. +175 F +79 C conversion kit.
* VR8304M3509 Natural Standard 1/2 in. x 3.5 in. wc 0.87 kPa -40 F to -40 C to One 3/4 in. x 1/2 in.
3/4 in. +175 F +79 C reducer bushing; 393691
Natural to LP gas
conversion kit.
* VR8304M4507 Natural Standard 3/4 in. x 3.5 in. wc 0.87 kPa -40 F to -40 C to Two 3/4 in. x 1/2 in.
3/4 in. +175 F +79 C reducer bushing; 393691
Pneumatic Controls

Natural to LP gas
conversion kit.
VR8304P4330 LP Step 3/4 in. x Full Rate: 10.0 in. wc; Full Rate: 2.49 kPa; -40 F to -40 C to —
Opening 3/4 in. Step Setting: 2.5 in. wc Step Setting: 0.62 kPa +175 F +79 C
VR8304P4504 Natural Step 3/4 in. x Full Rate: 3.5 in. wc; Full Rate: 0.87 kPa; -40 F to -40 C to —
Opening 3/4 in. Step Setting: 0.9 in. wc Step Setting: 0.22 kPa +175 F +79 C
VR8304Q4511 Natural Standard 3/4 in. x 1.7 in. wc low; 3.5 in. wc 0.48 kPa low; 0.87 kPa -40 F to -40 C to Natural to LP Conversion
3/4 in. high high +175 F +79 C Kit Two 3/4 x 1/2 in.
Industrial Combustion

reducer bushings
* TRADELINE models • SUPER TRADELINE models
Controls

70-6910 109
Combination Gas Controls
VR4305 Direct Ignition Dual Automatic Valve Combination Gas Control
Combination gas control for use with hot surface/direct spark
systems in 120 Vac, gas-fired appliances, with capacities from 30
to 415 cfh.
• Controls include manual valve, two automatic operators and
pressure regulator.
• Compact size.
• Provides two automatic valves.
• Solenoid operated first automatic valve opens on thermostat call for
heat; closes when call for heat ends.
• Diaphragm-operated second automatic valve opens under control of
regulator; closes if gas or power supply is interrupted.
• Meets codes requiring dual safety shut-off.
• Natural to LP and LP to Natural conversion kits available for
standard and slow opening gas valves.
• Adjustable servo regulator effectively maintains almost constant gas
output pressure under wide fluctuations in gas supply pressure.
• ON/OFF lighting sequence.
Type: Single Stage Electrical Connections: 1/4 in. male quick-connects; 24 in. (610 mm)
Body Pattern: Straight-through leadwires.
Capacity @ 1 in. p.d. 300,000 BTU/hr; 30,000 BTU/hr minimum Mounting: 0 to 90 degrees in any direction from the upright position of
Anticipator Setting: 0.13 A the gas control knob, including vertically.
Ignition Type: Direct Ignition Includes: One 1/2 in. x 3/8 in. reducer bushing, Natural to LP Conversion
Ambient Temperature Range: -40 F to +175 F (-40 C to +79 C) Kit, Two 3/4 x 1/2 in. reducer bushings
Pressure Ratings: 1/2 psi (3.5 kPa) Approvals:
Pressure Tapping: 1/8 in. NPT with plug American Gas Association: AGA Design Certified: File No. L2025007.
Electrical Ratings: 120 Vac Canadian Gas Association: CSA Design Certified: File No. L2025007.
Frequency: 60 Hz Underwriters Laboratories, Inc. UL Component Recognized.

Pressure Regulator Setting


Opening Characteristics Electrical
Product Number Type of Gas (standard, step) Inlet/Outlet Size (in.) (psi) (kPa) Ratings
* VR4305M4532 Natural Standard 3/4 in. x 3/4 in. 3.5 in. wc 0.87 kPa 120 Vac
* TRADELINE models • SUPER TRADELINE models

110 customer.honeywell.com 70-6910


Combination Gas Controls
VR8205 Direct Ignition Dual Automatic Valve Combination Gas

Controls
Home
Controls
Combination gas controls for use with hot surface/direct spark
systems in 24 Vac, gas-fired appliances with capacities from 20 to
200 cfh.
• Controls include manual valve, two automatic operators, and
pressure regulator.

Indoor Air Quality


• Provide two automatic valves.
• Solenoid operated first automatic valve opens on thermostat call for
heat; closes when call for heat ends.
• Diaphragm operated second automatic valve opens under control of
the regulator; closes if gas or power supply is interrupted.
• Meet codes requiring dual safety shutoff.
• Natural to LP and LP to Natural conversion kits available for
standard and slow opening gas valves.
• Adjustments and wiring connections are accessible from top of the

Combustion Controls
control.
• ON-OFF lighting sequence.

Residential
Dimensions in inches (millimeters) Body Pattern: Straight-through
Capacity @ 1 in. p.d. 150,000 BTU/hr; 20,000 BTU/hr minimum
(FOR FLANGE 1/4 in. QUICK- Anticipator Setting: 0.5 A
3-5/8 (91)
MOUNTING)
SWING
CONNECT Ignition Type: Direct Ignition
8-32 TAPPED (4)
RADIUS
TERMINALS Pressure Ratings: 1/2 psi (3.5 kPa)
Pressure Tapping: 1/8 in. NPT with plug

Hydronic Controls
Electrical Ratings: 24 Vac
Frequency: 60 Hz
MV 3-1/2 Electrical Connections: 1/4 in. quick-connect male terminals
MV (89) Mounting: 0 to 90 degrees in any direction from the upright position of
1/2 (13)
the gas control knob, including vertically.
Approvals:
1 (25) American Gas Association: AGA Design Certified: File No. L2025006.
1-7/16 Canadian Gas Association: CGA Design Certified: File No. L2025006.
(36) Underwriters Laboratories, Inc. UL Component Recognized.
1/2

Controls
4-1/8 (108) (13)

Water
1
(25)
2-11/16
(69) M8152A

Ambient
Inlet/ Pressure Regulator Temperature
Opening Outlet

Building Automation
Setting Range
Type of Characteristics Size
Product Number Gas (standard, step) (in.) (psi) (kPa) (F) (C) Type Includes
* VR8205A2024 Natural Standard 1/2 in. x 3.5 in. wc 0.87 kPa 0 F to -18 C to Single One 3/4 in. straight flange
1/2 in. 175 F +79 C Stage One 1/2 in. x 3/8 in. reducer
bushing
Natural to LP Conversion Kit
VR8205C1024 Natural Step Opening 1/2 in. x Full Rate: Full Rate: 0 F to -18 C to Single —
1/2 in. 3.5 in. wc; 0.87 kPa; 175 F +79 C Stage
Step Setting: Step Setting:
1.2 in. wc 0.30 kPa

Components
Commercial
VR8205H1003 Natural Slow Opening 1/2 in. x 3.5 in. wc 0.87 kPa 0 F to -18 C to Single —
1/2 in. 175 F +79 C Stage
VR8205Q2555 Natural Standard 1/2 in. x 1.7 in. wc low; -40 F to -40 C to Two One 1/2 in. x 3/8 in. reducer
1/2 in. 3.5 in. wc high +175 F +66 C Stage bushing
Natural to LP Conversion Kit
* TRADELINE models • SUPER TRADELINE models
Pneumatic Controls
Industrial Combustion
Controls

70-6910 111
Combination Gas Controls
VR8305 Direct Ignition Dual Automatic Valve Combination Gas
Control
Combination gas control for use with hot surface/direct spark
systems in 24 Vac, gas-fired appliances, with capacities from 30 to
415 cfh.
• Controls include manual valve, two automatic operators, and
pressure regulator.
• Use with S89C,E,F and S87 series 5 and later.
• Compact size.
• Provide two automatic valves.
• Solenoid-operated first automatic valve opens on thermostat call for
heat; closes when call for heat ends.
• Diaphragm-operated second automatic valve opens under control of
regulator; closes if gas or power supply is interrupted.
• Meet codes requiring dual safety shut-off.
• All adjustments, wiring connections and pilot outlet are accessible
from top of control.
• Adjustable servo regulator effectively maintains almost constant gas
output pressure under wide fluctuations in gas supply pressure.
• ON-OFF lighting sequence.
• Natural to LP and LP to Natural conversion kits available for
standard and slow opening gas valves.

Dimensions in inches (millimeters) Body Pattern: Straight-through


Capacity @ 1 in. p.d. 240,000 BTU/hr; 30,000 BTU/hr minimum
(FOR FLANGE
1/4 in. QUICK- Anticipator Setting: 0.62 A
MOUNTING) 4 in. (102) CONNECT Ignition Type: Direct Ignition
TERMINALS
8-32 TAPPED (4) SWING Pressure Ratings: 1/2 psi (3.5 kPa)
RADIUS
Pressure Tapping: 1/8 in. NPT with plug
Electrical Ratings: 24 Vac
Ambient Temperature Range: -40 F to +175 F (-40 C to +79 C)
3-15/16
(99) Frequency: 60 Hz
MV
Electrical Connections: 1/4 in. quick-connect male terminals
1/2 MV Mounting: 0 to 90 degrees in any direction from the upright position of
(13)
the gas control knob, including vertically.
Approvals:
1 (25) American Gas Association: AGA Design Certificate: L2025006
1-7/16 Australian Gas Association: Australian Gas Assoc. Design
(36) Certificate: 4214; Approved for Delta C Applications
Canadian Gas Association: CGA Design Certificate: L2025006
1/2
4-1/16 (104) (13) Underwriters Laboratories, Inc. UL Component Recognized: MH8191
1
(25)
M7496A
2-11/16 (69)

Opening Pressure Regulator Setting


Characteris- Inlet/
tics Outlet
Type of (standard, Size
Product Number Gas step) (in.) (psi) (kPa) Type Includes
VR8305M2102 Natural Standard 1/2 in. x 3.5 in. wc 0.87 kPa Single —
1/2 in. Stage
* VR8305M3506 Natural Standard 1/2 in. x 3.5 in. wc 0.87 kPa Single One 3/4 in. straight flange
3/4 in. Stage One 3/4 in. x 1/2 in. reducer bushing
Natural to LP Conversion Kit
VR8305P2224 LP Step Opening 1/2 in. x Full Rate: 10.0 in. wc; Full Rate: 2.49 kPa; Single —
1/2 in. Step Setting: 4.0 in. wc Step Setting: 1.0 kPa Stage
VR8305P4279 Natural Step Opening 3/4 in. x Full Rate: 3.5 in. wc; Full Rate: 0.87 kPa; Single —
3/4 in. Step Setting: 0.9 in. wc Step Setting: 0.22 kPa Stage
VR8305Q4500 Natural Standard 3/4 in. x 1.7 in. wc low; 0.48 kPa low; Two Natural to LP Conversion Kit
3/4 in. 3.5 in. wc high 0.87 kPa high Stage Two 3/4 x 1/2 in. reducer bushings
* TRADELINE models • SUPER TRADELINE models

112 customer.honeywell.com 70-6910


Combination Gas Controls
VR8345 Universal Electronic Ignition Combination Gas Control

Controls
Home
Universal electronic ignition combination gas control for use with
direct spark ignition, hot surface ignition or intermittent pilot
ignition in 24 Vac, gas-fired appliances, with capacities from 30 to
415 cfh.
• Control includes manual valve, two automatic operators, pressure
regulator, pilot adjustment, pilot plug and ignition adapter.
• Replaces virtually any IP, HSI, or DSI gas control.

Indoor Air Quality


• For use with natural or manufactured gas or LP gas.
• Includes converter kit to adapt from natural to LP gas.
• Compact size.
• All adjustments and wiring connections accessible from top of
control.
• Four-inch swing radius allows easy rotation into position inside the
tightest furnace vestibules.
• Clearly marked, keyed terminal block allows quick attachment of
wires and IP/DSI/HSI jumper.

Combustion Controls
• Internal inlet screen blocks contaminants in gas line from entering
valve.

Residential
Dimensions in inches (millimeters) Type: Single Stage
Body Pattern: Straight-through
1/4 in. QUICK- Capacity @ 1 in. p.d. 300,000 BTU/hr; 30,000 BTU/hr minimum
4 in. (102) CONNECT Ignition Type: Direct Ignition; Intermittent Pilot
TERMINALS
SWING Ambient Temperature Range: -40 F to +175 F (-40 C to +79 C)
RADIUS
Pressure Ratings: 1/2 psi (3.5 kPa)

Hydronic Controls
Pressure Tapping: 1/8 in. NPT with plug
Electrical Ratings: 24 Vac
3-15/16 Frequency: 60 Hz
PV
PV
(99) Electrical Connections: 1/4 in. quick-connect male terminals
MV
MV
Mounting: 0 to 90 degrees in any direction from the upright position of
the gas control knob, including vertically.
Includes: Natural to LP Conversion Kit, Two 3/4 x 1/2 in. reducer bushings
Approvals:
American Gas Association: AGA Design Certified: File No. L2025007.
1-7/16 Canadian Gas Association: CGA Design Certified: File No. L2025007.
(36) Underwriters Laboratories, Inc. UL Component Recognized.

Controls
Water
4-1/16 (104) 2-11/16 (69) M7449B

Pressure Regulator Setting


Type of Opening Characteristics
Product Number Gas (standard, step) Inlet/Outlet Size (in.) (psi) (kPa)

Building Automation
• VR8345H4555 Natural Slow Opening 3/4 in. x 3/4 in. 3.5 in. wc 0.87 kPa
VR8345M4302 Natural Standard 3/4 in. x 3/4 in. 3.5 in. wc 0.87 kPa
VR8345M4336 Natural Standard 3/4 in. x 3/4 in. 3.5 in. wc 0.87 kPa
• VR8345Q4563 Natural Standard 3/4 in. x 3/4 in. 1.7 in. wc low; 3.5 in. wc high 0.48 kPa low; 0.87 kPa high
* TRADELINE models • SUPER TRADELINE models

Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 113
Millivoltage Combination Gas Controls
VS820 Millivoltage Combination Gas Controls
These gas controls combine a Lite-Rite manual gas cock, safety
shutoff Pilotstat assembly, millivoltage automatic valve operator,
and optional gas pressure regulator. They require the use of a 750
mv Powerpile generator (thermopile). The generator, heated by the
pilot burner flame, provides the electrical energy to operate the
combination gas control. A millivoltage thermostat with suitable
accessory controls completes the automatic control system for the
heating appliance.
• Include pilot flow adjustment screw.
• Easy to install, adjust and service; all adjustments and connections
are accessible from top of control.
• Add separate energy cutoff (ECO) where codes call for dual safety
shutoff.
• Complete safety shutoff on pilot flame failure.
• LITE-RITE (OFF-PILOT-ON) lighting sequence.
• ECO connector for V800 models, Part No. 392451-1.
Application: Self-powered automatic control. Use with 750 mV pilot Pilot Gas Outlet: Compression fitting for 1/4 in. OD tubing.
generator. Electrical Connections: Terminal block has 3 combination screw and
Dimensions, Approximate: 4 3/4 in. high x 4 1/16 in. wide x 3 3/16 in. 1/4 in. quick connect terminals.
deep (121 mm high x 103 mm wide x 81 mm deep) Mounting: 0 to 90 degrees in any direction from the upright position of
Body Pattern: Straight-through. multi-tapped with 1/2 in. right and left the gas control knob, including vertically.
outlets plugged, except as noted.
Approvals:
Pressure Ratings: 1/2 psi (3.5 kPa) American Gas Association: AGA Design Certified: File no. L2025003
Pressure Tapping: 1/8 in. npt with plug. Canadian Gas Association: CGA Design Certified: File no. L2025003
Temperature Range: 32 F to 175 F (0 C to 79 C) Underwriters Laboratories, Inc. UL Component Recognized
Electrical Ratings: 750 mV

Pressure Regulator Setting


Type of Pressure
Product Number Gas Inlet/Outlet Size (in.) Regulator (psi) (kPa) Includes
* VS820A1047 Natural 1/2 in. NPT x 3/4 in. Standard 3.5 in. wc Reg. Set/ 0.87 kPa One 3/4 in. x 1/2 in. reducer bushing;
NPT with 1/2 in. NPT 3-5 in. Adj. Range one 1/2 in. x 3/8 in. reducer bushing
side outlets One 1/2 in. x 3/8 in. reducer bushing
One 3/4 in. x 1/2 in. reducer bushing
* VS820A1054 Natural 3/4 in. NPT x 3/4 in. Standard 3.5 in. wc Reg. Set/ 0.87 kPa Two 3/4 in. x 1/2 in. reducer bushings
NPT with 1/2 in. NPT 3-5 in. Adj. Range One 1/2 in. x 3/8 in. reducer bushing
side outlets
• VS820A1088 Natural 3/4 in. NPT x 3/4 in. Standard 3.5 in. wc Reg. Set/ 0.87 kPa Remote Rod Adapter
NPT with 1/2 in. NPT 3-5 in. Adj. Range One Natural to LP Conversion Kit
side outlets Two 3/4 in. x 1/2 in. reducer bushings
One 1/2 in. x 3/8 in. reducer bushing
* VS820A1336 LP 3/4 in. NPT x 3/4 in. Standard 10.0 in. wc Reg. Set/ 2.49 kPa One 1/2 in. x 3/8 in. reducer bushing
NPT with 1/2 in. NPT 8-12 in. Adj. Range One 3/4 in. x 1/2 in. reducer bushing
side outlets
* VS820C1100 Natural 3/4 in. NPT x 3/4 in. Step Opening Step: 0.9 in. wc non- Step: 0.22 kPa; One 1/2 in. x 3/8 in. reducer bushing
NPT with 1/2 in. NPT adjustable; Full rate: 0.87 kPa One 3/4 in. x 1/2 in. reducer bushing
side outlets Full rate: 3.5 in. wc,
3-5 in. adjustable
* TRADELINE models • SUPER TRADELINE models

114 customer.honeywell.com 70-6910


Gas Valve Selection Guide
Gas Valve Selection Guide

Controls
Home
Trade Replacements (Double-
Check Specifications Before
Replacement) Specifications Accessories (Includes)

Indoor Air Quality


Opening Pressure 3/4 in. x Natural to 1/2 in. x
Direct Service Characteristics Inlet/ Regulator 1/2 in. LP 3/4 in. 3/8 in. Remote
Universal Part (standard, Outlet Setting Temperature Q340 Reducer Conversion Straight Reducer Rod
Service Part Replacement step) Size (in.) (in. wc) Range Thermocouple Bushing Kit Range Bushing Adapter
Standard 3/4 x 3/4 3.5 in. wc 0 to 175 F None Two One None None None
VR8300A4508
(0.87 kPa) (-18 to 79 C)
VR8300A3500 Standard 1/2 x 3/4 3.5 in. wc 0 to 175 F None One One None None None
VR8300A4516 (0.87 kPa) (-18 to 79 C)

Combustion Controls
VR8300A4516 Standard 3/4 x 3/4 3.5 in. wc 0 to 175 F One Two One None None None
(0.87 kPa) (-18 to 79 C)

Residential
VR8204A2076 Standard 1/2 x 1/2 3.5 in. wc 0 to 175 F None None One One One None
(0.87 kPa) (-18 to 79 C)
Standard 1/2 x 1/2 3.5 in. wc -40 to 175 F None None One One One None
VR8204M1091
(0.87 kPa) (-40 to 79 C)
VR8245M2530
VR8205A2024 Standard 1/2 x 1/2 3.5 in. wc 0 to 175 F None None One One One None
(0.87 kPa) (-18 to 79 C)
VR8245M2530 Standard 1/2 x 1/2 3.5 in. wc -40 to 175 F None None One None One None

Hydronic Controls
(0.87 kPa) (-40 to 79 C)
VR8205H1003 Slow 1/2 x 1/2 3.5 in. wc 0 to 175 F None None None None None None
(0.87 kPa) (-18 to 79 C)

VR8345H4555 VR8304H4503 Slow 3/4 x 3/4 3.5 in. wc 0 to 175 F None None One None None None
(0.87 kPa) (-18 to 79 C)
VR8345H4555 Slow 3/4 x 3/4 3.5 in. wc 0 to 175 F None Two One None None None
(0.87 kPa) (-18 to 79 C)
VR8304M3509 Standard 1/2 x 3/4 3.5 in. wc -40 to 175 F None One One None None None
(0.87 kPa) (-40 to 79 C)
VR8304M4507 Standard 3/4 x 3/4 3.5 in. wc -40 to 175 F None Two One None None None

Controls
(0.87 kPa) (-40 to 79 C)

Water
VR8345M4302
VR8305M3506 Standard 1/2 x 3/4 3.5 in. wc -40 to 175 F None One One One None None
(0.87 kPa) (-40 to 79 C)
VR8345M4302 Standard 3/4 x 3/4 3.5 in. wc -40 to 175 F None Two One None None None
(0.87 kPa) (-40 to 79 C)
VR8205Q2555 2-Stage 1/2 x 1/2 1.7 in. wc -40 to 175 F None None One None One None
Low Fire; (-40 to 79 C)

Building Automation
3.5 in. wc
High Fire
VR8304Q4511 2-Stage 3/4 x 3/4 1.7 in. wc -40 to 175 F None Two One None none None
Low Fire; (-40 to 79 C)
3.5 in. wc
High Fire
VR8345Q4563
VR305Q4500 2-Stage 3/4 x 3/4 1.7 in. wc -40 to 175 F None One One None None None
Low Fire; (-40 to 79 C)
3.5 in. wc
High Fire
VR8345Q4563 2-Stage 3/4 x 3/4 1.7 in. wc -40 to 175 F None Two One None None None

Components
Commercial
Low Fire; (-40 to 79 C)
3.5 in. wc
High Fire
VR8200A2124 Standard 1/2 x 1/2 3.5 in. wc 0 to 175 F One None One One One None
(0.87 kPa) (-18 to 79 C)
VR8200A2132 Standard 1/2 x 1/2 3.5 in. wc 0 to 175 F None None One One One None
VR8200A2744 (0.87 kPa) (-18 to 79 C)
Pneumatic Controls

VR8200A2744 Standard 1/2 x 1/2 3.5 in. wc 0 to 175 F None None One One + One None
(0.87 kPa) (-18 to 79 C) One
Elbow
VS820A1054 Standard 3/4 x 3/4 3.5 in. wc 32 to 175 F None Two None None One None
(0.87 kPa) (0 to 79 C)
VS820A1336 Standard 3/4 s 3/x 10.0 in. wc 32 to 175 F None Two None None One None
VS820A1088
(2.49 kPa) (0 to 79 C)
VS820A1088 Standard 3/4 x 3/4 3.5 in. wc 32 to 175 F None Two One None One Yes
(0.87 kPa) (0 to 79 C)
Industrial Combustion

Notes:
All piloted valves have a 1/4 in. compression fitting.
Controls

All the VR valves come set for natural gas, but can be converted to LP gas.
The VS820A1054 is for natural gas. The VS820A1336 is for LP gas.
All the VR valves have inlet and outlet pressure taps. The VS820 valves have just an outlet pressure tap

70-6910 115
Gas Valve Selection Guide

Competitive Replacement
Universal Service
Part Honeywell White-Rodgers Robertshaw
VR8300A4003, VR8300A4011, VR8300A4037, 36C01-405 720-406 (7200ER)
VR8300A4045, VR8300A4557, VR8300A4565
VR8300A3104, VR8300A3120, VR8300A3153, 36C03-300, 36C03-400, 36C03-433, 720-404 (7200ER)
VR8300A4516 VR8300A3161, VR8300A3203, VR8300A3559, 36C03-258
VR8300A3567, VR8300A3575
VR8300A4003, VR8300A4011, VR8300A4037, — 700-400
VR8300A4045, VR8300A4557, VR8300A4565
VR8204A1201, VR8204A1219, VR8204A2001, — —
VR8204A2175, VR8204A2803, VR8300A4565
36E01-204, 36E01-205, 36E01-206, 722-079 (2000IPERHC)
VR8204M1075
VR8245M2530 36E01-305, 36E93-304
— 36G22-214 722-051 (2000DERHC)
VR8205M1106, VR8205M2310, VR8205M2443, 36E36-304, 36E22-214 720-079 (7200IPER), 720-080
VR8205M2450, VR8205M2476 (7200IPER-LP)
VR8205H2605, VR8305H4013, VR8305H4039 — —
VR8204H1006, VR8204H1055 — 720-070 (7200IPER-S7C), 720-071
VR8345H4555 (7200IPER-S7C), 720-072 (7200IPER-
S7C), 720-073 (7200IPER-LP-S7C)
— 36E98-304, 36E24-214, 36E52-214 700-052
— — —
VR8304M4002 — —
VR8345M4302
VR8305M4066, VR8305M4165, VR8305M4231 36G22-214, 36C68-423 720-051 (7200DER)
— 36E36-304, 36C68-423 —
VR8205Q2662, VR8205Q2746, VR8205Q2787, 36E54-214 —
VR8205Q2381

VR8345Q4563 VR8304Q4453 36C76-406, 36C76-420 36C76-463 —


VR8305Q4146 36D13-208, 36D13-405, 36G54-214 —
— 36E96-314 720-082 (7200IPER2-4)
VR8200A2116, VR8200A2264, VR8200A2322* — 720-400 (7200ER), 720-402 (7200ER)
VR8200A2744 VR8200A2116, VR8200A2264, VR8200A2322* — 720-400 (7200ER), 720-402 (7200ER)
VR8200A2322* — —
VS820A1005, VS820A1013, VS820A1047, 36C03U-300, 36C03U-333, 36C03U-400, —
VS820A1278, VS820A5204, VS820A1922 36C03U-433
VS820A1211, VS820A1740, VS820A1120, — —
VS820A1088
VS820A1898, VS820A1872, VS820A1906
VS820A1807, VS820A2003, VS820A1815, — —
VS820A1039, VS820A2011

*Canadian Numbers

For a complete cross-reference, visit www.customer.honeywell.com

116 customer.honeywell.com 70-6910


SmartValve® System Controls
SV9501; SV9502 SmartValve® System

Controls
Home
The SmartValve System Controls provide easy field replacement of
a wide range of SV9500, SV9501, SV9502 and SV9602 SmartValve
System models. Gas appliance manufacturers use these models in
many types of gas fired heating appliances including central
furnaces, residential boilers, rooftop furnaces, commercial
cooking appliances, and unit heaters. These controls provide
intermittent pilot gas ignition sequencing, pilot flame sensing, and

Indoor Air Quality


both pilot and main gas control functions in a single control. They
are directly compatible with the Q3450 or Q3480 Intermittent Pilot
burners used with the original controls on the appliance.
• Suitable for a wide range of gas-fired appliances including residential
furnaces, roof-top furnaces, residential boilers, unit heaters, infrared
heaters, space heaters and commercial cooking units.
• Replaces SV9500, SV9501 and SV9502 controls as noted below.
• Ignition sequence includes timed trial for ignition.

Combustion Controls
Body Pattern: Straight-through Ignition Source: Pilot
Maximum Capacity at 1 in. P.D. 150 ft3/hr (4.2 m3/hr) Ignition System Type: Intermittent Hot Surface Pilot Ignition

Residential
Maximum Capacity: 200 ft3/hr (5.7 m3/hr) Ignition Trial Time: 90 sec
Minimum Capacity: 20 ft3/hr (0.6 m3/hr) Ignition Trials To Lockout: continuous retry
Pilot Gas Outlet: Yes Pressure Ratings: 1/2 psi (3.45 kPa)
Electrical Ratings: 24 Vac Ambient Temperature Range: -40 F to +175 F (-40 C to +79 C)
Frequency: 60 Hz, 50 Hz Typical Ignition Hardware: Q3450
Flame Failure Response Time (sec): 1.6 sec @ 3 µA Approvals:
Flame Sense: Electrode American Gas Association: IAS Design Certified: C2030017
Ignition Sequence: Intermittent Pilot

Hydronic Controls
Opening Pressure Regulator Setting
Type of Characteristics
Product Number Gas (standard, step) Inlet/Outlet Size (in.) (psi) (kPa) PrePurge
SV9501M2528 Natural Standard Opening 1/2 in. NPT x 1/2 in. NPT 0.87 kPa 3.5 in. wc None
SV9501M8129 Natural Fast-Fast Opening 1/2 in. NPT x 1/2 in. NPT 0.87 kPa 3.4 in. wc None
SV9502H2522 Natural Slow Opening 1/2 in. NPT x 1/2 in. NPT 0.80 kPa 3.2 in. wc 15 seconds

Controls
Water
Building Automation
Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 117
SmartValve® System Controls
SV9510 SmartValve® System
combustion air blower. The control also monitors the appliance
airflow proving switch circuit and limit string to assure proper
appliance operation. The SmartValve System Controls provide
prepurge, postpurge and timed trial for ignition with multiple
ignition trials and auto reset from lockout. Diagnostic LED
indicates system status.
• The control communicates directly with the ST9160 Electronic Fan
Timer (EFT) in typical forced warm air furnace applications.
• It will also interface with the 208907 Terminal Board, providing
compatibility with power-stealing thermostats. Or, it directly
interfaces with the appropriate power supplies and a system
thermostat for additional appliance applications.
• When controlled directly by a thermostat, the control does not
provide a postpurge function, as power to the control is removed
The SV9510 SmartValve System Controls combine gas flow control when the thermostat call for heat ends.
and electronic direct main burner ignition sequencing functions • This system is suitable for a wide range of fan-assisted combustion,
into a single unit. The ignition source is 120V hot surface igniter gas-fired appliances including furnaces, rooftop furnaces, boilers,
lighting the main burner flame. Provides all gas ignition safety unit heaters, infrared heaters, water heaters and commercial
functions by controlling gas flow, ignition source, and a 120 Vac cooking appliances.

Dimensions, Approximate: 3.2 in. wide x 4.9 in. high x 4.1 in.long Flame Sense: Two Rod
(81 mm wide x124 mm high x 104 mm long.) Ignition Sequence: 17/27 sec
Body Pattern: Straight-through Ignition System Type: Direct Hot Surface Ignition
Maximum Capacity at 1 in. P.D. 150 ft3/hr (4.2 m3/hr) Ignition Trials To Lockout: 4 trials
Maximum Capacity: 200 ft3/hr (5.7 m3/hr) Pressure Ratings: 1/2 psi (3.5 kPa)
Minimum Capacity: 20 ft3/hr (0.6 m3/hr) Pressure Tapping: 1/8 in. - NPT
Electrical Ratings: 24 Vac Ambient Temperature Range: -40 F to +175 F (-40 C to +79 C)
Frequency: 60 Hz, 50 Hz Mounting: 0 to 90 degrees in any direction from the upright position of
Control Voltage (Thermostat or other call for heat): 24 Vac, 60 Hz. the gas control knob, including vertically.
Flame Failure Response Time (sec): 2 sec @ 5 µA

Pressure Regulator
Opening Setting Ignition
Characteristics Inlet/Outlet Trial
Product Number Type of Gas (standard, step) Size (in.) (psi) (kPa) PrePurge Time Includes
• SV9510K2539 Natural Slow Opening 1/2 in. NPT x 0.87 kPa 3.5 in. wc 15 seconds 9 sec LP Conversion Kit
1/2 in. NPT
• SV9510M2511 Natural Standard Opening 1/2 in. NPT x 0.87 kPa 3.5 in. wc 15 seconds 7 sec LP Conversion Kit
1/2 in. NPT
* TRADELINE models • SUPER TRADELINE models

118 customer.honeywell.com 70-6910


SmartValve® System Controls
SV9520 SmartValve® System

Controls
Home
combustion air blower. The control also monitors the appliance
airflow proving switch circuit and limit string to assure proper
appliance operation. The SmartValve System Controls provide
prepurge, postpurge and timed trial for ignition with multiple
ignition trials and auto reset from lockout. Diagnostic LED
indicates system status.
• The control communicates directly with the ST9160 Electronic Fan

Indoor Air Quality


Timer (EFT) in typical forced warm air furnace applications.
• It will also interface with the 208907 Terminal Board, providing
compatibility with power-stealing thermostats. Or, it directly
interfaces with the appropriate power supplies and a system
thermostat for additional appliance applications.
• When controlled directly by a thermostat, the control does not
provide a postpurge function, as power to the control is removed
The SV9520 SmartValve System Controls combine gas flow control when the thermostat call for heat ends.
• This system is suitable for a wide range of fan-assisted combustion,

Combustion Controls
and electronic direct main burner ignition sequencing functions
into a single unit. The ignition source is 120V hot surface igniter gas-fired appliances including furnaces, rooftop furnaces, boilers,
unit heaters, infrared heaters, water heaters and commercial

Residential
lighting the main burner flame. Provides all gas ignition safety
functions by controlling gas flow, ignition source, and a 120 Vac cooking appliances.

Dimensions, Approximate: 3.2 in. wide x 4.9 in. high x 4.1 in.long Ignition System Type: Direct Hot Surface Ignition
(81 mm wide x 124 mm high x 104 mm long.) Ignition Trial Time: 7 sec
Body Pattern: Straight-through Ignition Trials To Lockout: 4 trials
Maximum Capacity at 1 in. P.D. 150 ft3/hr (4.2 m3/hr) Pressure Ratings: 1/2 psi (3.5 kPa)
Maximum Capacity: 200 ft3/hr (5.7 m3/hr) Pressure Tapping: 1/8 in. - NPT
Minimum Capacity: 20 ft3/hr (0.6 m3/hr) Ambient Temperature Range: 0 F to 175 F (-18 C to +79 C)

Hydronic Controls
Electrical Ratings: 24 Vac Mounting: 0 to 90 degrees in any direction from the upright position of
Frequency: 60 Hz, 50 Hz the gas control knob, including vertically.
Control Voltage (Thermostat or other call for heat): 24 Vac, 60 Hz.
Approvals:
Flame Failure Response Time (sec): 2 sec @ 5 µA Canadian Standards Association: CSA International: 158158-
Flame Sense: Two Rod 10592145
Ignition Sequence: 7/12 sec

Pressure Regulator
Opening Setting
Type of Characteristics
Product Number Gas (standard, step) Inlet/Outlet Size (in.) (psi) (kPa) PrePurge Includes

Controls
Water
• SV9520H8513 Natural Fast-Slow Opening 1/2 in. NPT x 1/2 in. NPT 0.87 kPa 3.5 in. wc 15 seconds LP Conversion Kit
• SV9520M2536 Natural Standard Opening 1/2 in. NPT x 1/2 in. NPT 0.87 kPa 3.5 in. wc 15 seconds LP Conversion Kit
* TRADELINE models • SUPER TRADELINE models

Building Automation
Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 119
SmartValve® System Controls
SV9541 SmartValve® System
functions by controlling gas flow, ignition source, and a 120 Vac or
240 Vac combustion air blower. The controls also monitor the
appliance airflow proving switch and limit string to assure proper
appliance operation, and provide prepurge, postpurge, and timed
trial for pilot ignition with 100 percent shutoff and continuous retry.
A diagnostic LED indicates system status.
• These controls communicate directly with an electronic fan timer
(ST9160 Electronic Fan Timer for single stage applications; ST9162
Electronic Fan Timer for two-stage applications) in typical forced
warm air furnace applications.
• They also interface with the 208907 Terminal Board, providing
compatibility with power stealing thermostats. Or, they directly
interface with the appropriate power supplies and a system
thermostat for additional appliance applications.
• When controlled directly by a thermostat, these controls do not
provide a postpurge function, because power to the control is
The TRADELINEÆ SV9541 SmartValve System Controls combine removed when the thermostat call for heat ends.
gas flow control and electronic intermittent pilot sequencing • The SV9541 Systems are suitable for a wide range of fan-assisted
functions into a single unit. The Q3450 or Q3480 Pilot hardware combustion gas-fired appliances including furnaces, rooftop
supplies the low voltage igniter, flame sensor and pilot burner. furnaces, boilers, unit heaters, infrared heaters, water heaters and
These ignition system controls provide all gas ignition safety commercial cooking appliances.

Dimensions, Approximate: 3.2 in. wide x 4.9 in. high x 4.1 in.long Ignition Source: Pilot
(81 mm wide x 124 mm high x 104 mm long.) Ignition System Type: Intermittent Hot Surface Pilot Ignition
Body Pattern: Straight-through Ignition Trial Time: 90 sec
Maximum Capacity at 1 in. P.D. 150 ft3/hr (4.2 m3/hr) Ignition Trials To Lockout: continuous retry
Maximum Capacity: 200 ft3/hr (5.7 m3/hr) Pressure Ratings: 1/2 psi (3.5 kPa)
Minimum Capacity: 20 ft3/hr (0.6 m3/hr) Pressure Tapping: 1/8 in. - NPT
Pilot Gas Outlet: Yes Ambient Temperature Range: -40 F to +175 F (-40 C to +79 C)
Electrical Ratings: 24 Vac Mounting: 0 to 90 degrees in any direction from the upright position of
Frequency: 60 Hz, 50 Hz the gas control knob, including vertically.
Control Voltage (Thermostat or other call for heat): 24 Vac, 60 Hz. Approvals:
Flame Failure Response Time (sec): 1.6 sec @ 3 µA Canadian Standards Association: CSA-International, Design Certified
Flame Sense: Two Rod
Ignition Sequence: Intermittent Pilot

Pressure Regulator Setting


Type of Opening Characteristics Inlet/Outlet
Product Number Gas (standard, step) Size (in.) (psi) (kPa) PrePurge Includes
• SV9541Q2561 Natural Standard Opening 2-stage 1/2 in. NPT x 0.42 kPa low; 1.7 in. wc low; 15 seconds LP Conversion Kit
1/2 in. NPT 0.80 kPa high 3.2 in. wc high
* TRADELINE models • SUPER TRADELINE models

120 customer.honeywell.com 70-6910


SmartValve® System Controls
SV9601 SmartValve® System

Controls
Home
The SV9601 SmartValve System Controls combine gas flow control
and electronic intermittent pilot sequencing functions into a single
unit. This product family offers several different intermittent pilot
sequences for a wide range of applications. This system is suitable
for application in a wide range of gas-fired appliances including
furnaces, rooftop furnaces, boilers, unit heaters, infrared heaters,
space heaters, water heaters, decorative appliances, and

Indoor Air Quality


commercial cooking units. The specific application of the
SmartValve System is the responsibility of the appliance
manufacturer.

Combustion Controls
Dimensions, Approximate: 3.2 in. wide x 4.9 in. high x 4.1 in.long Ignition Sequence: Intermittent Pilot
(81 mm wide x 124 mm high x 104 mm long.) Ignition Source: Pilot

Residential
Body Pattern: Straight-through Ignition System Type: Intermittent Hot Surface Pilot Ignition
Maximum Capacity at 1 in. P.D. 300 ft3/hr (8.5 m3/hr) Ignition Trial Time: 90 sec
Maximum Capacity: 415 ft3/hr (11.8 m3/hr) Ignition Trials To Lockout: continuous retry
Minimum Capacity: 30 ft3/hr (0.8 m3/hr) Pressure Ratings: 1/2 psi (3.5 kPa)
Electrical Ratings: 24 Vac Pressure Tapping: 1/8 in. - NPT
Frequency: 60 Hz, 50 Hz Ambient Temperature Range: -40 F to +175 F (-40 C to +79 C)
Control Voltage (Thermostat or other call for heat): 24 Vac, 60 Hz. Mounting: 0 to 90 degrees in any direction from the upright position of
Flame Failure Response Time (sec): 1.6 sec @ 3 µA the gas control knob, including vertically.

Hydronic Controls
Flame Sense: Two Rod

Pressure Regulator
Opening Setting
Characteristics Inlet/Outlet
Product Number Type of Gas (standard, step) Size (in.) (psi) (kPa) Includes
• SV9601M4571 Natural Standard Opening 3/4 in. NPT x 0.87 kPa 3.5 in. wc Two 3/4 in. x 1/2 in. reducer bushings and an
3/4 in. NPT. LP conversion kit.
* TRADELINE models • SUPER TRADELINE models

Controls
Water
Building Automation
Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 121
SmartValve® System Controls
SV9602 SmartValve® System
The SV9602 SmartValve System Controls combine gas flow control
and electronic intermittent pilot sequencing functions into a single
unit. This product family offers several different intermittent pilot
sequences for a wide range of applications. This system is suitable
for application in a wide range of gas-fired appliances including
furnaces, rooftop furnaces, boilers, unit heaters, infrared heaters,
space heaters, water heaters, decorative appliances, and
commercial cooking units. The specific application of the
SmartValve System is the responsibility of the appliance
manufacturer.

Dimensions, Approximate: 3.2 in. wide x 4.9 in. high x 4.1 in.long Ignition Source: Pilot
(81 mm wide x 124 mm high x 104 mm long.) Ignition System Type: Intermittent Hot Surface Pilot Ignition
Body Pattern: Straight-through Ignition Trial Time: 90 sec
Maximum Capacity at 1 in. P.D. 300 ft3/hr (8.5 m3/hr) Ignition Trials To Lockout: continuous retry
Maximum Capacity: 415 ft3/hr (11.8 m3/hr) Pressure Tapping: 1/8 in. - NPT
Minimum Capacity: 30 ft3/hr (0.8 m3/hr) Ambient Temperature Range: -40 F to +175 F (-40 C to +79 C)
Electrical Ratings: 24 Vac Mounting: 0 to 90 degrees in any direction from the upright position of
Frequency: 60 Hz, 50 Hz the gas control knob, including vertically.
Control Voltage (Thermostat or other call for heat): 24 Vac, 60 Hz.
Approvals:
Flame Failure Response Time (sec): 1.6 sec @ 3 µA Canadian Standards Association: CSA-International, Design Certified
Flame Sense: Two Rod
Ignition Sequence: Intermittent Pilot

Opening Pressure Regulator Setting


Characteristics Inlet/Outlet
Product Number Type of Gas (standard, step) Size (in.) (psi) (kPa) PrePurge
* SV9602P4816 Natural Step Opening 3/4 in. NPT x Full Rate: 0.87 kPa; Full Rate: 3.5 in. wc; 30 seconds
3/4 in. NPT. Step Setting: 0.17 kPa Step Setting: 0.7 in. wc
* SV9602P4824 Natural Step Opening 3/4 in. NPT x Full Rate: 0.87 kPa; Full Rate: 3.5 in. wc; 30 seconds
3/4 in. NPT. Step Setting: 0.62 kPa Step Setting: 2.5 in. wc
* SV9602P4832 LP Step Opening 3/4 in. NPT x Full Rate: 2.49 kPa; Full Rate: 10.0 in. wc; 30 seconds
3/4 in. NPT. Step Setting: 0.62 kPa Step Setting: 2.5 in. wc
* SV9602P4840 LP Step Opening 3/4 in. NPT x Full Rate: 2.49 kPa; Full Rate: 10.0 in. wc; 30 seconds
3/4 in. NPT. Step Setting: 0.35 kPa Step Setting: 1.4 in. wc
* TRADELINE models • SUPER TRADELINE models

122 customer.honeywell.com 70-6910


SmartValve® System Controls
SV9641 SmartValve® System

Controls
Home
240 Vac combustion air blower. The controls also monitor the
appliance airflow proving switch and limit string to assure proper
appliance operation, and provide prepurge, postpurge, and timed
trial for pilot ignition with 100 percent shutoff and continuous retry.
A diagnostic LED indicates system status.
• These controls communicate directly with an electronic fan timer
(ST9160 Electronic Fan Timer for single stage applications; ST9162

Indoor Air Quality


Electronic Fan Timer for two-stage applications) in typical forced
warm air furnace applications.
• They also interface with the 208907 Terminal Board, providing
compatibility with power stealing thermostats. Or, they directly
interface with the appropriate power supplies and a system
thermostat for additional appliance applications.
• When controlled directly by a thermostat, these controls do not
The TRADELINE® SV9641 SmartValve System Controls combine provide a postpurge function, because power to the control is
gas flow control and electronic intermittent pilot sequencing removed when the thermostat call for heat ends.

Combustion Controls
functions into a single unit. The Q3450 or Q3480 Pilot hardware • The SV9641 Systems are suitable for a wide range of fan-assisted
combustion gas-fired appliances including furnaces, rooftop

Residential
supplies the low voltage igniter, flame sensor and pilot burner.
These ignition system controls provide all gas ignition safety furnaces, boilers, unit heaters, infrared heaters, water heaters and
functions by controlling gas flow, ignition source, and a 120 Vac or commercial cooking appliances.

Dimensions, Approximate: 3.2 in. wide x 4.9 in. high x 4.1 in. long Flame Sense: Two Rod
(81 mm wide x 124 mm high x 104 mm long) Ignition Sequence: Intermittent Pilot
Body Pattern: Straight-through Ignition Source: Pilot
Maximum Capacity at 1 in. P.D. 300 ft3/hr (8.5 m3/hr) Ignition System Type: Intermittent Hot Surface Pilot Ignition
Maximum Capacity: 415 ft3/hr (11.8 m3/hr) Ignition Trial Time: 90 sec

Hydronic Controls
Minimum Capacity: 30 ft3/hr (0.8 m3/hr) Ignition Trials To Lockout: continuous retry
Pilot Gas Outlet: Yes Pressure Ratings: 1/2 psi (3.5 kPa)
Electrical Ratings: 24 Vac Pressure Tapping: 1/8 in. - NPT
Frequency: 60 Hz, 50 Hz Ambient Temperature Range: -40 F to +175 F (-40 C to +79 C)
Control Voltage (Thermostat or other call for heat): 24 Vac Mounting: 0 to 90 degrees in any direction from the upright position of
Flame Failure Response Time (sec): 1.6 sec @ 3 µA the gas control knob, including vertically.

Pressure Regulator
Opening Setting
Type of Characteristics Inlet/Outlet
Product Number Gas (standard, step) Size (in.) (psi) (kPa) PrePurge PostPurge Includes

Controls
Water
• SV9641M4510 Natural Standard Opening 3/4 in. NPT x 0.87 kPa 3.5 in. wc 15 seconds 30 seconds Two 3/4 in. x 1/2 in. reducer
3/4 in. NPT. bushings and an LP conversion kit.
* TRADELINE models • SUPER TRADELINE models

Building Automation
Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 123
SmartValve® Selection Guide
SmartValve® Control Systems Selection Guide
Cross-
Specifications Reference

3/4 in. x 1/2 in.


Ambient Natural to LP Reducer Extension
Ignition/ Universal Opening Temperature Conversion Kit Bushings Harness
Application Service Part Gas Type Characteristics Range (Included (Included) (Included) OEM Brands Replaces
SV9570A2054,
SV9570A2518 Natural A.O Smith SV9570A2070,
HSI Water Standard 0 to 150 F SV9570A2096
No None No
Heaters Opening (-18 to 66 C) SV9570A2062,
SV9570A2526 LP A.O. Smith SV9570A2088,
SV9570A2187
ICP, Heil,
Tempstar,
SV9541Q2561 2-Stage Yes None SV9540Q2464,
Arcoaire,
SV9541Q3098
Intermittent HSI Comfortmaker,
Pilot with KeepRite
Combustion Air SV9541M2094,
Control and -40 to 175 F ICP, Heil,
Natural No Tempstar, SV9540M2229,
Limit (-40 to 79 C) SV9540M2260,
Monitoring Arcoaire,
Standard Comfortmaker, SV9640M4116,
Forced Air SV9641M4510 Yes Two SV9640M4124,
Furnace Opening KeepRite,
Mestek, Sant SV9540M2278,
Fin SV9540M2245,
SV9640M3126,
SV9640M4132
SV9510M2347,
SV9510M2362,
SV9410M2902,
SV9510M2511 -40 to 175 F SV9510M2412,
Modine
(-40 to 79 C) SV9510M2354,
Standard SV9410M2910,
Opening SV9510M2388,
SV9510M2420
SV9420M2331,
Direct Ignition, SV9520M2536 -40 to 175 F
(-40 to 79 C) — SV9520M2403,
General Natural Yes None No SV9420M2323
Application
SV9510H2228,
-40 to 175 F Roberts SV9510K2133,
SV9510K2539 Slow Opening (-40 to 79 C) Gordon SV9510K2158,
SV9510K2141,
SV9510K2166

Armstrong, SV9520H8042,
Fast-Slow 0 to 175 F SV9520H8034,
SV9520H8513 Concord,
Opening (-18 to 79C) AirEase SV9520H8067,
SV9520H8026

124 customer.honeywell.com 70-6910


SmartValve® Selection Guide

Controls
Cross-

Home
Specifications Reference

3/4 in. x 1/2 in.


Ambient Natural to LP Reducer Extension
Ignition/ Universal Opening Temperature Conversion Kit Bushings Harness
Application Service Part Gas Type Characteristics Range (Included (Included) (Included) OEM Brands Replaces
SV9601M4167,
SV9601M4571 Two — SV9601M3003,

Indoor Air Quality


SV9601M4225
SV9501M2056,
SV9501M2080,
SV9501M2726,
Standard ICP, Heil, SV9501M2031,
-40 to 175 F No
Opening Tempstar, SV9501M2049,
(-40 to 79C)
SV9501M2528 Arcoaire, SV9501M2239
Comfortmaker, SV9501M2700,
KeepRite SV9501M2718,
Yes SV9501M2734,

Combustion Controls
SV9501M2742,
None SV9501M2064

Residential
SV9501M8129 Fast-Fast — SV9501M8103
SV9501H3415,
Laars, Utica, SV9501H2417,
Yes SV9501H2409,
0 to 175 F Armstrong,
SV9502H2522 Slow Opening SV9502H1706,
Intermittent HSI (-18 to 79) Concord,
AireEase SV9502H2704,
Pilot, General Natural SV9501H3423,
Application SV9501H2425

Hydronic Controls
Burnham, ICP, SV9501P2004,
Heil, Tempstar, SV9601P4107,
SV9602P4816 Arcoaire, SV9501P2053,
Comfortmaker, SV9502P2101,
KeepRite SV9602P4105
SV9501P2087,
SV9601P4172,
SV9602P4824 Burnham
SV9502P2127,
-40 to 175 F SV9602P4121
Step Opening None Two Yes
(-40 to 79 C) SV9501P2020,
SV9501P2046,
SV9601P4149,

Controls
SV9602P4832 Burnham SV9601P4164,

Water
SV9502P2119,
SV9502P2135,
SV9602P4113,
SV9602P4139
SV9602P4840 — SV9601P4115

Building Automation
For a complete cross-reference, visit www.customer.honeywell.com

Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 125
Gas Valves Parts and Accessories
Parts and Accessories for Combination Gas Controls
Product Number Description Used With
386449 Compression fitting for 1/4 inch OD pilot All Honeywell Combination Gas Controls
tubing, 0.65 inch total overall length
386449-1 Compression fitting for 1/4 inch OD pilot All Honeywell Combination Gas Controls
tubing, 0.78 inch total overall length
386449-4 Compression fitting for 1/4 inch OD pilot All Honeywell Combination Gas Controls
tubing, 1.15 inch total overall length

390427A 3/4 inch x 1/2 inch reducer bushing for valves All Honeywell Combination Gas Controls
390427B 1/2 inch x 3/8 inch reducer bushing for valves All Honeywell Combination Gas Controls
390427D Envelope Assembly, includes one each of 3/ All Honeywell Combination Gas Controls
4 inch x 1/2 inch, 1/2 inch x 3/8 inch, 3/4 inch
x 3/8 inch reducer bushing
390427E Envelope Assembly, includes two 3/4 in. NPT All Honeywell Combination Gas Controls
x 1/2 in. NPT reducer bushings

391936 LP to Natural Gas Conversion kit, including V800, VS821, VS820


regulator spring, O-ring, screw and cap

391937 Natural Gas to LP Conversion kit, including V800, VS821, VS820


regulator spring, O-ring, screw and cap

392449 Compression fitting for 1/8 inch OD pilot VR8200, VR8300


tubing, 0.65 inch total overall length
392449-1 Compression fitting for 1/8 inch OD pilot VR8200, VR8300
tubing, 0.78 inch total overall length
392449-4 Compression fitting for 1/8 inch OD pilot VR8200, VR8300
tubing, 1.15 inch total overall length
392451-1 ECO (energy cutoff) connector for 1/4 inch (6 V800, VS821, VS820
mm) quick-connects

392877 1/4 inch barbed vent fitting VR8200, VR8300


393200-1 ECO connector bag assembly, includes ECO VR8200, VR8300, VR4200, VR4300
adapter with 1/4 inch (6 mm) quick-connects

393690-11 Flange Kit bag assembly, includes 3/8 inch VR8200, VR8300, VR4200, VR4300,
straight flange, O-ring, 9/64 inch hex screws SV9500, VR8305, VR4204, VR4304,
and 9/64 inch hex wrench VR4305, VR8204, VR8205, VR8304

126 customer.honeywell.com 70-6910


Gas Valves Parts and Accessories

Controls
Product Number Description Used With

Home
393690-13 Flange Kit bag assembly, includes 1/2 inch VR8200, VR8300, VR4200, VR4300,
angle flange, O-ring, 9/64 inch hex screws SV9500, VR8305, VR4204, VR4304,
and 9/64 inch hex wrench VR4305, VR8204, VR8205, VR8304

Indoor Air Quality


393690-4 Flange Kit bag assembly, includes 3/4 in. VR8200, VR8300, VR4200, VR4300,
straight flange, O-ring, and hex screws. SV9500, VR8305, VR4204, VR4304,
VR4305, VR8204, VR8205, VR8304

Combustion Controls
Residential
393691 Natural Gas to LP Conversion kit, including VR8200, VR8300, VR4200, VR4300,
regulator spring, screw and cap SV9500, VR8305, VR4204, VR4304,
VR4305, VR8204, VR8205, VR8304

Hydronic Controls
394537 1/8 inch barbed vent fitting VR8200, VR8300, VR4200, VR4300,
SV9500, VR8305, VR4204, VR4304,
VR4305, VR8204, VR8205, VR8304

Controls
Water
Building Automation
394588 LP to Natural Gas Conversion kit, including VR8200, VR8300, VR4200, VR4300,
regulator spring, screw and cap SV9500, VR8305, VR4204, VR4304,
VR4305, VR8204, VR8205, VR8304
396021 2 Stage LP Conversion Kit VR8305, VR8204, VR8205, VR8304,
SV9540

396025 2 Stage LP to Nat. Conversion Kit SV9540, VR8305, VR8204, VR8205,


VR8304

Components
Commercial
396087-1 Natural Gas Conversion Kit VS8510, VS8410, VS8420, VS8520

396087-2 LP Gas Conversion Kit VS8510, VS8410, VS8420, VS8520


Pneumatic Controls
Industrial Combustion
Controls

70-6910 127
Thermocouples and Thermopiles
Q313 Replacement Thermopile Generators
Q313 Thermopile Generator contains multiple thermocouples
connected in series to increase the millivoltage output. The power
generated is sufficient to operate an automatic millivolt gas control
system, independent of any outside power source.
• Push-in clip, split nut, and adapter assembly for easy pilot burner
installation.
• Spade or quick-connect terminals available for millivolt gas control
connections.
• Male nut connector for Pilotstat® safety control power units.
• Available in a variety of lead lengths.

Open Circuit Output: 600 mV to 750 mV


Voltage: 750 mV
Temperature Ratings Cold Junction: 780 F (416 C)
Temperature Ratings Hot Junction: 1400 F (760 C)
Connection Type: Spade Terminals

Lead Length
Product Number (inch) (mm) Resistance Includes Used With
Q313A1022 35 in. 889 mm 2.89 ohms 1/2 in. thermopile attaching nut Q314, Q324, Q327, Q377, Q379, Q382 Pilot Burners
Q313A1055 47 in. 1194 mm 2.90 ohms 1/2 in. thermopile attaching nut. Q314, Q324, Q327, Q377, Q379, Q382 Pilot Burners
* Q313A1139 35 in. 889 mm 2.89 ohms push-in clip Q314, Q324, Q327, Q377, Q379, Q382 Pilot Burners
* Q313A1170 35 in. 889 mm 2.89 ohms PG9 adapter (part no. 393948) and 1/2 in. Q314, Q324, Q327, Q377, Q379, Q382 Pilot Burners
thermopile attaching nut
* Q313A1188 35 in. 889 mm 2.89 ohms push-in clip, 1/2 in. thermopile attaching Q314, Q324, Q327, Q377, Q379, Q382 Pilot Burners
nut.
Q313A1402 35 in. 889 mm 2.89 ohms PG9 adapter (part no. 393948) and 1/2 in. Q314, Q324, Q327, Q377, Q379, Q382 Pilot Burners
thermopile attaching nut
Q313B1005 35 in. 889 mm 2.89 ohms Junction box for series hookup with high Q314, Q324, Q327, Q377, Q379, Q382 Pilot Burners
limit switch and 1/2 in. thermopile attaching
nut
* TRADELINE models • SUPER TRADELINE models

Q340 Universal 30 mV Thermocouple


Thermocouples generate a thermoelectric current that senses a
pilot flame on gas-fired heating systems. The pilot flame heats the
tip of the thermocouple, producing a temperature differential
between it and the base. This temperature difference generates a
small amount of DC power, measured in millivolts.
• Push-in clip, split nut, and adapter assembly for easy pilot burner
installation.
• Spade or quick-connect terminals available for millivolt gas control
connections.
• Male nut connector for Pilotstat® safety control power units.
• Available in a variety of lead lengths.

Open Circuit Output: 26 mV to 32 mV


Voltage: 30 mV
Temperature Ratings Cold Junction: 780 F (416 C)
Temperature Ratings Hot Junction: 1400 F (760 C)

Lead Length
Product Number (inch) (mm) Connection Type Resistance Includes Used With
* Q340A1066 18 in. 457 mm 11/32 32 Male Connector Nut 0.02 ohms Adapter and Push In Clip —
• Q340A1074 24 in. 610 mm 11/32 32 Male Connector Nut; 0.02 ohms Adapter and Push In Clip —
Push-in Clip
* Q340A1082 30 in. 762 mm 11/32 32 Male Connector Nut 0.02 ohms Adapter and Push In Clip —
• Q340A1090 36 in. 914 mm 11/32 32 Male Connector Nut 0.02 ohms Adapter and Push In Clip —
* Q340A1108 48 in. 1219 mm 11/32 32 Male Connector Nut 0.03 ohms Adapter and Push In Clip —
Q340A1504 18 in. 457 mm Push-in Clip 0.02 ohms Adapter and Push In Clip Q303,Q308,Q314,Q324,Q333
Q340A1512 24 in. 610 mm 11/32 32 Male Connector Nut 0.02 ohms Adapter and Push In Clip Q314
Q340A1520 30 in. 762 mm Push-in Clip 0.02 ohms Adapter and Push In Clip Q303,Q308,Q314,Q324,Q335
Q340A1538 36 in. 914 mm 11/32 32 Male Connector Nut 0.02 ohms Adapter and Push In Clip Q314
Q340A1546 48 in. 1219 mm Push-in Clip 0.03 ohms Adapter and Push In Clip Q303,Q308,Q314,Q324,Q337
* TRADELINE models • SUPER TRADELINE models

128 customer.honeywell.com 70-6910


Thermocouples and Thermopiles
Q390 Thermocouple

Controls
Home
Thermocouples generate a thermoelectric current that senses a
pilot flame on gas-fired heating systems. The pilot flame heats the
tip of the thermocouple, producing a temperature differential
between it and the base. This temperature difference generates a
small amount of DC power, measured in millivolts.
• Push-in clip, split nut, and adapter assembly for easy pilot burner
installation.

Indoor Air Quality


• Spade or quick-connect terminals available for millivolt gas control
connections.
• Male nut connector for Pilotstat® safety control power units.
• Available in a variety of lead lengths.
Open Circuit Output: 26 mV to 32 mV Temperature Ratings Cold Junction: 780 F (416 C)
Voltage: 30 mV Temperature Ratings Hot Junction: 1400 F (760 C)

Combustion Controls
Lead Length
Product Number (inch) (mm) Connection Type Resistance Includes

Residential
* Q390A1046 24 in. 610 mm 11/32 32 Male Connector Nut 0.02 ohms Adapter and Push In Clip
* Q390A1053 30 in. 762 mm 11/32 32 Male Connector Nut 0.02 ohms Adapter and Push In Clip
* Q390A1061 36 in. 914 mm 11/32 32 Male Connector Nut 0.02 ohms Adapter and Push In Clip
* Q390A1095 18 in. 457 mm 11/32 32 Male Connector Nut 0.02 ohms Adapter and Push In Clip
* Q390A1103 48 in. 1219 mm 11/32 32 Male Connector Nut 0.03 ohms Adapter and Push In Clip

Hydronic Controls
* TRADELINE models • SUPER TRADELINE models

Thermocouple and Thermopile Accessories


Product Number Description
393948 PG9 Adapter Assembly

Controls
Water
394530 Thermocouple Tester Assembly

Building Automation
Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 129
Thermopiles and Thermocouples Selection Guide
Thermopiles/Thermocouples
Contractors depend on Honeywell for easy installation and reliable
performance. Built for long service life, the Honeywell Q313A,
Q340A and Q390A will meet your service needs.
When selecting a thermocouple or thermopile for your next job, look for
these Honeywell features:
• Variety of lead lengths
• Easy installation
• Many accessories included
• Durability

Thermopiles and Thermocouples Selection Guide


Thermocouples
Lead Length Canada US Super Johnson
(in.) Tradeline Tradeline Tradeline White-Rodgers Robertshaw Husky Controls
18 Q340A1405 Q340A1066/U Q390A1095/U H06E-518, H06E-18 — K16BT-18 K19AT-18
24 Q340A1413 Q340A1074/U Q390A1046/U H06E-524, H06E-24 1970-24, 1980-24 K16BT-24 K19AT-24
30 Q340A1421 Q340A1082/U Q390A1053/U H06E-530, H06E-30 1970-30 K16BT-30 K19AT-30
36 Q340A1439 Q340A1090/U Q370A1061/U H06E-536, H06E-36 1970-36, 1980-36 K16BT-36 K19AT-36
48 Q340A1447 Q340A1108/U Q390A1103/U H06E-548, H06E-48 — K16BT-48 K19AT-48

Thermopiles
Model Item Lead Length (in.) Connections Tradeline/Super Tradeline Notes
Q313A1022/U 35 Nut & Spade Terminal Tradeline —
Q313A1139/U 35 Clip & Spade Terminal Super Tradeline Push-In Clip
Q313A1170/U 35 Clip & Spade Terminal Super Tradeline PG9 Adapter (393948)
Q313
Q313A1188/U 35 Nut & Spade Terminal Super Tradeline Push-In Clip, 1/2 in. Attaching Nut
Q313A1055/U 47 Nut & Spade Terminal Tradeline 1/2 in. Attaching Nut
Q313A1105/B 75 Nut & Spade Terminal Tradeline 1/2 in. Attaching Nut

130 customer.honeywell.com 70-6910


Pilot Burners
Q314 Pilot Burner

Controls
Home
Nonprimary-aerated, insert orifice type pilot burner for main burner
ignition with Q340 or Q390 Thermocouple for Pilotstat safety
control operation.
• Use with Q313 Thermopile Generator for 750 mV powerpile
applications.
• Variety of mounting brackets available.
• Variety of tip styles to provide desired flame pattern.

Indoor Air Quality


• Interchangeable, color-coded orifice and inlet fittings can be ordered
to convert between natural and LP gas.
• Single tip style.

Combustion Controls
Dimensions in inches (millimeters)

Residential
1-1/2 (38)
15/32 (12) 1-1/2 (38)
3/8
3/8 MOUNTING (10) 11/16
(10) 3/4 HOLES (2) (17)
(19) TAP 10-32

Hydronic Controls
13/16
(21)
BLEED CLIP BLEED CLIP
OPTIONAL OPTIONAL

1-9/16
1-3/8 (39) 15/32
(35) 7/8 (12) 7/8
(22) 1-3/16 (22)
1-3/32
(30)
(27) 5/8
1/2
(16) (13)

Controls
MOUNTING

Water
HOLES (2)
11/64 (4) DIA. 13/32 25/32
MOUNTING 5/8
HOLES (2) (16) (10) (20) M16556A
TAP 10-32 1-5/32 (29) M16555A
Type of Gas: Natural
Aeration: Non-primary
Approvals:

Building Automation
American Gas Association: IAS Certified File No. L2025001

Compression Mounting Direction of


Product Number Fitting Size Bracket Tip Style Front Tip Orifice Includes
Q314A3513 1/4 in. A Single (F) Front BCR-18 (0.018 in.) —
Q314A3547 1/4 in. A Single (L) Left BCR-18 (0.018 in.) —
• Q314A4586 1/4 in. B Single (F) Front BBR-10 (0.010 in.); Special mounting bracket with screws to
BCR-18 (0.018 in.) convert "B" bracket to "A" bracket.
* Q314A6094 1/4 in. B Single (L) Left BBR-10 (0.010 in.); Special mounting bracket with screws to

Components
Commercial
BCR-18 (0.018 in.) convert "B" bracket to "A" bracket.
* Q314A6102 1/4 in. B Single (K) Right BBR-10 (0.010 in.); Special mounting bracket with screws to
BCR-18 (0.018 in.) convert "B" bracket to "A" bracket.
* TRADELINE models • SUPER TRADELINE models
Pneumatic Controls
Industrial Combustion
Controls

70-6910 131
Pilot Burners
Q327 Pilot Burner
Primary-aerated, spud orifice-type pilot burner for main burner
ignition with Q340 or Q390 Thermocouple for Pilotstat safety
control operation.
• Use with Q313 Thermopile Generator for 750 mV powerpile
applications.
• Variety of mounting brackets available.
• Variety of tip styles to provide desired flame pattern.
• Interchangeable, color-coded orifice and inlet fittings can be ordered
to convert between natural and LP gas.
• Batwing tip style.

Dimensions in inches (millimeters)


Type of Gas: Natural; LP
Aeration: Primary
Approvals:
Q309 American Gas Association: IAS Certified File No. L2025001
Q310
Q313 1-3/4
(44)
1-1/2 (38) 1-5/8
(41)

1/2 (13)
1-3/16
(30)
1/2 (13)

3/16 (5)
1

1-9/16 (40)

1 MOUNTING HOLES ARE 10-32 TAP. M16554A

Product Number Compression Fitting Size Mounting Bracket Tip Style Orifice
* Q327A1626 1/4 in. B Batwing K14 (0.014 in.)A26 (0.026 in.)
* TRADELINE models • SUPER TRADELINE models

132 customer.honeywell.com 70-6910


Pilot Burners
Q345 Igniter-Burner

Controls
Home
Nonprimary-aerated combination pilot burner and ignitor. Used
with the S86, S860, S8610, or S8670 in intermittent pilot systems.
• Includes pilot burner with bracket, ceramic-insulated Kanthal flame
rod/spark igniter and ground strap.
• Single tip style.

Indoor Air Quality


Combustion Controls
Dimensions in inches (millimeters)
Type of Gas: Natural

Residential
9/16 Aeration: Non-primary
1/8 (3)
(14) Leadwire Temperature Ratings: (Max. at electrode tip: 968 C)
Accessories:
390686-1 LP Orifice for Q314, Q345, Q3450, Q3451, Q3452 Pilot
Burners. Orifice stamped: BBR10
1-3/16

Hydronic Controls
(30)
1/2 (13)

Controls
Water
M16560A

Compression Compression Mounting Direction of


Product Number Fitting Length Fitting Size Bracket Tip Style Front Tip Orifice Includes

Building Automation
* Q345A1305 0.78 in. 1/4 in. B Single (F) Front BCR-18 (0.018 in.) Special mounting bracket with screws
to convert "B" bracket to "A" bracket.
* Q345A1313 0.78 in. 1/4 in. B Single (L) Left BCR-18 (0.018 in.) Special mounting bracket with screws
to convert "B" bracket to "A" bracket.
* Q345A1321 0.78 in. 1/4 in. B Single (K) Right BCR-18 (0.018 in.) Special mounting bracket with screws
to convert "B" bracket to "A" bracket.
* TRADELINE models • SUPER TRADELINE models

Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 133
Pilot Burner Parts and Accessories
Residential Combustion Pilot Burner Accessories
Product Number Description
392431 Pilot Hardware for Y8610

Residential Combustion Pilot Burner Parts


Product Number Description Used With
Q3400A1024 30 in. Igniter Flame Rod Assembly SV9500, SV9600, Field
replacement for
Q3450, Q3480 hot
surface pilot burner

Q3400A1081 36 in. Igniter Flame Rod Assembly SV9500, SV9600, Field


replacement for
Q3450, Q3480 hot
surface pilot burner

388146AG Natural Gas Orifice for Q327 Pilot Burner. Orifice is stamped: A 26 Q327

388146KP LP Orifice for Q348 and Q3480 Pilot Burners. Orifice is stamped: KR 14 Q348; Q3480

388146KR LP Orifice for Q327 Pilot Burner. Orifice stamped: K14 Q327

388146NE Natural Gas Orifice for Q348 and Q3480 Pilot Burners. Orifice stamped: Q348; Q3480
NE22

388256B Orifice Assembly: Orifice stamped: 9 CS82

388468H LP Orifice for Q324 Pilot Burners. Orifice stamped: N18 Q324

134 customer.honeywell.com 70-6910


Pilot Burner Parts and Accessories

Controls
Product Number Description Used With

Home
390686-1 LP Orifice for Q314, Q345, Q3450, Q3451, Q3452 Pilot Burners. Orifice Q314; Q345; Q3450;
stamped: BBR10 Q3451; Q3452
390686-23 0.008 LP Pilot Orifice for Q350, Q380. Orifice stamped: GAF8 Q350, Q380
390686-25 0.012 LP Pilot Orifice for Q345 and Q379. Orifice stamped BBR12 Q345, Q379
390686-36 LP Orifice for Q314, Q345, Q3450, Q3451, Q3452 Pilot Burners. Orifice Q314; Q345; Q3450;

Indoor Air Quality


stamped: BBR11 Q3451; Q3452
390686-4 Natural Gas Orifice for Q314, Q345, Q382, Q3450, Q3451, Q3452 pilots Q314; Q345; Q3450;
burners. Orifice stamped: BCR18 Q3451; Q3452; Q382
390686-5 Natural Gas Orifice for Q314, Q345, Q382, Q3450, Q3451, Q3452 pilot Q314; Q345; Q3450;
burners. Orifice stamped: BCR20 Q3451; Q3452; Q382
391959A1 BBR10, Replacement Orifice Assembly 388146AA (A11) —

Combustion Controls
Residential
391959A2 BCR18, Replacement Orifice Assembly 388146AC (A18) —

391959A4 CAR24, Replacement Orifice Assembly 388146JE (A18) —

Hydronic Controls
Controls
Water
Building Automation
Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 135
Ignition Pilot Modules
S87 Direct Spark Ignition Modules
Provide electronic control of direct spark ignition systems used on
gas fire furnaces, boilers, and other heating appliances.
• Control ignition sequence and gas control operation.
• Generate high voltage potential for main burner ignition.
• Lockout after one trial for ignition if main burner fails to ignite.
• Reset from thermostat after lockout.
• Use modules (except S87C) with any combination gas control
designed for direct spark applications and rated 2.0A or less.

Application: Provide electronic control of direct spark ignition systems Ignition Sequence: Single trial for main burner ignition (then shut down
used on gas fired furnaces, boilers, and other heating appliances. and lockout)
Dimensions, Approximate: 5 1/4 in. high x 4 1/16 in. wide x 1 15/16 in. Ignition Source: Internal high voltage spark generator
long (133 mm high x 103 mm wide x 49 mm deep) Ignition System Type: Direct Spark Ignition
Type of Gas: Natural or LP Maximum Valve Load @ 24 Vac (Amps): 2A
Electrical Ratings: 24 Vac Typical Gas Control: VR8205, VR8305
Frequency: 60 Hz Typical Ignition Hardware: Q347A
Flame Failure Response Time (sec): 0.8 sec. @ 5.0 microamp Maximum Ambient Temperature: -40 F to +175 F (-40 C to +79 C)
Flame Failure Re-ignition Time (sec): 0.8 sec. maximum

Product Number Flame Sense Ignition Trial Time (sec) Ignition Trials To Lockout PrePurge Includes
S87B1008 Single Rod 6 sec. 1 None Alarm terminal
S87B1016 Single Rod 11 sec. 1 None Alarm terminal
S87B1024 Single Rod 21 sec. 1 None Alarm terminal
S87B1065 Single Rod 4 sec. 1 None Alarm terminal
S87C1006 Two Rod 6 sec. 1 None —
S87C1030 Two Rod 21 sec. 1 None —
S87D1004 Two Rod 6 sec. 1 None Alarm terminal
S87D1012 Two Rod 11 sec. 1 None Alarm terminal
S87D1020 Two Rod 4 sec. 1 None Alarm terminal
S87D1038 Two Rod 21 sec. 1 None Alarm terminal
S87J1026 Single Rod 11 sec. 1 30 sec. minimum —
S87J1034 Single Rod 21 sec. 1 30 sec. minimum —
S87K1008 Two Rod 4 sec. 1 30 sec. minimum —

136 customer.honeywell.com 70-6910


Ignition Pilot Modules
S89C Hot Surface Ignition Module

Controls
Home
Provide operating control and system shutdown on loss of main
burner flame in direct ignition central heat furnaces and heating
appliances with hot surface igniter.
• S89C,G,J are for systems with a combination igniter- sensor.
• S89C lock out after one try for ignition. S89G,H provide three tries for
ignition before lockout, with 30 sec. min. purge before second and
third tries.

Indoor Air Quality


• Compatible with Norton 201 and 271 or equivalent hot surface
igniters.
• Available with leadwires for line voltage connections.
• Modules can be used on either natural or LP gas; they provide 100
percent shutoff of gas on lockout.
• Modules have relay contacts for use with any direct ignition gas
control with max. 2.0 A, 24 Vat rating.
• Modules use rectification principle for flame sensing. -40 F to +175 F
(-40 C to +79 C) temperature rating.

Combustion Controls
Application: Provide electronic control of direct hot surface ignition Ignition Source: Line Voltage (120 VAC) Hot Surface Element (Norton

Residential
systems used on gas fired furnaces, boilers, and other heating Model 201)
appliances. Ignition System Type: Direct Hot Surface Ignition
Dimensions, Approximate: 5 1/4 in. high x 4 1/16 in. wide x 1 15/16 in. Maximum Valve Load @ 24 Vac (Amps): 2A
long (133 mm high x 103 mm wide x 49 mm deep) Typical Gas Control: VR8205, VR8305
Type of Gas: Natural or LP Typical Ignition Hardware: Norton 201
Electrical Ratings: 24 Vac Maximum Ambient Temperature: -40 F to +175 F (-40 C to +79 C)
Frequency: 60 Hz
Approvals:
Flame Failure Response Time (sec): 2.0 sec. @ 2.5 microamp

Hydronic Controls
Canadian Standards Association: Design Certified
Ignition Sequence: Single trial for main burner ignition (then shut down
and lockout)

Product Number Flame Sense Ignition Trial Time (sec) Ignition Trials To Lockout PrePurge
S89C1087 Single Rod 6 sec. 1 None
S89C1095 Single Rod 15 sec. 1 None

S89E,F Direct Spark Ignition Modules

Controls
Water
Provide electronic control of direct spark ignition systems, with
external spark transformers, used on gas-fired furnaces, boilers,
conversion burners and other heating appliances.
• Controls ignition sequence and gas control operation in direct spark
ignition systems.
• Control separate 120 Vac spark generator that provides high voltage
potential for main burner ignition.

Building Automation
• Lockout after one trial for ignition if main burner fails to ignite.
• Reset from thermostat after lockout. Use separate electrodes for
spark ignition and flame sensing.
• Use any 24 Vac combination gas control designed for direct spark
applications and rated at 2.0A or less.

Application: Provide electronic control of direct spark ignition systems Ignition Source: External (120 VAC powered) High Voltage Spark
used on gas fired furnaces, boilers, and other heating appliances. Generator

Components
Commercial
Dimensions, Approximate: 5 1/4 in. high x 4 1/16 in. wide x 1 15/16 in. Ignition System Type: Direct Spark Ignition
long (133 mm high x 103 mm wide x 49 mm deep) Maximum Valve Load @ 24 Vac (Amps): 2A
Type of Gas: Natural or LP Typical Gas Control: VR8205, VR8305
Electrical Ratings: 24 Vac Typical Ignition Hardware: Q652, Q345
Frequency: 60 Hz Maximum Ambient Temperature: -40 F to +175 F (-40 C to +79 C)
Flame Failure Response Time (sec): 2.0 sec. @ 2.5 microamp
Approvals:
Flame Failure Re-ignition Time (sec): 0.8 sec. maximum Canadian Standards Association: Design Certified
Ignition Sequence: Single trial for main burner ignition (then shut down
Pneumatic Controls

and lockout)

Product Number Flame Sense Ignition Trial Time (sec) Ignition Trials To Lockout PrePurge
S89E1058 Two Rod 4 sec. 1 —
S89F1098 Two Rod 4 sec. 1 30 sec. minimum
S89F1106 Two Rod 4 sec. 1 30 sec. minimum
Industrial Combustion
Controls

70-6910 137
Ignition Pilot Modules
S8610U Universal Intermittent Pilot Module
Field service replacement for most Honeywell, Robertshaw,
Johnson, and UTEC (HSC) Intermittent Pilot Ignition Modules.
Provides electronic control of most intermittent pilot ignition
systems used on gas-fired furnaces, boilers, and other heating
appliances.
• Provides ignition sequence, flame monitoring and safety shutoff for
intermittent pilot central furnaces and heating appliances.
• Provides 100 percent pilot gas shutoff if pilot fails to light; after 6-
minute delay, trial for ignition is repeated. Ignition trial/delay
sequence is repeated until the appliance lights or call for heat is
removed.
• For use with Natural or LP gas.
• For use in single rod or dual rod/remote sense applications. Includes
relay contacts for use with any intermittent pilot gas control string
with maximum 1.0A pilot or 2.0A main valve rating; Honeywell
VR8204, VR8304 or VR8345M combination gas control
recommended.
• Functional equivalent of S86, S8600, S8610 and S90 modules.
• Includes spark cable adapters to allow field replacement of both
Honeywell and competitive controls without replacing existing spark
cable.

Application: One or Two Rod Intermittent Pilot Control with continuous Maximum Valve Load @ 24 Vac (Amps): 1A Pilot, 2A Main @ 165 F;
retry trial time with configurable lockout timing of 15 or 90 seconds and 1A Pilot, 1A Main @ 175 F
configurable prepurge of 30 seconds or no prepurge Typical Gas Control: VR8204, VR8304
Dimensions, Approximate: 3 15/16 in. high x 5 7/16 in. wide x 2 5/8 in. Typical Ignition Hardware: Q345, Q3451, Q3452
deep (100 mm high x 138 mm wide x 67 mm deep) Maximum Ambient Temperature: -40 F to +165 F (-40 C to +74 C)
Type of Gas: Natural or LP Approvals:
Electrical Ratings: 24 Vac Canadian Standards Association: Design Certified
Frequency: 60 Hz; 50 Hz
Flame Failure Response Time (sec): 2 seconds maximum Accessories:
Ignition Sequence: Continuous retry, after trial for ignition, pilot gas 394800-30 30 in. Ignition Cable with Right Angle Boot for use with
shuts off for 5 minutes, then another trial for pilot ignition takes place S8600 family
Ignition Source: Internal high voltage spark generator 394801-30 30 in. Ignition Cable Assembly with straight boot for use with
Ignition System Type: Intermittent Pilot S8600 family

Ignition Trial Between Trial Ignition Trials


Product Number Flame Sense Time (sec) Time (sec) To Lockout PrePurge Includes
• S8610U3009 Single Rod or continuous 5 minute delay after continuous retry Configurable to 30 Damper connection with
Two Rods retry failed trial for ignition. seconds or no prepurge automatic vent damper plug
* TRADELINE models • SUPER TRADELINE models

138 customer.honeywell.com 70-6910


Ignition Pilot Modules
S8910 Universal Hot Surface Ignition Module

Controls
Home
Universal Hot Surface Ignition Module is designed to provide easy
field replacement of a wide range of hot surface ignition modules
manufactured by Honeywell, Robertshaw and White-Rodgers. The
S8910U Module provides operating control of a direct ignition
system using a 120 Vac hot surface igniter.
• Replaces many White-Rodgers, Robertshaw and Honeywell hot
surface ignition models.

Indoor Air Quality


• For 120 Vac (up to 5.0A) surface igniter (Norton 201/271 or
equivalent).
• For local (single rod) or remote (dual rod) rectification type flame
sensing.
• Contains easy-to-use instructions plus the accessories required to
adapt the existing hot surface ignition module.
• Provides one or three ignition trials (four-second or seven-second
trials) per call for heat; prepurge of 32 seconds or less; up to 96
seconds between purge trial times.

Combustion Controls
• Temperature range is -40 to +175 F (-40 to +79 C).

Residential
Application: Provide electronic control of direct hot surface ignition Ignition Source: Line Voltage (120 VAC) Hot Surface Element (Norton
systems used on gas fired furnaces, boilers, and other heating Model 201 or 270)
appliances. Ignition System Type: Direct Hot Surface Ignition
Dimensions, Approximate: 5 1/4 in. high x 4 1/16 in. wide x 1 15/16 in. Maximum Valve Load @ 24 Vac (Amps): 2A
long (133 mm high x 103 mm wide x 49 mm deep) Typical Gas Control: VR8205, VR8305
Type of Gas: Natural or LP Typical Ignition Hardware: Norton 201, Norton 271, Q354
Electrical Ratings: 24 Vac Maximum Ambient Temperature: -40 F to +175 F (-40 C to +79 C)
Frequency: 60 Hz

Hydronic Controls
Approvals:
Flame Failure Response Time (sec): 1.5 sec. Canadian Standards Association: Design Certified
Ignition Sequence: The number of trials for ignition and trial time is
determined by the selection tab. If a selection tab is not installed, the
module will operate at four seconds trial time and one ignition trial.

Ignition Trials To
Product Number Flame Sense Ignition Trial Time (sec) Between Trial Time (sec) Lockout PrePurge
• S8910U1000 Single Rod or Two Rods 4 sec. or 7 sec. (2) 96 sec.- 3 trial mode only 1 or 3 32 seconds
* TRADELINE models • SUPER TRADELINE models

Controls
Water
Y8610U Universal Retrofit Intermittent Pilot Gas Burner Ignition
Systems
Complete kits converting conventional standing pilot system to
intermittent pilot system. For use with 24 Vac gas-fired

Building Automation
atmospheric furnaces, boiler and heating appliances.
• Y8610U kits are for use with natural or LP gas: provides 100 percent
pilot gas shutoff if pilot fails to light; after 6-minute delay, trial for
ignition is repeated.
• Ignition trail/delay sequence is repeated until the appliance lights or
call for heat is removed.

Components
Application: Provide electronic control of intermittent pilot ignition Ignition Sequence: Continuous retry, after trial for ignition, pilot gas

Commercial
systems used on gas fired furnaces, boilers, and other heating shuts off for 5 minutes, then another trial for pilot ignition takes place
appliances. Ignition Source: Internal high voltage spark generator
Dimensions, Approximate: 3 15/16 in. high x 5 7/16 in. wide x 2 5/8 in. Ignition System Type: Intermittent Pilot
deep (100 mm high x 138 mm wide x 67 mm deep) Maximum Valve Load @ 24 Vac (Amps): 1A Pilot, 2A Main @ 24Vac
Type of Gas: Natural or LP Typical Gas Control: VR8204, VR8304
Electrical Ratings: 24 Vac Typical Ignition Hardware: Q345, Q3451
Frequency: 60 Hz Maximum Ambient Temperature: -40 F to +165 F (-40 C to +74 C)
Pneumatic Controls

Flame Failure Response Time (sec): 2.0 sec

Ignition Trial Time Ignition Trials To


Product Number Flame Sense (sec) Lockout PrePurge Includes
Y8610U4001 Single Rod or Two Rods 15 or 90 seconds continuous retry 0 or 30 seconds VR8204A2142 valve (1/2 x 1/2;
3.5 in. WC setting; 150 kBtu/hr at 1 in.
p.d.)
Y8610U6006 Single Rod or Two Rods 15 or 90 seconds continuous retry 0 or 30 seconds VR8304M3558 (1/2 x 3/4;
Industrial Combustion

3.5 in. setting; 270kBtu/hr at 1 in. p.d.)


Controls

70-6910 139
Ignition Pilot Modules Selection Guide
Ignition Pilot Modules Selection Guide
Applications Timings
Ignition
Ignition Trials To
Universal Sequence Lockout Flame Failure
Service Part Ignition System Flame Sensor (Note 1) (Note 1) Ignition Trial Time Between Trial Time Pre-Purge Response Time
Line Volt Hot 1 or 3 Field 4 sec. or 7 sec. Field 96 sec., 3 Trial Mode
S8910U1000 1 or 2 Rods P 32 sec. 1.5 sec
Surface Ignition Selectable Selectable Only
5 Minute Delay After 0 sec. or 30
S8610U3009 Intermittent Pilot 1 or 2 Rods C C 15 sec. or 90 sec. Failed Trial for sec. Field 2.0 sec. max.
Field Selectable
Ignition Selectable
5 Minute Delay After
15 sec. or 90 sec.
Y8610U6006 Intermittent Pilot Single Rod C C Failed Trial for 0 sec. 2.0 sec. max.
Field Selectable
Ignition

Features and Functions Cross-Reference


Typical
Universal Type of Ignition Ignition Johnson
Service Part Gas Source Hardware Includes Honeywell White-Rodgers Robertshaw Controls
S89C1004, S89C1007,
S89C1012, S89C1046, HS780-17NL 104A,
S89C1087, S89C1103, 306A, 308A; HS780-
Norton 201,
Norton 271, S89D1002, S89G1005, 17NR 104A, 306A,
50E47 1-79, 101-179,
Switched Hot Surface S89F1011, S89G1013, 308A; HS780-34NL
S8910U1000 Nat or LP — S89G1021, S89G1029, 201-279, 301-379;
108A, 304A, 306A, —
Line Voltage Elements, 5047F1-79, 101-179,
Q354 Flame S89G1047, S89H1003, 308A, 312A; HS780-
201-279, 301-379
Rod S89H1011, S89H1029, 34NR 104A, 306A,
S89J1008, S890D1006, 308A, 312A; HS780-
S890G1003, S890G1037, 34PL 308A
S89H1002, S890H1010
710-713, 710-715, 735-
S86 Series, S90 Series, 737, 780-002, 780-003, CSA42, 43,
Internal 50D49-350, 50D49- 780-701, 780-715, 780- 44, 45, 46,
S8610U3009 Nat or LP Internal Q345, Q3451, Damper S8600 Series, S8610 Series,
360, 50D49-361, 735,780-736, 780-737, 48, 49; G60,
Q3452 S8620 Series, S8660 Series,
Connector 50D50-843, 50D-401 780-845, SP710, G65, G67,
S8670 Series, S8680J1004
SP715, SP720, SP730, G770 Series
SP735, SP750 Series
Adapter for
Y8610U6006 Nat or LP Internal Pilot Burner — Y8610U3003 — — —
Included

Notes:

1. Ignition Sequence

C = Continuous retry - After trial for ignition, pilot gas shuts off for 5 minutes, then another trial for pilot ignition takes place.

P = The number of trials for ignition and trial time is determined by the selection tab. If a selection tab is not installed, the module will operate at four seconds trial time and
one ignition trial.

For a complete cross-reference, visit www.customer.honeywell.com

140 customer.honeywell.com 70-6910


Gas Ignition Module Accessories
Gas Ignition Module Accessories

Controls
Home
Product Number Description
392125-1 25 in. ignition cable assembly with a right angle boot on the igniter end and a
straight boot on the module end. For use with the S86/S87 family.
392125-2 36 in. ignition cable assembly with a right angle boot on the igniter end and a

Indoor Air Quality


straight boot on the module end. For use with the S86/S87 family.
392125-5 18 in. ignition cable assembly with a right angle boot on the igniter end and a
straight boot on the module end. For use with the S86/S87 family.
393044 Y86 Wiring Harness Assembly

Combustion Controls
Residential
394800-30 30 in. Ignition Cable with Right Angle Boot for use with S8600 family

Hydronic Controls
394801-30 30 in. Ignition Cable Assembly with straight boot for use with S8600 family

394803-2 36 in. High Temperature right angle boot and cable Assembly for S8600 family

Controls
Water
4074EPM Male Rajah to 1/4 in. Female Quick Connect adapter for use with S8600 family

Building Automation
Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 141
Igniter Bracket Replacement Cross Reference
Q3200U Igniter Bracket Replacement Cross Referencea
Manufacturer OEM Part Number Q3200U Bracketb Manufacturer OEM Part Number Q3200U Bracketb
Roberts Gordon 90434300 B
American Road Equip. 201W A
90436600 A
Arco Air 1096048
D Robert-shaw 41-402 A
1380680
41-403
Armstrong Air 38322B001 A B
41-404
Carrier/Bryant/Payne LH33ZS001
41-405 A
LH33ZS001A
41-407 B
LH33ZS002
41-408 A
LH33ZS002A B or Ec
41-409 B
LH33ZS003
41-410 A
LH33ZS003A
41-412 D
LH33ZS004
41-418 C
Claire Bros. C-238
A Snyder General 1380654
C242
1380672 B
Coleman 1474-051
A 1380680
1474-052
Superior Fireplace 94851 A
Comfort Maker 1096048 D
Tempstar 1096048 D
Detroit Radiant 201D A
Trane 340039P01 A
DMO Industries 20834 A
B138196P01 B
Dornback Furnace 271W A
B144676P01 A
Ducane 20015201 B
B144676P02 B
Enero Tech 10399 A
B340039P01
Evcon 1474-051 A
A IGN23
1474-052
IGN26
Evcon Coleman 025-32625-000 B B
IGN30
Goodman B1401009 D
IGN34 A
B1401018 C
Viessman 9302-094 A
B1401018S D
Wayne Home Equip. 62821-001
HB Smith 50018 A A
62821-002
Heil 1096048 D
Weil McLain 511-330-139
Hupp Industries 09050 A
511-330-190 B
Intercity 1009604
D 511-330-193
1096048
White LB 120-07549 A
Majestic 75-92-104
A White-Rodgers 767A-301 A
75-92-105
767A-303 F
Metzger 201N
A 767A-306
201W
767A-311 A
Modine 5H76032A C
767A-350
Mor-Flo 3200618 A
767A-353 F
511-330-193 B
767A-354 A
Nordyne 105141000
767A-357 F
632-0770 A
767A-361
632-0880
767A-364 A
Norton/St Gobain 201
B 767A-366
271
767A-370 B
201D
767A-371
201K A
767A-372
201L
767A-373 D
201N A
767A-376 B
201R
767A-377 A
201W
767A-382 B
271N
Williamson 9050 A
271NM D
York 025-27766-000 A
271P
A 025-27774-000 A
271W
025-29043-000 A
Raypak 600915 B
025-29050-000 A
Rheem 62-22441-01 A
a Table data is correct to the best of Honeywell’s knowledge as of this
a Table data is correct to the best of Honeywell’s knowledge as of this
publication’s date. However, some appliances may have igniter appli-
publication’s date. However, some appliances may have igniter appli-
cations that are beyond the capabilities of this kit.
cations that are beyond the capabilities of this kit.
b For igniters that require bracket A, use the template to determine the
b For igniters that require bracket A, use the template to determine the
tab to be removed.
tab to be removed.
c For Carrier sealed combustion furnaces, you must use bracket E and
c For Carrier sealed combustion furnaces, you must use bracket E and
retain the existing orange gasket for use with bracket E.
retain the existing orange gasket for use with bracket E.

142 customer.honeywell.com 70-6910


Igniters and Sensors
Q3200 Glowfly™ Universal Hot Surface Igniter Kit

Controls
Home
The Q3200U Universal Hot Surface Igniter Kit is designed to
provide a robust field service replacement igniter in gas fired
appliances with Norton/St Gobain 120 VAC silicon carbide hot
surface igniters. The Q3200U uses a 120 volt silicon nitride igniter
design with long life and high resistance to damage or burn out in
the appliance.

Indoor Air Quality


The kit includes the specially designed silicon nitride igniter and
six different bracket configurations to adapt the igniter to the
specific appliance application along with accessory parts to allow
mounting and wiring the igniter. Clear instructions and application
templates are provided to simplify selection of the proper bracket
and ease installation of the replacement.

Mounting Bracket: Multiple brackets to adapt as field replacement of


Norton/St. Gobain silicon carbide igniters

Combustion Controls
Product Number Description

Residential
Q3200U1004 Glowfly™ Universal Hot Surface Igniter. Single Kit
Q3200U2002 Glowfly™ Universal Hot Surface Igniter. Service Pack of 6 kits

Q347 Spark Igniter


Produces spark for direct ignition of main burner.

Hydronic Controls
• Includes inner Kanthal electrode with ceramic insulator, bracket and
Kanthal ground strap.
• Use with S87C, D, K; S89E,F and Q354A.

Ignitor, Sensor, Combination: Ignitor Only


Mounting Bracket: Bracket Style D

Controls
Water
Length Mounting
Product Number (inch) (mm) (inch) (mm) Rod Angle Description
Q347A1004 2 1/32 in. 52 mm One 3/16 in. slot, three 3/16 in. One 5 mm slot, three 5 mm standard Spark Ignitor Sensor with
untapped screw holes. untapped screw holes. orientation style D mounting bracket

Building Automation
Q347A1012 2 1/32 in. 52 mm One 3/16 in. slot, three 3/16 in. One 5 mm slot, three 5 mm 90½ angle Spark Ignitor Sensor with
untapped screw holes. untapped screw holes. style D mounting bracket

Q354 Flame Rectification Sensor


Detects the presence of main burner flame.
• Includes Kanthal rod supported by ceramic insulator and mounting
bracket.
• Use with S825, S87C,D,K or S89E,F.

Components
Commercial
Ignitor, Sensor, Combination: Sensor Only
Mounting Bracket: One 3/16 in. slot, three 3/16 in. untapped screw
holes.

Length Mounting
Pneumatic Controls

Product Number (inch) (mm) (inch) (mm) Rod Angle Description


Q354A1018 6 3/8 in. 162 mm One 3/16 in. slot, three 3/16 in. One 5 mm slot, three 5 mm straight Flame Sensor with 6.37 in. rod
untapped screw holes. untapped screw holes. height used with S825 or S87
Industrial Combustion
Controls

70-6910 143
Pressure Switches
Airflow Differential Pressure Switch
Airflow Differential Pressure Switches are used to sense positive,
negative, or differential air pressure in HVAC systems. They
provide high or low limit with alarm or high limit shutdown with
manual reset.
• Models available with compression or barb fittings.
• SPDT contacts on automatic reset models SPST n.c. contacts on
manual reset models.
• Electrical switch enclosed in metal box with cover.
• Reliable pneumatic operation. UL and CSA Listed, FM approved.
• Adjustable setpoint.

Dimensions, Approximate: 5.0 in. Diameter (127 mm Diameter)


Electrical Ratings: 278 Va @ 24Vac; 300Va @ 120 to 277Vac
Electrical Connections: #6-32 Screw terminal with cup washers
Ambient Temperature Range: -40 F to +190 F (-40 C to +88 C)
Approvals:
Canadian Standards Association: CSA file No. LR45785
Factory Mutual: Listed: J.I. 1H3A6.AF
Underwriters Laboratories, Inc. Listed: MP2168

Maximum
Connection Electrical Operating
Product Number Type Switch Pilot Duty Ratings Pressure Setpoint Additional Features
AP5027-30 1/4 in. SPDT Gold Flash Contacts; 1/2 psi .05"±.02 in. wc to Switching Differential: .02"±.01 in. wc @
Compression 10 Milliamps @ 5Vdc; 12.0 in. wc PR minimum set point to approximately
15 Amps resistive to 277Vac .80 in. wc @ maximum set point
AP5208-30 1/4 in. Barbed SPDT Gold Flash Contacts; 1/2 psi .05"±.02 in. wc to Switching Differential: .02"±.01 in. wc @
10 Milliamps @ 5Vdc; 12.0 in. wc PR minimum set point to approximately
15 Amps resistive to 277Vac .80 in. wc @ maximum set point
AP5210-30 1/4 in. SP N.C. — 1/2 psi .30"±.20 in. wc to Manual Reset
Compression 12.0 in. wc PR

144 customer.honeywell.com 70-6910


Electronic Fan Timers
ST9103 Electronic Fan Timers

Controls
Home
ST9103A integrates control of burner and circulating fan
operations in an oil furnace.
• Central appliance wiring point simplifies appliance assembly and
service.
• Fixed or field-adjustable heat fan on delay; field adjustable heat fan
off delay.

Indoor Air Quality


Application: A single circuit board providing combustion air blower
control, two speed circulating air blower control, oil primary control,
limit circuit inputs, thermostat wiring terminations, & a central
appliance wiring point for an oil fixed furnace.
Electrical Ratings: 18 to 30 Vac
Frequency: 60 Hz; 50 Hz
Approvals:
Canadian Standards Association: Certified: File No. LR95329-17

Combustion Controls
Underwriters Laboratories, Inc. Listed: Report MP466

Residential
Ambient Temperature Range
Heat Fan Cool Fan Cool Fan
Product Number On Delay Heat Fan Off Delay On Delay Off Delay (F) (C) Replaces
ST9103A1002 fixed, 45 sec adj. 60, 90, 120, 150 sec (set at 150 sec) fixed 0 sec fixed 0 sec -40 F to +150 F -40 C to +66 C ST9103A1002

ST9120 Electronic Fan Timers

Hydronic Controls
The ST9120U Universal Electronic Fan Timers integrate control of
all combustion blower and circulating fan operations in a gas
warm air appliance. This control is the central wiring point for most
of the electrical components in the furnace. The basic purposes of
the ST9120U are to monitor the thermostat for heat, cool and fan
demands, run the induced draft blower motor and run a circulating
fan (up to two speeds) as required. The ST9120U also monitors
limit switch strings and energizes separate ignition control
systems through pressure switches. The ST9120U can replace any
ST9101, ST9120, ST9141 or ST9160 listed in Table 3 below. The
ST9120U features a field-adjustable heat fan-on delay, a field-

Controls
Water
adjustable heat fan-off delay, a field adjustable cool fan-on delay
and a field-adjustable cool fan-off delay.
Electronic air cleaner (EAC) and humidifier (HUM) convenience
terminal connections and continuous low speed indoor air
circulation are provided.

Application: Integrates control of combustion blower and circulating

Building Automation
fan operations for a gas warm air appliance
Electrical Ratings: 18 to 30 Vac
Frequency: 60 Hz; 50 Hz
Approvals:
Canadian Standards Association: Certified: File No. LR95329-17
Underwriters Laboratories, Inc. Listed: Report MP466

Ambient Temperature
Range
Heat Fan On Cool Fan On Cool Fan Off

Components
Product Number Delay Heat Fan Off Delay Delay Delay (F) (C) Replaces

Commercial
* ST9120U1011 adj. 30, 60 sec adj. 60, 120, 150, 180 adj. 4, 30 sec adj. 30, 60 sec -40 F to -40 C to all ST9101's, all ST9120's, all
(set at 30 sec) sec (set at 120 sec) (set at 4 sec) (set at 30 sec) +175 F +79 C ST9141's, and all ST9160's
* TRADELINE models • SUPER TRADELINE models
Pneumatic Controls
Industrial Combustion
Controls

70-6910 145
Contactors
PowerPro Definite Purpose Contactors

The Tougher Contactors


We're tougher than ever. Honeywell PowerPro, a line of definite • Honeywell PowerPro Contactors Meet ARI Standard 780—
purpose contactors, outfeatures, outperforms and is destined to Meeting the ARI Standard 780 means that the contactors stand up to
soon outsell the competition. tests that simulate harsh, real-world conditions—500,000 cycle
Once you compare the features of Honeywell PowerPro definite mechanical life test, 200,000 cycle endurance life test and 10,000
cycle recycle life test.
purpose contactors against what you're using now, we predict
you'll soon standardize on PowerPro for all your applications. • Contactors are shorter and sweeter than the competition—Their
Especially in ‘high stakes’ situations where you can't afford to small size makes them ideal for replacement inside today's compact
gamble on anything less. equipment.
• Advanced class H insulated contactor coil design protects
Honeywell PowerPro definite purpose contactors will surprise you
against high heat conditions—Class H contactor coils are
in more ways than one. Once you try them you'll be amazed at how standard on 5000 Series 3-pole, 25A through 60A models.
these compact contactors easily fit in tight spaces while leaving
maneuvering room for hands and tools; how easily contactor • Convenient button for easy testing—Use it to safely check for
accessories snap on or off; how you view the operation of the con- proper electrical functioning of the contactor.
tactor with the user-friendly button; plus many other installer-
friendly features

DP Contactors Order Number Guide


It's easy to select the order number that you need for your application. Depending on your application, determine the number of poles, amp rating,
coil voltage, and whether you need an economy or deluxe model. Then, simply follow this Order Number Guide:

Product Identifier Pole Number of Series


Definite Purpose Identifier Poles Indentifier Type
Contactor 0 1 pole without shunt 1000-4999 Economy
1 1 pole with shunt 5000 and up Deluxe PowerPro™
2 2 poles ARI-780 rated
3 3 poles
4 4 poles

DP 3 040 B 5001
Amperage Amperage Coll Coil
Identifier Rating Identifier Voltage
020 20 Amps A 24 Vac
025 25 Amps B 120 Vac
030 30 Amps C 208/240 Vac
040 40 Amps D 277 Vac
050 50 Amps E 480 Vac
060 60 Amps F 600 Vac
075 75 Amps
090 90 Amps
120 120 Amps M14500

NOTE: Super Tradeline Contactors contain extra mounting hardware.

146 customer.honeywell.com 70-6910


Contactors
Deluxe Honeywell PowerPro DP-Series Definite Purpose Contactors

Controls
Home
- 1 Pole
These electromagnetically-operated Definite Purpose Contactors
provide switching for starting induction motors.
• Meets ARI-780 Standard at started ratings (500,000 cycle
mechanical life, 200,000 cycle electrical life and 10,000 cycle recycle
life); the most demanding ARI requirement.

Indoor Air Quality


• Silver cadmium oxide contacts provide long life under demanding
duty cycles.
• Low profile design allows for more wiring room.
• Multiple mounting holes and slots for convenient, interchangeable
mounting with most competitive devices.

Application: PowerPro Definite Purpose Contactor


Temperature Range: -4 F to +149 F (-20 C to +65 C)

Combustion Controls
Approvals:
Canadian Standards Association: Certified: File No. LR6535

Residential
Underwriters Laboratories, Inc. Component Recognized: File No.
14480, Guide No. NLDX2

Contact Electrical Ratings Dimensions, Approximate


Coil Contact Electrical
Ratings Connections Connections AFL @ 277, 480, Resistive @ 277,
Product Number Poles Voltage (coil) (main) 600 Vac 480, 600 Vac (inch) (mm)
* DP1025A5005 1 with shunt 24 Vac 1/4 in. quick- #10-32 25 A @ 240/277 Vac 30 A @ 240/277 Vac, 2.2 in. high x 56 mm high x

Hydronic Controls
connects combination 480 Vac, 600 Vac 2.5 in. wide x 59 mm wide x
head screws 3.31 in. deep 84 mm deep
* DP1030A5013 1 with shunt 24 Vac 1/4 in. quick- #10-32 30 A @ 240/277 Vac 48 A @ 240/277 Vac 2.2 in. high x 56 mm high x
connects combination 2.5 in. wide x 59 mm wide x
head screws 3.31 in. deep 84 mm deep
* DP1040A5004 1 with shunt 24 Vac 1/4 in. quick- #10-32 40 A @ 240/277 Vac 55 A @ 240/277 Vac 2.36 in. high x 60 mm high x
connects combination 3.2 in. wide x 81 mm wide x
head screws 2.0 in. deep 51 mm deep
* TRADELINE models • SUPER TRADELINE models

Controls
Water
Building Automation
Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 147
Contactors
Deluxe Honeywell PowerPro DP-Series Definite Purpose Contactors
- 2 Pole
These electromagnetically-operated Definite Purpose Contactors
provide switching for starting induction motors.
• Meets ARI-780 Standard at started ratings (500,000 cycle
mechanical life, 200,000 cycle electrical life and 10,000 cycle recycle
life); the most demanding ARI requirement.
• Silver cadmium oxide contacts provide long life under demanding
duty cycles.
• Low profile design allows for more wiring room.
• Multiple mounting holes and slots for convenient, interchangeable
mounting with most competitive devices.

Application: PowerPro Definite Purpose Contactor


Temperature Range: -4 F to +149 F (-20 C to +65 C)
Approvals:
Canadian Standards Association: Certified: File No. LR6535
Underwriters Laboratories, Inc. Component Recognized: File No.
14480, Guide No. NLDX2

Contact Electrical Ratings Dimensions, Approximate


Coil Contact
Ratings Connections Electrical AFL @ 277, 480, Resistive @ 277,
Product Number Poles Voltage (coil) Connections (main) 600 Vac 480, 600 Vac (inch) (mm)
* DP2020A5021 2 24 Vac 1/4 in. quick- #10-32 combination 20 A @ 240, 277, 30 A @ 240/277 Vac, 2.2 in. high x 56 mm high x
connects head screws 480, 600 Vac 480 Vac, 600 Vac 2.5 in. wide x 59 mm wide x
3.31 in. deep 84 mm deep
* DP2020B5038 2 120 Vac 1/4 in. quick- #10-32 combination 20 A @ 240, 277, 30 A @ 240/277 Vac, 2.2 in. high x 56 mm high x
connects head screws 480, 600 Vac 480 Vac, 600 Vac 2.5 in. wide x 59 mm wide x
3.31 in. deep 84 mm deep
* DP2030A5004 2 24 Vac 1/4 in. quick- #10-32 combination 30 A @ 240/277 Vac 48 A @ 240/277 Vac 3.25 in. high x 83 mm high x
connects head screws and sems 3.63 in. wide x 67 mm wide x
screws 3.8 in. deep 95 mm deep
* DP2030A5012 2 24 Vac 1/4 in. quick- #10-32 combination 30 A @ 240/277 Vac 48 A @ 240/277 Vac 3.25 in. high x 83 mm high x
connects head screws and sems 3.63 in. wide x 67 mm wide x
screws 3.8 in. deep 95 mm deep
* DP2030B5003 2 120 Vac 1/4 in. quick- #10-32 combination 30 A @ 240/277 Vac 48 A @ 240/277 Vac, 2.2 in. high x 56 mm high x
connects head screws and sems 480 Vac, 600 Vac 2.5 in. wide x 59 mm wide x
screws 3.31 in. deep 84 mm deep
* DP2030B5011 2 120 Vac 1/4 in. quick- #10-32 combination 30 A @ 240/277 Vac 48 A @ 240/277 Vac, 2.2 in. high x 56 mm high x
connects head screws and sems 480 Vac, 600 Vac 2.5 in. wide x 59 mm wide x
screws 3.31 in. deep 84 mm deep
* DP2030C5002 2 208 Vac/ 1/4 in. quick- sems screws 30 A @ 240/277 Vac 48 A @ 240/277 Vac, 2.2 in. high x 56 mm high x
240 Vac connects 480 Vac, 600 Vac 2.5 in. wide x 59 mm wide x
3.31 in. deep 84 mm deep
* DP2030C5010 2 208 Vac/ 1/4 in. quick- #10-32 combination 30 A @ 240/277 Vac 48 A @ 240/277 Vac, 2.2 in. high x 56 mm high x
240 Vac connects head screws and sems 480 Vac, 600 Vac 2.5 in. wide x 59 mm wide x
screws 3.31 in. deep 84 mm deep
* DP2030D5001 2 277 Vac 1/4 in. quick- sems screws 30 A @ 240/277 Vac 48 A @ 240/277 Vac, 2.2 in. high x 56 mm high x
connects 480 Vac, 600 Vac 2.5 in. wide x 59 mm wide x
3.31 in. deep 84 mm deep
* DP2040A5003 2 24 Vac 1/4 in. quick- lug connectors 40 A @ 240/277 Vac 50 A @ 240/277 Vac 2.36 in. high x 60 mm high x
connects 3.2 in. wide x 81 mm wide x
2.0 in. deep 51 mm deep
* DP2040B5002 2 120 Vac 1/4 in. quick- lug connectors 40 A @ 240/277 Vac 50 A @ 240/277 Vac 2.36 in. high x 60 mm high x
connects 3.2 in. wide x 81 mm wide x
2.0 in. deep 51 mm deep
* DP2040C5001 2 208 Vac/ 1/4 in. quick- #10-32 combination 40 A @ 240/277 Vac 50 A @ 240/277 Vac 2.36 in. high x 60 mm high x
240 Vac connects head screws 3.2 in. wide x 81 mm wide x
2.0 in. deep 51 mm deep
* TRADELINE models • SUPER TRADELINE models

148 customer.honeywell.com 70-6910


Contactors
Deluxe Honeywell PowerPro DP-Series Definite Purpose Contactors

Controls
Home
- 3 Pole
These three pole definite purpose electromagnetically operated
contactors provide switching for starting of induction motors.
• Shrouded coils on 3 pole (25A to 60A) models protect the coil from
harsh environment factors.
• Moisture proof epoxy is used to encapsulate the 3 pole 75A through

Indoor Air Quality


120A coils.
• Multiple mounting holes and slots for convenient, interchangeable
mounting with most competitive devices.
• Traditional design meets many needs.
• Full array of replacement coils, contact sets and accessories
available.

Application: PowerPro Definite Purpose Contactor


Temperature Range: -4 F to +149 F (-20 C to +65 C)

Combustion Controls
Approvals:

Residential
Canadian Standards Association: Certified: File No. LR6535
Underwriters Laboratories, Inc. Component Recognized: File No.
14480, Guide No. NLDX2

Contact Electrical Ratings Dimensions, Approximate


Coil Contact Electrical
Ratings Connections Connections AFL @ 277, 480, Resistive @ 277,
Product Number Poles Voltage (coil) (main) 600 Vac 480, 600 Vac (inch) (mm)

Hydronic Controls
* DP3030A5003 3 24 Vac 1/4 in. quick- #10-32 30 A @ 240/277 Vac, 40 A @ 240/277 Vac, 3.1 in. high x 79 mm high x
connects and combination 480 Vac, 600 Vac 480 Vac, 600 Vac 3.62 in. wide x 92 mm wide x
#6 screws head screws 2.4 in. deep 61 mm deep
* DP3030B5002 3 120 Vac 1/4 in. quick- #10-32 30 A @ 240/277 Vac, 40 A @ 240/277 Vac, 3.1 in. high x 79 mm high x
connects and combination 480 Vac, 600 Vac 480 Vac, 600 Vac 3.62 in. wide x 92 mm wide x
#6 screws head screws 2.4 in. deep 61 mm deep
* DP3030C5001 3 208 Vac/ 1/4 in. quick- #10-32 30 A @ 240/277 Vac, 40 A @ 240/277 Vac, 3.1 in. high x 79 mm high x
240 Vac connects and combination 480 Vac, 600 Vac 480 Vac, 600 Vac 3.62 in. wide x 92 mm wide x
#6 screws head screws 2.4 in. deep 61 mm deep

Controls
* DP3040A5002 3 24 Vac 1/4 in. quick- lug connectors 40 A @ 240/277 Vac, 50 A @ 240/277 Vac, 3.1 in. high x 79 mm high x

Water
connects and 480 Vac, 600 Vac 480 Vac, 600 Vac 3.62 in. wide x 92 mm wide x
#6 screws 2.4 in. deep 61 mm deep
* DP3040B5001 3 120 Vac 1/4 in. quick- lug connectors 40 A @ 240/277 Vac, 50 A @ 240/277 Vac, 3.1 in. high x 79 mm high x
connects and 480 Vac, 600 Vac 480 Vac, 600 Vac 3.62 in. wide x 92 mm wide x
#6 screws 2.4 in. deep 61 mm deep
* DP3040C5000 3 208 Vac/ 1/4 in. quick- lug connectors 30 A @ 240/277 Vac, 40 A @ 240/277 Vac, 3.1 in. high x 79 mm high x

Building Automation
240 Vac connects and 480 Vac, 600 Vac 480 Vac, 600 Vac 3.62 in. wide x 92 mm wide x
#6 screws 2.4 in. deep 61 mm deep
* DP3050A5001 3 24 Vac 1/4 in. quick- lug connectors 50 A @ 240/277 Vac, 63 A @ 240/277 Vac, 3.1 in. high x 79 mm high x
connects and 480 Vac, 600 Vac 480 Vac, 600 Vac 3.62 in. wide x 92 mm wide x
#6 screws 2.4 in. deep 61 mm deep
* DP3050B5000 3 120 Vac 1/4 in. quick- lug connectors 50 A @ 240/277 Vac, 63 A @ 240/277 Vac, 3.1 in. high x 79 mm high x
connects and 480 Vac, 600 Vac 480 Vac, 600 Vac 3.62 in. wide x 92 mm wide x
#6 screws 2.4 in. deep 61 mm deep
* DP3050C5009 3 208 Vac/ 1/4 in. quick- lug connectors 50 A @ 240/277 Vac, 63 A @ 240/277 Vac, 3.1 in. high x 79 mm high x
240 Vac connects and 480 Vac, 600 Vac 480 Vac, 600 Vac 3.62 in. wide x 92 mm wide x

Components
Commercial
#6 screws 2.4 in. deep 61 mm deep
* DP3060A5000 3 24 Vac 1/4 in. quick- lug connectors 60 A @ 240/277 Vac, 75 A @ 277 Vac, 480 3.1 in. high x 79 mm high x
connects and 480 Vac, 600 Vac Vac, 600 Vac 3.62 in. wide x 92 mm wide x
#6 screws 2.4 in. deep 61 mm deep
* DP3060B5009 3 120 Vac 1/4 in. quick- lug connectors 60 A @ 240/277 Vac, 75 A @ 277 Vac, 480 3.1 in. high x 79 mm high x
connects and 480 Vac, 600 Vac Vac, 600 Vac 3.62 in. wide x 92 mm wide x
#6 screws 2.4 in. deep 61 mm deep
Pneumatic Controls

* DP3060C5008 3 208 Vac/ 1/4 in. quick- lug connectors 60 A @ 240/277 Vac, 75 A @ 277 Vac, 480 3.1 in. high x 79 mm high x
240 Vac connects and 480 Vac, 600 Vac Vac, 600 Vac 3.62 in. wide x 92 mm wide x
#6 screws 2.4 in. deep 61 mm deep
* DP3075A5016 3 24 Vac 1/4 in. quick- lug connectors 75 A @ 240/277 Vac, 95 A @ 240/277 Vac, 4.4 in. high x 5 112 mm high x
connects and 480 Vac, 600 Vac 480 Vac, 600 Vac in. wide x 3.7 127 mm wide x
#6 screws in. deep 94 mm deep
* DP3075B5015 3 120 Vac 1/4 in. quick- lug connectors 75 A @ 240/277 Vac, 95 A @ 240/277 Vac, 4.4 in. high x 5 112 mm high x
connects and 480 Vac, 600 Vac 480 Vac, 600 Vac in. wide x 3.7 127 mm wide x
#6 screws in. deep 94 mm deep
Industrial Combustion

* TRADELINE models • SUPER TRADELINE models


Controls

70-6910 149
Contactors
Contact Electrical Ratings Dimensions, Approximate
Coil Contact Electrical
Ratings Connections Connections AFL @ 277, 480, Resistive @ 277,
Product Number Poles Voltage (coil) (main) 600 Vac 480, 600 Vac (inch) (mm)
* DP3075C5014 3 208 Vac/ 1/4 in. quick- lug connectors 75 A @ 240/277 Vac, 95 A @ 240/277 Vac, 4.4 in. high x 5 112 mm high x
240 Vac connects and 480 Vac, 600 Vac 480 Vac, 600 Vac in. wide x 3.7 127 mm wide x
#6 screws in. deep 94 mm deep
* DP3090B5006 3 120 Vac 1/4 in. quick- lug connectors 90 A @ 240/277 Vac, 120 A @ 240/277 4.4 in. high x 5 112 mm high x
connects and 480 Vac, 600 Vac Vac, 480 Vac, 600 Vac in. wide x 3.7 127 mm wide x
#6 screws in. deep 94 mm deep
* DP3090C5005 3 208 Vac/ 1/4 in. quick- lug connectors 90 A @ 240/277 Vac, 120 A @ 240/277 4.4 in. high x 5 112 mm high x
240 Vac connects and 480 Vac, 600 Vac Vac, 480 Vac, 600 Vac in. wide x 3.7 127 mm wide x
#6 screws in. deep 94 mm deep
* TRADELINE models • SUPER TRADELINE models

Deluxe Honeywell PowerPro DP-Series Definite Purpose Contactors


- 4 Pole
Definite purpose four (40A) pole contactors provide switching for
across-the-line starting of induction motors.
• Shrouded coils on 3 pole (25A to 60A) models protect the coil from
harsh environment factors.
• Moisture proof epoxy is used to encapsulate the 3 pole 75A through
120A coils.
• Multiple mounting holes and slots for convenient, interchangeable
mounting with most competitive devices.
• Traditional design meets many needs.
• Full array of replacement coils, contact sets and accessories
available.

Application: PowerPro Definite Purpose Contactor


Temperature Range: -4 F to +149 F (-20 C to +65 C)
Approvals:
Canadian Standards Association: Certified: File No. LR6535
Underwriters Laboratories, Inc. Component Recognized: File No.
14480, Guide No. NLDX2

Contact Electrical Ratings Dimensions, Approximate


Coil Contact Electrical
Ratings Connections Connections AFL @ 277, 480, Resistive @ 277,
Product Number Poles Voltage (coil) (main) 600 Vac 480, 600 Vac (inch) (mm)
DP4040A5001 4 24 Vac 1/4 in. quick- lug connectors 40 A @ 240/277 Vac, 50 A @ 240/277 Vac, 2.76 in. high x 70 mm high x
connects and 480 Vac, 600 Vac 480 Vac, 600 Vac 3.75 in. wide x 95 mm wide x
#6 screws 3.43 in. deep 97 mm deep
DP4040B5000 4 120 Vac 1/4 in. quick- lug connectors 40 A @ 240/277 Vac, 50 A @ 240/277 Vac, 2.76 in. high x 70 mm high x
connects and 480 Vac, 600 Vac 480 Vac, 600 Vac 3.75 in. wide x 95 mm wide x
#6 screws 3.43 in. deep 97 mm deep
DP4040C5009 4 120 Vac 1/4 in. quick- lug connectors 40 A @ 240/277 Vac, 50 A @ 240/277 Vac, 2.76 in. high x 70 mm high x
connects and 480 Vac, 600 Vac 480 Vac, 600 Vac 3.75 in. wide x 95 mm wide x
#6 screws 3.43 in. deep 97 mm deep

150 customer.honeywell.com 70-6910


Contactors
Economy DP-Series Definite Purpose Contactors - 1 Pole

Controls
Home
These electromagnetically-operated Definite Purpose Contactors
provide switching for starting induction motors.
• Silver cadmium oxide contacts provide long life under demanding
duty cycles.
• Low profile design allows for more wiring room.
• Multiple mounting holes and slots for convenient, interchangeable
mounting with most competitive devices.

Indoor Air Quality


Application: Economy Definite Purpose Contactor
Temperature Range: -4 F to +149 F (-20 C to +65 C)
Approvals:
Canadian Standards Association: Certified: File No. LR6535
Underwriters Laboratories, Inc. Component Recognized: File No.
14480, Guide No. NLDX2

Combustion Controls
Coil Contact Electrical Contact Electrical Ratings

Residential
Ratings Connections Connections
Product Number Poles Voltage (coil) (main) AFL @ 277, 480, 600 Vac Resistive @ 277, 480, 600 Vac
DP1030A1000 1 with shunt 24 Vac 1/4 in. quick- #10-32 combination 30 amps @ 240, 277, 480, 600 48 amps @ 240, 277, 480, 600
connects head screws Vac Vac

Economy DP-Series Definite Purpose Contactors - 2 Pole

Hydronic Controls
These electromagnetically-operated Definite Purpose Contactors
provide switching for starting induction motors.
• Silver cadmium oxide contacts provide long life under demanding
duty cycles.
• Low profile design allows for more wiring room.
• Multiple mounting holes and slots for convenient, interchangeable
mounting with most competitive devices.

Application: Economy Definite Purpose Contactor


Temperature Range: -4 F to +149 F (-20 C to +65 C)
Approvals:

Controls
Water
Canadian Standards Association: Certified: File No. LR6535
Underwriters Laboratories, Inc. Component Recognized: File No.
14480, Guide No. NLDX2

Contact Electrical Ratings Dimensions, Approximate


Coil Contact Electrical

Building Automation
Ratings Connections Connections AFL @ 277, 480, Resistive @ 277,
Product Number Poles Voltage (coil) (main) 600 Vac 480, 600 Vac (inch) (mm)
DP2030A1003 2 24 Vac double 1/4 in. #10 combination 30 A @ 240/277 Vac 48 A @ 240/277 Vac, 3.25 in. high x 83 mm high x
quick-connects head screws 480 Vac, 600 Vac 3.63 in. wide x 92 mm wide x
3.8 in. deep 97 mm deep
DP2030B1002 2 120 Vac double 1/4 in. #10 combination 30 A @ 240/277 Vac, 40 A @ 240/277 Vac, 2.2 in. high x 56 mm high x
quick-connects head screws 480 Vac, 600 Vac 480 Vac, 600 Vac 3.31 in. wide x 84 mm wide x
2.17 in. deep 55 mm deep
DP2030C1001 2 208 Vac/ double 1/4 in. #10 combination 30 A @ 240/277 Vac, 40 A @ 240/277 Vac, 2.2 in. high x 56 mm high x
240 Vac quick-connects head screws 480 Vac, 600 Vac 480 Vac, 600 Vac 2.5 in. wide x 59 mm wide x

Components
Commercial
3.31 in. deep 84 mm deep
DP2040A1002 2 24 Vac double 1/4 in. #10-32 combination 40 A @ 240/277 Vac, 55 A @ 240/277 Vac, 2.37 in. high x 60 mm high x
quick-connects head screws 480 Vac, 600 Vac 480 Vac, 600 Vac 3.3 in. wide x 84 mm wide x
2 in. deep 51 mm deep
DP2040B1001 2 120 Vac double 1/4 in. #10-32 combination 40 A @ 240/277 Vac, 55 A @ 240/277 Vac, 2.37 in. high x 60 mm high x
quick-connects head screws 480 Vac, 600 Vac 480 Vac, 600 Vac 3.3 in. wide x 84 mm wide x
2 in. deep 51 mm deep
Pneumatic Controls

DP2040C1000 2 120 Vac double 1/4 in. #10-32 combination 40 A @ 240/277 Vac, 55 A @ 240/277 Vac, 2.37 in. high x 60 mm high x
quick-connects head screws 480 Vac, 600 Vac 480 Vac, 600 Vac 3.3 in. wide x 84 mm wide x
2 in. deep 51 mm deep
Industrial Combustion
Controls

70-6910 151
Contactors
Auxiliary Switches
Application: Auxiliary Interlock
Contact Ratings (resistive): 10.0 A
Maximum (Inrush) Current at 120V/240V/480V/600V:
60/30/15/12 Amps
Dimensions, Approximate: 2 13/16 in. x 2 1/2 in. x 7/16 in.
(77 mm x 64 mm x 11 mm)
Used With: DP3030; DP3040; DP3050; DP3060; DP3075; DP3090

Product Number Circuits Configuration Description


DP3AUX-1NC 1 Normally Open snap-on 1 N.C. Snap-on side mounted auxiliary interlock
DP3AUX-1NO 1 Normally Closed snap-on 1 N.O. Snap-on side mounted auxiliary interlock
DP3AUX-1NO-1NC 2 Normally Open/Normally Closed snap-on 1 N.O. and 1 N.C. Snap-on side mounted auxiliary interlock
DP3AUX-2NC 2 Normally Closed snap-on 2 N.C. Snap-on side mounted auxiliary interlock
DP3AUX-2NO 2 Normally Open snap-on 2 N.O. Snap-on side mounted auxiliary interlock

R8246 Electric Heat Contactor


Provide conventional on-off control of heating elements and fan in
an electric furnace.
• Designed for quiet operation. R8246A and R8229A replace over 50
Honeywell and competitive electric heat primaries, including the
Honeywell R8330 Electric Furnace Sequencer.
• Use on furnaces with a line voltage or pilot duty limit.
• Simple ON-OFF switching - readily understood and easily serviced-
Eliminates cold drafts on system startup.

Application: Electric Heat Contactor


Temperature Range: -4 F to +149 F (-20 C to +65 C)
Contact Electrical Ratings: 48 A @ 240/277 Vac 1st pole resistive
only

Dimensions, Approximate
Coil Ratings
Product Number Poles Voltage Contact Connections (coil) Electrical Connections (main) (inch) (mm)
* R8246A1038 2 24 Vac No. 10 terminal clamp screws Male 1/4 in. (6 mm) quick-connects 2 3/16 in. high x 56 mm high x
and double male 1/4 inch quick- plus terminal clamp screws 2 5/16 in. wide x 58 mm wide x
connects 3 5/16 in. deep 84 mm deep
* TRADELINE models • SUPER TRADELINE models

152 customer.honeywell.com 70-6910


Contractors Selection Guide
Contactors Selection Guide

Controls
Home
Economy Contactors
Contact

Indoor Air Quality


Contact Ratings
Ratings (AFL @ (Resistive @
240, 277, 480, Input Voltage/ Dimensions Main Coil 240/277, 480, Special
Poles 600 Vac) Coil Voltage Product Number (in.) H x W x D Connections Connections 600 Vac) Features
1 with shunt 24 Vac DP1030A1000 2.2 x 2.5 x 3.3 CHS Q 48A —
24 Vac DP2030A1003 3.25 x 3.63 x 3.8 CHS Q 48A —
30
120 Vac DP2030B1002 2.2 x 3.3 x 2.16 CHS Q 40A —

Combustion Controls
208 Vac/240 Vac DP2030C1001 2.2 x 2.5 x 3.3 CHS Q 40A —
2

Residential
24 Vac DP2040A1002 2.37 x 3.3 x 2 LC Q 50A —
40 120 Vac DP2040B1001 2.37 x 3.3 x 2 LC Q 50A —
208 Vac/240Vac DP2040C1000 2.37 x 3.3 x 2 LC Q 50A —

Hydronic Controls
PowerPro Contactors - ARI 780/790 Rated
Contact
Ratings (AFL Input Contact Ratings
@ 240, 277, Voltage/Coil Dimensions (in.) Main Coil (Resistive @ 240/ Special
Poles 480, 600 Vac) Voltage Product Number H x W x D Connections Connections 277, 480, 600 Vac) Features
25 24 Vac DP1025A5005 2.2 x 2.5 x 3.3 CHS Q 30A —
1 with shunt 30 24 Vac DP1030A5013 2.2 x 2.5 x 3.3 CHS Q 48A —
40 24 Vac DP1040A5004 2.36 x 3.2 x 2.0 LC Q 50A —

Controls
Water
24 Vac DP2020A5021 2.2 x 2.5 x 3.3 CHS Q 30A —
20
120 Vac DP2020B5038 2.2 x 2.5 x 3.3 CHS Q 30A —
24 Vac DP2030A5004 3.25 x 3.63 x 3.8 CHS Q 48A —
24 Vac DP2030A5012 3.25 x 3.63 x 3.8 CHS Q 48A Extra
Mounting

Building Automation
HDW
120 Vac DP2030B5003 2.2 x 3.3 x 2.16 CHS Q 48A —
120 Vac DP2030B5011 2.3 x 3.3 x 2.16 CHS Q 48A Extra
Mounting
30
HDW
2
208 Vac/240 DP2030C5002 2.2 x 2.5 x 3.3 CHS Q 48A —
Vac
208 Vac/240 DP2030C5010 2.2 x 2.5 x 3.3 CHS Q 48A Extra
Vac Mounting

Components
HDW

Commercial
277 Vac DP2030D5001 2.2 x 2.5 x 3.3 CHS Q 48A —
24 Vac DP2040A5003 2.36 x 3.2 x 1.96 LC Q 50A —
120 Vac DP2040B5002 2.36 x 3.2 x 1.96 LC Q 50A —
40
208 Vac/240 DP2040C5001 2.36 x 3.2 x 1.96 LC Q 50A —
Vac
Pneumatic Controls
Industrial Combustion
Controls

70-6910 153
Contractors Selection Guide

PowerPro Contactors - ARI 780/790 Rated


Contact
Ratings (AFL Input Contact Ratings
@ 240, 277, Voltage/Coil Dimensions (in.) Main Coil (Resistive @ 240/ Special
Poles 480, 600 Vac) Voltage Product Number H x W x D Connections Connections 277, 480, 600 Vac) Features
24V DP3030A5003 3.1 x 3.62 x 2.4 CHS Q,S 40A —
120v DP3030B5002 3.1 x 3.62 x 2.4 CHS Q,S 40A —
30
208 Vac/240 DP3030C5001 3.1 x 3.62 x 2.4 CHS Q,S 40A —
Vac
24Vac DP3040A5002 3.1 x 3.62 x 2.4 LC Q,S 50A —
120Vac DP3040B5001 3.1 x 3.62 x 2.4 LC Q,S 50A —
40
208 Vac/240 DP3040C5000 3.1 x 3.62 x 2.4 LC Q,S 50A —
Vac
24Vac DP3050A5001 3.1 x 3.62 x 2.4 LC Q,S 63A —
120Vac DP3050B5000 3.1 x 3.62 x 2.4 LC Q,S 63A —
50
208 Vac/240 DP3050C5009 3.1 x 3.62 x 2.4 LC Q,S 63A —
3 Vac
24Vac DP3060A5000 3.1 x 3.62 x 2.4 LC Q,S 75A —
120 Vac DP3060B5009 3.1 x 3.62 x 2.4 LC Q,S 75A —
60
208 Vac/240 DP3060C5008 3.1 x 3.62 x 2.4 LC Q,S 75A —
Vac
24Vac DP3075A5016 4.4 x 5 x 3.7 LC Q,S 95A —
120 Vac DP3075B5015 4.4 x 5 x 3.7 LC Q,S 95A —
75
208 Vac/240 DP3075C5014 4.4 x 5 x 3.7 LC Q,S 95A —
Vac
120 Vac DP3090B5006 4.4 x 5 x 3.7 LC Q,S 120A —
90 208 Vac/240 DP3090C5005 4.4 x 5 x 3.7 LC Q,S 120A —
Vac
24 Vac DP4040A5001 2.63 x 3.75 x 3.1 LC Q,S 50A —
120 Vac DP4040B5000 2.63 x 3.75 x 3.1 LC Q,S 50A —
4 40
208 Vac/240 DP4040C5009 2.63 x 3.75 x 3.1 LC Q,S 50A —
Vac

Connectors: CHS - #10-32 Combination Head Screw

LC - Lug Connector

Q - Quick Connect

S - # 6 Screw

SS - Sems Screw

TCS - Terminal Clamp Screw

Temp Rating: -4F to 149F

Approvals: UL, CSA

ARI -780: 500,000 cycle mechanical life; 200,000 cycle electrical life; 10,000 cycle recycle life

154 customer.honeywell.com 70-6910


Contractors Selection Guide

Controls
Home
Electric Heat Contactor
Contact
Contact Input Ratings

Indoor Air Quality


Ratings (AFL Voltage/ (Resistive @
@ 240, 277, Coil Dimensions Main Coil 240/277, 480,
Poles 480, 600 Vac) Voltage Product Number (in.) H x W x D Connections Connections 600 Vac) Special Features
2 30 24 Vac R8246A1038 2.2 x 2.3 x 3.3 Q,S TCS,Q 48A @ 240/ First Pole Resistive Only,
277 Vac Second Pole Resistive/
Inductive Combined. ARI
780/790 rated.

Combustion Controls
Residential
Connectors: CHS - #10-32 Combination Head Screw

LC - Lug Connector

Q - Quick Connect

S - # 6 Screw

Hydronic Controls
SS - Sems Screw

TCS - Terminal Clamp Screw

Temp Rating: -4F to 149F

Approvals: UL, CSA

ARI -780: 500,000 cycle mechanical life; 200,000 cycle electrical life; 10,000 cycle recycle life

Controls
Water
Building Automation
Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 155
Relays
Q633 Plate-Mounted Relay Receptacle
For installing R4222, R8222 and R4228, R8228 relays on junction
boxes.
• Use with appropriate relay and AT72D1683 or AT72D1691 SUPER
TRADELINE Transformer.
• Includes relay receptacle, cover and eight leadwires.

Dimensions, Approximate: 4 in. x 4 in. plate (102 x102 mm plate)


Approvals:
CE: Approved
Canadian Standards Association: Recognized
Underwriters Laboratories, Inc. UL Component Recognized

Product Number Description


* Q633A1007 Plate Mounted Relay Receptacle
* TRADELINE models • SUPER TRADELINE models

R24 Heat Sequencer


Honeywell R24 Series Heat Sequencers are solid-state positive
temperature coefficient (PTC) heaters that mount in any position.
Quick-connect terminals speed up installation. In addition to the
fact that, the R24 Series Heat Sequencers replace a wide range of
models.
• Solid-state PTC Heaters
• Quick-connect terminals
• Shock and vibration resistant
• Mounts in any position
• Contact ratings - to 25 Amps at 120 or 240 Volts, and 12.5 Amps at
480 Volts
• Full-load rating auxiliary contacts
• Standard operating ambience temperature between -40 F and 165 F
(-40 C and 73.8 C)
• UL approved, CSA/CUR approval pending

Electrical Connections (main): Solder or screw type 1/4 in. quick


connect
Approvals:
Underwriters Laboratories, Inc. UL File 237660

Input/ Number of
Control Switches/ Number of Off-Timing Delay On-Timing Delay Electrical Ratings,
Product Number Application Voltage Devices On-Timings (sec) (sec) Contacts (Resistive)
R24AA1008 Electric Heat 24V 1 1 40 - 110 sec 1 - 20 sec 25A Resistive and 14A
Inductive at 120Vac
R24AA2006 Heat Pump - 24V 1 1 65-115: Cool 1-25: Heat 25A Resistive and 14A
Air Handler Inductive at 120Vac
R24AA3004 Electric Heat 24V 1 1 1 - 30 sec 30 - 90 sec 25A Resistive and 14A
Inductive at 120Vac
R24BA1006 Electric Heat 24V 2 1 40 - 110 sec (1st and 2nd 1 - 20 sec (1st and 2nd 25A Resistive and 14A
switch) switch) Inductive at 120Vac
R24BA3002 Electric Heat 24V 2 1 1 - 30 sec (1st and 2nd 30 - 90 sec (1st and 2nd 25A Resistive and 14A
switch) switch) Inductive at 120Vac
R24CB4007 Electric Heat 24V 3 2 1 - 110 sec (1st, 2nd and 1 - 110 sec (1st, 2nd and 25A Resistive and 14A
3rd switch) 3rd switch) Inductive at 120Vac
R24DB4005 Electric Heat 24V 4 2 1 - 110 sec (1st, 2nd, 3rd 1 - 110 sec (1st, 2nd, 3rd 25A Resistive and 14A
and 4th switch) and 4th switch) Inductive at 120Vac
R24ED5007 Electric Heat 24V 5 4 1 - 160 sec (1st, 2nd, 3rd 1 - 160 sec (1st, 2nd, 3rd 25A Resistive and 14A
and 4th switch) and 4th switch) Inductive at 120Vac

156 customer.honeywell.com 70-6910


Relays
R4222; R8222 General Purpose and

Controls
Home
R8228 Heavy Duty Switching Relays
Provide heavy duty switching for refrigeration and air conditioning
equipment, appliances, vending machines and similar
applications.
• Molded terminal numbers and circuit diagram on top of relay provide
easy identification for wiring and checking system operation.

Indoor Air Quality


• Untaped coil assures cooler operation.
• Laminated magnet construction for higher efficiency.
• Base designed for easy replacement of competitive relays.
• Double quick-connect coil terminals.
• Plug compatible with Steveco 90-340 and Mars 90340.

Dimensions, Approximate: 1 7/8 in. high x 2 5/32 in. wide x 2 3/8 in.
deep (48 mm high x 55 mm wide x 60 mm deep.)
Electrical Connections (main): 1/4 in. quick-connect terminals

Combustion Controls
Temperature Rating: -20 F to +150 F (-29 C to +66 C)

Residential
Approvals:
CE: Approved
Canadian Standards Association: Approved
Underwriters Laboratories, Inc. UL Component Recognized
Accessories:
129384A Case and Cover Assembly

Hydronic Controls
Electrical Ratings, Contacts
(Full Load) (Locked Rotor) (Resistive) Pilot Duty Ratings
R4222B, R4222D, 12 A @ 120 Vac; 60 A @ 120 Vac: 20.8 A @ 120 Vac, Minimum: 3 VA @ 24 Vac, 120 Vac, & 480 Vac;
R4222N, R8222B, 6 A @ 208 Vac, 35 A @ 208 Vac, 208 Vac, 240 Vac, Maximum: 25 VA @ 24 Vac, 125 VA @ 120 Vac, 240 Vac, & 480 Vac;
R8222D, R8222N, 240 Vac, 277 Vac; 240 Vac, 277 Vac; 277 Vac; Resistive: 3 A @ 277 Vac (0.75 power factor);
R8222U, R8222V 3 A @ 480 Vac 18 A @ 480 Vac 10 A @ 480 Vac Powerpile: (Normally Open Contacts Only) 0.25 A @ 0.25 to 12 Vdc
R8228A 16 A @ 120 Vac; 96 A @ 120 Vac; 25 A @ 120 Vac, —
12 A @ 277 Vac; 72 A @ 208 Vac, 208 Vac, 240 vac,
18 A @ 208 Vac, 240 Vac, 277 Vac; 277 Vac;

Controls
240 Vac; 30 A @ 480 Vac 15 A @ 480 Vac

Water
5 A @ 480 Vac
R8228B 16/18 A @ 120 Vac; 96/72 A @ 120 Vac; 25 A @ 120 Vac; —
18 A @ 208 Vac, 72 A @ 208 Vac, 208 Vac, 240 Vac,
240 Vac; 240 Vac, 277 Vac; 277 Vac;
12 A @ 277 Vac; 30 A @ 480 Vac 12.5 A @ 480 Vac
5 A @ 480 Vac

Building Automation
R8228D 5.5 A @120 Vac, 15 A @ 120 Vac, 25 A @ 120 Vac; —
208 Vac, 240 Vac, 208 Vac, 240 Vac, 208 Vac, 240 Vac,
277 Vac; 277 Vac; 277 Vac;
3.0 A @ 480 VaC 8 A @ 480 Vac 12.5 A @ 480 Vac

* Product Number Coil Ratings Voltage Frequency Switching


* R4222B1082 120 V 50 Hz; 60 Hz SPDT
* R4222D1013 120 V 50 Hz; 60 Hz DPDT
* R4222D1021 208V; 240 V 50 Hz; 60 Hz DPDT

Components
Commercial
* R4222N1002 120 V 50 Hz; 60 Hz DPDT - Pilot Duty
* R8222B1067 24 Vac 50 Hz; 60 Hz SPDT
* R8222D1014 24 Vac 50 Hz; 60 Hz DPDT
* R8222N1011 24 Vac 50 Hz; 60 Hz DPDT - Pilot Duty
* R8222U1079 24 V 50 Hz; 60 Hz DPST N.O. (1 P&1 Pduty)
Pneumatic Controls

* R8222V1003 24 Vac 50 Hz; 60 Hz DPDT (1 P&1PDuty)


R8228A1006 24 V 50 Hz; 60 Hz SPST N.O.
* R8228B1012 24 Vac 50 Hz; 60 Hz SPDT
R8228D1018 24 Vac 50 Hz; 60 Hz DPST N.O.
* TRADELINE models • SUPER TRADELINE models
Industrial Combustion
Controls

70-6910 157
Relays
R4225; R8225 Fan Relay
Provide general purpose and heavy duty switching for
refrigeration and air conditioning equipment, appliances, vending
machines and similar applications.
• Molded terminal numbers and circuit diagram on top of relay provide
easy identification for wiring and checking system operation.
• Untaped coil assures cooler operation.
• Laminated magnet construction for higher efficiency.
• Base designed for easy replacement of competitive relays.
• Double quick-connect coil terminals.
• Plug compatible with Steveco 90-340 and Mars 90340.

Dimensions, Approximate: 2 11/16 in. high x 2 1/2 in. wide x 3 7/16 in. Approvals:
deep (68 mm high x 64 mm wide x 87 mm deep) Canadian Standards Association: Certified: File No. LR95329-1
Electrical Connections (main): Leadwires Underwriters Laboratories, Inc. UL Listed: File No. E14480, Vol. 1,
Temperature Rating: 115 F (46 C) Sec. 3, Guide No. NLDX
Accessories:
129384A Case and Cover Assembly

Electrical Ratings, Contacts


(Full Load) (Locked Rotor) (Resistive)
R4225A, N.O. 14.0A, N.C. 14.0A, Aux. 3.0A @ 120 Vac; N.O. 84.0 A, N.C. 84.0 A, Aux. 18.0 A @ 120 Vac; N.O. 16.0 A, N.C. 14.0 A, Aux. 3.0 A @ 120 Vac;
R8225A N.O. 8.0A, N.C., 7.0A, Aux. 2.0A @ 240 Vac N.O. 48.0 A, N.C. 42.0 A, Aux. 12.0 A @ 240 Vac N.O. 8.0 A, N.C. 7.0 A, Aux. 2.0 A @ 240 Vac
R8225D N.O. 14.0 A, Aux. 3.0 A @ 120 Vac; N.O. 84.0 A, Aux. 18.0 A @ 120 Vac; N.O. 16.0 A, Aux. 3.0 A @ 120 Vac
N.O. 8.0 A, Aux. 2.0 A @ 240 Vac N.O. 48.0 A, Aux. 12.0 A @ 240 Vac N.O. 8.0 A, Aux. 2.0 A @ 240 Vac

Product Number Coil Ratings Voltage Frequency Switching


R4225A1008 120 V 60 Hz SPDT, 1 N.O., 1 N.C.
* R8225A1017 24 Vac 60 Hz SPDT
R8225D1003 24 Vac 60 Hz DPST N.O.
* TRADELINE models • SUPER TRADELINE models

158 customer.honeywell.com 70-6910


Relays
R8229 Electric Heat Relay

Controls
Home
Normally Closed Relays And Contactors For Load Control
Systems.
• Close and leave load operating in case of wiring or control problem,
or relay malfunction.
• Consume no power while load is powered; require power only to
shed load.
• Operate directly from a pilot duty rated relay in the load control

Indoor Air Quality


system.

Dimensions in inches (millimeters)

Combustion Controls
Dimensions, Approximate: 2 3/16 in. high x 2 3/32 in. wide x 2 1/4 in.

Residential
1-5/8 (41) deep (56 mm high x 53 mm wide x 57 mm deep.)
Electrical Connections (main): #10 combination head screws
1/4 (6) (2) Temperature Rating: -40 F to +165 F (-40 C to +74 C)
Approvals:
CE: Approved
Canadian Standards Association: Recognized
Underwriters Laboratories, Inc. UL Component Recognized
3/16 (5) (2)

Hydronic Controls
1-17/32
(39)

5/16 (8)

Controls
Water
M16622A
7/32 (6)

Electrical Ratings, Contacts


(Full Load) (Locked Rotor) (Resistive)
7.0 A @ 120 Vac, 208 Vac, 240 Vac, 277 Vac 35 A @ 120 Vac, 208 Vac, 240 Vac, 277 Vac; 25 A @ 120 Vac, 208 Vac, 240 Vac, 277 Vac;

Building Automation
2.8 A @ 600Vac; 3.5 A @ 480 Vac 14 A @ 600 Vac; 17.5 A @ 480 Vac 10.0 A @ 600 Vac; 12.5 A @480 Vac

Product Number Coil Ratings Voltage Frequency Switching Includes


R8229A1005 24 Vac 60 Hz DPST —
• R8229A1021 24 Vac 60 Hz DPST Extra Mounting Hardware
* TRADELINE models • SUPER TRADELINE models

Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 159
Relays
R8330 Electric Furnace Sequencer
One control switches a fan and up to three elements on and off in
sequence.
• Isolated fan switch has positive interlock to assure fan is on when
the element is on, and fan is off when the element is off.
• Replaces any of the ten models in our line and many competitive
devices.
• Combination rating on the first element switch allows replacing
devices having fan and first element controlled by the same switch
without rewiring the furnace.
• Auxiliary switch controls a second R8330 in application with more
than three elements.
• Cycles ON within two minutes, OFF within four minutes.
• Ten-second minimum delay between stages (makes sequence and
break sequence.)
• Timings meet EEI-NEMA and ARI 280 Standards.
Dimensions, Approximate: 3 1/16 in. high x 4 13/16 in. wide x 2 11/32 Approvals:
in. deep (78 mm high x 122 mm wide x 60 mm deep.) Canadian Standards Association: Certified
Electrical Connections (main): terminals Underwriters Laboratories, Inc. UL Listed
Temperature Rating: -20 F to +150 F (-29 C to +66 C)

Electrical Ratings, Contacts


(Full Load) (Locked Rotor)
3/4 hp; 6.9 A @ 120 Vac, 208 Vac, 240 Vac; 3/4 hp; 41.4 A @ 120 Vac, 208 Vac, 240 Vac
1/3 hp; 7.2 A @ 120 vac; 4.9 A @ 277 Vac 1/3 hp; 43.2 a @ 120 Vac; 29.4 A @ 277 Vac

Product Number Coil Ratings Voltage Frequency


* R8330D1039 24 Vac 60 Hz
* TRADELINE models • SUPER TRADELINE models

R841 Electric Heating Relay


Use with two-wire, 24 Vac thermostat to control electric heating
equipment such as baseboard, ceiling cable and duct heaters.
• Operate with each cycle of the thermostat (4 to 6 cycles per hour).
• Each relay switches up to a 5,000 W load.
• Contacts make and break in about 75 seconds.
• Mount in any position.
• Includes 1/2 in. (13 mm) male conduit bushing.

Dimensions, Approximate: 3 7/8 in. high x 2 13/16 in. wide x 1 1/2 in.
deep (98 mm high x 71 mm wide x 38 mm deep)
Temperature Rating: -20 F to +150 F (-29 C to +66 C)
Approvals:
Canadian Standards Association: Certified
Underwriters Laboratories, Inc. UL Listed

Electrical Ratings, Contacts


(Full Load) (Locked Rotor) (Resistive)
14 A @ 120 Vac; 84 A @ 120 Vac; 22 A @ 120 Vac, 208 Vac, 240 Vac;
7.0 A @ 208 Vac, 240 Vac, 277 Vac 42 A @ 208 Vac, 240 Vac, 277 Vac 19 a @ 277 Vac

Coil Ratings Electrical Connections


Product Number Voltage Frequency Switching (main) Includes
R841C1029 240 V 50 Hz; 60 Hz SPST Terminals Enclosure w/conduit bushing.
R841C1151 600 Vac 50 Hz; 60 Hz SPST Leadwires Enclosure w/ conduit bushing and an integral
transformer.
* R841C1169 208 V; 240 Vac 50 Hz; 60 Hz SPST Leadwires Enclosure w/ conduit bushing and an integral
transformer.
* R841C1227 24 V 50 Hz; 60 Hz SPST Leadwires —
* R841D1036 24 V 50 Hz; 60 Hz SPST Leadwires Enclosure w/conduit bushing.
* R841E1068 24 V 50 Hz; 60 Hz SPST Leadwires Enclosure w/conduit bushing and integral
transformer; dual load.
* TRADELINE models • SUPER TRADELINE models

160 customer.honeywell.com 70-6910


Relays
ST82 Fan Manager

Controls
Home
Use in compressor-run air conditioning, heat pump systems and
heating-cooling systems. Delays the indoor blower shutoff after
the compressor has shut off.
• Eighty-second delay on break.
• Combination electronic time delay board and R8222 relay saves
wiring time.
• Molded terminal numbers and circuit diagram on top of relay and

Indoor Air Quality


letter-coded terminals on time delay board provide easy
identification for wiring and system checkout.
• Laminated magnet construction for high efficiency.
• Reduces stratification and saves energy.

Dimensions, Approximate: 2 7/32 in. high x 2 1/16 in. wide x 2 9/16 in. Approvals:

Combustion Controls
deep (56 mm high x 52 mm wide x 65 mm deep) CE: Approved
Electrical Connections (main): 1/4 in. quick-connect terminals Canadian Standards Association: Certified: File No. LR95329-17

Residential
Temperature Rating: -20 F to +150 F (-29 C to +66 C) Underwriters Laboratories, Inc. UL Listed: File No. MP466, Vol. 22,
Sec. 1, Guide No. MBPR2

Electrical Ratings, Contacts


(Full Load) (Locked Rotor) (Resistive)
12 A @ 120 Vac; 60 A @ 120 Vac; 15 A @ 120 Vac;

Hydronic Controls
3 A @ 480 Vac; 6 A @ 208 Vac, 240 Vac, 277 Vac 18 A @ 480 Vac; 35 A @ 208 Vac, 240 Vac, 277 Vac 15 A @ 208 Vac, 240 Vac, 277 Vac;
10 A @ 480 Vac

Product Number Coil Ratings Voltage Frequency Delay Timing Switching


* ST82D1004 24 Vac 50 Hz; 60 Hz 80 sec DPDT
* TRADELINE models • SUPER TRADELINE models

Controls
Water
Building Automation
Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 161
Relays Parts and Accessories
Relay Accessories
Product Number Description
129384A Case and Cover Assembly

Relay Parts
Product Number Description
135887 Bail Lock Down Assembly

135959 Relay Receptacle

162 customer.honeywell.com 70-6910


Relays Parts and Accessories
Relays Selection Guide

Controls
Home
Relays
Input
Voltage/ Electrical
Coil Full Load Dimensions (in.) H x Connections

Indoor Air Quality


Voltage Switching Product Number Amp Rating Frequency W X D (main) Special Features
DPST N.O. R8228D1018 5.5 A 1 7/8 x 2 5/32 x 2 3/8 Q —
DPDT (1 P&1PDuty) R8222V1003 A 1 7/8 x 2 5/32 x 2 3/8 Q —
DPDT - Pilot Duty R8222N1011 A 1 7/8 x 2 5/32 x 2 3/8 Q Pilot Duty
24 V DPDT R8222D1014 A 1 7/8 x 2 5/32 x 2 3/8 Q —
DPDT ST82D1004 A 2 7/32 x 2 1/16 x 2 9/16 Q 80 sec shut off

Combustion Controls
delay
12
SPDT R8222B1067 A 1 7/8 x 2 5/32 x 2 3/8 Q —

Residential
DPDT - Pilot Duty R4222N1002 A 1 7/8 x 2 5/32 x 2 3/8 Q —
120 V DPDT R4222D1013 A 1 7/8 x 2 5/32 x 2 3/8 Q —
SPDT R4222B1082 A 1 7/8 x 2 5/32 x 2 3/8 Q —
208V/240V DPDT R4222D1021 A 1 7/8 x 2 5/32 x 2 3/8 Q —
SPDT R8225A1017 B 2 11/16 x 2 1/2 x 3 7/16 L —

Hydronic Controls
24V
DPST N.O. R8225D1003 14 B 2 11/16 x 2 1/2 x 3 7/16 L —
120 V SPDT, 1 N.O., 1 N.C. R4225A1008 B 2 11/16 x 2 1/2 x 3 7/16 L —
24 V SPDT R8228B1012 18 A 1 7/8 x 2 5/32 x 2 3/8 Q —

Frequency: A - 60Hz/50Hz; B - 60Hz, C - 50 Hz SPST Single Pole Single Throw


Approvals: UL, CSA DPST Double Pole Single Throw

Controls
Water
Temp Rating: -20 F to +150 F; 115 F max for R8225 DPDT Double Pole Double Throw
Connectors: CHS - Combination Head Screw; L - Leadwires; Q - Quick connect; T - Terminals SPDT Single Pole Double Throw

Building Automation
Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 163
Electric Heat Sequencer Selection Guide
Electric Heat Sequencer Selection Guide

Electric Heat Relays


Input Full Load Electrical
Voltage/Coil Amp Dimensions (in.) Connections
Voltage Switching Product Number Rating Frequency H x W X D (main) Special Features
R8229A1005 B 2 3/16 x 2 3/32 x 2 1/4 CHS —
24V DPST 7
R8229A1021 B 2 3/16 x 2 3/32 x 2 1/4 CHS Extra Mounting Hardware
R841D1036 A 3 7/8 x 2 13/16 x 1 1/2 L 18A resistive @ 120/208/240VAC.
24V SPST Requires Transformer. Canada -
replaces R841D1028
R841C1169 A 3 7/8 x 2 13/16 x 1 1/2 L 18A resistive @ 120/208/240VAC.
208/240V SPST Integral Transformer. Canada -
replaces R841C1029
14
R841E1068 A 3 7/8 x 2 13/16 x 1 1/2 L 22A resistive @120/208/240VAC. Dual
240V SPST
Load/integral transformer
R841C1144 A 3 7/8 x 2 13/16 x 1 1/2 L 18A resistive @120/208/240VAC.
347V SPST
Integral Transformer. Canada
R841C1151 A 3 7/8 x 2 13/16 x 1 1/2 L 18A resistive @120/208/240VAC.
600V SPST
Integral Transformer. Canada

Electric Furnace Sequencer


Input Voltage/Coil Electrical Connections
Voltage Product Number Full Load Amp Rating Frequency Dimensions (in.) H x W X D (main)
24V R8330D1039 7.2 B 3 1/16 x 4 13/16 x 2 11/32 T

Electric Heat Contactor


Full Load Amp Electrical Connections
Input Voltage/Coil Voltage Switching Product Number Rating Dimensions (in.) H x W X D (main)
24V DPST R8246A1038 30 2-3/16 x 2-1/4 x 3-5/16 Q,S

Frequency: A - 60Hz/50Hz; B - 60Hz, C - 50 Hz SPST Single Pole Single Throw


Approvals: UL, CSA DPST Double Pole Single Throw
Temp Rating: -20 F to +150 F; 115 F max for R8225 DPDT Double Pole Double Throw
Connectors: CHS - Combination Head Screw; L - Leadwires; Q - Quick connect; T - Terminals SPDT Single Pole Double Throw

164 customer.honeywell.com 70-6910


Electric Heat Sequencer Selection Guide
Electric Heat Sequencer Selection Guide

Controls
Home
Electric Heat Sequencers
Timings - ON Timings - OFF
Product Number Switches Timings M1-M2 M3-M4 M5-M6 M7-M8 M9-M10 M1-M2 M3-M4 M5-M6 M7-M8 M9-M10

Indoor Air Quality


R24AA1008 1 1 1-20 — — — — 40-110 — — — —
R24AA3004 1 1 — — 30-90 — — — — 1-30 — —
R24BA1006• 2 1 1-20 1-20 — — — 40-110 40-110 — — —

R24BA3002• 2 1 — — 30-90 30-90 — — — 1-30 1-30 —

R24CB4007• 3 2 1-110 1-110 1-110 — — 1-110 1-110 1-110 — —

Combustion Controls
R24DB4005• 4 2 1-110 1-110 1-110 1-110 — 1-110 1-110 1-110 1-110 —

Residential
R24ED5007• 5 4 1-160 1-160 1-160 1-160 1-160 1-160 1-160 1-160 1-160 1-160

Heat Pump-Air Handler Model


WR Xref Product Number Switches Timings Heat Cool

Hydronic Controls
24A34-15 R24AA2006 1 1 1-25 75-95

Temperature: -50F to 165F


Terminations: [Solder or screw type 1/4” quick connect]
Ratings: Estimate - 25A Resistive and 14A Inductive at 120Vac
SPST: Single Pole Single Throw

Controls
Water
DPST: Double Pole Single Throw
SPDT: Single Pole Double Throw
DPDT: Double Pole Double Throw
Agency: UL/CSA
Table Notes:

Building Automation
*M1-M2 and M3-M4 are always first switches to turn ON and last to turn OFF. All other switches are random ON and random OFF
*R24ED5007 Switch contacts designated F1 - F2 instead of M1 - M2
*R24BB3428 is Double Pole Double Throw model.
*R24AA2006 is a Single Pole Double Throw model for Heat Pump Applications
* • These contacts switch simultaneously
ON Time: Elapsed time (min. to max.) to make contact after heater is energized
OFF Time: Elapsed time (min. to max.) to break contact after heater is de energized

Components
Commercial
Electric Heat Sequencer Cross Reference
Honeywell White-Rodgers SUPCO GEMLINE A1 T-O-D Mars
R24AA1008 24A34-1 Q101 GS101 TDR10 12S20 33841
Pneumatic Controls

R24AA3004 24A34-2 Q102 GS102 TDR15 12S20 33842


R24BA1006 24A34-3 Q103 GS103 TDR20 12S22 33844
R24BA3002 24A34-4 Q104 GS104 TDR25 12S22 33845
R24CB4007 24A34-5 Q105 GS105 TDR30 15S21 33832
R24DB4005 24A34-6 Q106 GS106 15S22 33833
R24ED5007 24A34-14 15S241 33848
Industrial Combustion

R24AA2006 24A34-15
Controls

70-6910 165
Fan Centers
R8239 Control Center
Include NEMA standard transformer for excellent voltage control.
Provide low voltage control of line voltage fan motors and auxiliary
circuits in heating, cooling or heating-cooling circuits.
• NEMA standard Type D transformer (included) powers low voltage
control systems.
• Provide overload protection for transformer.
• Convenient connections for thermostat, and heating-cooling
equipment wiring.
• Mount on standard 4 x 4 junction box.
• Can be mounted in any indoor location without additional enclosure.
• Relay is easily replaced without disturbing wiring.
• Include relay enclosures.

Dimensions, Approximate: 4 1/2 in. high, 4 3/16 in. wide,


3 3/32 in. deep (114 mm high, 106 mm wide, 79 mm deep) Electrical Ratings
Electrical Ratings (W): 12 W maximum
Coil Ratings (inrush): 20 VA maximum, 17 VA nominal. 120 Vac 240 Vac
Coil Ratings (sealed): 10 VA maximum, 9 VA nominal Full Load Locked Rotor Full Load Locked Rotor
Approvals: 12A 72A 6.9A 41.4A
Canadian Standards Association: Certified
NEMA Standard: NEMA Standard DC20-1992
Underwriters Laboratories, Inc. UL Listed

Power
Supply Power Supply Switching
Product Number Application Frequency Horsepower Voltage (Vac) (Secondary) Action Includes
* R8239A1052 For single-or two speed fan. 50 Hz; 60 Hz 3/4 HP 120 Vac 40 VA 26.5 V SPDT R8222B
• R8239B1076 For system with F50 Electronic 50 Hz; 60 Hz 3/4 HP 120 Vac: 50 VA 26.5 V DPDT R8222D
Air Cleaner humidifier and 208 Vac;
blower motor. 240 Vac
* TRADELINE models • SUPER TRADELINE models

R8285 Control Center


Provides low voltage control of line voltage fan motors and
auxiliary circuits in heating, cooling, or air conditioning systems.
• Transformer powers low voltage control systems and provides
overload protection.
• Low voltage terminal board provides convenient connections for
thermostat and heating/cooling equipment wiring.
• Mounts on standard 4 x 4 in. junction box.
• Relay is easily replaced without disturbing wiring.

Dimensions, Approximate: 4 3/16 in. high, 4 1/2 in. wide,


2 13/16 in. deep (106 mm high, 114 mm wide, 71 mm deep) Electrical Ratings
Electrical Ratings (W): 11 W maximum
120 Vac 240 Vac
Approvals: Full Load Locked Rotor Full Load Locked Rotor
Canadian Standards Association: Certified: File No. LR95329-17
Underwriters Laboratories, Inc. UL Component Recognized; File No. 12A 72A 6A 35A
E4436, Vol.15, Sec.1, Guide No.XAPX2

Power Power
Supply Supply Switching
Product Number Application Frequency Horsepower Voltage (Vac) (Secondary) Action Includes
* R8285A1048 For single-or two speed fan. 60 Hz 3/4 HP 120 Vac 40 VA 26.5 V SPDT R8222B
* R8285B1053 For "Total Comfort" applications 60 Hz 3/4 HP 120 Vac; 40 VA 26.5 V DPDT R8222D
with electronic air cleaner, 208 Vac;
humidifier and blower motor. 240 Vac
R8285D5001 For Hydronic Applications; use with 60 Hz 3/4 HP 120 Vac 50 VA 26.5 V DPST (One R8222U
SV9600 SmartValve™ System and Power Rated,
other systems that require 50 VA One Pilot Duty)
capacity.
* TRADELINE models • SUPER TRADELINE models

166 customer.honeywell.com 70-6910


Fan Center Selection Guide
Fan Center Selection Guide

Controls
Home
Fan Centers
Electrical
Electrical Ratings - Input Dimensions Main Secondary Special

Indoor Air Quality


Ratings- VA Voltage Switching Product Number NEMA (in.) H x W X D Connections Connections Frequency Features
DPDT R8239B1043 Yes 4 1/2 x 4 3/16 x L L A Super
3 3/32 Tradeline
DPST R8239D1007 Yes 4 1/2 x 4 3/16 x L L A —
3 3/32
DPST R8239D1015 Yes 4 1/2 x 4 3/16 x L L A Tradeline
40VA 120 Vac (1 Power, 3 3/32

Combustion Controls
1 Pilot)

Residential
SPDT R8239A1052 Yes 4 1/2 x 4 3/16 x L L A Tradeline
3 3/32
SPDT R8239A1003 Yes 4 1/2 x 4 3/16 x L L A —
3 3/32
120 Vac| DPDT R8239B1076 Yes 4 1/2 x 4 3/16 x L L A Super
50VA 240 Vac| 3 3/32 Tradeline
208 Vac

Hydronic Controls
SPDT R8285A1048 No 4 3/16 x 4 1/2 x L L A Tradeline
120 Vac
2 13/16
40VA 120 Vac| DPDT R8285B1053 No 4 3/16 x 4 1/2 x L L A Tradeline
240 Vac| 2 13/16
208 Vac
SPDT R8285A1006 No 4 3/16 x 4 1/2 x L L A —
2 13/16
50VA 120 Vac
DPDT R8285D5001 No 4 3/16 x 4 1/2 x L L A —
2 13/16
Frequency: A - 60Hz/50Hz; B - 60Hz

Controls
Water
Approvals: UL, CSA
Temp Rating: -20 F to +105 F
Connectors: L - Leadwires
Mounting: Standard 4 X 4 in. junction box

Building Automation
Supertradeline models include extra hardware.

Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 167
Transformers
AT120; AT140; AT150A,B; AT175A General Purpose Transformer
Provide power to 24 Vac circuits in heating/cooling control
systems. Intended for use in systems with predictable, uniform
loads. Can be used in any application that does not exceed the
listed ratings.
• Color-coded leadwires for primary connections and screw terminals
for secondary connections, fixed 1/4 inch (6 mm) male quick-
connects or color-coded leadwires for both primary and secondary,
are standard.
• Meet NEC Class 2 requirements.
• Meet Underwriters Laboratories Inc. Standard UL 1585 and are
AT120A identified. Class 2 not wet, Class 3 wet.
AT150A
Temperature Rating: -20 F to +105 F (-29 C to +41 C)
Frequency: 60 Hz
NEMA Rating
AT175A1008 only: NEMA type E
Approvals:
Canadian Standards Association: CSA Certified: A & B models.
Underwriters Laboratories, Inc. UL Listed: A,C,F models. File #
E14881
AT120B, AT140B, AT175A
AT140D, AT150B
AT140A

Dimensions in inches (millimeters)

PLATE OR OUTLET BOX MOUNTING PLATE


PLATE MOUNTED AT THE FOOT MOUNTED
MOUNTED AT CLAMP LAMINATIONS (3/4 ABOVE 3-3/8 (86)
ON END BELL (ALL PLATE MOUNTING) 3-1/16 (78) 1/8 (3)
ABOVE PLATE MOUNTING)
2-15/16 (76) 1-1/16 2 (51)
(27)
3-7/32
82 1/4
2-1/4 1/8 (6)
(57) (3) 4-3/16
(106)

2-3/8
(60) 3-3/8
2
(51) (86)
D

1-3/4
(44)
2-3/8 3 -1/4 (83)
5/16 (8)
(60)

M17509A

Electrical Connections
Electrical Ratings (main) Dimensions, Approximate
Voltage
Product Number Primary Secondary Output Primary Secondary Mounting (inch) (mm) Includes
AT120A1004 120 Vac, 27 V.O.C. 24 Vac 9 in. (2) screw Foot mounted, plate 2 7/8 in. high x 73 mm high x —
208 Vac, at 20 VA leadwires terminals mounted on 2x4 in. or 1 7/8 in. wide x 48 mm wide x
240 Vac 4x4 in. outlet box, clamp 2 15/16 in. deep 75 mm deep
mounted using outlet
box knockout, or panel
mounted
AT120B1028 120 Vac 27 V.O.C. 24 Vac 9 in. 9 in. leadwires Foot-mounted 1 11/16 in. high 43 mm high x Metal end
at 20 VA leadwires x 3 3/16 in. wide 81 mm wide x bells
x 1 3/4 in. deep 75 mm deep
AT140A1000 120 Vac 27 V.O.C. 24 Vac 9 in. (2) screw Foot mounted, plate 3 3/16 in. high x 81 mm high x Metal end
at 40 VA leadwires terminals mounted on 2x4 in. or 2 3/8 in. wide x 60 mm wide x bells
4x4 in. outlet box, clamp 3 1/8 in. deep 79 mm deep
mounted using outlet
box knockout, or panel
mounted
AT140A1018 120 Vac, 27 V.O.C. 24 Vac 9 in. (2) screw Foot mounted, plate 3 3/16 in. high x 81 mm high x Metal end
208 Vac, at 40 VA leadwires terminals mounted on 2x4 in. or 2 3/8 in. wide x 60 mm wide x bells
240 Vac 4x4 in. outlet box, clamp 3 1/8 in. deep 79 mm deep
mounted using outlet
box knockout, or panel
mounted

168 customer.honeywell.com 70-6910


Transformers

Controls
Electrical Connections

Home
Electrical Ratings (main) Dimensions, Approximate
Voltage
Product Number Primary Secondary Output Primary Secondary Mounting (inch) (mm) Includes
AT140B1016 120 Vac 27 V.O.C. 24 Vac 1/4 in. male 1/4 in. male Foot-mounted 1 11/16 in. high 43 mm high x Plastic end
at 40 VA quick- quick-connects x 3 1/2 in. wide 89 mm wide x caps

Indoor Air Quality


connects x 1 3/4 in. deep 75 mm deep
AT140B1206 120 Vac 27 V.O.C. 24 Vac 9 in. 9 in. leadwires Foot-mounted 1 11/16 in. high 43 mm high x Plastic end
at 40 VA leadwires x 3 1/2 in. wide 89 mm wide x caps
x 1 3/4 in. deep 75 mm deep
AT140B1214 120 Vac, 27 V.O.C. 24 Vac 9 in. 9 in. leadwires Foot-mounted 1 11/16 in. high 43 mm high x Plastic end
208 Vac, at 40 VA leadwires x 3 1/2 in. wide 89 mm wide x caps
240 Vac x 1 3/4 in. deep 75 mm deep
AT140D1012 120 Vac 27 V.O.C. 24 Vac 9 in 9 in. leadwires integral 4 x 4 in. 2 5/8 in. high x 67 mm high x Metal end

Combustion Controls
at 40 VA leadwires mounting plate fits 2 x 4 2 1/4 in. wide x 57 mm wide x bells
in. or 4 x 4 in. outlet box. 1 15/16 in. deep 49 mm deep

Residential
AT150A1007 120 Vac, 27.5 V.O.C. 24 Vac 9 in. (2) screw Foot mounted, plate 1 11/16 in. high 43 mm high x Metal end
208 Vac, at 50 VA leadwires terminals mounted on 2x4 in. or x 3 3/16 in. wide 81 mm wide x bells
240 Vac 4x4 in. outlet box, clamp x 1 3/4 in. deep 75 mm deep
mounted using outlet
box knockout, or panel
mounted
AT150B1146 120 Vac, — 24 Vac 9 in 9 in. leadwires Foot-mounted 1 11/16 in. high 43 mm high x —
208 Vac, at 50 VA leadwires x 3 1/2 in. wide 89 mm wide x

Hydronic Controls
240 Vac x 1 3/4 in. deep 75 mm deep
AT150B1252 277 Vac 27.5 V.O.C. 24 Vac 9 in. 9 in. leadwires Foot-mounted 1 11/16 in. high 43 mm high x Plastic end
at 50 VA leadwires with 1/4 in. x 3 1/2 in. wide 89 mm wide x caps
with 1/4 in. male quick- x 1 3/4 in. deep 75 mm deep
male quick- connects with
connects plastic (2) end
covers
AT175A1008 120 Vac, 27.5 V.O.C. 24 Vac 9 in. (2) screw Foot mounted, plate 3 3/16 in. high x 81 mm high x Metal end
208 Vac, at 75 VA leadwires terminals mounted on 2x4 in. or 2 3/8 in. wide x 60 mm wide x bells
240 Vac 4x4 in. outlet box, clamp 3 5/8 deep 92 mm deep
mounted using outlet

Controls
Water
box knockout, or panel
mounted

AT150F Circuit Breaker Transformer


Provide power to 24 Vac circuits in heating/cooling control
systems. Intended for use in systems with predictable, uniform

Building Automation
loads. Can be used in any application that does not exceed the
listed ratings.
• Rated at 50 VA.
• Color-coded leadwires for primary connections and screw terminals
for secondary connections, fixed 1/4 inch (6 mm) male quick-
connects or color-coded leadwires for both primary and secondary,
are standard.
• Meet NEC Class 2 requirements.
• Meet Underwriters Laboratories Inc. Standard UL 1585 and are
identified. Class 2 not wet, Class 3 wet.

Components
Commercial
Temperature Rating: -20 F to +105 F (-29 C to +41 C) Approvals:
Frequency: 60 Hz Canadian Standards Association: Certified: File No. LR95329-18
Includes: Button for manually resetting the circuit breaker and metal Underwriters Laboratories, Inc. UL Listed: File no. E14881, Guide no.
end bells. XOKV.
Electrical Connections (main)
Primary: 9 in. leadwires
Secondary: 9 in. leadwires
Pneumatic Controls

Electrical Ratings Dimensions, Approximate


Voltage
Product Number Primary Secondary Output Mounting (inch) (mm)
* AT150F1022 120 Vac, 27.5 V.O.C. 24 Vac at 50 VA Includes 1/2 14 NPSM conduit connector and lock nut 3 3/16 in. high x 81 mm high x
208 Vac, for mounting on plate or panel (not included) with 7/8 in. 2 3/16 in. wide x 56 mm wide x
240 Vac knockout, and feet for surface mount. 3 5/8 in. deep 93 mm deep
Industrial Combustion

* AT150F1030 208 Vac, 27.5 V.O.C. 24 Vac at 50 VA Includes 1/2 14 NPSM conduit connector and lock nut 3 3/16 in. high x 81 mm high x
277 Vac, for mounting on plate or panel (not included) with 7/8 in. 2 3/16 in. wide x 56 mm wide x
480 Vac knockout, and feet for surface mount. 3 5/8 in. deep 93 mm deep
Controls

* TRADELINE models • SUPER TRADELINE models

70-6910 169
Transformers
AT175F Circuit Breaker Transformer
Provide power to 24 Vac circuits in heating/cooling control
systems. Intended for use in systems with predictable, uniform
loads. Can be used in any application that does not exceed the
listed ratings.
• Rated at 75 VA.
• Color-coded leadwires for primary connections and screw terminals
for secondary connections, fixed 1/4 inch (6 mm) male quick-
connects or color-coded leadwires for both primary and secondary,
are standard.
• Meet NEC Class 2 requirements.
• Meet Underwriters Laboratories Inc. Standard UL 1585 and are
identified. Class 2 not wet, Class 3 wet.
Temperature Rating: -20 F to +105 F (-29 C to +41 C) Includes: Button for manually resetting the circuit breaker and metal
Frequency: 60 Hz end bells.
Electrical Connections (main) Approvals:
Primary: 9 in. leadwires Canadian Standards Association: CSA Certified: A & B models.
Secondary: 9 in. leadwires Underwriters Laboratories, Inc. UL Listed: A,C,F models. File #
E14881

Electrical Ratings Dimensions, Approximate


Voltage
Product Number Primary Secondary Output Mounting (inch) (mm)
* AT175F1023 120 Vac, 27.5 V.O.C. 24 Vac at Includes 1/2 14 NPSM conduit connector and lock nut for 3 3/16 in. high x 81 mm high x
208 Vac, 75 VA mounting on plate or panel (not included) with 7/8 in. knockout, 2 3/16 in. wide x 56 mm wide x
240 Vac and feet for surface mount. 3 15/16 in. deep 102 mm deep
* AT175F1031 208 Vac, 27.5 V.O.C. 24 Vac at Includes 1/2 14 NPSM conduit connector and lock nut for 3 3/16 in. high x 81 mm high x
277 Vac, 75 VA mounting on plate or panel (not included) with 7/8 in. knockout, 2 3/16 in. wide x 56 mm wide x
480 Vac and feet for surface mount. 3 15/16 in. deep 102 mm deep
* TRADELINE models • SUPER TRADELINE models

AT20; AT40 NEMA Standard Universal Stripped-Down Transformer


Power a 24V control system; for direct mounting, or horizontal or
vertical foot-mounting.
• Channel frame mounting feet and slots allow for the three mounting
positions.
• Color-coded leadwires for primary connections.
• Overload protection provided.
• Energy limiting, meet NEMA DC20-1992 Standard.
• Meet NEC Class 2 not wet, Class 3 wet and U.L. 1585 requirements.
• Mount within proper enclosure.

Temperature Rating: -20 F to +105 F (-29 C to +41 C) Approvals:


Frequency: 50 Hz; 60 Hz Canadian Standards Association: Certified
Underwriters Laboratories, Inc. UL Component Recognized.
Electrical Connections (main)
Primary: 9 in. color coded primary and secondary leadwires
Secondary: 9 in. color coded primary and secondary leadwires

Electrical Ratings Dimensions, Approximate


Voltage
Product Number Primary Secondary Output NEMA Rating Mounting (inch) (mm)
* AT20A1123 120 Vac 26.5 V.O.C. 24 Vac at 19 VA NEMA type B Channel Frame Mounting allows for 2 in. high x 50.8 mm high x
Direct, Horizontal, or Vertical Foot 2 1/4 in. wide x 57 mm wide x
mounting. 1 7/8 in. deep 47.6 mm deep
* AT40A1121 120 Vac 26.5 V.O.C. 24 Vac at 40 VA NEMA type D Channel Frame Mounting allows for 2 3/32 in. high x 53 mm high x
Direct, Horizontal, or Vertical Foot 2 5/8 in. wide x 67 mm wide x
mounting. 2 3/16 in. deep 56 mm deep
* AT40A1139 240 Vac 26.5 V.O.C. 24 Vac at 40 VA NEMA type D Channel Frame Mounting allows for 2 3/32 in. high x 53 mm high x
Direct, Horizontal, or Vertical Foot 2 5/8 in. wide x 67 mm wide x
mounting. 2 3/16 in. deep 56 mm deep
* TRADELINE models • SUPER TRADELINE models

170 customer.honeywell.com 70-6910


Transformers
AT72 NEMA Standard Transformer

Controls
Home
24V control circuit step-down transformer designed to power any
24V control system, including thermostats, gas valves and relays.
• Override protection provided.
• Color-coded leadwires for primary connections.
• Energy limiting, meets NEMA Standard DC20-1992.
• Transformer is marked NEMA Type D.
• Meets NEC Class 2 not wet, Class 3 wet and U.L. 1585

Indoor Air Quality


requirements.
• Mount within proper enclosure.

Temperature Rating: -20 F to +105 F (-29 C to +41 C)


Frequency: 50 Hz; 60 Hz
NEMA Rating: Type D
Approvals:
Canadian Standards Association: Certified

Combustion Controls
N.E.C. NEC Approved.
Underwriters Laboratories, Inc. UL Component Recognized.

Residential
Electrical
Electrical Ratings Connections (main) Dimensions, Approximate
Voltage
Product Number Primary Secondary Output Primary Secondary Mounting (inch) (mm)
AT72D1006 120 Vac 26.5 V.O.C. 24 Vac 9 in. (2) screw 4 x 4 in. plate-mounted, protruding 3 7/32 in. high x 81.8 mm high x

Hydronic Controls
at 40 VA leadwires terminals into junction box 2 7/32 in. wide x 56.4 mm wide x
(1 1/16 into plate x (27 mm into box x
2 in. above plate) 50.8 mm above
deep box) deep
AT72D1188 120 Vac 26.5 V.O.C. 24 Vac 9 in. 9 in. 4 x 4 in. plate mounted without 3 7/32 in. high x 81.8 mm high x
at 40 VA leadwires leadwires protruding into junction box. 2 7/32 in. wide x 56.4 mm wide x
2 15/16 in. deep 74.6 mm deep
• AT72D1683 120 Vac 26.5 V.O.C. 24 Vac 9 in. (2) screw Can be foot mounted, plate 3 7/32 in. high x 81.8 mm high x
at 40 VA leadwires terminals mounted on 4 x 4 in., 4 in. octagon, 2 7/32 in. wide x 56.4 mm wide x
or 2 x 4 in. electrical boxes 3 1/16 in. deep 77.8 mm deep
(transformer all above plate or 3/4

Controls
above plate); or clamp mounted via

Water
a junction box knockout.
• AT72D1691 208 Vac, 26.5 V.O.C. 24 Vac 9 in. (2) screw Can be foot mounted, plate 3 7/32 in. high x 81.8 mm high x
240 Vac at 40 VA leadwires terminals mounted on 4 x 4 in., 4 in. octagon, 2 7/32 in. wide x 56.4 mm wide x
or 2 x 4 in. electrical boxes 3 1/16 in. deep 77.8 mm deep
(transformer all above plate or 3/4
above plate); or clamp mounted via

Building Automation
a junction box knockout.
* TRADELINE models • SUPER TRADELINE models

Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 171
Transformers
AT87 NEMA Standard Transformer
Used primarily for powering 24V air conditioning circuits. Can also
be used in other applications that do not exceed the listed ratings.
• Meets NEC Class 2 not wet, Class 3 wet and UL 1585 requirements.
• Transformer marked NEMA Type E.
• Overload protection provided.
• Color-coded leadwires for primary connections.

Temperature Rating: -20 F to +105 F (-29 C to +41 C)


Frequency: 50 Hz; 60 Hz
NEMA Rating: NEMA type E
Approvals:
Canadian Standards Association: Certified
Underwriters Laboratories, Inc. UL Component Recognized.

Dimensions in inches (millimeters)

3-3/8 (86)

1/8 (3) 21/32 2-9/32 (58)


(17)

3/16 (5)
4-3/16
(106)
2-3/8 1/4 (6)
(60)

1-3/4
3-3/8 (45)
1/8
(3) (86)
2-7/32
(56)
3/16 (5)
2 (51)

7/32 (6)
21/32
1-1/4
5/16 (8) 3-1/4 (83) (17) M16623A
(32)
7/8 (22)

Electrical
Electrical Ratings Connections (main) Dimensions, Approximate
Voltage
Product Number Primary Secondary Output Primary Secondary Mounting (inch) (mm) Includes
AT87A1049 120 Vac 26.5 V.O.C. 24 Vac 12 in. 12 in. Foot-mounted 2 15/16 in. deep x 74.6 mm deep x Energy limiting
at 48 VA leadwires leadwires 2 7/32 wide 65.4 mm wide overload protection
• AT87A1106 120 Vac, 26.5 V.O.C. 24 Vac 13 in. (2) screw Foot mounted 2 15/16 in. deep x 74.6 mm deep x Built-in protection.
208 Vac, at 48 VA leadwires terminals or 4x4 in plate. 2 7/32 wide 65.4 mm wide Primary winding
240 Vac burnout.
AT87A1155 480 Vac 26.5 V.O.C. 24 Vac 12 in. 12 in. Foot-mounted 2 15/16 in. deep x 74.6 mm deep x Energy limiting
at 48 VA leadwires leadwires 2 7/32 wide 65.4 mm wide overload protection
AT87A1189 277 Vac 26.5 V.O.C. 24 Vac 12 in. 12 in. Foot-mounted 2 15/16 in. deep x 74.6 mm deep x Energy limiting
at 48 VA leadwires leadwires 2 7/32 wide 65.4 mm wide overload protection
* TRADELINE models • SUPER TRADELINE models

172 customer.honeywell.com 70-6910


Transformers
AT88 Transformer

Controls
Home
Powers 24 Vac air conditioning circuits and other applications that
do not exceed the listed ratings.
• Meets NEC Class 2 not wet, Class 3 wet and U.L. 1585
requirements.
• Overload protection provided.
• Color-coded leadwires for primary connections.

Indoor Air Quality


Dimensions in inches (millimeters) Temperature Rating: -20 F to +105 F (-29 C to +41 C)

Combustion Controls
Frequency: 50 Hz; 60 Hz
SIDE BOTTOM
Electrical Connections (main)

Residential
PRIMARY
3-5/16 (84) Primary: 12 in. leadwires
SECONDARY LEADWIRES
LEADWIRES (2,3 OR 4)
Secondary: 12 in. leadwires
23/32 23/32
3/16 (19) (19) Approvals:
(5) Canadian Standards Association: Certified
2-15/16 2-3/16
Underwriters Laboratories, Inc. UL Component Recognized.
(75) (56)
1-3/4 1-3/4
(45) (45)

Hydronic Controls
2-11/32
7/32
MOUNTING (60)
(6)
SCREW
HOLES (4) 2-23/32 M 994A
(69)

Electrical Ratings Dimensions, Approximate


(Primary (Secondary
Product Number Voltage) Voltage) (Output) Mounting (inch) (mm) Includes

Controls
Water
AT88A1005 120 Vac 26.5 V.O.C. 24 Vac at 75 VA Foot-mounted 2 15/16 in. high x 75 mm high Internally fused secondary for
2 3/16 in. wide x 56 mm wide x overload protection.
3 5/16 in. deep 84 mm deep
* AT88A1021 208 Vac, 240 Vac 26.5 V.O.C. 24 Vac at 75 VA Foot-mounted 2 15/16 in. high x 75 mm high Internally fused secondary for
2 3/16 in. wide x 56 mm wide x overload protection.
3 5/16 in. deep 84 mm deep

Building Automation
AT88A1047 480 Vac 26.5 V.O.C. 24 Vac at 75 VA Foot-mounted 2 15/16 in. high x 75 mm high Internally fused secondary for
2 3/16 in. wide x 56 mm wide x overload protection.
3 5/16 in. deep 84 mm deep
* TRADELINE models • SUPER TRADELINE models

Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 173
Transformer Selection Guide
Transformer Selection Guide

Transformers (NEMA Rated)


Second-
Electrical Main ary
Ratings- Electrical Ratings - Product Connect- Connect- Special
VA Input Voltage Number Mounting ions ions Frequency Dimensions (in.) H x W X D Features
19VA 120 Vac AT20A1123 F L L A 2 x 2 1/4 x 1 7/8
120 Vac AT40A1162 F L L A 2 3/32 x 2 5/8 x 2 3/16
120 Vac AT72D1006 P L S A 3 7/32 x 2 7/32 x (1 1/16 into x 2 in.
above plate)
120 Vac AT72D1089 F L S A 3 7/32 x 2 7/32 x 3 1/1

40VA 120 Vac AT72D1188 P L L A 3 7/32 x 2 7/32 x 2 15/1


120 Vac AT72D1683 M L S A 3 7/32 x 2 7/32 x 3 1/16
120 Vac AT72D1956 M L L A 3 7/32 x 2 7/32 x 3 1/16 Canada
208 Vac, 240 Vac AT72D1691 M L S A 3 7/32 x 2 7/32 x 3 1/16
208 Vac, 240 Vac AT72D1733 M L S A 3 7/32 x 2 7/32 x 3 1/16 Canada
277 Vac AT87A1189 F L L A 2 15/16 x 2 7/32 x 2 1/4
48VA
480 Vac AT87A1155 F L L A 2 15/16 x 2 7/32 x 2 1/4
50VA 120 Vac, 208 Vac, 240 Vac AT87A1106 M L S A 2 15/16 x 2 7/32 x 2 1/4

Transformers (Not NEMA Rated)


Secon-
Electrical Main dary
Ratings- Electrical Ratings - Input Product Conne- Conn- Dimensions (in.)
VA Voltage Number Mounting ctions ections Frequency HxWXD Special Features
120 Vac AT120B1028 F L L B 1 11/16 x 3 3/16 x 1 3/4
20VA
120 Vac, 208 Vac, 240 Vac AT120A1004 M L S B 2 7/8 x 1 7/8 x 2 15/16
120 Vac AT140A1000 M L S B 3 3/16 x 2 3/8 x 3 1/8
120 Vac AT140B1206 F L L B 1 11/16 x 3 1/2 x 1 3/4
40VA 120 Vac, 208 Vac, 240 Vac AT140A1018 M L S B 3 3/16 x 2 3/8 x 3 1/8
120 Vac, 208 Vac, 240 Vac AT140B1214 F L L B 1 11/16 x 3 1/2 x 1 3/4
208 Vac, 240 Vac AT140B1024 F L,Q L B 1 11/16 x 3 1/2 x 1 3/4
120 Vac, 208 Vac, 240 Vac AT150A1007 M L S B 1 11/16 x 3 3/16 x 1 3/4
120 Vac, 208 Vac, 240 Vac AT150B1146 F L L B 1 11/16 x 3 1/2 x 1 3/4
120 Vac, 208 Vac, 240 Vac AT150F1022 M L L B 3 3/16 x 2 3/16 x 3 5/8 Button for resetting
circuit breaker &
50VA metal end bells
208 Vac, 277 Vac, 480 Vac AT150F1030 M L L B 3 3/16 x 2 3/16 x 3 5/8 Button for resetting
circuit breaker &
metal end bells
277 Vac AT150B1252 F L,Q L,Q A 1 11/16 x 3 1/2 x 1 3/4
120Vac AT175B1055 F L L B 2 1/3 x 3 9/16 x 2 1/3
120 Vac, 208 Vac, 240 Vac AT175A1008 M L S B 3 3/16 x 2 3/8 x 3 5/8
120 Vac, 208 Vac, 240 Vac AT175F1023 M L L B 3 3/16 x 2 3/16 x 3 15/16 Button for resetting
circuit breaker &
metal end bells
75VA 208 Vac, 277 Vac, 480 Vac AT175F1031 M L L B 3 3/16 x 2 3/16 x 3 15/16 Button for resetting
circuit breaker &
metal end bells
120 Vac AT88A1005 F L L A 2 15/16 x 2 3/16 x 3 5/16
208 Vac, 240 Vac AT88A1021 F L L A 2 15/16 x 2 3/16 x 3 5/16
480 Vac AT88A1047 F L L A 2 15/16 x 2 3/16 x 3 5/16

174 customer.honeywell.com 70-6910


Oil Primaries Cross Reference
Oil Primaries Cross Reference

Controls
Home
Valve Blower Lock- Manual
On Off out Trip Lever
Ignition Delay Delay Time Alarm w/ LED White-Rodgers Direct Universal
Type (Sec) (Min) (Sec.) Contacts Indicator OEM Product Carlin Product Product Service Part Service Part

Indoor Air Quality


15 R7184A1075, 40200-02S 669-640,669-670 R7184A1026 R7184U1004
R7184A1000
30 R7184A1018 42230-02S 669-440,669-445, R7184A1034 R7184U1012
669-470,669-540
45 R7184A1042 R7184U1020
15 15 R7184B1032, R7184B1024 R7184U1004
R7184B1016
15 0.25 15 R7184P1080 R7184P1098 R7184U1004

Combustion Controls
Interrupted

15 0.5/ 15 Yes R7184P1031, 50200-02S, R7184U1004

Residential
2/4/6 R7184P1049, 602000-2S,
R7184P1056, 6020002S015120,
R7184P1064, 6020002S030015,
R7184P1072 6020002S030015,
6020002S030030,
6020002S030120,
6020002S030300,
6020002S030010

Hydronic Controls
30 0.5/ 30 Yes R7184U1012
2/4/6
45 0.5/ 45 Yes R7184U1020
2/4/6
15 Yes Yes R8184G1294 668-601, 668-670 R8184G4066 R7184U1004
30 Yes Yes R8184G1393 668-501 R8184G4074 R7184U1012
45 Yes R8184G1286, 48245-S 668-401, 6680415 R8184G4009 R7184U1020
Intermittent

R8184G1427
Yes Yes 668-430 R8184G4025 R7184U1020

Controls
Yes Yes (No R8184G4082 R7184U1020

Water
LED)
R8184M1002 668-441, 668-451, R8184M1051
668-454

Building Automation
Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 175
Oil Primaries
R7184A,B,U Interrupted Electronic Oil Primary
with a cad cell flame sensor, operates an oil burner and optional oil
valve. Can be used with both hydronic and forced air systems.
• Compatible with hydronic and forced air applications.
• Patented cad cell resistance readout.
• Available in 15-, 30-, and 45-second lockout times.
• Safe start check.
• Indicator light monitors burner flame status and system lockout.
• Uses proven flame detection and monitoring systems.
• Optional valve-on delay, blower-off delay models: 15 second, or
selectable 0 or 15 second valve-on delay.
• Zero time or selectable 0-, 2-, 4-, 6-minute blower-off delay.
• Oil valve control.
• Compatible with power venters without integral timers.
• Oil-resistant plastic cover for electronics.

Dimensions, Approximate: 4 5/32 in. long x 4 11/32 in. wide x 2 1/2 in.
high (105.4 mm long x 110.5 mm wide x 63.5 mm high)
Ignition Type: Interrupted
Temperature Range: -40 F to +147 F (-40 C to +64 C)
Line voltage, safety rated, control for residential oil fired burners Approvals:
used in boilers, forced air furnaces and water heaters. When used Underwriters Laboratories, Inc. UL and cUL Component Recognized

Electrical Rating, Contacts Alarm Load Ratings


(Full Load) (Locked Rotor) (Pilot Duty) (Resistive)
R7184A,B 7.4 A @ 120 Vac; 3.7 a @ 240 Vac 44.4 A @ 120 Vac; 22.2 A @ 240 Vac — —
R7184U 7.4 A @ 120 Vac; 3.7 a @ 240 Vac 44.4 A @ 120 Vac; 22.2 A @ 240 Vac 2 A @ 30 Vac 2A @ 30 Vac

Lead Length Timing,


Safety
Product Number (inch) (mm) Electrical Connections Switch Mounting Bracket
R7184A1026 10 in. 254 mm Burner motor, oil valve, ignition, cad cell, limit, 15 sec. Junction box on main burner
thermostat, alarm
R7184A1034 10 in. 254 mm Burner motor, oil valve, ignition, cad cell, limit, 30 sec. Mounts on standard 4 x 4 in. junction box
thermostat, alarm
R7184A1042 10 in. 254 mm Burner motor, oil valve, ignition, cad cell, limit, 45 sec. Mounts on standard 4 x 4 in. junction box
thermostat, alarm
R7184B1024 10 in. 152 mm Burner motor, oil valve, ignition, cad cell, limit, 15 sec. Junction box on main burner
thermostat, alarm
R7184U1004 10 in. 254 mm Burner motor, oil valve, ignition, cad cell, limit, 15 sec. Junction box on main burner
thermostat, alarm
R7184U1012 10 in. 254 mm Burner motor, oil valve, ignition, cad cell, limit, 30 sec. Junction box on main burner
thermostat, alarm
R7184U1020 10 in. 254 mm Burner motor, oil valve, ignition, cad cell, limit, 45 sec. Mounts on standard 4 x 4 in. junction box
thermostat, alarm

176 customer.honeywell.com 70-6910


Oil Primaries
R8184G Protectorelay® Oil Burner Control

Controls
Home
Provides automatic, nonrecycling control of an intermittent
ignition oil burner system.
• Controls oil burner, oil valve (if desired) and the ignition transformer
in response to a call for heat.
• Solid state flame sensing circuit.
• LED on terminal strip indicates system lockout.
• Remote lockout indication available on some models.

Indoor Air Quality


• Enclosed safety switch with external reset button.
• Manual trip lever opens safety switch for system maintenance.
• Mounts on standard 4 x 4 in. junction box; select models may be
mounted directly on burner housing.
• C554A Cadmium Sulfide Flame Detector and 24 Vac thermostat
required.

Combustion Controls
Dimensions, Approximate: 4 3/8 in. high x 4 1/8 in. wide x 2 1/2 in. Alarm Load Ratings: pilot duty: 75 VA @ 120/240 Vac, 50-60 Hz; 25
deep (111 mm high x 104 mm wide x 64 mm deep) VA @ 24V, 50-60 Hz; resistive: 1.5 A @ 120/240V, 50-60Hz; 3 A @ 24

Residential
Ignition Type: Intermittent V, 50-60 Hz
Temperature Range: -40 F to +130 F (-40 C to +54 C)
Approvals:
Mounting Bracket: For mounting on a standard 4 in. X 4 in. junction Canadian Standards Association: CSA Certified; File no. LR95329-1
box or direct mounting on burner housing. Underwriters Laboratories, Inc. UL Component Recognized; File no.
Electrical Rating, Contacts: full load: 7.4 A @ 120 Vac; 3.7 a @ 240 MP268, Vol. 35 Sec. 1,3
Vac; locked rotor: 44.4 A @ 120 Vac; 22.2 A @ 240 Vac

Timing,

Hydronic Controls
Product Number Safety Switch Comments Includes
* R8184G4009 45 sec. With LED for lockout indication, and manual trip lever on safety switch to assure —
burner shutdown during servicing.
* R8184G4025 45 sec. With LED for lockout indication, and manual trip lever on safety switch to assure Remote Alarm Power
burner shutdown during servicing.
* R8184G4066 15 sec. With LED for lockout indication, and manual trip lever on safety switch to assure —
burner shutdown during servicing.
* R8184G4074 30 sec. With LED for lockout indication, and manual trip lever on safety switch to assure —
burner shutdown during servicing.

Controls
Water
* R8184G4082 45 sec. With LED for lockout indication, and manual trip lever on safety switch to assure Alarm
burner shutdown during servicing. Includes remote alarm dry contacts.
* TRADELINE models • SUPER TRADELINE models

R8184M Protectorelay® Oil Burner Control

Building Automation
Operates the oil burner and oil valve (if desired) in response to a
call for heat from a low voltage control circuit.
• Ignition is on whenever the burner is on (intermittent ignition-also
called constant ignition).
• Solid state flame sensing circuit.
• External button to manually reset safety switch after lockout.
• Enclosed safety switch must be manually reset after safety
shutdown.
• R8184M includes 40 VA transformer and Y and G terminals for
connection of cooling equipment.
• Mounts on standard 4 x 4 in. junction box.

Components
Commercial
• C554A Cadmium Sulfide Flame Detector and a 24 Vac thermostat
required.

Pneumatic Controls

Dimensions, Approximate: 4 3/8 in. high x 4 1/8 in. wide x 2 1/2 in. Electrical Rating, Contacts:
deep (111 mm high x 104 mm wide x 64 mm deep) Full Load: 7.4 A @ 120 Vac; 3.7 a @ 240 Vac;
Ignition Type: Intermittent Locked Rotor: 44.4 A @ 120 Vac; 22.2 A @ 240 Vac
Temperature Range: -40 F to +130 F (-40 C to +54 C) Approvals:
Underwriters Laboratories, Inc. UL Component Recognized; File no.
MP268, guide no. MCCZ2

Timing, Safety
Industrial Combustion

Product Number Switch Mounting Bracket Description


* R8184M1051 45 sec. Mounts on standard 4 x 4 in. junction box Protectorelay® Oil Burner Control with 45 seconds lock out timing
Controls

* TRADELINE models • SUPER TRADELINE models

70-6910 177
Oil Primaries
RA116; RA117 Protectorelay® Controls
One-piece, stack-mounted oil burner primary controls that cycle
the burner on and shut down the burner on flame loss or system
malfunction.
• Combine a Protectorelay® unit for cycling the burner and a
Pyrostat® flame detector for sensing temperature changes of flue
gases up to 1000 F (556 C).
• Manual reset of safety switch required after ignition failure
completely shuts off main burner.
• Include manual trip safety switch to assure burner shutdown during
servicing.
• Mount with flange for mounting on curved or flat surfaces.
• Use with line voltage or 24 Vac Control Circuit.

Dimensions, Approximate: 6 in. high x 5 3/16 in. wide x 3 3/16 in.


deep (152 mm high x 132 mm wide x 81 mm deep)
Ignition Type: Intermittent
Approvals:
Canadian Standards Association: CSA Certified; File no. LR95329-1
Underwriters Laboratories, Inc. UL Listed; File no.MP268, Guide no.
MCCZ

Product Number Timing, Safety Switch Mounting Bracket


* RA116A1055 75 sec. Nominal Mount with flange for mounting on curved or flat surfaces.
* RA117A1047 75 sec. Nominal Mount with flange for mounting on curved or flat surfaces.
* TRADELINE models • SUPER TRADELINE models

Oil Primary Control Parts


Product Number Description
120320 Replacement Cell Assembly, 400-1600 Ohm Sensitivity
130367 Replacement Cell Assembly, 400-1000 Ohm Sensitivity
32611 Grommet (Bulk Mdse)
4074BJS Oil line mounting bracket assembly, including nut and screw

178 customer.honeywell.com 70-6910


Oil Systems Diagnostics
QS7100 Cad Cell Tester

Controls
Home
The QS7100F Flame Quality Monitor (FQM) is designed to be used
with any of the Honeywell Electronic Oil Primary Controls, such as
the R7184A,B,P, or U by simply connecting the devices together
with the communications cable supplied.
• When these two devices are installed as a system, the burner
properly adjusted and the Flame Quality Monitor (FQM) initialized,
the FQM provides continuous monitoring of the flame and gives

Indoor Air Quality


warning when the combustion process has changed from its original
operational state.
• This warning normally occurs three to five days before the primary
control would shut down on safety lockout after the FQM alarm.
Depending on the specific cause of the warning, the actual time may
be shorter or longer. Alarm contacts are un-powered and provided
both normally open (NO) and normally closed (NC) contacts to
match the alarm system, tank monitoring system or phone dialer to
which the FQM is connected.

Combustion Controls
• Typically, the FQM is attached as a zone to the home security
system or can be connected to a small alarm in the home. In either

Residential
case, the person responsible for monitoring the alarm function is
provided with directions on how to contact the appropriate oil service
dealer so that service can be scheduled at a mutually convenient
time.

Product Number Color Description Used With


QS7100D1003 Black Cad Cell Primary Tester R7184G, R8184 Cad Cell Primaries

Hydronic Controls
QS7100T Portable Tester/Analyzer
The QS7100F Flame Quality Monitor (FQM) is designed to be used Depending on the specific cause of the warning, the actual time may
with any of the Honeywell Electronic Oil Primary Controls, such as be shorter or longer. Alarm contacts are un-powered and provided
the R7184A,B,P, or U by simply connecting the devices together both normally open (NO) and normally closed (NC) contacts to
with the communications cable supplied. match the alarm system, tank monitoring system or phone dialer to
• When these two devices are installed as a system, the burner which the FQM is connected.
properly adjusted and the Flame Quality Monitor (FQM) initialized, • Typically, the FQM is attached as a zone to the home security
the FQM provides continuous monitoring of the flame and gives system or can be connected to a small alarm in the home. In either

Controls
warning when the combustion process has changed from its original case, the person responsible for monitoring the alarm function is

Water
operational state. provided with directions on how to contact the appropriate oil service
• This warning normally occurs three to five days before the primary dealer so that service can be scheduled at a mutually convenient
control would shut down on safety lockout after the FQM alarm. time.

Product Number Application Description Used With


QS7100T1004 Testing R8184 and R7184 Cad Cell Primaries. Portable Tester/Analyzer R7184G, R8184 Cad Cell Primaries

Building Automation
Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 179
Flame Detectors
C554 Cadmium Sulfide Flame Detector
Photoconductive flame sensing device for sequencing oil burner
systems.
• On flame failure, the light sensitive cadmium sulfide cell, in
conjunction with flame sensing circuitry, causes the Protectorelay®
control to shutdown the main oil burner.
• Glass-to-metal hermetic seal in plug-in cell prevents deterioration by
humidity, soot or oil fumes.

Dimensions, Approximate: 1 7/8 in. high x 1 in. long x 1/2 in. wide (47 Accessories:
mm high x 25 mm long x 13 mm wide) 4074BJS Oil line mounting bracket assembly, including nut and screw
CAD Cells: 130367 High Sensitivity CAD Cell 12 MA minimum
sensitivity at 2 ft. candles Replacement Parts
Temperature Range: 140 F (60 C) 120320 Replacement Cad Cell. 7.5 mA minimum sensitivity at 2 ft.
Mounting Bracket: Type R candles
130367 Replacement Cad Cell. 12.0 mA minimum sensitivity at 2 ft.
Approvals:
candles.
Canadian Standards Association: CSA Component Listed: File no.
LR95329-1
Underwriters Laboratories, Inc. UL Listed: File no. MP268, Vol. 39,
Sec. 1, Guide MCCZ

Lead Length
Product Number (inch) (mm) Electrical Connections Includes Used With
• C554A1463 60 in. 1524 mm leadwires: NEC Class 1; Includes 2 flag A, B, E, J and P mounting brackets R4166, R4184, R8182, R8184,
1/4 in. quick connects. and fuel line adaptor R8185, R8404, R8991, R7997
* C554A1794 60 in. 152.4 cm leadwires: NEC Class 1 Type "E" mounting bracket and fuel R4166, R4184, R8182, R8184,
line adaptor R8185, R8404, R8991, R7997
* TRADELINE models • SUPER TRADELINE models

A7184 Cad Call Primary Tester


The A7184 Cad Cell Primary Tester is a convenient on-the-job
tester that can be used for all R8184 and R7184 Cad Cell Primaries.
It lets the service technician check out the primary quickly and
easily by simply connecting it to the tester and plugging the tester
into a standard 120 or 240 volt ac electrical outlet. This is an
extremely rugged instrument with a minimum of electrical
components and switches to use. It’s an ideal carry-around that
should be in every service person’s tool kit.

Product Number Description Comments Used With


A7184A1008 Cad Cell Primary Tester 120 Vac R7184, R8184 Cad Cell Primaries.

180 customer.honeywell.com 70-6910


Magnetic Valves
V4046A,B Magnetic Valves

Controls
Home
For ON-OFF control of oil flow to domestic oil burner equipment.
• Power interruption closes the valve immediately.
• Mount directly to pipeline or on support bracket.

Indoor Air Quality


Combustion Controls
Description: For controlling the flow of oil in an oil line. Valve opens Materials (Body): Aluminum
with a time delay being energized. Valve closes on power failure. Mounting: Directly in pipe or on support bracket

Residential
Body Pattern: Straight through Pressure Ratings: 150 psi (1034.2 kPa); 300 psi (2068.4 kPa)
Dimensions, Approximate: 2 3/4 in. high x 1 5/8 in. wide x 2 5/8 in. Temperature Range: 32 F to 115 F (0 C to 46 C); 125 F max Fluid (54
deep (70 mm high x 41 mm wide x 67 mm deep) C max Fluid)
Current (max amps at rated Vac/Hz): 0.115 amps Type of Fuel: #2 fuel oil
Power Consumption: 8 W
Approvals:
Electrical Ratings: 120 Vac Canadian Standards Association: File no. LR95329-1
Frequency: 60 Hz Factory Mutual: Listed: Report 16960
Electrical Connections: Two 36-in. (914 mm) leadwires, 1/2 in. conduit

Hydronic Controls
Underwriters Laboratories, Inc. Listed: File no. MH1639, vol. 3, sec.
bushing 3, Guide no. YIOZ
Connection Type: NPT

Maximum Operating
Pipe Size Pressure
Product Number (inch) (mm) (psi) (kPa) Valve Opening Time Valve Closing Time Replacement Parts
V4046A1074 1/8 in. 3 mm 2068 kPA 300 psi 3 sec to 8 sec 1 sec maximum 116649A Coil Assembly
V4046B1049 1/8 in. 3 mm 2068 kPA 300 psi Open Immediately 1 sec maximum 116671A Coil Assembly

Controls
Water
Magnetic Valve Accessories
Product Number Description
116671A Replacement Coil Assembly for 120V, 60 Hz V4046

Building Automation
Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 181
Pressuretrol Controller
PA404 Pressuretrol Controller
The PA404 is a series 40 (2-wire, SPST) pressuretrol controller for
use in 24, 120, 240 or 277 volt control circuits or in self powered
(millivoltage) applications.
• The PA404A is a pressure actuated high limit, safety control for
steam heating boilers; it breaks an electrical circuit to shut down the
burner if steam pressure rises above a safe level.
• The PA404B is used with suspension-type unit heaters to make the
fan circuit when a pressure rise indicates the presence of steam.
• Each model contains an SPST MICRO SWITCH snap-acting switch.
• Sensitive pressure-actuated diaphragm expands or contracts with
pressure variations, moving a lever mechanism which operates the
snap switch.
• A screw on top of the case allows set point adjustment without
removing the cover.
• Differential is adjusted by means of a dial located inside the case.
Dimensions, Approximate: 4 15/32 in. high x 3 3/8 in. wide x 2 1/4 in. Pressure Ratings (Set Point): Recommended minimum set point is
deep (114 mm high x 86 mm wide x 58 mm deep) differential setting plus 1 1/2 psi.
Electrical Ratings: 0.25 A @ 0.25 to 12 Vdc Pressure Surge (max.): 50 psi (345 kPa)
120 Vac, Full Load: 8.0A Pressure Sensing Element: Stainless Steel diaphragm
120 Vac, Locked Rotor: 48.0A Adjustable Scale Range: 0.5 psi to 9 psi (3 kPA to 62 kPa)
120 Vac, Resistive: 8.3A Materials (Case): Gray enamel finish
240 Vac, Full Load: 5.1A Pipe Connections: 1/4 in. female pipe threads
240 Vac, Locked Rotor: 30.6A Operating Humidity Range (% RH): 95% RH, non-condensing
240 Vac, Resistive: 8.3A Maximum Ambient Temperature: 150 F (66 C)
277 Vac, Resistive: 7.2A Approvals:
sealed: 150 VA @ 277 Vac Canadian Standards Association: CSA Listed: File no. LR1620.
Differential Pressure Range: Additive or Subtractive: 1 to 5 psi Adj. Underwriters Laboratories, Inc. UL Listed: File no. MP466, Guide no.
(Additive or Subtractive: 7 to 35 kPa Adj.) MBPR.
Maximum Operating Pressure: 20 psi (137 kPa)

Adjustable Operating Pressure Range


Product Number Application (psi) (kPa) Switching Action Switch Type
PA404A1025 Safety control for steam 3 psi to 15 psi 21 kPa to 103 kPa Makes at set point minus differential on SPST snap-
heating boilers pressure fall; Breaks at set point on acting switch
pressure rise.
* PA404A1033 Safety control for steam 0.5 psi to 9.0 psi 3 kPa to 62 kPa Makes at set point on pressure fall; Breaks SPST snap-
heating boilers at set point plus differential on pressure acting switch
rise.
* PA404B1023 Used with suspension type 0.5 psi to 9.0 psi 3 kPa to 62 kPa Breaks at set point on pressure fall; Makes SPST snap-
unit heaters at set point plus differential on pressure acting switch
rise.
* TRADELINE models • SUPER TRADELINE models

182 customer.honeywell.com 70-6910


Fan and Limit Controllers
L4029 High Limit Controller

Controls
Home
L4029E Reset Limit Control opens a line or low voltage circuit if the
air temperature reaches a critical level at controller location. The
primary usage of the L4029E is as a fire thermostat in the duct
work of air conditioning and ventilating systems. If the circulated
air reaches a temperature indicative of fire, the limit control shuts
off the fan, preventing the fan from contributing to the spread of
fire. It is also suitable for use with any warm air furnace to provide

Indoor Air Quality


positive lockout of the burner in the event of fan failure.
• Shuts off the fan when air temperature is indicative of fire.
• Internal snap-acting switch actuated by a bimetal strip inserted
directly into the air stream responds rapidly to temperature changes.
• Requires manual reset.

Dimensions in inches (millimeters)


Dimensions, Approximate:

Combustion Controls
2-5/16 (59) 3 3/4 in. high x 2 5/16 in. wide x 2 in. deep excluding element.
15/16 1-3/16 (95 mm high x 59 mm wide x 51 mm deep excluding element.)

Residential
(24) (30)
Maximum Ambient Temperature:
1 Switch: 190F; Sensing Element: 350 F
1-23/32 (Switch: 88 C; Sensing Element: 177 C)
(44)
3/16 Element Insertion Length: 3 in. (76 mm)
1-7/16 (5) 2-5/8
(37) (67) Electrical Rating Limit:
3/8 DIA. Full Load: 5 A @ 240 Vac; 10 A @ 120 Vac; 2 A @ 30 Vac
(10) 3-7/32
(82)
Locked Rotor: 30 A @ 240 Vac; 60 A @ 120 Vac

Hydronic Controls
15/16 Pilot Duty: 0.25 A @ 0.25 to 12 Vdc
(24) 3-3/4
1-7/16 1/2
(95) Approvals:
(37) (13) Canadian Standards Association: Certified: File No. LR95329-5
1-25/32
1/16 Underwriters Laboratories, Inc. Listed: File No. MP466, Vol. 8, Guide
(2)
(45) No. MBPR2

7/16 1-7/16 7/16


(11) (37) (11) 3/16
(5)

Controls
Water
2-3/4
(70)

Building Automation
7/32 1-9/16
(6) (40) 3-1/4 (83)
11/16
(17)
1 3/16 (5) DIAMETER MOUNTING HOLES L4029E WITH CASE AND COVER.
M27077

Components
Commercial
High Limit
Product Number Stop Switching Action
L4029E1011 135 F Normally closed SPST switch opens on temperature rise to the set point. Switch must be manually reset to operate.
L4029E1029 200 F Normally closed SPST switch opens on temperature rise to the set point. Switch must be manually reset to operate.
L4029E1045 240 F Normally closed SPST switch opens on temperature rise to the set point. Switch must be manually reset to operate.
Pneumatic Controls

* L4029E1219 165 F Normally closed SPST switch opens on temperature rise to the set point. Switch must be manually reset to operate.
* L4029E1227 125 F Normally closed SPST switch opens on temperature rise to the set point. Switch must be manually reset to operate.
* TRADELINE models • SUPER TRADELINE models
Industrial Combustion
Controls

70-6910 183
Fan and Limit Controllers
L4064 Fan and Limit Controllers
For control of high limit and fan motor in all types of forced air
heating systems.
• Three wiring terminal options available for easy installation:
• Push-in receptacles for stripped wire.
• Female receptacles for 1/4 in. male flag connectors.
• Field add-on screw terminals.
• Controls adapt to many competitive mounting holes in replacement
applications.
• Available in a variety of fan and high limit setting ranges.
• L4064B,W models have manual fan switch that overrides fan control
to keep fan running continuously.
• TRADELINE models with mounting adapters for easy installation
and strain relief bushings to protect wiring from field abuse.

Dimensions in inches (millimeters) Application: Forced warm air heating systems


Operating Temperature Range: -40 F to +190 F (-40 C to +88 C)
5/16 Maximum Ambient Temperature: Switch: 190 F; Sensing Element:
2-3/8 (60) (8) 350 F (Switch: 88 C; Sensing Element: 177 C)
Differential Temperature: High limit 25 F (High limit 14 C)
1/2 (13) High Limit Temperature Range: 100 F to 250 F (38 C to 121 C)
Fan-off Stop: 100 F
7/16 (12) (2)
Fan-on Stop: 125 F
High Limit Stop: 200 F
Switching Action: Fan switch makes and high limit switch breaks on
temperature rise.
3-1/4 Pilot Duty: 0.25 A @ 0.25 to 12 Vdc; 2 A @ 24 Vac
(83)
Electrical Rating Fan
3/4 (19)
ELEMENT 4-5/16 Full Load: 14 A @ 120 Vac; 7 A @ 240 Vac
(109) Locked Rotor: 84 A @ 120 Vac; 42 A @ 240 Vac
Electrical Rating Limit
Full Load: 8 A @ 120 Vac; 4 A @ 240 Vac
Locked Rotor: 48 A @ 120 Vac; 24 A @ 240 Vac
1/2
(13)
3/8 (9) (2) Approvals:
Canadian Standards Association: Certified: File No. LR1622
Underwriters Laboratories, Inc. Listed File LR1322-336 and -323
7/32
1-3/16
(30)
(6) (4) Accessories:
3 (76) 129250AA Double wing mounting flange assembly for Fan and Limit
Control L4064
NOTE: OVERALL DEPTH WITH FAN SWITCH IS 2 INCHES (51MM);
MODELS LESS FAN SWITCH ARE 1-5/8 INCHES (41MM).

Element Insertion
Length Fan-off Range Fan-on Range
Product Number (inch) (mm) (F) (C) (F) (C) Timing Mounting Comments
• L4064B1451 11 1/2 in. 292 mm 50 F to 10 C to 65 F to 18 C to — Rigid bracket Turns fan on and off according to plenum
200 F 93 C 215 F 102 C temperature. With helical bimetal sensing
element. High limit stop set at 200F (93 C).
With manual fan switch. Deluxe cover.
Replaces L4064A,B,E.
• L4064B1469 5 in. 127 mm 50 F to 10 C to 65 F to 18 C to — Rigid bracket Turns fan on and off according to plenum
200 F 93 C 215 F 102 C temperature. With helical bimetal sensing
element. High limit stop set at 200F (93 C).
With manual fan switch. Deluxe cover.
Replaces L4064A,B,E.
* L4064B2210 11 1/2 in. 292 mm 50 F to 10 C to 65 F to 18 C to — Surface Turns fan on and off according to plenum
200 F 93 C 215 F 102 C temperature. With helical bimetal sensing
element. High limit stop set at 200F (93 C).
With manual fan switch. Small case and
cover. Replaces L4064A,B,E.
* L4064B2228 5 in. 127 mm 50 F to 10 C to 65 F to 18 C to — Surface Turns fan on and off according to plenum
200 F 93 C 215 F 102 C temperature. With helical bimetal sensing
element. High limit stop set at 200F (93 C).
With manual fan switch. Small case and
cover. Replaces L4064A,B,E.
* L4064B2236 8 in. 203 mm 50 F to 10 C to 65 F to 18 C to — Surface Turns fan on and off according to plenum
200 F 93 C 215 F 102 C temperature. With helical bimetal sensing
element. High limit stop set at 200F (93 C).
With manual fan switch. Small case and
cover. Replaces L4064A,B,E.
* TRADELINE models • SUPER TRADELINE models

184 customer.honeywell.com 70-6910


Fan and Limit Controllers

Controls
Element Insertion

Home
Length Fan-off Range Fan-on Range
Product Number (inch) (mm) (F) (C) (F) (C) Timing Mounting Comments
* L4064W1080 5 in. 127 mm 50 F to 10 C to 20 to 90 20 to 90 20 to 90 Surface Turns fan on and off according to plenum
200 F 93 C sec. after sec. after sec. after mounting or temperature. With helical bimetal sensing
call for call for call for bracket (rigid element. High limit stop set at 200F (93 C).
heat heat heat or swivel) Jumper in. With timed on fan feature and

Indoor Air Quality


manual fan switch. Replaces L4064T, Y.
* L4064W1098 8 in. 203 mm 50 F to 10 C to 20 to 90 20 to 90 20 to 90 Surface Turns fan on and off according to plenum
200 F 93 C sec. after sec. after sec. after mounting or temperature. With helical bimetal sensing
call for call for call for bracket (rigid element. High limit stop set at 200F (93 C).
heat heat heat or swivel) Jumper in. With timed on fan feature and
manual fan switch. Replaces L4064T, Y.
* L4064W1106 11 1/2 in. 292 mm 50 F to 10 C to 20 to 90 20 to 90 20 to 90 Surface Turns fan on and off according to plenum
200 F 93 C sec. after sec. after sec. after mounting or temperature. With helical bimetal sensing
call for call for call for bracket (rigid element. High limit stop set at 200F (93 C).

Combustion Controls
heat heat heat or swivel) Jumper in. With timed on fan feature and
manual fan switch. Replaces L4064T, Y.

Residential
* TRADELINE models • SUPER TRADELINE models

L4064K Airstat Fan Safety Cutoff Controller


The L4064K is a manual reset fan safety cutoff switch used in all
types of heating, ventilating and air conditioning system to shut

Hydronic Controls
down fan operation.
• Three wiring terminal options available for easy installation:
• Push-in receptacles for stripped wire.
• Female receptacles for 1/4 in. male flag connectors.*Field add-on
screw terminals.
• Controls adapt to many competitive mounting holes in replacement
applications.
• Must be manually reset before the fan can resume operation.

Controls
Water
Application: Heating, ventilating and air conditioning systems Electrical Rating Limit
Dimensions, Approximate: Full Load: 8 A @ 120 Vac; 4 A @ 240 Vac
4 9/32 in. high x 3 in. wide x 13 3/32 in. deep excluding element Locked Rotor: 48 A @ 120 Vac; 24 A @ 240 Vac
(109 mm high x 76 mm wide x 333 mm deep excluding element) Pilot Duty: 0.25 A @ 0.25 to 12 Vdc; 2 A @ 24 Vac

Building Automation
Operating Temperature Range: 50 F to 165 F (10 C to 74 C) Approvals:
Maximum Ambient Temperature: Canadian Standards Association: Certified: File No. LR1622
Switch: 190 F; Sensing Element: 350 F Underwriters Laboratories, Inc. Listed File MP466, Guide MBPR
(Switch: 88 C; Sensing Element: 177 C)
Mounting: Flush mount, or rigid bracket, or swivel Accessories:
129250AA Double wing mounting flange assembly for Fan and Limit
Control L4064

Element Insertion
Length High
Limit

Components
Commercial
Product Number (inch) (mm) Stop Switching Action Comments
L4064K1006 11 1/2 in. 292 mm 167 F SPST fan safety cutoff switch breaks on temperature Turns fan off according to high limit stop
rise and requires a manual reset to remake. temperature. High limit stop set at 167F
(75 C). Jumper out.
L4064K1014 11 1/2 in. 292 mm 165 F SPST fan safety cutoff switch breaks on temperature Turns fan off according to high limit stop
rise and requires a manual reset to remake. temperature. High limit stop set at 167F
(75 C). Jumper out.
Pneumatic Controls

Fan and Limit Control Accessories


Product Number Description Used With
110265A Mounting Flange Assembly for Fan and Limit Control Limit stop Tool
196722 Limit stop adjusting tool for L4064
Industrial Combustion
Controls

70-6910 185
Aquastat Controllers
L4006; L6006 Aquastat® Controller
Aquastat® Controllers are immersion type devices for limiting or
regulating the temperature of liquids in boilers, storage tanks, and
other applications where temperature control is required.
• Totally enclosed Micro Switch® snap-acting switches operate on
temperature rise to setpoint.
• Visible control point scale and external adjustment screw permit
easy setting.
• Horizontal or vertical insertion of the sensing element.
• Direct or well immersion of the sensing element.
• Models available for strap-on mounting.
• Remote bulb model may be used to sense air temperature in ducts
and in outside air sensing applications.
• TRADELINE models include heat-conductive compound.
• Select models have wells.

Dimensions in inches (millimeters) Case Dimensions: 5 5/8 in. high x 2 in. wide x 2 1/8 in. deep
(143 mm high x 51 mm wide x 54 mm deep)
1 (25) Bulb Size: 3/8 in. x 2 7/8 in. (10 mm x 73 mm) copper
Maximum Ambient Temperature: 150 F (66 C)
KNOCKOUT FOR 3/4 (19 )
5/16 CONDUIT ON ALL MODELS. SIMILAR Approvals:
(8) KNOCKOUT ON BOTTOM FOR American Gas Association IAS: AGA Certified
HORIZONTAL INSERTION AND Canadian Standards Association: Certified: File No. LR95329-1
REMOTE BULB MODELS.
Underwriters Laboratories, Inc. UL Component Recognized: File No.
MP466, Vol. 6, Sec.1, Guide No. MBPR2

Product Electrical Ratings


2 (51) 3/16 2-1/8 (54)
(5) Number (Full Load) (Locked Rotor) (Millivolt)
L4006A1009 8A @ 120 Vac; 48A @ 120 Vac; 0.25 A @ 0.25
L4006A1017 5.1A @ 240 Vac 30.6A @ 240 Vac to 12 Vdc
L4006A1132
L4006A1678
L4006A1959 2.6A @ 120 Vac; 15.6A @ 120 Vac; —
5-5/8 1.3A @ 240 Vac 7.8A @ 240 Vac
(136) L4006A1967 8A @ 120 Vac; 48A @ 120 Vac; 0.25 A @ 0.25
L4006A2007 5.1A @ 240 Vac 30.6A @ 240 Vac to 12 Vdc
L4006B1007
L4006B1155
L4006B1163
RESET L4006E1067 8A @ 120 Vac; 48A @ 120 Vac;
BUTTON
L4006E1091 1.3A @ 240 Vac 30.6A @ 240 Vac
1-7/8 (L4006E,
(48) L4008E L4006E1109 —
3/4 3/4
ONLY)
(19) (19) L4006E1117 —
L4006E1125 8A @ 120 Vac; 48A @ 120 Vac; 0.25 A @ 0.25
KNOCKOUT FOR 3/4 (19)
ELEMENT
L4006H1004 1.3A @ 240 Vac 30.6A @ 240 Vac to 12 Vdc
FOR VERTICAL 11/16
CONDUIT ON VERTICAL
INSERTION MODELS ONLY
IMMERSION (18) L6006A1004 8A @ 120 Vac; 48A @ 120 Vac;
L6006A1012 5.1A @ 240 Vac 30.6A @ 240 Vac
ELEMENT FOR HORIZONTAL IMMERSION
M8957A L6006A1145
L6006A1244
L6006C1018
L6006C1059

Operating
Temperature Differential
Range Temperature Well Spud Size Capillary Length
Product Number Application (F) (C) (F) (C) (inch) (mm) (inch) (mm) Switching Action Mounting Includes
L4006A1009 High or Low 100 F to 38 C to 5 F 3 C fixed 1/2 in. 13 mm 1 1/2 in. 38 mm SPST, contacts break Horizontal or 1/2 in. well - 123869A
limit 240 F 116 C Fixed NPT NPT on temperature rise. Vertical
L4006A1017 High or Low 100 F to 38 C to 5 F to 3 C to 1/2 in. 13 mm 1 1/2 in. 38 mm SPST, contacts break Horizontal or 1/2 in. well - 123869A
limit 240 F 116 C 30 F adj. 17 C adj. NPT NPT on temperature rise. Vertical
L4006A1132 High or Low 100 F to 38 C to 5 F 3 C fixed 3/4 in. 19 mm 3 in. 76 mm SPST, contacts break Horizontal or Stop factory-set at 160 F
limit 240 F 116 C Fixed NPT NPT on temperature rise. Vertical (71 C);
3/4 in. well - 123871A
* TRADELINE models • SUPER TRADELINE models

186 customer.honeywell.com 70-6910


Aquastat Controllers

Controls
Operating

Home
Temperature Differential
Range Temperature Well Spud Size Capillary Length
Product Number Application (F) (C) (F) (C) (inch) (mm) (inch) (mm) Switching Action Mounting Includes
* L4006A1678 High or Low 100 F to 38 C to 5 F to 30 3 C to — — 3 in. 76 mm SPST, contacts break Horizontal or Heat-conductive
limit 240 F 116 C F adj. 17 C adj. on temperature rise. Vertical compound; Stop factory-
set at 240 F (116 C)

Indoor Air Quality


* L4006A1959 High or Low 40 F to 4 C to 5F 3 C fixed — — 3 in. 76 mm SPST, contacts break Horizontal or Heat-conductive
limit 180 F 82 C Fixed on temperature rise. Vertical compound
* L4006A1967 High or Low 100 F to 38 C to 5 F to 3 C to 1/2 in. 13 mm 1 1/2 in. 38 mm SPST, contacts break Horizontal or Stop factory-set at 240 F
limit 240 F 116 C 30 F adj. 17 C adj. on temperature rise. Vertical (116 C);
1/2 in. well - 123869A
L4006A2007 High or Low 100 F to 38 C to 5 F to 3 C to — — 3 in. 76 mm SPST, contacts break Horizontal —
limit 240 F 116 C 30 F adj. 17 C adj. on temperature rise.
L4006B1007 Circulator 100 F to 38 C to 5 F 3 C fixed 1/2 in. 13 mm 1 1/2 in. 38 mm SPST, contacts make Horizontal or 1/2 in. well - 123869A

Combustion Controls
240 F 116 C Fixed on temperature rise. Vertical

Residential
* L4006B1155 Circulator 100 F to 38 C to 5 F to 3 C to — — 3 in. 76 mm SPST, contacts make Horizontal or Heat-conductive
240 F 116 C 30 F adj. 17 C adj. on temperature rise. Vertical compound; Stop factory-
set at 240 F (116 C)
L4006B1163 Circulator 100 F to 38 C to 5 F to 3 C to — — 3 in. 76 mm SPST, contacts make Horizontal or —
240 F 116 C 30 F adj. 17 C adj. on temperature rise. Vertical
* L4006E1067 High Limit; 130 F to 54 C to Manual Manual — — 3 in. 76 mm SPST, contacts break Horizontal or Well adapter; Stop
Manual 270 F 132 C Reset Reset on temperature rise. Vertical factory-set at 250 F
Reset (121 C); Heat-conductive

Hydronic Controls
compound
L4006E1091 High Limit; 130 F to 54 C to Manual Manual — — 3 in. 76 mm SPST, contacts break Horizontal or —
Manual 270 F 132 C Reset Reset on temperature rise. Vertical
Reset
L4006E1109 High Limit; 130 F to 54 C to Manual Manual — — 1 1/2 in. 38 mm to SPST, contacts break Horizontal or —
Manual 270 F 132 C Reset Reset to 3 in. 76 mm on temperature rise. Vertical
Reset
L4006E1117 High Limit; 100 F to 38 C to Manual Manual 3/4 in. - 19 mm - 1 1/2 in. 38 mm SPST, contacts break Horizontal or 3/4 in. well - 123870A
Manual 240 F 116 C Reset Reset 14 NPT 14 NPT on temperature rise. Vertical
Reset

Controls
Water
L4006E1125 High Limit; 100 F to 38 C to Manual Manual — — 3 in. 76 mm SPST, contacts break Horizontal or —
Manual 200 F 93 C Reset Reset on temperature rise. Vertical
Reset
* L4006H1004 High Limit; 100 F to 38 C to Manual Manual — — 1 1/2 in. 38 mm SPST, contacts break Horizontal or Bracket for strap-on
strap-on 240 F 116 C Reset Reset on temperature rise. Vertical mounting; Heat-
mounting on conductive compound;
well mount. Stop factory-set at 240 F

Building Automation
(116 C)
L6006A1004 Circulator 100 F to 38 C to 5 F 3C 1/2 in. 13 mm 1 1/2 in. 38 mm SPDT Horizontal or 1/2 in. well - 123869A
Control and 240 F 116 C Vertical
High Limit or
Low Limit
L6006A1012 Circulator 100 F to 38 C to 5 F to 3 C to 1/2 in. 13 mm 1 1/2 in. 38 mm SPDT Horizontal or 1/2 in. well - 123869A
Control and 240 F 116 C 30 F adj. 17 C adj. Vertical
High Limit or
Low Limit
• L6006A1145 Circulator 100 F to 38 C to 5 F to 3 C to — — 3 in. 76 mm SPDT Horizontal Heat-conductive
Control and 240 F 116 C 30 F adj. 17 C adj. compound; Stop factory-

Components
Commercial
High Limit or set at 240 F (116 C)
Low Limit
L6006A1244 Circulator 100 F to 38 C to 5 F to 3 C to — — 3 in. 76 mm SPDT Horizontal or —
Control and 240 F 116 C 30 F adj. 17 C adj. Vertical
High Limit or
Low Limit
* L6006C1018 Circulator 65 F to 18 C to 5 F to 3 C to — — — — SPDT Horizontal or Stop factory-set at 200 F
Pneumatic Controls

Control and 200 F 93 C 30 F adj. 17 C adj. Vertical or (93 C)


High Limit or Strap-on-
Low Limit mounting
L6006C1059 Circulator 65 F to 18 C to 5 F to 3 C to — — — — SPDT Horizontal or Stop factory-set at 200 F
Control and 200 F 93 C 30 F adj. 17 C adj. Vertical (93 C)
High Limit or
Low Limit
* TRADELINE models • SUPER TRADELINE models
Industrial Combustion
Controls

70-6910 187
Aquastat Controllers
L4008; L6008 Remote Bulb Controller
Aquastat® Controllers are immersion type devices for limiting or
regulating the temperature of liquids in boilers, storage tanks, and
other applications where temperature control is required.
• Remote temperature sensing element detects and responds rapidly
to temperature changes.
• Totally enclosed Micro Switch® snap-acting switch.
• Visible control point scale and external adjustment screw permit
easy setting.
• Horizontal or vertical mounting of the remote element into boiler,
tank, or other container.
• Case mounts to a vertical surface.

Dimensions in inches (millimeters)


Case Dimensions: 5 5/8 in. high x 2 in. wide x 2 1/8 in. deep
ALTERNATE POSITION (143 mm high x 51 mm wide x 54 mm deep)
OF SENSING ELEMENT Bulb Size: 3/8 in. x 2 7/8 in. (10 mm x 73 mm) copper
CAPILLARY
Mounting: Horizontal or Vertical
Maximum Ambient Temperature: 150 F (66 C)
Electrical Ratings
Full Load: 8A @ 120 Vac; 5.1A @ 240 Vac
Locked Rotor: 48A @ 120 Vac; 30.6A @ 240 Vac
Millivolt: 0.25 A @ 0.25 to 12 Vdc
Approvals:
Canadian Standards Association: Certified: File No. LR95329-1
4-3/16
Underwriters Laboratories, Inc. UL Component Recognized: File No.
(106) MP466, Vol. 6, Sec.1, Guide No. MBPR2
MOUNTING
HOLE FOR
3/16 IN. (5 MM)
SCREW (3)
13/64
(5) (3)

15/16
(24)

3/8 (10) 1-1/4


(32)
ALTERNATE POSITION
SENSING
OF SENSING ELEMENT
ELEMENT
CAPILLARY M8823
CAPILLARY

Operating
Temperature Differential
Range Temperature Capillary
Length
Product Number Application (F) (C) (F) (C) (inch) Switching Action Includes
L4008A1015 High or Low limit 100 F to 38 C to 5 F to 30 F 3 C to 17 C 66 in. SPST, contacts break 5 1/2 ft (1.7 m) capillary
240 F 116 C adj. adj. on temperature rise.
L4008A1130 High or Low limit 130 F to 54 C to 5 F to 30 F 3 C to 17 C 120 in. SPST, contacts break Stop factory-set at 200 F (93 C);
270 F 132 C adj. adj. on temperature rise. 10 ft (3.04 m) capillary
L4008B1013 Circulator 100 F to 38 C to 5 F to 30 F 3 C to 17 C 66 in. SPST, contacts make 5 1/2 ft (1.7 m) capillary
240 F 116 C adj. adj. on temperature rise.
* L4008E1156 High Limit; 130 F to 54 C to Manual Manual 66 in. SPST, contacts break 5 1/2 ft (1.7 m) capillary;
Manual Reset 270 F 132 C Reset Reset on temperature rise. Stop factory-set at 250 F (121 C);
Heat-conductive compound
* L4008E1305 High Limit; 100 F to 38 C to Manual Manual 66 in. SPST, contacts break Stop factory-set at 240 F (116 C)
Manual Reset 240 F 116 C Reset Reset on temperature rise.
L4008E1313 High Limit; 100 F to 38 C to Manual Manual 66 in. SPST, contacts break —
Manual Reset 200 F 116 C Reset Reset on temperature rise.
* L6008A1192 Circulator 100 F to 38 C to 5 F to 30 F 3 C to 17 C — SPDT 66 in. capillary;
Control and Low 240 F 116 C adj. adj. Stop factory-set at 240 F (116 C)
Limit
L6008A1242 Circulator 100 F to 38 C to 5 F to 30 F 3 C to 17 C — SPDT 66 in. capillary
Control and Low 200 F 93 C adj. adj.
Limit
* TRADELINE models • SUPER TRADELINE models

188 customer.honeywell.com 70-6910


Aquastat Controllers
L4103 Combination Aquastat® and High Limit Controller

Controls
Home
The L4103A,B is an immersion-type controller for oil-fired water
heaters. The Aquastat® Controller senses water temperature and
cycles the burner through the oil primary. The high-limit controller
breaks the circuit to the burner on a temperature rise past the
factory-set setpoint. The L4103C is an immersion-type controller
for gas systems that provides water temperature regulation. The
high-limit controller breaks the circuit to the burner on a

Indoor Air Quality


temperature rise past the factory-set setpoint.
• L4103A,B,C have a sensing element and a high limit sensor with
automatic reset.
• Mounts on a horizontal immersion well in water heater wall.
• Adjustable temperature setting scale.
• Fluid-filled element operates SPST, Micro Switch™ snap-acting
switch.
• Integral, nonadjustable high limit. L4103C is an immersion controller
for gas systems.

Combustion Controls
• L4103A,B is an immersion controller for oil systems.

Residential
Dimensions in inches (millimeters)

KNOCKOUT FOR 1/2 INCH CONDUIT (6) WELL-CLAMP SCREW

3/4-14 NPT
1-3/16
(30)
1-13/64

Hydronic Controls
(31)
3-7/8
(99) INSULATION MAXIMUM INSERTION
DEPTH 3-3/8 OR 5 (86 OR 127)
1-13/64 2-1/4 OR 4
(31) (57 OR 102)

3/4
(19)
1-3/8
2-3/64 (52) (35)
1-13/16
4-3/32 (104) (46)
M6806A
2-11/16 (68)

Controls
Water
Case Dimensions: 4 3/32 in. wide x 3 7/8 in. high x 2 11/16 in. deep Electrical Ratings:
(104 mm wide x 99 mm high x 68 mm deep.) Full Load: 5A @ 240 Vac; 8A @ 120 Vac
Operating Temperature Range: 100 F to 240 F stop set at 150 F Locked Rotor: 30A @ 240 Vac; 48A @ 120 Vac
(Scale marked- Hot-Normal-Warm) (38 C to 116 C stop set at 66 C Approvals:
(Scale marked- Hot-Normal-Warm) Underwriters Laboratories, Inc. UL Component Recognized: File No.
MP466, Guide No. MBPR2.

Building Automation
Differential Well Spud
Temperature Size Insulation Depth
Product Number Application (F) (F) (inch) (mm) (inch) (mm) Switching Action Mounting
L4103A1019 High Limit 7F±4F 3.9 C ±2 C 3/4 in. 19 mm 4 in. 102 mm SPST, contacts break Mounts on a horizontal immersion
NPT NPT on temperature rise. well in water heater wall.
L4103A1100 High Limit 7F±4F 3.9 C ±2 C 3/4 in. 19 mm 2 1/4 in. 57 mm SPST, contacts break Mounts on a horizontal immersion
NPT NPT on temperature rise. well in water heater wall.

Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 189
Aquastat Controllers
L8100 Aquastat® Controller
L8100A,B, and C are immersion type controllers for regulating and
limiting the tank temperature in water heaters. As the water
temperature rises past the setpoint, the controller switches off the
gas valve.
• Regulates temperature and provides energy cutoff (ECO) action on
a temperature rise past the setpoint.
• Includes a second sensing element that senses average water
temperature to minimize stacking.
• Fluid-filled element operates Micro Switch™ SPST snap-acting
switch.
• ECO switch interrupts the thermocouple circuit or main valve before
tank reaches 210 F (99 C) maximum temperature.
• Includes factory-installed immersion well on controller.
• Internal adjustment screw.
• Special switch terminal provides three-wire hookup from Aquastat®
controller to gas valve.

Dimensions in inches (millimeters)


TANK WALL

1/2 OR 3/4 — 14 NPT

A B

CONTROLLER WELL REMOTE WELL


IN. MM IN. MM
A INSULATION DEPTH 2-1/4 57 1-1/2 OR 2-1/2 38 OR 64
B INSERTION DEPTH 5 127 3 76
C WELL DIAMETER 7/16 11 7/16 11

M4746

Bulb Size: 3/8 in. (10 mm)


Differential Temperature: Controller: 5 F, fixed. Energy Cutoff Switch:
20 F, fixed. (Controller: 3 C fixed; Energy Cutoff Switch: 11 C fixed.)
Temperature Rating (ECO) Energy Cutoff: 190 F
Maximum Ambient Temperature: Maximum Tank: 210 F (Maximum
Tank: 99 C)
Operating Temperature Range: 100 F to 180 F (38 C to 82 C)
Electrical Ratings:
Millivolt: 2A maximum at 24 Vac.
Approvals:
American Gas Association IAS: Design Certified: Report Number 23-
11B
Underwriters Laboratories, Inc. UL Component Recognized: File No.
MP466, Guide No. MBPR2

Capillary
Length Insulation Depth
Product Number Application (inch) (inch) (mm) Switching Action Mounting Includes
L8100B1037 High Limit 42 in. controller well: 2 1/4 in. controller well: 57 mm, SPST, contacts Immersion —
remote well: 1 1/2 or remote well: 38 mm or break on Well
2 1/2 in. 64 mm temperature rise.
L8100B1094 High Limit 54 in. controller well: 2 1/4 in. controller well: 57 mm, SPST, contacts Immersion Two zinc plated wells
remote well: 1 1/2 or remote well: 38 mm or break on Well and one well clamp for
2 1/2 in. 64 mm temperature rise. remote well.
L8100B1128 High Limit 39 in. 1 1/2 in. 38 mm SPST, contacts Immersion —
break on Well
temperature rise.

190 customer.honeywell.com 70-6910


Aquastat Controllers
L4081; L6081 Multiple Aquastat® Controllers

Controls
Home
High limit, low limit and/or circulator controllers used to regulate
boiler water temperature in gas- or oil-fired hydronic heating
systems.
• An immersion type liquid-filled sensing element actuates two snap
switches.
• One switch operates as a high limit control.
• The other switch operates as a low limit and/or circulator control,

Indoor Air Quality


depending on the model.
• Controller may be mounted in any positioning and needs no leveling.
• Separate, easy-to-read, calibrated dial and setpoint adjustments for
each switch.
• Differential adjustment on low limit or circulator switch.
• All adjustments accessible inside front cover.
• Push-in terminals for quick connecting.
• Single sensing element for easy installation.
Cover Controller • One SPST and one SPDT snap switches act independently at

Combustion Controls
respective temperature settings.

Residential
Maximum Ambient Temperature: 150 F at switches; 265 F at sensing Full Load: 5.1A @ 240 Vac; 8A @ 120 Vac
element (66 C at switches; 129 C at sensing element) Locked Rotor: 30.6A @ 240 Vac; 48A @ 120 Vac
Operating Range, High Limit: 130 F to 240 F (54 C to 116 C) Millivolt: 0.25 A @ 0.25 to 12 Vdc
Operating Range, Low Limit: 110 F to 220 F (43 C to 104 C) Approvals:
Operating Humidity Range (% RH): 0 to 95% RH, non-condensing Canadian Standards Association: Certified: File No. LR95329-1
Electrical Ratings Underwriters Laboratories, Inc. UL Listed: File No. MP466, Vol. 12,
Ignition: Transformer Load: 360 VA Sec. 4, Guide No. MBPR2

Hydronic Controls
Differential Well Spud
Temperature Insulation Depth Size
Switching
Product Number Application (F) (inch) (mm) (inch) Action Mounting Includes
L4081A1023 High and Low High limit: 10 F fixed; 1 1/2 in. 38 mm 3/4 in. - 14 NPT SPST: High & Horizontal —
limit low limit: 10-25 F adj. Low Limit
L4081B1013 High Limit and 10 F fixed 3 in. 76 mm 3/4 in. - 14 NPT SPST: High Limit Horizontal —
Circulator & Circulator
L4081B1047 High Limit and High limit: 10 F fixed; 1 1/2 in. 38 mm 3/4 in. - 14 NPT SPST: High Limit Horizontal —

Controls
Circulator low limit: 10-25 F adj. & Circulator

Water
L4081B1096 High Limit and 10 F fixed 3 in. 76 mm — SPST: High Limit Horizontal —
Circulator & Circulator
* L6081A1010 High and Low 10 F fixed 3 in. 76 mm 3/4 in. - 14 NPT — Horizontal 3 in. insertion well.
limit
* L6081A1036 High and Low High limit: 10 F fixed; 1 1/2 in. 38 mm 3/4 in. - 14 NPT — Horizontal —
limit low limit: 10-25 F adj. to 4 in.

Building Automation
* TRADELINE models • SUPER TRADELINE models
Dimensions in inches (millimeters)

Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 191
Aquastat Controllers
JUNCTION BOX
R4184D PROTECTORELAY™ CONTROL

SS
BLACK

1K2
ORANGE
1K BURNER MOTOR

CAD
CELL OIL VALVE
1K1
SOLID
F STATE
SWITCH
SAFETY IGNITION
SWITCH
HEATER

F WHITE

L1
L2 1 (HOT)

CIRCULATOR

B 2 B W
2 4 3 1
24V 1R1
THERMOSTAT
R R

T L6081A
JUMPER
1R ADDED
T 1 POWER SUPPLY. PROVIDE DISCONNECT
MEANS AND OVERLOAD PROTECTION
RA89A SWITCHING RELAY AS REQUIRED.

2 B TERMINALS ARE TAB TERMINALS.


M8855

192 customer.honeywell.com 70-6910


Aquastat Controllers
L8124 Triple Aquastat® Relay

Controls
Home
Immersion-type controllers that combine high limit protection with
low limit and circulator control in forced hydronic heating systems,
including domestic hot water service.
• Immersion-type controllers that combine high limit protection with
low limit and circulator control in forced hydronic heating systems.
• Provide multizone control by using a separate circulator and R845
Relay for each zone.

Indoor Air Quality


• Include diaphragm powerhead and Micro Switch™ assembly that
respond to temperature changes in boiler water.
• Mount directly to boiler.
• Select models include large transformers and extra terminals for
supplying power to low voltage zone valves.
• Require 24 Vac thermostat with heat anticipator set at 0.2 A (plus
current draw of gas valve on L8124E).
• TRADELINE models include tube of heat conductive compound and
range stops.

Combustion Controls
Vertical Vertical

Residential
Hydronic Controls
Horizontal

Voltage: 120 Vac


Maximum Ambient Temperature: 150 F at switches, 265 F at sensing Electrical Ratings
element. (66 C at switches, 129 C at sensing element.)
burner circulator
Operating Range, High Limit: 130 F to 240 F adj. (54 C to 116 C adj.)
Operating Range, Low Limit: 110 F to 220 F adj. (43 C to 104 C adj.) AFL ALR AFL ALR

Controls
Maximum Operating Pressure: 200 psi on outside of immersion well, L8124A 3.7 A @ 240 Vac; 22.2 A @ 240 Vac; 3.7 A @ 240 Vac; 22.2 A @ 240 Vac;

Water
100 psi on capsule if inserted directly. (1378 kPa on outside of 7.4 A @ 120 Vac 44.4 A @ 120 Vac 7.4 A @ 120 Vac 44.4 A @ 120 Vac
immersion well, 690 kPa on capsule if inserted directly.) L8124B, Line Voltage: Line Voltage: 3.7 A @ 240 Vac; 22.7 A @ 240 Vac;
Operating Humidity Range (% RH): 0 to 95% RH, non-condensing C, E, G, L 7.4 A @ 120 Vac; 44.4 A @ 120 Vac; 7.4 A @ 120 Vac 44.4 A @ 120 Vac
3.7 A @ 240 Vac 22.7 A @ 240 Vac
Approvals:
Canadian Standards Association: Certified: File No. LR1620, Guide
No. 400-E-O Replacement Parts:

Building Automation
Underwriters Laboratories, Inc. UL Listed (models with well): File No. L7224U1002 120 Vac Oil Electronic Aquastat® Controller with
MP466, Guide No. MBPR; UL Component Recognized (models Enviracom communication and troubleshooting Leds
without well): File No. MP466, Guide No. MBPR2

Differential
Temperature Insulation Depth
Switching
Product Number Application (F) (inch) (mm) Action Mounting Includes
L8124A1007 High Limit Protection, Low High limit: 10 F fixed; 1 1/2 in. 38 mm — Vertical Mount 3 in. insertion well.
Limit and Circulation Control low limit: 10-25 F adj.

Components
Commercial
L8124A1015 High Limit Protection, Low High limit: 10 F fixed; 3 in. 76 mm — Vertical Mount 3 in. insertion well
Limit and Circulation Control low limit: 10-25 F adj. and ground screw.
* L8124B1039 Triple Aquastat Relay with High limit: 10 F fixed; — — SPST: High & Vertical Mount —
High limit low limit: 10-25 F adj. Low Limit
L8124C1003 Triple Aquastat Relay with High limit: 10 F fixed; — — SPST: High & Horizontal —
High limit low limit: 10-25 F adj. Low Limit
L8124C1102 High Limit Protection, Low High limit: 10 F fixed; 1 1/2 in. to 3 38 mm to 76 — Horizontal —
Pneumatic Controls

Limit and Circulation Control low limit: 10-25 F adj. in. less well. mm less well
* L8124E1016 Triple Aquastat Relay with High limit: 10 F fixed; — — SPST: High & Vertical Mount —
High limit low limit: 10-25 F adj. Low Limit
L8124G1020 Triple Aquastat Relay with High limit: 10 F fixed; — — SPST: High & Vertical Mount —
High limit low limit: 10-25 F adj. Low Limit
L8124L1011 Triple Aquastat Relay with High limit: 10 F fixed; — — SPST: High & Horizontal —
High limit low limit: 10-25 F adj. Low Limit
Industrial Combustion

* TRADELINE models • SUPER TRADELINE models


Controls

70-6910 193
Aquastat Controllers
Dimensions in inches (millimeters)
ZONE 1 ZONE 2
THERMOSTAT THERMOSTAT

V8043F V8043F

TH TH
TH TR TH TR
TR TR

L8124G,L
3
G
TV T Z

1 L1
1K (HOT)

2 L2 1

1K1

W R B ZR
LOW LIMIT/
CIRCULATOR
ZC
LINE VOLTAGE
B OIL BURNER
1K2 HIGH RELAY OR
LIMIT 4 GAS VALVE

R B1

LOW VOLTAGE
THERMOSTAT B2
C2
L8124A,C
2
G
C1
T T 1 L1 LINE VOLTAGE
(HOT) CIRCULATOR

2 L2 1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND


1K 1 OVERLOAD PROTECTION AS REQUIRED.

2 UP TO TWO V8043F ZONE VALVES CAN BE POWERED WITH


L8124G,L. ADD ADDITIONAL TRANSFORMER FOR EVERY
W R B TWO OR LESS VALVES.
1K1
LOW LIMIT/
CIRCULATOR 3 CONTROL CASE MUST BE CONNECTED TO EARTH GROUND.
ZR
USE GROUNDING SCREW PROVIDED.

ZC 4 B1 IS 1/4 IN. TAB TERMINAL. M1795B

LINE VOLTAGE
B OIL BURNER
RELAY OR
HIGH
1K2 3 GAS VALVE
LIMIT
R B1

B2

C1

C2

LINE VOLTAGE
CIRCULATOR

1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND


OVERLOAD PROTECTION AS REQUIRED.

2 CONTROL CASE MUST BE CONNECTED TO EARTH GROUND.


USE GROUNDING SCREW PROVIDED.

3 B1 IS 1/4 IN. TAB TERMINAL. M8802

194 customer.honeywell.com 70-6910


Aquastat Controllers

Controls
Home
LOW VOLTAGE LOW VOLTAGE
THERMOSTAT THERMOSTAT
L8124B L8124E
2 2
G G
T T TV T Z

Indoor Air Quality


1 L1 1 L1
(HOT) (HOT)
1K
2 L2 2 L2
1 1
1K2
1K 1K3 1K2

W R B W R B
1K1 1K1
LOW LIMIT/ LOW LIMIT/
CIRCULATOR

Combustion Controls
CIRCULATOR
R LINE VOLTAGE R LINE VOLTAGE

Residential
HIGH CIRCULATOR HIGH CIRCULATOR
LIMIT C1 LIMIT C1

B B
C2 C2

3 3
B1 TH B1 TR

Hydronic Controls
B2 TH B2 TH

LOW VOLTAGE
PP GAS VALVE
1 POWER SUPPLY. PROVIDE (eg, VR8300)
DISCONNECT MEANS AND
OVERLOAD PROTECTION PP 1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND
AS REQUIRED. OVERLOAD PROTECTION AS REQUIRED.
POWERPILE® MILLIVOLTAGE
2 CONTROL CASE MUST BE GAS VALVE 2 CONTROL CASE MUST BE CONNECTED TO EARTH GROUND.
CONNECTED TO EARTH GROUND. USE GROUNDING SCREW PROVIDED.
USE GROUNDING SCREW PROVIDED.
M8803
3 B1 IS 1/4 IN. TAB TERMINAL.
3 B1 IS 1/4 IN. TAB TERMINAL. M8842

Controls
Water
Building Automation
Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 195
Aquastat Controllers
L8148 Aquastat® Relay
Immersion-type controllers that combine high limit protection with
switching relay control of burner and circulator motors.
• High limit opens burner circuit only.
• Include transformer and accessory terminals for adding a remote low
limit controller.
• Case available for horizontal or vertical mounting.
• Requires a 24 Vac thermostat with heat anticipator set at 0.2A.
• TRADELINE models include well adapter, tube of heat conductive
compound and range stops.

Dimensions in inches (millimeters) Anticipator Setting: 0.2 A


Voltage: 120 Vac
Frequency: 60 Hz
Electrical Connections: Quick-Connect/Screw
Maximum Ambient Temperature: 150 F with 1.2 A 24 V load; 77 F
with 1.4 A 24 V load (66 C with 1.2 A 24 V load; 25 C with 1.4 A 24 V
load)
Setpoint Temperature Range: 240 F (116 C)
Operating Range, High Limit: 120 F to 240 F (54 C to 116 C)
Maximum Operating Pressure: Immersion Well: 255 psi (Immersion
Well: 1757 kPa)
Operating Humidity Range (% RH): 0 to 95% RH, non-condensing
Approvals:
Canadian Standards Association: Certified: File No. LR1620, Guide
No. 400-E-O
Underwriters Laboratories, Inc. UL Listed: File No. MP466, Vol. 13,
Sec. 2, Guide No. MBPR2.

Electrical Ratings
(burner
(AFL) (burner AFL) (burner ALR) millivolt) (circulator AFL) (circulator ALR)
L8148A — — Line Voltage: Line Voltage: 0.25 A @ 1/4 to 3.7 A @ 240 Vac; 22.2 A @ 240 Vac;
7.4 A @ 120 Vac; 44.4 A @ 120 Vac; 12 Vdc 7.4 A @ 120 Vac 44.4 A @ 120 Vac
3.7 A @ 240 Vac 22.7 A @ 240 Vac
L8148E 0.25 A @ 0.25 to 22.2A @ 240 Vac; Low Voltage: Line Voltage: 0.25 A @ 1/4 to 3.7 A @ 240 Vac; 22.7 A @ 240 Vac;
12 Vdc 44.4A @ 120 Vac 0.8 A max. @ 24 Vac; 44.4 A @ 120 Vac; 12 Vdc 7.4 A @ 120 Vac 44.4 A @ 120 Vac
Line Voltage: 22.7 A @ 240 Vac
7.4 A @ 120 Vac;
3.7 A @ 240 Vac
L8148J — — 3.7 A @ 240 Vac; 22.2 A @ 240 Vac; 0.25 A @ 1/4 to 3.7 A @ 240 Vac; 22.2 A @ 240 Vac;
7.4 A @ 120 Vac 44.4 A @ 120 Vac 12 Vdc 7.4 A @ 120 Vac 44.4 A @ 120 Vac

Differential
Temperature Capillary Length Insulation Depth
Switching
Product Number Application (F) (inch) (mm) (inch) (mm) Action Mounting Includes
* L8148A1017 High Limit 8 F fixed 4 1/2 in. 114 mm 1 1/2 in. to 3 38 mm to 76 SPST: High Horizontal —
in. less well mm less well Limit &
Circulator
* L8148E1265 High Limit 15 F fixed 4 1/2 in. 114 mm 1 1/2 in. to 3 38 mm to 76 SPST: High Vertical Molex® plug for use with
in. less well mm less well Limit & Mount vent damper, includes heat-
Circulator conductive compound.
Molex® plug for use with
vent damper, includes heat-
conductive compound.
* TRADELINE models • SUPER TRADELINE models

196 customer.honeywell.com 70-6910


Aquastat Controllers

Controls
Differential

Home
Temperature Capillary Length Insulation Depth
Switching
Product Number Application (F) (inch) (mm) (inch) (mm) Action Mounting Includes
L8148E1299 High Limit 15 F fixed 4 1/2 in. 114 mm 1 1/2 in. to 3 38 mm to 76 SPST: High Vertical 50 VA transformer and heat
in. less well mm less well Limit & Mount conductive compound.
Circulator
* L8148J1009 Aquastat 8 F fixed 4 1/2 in. 114 mm 1 1/2 in. to 3 38 mm to 76 SPST: High Horizontal —

Indoor Air Quality


Relay in. less well. mm less well Limit & or Vertical
Circulator
* TRADELINE models • SUPER TRADELINE models

24 VAC
THERMOSTAT
D892/M892 4 197516A L8148E1265
CABLE

Combustion Controls
4 4
TV T

Residential
W

1K
Z
3 2

HIGH LIMIT
CONTROLLER
2
3 FUSE
R

Hydronic Controls
3 1K2
B

2 5

1 1 C1 C2

1K1
POLARIZED 4-PRONG 6-PRONG FEMALE MOLEX
MALE MOLEX PLUG AND RECEPTABLE IN L8148E B1 B2 L1 L2
4-PRONG FEMALE AND 5-PRONG MALE 5 CIRCULATOR
MATING PLUG ON CABLE MOLEX PLUG ON CABLE

Controls
Water
L1 1 L2
1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD (HOT)
PROTECTION AS REQUIRED. S8600

2 REMOVE PLUG-IN THAT JUMPERS PINS 2 AND 3 WHEN USING VENT


DAMPER.
24V GND

Building Automation
3 AFTER VENT DAMPER IS PLUGGED INTO L8148E1265, FUSE BLOWS 24V
WHEN THERMOSTAT FIRST CLOSES. AFTER FUSE BLOWS, L8148E1265
OPERATES ONLY WHEN VENT DAMPER IS CONNECTED.

4 SEE VENT DAMPER PRODUCT SPECIFICATIONS FOR INTERNAL


SCHEMATICS.
M2763C

5 B1 IS 1/4 IN. TAB TERMINAL.

Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 197
Aquastat Controllers
1 24V
24V THERMOSTAT
L1 L2 THERMOSTAT
HOT W
3 L8148J
R TV W T
G L1 L2 T T L8148A L6006 B
LOW LIMIT TP Z 2
3
R 2 CONTROLLER
3 HIGH
W LIMIT
B
HIGH MILLIVOLTAGE
B B POWERPILE® GAS VALVE
LIMIT R
L6006
LOW LIMIT R PP TH2 C1 C2
CONTROLLER
PP TH1 B1 B2 B3 L1 L2 G
4
5 1
C1 C2 B1 B2 CIRCULATOR
TR TH
TO LINE 4
VOLTAGE THTR L1 L2
OIL BURNER (HOT)
RELAY OR
LOW VOLTAGE
GAS VALVE
G GAS VALVE
G
(eg, VR8300)
CIRCULATOR
1K1
L1
L1 B R
JUMPER 1K3 1K1
T T 3 TP B R
1
AUTO
1K 1K2 Z W T MANUAL
1K2
SWITCH
TV C1
C1
4
B3 B2 B1 C2
L2 C2 B2 B1 5
L8148A
L2
L8148J
1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD
PROTECTION AS REQUIRED. 1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND
OVERLOAD PROTECTION AS REQUIRED.
2 REMOVE JUMPER WHEN ADDING L6006 LOW LIMIT CONTROLLER.
2 REMOVE Z-W JUMPER IF SERIES 60 LOW LIMIT IS USED. WIRE
3 CONTROL CASE MUST BE CONNECTED TO EARTH GROUND. LOW LIMIT CONTROLLER OR ZONE VALVES AS SHOWN. USE
USE GROUNDING SCREW PROVIDED. WITH 24V (B1-B3) CIRCUIT ONLY.
M2842A
4 B1 IS 1/4 IN. TAB TERMINAL. 3 FOR 24V BURNER, WIRE B1-B3 AND USE JUMPER Z-W AND TP-Z.
FOR POWERPILE® (MILLIVOLTAGE) GAS VALVES, REMOVE
JUMPER TP-Z AND WIRE BURNER B1-B2. JUMPER Z-W
REMAINS IN POSITION.

4 CONTROL CASE MUST BE CONNECTED TO EARTH GROUND.


USE GROUNDING SCREW PROVIDED.

5 B1 IS 1/4 IN. TAB TERMINAL. M1793B

198 customer.honeywell.com 70-6910


Aquastat Controllers
L7224U Oil Electronic Aquastat® Controller

Controls
Home
The L7224U Oil Electronic Aquastat® Controller provides
electronic temperature sensing in a UL limit-rated controller with a
single sensing probe. The L7224U controls the circulator, oil
burner and boiler temperature. The L7224U replaces the L8124A,
L8124C, L7124U, L7148A, L7248A,C, L7224A,C, and L8148A
Controllers. The Aquastat Controller is intended for use in
residential-type applications. The L7224U provides status and

Indoor Air Quality


diagnostic information through an LED display combined with LED
lights to enhance the diagnostic process.
The L7224U is “Outdoor Temperature Reset” ready, which is
enabled when connected to the 50022037-002 Outdoor Reset
Module and C7089U Outdoor Temperature Sensor. The L7224U
can also interface with the 50022037-005 Domestic Hot Water
Module for prioritization of a domestic hot water call for heat. Ideal
for indirect tank applications.

Combustion Controls
Residential
Dimensions, Approximate: 7 1/8 in. high x 4 1/4 in. wide x 2 5/8 in. Operating Humidity Range (% RH): 0 to 95% RH, non-condensing
deep (181 mm high x 109 mm wide x 67 mm deep)
Electrical Ratings
Maximum Power Consumption: 2000 VA (burner AFL): 7.4 A @ 120 Vac
Voltage: 120 Vac (burner ALR): 44.4 A inrush
Frequency: 60 Hz (circulator AFL): 7.4 A @ 120 Vac
Maximum Ambient Temperature: 150 F (66 C) (circulator ALR): 44.4 A inrush

Hydronic Controls
Minimum Ambient Temperature: -30 F (-9 C)
Approvals:
Operating Range, High Limit: 130 F to 240 F (54 C to 116 C)
Underwriters Laboratories, Inc. Recognized
Operating Range, Low Limit: 110 F to 220 F (43 C to 104 C)

Differential
Temperature
Product Number Application (F) Mounting Includes
L7224R1000 Oil Aquastat Controller with High limit: 5-20 F adj.; low Well mount, horizontal or vertical position, or flush W8735S1000
Outdoor Reset Module limit: 10-25 F adj. mounted remote from the well.
L7224U1002 Oil Aquastat Controller High limit: 5-20 F adj.; low Well mount, horizontal or vertical position, or flush —

Controls
Water
limit: 10-25 F adj. mounted remote from the well.

Building Automation
Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 199
Aquastat Controllers
R8182 Combination Protectorelay® and
Hydronic Heating Controllers
Immersion type Aquastat controller and oil burner primary control
provides high limit and low limit/circulator control for oil-fired
hydronic heating systems.
• Use in intermittent ignition applications.
• Capable of zone control with zone valves.
• Circulator zone control with ZC and ZR terminals on R8182D,E,H,J.
8*Flame failure during the running cycle results in a 45 second
attempt to restart.
• If unsuccessful, safety shutoff occurs, requiring manual reset before
burner can be restarted.
• R8182D,E,F mount directly on burner; R8182H,J mount on 4 x 4 in.
junction box and include 5 ft (1.5 m) armored capillary with remote
sensor.
• C554A Cadmium Sulfide Flame Detector and a 24 Vac thermostat
required.

Junction Box Mount

Dimensions in inches (millimeters)

Anticipator Setting: 0.2 A Operating Humidity Range (% RH): 0 to 95% RH, non-condensing
Maximum Power Consumption: 9 W
Electrical Ratings
Voltage: 120 Vac (ignition): 360 VA
Frequency: 60 Hz (burner AFL): 4.4 A @ 120 Vac
Timing Safety Switch: 45 sec (burner ALR): 26.4 A inrush
Maximum Ambient Temperature: 250 F at element (121 C at element)
Operating Range, High Limit: 130 F to 240 F (54 C to 116 C) Approvals:
Operating Range, Low Limit: 110 F to 220 F (43 C to 104 C) Canadian Standards Association: Certified: File No. LR95329-1
Maximum Operating Pressure: 200 psi on immersion well; 100 psi Underwriters Laboratories, Inc. UL Listed: File No. listed: MP268, Vol.
direct immersion. (1378 kPa on immersion well; 90 kPa direct 3,4 (R8182D,E,F), Vol. 37 (R8182H,J), Sec. 1.
immersion.)

200 customer.honeywell.com 70-6910


Aquastat Controllers

Controls
Home
Differential Insulation
Temperature Depth
Product Number (F) (inch) (mm) Mounting Includes
* R8182D1079 High limit: 10 F fixed; 1 1/2 in. 38 mm Vertical Mount Auxiliary ZC and ZR terminals may be used to provide circulator zone
Low limit/circulator: 10 control through an R845A Switching Relay. Heat-conductive compound
F to 25 F adj. and vertical case.

Indoor Air Quality


* R8182D1111 High limit: 10 F fixed; 1 1/2 in. 38 mm Horizontal Auxiliary ZC and ZR terminals may be used to provide circulator zone
Low limit/circulator: 10 control through an R845A Switching Relay. Heat-conductive compound
F to 25 F adj. and vertical case.
* R8182H1070 High limit: 10 F fixed; 1 1/2 in. 38 mm Junction box Auxiliary ZC and ZR terminals may be used to provide circulator zone
Low limit/circulator: 10 mount control through an R845A Switching Relay. Heat-conductive compound
F to 25 F adj. and horizontal case.
* TRADELINE models • SUPER TRADELINE models

Combustion Controls
Outdoor Reset

Residential
The AquaReset™ Outdoor Reset Module, when connected to the
C7089U Outdoor Sensor, works with any AquaReset enabled
Aquastat® such as the L7224/48 via the EnviraCOM™ 3-wire bus to
optimize boiler efficiency. The Outdoor Reset Module enables
efficiency Aquastat functionality, such as Outdoor Temperature
Reset, a Boost function, and a Warm Weather Shutdown function
to generate average operational savings of up to 15%.

Hydronic Controls
• Enables Boiler Outdoor Temperature Reset
• Enables Warm Weather Shutdown
• Enables Boost Override
• Easy push wire terminals that provide a secure lock with no need to
screw in wires.
• Simple low-voltage, 5-wire installation (3 EnviraCOM, 2 temperature
sensor)
• EnviraCOM™ Enabled

Dimensions, Approximate: Maximum Ambient Temperature: 150 F (66 C)


2.410 in. high x 3.385 in. wide x .920 in deep Minimum Ambient Temperature: -30 F (-9 C)

Controls
Electrical Ratings: 24 Vac, 60 Hz Operating Humidity Range (% RH): 0 to 95% RH, non-condensing

Water
Product Number Mounting Includes
W8735S1000 Wall Mounted in any orientation C7089U1006 Outdoor Sensor, Outdoor Reset Module
W8735S1008 Wall Mounted in any orientation Water Pipe Temperature Sensor, Domestic Hot Water Module

Building Automation
Single and Multi-function Aquastat® Parts
Bulb Lead
Diameter Length Leadwire Leadwire
Product Number Type Description (inch) (inch) Ending Temperature Used With
120650 — Heat Conductive Grease 1/2 oz. — — — — Well
Assembly
198799Z Sensor Outdoor or Supply sensor with 42 in. lead for 3/8 in. 42 in. Strip & Retain 125 C —

Components
Commercial
AQ475, AQ675 or AQ775
32004955-005 Sensor Sensor Assembly for use with L71XX series of — 48 in. — — —
Electronic Aquastats

Pneumatic Controls
Industrial Combustion
Controls

70-6910 201
Well Assemblies
Well Assemblies
Shell Spud
Insertion (internal Thread
Product Number Description Materials Length diameter) Size Includes
121371A Copper. Bulb size: 3/8 in. x Copper 1 1/2 in. 3/8 in. 1/2 in. x 121371 Mounting
3 in. (10 mm x 76 mm). 14 NPT Clamp
Well size:3 in. (76 mm)
insertion, 1 1/2 in. NPT.
Includes mounting clamp.
121371AA Well clamp assembly with — — — — 121371 Mounting
clamp capillary 21371 (1) Clamp, Spud Set
screws 804644 and nuts screw for armored
60156 capillary, Plug, and
Nut.
121371B Copper. Bulb size: 3/8 in. x Copper 1 1/2 in. 3/8 in. 3/4 in. x 121371 Mounting
3 in. (10 mm x 76 mm). 14 NPT Clamp
Well size:3 in. (76 mm)
insertion, 1 1/2 in. (38 mm)
insulation, 3/4 in. NPT.
Includes mounting clamp.
121371E Stainless steel. Bulb size: Stainless 1 1/2 in. 3/8 in. 1/2 in. x 121371 Mounting
3/8 in. x 3 in. (10 mm x 76 Steel 14 NPT Clamp
mm). Well size:3 in. (76
mm) insertion, 1 1/2 in.
(38 mm) insulation, 1/2 in.
(13 mm) NPT. Includes
mounting clamp.
121371L Copper. Bulb size: 3/8 in. x Copper 3 in. 3/8 in. 1/2 in. x 121371 Mounting
3 in. (10 mm x 76 mm). 14 NPT Clamp
Well size:3 in. (76 mm)
insertion, 3 in. (76 mm)
insulation, 1/2 in. NPT.
Includes mounting clamp.
121371M Copper. Bulb size: 3/8 in. x Copper 3 in. 3/8 in. 3/4 in. x 121371 Mounting
3 in. (10 mm x 76 mm). 14 NPT Clamp
Well size:3 in. (76 mm)
insertion, 1 1/2 in. (38 mm)
insulation, 3/4 in. NPT.
Includes mounting clamp.
123869A Copper. Bulb size: 3/8 in. x Copper 1 1/2 in. 3/8 in. 1/2 in. x 125975 Well Clamp
3 in. (10 mm x 76 mm). 14 NPT
Well size: 3 in. (76 mm)
insertion, 1 1/2 in. (38 mm)
insulation, 1/2 in. NPT.
123870A Copper. Bulb size: 3/8 in. x Copper 1 1/2 in. 3/8 in. 3/4 in. x —
3 in. (10 mm x 76 mm). 14 NPT
Well size: 3 in. (76 mm)
insertion, 1 1/2 in. (38 mm)
insulation, 3/4 in. NPT.
123871A Copper. Bulb size: 3/8 in. x Copper 3 in. 3/8 in. 3/4 in. x —
3 in. (10 mm x 76 mm). 14 NPT
Well size: 3 in. (76 mm)
insertion, 3 in. (76 mm)
insulation, 3/4 in. NPT.
123872A Copper. Bulb size: 3/8 in. x Copper 3 in. 3/8 in. 1/2 in. —
3 in. (10 mm x 76 mm). NPT
Well size: 3 in. (76 mm)
insertion, 3 in. (76 mm)
insulation, 1/2 in. NPT
124299AA Copper. Bulb size: 3/8 in. Copper 1 1/2 in. 3/8 in. 3/4 in. x Set screw in spud
(10 mm). Well size: 3 in. 14 NPT for armored capillary
(76 mm) insertion, 1 1/2 in. with plug
(38 mm) insulation, 3/4 in.
NPT. Includes set screw
with spud for armored
capillary with plug.
138134B/0021 Bulb size: 3/8 in. x 3 in. Zinc plated 4 1/2 in. — 3/4 in. x —
(10 mm x 76 mm). Well 14 NPT
size: 3 in. (76 mm)
insertion, 3/4 in. NPT

202 customer.honeywell.com 70-6910


AQUATROL Zoning System
AQ250 Electronic Relay Boiler Control Panel for

Controls
Home
Hydronic Zoning System
The AQ250 family of AQUATROL Boiler Controls provides
simplified, energy-efficient control of single temperature,
residential hydronic heating systems. The AQ250 easily converts a
single zone heating system into a room-by-room comfort control
system, or upgrades a basic, relay-logic zoning system to

Indoor Air Quality


intelligent Zone of Greatest Demand control for increased energy
efficiency with reduced boiler cycling. AQ250 boiler controls can
ensure ample supply of hot water for both space heating and
priority generation of domestic hot water for bathing, dishes and
laundry.
• Controls up to 2 stages of heat from a single thermostat.
• Use with AQ1000 2-wire communicating thermostats, or most dry
contact digital thermostats.
• Zoning Control for up to 4 zones as shipped; can be expanded to a

Combustion Controls
total of 16 zones with AQ255 or AQ257 expansion zoning panels
and up to 64 zones when used with AQ254 Add-A-Temp panels.

Residential
• Line or low-voltage output for zoning equipment (pumps or valves).
• Zone synchronization through Zone or Greatest Demand control.
• Domestic hot water priority and priority override protection.
• Boiler short cycling protection.
• Boiler post purge.
• Freeze protection.
• Pump/valve exercise.
• Boiler shock prevention from cold water returning to boiler.

Hydronic Controls
• Automated test feature for quick start-up and simplified
troubleshooting.
• Integral 38 VA transformer with self-resetting electronic fuse.
Application: Boiler control for zoned hydronic systems Auxiliary Pump Output Rating: Dry contact output, 120 Vac/250 Vac
Dimensions, Approximate: 13 in wide x 8 in. high x 3 3/8 in deep 5A, 1/3 HP
(33 cm wide x 20.3 cm high x 8.5 cm deep) Zone Output Contact Rating: Pumps: 120 Vac/250 Vac, 5A, 1/3 HP
Power Supply: 120V/60Hz Valves: 24 Vac, 0.5 A, 12 VA
User Interface (Setting, Programming): (DIP Switches) ZR-ZC Contact Rating: 120 to 240 Vac, 1/3 HP
Electrical Connections (Line Voltage): Wire-clamp screw terminals, Sensor Temperature Rating: -58 F to +230 F (-50 C to +110 C)
Maximum 2 x 14 AWG each on line voltage terminals Supply/Return Sensor: Lead Length: 10 ft. (3050 mm). 10 kilohm NTC

Controls
Control and Zoning Panel Temperature Rating: 32 F to 130 F (0 C to thermistor at 25 C (77 F) ±0.5F (±0.3C) up to 500 ft (150 M) using 18

Water
55 C) AWG or larger wire
Thermostat Compatibility: AQ1000 Series 2-wire communicating Heat Demand (Thermostat R-W) Input: External dry contacts
thermostats and most digital thermostats connection only
Zone Module Thermostat input: Low voltage, Class II, 2-wire polarity- B-B Communication Bus Terminals: Low voltage, Class II, 2-wire
insensitive, digital communicating with power link to AQ1000 series polarity-insensitive, digital communicating link to other Control or
thermostat. Zoning modules.

Building Automation
Boiler Heat Post Purge: 30 seconds (sent to DHW tank or Zone of R-C Input (on Control and Zoning Modules): 24 Vac Class II
Greatest Demand - selectable) R-C Output (on transformer): 38 VA, 24 Vac Class II
Boiler (T-T) Output Rating: 24 Vac, 0.5A, 12VA Operating Humidity Range (% RH): 5 to 90% RH, non-condensing
DHW Demand Input: External dry contacts connection only Weight: 4.9 lbs (2.3 kg)
Pump/Valve exercise: 30 seconds per 2 weeks of space heating
Approvals:
inactivity Canadian Standards Association: CSA C/US Certified to CSA and
UL Standards, File No. LR76030

Number of DHW Pump/


Type of Zoning Zones Boiler Pump Valve Output
Product Number Devices Controlled Controlled Output Rating Rating Replacement Parts

Components
Commercial
AQ25042B Zone pumps or 2-wire 4 120 Vac/250 Vac 120 Vac/250 Vac AQ15000B boiler control module
valves (line voltage) 5A, 1/3HP 5A, 1/3HP AQ12C11 supply/return/mixed loop sensor
AQ10X38 24 Vac 38 VA transformer
AQ15540B 4-zone pump expansion module
AQ25044B Zone valves with end 4 120 Vac/250 Vac 120 Vac/250 Vac AQ15000B boiler control module
switches 5A, 1/3HP 5A, 1/3HP AQ15740B 4-zone valve with end switch expansion module
AQ12C11 supply/return/mixed loop sensor
Pneumatic Controls

AQ10X38 24 Vac 38 VA transformer


Industrial Combustion
Controls

70-6910 203
AQUATROL Zoning System
AQ25A Programmable Relay Control Panel for
Hydronic Zoning System
• Displays outdoor temperature on all AQ1000 Series thermostats
when used with an AQ12C10 outdoor sensor (included).
• Intuitive programming interface and armchair programming (can be
programmed at your desk and taken to the job site "ready-to-install").
• Customizable control settings and schedules allow for greater level
of control and comfort.
• Controls up to 2 stages of heat from a single thermostat.
• Central programming of zone set points and setbacks
• Zoning Control for up to 4 zones as shipped; can be expanded to a
total of 16 zones with AQ255 or AQ257 expansion zoning panels,
and up to 64 zones when used with AQ254 Add-a-Temperature
panels.
• Zone synchronization through Zone of Greatest Demand control.
The AQ25A family of AQUATROL Programmable Relay Boiler • Domestic hot water priority and priority override protection.
Controls provides simplified, energy-efficient control of single- • Line or low-voltage output for zoning equipment (pumps or valves).
temperature, residential hydronic heating systems. The AQ25A • Boiler short cycling protection.
easily converts a single zone heating system into a room-by-room • Boiler post purge.
comfort control system, or upgrades a basic, relay-logic zoning • Freeze protection.
system to intelligent Zone of Greatest Demand control for in- • Pump/valve exercise.
creased energy efficiency with reduced boiler cycling. AQ25A • Boiler shock prevention from cold water returning to boiler.
boiler controls can ensure ample supply of hot water for both • Automated test and purge feature for quick start-up and simplified
space heating and priority generation of domestic hot water for troubleshooting.
bathing, dishes and laundry. • Integral 38 VA transformer with self resetting electronic fuse.
• Use with AQ1000 2-wire dry contact communicating thermostats and • 2 hour power supply (super-capacitor) to retain day and time settings
most digital thermostats. during power outage.
• 0-10 Vdc modulating output for driving a modulating/condensing • Non-volatile EPROM memory retains program settings during power
boiler. outage.

Application: Boiler control for zoned hydronic systems Auxiliary Pump Output Rating: Dry contact output, 120 Vac/250 Vac
Dimensions, Approximate: 16 1/2 in wide x 8 in. high x 3 3/8 in deep 5A, 1/3 HP
(42 cm wide x 20.3 cm high x 8.5 cm deep) Auxiliary Low Voltage Output Rating: 24 Vac, 0.5A, 12VA
Power Supply: 120V/60Hz Auxiliary (Demand) Input: External dry contacts connection only
User Interface (Setting, Programming): (LCD Display and a 7 button Zone Output Contact Rating: Pumps: 120 Vac/250 Vac, 5A, 1/3 HP
Key Pad) (DIP Switches on zoning modules) Valves: 24 Vac, 0.5 A, 12 VA
Electrical Connections (Line Voltage): Wire-clamp screw terminals, Sensor Temperature Rating: -58 F to +230 F (-50 C to +110 C)
Maximum 2 x 14 AWG each on line voltage terminals Supply/Return Sensor: Lead Length: 10 ft. (3050 mm). 10 kilohm NTC
Control and Zoning Panel Temperature Rating: 32 F to 130 F (0 C to thermistor at 25 C (77 F) ±0.5F (±0.3C) up to 500 ft (150 M) using 18
55 C) AWG or larger wire
Thermostat Compatibility: AQ1000 Series 2-wire communicating Heat Demand (Thermostat R-W) Input: External dry contacts
thermostats and most digital thermostats connection only
Zone Module Thermostat input: Low voltage, Class II, 2-wire polarity- B-B Communication Bus Terminals: Low voltage, Class II, 2-wire
insensitive, digital communicating with power link to AQ1000 series polarity-insensitive, digital communicating link to other Control or
thermostat. Zoning modules.
Setback Program: 7 day, up to 2 setback periods/day. R-C Input (on Control and Zoning Modules): 24 Vac Class II (input
Boiler Heat Post Purge: Off, 10 seconds to 30 minutes (factory default on Control and Zoning Modules)
is 30 seconds) R-C Output (on transformer): 38 VA, 24 Vac Class II
Boiler (T-T) Output Rating: 24 Vac, 0.5A, 12VA Operating Humidity Range (% RH): 5 to 90% RH, non-condensing
Boiler Differential: 2F to 41F (1C to 23C), or Auto (minimum 2 minutes Weight: 5.7 lbs (2.6 kg)
on time) Approvals:
DHW Demand Input: External dry contacts connection only Canadian Standards Association: CSA C/US Certified to CSA and
Pump/Valve exercise: 30 seconds per 2 weeks of space heating UL Standards, File No. LR76030
inactivity

Type of Zoning Number of DHW Pump/


Devices Zones Boiler Pump Valve Output
Product Number Controlled Controlled Output Rating Rating Replacement Parts
AQ25A42B Zone pumps or 4 120 Vac/250 Vac 120 Vac/250 Vac AQ15A00B boiler control module
2-wire valves 5A, 1/3HP 5A, 1/3HP AQ12C11 supply/return/mixed loop sensor
(line voltage) AQ12C10 outdoor sensor
AQ10X38 24 Vac 38 VA transformer
AQ15540B 4-zone pump expansion module
AQ25A44B Zone valves with 4 120 Vac/250 Vac 120 Vac/250 Vac AQ15A00B boiler control module
end switches 5A, 1/3HP 5A, 1/3HP AQ15740B 4-zone valve with end switch expansion module
AQ12C11 supply/return/mixed loop sensor
AQ12C10 outdoor sensor
AQ10X38 24 Vac 38 VA transformer

204 customer.honeywell.com 70-6910


AQUATROL Zoning System
AQ251 Electronic Boiler Reset Control Panel for

Controls
Home
Hydronic Zoning System
• Use with AQ1000 2-wire communicating thermostats (AQ25142B
and AQ25144B) or most digital dry contact thermostats (AQ25110B,
AQ25142B, and AQ25144B).
• 0-10 Vdc modulating output for driving a modulating/condensing
boiler.

Indoor Air Quality


• Displays outdoor temperature on all AQ1000 thermostats when used
with an AQ12C10 outdoor sensor (included).
• Intuitive programming interface and armchair programming (can be
programmed at your desk and taken to the job site "ready-to-install")
• Customizable control settings and schedules allow for greater level
of control and comfort.
• Central programming of zone set points and setback.
• Controls up to 2 stages of heat from a single thermostat.
• Zoning Control for up to four zones as shipped; can be expanded to

Combustion Controls
a total of 16 zones with AQ255 or AQ257 expansion zoning panels,
and up to 64 zones by using AQ254 Add-a-Temperature expansion

Residential
panels.
• Outdoor temperature compensation (reset), or Load reset based on
indoor temperature feedback.
• Zone synchronization through Zone of Greatest Demand control.
• Domestic hot water priority and priority override protection.
• Line or low-voltage output for zoning equipment (pumps or valves).
• Boiler short cycling protection.
The AQ251 family of AQUATROL Boiler Reset Controls provides • Boiler post purge.

Hydronic Controls
simplified, energy-efficient outdoor temperature compensated • Freeze protection.
control of single temperature, residential hydronic heating • Pump/valve exercise.
systems. The AQ251 easily converts a single zone heating system • Boiler shock prevention from cold water returning to boiler.
into a room-by-room comfort control system, or upgrades a basic, • Automated test and purge feature for quick start-up and simplified
relay-logic zoning system to intelligent Zone of Greatest Demand troubleshooting.
control with outdoor reset for in-creased energy efficiency with • Integral 38 VA transformer with self resetting electronic fuse.
reduced boiler cycling. AQ251 boiler controls can ensure ample • 2 hour power supply (super-capacitor) to retain day and time settings
supply of hot water for both space heating and priority generation during power outage.
of domestic hot water for bathing, dishes and laundry. • Non-volatile EPROM memory retains program settings during power
outage.
Application: Boiler reset control for hydronic zoning system Return Minimum Control Temperature: 80 F to 180 F (27C to 82C)

Controls
Water
Dimensions, Approximate Pump/Valve exercise: 30 seconds per 2 weeks of space heating
AQ25110B: 13 in wide x 8 in. high x 3 3/8 in deep inactivity
(33 cm wide x 20.3 cm high x 8.5 cm deep) Auxiliary Pump Output Rating: Dry contact output, 120 Vac/250 Vac
AQ25142B and AQ25144B: 16 1/2 in wide x 8 in. high x 3 3/8 in deep 5A, 1/3 HP
(42 cm wide x 20.3 cm high x 8.5 cm deep) Auxiliary Low Voltage Output Rating: 24 Vac, 0.5A, 12VA
Power Supply: 120V/60Hz Auxiliary (Demand) Input: External dry contacts connection only
User Interface (Setting, Programming): (LCD Display and a 7 button WWSD (Warm Weather Shut Down) Temperature: Off, 35 F to 100 F

Building Automation
Key Pad) (Off, 1 C to 38 C)
Electrical Connections (Line Voltage): Wire-clamp screw terminals, Sensor Temperature Rating: -58 F to +230 F (-50 C to +110 C)
Maximum 2 x 14 AWG each on line voltage terminals Supply/Return Sensor: Lead Length: 10 ft. (3050 mm). 10 kilohm NTC
Control and Zoning Panel Temperature Rating: 32 F to 130 F (0 C to thermistor at 25 C (77 F) ±0.5F (±0.3C) up to 500 ft (150 M) using 18
55 C) AWG or larger wire
Thermostat Compatibility: AQ1000 Series 2-wire communicating Heat Demand (Thermostat R-W) Input: External dry contacts
thermostats and most digital thermostats connection only
Setback Program: 7 day, up to 2 setback periods/day. B-B Communication Bus Terminals: Low voltage, Class II, 2-wire
Boiler Design Temperature: 80F to 210F (26C to 99C) polarity-insensitive, digital communicating link to other Control or
Boiler (Supply) Min. Control Temperature: OFF, 59F to 180F (OFF, Zoning modules.

Components
15C to 82C) R-C Input (on Control and Zoning Modules): 24 Vac Class II (input

Commercial
Boiler (Supply) Max. Control Temperature: (OFF, 120F to 225 F) on Control and Zoning Modules)
OFF, 49C to 107 C R-C Output (on transformer): 38 VA, 24 Vac Class II
Boiler Heat Post Purge: Off, 10 seconds to 30 minutes (factory default Operating Humidity Range (% RH): 5 to 90% RH, non-condensing
is 30 seconds) Weight
Boiler (T-T) Output Rating: 24 Vac, 0.5A, 12VA AQ25110B: 4.9 lbs (2.3 kg)
Boiler Differential: 2F to 41F (1C to 23C), or Auto (minimum 2 minutes AQ25142B and AQ25144B: 5.7 lbs (2.6 kg)
on time) Approvals:
Pneumatic Controls

DHW Demand Input: External dry contacts connection only Canadian Standards Association: CSA C/US Certified to CSA and
Outdoor Low Design Control Temperature: -60F to 32F UL Standards, File No. LR76030
(-51 C to 0 C)
Industrial Combustion
Controls

70-6910 205
AQUATROL Zoning System
Type of Zoning Number of
Devices Zones Boiler Pump DHW Pump/Valve
Product Number Controlled Controlled Output Rating Output Rating Replacement Parts
AQ25110B None 1 (Non- 120 Vac/250 120 Vac/250 Vac AQ15100B boiler reset module
communicating) Vac 5A, 1/3HP 5A, 1/3HP AQ12C11 supply/return/mixed loop sensor
AQ12C10 outdoor sensor
AQ10X38 24 Vac 38 VA transformer
AQ25142B Pumps or 2-wire 4 120 Vac/250 120 Vac/250 Vac AQ15100B boiler reset module
valves Vac 5A, 1/3HP 5A, 1/3HP AQ12C11 supply/return/mixed loop sensor
AQ12C10 outdoor sensor
AQ10X38 24 Vac 38 VA transformer
AQ15540B 4-zone pump expansion module
AQ25144B Zone valves with 4 120 Vac/250 120 Vac/250 Vac AQ15100B boiler reset module
end switches Vac 5A, 1/3HP 5A, 1/3HP AQ15740B 4-zone valve with end switch expansion
module
AQ12C11 supply/return/mixed loop sensor
AQ12C10 outdoor sensor
AQ10X38 24 Vac 38 VA transformer

206 customer.honeywell.com 70-6910


AQUATROL Zoning System
AQ252 Universal Injection/Mixing Boiler Reset Control Panel for

Controls
Home
Hydronic Zoning System
• Use with AQ1000 2-wire communicating thermostats or most digital
dry contact thermostats.
• Controls one boiler loop and one mixed temperature loop.
• Use of variable speed injection pump or motorized mixing valve for
mixed temperature loop control.

Indoor Air Quality


• 0-10 Vdc modulating output for driving a modulating/condensing
boiler or a modulating mixing valve.
• Displays of outdoor temperature on all AQ1000 thermostats when
used with an AQ12C10 outdoor sensor (included).
• Intuitive programming interface and armchair programming (can be
programmed at your desk and taken to the job site "ready-to-install")
• Customizable control settings and schedules allow for greater level
of control and comfort.
• Central programming of set points and setback.

Combustion Controls
• Controls up to 2 stages of heat from a single thermostat.
• Zoning Control for up to four zones as shipped; can be expanded to

Residential
a total of 16 zones with AQ255 or AQ257 expansion zoning panels,
and up to 64 zones by using AQ254 Add-a-Temperature expansion
panels.
• Outdoor temperature compensation (reset), or Load reset based on
indoor temperature feedback.
• Zone synchronization through Zone of Greatest Demand control.
• Domestic hot water priority and priority override protection.
• Line or low-voltage output for zoning equipment (pumps or valves).

Hydronic Controls
• Boiler short cycling protection.
The AQ252 family of AQUATROL Universal Injection/Mixing Boiler • Boiler post purge.
Reset Controls provides simplified, energy-efficient outdoor • Freeze protection.
temperature compensated control of single-temperature, • Pump/valve exercise.
residential hydronic heating systems. The AQ252 easily converts a • Boiler shock prevention from cold water returning to boiler.
single zone heating system into a room-by-room comfort control • Automated test and purge feature for quick start-up and simplified
system, or upgrades a basic, relay-logic zoning system to troubleshooting.
intelligent Zone of Greatest Demand control with outdoor reset for • Integral 38 VA transformer with self resetting electronic fuse.
increased energy efficiency with reduced boiler cycling. AQ252 • 4 hours power supply (super capacitor) to retain day and time
boiler controls can ensure ample supply of hot water for both settings during power outage.
space heating and priority generation of domestic hot water for • Non-volatile EPROM memory retains program settings during power
bathing, dishes and laundry. outage.

Controls
Water
Application: Controls one boiler and one mixing (either variable speed Secondary Pump Output Rating: 120 Vac 5A, 1/3HP
injection or floating valve mixing) loop in a hydronic zoning system. Auxiliary Pump Output Rating: Dry contact output, 120 Vac/250 Vac
Dimensions, Approximate: 16 1/2 in wide x 8 in. high x 3 3/8 in deep 5A, 1/3 HP
(42 cm wide x 20.3 cm high x 8.5 cm deep) Auxiliary Low Voltage Output Rating: 24 Vac, 0.5A, 12VA
Power Supply: 120V/60Hz Auxiliary (Demand) Input: External dry contacts connection only
User Interface (Setting, Programming): (LCD Display and a 7 button WWSD (Warm Weather Shut Down) Temperature: Off, 35 F to 100 F

Building Automation
Key Pad) (Off, 1 C to 38 C)
Electrical Connections (Line Voltage): Wire-clamp screw terminals, Zone Output Contact Rating: Pumps: 120 Vac/250 Vac, 5A, 1/3 HP
Maximum 2 x 14 AWG each on line voltage terminals Valves: 24 Vac, 0.5 A, 12 VA
Control and Zoning Panel Temperature Rating: 32 F to 130 F (0 C to Sensor Temperature Rating: -58 F to +230 F (-50 C to +110 C)
55 C) Supply/Return Sensor: Lead Length: 10 ft. (3050 mm). 10 kilohm NTC
Thermostat Compatibility: AQ1000 Series 2-wire communicating thermistor at 25 C (77 F) ±0.5F (±0.3C) up to 500 ft (150 M) using 18
thermostats and most digital thermostats AWG or larger wire
Zone Module Thermostat input: Low voltage, Class II, 2-wire polarity- Heat Demand (Thermostat R-W) Input: External dry contacts
insensitive, digital communicating with power link to AQ1000 series connection only
thermostat. Secondary Loop Mixing (Supply) Design Temp Range: 70 F to 210
Setback Program: 7 day, up to 2 setback periods/day. F (21 C to 99 C)

Components
Commercial
Boiler Design Temperature: 80F to 210F (26C to 99C) Secondary Loop Mixing (Supply) Max Control Temp Range: 80 F to
Boiler (Supply) Min. Control Temperature: OFF, 59F to 180F (OFF, 210 F (27 C to 99 C)
15C to 82C) Secondary Loop Return Min Control Temp Range: 80 F to 180 F (27
Boiler (Supply) Max. Control Temperature: (OFF, 120F to 225 F) C to 82 C)
OFF, 49C to 107 C Secondary Loop Mixing (Supply) Min Control Temp Range: 35 F to
Boiler Heat Post Purge: Off, 10 seconds to 30 minutes (factory default 150 F (2 C to 66 C)
is 30 seconds) B-B Communication Bus Terminals: Low voltage, Class II, 2-wire
Boiler (T-T) Output Rating: 24 Vac, 0.5A, 12VA polarity-insensitive, digital communicating link to other Control or
Pneumatic Controls

Boiler Differential: 2F to 41F (1C to 23C), or Auto (minimum 2 minutes Zoning modules.
on time) R-C Input (on Control and Zoning Modules): 24 Vac Class II (input
DHW Demand Input: External dry contacts connection only on Control and Zoning Modules)
Outdoor Low Design Control Temperature: -60F to 32F (-51 C to 0 R-C Output (on transformer): 38 VA, 24 Vac Class II
C) Operating Humidity Range (% RH): 5 to 90% RH, non-condensing
Return Minimum Control Temperature: 80 F to 180 F (27C to 82C) Weight: 6.0 lbs (2.7 kg)
Variable Speed Injection Pump Output: Triac modulated; 120 Vac, Approvals:
2.1A, 1/6HP Canadian Standards Association: CSA C/US Certified to CSA and
Industrial Combustion

Pump/Valve exercise: 30 seconds per 2 weeks of space heating UL Standards, File No. LR76030
inactivity
Controls

70-6910 207
AQUATROL Zoning System
Type of Mixing Valve Mixing DHW Pump/
Zoning Number of Floating Valve Valve
Devices Zones Output Modulating Boiler Pump Output
Product Number Controlled Controlled (Com,O,C) Output Output Rating Rating Replacement Parts
AQ25242B Zone pumps 4 24Vac rated 0-10 Vdc 120 Vac/250 120 Vac 5A, AQ15200B universal injection/mixing
or 2-wire dry contacts Vac 5A, 1/3HP 1/3HP boiler reset module
valves (line AQ12C11 supply/return/mixed loop sensor
voltage) AQ12C10 outdoor sensor
AQ10X38 24 Vac 38 VA transformer
AQ15540B 4-zone pump expansion
module
AQ25244B Zone valves 4 24Vac rated 0-10 Vdc 120 Vac/250 120 Vac 5A, AQ15200B universal injection/mixing
with end dry contacts Vac 5A, 1/3HP 1/3HP boiler reset module
switches AQ15740B 4-zone valve with end switch
expansion module
AQ12C11 supply/return/mixed loop sensor
AQ12C10 outdoor sensor
AQ10X38 24 Vac 38 VA transformer

AQ254 Add-a-Temperature Injection/Mixing Expansion Control Panel


for Hydronic Zoning System
• Acts as an add-on Control panel to the Main (AQ250, AQ25A,
AQ251, AQ252) Control panel.
• Allows each of the 16 zones connected to it to be assigned to the
system's primary or secondary loop.
• Up to 3 AQ254 panels can be added to a Main (AQ250, AQ25A,
AQ251 or AQ252) Control panel.
• Mixed loop temperature is controlled by a variable speed injection
pump or motorized mixing valve connected to the AQ254.
• Intuitive programming interface and armchair programming (can be
programmed at your desk and taken to the job site “ready-to-install”)
• Customizable mixing control settings allow for greater level of control
and comfort.
• Zone synchronization through Zone of Greatest Demand control.
• Integral 38 VA transformer with self resetting electronic fuse.
The AQ254 Add-a-Temperature Expansion Control Panel is used in
conjunction with an AQ250, AQ25A, AQ251 or AQ252 Control
Panel. It provides one additional loop temperature control
capability for the AQ2000 control panel it is connected to and
expands the total network capacity by up to 16 zones when used
with AQ255 and/or AQ257 zoning panels.
Application: Expanded zone control and mixed loop temperature Secondary Loop Mixing (Supply) Design Temp Range: 70 F to 210
control in a hydronic zoning system F (21 C to 99 C)
Mixed loop target temperature is reset by either outdoor temperature Secondary Loop Mixing (Supply) Max Control Temp Range: 80 F to
or calculated system load based on indoor temperature feedback 210 F (27 C to 99 C)
Mixing is target controlled by a variable speed injection pump or Secondary Loop Return Min Control Temp Range: 80 F to 180 F (27
motorized mixing valve C to 82 C)
Dimensions, Approximate: 9 1/2 in wide x 8 in. high x 3 3/8 in. deep Secondary Loop Mixing (Supply) Min Control Temp Range: 35 F to
(24 cm wide x 20.3 cm high x 8.5 cm deep) 150 F (2 C to 66 C)
Power Supply: 120V/60Hz B-B Communication Bus Terminals: Low voltage, Class II, 2-wire
Electrical Connections (Line Voltage): Wire-clamp screw terminals, polarity-insensitive, digital communicating link to other Control or
Maximum 2 x 14 AWG each on line voltage terminals Zoning modules.
Control and Zoning Panel Temperature Rating: 32 F to 130 F R-C Input (on Control and Zoning Modules): 24 Vac Class II (input
(0 C to 55 C) on Control and Zoning Modules)
Thermostat Compatibility: AQ1000 Series 2-wire communicating R-C Output (on transformer): 38 VA, 24 Vac Class II
thermostats and most digital thermostats Operating Humidity Range (% RH): 5 to 90% RH, non-condensing
Variable Speed Injection Pump Output: Triac modulated; 120 Vac, Weight: 3.9 lbs (1.8 kg)
2.1A, 1/6HP
Approvals:
Secondary Pump Output Rating: 120 Vac 5A, 1/3HP Canadian Standards Association: CSA C/US Certified to CSA and
Auxiliary Pump Output Rating: Dry contact output, 120 Vac/250 Vac UL Standards, File No. LR76030
5A, 1/3 HP
Sensor Temperature Rating: -58 F to +230 F (-50 C to +110 C)

Mixing Valve Floating User Interface (Setting,


Product Number Output (Com,O,C) Programming) Replacement Parts
AQ25400B 24Vac rated dry contacts LCD Display and a 3 button AQ15400B Add-A-Temperature expansion control module;
Key Pad AQ12C11 supply/return/mixed loop sensor;
AQ10X38 24 Vac 38 VA transformer

208 customer.honeywell.com 70-6910


AQUATROL Zoning System
AQ255 and AQ257 Zoning Expansion Panel for Hydronic Zoning

Controls
Home
System
The AQ255 and AQ257 family of AQUATROL Expansion Zoning
panels work with AQ2000 Boiler Control Panels and AQ1000
Communicating Thermostats to control up to 4 space heating
zones (or 8, for the AQ25582B Panel). Can be combined with
additional expansion zoning panels and an AQ2000 control panel

Indoor Air Quality


for a total of 16 space heating zones.
• AQ257 for zoning with zone valves with end switches
• Auto test function to test zones at system start up. It allows for
operator controlled testing of zones; includes pause/restart
capability.
• LED lights for visual diagnostic of zone operation.
• Allows zoning with either "Normally Open" or "Normally Closed"
zone valves.
• Adjacent zoning panels can operate different zone equipment - one

Combustion Controls
panel may control 4 pumps while another may control 4 zone valves.
• Easily switch from zone valves to pumps with same zoning module -

Residential
just flip one DIP switch. Ensure correct voltage is applied to all zone
equipment on a panel (120 Vac for pumps, 24 Vac for valves)
• R-C transformer and B-B data bus terminal connections (network
communication) for easy expansion.
• Zones can be set to energize a group pump via Aux Out dry contacts
on main control panel (AQ250, AQ25A, AQ251, AQ252) or
expansion control panel (AQ254).
• Zone synchronization through Zone of Greatest Demand control.

Hydronic Controls
• 38 VA Transformer with self resetting electronic fuse.

Application: Zoning control for hydronic zoning system Zone Output Contact Rating: 120 Vac/250 Vac, 5A, 1/3 HP
Dimensions, Approximate: 9 1/2 in wide x 8 in. high x 3 3/8 in. deep B-B Communication Bus Terminals: Low voltage, Class II, 2-wire
(24 cm wide x 20.3 cm high x 8.5 cm deep) polarity-insensitive, digital communicating link to other Control or
User Interface (Setting, Programming): (DIP Switches) Zoning modules.
Electrical Connections (Line Voltage): Wire-clamp screw terminals, R-C Input (on Control and Zoning Modules): 24 Vac Class II (input
Maximum 2 x 14 AWG each on line voltage terminals on Control and Zoning Modules)
Control and Zoning Panel Temperature Rating: 32 F to 130 F (0 C to Operating Humidity Range (% RH): 5 to 90% RH, non-condensing

Controls
Water
55 C) Weight: 2.1 lbs (1 kg)
Thermostat Compatibility: AQ1000 Series 2-wire communicating
Approvals:
thermostats and most digital thermostats Canadian Standards Association: CSA C/US Certified to CSA and
Zone Module Thermostat input: Low voltage, Class II, 2-wire polarity- UL Standards, File No. LR76030
insensitive, digital communicating with power link to AQ1000 series
thermostat.

Building Automation
Number of Weight
Type of Zoning Devices Zones
Product Number Controlled Controlled (kg) (lb) Replacement Parts
AQ25542B Zone pumps or 2-wire valves (line 4 1 kg 2.1 lbs AQ15540B 4-zone pump expansion module
voltage)
AQ25582B Zone pumps or 2-wire valves (line 8 1.3 kg 2.6 lbs AQ15540B 4-zone pump expansion module
voltage)
AQ25742B 2-wire valve (24 Vac) 4 1.8 kg 3.9 lbs AQ10X38 24 Vac 38 VA transformer;
AQ15540B 4-zone pump expansion module

Components
Commercial
AQ25744B Zone valves with end switches (24 4 1.8 kg 3.9 lbs AQ15740B 4-zone valve with end switch expansion module;
Vac) AQ10X38 24 Vac 38 VA transformer

Pneumatic Controls
Industrial Combustion
Controls

70-6910 209
AQUATROL Zoning System
AQ2000 Series Replacement Control Modules
Dimensions, Approximate
AQ15000B and AQ15400B: 3 1/2 in wide x 2 1/2 in high x 4 1/4 in wide
(9 cm wide x 94 cm high x 10.09 cm deep)
AQ15100B, AQ15200B and AQ15A00B:
7 1/8 in wide x 2 1/2 in high x 4 1/4 in deep
(18 cm wide x 94 cm high x 10.09 cm deep)
Electrical Connections (Line Voltage): Wire-clamp screw terminals,
Maximum 2 x 14 AWG each on line voltage terminals
Control and Zoning Panel Temperature Rating: 32 F to 130 F (0 C to
55 C)
Boiler Heat Post Purge: Off, 10 seconds to 30 minutes (factory default
is 30 seconds)
Boiler (T-T) Output Rating: 24 Vac, 0.5A, 12VA
Boiler Differential: 2F to 41F (1C to 23C), or Auto (minimum 2 minutes
on time)
DHW Demand Input: External dry contacts connection only
Pump/Valve exercise: 30 seconds per 2 weeks of space heating
inactivity
Slab/Floor Sensor: Heat Demand (Thermostat R-W) Input: External
dry contacts connection only
B-B Communication Bus Terminals: Low voltage, Class II, 2-wire
polarity-insensitive, digital communicating link to other Control or
Zoning modules.
R-C Input (on Control and Zoning Modules): 24 Vac Class II (input
on Control and Zoning Modules)
Operating Humidity Range (% RH): 5 to 90% RH, non-condensing
Weight
AQ15000B: 0.5 lbs (0.23 kg)
AQ15400B: 0.7 lbs (0.3 kg)
AQ15100B, AQ15200B and AQ15A00B: 1.0 lbs (0.5 kg
Replacement control modules for AQ2000 panels Approvals:
Canadian Standards Association: CSA C/US Certified to CSA and UL
Standards, File No. LR76030

Product Number Mixing Valve Floating Output (Com,O,C) Mixing Valve Modulating Output User Interface (Setting, Programming)
AQ15000B — — DIP Switches
AQ15100B — 0-10 Vdc to boiler LCD Display and a 7 button Key Pad
AQ15200B 24Vac rated dry contacts 0-10 Vdc to boiler or mixing valve LCD Display and a 7 button Key Pad
AQ15400B 24Vac rated dry contacts 0-10 Vdc to mixing valve LCD Display and a 3 button Key Pad
AQ15A00B — 0-10 Vdc to boiler LCD Display and a 7 button Key Pad

AQ2000 Series Replacement Zoning Modules


Dimensions, Approximate: 3 1/2 in wide x 2 1/2 in high x 4 1/4 in deep
(9 cm wide x 94 cm high x 10.09 cm deep)
Electrical Connections (Line Voltage): Wire-clamp screw terminals,
Maximum 2 x 14 AWG each on line voltage terminals
Control and Zoning Panel Temperature Rating: 32 F to 130 F (0 C to
55 C)
Thermostat Compatibility: AQ1000 Series 2-wire communicating
thermostats and most digital thermostats
Zone Module Thermostat input: Low voltage, Class II, 2-wire polarity-
insensitive, digital communicating with power link to AQ1000 series
thermostat.
Zone Output Contact Rating: 120 Vac/250 Vac, 5A, 1/3 HP
B-B Communication Bus Terminals: Low voltage, Class II, 2-wire
polarity-insensitive, digital communicating link to other Control or
Zoning modules.
R-C Input (on Control and Zoning Modules): 24 Vac Class II (input
on Control and Zoning Modules)
Operating Humidity Range (% RH): 5 to 90% RH, non-condensing
Replacement Zoning Modules for AQ2000 panels Weight: 0.6 lbs (0.3 kg)
Approvals:
Canadian Standards Association: CSA C/US Certified to CSA and UL
Standards, File No. LR76030

Product Number Type of Zoning Devices Controlled Number of Zones Controlled User Interface (Setting, Programming)
AQ15540B Zone pumps or 2-wire valves (line voltage) 4 (Non-communicating) DIP Switches
AQ15740B Zone valves with end switches 4 (Non-communicating) DIP Switches

210 customer.honeywell.com 70-6910


AQUATROL Zoning System
AQ2000 Series Accessories and Replacement Parts

Controls
Home
Product Number Description
AQ10X38 Replacement transformer module for AQ250, AQ25A, AQ251, AQ252, AQ254, AQ257 and
AQ25742B series control and zoning panels. It can be used to add an additional 38 VA power per
transformer to drive high VA devices.

Indoor Air Quality


Combustion Controls
AQ11D10 Replacement enclosure for AQ25400B, AQ25542B, AQ25742B, AQ25744B, AQ25582B panels,
Consists of case, cover, and DIN rail for mounting of transformer, control or zoning modules. It can

Residential
be used to add extra AQ10X38 transformers or hide system wiring and component.

AQ11D15 Replacement enclosure for AQ25042B, AQ25044B, AQ25110B panels. Consists of case, cover,
and DIN rail for mounting of transformer, control or zoning modules. It can be used to add extra
AQ10X38 transformers or hide system wiring and component.

AQ11D20 Replacement enclosure for AQ25A42B, AQ25A44B, AQ25142B, AQ25144B, AQ25242B, and
AQ25244B panels. Consists of case, cover, and DIN rail for mounting of transformer, control or

Hydronic Controls
zoning modules.; It can be used to add extra AQ10X38 transformers or hide system wiring and
component.
AQ12C10 Outdoor Sensor with 10 feet of lead wires and a plastic mounting bracket for use with AQ2000
Series Programmable Control Panels.

Controls
Water
AQ12C11 Supply/Return/Mixed Loop Pipe Sensor with 10 feet of lead wires for use with AQ2000 Series
Control Panels.

Building Automation
AQ12C20 Slab/Floor Sensor of 15 feet lead length. It is sold separately for use with AQ1000 Series
Thermostats to control floor temperatures of in-floor radiant heating applications.

Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 211
AQUATROL Zoning System
AQ1000TN2 Non-Programmable Communicating Thermostat
The AQ1000TN2 thermostat is used to control the ambient air
temperature or floor temperature in hydronic heating applications.
It communicates with and is powered by an AQ2000 series zoning
module to provide zoning control.
• 2-wire polarity-insensitive non-programmable network
communicating thermostat.
• Liquid crystal display with user buttons .
• Outdoor, indoor and floor temperature displays.
• Floor temperature sensing with minimum and maximum limits (when
used with optional AQ12C20 Slab/Floor Sensor - sold separately)
• Selectable temporary and permanent backlight.

Application: Hydronic single-stage zoning heat Mounting: Vertical Mount


Network Zoning: Yes Color: Premier White®
Zones: Single or Multi-zone Temperature Control Mode Selections: "A" for Ambient Air, "F" for
Dimensions, Approximate: 2.8 in wide x 4.6 in high x 1.0 in deep Floor, "AF" for Ambient & Floor.
(7 cm wide x 12 cm in high x 2.5 cm deep) Temperatures Displayed: Indoor, Set Point, Outdoor
Electrical Connections: Wire-clamp screw terminals Temperature Display Interval: ±1.0 F (±0.5 C)
Network Bus: Low voltage, Class II, 2-wire polarity-insensitive, digital Floor Sensor Temperature Rating: -58F to 230F (-50C to 110C)
communicating link to AQ2000 series zoning modules. Floor Temperature Limit Range (AF Model):
User Interface (Programming): LCD Display 40 F to 100 F (5 C to 38 C)
User Interface (System Configuration): DIP Switches Outdoor Temperature Display Range: -58 F to 149 F (-50C to 65 C)
Thermostat Type: 2-wire Communicating Thermostat Ambient Temperature Range: 32 F to 158 F (0 C to 70 C)
Sensor Element: Thermistor Temperature Range, Storage: -20 F to 130 F (-30 C to 55 C)
Sensors (Floor) Used: 10 kilohm NTC thermistor at 25 C (77 F) Operating Humidity Range (% RH): 5 to 90% RH, non-condensing
±0.5F (±0.3C) up to 500 ft (150 M) using 18 AWG or larger wire, Weight: 0.2 lb (0.1 kg)
beta=3892. Lead Length: 10 ft. (3050 mm).

Setting Temperature Differential


Range Temperature
Terminal Type of Control LCD Icons Displayed
Product Number (F) (C) (F) (C) Designations Provided (Mode) Power Method
AQ1000TN2 40 F to 100 F 5 C to 38 C ±1F ±0.5 C TH, TH, Sensor, Proportional Vacation Mode; Powered (24 Vdc) by
Sensor Integral (PI) Set point; AQ zoning module
Keypad Lock;
Comfort/Unoccupied;
Heat On

212 customer.honeywell.com 70-6910


AQUATROL Zoning System
AQ1000TP2 Programmable Heat/Cool Thermostat

Controls
Home
The AQ1000TP2 thermostat is used to control the ambient air
temperature or floor temperature in hydronic heating applications.
It communicates with and is powered by an AQ2000 series zoning
module to provide zoning control.
• 2-wire polarity-insensitive programmable network communicating
thermostat
• Liquid crystal display, with 7 user buttons for programming

Indoor Air Quality


• Floor temperature sensing with minimum and maximum limits (when
used with optional AQ12C20 Slab/Floor Sensor - sold separately)
• 7-day programmable
• Single-stage Heating and Cooling
• Outdoor, indoor, and floor temperature display
• Selectable temporary and permanent backlit

Combustion Controls
Residential
Application: Hydronic single-stage zoning, heating and cooling Mounting: Vertical Mount
Network Zoning: Yes Color: Premier White®

Hydronic Controls
Zones: Single or Multi-zone Temperature Control Mode Selections: "Air" for Ambient Air, "Floor"
Dimensions, Approximate: 3.0 in. wide x 4.9 in. high x 1.0 in. deep for Floor, "Air/Floor" for Ambient & Floor limits
(7.8 cm wide x 12.5 cm high 2.5 cm deep) Temperatures Displayed: Indoor, Set Point, Outdoor
Electrical Connections: Wire-clamp screw terminals Temperature Display Interval: (±0.5 C)
Network Bus: Low voltage, Class II, 2-wire polarity-insensitive, digital Floor Sensor Temperature Rating: -58F to 230F (-50C to 110C)
communicating link to AQ2000 series zoning modules. Floor Temperature Limit Range (Air/Floor Model):
User Interface (Programming): LCD Display and 7 user programming 40 F to 100 F (5 C to 38 C)
buttons Outdoor Temperature Display Range: -58 F to 149 F (-50C to 65 C)
User Interface (System Configuration): DIP Switches Ambient Temperature Range: 32 F to 158 F (0 C to 70 C)
Thermostat Type: 2-wire Communicating Thermostat Temperature Range, Storage: -20 F to 130 F (-30 C to 55 C)
Sensor Element: Thermistor Operating Humidity Range (% RH): 5 to 90% RH, non-condensing

Controls
Sensors (Floor) Used: 10 kilohm NTC thermistor at 25 C (77 F) Weight: 0.3 lb (0.5 kg)

Water
±0.5F (±0.3C) up to 500 ft (150 M) using 18 AWG or larger wire,
beta=3892. Lead Length: 10 ft. (3050 mm).

Setting
Temperature Differential
Range Temperature
Terminal Type of Control LCD Icons

Building Automation
Product Number (F) (C) (F) (C) Designations Programmability Provided Displayed (Mode) Power Method
AQ1000TP2 40 F to 5 C to ±1F ±0.5 C TH, TH, 7-day Proportional Fan On; Powered (24 Vdc)
100 F 38 C Sensor, Sensor programmable Integral (PI) Vacation Mode; by AQ zoning
Cool On; module
Set point;
Keypad Lock;
Comfort/Unoccupied;
Heat On

Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 213
Hydronic Switching Relays
R182 Hydronic Switching Relay
Enclosed intermediate relays for 24 volt thermostat control of line Contact Electrical Ratings
voltage devices. 120 Vac AFL: 7.4A
120 Vac ALR: 44.4A
Application: For 24 V thermostat control of line voltage devices 240 Vac AFL: 3.7A
Dimensions, Approximate: 5 1/4 in. long x 4 1/4 in. wide x 3 in. deep 240 Vac ALR: 22.2A
(133 mm long x 108 mm wide x 77 mm deep) Transformer Primary Rating: 120 Vac, 50/60 Hz
Thermostat Compatibility: Low voltage 2 or 3-wire Transformer Secondary Rating: 24 Vac, 50/60 Hz
Coil Ratings Approvals:
Voltage: 24 Vac, 50/60 Hz Canadian Standards Association: Certified
Current: 0.35A Underwriters Laboratories, Inc. Listed: File No. E4436, Guide No.
XAPX

Electrical
Connections Electrical Ratings: Switching
Product Number (Control Circuit) Primary Voltage Action Description
* R182C1051 2 or 3-wire 120V, 50/60 Hz DPDT Switching relay with internal transformer, two line voltage SPDT relays
* TRADELINE models • SUPER TRADELINE models

R856 Control Center


Provides 24 volt control of line voltage motors, fans, blowers, or
pumps up to 1 hp.
• Integral 45 VA transformer to supply low voltage power for the
system.
• Low voltage terminal strip for easy thermostat and panel
connections.

Application: Fan relay and transformer in an enclosure.


Dimensions, Approximate: 7 1/8 in. high x 4 1/2 in. wide x 3 5/16 in.
deep (181 mm high x 114 mm wide x 84 mm deep)
Contact Electrical Ratings
120 Vac AFL: 14.0A N.O.; 10.0A N.C.
120 Vac ALR: 84.0A N.C.; 80.0A N.C.
Horsepower: 3/4 hp N.O.; 1/2 hp N.C.
Approvals:
Canadian Standards Association: Certified: File No. LR95329-1
Underwriters Laboratories, Inc. Listed: File No. E4436, Vol. 6 Sec. 9

Coil Ratings
Electrical Ratings:
Product Number Voltage Current (Inrush) (Sealed) Primary Voltage Switching Action Description
R856B1002 24 Vac 0.22A 11 VA 6 VA 120V, 60 Hz SPST 120V, 60 Hz Fan Relay with Spst switching

214 customer.honeywell.com 70-6910


Hydronic Switching Relays
R847 Heavy Duty Relay

Controls
Home
Designed for control of relatively heavy duty 120 or 240 Vac
electrical loads such as cooling compressors.
• Internal, flexible leads permit SPST or DPST switching.

Indoor Air Quality


R847A wired to break one side of the circuit with SPST switching. Application: Enclosed switching relay with internal transformer that

Combustion Controls
provides 24V power for control circuit. It provides switching for high
current load applications.

Residential
Dimensions, Approximate: 5 1/4 in. high x 4 1/4 in. wide x 2 3/4 in.
R847A deep (133 mm high x 108 mm wide x 70 mm deep)
Electrical Connections (main): 2-Wire
Contact Electrical Ratings
120 Vac AFL: 22A
T T 120 Vac ALR: 100A
240 Vac AFL: 10A

Hydronic Controls
240 Vac ALR: 50A
THERMOSTAT
Approvals:
Canadian Standards Association: Certified: File No. LR1620
Underwriters Laboratories, Inc. Listed: File No. SA481, Guide No.
MOVE SDF4
FLEXIBLE
LEAD
TO L1 L2 L1 3 4

Controls
Water
ADD
POWER JUMPER LOAD
SUPPLY M16562

Coil Ratings
Maximum

Building Automation
Pull-in Electrical Ratings: Switching
Product Number Voltage Current Inrush Sealed Voltage Primary Voltage Action Description
* R847A1085 24 Vac 0.4A 21.4 VA 8.4 VA 20 120V, 50/60 Hz DPST or SPST 120V, 50/60 Hz Heavy Duty Switching
Relay with integral transform, Dpst or
Spst line voltage relays
* TRADELINE models • SUPER TRADELINE models

Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 215
Hydronic Switching Relays
RA89; RA832; R845 Hydronic Switching Relay
Provide intermediate switching of a line voltage device from a low
voltage controller.
• Integral transformer provides low voltage power for control circuit.

Application: Provide intermediate switching of a line voltage device


form a low voltage controller.
Dimensions, Approximate: 5 1/4 in. high x 4 1/4 in. wide x 2 5/16 in.
deep (133 mm high x 108 mm wide x 59 mm deep)
Electrical Connections (Control Circuit): 2-Wire
Electrical Rating: Maximum Input: 5.0 W
Transformer Primary Rating: 120 Vac, 50/60 Hz
Transformer Secondary Rating: 24 Vac
Coil Ratings:
Voltage: 24 Vac
Current: 0.4A
Thermostat Compatibility: Low voltage (Class 2) 2-wire
Temperature Range: 115 F maximum ambient for 60 Hz. 105 F Max.
Ambient for 50 Hz. (46 C maximum ambient for 60 Hz. 41 C maximum
ambient for 50 Hz.)
Includes: Integral transformer, enclosure
Approvals:
Canadian Standards Association: Certified: File No. LR1620
Underwriters Laboratories, Inc. Listed: File No. E4436, Guide No.
XAPX

Contact Electrical Ratings


Contacts Maximum Main Contacts Secondary Contacts
Connected Loaded Millivolt Pilot Duty
(120-240 Vac) 120 Vac 240 Vac 120 Vac 240 Vac DC Rating Rating Rating
R845 2000 VA 7.4A AFL; 44.4A ALR; 3.7A ALF; 22.2A ALR; 3A ALF; 2A AFL; — — 50 VA @ 24V
10A Resistive 6.0A Resistive 18A ALR 12A ALR
RA832 2000 VA 7.4A AFL; 44.4A ALR; 3.7A ALF; 22.2A ALR; — — 1A @ 12 Vdc 300 mA min. @ 50 VA @ 24V
10A Resistive 6.0A Resistive 750 mV
RA89 — 10.2A AFL; 61.2A 5.1AA ALF; 30.6A — — — — —
ALR; 10A Resistive ALR; 6.0A Resistive

Electrical
Ratings:
Product Number Primary Voltage Switching Action Description
* R845A1030 120V, 50/60 Hz DPST; one pole line voltage, the Switching relay with internal transformer, provides Dpst switching for hot water
other line or low voltage zone control systems, or spst control of two separate loads.
* RA832A1066 120V, 50/60 Hz DPST; one pole line voltage, the Switching Relay with internal transformer, for switching two line voltage loads
other low voltage or millivolt having a common power source.
* RA832A1074 240V, 50/60 Hz DPST; one pole line voltage, the Switching Relay with internal transformer, for switching two line voltage loads
other low voltage or millivolt having a common power source.
* RA89A1074 120V, 50/60 Hz SPST Switching Relay with internal transformer, for switching one line voltage load.
* TRADELINE models • SUPER TRADELINE models

216 customer.honeywell.com 70-6910


Hydronic Switching Relays
R8845U Universal Switching Relay

Controls
Home
The R8845U Universal Switching Relay with 24 V transformer
provides intermediate switching of line-and low-voltage devices
from a line- or low-voltage controller and is typically applied in
Hydronic heating systems.
• Replaceable socketed relays.
• Two troubleshooting LED.
• Push-to-test button.

Indoor Air Quality


• Replaceable transformer fuse.
• Low-voltage contact rating for Powerpile applications.
• Long-life DC relay drive control technology.
• Relay for use with external 24 Vac or 24 Vdc supply, with line-voltage
control, or with internal 24 V transformer supply.
• One model replaces many competitor models.
• One model may replace many Honeywell models:R182A,B,C,J;
R482A,B,C,J; R845; R882A,B,C,J and RA832.

Combustion Controls
Residential
Dimensions in inches (millimeters) Application: Provides intermediate switching of line and low voltage
devices from a line or low voltage controller
4-7/16 (118) Transformer Primary Rating: 120 Vac, 60 Hz
1-3/8 (35) Transformer Secondary Rating: 24 Vac, 12 VA max., 9 VA available
for external load. Secondary protected by replaceable 1A automotive
fuse.

2-1/8
Contact Electrical Rating
(54) 120 Vac AFL: 7.4A AFL, 44.4A ALR on each set of line-voltage

Hydronic Controls
7/8(22) contacts. Maximum connected load is 2000 VA.
DIAMETER
Thermostat Compatibility: Honeywell electromechanical and
electronic 2- or 3-wire
Thermostat Heat Anticipator Setting: 0.12A
Temperature Range: (Ambient) -20 F to +120 F ((Ambient) -29 C to
KEYHOLE
TYPE +49 C)
3/16 (5) DIAMETER
MOUNTING Operating Humidity Range (% RH): 0 to 90% RH, non-condensing
HOLE
3/8 (10) DIAMETER Replacement Parts: 32002190-001 Circulator Replacement Relay
Includes: Integral transformer, enclosure
Approvals:
Canadian Underwriters Laboratories, Inc. Listed: Guide No. XAPX7.

Controls
Water
Underwriters Laboratories, Inc. Listed: File No. E4436, Guide No.
5-3/8
(137)
XAPX

6-1/4
(159)

Building Automation
7/32 (6)
DIAMETER
MOUNTING
HOLE

5/16 (8)

3-11/16 (94) 5/16


(8)
KNOCKOUT
FOR 1/2 (13)
CONDUIT (3)

Components
Commercial
3-1/2
(89)

2-3/16
(56)
Pneumatic Controls

1-1/16 1-1/4 (32)


(27) M17512

Coil Ratings
Electrical Connections Electrical Ratings:
Product Number Voltage Current (Control Circuit) Primary Voltage Switching Action
R8845U1003 24 Vac 0.4A 2 or 3-wire 120V, 60 Hz Two SPST, plus PowerPile® rated low voltage SPST relay. (If
normally closed contacts are needed, use RA889A).
Industrial Combustion
Controls

70-6910 217
Hydronic Switching Relays
R8845U Replacement Cross Reference
Connections
Input Line Power Power Low Voltage
Manufacturer Model Voltage Relay 1 Relay 2 Relay Thermostat Comments
Honeywell R8845U L1 L2 COM N.O. A B X1 X2 W(T) R(T) C —
Honeywell R845A 1 2 3 4 5 6 — — T T — —
Honeywell RA832A 1 2 — 3 — 4 X X T T — Jumper L1 to COM and A in R8845U.
Honeywell R182A 1 2 7 8 — — — — THREE-WIRE TWO-WIRE R8845U has lower output load rating. Check
Honeywell R182B 1 3 6 8 — — — —
LOW VOLTAGE
(SERIES 10)
LOW VOLTAGE
(SERIES 80)
load requirements. Use RA889A if normally
Honeywell R182C 1 2 6 8 3 5 — —
THERMOSTAT
1
THERMOSTAT closed contacts are required.
W(T) R(T) B R W
Honeywell R182J L1 L2 — 4 — 7 — — If used to replace an R182J, install a jumper
between L1, COM and A.

R(T) C W(T) X1 X2 R(T) C W(T) X1 X2

R8845U R8845U

1 MAKES CONTACT ONLY ON TEMPERATURE FALL.


M18268

Honeywell R482A 1 2 7 8 — — — — Jumper R(T) to W(T). Line voltage switched inputs go to L1 and L2.
LINE VOLTAGE R8845U
CONTROL
1 L1 R(T)
JUMPER
NEUTRAL
L2 W(T)

C
COM

N.O.

A X1

B X2

1 WARNING! ELECTROCUTION HAZARD.


POWER SUPPLY CAN CAUSE SEVERE INJURY
OR DEATH. DISCONNECT POWER BEFORE
WIRING OR SERVICING L1. POWERED RELAYS
MUST BE WIRED AS DRY CONTACTS.
M18269

Honeywell R482B 1 2 6 8 — — — Use RA889A if normally closed contacts are


Honeywell R482C 1 2 6 8 3 5 — — required. Line voltage switched inputs go to
Honeywell R482J 1 2 6 8 3 4 — — L1 and L2.
Honeywell R882A — — 7 8 — — — — W — B R8845U has lower output load rating. Check
load requirements.
Honeywell R882B — — 6 8 — — — — W — B Use RA889A if normally closed contacts are
Honeywell R882C — — 6 8 3 5 — — W — B required.
Honeywell R882J — — 6 8 3 4 — — 1 — 2
Argo AR821 1 2 3 4 5 6 — — T T — R8845U has lower output load rating. Check
load requirements.
Argo AR822 L1 L2 3 4 N.O. 5 6 — — G(T) R(T) C Use RA889A if normally closed contacts are
N.O. required.
Erie SR100AT L1 N 3 4 N.O. 5 6 — — G(T) R(T) C
N.O.
White-Rodgers 829-189 1 2 3 4 — — — — B R W R8845U has lower output load rating. Check
White-Rodgers 829-832 1 2 — 4 — 3 X1 X2 T T — load requirements.
Taco SR501 H N 3 4 N.O. 5 6 — — W(T) R(T) C Use RA889A if normally closed contacts are
N.O. required.

218 customer.honeywell.com 70-6910


Hydronic Switching Relays
RA889A Switching Relay

Controls
Home
The RA889A Switching Relay with 24 V controller provides
intermediate switching of line- and low-voltage devices from a line-
or low-voltage controller and is typically applied in Hydronic
heating systems.
• High load switching capability.
• Troubleshooting LED.
• Push-to-test button.

Indoor Air Quality


• Replaceable transformer fuse.
• Long-life DC relay drive control technology.
• Relay for use with external 24 Vac or 24 Vdc supply, with line-voltage
control, or with internal 24 V transformer supply.
• One model replaces many Honeywell models.
• Secondary of transformer protected by replaceable 1A automotive
fuse.

Combustion Controls
Residential
Dimensions in inches (millimeters) Application: For switching of line- and low-voltage devices from a line-
or low-voltage controller.
4-7/16 (118) Electrical Connections (main): No. 8 captive wire clamp screw
1-3/8 (35) terminals.
Contact Electrical Ratings
Contacts Maximum Connected Loaded (120-240 Vac): 2000 VA
120 Vac AFL: 15A
120 Vac ALR: 30A

Hydronic Controls
2-1/8
(54)
7/8(22) Transformer Primary Rating: 120 Vac, 60 Hz
DIAMETER Transformer Secondary Rating: 24 Vac, 12 VA max., 9 VA available
for external load. Secondary protected by replaceable 1A automotive
fuse.
Thermostat Compatibility: Honeywell electromechanical and
KEYHOLE electronic 2- or 3-wire
3/16 (5) DIAMETER TYPE Thermostat Heat Anticipator Setting: 0.12A
MOUNTING
3/8 (10) DIAMETER HOLE Temperature Range: (Ambient) -20 F to +120 F (-29 C to +49 C)
Operating Humidity Range (% RH): 0 to 90% RH, non-condensing
Includes: Integral transformer, enclosure

Controls
Approvals:

Water
Canadian Underwriters Laboratories, Inc. Listed: Guide No. XAPX7.
5-3/8 Underwriters Laboratories, Inc. Listed: File No. E4436, Guide No.
(137) XAPX

6-1/4

Building Automation
(159)
7/32 (6)
DIAMETER
MOUNTING
HOLE

5/16 (8)

3-11/16 (94) 5/16


(8)
KNOCKOUT
FOR 1/2 (13)

Components
Commercial
CONDUIT (3)
3-1/2
(89)

2-3/16
(56) Pneumatic Controls

1-1/16 1-1/4 (32)


(27) M17512

Electrical Ratings:
Product Number Primary Voltage Switching Action Description
RA889A1001 120V, 60 Hz SPDT, plus PowerPile® rated Enclosed switching relay with internal transformer, Spdt line voltage relay, plus
low voltage SPST relay Spst low voltage relay with Powerpile rating. 120V/60Hz 15 AFL/30 ALR ratings
one line voltage contacts.
Industrial Combustion
Controls

70-6910 219
Hydronic Switching Relays
RA889A Replacement Cross Reference.
Connections
Input Line Low Voltage
Model Voltage Power Relaya Relay Thermostat Comments
RA889A L1 L2 COM N.O. N.C. X1 X2 W(T) R(T) C —
RA89Ab 1 2 3 4 — — — T T — —
R482B 1 2 8 6 7 — — Jumper R(T) to W(T). Line voltage switched inputs go to L1 and L2.
LINE VOLTAGE R8845U
CONTROL
1 L1 R(T)
JUMPER
NEUTRAL
L2 W(T)

C
COM

N.O.

A X1

B X2

1 WARNING! ELECTROCUTION HAZARD.


POWER SUPPLY CAN CAUSE SEVERE INJURY
OR DEATH. DISCONNECT POWER BEFORE
WIRING OR SERVICING L1. POWERED RELAYS
MUST BE WIRED AS DRY CONTACTS.
M18269

R882Ab — — 8 7 — — — W — B —
R882B — — 8 6 7 — — W — B

220 customer.honeywell.com 70-6910


Transformer for Hydronic Heating Controls
AT140 General Purpose Transformer for Hydronic Heating Controls

Controls
Home
Provide power to 24 Vac circuits in heating/cooling control
systems. Intended for use in systems with predictable, uniform
loads. Can be used in any application that does not exceed the
listed ratings.
• Rated at 40 VA.
• Color-coded leadwires for primary connections and screw terminals
for secondary connections, fixed 1/4 inch (6 mm) male quick-

Indoor Air Quality


connects or color-coded leadwires for both primary and secondary,
are standard.
• Meet NEC Class 2 requirements.
• Meet Underwriters Laboratories Inc. Standard UL 1585 and are
identified. Class 2 not wet, Class 3 wet.

Temperature Rating: -20 F to +105 F (-29 C to +41 C)


Frequency: 60 Hz

Combustion Controls
Approvals:
Canadian Standards Association: CSA Certified: A & B models.

Residential
Underwriters Laboratories, Inc. UL Listed: A,C,F models. File #
E14881

Electrical Connections
Dimensions, Approximate Electrical Ratings (main)
Voltage
Product Number (inch) (mm) Primary Secondary Output Primary Secondary Mounting

Hydronic Controls
AT140A1034 3 3/16 in. high x 81 mm high x 120 Vac 27 V.O.C. 24 Vac at 9 in. leadwires (2) screw Foot mounted, plate mounted on
2 3/8 in. wide x 60 mm wide x 20 VA terminals 2x4 in. or 4x4 in. outlet box,
3 1/8 in. deep 79 mm deep clamp mounted using outlet box
knockout, or panel mounted

Dimensions in inches (millimeters)

PLATE OR OUTLET BOX MOUNTING PLATE


PLATE MOUNTED AT THE FOOT MOUNTED
MOUNTED AT CLAMP LAMINATIONS (3/4 ABOVE 3-3/8 (86)
ON END BELL (ALL PLATE MOUNTING) 3-1/16 (78) 1/8 (3)

Controls
ABOVE PLATE MOUNTING)

Water
2-15/16 (76) 1-1/16 2 (51)
(27)
3-7/32
82 1/4
2-1/4 1/8 (6)
(57) (3) 4-3/16
(106)

Building Automation
2-3/8
(60) 3-3/8
2
(51) (86)
D

1-3/4
(44)
2-3/8 3 -1/4 (83)
5/16 (8)
(60)

M17509A

Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 221
Residential Heating Valves and Actuators
V5442N Rotary Valve
The Corona series of Compact Rotary Valves and Actuators
provide integrated mixing of boiler supply, boiler return, loop
supply, and loop return water in hydronic heating systems. The
V5442 valve can mix both loop supply water and boiler return
water simultaneously to control loop supply temperature and
boiler shock or flue gas condensation protection. They may be
plumbed in either a direct mixing or injection configuration. The
effective Cv of the valves is increased when piped in an injection
configuration.
NOTE: Valve cannot be used in open systems such as Combo
heating where fresh water is present. Valve will corrode.
• Valves can be automated with M6063 actuator.
• 4-way mixing action for closed hydronic heating systems.
• Mixes loop supply with boiler supply and loop return.
• Mixes boiler return with boiler supply and loop return.
• Optimized mixing characteristics for most accurate control.
• Cast iron body; chrome plated plug.
• NPT threads.
• Suitable for manual or automatic control.
• Universal body orients either to the left or right to match piping.
• Functional replacement for Centra ZRK-series of compact 4-way
mixing valves.

Dimensions in inches (millimeters) Coupling Controller: M6063A


Inlet Size: 1 1/2 in. (DN40)
Differential (close-off) Pressure Rating: 15 psi (1Bar)
a SW Static Pressure Rating: 90 psi (6 Bar)
Median Temperature Range: 36 F to 230 F (2 C to 110 C)
Shipping Temperature Range: -40 F to +140 F (-40 C to +60 C)
Leakage: Less than 1% of Cv.
a Materials
i (Body): Cast Iron
(Interior Parts): Chrome-plated cast iron
(Seal): Double O-rings
Comments: Valve cannot be used in open systems such as Combo
heating where fresh water is present. Valve will corrode.
C Use with max. 50% glycol in water solution

Size [i] [a] [SW] [C] [C] with actuator


3/4” 3 3/8” 1 5/8” 13 3/8”
1” (85 mm) (41 mm) (304 mm) 13 3/4”
4 1/8” 1 13/16” 13 9/16” (350 mm)
1 1/4” (46 mm) (345 mm)
(105 mm)
M23253

Pipe Size Capacity


Product Number (inch) (DN) Body Pattern (Cv) (Kvs) Pipe Connection Used With
V5442N1015 3/4 in. DN20 Rotary 7.4 Cv 6 kvs NPT (Internal Thread) Must be used with M6063 actuator.
V5442N1023 1 in. DN25 Rotary 11.7 Cv 10 kvs NPT (Internal Thread) Must be used with M6063 actuator.
V5442N1031 1 1/4 in. DN32 Rotary 18.7 Cv 16 kvs NPT (Internal Thread) Must be used with M6063 actuator.

222 customer.honeywell.com 70-6910


Residential Heating Valves and Actuators
M6063 Rotary Actuator

Controls
Home
The Corona series of M6063 Actuator and V5442 Compact Rotary
Valves provide integrated mixing of boiler supply, boiler return,
loop supply, and loop return water in hydronic heating systems.
The M6063 actuator enables automatic mixing operation when
used with an AQ675A Aquatrol Outdoor Temperature
Compensator, or T6984 proportional room thermostat.
• 24 Vac floating input for automatic control.

Indoor Air Quality


• Single screw attachment to V5442 valve body.
• Multi-poise mounting.
• Color-coded position indicator.
• Manual valve operator.
• Auxiliary end switch for cascade control outputs.
• Sealed assembly; flylead electrical connections.

Dimensions in inches (millimeters) Distance for installation

Combustion Controls
Residential
14 (350) MINIMUM

11-13/16
(300)
1-13/16
(47)

Hydronic Controls
3-3/16 (81) M18264
2-3/4 (69)
4 (101)
M18265

Timing: 100 seconds for 90 degrees (full) stroke Enclosure Rating: Double insulated. IP44 according to 60529
Electrical Connections: Color-coded 40 in. (1 meter) cable Standard (exceeds NEMA 3).

Controls
Water
Voltage: 24V Aux Switch Ratings:
Frequency: 60 Hz; 50 Hz 24 Vac, 3A, 24 VA pilot duty, Class 2, normally closed, Gray cable.
Power Supply Rating: 3 VA, SDPT, or SP3T (tri-state) for proportional S1 (black/gray pair) opens at left (CCW) end stop.
control. S2 (brown/pink pair) opens at right (CW) end stop.
Torque Rating: 60 lb-in. Manual declutch (7 Nm Manual declutch) Operating Humidity Range (% RH): Less than 90% RH, non-
Cable: Blue=Common; Brown=Clockwise rotation; Black=Counter- condensing
clockwise rotation Ambient Temperature Range: 32 F to 140 F (0 C to 60 C)

Building Automation
Shipping Temperature Range: -40 F to +140 F (-40 C to +60 C)

Control
Product Number Controller Compatibility Signal Comments Used With
M6063A4007 PI or PID tri-state control signal for proportional control 24 Vac Cross Reference: M6063 functionally V5442 Four-way
action, such as supplied by AQ675 Outdoor Temperature Floating replaces Centra VRK10-24 valve actuator mixing valve
Compensator, W964F reset controller, or T6984 floating when used with V5442 valve body.
commercial thermostat.

Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 223
Residential Heating Valves and Actuators
VC Series Valves
Control central heating and/or cooling systems, fan coil systems,
radiators and convectors. Depending on the model selected, it can
be controlled by either a low or line voltage SPST or SPDT or
floating controller such as a room thermostat, Aquastat control, or
flow switch.
• Two-way or three-way valves.
• Minimal actuator power consumption.
• Double insulated actuator.
• Quick-connect or one-meter cable electrical connections available.
• Safe for use with potable water.
• Quick and easy replacement of moving parts.
• Actuator head installation does not require draining the system.
• On/Off models with six second nominal timing (floating/modulating
models available with 120 second timing).
Dimensions, Approximate: 3 9/16 in high x 2 3/4 in wide x 3 3/4 in Power Supply Rating: 6 VA, SPDT, or SP3T (tri-state) for proportional
long (111 mm high x 68 mm wide x 89 mm long) control.
Coupling Controller: Integral Differential (close-off) Pressure Rating: 60 psi (4 Bar)
Aux Switch Ratings: 24 Vac, 2.2A pilot duty, Class 2, SPDT Static Pressure Rating: 300 psi (20 Bar)
Timing: 120 sec Median Temperature Range: 34 F to 203 F (1 C to 95 C)
Control Signal: 24 Vac Floating Ambient Temperature Range: 32 F to 140 F (0 C to 60 C)
Electrical Connections: Color-coded 40 in. (1 meter) cable Shipping Temperature Range: -40 F to +150 F (-40 C to +65 C)
Voltage: 24V
Materials
Frequency: 60 Hz; 50 Hz (Body): Bronze

Pipe Size Capacity Flow


Body Charac- Pipe
Product Number Controller Compatibility Pattern (inch) (DN) (Cv) (Kvs) teristic Connection Comments
VC6831AA1111 Two-way 1/2 in. DN15 3.2 Cv 2.7 kvs Linear Sweat Use with max. 50%
glycol in water solution
VC6831AM1111 PI or PID tri-state control Two-way 3/4 in. DN20 4.6 Cv 3.9 kvs Linear Sweat Use with max. 50%
signal for proportional control glycol in water solution
action, such as supplied by
VC6831ML6111 AQ675 Outdoor Temperature Three-way 3/4 in. DN20 5.9 Cv 5.1 kvs Linear Sweat Use with max. 50%
Compensator, W964F reset glycol in water solution
controller, or T6984 floating
VC6831MS6111 commercial thermostat. Three-way 1 in. DN25 6.6 Cv 5.7 kvs Linear Sweat Use with max. 50%
glycol in water solution
VC6831ZZ11 Two-way — — — — Linear — Actuator only
VC8715AM1000 Two-way 3/4 in. — 5.8 Cv 5.0 kvs Quick Open Sweat Use with max. 50%
glycol in water solution
VC8715AS1000 24V SPST, Series 80 Two-way 1 in. DN25 7.0 Cv 6 kvs Quick Open Sweat Use with max. 50%
glycol in water solution
VC8715ZZ11 Two-way — — — — Quick Open — Actuator only

224 customer.honeywell.com 70-6910


Motorized Zone Valves
V4043 Line Voltage Zone Valves

Controls
Home
Indoor Air Quality
Flare Connection Sweat Connection Sweat Connection NPT Connection

Two way on-off line voltage valves consist of an actuator motor • Compact construction for easy installation.
and valve assembly for controlling the flow of hot or chilled water. • Complete powerhead may be removed or replaced without breaking

Combustion Controls
• Manual opener (on all models, except straight-through, normally plumbing line connections or draining the system.

Residential
open valves) for valve operation on power failure; valve returns to • Motor may be replaced without removing the valve body or draining
automatic position when power is restored. the system.
• All models may be installed without disassembling the valve. • Suitable for heating and cooling applications.
Application: Hydronic Control Comments: Use this valve in closed loop hydronic systems that do not
Type: 2 position contain dissolved oxygen in system water, such as fresh water from
Body Pattern: Two-way, Straight-through frequent source of makeup water.
Frequency: 60 Hz Valve designed for cycling (not constantly powered on) applications.
Power Consumption: 9.6 VA

Hydronic Controls
Approvals:
Nominal Timing (sec, min): 15 sec Underwriters Laboratories, Inc. UL Component Listed: File MH11826
Electrical Connections: 18 in. leads (457 mm leads) Vol. 1
Static Pressure: 125 psi (862 kPa)
Fluid Temperature Range: 40 F to 200 F (5 C to 93 C) Replacement Parts:
Maximum Ambient Temperature: 125 F (52 C) 802360LA 120V, 60 Hz Replacement motor for V4043, V4044 Zone
Valves
Materials
(Body): Brass 802360MA 208V, 60 Hz Replacement motor for V4043, V4044 Zone
(Stem): Stainless Steel Valves
(Seat): Brass 802360NA 220V/50 Hz; 240V/60 Hz Replacement motor for V4043,
(Packing O-Ring): EPDM rubber V4044 Zone Valves

Controls
(Ball Plug): Buna-N (NBR) Rubber Ball

Water
Maximum Close-
Pipe Size Capacity Connec- off Pressure
tion De-energized Current Manual
Product Number (inch) (DN) (Cv) (Kv) Type (psi) (kPa) Position Valve Action Voltage Draw (A) Opener
V4043A1002 1/2 in. DN15 3.5 Cv 3 Kv Flare 20 psi 138 kPa Normally Closed Spring return to 120 Vac 0.08A Yes

Building Automation
close
V4043A1010 1/2 in. DN15 3.5 Cv 3 Kv Sweat 20 psi 138 kPa Normally Closed Spring return to 120 Vac 0.08A Yes
close
V4043A1028 1/2 in. DN15 3.5 Cv 3 Kv Flare 20 psi 138 kPa Normally Closed Spring return to 208 Vac 0.04A Yes
close
V4043A1044 1/2 in. DN15 3.5 Cv 3 Kv Flare 20 psi 138 kPa Normally Closed Spring return to 240 Vac 0.04A Yes
close
V4043A1051 1/2 in. DN15 3.5 Cv 3 Kv Sweat 20 psi 138 kPa Normally Closed Spring return to 240 Vac 0.04A Yes
close

Components
Commercial
V4043A1184 1/2 in. DN15 1 Cv 0.9 Kv Sweat 50 psi 345 kPa Normally Closed Spring return to 120 Vac 0.08A Yes
close
V4043A1259 3/4 in. DN20 8 Cv 6.9 Kv Sweat 8 psi 55 kPa Normally Closed Spring return to 120 Vac 0.08A Yes
close
V4043A1317 1 in. DN25 8 Cv 6.9 Kv Sweat 8 psi 55 kPa Normally Closed Spring return to 120 Vac 0.08A Yes
close
V4043A1689 1/2 in. DN15 3.5 Cv 3 Kv NPT 20 psi 138 kPa Normally Closed Spring return to 120 Vac 0.08A Yes
Pneumatic Controls

close
V4043A1697 1 in. DN25 10 Cv 8.6 Kv NPT 6.5 psi 45 kPa Normally Closed Spring return to 120 Vac 0.08A Yes
close
V4043A1705 3/4 in. DN20 3.5 Cv 3 Kv NPT 20 psi 138 kPa Normally Closed Spring return to 120 Vac 0.08A Yes
close
V4043B1000 1/2 in. DN15 3.5 Cv 3 Kv Flare 20 psi 138 kPa Normally Open Spring return to 120 Vac 0.08A No
open
Industrial Combustion

V4043B1018 1/2 in. DN15 3.5 Cv 3 Kv Sweat 20 psi 138 kPa Normally Open Spring return to 120 Vac 0.08A No
open
Controls

V4043B1059 1/2 in. DN15 3.5 Cv 3 Kv Sweat 20 psi 138 kPa Normally Open Spring return to 240 Vac 0.04A No
open

70-6910 225
Motorized Zone Valves
Dimensions in inches (millimeters)

V4043, V8043 SWEAT COPPER CONNECTION MODELS 6


V4044, V8044 SWEAT COPPER CONNECTION MODELS

5
1 3-1/2 (89)
1
7/8 DIA. 2-3/8 1-3/4 1-3/4 2-3/8 1-3/4 1-3/4
(22) (60) (44) (44) (60) (44) (44)

8
8
5-1/4 5-1/4
1-1/2 (133) (133)
3/8 3/8
(38) AUTO MAN OPEN AUTO MAN OPEN
(10) (10)

4 3 2
IN A B OUT A B

7
1-7/8 1-11/16 1-1/2
(48) (43) (38)
7 AB
15/32 1-9/16
(12) (40) 2
3-1/8 1-9/16
(79) (40) 2
1-3/4 3-1/8
(44) 3
(79)
1-3/4
3-1/2 (44)
(89) 3
1-7/8 3-1/2
(47) 4 (89)
1-7/8
3-11/16 (47) 4
(94)
3-11/16
(94)
INLET

6 V4044, V8044 FLARE-FITTING MODELS


V4043, V8043 FLARE-FITTING MODELS

1 2-3/8 1-3/4 1-3/4


3-1/2 (89) (60) 1 (44) (44)
7/8 DIA. 2-3/8 (60)
(22) 1-3/4 1-3/4
(44) (44)

7 8
5-1/4 5-1/4 3/8 3-1/8
(133) MAN OPEN (133) (10) (79)
1-1/2 3-1/8 AUTO
(38) 3/8
AUTO MAN OPEN (79)
(10)

A B

IN A B OUT
7 2-1/4
7
(57)
15/32 7/8 AB
(12) (22)
2-11/32 2-11/32
(59) (59)

2-11/32 2-11/32
(59) (59)
V8043 INVERTED FLARE MODELS
INLET
1 HEIGHT NEEDED TO REMOVE COVER.

2 DIMENSIONS FOR 1/2 IN. COPPER TUBING.

IN OUT 3 DIMENSIONS FOR 3/4 IN COPPER TUBING.

4 DIMENSIONS FOR 1 IN. COPPER TUBING.

1-13/16 5 4-7/8 IN. (124) MAX ON V8034F WITH TERMINAL BOARD ENCLOSURE.
(46)
6 V4034B AND V8043B VALVES THAT ARE NORMALLY OPEN IN THE
3-5/8 (92)
DE-ENERGIZED POSITION HAVE NO MANUAL LEVER. THE VALVES
ALSO HAVE A REVERSED POWERHEAD WHERE THE LEADWIRES
EXIT THE POWERHEAD ABOVE THE B (OUTLET) PORT RATHER
THAN ABOVE THE A (INLET) PORT.
7
M10175 REFER TO MOUNTING INSTRUCTIONS.
8
OPENING FOR 1/2 IN. CONDUIT ON MANUAL LEVER SIDE FOR
V4043, V8043; OPENING ON OPPOSITE SIDE FOR V4044, V8044.

226 customer.honeywell.com 70-6910


Motorized Zone Valves
V4043 Line Voltage Zone Valves for Steam

Controls
Home
Two way on-off line voltage valves consist of an actuator motor
and valve assembly for controlling the flow of low pressure steam.
• Manual opener (on all models, except straight-through, normally
open valves) for valve operation on power failure; valve returns to
automatic position when power is restored.
• All models may be installed without disassembling the valve.
• Compact construction for easy installation.

Indoor Air Quality


• Complete powerhead may be removed or replaced without breaking
plumbing line connections or draining the system.
• Motor may be replaced without removing the valve body or draining
the system.
• Suitable for heating applications.

Dimensions Diagram: See page 226 Materials

Combustion Controls
Application: Steam (low pressure) Control (Body): Brass
Type: 2 position (Stem): Stainless Steel

Residential
Body Pattern: Two-way, Straight-through (Seat): Brass
Valve Action: Spring return to close (Packing O-Ring): EPDM rubber
Frequency: 60 Hz (Ball Plug): EPDM Rubber Ball
Power Consumption: 9.6 VA Comments: For low pressure (15 psi) steam application
Nominal Timing (sec, min): 15 sec Approvals:
De-energized Position: Normally Closed Underwriters Laboratories, Inc. UL Component Listed: File MH11826
Electrical Connections: 18 in. leads (457 mm leads) Vol. 1
Static Pressure: 125 psi (862 kPa)

Hydronic Controls
Fluid Temperature Range: 40 F to 240 F (5 C to 116 C) Replacement Parts:
Maximum Ambient Temperature: 125 F (52 C) 802360LA 120V, 60 Hz Replacement motor for V4043, V4044 Zone
Valves
802360MA 208V, 60 Hz Replacement motor for V4043, V4044 Zone
Valves
802360NA 220V/50 Hz; 240V/60 Hz Replacement motor for V4043,

Pipe Size Capacity Maximum Close-off Pressure


Connection Manual
Product Number (inch) (DN) (Cv) (Kv) Type (psi) (kPa) Voltage Opener

Controls
V4043E1003 1/2 in. DN15 3.5 Cv 3 Kv Sweat 20 psi 138 kPa 120 Vac Yes

Water
V4043E1011 1/2 in. DN15 3.5 Cv 3 Kv Sweat 20 psi 138 kPa 208 Vac Yes
V4043E1029 1/2 in. DN15 3.5 Cv 3 Kv Sweat 20 psi 138 kPa 240 Vac Yes

Building Automation
Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 227
Motorized Zone Valves
V4044 Line Voltage Diverting Valves
On-off and diverting line voltage valves consist of an actuator
motor and valve assembly for controlling the flow of hot or chilled
water.
• Manual opener (on all models, except straight-through, normally
open valves) for valve operation on power failure; valve returns to
automatic position when power is restored.
• All models may be installed without disassembling the valve.
• Compact construction for easy installation.
• Complete powerhead may be removed or replaced without breaking
plumbing line connections or draining the system.
• Motor may be replaced without removing the valve body or draining
the system.
• Suitable for heating and cooling applications.

Dimensions Diagram: See page 226 Materials


Application: Hydronic Control (Body): Brass
Type: 2 position (Stem): Stainless Steel
Body Pattern: 3-Way, Diverting (Seat): Brass
Valve Action: Spring Return to port A (Packing O-Ring): EPDM rubber
Frequency: 60 Hz (Ball Plug): Buna-N (NBR) Rubber Ball
Power Consumption: 9.6 VA Comments: Use this valve in closed loop hydronic systems that do not
Nominal Timing (sec, min): 30 sec contain dissolved oxygen in system water, such as fresh water from
De-energized Position: Port A Normally Closed frequent source of makeup water.
Static Pressure: 125 psi (862 kPa) Valve designed for cycling (not constantly powered on) applications.
Fluid Temperature Range: 40 F to 200 F (5 C to 93 C) Approvals:
Maximum Ambient Temperature: 125 F (52 C) Underwriters Laboratories, Inc. UL Component Listed: File MH11826
Vol. 1
Replacement Parts:
802360LA 120V, 60 Hz Replacement motor for V4043, V4044 Zone Valves
802360MA 208V, 60 Hz Replacement motor for V4043, V4044 Zone Valves
802360NA 220V/50 Hz; 240V/60 Hz Replacement motor for V4043,
V4044 Zone Valves
802360QA 277V, 50/60 Hz Replacement motor for V4043, V4044 Zone
Valves

Maximum
Pipe Size Capacity Close-off Pressure
Connection Manual Electrical Additional
Product Number (inch) (DN) (Cv) (Kv) Type (psi) (kPa) Voltage Opener Connections Comments
V4044A1001 1/2 in. DN15 4 Cv 3.4 Kv Flare 20 psi 138 kPa 120 Vac Yes 18 in. leads (457 —
mm leads)
V4044A1019 1/2 in. DN15 4 Cv 3.4 Kv Sweat 20 psi 138 kPa 120 Vac Yes 18 in. leads (457 —
mm leads)
V4044A1035 1/2 in. DN15 4 Cv 3.4 Kv Sweat 20 psi 138 kPa 208 Vac Yes 18 in. leads (457 —
mm leads)
V4044A1043 1/2 in. DN15 4 Cv 3.4 Kv Flare 20 psi 138 kPa 240 Vac Yes 18 in. leads (457 —
mm leads)
V4044A1050 1/2 in. DN15 4 Cv 3.4 Kv Sweat 20 psi 138 kPa 240 Vac Yes 18 in. leads (457 —
mm leads)
V4044A1191 3/4 in. DN20 7.0 Cv 6 Kv Sweat 10 psi 69 kPa 120 Vac Yes 18 in. leads (457 —
mm leads)
V4044A1258 1/2 in. DN15 4 Cv 3.4 Kv Sweat 20 psi 138 kPa 277 Vac Yes 24 in. leads (610 —
mm leads)
V4044A1290 1/2 in. DN15 2.7Cv; 4 Cv 3.4 Kv Sweat 20 psi 138 kPa 120 Vac Yes 18 in. leads (457 Restricted
mm leads) by-pass
V4044B1009 1/2 in. DN15 4 Cv 3.4 Kv Flare 20 psi 138 kPa 120 Vac Yes 18 in. leads (457 —
mm leads)
V4044B1017 1/2 in. DN15 4 Cv 3.4 Kv Sweat 20 psi 138 kPa 120 Vac Yes 18 in. leads (457 —
mm leads)
V4044B1314 3/4 in. DN20 7.0 Cv 6 Kv Sweat 10 psi 69 kPa 120 Vac Yes 18 in. leads (457 —
mm leads)

228 customer.honeywell.com 70-6910


Motorized Zone Valves
V8043 Low Voltage Normally Closed Zone Valves

Controls
Home
Indoor Air Quality
V8043 Flare V8043A Sweat V8043E Flare V8043E Sweat V8043A
Inverted Flare

Combustion Controls
Residential
Hydronic Controls
V8043A Sweat V8043A Sweat V8043F Sweat V8043F Sweat V8043F Sweat

Two-way on-off low voltage valves consist of an actuator and valve • Compact construction for easy installation.
assembly for controlling the flow of hot water. • Complete powerhead may be removed or replaced without breaking
• Manual opener (on all models, except straight-through, normally plumbing line connections or draining the system.
open valves) for valve operation on power failure; valve returns to • Actuator motor may be replaced without removing the valve body or
automatic position when power is restored. draining the system.
• All models may be installed without disassembling the valve.
Dimensions Diagram: See page 226

Controls
Application: Hydronic Control Materials

Water
Type: 2 position (Body): Brass
Body Pattern: Two-way, Straight-through (Stem): Stainless Steel
Valve Action: Spring return to close (Seat): Brass
Voltage: 24 Vac (Packing O-Ring): EPDM rubber
Frequency: 50 Hz; 60 Hz (Ball Plug): Buna-N (NBR) Rubber Ball
Power Consumption: 7.7 VA Approvals:
Nominal Timing (sec, min): 15 sec

Building Automation
Underwriters Laboratories, Inc. UL Component Listed: File MH11826
De-energized Position: Normally Closed Vol. 1
Electrical Connections: 18 in. leads (457 mm leads)
Static Pressure: 125 psi (862 kPa) Replacement Parts:
Fluid Temperature Range: 50 F to 200 F (10 C to 93 C) 802360JA 24V, 50/60 Hz Replacement motor for V8043, V8044 Zone
Maximum Ambient Temperature: 125 F (52 C) Valves
Comments: Use this valve in closed loop hydronic systems that do not 802360UA 24V, 50/60 Hz Replacement motor for steam and heating
contain dissolved oxygen in system water, such as fresh water from Replacement Parts:
frequent source of makeup water.
Valve designed for cycling (not constantly powered on) applications.

Components
Commercial
Maximum
Close-off
Pipe Size Capacity Pressure
Connection Auxiliary Manual
Product Number (inch) DN (Cv) (Kv) Type End Switch (psi) (kPa) Opener Electrical Connections
V8043A1003 1/2 in. DN15 3.5 Cv 3 Kv Flare — 20 psi 138 kPa Yes 18 in. leads (457 mm leads)
V8043A1011 1/2 in. DN15 3.5 Cv 3 Kv Sweat — 20 psi 138 kPa Yes 18 in. leads (457 mm leads)
Pneumatic Controls

V8043A1029 3/4 in. DN20 3.5 Cv 3 Kv Sweat — 20 psi 138 kPa Yes 18 in. leads (457 mm leads)
V8043A1037 1 in. DN25 3.5 Cv 3 Kv Sweat — 20 psi 138 kPa Yes 18 in. leads (457 mm leads)
* V8043A1193 1/2 in. DN15 3.5 Cv 3 Kv Inverted Flare — 20 psi 138 kPa Yes 18 in. leads (457 mm leads)
V8043A1227 1/2 in. DN15 3.5 Cv 3 Kv NPT — 20 psi 138 kPa Yes 18 in. leads (457 mm leads)
* V8043E1004 1/2 in. DN15 3.5 Cv 3 Kv Sweat SPST 20 psi 138 kPa Yes 18 in. leads (457 mm leads)
* V8043E1012 3/4 in. DN20 3.5 Cv 3 Kv Sweat SPST 20 psi 138 kPa Yes 18 in. leads (457 mm leads)
Industrial Combustion

* V8043E1020 1 in. DN25 3.5 Cv 3 Kv Sweat SPST 20 psi 138 kPa Yes 18 in. leads (457 mm leads)
V8043E1061 3/4 in. DN20 8 Cv 6.9 Kv Sweat SPST 8 psi 55 kPa Yes 18 in. leads (457 mm leads)
Controls

* TRADELINE models • SUPER TRADELINE models

70-6910 229
Motorized Zone Valves
Maximum
Close-off
Pipe Size Capacity Pressure
Connection Auxiliary Manual
Product Number (inch) DN (Cv) (Kv) Type End Switch (psi) (kPa) Opener Electrical Connections
V8043E1079 1 in. DN25 8 Cv 6.9 Kv Sweat SPST 8 psi 55 kPa Yes 18 in. leads (457 mm leads)
* V8043E1129 1/2 in. DN15 3.5 Cv 3 Kv Inverted Flare SPST 20 psi 138 kPa Yes 18 in. leads (457 mm leads)
V8043E1137 1 in. DN25 10 Cv 8.6 Kv NPT SPST 6.5 psi 45 kPa Yes 18 in. leads (457 mm leads)
V8043E1145 3/4 in. DN20 3.5 Cv 3 Kv NPT SPST 20 psi 138 kPa Yes 18 in. leads (457 mm leads)
* V8043F1028 1/2 in. DN15 3.5 Cv 3 Kv Sweat SPST 20 psi 138 kPa Yes screw terminal block
* V8043F1036 3/4 in. DN20 3.5 Cv 3 Kv Sweat SPST 20 psi 138 kPa Yes screw terminal block
* V8043F1051 1 in. DN25 3.5 Cv 3 Kv Sweat SPST 20 psi 138 kPa Yes screw terminal block
V8043F1093 3/4 in. DN20 8 Cv 6.9 Kv Sweat SPST 8 psi 55 kPa Yes screw terminal block
V8043F1101 1 in. DN25 8 Cv 6.9 Kv Sweat SPST 8 psi 55 kPa Yes screw terminal block
* TRADELINE models • SUPER TRADELINE models

V8043 Low Voltage Normally Open Valves For Steam


On-off and two way low voltage valves consist of an actuator and
valve assembly for controlling the flow low pressure steam.
• All models may be installed without disassembling the valve.
• Compact construction for easy installation.
• Complete powerhead may be removed or replaced without breaking
plumbing line connections or draining the system.
• Actuator motor may be replaced without removing the valve body or
draining the system.
• Suitable for use 15 psi low pressure steam application.

Dimensions Diagram: See page 226 Materials


Application: Steam (low pressure) Control (Body): Brass
Type: 2 position (Stem): Stainless Steel
Body Pattern: Two-way, Straight-through (Seat): Brass
Valve Action: Spring return to open (Packing O-Ring): EPDM rubber
Voltage: 24 Vac (Ball Plug): EPDM Rubber Ball
Frequency: 50 Hz; 60 Hz Comments: For low pressure (15 psi) steam application
Power Consumption: 7.7 VA Approvals:
Nominal Timing (sec, min): 15 sec Underwriters Laboratories, Inc. UL Component Listed: File MH11826
De-energized Position: Normally Open Vol. 1
Electrical Connections: 18 in. leads (457 mm leads)
Static Pressure: 125 psi (862 kPa) Replacement Parts:
Fluid Temperature Range: 50 F to 240 F (10 C to 116 C) 802360UA 24V, 50/60 Hz Replacement motor for steam and heating
Maximum Ambient Temperature: 125 F (52 C) Zone Valves

Pipe Size Capacity Maximum Close-off Pressure


Connection Manual
Product Number (inch) DN (Cv) (Kv) Type (psi) (kPa) Voltage Opener
V8043J1003 1/2 in. DN15 3.5 Cv 3 Kv Sweat 20 psi 138 kPa 24 Vac No
V8043J1029 1/2 in. DN15 3.5 Cv 3 Kv NPT 20 psi 138 kPa 24 Vac No
V8043J1037 3/4 in. DN20 3.5 Cv 3 Kv NPT 20 psi 138 kPa 24 Vac No

230 customer.honeywell.com 70-6910


Motorized Zone Valves
V8043 Low Voltage Normally Open Zone Valves

Controls
Home
On-off and two-way low voltage valves consist of an actuator and
valve assembly for controlling the flow of hot water.
• All models may be installed without disassembling the valve.
• Compact construction for easy installation.
• Complete powerhead may be removed or replaced without breaking
plumbing line connections or draining the system.
• Actuator motor may be replaced without removing the valve body or

Indoor Air Quality


draining the system.
• No Manual opener

Combustion Controls
Residential
Dimensions Diagram: See page 226 Materials
Application: Hydronic Control (Body): Brass
Type: 2 position (Stem): Stainless Steel
Body Pattern: Two-way, Straight-through (Seat): Brass
Valve Action: Spring return to open (Packing O-Ring): EPDM rubber
Voltage: 24 Vac (Ball Plug): Buna-N (NBR) Rubber Ball
Power Consumption: 7.7 VA Approvals:

Hydronic Controls
Nominal Timing (sec, min): 15 sec Underwriters Laboratories, Inc. UL Component Listed: File MH11826
De-energized Position: Normally Open Vol. 1
Electrical Connections: 18 in. leads (457 mm leads)
Static Pressure: 125 psi (862 kPa) Replacement Parts:
Fluid Temperature Range: 40 F to 200 F (5 C to 93 C) 802360JA 24V, 50/60 Hz Replacement motor for V8043, V8044 Zone
Maximum Ambient Temperature: 125 F (52 C) Valves
Comments: Use this valve in closed loop hydronic systems that do not 802360UA 24V, 50/60 Hz Replacement motor for steam and heating
contain dissolved oxygen in system water, such as fresh water from Zone Valves
frequent source of makeup water.
Valve designed for cycling (not constantly powered on) applications.

Controls
Water
Maximum Close-off
Pipe Size Capacity Pressure
Connection Manual
Product Number (inch) DN (Cv) (Kv) Type (psi) (kPa) Frequency Opener
V8043B1019 1/2 in. DN15 3.5 Cv 3 Kv Sweat 20 psi 138 kPa 60 Hz No
V8043B1027 3/4 in. DN20 3.5 Cv 3 Kv Sweat 20 psi 138 kPa 60 Hz No

Building Automation
V8043B1076 3/4 in. DN20 3.5 Cv 3 Kv NPT 20 psi 138 kPa 50 Hz; 60 Hz No

Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 231
Motorized Zone Valves
V8043 Series 5000 QuickFit® Zone Valves
Two-way on-off low voltage valves consist of an actuator and valve
assembly for controlling the flow of hot water.
• All models may be installed without disassembling the valve.
• Compact construction for easy installation.
• Manual opener (on all models, except straight-through, normally
open valves) for valve operation on power failure; valve returns to
automatic position when power is restored.
• Complete powerhead may be removed or replaced without breaking
plumbing line connections or draining the system.
• "Quick Fit" pushbutton powerhead makes it easy to remove for
service.
• Series 5000 replacement powerhead is backward compatible with
series 1000 zone valves.
• Innovative motor technology offers silent operation, water hammer
resist and longer life.

Dimensions in inches (millimeters) Application: Hydronic Control


Type: 2 position
V8043 SWEAT QUICKFIT ® CONNECTION MODELS 6
Body Pattern: Two-way, Straight-through
Valve Action: Spring return to close
7/8 DIA.
(22)
5 Voltage: 24 Vac
1
2-3/8
3-1/2 (89)
1-3/4
Frequency: 60 Hz
1-3/4
7
(60) 5-3/4 (44) (44) Power Consumption: 7.2 VA
(146) De-energized Position: Normally Closed
Static Pressure: 300 psi (2068 kPa)
Fluid Temperature Range: 200 F Max. (93 C Max.)
Maximum Ambient Temperature: 125 F (52 C)
1-1/2 3/8
(38) AUTO MAN OPEN (10) Materials
(Body): Brass
(Stem): Stainless Steel
IN A B OUT
(Seat): Brass
(Packing O-Ring): EPDM rubber
(Ball Plug): Buna-N (NBR) Rubber Ball
15/32 1-9/16
Comments: Use this valve in closed loop hydronic systems that do not
(12) (40) 2 contain dissolved oxygen in system water, such as fresh water from
3-1/8 frequent source of makeup water.
(79) Valve designed for cycling (not constantly powered on) applications.
1-3/4
3
(44) Approvals:
1 HEIGHT NEEDED TO REMOVE 3-1/2 Canadian Standards Association: CSA C/US
(89)
COVER.
1-7/8
Underwriters Laboratories, Inc. CSA C/US
(47) 4
2 DIMENSIONS FOR 1/2 IN.
COPPER TUBING. 3-11/16 (94)

3 DIMENSIONS FOR 3/4 IN COPPER TUBING.

4 DIMENSIONS FOR 1 IN. COPPER TUBING.

5 4-7/8 IN. (124) MAX ON V8034F WITH TERMINAL BOARD ENCLOSURE.

6 V8043B VALVES THAT ARE NORMALLY OPEN IN THE DE-ENERGIZED


POSITION HAVE NO MANUAL LEVER. THE VALVES ALSO HAVE A
REVERSED POWERHEAD WHERE THE LEADWIRES EXIT THE
POWERHEAD ABOVE THE B (OUTLET) PORT RATHER THAN ABOVE
THE A (INLET) PORT.

7 OPENING FOR 1/2 IN. CONDUIT ON MANUAL LEVER SIDE FOR V8043
M23257

Maximum Close-off
Pipe Size Capacity Auxiliary Pressure
Connection End Manual
Product Number (inch) DN (Cv) (Kv) Type Switch (psi) (kPa) Opener Electrical Connections
V8043A5011 1/2 in. DN15 3.5 Cv 3 Kv Sweat — 20 psi 138 kPa Yes 18 in. leads (457 mm leads)
V8043A5029 3/4 in. DN20 3.5 Cv 3 Kv Sweat — 20 psi 138 kPa Yes 18 in. leads (457 mm leads)
V8043E5004 1/2 in. DN15 3.5 Cv 3 Kv Sweat SPST 20 psi 138 kPa Yes 18 in. leads (457 mm leads)
V8043E5012 3/4 in. DN20 3.5 Cv 3 Kv Sweat SPST 20 psi 138 kPa Yes 18 in. leads (457 mm leads)
V8043E5020 1 in. DN25 3.5 Cv 3 Kv Sweat SPST 20 psi 138 kPa Yes 18 in. leads (457 mm leads)
V8043E5061 3/4 in. DN20 8 Cv 6.9 Kv Sweat SPST 8 psi 55 kPa Yes 18 in. leads (457 mm leads)
V8043E5079 1 in. DN25 8 Cv 6.9 Kv Sweat SPST 8 psi 55 kPa Yes 18 in. leads (457 mm leads)
V8043F5036 3/4 in. DN20 3.5 Cv 3 Kv Sweat SPST 20 psi 138 kPa Yes screw terminal block
V8043F5051 1 in. DN25 3.5 Cv 3 Kv Sweat SPST 20 psi 138 kPa Yes screw terminal block
V8043F5093 3/4 in. DN20 8 Cv 6.9 Kv Sweat SPST 8 psi 55 kPa Yes screw terminal block

232 customer.honeywell.com 70-6910


Motorized Zone Valves
V8044 Low Voltage Diverting Valves

Controls
Home
Indoor Air Quality
Flare Connection NPT Connection Sweat Connection Sweat Connection Sweat Connection

Combustion Controls
Residential
On-off and diverting low voltage valves consist of an actuator and • Compact construction for easy installation.
valve assembly for controlling the flow of hot water. • Complete powerhead may be removed or replaced without breaking
• Manual opener (on all models, except straight-through, normally plumbing line connections or draining the system.
open valves) for valve operation on power failure; valve returns to • Actuator motor may be replaced without removing the valve body or
automatic position when power is restored. draining the system.
• All models may be installed without disassembling the valve.

Dimensions Diagram: See page 226 Materials


Application: Hydronic Control (Body): Brass

Hydronic Controls
Type: 2 position (Stem): Stainless Steel
Body Pattern: 3-Way, Diverting (Seat): Brass
Valve Action: Spring Return (Packing O-Ring): EPDM rubber
Voltage: 24 Vac (Ball Plug): Buna-N (NBR) Rubber Ball
Frequency: 60 Hz; 50 Hz Approvals:
Power Consumption: 7.7 VA Underwriters Laboratories, Inc. UL Component Listed: File MH11826
Nominal Timing (sec, min): 30 sec Vol. 1
De-energized Position: Port A Normally Closed
Electrical Connections: 18 in. leads (457 mm leads) Replacement Parts:
Static Pressure: 125 psi (862 kPa) 802360JA 24V, 50/60 Hz Replacement motor for V8043, V8044 Zone
Fluid Temperature Range: 40 F to 200 F (5 C to 93 C) Valves

Controls
Water
Maximum Ambient Temperature: 125 F (52 C) 802360UA 24V, 50/60 Hz Replacement motor for steam and heating
Comments: Use this valve in closed loop hydronic systems that do not Zone Valves
contain dissolved oxygen in system water, such as fresh water from
frequent source of makeup water.
Valve designed for cycling (not constantly powered on) applications.

Building Automation
Maximum Close-
Pipe Size Capacity Auxiliary off Pressure
Connection End Manual
Product Number (inch) DN (Cv) (Kv) Type Switch (psi) (kPa) Includes Opener
V8044A1002 1/2 in. DN15 4 Cv 3.4 Kv Flare — 20 psi 138 kPa — Yes
V8044A1010 1/2 in. DN15 4 Cv 3.4 Kv Sweat — 20 psi 138 kPa — Yes
V8044A1044 3/4 in. DN20 7.0 Cv 6 Kv Sweat — 10 psi 69 kPa — Yes
V8044A1051 1/2 in. DN15 4 Cv 3.4 Kv Sweat — 20 psi 138 kPa Restricted 2.5 Cv bypass port. Yes
V8044A1135 1/2 in. DN15 4 Cv 3.4 Kv NPT — 20 psi 138 kPa — Yes

Components
Commercial
V8044A1143 3/4 in. DN20 4 Cv 3.4 Kv NPT — 20 psi 138 kPa — Yes
V8044B1018 1/2 in. DN15 4 Cv 3.4 Kv Sweat — 20 psi 138 kPa Integral SPDT changeover Yes
Aquastat controller
V8044E1003 1/2 in. DN15 4 Cv 3.4 Kv Sweat SPST 20 psi 138 kPa — Yes
V8044E1011 3/4 in. DN20 7.0 Cv 6 Kv Sweat SPST 10 psi 69 kPa — Yes
Pneumatic Controls
Industrial Combustion
Controls

70-6910 233
Motorized Zone Valves
Y496 Zone Control Builder Packs

Contain devices necessary for temperature control of a single zone


in a hydronic heating system.
Product Number Y-Pack Includes
• Includes thermostat with special heat anticipator designed for best
performance when used with the VC8715AM1000 Valve. Y496A1074 V8043E1012, T822K1018
• Require 24 V power source.
Y496A1082 V8043E1004, T822K1018
Valve Dimensions Diagram: See page 226 Y496A1090 V8043E1061, T822K1018
Pipe Connection: Sweat
Y496B1024 V8043E1012, T87K1007
Body Pattern: Two-way
Valve Action: Spring return to close Y496B1040 V8043F1036, T87K1007
Thermostat Electrical Rating: 24 V, 50/60 Hz
Y496E1005 V8043A1029, TH5110D1006
Thermostat Color: Premier White®
Comments: See valve and thermostat for more details. Y496E1013 V8043E1004, TH5110D1006
Includes: (Y496B1024 and Y496B1040 only) 104456B Wallplate Y496E1021 V8043E1012, TH5110D1006
Approvals: Y896C1016 VC8715AM1000, T8400B1018
Underwriters Laboratories, Inc. UL Listed: Models V8043A,B,E,J &
V8044A,B,E; UL Component Recognized: V8043F

Thermostat Valve
Maximum
Temperature Pipe Close-off
Anticipator Adj. Range Capacity Size Pressure Electrical
Aux Switch Connec- Electrical
Product Number Application Heating Cooling (F) (C) Current (Cv) (Kv) (inch) (psi) (kPa) Ratings tions Rating
* Y496A1074 Single Stage 0.18 to — 55 to 95 F — 3.5 Cv 3 Kv 3/4 in. 20 psi 138 kPa 50 VA pilot duty 18 in. leads 24 Vac,
Heating Only 1.0 A 13 to 35 C @ 24 V 50/60 Hz
* Y496A1082 — — 3.5 Cv 3 Kv 1/2 in. 20 psi 138 kPa 4.4 A running 18 in. leads
* Y496A1090 — — 8 Cv 6.9 Kv 3/4 in. 8 psi 55 kPa @ 120 V 18 in. leads
* Y496B1024 Single Stage 0.1 to 0.0 to 40 to 90 4 to 32 C — 3.5 Cv 3 Kv 3/4 in. 20 psi 138 kPa 18 in. leads
Heating/ 1.2 A 1.5 A F
* Y496B1040 Cooling — 3.5 Cv 3 Kv 3/4 in. 20 psi 138 kPa Screw
Terminal Block
* Y496E1005 — — Heat: Heat: Cooling: 3.5 Cv 3 Kv 3/4 in. 20 psi 138 kPa — 18 in. leads
40 F to 4.5 C to 1.0 A
* Y496E1013 — — 90 F; 32 C; running; 3.5 Cv 3 Kv 1/2 in. 20 psi 138 kPa 50 VA pilot duty 18 in. leads
Cool: Cool: Heating: @ 24 V
* Y496E1021 — — 3.5 Cv 3 Kv 3/4 in. 20 psi 138 kPa 4.4 A running 18 in. leads
50 F to 10 C to 1.0 A
99 F 37 C running; @ 120 V
Fan:
0.5 A
running
* Y896C1016 Single Stage — — 40 to 99 4 to 39 C — 5.8 Cv 5 Kv 3/4 in. 60 psi 97 kPa Screw 24 Vac,
Heating Only F Terminal Block 60 Hz
* TRADELINE models • SUPER TRADELINE models

234 customer.honeywell.com 70-6910


Motorized Zone Valves
Replacement Parts

Controls
Home
Product Number Description Includes
40003918-006 Adaptor kit for V4043, V8043, 2-way hydronic valves Adapter plate, ball and shaft assembly, large O-ring and four mounting screws.
40003918-007 Adaptor kit for V4044, V8044, 3-way diverting valves Adapter plate, ball and shaft assembly, large O-ring and four mounting screws.
40003918-008 Adaptor kit for V4043E, J, V8043J, low pressure steam Adapter plate, ball and shaft assembly, large O-ring and four mounting screws.

Indoor Air Quality


valves

Zone Valve Replacement Parts


Used With
Product Number Description Voltage Frequency Valve Includes

Combustion Controls
132184B Replacement ball plug for V8043, V8044, — — — —
V4043, V4044 valves (not for steam)

Residential
272708A 1/2 in. inverted flare to 1/2 in. sweat — — — —
adapter
272708B 1/2 in. inverted flare to 3/4 in. sweat — — — —
adapter
802360JA 24V, 50/60Hz replacement motor for 24V 50 Hz; 60 Hz V8043A,E,F Motor mounting screw
V8043 zone valves and lead connectors

Hydronic Controls
802360LA 120V, 60Hz replacement motor for 120V 60 Hz V4043, Motor mounting screw
V4043, V4044 zone valves V4044 and lead connectors
802360MA 208, 60Hz replacement motor for V4043, 208V 60 Hz V4043, Motor mounting screw
V4044 zone valves. V4044 and lead connectors
802360NA 220V/50Hz; 240V/60Hz replacement 220V/50 Hz 50 Hz; 60 Hz V4043, Motor mounting screw
motor for V4043, V4044 zone valves. 240V/60 Hz V4044 and lead connectors
802360QA 277V, 60Hz replacement motor for 277V 60 Hz V4043, Motor mounting screw
V4043, V4044 zone valves V4044 and lead connectors
802360UA 24V, 50/60 Hz Replacement motor for 24V 50 Hz; 60 Hz V8043J Motor mounting screw
steam and heating Zone Valves and lead connectors

Controls
Water
803867A Conduit case and cover for use with the — — V8043F Case and cover
V8043F when the end switch is used in
line voltage application.

Building Automation
Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 235
Motorized Zone Valves
Zone Valves Replacement Heads
Maximum
Ambient
Electrical Temperature Used
Connection Used With With
Product Number Description Location Voltage Frequency (F) (C) Valve Action Valve
40003916-021 24 Vac, 50/60 Hz Same side of 24 Vac 50 Hz; 60 Hz 125 F 52 C Spring return Two-way
Replacement head for V8043A manual lever to close
40003916-023 240 Vac, 50 Hz Replacement Same side of 240 Vac 50 Hz 125 F 52 C Spring return Two-way
head for V4043A, 240V, 50Hz manual lever to close
40003916-024 120 Vac, 60 Hz Replacement Same side of 120 Vac 60 Hz 125 F 52 C Spring return Two-way
head for V4043A manual lever to close
40003916-025 24 Vac, 50/60 Hz Same side of 24 Vac 50 Hz; 60 Hz 125 F 52 C Spring return Diverting
Replacement head with End manual lever to close "A"
Switch for V8044E port
40003916-026 24 Vac, 50/60 Hz Same side of 24 Vac 50 Hz; 60 Hz 125 F 52 C Spring return Two-way
Replacement head with End manual lever to close
Switch for V8044E
40003916-027 24 Vac, 50/60 Hz, N.O. Same side of 24 Vac 50 Hz; 60 Hz 125 F 52 C Spring return Two-way
Replacement head for V8043B manual lever to open
40003916-030 240 Vac, 60 Hz, N.O. Same side of 240 Vac 60 Hz 125 F 52 C Spring return Two-way
Replacement actuator for manual lever to open
V4043B
40003916-031 120 Vac, 60 Hz, N.O. Same side of 120 Vac 60 Hz 125 F 52 C Spring return Two-way
Replacement head for V4043B manual lever to open
40003916-032 24 Vac, 50/60 Hz On opposite 24 Vac 50 Hz; 60 Hz 125 F 52 C Spring return Diverting
Replacement head for V8044A side of to close "A"
manual lever port
40003916-035 220/240 Vac, 50/60 Hz On opposite 220 Vac; 50 Hz; 60 Hz 125 F 52 C Spring return Diverting
side of 240 Vac to close "A"
manual lever port
40003916-036 120 Vac, 60 Hz Replacement On opposite 120V 60 Hz 125 F 52 C Spring return Diverting
head for V4044 side of to close "A"
manual lever port
40003916-037 24 Vac, 50/60 Hz On opposite 24 Vac 50 Hz; 60 Hz 125 F 52 C Spring return Diverting
Replacement head for side of to close "A"
V8044B, With Aquastat Switch manual lever port
40003916-040 120 Vac, 60 Hz Replacement On opposite 120 Vac 60 Hz 125 F 52 C Spring return Diverting
head for V8044B, With side of to close "A"
Aquastat Switch manual lever port
40003916-041 120 Vac, 60 Hz Replacement Same side of 120 Vac 60 Hz 125 F 52 C Spring return Two-way
head for V4043E, Steam Valve manual lever to close
40003916-043 24 Vac, 50/60 Hz Same side of 24 Vac 50 Hz; 60 Hz 125 F 52 C Spring return Diverting
Replacement head with End manual lever to close "A"
Switch for V8044E port
40003916-044 24 Vac, 50/60 Hz Same side of 24 Vac 50 Hz; 60 Hz 125 F 52 C Spring return Diverting
Replacement head for manual lever to close "A"
V8044B, with Aquastat port
40003916-045 120 Vac, 60 Hz Replacement Same side of 120 Vac 60 Hz 125 F 52 C Spring return Diverting
head for V4044B, with manual lever to close "A"
Aquastat port
40003916-046 24 Vac, 50/60 Hz Same side of 24 Vac 50 Hz; 60 Hz 125 F 52 C Spring return Diverting
Replacement head for V8044A manual lever to close "A"
port
40003916-047 120 Vac, 60 Hz Replacement Same side of 120 Vac 60 Hz 125 F 52 C Spring return Diverting
head for V4044A, 120V, 60Hz, manual lever to close "A"
with 96 in. leads port
40003916-048 24 Vac, 50/60 Hz Same side of 24 Vac 50 Hz; 60 Hz 125 F 52 C Spring return Two-way
Replacement head for manual lever to close
V8043F, With End Switch
40003916-049 240V, 50 Hz Replacement — 240V 50 Hz 125 F 52 C Spring return Diverting
head for V4044 to close "A"
port

236 customer.honeywell.com 70-6910


Motorized Zone Valves

Controls
Maximum

Home
Ambient
Electrical Temperature Used
Connection Used With With
Product Number Description Location Voltage Frequency (F) (C) Valve Action Valve
40003916-521 24 Vac, 50/60 Hz Same side of 24 Vac 50 Hz; 60 Hz 125 F 52 C Spring return Two-way
Replacement head for V8043A manual lever to close
5000 series

Indoor Air Quality


40003916-526 24 Vac, 50/60 Hz Same side of 24 Vac 50 Hz; 60 Hz 125 F 52 C Spring return Two-way
Replacement head with End manual lever to close
Switch, for V8043E 5000
series

40003916-548 24 Vac, 50/60 Hz Same side of 24 Vac 50 Hz; 60 Hz 125 F 52 C Spring return Two-way
Replacement head for manual lever to close

Combustion Controls
V8043F, With End Switch

Residential
Hydronic Controls
Controls
Water
Building Automation
Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 237
Motorized Zone Valves
MZV Series Motorized Zone valves
• Two piece rack design to extend service life.
• Low power consumption, 8 valves, 40 VA transformer.
• External valve position indicator.
• Quiet operation, no water hammer.
• Built-in tamper resistant balancing valve for pre-balancing.
• High torque, constant speed synchronous motor.
• Cooler running, longer life motor.
• Operator can be replaced without draining system.
• Manual opening feature.
• Replaceable valve cartridge.
• Large adjustable flow, 1/2 in. 3/4 in. Cv 5.8; 1 in. 7.0 Cv; 1-1/4 in. Cv
7.0.
• Motor CSA recognized.
• 4 wire operator with auxiliary switch.
• 2 wire without switch, 24 in. leads.
• Compatible with programmable thermostats.
Honeywell MZV Series is the first linear zone valve with a built-in • Bronze casting; brass/stainless trim.
balancing plug that permits pre-balancing for each zone. • USA Patent Nos. 5,529,282; D369,650; 5,941,500; 6,032,924.
• Rack and pinion linear design. • UK Patent No. 2,052,382. 24 VAC, 60 Hz, 0.25 ampere.
• Fast acting, 15 seconds to open, 5 seconds to close. • 30 mm collar (valve/actuator interface)

Dimensions in inches (millimeters) Patented long life rack and pinion design with built-in balancing
valve

1 IN.

525

SIZE
3/4
B

A D E

DIMENSIONS (INCHES)
MZV SIZE
SERIES A B C D E
Application: Residential or Commercial Zoning for hot water heating or
524 1/2 IN. 3-5/16 1 4-13/16 11/16 1-5/8 chilled water air conditioning systems, fan coil units or indirect water
525 3/4 IN. 3-5/16 13/16 4-13/16 11/16 1-5/8 heater service.
526 3-13/16 1 4-13/16 13/16
Body Pattern: Two-way
1 IN. 1-5/8
Voltage: 24 Vac
527 1-1/4 IN. 3-13/16 1 4-13/16 13/16 1-5/8 Frequency: 60 Hz
M23259A Maximum Ambient Temperature: 125 F (52 C)
Maximum Water Pressure: 125 psi (862 kPa)

Pipe Size Capacity Maximum Close-off Pressure


Product Number (inch) DN (Cv) Connection Type Auxiliary End Switch (psi)
MZV524-T 1/2 in. DN15 5.8 Cv NPT — 20 psi
MZV524E-T 1/2 in. DN15 5.8 Cv NPT SPST 20 psi
MZV525 3/4 in. DN20 5.8 Cv Sweat — 20 psi
MZV525-T 3/4 in. DN20 5.8 Cv NPT — 20 psi
MZV525E 3/4 in. DN20 5.8 Cv Sweat SPST 20 psi
MZV525E-T 3/4 in. DN20 5.8 Cv NPT SPST 20 psi
MZV526 1 in. DN25 7.0 Cv Sweat — 17.5 psi
MZV526-T 1 in. DN25 7.0 Cv NPT — 17.5 psi
MZV526E 1 in. DN25 7.0 Cv Sweat SPST 17.5 psi
MZV526E-T 1 in. DN25 7.0 Cv NPT SPST 17.5 psi
MZV527 1 1/4 in. DN32 7.0 Cv Sweat — 17.5 psi
MZV527E 1 1/4 in. DN32 7.0 Cv Sweat SPST 17.5 psi

238 customer.honeywell.com 70-6910


Motorized Zone Valves
MZV Series Replacement Parts

Controls
Home
Maximum Maximum
Close-off Maximum Ambient
Pressure Water Pressure Temperature
Product Fre-
Number Description Voltage quency (psi) (psi) (kPa) (F) (C)

Indoor Air Quality


MZV520-RP Replacement operator for MZV 524/525/526/ 24 Vac 60 Hz — — — 240 F 115 C
527 with end switch

MZV521-RP Replacement operator for MZV 524/525/526/ 24 Vac 60 Hz — — — 240 F 115 C


527 without end switch

Combustion Controls
Residential
MZV525-RP Replacement valve cartridge for 1/2 in. 24 Vac 60 Hz 20 psi 125 psi 862 kPa 240 F 115 C
(MZV524, MZV524E) and 3/4 in. (MZV525,
MZV525E) valves
MZV526-RP Replacement valve cartridge for 1 in. 24 Vac 60 Hz 17.5 psi 125 psi 862 kPa 240 F 115 C

Hydronic Controls
(MZV526, MZV526E) and 1 1/4 in. (MZV527,
MZV527E) valves
SZ07-070 Conversion kit, telestat to Powertrack (MZV). — — — — — — —
Order with MZV520-RP. Includes adapter
ring and shaft extension.

Controls
Water
Building Automation
Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 239
Manifold Zone Valves
RAM Series Pre Assembled Radiant Manifold
Manifolds are used to control individual heating loop flow and
temperature controls through both Supply and Return
configurations. Individual tubing loops are connected to the
manifolds through connection adapters. Manifolds can be easily
grouped together in configurations of 2 Port, 3 Port and 4 Port by
using built-in union nut adapters allowing different zoning
configurations to meet job needs. Supply Manifolds-Without
Valves are used in combination with Return manifolds that contain
valves for individual loop flow and temperature control. Return
Manifolds-With Valves incorporate built-in balancing valves to
allow flow adjustment and balancing of individual heating loops.

Materials (Body): Bronze Maximum Differential Pressure Ratings (Close-off) (psi):


Dimensions, Approximate: 7 1/2 in long x 2 5/8 in wide x 8 1/4 in. high 40 ft., 17.5 psi
Flow Rate: 3.5 gpm Maximum Safe Operating Pressure (psi): 125 psi
Maximum Temperature: 220 F (104 C)

Product Number Connection Connection


Number of Zones Type Size Description Comments Used With
RAM200 2 Zones Threaded 3/4 in. Pre Assembled 2 Port Supply & Return Radiant Without Operators AQ2000 Controls
Manifold With Valves
RAM200FM 2 Zones Threaded 3/4 in. Pre Assembled 2 Port Supply & Return Manifold Without Operators AQ2000 Controls
with Flow Meters
RAM300 3 Zones Threaded 3/4 in. Pre Assembled 3 Port Supply & Return Radiant Without Operators AQ2000 Controls
Manifold With Valves
RAM300FM 3 Zones Threaded 3/4 in. Pre Assembled 3 Port Supply & Return Manifold Without Operators AQ2000 Controls
with Flow Meters
RAM400 4 Zones Threaded 3/4 in. Pre Assembled 4 Port Supply & Return Radiant Without Operators AQ2000 Controls
Manifold With Valves
RAM400FM 4 Zones Threaded 3/4 in. Pre Assembled 4 Port Supply & Return Manifold Without Operators AQ2000 Controls
with Flow Meters

240 customer.honeywell.com 70-6910


Manifold Zone Valves
RM Series Radiant Manifold

Controls
Home
Indoor Air Quality
————————————————— 2, 3, and 4 port Radiant Manifolds without valves (WOV models) —————————————————

Combustion Controls
Residential
—————————————————— 2, 3, and 4 port Radiant Manifolds with valves (WV models) ——————————————————

Hydronic Controls
————————————————— 2, 3, and 4 port Radiant Manifolds with flow meters (WFM models) ————————————————
Manifolds are used to control individual heating loop flow and
temperature controls through both Supply and Return

Controls
configurations. Individual tubing loops are connected to the

Water
manifolds through connection adapters. Manifolds can be easily
grouped together in configurations of 2 Port, 3 Port and 4 Port by
using built-in union nut adapters allowing different zoning
configurations to meet job needs. Supply Manifolds-Without
Valves are used in combination with Return manifolds that contain
valves for individual loop flow and temperature control. Return
Manifolds-With Valves incorporate built-in balancing valves to

Building Automation
allow flow adjustment and balancing of individual heating loops.
Materials (Body): Bronze Maximum Differential Pressure Ratings (Close-off) (psi):
Dimensions, Approximate: 3.28 in. high x 4.87 in. long x 1.6 in. deep 40 ft., 17.5 psi
Flow Rate: 3.5 gpm Maximum Safe Operating Pressure (psi): 125 psi
Maximum Temperature: 220 F (104 C)

Product Number of Connection


Number Zones Type Connection Size Description Comments
RM200WFM 2 Zones Threaded 3/4 in. 2 Port Return Manifold With Flow Meters Without Operators

Components
Commercial
RM200WOV 2 Zones Threaded 3/4 in. 2 Port Supply Radiant Manifold Without Valves Without Operators
RM200WV 2 Zones Threaded 3/4 in. 2 Port Return Radiant Manifold With Valves Without Operators
RM300WFM 3 Zones Threaded 3/4 in. 3 Port Return Manifold With Flow Meters Without Operators
RM300WOV 3 Zones Threaded 3/4 in. 3 Port Supply Radiant Manifold Without Valves Without Operators
RM300WV 3 Zones Threaded 3/4 in. 3 Port Return Radiant Manifold With Valves Without Operators
Pneumatic Controls

RM400WFM 4 Zones Threaded 3/4 in. 4 Port Return Manifold With Flow Meters Without Operators
RM400WOV 4 Zones Threaded 3/4 in. 4 Port Supply Radiant Manifold Without Valves Without Operators
RM400WV 4 Zones Threaded 3/4 in. 4 Port Return Radiant Manifold With Valves Without Operators
Industrial Combustion
Controls

70-6910 241
Manifold Zone Valves
MT4 Series Smart-T Thermal Electric Actuator
• No mounting tools required. Mounts easily to manifold with valve
adapter (included)
• Waterproof housing
• Auxiliary switch models for driving pumps or fans
• Low power consumption
• Normally closed action
• Compact design - installs in tight spaces
• Visual indicator shows valve position
• Silent operation
• Reliable long-term operation

Materials (Body): Plastic


Dimensions, Approximate: 2.24 high x 1.77 long x 1.65 deep
Current Draw: < 0.1A while operating; 0.7A during first 500
milliseconds
Maximum Fluid Temperature: 248 F (120 C)

Collar Diameter
Product Number Connection Type (inch) (mm) Description Used With
MT4-024S-NC Threaded 1 3/16 in. 30 mm MT4 Thermal Electric Actuator RM Series Manifolds

RM Series Manifold Accessories


Product Number Connection Type Connection Size Description Comments
FM100 Threaded — RM Series Manifold Flow Meter Replacement Top Replacement Parts
MA206-018 PEX R32 x 3/4 in. R32 x 3/4 in. Pex Adapter —
MA206-019 PEX R32 x 1 in. R32 x 1 in. PEX Adapter —
MA206-020 NPT R32 x 1 in. R32 x 1 in. NPT Adapter —
MA206-021 Sweat R32 x 1 in. R32 x 1 in. Sweat Adapter —
MA206-022 Sweat R32 x 1 1/4 in. R32 x 1 1/4 in. Sweat Adpater —
MBKT204 — — RM Series Manifold Bracket —
MC206-002 Threaded 30mm RM & SZ Series Manifold Valve Cap —
MC206-010 — — RM Series Union Coupling Gasket —
MC206-011 Threaded 1 in RM Series Manifold End Cap —
MPF203-023 Threaded 3/4 in RM Series Manifold Branch Cap —
MTK202 Threaded 1 in RM Series Manifold Union End Fitting with Thermometer —
YWM03-066 Threaded — RM Series Manifold Replacement Cartridge Pre-balancing feature

242 customer.honeywell.com 70-6910


Differential Pressure Regulators
D146 Differential Pressure Regulators

Controls
Home
Used to eliminate excessive pump head pressure when most
radiator valves are closed due to reduced demand.
• Install between supply and return sides of a hydronic system to
stabilize pressure differential and reduce the effects of demand
changes.
• Control maintains a constant differential between the two sides by
opening a bypass whenever the difference between supply and

Indoor Air Quality


return reaches the setpoint.
• Provides silent, trouble-free service.
• Easy installation; requires no electrical hookup.
• Easy adjustment of pressure by turning regulating cap.
• Built-in differential pressure indicator.
• Brass valve body with thermoplastic and stainless steel parts.
• Diaphragm of EPDM.

Combustion Controls
D146 Capacities

Residential
SIZE: 3/4 IN. SIZE: 1-1/4 IN.
14 TURNS
20 20
DIFFERENTIAL PSI (WATER)

DIFFERENTIAL PSI (WATER)


12
10 21 TURNS
8 20
15 15 18
16
6 14

Hydronic Controls
12
4 10
10 2 10 8
MINIMUM 6
4
(FULL CCW) 2
5 5 MINIMUM
(FULL CCW)

0 0
0 5 10 15 0 5 10 15 20 25 30 35 40 45 50
CAPACITY (GPM) CAPACITY (GPM) M3180A

Maximum Inlet Pressure Rating (psi): 85 Psi Materials: Brass (body), Stainless steel and engineered thermoplastics.

Controls
Water
Outlet Pressure Adjustment Range (psi): 0-17 psi EPDM diaphragm.
Temperature Range: 230 F (110 C)

Pipe Size Dimensions, Approximate


Product Number (inch) DN Pipe Connection Capacity (inch) (mm) Includes

Building Automation
D146M1032 3/4 in. DN20 Angle type, female 18 gpm; 6 1/4 in. high x 3 160 mm high x Built-in differential pressure
threaded NPT 120,000 Btu/hr 3/8 in. wide 86 mm wide indicator
D146M1040 1 1/4 in. DN32 Angle type, female 50 gpm; 8 1/2 in. high x 4 213 mm high x Built-in differential pressure
threaded NPT 395,000 Btu/hr 1/4 in. wide 109 mm wide indicator

Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 243
Air Vents and Eliminators
EA79 Industrial Air Vents
The Honeywell EA79 Industrial Air Vent purges air from high
pressure mains and equipment in hot or cold closed water
systems.
• Built-in shutoff valve for servicing without system shutdown.
• Built-in vacuum breaker.
• Removable float/valve assembly for easy servicing.
• Safety drain connection and vent cap with leakage guard.
• Brass shell construction.
• Internal parts made of corrosion-resistant and chemical-resistant
materials for use with water systems containing propylene glycol,
mineral oils, or petroleum-based oils. Replaces Hoffman # 79 or
Dole # 75 Vents.
• Maintains quiet and efficient operation.

Dimensions in inches (millimeters) EA79 construction

1-7/8 (48)
OUTER RING

1/2 (12)
RED VENT
BLACK COVER CAP WITH
ASSEMBLY LEAKAGE GUARD

VENT LEVER
O-RING

SEAT AREA— SPRING


MAKE SURE
! CAUTION!
Device may be hot AREA IS FREE OF
Do not use tools to adjust the e DIRT AND DEBRIS.
damage to vent may result. us FLOAT
only to adjust vent. A wrench
4-11/16 only on hex during installation
5 (120)
OPEN CLOSED
(128)

3/4 INCH
NPT EXTERNAL
THREAD

1/2 INCH NPT


INTERNAL THREAD
M6095C

EA79 capabilities
M6096A
300
Application: Hydronics
Corrosion Resistant: Internal parts made of corrosion-resistant and
250
chemical-resistant materials for use with hydronic systems that may
contain concentrations of propylene or ethylene glycol.
200 Maximum Operating Temperature: 250 F (120C)
Maximum Operating Pressure: 150 psi (1034 kPa)
CUBIC FEET/HOUR

150 Accessories:
Q122A1001 Safe waste connector (M20 thread connection)
Replacement Parts:
100
P79B1003 Replacement O-ring, cover and internals for EA79A1004

50

0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150
PRESSURE (PSI) M2760A

Product Number Connection Type Connection Size Description


EA79A1004 3/4 in. male NPT pipe thread with 1/2 in. female NPT pipe thread 3/4 in. Industrial automatic air vent

244 customer.honeywell.com 70-6910


Air Vents and Eliminators
EA122A Automatic Air Vent for Heating System Applications

Controls
Home
The Honeywell EA122A Automatic Air Vent purges air from high
pressure mains and equipment in hot or cold closed water
systems.
• Includes removable float/valve assembly for easy servicing.
• Not for use in steam systems.
• Body, cover and float assembly made of thermoplastics.
• Internal parts made of corrosion-resistant and chemical-resistant

Indoor Air Quality


materials for use with water systems containing light concentrations
of propylene glycol, mineral oils, or petroleum-based oils.
• Oil resistant seal.
• NBR seat disc and O-ring.

Combustion Controls
Residential
Dimensions in inches (millimeters) EA122A construction

1-7/8 (48) BLACK COVER RED VENT CAP


ASSEMBLY
7/16 (11)

O-RING

Hydronic Controls
9/16
(14) VENT LEVER
SEAT AREA—
MAKE SURE
AREA IS FREE OF
DIRT AND DEBRIS. SPRING

FLOAT
5-1/4
(133)

4-3/4
(121)

Controls
Water
SHUTOFF IS
BUILT-IN.
NO DRAIN-DOWN
REQUIRED.

Building Automation
1/8 INCH JUST TWIST AND YOU'RE
EXTERNAL READY TO SERVICE!
THREAD TWIST AGAIN AND YOU'RE
BACK ON LINE.

M5491D

M6585C

Application: Hydronic heating and cooling Accessories:


Corrosion Resistant: Internal parts made of corrosion-resistant and Q122A1001 Safe waste connector (M20 thread connection)
chemical-resistant materials for use with hydronic systems that may

Components
Commercial
contain concentrations of propylene or ethylene glycol. Replacement Parts:
Maximum Operating Temperature: 212 F (100 C) P122B1002 Cover assembly including cover, float assembly and vent
Maximum Operating Pressure: 90 psi (620 kPa) cap

Product Number Connection Type Connection Size Description


EA122A1002 Male NPT 1/8 in. Automatic air vent with built-in shutoff valve and leakage guard, oil resistant
Pneumatic Controls
Industrial Combustion
Controls

70-6910 245
Air Vents and Eliminators
EA122A Automatic Air Vent for Non-Heating System Applications
The Honeywell EA122A Automatic Air Vent purges air from high
pressure mains and equipment in hot or cold potable water
systems.
• Includes removable float/valve assembly for easy servicing.
• Not for use in steam systems.
• Body, cover and float assembly made of thermoplastics.
• Internal parts made of corrosion-resistant and chemical-resistant
materials for use with water systems containing light concentrations
of propylene glycol, mineral oils, or petroleum-based oils.
• Oil resistant seal.
• EPDM seat disc and O-ring.

Dimensions in inches (millimeters) EA122A construction

1-7/8 (48) BLACK COVER RED VENT CAP


ASSEMBLY
7/16 (11)

O-RING
9/16
(14) VENT LEVER
SEAT AREA—
MAKE SURE
AREA IS FREE OF
DIRT AND DEBRIS. SPRING

FLOAT
5-1/4
(133)

4-3/4
(121)

SHUTOFF IS
BUILT-IN.
NO DRAIN-DOWN
REQUIRED.
1/8 INCH JUST TWIST AND YOU'RE
EXTERNAL READY TO SERVICE!
THREAD TWIST AGAIN AND YOU'RE
BACK ON LINE.

M5491D

M6585C

Application: Potable water installations Accessories:


Corrosion Resistant: Internal parts made of corrosion-resistant and Q122A1001 Safe waste connector (M20 thread connection)
chemical-resistant materials for use with hydronic systems that may
contain concentrations of propylene or ethylene glycol. Replacement Parts:
Maximum Operating Temperature: 212 F (100 C) P122B1002 Cover assembly including cover, float assembly and vent
Maximum Operating Pressure: 90 psi (620 kPa) cap

Connection Connection
Product Number Type Size Description
EA122A1028 Male NPT 1/8 in. Automatic air vent with built-in shut off valve; includes EPDM seat disc and O-ring.
EA122B117 Male NPT 1/8 in. Automatic Air vent without build-in shutoff valve or leakage guard; includes EPDM seat disc and O-ring.

Air Vent Accessories and Replacement Parts


Product Number Description Used With
P79B1003 Replacement O-ring, cover and internals for EA79A1004 EA79A1004
P122B1002 Cover assembly including cover, float assembly and vent cap EA122A1002
P122B1010 Cover assembly including cover, float assembly and vent cap EA122A1028
Q122A1001 Safe waste connector (M20 thread connection) EA79; EA122A

246 customer.honeywell.com 70-6910


Air Vents and Eliminators
GoldTop™—Universal Air Vent for Residential and Commercial

Controls
Home
Heating and Cooling Systems.
Installers, wholesalers and OEMs can now stock one vent for all
their venting needs between 1 and 150 psi systems and obtain the
highest venting performance. Honeywell has reinvented the vent!
Air vents have been removing air from heating and cooling
systems for decades. Some were better than others. Many stopped

Indoor Air Quality


venting after initial filling. No one has, up to now, been able to
design a low cost vent that performs at both low and high
pressures. It was always one or the other. Honeywell's
revolutionary patented fulcrum design offers a venting rate of 3-4
times that of other products. It works when others stop venting at
higher pressures. The GoldTop offers convenient, one-fits-all
concept and is competitively priced.
• Patent No. 5,988,201.

Combustion Controls
Application: Residential or commercial heating and cooling systems
Materials (Body): Brass

Residential
Maximum Operating Temperature: 240 F (115 C)
Maximum Operating Pressure: 150 psi (1034 kPa)
Dimensions, Approximate: 1 27/32 in. diameter x 3 1/4 in. long
(24 mm diameter x 83 mm long)

Hydronic Controls
Weight
Connection Connection
Product Number Type Size (lb) (kg) Description
FV180 Male NPT 1/8 in. 0.4 lb 0.18 kg 1/8 in. NPT Goldtop Universal Air Vent for heating and cooling systems
FV180A Male NPT 1/4 in. 0.4 lb 0.18 kg 1/4 in. NPT Goldtop Universal Air Vent for heating and cooling systems
FV183 Male NPT 3/4 in. 0.4 lb 0.18 kg 3/4 in. NPT Goldtop Universal Air Vent for heating and cooling systems

Hygrovent—Automatic Vent for Hot Water or Steam

Controls
Water
The Honeywell Hygrovent is an automatic air vent for hot water and
steam systems. Install in baseboards, radiators, convectors and
high points in piping systems to remove air. The nickel-plated
valve has a quick venting design and a positive shut-off ball check.
Application: Hot water or steam
Materials (Body): Nickel Plated

Building Automation
Maximum Operating Temperature: 240 F (115 C)
Maximum Operating Pressure: Water: 125 psi; Steam: 10 psi
Dimensions, Approximate: 1 27/32 in. diameter x 3 1/4 in. long
(24 mm diameter x 83 mm long)

Weight

Components
Commercial
Product Number Connection Type Connection Size (lb) (kg) Description
HV190 Male NPT 1/8 in. 0.6 lb 0.3 kg 1/8 in. NPT Automatic Air Vent for hot water or steam

Pneumatic Controls
Industrial Combustion
Controls

70-6910 247
Air Vents and Eliminators
MaxiVent™—Air Vent for heating and cooling systems
The Maxivent features a low profile, fit anywhere solid brass body
and cover, and a high temperature polypropylene float.

Application: Residential or commercial heating and cooling systems


Materials (Body): Brass
Maximum Operating Temperature: 240 F (115 C)
Maximum Operating Pressure: 150 psi (1034 kPa)
Dimensions, Approximate: 2 in. high x 1 5/32 in. diameter
(51 mm high x 29 mm diameter)

Weight
Product Number Connection Type Connection Size (lb) (kg) Description
FV147 Male NPT 1/8 in. 0.12 lb 0.06 kg 1/8 in. NPT Air Vent for heating and cooling systems
FV147A Male NPT 1/4 in. 0.12 lb 0.06 kg 1/4 in. NPT Air Vent for heating and cooling systems

AP400 Air Purger


Air Purgers provide efficient separation of air and water in
hydronic heating systems. Heavy duty cast bronze construction
with tappings for expansion tank and automatic air vent
mountings. Removes entrapped air with internal baffle design
through continuous recirculation of heating system water with use
of air vent. Improves system efficiency, reduces noise and helps
extend component life.
• Heavy Duty cast iron construction
• 1 inch, 1 1/4 and 1 1/2 inch models (inlet and outlet)
• 1/2 inch bottom tapping for expansion tank mount
• 1/8 inch top tapping for air vent mount
• Directional flow arrow for correct installation

Application: Closed heating systems


Materials (Body): Cast Iron
Maximum Operating Temperature: 275 F (135 C)
Maximum Operating Pressure: 125 psi (862 kPa)
Dimensions, Approximate: 6 in. long x 3-3/4 in. high x 2-3/8 in. wide
(152 mm long x 95 mm high x 60 mm wide)

Weight
Product Number Pipe Size Connection Type Connection Size (lb) (kg) Description
AP400 1 in. Female NPT Bottom: 1/2 in.; Top: 1/8 in. 4.2 lb 1.9 kg 1 in. NPT Air Purger for closed heating systems
AP401 1 1/4 in. Female NPT Bottom: 1/2 in.; Top: 1/8 in. 3.8 lb 1.7 kg 1 1/4 in. NPT Air Purger for closed heating systems
AP402 1 1/2 in. Female NPT Bottom: 1/2 in.; Top: 1/8 in. 8.6 lb 3.9 kg 1 1/2 in. NPT Air Purger for closed heating systems

248 customer.honeywell.com 70-6910


Air Vents and Eliminators
SuperVent® Air Eliminator

Controls
Home
Eliminates Air from Hydronic Heating Systems without Bleeding
Conventional automatic air vents installed in Hydronic heating
systems can leak and cause inefficient system operation. To
effectively eliminate air from the system without bleeding, air
bubbles ned to be vented. The NEW Honeywell SuperVent purges
air through a no clog vent assembly that controls dirt and debris to

Indoor Air Quality


minimize air vent fouling.
• No clog vent.
• Dirt and Debris resistant.
• 360 degree adjustable collar ring for installation flexibility.
• Stainless steel concentrator which eliminates gurgling noise.
• Bronze body for rigid construction.
• Threaded connections.

Combustion Controls
Residential
Hydronic Controls
How it works Application: Residential or Commercial closed loop hydronic heating or
chilled water systems
AUTOMATIC Materials (Body): Bronze
AIR VENTING Maximum Operating Temperature: 240 F (115 C)
Maximum Operating Pressure: 125 psi (862 kPa)

Controls
Water
AIR NO AIR
BUBBLES BUBBLES

Building Automation
IN OUT

M13815

Maximum
Diameter Dimensions, Approximate Capacity Weight
Connection Connection
Product Number Pipe Size Type (inch) (mm) (inch) (mm) Size (Cv) (lb) (kg)

Components
Commercial
PV075 3/4 in. Female NPT 1 13/16 in. 46 mm 6 29/32 in. high x 176 mm high x 3/4 in. bottom inlet 13 Cv 2 lb 0.9 kg
2 11/16 in. wide 68 mm wide
PV075S 3/4 in. Sweat 1 13/16 in. 46 mm 6 29/32 in. long x 176 mm high x 3/4 in. bottom inlet 13 Cv 2 lb 0.9 kg
3 3/16 in. wide 81 mm long
PV100 1 in. Female NPT 2 3/32 in. 53 mm 6 1/2 in. high x 192 mm high x 1 in. bottom inlet 22 Cv 2.75 lb 1.2 kg
3 3/32 in. wide 79 mm long
PV100S 1 in. Sweat 2 3/32 in. 53 mm 6 1/2 in. high x 192 mm long x 1 in. bottom inlet 22 Cv 2.75 lb 1.2 kg
Pneumatic Controls

3 11/16 in. wide 94 mm wide


PV125 1 1/4 in. Female NPT 2 1/2 in. 64 mm 7 27/32 in. high x 199 mm high x 1 1/4 in. bottom 38 Cv 3.5 lb 1.6 kg
3 11/16 in. wide 94 mm wide inlet
PV125S 1 1/4 in. Sweat 2 1/2 in. 64 mm 7 27/32 in. high x 199 mm high x 1 1/4 in. bottom 38 Cv 3.5 lb 1.6 kg
4 13/32 in. wide 112 mm wide inlet
PV150 1 1/2 in. Female NPT 3 3/32 in. 79 mm 9 5/32 in. high x 233 mm high x 1 1/2 in. bottom 50 Cv 5.2 lb 2.4 kg
4 5/16 in. long 110 mm long inlet
Industrial Combustion

PV200 2 in. Female NPT 4 in. 102 mm 10 9/32 in. high x 261 mm high x 2 in. bottom inlet 95 Cv 8 lb 3.6 kg
5 3/16 in. long 132 mm long
Controls

70-6910 249
Air Vents and Eliminators
SuperVent® Air Eliminator Universal Models
Eliminate Air from Hydronic Heating Systems without Bleeding
Conventional automatic air vents installed in Hydronic heating
systems can leak and cause inefficient system operation. To
effectively eliminate air from the system without bleeding, air
bubbles ned to be vented. The NEW Honeywell SuperVent purges
air through a no clog vent assembly that controls dirt and debris to
minimize air vent fouling.
• No clog vent.
• Dirt and Debris resistant.
• 360 degree adjustable collar ring for installation flexibility.
• Stainless steel concentrator which eliminates gurgling noise.
• Bronze body for rigid construction.
• Threaded connections.

Application: Residential or Commercial closed loop hydronic heating or


chilled water systems
Materials (Body): Bronze
Maximum Operating Temperature: 240 F (115 C)
Maximum Operating Pressure: 125 psi (862 kPa)

Maximum Diameter Dimensions, Approximate Capacity Weight


Connection Connection
Product Number Pipe Size (inch) (mm) (inch) (mm) Type Size (Cv) (lb) (kg)
PVU075 3/4 in. 1 13/16 in. 46 mm 7 9/32 in. long x 185 mm long x Female NPT 3/4 in. bottom 3.6 Cv 2.1 lb 0.9 kg
2 11/16 in. wide 68 mm wide inlet
PVU100 1 in. 2 3/32 in. 53 mm 7 27/32 in. high x 4 199 mm high x Female NPT 1 in. bottom 6.2 CV 2.8 lb 1.3 kg
13/32 in. wide 112 mm wide inlet
PVU125 1 1/4 in. 2 1/2 in. 64 mm 8 1/4 in. high x 212 mm high x Female NPT 1 1/4 in. bottom 10.5 Cv 3.6 lb 1.6 kg
3 11/16 in. wide 94 mm long inlet
PVU150 1 1/2 in. 3 3/32 in. 79 mm 9 13/32 in. high x 4 239 mm high x Female NPT 1 1/2 in. bottom 14.3 Cv 5.2 lb 2.4 kg
5/16 in. wide 110 mm long inlet
Typical Installation

SUPER VENT UNIVERSAL SUPERVENT


INSTALLATION

OUT TO SYSTEM PIPING SYSTEM FILL

FILL VALVE &


BACKFLOW
PREVENTER

EXPANSION TANK
OUT FROM BOILER DIAGRAM FOR ILLUSTRATION PURPOSES ONLY.
M13834

250 customer.honeywell.com 70-6910


Air Vents and Eliminators
SuperVent® Vent Top for Heating and Cooling Systems

Controls
Home
The Supervent has high venting capacity and incorporates a check
valve. Use with SuperVent PV Series products.
Application: Residential or commercial heating and cooling systems
Materials (Body): Brass
Maximum Operating Temperature: 240 F (115 C)
Maximum Operating Pressure: 150 psi (1034 kPa)

Indoor Air Quality


Dimensions, Approximate: 3 in. high x 2 in. diameter
(76 mm high x 51 mm diameter)

Combustion Controls
Residential
Maximum Diameter Weight
Product Number Pipe Size Connection Type (inch) (mm) Connection Size (lb) (kg)
SV173 3/8 in. NPT 2 in. 51 mm 3/8 in. 0.43 lb 0.19 kg

Hydronic Controls
SV175 1/2 in. NPT 2 in. 51 mm 1/2 in. 0.43 lb 0.19 kg

SuperVent Replacement Parts


Product Number Description
PV-001RP Replacement Air Vent Assembly for PowerVent (pre 2004) size 3/4 in., 1 in., 1 1/4 in., 1 1/2 in. and 2 in.
PV-020RP PV SuperVent Vent Top Replacement (New Style 90 Degree)

Controls
Water
Building Automation
Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 251
FlowCheck Valves
FlowCheck—Gravity Check Valves
Honeywell FlowChecks prevent the flow of water to any part of a
system when the pump is shut off. They permit summer/winter
operation of indirect water heaters. Honeywell FlowChecks are
easy to clean. Just unscrew the top of the valve for inspection and
cleaning. Bronze and brass construction. To allow gravity flow, the
FlowCheck can be changed to manual operation by turning the
hand wheel counterclockwise (open position).
Type: Horizontal
Materials (Body): Brass
Dimensions, Approximate: 3 11/16 in. high x 3 5/16 in. long x
1 1/2 in. wide

Weight
Product Number Size (inch) Connection Type (lb) (kg)
FC200SB 3/4 in. Sweat 1.1 lb 0.5 kg
FC201SB 1 in. Sweat 1.5 lb 0.68 kg

252 customer.honeywell.com 70-6910


Backflow Preventers
Backflow Preventers with Dual Check for Domestic Water

Controls
Home
Backflow Preventers-Dual Check for Domestic water
• Dual Check Valves may be installed in either a vertical or horizontal
position and should be installed immediately down stream of the
water meter.

Dimensions, Approximate:
4 3/8 in. long x 2 1/8 in. wide (111 mm long x 54 mm wide)

Indoor Air Quality


Connection Type: NPT
Maximum Ambient Temperature: 180 F (82 C)
Maximum Operating Pressure: 150 psi (1034 kPa)
Approvals:
Canadian Standards Association: Certified
Other: ASSE Certified

Connection Size Weight

Combustion Controls
Product Number (inch) DN (lb) (kg) Description

Residential
BP700 3/4 in. DN20 1.0 lb 0.45 kg Dual check 3/4 in. NPT
BP701 1 in. DN25 1.4 lb 0.64 kg Dual Check 1 in. NPT

Backflow Preventers with Intermediate Atmospheric Vent for


Heating Systems

Hydronic Controls
The BP900 is a double check backflow preventer with an
intermediate vacuum breaker designed to prevent the backflow of
contaminated water into the potable water supply. Designed for the
use on small supply lines, it protects against both backflow and
back siphonage for continuous pressure applications.
• It is ideal for boiler feed lines, livestock drinking fountains, trailer park
water hook-ups, laboratory equipment and numerous other
applications.
• Suitable for either hot or cold water service, the BP900 is designed
for non-continuous backflow temperatures up to 250 F and working

Controls
supply pressures up to 175 psi.

Water
Dimensions, Approximate:
4 7/8 in. long x 2 1/2 in. wide (124 mm long x 63 mm wide)
Connection Type: NPT
Maximum Ambient Temperature: 250 F (121 C)
Maximum Operating Pressure: 175 psi (1207 kPa)

Building Automation
Approvals:
Canadian Standards Association: Certified
Other: ASSE Certified

Connection Size Weight


Product Number (inch) DN (lb) (kg) Description
BP900 1/2 in. DN15 1.2 lb 0.54 kg Double check intermediate vacuum breaker - 1/2 in. NPT
BP901 3/4 in. DN20 1.2 lb 0.54 kg Double check intermediate vacuum breaker - 3/4 in. NPT
Typical Installation

Components
Commercial
BP 900
BACKFLOW PREVENTER BOILER
FEED VALVE
INLET
SUPPLY
Pneumatic Controls

VENT

AIR GAP
REQUIRED RETURN

BOILER
Industrial Combustion

M23854
Controls

70-6910 253
Boiler Fill Valves
FM Boiler Fill Valves
Pressure regulating valve for automatic control of boiler feed water
and other pressure reducing applications. Especially constructed
for expansion tank mounting.
• Fast fill feature.
• Built in check valve.
Application: Fast fill pressure regulating boiler feed valve with check
valve.
Connection Type: NPT
Inlet Connection Size: 1/2 in.
Inlet Connection Type: Sweat or Threaded
Pipe Size: 1/2 in.
Materials (Body): Brass
Maximum Ambient Temperature: 212 F (100 C)

Regulating
Maximum Operating Pressure Dimensions,
Pressure Range Approximate Weight
Product
Number (kPa) (psi) (psi) (inch) (lb) Description
FM450 1034 kPa 150 psi 4 psi to 60 psi 4 1/8 in. high x 5 1.8 lb 1/2 in. sweat union pressure reducing valve, includes union nut
5/16 in. long and both sweat and NPT tailpiece
FM911 1034 kPa 150 psi 4 psi to 60 psi — 4 lb 1/2 in. NPT Backflow preventer and boiler fill valve assembly,
includes union nut and both sweat and NPT tailpiece

254 customer.honeywell.com 70-6910


Thermometers and Gauges
Sweat and Threaded Thermometers with Thermowells

Controls
Home
Thermometer with Sweat or Threaded Connection.
• Brass thermowell is included to allow the thermometer to be
removed without draining the system.
• 2 inch or 2 1/2 inch Dial.
Materials: Case: steel; Well: brass
Temperature Range: 32 F to 250 F (0 C to 121 C)

Indoor Air Quality


Connection Size: 1/2 in.

Combustion Controls
Residential
Dial Size Length Weight
Product Number Connection Type (inch) (mm) (inch) (mm) (lb) (kg)
GS200 Sweat 2 in. 51 mm 1 1/4 in. 51 mm 0.21 lb 0.095 kg
GS250 Sweat 2 1/2 in. 63.5 mm 1 1/4 in. 51 mm 0.25 lb 0.114 kg
GT161 NPT 2 in. 51 mm 1 1/2 in. 51 mm 0.21 lb 0.095 kg
GT162 NPT 2 1/2 in. 63.5 mm 1 1/2 in. 51 mm 0.25 lb 0.114 kg

Hydronic Controls
Tridicators
Pressure/temperature gauge with relief set point indicator for
boilers and shut off valve.

Temperature Range: 60 F to 320 F (15 C to 160 C)


Connection Size: 1/4 in.
Connection Type: NPT
Maximum Operating Pressure: 75 psi

Controls
Water
80 100 12
60 0
40
14
40

0
20

60

E SS U
160
20

PR

RE

psi feet H2O


¡F ¡C

Building Automation
320
160
60

20

300
TE

MP
80

ERATUR
160
40

280
10

0
0

60 12
0

1/4 IN. NPT


12

26

80 100
0

14 0
0 24
160 220
180 200

M23258

Dial Size Length Weight


Product Number (inch) (mm) (inch) (mm) (lb) (kg) Comments

Components
Commercial
TD-090 3 1/8 in. 79.4 mm 1 21/32 in. 23 mm 0.3 lb 0.14 kg Pressure/temperature gauge with relief set point indicator
TD-165 3 1/8 in. 79.4 mm 2 in. 42.1 mm 0.3 lb 0.14 kg Pressure/temperature gauge with relief set point indicator
TDV-040 3 1/8 in. 79.38 mm 29/32 in 23.02 mm 0.4 lb 0.18 kg Pressure/temperature gauge with relief set point indicator and
shut off valve
Pneumatic Controls
Industrial Combustion
Controls

70-6910 255
Residential Expansion Tanks
TX Series Expansion Tanks - Domestic Hot Water
The Honeywell Thermal Expansion Absorber is a welded,
pressurized expansion tank with a butyl diaphragm to control
excess pressure in potable hot water systems. The Thermal
Expansion Tank controls pressure build-up in the system,
eliminates relief valve spillage, protects fixtures and extends water
heater life.
• Heavy duty butyl rubber diaphragm (FDA approved) isolates water
from air.
• Polypropylene liner, 100% non-metallic, non-corrosive water
reservoir.
• Full size range: 2-528 gals., for all water heating volumes (ASME
available).
• Prevents water hammer.
• Maintenance free.
• Protects water heater from harmful pressure cycling.
• Allows storage of expanded water with no increase in system
pressures.

Maximum Operating Temperature: 200 F (93 C) Materials


Maximum Operating Pressure: 150 psi (1034 kPa) Shell: Steel
Precharge: 40 psi Connection: Brass
Comments: Potable Liner: Polypylene
Diaphragm: Butyl

Maximum
Con- Acceptance
nection Diameter Height Volume Volume Weight
Size Connection
Product Number (inch) Type (inch) (mm) (inch) (mm) (gal) (L) (gal) (L) (lb) (kg)
TX-5 3/4 in. Male NPT 8 in. 203.2 mm 12 5/8 in. 321 mm 2.0 gal 7.6 L 0.9 gal 3.41 L 5 lb 2.27 kg
TX-12 3/4 in. Male NPT 11 in. 279 mm 12 5/8 in. 321 mm 4.4 gal 16.7 L 3.2 gal 12.1 L 5 lb 2.27 kg
TX-25V 3/4 in. Female NPT 15 3/8 in. 390.5 mm 19 1/4 in. 489 mm 10.3 gal 39 L 10.3 gal 39 L 23 lb 10.43 kg
TX-30V 3/4 in. Female NPT 15 3/8 in. 390.5 mm 23 7/8 in. 606 mm 14.0 gal 53.1 L 11.3 gal 42.8 L 25 lb 11.34 kg
TX-42V 3/4 in. Female NPT 15 3/8 in. 390.5 mm 31 5/8 in. 803 mm 20.0 gal 75.7 L 11.4 gal 43.2 L 33 lb 14.97 kg
TX-60V 1 1/4 in. Female NPT 22 in. 558.8 mm 29 5/8 in. 752.5 mm 34.0 gal 128.7 L 34.0 gal 128.7 L 61 lb 27.67 kg
TX-80V 1 1/4 in. Female NPT 22 in. 558.8 mm 40 1/2 in. 914 mm 44.0 gal 166.5 L 33.9 gal 128.3 L 63 lb 28.58 kg
TX-180V 1 1/4 in. Female NPT 22 in. 558.8 mm 46 3/4 in. 1187.5 mm 62.0 gal 235 L 34.1 gal 129.1 L 92 lb 41.73 kg
TX-210V 1 1/4 in. Female NPT 26 in. 660.4 mm 47 1/4 in. 1200 mm 86.0 gal 325.5 L 46.4 gal 175.6 L 123 lb 55.79 kg

Service Check Valves


Service Check Valves for air vents and expansion tanks allow easy
field service without draining system.

CAUTION
Reduce system temperature to ambient and
pressure to 0 psi before servicing component.
Failure to do so my result in injuries.
Maximum Operating Temperature: 240 F (115 C)
Maximum Operating Pressure: 100 psi (689 kPA)

Product Number Connection Size (inch) Connection Type


SCV-0125 1/8 in. Inlet FNPT, Outlet MNPT
SCV-050 1/2 in. Inlet FNPT, Outlet MNPT

256 customer.honeywell.com 70-6910


Residential Expansion Tanks
TK300 Series Expansion Tanks - Heating

Controls
Home
Honeywell Expansion Tanks are designed to absorb hot water
expansion in closed heating systems. They are equipped with
butyl diaphragms to separate the air from the system water
(glycol). The tanks are a welded, not clamped design. Pre-
pressurized at 12 psi, the tank keeps fluids circulating and
maintains minimum system pressure. Honeywell tanks resist
waterlogging, loss of pressure through relief valve spills, loss of

Indoor Air Quality


BTUs and reduce circulator running time. Use the super efficient
Honeywell PowerVent or air vents to remove air and micro-bubbles
from the system for maximum performance.
• Butyl/EPDM diaphragm- 9 times better than natural rubber
• Deep-drawn steel tank
• Controls system pressure
• Air-tight cushion-factory pre-charged to 12 psig and 100% tested

Combustion Controls
Maximum Operating Temperature: 240 F (115 C) Materials: steel shell, heavy duty butyl diaphragm
Maximum Operating Pressure: 100 psi (689 kPA) Comments: Heating

Residential
Maximum
Acceptance
Diameter Height Volume Volume Weight
Connection Connection
Product Number Size (inch) Type (inch) (mm) (inch) (mm) (gal) (L) (gal) (L) (lb) (kg)
TK300-15 1/2 in. Male NPT 8 in. 203.2 mm 12 5/8 in. 321 mm 2.0 gal 7.6 L 1 gal 3.8 L 5 lb 2.3 kg

Hydronic Controls
TK300-30 1/2 in. Male NPT 11 in. 279 mm 15 1/2 in. 394 mm 4.4 gal 16.7 L 2.5 gal 9.5 L 9 lb 4.1 kg
TK300-60 1/2 in. Male NPT 11 in. 279 mm 23 in. 584 mm 7.6 gal 28.8 L 2.5 gal 9.5 L 14 lb 6.4 kg
TK300-90 1/2 in. Male NPT 15 3/8 in. 390.5 mm 21 in. 533 mm 14.0 gal 53.1 L 11.5 gal 40.1 L 23 lb 10.4 kg

Expansion Tank Sizing based on BTU’s


Boiler Type of Radiation
Net Output in 1000’s of Finned Tube Baseboard Convectors or

Controls
Water
BTU/Hr or Radiant Panel Unit Heaters Radiators Cast Iron Baseboard Cast Iron
MBH Use Model Use Model Use Model Use Model
25 TK300-15 TK300-15 TK300-15 TK300-15
50 TK300-15 TK300-15 TK300-30 TK300-30
75 TK300-30 TK300-30 TK300-30 TK300-60

Building Automation
100 TK300-30 TK300-30 TK300-60 TK300-60
125 TK300-30 TK300-60 TK300-60 TK300-90
150 TK300-30 TK300-60 TK300-90 TK300-90
175 TK300-60 TK300-60 XPS-030V XPS-030V
200 TK300-60 TK300-60 XPS-030V XPS-030V
250 TK300-60 TK300-90 XPS-030V XPS-040V
300 TK300-90 XPS-030V XPS-030V XPS-040V

Components
Commercial
350 XPS-030V XPS-030V XPS-040V XPS-060V
400 XPS-030V XPS-040V XPS-040V XPS-060V

Pneumatic Controls
Industrial Combustion
Controls

70-6910 257
Residential Expansion Tank Kits
Boiler Trim Kit with SuperVent
Honeywell TK Series Combo Boiler Trim kits are a quick and
convenient way to purchase the key "boiler trim" used by installers
when performing a boiler change out. All Combo Trim Kits with
SuperVent include expansion tank and SuperVent high
performance air eliminator; selected models also include FM911
combination boiler fill valve/backflow preventer and/or service
check valves for in-line servicing of the expansion tank.

Maximum Operating Temperature: 240 F (115 C)


Maximum Operating Pressure: 100 psi (689 kPA)
Diameter: 11 in. (279 mm)
Maximum Acceptance Volume: 2.5 gal. (9.5 L)

Height Volume Weight


Connection Size
Product Number (inch) Connection Type (inch) (mm) (gal) (L) (lb) (kg) Includes
TK30PV100FM SuperVent: 1 in. SuperVent: Female NPT 15 1/2 in. 394 mm 4.4 gal 16.7 L 16 lb 7.3 kg TK300-30, PV100,
Tank: 1/2 in. Tank: Male NPT SCV-050, FM911
TK30PV100FMNC SuperVent: 1 in. SuperVent: Female NPT 15 1/2 in. 394 mm 4.4 gal 16.7 L 16 lb 7.3 kg TK300-30, PV100,
Tank: 1/2 in. Tank: Male NPT FM911
TK30PV100SFM SuperVent: 1 in. SuperVent: Sweat 15 1/2 in. 394 mm 4.4 gal 16.7 L 16 lb 7.3 kg TK300-30, PV100S,
Tank: 1/2 in. Tank: Male NPT SCV-050, FM911
TK30PV125 SuperVent: 1 1/4 in. SuperVent: Female NPT 15 1/2 in. 394 mm 4.4 gal 16.7 L 12.8 lb 5.8 kg TK300-30, PV125,
Tank: 1/2 in. Tank: Male NPT SCV-050
TK30PV125FM SuperVent: 1 1/4 in. SuperVent: Female NPT 15 1/2 in. 394 mm 4.4 gal 16.7 L 16.8 lb 7.6 kg TK300-30, PV125,
Tank: 1/2 in. Tank: Male NPT SCV-050, FM911
TK30PV125FMNC SuperVent: 1 1/4 in. SuperVent: Female NPT 15 1/2 in. 394 mm 4.4 gal 16.7 L 16.8 lb 7.6 kg TK300-30, PV125,
Tank: 1/2 in. Tank: Male NPT FM911
TK30PV125SFM SuperVent: 1 1/4 in. SuperVent: Sweat 15 1/2 in. 394 mm 4.4 gal 16.7 L 16.8 lb 7.6 kg TK300-30, PV125S,
Tank: 1/2 in. Tank: Male NPT SCV-050, FM911
TK60PV100SFMNC SuperVent: 1 1/4 in. SuperVent: Female NPT 23 in. 584 mm 4.4 gal 16.7 L 15.3 lb 6.9 kg TK300-60, PV100S,
Tank: 1/2 in. Tank: Male NPT FM911
TK60PV125FMNC SuperVent: 1 1/4 in. SuperVent: Female NPT 23 in. 584 mm 7.6 gal 28.8 L 17.5 lb 7.95 kg TK300-60, PV125,
Tank: 1/2 in. Tank: Male NPT FM911
TK60PV125SFMNC SuperVent: 1 1/4 in. SuperVent: Sweat 23 in. 584 mm 7.6 gal 28.8 L 17.5 lb 7.95 kg TK300-60, PV125S,
Tank: 1/2 in. Tank: Male NPT FM911

258 customer.honeywell.com 70-6910


Residential Expansion Tank Kits
Boiler Trim Kit with Air Purger

Controls
Home
Honeywell TK Series Boiler Trim kits are a quick and convenient
way to purchase the key "boiler trim" used by installers when
performing a boiler change out. All Trim Kits with Purgers include
expansion tank, air purger and air vent; selected models also
include FM911 combination boiler fill valve/backflow preventer
and/or service check valves for in-line servicing of the expansion
tank and air vent.

Indoor Air Quality


Maximum Operating Temperature: 240 F (115 C)
Maximum Operating Pressure: 100 psi (689 kPA)
Diameter: 11 in. (279 mm)
Maximum Acceptance Volume: 2.5 gal. (9.5 L)

Combustion Controls
Height Volume Weight
Connection Size

Residential
Product Number (inch) Connection Type (inch) (mm) (gal) (L) (lb) (kg) Includes
TK300-30A-1 Air Purger: 1 in. Tank: Male NPT 15 1/2 in. 394 mm 4.4 gal 16.7 L 13 lb 5.9 kg TK300-30, AP400, FV180,
Tank: 1/2 in. Air Purger: Female NPT SCV-0125, SCV-050
TK300-30A-1FM Air Purger: 1 in. Tank: Male NPT 15 1/2 in. 394 mm 4.4 gal 16.7 L 16.6 lb 7.5 kg TK300-30, AP400, FV180,
Tank: 1/2 in. Air Purger: Female NPT SCV-0125, SCV-050,
FM911
TK300-30A-1FMNC Air Purger: 1 in. Tank: Male NPT 15 1/2 in. 394 mm 4.4 gal 16.7 L 16.6 lb 7.5 kg TK300-30, AP400, FV180,

Hydronic Controls
Tank: 1/2 in. Air Purger: Female NPT FM911
TK300-30A-2 Air Purger: 1 1/4 in. Tank: Male NPT 15 1/2 in. 394 mm 4.4 gal 16.7 L 13 lb 5.9 kg TK300-30, AP401, FV180,
Tank: 1/2 in. Air Purger: Female NPT SCV-0125, SCV-050
TK300-30A-2FM Air Purger: 1 1/4 in. Tank: Male NPT 15 1/2 in. 394 mm 4.4 gal 16.7 L 16.6 lb 7.5 kg TK300-30, AP401, FV180,
Tank: 1/2 in. Air Purger: Female NPT SCV-0125, SCV-050,
FM911
TK300-30A-2FMNC Air Purger: 1 1/4 in. Tank: Male NPT 15 1/2 in. 394 mm 4.4 gal 16.7 L 16.6 lb 7.5 kg TK300-30, AP401, FV180,
Tank: 1/2 in. Air Purger: Female NPT FM911

Controls
Water
Building Automation
Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 259
Thermostatic Radiator Valves and Actuators
V135 Thermostatic Mixing or Diverting Valves
Thermostatic Mixing or Diverting Valves for use in hydronic
heating systems as a three-way mixing or diverting valve; controls
loop temperature in radiant heating systems.
• Includes plastic handle for manual operation.
• Knurled ring on T100R control head for easy attachment to V135.

Application: Thermostatic mixing/diverting valve for use in hydronic


heating systems. Controls loop temperature in radiant heating
systems.
Materials (Body): Bronze
Differential Pressure Rating: 17 psi maximum
Pressure Ratings (Steam): 232 psi maximum (1601 kPa)
Temperature Rating: 248 F Maximum (120 C Maximum)
Collar Diameter: 1 3/16 in. (30 mm)
Used With: T100R
Replacement Parts:
0900661 Replacement cartridge for V135A 1 in. and 1 1/4 in. models

Pipe Size Capacity Dimensions, Approximate


Connection
Product Number (inch) DN Body Pattern (Cv) Type (inch) (mm)
V135A1006 3/4 in. DN20 Three-way 3.7 Cv Sweat 2 9/16 in. x 5 1/8 in. 64 mm x 128 mm
V135A1014 1 in. DN25 Three-way 5.8 Cv Sweat 2 15/16 in. x 5 13/16 in. 74 mm x 148 mm
V135A1022 1 1/4 in. DN32 Three-way 5.8 Cv NPT 3 3/4 in. x 7 1/8 in. 95 mm x 180 mm
V135A1048 1 1/2 in. DN40 Three-way 11.7 Cv NPT 3 3/4 in. x 7 3/8 in. 95 mm x 188 mm
V135A1063 1 1/4 in. DN32 Three-way 5.8 Cv Sweat 3 3/8 in. x 6 3/8 in. 86 mm x 162 mm

T100R Thermostatic Mixing or Diverting Valve Actuator


For use in hydronic heating systems with V135 Valves in a three-
way mixing or diverting application. Controls loop temperature in
radiant heating systems.
• T100R Thermostatic Actuator includes strap-on-pipe sensor.
• Knurled ring on T100R control head for easy attachment to V135.

Application: Three-way mixing and diverting applications in hydronic


heating systems requiring remote sensing
Used With Valve: V135
Collar Diameter: 1 3/16 in. (30 mm)
Replacement Parts:
0900661 Replacement cartridge for V135A 1 in. and 1 1/4 in. models

Capillary Length Temperature Range


Product Setpoint
Number (ft) (m) (F) (C) (Integral or Remote)
T100R1004 6 ft. 8 in. 2m 50 F to 122 F 10 C to 50 C Remote
T100R1012 6 ft. 8 in. 2m 86 F to 158 F 30 C to 70 C Remote

V135 Thermostatic Mixing or Diverting Valves Replacement


Cartridges
Product Number Description Used With
V135A-12VE Replacement cartridge for V135A 1/2 in. and 3/4 in. models V135
V135A-1VE Replacement cartridge for V135A 1 in. and 1 1/4 in. models V135
V135A-11/2VE Replacement cartridge for V135A 1 1/2 in. and 2 in. models V135

260 customer.honeywell.com 70-6910


Thermostatic Radiator Valves and Actuators
V110 High Capacity Thermostatic Radiator Valves

Controls
Home
High Capacity Thermostatic Radiator Valves with T104
Thermostatic Actuators provide precise and automatic control of
room temperature in two-pipe systems by modulating the flow of
hot water or steam through free-standing radiators, convectors
and other heating units with high capacity requirements.
• Designed with the higher capacity normally required by North
American heating systems.

Indoor Air Quality


• Valve seat disc, which is made of resilient material (EPDM), ensures
V110D tight shutoff on steam or hot water systems.
• Nickel-plated bronze casted body with working parts in cartridge
insert for ease of service.
• All working parts are replaceable using service tool (MT100C1011)
while valve remains in service, in-line, under pressure.
V110F • Valves normally open without control mounted.
• Valves may be used with T104 Thermostatic Actuators.
• Meet ASHRAE Standard 102-1989.

Combustion Controls
V110E

Residential
Dimensions in inches (millimeters)
V110F (Horizontal Angle Body)
V110D (Straight Body)

Hydronic Controls
C MAX
B

1
C MAX A

A A B C MAX
PIPE SIZE IN. (MM) IN. (MM) 1 IN. (MM)
A C MAX 1/2 INCH 2-1/4 (57) 1 (25) 5-1/8 (130)
PIPE SIZE IN. (MM) 1 IN. (MM)
3/4 INCH 2-9/16 (65) 1-1/8 (29) 5-1/4 (133)
1/2 INCH 3-3/4 (95) 4-3/4 (121)

Controls
Water
1 INCH 2-15/16 (74) 1-3/16 (30) 5-1/4 (133)
3/4 INCH 4-1/8 (105) 4-3/4 (121)
1-1/4 INCH 3-1/2 (89) 2-3/16 (56) 5-1/4 (133)
1 INCH 4-15/16 (125) 4-3/4 (121)

1-1/4 INCH 5-7/8 (149) 5 (127) 1 C MAX DIMENSION IS WITH T104 CONTROL INSTALLED. M18961A

Capacity: high
1 C MAX DIMENSION IS WITH T104 CONTROL INSTALLED. M18959A
Materials (Body): Nickel Plated Bronze

Building Automation
Differential Pressure Rating: 17 psi maximum
V110E (Angle Body) Pressure Ratings (Hot Water): 150 psi maximum (1034 kPa
maximum)
Pressure Ratings (Steam): 15 psi maximum (103 kPa)
Temperature Rating: 248 F Maximum (120 C Maximum)
1 Cartridge Change Tool: Yes - Use MT110C1011
C MAX Used With: T104

Components
Commercial
B

A B C MAX
Pneumatic Controls

PIPE SIZE 1
IN. (MM) IN. (MM) IN. (MM)
1/2 INCH 2-9/16 (65) 1 (25) 4-3/4 (121)

3/4 INCH 2-5/8 (67) 1-1/8 (29) 4-3/4 (121)

1 INCH 3 (76) 1-5/16 (33) 4-3/4 (121)

1-1/4 INCH 3-5/8 (90) 1-11/16 (43) 5 (127)

1 C MAX DIMENSION IS WITH T104 CONTROL INSTALLED. M18960A


Industrial Combustion
Controls

70-6910 261
Thermostatic Radiator Valves and Actuators
Typical Installations

M3190 M4640
M4638

M4632

M12935

Pipe Size Capacity


Connection
Product Number Application (inch) DN Body Pattern (Cv) (Btu/hr-steam) Type
V110D1000 Precise and automatic control of room 1/2 in. DN15 Straight 4.6 Cv 127,000 Btu/hr Threaded
temperature in two-pipe systems by
V110D1008 modulating the flow of hot water or 3/4 in. DN20 Straight 5.8 Cv 162,000 Btu/hr Threaded
V110D1016 steam through high capacity heating 1 in. DN25 Straight 7.0 Cv 193,000 Btu/hr Threaded
units.
V110D1024 1 1/4 in. DN32 Straight 8 Cv 193,000 Btu/hr Threaded
V110D5001 1/2 in. DN15 Straight 4.6 Cv 127,000 Btu/hr Sweat
V110D5009 3/4 in. DN20 Straight 5.8 Cv 162,000 Btu/hr Sweat
V110D5017 1 in. DN25 Straight 7.0 Cv 193,000 Btu/hr Sweat
V110E1004 Precise and automatic control of room 1/2 in. DN15 Angle 4.6 Cv 127,000 Btu/hr Threaded
temperature in two-pipe systems by
V110E1012 modulating the flow of hot water or 3/4 in. DN20 Angle 5.8 Cv 162,000 Btu/hr Threaded
V110E1020 steam through high capacity heating 1 in. DN25 Angle 7.0 Cv 193,000 Btu/hr Threaded
units when used with T104
V110E1028 Thermostatic Actuators 1 1/4 in. DN32 Angle 8 Cv 193,000 Btu/hr Threaded
V110E5005 1/2 in. DN15 Angle 4.6 Cv 127,000 Btu/hr Sweat
V110E5013 3/4 in. DN20 Angle 5.8 Cv 162,000 Btu/hr Sweat
V110F1002 1/2 in. DN15 Horizontal Angle 4.6 Cv 127,000 Btu/hr Threaded
V110F1010 3/4 in. DN20 Horizontal Angle 5.8 Cv 162,000 Btu/hr Threaded
V110F1018 1 in. DN25 Horizontal Angle 7.0 Cv 193,000 Btu/hr Threaded
V110F1026 1 1/4 in. DN32 Horizontal Angle 8 Cv 193,000 Btu/hr Threaded
V110F5003 1/2 in. DN15 Horizontal Angle 4.6 Cv 127,000 Btu/hr Sweat
V110F5011 3/4 in. DN20 Horizontal Angle 5.8 Cv 162,000 Btu/hr Sweat

262 customer.honeywell.com 70-6910


Thermostatic Radiator Valves and Actuators
V200; V2000 Series Standard Capacity Thermostatic Radiator Valve

Controls
Home
Body
One-Pipe Steam Thermostatic Radiator Valves - Allow automatic
temperature control in one-pipe steam or hot water systems for
free standing radiators, convectors and other heating units with
standard capacity requirements. Provide comfort and energy
savings.

Indoor Air Quality


• Continually monitors and adjusts room temperature for consistent
comfort and relief from under-heating and overheating.
• Adjustable balancing cartridge design made from resilient material
V2040A, V2040E (EPDM), ensures tight shut-off on steam and hot water systems.
V200LD • Nickel plated brass casted body.
• Replaceable cartridge for easy service with service tool.
• Controls include valve body, steam air vent.
• Used with T100 set point and capillary actuators.
• No electrical connection required for non-electric actuators.

Combustion Controls
• Normally open without control mounted.

Residential
V2040D

V2040E

Hydronic Controls
Dimensions in inches (millimeters)
V2040D (Straight Body)
V200LD (Straight Body)

1 B MAX.
B MAX.

Controls
Water
A
A
A B MAX
A B MAX PIPE SIZE IN. (MM) 1 IN. (MM)
PIPE SIZE IN. (MM) 1 IN. (MM)

Building Automation
1/2 INCH 3-3/4 (95) 4-1/6 (104)
1/2 INCH 2-5/8 (66) 4-1/16 (104)
3/4 INCH 4-3/16 (106) 4-1/6 (104)
3/4 INCH 2-15/16 (74) 4-1/16 (104)
1 INCH 4-1/2 (114) 4-1/2 (114)
1 B MAX DIMENSION IS WITH T100A CONTROL INSTALLED.
M12933C 1 B MAX DIMENSION IS WITH T100A CONTROL INSTALLED.
M12930D

V2040A (Horizontal Angle Body) V2040E (Angle Body)

Components
Commercial
B MAX.
C

B MAX. A C
Pneumatic Controls

A B MAX C
PIPE SIZE IN. (MM) 1 IN. (MM) IN. (MM)
A
1/2 INCH 2-1/8 (54) 4-1/2 (115) 1-1/8 (29)

3/4 INCH 2-1/2 (64) 5-3/16 (132) 1-3/16 (31) A B MAX C


PIPE SIZE IN. (MM) 1 IN. (MM) IN. (MM)
1 INCH 2-15/16 (74) 5-3/16 (132) 1-7/16 (37)
1/2 INCH 2-5/16 (58) 3-13/16 (97) 1 (25)
1 B MAX DIMENSION IS WITH T100A CONTROL INSTALLED. M12932C
Industrial Combustion

3/4 INCH 2-5/8 (66) 3-13/16 (97) 1-1/8 (29)

1 INCH 2-15/16 (74) 4-5/16 (110) 1-5/16 (34)


Controls

1 B MAX DIMENSION IS WITH T100A CONTROL INSTALLED.


M12931D

70-6910 263
Thermostatic Radiator Valves and Actuators
Typical Installations

M4640
M3190
M4638

M4632

Capacity: Standard Pressure Ratings (Hot Water): 150 psi maximum


Materials (Body): Nickel Plated Bronze (1034 kPa maximum)
Differential Pressure Rating: Pressure Ratings (Steam): 15 psi maximum (103 kPa)
With T100 or T200: 15 psi (103 kPa) Temperature Rating: 248 F Maximum (120 C Maximum)
With MV100: 36 psi (248 kPa) Cartridge Change Tool: Yes - Use VA8200A001
For low noise: 3 psi (20 kPa)

Pipe Size Outlet Capacity


Connection
Product Number Application Body Pattern (inch) DN Type (Cv) (Btu/hr-steam) Used With
V200LDSL15 For baseboards and other Straight 1/2 in. DN15 Sweat both 2.5 Cv 59,100 Btu/hr T100
installations with copper ends, no union
tubing.
V200LDSL20 Straight 3/4 in. DN20 Sweat both 2.7 Cv 63,800 Btu/hr T100
ends, no union
V2040ASL15 Replaces most manual Horizontal Angle 1/2 in. DN15 Threaded 2.5 Cv 59,100 Btu/hr T100A, M and V controls
valves with minimum piping to conform to horizontal
changes. mounting requirements
V2040ASL20 Horizontal Angle 3/4 in. DN20 Threaded 2.7 Cv 63,800 Btu/hr T100A, M and V controls
to conform to horizontal
mounting requirements
V2040ASL25 Horizontal Angle 1 in. DN25 Threaded 2.7 Cv 70,500 Btu/hr T100A, M and V controls
to conform to horizontal
mounting requirements
V2040DSL15 Especially suited for base Straight 1/2 in. DN15 Threaded 2.5 Cv 59,100 Btu/hr —
boards and straight runs
V2040DSL20 where manual valves were Straight 3/4 in. DN20 Threaded 2.7 Cv 63,800 Btu/hr —
V2040DSL25 not originally installed. Straight 1 in. DN25 Threaded 2.7 Cv 70,500 Btu/hr —
V2040ESL15 Use where installation Angle 1/2 in. DN15 Threaded 2.5 Cv 59,100 Btu/hr T100B; T100C; T100F
space is limited
V2040ESL20 Angle 3/4 in. DN20 Threaded 2.7 Cv 63,800 Btu/hr T100B; T100C; T100F
V2040ESL25 Angle 1 in. DN25 Threaded 2.7 Cv 70,500 Btu/hr T100B; T100C; T100F
V2043ASL15 Replaces most manual Horizontal Angle 1/2 in. DN15 Sweat 2.5 Cv 59,100 Btu/hr T100A, M and V controls
valves with minimum piping to conform to horizontal
changes. mounting requirements
V2043ASL20 Horizontal Angle 3/4 in. DN20 Sweat 2.7 Cv 63,800 Btu/hr T100A, M and V controls
to conform to horizontal
mounting requirements
V2043DSL15 For baseboards and other Straight 1/2 in. DN15 Sweat both 2.5 Cv 59,100 Btu/hr T100
installations with copper ends, no union
tubing.
V2043DSL20 Especially suited for base Straight 3/4 in. DN20 Sweat 2.7 Cv 63,800 Btu/hr —
boards and straight runs
where manual valves were
not originally installed.
V2043ESL15 Use where installation Angle 1/2 in. DN15 Sweat 2.5 Cv 59,100 Btu/hr T100B; T100C; T100F
space is limited
V2043ESL20 Angle 3/4 in. DN20 Sweat 2.7 Cv 63,800 Btu/hr T100B; T100C; T100F

264 customer.honeywell.com 70-6910


Thermostatic Radiator Valves and Actuators
V2000 Series Valve Bodies Cross Reference to V100 Series

Controls
Home
Use T100 Actuators With New V2000 Series Valve Bodies

V2000 Series V100 Series


Replacement Product Product Description
V2040DSL15 V100D 1056 1/2 in. TRV Straight Body, Female NPT Inlet, Male NPT Tailpiece Outlet

Indoor Air Quality


V2040DSL20 V100D 1064 3/4 in. TRV Straight Body, Female NPT Inlet, Male NPT Tailpiece Outlet
V2040DSL25 V100D 1072 1in. TRV Straight Body, Female NPT Inlet, Male NPT Tailpiece Outlet
V2043DSL15 V100D 5057 1/2 in. TRV Straight Body, Female NPT Inlet, Sweat Tailpiece Outlet
V2043DSL20 V100D 5065 3/4 in. TRV Straight Body, Female NPT Inlet, Sweat Tailpiece Outlet
V2040ESL15 V100E 1055 1/2 in. TRV Vertical Body, Female NPT Inlet, Male NPT Tailpiece Outlet
V2040ESL20 V100E 1063 3/4 in. TRV Vertical Body, Female NPT Inlet, Male NPT Tailpiece Outlet

Combustion Controls
V2040ESL25 V100E 1071 1 in. TRV Vertical Body, Female NPT Inlet, Male NPT Tailpiece Outlet

Residential
V2043ESL15 V100E 5056 1/2 in. TRV Vertical Body, Female NPT Inlet, Sweat Tailpiece Outlet
V2043ESL20 V100E 5064 3/4 in. TRV Vertical Body, Female NPT Inlet, Sweat Tailpiece Outlet
V2040ASL15 V100F 1054 1/2 in. TRV Horizontal, Female NPT Inlet, Male NPT Tailpiece Outlet
V2040ASL20 V100F 1062 3/4 in. TRV Horizontal, Female NPT Inlet, Male NPT Tailpiece Outlet
V2040ASL25 V100F 1070 1” TRV Horizontal, Female NPT Inlet, Male NPT Tailpiece Outlet
V2043ASL15 V100F 5055 1/2 in. TRV Horizontal Body, Female NPT Inlet, Sweat Tailpiece Outlet

Hydronic Controls
V2043ASL20 V100F 5063 3/4 in. TRV Horizontal Body, Female NPT Inlet, Sweat Tailpiece Outlet
V200LDSL15 V100G 5054 1/2 in. TRV Straight Body, Sweat Inlet, Sweat Outlet No Tailpiece
V200LDSL20 V100G 5062 3/4 in. TRV Straight Body, Sweat Inlet, Sweat Outlet No Tailpiece
V2042HSL10 V100P 1046 1/8 in. TRV (1/2 in. Body With 1/8 in. Adapter) Male NPT Inlet, Female NPT Outlet. One Pipe Steam
1/8 in. TRV (1/2 in. Body With 1/8 in. Adapter) Male NPT Inlet, Female NPT Outlet. One Pipe Steam Includes
V2043HSL10 Y100P 1001 SA123A1003
VS1200SL01 Replacement Cartridge New V2000 Series
VA8200A001 Cartridge Service Tool V2000 Series Bodies

Controls
Water
Building Automation
Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 265
Thermostatic Radiator Valves and Actuators
V2042H; V2043H One-pipe Steam Thermostatic Radiator Valve
One-Pipe Steam Thermostatic Radiator Valves - Allow automatic
temperature control in one-pipe steam or hot water systems for
free standing radiators, convectors and other heating units with
standard capacity requirements. Provide comfort and energy
savings.
• Continually monitors and adjusts room temperature for consistent
comfort and relief from under-heating and overheating.
• Adjustable balancing cartridge design made from resilient material
(EPDM), ensures tight shut-off on steam and hot water systems.
• Nickel plated brass casted body.
• Replaceable cartridge for easy service with service tool.
• Controls include valve body, steam air vent.
• Used with T100 set point and capillary actuators.
• No electrical connection required for non-electric actuators.
• Normally open without control mounted.

Dimensions in inches (millimeters) Typical Installations

V2042H (Body)/V2043H (Body with Vent)

V2042H (VALVE BODY)


V2043H (VALVE BODY
PLUS AIR VENT)

T100A

B MAX. A
M11752B

C
2
5
6 0

4
5
0
A B MAX C
PIPE SIZE IN. (MM) 1 IN. (MM) 2 IN. (MM) M3236

3/8 INCH 1-11/16 (43) 3-13/16 (97) 1-3/16 (31)

1 B MAX DIMENSION IS WITH T100A CONTROL INSTALLED.


M3237

2 C DIMENSION IS WITHOUT THE STEAM/AIR VENT INSTALLED.


M17016B Capacity: Standard
Materials (Body): Nickel Plated Bronze
Differential Pressure Rating:
With T100 or T200: 15 psi (103 kPa)
With MV100: 36 psi (248 kPa)
For low noise: 3 psi (20 kPa)
Pressure Ratings (Steam): 15 psi maximum (103 kPa)
Temperature Rating: 248 F Maximum (120 C Maximum)
Body Pattern: Angle
Cartridge Change Tool: Yes - Use VA8200A001

Pipe Size Connection


Product Number Application (inch) Type Description Includes Used With
V2042HSL10 Angle pattern valve body for one pipe 1/8 in. Threaded One-pipe Steam 1/8 in. Radiator — T100
steam systems valve
V2043HSL10 Thermostatic Radiator Valve Pack. 1/8 in. NPT One Pipe Steam Thermostatic V2042HSL10 —
Includes V2042HSL10 body plus Radiator valve and air vent pack plus steam/air
steam/air vent. Use for one pipe steam vent
applications.

266 customer.honeywell.com 70-6910


Thermostatic Radiator Valves and Actuators
V2000 Series Thermostatic Radiator Valve Accessories

Controls
Home
Materials (Body): Bronze
Cartridge Change Tool: VA8200A001

Indoor Air Quality


V2000 Series Cartridge Balancing Procedure Step 1 V2000 Series Cartridge Balancing Procedure Step 3

Combustion Controls
Residential
M22689

V2000 Series Cartridge Balancing Procedure Step 4

Hydronic Controls
V2000 Series Cartridge Balancing Procedure Step 2

M22690

Controls
Water
M22688

Product Number Application Description Used With

Building Automation
VS1200SL01 Accessory or Replacement Part Replacement cartridge for NEW V2000 (adjustable cartridge) T100

Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 267
Thermostatic Radiator Valves and Actuators
MT100; MT110 Cartridge Changing Tool
The MT110 Valve Cartridge Changing Tool enables the user to
remove, and clean or replace the valve cartridge while the valve
remains pressurized. Boiler shutdown is not required.
• MT110 for V110 Series valves.

Remove control and loosen valve cartridge slightly. Open shut-off on drain cock, removing excess water and steam
from chamber.

B
B
A
A

M16274
M16275

Tighten Cartridge Changer to valve body and close off drain cock. Unscrew end cap and remove cartridge from chamber. Clean or
replace cartridge.

D
A
A

M16273 B
C M16276

Product Number Application Type Description Comments Used With


MT100L1023 Tool to remove T100M tamper resistant direct mount control from valve body. Actuator Removal Tool — V100
MT110C1011 Cartridge changing tool, in service, in line, under pressure for V110 series Cartridge Changing Tool for — V100
valve. in-line service of V110 valves
MT110D1019 Socket to remove or replace cartridges on V110D, E, F series valves; use in Cartridge Changing tool For CA110C —
combination with MT110C1011 for pre-loosening and final tightening of Cartridge
cartridge. Fits 3/8 in. socket driver.

Thermostatic Valve Accessories


Product Number Description Used With
CA100B1008 Replacement cartridge for old style V100 (metal cartridge body) V100 Series;
CA110C1007 Replacement Cartridge for V110 V110 Series;

268 customer.honeywell.com 70-6910


Thermostatic Radiator Valves and Actuators
T100 Standard Capacity Thermostatic Radiator Actuators

Controls
Home
Allow automatic temperature control in two-pipe steam or hot
water systems for free standing radiators, convectors, and other
heating units with standard capacity requirements. Provide
comfort and energy savings at affordable prices.
• Continually monitor and adjust room temperature for consistent
comfort and relief from under-heating and overheating.
• Valve seat disc, which is made of resilient material (EPDM), ensures

Indoor Air Quality


tight shutoff on steam or hot water systems.
• Nickel-plated brass casted body with working parts in cartridge insert
for ease of service.
• Controls include sensor, setpoint dial and valve actuator;
components may be integral or connected by capillary tubes.
• Require no electrical connections.
• All working parts are replaceable using service tool (MT100C1016)
while valve remains in service, in-line, under pressure.
• Valves normally open without control mounted.

Combustion Controls
• Valves may also be used with MV100 Electric Zone Valve Actuator.

Residential
Dimensions in inches (millimeters)
T100B

Hydronic Controls
T100A T100M
CAPILLARY TUBE LENGTH
2-1/8 (54)
TOP 6-1/2 FT (2m) OR 16 FT. (5m)
TOP

1-13/16
2-5/32 (46)
(55)
2 2
(50) (50)

2-31/32 (75)

Controls
M12926

Water
1 (25) T100C
2-1/8 (54)
CAPILLARY TUBE LENGTH 2-1/8 (54)
4-1/2 FT (1.4 m)

Building Automation
3
(77) 1-13/16
2-5/32 (46)
(55)

3-5/16
(84)
MAX. 2-31/32 (75)

CAPILLARY TUBE
M12929 LENGTH 4-1/2 FT (1.4 m)

Components
Commercial
M12925A M12927

T100F 2-1/8 (54)

2 (50)
CAPILLARY TUBE
LENGTH 6-1/2 FT (2 m)
Pneumatic Controls

3-5/16
(84)
MAX.

M12928
Industrial Combustion
Controls

70-6910 269
Thermostatic Radiator Valves and Actuators
Typical Installations

M3190
M4638

M4631
M12937

M12935

Application: Standard Capacity Thermostatic Radiator Actuator


Used With Valve: V100, V2000
Collar Diameter: 1 3/16 in. (30 mm)

Capillary Temperature
Length Range Sensor Setpoint
(Integral or (Integral or Used
Product Number Application Type (ft) (m) (F) (C) Remote) Remote) Comments With
T1002W0NA A self-contained control with sensor, setpoint — — 43 F to 6 C to Integral Integral Adjustable V100,
dial and valve actuator in one unit. Mounts 79 F 26 C Limits V2000
horizontal. Not for use inside enclosures or
where airflow around sensor is restricted.
Adjustable limits.
T100B1035 A control with combined remote setpoint and 6 1/2 ft 2m 48 F to 9 C to Remote Remote — V100,
sensor mounted on wall. Connected by a 79 F 26 C V2000
capillary tube to an actuator, which is
T100B1043 mounted on the valve body. 16 ft. 5m 48 F to 9 C to Remote Remote — V100,
79 F 26 C V2000
T100C1026 A control with remote setpoint and sensor Two Two 48 F to 9 C to Remote Remote — V100,
mounted with setpoint dial on outside of 4 1/2 ft. 1.4 m 79 F 26 C V2000
heating cabinet; sensor mounted beneath
heating coils in cold air return. Dual capillary.
T100F1395 A control with remote temperature sensing 6 ft. 8 in. 2 m 43 F to 6 C to Integral Integral Adjustable V100,
and integral set point. Adjustable limits. 79 F 26 C Limits V2000
T100M2056 A self-contained control with sensor, setpoint — — 43 F to 6 C to Integral Integral Tamper V100,
dial and actuator in one unit. Use where 79 F 26 C Resistant, V2000
increased durability, tamper resistance and Adjustable
limited adjustment range are desired. Limits
Horizontal mount. Locks onto valve body. Not
for enclosures.

270 customer.honeywell.com 70-6910


Thermostatic Radiator Valves and Actuators
T104 High Capacity Thermostatic Radiator Valve Actuators

Controls
Home
Indoor Air Quality
T104A
T104V

Combustion Controls
T104B T104C T104F

Residential
Provide precise and automatic control of room temperature in two- • Valve seat disc, which is made of resilient material (EPDM), ensures
pipe systems by modulating the flow of hot water or steam through tight shutoff on steam or hot water systems.
free-standing radiators, convectors and other heating units with • Nickel-plated bronze casted body with working parts in cartridge
high capacity requirements. insert for ease of service.
• Continually monitor and adjust room temperature for consistent • Controls include sensor, setpoint dial and valve actuator;
comfort and relief from under-heating and overheating. components may be integral or connected by capillary tubes.
• Designed with the higher capacity normally required by North • Require no electrical connections.
American heating systems. • Meet ASHRAE Standard 102-1989.

Hydronic Controls
• 40 mm collar diameter.

Dimensions in inches (millimeters)

3 5/16 (84) MAX.


TOP

2-1/8
(54) 2 1/8 (54)
2 1/8
(54)

Controls
Water
1 (25)
3 5/16
(84)
2 (50) M9708B MAX.

CAPILLARY TUBE LENGTH


2-1/8 (54)
6 FT. 6 IN. (2 m) OR 16 FT. (5 m)

Building Automation
M9731

1-13/16
2-5/32 (46)
(55) T104V
2-31/32 (75) 4
M3208A
2
(51) H

Components
CAPILLARY TUBE LENGTH

Commercial
2-1/8 (54)
4 FT. 6 IN. (1.37 m)

1-13/16
2-5/32 (46)
(55)
Pneumatic Controls

2-31/32 (75)

CAPILLARY TUBE 3
LENGTH 4 FT. 6 IN. (1.37 m) 3
8
(86)

M3221C
Industrial Combustion
Controls

M3215A

70-6910 271
Thermostatic Radiator Valves and Actuators
Application: High Capacity Thermostatic Radiator Actuator
Used With Valve: V110
Collar Diameter: 1 19/32 in. (40 mm)

Capillary Temperature
Length Range Sensor Setpoint
(Integral or (Integral or
Product Number Application Type (ft) (m) (F) (C) Remote) Remote) Comments Used With
T104A1040 Self-contained controller with sensor, — — 43 F to 6 C to Integral Integral Adjustable V110
setpoint dial and valve actuator in one 79 F 26 C Limits
unit. Adjustable limits. Mount horizontal.
Not for use inside enclosures or in
locations with restricted airflow around
sensor. For V110 valves.
T104B1038 Controller with combined remote 6 ft. 8 in. 2 m 48 F to 9 C to Remote Remote — V110
setpoint and sensor mounted on a wall. 79 F 26 C
Setpoint/sensor connect with a capillary
T104B1046 tube to an actuator, which mounts on 16 ft. 4.9 m 48 F to 9 C to Remote Remote — V110
the valve body. For V110 valves. 79 F 26 C

T104C1036 Controller with remote setpoint and Two Two 48 F to 9 C to Remote Remote — V110
sensor normally mounted with setpoint 4 1/2 ft. 1.4 m 79 F 26 C
dial mounted on outside cabinet or
enclosure; sensor mounted beneath
heating coils in cold air return. Double
capillaries. For V110 valves.
T104F1512 Thermostatic radiator valve controller 6 ft. 8 in. 2 m 43 F to 6 C to Remote Integral Adjustable V110
for use with V110 series valves. With 79 F 26 C Limits
remote temperature sensing and
integral set point. Adjustable limits.
T104V1422 Self-contained controller with sensor, — — 43 F to 6 C to Integral Integral Vandal Proof V110
setpoint dial and valve actuator in one 79 F 26 C
unit. Locks to valve body. Rugged
design. Adjustable setpoint under
locking cap. Factory set at 68 F (20 C).
Mounts horizontal. Not for use in
enclosures. For V110 valves.

T104 Thermostatic Radiator Valves Parts and Accessories


Product Number Description Used With
G111B1053 Bulb guard to protect remote temperature sensors on T104C and T104F controls only T104F; T104C
P110V1003 Replacement Locking Ring for T104V1422 only (package of 5) T104V1422

272 customer.honeywell.com 70-6910


Commercial Air Eliminators
SuperVent®—The Best Commercial Air Eliminator.

Controls
Home
Removes All Trapped Air, Micro Bubbles and Dirt from Heating,
Cooling and Domestic Water Systems.
Conventional automatic air vents installed in Hydronic heating
systems can leak and cause inefficient system operation. To
effectively eliminate air from the system without bleeding, air

Indoor Air Quality


bubbles ned to be vented. The NEW Honeywell SuperVent purges
air through a no clog vent assembly that controls dirt and debris to
minimize air vent fouling.
• No clog vent.
• Dirt and Debris resistant.
• 360 degree adjustable collar ring for installation flexibility.
• Stainless steel concentrator which eliminates gurgling noise.
• Bronze body for rigid construction.
• Threaded connections.

Combustion Controls
Application: Commercial Zoning for hot water heating or chilled water

Residential
air conditioning systems, fan coil units or indirect water heater service.
Materials (Body): Bronze
Maximum Operating Temperature: 240 F (115 C)
Maximum Operating Pressure: 150 psi (1034 kPa)
Dimensions in inches (millimeters)

THREADED FLANGED FLANGED CLEANABLE

Hydronic Controls
1/2 NPT 1/2 NPT 1/2 NPT

DIMENSIONS (INCHES)
VALVE SIZE A B C
A A A
2 INCH 11-1/16 6-3/16 10-1/8
2-1/2 INCH 11-1/16 6-3/16 10-1/8
3 INCH 15-5/8 7-15/16 15-1/2
4 INCH 15-5/8 7-15/16 15-1/2

Controls
5 INCH 21 11-1/8 24

Water
B B B
6 INCH 21 11-1/8 24
8 INCH 25-13/16 12-15/16 30

M23261B
3/4 NPT 3/4 NPT 3/4 NPT

C C C

Building Automation
Maximum Diameter Capacity Weight
Product
Number Size (inch) (mm) Connection Type (Cv) (lb) (kg)
PV200F 2 in. 5 5/8 in. 142.2 mm Flanged 95 Cv 31.5 lb 14.29 kg
PV200FC 2 in. 10 in. 254 mm Flanged Cleanable 95 Cv 64 lb 29.03 kg
PV200T 2 in. 5 5/8 in. 142.2 mm NPT 95 Cv 22 lb 9.98 kg
PV250F 2 1/2 in. 5 5/8 in. 142.2 mm Flanged 140 Cv 37 lb 16.78 kg

Components
Commercial
PV250FC 2 1/2 in. 10 in. 254 mm Flanged Cleanable 140 Cv 70 lb 31.75 kg
PV250T 2 1/2 in. 5 5/8 in. 142.2 mm NPT 140 Cv 23 lb 10.43 kg
PV300F 3 in. 8 5/8 in. 218.4 mm Flanged 215 Cv 66 lb 29.94 kg
PV300FC 3 in. 13 1/2 in. 342.9 mm Flanged Cleanable 215 Cv 137 lb 62.14 kg
PV300T 3 in. 8 5/8 in. 218.4 mm NPT 215 Cv 50 lb 22.68 kg
PV400F 4 in. 8 5/8 in. 218.4 mm Flanged 360 Cv 78.5 lb 35.61 kg
Pneumatic Controls

PV400FC 4 in. 13 1/2 in. 342.9 mm Flanged Cleanable 360 Cv 150 lb 68.04 kg
PV400T 4 in. 8 5/8 in. 218.4 mm NPT 360 Cv 52.5 lb 23.81 kg
PV500F 5 in. 12 13/16 in. 325.1 mm Flanged 590 Cv 147 lb 66.68 kg
PV500FC 5 in. 19 in. 482.6 mm Flanged Cleanable 590 Cv 310 lb 140.62 kg
PV600F 6 in. 12 13/16 in. 325.1 mm Flanged 860 Cv 158 lb 71.67 kg
PV600FC 6 in. 19 in. 482.6 mm Flanged Cleanable 860 Cv 320 lb 145.15 kg
Industrial Combustion

PV800F 8 in. 16 in. 406.4 mm Flanged 1500 Cv 254 lb 115.21 kg


Controls

PV800FC 8 in. 23 1/2 in. 596.9 mm Flanged Cleanable 1500 Cv 516 lb 234.06 kg

70-6910 273
Commercial Expansion Tanks
Expansion Tank Sizing based on BTU’s
Boiler Type of Radiation
Net Output in 1000’s of Finned Tube Baseboard Convectors or
BTU/Hr or Radiant Panel Unit Heaters Radiators Cast Iron Baseboard Cast Iron
MBH Use Model Use Model Use Model Use Model
25 TK300-15 TK300-15 TK300-15 TK300-15
50 TK300-15 TK300-15 TK300-30 TK300-30
75 TK300-30 TK300-30 TK300-30 TK300-60
100 TK300-30 TK300-30 TK300-60 TK300-60
125 TK300-30 TK300-60 TK300-60 TK300-90
150 TK300-30 TK300-60 TK300-90 TK300-90
175 TK300-60 TK300-60 XPS-030V XPS-030V
200 TK300-60 TK300-60 XPS-030V XPS-030V
250 TK300-60 TK300-90 XPS-030V XPS-040V
300 TK300-90 XPS-030V XPS-030V XPS-040V
350 XPS-030V XPS-030V XPS-040V XPS-060V
400 XPS-030V XPS-040V XPS-040V XPS-060V

Expansion Tanks—Domestic Hot Water Systems- Large Capacity


The Honeywell Thermal Expansion Absorber is a welded,
pressurized expansions tank with a butyl diaphragm to control
excess pressure in potable hot water systems. The Thermal
Expansion Tanks controls pressure build-up in the system,
eliminates relief valve spillage, protects fixtures and extends water
heater life.
• Heavy Duty butyl rubber diaphragm (FDA Approved) isolates water
from air.
• Polypropylene liner, 100% non-metallic, non-corrosive water
reservoir.
• Prevents water hammer.
• Maintenance free.
• Protects water heater from harmful pressure cycling.
• Allows storage of expanded water with controlled increase in
systems pressures.

Maximum Operating Temperature: 240 F (115 C)


Maximum Operating Pressure: 150 psi (1034 kPa)
Precharge: 40 psi
Materials:
Shell: Steel
Connection: Bronze
Bladder: Butyl
Comments: Potable

Con- Maximum
nection Acceptance
Size Diameter Height Volume Volume Weight
Product Connection
Number (inch) Type (mm) (inch) (mm) (inch) (L) (gal) (L) (gal) (kg) (lb)
TX-451 2 in. Female NPT 762 mm 30 in. 1892 mm 74 1/2 in. 598.8 L 158.0 gal 389.86 L 103 gal 283.95 kg 626 lb
TX-452 2 in. Female NPT 914.4 mm 30 in. 2349.5 mm 92 1/2 in. 798.64 L 211.0 gal 518.55 L 137 gal 344.74 kg 760 lb
TX-453 3 in. Female NPT 914.4 mm 36 in. 2175 mm 85 5/8 in. 999.24 L 264.0 gal 651.02 L 172 gal 367.42 kg 810 lb
TX-454 3 in. Female NPT 914.4 mm 36 in. 2490 mm 98 in. 1199.85 L 317.0 gal 779.71 L 206 gal 414.59 kg 914 lb
TX-455 3 in. Female NPT 914.4 mm 36 in. 2803.5 mm 110 3/8 in. 1400.45 L 370.0 gal 912.19 L 241 gal 461.76 kg 1018 lb
TX-456 3 in. Female NPT 1219.2 mm 48 in. 2080 mm 81 7/8 in. 1597.27 L 422.0 gal 1040.88 L 275 gal 750.71 kg 1655 lb
TX-457 3 in. Female NPT 1219.2 mm 48 in. 2432 mm 95 3/4 in. 1998.48 L 528.0 gal 1302.04 L 344 gal 873.18 kg 1925 lb

274 customer.honeywell.com 70-6910


Commercial Expansion Tanks
TAX Series Expansion Tanks - Commercial Usage

Controls
Home
TAX Series (commercial) Expansion Tanks are designed to absorb
hot water expansion in closed heating systems. TAX tanks are
used in large installations. They are equipped with butyl
diaphragms to separate the air from the system water (glycol). The
tanks are a welded, not clamped, design. Pre-pressurized at 12 psi,
the tank keeps fluids circulating and maintains minimum system
pressure. Honeywell tanks resist waterlogging, loss of pressure

Indoor Air Quality


through relief valve spills, and loss of BTUs.
• ASME construction: Horizontal TAX Series tanks.

Maximum Operating Temperature: 240 F (115 C)


Maximum Operating Pressure: 125 psi (862 kPa)
Precharge: 12 psi
Materials: steel shell, heavy duty butyl diaphragm
Comments: ASME Construction

Combustion Controls
Con- Maximum

Residential
nection Acceptance
Size Diameter Height Volume Volume Weight
Product
Number (inch) (inch) (mm) (inch) (mm) (gal) (L) (gal) (L) (lb) (kg)
TAX-15 1/2 in. 12 in. 304.8 mm 19 in. 483 mm 7.8 gal 29.6 L 2.5 gal 9.5 L 46 lb 20.9 kg
TAX-20 1/2 in. 12 in. 304.8 mm 25 3/4 in. 654 mm 10.9 gal 40.2 L 2.5 gal 9.5 L 59 lb 26.8 kg
TAX-40 1/2 in. 16 1/4 in. 412.7 mm 29 1/8 in. 740 mm 21.7 gal 82.2 L 11.3 gal 42.8 L 114 lb 52.7 kg

Hydronic Controls
TAX-60 1/2 in. 16 1/4 in. 412.7 mm 42 1/2 in. 1079.5 mm 33.6 gal 127.3 L 11.3 gal 42.8 L 139 lb 63.2 kg
TAX-80 1/2 in. 16 1/4 in. 412.7 mm 55 1/4 in. 1403 in. 44.4 gal 168.3 L 22.6 gal 85.6 L 196 lb 89.1 kg
TAX-100 1/2 in. 16 1/4 in. 412.7 mm 68 1/4 in. 1734 mm 55.7 gal 211 L 22.6 gal 85.6 L 231 lb 105 kg
TAX-120 1 in. 24 in. 609.6 mm 40 1/4 in. 1022 mm 68 gal 257.7 L 34 gal 128.9 L 233 lb 105.9 kg
TAX-144 1 in. 24 in. 609.6 mm 45 1/4 in. 1146 mm 77.0 gal 291.8 L 34 gal 128.9 L 256 lb 116.4 kg
TAX-180 1 in. 24 in. 609.6 mm 52 1/2 in. 1333.5 mm 90 gal 341.1 L 34 gal 128.9 L 286 lb 130 kg
TAX-200 1 in. 24 in. 609.6 mm 63 in. 1600 mm 110 gal 416.9 L 34 gal 128.9 L 326 lb 148.2 kg
TAX-240 1 in. 30 in. 762 mm 49 1/8 in. 1247.8 mm 132.0 gal 500.3 L 46 gal 174.3 L 435 lb 207.3 kg

Controls
Water
TAX-260 1 in. 30 in. 762 mm 49 1/8 in. 1247.8 mm 158.0 gal 500.3 L 56 gal 174.3 L 435 lb 207.3 kg
TAX-280 1 in. 30 in. 762 mm 49 1/8 in. 1247.8 mm 211.0 gal 500.3 L 84 gal 174.3 L 435 lb 207.3 kg

Building Automation
Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 275
Commercial Expansion Tanks
TAXV Series Expansion Tank- Commercial Usage
TAX Series (commercial) Expansion Tanks are designed to absorb
hot water expansion in closed heating systems. TAX tanks are
used in large installations. They are equipped with butyl
diaphragms to separate the air from the system water (glycol). The
tanks are a welded, not clamped, design. Pre-pressurized at 12 psi,
the tank keeps fluids circulating and maintains minimum system
pressure. Honeywell tanks resist waterlogging, loss of pressure
through relief valve spills, and loss of BTUs.
• ASME construction: Horizontal TAX Series tanks.
Maximum Operating Temperature: 240 F (115 C)
Maximum Operating Pressure: 125 psi (862 kPa)
Precharge: 12 psi
Materials: steel shell, heavy duty butyl diaphragm
Comments: ASME Construction

Con- Maximum
nection Acceptance
Size Diameter Height Volume Volume Weight
Product
Number (inch) (inch) (mm) (inch) (mm) (gal) (L) (gal) (L) (lb) (kg)
TAXV-015 1/2 in. 12 in. 304.8 mm 19 1/4 in. 489 mm 7.8 gal 29.6 L 2.5 gal 9.5 L 48 lb 21.8 kg
TAXV-020 1/2 in. 12 in. 304.8 mm 26 in. 660 mm 10.9 gal 40.2 L 2.5 gal 9.5 L 61 lb 27.7 kg
TAXV-040 1/2 in. 16 1/4 in. 412.7 mm 29 1/2 in. 749 mm 21.7 gal 82.2 L 11.3 gal 42.8 L 116 lb 52.7 kg
TAXV-060 1/2 in. 16 1/4 in. 412.7 mm 45 1/8 in. 1146 mm 33.6 gal 127.3 L 11.3 gal 42.8 L 145 lb 65.9 kg
TAXV-080 1/2 in. 16 1/4 in. 412.7 mm 56 in. 1422 mm 44.4 gal 168.3 L 22.6 gal 85.6 L 70 lb 89.1 kg
TAXV-100 1/2 in. 16 1/4 in. 412.7 mm 68 1/4 in. 1734 mm 55.7 gal 211 L 22.6 gal 85.6 L 231 lb 105 kg
TAXV-120 1 in. 24 in. 609.6 mm 44 1/4 in. 1124 mm 68 gal 257.7 L 34 gal 128.9 L 233 lb 105.9 kg
TAXV-144 1 in. 24 in. 609.6 mm 49 1/8 in. 1247.8 mm 77.0 gal 291.8 L 34 gal 128.9 L 256 lb 116.4 kg
TAXV-180 1 in. 24 in. 609.6 mm 56 1/2 in. 1435 mm 90 gal 341.1 L 34 gal 128.9 L 286 lb 130 kg
TAXV-200 1 in. 24 in. 609.6 mm 63 in. 1600 mm 110 gal 416.9 L 34 gal 128.9 L 326 lb 148.2 kg
TAXV-240 1 in. 30 in. 762 mm 49 1/8 in. 1368.4 mm 132.0 gal 500.3 L 46 gal 174.3 L 456 lb 207.3 kg
TAXV-260 1 in. 30 in. 762 mm 49 1/8 in. 1247.8 mm 158.0 gal 500.3 L 56 gal 174.3 L 435 lb 207.3 kg
TAXV-280 1 in. 30 in. 762 mm 49 1/8 in. 1247.8 mm 211.0 gal 500.3 L 84 gal 174.3 L 435 lb 207.3 kg

276 customer.honeywell.com 70-6910


Commercial Expansion Tanks
TL Series Expansion Tanks - Commercial Usage

Controls
Home
Expansion Tanks are designed to absorb hot water expansion in
closed heating systems. TL tanks are used in large installations.
They are equipped with butyl diaphragms to separate the air from
the system water (glycol). The tanks are a welded, not clamped,
design. Pre-pressurized at 12 psi, the tank keeps fluids circulating
and maintains minimum system pressure. Honeywell tanks resist
waterlogging, loss of pressure through relief valve spills, loss of

Indoor Air Quality


BTUs and reduce circulator running time. Use the super efficient
Honeywell SuperVent or air vents to remove air and micro-bubbles
from the system for maximum performance.

Maximum Operating Temperature: 240 F (115 C)


Maximum Operating Pressure: 125 psi (862 kPa)
Precharge: 12 psi
Materials: steel shell, heavy duty butyl diaphragm
Comments: Commercial

Combustion Controls
Residential
Con-
nection

Hydronic Controls
Size Diameter Height Volume Weight
Product
Number (inch) (inch) (mm) (inch) (mm) (gal) (L) (lb) (kg)
TL125-200-L 1 in. 24 in. 609.6 mm 38 3/8 in. 975 mm 53 gal 200.9 L 192 lb 88.6 kg
TL125-300-L 1 in. 24 in. 609.6 mm 52 3/8 in. 1330 mm 80.0 gal 303.2 L 238 lb 128.6 kg
TL125-400-L 1 in. 24 in. 609.6 mm 66 1/4 in. 1683 mm 106.0 gal 401.7 L 238 lb 128.6 kg
TL125-500-L 1 in. 24 in. 609.6 mm 80 1/4 in. 2038 mm 132.0 gal 500.3 L 328 lb 149 kg
TL125-600-L 1 1/2 in. 30 in. 762 mm 65 in. 1651 mm 158 gal 598.8 L 550 lb 250 kg
TL125-800-L 1 1/2 in. 30 in. 762 mm 83 in. 2108 mm 211 gal 799.7 L 680 lb 309 kg

Controls
Water
TL125-1000-L 1 1/2 in. 36 in. 914.4 mm 74 in. 1880 mm 264 gal 1000.6 L 760 lb 345.4 kg
TL125-1200-L 1 1/2 in. 36 in. 914.4 mm 88 1/4 in. 2241.5 mm 317 gal 1201.4 L 864 lb 392.7 kg
TL125-1400-L 1 1/2 in. 36 in. 914.4 mm 100 5/8 in. 2556 mm 370 gal 1402.3 L 968 lb 440 kg
TL125-1600-L 1 1/2 in. 48 in. 1219.2 mm 71 in. 1803 mm 422 gal 1561.4 L 1580 lb 718.2 kg
TL125-2000-L 1 1/2 in. 48 in. 1219.2 mm 85 in. 2159 mm 528 gal 2001.1 L 1810 lb 822.7 kg

Building Automation
TL175-200-L 1 in. 24 in. 609.6 mm 38 3/8 in. 975 mm 53 gal 200.9 L 283 lb 128.6 kg
TL175-300-L 1 in. 24 in. 609.6 mm 52 3/8 in. 1330 mm 80.0 gal 303.2 L 358 lb 162.7 kg
TL175-400-L 1 in. 24 in. 609.6 mm 66 1/4 in. 1683 mm 106.0 gal 401.7 L 435 lb 197.7 kg
TL175-500-L 1 in. 24 in. 609.6 mm 80 1/4 in. 2038 mm 132.0 gal 500.3 L 510 lb 231.8 kg
TL175-600-L 1 1/2 in. 30 in. 762 mm 65 in. 1651 mm 158 gal 598.8 L 611 lb 277.7 kg
TL175-800-L 1 1/2 in. 30 in. 762 mm 83 in. 2108 mm 211 gal 799.7 L 729 lb 331.4 kg
TL175-1000-L 1 1/2 in. 36 in. 914.4 mm 74 in. 1880 mm 264 gal 1000.6 L 910 lb 413.6 kg

Components
Commercial
TL175-1200-L 1 1/2 in. 36 in. 914.4 mm 88 1/4 in. 2241.5 mm 317 gal 1201.4 L 1033 lb 469.5 kg
TL175-1400-L 1 1/2 in. 36 in. 914.4 mm 100 5/8 in. 2556 mm 370 gal 1402.3 L 1169 lb 531.4 kg
TL175-1600-L 1 1/2 in. 48 in. 1219.2 mm 71 in. 1803 mm 422 gal 1561.4 L 2094 lb 951.2 kg
TL175-2000-L 1 1/2 in. 48 in. 1219.2 mm 85 in. 2159 mm 528 gal 2001.1 L 2386 lb 1084.5 kg
TL250-200-L 1 in. 24 in. 609.6 mm 38 3/8 in. 975 mm 53 gal 200.9 L 379 lb 189.5 kg
TL250-300-L 1 in. 24 in. 609.6 mm 52 3/8 in. 1330 mm 80.0 gal 303.2 L 494 lb 224.5 kg
Pneumatic Controls

TL250-400-L 1 in. 24 in. 609.6 mm 66 1/4 in. 1683 mm 106.0 gal 401.7 L 607 lb 275.9 kg
TL250-500-L 1 in. 24 in. 609.6 mm 80 1/4 in. 2038 mm 132.0 gal 500.3 L 720 lb 327.3 kg
TL250-600-L 1 1/2 in. 30 in. 762 mm 65 in. 1651 mm 158 gal 598.8 L 85.1 lb 386.8 kg
TL250-800-L 1 1/2 in. 30 in. 762 mm 83 in. 2108 mm 211 gal 799.7 L 1030 lb 468.2 kg
TL250-1000-L 1 1/2 in. 36 in. 914.4 mm 74 in. 1880 mm 264 gal 1000.6 L 1419 lb 645 kg
TL250-1200-L 1 1/2 in. 36 in. 914.4 mm 88 1/4 in. 2241.5 mm 317 gal 1201.4 L 1613 lb 733.2 kg
Industrial Combustion

TL250-1400-L 1 1/2 in. 36 in. 914.4 mm 100 5/8 in. 2556 mm 370 gal 1402.3 L 1808 lb 821.8 kg
Controls

TL250-1600-L 1 1/2 in. 48 in. 1219.2 mm 71 in. 1803 mm 422 gal 1561.4 L 2311 lb 1050.5 kg
TL250-2000-L 1 1/2 in. 48 in. 1219.2 mm 85 in. 2159 mm 528 gal 2001.1 L 2677 lb 1216.8 kg

70-6910 277
Commercial Expansion Tanks
TX Series Expansion Tanks—ASME Construction for Potable Water
The Honeywell Thermal Expansion Absorber is a welded,
pressurized expansion tank with a butyl diaphragm to control
excess pressure in potable hot water systems. The Thermal
Expansion Tank controls pressure build-up in the system,
eliminates relief valve spillage, protects fixtures and extends water
heater life.
• Heavy duty butyl rubber diaphragm (FDA approved) isolates water
from air.
• Polypropylene liner, 100% non-metallic, non-corrosive water
reservoir.
• Full size range: 2-528 gals., for all water heating volumes (ASME
available).
• Prevents water hammer.
• Maintenance free.
• Protects water heater from harmful pressure cycling.
• Allows storage of expanded water with no increase in system
pressures.

Maximum Operating Temperature200 F: (93 C)


Maximum Operating Pressure: 150 psi (1034 kPa)
Precharge: 40 psi
Materials:
Shell: Steel
Diaphragm: Butyl
Connection: Stainless Steel
Liner: Polypropylene
Comments: ASME Construction

Con- Maximum
nection Acceptance
Size Diameter Height Volume Volume Weight
Product Connection
Number (inch) Type (inch) (mm) (inch) (mm) (gal) (L) (gal) (L) (lb) (kg)
TX-5-C 3/4 in. Male NPT 10 in. 254.0 mm 10 3/8 in. 263.5 mm 2.0 gal 7.6 L 0.86 gal 3.26 L 21 lb 9.53 kg
TX-20V-C 3/4 in. Male NPT 24 in. 609.6 mm 47 3/4 in. 1213 mm 7.6 gal 28.8 L 3.2 gal 12.1 L 258 lb 117 kg
TX-30V-C 3/4 in. Male NPT 16 1/4 in. 412.8 mm 17 1/4 in. 438 mm 12.5 gal 47.3 L 10.0 gal 37.9 L 84 lb 38.10 kg
TX-60V-C 3/4 in. Male NPT 16 1/4 in. 412.8 mm 34 in. 864 mm 25.0 gal 94.6 L 11.3 gal 42.8 L 125 lb 56.7 kg
TX-70V-C 3/4 in. Male NPT 16 1/4 in. 412.8 mm 45 3/4 in 864 mm 34.0 gal 94.6 L 11.3 gal 42.8 L 125 lb 56.7 kg
TX-80V-C 1 1/4 in. Female NPT 24 in. 609.6 mm 40 1/2 in. 1029 mm 53.0 gal 200.6 L 34.5 gal 130.6 L 190 lb 86.18 kg
TX-120V-C — Female NPT 24 in. 609.6 mm 47 3/4 in. 1213 mm 66 gal 249.8 L 33 gal 124.9 L 258 lb 117.1 kg
TX-180V-C 1 1/4 in. Female NPT 24 in. 609.6 mm 52 5/8 in. 1338 mm 77.0 gal 291.5 L 33.9 gal 128.3 L 255 lb 115.67 kg
TX-210V-C 1 1/4 in. Female NPT 24 in. 609.6 mm 60 in. 1524 mm 88.0 gal 333.1 L 34.3 gal 129.8 L 295 lb 133.81 kg
TX-42V-C 3/4 in. Female NPT 16 1/4 in. 412.8 mm 24 1/4 in. 616 mm 17.5 gal 66.2 L 11.4 gal 43.2 L 98 lb 44.45 kg
TX-447-C 2 in. Female NPT 24 in. 609.6 mm 60 in. 1524 mm 53.0 gal 200.6 L 34.5 gal 130.6 L 263 lb 119.4 kg
TX-448-C 2 in. Female NPT 24 in. 609.6 mm 46 in. 1168 mm 80.0 gal 302.8 L 52 gal 196.8 L 308 lb 139.8 kg
TX-449-C 2 in. Female NPT 24 in. 609.6 mm 60 in. 1524 mm 106.0 gal 401.2 L 69 gal 261.2 L 353 lb 160.3 kg
TX-450-C 2 in. Female NPT 24 in. 609.6 mm 74 in. 1880 mm 132.0 gal 499.6 L 86 gal 325.5 L 391 lb 177.5 kg
TX-451-C 2 in. Female NPT 30 in. 762 mm 74 1/2 in. 1892 mm 158.0 gal 598 L 103 gal 389.86 L 626 lb 283.95 kg
TX-452-C 2 in. Female NPT 30 in. 762 mm 92 1/2 in. 2349.5 mm 211.0 gal 798.64 L 137 gal 518.55 L 760 lb 344.74 kg
TX-453-C 3 in. Female NPT 36 in. 914.4 mm 85 5/8 in. 2175 mm 264.0 gal 999.24 L 172 gal 651.02 L 810 lb 367.42 kg
TX-454-C 3 in. Female NPT 36 in. 914.4 mm 98 in. 2490 mm 317.0 gal 1199.85 L 206 gal 779.71 L 914 lb 414.59 kg
TX-455-C 3 in. Female NPT 36 in. 914.4 mm 110 3/8 in. 2803.5 mm 370.0 gal 1400.45 L 241 gal 912.19 L 1018 lb 461.76 kg
TX-456-C 3 in. Female NPT 48 in. 1219.2 mm 81 7/8 in. 2080 mm 422.0 gal 1597.27 L 275 gal 1040.88 L 1655 lb 750.71 kg
TX-457-C 3 in. Female NPT 48 in. 1219.2 mm 95 3/4 in. 2432 mm 528.0 gal 1998.48 L 344 gal 1302.04 L 1925 lb 873.18 kg

278 customer.honeywell.com 70-6910


Commercial Expansion Tanks
XPS Series Honeywell Expansion Tanks

Controls
Home
XPS Series (commercial) Expansion Tanks are designed to absorb
hot water expansion in closed heating systems in larger
installations. They are equipped with butyl diaphragms to separate
clamped design. Pre-pressurized at 12 psi, the tank keeps fluids
circulating and maintains minimum system pressure. Honeywell
tanks resist waterlogging, loss of pressure through relief valves
spills, loss BTUs for improved system performance.

Indoor Air Quality


• For ASME construction consult factory.

Maximum Operating Temperature: 240 F (115 C)


Maximum Operating Pressure: 100 psi (689 kPA)
Materials: steel shell, heavy duty butyl diaphragm
Comments: Heating

Combustion Controls
Residential
Con- Maximum
nection Acceptance
Size Diameter Height Volume Volume Weight

Hydronic Controls
Product Connection
Number (inch) Type (inch) (mm) (inch) (mm) (gal) (L) (gal) (L) (lb) (kg)
XPS-030V 1 in. Female NPT 15 3/8 in. 390.5 mm 23 7/8 in. 606 mm 14.0 gal 53.1 L 11.3 gal 42.8 L 25 lb 11.4 kg
XPS-040V 1 in. Female NPT 15 3/8 in. 390.5 mm 31 5/8 in. 803 mm 20.0 gal 75.8 L 11.3 gal 42.8 L 33 lb 15 kg
XPS-060V 1 in. Female NPT 15 3/8 in. 390.5 mm 46 1/2 in. 584 mm 32 gal 121.3 L 11.3 gal 42.8 L 43 lb 19.5 kg
XPS-090V 1 1/4 in. Female NPT 22 in. 558.8 mm 36 in. 914 mm 44 gal 166.8 L 34 gal 128.9 L 69 lb 31.4 kg
XPS-110V 1 1/4 in. Female NPT 22 in. 558.8 mm 46 3/4 in. 876.3 mm 62 gal 235 L 34 gal 128.9 L 92 lb 41.8 kg
XPS-160V 1 1/4 in. Female NPT 26 in. 660.4 mm 47 1/4 in. 1200 mm 86.0 gal 325.9 L 46 gal 174.3 L 123 lb 55.9 kg

Controls
Water
Building Automation
Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 279
280 customer.honeywell.com 70-6910
Thermostatic Mixing Valves
AM-1 Series Thermostatic Mixing Valve

Controls
Home
Indoor Air Quality
®

C US

Combustion Controls
The Honeywell AM-1 series accurately adjusts, maintains and • AM-1 Union STD & C and AM1070 Models include check valves on
limits the hot water temperature to a desired setting selected by both hot and cold ports

Residential
the user. In domestic water applications it offers scalding • ASSE, CSA and IAPMO listed
protection and bacteria growth control. By installing a Honeywell • U.S. Patent No. 6,079,625
AM-1 mixing valve and raising water heater storage temperature
setting and limiting mixed outlet water temperature to safe Application: Domestic water, Nursing homes, Public facilities,
temperature more usable hot water is available. In heating Automatic faucets, Radiant floor heating, Space heating, Combo
applications it provides comfort and protects the equipment. systems, Solar hot water, Greenhouses, Industrial applications, Photo
• Dual purpose mixing or diverting valves processing
• Constant water temperature under changing operating conditions

Hydronic Controls
• Reliable performance at minimum flow of 0.5 gpm Replacement Parts:
• Proportional valve (simultaneous control of hot and cold water) AMCU100 Replacement Check Valve for all AM-1 Series union model
• Temperature limit at any point valves
• Flow reduction in seconds if cold water supply is interrupted AMU200-RP Gasket kit for 1/2 inch, 3/4 inch and 1 inch AM and AM-1
• Nickel-plated brass construction, EPDM O-rings Series valves; 3 gaskets per kit
• High performance thermoplastic proportioning shuttle AM-1-020RP Rebuild kit for AM-1 Series B (60 - 100F; 16-38C) or
• Straight through design (hot and cold at the same level) Series C (80 - 120F; 27 - 49C) range valves. Includes thermal
• Max. pressure 150 psi (1034 kPa) element, spring, diffuser, spool and O-rings
• Max temperature 212 F (100 C) AM-1-025RP Thermal element, spring, and plug assembly. Rebuild kit
• Designed for easy maintenance and element replacement. Teflon® for AM-1 "Standard" series and AMX300 series valves
coating of internal valve components to prevent mineral build-up and

Water Controls
AM-1-030RP Rebuild kit for AM-1 Series 1070 valves; (70 - 120F;
extend life. 21 - 49C). Includes thermal element, spring, diffuser, spool and O-
• Tamper resistant design
rings
• Valve trapping not required

Pipe Size Capacity Operating Temperature Range


Product Number (inch) (DN) Connection Type (Cv) (F) (C) ASSE Comments
AM100-1 1/2 in. DN15 NPT 3.2 Cv 70 F to 145 F 21 C to 63 C 1017 —

Building Automation
AM100-UCPVC-1 1/2 in. DN15 Union CPVC 3.9 Cv 70 F to 145 F 21 C to 63 C 1017 —
AM100-UPEX-1 1/2 in. DN15 Union PEX 3.9 Cv 70 F to 145 F 21 C to 63 C 1017 —
AM100-US-1 1/2 in. DN15 Union Sweat 3.9 Cv 70 F to 145 F 21 C to 63 C 1017 —
AM100-UT-1 1/2 in. DN15 Union NPT 3.9 Cv 70 F to 145 F 21 C to 49 C 1017 —
AM100C-1 1/2 in. DN15 NPT 3.2 Cv 70 F to 120 F 21 C to 49 C 1017 —
AM100C-UCPVC-1 1/2 in. DN15 Union CPVC 3.9 Cv 70 F to 120 F 21 C to 49 C 1017 —
AM100C-UPEX-1 1/2 in. DN15 Union PEX 3.9 Cv 70 F to 120 F 21 C to 49 C 1017 —

Components
Commercial
AM100C-US-1 1/2 in. DN15 Union Sweat 3.9 Cv 70 F to 120 F 21 C to 49 C 1017 —
AM100C-UT-1 1/2 in. DN15 Union NPT 3.9 Cv 70 F to 120 F 21 C to 49 C 1017 —
AM100C1070-UCPVC-1 1/2 in. DN15 Union CPVC 1.8 Cv 70 F to 120 F 21 C to 49 C 1070 —
AM100C1070-UPEX-1 1/2 in. DN15 Union PEX 1.8 Cv 70 F to 120 F 21 C to 49 C 1070 —
AM100C1070-US-1 1/2 in. DN15 Union Sweat 1.8 Cv 70 F to 120 F 21 C to 49 C 1070 —
Pneumatic Controls

AM100C1070-UT-1 1/2 in. DN15 Union NPT 1.8 Cv 70 F to 120 F 21 C to 49 C 1070 —


AM100R-UPEX-1 1/2 in. DN15 Union PEX 3.9 Cv 70 F to 180 F 21 C to 82 C No Approval Heating Only
AM100R-US-1 1/2 in. DN15 Union Sweat 3.9 Cv 70 F to 180 F 21 C to 82 C No Approval Heating Only
AM100R-UT-1 1/2 in. DN15 Union NPT 3.9 Cv 70 F to 180 F 21 C to 82 C No Approval Heating Only
AM101-1 3/4 in. DN20 NPT 3.8 Cv 70 F to 145 F 21 C to 63 C 1017 —
AM101-UCPVC-1 3/4 in. DN20 Union CPVC 3.9 Cv 70 F to 145 F 21 C to 63 C 1017 —
Industrial Combustion

AM101-UPEX-1 3/4 in. DN20 Union PEX 3.9 Cv 70 F to 145 F 21 C to 63 C 1017 —


AM101-US-1 3/4 in. DN20 Union Sweat 3.9 Cv 70 F to 145 F 21 C to 63 C 1017 —
Controls

AM101-UT-1 3/4 in. DN20 Union NPT 3.9 Cv 70 F to 145 F 21 C to 63 C 1017 —

70-6910 281
Thermostatic Mixing Valves
Pipe Size Capacity Operating Temperature Range
Product Number (inch) (DN) Connection Type (Cv) (F) (C) ASSE Comments
AM101C-1 3/4 in. DN20 NPT 3.8 Cv 70 F to 120 F 21 C to 49 C 1017 —
AM101C-UCPVC-1 3/4 in. DN20 Union CPVC 3.9 Cv 70 F to 120 F 21 C to 49 C 1017 —
AM101C-UPEX-1 3/4 in. DN20 Union PEX 3.9 Cv 70 F to 120 F 21 C to 49 C 1017 —
AM101C-US-1 3/4 in. DN20 Union Sweat 3.9 Cv 70 F to 120 F 21 C to 49 C 1017 —
AM101C-UT-1 3/4 in. DN20 Union NPT 3.9 Cv 70 F to 120 F 21 C to 49 C 1017 —
AM101C1070-UCPVC-1 3/4 in. DN20 Union CPVC 1.8 Cv 70 F to 120 F 21 C to 49 C 1070 —
AM101C1070-UPEX-1 3/4 in. DN20 Union PEX 1.8 Cv 70 F to 120 F 21 C to 49 C 1070 —
AM101C1070-US-1 3/4 in. DN20 Union Sweat 1.8 Cv 70 F to 120 F 21 C to 49 C 1070 —
AM101C1070-UT-1 3/4 in. DN20 Union NPT 1.8 Cv 70 F to 120 F 21 C to 49 C 1070 —
AM101R-UPEX-1 3/4 in. DN20 Union PEX 3.9 Cv 70 F to 180 F 21 C to 82 C No Approval Heating Only
AM101R-US-1 3/4 in. DN20 Union Sweat 3.9 Cv 70 F to 180 F 21 C to 82 C No Approval Heating Only
AM101R-UT-1 3/4 in. DN20 Union NPT 3.9 Cv 70 F to 180 F 21 C to 82 C No Approval Heating Only
AM102-1 1 in. DN25 NPT 4.3 Cv 70 F to 145 F 21 C to 63 C 1017 —
AM102-US-1 1 in. DN25 Union Sweat 3.9 Cv 70 F to 145 F 21 C to 63 C 1017 —
AM102-UT-1 1 in. DN25 Union NPT 3.9 Cv 70 F to 145 F 21 C to 63 C 1017 —
AM102C-1 1 in. DN25 NPT 4.3 Cv 70 F to 120 F 21 C to 49 C 1017 —
AM102C-US-1 1 in. DN25 Union Sweat 3.9 Cv 70 F to 120 F 21 C to 49 C 1017 —
AM102C-UT-1 1 in. DN25 Union NPT 3.9 Cv 70 F to 120 F 21 C to 49 C 1017 —
AM102C1070-US-1 1 in. DN25 Union Sweat 1.8 Cv 70 F to 120 F 21 C to 49 C 1070 —
AM102C1070-UT-1 1 in. DN25 Union NPT 1.8 Cv 70 F to 120 F 21 C to 49 C 1070 —
AM102R-US-1 1 in. DN25 Union Sweat 3.9 Cv 70 F to 180 F 21 C to 82 C No Approval Heating Only
AM102R-UT-1 1 in. DN25 Union NPT 3.9 Cv 70 F to 180 F 21 C to 82 C No Approval Heating Only
ON
0
107

AM 3/4 UNI

/4"

/2"

/2"
MC

AL /2"

1 "
AM AM

1-1

1-1

2-1
MX "
1"

2"

3"
LA

1
L
AM

MX

MX

MX

MX

MX
AL

25

20

15

10
9.0
PRESSURE DROP (PSI)

8.0
7.0
6.0
5.0

4.0

3.0
2.5

2.0

1.5

1.0

0.7

0.6
0.5
1.0 1.5 2.0 2.5 3.0 4.0 5.0 6.0 7.0 9.0 15 20 25 30 40 50 60 70 80 90 150 200 250 300
8.0 10 100
FLOW (GPM)
M16710C

282 customer.honeywell.com 70-6910


Thermostatic Mixing Valves
New Style AM-1 Series Valves Replacement Parts

Controls
Home
Product Number Description
AM-1-020RP Rebuild kit for AM-1 Series B (60 - 100F; 16-38C) or Series C (80 - 120F; 27 - 49C) range valves. Includes
thermal element, spring, diffuser, spool and O-rings
AM-1-025RP Thermal element, spring, and plug assembly. Rebuild kit for AM-1 "Standard" series and AMX300 series valves

Indoor Air Quality


AM-1-030RP Rebuild kit for AM-1 Series 1070 valves; (70 - 120F; 21 - 49C). Includes thermal element, spring, diffuser, spool
and O-rings
AMCU100 Replacement Check Valve for all AM-1 Series union model valves

Combustion Controls
Residential
AMU200-RP Gasket kit for 1/2 inch, 3/4 inch and 1 inch AM and AM-1 Series valves; 3 gaskets per kit

Old Style AM Series Valves (manufactured before 2001)


Replacement Parts

Hydronic Controls
Product Number Description
AM100-001RP Rebuild kit for AM C Series valves, 90-120 F (32 - 49C) range. Does not fit AM-1 Series
AM100-002RP Rebuild kit for AM Standard Series valves, 110-145 F (43 - 63C) range. Does not fit AM-1 Series
AM100-010RP Rebuild kit for AM R Series valves, 70 - 100F (21 - 38C) range. Does not fit AM-1 Series
AMU200-RP Gasket kit for 1/2 inch, 3/4 inch and 1 inch AM and AM-1 Series valves; 3 gaskets per kit

Mixing Valve Accessories

Water Controls
Product Number Description
AM08-038 1/2 inch Sweat union kit. Includes tailpiece, union nut and gasket
AM08-039 3/4 inch Sweat union kit. Includes tailpiece, union nut and gasket
AM08-040 1 inch Sweat union kit. Includes tailpiece, union nut, gasket and retaining ring

Building Automation
AM08-041 1/2 inch NPT union kit. Includes tailpiece, union nut and gasket
AM08-042 3/4 inch NPT union kit. Includes tailpiece, union nut and gasket
AM08-043 1 inch NPT union kit. Includes tailpiece, union nut, gasket and retaining ring
AM206-040 3/4 inch CPVC union kit. Includes tailpiece, union nut and gasket
AM206-041 1/2 inch PEX union kit. Includes tailpiece, union nut and gasket
AM206-042 3/4 inch PEX union kit. Includes tailpiece, union nut and gasket
CVT-050 3/4 in. FNPT x 3/4 in. MNPT Check Adapter for use with AM-1 NPT valves

Components
Commercial
CVT-075 1/2 in. FNPT x 1/2 in, MNPT Check Adapter for use with AM-1 NPT valves

MX050-RP 1/2 inch Recirculation adapter kit. Includes 1/2 inch MNPT union nut and gasket
Pneumatic Controls

TS205-064 Thermostrip temperature indicator for potable mixing valves, 110-140F (43 - 60C)
range Strip

TS206-080 Thermostrip temperature indicator for R Series radiant mixing valves, 105 - 180F (41 -
105 41
110 43
115 46
120 49
125 51
130 54
135 57
140 60
145 63
150 66
155 68
160 71
165 74
170 77
175 79
180 82

82C) range
°F
M25433

Thermostrip
°C

Accuracy expires
after MMYYY

Replacement Parts SM Series (Old Style)


Industrial Combustion
Controls

Product Number Description


SM100-004RP SM Series Element, spring and shuttle assembly

70-6910 283
Thermostatic Mixing Valves
AMX Series DirectConnect™ Thermostatic Mixing Valves
Patented DirectConnect™ design reduces installation time.
Orientation of cold and hot ports eliminates need for elbows and
tees on typical water heater installations. Added safety designed to
prevent scalding. Increased user comfort for more available hot
water. Designed to be directly installed on water heater hot outlet
port.
• Designed to be directly installed on water heater hot outlet port.
• Constant water temperature under different operating conditions
• Proportional valve (control of hot and cold water)
• Flow reduction in seconds if cold water supply is interrupted
® • Temperature adjustable using 3/16 allen wrench (supplied)
• Union nuts/tail pieces included
• Heat trapping not required
® • Recirculation port option for fast response
• Integral check valve on cold port
C US • Brass/stainless construction
• Teflon coated wear surfaces for extended service
• ASSE 1017 certified, CSA & IAPMO listed
• U.S. Patent pending

Application: Heat Pump Systems, Domestic water, Nursing homes,


Public facilities, Automatic faucets, Radiant floor heating, Space
heating, Combo systems, Solar hot water, Greenhouses, Industrial
applications, Photo processing
Operating Temperature Range: 90 F to 130 F (32 C to 54 C)
Capacity: 4 Cv
ASSE: 1017
Replacement Parts:
AMX-001RP AMX element, spring, plug assembly. For AMX100 -
AMX102 series valves only

Pipe Size
Product Number (inch) DN Connection Type Comments
AMX100-UCPVC-1 1/2 in. DN15 Union CPVC, 3/4 in. Bottom AMX100 and AMX101 Series valves include 3/4 in. NPT bottom connection
AMX100-UPEX-1 1/2 in. DN15 Union PEX, 3/4 in. Bottom AMX100 and AMX101 Series valves include 3/4 in. NPT bottom connection
AMX100-US-1 1/2 in. DN15 Union Sweat, 3/4 in. Bottom AMX100 and AMX101 Series valves include 3/4 in. NPT bottom connection
AMX100-UT-1 1/2 in. DN15 Union NPT, 3/4 in. Bottom AMX100 and AMX101 Series valves include 3/4 in. NPT bottom connection
AMX101-UCPVC-1 3/4 in. DN20 Union CPVC, 3/4 in. Bottom AMX100 and AMX101 Series valves include 3/4 in. NPT bottom connection
AMX101-UPEX-1 3/4 in. DN20 Union PEX, 3/4 in. Bottom AMX100 and AMX101 Series valves include 3/4 in. NPT bottom connection
AMX101-US-1 3/4 in. DN20 Union Sweat, 3/4 in. Bottom AMX100 and AMX101 Series valves include 3/4 in. NPT bottom connection
AMX101-USMT-1 3/4 in. DN20 — AMX100 and AMX101 Series valves include 3/4 in. NPT bottom connection
AMX101-UT-1 3/4 in. DN20 Union NPT, 3/4 in. Bottom AMX100 and AMX101 Series valves include 3/4 in. NPT bottom connection
AMX102-US-1 1 in. DN25 Union Sweat, 1 in. Bottom AMX102 Series valves include 1 in. NPT bottom connection
AMX102-UT-1 1 in. DN25 Union NPT, 1 in. Bottom AMX102 Series valves include 1 in. NPT bottom connection
Dimensions in inches (millimeters)

D C

PRODUCT DIMENSIONS (INCHES)


NUMBER A B C D
M
ADJUSTMENT AMX100-UCPVC-1 3-1/2 8-7/16 2-11/16 1-1/2

AMX100-UPEX-1 3-1/2 8-5/8 2-15/16 1-1/2

AMX100-US-1 3-1/2 8-3/16 2-1/2 1-1/2


RECIRCULATION R
AMX100-UT-1 3-1/2 8-1/2 2-13/16 1-1/2
B AMX101-UCPVC-1 4-3/16 9 2-1/2 1-1/2
AMX Serie
s
AMX101-UPEX-1 4-3/16 9-3/16 2-11/16 1-1/2
ASSE 1017 C
AMX101-US-1 4-3/16 9 2-1/2 1-1/2
H AMX101-UT-1 4-3/16 9-11/16 3-1/2 1-1/2

A AMX102-US-1 4-1/2 10 3-1/2 1-1/2

AMX102-UT-1 4-1/2 10.3 3-13/16 1-1/2


M27478A

284 customer.honeywell.com 70-6910


Thermostatic Mixing Valves
AMX Series DirectConnect Replacement Part

Controls
Home
Product Number Description
AMX-001RP AMX element, spring, plug assembly. For AMX100 - AMX102 series valves only
Thermostatic Mixing Valve Installation

Indoor Air Quality


Combustion Controls
Residential
AM-1 SERIES CONNECTION AMX SERIES AMX 300 SERIES

Hydronic Controls
DIRECTCONNECT CONNECTION DIRECTCONNECT CONNECTION
M31168

Water Controls
Building Automation
Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 285
Thermostatic Mixing Valves
AMX300 Series DirectConnect™ Thermostatic Mixing Valve and Kits
• Kit includes ASSE 1017 mixing valve, cold water tee fitting and
flexible stainless steel connector
• For performance specifications of the kits, please refer to data
provided for the AMX300 valve
• Mixing valve and cold water tee both connect directly to water
heater; flexible stainless steel connector joins the cold water tee
directly to the cold inlet port of the mixing valve
• Fits virtually all water heaters up to 1 in. (all necessary adapters
included)
• Increased user comfort for more available hot water.
• Constant water temperature under different operating conditions
• Proportional valve (control of hot and cold water)
• Flow reduction in seconds if cold water supply is interrupted
• Temperature adjustable with easy "Push-Twist-Release" locking
hand wheel design
• Union nuts/tail pieces/adapters (for certain models) included
• Recirculation port option for fast delivery of heated water to furthest
AMX300T and AMX302T Kits fixtures
• Alternate hot port for bypass of hot water directly from tank to
nonmixed temperature applications (dishwashers, clothes washers,
New AMX300 kits reduce installation time to an minimum while still etc.)
providing Honeywell's industry leading mixing valve technology • Integral check valve on cold port
• Excellent temperature stability and control • Brass/stainless construction
• Effectively minimizes scalding risk to building occupants • Teflon coated wear surfaces for extended service
• ASSE 1017 certified, IAPMO listed (cUPCus)
Application: Domestic Hot Water Minimum Flow Rate: 0.25 gpm; Recirculation Port: 1/2 in. NPT;
Valve Capacity: 2.1 Cv Alternate Hot Port: 1/2 in. NPT
Mixed Water Supply Temperature Range: (0.95 lpm; Recirculation Port: 1/2 in. NPT; Alternate Hot Port:
100 F to 145 F (38 C to 63 C) 1/2 in. NPT)
Operating Temperature Range: Maximum Working Pressure: 150 psi
100 F to 212 F (hot water inlet) 33 F to 80 F (cold water inlet) ASSE: 1017 (AMX300 valve)
((38 C to 100 C) (hot water inlet) (0.5 C to 27 C (cold water inlet))
Replacement Parts:
AM-1-025RP Thermal element, spring, and plug assembly. Rebuild kit
for AM-1 "Standard" series and AMX300 series valves

Pipe Size
Product Number (inch) (DN) Connection Type Description
AMX300 3/4 in. DN20 Cold Inlet - 7/8 in.-14 SAE J513, 3/4 in. ASSE 1017 mixing valve (Replacement valve tor AMX300T
45 degree flare fitting; and AMX302T DirectConnect mixing valve kits.)
Mixed Outlet - Male NPT;
Hot Inlet - Female NPT
AMX300T 1/2 in. DN15 Mixed Outlet - Male NPT; DirectConnect water heater kit with 3/4 in. ASSE 1017 mixing valve,
Hot Inlet - Female NPT 3/4 in. cold water tee, and 8-in. SS flex connector
AMX302T 1 in. DN25 Mixed Outlet - Male NPT; DirectConnect water heater kit with 3/4-in. ASSE 1017 mixing valve,
Hot Inlet - Female NPT 3/4-in. cold water tee, and 11-in. SS flex connector

AMX Series DirectConnect Replacement Part


Product Number Description
AM-1-025RP Thermal element, spring, and plug assembly. Rebuild kit for AM-1 "Standard" series and AMX300 series valves

286 customer.honeywell.com 70-6910


Thermostatic Mixing Valves
UMV Series Undersink Mixing Valves

Controls
Home
Universal 3 or 4 Port connection for 3/8 in. compression undersink
applications. Includes internal check valves in hot and cold ports
to prevent cross flow. Easy installation kit includes 3/8
compression nuts, ferrules and stand-offs for secure mounting.
Forged brass body construction. Tamper resistant temperature
control handwheel locks into desired temperature position.
• Universal adapter for 3 Port connection

Indoor Air Quality


• 3/8 compression connections for easy installation
• Includes internal check valves in hot and cold ports to prevent cross
® flow.
• Tamper resistant hand wheel locks into desired temperature position
• Temperature adjustment range 80-120F
• Controls temperature with flow as low as 0.5 gpm
® • Forged brass body with pilot holes for secure mounting
C US • ASSE 1016 and ASSE 1070 listed

Combustion Controls
Typical Installation

Residential
Hydronic Controls
MIX COLD
MIX

C
M M

COLD

C
H H

C
HOT
HOT COLD

Water Controls
THREE PORT APPLICATION FOUR PORT APPLICATION
M25022

Application: UMV Series 3/8 in. Compression


Connection Type: Compression
ASSE: 1016, 1070

Pipe Size Capacity Operating Temperature Range

Building Automation
Product Number (inch) DN (Cv) (F) (C) Description
UMV-304U 3/8 in. DN20 0.55 Cv 70 F to 120 F 21 C to 49 C 3/8 in. compression Universal 3 or 4 Port Connection

Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 287
Pressure Regulating Valves
D05T Pressure Regulating Valve–Compact Design
• Flow capacity and accuracy make D05T suitable for a variety of
applications
• Bronze body construction with stainless steel and engineered
thermoplastic internal parts
• One piece non-corroding unitized cartridge
• Fully balanced regulator mechanism with fabric reinforced
diaphragm
• Includes balanced seat for accurate pressure output under varying
inlet pressures up to 400psi
• Inlet and outlet internally and externally threaded (NPT) for union
connection
• Built-in strainer and thermal by-pass
• ASSE 1003 and IAPMO listed
Compact Design pressure regulating valves for new residential
and light commercial construction, drip irrigation and other
applications requiring sensitive and accurate regulation.
Calibrated Adjustment Dial: No Materials: Bronze (body), Fabric reinforced diaphragm, Stainless steel
Gauge Tap: 1/4 in. NPT and engineered thermoplastics.
Reducing Ratio: 10:1 maximum Approvals:
Maximum Inlet Pressure Rating (psi): 400 psi Canadian Standards Association: Certified (B356)
Pipe Connection: Female NPT threaded inlet and outlet. Externally ASSE: Certified (1003)
threaded for unions. IAPMO: Listed
Outlet Pressure Adjustment Range (psi): 15-90 psi
Temperature Range: 180 F (82 C)

Pipe Size Dimensions, Approximate


Product Number (inch) (DN) (inch) (mm) Union Fittings
D05T1011 3/4 in. DN20 6 5/8 in. high x 3 1/2 in. wide 168 mm high x 89 mm long Union body, no tailpieces
D05T1029 3/4 in. DN20 6 5/8 in. high x 5 3/16 in. long 168 mm high x 132 mm long Double-union sweat
D05T1045 1 in. DN25 4 1/2 in high x 4 in. long 114 mm high x 142 mm wide Union body, no tailpieces
D05T1052 1 in. DN25 8 5/8 in. high x 6 1/2 in. long 218 mm high x 166 mm long Double-union sweat
D05T1060 3/4 in. DN20 6 5/8 in. high x 5 3/16 in. long 168 mm high x 132 mm long Double-union threaded
D05T1078 1 in. DN25 6 5/8 in. high x 5 3/16 in. long 168 mm high x 132 mm long Double-union threaded
D05T1086 3/4 in. DN20 6 5/8 in. high x 5 3/16 in. long 168 mm high x 132 mm long Single-union sweat
D05T1094 3/4 in. DN20 6 5/8 in. high x 4 5/16 in. wide 168 mm high x 110 mm long Single-union threaded
D05T1102 1 in. DN25 8 5/8 in. high x 5 in. long 218 mm high x 127 mm long Single-union sweat
D05T1110 1 in. DN25 8 5/8 in. high x 5 in. long 218 mm high x 127 mm long Single-union threaded

288 customer.honeywell.com 70-6910


Pressure Regulating Valves
DS05 "DialSet" Pressure Regulating Valves

Controls
Home
• Dial is calibrated in 10 psi increments to allow quick and accurate
adjustment of outlet pressure.
• Flow capacity and accuracy make the DS05 suitable for potable
water service and most irrigation applications.
• High pressure (400 psi) inlet rating.
• Non-corroding unitized cartridge contains all working parts and is
easily replaceable.

Indoor Air Quality


• Bronze body with stainless steel and engineered thermoplastic
internal parts.
• Balanced single seat for accurate pressure output under varying
inlet pressures.
• Inlet and outlet are internally threaded female NPT, and externally
threaded for use with union assemblies.
Valves for new residential and light commercial construction, drip • Built-in strainer and thermal bypass.
irrigation, and other applications requiring highly sensitive and • One model can be used in low, standard or high pressure
accurate regulation. Easy DialSet® Adjustment (no gauge applications.

Combustion Controls
required).

Residential
Calibrated Adjustment Dial: Yes Materials: Bronze (body), Fabric reinforced diaphragm, Stainless steel
Gauge Tap: none and engineered thermoplastics.
Reducing Ratio: 10:1 maximum Approvals:
Pipe Connection: Female NPT threaded inlet and outlet. Externally Canadian Standards Association: Certified (B356)
threaded for unions. ASSE: Certified (1003)
Maximum Inlet Pressure Rating (psi): 400 psi IAPMO: Listed
Temperature Range: 180 F (82 C)

Hydronic Controls
Pipe Size Dimensions, Approximate Outlet
Pressure
Adjustment
Product Number (inch) (DN) (inch) (mm) Range (psi) Union Fittings
DS05C1006 1/2 in. DN15 5 1/4 in. high x 3 3/8 in. long 133 mm high x 86 mm long 15-90 psi Union body, no tailpieces
DS05C1014 1/2 in. DN15 5 1/4 in. high x 3 7/8 in. long 133 mm high x 98 mm wide 15-90 psi Single-union sweat
DS05C1022 1/2 in. DN15 5 1/4 in. high x 4 1/16 in. long 133 mm high x 103 mm wide 15-90 psi Single-union threaded
DS05C1030 3/4 in. DN20 5 1/4 in. high x 3 3/8 in. long 133 mm high x 86 mm long 15-90 psi Union body, no tailpieces

Water Controls
DS05C1048 3/4 in. DN20 5 1/4 in. high x 4 5/16 in. long 133 mm high x 110 mm wide 15-90 psi Single-union sweat
DS05C1055 3/4 in. DN20 5 1/4 in. high x 4 5/16 in. long 133 mm high x 110 mm wide 15-90 psi Single-union threaded
DS05C1063 1 in. DN25 5 1/4 in. high x 3 15/16 in. long 133 mm high x 100 mm wide 15-90 psi Union body, no tailpieces
DS05C1071 1 in. DN25 5 1/4 in. high x 5 1/4 in. long 133 mm high x 133 mm long 15-90 psi Single-union sweat
DS05C1089 1 in. DN25 5 1/4 in. high x 5 in. long 133 mm high x 127 mm long 15-90 psi Single-union threaded

Building Automation
DS05D1005 1/2 in. DN15 5 1/4 in. high x 5 9/16 in. long 133 mm high x 141 mm long 15-90 psi Double-union sweat
DS05D1013 1/2 in. DN15 5 1/4 in. high x 5 15/16 in. long 133 mm high x 125 mm long 15-90 psi Double-union threaded
DS05D1021 3/4 in. DN20 5 1/4 in. high x 6 1/16 in. long 133mm high x 154 mm long 15-90 psi Double-union sweat
DS05D1039 3/4 in. DN20 5 1/4 in. high x 5 3/16 in. long 133 mm high x 132 mm long 15-90 psi Double-union threaded
DS05D1047 1 in. DN25 5 1/4 in. high x 6 1/2 in. long 133 mm high x 166 mm long 15-90 psi Double-union sweat
DS05D1054 1 in. DN25 5 1/3 in. high x 5 3/16 in. long 133 mm high x 132 mm long 15-90 psi Double-union threaded
DS05D1062 1 1/4 in. DN32 8 5/8 in. high x 7 11/16 in. long 218 mm high x 195 mm long 15-150 psi Double-union sweat
DS05D1070 1 1/4 in. DN32 8 5/8 in. high x 7 5/16 in. long 218 mm high x 186 mm long 15-150 psi Double-union threaded

Components
Commercial
DS05G1085 1 1/4 in. DN32 8 5/8 in. high x 6 in. long 218 mm high x 152 mm long 15-150 psi Single-union threaded
DS05G1093 1 1/4 in. DN32 8 5/8 in. high x 6 3/16 in. long 218 mm high x 157 mm long 15-150 psi Single-union sweat
DS05G1127 1 1/4 in. DN32 8 5/8 in. high x 4 11/16 in. long 218 mm high x 119 mm long 15-150 psi Union body, no tailpieces
Pneumatic Controls
Industrial Combustion
Controls

70-6910 289
Pressure Regulating Valves
DS06 "DialSet" Pressure Regulating Valves
High quality pressure regulating valve that maintains a constant
outlet pressure over a wide range of inlet supply pressures.
Includes calibrated outlet pressure set dial that allows outlet
pressure adjustments without the use of a gauge in most
applications. Easy DialSet® Adjustment (no gauge required)
• Ideally suited for potable water and irrigation applications requiring
accurate regulation.
• Wide outlet pressure range, high inlet pressure, and compact design
allow flexibility in installation and application.
• Non-corroding unitized cartridge contains all working parts and is
easily replaceable.
• Includes built-in strainer and thermal bypass.
• Balanced seat construction provides superior pressure regulation.
• Gauge tapped.

Calibrated Adjustment Dial: Yes Materials: Bronze (body), Fabric reinforced diaphragm, Stainless steel
Gauge Tap: 1/4 in. NPT (two, one on each side of body). and engineered thermoplastics.
Reducing Ratio: 10:1 maximum Approvals:
Pipe Connection: Female NPT threaded inlet and outlet. Externally Canadian Standards Association: Certified (B356)
threaded for unions. ASSE: Certified (1003)
Maximum Inlet Pressure Rating (psi): 400 psi IAPMO: Listed
Outlet Pressure Adjustment Range (psi): 15-130 psi
Temperature Range: 180 F (82 C)

Pipe Size Dimensions, Approximate


Product Number (inch) (DN) (inch) (mm) Union Fittings
DS06D1003 1 1/2 in. DN40 11 13/16 in. high x 9 3/8 in. long 299 mm high x 238 mm long Double-union sweat
DS06D1011 1 1/2 in. DN40 11 13/16 in. high x 9 3/16 in. long 299 mm high x 233 mm long Double-union threaded
DS06D1029 2 in. DN50 11 13/16 in. high x 10 3/16 in. long 299 mm high x 257 mm long Double-union sweat
DS06D1037 2 in. DN50 11 13/16 in. high x 9 5/16 in. long 299 mm high x 237 mm long Double-union threaded
DS06G1000 1 1/2 in. DN40 11 13/16 in. high x 7 13/16 in. long 299 mm high x 198 mm long Single-union threaded
DS06G1018 1 1/2 in. DN40 11 13/16 in. high x 7 7/8 in. long 299 mm high x 201 mm long Single-union sweat
DS06G1026 2 in. DN50 11 13/16 in. high x 7 7/8 in. long 299 mm high x 200 mm long Single-union threaded
DS06G1034 2 in. DN50 11 13/16 in. high x 8 5/16 in. long 299 mm high x 211 mm long Single-union sweat
DS06G1042 1 1/2 in. DN40 11 13/16 in. high x 6 3/8 in. long 299 mm high x 162 mm long Union body, no tailpieces
DS06G1059 2 in. DN50 11 13/16 in. high x 6 3/8 in. long 299 mm high x 162 mm long Union body, no tailpieces

290 customer.honeywell.com 70-6910


Pressure Regulating Valves Parts and Accessories
D05/DS05 Pressure Regulating Valves—Accessories

Controls
Home
Product Number Description Used With
272840 Union gaskets for 1/2 in. D05/DS05 (package of 2) D05; DS05
272841 Union gaskets for 3/4 in. D05/DS05 (package of 2) D05; DS05
272842 Union gasket for 1 in. D05/DS05 (package of 2) D05; DS05

Indoor Air Quality


K06U1069 Union kit for D05 for 1/2-in. NPT valves. Includes union nut, threaded tail piece, and gasket D05
K06U1077 Union kit for D05 for 3/4-in. NPT valves. Includes union nut, threaded tail piece, and gasket D05
K06U1085 Union kit for D05 for 1-in. NPT valves. Includes union nut, threaded tail piece, and gasket D05
K06U1093 Union kit for D05 for 1/2-in. sweat valves. Includes union nut, sweat tail piece, and gasket D05
K06U1101 Union kit for D05 for 3/4-in. sweat valves. Includes union nut, sweat tail piece, and gasket D05
K06U1119 Union kit for D05 for 1-in. sweat valves. Includes union nut, sweat tail piece, and gasket D05

Combustion Controls
K06U1135 Union kit for D05 for 1-1/4-in. NPT valves. Includes union nut, threaded tail piece, and gasket D05

Residential
K06U1143 Union kit for D05 for 1-1/4-in. sweat valves. Includes union nut, sweat tail piece, and gasket D05

D05/DS05 Pressure Regulating Valves—Repair Parts


Product Number Description Used With
203223 Bonnet kit for 1/2 in. and 3/4 in. D05 valves. Consists of bonnet and threaded insert D05

Hydronic Controls
272838 Bonnet kit for 1/2 in. and 3/4 in. DS05 valves DS05
272839 Bonnet kit for 1 in. and 1 1/4 in. DS05 valves DS05
K05A1009 Repair Kit for old style D05A,G; DS05G series 1/2 in. and 3/4 in. valves. Includes cartridge, screen and O-rings D05; DS05
K05A1017 Repair Kit for old style D05A,G; DS05G 1 in. and 1-1/4 in. valves. Includes cartridge, screen and O-rings D05; DS05
K05A1025 Repair kit for new D05T, DC05C,D,G 1/2 in., 3/4 in., and 1-in. valves. Includes cartridge, screen and O-ring D05T; DS05
K05B1007 Repair Kit for new D05T; DS05C,D,G 1/2-in. and 3/4-in. valves. Includes screen and O-rings D05T; DS05
K05B1015 Repair Kit for new D05T and DS05C,D,G 1-in. valves. Includes screen and O-rings D05T; DS05

Water Controls
K06A1003 Cartridge kit for D05G and DS05G 1/2 and 3/4 in. valves. Includes cartridge, screen and O-rings D05; DS05
K06A1011 Cartridge kit for D05G and DS05G 1 and 1-1/4 in. valves. Includes cartridge, screen and O-rings D05; DS05
K06A1019 Cartridge kit for D05G and DS05G 1/2 and 3/4 in. valves. Includes screen, plug and O-rings D05; DS05
K06B1002 Cartridge kit for D05G and DS05G 1 and 1-1/4 in. valves. Includes screen, plug and O-rings D05; DS05
K06B1018 Cartridge kit for D05G and DS05G 1 and 1-1/4 in. valves. Includes screen, plug and O-rings D05; DS05

Building Automation
K06C1036 Spring kit for D05G and DS05G 1 and 1-1/4 in. valves. 21-85 psi. Includes spring and adjustment knob (grey) D05; DS05
K06C1044 Spring kit for D05G and DS05G 1 and 1-1/4 in. valves. 85-170 psi. Includes spring and adjustment knob (red) D05; DS05
K06D1001 Cartridge kit for D05G and DS05G 1/2 and 3/4 in. valves. Includes cartridge and O-rings D05; DS05
K06D1009 Cartridge kit for D05G and DS05G 1 and 1-1/4 in. valves. Includes cartridge and O-rings D05; DS05

D06/DS06 Pressure Regulating Valves—Accessories


Product Number Description Used With

Components
Commercial
272858 Union Gasket for 1 1/2 in. D06 and DS06G valves D06; DS06G
272859 Union gaskets for 2-in. D06 and DS06 valves D06; DS06
K06U1037 Union kit for D06 for 1-1/2-in. NPT valves. Includes union nut, sweat tail piece, and gasket D06
K06U1045 Union kit for D06 for 2-in. NPT valves. Includes union nut, sweat tail piece, and gasket D06
K06U5034 Union kit for D06 for 1-1/2-in. sweat valves. Includes union nut, sweat tail piece, and gasket D06
K06U5042 Union kit for D06 for 2-in. sweat valves. Includes union nut, sweat tail piece, and gasket D06
Pneumatic Controls

D06/DS06 Pressure Regulating Valves—Repair Parts


Product Number Description Used With
272867 Bonnet kit for 1-1/2 in. and 2 in. DS06 valves DS06
K06B1030 Cartridge kit for D06G and DS06G 1-1/2-in. and 2-in. valves. Includes strainer, support and 2 O-rings D06; DS06
Industrial Combustion

K06C1060 Spring kit for D06G and DS06G 1-1/2 and 2 in. valves. 21-85 psi. Includes spring and adjustment knob (grey) D06; DS06
K06D1017 Cartridge kit for D06G and DS06G 1-1/2 and 2 in. valves. Includes cartridge and O-rings D06; DS06
Controls

K06D1044 Cartridge kit for D06G,T,U and DS06G 1-1/2-in. and 2in. valves. Includes cartridge, screen and O-rings. D06; DS06

70-6910 291
Water Filters
F74C Reversing Rinsing Filter
F74C Reverse Rinsing Filters ensure a continuous supply of
filtered water. The fine filter prevents the ingress of foreign bodies,
such as rust particle and grains of sand. Both horizontal and
vertical installations are possible.
• Whole House Protection
• Filtered water supplied even during reverse rinsing. Patented
reverse rinsing system.
• Fast and thorough cleaning of the filter with a small amount of water.
• Bayonet connection enables simple retro-fitting of reverse rinsing
actuator.
• Large filter surface.
• Shock resistant, clear synthetic material filter bowl enables easy
inspection of filter contamination.
• Filter insert fully interchangeable.
• Simple operation.
• Tested for reliability.

Dimensions in inches (millimeters)


Materials (Body): Plastic with Brass Fittings
Sump: Clear Plastic
Connection Type: Sweat and threaded
Temperature Rating: 86 F Maximum (30 C Maximum)
Weight: 6 lb (2.7 kg)
L

h
H

IN INCHES (MM)
DIMENSION
F74C1015 F74C1023
H 12-13/16 (324) 12-13/16 (324)
h 11-3/16 (285) 11-3/16 (285)
L 6-3/8 (162) 7-1/4 (184)
I 3-9/16 (90) 3-15/16 (100)
D 4-1/8 (105) 4-1/8 (105)
T 5-5/16 (150) 5-5/16 (150)
M18087B

Pipe Size Capacity Pressure Ratings


Product Number (inch) DN (Cv) Screen Size (psi) Includes
F74C1015 3/4 in. DN20 6.4 Cv 100 micron screen 230 psi maximum gauge and wrench
F74C1023 1 in. DN25 7.0 Cv 100 micron screen 230 psi maximum gauge and wrench

292 customer.honeywell.com 70-6910


Water Filters
F76 Water Filters

Controls
Home
High flow capacity water filter used to remove sediment and debris
from residential or commercial water systems.
• Whole House Protection
• Ideally suited for sediment removal applications that would quickly
plug and restrict the flow of normal filters.
• Used as a prefilter, the F76 protects elements of the water system,
including specialized treatment devices or other common fixtures

Indoor Air Quality


and appliances.
• The flow filtering capacity and ease of cleaning make the F76S ideal
for the most demanding applications.
• Built-in secondary filter provides an uninterrupted supply of filtered
water during backwashing.

Combustion Controls
Residential
Dimensions in inches (millimeters)

Hydronic Controls
100
50 150

0 200
Honeywell
Braukmann

DIMENSIONS IN INCHES (MM)

Water Controls
PRODUCT NUMBER 1
H AND SIZE L l D H h WEIGHT

F76S1007 1/2 IN. 6-11/16 (170) 4-5/16 (110) 3-13/16 (97) 17-11/16 (449) 13-13/16 (350) 6.4 (2.9)

h F76S1015 3/4 IN. 7 (178) 4-5/16 (110) 3-13/16 (97) 17-11/16 (449) 13-13/16 (350) 6.4 (2.9)

F76S1023 1 IN. 8-1/4 (209) 5-1/8 (130) 3-13/16 (97) 17-7/8 (453) 13-13/16 (350) 6.8 (3.1)

F76S1031 1-1/4 IN. 8-3/4 (222) 5-1/8 (130) 3-13/16 (97) 17-7/8 (453) 13-13/16 (350) 7.3 (3.3)

Building Automation
F76S1049 1-1/2 IN. 9-11/16 (246) 5-15/16 (150) 4-3/4 (119) 20-15/16 (532) 16-7/16 (417) 8.8 (4.0)

D F76F1056 2 IN. 10-1/2 (267) 5-15/16 (150) 4-3/4 (119) 20-15/16 (532) 16-7/16 (417) 10.6 (4.8)
l
L 1 WEIGHT IN POUNDS (KILOGRAMS) M18084A

Materials (Body): Brass Temperature Rating: 104 F Maximum (40 C Maximum)


Sump: Clear Plastic Weight: 6.4 lb (2.9 kg)
Connection Type: NPT External Threaded and Sweat

Components
Commercial
Pipe Size Capacity Pressure Ratings
Product Number (inch) DN (Cv) Screen Size (psi) Includes
F76S1007 1/2 in. DN15 5.6 Cv 100 micron screen 230 psi maximum gauge and service wrench
F76S1015 3/4 in. DN20 8.4 Cv 100 micron screen 230 psi maximum gauge and service wrench
F76S1023 1 in. DN25 11.4 Cv 100 micron screen 230 psi maximum gauge and service wrench
Pneumatic Controls

F76S1031 1 1/4 in. DN32 12.4 Cv 100 micron screen 230 psi maximum gauge and service wrench
F76S1049 1 1/2 in. DN40 24.4 Cv 100 micron screen 230 psi maximum gauge and service wrench
F76S1056 2 in. DN50 25.5 Cv 100 micron screen 230 psi maximum gauge and service wrench
Industrial Combustion
Controls

70-6910 293
Water Filters
FF06 Rinseable Fine Filter
The FF06 Rinseable Fine Filter ensures a continuous supply of
filtered water. The fine filter stops the flow of particulates, such as
rust particles and grains of sand. Sediment collected at the bottom
of the bowl can simply be removed by flushing with the turn of a
knob. This compact filter was designed to fit where the space is
limited.
• Easy installation.
• Same installed dimensions as F74C for easy future upgrade to a
backwashable filter.
• Continuous supply of filtered water, even during rinse cycle.
• Shock resistant clear synthetic material filter bowl enables easy
inspection for filter contamination.
• Stainless steel filter element.
• Filter bowl and sleeve are easily exchanged.
• Shipped with threaded and sweat union connections and service
wrench.

Dimensions in inches (millimeters) FF06 Exploded View

L A
l A

B C

IN INCHES (MM)
DIMENSION
FF06A1013 FF06A1021

L 6-1/4 (158) 7-1/16 (179)


I 3-9/16 (90) 3-15/16 (100)
h 7-1/16 (180) 7-1/16 (180)
PART
M18086C DESCRIPTION
NUMBER

0901444 GASKET 3/4 IN. (10 PCS)


A
0901445 GASKET 1 IN. (10 PCS)
B and D AS 06-1A FILTER MESH AND SUMP O-RING (5 PCS)

C KF 06-1A CLEAR FILTER BOWL, COMPLETE


WITH FILTER MESH AND CARRIER
M17536B

Materials (Body): Dezincification-resistant (DZR) forged Brass Temperature Rating: 104 F Maximum (40 C Maximum)
Sump: Clear Plastic Weight: 2.2 lb (1.0 kg)
Connection Type: NPT External threaded and sweat

Pipe Size Capacity Pressure Ratings


Product Number (inch) DN (Cv) Screen Size (psi) Includes
FF06A1013 3/4 in. DN20 7.3 Cv 100 micron screen 230 psi maximum service wrench
FF06A1021 1 in. DN25 8.4 Cv 100 micron screen 230 psi maximum service wrench

294 customer.honeywell.com 70-6910


Water Filter Parts and Accessories
Water Sediment Filter Parts and Accessories

Controls
Home
Product Number Description Used With
0901444 Union gasket for 1/2 in. or 3/4 in. connections F76S, FF06, F74C
0901445 Union gasket for 1 in. connections F76S, FF06, F74C
0901446 Union gasket for 1-1/4 in. connections F76S

Indoor Air Quality


0901447 Union gasket for 1-1/2 in. connections F76S
0901448 Union gasket for 2 in. connections F76S
AF11S-112A 100 Micron Screen kit for F76S Water Filter 1-1/2 in. to 2 in. F76S
AF11S-112B 20 Micron Screen kit for F76S Water Filter 1-1/2 in. to 2 in. F76S
AF11S-112C 50 Micron Screen kit for F76S Water Filter 1-1/2 in. to 2 in. F76S
AF11S-112D 200 Micron Screen kit for F76S Water Filter 1-1/2 in. to 2 in. F76S

Combustion Controls
AF11S-1A 100 Micron Screen kit for F76S Water Filter 1/2 in. to 1-1/4 in. F76S

Residential
AF11S-1B 20 Micron Screen kit for F76S Water Filter 1/2 in. to 1-1/4 in. F76S
AF11S-1C 50 Micron Screen kit for F76S Water Filter 1/2 in. to 1-1/4 in. F76S
AF11S-1D 200 Micron Screen kit for F76S Water Filter 1/2 in. to 1-1/4 in. F76S
AF74-1A Insert Filter 100 Micron Screen F74C
AS06-1A Filter mesh and sump O-ring (5 pcs) —

Hydronic Controls
FT09RS-112A Bronze Sump for F76S Water Filter 1-1/2 in. to 2 in. F76S
FT09RS-1A Bronze Sump for F76S Water Filter 1/2 in. to 1-1/4 in. F76S
KF11S-112A Clear Plastic Sump for F76S Water Filter 1-1/2 in. to 2 in. F76S
KF11S-1A Clear Plastic Sump for F76S Water Filter 1/2 in. to 1-1/4 in. F76S

MV876 Automatic Backwash Control


The MV876B Automatic-Backwash Control is available as an

Water Controls
accessory. This control is fitted to the drain valve and is
programmed by the user to automatically perform the backwash
function according to the desired interval.
• Bayonet fitting simplifies upgrade to automatic backwash.
• 16 field-selectable backwash intervals (from every four minutes to
once every three months) eliminate need for external timer.
• Connections for external control on the MV876 provide for use in
automated systems and differential pressure control.
• MV876 can be manually activated to initiate backwash.

Building Automation
• Battery (AA) backup to insure completion of backwash cycle in spite
of power loss.

Dimensions, Approximate: 6 in. high, 2-3/4 in wide, 6-5/16 in. deep


(152 mm high, 70mm wide, 160 mm deep)
Electrical Ratings: 24 Vac, 10 W

Cycle

Components
Commercial
Interval Electrical Time Battery
Product Number Backwash Intervals Selection Display Connections (sec) Back-up Description
MV876B1018 16 Adjustable intervals 16 field selectable Digital Remote 20 sec Yes, 4xAA Automatic backwash control, fits 1/2 in.
from 4 min to 3 months. via keypad Activation to 2 in. F76S models and F74C models.

Pneumatic Controls
Industrial Combustion
Controls

70-6910 295
Float Valves
VF270 Float Valves
A ruggedly designed float valve for use in commercial and
industrial applications.

Application: With polystyrene float: water and neutral liquids; with


stainless steel float: higher temperature and corrosive liquids.
Connection Type: NPT
Dimensions, Approximate: 1 1/4 in. high x 24 in. long (32 mm high x
610 mm long)
Maximum Fluid Temperature: Polystyrene Float: 149 F, Stainless steel
Float: 194 F (Polystyrene Float: 65 C, Stainless steel Float: 90 C)
Maximum Operating Pressure: With Normal Float Size 90 psi (With
Normal Float Size 621 kPa); Next Larger Float: 120 psi (Next Larger
Float: 827 kPa)

Polystyrene Float Stainless Steel Float

Pipe Size Capacity Materials


Product Number DN (inch) (Cv) (Body) (Float) (Rod) Description
VF270C1003 DN15 1/2 in. 2.3 Cv Bronze and Brass Polystyrene or Stainless Steel Hot dip galvanized steel 1/2 inch Float Valve
VF270C1011 DN20 3/4 in. 4.2 Cv Bronze and Brass Polystyrene or Stainless Steel Hot dip galvanized steel 3/4 inch Float Valve
VF270C1019 DN25 1 in. 6.4 Cv Bronze and Brass Polystyrene or Stainless Steel Hot dip galvanized steel 1 inch Float Valve
VF270C1027 DN32 1 1/4 in. 10.9 Cv Bronze and Brass Polystyrene or Stainless Steel Hot dip galvanized steel 1-1/4 inch Float Valve
VF270C1035 DN40 1 1/2 in. 15.1 Cv Bronze and Brass Polystyrene or Stainless Steel Hot dip galvanized steel 1-1/2 inch Float Valve
VF270C1043 DN50 2 in. 20.3 Cv Bronze and Brass Polystyrene or Stainless Steel Hot dip galvanized steel 2 inch Float Valve

Polystyrene Float
A float for use with VF270 float valves. Made of stainless steel or Application: For water and neutral liquids
styrofoam-filled polystyrene. Dimensions, Approximate: 8 in. diameter (203 mm diameter)
Materials (Float): Styrofoam-filled polystyrene
Maximum Fluid Temperature: 149 F (65 C)

Diameter
Product Number (inch) (mm) Description Used With
F170T1/2 5 1/8 in. 130 mm Polystyrene Float For 1/2 in., 3/4 in., 1 in. VF270 Float valves VF270
F170T1-1/4 7 7/8 in. 200 mm Polystyrene Float For 1-1/4 in., 1-1/2 in. & 2 in. VF270 Float valves VF270

Stainless Steel Floats


A float for use with VF270 float valves. Made of stainless steel or Application: For higher temperature or corrosive liquids
styrofoam-filled polystyrene. Materials (Float): Stainless steel
Maximum Fluid Temperature: 194 F (90 C)

Diameter
Product Number (inch) (mm) Description Used With
F170S104 6 in. 153 mm Stainless Steel Float for VF270 1/2 in. Float Valves VF270
F170S112 6 in. 153 mm Stainless Steel Float for VF270 3/4 in. Float Valves VF270
F170S120 7 1/4 in. 183 mm Stainless Steel Float for VF270 1 in. Float Valves VF270
F170S128 7 1/4 in. 183 mm Stainless Steel Float for VF270 1 1/4 in. Float Valves VF270
F170S136 9 1/4 in. 233 mm Stainless Steel Float for VF270 1 1/2 in. Float Valves VF270
F170S144 9 1/4 in. 233 mm Stainless Steel Float for VF270 2 in. Float Valves VF270

Parts and Accessories for Float Valves


OS Number Description
2228400 Replacement seat disc for 1/2 in. VF270C.
2228500 Replacement seat disc for 3/4 in.VF270C.
2228600 Replacement seat disc for 1 in. VF270C.

296 customer.honeywell.com 70-6910


Commercial Mixing Valves
MX Series Large Flow Proportional Mixing or Diverting Valve.

Controls
Home
Protects People and Equipment, Saves Energy
The MX Series is a state-of-the-art mixing valve with Teflon wear
surfaces to prevent calcium buildup. Valve controls hot and cold
supply based on control setting. If cold water is shut off, the valve
® will reduce the mixed flow rate in seconds (speed/residual flow
rate varies by size). Accurate control of temperature provides

Indoor Air Quality


C US energy savings, increased comfort and safety for the user.
• Dual purpose mixing or diverting valve.
• Constant water temperature under different operating conditions.
• Proportional valve (control of hot and cold water).
• Flow reduction in seconds if cold water supply is interrupted.
• Maintains temperature with extremely low minimum flows.
• Temperature adjustable, tamper evident.
• Install in any position, heat trapping not required.
• Recirculation connection for fast response.

Combustion Controls
Threaded Valves • Bronze/stainless construction.
• Wear surfaces Teflon coated to prevent deposit build-up.

Residential
• Union/tailpiece connections included.
• Tapped flange connections 2-1/2 in. and 3 in.
Flanged Valves • Allen wrench for temperature adjustment included.
• ASSE 1017 and CSA listed (Union Models)

Threaded Valves dimensions in inches (millimeters) Flanged Valves dimensions in inches (millimeters)

Hydronic Controls
D MINIMUM
SIZE SIZE
D MINIMUM

H M
SIZE
C

Water Controls
A

SIZE MX131-132
A B
A B MX127-130 C

Building Automation
C
Product Size Recir Port Dimensions Inches (mm)
Number NPT Size A B C D
Product Size Recir Port Dimensions (Inches)
Number NPT Size A B C D MX131 2-1/2” Flange 1 (25) 5-45/64 (145) 5-45/64 (145) 11-13/32 (290) 4 (102)
MX132 3” Flange 1-1/4 (32) 6-7/64 (155) 6-7/64 (155) 12-13/64 (310) 4 (102)
MX127 1” 1/2 (13) 2-51/64 (71) 3-45/64 (94) 6-1/2 (165) 6 (152)
M27479
MX128 1-1/4” 1/2 (13) 3-19/64 (84) 4-13/32 (112) 7-45/64 (196) 6-29/32 (175)
MX129 1-1/2” 1/2 (13) 3-19/32 (91) 5 (127) 8-19/32 (218) 7 (178)
MX130 2” 1/2 (13) 4-13/64 (107) 5-51/64 (147) 10 (254) 7-19/64 (211) Application: Any application requiring accurate control of hot water
temperature based on the mixing of hot and cold water, such as:
MX127C 1” 1/2 (13) 2-51/64 (71) 3-45/64 (94) 6-1/2 (165) 6 (152) domestic water for homes, apartment, hotels, schools, nursing homes,
MX128C 1-1/4” 1/2 (13) 3-19/64 (84) 4-13/32 (112) 7-45/64 (196) 6-29/32 (175) offices, public facilities, space heating, radiant floor heating,

Components
Commercial
MX129C 1-1/2” 1/2 (13) 3-19/32 (91) 5 (127) 8-19/32 (218) 7 (178)
MX130C 2” 1/2 (13) 4-13/64 (107) 5-51/64 (147) 10 (254) 7-19/64 (211) Weight: 3.6 lb
M23243B

Pipe Size Operating Temperature Range


Product Number (inch) DN Connection Type Capacity (Cv) (F) (C) ASSE
MX127 1 in. DN25 NPT 4 Cv 110 F to 150 F 43 C to 66 C 1017
Pneumatic Controls

MX127C 1 in. DN25 NPT 4 Cv 90 F to 120 F 32 C to 49 C 1017


MX128 1 1/4 in. DN32 NPT 9.3 Cv 110 F to 150 F 43 C to 66 C 1017
MX128C 1 1/4 in. DN32 NPT 9.3 Cv 90 F to 120 F 32 C to 49 C 1017
MX129 1 1/2 in. DN40 NPT 13.5 Cv 110 F to 150 F 43 C to 66 C 1017
MX129C 1 1/2 in. DN40 NPT 13.5 Cv 90 F to 120 F 32 C to 49 C 1017
MX130 2 in. DN50 NPT 18 Cv 110 F to 150 F 43 C to 66 C 1017
Industrial Combustion

MX130C 2 in. DN50 NPT 18 Cv 90 F to 120 F 32 C to 49 C 1017


Controls

MX131 2 1/2 in. DN65 Flanged 34 Cv 110 F to 150 F 43 C to 66 C —


MX132 3 in. DN80 Flanged 50 Cv 110 F to 150 F 43 C to 66 C —

70-6910 297
Commercial Mixing Valves
MX Series Valves Replacement Parts
Pipe Size
Product Number (inch) DN Description
MX100-RP 1 in. DN25 1 inch Gasket Kit for MX Series mixing valves
MX125-RP 1 1/4 in. DN32 1 1/4 inch Gasket Kit for MX Series mixing valves
MX150-RP 1 1/2 in. DN40 1 1/2 inch Gasket Kit for MX mixing valves
MX200-RP 2 in. DN50 2 inch Gasket Kit for MX mixing valves
MX250-RP 2 1/2 in. DN65 2 1/2 inch Gasket Kit for MX mixing valves
MX300-RP 3 in. DN80 3 inch Gasket Kit for MX mixing valves

Mixing Valve Accessories


Pipe Size
Product Number (inch) DN Description
MX050-RP 1/2 in. DN15 1/2 inch Recirculation adapter kit. Includes 1/2 inch MNPT union nut and gasket

298 customer.honeywell.com 70-6910


Excel 5000 System

Controls
Home
EXCEL 5000 SYSTEM ARCHITECTURE

WORK STATIONS

Indoor Air Quality


ETHERNET TCP/IP

HONEYWELL
SERVER
OTHER OPEN SYSTEMS
INTERNET/
BACNET/OPC/MODBUS
INTRANET

i.LON 600
Q7751G

Combustion Controls
WEB ACCESS
VIA BROWSER

Residential
LONWORKS BUS
ROUTER Q7751A
NETWORK INTERFACE • USE WHEN MULTIPLE
Q7751C PCLTA 20B OR NEWORKS EXIST
Q7751H PCLTA 21B
XPC 500
3RD PARTY

Hydronic Controls
LON DEVICES
• PROVEN PID SPACE TEMPERATURE
CENTRAL PLANT CONTROLLERS CONTROL ALGORITHM
MODEM • INTEGRAL OR PACKAGED ECONOMIZER
CONTROL
HONEYWELL MODEM • SEPARATE INTELLIGENT RECOVERY
C-BUS RATES FOR HEATING AND COOLING
DEVICESA • DEMAND LIMIT CONTROL TEMPERATURE
SETPOINT IN ENERGY SAVING DIRECTION
EXCEL 50
CONTROLLER
• PRESSURE-INDEPENDENT OR PRESSURE-
DEPENDENT VAV BOX CONTROL
• SINGLE-DUCT/DUAL-DUCT VAV BOX
CONTROLSOLUTIONS

Controls
• REHEAT AND PERIPHERAL RADIATION

Water
CONTROL (SELECTABLE ÒFIRST ONÓ
MODEM
SEQUENCING)
• SERIES/PARALLEL FAN
DISTRIBUTED INPUT/ • SUPPLY/RETURN AIR TRACKING
OUTPUT MODULES EXCEL 800
CONTROLLER • SPACE OR RETURN AIR TEMPERATURE
CONTROL
• ASHRAE CYCLES 1, 2, 3

Building Automation
• UP TO 4 STAGES OF HEATING
• UP TO 4 STAGES OF COOLING
• PACKAGED OR FLOATING DAMPER
CONSTANT CONTROL
ZONE CONTROLLERS VOLUME • 2 PIPE, 4 PIPE FAN COIL UNIT CONTROL
AHU • UP TO 3 SPEED FAN CONTROL
CONTROLLER • WITH OR WITHOUT ELECTRICAL REHEAT
W7750 • SPACE FREEZE PROTECTION

VAV BOX • GENERIC I/O FOR LIGHTING, EXHAUST


CONTROLLER FANS, PUMPS AND MORE
W7751 • *LONMARK¨ STANDARD OBJECTS
UNIT
VENTILATOR FOR SENSORS AND ACTUATORS

Components
Commercial
CONTROLLER
W7753
• ONE THERMOSTAT MODEL FOR EITHER
FAN COIL UNIT HEAT PUMP OR CONVENTIONAL RTU
CONTROLLER • UP TO THREE STAGES OF HEAT AND COOL
W7752 • WORKS WITH T7047 REMOTE
REMOTE TEMPERATURE SENSOR
INPUT/OUTPUT • PROPORTIONAL PLUS INTEGRAL CONTROL
DEVICE ELIMINATES TEMPERATURE FLUCTUATIONS
• 7 DAY PROGRAMMING – 2 OCCUPIED/
Pneumatic Controls

W7761
2 UNOCCUPIED PERIODS PER DAY
COMMUNICATING • DISCHARGE AIR SENSING CAPABILITY WITH
THERMOSTAT C7046C SENSOR
T7350H

HYDRONIC • RADIATORS, INDUCTION UNITS AND FAN


CONTROLLER COIL UNITS WITH MANUAL FAN SWITCHING
W7762/3 • HIGH EFFICIENCY, LOW COST HEAT/COOL
VALVE APPLICATION SOLUTION
• MODEL WITH INTEGRATED OR REMOTE
MODULE FOR WALL OR UNIT MOUNTED
Industrial Combustion

A PLANT CONTROLLERS MAY BE CONFIGURED TO COMMUNICATE ON THE LONWORKS BUS FOR


OPEN SYSTEM JOBS OR THE HONEYWELL C-BUS.
B THE SYSTEM ONLY REQUIRES THE i.LON 600 OR THE PCLTA FOR EACH APPLICATION, NOT BOTH. M23221B
Controls

70-6910 299
Excel 5000 System
Controller Tools
software validates as the designer works, thus keeping the
process free of errors. Work is completed quickly and efficiently.
As part of the design process, CARE automatically creates
comprehensive documentation and materials listings.
NOTE: All CARE products require a signed SOFTWARE LICENSE
AGREEMENT prior to purchase. Ordering CARE via this website
does not guarantee that you are approved for the purchase.
Honeywell reserves the right to refuse shipment, if appropriate.
• Point-and-click programming
• Schematic drawing
• Control strategy
• Switching logic
• Time function
• Mathematical editor
• Standard library.
• Documentation
The Excel CARE and Live CARE software packages are graphic • Control program simulation
tools to easily and quickly create and simulate application • Applicable to EXCEL 5000 System controllers
programs that run controllers in EXCEL 5000® Systems. Users can • Password security
perform these functions without extensive knowledge of a
programming language. Users systematically select control Application: Tool
system graphic elements such as lighting and Heating, Ventilating, Application Size: Small to Large
and Air Conditioning (HVAC) equipment and create control Building Management Interface: EBI; SymmetrE; XBS
sequences in a Microsoft® Windows® environment. CARE Network Communications: C-Bus; LonWorks Bus
Compatible with: Excel 5000 System Controllers

Commissioning
Product Number Description Software Output Type Used With Includes
CARE-80-LNS CARE: Graphic CARE Graphical Interface Excel 5000 System USB Drive with full installation of
Programming Tool Controllers CARE 8 with voucher number
PROTPLUG-UP CARE: Graphic CARE Graphical Interface Excel 5000 System USB Drive with CARE 8 upgrade
Programming Tool Upgrade Controllers

SymmetrE
The Honeywell SymmetrE™ building management system SymmetrE™ integrates using Open System Standards and Internet
redefines what to expect from monitoring and control of your and Intranet applications. This allows you to choose the best field
heating, ventilation and air conditioning equipment. The scalable, solutions for your building and to integrate information into
open SymmetrE™ system brings your building's occupant needs, SymmetrE™ seamlessly for further processing, reporting and
operational issues and budget pressures into perfect balance. You distribution. SymmetrE™ provides operators, supervisors, and
get an unparalleled solution that helps simplify facility managers with a sophisticated web-style operator interface to
management, boost productivity and reduce costs. NOTE: All enable personnel to easily monitor and control buildings at one or
CARE products require a signed SymmetrE™ LICENSE more sites.
AGREEMENT prior to purchase. Ordering SymmetrE™ via this The SymmetrE™ Server runs on the multi-user, multi tasking,
website does not guarantee that you are approved for the industry standard, Windows 2000 Professional and Windows XP
purchase. Honeywell reserves the right to refuse shipment, if Professional platforms. The SymmetrE™ Server runs application
appropriate. software that communicates to field controllers and updates a real
The Honeywell SymmetrE™ PC workstation redefines what to time database. The SymmetrE™ Server can also act as the file
expect from monitoring and controlling your building management server for displays and historical data collection and archiving.
system. The scalable, open SymmetrE™ software brings your • Total solution for Heating, Ventilation & Air conditioning Building
building's occupant needs, operational issues and budget Management Systems.
pressures into perfect balance. You get an unparalleled solution • Integration with a diverse range of devices, Internet and Intranet
that helps simplify facility management, boost productivity and sources allowing intelligent management of key facility information.
reduce costs. • Uses Industry standard hardware and Windows® 2000 Professional
NOTE: All SymmetrE™ products require a signed SymmetrE™ and Windows XP® Professional Operating Systems
LICENSE AGREEMENT prior to purchase. Ordering SymmetrE™ • Supports the leading open standards: BACnet®, LONMARK®,
via this website does not guarantee that you are approved for the ODBC, OPC®, AdvanceDDE and Modbus®.
purchase. Honeywell reserves the right to refuse shipment, if • Easy-to-use web-style interface reduces operator training costs and
appropriate. puts the user in control of every situation.
• Designed and developed to International Standard ISO® 9001:2000
SymmetrE™ is a highly configurable PC workstation providing an for quality assurance.
efficient and reliable way of ensuring the comfort of people and the
effective operation of buildings and facilities. Used with the Excel Application: Workstation Software
5000 Building Management System it provides a complete solution Building Management Interface: SymmetrE
to access information and the control needs of one or more
buildings.

SymmetrE R410 - Software/Media


Product Number Description
SYM-BASE01 SymmetrE R410 Base Package 1
SYM-BASE02 SymmetrE R410 Base Package 2
SYM-BASE03 SymmetrE R410 Base Package 3
SYM-ZZDVD410 SymmetrE R410 Software on DVD

300 customer.honeywell.com 70-6910


Excel 5000 System
SymmetrE R410 - Upgrades

Controls
Home
Product Number Description
SYM-UPGDR1 SYM Upgrade Unit - Release Minus 1
SYM-UPGDR2 SYM Upgrade Unit - Release Minus 2
SYM-UPGDR3 SYM Upgrade Unit - Release Minus 3

Indoor Air Quality


SYM-UPGDRX SYM Upgrade Unit - Release Minus X

SymmetrE R410 - Options


Product Number Description
SYM-DBP00250 250 Point Adder to Database Size
SYM-OPEASYMB Easy Mobile Services
SYM-IF-BACNET BACnet Client (R200 and later)

Combustion Controls
SYM-IF-MODBUS Modbus Interface

Residential
SYM-IF-OPCCL OPC Client Interface
SYM-IF-XL5DIRDIAL EXCEL 5000 Dial-up
SYM-NW-OPCSERV OPC Server
SYM-OP-ALMPAG Alarm Pager
SYM-OP-BACSERV BACnet Server (R200 and later)
SYM-OP-DTXL OPC Data Transfer - Local

Hydronic Controls
SYM-OP-LNS LNS Server
SYM-OP-LNSUPG LNS Database Upgrade for systems with existing LNS Database

SymmetrE R310 Workstation


Product Number Description
SYM-DB2-5-EXP Expansion Pack - 250 to 500 point DB
SYM-DB5-10-EXP Expansion pack - 500 to 1000 Point DB
SYM-DB10-20-EXP Expansion pack - 1000 to 2000 Point DB

Controls
Water
SYM-DB20-35-EXP Expansion pack - 2000 to 3500 Point DB
SYM-DB35-50-EXP Expansion pack - 3500 to 5000 Point DB
SYM-DB50-75-EXP Expansion pack - 5000 to 7500 Point DB
SYM-DB75-10K-EXP Expansion Pack - 7500 to 10,000 point DB
SYM-DB10K-15K-EXP Expansion Pack - 10,000 to 15,000 point DB

Building Automation
SYM-DB15K-20K-EXP Expansion Pack - 15,000 to 20,000 point DB
SYM-IF-ADVDDECL Advance DDE Interface
SYM-IF-BAC BACnet Client (R200 and later)

SymmetrE R310 - Options


Product Number Description
SYM-IF-BACNET BACnet Client (R200 and later)

Components
Commercial
SYM-IF-MODBUS Modbus Interface
SYM-IF-OPCCL OPC Client Interface
SYM-IF-XL5DIRDIAL EXCEL 5000 Dial-up
SYM-NW-OPCSERV OPC Server
SYM-OP-ALMPAG Alarm Pager
SYM-OP-BACSERV BACnet Server (R200 and later)
Pneumatic Controls

SYM-OP-DTXL OPC Data Transfer - Local


SYM-OP-LNS LNS Server
SYM-OP-LNSUPG LNS Database Upgrade for systems with existing LNS Database
SYM-STB-UP-STN Upgrade Browser client to full station client, R310 ONLY
Industrial Combustion
Controls

70-6910 301
Excel 5000 System
Excel 800 Controller
With more power and fewer pieces to buy, the new Excel 800
Controller is the plant controller you can count on for years to
come. Along with easy programming and extensive memory, it
offers all the flexibility you’ve come to depend on from the
Honeywell Excel 5000 product line. Best of all, you won’t have to
learn any new programming, because your old Excel 500
application programs work perfectly with the Excel 800 controller.
• Double the memory
• Reduced training needs, use your current Excel 500 application
programs
• Hot-swappable replacement of defective I/O modules
• Easy-Access Terminals
• Simplified Installation

Building Management Interface: EBI; SymmetrE; ACSELON Shipping Temperature Range: -4 F to +158 F (-20 C to +70 C)
Voltage: 24 Vac/dc, ± 20%
Approvals:
Frequency: 50 Hz; 60 Hz Underwriters Laboratories, Inc. UL 916
Commissioning Software: CARE 8
Operating Humidity Range (% RH): 5 to 93% RH, non-condensing

CPU Modules
Network Communications: C-Bus; LonWorks Bus
Power Consumption: Max 5 VA (max. 4 W)

Approvals:
Underwriters
Product Number Application Description Output Type Comments Laboratories, Inc.
XCL8010A Freely Programmable; Boiler; Excel 800 Control Analog/Modulating; Pulse Width CPU Module UL 916
Discharge Air; Cooling Tower; Chiller; System Modulation; Floating; Staged On/Off
Hydronic; Built-up AHU
XCL8010AU Freely Programmable; Boiler; Excel 800 Control Analog/Modulating; Pulse Width CPU Module UL916 and UL864
Discharge Air; Cooling Tower; Chiller; System Modulation; Floating; Staged On/Off
Hydronic; Built-up AHU

Input Output Modules


Network Communications: Panel Bus
Used With: Excel 800 Controller

Approvals: Underwriters
Product Number Application Description I/O Count Laboratories, Inc.
XF821A Input Module Analog Input Module 8 analog input module (Panel) UL916
XF821AU Input Module Analog Input Module 8 analog input module (Panel) UL916 and UL864
XF822A Output Module Analog Output Module 8 AO with override (Panel) UL916
XF822AU Output Module Analog Output Module 8 AO with override (Panel) UL916 and UL864
XF823A Input Module Digital Input Module 12 binary input module (Panel) UL916
XF823AU Input Module Digital Input Module 12 binary input module (Panel) UL916 and UL864
XF824A Output Module Digital Output Module 6 relay output module (Panel) UL916
XF824AU Output Module Digital Output Module 6 relay output module (Panel) UL916 and UL864

302 customer.honeywell.com 70-6910


Excel 5000 System
Excel Distributed I/O

Controls
Home
With more power and fewer pieces to buy, the new Excel 800
Controller is the plant controller you can count on for years to
come. Along with easy programming and extensive memory, it
offers all the flexibility you’ve come to depend on from the
Honeywell Excel 5000 product line. Best of all, you won’t have to
learn any new programming, because your old Excel 500
application programs work perfectly with the Excel 800 controller.

Indoor Air Quality


• Double the memory
• Reduced training needs, use your current Excel 500 application
programs
• Hot-swappable replacement of defective I/O modules
• Easy-Access Terminals
• Simplified Installation

Application: Distributed I/O


Building Management Interface: EBI; SymmetrE; ACSELON

Combustion Controls
Commissioning Software: CARE 8
Used With: Excel 800 Controller

Residential
Approvals:
Network Underwriters

Hydronic Controls
Product Number Description Communications I/O Count Comments Laboratories, Inc.
XFL821A Distributed I/O - Analog LonWorks Bus 8 analog input module — UL916
input module (LON)
XFL821AU Distributed I/O - Analog LonWorks Bus 8 analog input module — UL916 and UL864
input module (LON)
XFL822A Distributed I/O - Analog LonWorks Bus 8 analog output module — UL916
output module (LON)
XFL822AU Distributed I/O - Analog LonWorks Bus 8 analog output module — UL916 and UL864
output module (LON)

Controls
Water
XFL823A Distributed I/O - Digital LonWorks Bus 12 binary input module Includes 12 LEDs UL916
input module (LON)
XFL823AU Distributed I/O - Digital LonWorks Bus 12 binary input module Includes 12 LEDs UL916 and UL864
input module (LON)
XFL824A Distributed I/O - Digital LonWorks Bus 6 relay output module — UL916
output module (LON)

Building Automation
XFL824AU Distributed I/O - Digital LonWorks Bus 6 relay output module — UL916 and UL864
output module (LON)
XFLR822A Analog output manual LonWorks Bus 8 AO with override (LON) The manual override module works UL916
override module even if the CPU is not working.
XFLR822AU Analog output manual LonWorks Bus 8 AO with override (LON) The manual override module works UL916 and UL864
override module even if the CPU is not working.
XFLR824A Digital output manual LonWorks Bus 6 relays with override The manual override module works UL916
override module (LON) even if the CPU is not working.
XFLR824AU Digital output manual LonWorks Bus 6 relays with override The manual override module works UL916 and UL864

Components
override module (LON) even if the CPU is not working.

Commercial
XFR822A Analog output manual Panel Bus 8 AO with override The manual override module works UL916
override module (Panel) even if the CPU is not working.
XFR822AU Analog output manual Panel Bus 8 AO with override The manual override module works UL916 and UL864
override module (Panel) even if the CPU is not working.
XFR824A Digital output manual Panel Bus 6 relays with override The manual override module works UL916
override module (Panel) even if the CPU is not working.
Pneumatic Controls

XFR824AU Digital output manual Panel Bus 6 relays with override The manual override module works UL916 and UL864
override module (Panel) even if the CPU is not working.
XFR825A Actuator output module Panel Bus Actuator output module — UL916
(Panel)
XFR825AU Actuator output module Panel Bus Actuator output module — UL916 and UL864
(Panel)
Industrial Combustion
Controls

70-6910 303
Excel 5000 System
Excel 100 Controller
The Excel 100 Controllers are direct-digital control,
microprocessor-based, programmable controllers that manage
building functions.
• Stand-alone or networked operation for flexible use or expansion.
• CARE generated application programs for comprehensive control
strategies.
• Analog or digital inputs and outputs for flexible point use.
• Multiple operator interface options for local or easy on-site changes.
• Point trending for timely information.
• Alarm handling facility to locally display the problem and remote dial
out to act on it.
• Battery-backed RAM data to keep controller programming in place
during power outage.
• Bus-Wide MMI provides local viewing/modification of point
information of all controllers attached to the Communication Bus.

Dimensions, Approximate: 9.25 in. high x 7.56 in. wide x 2.83 in. deep Operating Humidity Range (% RH): 5 to 90% RH, non-condensing
(235 mm high x 192 mm wide x 72 mm deep) Shipping Temperature Range: -4 F to +140 F (-20 C to +60 C)
Application: Programmable Controller
Approvals:
Building Management Interface: EBI; SymmetrE; ACSELON CE: Approved
Commissioning Software: CARE Federal Communications Commission: Meets FCC Part 15, Subpart
Voltage: 24 Vac/Vdc J for Class A equipment
Frequency: 50 Hz; 60 Hz Underwriters Laboratories, Inc. Form UL916
Power Consumption: 25 VA Max.
Operating Temperature Range32 F to 122 F: (0 C to 50 C)

Network
Product Number Description Communications I/O Count Output Type Comments
XL100CU Freely Programmable DDC C-Bus 12 UO; 0-10 Vdc, 20mA —
controller 12 UI; 12 DI
XL100CUUKL Freely Programmable, for C-Bus 12 UO; 0-10 Vdc, 20mA UUKL approval for use
Smoke & Fire (Europe) 12 UI; 12 DI on fire systems

Excel 50 Controllers
A compact, programmable controller that manages small building
control applications. Available with or without operator interface.
Provides perfect solution for managing small building control
applications and HVAC equipment control applications.
• Direct communication to C-bus & LonWorks bus and/or modems.
• DIN rail or panel door mounting.
• Available with or without operator interface.
• Stand-alone or networked operation.
• CARE-generated application programs; ability to reuse available
CARE applications.
• Flash-EPROM for efficient downloads.
• Wiring simplicity: accessible and removable screw terminal blocks.
• Capacitor-backed RAM; no battery required.

Dimensions, Approximate: 5.90 in. high x 7.79 in. wide x 3.19 in. deep Operating Temperature Range: 32 F to 122 F (0 C to 50 C)
(150 mm high x 198 mm wide x 81 mm deep) Operating Humidity Range (% RH): 5 to 93% RH, non-condensing
Application: Built-up AHU, Chiller, Cooling Tower, Boiler, Freely Shipping Temperature Range: -4 F to +158 F (-20 C to +70 C)
Programmable
Approvals:
Building Management Interface: EBI; SymmetrE; ACSELON CE: Approved
Commissioning Software: CARE Federal Communications Commission: Meets FCC Part 15, Subpart
Voltage: 24 Vac ± 20% J for Class A equipment
Frequency: 50 Hz; 60 Hz Underwriters Laboratories, Inc. Form UL916
Power Consumption: 72 VA, if fully equipped

Network
Product Number Description Communications I/O Count Output Type Comments Includes
XL50A-UMMIPCCBLON Freely Programmable C-Bus; LonWorks 4 DI, 8 UI, Analog/Modulating; Includes C-Bus/LonWorks Bus
DDC controller, with Bus 4 UO, 6 DOs Pulse Width Modulation; Operator communication card
operator interface Floating; Staged On/Off Interface
XL50A-UPCCBLON Freely Programmable C-Bus; LonWorks 4 DI, 8 UI, Analog/Modulating; Does not have C-Bus/LonWorks Bus
DDC controller Bus 4 UO, 6 DOs Pulse Width Modulation; Operator communication card
Floating; Staged On/Off Interface

304 customer.honeywell.com 70-6910


Excel 5000 System
Excel Smart I/O

Controls
Home
Excel Smart I/O modules feature a variety of software-configurable
digital and analog inputs and outputs and are suitable for
installation at strategic locations throughout your buildings. The
modules convert physical input signals from sensors into network
variables and the network variables into physical output signals
for operating actuators.
• Flexible, software-configurable inputs/outputs.

Indoor Air Quality


• Flash memory for downloading applications.
• 2-wire FTT-10A LonWorks bus interface.
• Easily-accessible service button and a service LED.
• DIN rail mounting and wall-mounting supported.

Combustion Controls
Dimensions, Approximate: 5 in. wide x 3 in. length x 4.33 in. high Operating Temperature Range: 32 F to 122 F (0 C to 50 C)

Residential
(126 mm wide x 76 mm length x 110 mm high) Operating Humidity Range (% RH): 5 to 90% RH, non-condensing
Application: Configurable I/O Shipping Temperature Range: -22 F to +158 F (-30 C to +70 C)
Building Management Interface: EBI; SymmetrE; ACSELON
Approvals:
Commissioning Software: CARE CE: CE and EN 50081-1, LonMark Application Layer Guidelines
Voltage: 24 Vac Version 3.2
Frequency: 50 Hz; 60 Hz

Hydronic Controls
Network
Product Number Description Communications I/O Count Includes
XFC3A04001 Smart I/O module. Lonmark certified. Fixed terminals LonWorks 2 UI; 2 AO; 4 DI —
XFC3A06001 Smart I/O module. Lonmark certified. Fixed terminals LonWorks Bus 4 UI; 2 AO; 4 DI —
XFC3D06001 Smart I/O module with Removable terminals, Lonmark LonWorks Bus 4 UI: 2 AO: 4 DI Six 3-position manual overrides and
Certified 10 colored status LEDs

Compact I/O

Controls
The Honeywell Compact I/O are LON modules with a certain

Water
number of digital inputs, analog inputs, digital outputs, analog
outputs, and hubs used to record or control network variable
points (SNVT’s) on a LonWorks bus.
• Configured via LNS Plug-in.
• Easy Installation saves time and money.
• Easy to expand.
• Compact Design.

Building Automation
Dimensions, Approximate: 1.4 in. wide x 2.8 in. high x 2.6 in. deep
(35 mm wide x 71 mm high x 66 mm deep)
Application: Input/Output Module
Commissioning Software: LNS Plug-in
Network Communications: LonWorks Bus
Voltage: 20 - 28 V AC/DC
Operating Temperature Range: 23 F to 131 F (-5 C to 55 C)
Shipping Temperature Range: -4 F to +158 F (-20 C to 170 C)
Compatible with: Compact I/O Family

Components
Commercial
Approvals:
CE: Approved
Underwriters Laboratories, Inc. UL 916

Product Number Description I/O Count Power Consumption


XIO-10DI Digital Input Module with 10 Inputs 10 DI 63 mA (AC)/21 mA (DC).
XIO-10HUB I/O Module Expander Hub — —
Pneumatic Controls

XIO-4AO Analog Output Module with 4 Outputs 4 AO 150 mA (AC)/70 mA (DC).


XIO-4DI Digital Input Module with 4 Inputs 4 DI 63 mA (AC)/21 mA (DC).
XIO-4DO Digital Output Module with 4 Outputs 4 DOs 205 mA (AC)/67 mA (DC).
XIO-4NTC Analog Input Module with 4 NTC Sensor Specific Inputs 4 NTC Sensor Specific Inputs 67 mA (AC)/24 mA (DC).
XIO-4PT1000 Analog Input Module with 4 PT1000 Sensor Specific Inputs 4 PT1000 Sensor Specific Inputs 67 mA (AC)/24 mA (DC).
XIO-8AI Analog Input Module with 8 Inputs 8 AI 57 mA (AC)/30 mA (DC).
Industrial Combustion
Controls

70-6910 305
Excel 5000 System
LonWorks Bus Accessories
Product Number Description Used With
Q7740A1008 Two way repeater with connections for two network segments LonMark Controllers

Q7740B1006 Four way repeater with connections for four network segments LonMark Controllers

Q7750A2003 Excel 10 Zone Manager LonMark Controllers

Q7751A2010 Excel 10 router used for connection with four network segments, LonMark Controllers
FT-10/FT-10

Q7751A2028 Excel 10 router used for connection with four network segments, LonMark Controllers
TP-1250/FT-10

Q7751E1005 I.LON 10-TP/FT - 10 CHANNEL LonMark Controllers


Q7751F1011 I.LON 100 - TP/FT - 10 NO MODEM Firmware version e3 LonMark Controllers

Q7751F1029 I.LON 100 - TP/FT - 10 With MODEM Firmware version e3 LonMark Controllers

Q7751G2009 I.LON 600 FT - 10 LonMark Controllers

Q7751G2017 I.LON 600 XF1250 LonMark Controllers

Q7751H2007 PCLTA-21/TP-1250 —

Q7751H2015 PCLTA-21/FT-10 —

Q7751J2002 MPR-50 Multi-Port Router —

306 customer.honeywell.com 70-6910


Excel 5000 System

Controls
Product Number Description Used With

Home
Q7752B2009 Serial LonTalk Adapter, FTT-10A LonMark Controllers

Q7752C2007 U10 - USB Network Interface with Cable —

Indoor Air Quality


Excel 5000® Accessories

Combustion Controls
Residential
Product Number Description Used With
14005680-089596 XL5000 fiber optic interface for C-Bus —

Hydronic Controls
14500087-004 Dpdt relay with 12 Vdc coil, switches 120 Vac or 28 Vdc @ 3 amps, used 14507222
with 14507222 Relay for XL100 Controller

Controls
Water
14506747-001 sub-panel for half sized cabinet Panels

Building Automation
14506747-002 sub-panel for full sized cabinet Panels

Components
14507063-002 Power Supply Cable To Connect Power To Excel Controller Excel 5000 System Commercial
Controllers
Pneumatic Controls

14507063-003 Power Supply Cable (Tinned Ends) To Connect Power Module To Excel Excel 5000 System
Controller Controllers
Industrial Combustion
Controls

70-6910 307
Excel 5000 System
Product Number Description Used With
14507222-001 Relay Module, Four Relays. Includes Hand-Off-Auto Switches and LEDs Excel 500/600 Controller;
Excel 100B

14507222-002 Relay Module, Four Relays. Includes LEDs 14507222

14507287-001 Power Module, 120 Vac Input, 50 VA Controller Transformer with Excel 5000 System
Convertible Outlet and Breaker Controllers

14507287-002 Power Module, 120 Vac Input, 50 VA Controller Transformer Plus 100 Excel 5000 System
VA Accessory Transformer With Convertible Outlet and Breaker Controllers

14507287-003 Power Module, 120 Vac Input, 50 VA Controller Transformer Plus 100 Excel 5000 System
VA Accessory Transformer and 24 Vdc Accessory Transformer With Controllers
Convertible Output and Breaker

14507287-004 Power Module, 220/240 Vac Input, 50 VA Controller Transformer, with Excel 5000 System
Convertible Outlet and Breaker Controllers

14507287-005 Power Module, 220/240 Vac Input, 50 VA Controller Transformer Plus Excel 5000 System
100 VA Accessory Transformer with Convertible Outlet and Breaker Controllers

14507287-006 Power Module, 220/240 Vac Input, 50 VA Controller Transformer Plus Excel 5000 System
100 VA Accessory Transformer and 24 Vdc Accessory Transformer with Controllers
Convertible Outlet and Breaker

14507287-007 50 VA Excel 5000 access power module for Excel 5000 applications Excel 5000 System
Controllers

308 customer.honeywell.com 70-6910


Excel 5000 System

Controls
Product Number Description Used With

Home
14507324-001 High speed, c-bus network repeater, panel mount (without cover) to Excel 5000 System
extend bus length. Controllers

Indoor Air Quality


14507324-002 High speed, c-bus network repeater, field mount (with cover) to extend Excel 5000 System
bus length. Controllers

Combustion Controls
Residential
14507547-001 C-bus to DB-25 connector cable, to connect internal RS-485 adapter Excel 5000 System
board to C-bus. Controllers

14507549-001 External RS-485 adaptor module to directly connect a PC to a C-bus C-Bus

Hydronic Controls
14507551-001 Cable assembly, com port to adapter module, 30 in. 14507549

Controls
Water
14507551-002 Cable assembly, com port to adapter module, 10 ft 14507549

14507552-001 Cable assembly, power to adapter module, used with C-Bus and XBS, 14507549
11 inches long

Building Automation
14507552-002 Cable assembly, power to adapter module, used with C-Bus and XBS, 14507549
15 inches long

206317A Excel 10 termination module, FTT-10 Excel 10 Controllers

Components
Commercial
207912 Track mounting for a W7751A, B Excel 10
Pneumatic Controls

209541B Terminator module for FTT network (1 required for T- Tap, Star, Mixed or Excel 10 Controllers
Loop network topologies, 2 Required for Daisy chain network topology)

32000180-004 Replacement cable for use with Q7752B2009 Q7752B2009


Industrial Combustion
Controls

70-6910 309
Excel 5000 System
Product Number Description Used With
32000180-019 Echelon power supply Excel 10 Controllers

32002516-001 Cable to connect Serial LonTalk adapter to Audio-type bus connection LonMark Controllers
on LonMark Controller

32002517-001 Cable to connect serial LonTalk adaptor to a modem. Excel 10 Controllers

EXCELon EXCELon LonWork Network Management Tool. Software License Excel 5000 System
Required. Controllers

MCE3 Relay Module, Two Spdt Outputs, One Spst Output —

XAL10 Labels (Package Of 10) Excel 800 Controller


XD50B-FCL Excel 50 Communication Card for LON and C-Bus Excel 50 Controllers

XI882-ACC Excel Touch Accessory Kit XI882


XL-ONLINE-CD Excel Online, Commissioning tool for EXCEL 5000 Controllers Excel 5000 System
Controllers
XL50ACC2 Communications boards for XL50 Communications Modules Excel 50 Controllers

XL50ACC3 Panel Mounting Kit for XL50 Excel 50 Controllers

310 customer.honeywell.com 70-6910


Excel 5000 System

Controls
Product Number Description Used With

Home
XM500-US Remote communication module, TCP/IP WAN Modem. Emulates a Excel 5000 System
Hayes compatible phone modem to convert serial data to Ethernet - Controllers
TCP/IP packets.

Indoor Air Quality


XS50 XL50 Terminal Block Set Excel 50 Controllers

XS812 Test Connector Excel 800 Distributed I/O

Combustion Controls
XS812RO Test Connector for relay outputs Excel 800 Distributed I/O
XS814 Auxiliary terminal block (10) Excel 800 Distributed I/O

Residential
XS815 Cross Connector 6 Relays (20) Excel 800 Distributed I/O
XS816 Bus Bridge (10) Excel 800 Distributed I/O
XS817 Cross Connector 3 Relays (40) Excel 800 Distributed I/O
XS821-22 Terminal socket analog modules Excel 800 Distributed I/O
XS823 Terminal socket binary input Excel 800 Distributed I/O

Hydronic Controls
XS824-25 Terminal socket relay output Excel 800 Distributed I/O
XSU821-22 Screw Terminal socket analog modules Excel 800 Distributed I/O
XSU823 Screw Terminal socket binary input Excel 800 Distributed I/O
XSU824-25 Screw Terminal socket relay output Excel 800 Distributed I/O
XW882 Cable from XI582 to XL800-RS232(RJ45) Excel 800 Distributed I/O
XW884 Adapter cable, XI582 (RJ45) to old XL500 Excel 800 Distributed I/O
XW885 Cable from PC to XL800-RS232(RJ45) Excel 800 Distributed I/O

Controls
Water
Building Automation
Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 311
WEBs-AX System
WEBs-AX SYSTEM ARCHITECTURE

WEBSTATION
WEB BROWSER
(REMOTE) · ENTERPRISE SECURITY
· ENERGY ANALYTICS
WEB BROWSER
(LOCAL)
INTERNET/
INTRANET

ETHERNET LAN HTTP, XML, BACnet, SNMP, oBIX

3RD PARTY
HVAC

SECURITY

ENERGY

VIDEO
WEB-NXS
WEB-600 IO-34-H

ELECTRICITY
SUBMETER
VAV
COMMUNICATING IP CAMERA MODBUS®
THERMOSTAT

SUBMETER WATER
AHU ENERGY
IP CAMERA
SMART VAV
ELECTRIC
SUBMETER GAS METERS
CVAHU DVR

SmartVFD
LIGHTING
COMPACT
PLANT CONTROL
PLANT
UV ANALOG CAMERAS
CONTROLLER

HVAC OPTIONS:

PROGRAMMABLE ZONE CONTROLLERS ZONE CONTROLLERS CENTRAL PLANT CONTROLLERS

PUL6438S
CONSTANT COMMUNICATING
PUL1012S T7350H EXCEL 50
VOLUME AHU THERMOSTAT
PUL4024S CONTROLLER
CONTROLLER
PUB6438S
CONSTANT
W7750 VOLUME AHU
PVL6438NS CONTROLLER
PVL4024NS VAV BOX EXCEL 800
PVB6438NS CONTROLLER CONTROLLER
VAV BOX
W7751
PVL4022AS CONTROLLER
PVL0000AS VAV BOX
PVL6436AS CONTROLLER DISTRIBUTED
PVB6436AS W/ACTUATOR INPUT/OUTPUT
FAN COIL
W7752 UNIT MODULES
CONTROLLER

UNIT
W7753 VENTILATOR
CONTROLLER

REMOTE
W7761 INPUT/OUTPUT
DEVICE

W7762 HYDRONIC
W7763 CONTROLLER

M16821B

312 customer.honeywell.com 70-6910


TM
WEBs–AX System Integration
Software Platform
HVAC Enterprise Security Combined HVAC & Security Console HVAC Tools Sec. Tool

WEB-S-AX
SEC-H-SQL

SEC-H-MYS
COMBO MYS
COMBO SQL
WEB-S-AX-W

WEB-S-AX-64
SEC-H-MT-AX

WEB-S-AX-LNX

WEB-S-AX-SBS
SEC-H-SQL-SBS

SEC-H-MYS-SBS
W-ALARM-CONSL

COMBO SQL SBS

COMBO MYS SBS


Features Part Numbers Description
Operating System c c Win 64 Linux d d d d c c c c c c c

Demo Available O O O O O
Controller Limit 3 a a a 6 3 500 500 O O
500 6 500 3
Software Drivers
Niagara Niagara Historical DB • • • • • • • • • • • •
Workbench • • • • • • • • • • • • •
Security Appliance • • • • • • • •
Communication oBIX Client/Server • • • • • • • • • • • •
Client DR-NS-OBIX-AX oBIX b O O O O O O O O
DR-NS-OBIX500 Additional 500 points O O O O O O O O
DR-NS-BAC-AX BACnet IP O O O O O O O O
DR-NS-BAC-500 Additional 500 points O O O O O O O O
DR-NS-MDB-AX MODbusTCP O O O O O O O O
DR-NS-MDB-500 Additional 500 points O O O O O O O O
DR-NS-OPC-AX OPC O O O O O O O
DR-NS-OPC-500 Additional 500 points O O O O O O O
DR-NS-SNMP-AX SNMP O O O O O O O O
DR-NS-SNMP-500 Additional 500 points O O O O O O O O
Server S-AX-BCSRV-AX BACnet IP O O O O O O O O
DB Connectivity S-DB-SQL SQL O O O • • • •

70-6910
S-DB-MYSQL MySQL O O O O • • • •
S-DB-ORCL Oracle O O O O
S-DB-DB2 DB2 O O O O
S-DB-CSV CSV O O O O
EnergyAnalytics WES-STA-AX Station O O O O O O O O
WES-PNT-AX Point O O O O O O O O
Video DR-SUP-DED-AX Dedicated Micro DVR O O O O O O O O O O O O
DR-SUP-DED-4 4 Cameras (16 max) O O O O O O O O O O O O
DR-SUP-AXS-AX Axis Cameras O O O O O O O O O O O O
DR-SUP-AXS-4 4 Cameras (16 max) O O O O O O O O O O O O
Enterprise Security SEC-H-R-16 16 Reader Pack O O O O O O O O
SEC-H-R-64 64 Reader Pack O O O O O O O O
SEC-H-R-256 256 Reader Pack O O O O O O O O
SEC-H-R-1024 1024 Reader Pack O O O O O O O O
Upgrade Options
SUP-U-AX Revision Upgrade O O O O O O O O O O O O
WEB-U-AX Revision Upgrade O O O
SBS Upgrades WEB-S-AX-SBS-EXUP SBS Upgrade O
SEC-H-SBS-U Security SBS Upgrade O O
Combo Upgrades SEC-H-SUP-SQL SBS BAS to Security/SQL O
SEC-H-SUP-MYS SBS BAS to Security/MYSQL O
SEC-H-SUP-SQL HVAC + Security/SQL O
SEC-H-SUP-MYS HVAC + Security/MYSQL O
SBS Secutity/SQL + HVAC O
SBS Secutity/MYSQL + HVAC O
SEC-H-BAS-U
Security/SQL + HVAC O
Security/MYSQL + HVAC O
a Resources and performance limits - no defined limit in license.
b oBIX connectivity for controllers NOT powered by Niagara
c
Windows Server 2003,Windows XP Pro
d Windows Server 2003,Windows XP Pro, Linux
• = Standard (included)
O = Optional (excluded)

313
WEBs-AX System

Controls Pneumatic Controls Components Building Automation Controls Hydronic Controls Combustion Controls Indoor Air Quality Controls
Industrial Combustion Commercial Water Residential Home
WEBs-AX System

TM
WEBs–AX System Integration
Integration Controller Platforms
4XX 5XX NXS 2XX 6XX 7XX Soft Security Compact

W-SJ-1M-AX

SEC-H-600

SEC-H-600
WEB-403-AX

WEB-403-EZ

WEB-403-AX-E

WEB-545-AX-E

WEB-5R-AX

W-NXS-FL

W-NXS-HD

WEB-201

WEB-600

WEB-602-XPR

WEB-700

SEC-H-201

SEC-H-600
Features Part Numbers Description
Open License O O O O O O O O O O O • •
Demo Available O O O O O O
Device Limit 27 27 a a a a a a a a a a a a 75 75
Hardware
Memory Standard RAM 128 128 256 256 256 512 512 64 128 256 512 N/A 128 256 256 256
NPM-XXX* Expandable RAM Option 128 256 1GB
Standard Flash 32 32 128 128 128 1GB ** 64 128 128 1GB N/A 64 128 128 128
Communication 10/100 Ethernet Port 1 1 1 1 1 1 1 2 2 2 2 2 2 2
1 GB Ethernet Port 2
USB 2.0 Port 2
Ports/ Slots RS-485 Port 1 1 1 4 4 1 1 1 1 1 1 1 1 1 1
RS-232 Port 1 1 1 2 2 1 1 1 1 1 1 1 1 1 1
NDIO Port 1 1
NRIO Port 1 1 1 1 1 1 1 1
LonWorks FTT-10 Port 1 1 2 1 1 1 1
Option Card Slots 2 2 1 2 2 2 2 2
ON-Board I/O Universal Inputs 6 6 6 8
Supervised Inputs 6 6 6 6
Digital Inputs 3 3 3 3
Card Readers 2 2 2 2
Relay Outputs/ Form 4C 4C 4C 4A 4C 4C 4C 4C
Analog Outputs 4
Software Drivers
Niagara EC-SP-XXX Fox Client/ Server O • O O • • • • • • • • • • • •
UI-SP-XXX Web UI O • O O • • • • • • • • • • • •
WEB-AX-EMB Embedded Workbench O O O O O O O O O O O
SecurityAppliance • • • •
Spyder DR-SPYDER-LON LON Spyder Prog. O O O O O • • • • • • • • •
DR-SPYDER-BAC BACnet Spyder Prog. O O O O O • • • • • • • • •
Communication oBIX Client/Server • • • • • • • • • • • • • • • •
Client DR-BAC-CLI-AX BACnet IP • • • • O O O O O O O • •
DR-MSTP-AX BACnet MS/TP • • • • O O O O O
DR-LONDRIV-AX LonWorks FTT10 • • • • O • • O O O O • •
DR-LON-IP-AX LonWorks IP O O O O O O O O O O O O
DR-MBUS232-AX MODbus 232 O O O O O O O O O O O
DR-MDB-AX MODbusRTU O O O O O O O O O O O • •
DR-MDB-TCP-AX MODbusTCP O O O O O O O O O O O O
DR-FLX-AX Flex O O O O O O O O O O O
DR-OPC-CL-AX OPC O O O
DR-SNMP-AX SNMP O O O O O O O O O O O O •
Server DR-BAC-SRV-AX BACnet IP (incl client) O O O O O O O O O O O O • • • •
DR-MDB-S-AX MODbusRTU O O O O O O O O O O O
DR-MDB-TS-AX MODbusTCP O O O O O O O O O O O
Legacy DR-AAMPHP-AX AAuto PHP O O O O O O O O O O O
DR-AAMPUP-AX AAuto PUP O O O O O O O O O O O
DR-AC256-AX AC256 O O O O O O O O O O O
DR-GLOBAL-AX Global Cache O O O O O O O O O O O
DR-HELVAR-AX Helvar Lighting O O O O O O O O O O O
DR-HORTS-AX Hortsmann (EU) O O O O O O O O O O O
DR-JOSAM-AX JosamTrap Sensor O O O O O O O O O O O
DR-LANGOVN-AX Lang Oven O O O O O O O O O O O
DR-SMSALRM-AX SMSAlarm O O O O O O O O O O O
DR-VDROOT-AX VeederRoot O O O O O O O O O O O
Video DR-JAC-DED-AX 4 Cameras for DM DVR O O O O O O
DR-JAC-AXS-4 4Axis Cameras O O O O O O
Upgrade Options
WEB-U-AX Revision Upgrade O O O O O O O O O O O O O O O O
DR-SEC-LON BAS (LON) Upgrade O
DR-SEC-BAC BAS (BACnet) Upgrade O
a Resources and performance limits - no defined limit in license. ** 40 GB Hard Drive • = Standard (included) O = Optional (excluded) *NPM-128, NPM-256,NPM-1GB

314 customer.honeywell.com 70-6910


WEBs-AX System

Controls
Home
WEBs-AX™ System HVAC Controllers Options
Programmable Field Controllers
Controller Communication Programmable Open Velocity Pressure Series 60

Indoor Air Quality


Model Protocol Type Licence** UI DI AO DO Sensor (Microbridge) Floating Actuator

PUB6438S BACnet MS/TP Unitary O 6 4 3 8 NO NO

PUL6438S LonWorks Unitary O 6 4 3 8 NO NO

PVB6438NS BACnet MS/TP VAV O 6 4 3 8 YES NO

PVL6438NS LonWorks VAV O 6 4 3 8 YES NO

Combustion Controls
PVB6436AS BACnet MS/TP VAV O 6 4 3 6 YES YES

Residential
PVL6436AS LonWorks VAV O 6 4 3 6 YES YES

PUL1012S LonWorks Unitary O 1* 0 1 2 NO NO

PUL4024S LonWorks Unitary O 4* 0 2 4 NO NO

PVL4024NS LonWorks VAV O 4* 0 2 4 YES NO

Hydronic Controls
PVL0000AS LonWorks VAV O 0 0 0 0 YES YES

PVL4022AS LonWorks VAV O 4* 0 2 2 YES YES

UI - Universal Input, DI - Digital Input, AO - Analog Output,and DO - Digital Output


* One Universal Input (UI-1*) is user selectable as a fast digital pulse meter
** Spyder Individually Licensed Controller (ILC) is a fully programmable controller for any NiagaraAX Framework® platform providing the
greatest flexibility for expansion on any NiagaraAX platform.

Controls
Water
Configurable Field Controllers Inputs Outputs

Dry
Communication Wall Contact Bypass Integrated
Model Application Protocol Module Resistive Voltage Digital Button Actuator Relay Triac Analog LED

W7750A CVAHU LonWorks • 1 2 • 6 1

Building Automation
W7750B CVAHU LonWorks • 4 2 4 • 8 1

W7750C CVAHU LonWorks • 4 2 4 • 5 3 1

W7751H VAV LonWorks • 1 1 • • 4 1

W7751B/D/F VAV LonWorks • 2 1 3 • 8 1

W7752 FCU LonWorks • 1 • 3 1

Components
Commercial
W7753 Unit Ventilator LonWorks • 2 2 4 • 8 1

Remote Input/
W7761 LonWorks 4 2
Output
Pneumatic Controls

Communicating
T7350H LonWorks 8
Thermostat

Hydronic
W7762/3 LonWorks • 1 1 4
Controller
Industrial Combustion
Controls

70-6910 315
WEBs-AX System

Accessories
4XX 5XX NXS 2XX 6XX 7XX Security Compact

SEC-H-600

SEC-H-600
WEB-403-AX

WEB-403-EZ

WEB-403-AX-E

WEB-545-AX-E

WEB-5R-AX

W-NXS-FL

W-NXS-HD

WEB-201

WEB-600

WEB-602-XPR

WEB-700

SEC-H-201

SEC-H-600
Features Part Numbers Description
Display LCD-CT043A100 Reveal Color* O O O O O O O O O O O O O O O
LCD-GT043A100 Reveal Grayscale* O O O O O O O O O O O O O O O
Option Cards NPB-2X-RS485 RS 485 Card O O O O O O O O
NPB-BATTERY WEB 2 and 6 Batt O O O O O O
NPB-GPRS-H GPRS Modem O O O O O O O
NPB-GPRS-W-H GPRS Modem Kit O O O O O O O
NPB-LON LON Card O O O O O O
NPB-MDM Modem Card O O O O O O O O
NPB-PWR-H 24 V Power Module O O O
NPB-PWR-UN-H Universal Power Supply O O O O O O O
NPB-RS232 RS 232 Card O O O O O O
NPB-WPM-US Wall Adaptor (US) O O O
Input/ Output IO-16-H 16 point I/O O O
IO-16-REM-H 16 point Remote I/O O O O O O O O
IO-34-H 34 point I/O O O
SEC-H-RIO Security Remote I/O O O O O
SEC-H-R2R Security Remote Reader O O O O
* Needs a dedicated RS485 port. May need optional RS485 cards in certain cases
• = Standard (included)
O = Optional (excluded)

316 customer.honeywell.com 70-6910


WEBs-AX System
WEB-201 Controller

Controls
Home
The Honeywell WEB-201 controller is a compact, embedded
controller/server platform. Its combine integrated control,
supervision, data logging, alarming, scheduling and network
management features in a small, compact platform. The WEB-201
controller is a member of the Honeywell WEBs-AX suite of JAVA
based controller/server products.
• Runs stand-alone control, energy management, and multi-protocol

Indoor Air Quality


integration.
• Web User Interface serves rich presentation and live data to a
browser.
• Standard and optional communications boards.
• Can be expanded with optional IO-16-H and IO-34-H I/O modules.
• Small compact design is easy to install and supports multiple power
options.

Combustion Controls
Dimensions, Approximate: 6 3/8 in. wide x 4 7/64 in. high x 2.5 in. Shipping Temperature Range: 32 F to 140 F (0 C to 60 C)
deep (16.2 cm wide x 10.5 cm high x 6.4 cm deep)

Residential
Approvals:
Application: Controller Canadian Standards Association: CSA C22.2 No. 205-M1983 Signal
Application Size: Approximately 15 - 20 nodes Equipment
Building Management Interface: WEBs-AX CE: Approved
Operating System: QNX RTOS; IBM J9 JVM Java Virtual Machine; Federal Communications Commission: FCC part 15 Class A
NiagaraAX Underwriters Laboratories, Inc. UL 916, cUL listed
Operating Temperature Range: 32 F to 122 F (0 C to 50 C)
Operating Humidity Range (% RH): 5 to 95% RH, non-condensing

Hydronic Controls
Product Number Description Used With Includes
WEB-201 WEB-201 Controller WEBs-AX Platform WEB User Interface, Niagara Connectivity (Fox), oBix Client/
Server driver
WEB-201-O WEB-201 Controller with Open License WEBs-AX Platform WEB User Interface, Niagara Connectivity (Fox), oBix Client/
Server driver

WEB-600 Controller
The WEB-600 controller serves data and rich graphical displays to

Controls
Water
a standard web browser via an Ethernet LAN or remotely over the
Internet, or dial-up modem. In larger facilities, multi-building
applications and large scale control system integrations,
WEBStation-AX software can be used to aggregate information
(real-time data, history, alarms, etc.) from large numbers of
WEBsAX controllers into a single unified application. The
WEBStation-AX Supervisor can manage global control functions,

Building Automation
support data passing over multiple networks, connect to
enterprise level software applications, and host multiple,
simultaneous client workstations connected over the local
network, the Internet, or dial-up modem.
• Supports open and legacy protocols.
• Web User Interface (standard) serves rich presentation and live data
to a browser.
The WEB-600 is ideal for smaller facilities, remote sites, and for • Run stand-alone control, energy management, and multi-protocol
distributing control and monitoring throughout large facilities. integration.
Optional I/O modules can be plugged in for applications where • Standard and optional communications boards.
local control is required. The WEB-600 controller also supports a • Can be expanded with optional 16 and 34 point I/O Modules.
• Small compact design is easy to install and supports multiple power

Components
Commercial
wide range of field busses for connection to remote I/O and
standalone controllers. In small facility applications, the WEB-600 options.
controller is all you need for a complete system. • Embedded IBM® Power PC Platform.

Dimensions, Approximate: 6 3/8 in. wide x 4 7/64 in. high x 2.5 in. Approvals:
deep (16.2 cm wide x 10.5 cm high x 6.4 cm deep) Canadian Standards Association: CSA C22.2 No. 205-M1983 Signal
Application: Controller Equipment
Building Management Interface: WEBs-AX CE: Approved
Operating Temperature Range: 32 F to 122 F (0 C to 50 C) Federal Communications Commission: FCC part 15 Class A
Pneumatic Controls

Operating Humidity Range (% RH): 5 to 95% RH, non-condensing Underwriters Laboratories, Inc. UL 916, cUL listed
Shipping Temperature Range: 32 F to 140 F (0 C to 60 C)

Product Number Description Used With Includes


WEB-600 WEB-600 Controller WEBs-AX Platform WEB User Interface, Niagara Connectivity (Fox), oBix Client/
Server driver
WEB-600-O WEB-600 Controller with Open License WEBs-AX Platform WEB User Interface, Niagara Connectivity (Fox), oBix Client/
Industrial Combustion

Server driver
Controls

70-6910 317
WEBs-AX System
WEB-201/WEB-600 Accessories
Building Management Interface: WEBs-AX
Operating Humidity Range (% RH): 5 to 95% RH, non-condensing
Used With: WEB-201; WEB-600
Approvals:
Canadian Standards Association: CSA C22.2 No. 205-M1983 Signal
Equipment
CE: Approved

IO-16-H IO-34-H

NPB-PWR-H

Operating
Temperature Approvals:
Range Underwriters
Power Laboratories, Approvals:
Product Number Application Description I/O Count (F) (C) Input Includes Inc. CE
DR-LONFT10-AX Software Driver/ LONworks FTT10 Driver and NPB- — — — — — UL 916, cUL Approved
Accessory LON card bundle listed
ENC-H-001 Enclosure WEBs Small Enclosure — — — 120 Vac 24 Vac Power — —
Supply
ENC-H-002 Enclosure WEBs Large Enclosure — — — 120 Vac 24 Vac Power — —
Supply
ENC-H-BPK-1 Enclosure WEBs Small Enclosure Backplate (8 — — — — — — —
in. X 11 in.)
ENC-H-BPK-2 Enclosure WEBs Large Enclosure Backplate (11 — — — — — — —
in. X 11 in.)
IO-16-H Input/Output 16 Point Input/Output Expansion 8 UI, 32 F to 0 C to — — UL 916, cUL Approved
Expansion Module 4 DO (Relay), 122 F 50 C listed
Module 4 AO
IO-34-H Input/Output 34 Point Input/Output Expansion 16 UI, 32 F to 0 C to — Internally UL 916, cUL Approved
Expansion Module 10 DO (Relay), 8 122 F 50 C dedicated 24 Volt listed
Module AO Power Supply
NPB-GPRS-H Modem Option WEBs Cellular Modem w/o SIM Card — — — — — — —
Card
NPB-GPRS-W-H Modem Option WEBs Cellular Modem w/ Wyless — — — — — — —
Card SIM Card
NPB-MDM Optional 56kbps Modem with one RJ-11 — 32 F to 0 C to — — UL 916, cUL Approved
Communications connector for WEB-201/600 122 F 50 C listed
Card
NPB-PWR-H Power Module 24 Volt DIN mounted power module — 32 F to 0 C to — — UL 916, cUL Approved
122 F 50 C listed
NPB-WPM-US Power Adaptor Wall Power Adaptor - US Plug type — 32 F to 0 C to — — UL 916, cUL Approved
122 F 50 C listed

WEB-201/WEB-600 Drivers
Building Management Interface: WEBs

Product Number Application Description Used With


NPM-128 Software-Driver WEB-201 Memory Expansion License from 64 to 128 MB WEB-201 Platform
NPM-256MB Software-Driver WEB-600 Memory Expansion License from 128 to 256 MB WEB-600 Platform

318 customer.honeywell.com 70-6910


WEBs-AX System
WEB-403 Controller

Controls
Home
The AX Platform of controllers include smarter applications that
provide valuable information, stronger tools that empower users,
and all with a faster time-to-market with Web-services applications.
The WEB-403 AX bundles WEBs software capability in a hardware
platform that can be installed in typical building control
environments. Each WEB-403 AX connects to a system field bus
and provides real time control functions as constant streams of

Indoor Air Quality


data from individual systems are instantaneously transformed to a
common object model. The products provide a fully distributed
system when multiple units are networked together, which
provides unsurpassed scalability and reliability. In this
configuration, WEBs can be used to network controllers and
manage enterprise-level control functions. The appropriate model
is determined by connectivity and computing power requirements.
• Embedded RISC Microprocessor platform.
• 128 MB RAM/32 MB Flash

Combustion Controls
• One Lon FTT10A port for Lon device integration.
• Direct, on-board I/O with six universal inputs and 4 digital relay

Residential
outputs.
• One RS-485 port for connection to open and proprietary protocol
devices.
• One RS-232 port for integration or support of an optional internal
modem.
• Wind River VxWorks OS with Jeode Java Virtual Machine
• Niagara Control Engine

Hydronic Controls
Dimensions, Approximate: 11 in. wide x 14 in. high x 2 1/2 in. deep Approvals:
(28 cm wide x 36 cm high x 6 cm deep) Canadian Standards Association: CSA C22.2 No. 205-M1983 Signal
Application: Controller Equipment
Building Management Interface: WEBs-AX CE: Approved
Operating Temperature Range: 32 F to 122 F (0 C to 50 C) Federal Communications Commission: FCC part 15 Class A
Operating Humidity Range (% RH): 5 to 95% RH, non-condensing Underwriters Laboratories, Inc. UL 916, cUL listed
Shipping Temperature Range: 32 F to 158 F (0 C to 70 C)
Used With: WEBs-AX Platform

Product Number Description Includes

Controls
WEB-403-AX WEB 403 AX Controller LONWorks FT10 driver BACnet MSTP driver, BACnet IP Client driver, 128 MB RAM, 32 MB FlashOne

Water
10/100 MB Ethernet port - RJ-45 connection, One RJ-45 connector for RS-232 port, One RS-485 port,
One LonWorks port - FTT-10 with Weidmuller connector
WEB-403-AX-E WEB-403-AX-E Controller LonWorks FT10 driver BACnet MSTP driver, BACnet IP Client driver, 256 MB RAM, 128 MB FlashOne
with Expanded Memory 10/100 MB Ethernet port - RJ-45 connection, One RJ-45 connector for RS-232 port, One RS-485 port,
One LonWorks port - FTT-10 with Weidmuller connector
WEB-403-AX-EO WEB-403-AX-EO Controller LonWorks FT10 driver BACnet MSTP driver, BACnet IP Client driver, 256 MB RAM, 128 MB FlashOne

Building Automation
with Expanded Memory and 10/100 MB Ethernet port - RJ-45 connection, One RJ-45 connector for RS-232 port, One RS-485 port,
Open License One LonWorks port - FTT-10 with Weidmuller connector
WEB-403-AX-O WEB-403-AX-O Controller w/ LONWorks FT10 driver BACnet MSTP driver, BACnet IP Client driver, 128 MB RAM, 32 MB FlashOne
open license 10/100 MB Ethernet port - RJ-45 connection, One RJ-45 connector for RS-232 port, One RS-485 port,
One LonWorks port - FTT-10 with Weidmuller connector
WEB-403-EZ WEB 403 AX Controller Easy- LONWorks FT10 driver BACnet MSTP driver, BACnet IP Client driver, 128 MB RAM, 32 MB FlashOne
pack bundle 10/100 MB Ethernet port - RJ-45 connection, One RJ-45 connector for RS-232 port, One RS-485 port,
One LonWorks port - FTT-10 with Weidmuller connector
WEB-403-EZO WEB 403 AX Controller LONWorks FT10 driver BACnet MSTP driver, BACnet IP Client driver, 128 MB RAM, 32 MB FlashOne
Easypack bundle w/ Open 10/100 MB Ethernet port - RJ-45 connection, One RJ-45 connector for RS-232 port, One RS-485 port,

Components
Commercial
license One LonWorks port - FTT-10 with Weidmuller connector

WEB-403 Drivers
Product Number Application Description Building Management Interface Used With
WEB-403-EXPUP-AX Software-Driver Upgrade of WEB-403-AX to Unlimited WEBs WEBs-AX Platform
Pneumatic Controls
Industrial Combustion
Controls

70-6910 319
WEBs-AX System
WEB-545 Controller
The AX Platform of controllers include smarter applications that
provide valuable information, stronger tools that empower users,
and all with a faster time-to-market with Web-services applications.
Specifically designed for commercial applications, the WEB-545
AX is ideally suited for users who require a compact controller that
can be wall or enclosure mounted. A single WEB-545 AX controller
can support a network of devices via the LonWorks port and
auxiliary devices that can be accessed directly via onboard I/ O, or
through the 4 RS-485 ports, or an RS-232 port (unless used by the
optional internal modem). The WEB-545 AX can integrate any
combination of LON®, Modbus, BACnet, or legacy devices with the
appropriate optional drivers.
• Embedded RISC Microprocessor platform.
• Wind River VxWorks Operating System with Jeode Java Virtual
Machine.
• Java Application Control Engine Software with I/O control objects.
• 128 MB RAM/32 MB Flash
• One Lon FTT10A port for Lon device integration.
• Four RS-485 ports (electrically isolated) for connection to open and
proprietary protocol devices.
• Two RS-232 port for Integration or support of an optional internal
modem.
• Optional web UI services to support many simultaneous users over
the intranet or Internet via a standard web browser (WEB-545-UI
only).
Dimensions, Approximate: 11 in. wide x 14 in. high x 2 1/2 in. deep Approvals:
(28 cm wide x 36 cm high x 6 cm deep) Canadian Standards Association: CSA C22.2 No. 205-M1983 Signal
Application: Controller Equipment
Building Management Interface: WEBs-AX CE: Approved
Operating Temperature Range: 32 F to 122 F (0 C to 50 C) Federal Communications Commission: FCC part 15 Class A
Operating Humidity Range (% RH): 5 to 95% RH, non-condensing Underwriters Laboratories, Inc. UL 916, cUL listed
Shipping Temperature Range: 32 F to 158 F (0 C to 70 C)

Product Number Description Used With Includes


WEB-545-AX-E WEB-545 AX Expanded WEBs-AX Platform LONWorks FT10 driver BACnet MSTP driver, BACnet IP Client driver, 128 MB
Memory Controller with RAM, 32 MB FlashOne 10/100 MB Ethernet port - RJ-45 connection, two RJ-45
open license connectors for RS-232 port, four RS-485 ports, one LonWorks port - FTT-10
WEB-545-AX-EO WEB-545 AX Expanded WEBs-AX Platform LONWorks FT10 driver BACnet MSTP driver, BACnet IP Client driver, 128 MB
Memory Controller RAM, 32 MB FlashOne 10/100 MB Ethernet port - RJ-45 connection, two RJ-45
connectors for RS-232 port, four RS-485 ports, one LonWorks port - FTT-10

WEB-403/WEB-545 Drivers
Product Number Application Description Building Management Interface Used With
EC-SP-4XX Software-Driver WEB 403 Enterprise Connectivity Pack WEBs-AX WEB-403
EC-SP-5XX Software-Driver WEB 545 Enterprise Connectivity Pack WEBs-AX WEB-545
UI-SP-4XX Software-Driver WEB 403-AX Web User Interface WEBs-AX WEB-403
UI-SP-5XX Software-Driver WEB 545-AX Web User Interface WEBs-AX WEB-545

WEB-403/WEB-545 Accessories
Building Management
Product Number Application Description Interface Used With
MODEM-401 Accessory-Parts Modem option for WEB-403-AX and WEB-545-AX controllers WEBs WEBs-AX Platform

320 customer.honeywell.com 70-6910


WEBs-AX System
WEB-5R Controller

Controls
Home
Dimensions, Approximate: 17 in. wide X 12 in. deep X 1.75 in. high Approvals:
(431.8 mm wide X 304.8 mm wide X 44.5 mm high) Canadian Standards Association: CSA C22.2 No. 205-M1983 Signal
Application: Controller Equipment
Building Management Interface: WEBs CE: Approved
Operating Temperature Range: 32 F to 122 F (0 C to 50 C) Federal Communications Commission: FCC part 15 Class A
Operating Humidity Range (% RH): 5 to 95% RH, non-condensing Underwriters Laboratories, Inc. UL 916, C-UL listed

Indoor Air Quality


Shipping Temperature Range: 32 F to 158 F (0 C to 70 C)
Accessories:
WEB-WMT-BKT Wall Mount Brackets for WEB-5R-AX/O Controller

Product Number Description Used With Includes


WEB-5R-AX Rack Mount WEB-545-AX-E WEBs-AX One 10/100 MB Ethernet port - RJ-45 connection, two RJ-45 connectors for RS-232 port,
Controller Platform four RS-485 ports, one LonWorks port - FTT-10
WEB-5R-AX-O Rack Mount WEB-545-AX-E WEBs-AX One 10/100 MB Ethernet port - RJ-45 connection, two RJ-45 connectors for RS-232 port,

Combustion Controls
Controller with open license Platform four RS-485 ports, one LonWorks port - FTT-10

Residential
WEB-5R Accessories
Product Number Application Description Building Management Interface Used With
WEB-WMT-BKT Accessory-Parts Wall Mount Brackets for WEB-5R-AX/O Controller WEBs WEB-5R-AX

Hydronic Controls
Controls
Water
Building Automation
Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 321
WEBs-AX System
WEB-NXS Controller
Specifically designed for commercial and light industrial
applications, the WEBs NXS controllers have 512 MB RAM
standard, 1 Gb Flash drive, and a 400 MHz Celeron processor -
making it ideally suited for users who require more processing
power, or a large amount of archives or graphics.
Because it has a PC processor platform with hard disk and
embedded Microsoft® Windows XP, the NXS is ideal for
organizations whose IT policies dictate Microsoft products or when
applications such as OPC require a Windows-based operating
system. The W-NXS-AX-FL controller includes an integral UPS.
The WEBs NXS controllers have no moving parts and can be wall
or enclosure mounted. A single NXS controller can support a
network of devices via the LonWorks port and auxiliary devices
that can be accessed though the RS-485 port or the RS-232 port.
MSTP protocols are not supported on the NXS controllers.
• High performance Intel® Celeron® Microprocessor provides fast,
reliable processing
• Real-time control engine provides local closed loop control across
protocols
• Integral energy management routines
• Trending, scheduling, alarm notification via email
• Distributed architecture provides scalability and reliability
• Can be integrated with other WEBs controllers for large scale
systems
• Options for either a Flash memory-based or hard drive-based
version
Dimensions, Approximate: 6 13/16 in. wide x 7 9/16 in. high x Operating Humidity Range (% RH): 5 to 95% RH, non-condensing
10 1/16 in. deep (172 mm wide x 192 mm high x 256 mm deep) Shipping Temperature Range: 32 F to 158 F (0 C to 70 C)
Application: Controller Used With: WEBs-AX Platform
Building Management Interface: WEBs-AX Comments: Construction: Heavy-duty steel chassis
Operating System: Embedded version of Microsoft Windows™ XP, Approvals:
Microsoft Java Virtual, Java Application Control Engine with Canadian Standards Association: CSA C22.2 No. 205-M1983 Signal
NiagaraAX 3.1 or later Equipment
Voltage: 100 Vac - 240 Vac CE: Approved
Frequency: 47 to 63 Hz Federal Communications Commission: FCC part 15 Class A
Power Input: 2A Max/115V and 1A Max/230V Underwriters Laboratories, Inc. UL 916, cUL listed
Operating Temperature Range: 32 F to 122 F (0 C to 50 C)

Product Number Description Network Communications System Requirements Includes


W-NXS-AX-FL NXS controller with 1 GB flash drive and One LON FTT10 A port (78 Real-time clock with lithium 512 MB RAM, 10/100 MB Ethernet Port, (1)
NiagaraAX software version 3.1 or later, UPS KBps)One RS-485 Port, battery backup1 Gb Flash drive RS-232 Ports (1) RS-485 Port, (1)
power supply, embedded Windows XP, Web electrically isolated; One high- (W-NXS-AX-FL) or 40 Gb hard LONWorks port and driver, BACnet and
User Interface, oBIX Client/Server driver, speed RS-232 serial port; DB-9 drive (W-NXS-AX-HD and WEB- oBix drivers
Niagara Network (Fox) Client/Server driver connector; One 10/100-mbit NXS-R2)512 MB RAM; High
and LON over twisted pair. Ethernet port - RJ 45 connection Speed Intel Celeron CPU @ 650
MHz
W-NXS-AX-FLO W-NXS-AX-FL Controller with 1GB Flash
Memory and Open License
W-NXS-AX-HD NXS controller with 40 Gb hard drive and One LON FTT10 A port (78 Real-time clock with lithium 512 MB RAM, 10/100 MB Ethernet Port, (2)
NiagaraAX software version 3.1 or later, KBps)One RS-485 Port, battery backup1 Gb Flash drive RS-232 Ports, (1) RS-485 Port, (1)
embedded Windows XP, Web User Interface, electrically isolated; One high- (W-NXS-AX-FL) or 40 Gb hard LONWorks port and driver, BACnet and
oBIX Client/Server driver, Niagara Network speed RS-232 serial port; DB-9 drive (W-NXS-AX-HD and WEB- oBix drivers
(Fox) Client/Server driver and LON over connector; One 10/100-mbit NXS-R2)512 MB RAM; High
twisted pair. Ethernet port - RJ 45 connection Speed Intel Celeron CPU @ 650
MHz
W-NXS-AX-HDO W-NXS-AX-HD Controller with 40 GB Hard
Drive and Open License

WEB-NXS Accessories
Application: Power Supply Approvals:
Building Management Interface: WEBs Canadian Standards Association: CSA C22.2 No. 205-M1983 Signal
Voltage: 100 Vac - 240 Vac Equipment
Frequency: 47 to 63 Hz CE: Approved
Power Input: 2A Max/115V and 1A Max/230V Federal Communications Commission: FCC part 15 Class A
Operating Humidity Range (% RH): 5 to 95% RH, non-condensing Underwriters Laboratories, Inc. UL 916, cUL listed
Shipping Temperature Range: 32 F to 158 F (0 C to 70 C)
Used With: W-NX-AX Platform, W-NXS-R2 Platform

Product Number Description Network Communications Comments


NXS-UPS Optional UPS upgrade for W-NXS- One LON FTT10 A port (78 KBps)One RS-485 Port, electrically isolated; WEB UI Server option
AXHD or WEB-NSX-R2. Provides One high-speed RS-232 serial port; DB-9 connector; One 10/100-mbit for WEB-NXS-R2 only
UPS module with battery. Ethernet port - RJ 45 connection

322 customer.honeywell.com 70-6910


WEBs-AX System
WEBs-AX Software Controller

Controls
Home
Building Management Interface: WEBs-AX

Product Number Application Description Used With


SJ-2M-UPG-AX Software-Driver Upgrade for WEBs-AX SoftJACE. Increases Niagara point count from 10M to WEBs-AX Soft Controller
30M.

Indoor Air Quality


W-SJ-1M-AX Controller WEBs-AX SoftJACE software for Windows XP WEBs-AX Platform

WEBs-AX Platform - Displays


Reveal uses Honeywell's patent pending EZ-Nav™ technology to
provide real-time status information on an easy-to-use, wall-
mounted touch-screen LCD. Reveal has a 480 x 272, High
Definition, 24-bit Full Color backlit LCD display. It is also available

Combustion Controls
in a 16-level Extended Temperature gray-scale display. Both
displays have a viewing area of 8 in2 (51.6 cm2).

Residential
Reveal has customizable user screens, multi-language capability,
and permission-based access control. With these features it
provides site personnel the ability to quickly and conveniently
access setpoint changes, local alarm data, and other system
information.
This device can be configured through the WEBs or ComfortPoint
(CP) workbench/supervisor using a software driver.

Hydronic Controls
Reveal™ is an easy-to-operate and robust operator unit for the • Multi Language capable
entire range of WEBs-AX and ComfortPoint (CP) supervisory • Password protection
Controllers. • Upgrade of installed systems
• System-wide information access
Reveal’s touch-panel operation screens allow for easy and self- • Multiple Displays for a single Controller
explanatory operation by finger-tip. • Protocol independent
User-configurable fast-access lists can contain selected • Maintenance free
datapoints, time programs, and parameters, thus permitting plant • Network security
oriented and customer-oriented operation.
Dimensions, Approximate: 6 9/16 in. long x 3 11/16 in. wide x Shipping Temperature Range: -4 F to +140 F (-20 C to +60 C)
1 7/16 in. deep (167 mm long x 93 mm wide x 36 mm deep)

Controls
Approvals:

Water
Application: Display Canadian Standards Association: Certified
Building Management Interface: WEBs CE: CE Mark
Operating System: Windows CE Federal Communications Commission: FCC part 15 Class B
Commissioning Software: WEBs AX requirements
Voltage: 24 Vac
Operating Humidity Range (% RH): 5 to 95% RH, non-condensing

Building Automation
Operating
Temperature
Range
Network
Product Number Description Communications Output Type (F) (C) Used With
LCD-CT043A100 Reveal Color 1 RS 485 Graphical 14 F to -10 C to WEB-NXS; WEB-600; WEB-201; WEB-5R-AX;
Touchscreen Interface 122 F +50 C WEB-403; WEB-545; WEB NX Controller
LCD-GT043A100 Reveal Grayscale 1 RS 485 Graphical -4 F to -20 C to WEB-NXS; WEB-600; WEB-201; WEB-5R-AX;
Touchscreen Interface 158 F 70 C WEB-403; WEB-545; WEB NX Controller

Components
Commercial
WEBs-AX Platform - Drivers for Controllers
Application: Software-Driver
Building Management Interface: WEBs-AX
Used With: WEBs-AX Controllers

Product Number Description


Pneumatic Controls

DR-AAMPHP-AX American Automatrix PHP Driver over RS-232 or RS-485


DR-AAMPUP-AX American Automatrix PUP Driver over RS-232 or RS-485
DR-AC256-AX AC256 Driver
DR-BAC-CLI-AX BACnet IP Client Driver over Ethernet
DR-BAC-SRV-AX BACNet Server includes BACNet IP Client
DR-FLX-AX Flex Driver over RS-232 or RS-485
Industrial Combustion

DR-GLOBAL-AX Enables control of IR controlled AV equipment via an RS-323 connection to a Global Cache FC module
Controls

DR-HELVAR-AX Helvar Lighting Control Driver


DR-HORTS-AX Driver for European Hortsmann meters

70-6910 323
WEBs-AX System
Product Number Description
DR-JOSAM-AX Josam Grease Trap Sensor Driver
DR-LANGOVN-AX Lang Oven over RS-232 or RS-485
DR-LON-IP-AX LON over IP Driver
DR-LONDRIV-AX LONworks FTT10 Driver
DR-MBUS232-AX M-Bus RS-232 Driver
DR-MDB-AX Driver for Modbus RTU or ASCII over RS-485 or RS232
DR-MDB-S-AX Data server to Modbus Master devices over RS485
DR-MDB-TCP-AX Driver for Modbus TCP (25 node limit recommended)
DR-MDB-TS-AX Data server to Modbus Master devices over TCP
DR-MSTP-AX MSTP BACnet communications via RS-485 port
DR-SMSALRM-AX Enables SMS alarms to be sent to any mobile phone via a GSM/GPRS modem connected to the RS-232
DR-SNMP-AX Driver for importing data from SNMP compliant devices. Also exports WEBs alarms to SNMP devices.
DR-VDROOT-AX VeederRoot Driver
WEB-AX-EMB Embedded WEBPro-AX tool
WEB-U-AX Revision Upgrade for WEBs-AX Controller

WEBs-AX Platform - Software


Application Size: Software
Building Management Interface: WEBs-AX
Used With: WEBs-AX Platform

Product Number Description


W-ALARM-CONSL WEBs-AX Alarm Console software for Windows XP
WEB-S-AX-W AX Workbench

WEBs-AX Platform - Supervisor Software


Application Size: Software
Building Management Interface: WEBs-AX
Used With: WEBs-AX Platform

Product Number Description


WEB-S-AX WEBStation-AX Workstation software for Windows XP
WEB-S-AX-64 WEBStation-AX Workstation software for 64 bit Windows Platforms
WEB-S-AX-LNX WEBStation-AX Workstation software for Linux
WEB-S-AX-SBS Small Building System WEBStation-AX, for 3 controllers

WEBs-AX Platform - Drivers for Supervisors


Application: Software-Driver
Building Management Interface: WEBs-AX
Used With: WEBs-AX Supervisors

Product Number Description


DR-NS-BAC-500 Additional 500 point block for WEBStation-AX BACnet driver
DR-NS-BAC-AX AX Supervisor BACnet Driver
DR-NS-MDB-500 Additional 500 point block for WEBStation-AX MDB TCP Driver
DR-NS-MDB-AX AX Supervisor Modbus TCP Driver
DR-NS-OBIX-AX AX Supervisor oBix Driver
DR-NS-OBIX500 Add'l 500 point block for AX Supervisor oBix Driver
DR-NS-OPC-500 Additional 500 point block for WEBStation-AX OPC Client Driver
DR-NS-OPC-AX AX Supervisor OPC Driver
DR-NS-SNMP-500 Additional 500 point block for WEBStation-AX SNMP Driver
DR-NS-SNMP-AX AX Supervisor SNMP Driver
S-AX-BCSRV-AX AX Supervisor BACNet IP Server Driver
S-DB-CSV File Network Device Driver for importing CSV files

324 customer.honeywell.com 70-6910


WEBs-AX System

Controls
Product Number Description

Home
S-DB-DB2 WEBStation-AX driver for DB2 database
S-DB-MYSQL WEBStation-AX driver for Microsoft MySQL database
S-DB-ORCL WEBStation-AX driver for Oracle database
S-DB-SQL WEBStation-AX driver for Microsoft SQL database
SUP-U-AX Revision Upgrade for WEBStation-AX Supervisor

Indoor Air Quality


WEB-S-AX-SBS-EXUP Small Building System Upgrade
WES-PNT-AX WEBs Energy Analytics Point License. Licenses one point for monitoring on a WEBs-AX Supervisor
WES-STA-AX WEBs Energy Analytics Station License. Licenses one controller station connection to Energy Analytics with unlimited points.

WEBs-AX Platform - Accessories

Combustion Controls
Application Size: Accessory-Parts
Building Management Interface: WEBs-AX

Residential
Product Number Description Used With
H-GPRS-CBL-EXT GPRS Modem Extension Cable WEB-201; WEB-600
H-GPRS-SIM-W Wysless SIM card for GPRS Modem WEB-201; WEB-600
NPB-BATTERY Replacement Battery Assembly for WEB-201 and WEB-600 Controllers WEB-201; WEB-600

Hydronic Controls
WEBs Platform - Accessories
Building Management Interface: WEBs

Product Number Application Description Used With


50000276-014 Battery Replacement Battery For WEB 4 Series and WEB 5 Series WEB-403; WEB-545
Controller
H10026 Accessory-Parts Lon Trunk 2-position Connector Plug WEB-201; WEB-600; WEB-403; WEB-545
H10027 Accessory-Parts WEB5 RS-485 3-position Connector Plug WEB-201; WEB-600; WEB-403; WEB-545

Controls
Water
H10139 Accessory-Parts 6 Position Input/output Connector WEB-201; WEB-600; WEB-403; WEB-545
H10140 Accessory-Parts Weidmuller 3-position Straight Connector WEB-201; WEB-600; WEB-403; WEB-545
H10148 Accessory-Parts RJ-45 Adapter to DB-9 (Female Connection On both ends) WEB-201; WEB-600; WEB-403; WEB-545
H10180 Accessory-Parts 4 foot silver satin cable (male RJ-45 both ends) WEB-201; WEB-600; WEB-403; WEB-545

Building Automation
H10181 Accessory-Parts 10 Foot Silver Satin Cable (Male RJ-45 both ends) WEB-201; WEB-600; WEB-403; WEB-545
H10182 Accessory-Parts 25 Foot Silver Satin Cable WEB-201; WEB-600; WEB-403; WEB-545
H10429 Accessory-Parts 6 Position Connector for IO-16-H and WEB-IO-16 WEB-201; WEB-600; WEB-403; WEB-545
H10598 Accessory-Parts 2 Position Connector for IO-34-H and WEB IO-34 WEB-201; WEB-600; WEB-403; WEB-545
H10599 Accessory-Parts 12 Position Connector for IO-34-H and WEB-IO-34 WEB-201; WEB-600; WEB-403; WEB-545
H10600 Accessory-Parts 15 Position Connector for IO-34-H And WEB IO-34 WEB-201; WEB-600; WEB-403; WEB-545

Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 325
WEBs-AX Security System
Honeywell Security Portfolio
Flexibility is the key to Honeywell WEBs-AX™ Security, which is built on WEBs-AX Security can work as a standalone system or integrate easily
the NiagaraAX Framework®. Whether you need single site or enterprise with other WEBs-AX products as well as third-party devices for informa-
access control, intrusion detection, video surveillance or a combination tion-sharing on the enterprise level.
of all, WEBs-AX Security has the solution for you.
Figure 1. WEBs-AX Security Architecture Drawing

MANAGE REMOTELY WITH


WEB BROWSER WEBs-AX™ ENTERPRISE SECURITY

WEBsStation-AX
WEBs-AX™ ENERGY ANALYTICS
WEBs-AX™ SUPERVISOR

INTERNET/
INTRANET

ETHERNET LAN HTTP, XML, BACnet, SNMP, oBIX

FIELD INTEGRATION
SEC-H-600

ENERGY
SECURITY

VIDEO
HVAC

SEC-H-R2R
IP CAMERA

INTRUSION

ACCESS CONTROL IP CAMERA


TIME AND
ATTENDANCE
SEC-H-RIO
DVR

SECURITY ANALOG CAMERAS


ELEVATOR CONTROL
M16830

WEBs-AX Security Solution Options — WEBs-AX Integrated Video—Video drivers that provide an open video
framework designed to integrate with diverse manufacturer IP and analog
— WEBs-AX Enterprise Security—A comprehensive security and access
control system for one or more facilities and integration with existing devices and protocols.
building systems including HVAC, lighting, video, and energy analysis. — Energy Analytics—An enterprise energy monitoring application designed
Ideal for single medium to large facilities or multi-site facilities. to help manage energy in one or more facilities. Energy Analytics is a
— WEBs-AX Standalone Security—An out-of-the-box, Web-enabled software solution that provides easy to understand, easy to configure
solution for access control, intrusion detection, and video surveillance. reports that identify where, when, and how energy is used and provides
Ideal for small to medium sized facilities. cost analysis scenarios to allow the facility manager to make informed
buying decisions.
— WEBs-AX Compact Security—A cost effective solution for integrating
access control, security, video surveillance, and building automation
systems. A cost-effective solution for small to medium sized facilities.

WEBs-AX Security Solutions

Open System
Facility Doors Integration Capable Solution Selection Information
Single Facility < 32 No Standalone Security See Table 2. Security Controllers on page 6
Single Facility < 16 Yes Compact Security See Table 3. Security Controller with Compact Drivers on page 8.
Single Facility 32+ Yes Enterprise Security See Table 2. Security Controllers (page 2); Table 3. Security with
Compact Drivers (page 3) and Table 4. Enterprise Security (page 4)
Multiple Facility Unlimited Yes Enterprise Security

326 customer.honeywell.com 70-6910


WEBs-AX Security System
WEBs-AX Security Controllers Selection

Controls
Home
Features and Options SEC-H-600 SEC-H-201 More Selection Information
Controllers SEC-H-600 SEC-H-201 See Controllers, page 6
Card Readers 32* 16 See Readers and Keypads, page 10
Input/Output Points 120/120* 64/64 Third party devices such as motion sensors and
glass break detectors

Indoor Air Quality


Remote Reader Modules 15* 7 See Controller Modules and Option Cards, page 7
Remote I/O Modules 15* 8 See Controller Modules and Option Cards, page 7
Intrusion Keypads 6 2 See Intrusion Keypad/Display, (SEC-H-INT-KP), page 11
Personnel 20,000 5,000
Access Rights 250 100
Access Zones 50 10

Combustion Controls
Intrusion Zones 25 5

Residential
On-line Historical Records 50,000 10,000
Simultaneous System Users 10 5
Video Drivers DR-JAC-DED-AX Dedicated Micros N/A See Video Drivers, page 9
DVR & 4 cameras
DR-JAC-AXS-4 4 Axis IP Cameras N/A See Video Drivers, page 9
Integration Options Video (Cameras) 16 N/A

Hydronic Controls
* A total of 15 modules can be connected to the SEC-H-600 in any combination. Points and reader counts depend on mix of reader modules.

WEBs-AX Compact Security Selection

DR-SEC-LON DR-SEC-BAC
Features & Options (LON Focus) (BACnet Focus) Product Information
Controller SEC-H-600 See Controllers, page 6
Security Capabilities Card Readers 16* See Readers and Keypads, page 10
Input/Output Points 120/120* Third party devices such as motion sensors and glass

Controls
break detectors

Water
Remote Reader Modules 15* See Controller Modules & Option Cards, page 7
Remote I/O Modules 15* See Controller Modules & Option Cards, page 7
Intrusion Keypads 6 See Intrusion Keypad/Display, (SEC-H-INT-KP), page
11
Personnel 10,000

Building Automation
Access Zones 50
Intrusion Zones 25
On-line Historical Records 50,000
Simultaneous System Users 10
Video Drivers DR-JAC-DED-AX Dedicated Micros DVR & 4 cameras See Video Drivers, page 9
DR-JAC-AXS-4 4 Axis IP Cameras See Video Drivers, page 9
Open Device/Points LonWorks Devices/Points 60/2000 5/100

Components
Commercial
Supported
BACnet Devices/Points 5/100 60/2000
Modbus TCP or RTU Devices & 5/100 5/100
Points
SNMP (over Ethernet) Devices/ 5/100 5/100
Points
Integration Capabilities Video (Cameras) 16 Video Drivers, See page 9 and
third party devices
Pneumatic Controls

HVAC • Spyder®, Excel 10, & other open devices


Lighting • Third party devices
Other Open Systems • Third party devices
* A total of 15 modules can be connected to the SEC-H-600 in any combination. Points and reader counts depend on mix of reader modules.
Industrial Combustion
Controls

70-6910 327
WEBs-AX Security System
Enterprise Security Software
The WEBs-AX Enterprise Security solution is a combination of the
WEBs-AX Enterprise Security software and SEC-H-600
controller(s) and/or Compact drivers.

WEBs-AX
Station with Sec.
Software Platform Enterprise Security Security Options Tool

WEB-S-AX-SBS

WEB-S-AX
SEC-H-MYS-SBS

SEC-H-MYS

SEC-H-SQL-SBS

SEC-H-SQL

SEC-H-MT-AX
Features Part Numbers Description
Operating System a a a a b b b

Demo Available O O O

Controller LimitC 6 500 6 500 3 500 NA

Reader Limit 64 10,000 64 10,000 64 10,000


Software Drivers
Niagara Niagara Historical DB • • • • • •
Workbench • • • • • •
Security Appliance • • • • O O
HVAC Upgrade SEC-H-BAS BAS Upgrade for Security O O O O
Security Upgrade SEC-H-SUP-MYS Add Security with MYS DB O O
SEC-H-SUP-SQL Add Security with SQL DB O O
SBS Upgrade SEC-S-SBS-U Remove 64 reader, 6 Controller Limit O O
Communication oBIX Client/Server • • • • • •
Client DR-NS-OBIX-AX oBIXd O O

DR-NS-OBIX500 Additional 500 points O O


DR-NS-BAC-AX BACnet IP O O
DR-NS-BAC-500 Additional 500 points O O
DR-NS-MDB-AX MODbus TCP O O
DR-NS-MDB-500 Additional 500 points O O
DR-NS-OPC-AX OPC O O
DR-NS-OPC-500 Additional 500 points O O
DR-NS-SNMP-AX SNMP O O
DR-NS-SNMP-500 Additional 500 points O O
Server S-AX-BCSRV-AX BACnet IP O O
Video DR-SUP-DED-AX Dedicated Micro DVR O O O O O O
DR-SUP-DED-4 4 Cameras O O O O O O
DR-SUP-AXS-AX Axis Cameras O O O O O O
DR-SUP-AXS-4 4 Cameras O O O O O O
Energy Analytics WES-STA-AX Station (Controller) Connection O O
WES-PNT-AX Point (IP) Connection O O
Enterprise Security SEC-H-R-16 16 Reader Pack O O O O O O
SEC-H-R-64 64 Reader Pack O O O O O O
SEC-H-R-256 256 Reader Pack O O O O O O
SEC-H-R-1024 1024 Reader Pack O O O O O O
a Windows Server 2003, Windows XP Pro, Linux
b
Windows Server 2003, Windows XP Pro
c
Resources and performance limits - no defined limit in license.
d
oBix connectivity for controllers NOT powered by Niagara
• = Standard (included); O = Optional

328 customer.honeywell.com 70-6910


WEBs-AX Security System
WEBs-AX™ Enterprise Security Software

Controls
Home
WEBs-AX Enterprise Security is a comprehensive access control • Truly open solution-connectivity via oBIX, BACnet, SNMP, Modbus,
and security management solution, built on a truly open, IP based Lon, and other optional non-proprietary protocols
platform. Developed using the NiagaraAX Framework, WEBs-AX • Web based security application – easily managed via a standard
Enterprise Security provides unparalleled interoperability within browser anytime, anywhere
traditional security environments and extends seamlessly to • Supports database connectivity to MS SQL Server 2003 and MySQL
create a unified, intelligent building by integrating with today’s • Distributed architecture for increased reliability and control at remote

Indoor Air Quality


diverse facility systems including environmental controls, lighting, locations
energy management, and video • Centrally managed card holder and credential database
• Quick click access to video playback related to individual alarm
Enterprise Security provides scalability ranging from single door
solutions to multi-building/multi-campus deployments. Entirely events
• UL-294 and CE listed systems
accessible from any standard web browser, the solution provides
• Advanced occupancy restriction rules through access zone
flexible access into the system any time, anywhere, while
liberating end users from dedicated client workstations in the functionality
• Alarm Escalation
traditional client /server model. WEBs-AX Enterprise Security is
• Scheduled unlock on first validation
open – open architecture, open framework, open distribution, and

Combustion Controls
open protocol support. • Elevator control
• Live credential enrollment from any card reader

Residential
• Intrusion detection
• Configurable Operator Access Levels
• Simultaneous support for multiple credential formats
System Capacities

Access Access On-Line History Simultaneous Area Integrated


Personnel Card Readers Rights Schedules Zones Records System Users Controllers Cameras

Hydronic Controls
1,000,000 10,000 25,000 25,000 25,000 25,000,000 25 500 No Limit

Product Number Description


WEBs-AX Enterprise Security Server Software
SEC-H-MYS Security AX Supervisor bundled part. Includes Enterprise Security application with 32 reader license, security AX supervisor and MySQL
database driver. Supervisor limited to security Controllers and drivers only. Platform for systems greater than 64 readers. Includes OBIX
client/server driver for connecting to Niagara based controllers only.
SEC-H-MYS-SBS Security AX Small Building Supervisor bundled part. Includes Enterprise Security application with 32 reader license, security AX
supervisor and MySQL database driver.. SBS limited to max of 6 security Controller connections and 64 readers. Includes OBIX client/

Controls
server driver for connecting to Niagara based controllers only.

Water
SEC-H-SQL Security AX Supervisor bundled part. Includes Enterprise Security application with 32 reader license, security AX supervisor and SQL
database driver. Platform for systems greater than 64 readers. Includes OBIX client/server driver for connecting to Niagara based
controllers only.
SEC-H-SQL-SBS Security AX Small Building Supervisor bundled part. Includes Enterprise Security application with 32 reader license, security AX
supervisor and SQL database driver. SBS limited to max of 6 security controller connections and 64 readers. Includes OBIX client/server
driver for connecting to Niagara based controllers only.

Building Automation
WEBs-AX Enterprise Security Server Upgrades
SEC-H-SBS-U Security SBS upgrade. Removes reader limit of 64 and controller limit of 6.
SEC-H-BAS-U Upgrade security supervisor to allow BAS driver functionality.
SEC-H-SUP-MYS Base Enterprise security software, includes reader license for 32 readers, Enterprise security application and MySQL database driver.
Part required for all instances of Security 2.0. Requires AX supervisor software or small building AX supervisor software.
SEC-H-SUP-SQL Base Enterprise security software, includes reader license for 32 readers, enterprise security application and SQL database driver. Part
required for all instances of Security 2.0. Requires AX supervisor software or small building AX supervisor software.
WEBs-AX Enterprise Security Reader Expansion Packs

Components
Commercial
SEC-H-R-16 Expands enterprise security license by 16 readers.
SEC-H-R-64 Expands enterprise security license by 64 readers.
SEC-H-R-256 Expands enterprise security license by 256 readers.
SEC-H-R-1024 Expands enterprise security license by 1024 readers. Pneumatic Controls
Industrial Combustion
Controls

70-6910 329
WEBs-AX Security System
WEBs-AX™ Security Controllers
• Integrated management of access control, alarm monitoring, and
credential database
• Pre-defined custom reports on-screen or exported
• Web-based security application - easily managed via a web browser
anytime, anywhere
• Web User Interface serves rich presentations and live data to a
browser
• No thick client software required
• Custom graphic floor plans and equipment displays
• User-definable Wiegand card formats
• Robust, modular solution for smaller facilities
• Seamlessly integrates to Video Monitoring, HVAC, Lighting, and
Energy Management in the WEBs-AX Automation System or other
open systems
The WEBs-AX Security Controller provides an out of the box, web- • Connectivity to any BAS system via BACnet®, LONWORKS®,
enabled solution for access control and intrusion detection with Modbus®, and oBIX
integrated reporting and alarm management. Users can assign • IT connectivity includes XML, oBIX, SNMP
access rights, schedules, credentials, and perform system set up • Built on the NiagaraAX Framework - the industry’s leading facility
and maintenance via a web browser from anywhere in the world. management software platform
The easy to use security control application and user interface are • On-board I/O for 2 standard Access Controlled doors, 2 Alarm
embedded in the WEBs-AX Security Controller requiring no Inputs, and 2 Relay outputs
additional software to set up or operate the system. The embedded • SEC-H-201: Expandable to 16 readers and 64 input and 64 output
application can provide complete access control and intrusion points. Up to10,000 personnel credentials.
detection functionality in a stand alone mode or it can be easily • SEC-H-600: Expandable to 32 readers and up to 120 input and 120
integrated into the WEBs-AX automation system to control output points depending on mix of up to 15 remote modules. Video
lighting, HVAC equipment, and other building management integration with up to 16 cameras. Up to 20,000 personnel
strategies in response to access events and system alarms. WEBs- credentials. Integrates directly with Lon or BACnet remote devices
AX Security Controllers may also be joined to an Enterprise using Compact Security Drivers (see controller drivers section for
Security server to provide central database management for larger details).
applications requiring more than one controller.

System Capacity SEC-H-600 SEC-H-201


Personnel 20,000 5,000
SEC-H-R2R Modules (2 Wiegand Readers, 4 supervised digital inputs, 2 relay outputs, 2 digital inputs) 151 7

SEC-H-RIO Modules (8 digital outputs, 8 supervised digital inputs, 2 digital inputs) 151 8

IO-REM-16-H (8 universal inputs, 4 relay outputs, 4 analog outputs) 151 N/A

Access Rights 250 100


Schedules 100 25
Access Zones 50 10
Intrusion Zones 25 5
Intrusion Keypads 6 2
On-line Historical Records 50,000 10,000
Simultaneous System Users* 10 5
Video (Cameras) 16 N/A
1. SEC-H-600 controller may connect to 15 SEC-H-R2R or SEC-H-RIO or IO-REM-16-H modules total in any combination.

330 customer.honeywell.com 70-6910


WEBs-AX Security System
Controller Modules and Option Cards

Controls
Home
WEBs-AX™ Security Modules
Expand the capacity of your WEBs-AX Security Controller with the
SEC-H-RIO, remote input/output module, and the SEC-H-R2R
remote reader modules.

Indoor Air Quality


Wiegand Card Reader
Product Number Interface Supervised Digital Inputs Relay Outputs Digital Inputs
SEC-H-RIO - 8 8 2

SEC-H-R2R 2 4 2 2

Combustion Controls
WEBs-AX™ IO Modules

Residential
Monitor and control building automation points with the
IO-16-REM-H. These modules may not be connected to the
SEC-H-201 controller.

Product Number Universal Inputs Analog Outputs Relay Outputs


IO-16-REM-H 8 4 4

Hydronic Controls
WEBs-AX™ Option Cards

Controls
Water
Use these option cards to interface to other open systems on the
SEC-H-600 when using the Compact Security Drivers. The NPB-2X-
RS485 option card is required on the SEC-H-201 and SEC-H-600
controllers to interface with the Intrusion Keypad.

Product Number Description

Building Automation
NPB-LON 78 Kbps FTT 10 A LON Adapter. Uses one of the two communication slots in the SEC-H-600
NPB-2X-RS485 Dual Port RS485 Option Card. Uses one of the two communication slots in the SEC-H-201 or SEC-H-600.
NPB-RS232 Single Port RS232 Option Card. Uses one of the two communication slots in the SEC-H-600.

Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 331
WEBs-AX Security System
Compact Security Solution Drivers
WEBs Compact Security Solution provides a cost effective
solution for integrating access control, security, video
surveillance, and building automation on the SEC-H-600 platform.
A Lon or BACnet Focused Driver Option Pack determines the mix
of controlled devices that can be integrated onto the platform. The
embedded WEBs-AX security control application allows thin-client
configuration of the access control and security functions. WEBs-
AX Workbench software is required for configuration of the HVAC
devices. Note that card reader and personnel record capacities are
reduced when using the Compact Security Drivers. Option cards to
interface with BACnet, Lon, Modbus, and SNMP are ordered
separately

Compact Security Solution System Capacities

DR-SEC-LON DR-SEC-BAC
LON Devices/Points (TP/FT-10) 60 Devices/2000 Points 5 Devices/100 Points
BACnet Devices/Points (IP or MSTP) 5 Devices/100 Points 60 Devices/2000 Points
Modbus TCP or RTU 5 Devices/100 Points 5 Devices/100 Points
SNMP (over Ethernet) 5 Devices/100 Points 5 Devices/100 Points
Remote I/O modules (SEC-H-RIO) 151 151
Remote Reader Modules (SEC-H-R2R) 151 151
Digital Input/Output Points 120 inputs/ 120 outputs2 120 inputs/ 120 outputs2
Card Readers 162 162
Intrusion Keypads (SEC-H-INT-KP) 4 4
Personnel Records 10,000 10,000
History Records 50,000 50,000
1. Maximum of 15 modules (SEC-H-RIO and SEC-H-R2R) per SEC-H-600.
2. Up to 16 readers or 120 I/O points, depending on module combination.

332 customer.honeywell.com 70-6910


WEBs-AX Security System
Video Integration Drivers

Controls
Home
WEBs-AX Integrated Video is an open video framework solution • Create video system alarm record and associate recorded video for
designed to integrate diverse manufacturer devices and protocols instant look-up
into a unified, smart facility management system. Built on the • Initiate control logic sequences such as lighting control, building
NiagaraAX Framework®, WEBs-AX Video integrates with IP and lockdown, etc.
analog based systems to create complete interoperability between • Ability to view live video through NiagaraAX graphical user
video, security, lighting, energy management, and building experience.

Indoor Air Quality


automation for any facility. • Supports pan, tilt, zoom, iris, and focus camera control.
• Bi-directional alarming interface between NiagaraAX stations and • Query video subsystem for stored video and playback by time and
video products. date.
• NiagaraAX alarms can initiate events in video subsystem. • Integrated video playback with Niagara alarm console.
• Video system events such as video motion detection and camera • Customizable user experience through extensive video widget
loss alarms can be processed as standard Niagara alarms. library (PX pages).
• Automatically redirect camera and start video recording based on
events or alarms

WEBs-AX™ Platforms Supported for Video Integration Drivers (Requires NiagaraAX Build 3.4 or later)

Combustion Controls
Residential
Product Number Product Restrictions
SEC-H-MYS Enterprise Security Server with MYS database No Set Limit
SEC-H-MYS-SBS Enterprise Security Server Small Building System with MYS Database No Set Limit
SEC-H-SQL Enterprise Security Server with SQL database No Set Limit
SEC-H-SQL-SBS Enterprise Security Server Small Building System with MYS Database No Set Limit

Hydronic Controls
W-S-AX WEBs-AX Supervisor No Set Limit
W-SJ-1M-AX WEBs SoftJACE No Set Limit
SEC-H-600 WEBs Expanded Security Controller Maximum of 16 cameras
WEB-600, WEB-600-O WEB 600 Controller Maximum of 16 cameras, requires NPM-256 memory
option.

Part# Description
DR-SUP-DED-AX Base Driver for Dedicated Micros DVR for WEBs Supervisor, WEBs SoftJACE, or Enterprise Security. Includes support for up to 16
cameras.

Controls
Water
DR-SUP-DED-4 Additional 4 camera license for Dedicated Micros DVR on WEBs Supervisor, WEBs SoftJACE, or Enterprise Security.
DR-JAC-DED-AX Driver for Dedicated Micros DVR and 4 cameras on SEC-H-600 or WEB-600.
DR-SUP-AXS-AX* Base Driver for Axis IP Cameras for WEBs Supervisor, WEBs SoftJACE, or Enterprise Security. Supports for up to 16 cameras.
DR-SUP-AXS-4* Additional 4 camera license for Axis IP cameras on WEBs Supervisor, WEBs SoftJACE, or Enterprise Security.
DR-JAC-AXS-4* Driver for 4 Axis IP Cameras on SEC-H-600 or WEB-600.

Building Automation
*Note: Axis IP Camera drivers do not support video playback, they are used for live viewing only. To integrate recording of IP cameras, use a sup-
ported DVR with IP interface.

Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 333
WEBs-AX Security System
Readers and Keypads
OmniProx™ Proximity Card Readers All OmniProx™ readers (except the OP90) include three bezels:
black, charcoal gray and ivory and are constructed with rugged
Honeywell’s OmniProx™ family is a complete line of 125 kHz HID polycarbonate materials potted for both indoor and outdoor
compatible proximity readers that delivers outstanding and applications.
consistent performance in a small package with attractive styling
and colors to fit any décor. For locations that require a proximity reader able to withstand the
vandal-prone environments, such as: universities, schools,
elevators and prisons, the OP90 vandal resistant reader comes
standard in a zinc die-cast metal housing.

Read Range Read Range Max. Operating Current Operating


Product Number (PVC Card) (Key Fob) Dimensions @ 5 VDC Voltage
OP10HONE 2.25” 1.25” 3.15” H x 1.57” W 50 mA 5.0 -16 VDC

OP30HONE 2.25” 1.25” 5.71” H x 1.69” W 100 mA 5.0 -16 VDC

OP40HONE 2.25” 1.25” 4.33” H x 2.95” W 100 mA 5.0 -16 VDC

OP90HONE 1.25” Not recommended 4.5” H x 3.15” W 100 mA 5.0 -16 VDC

Readers with PIN Keypads


OmniClass™ Reader/Keypad ProxPro® Reader/Keypad
OmniClass™ OM56BHONA reader/keypad is The ProxPro® Hu5355AGK00 proximity
built upon the convenience and reliability of card reader’s weatherproof design and
prox technology and reads both 125 kHz architecturally attractive enclosure allows
Prox and 13.56 MHz Smart cards. Keypad is easy mounting indoors or out. Reads
backlit for easy visibility in low-light 125kHz Prox cards. The ProxPro Reader is
conditions. LED bar at top of reader makes ideal for applications requiring a larger read
ADA compliant with built-in audible beeper. range. LED and beeper indicate access
card reads.

Product Number Max Read Range Dimensions Max. Operating Current @ 12 VDC Operating Voltage
OM56BHONA 4” 4.8” H x 3.3” W 253 mA 10 -16 VDC
HU5355AGK00 7” 5.0” H x 5.0 “ W 120 mA 10-28.5 VDC

334 customer.honeywell.com 70-6910


WEBs-AX Security System
Intrusion Keypad/Display

Controls
Home
Smartkey Intrusion Keypad and Display. The SEC-H-INT-KP Smartkey Intrusion Keypad and Display is used
for arming and disarming areas protected by intrusion monitoring
such as motion detection, glass break detection, door and window
status switches and other monitoring devices.
Multiple users and zones may be controlled with a single keypad
by assigning unique PIN numbers to system operators. The

Indoor Air Quality


display warns the user if a zone is in alarm prior to arming to avoid
unwanted alarms.
Requires an NPB-2X-RS485 Option card to interface with SEC-H-
600 and SEC-H-201 Security Controllers.

Combustion Controls
Product Number Max per SEC-H-600 Max per SEC-H-201 Dimensions Max. Operating Current @ 12 VDC Operating Voltage

Residential
SEC-H-INT-KP 6 2 5.12” H x 3.23” W 150 mA 12 -15 VDC

Credentials
125 kHz HID compatible Proximity Credentials

Product Number Description


PVC-H-4 HID PVC Prox Card (34-Bit). HID PVC proximity card sequentially numbered where encoded number equals

Hydronic Controls
printed number. Allows a video photo ID to be printed directly on the card surface. This card can be used with all
PVC printers. Dimensions: 2.125 IN. H x 3.375 IN. W (5.398cm H x 8.573cm W) Minimum order quantity of 25.
Must be ordered in increments of 25.
PX-4-H HID proximity card (34-bit) with Honeywell logo and a slot hole punch on the short side. Dimensions: 2.125 IN. H x
3.375 IN. W x 0. 070 IN. T (5.398cm H x 8.573cm W x .178cm T). Minimum order quantity of 25. Must be ordered
in increments of 25.

PX-KEY-H HID Proximity Card Key Fob (34-Bit). HID proximity key fob (34-bit) designed to be carried on a user’s key ring.
Read ranges may be reduced by 50% when using the fob versus a card. Dimensions: 1.87 IN. H x .925 IN. W x

Controls
.395 IN. T (4.75 cm H x 2.350 cm W x 1 cm ). Minimum order quantity of 10. Must be ordered in multiples of 10.

Water
Building Automation
Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 335
WEBs-AX Security System
Request to Exit Devices
PIR Overhead Motion Sensors Push Button
Mount IS310BL and IS310WH PIR (passive infra-red) motion The EXB-1 is used to signal the access control panel to unlock a
sensors over access controlled doors to inhibit alarms when door and inhibit door alarms when exiting.
exiting and/or to unlock the door. Hands-free automatic operation
makes these units the ideal request to exit devices for access
control systems.

Product Number Description


IS310BL Request-to-Exit Sensor, Standard Version - Black. Adjustable relay time (0.5 - 64 seconds), Adjustable
“tamper proof” shutters, to enable precise target area detection, Two “Form C” outputs, Swivel optics –
allow for offset mounting.

IS310WH Request-to-Exit Sensor, Standard Version - White. Adjustable relay time (0.5 - 64 seconds), Adjustable
“tamper proof” shutters, to enable precise target area detection, Two “Form C” outputs, Swivel optics –
allow for offset mounting.

EXB-1 Egress Button. Exit button with a single gang stainless steel mounting plate, DPDT. Can be configured
with momentary or latching contact status. Temperature range: 32° to 158° F (0° to 70° C). Dimensions:
4.5 IN. H x 2.75 IN. W x 2.13 IN. D (11.43cm H x 6.99cm W x 5.40cm D).

Door Locks
The NS5100 Electric Strike and ML8011-LC-US28 locks work with
many types of doors and applications.

Product Number Description


ML8011-LC-US28 UL listed magnetic door lock for a single door with 1,200lbs (544kg) holding force. Operates on 12/24VDC.2A
current draw and comes with a US28 (satin stainless) finish. Lock dimensions: 2.625 IN. H x 10.5 IN. W x
1.625 IN. D (6.67cm H x 26.67cm W x 4.13cm D). Armature dimensions: 2.5 IN. H x 7 IN. W x .375 IN. D
(6.35cm H x 17.78cm W x .95cm D).

NS5100 1300lb Electric Strike, non-handed. Fail-secure/fail-safe field reversible. Maximum current draw is .38A @
12VDC or .19A @ 24VDC. Strike includes three face plates for use with hollow metal, wood, or aluminum
frames. Adjustable keeper and small back box fit almost any application. Retrofit existing doors or lock
replacements with included neoprene filler. Back box: 3.375 IN. H x 1 IN. W x 1.345 IN. D. Keeper pocket:
1.4375 IN. H x .5 IN. D x .6875 IN. –.8125 IN. W (adjustable).

336 customer.honeywell.com 70-6910


WEBs-AX Security System
Enclosures and Power Supplies

Controls
Home
WEBs-AX™ Security Enclosures
Custom enclosures are available for secure mounting of the
WEBs-AX Security controller and the Remote Reader and Input/
Output modules. Three sizes are available to allow for various
combinations of controllers and remote modules and all are
equipped with a key lock and tamper switch. The medium and large

Indoor Air Quality


enclosures may be ordered with a factory mounted universal
voltage power supply (NPB-PWR-UN-H) covered by a protective
metal shield. Knockouts are provided on top, bottom and sides for
external connections. The enclosure interiors have a generous
amount of space for cable management. These enclosures are
required to maintain the UL access control and FCC listing. The
Security controller MUST be mounted in a WEBs-AX Security
enclosure with integral supply to properly charge the on-board
NiMH batteries and maintain the controller listings.

Combustion Controls
Residential
Product Number Description
SEC-ENC-H-1 Security panel medium enclosure with integral NPB-PWR-UN-H universal power supply. 17” W x 15” H x 4” D with DIN rail, tamper
switch, key lock, and capacity for 2 user provided SLA backup batteries. Can enclose one Security Controller, or 2 reader modules or
one Remote I/O module.
SEC-ENC-H-1NP Security panel medium enclosure. 17” W x 15” H x 4” D with DIN rail, tamper switch, key lock, and capacity for 2 user provided SLA
backup batteries. Can enclose 2 reader modules or one Remote I/O module plus one additional reader module in place of the integral
power supply not included with this part.

Hydronic Controls
SEC-ENC-H-2 Security panel large enclosure with integral NPB-PWR-UN-H universal power supply. 17” W x 22” H x 4” D with DIN rails, tamper switch,
key lock, and capacity for 2 user provided SLA backup batteries. Can enclose one Security Controller and up to four Reader Modules, or
two I/O modules, or two Reader Modules and one I/O Module.
SEC-ENC-H-2NP Security panel large enclosure. 17” W x 22” H x 4” D with DIN rails, tamper switch, key lock, and capacity for 2 user provided SLA
backup batteries. Can enclose up to seven Reader modules or three I/O modules plus one additional Reader module in place of the
integral power supply not included with this part. Other combinations of Reader and I/O modules are possible.
SEC-ENC-H-3 WEBs-AX Security Small enclosure 6 in. W x 9 in. H x 4 in. D with DIN rail, tamper switch and key lock. Encloses one Reader module.
NPB-PWR-UN-H 90 - 263 V AC 50/60 Hz Auto sensing Power Supply Module, DIN Rail Mountable 15 VDC Output.

Auxiliary Power Supplies by Honeywell Power Products

Controls
These access control power supplies/chargers will convert

Water
115VAC/60Hz into power limited field-selectable continuous power
output. These power supplies are UL listed for access control
(UL294), fire alarm (UL1481) and burglar alarm installations
(UL603), and conform to NEC requirements. LED diagnostics
speed troubleshooting and fused disconnects make servicing
easier. Relay outputs provided for remote monitoring of AC Power
fail and Battery fail. All supplies are field configurable for 12 or 24

Building Automation
VDC output. Dimensions: 13 in. H x 13.5 in. W x 3.25 in. D (33 cm H
x 34.3 cm W x 8.3 cm D).

Product Number Output Current Protected Outputs


HP300ULX 2.5 A 1

Components
Commercial
HP300ULPD4CB 2.5 A 4
HP400ULX 4.0 A 1
HP400ULPD4CB 4.0 4
HP600ULX 6.0 1
HP600ULPD16CB 6.0 16

Backup Battery
Pneumatic Controls

Sealed Lead-Acid 7 AH backup battery. Use these batteries to


provide backup power for the WEBs-AX Security controller and
auxiliary power supplies
Industrial Combustion

Product Number Description


712BNP 12V 7AH Battery
Controls

70-6910 337
WEBs R2 System
WEB 403 R2 Controller
The WC2003B WEB-403 bundles WEBs software capability in a
hardware platform that can be installed in typical building control
environments. Each WEB-403 connects to a system field bus and
provides real-time control functions as constant streams of data
from individual systems are instantaneously transformed to a
common object model. The products provide a fully distributed
system when multiple units are networked together, which
provides unsurpassed scalability and reliability. In this
configuration, WEBs can be used to network controllers and
manage enterprise-level control functions. The appropriate model
is determined by connectivity and computing power requirements.
• Embedded RISC Microprocessor platform.
• One LON® FTT10A port for LON® device integration.
• Direct, on-board I/O with six universal inputs, and 4 digital relay
outputs.
• One RS-485 port for connection to open and proprietary protocol
devices.
• One RS-232 port for Integration or support of an optional internal
modem.
• Integral Web User Interface services to support many simultaneous
users over the intranet or Internet via a standard web browser.
• The WC2003B1022 can integrate up to 27 LONWORKS® devices.
• The WC2003B1048 can integrate up to 120 LONWORKS® devices.
Dimensions, Approximate: 11 in. wide x 14 in. high x 2 1/2 in. deep Shipping Temperature Range: 32 F to 158 F (0 C to 70 C)
(28 cm wide x 36 cm high x 6 cm deep)
Approvals:
Application: Controller Canadian Standards Association: CSA C22.2 No. 205-M1983 Signal
Building Management Interface: WEBs Equipment
Voltage: 25 VA max CE: Approved
Frequency: 50 Hz; 60 Hz Federal Communications Commission: FCC part 15 Class A
Power Consumption: 120 Vac Underwriters Laboratories, Inc. UL 916, cUL listed
Operating Temperature Range: 32 F to 122 F (0 C to 50 C)
Operating Humidity Range (% RH): 5 to 95% RH, non-condensing

Product Number I/O Count Used With Comments Includes


WC2003B1022 4 DO relays with LED WEBs System Includes Web User Interface, One 10/100 MB Ethernet port - RJ-45 connection, One
indicators, 6 UI license restricted to 27 node RJ-45 connector for RS-232 port, One RS-485 port, One
max. LonWorks port - FTT-10 with Weidmuller connector
WC2003B1048 4 DO relays with LED WEBs System Includes Web User Interface, 120 One 10/100 MB Ethernet port - RJ-45 connection, One
indicators, 6 UI connected device (node) limit RJ-45 connector for RS-232 port, One RS-485 port, One
LonWorks port - FTT-10 with Weidmuller connector

WEB 403 R2 Drivers


Building Management Interface: WEBs

Product Number Application Description Used With


WC2003B1055 Controller Option to upgrade existing WEB-403 to provide unrestricted connected device limit. WEBs System

338 customer.honeywell.com 70-6910


WEBs R2 System
WEB 545 R2 Controller

Controls
Home
Honeywell WEBs® is a product suite developed on the Niagara
Framework® that provides an end-to-end building automation
solution. Users can seamlessly integrate LONWORKS®, BACnet®,
Modbus®, OPC, and other standard protocols with legacy systems
to provide a unified real-time controls network. The suite includes
a browser-based graphical user interface allowing users to view
and manipulate underlying systems without the need for dedicated

Indoor Air Quality


workstations or client software.
• Embedded RISC Microprocessor platform.
• One LON® FTT10A port for LON® device integration.
• Four RS-485 ports (electrically isolated) for connection to open and
proprietary protocol devices.
• Two RS-232 port for Integration or support of an optional internal
modem.

Combustion Controls
Residential
Dimensions, Approximate: 11 in. wide x 14 in. high x 2 1/2 in. deep Shipping Temperature Range: 32 F to 158 F (0 C to 70 C)
(28 cm wide x 36 cm high x 6 cm deep) Approvals:
Application: Controller Canadian Standards Association: CSA C22.2 No. 205-M1983 Signal
Building Management Interface: WEBs Equipment
Voltage: 25 VA max CE: Approved
Frequency: 50 Hz; 60 Hz Federal Communications Commission: FCC part 15 Class A
Power Consumption: 120 Vac

Hydronic Controls
Underwriters Laboratories, Inc. UL 916, C-UL listed
Operating Temperature Range: 32 F to 122 F (0 C to 50 C)
Operating Humidity Range (% RH): 5 to 95% RH, non-condensing

Product Number Used With Comments Includes


WC2003A2005 WEBs System — One 10/100 MB Ethernet port - RJ-45 connection, two RJ-45 connectors for RS-232 port, four RS-
485 ports, one LonWorks port - FTT-10
WC2003B2004 WEBs System Includes Web User One 10/100 MB Ethernet port - RJ-45 connection, two RJ-45 connectors for RS-232 port, four RS-
Interface software 485 ports, one LonWorks port - FTT-10

Controls
Water
WEB 545 R2 Drivers
Building Management Interface: WEBs

Product Number Application Description Used With


WEB-5-UP-UI Software-Driver WEB User Interface for WEB-545 Controller WEB-545

Building Automation
WEB-NXS R2 Controller
Dimensions, Approximate: 6 13/16 in. wide x 7 9/16 in. high x Shipping Temperature Range: 32 F to 158 F (0 C to 70 C)
10 1/16 in. deep (172 mm wide x 192 mm high x 256 mm deep) Comments: Construction: Heavy-duty steel chassis
Application: Controller Used With: WEBs R2 Platform
Building Management Interface: WEBs R2
Approvals:
Operating System: Embedded version of Microsoft Windows™ XP, Canadian Standards Association: CSA C22.2 No. 205-M1983 Signal
Sun Hotspot VM, Java Application Control Engine with Niagara R2 Equipment
Voltage: 100 Vac - 240 Vac

Components
CE: Approved

Commercial
Frequency: 47 to 63 Hz Federal Communications Commission: FCC part 15 Class A
Power Input: 2A Max/115V and 1A Max/230V Underwriters Laboratories, Inc. UL 916, cUL listed
Operating Temperature Range: 32 F to 104 F (0 C to 40 C)
Operating Humidity Range (% RH): 5 to 95% RH, non-condensing

Product Number Description Network Communications System Requirements Includes


WEB-NXS-R2 NXS controller with 40 Gb One LON FTT10 A port (78 Real-time clock with lithium battery 512 MB RAM, 10/100 MB
Pneumatic Controls

hard drive and Niagara KBps)One RS-485 Port, electrically backup1 Gb Flash drive (W-NXS- Ethernet Port, (1) RS-232
Release 2 (R2) software, isolated; One high-speed RS-232 AX-FL) or 40 Gb hard drive (W- Ports (1) RS-485 Port, (1)
embedded Windows SP and serial port; DB-9 connector; One NXS-AX-HD and WEB-NXS- LONWorks port and driver,
LON over twisted pair. 10/100-mbit Ethernet port - RJ 45 R2)512 MB RAM; High Speed Intel BACnet and oBix drivers, 40
connection Celeron CPU @ 650 MHz GB Hard Drive
Industrial Combustion
Controls

70-6910 339
WEBs R2 System
WEBs R2 Platform - Drivers for Controllers
Application : Software-Driver
Building Management Interface: WEBs R2

Product Number Description Used With


32005192-004 DDE Driver for WEB controller WEBs R2 Platform
32005192-006 Driver for Modbus TCP WEBs R2 Platform
32005192-007 Driver for Modbus Server (WEB NP only). WEBs R2 Platform
32005192-016 Driver for MSTP BACnet communications via RS-485 port - supports max of 31 BACnet MSTP WEBs R2 Platform
devices. Note: 27 max. device limit on WEB 403.
DRV-A256 Driver for Andover AC-8 and AC-256 WEBs R2 Platform
DRV-AINF Driver for Andover Infinity WEBs R2 Platform
DRV-APUP Driver for American Automatrix WEBs R2 Platform
DRV-CSD Configurable Serial Driver WEBs R2 Platform
DRV-MCQ Driver for McQuay Open Protocol WEBs R2 Platform
DRV-NOVUS Driver for Novus Door Access System WEBs R2 Platform
DRV-NOVUS-DOOR Support for each additional Novus Door WEBs R2 Platform
DRV-SNMP SNMP device driver WEBs R2 Platform
DRV-SOL Driver for Solidyne building controller WEBs R2 Platform
DRV-TCS Driver for TCS-Basys WEBs R2 Platform
DRV-TLC Driver for GE TLC Lighting Panel WEBs R2 Platform
WEB-U Revision Upgrade for WEBs-R2 Controller WEBs R2 Platform
ZW2002A1009 Modbus Driver for WEB controller WEBs R2 Platform

WEBs R2 Platform - Software


Application: Software
Building Management Interface: WEBs R2

Product Number Description


ZW2001A1001 Additional copies of WEBPro Software - per copy

WEBs R2 Platform - Supervisor Software


Building Management Interface: WEBs R2

Product Number Application Description


ZW2000A1003 Software WEBStation Software WS-1 and first copy of WEBPro Software: for a single JACE
ZW2000B1002 Software-Driver WEBStation Software; additional node
ZW2000C1001 Software WEBStation Software and 20 pack of node software keys.
ZW2000D1000 Software WEBStation Software and 50 pack of node software keys.
ZW2000E1009 Software WEBStation Software and 100 pack of node software keys.
ZW2000F1008 Software Master WEBStation Software for monitoring multiple WEB Supervisors.
ZW2000G1007 Software-Driver N additional Mast WEBStation Software licenses
ZW2003A1007 Software-Driver BACnet Supervisor, 500 additional point license block.
ZW2003A1023 Software BACnet Supervisor base software. Includes license for 500 BACnet points.

WEBs R2 Platform - Drivers for Supervisors


Application : Software-Driver
Building Management Interface: WEBs R2

Product Number Description Used With


32005192-011 Service to monitor and manage alarms from multiple Niagara Systems through a single client interface. WEBs R2 Platform
32005192-012 License for an additional client for the WEBs R2 Alarm Service. WEBs R2 Platform
32005192-015 Proteus Alarm Service for Eagle Maintenance Management Software. Runs on any WEBs R2 Supervisor. WEBs R2 Platform
32005192-017 SQL Driver for Web Supervisor, OPC Supervisor or BACnet Supervisor. Does not include MS SQL Server WEBs R2 Platform
Software.
32005192-021 Tenant Billing Service. Runs on any Web Supervisor. WEBs R2 Platform
WS-MSDE MSDE Driver for WEBStation, OPC Supervisor or BACnet Supervisor WEBs R2 Platform

340 customer.honeywell.com 70-6910


WEBs R2 System

Controls
Product Number Description Used With

Home
WS-MTCP-500 Modbus 500 Point Addition WEBs R2 Platform
WS-OPC-500 OPC 500 Point Addition WEBs R2 Platform
WS-ORCL Oracle Driver WEBs R2 Platform
WS-OSD Open System Driver WEBs R2 Platform
WS-SNMP-500 SNMP 500 Point Addition WEBs R2 Platform

Indoor Air Quality


ZW2003A1015 BACnet Supervisor node license. Enables a WEB to be connected to a BACnet Supervisor. One required —
per WEB.

Combustion Controls
Residential
Hydronic Controls
Controls
Water
Building Automation
Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 341
Spyder Controllers
Spyder Programmable Controllers
The Spyder Family of controllers are for use in VAV (Variable Air
Volume) and Unitary HVAC control applications. Each controller
communicates via either LONWORKS® or BACnet MS/TP network
communications. Each controller provides flexible, universal
inputs (UI) for external sensors, digital inputs (DI), and a
combination of analog outputs (AO) and digital Triac outputs (DO).
The Sylk Bus is included in each controller which enables
connection to other Sylk enabled devices. These controllers
provide many options and advanced system features that allow
state-of-the-art commercial building control. Each controller is
programmable and configurable using the NIAGARA AX
FRAMEWORK® software.

Dimensions, Approximate: 5.45 in. high x 6.85 in. wide x 2.26 in. deep Approvals:
(138.4 mm high x 174 mm wide x 57.4 mm deep) Canadian Standards Association: Certified
Application Size: Small to Large CE: Approved
Commissioning Software: WEBs AX Federal Communications Commission: FCC Part 15, Subpart B,
Voltage: 24 Vac with a valid range of 20 to 30 Vac Class B
Frequency: 50 Hz; 60 Hz Underwriters Laboratories, Inc. UL 916
Operating Humidity Range (% RH): 5 to 95% RH, non-condensing
Setpoint Temperature Range: Programmable
Accessories:
TR70 Zio LCD Wall Module (Temperature)
Shipping Temperature Range: -40 F to 150 F (-40 C to 65.5 C)
TR70-H Zio LCD Wall Module (Temperature & Humidity)
Compatible with: WEBs AX
Comments: Onboard 20 VDC power supply

Operating
Temperature
Power Range
Network Com- Con-
Product Number Description munications I/O Count sumption Output Type (F) (C) Includes
PUB6438S Spyder Programmable BACnet MS/TP 6 UI, 4 DI, 5 VA Pulse Width Modulation, -40 F to -40 C to —
Unitary Controller 3 AO, 8 DO Floating, Staged On/Off 150 F 65.5 C
PUB6438S-ILC Spyder ILC Programmable BACnet MS/TP 6 UI, 4 DI, 5 VA Pulse Width Modulation, -40 F to -40 C to —
Unitary Controller 3 AO, 8 DO Floating, Staged On/Off 150 F 65.5 C
PUL1012S Spyder Programmable LonWorks 1 UI, 0 DI, 5 VA Pulse Width Modulation, -40 F to -40 C to —
Unitary Controller 1 AO, 2 DO Floating, Staged On/Off 150 F 65.5 C
PUL1012S-ILC Spyder ILC Programmable LonWorks 1 UI, 0 DI, 5 VA Pulse Width Modulation, -40 F to -40 C to —
Unitary Controller 1 AO, 2 DO Floating, Staged On/Off 150 F 65.5 C
PUL4024S Spyder Programmable LonWorks 4 UI, 0 DI, 5 VA Pulse Width Modulation, -40 F to -40 C to —
Unitary Controller 2 AO, 4 DO Floating, Staged On/Off 150 F 65.5 C
PUL4024S-ILC Spyder ILC Programmable LonWorks 4 UI, 0 DI, 5 VA Pulse Width Modulation, -40 F to -40 C to —
Unitary Controller 2 AO, 4 DO Floating, Staged On/Off 150 F 65.5 C
PUL6438S Spyder Programmable LonWorks 6 UI, 4 DI, 5 VA Pulse Width Modulation, -40 F to -40 C to —
Unitary Controller 3 AO, 8 DO Floating, Staged On/Off 150 F 65.5 C
PUL6438S-ILC Spyder ILC Programmable LonWorks 6 UI, 4 DI, 5 VA Pulse Width Modulation, -40 F to -40 C to —
Unitary Controller 3 AO, 8 DO Floating, Staged On/Off 150 F 65.5 C
PVB6436AS Spyder Programmable VAV BACnet MS/TP 6 UI, 4 DI, 9 VA Pulse Width Modulation, 32 F to 0 C to Integrated Actuator
Controller 3 AO, 6 DO Floating, Staged On/Off 122 F 50 C & Pressure Sensor
PVB6436AS-ILC Spyder ILC Programmable BACnet MS/TP 6 UI, 4 DI, 9 VA Pulse Width Modulation, 32 F to 0 C to Integrated Actuator
VAV Controller 3 AO, 6 DO Floating, Staged On/Off 122 F 50 C & Pressure Sensor
PVB6438NS Spyder Programmable VAV BACnet MS/TP 6 UI, 4 DI, 5 VA Pulse Width Modulation, 32 F to 0 C to Onboard Pressure
Controller 3 AO, 8 DO Floating, Staged On/Off 122 F 50 C Sensor
PVB6438NS-ILC Spyder ILC Programmable BACnet MS/TP 6 UI, 4 DI, 5 VA Pulse Width Modulation, 32 F to 0 C to Onboard Pressure
VAV Controller 3 AO, 8 DO Floating, Staged On/Off 122 F 50 C Sensor
PVL0000AS Spyder Programmable VAV LonWorks 0 UI, 0 DI, 9 VA Pulse Width Modulation, 32 F to 0 C to Integrated Actuator
Controller 0 AO, 0 DO Floating, Staged On/Off 122 F 50 C & Pressure Sensor

342 customer.honeywell.com 70-6910


Spyder Controllers

Controls
Operating

Home
Temperature
Power Range
Network Com- Con-
Product Number Description munications I/O Count sumption Output Type (F) (C) Includes
PVL0000AS-ILC Spyder ILC Programmable LonWorks 0 UI, 0 DI, 9 VA Pulse Width Modulation, 32 F to 0 C to Integrated Actuator
VAV Controller 0 AO, 0 DO Floating, Staged On/Off 122 F 50 C & Pressure Sensor
PVL4022AS Spyder Programmable VAV LonWorks 4 UI, 0 DI, 9 VA Pulse Width Modulation, 32 F to 0 C to Integrated Actuator

Indoor Air Quality


Controller 2 AO, 2 DO Floating, Staged On/Off 122 F 50 C & Pressure Sensor
PVL4022AS-ILC Spyder ILC Programmable LonWorks 4 UI, 0 DI, 9 VA Pulse Width Modulation, 32 F to 0 C to Integrated Actuator
VAV Controller 2 AO, 2 DO Floating, Staged On/Off 122 F 50 C & Pressure Sensor
PVL4024NS Spyder Programmable VAV LonWorks 4 UI, 0 DI, 5 VA Pulse Width Modulation, 32 F to 0 C to Onboard Pressure
Controller 2 AO, 4 DO Floating, Staged On/Off 122 F 50 C Sensor
PVL4024NS-ILC Spyder ILC Programmable LonWorks 4 UI, 0 DI, 5 VA Pulse Width Modulation, 32 F to 0 C to Onboard Pressure
VAV Controller 2 AO, 4 DO Floating, Staged On/Off 122 F 50 C Sensor

Combustion Controls
PVL6436AS Spyder Programmable VAV LonWorks 6 UI, 4 DI, 9 VA Pulse Width Modulation, 32 F to 0 C to Integrated Actuator
Controller 3 AO, 6 DO Floating, Staged On/Off 122 F 50 C & Pressure Sensor

Residential
PVL6436AS-ILC Spyder ILC Programmable LonWorks 6 UI, 4 DI, 9 VA Pulse Width Modulation, 32 F to 0 C to Integrated Actuator
VAV Controller 3 AO, 6 DO Floating, Staged On/Off 122 F 50 C & Pressure Sensor
PVL6438NS Spyder Programmable VAV LonWorks 6 UI, 4 DI, 5 VA Pulse Width Modulation, 32 F to 0 C to Onboard Pressure
Controller 3 AO, 8 DO Floating, Staged On/Off 122 F 50 C Sensor
PVL6438NS-ILC Spyder ILC Programmable LonWorks 6 UI, 4 DI, 5 VA Pulse Width Modulation, 32 F to 0 C to Onboard Pressure
VAV Controller 3 AO, 8 DO Floating, Staged On/Off 122 F 50 C Sensor

Hydronic Controls
Spyder Accessories
Accessories for Spyder Controllers

Dimensions, Approximate: 7.20 in. high x 7.48 in. wide x 2.30 in. deep
(183 mm high x 190 mm wide x 58 mm deep)

Controls
Water
Product Number Description Used With
WB10707 Spyder Micro Wiring Box (must be ordered in multiple of 10) Spyder Micro

Building Automation
Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 343
Building Automation Appliances

REMOTE
MANAGEMENT

PC WITH
WEB BROWSER

INTERNET ETHERNET LAN

WEBVISION
CONTROLLER

LONWorks®

EXCEL 15C EXCEL 10 SMART


UV SmartVFD T7350
CONTROLLER CVAHU VAV

REMOTE
MANAGEMENT

PC WITH
WEB BROWSER

INTERNET ETHERNET LAN

WEBSTAT
CONTROLLER

LONWorks®

T7350 T7350 T7350 T7350

SUITE 1 SUITE 2 SUITE 3 SUITE 4


M16831

344 customer.honeywell.com 70-6910


Building Automation Appliances
WebStat Controller

Controls
Home
WebStat allows you to step up from standalone thermostat control
to the automated T7350 communicating thermostat platform
without incurring any excessive direct digital control (DDC) cost or
complexity. Automation features include web control, alarming,
trending, scheduling, network accessibility, and floor plans.
Operational savings are enabled by remote monitoring, alarming,
floor plan visuals and thermostat assignment privileges for

Indoor Air Quality


tenants, facility managers and contractors. WebStat keeps control
simple by allowing Internet accessibility and flexibility for
assigning user privileges.
• Remote Monitoring
• Remote Programming
• Up to 20 T7350H Thermostats
• Plug-and-Play Setup
• Universal Programming, Commissioning and Graphics Tool
• Alarm Email Notification

Combustion Controls
• Trending
• Thermostat Self-Discovery

Residential
• Wiring Diagram Generation Tool
Dimensions, Approximate: 6 3/8 in. wide x 4 7/64 in. high x 2.5 in. Approvals:
deep (16.2 cm wide x 10.5 cm high x 6.4 cm deep) Canadian Standards Association: CSA C22.2 No. 205-M1983 Signal
Application: Controller Equipment
Application Size: Up to 20 T7350H Thermostats with free software CE: Approved
upgrade Federal Communications Commission: FCC part 15 Class A
Operating Temperature Range: 32 F to 122 F (0 C to 50 C) Underwriters Laboratories, Inc. UL 916, cUL listed

Hydronic Controls
Operating Humidity Range (% RH): 5 to 95% RH, non-condensing
Shipping Temperature Range: 32 F to 140 F (0 C to 60 C)

Network Commissioning
Product Number Description Communications Software Used With Compatible with: Includes
W7350A1000 WebStat Controller LonWorks WebStat LonWorks bus T7350H Communicating Lon Card and Power
Thermostats Supply

WebVision Controller

Controls
Water
WebVision is a low cost building manager with remote monitoring
and programming that allows complete HVAC system management
from a single interface. It is a step-up from WebStat to extend the
scope beyond automated T7350 communicating thermostats to
support HVAC zone and unitary controllers. It also adds several
new features such as Demand Limit Control (DLC) for energy
savings. Without incurring any excessive direct digital control

Building Automation
(DDC) cost or complexity, WebVision offers operational savings by
Internet accessibility, remote monitoring, alarming, and device
assignment privileges for tenants, facility managers and
contractors.
• Web-based monitoring, control, commissioning and programming of
up to 120 LON devices
• Easy installation (plug-and-play setup) of embedded software
• Single universal tool for device configuration and customization of
graphics
• Alarms, Schedules and Trends to completely manage building
automation system

Components
Commercial
• Demand Limit Control (DLC) and VAV Balancing
• Different user profiles - Contractor, Facility Manager and Tenant to
give customized access
Dimensions, Approximate: 6 3/8 in. wide x 4 7/64 in. high x 2.5 in. Approvals:
deep (16.2 cm wide x 10.5 cm high x 6.4 cm deep) Canadian Standards Association: CSA C22.2 No. 205-M1983 Signal
Application: Building Automation Appliance; Controller Equipment
Application Size: Up to 120 LON devices, including EXCEL 10s, CE: Approved
EXCEL 15C, T7350, and VFDs Federal Communications Commission: FCC part 15 Class A
Pneumatic Controls

Operating Temperature Range: 32 F to 122 F (0 C to 50 C) Underwriters Laboratories, Inc. UL 916, cUL listed
Operating Humidity Range (% RH): 5 to 95% RH, non-condensing
Shipping Temperature Range: 32 F to 140 F (0 C to 60 C)

Network Commissioning
Product Number Description Communications Software Used With Compatible with: Includes
WWS-VL1A1000 WebVision LonWorks WebVision LonWorks bus Excel 10s; Excel 15C; T7350H Pre-installed LON card
Controller Communicating Thermostats; and Power Supply
Industrial Combustion
Controls

70-6910 345
Light Commercial Building Systems
LIGHT COMMERCIAL BUILDING SYSTEMS ARCHITECTURE
WEB ACCESS
VIA BROWSER
INTRANET

WEB ACCESS
VIA BROWSER

ETHERNET TCP/IP

EXCEL 15B
BUILDING INTERNET/
MANAGER INTRANET
LONWORKS BUS

RAPIDLINK

EXCEL 15A COMMAND RAPIDZONE™


BUILDING DISPLAY
MANAGER

ZONE CONTROLLERS ZONE CONTROLLER


CONSTANT
VOLUME AHU
• LONSTATION FRONT-END CONTROLLER
SOFTWARE VAV BOX W7750
• LONSPEC CONFIGURATION CONTROLLER ZONE CONTROLLER
SOFTWARE W7751 UNIT
VENTILATOR
CONTROLLER EXCEL 15C
FAN COIL
W7753 PLANT
UNIT
CONTROLLER
CONTROLLER ZONE CONTROLLER
W7752 REMOTE
INPUT/OUTPUT
DEVICE W7761
COMMUNICATING
THERMOSTAT
T7350H
HYDRONIC
CONTROLLER
W7762/3
M23219

346 customer.honeywell.com 70-6910


Light Commercial Building Systems
LonSpec Configuration Software

Controls
Home
• Easy-to-use drag-and-drop setup of LONWORKS® Networks and
devices.
• Excel 10 application-specific controllers come pre-configured to the
most common settings, yet allow quick modifications of parameters
for your application.
• Easy and intuitive configuration of entire control loops.
• No line-by-line programming needed.

Indoor Air Quality


• Automatic and customizable data sharing between controllers on a
network.
• On-line operation with monitoring and diagnostic and manual
functions.
• Convenient right-click floating menus for quick access to LonSpec
functions.
• On-line help includes a Quick Start tutorial for system startup.
• Quickly replicates multiple copies of controllers for repetitive
Excel LONSPEC is a windows based software application for the applications.

Combustion Controls
configuration, commissioning, check out, and monitoring of the • Remote access allows monitoring and diagnosis of system problems
Light Commercial Building Solution (LCBS). The LCBS includes without the inconvenience and expense of service calls.

Residential
the Excel 15A Building Manager, Excel 15C Plant Controller, Excel • Automatic discovery of nodes on a network reduces engineering
10 Constant Volume Air Handling Unit (CVAHU), Excel 10 Variable time.
Volume Air Handling Unit (VAV), Remote Input/Output (RIO) device,
and Unit Vent (UV), Excel 15 Command Display (CD), the T7300F/ Application: Software
Q7300H Series 2000 Commercial Thermostats with Communicating Building Management Interface: LonWorks Bus
Subbases, and T7350H Communication Thermostat, Q7790A Network Communications: LonWorks Bus
Wireless LonWorks® Receiver with T7790C Wireless Wall Module
and Honeywell Variable Frequency Drive.

Hydronic Controls
Product Number Description System Requirements Used With Comments
ZL7760A1020 LonSpec - Software 5.1.0 128 MB RAM, 100 MB disk drive, 500 MHz T7350H Thermostat, Excel 10 family of Excel
microprocessor, Microsoft Windows 2000 or XP controllers, Excel 15 family of controllers LonSpec

LonStation Software
LONSTATION. Software is a Windows® based application/PC
workstation used for monitoring and managing the Light
Commercial Building Solution (LCBS) controllers.

Controls
• Easy-to-use drag and drop setup of LonWorks networks and

Water
devices.
• Configuration, monitoring and binding of LCBS devices.
• Familiar Windows platform user interface Training available through
the Honeywell Authorized Trainer Program.

Application: Software
Building Management Interface: LonStation

Building Automation
Network Communications: LonWorks Bus

Product Number Description Commissioning Software Comments


ZL7762A1026 LonStation - Software 5.1.0 LonSpec Excel LonStation

Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 347
Light Commercial Building Systems
RapidZone Software
• The fastest way to a commercial zoning system.
• Configure and commission an average multiple Rooftop unit job in
less then 60 minutes.
• Ease of use allows a Controls ëNovice’ to successfully configure a
commercial zoning system.
• Produces customized wiring diagrams that clearly define the wiring
of every controller input and output.
• This reduces installation mistakes in the field and improves ease of
future trouble-shooting.
• Flexibility to configure up to 10 different Rooftop systems with up to
18 zones per Rooftop unit, and up to 40 single-zone controllers.
• Roll over help text aids users in the configuration process.
• Ability to replicate similar Rooftop systems and/or Zones simplifies
configuration process.
The RapidZone Solution configures constant volume single zone • Gives a complete materials checklist after the configuration process
HVAC equipment and a series of dampers to maintain the desired is completed.
temperature for up to 18 separate zones per roof top unit (RTU).
Each project can have up to 50 RTU subsystems. Each zone is Application Size: Software
capable of having an adjustable setpoint, a programmable time-of- Building Management Interface: RapidZone
day schedule for each day of the week, and an independent Network Communications: LonWorks Bus
unoccupied override input. The system satisfies the space
temperature setpoints by first reading the space temperature
deviation from setpoint for each zone, then energizing heating or
cooling in the HVAC unit and controlling the position of a supply
damper ducted to each zone. Individual zone dampers modulate
open and closed based on the zone temperature versus setpoint
and the temperature of the RTU discharge air (heating or cooling).

Product Number Description System Requirements


ZL7751A1029 RapidZone 3.0 16 MB RAM, 40 MB disk drive, 90MHz Pentium microprocessor, Microsoft Windows 2000 or XP

Q7770 RapidLink
The Excel 10 Q7770A RapidLink device is a complete network
interface unit for a FTT LonWorks® Bus network. RapidLink is
equipped with an on-board modem that eliminates the requirement
for an on-site modem for remote connections. The Q7770A uses 9
to 24 Vac or Vdc, 9 Vdc power supply using removable screw
terminals or a 9 Vdc barrel connector to perform network
operations. A connector cable attaches the Q7770A to the
LonWorks-Bus port on Excel 10 controllers or wall modules.
• High performance communications protocol provides for faster
communication of data to your LonWorks network.
• Fixed 115,200 bits per second (bps) serial bit rate with auto-baud
detection.
• Uses LonTalk® LonWorks® network protocol.
• 9 to 24 Vac or Vdc power input using removable screw terminals or a
9 Vdc barrel connector.
• Color-coded, removable screw terminals for network and power
wiring.

Building Management Interface: LonWorks Bus


Network Communications: LonWorks Bus

Operating Temperature
Range
Commissioning
Product Number Description Application Software (F) (C) Comments
Q7770A1001 RapidLink Dial Up Interface — 32 F to 100 F 0 C to 38 C Transceiver Type: Transformer isolated,
Network Adapter differential Manchester transceiver Display
Two service LEDs indicate service request
information for each segment; Status LED
indicates when network traffic is occurring;
50000591-001 RapidLink Accessory or LCBS — — —
Accessory Kit (U.S.) Replacement Part

348 customer.honeywell.com 70-6910


Light Commercial Building Systems
W7760A Excel 15 Controller

Controls
Home
• Programmable control of mechanical equipment and auxiliary points.
• Configurable inputs/outputs are expandable with up to three Excel
10 Remote Input/Output (RIO) devices.
• 6 General Purpose Configurable (PID) Control Loops.
• 6 General Purpose Configurable (Non-Linear) Control Loops.
• 8 Start/Stop Control Loops (max of 6 events per day).
• Easy Programming the LonSpec Software. Two piece construction

Indoor Air Quality


for easy installation.
• Easy access to all I/O points for checkout while operations.
• LonTalk® Network communication protocol.
• LonWorks® Free Topology Transceiver (FFT).
• Adaptive Intelligent Recovery.
• Set-Point reset.
The Excel 15 W7760A Building Manager is a LonMark® compliant • Remote Equipment Monitoring and Control.
device that can be used to monitor and control HVAC equipment • 8 schedules of five different occupancy states (when used with a
and other miscellaneous loads in a distributed network. The W7760A Building Manager).

Combustion Controls
optional lithium battery (not included, purchased locally) allows • Demand Limit Control (from a W7760 Building Manager).
continuous power so trend logs and alarms can be maintained for

Residential
up to four continuous years. The W7760A Building Manager
communicates via the 78 kilobaud Echelon® LonWorks® Network,
using a free topology transceiver (FTT).
Dimensions, Approximate: 6 5/32 in. high x 10 19/32 in. wide x Power Consumption: 20 VA (with no DOs), 100 VA (with DOs)
3 7/32 in. deep (156 mm high x 259 mm wide x 82 mm deep) Operating Temperature Range: 32 F to 113 F (0 C to 45 C)
Application: Heat Pump Systems; Boiler; Chiller; Packaged RTU; Built- Shipping Temperature Range: -4 F to +158 F (-20 C to +50 C)
up AHU
Approvals:

Hydronic Controls
Application Size: 20 Nodes Federal Communications Commission: Listed Part 15 Subpart J.
Building Management Interface: LonStation Class A EC Conforms to European Standards
Network Communications: LonWorks Bus Underwriters Laboratories, Inc. UL and cUL listed UL916 as a Class
Commissioning Software: RapidZone; LonSpec 2 device
Frequency: 50 Hz; 60 Hz

Product Number Description I/O Count Output Type Used With Comments
W7760A2011 Excel 15 building 4 DI, 8 AI, Analog/Modulating, Staged On/Off, S7760A Command Can also be used to provide
manager 8 DO, 2 AO Floating, Pulse Width Modulation Display; LonWorks bus timekeeping abilities to the Excel 15C

Controls
Water
W7760B Excel 15 Controller
capabilities when compared to EPROM/RAM based control
devices. The W7760B is configured using built-in utilities. It
queries the LONWORKS® network to determine the devices
installed and self-configures display pages for each supported
device.

Building Automation
• Internet Network appliance with hard drive.
• Supports up to 120 Excel 10 and Excel 15 W7760C controllers.
• Self-discovery of devices (nodes) on the LONWORKS® network.
• Automatically creates a Device Status List (DSL).
The Excel 15 W7760B Building Manager is a Light Commercial • Automatically creates display pages for each supported Excel 10
Building Solution (LCBS) operator interface (network server) and and Excel 15 W7760C controller.
LONWORKS® Bus supervisory device. As an operator interface, it • Automatically configures Trends Log for supported Excel 10 and
connects the user to the Internet, local area network (LAN), or wide Excel 15 W7760C controller.
area network (WAN) providing multi-user access to web pages for • Up to 100 user configured Trend Logs.
Building Manager configuration and LCBS monitoring and • Scheduling of Excel 10 devices and Excel 15 W7760C objects.
command functions. As a building manager, it uses LONWORKS® • Reports and logs alarm data.

Components
Commercial
to provide network wide alarm handling, scheduling, and trend • E-mails reports of alarm data.
logging for application specific XL10 controllers and Excel 15 • View Excel 10 and Excel 15 W7760C data, modify setpoints and
W7760C Plant controllers. The W7760B is a network server/ command Occupied bypass.
appliance equipped with a hard drive. The use of a hard drive • Real Time Clock (RTC) for time stamping with time synchronization.
greatly expands alarm handling, scheduling, and logging • Multi-user access.

Dimensions, Approximate: 6 5/32 in. high x 10 19/32 in. wide x Operating Temperature Range: 41 F to 95 F (5 C to 35 C)
3 7/32 in. deep (156 mm high x 259 mm wide x 82 mm deep) Operating Humidity Range (% RH): 10% to 85% noncondensing
Pneumatic Controls

Application: Heat Pump Systems; Boiler; Chiller; Packaged RTU; Shipping Temperature Range: -4 F to +149 F (-20 C to +65 C)
Built-up AHU
Approvals:
Application Size: 120 nodes Federal Communications Commission: Listed Part 15 Subpart J.
Building Management Interface: Excel 15B Class A EC Conforms to European Standards
Network Communications: LonWorks Bus Underwriters Laboratories, Inc. UL and cUL listed UL916 as a Class
Frequency: 50 Hz; 60 Hz 2 device
Power Consumption: 20 VA

System
Industrial Combustion

Product Number Description Requirements Output Type Used With Comments


W7760B2001 Excel 15 building Internet Explorer Staged On/Off, Graphical Interface, S7760A Command Can also be used to provide
Controls

manager 5.5 or higher Floating, Pulse Width Modulation, Display; timekeeping abilities to the Excel
Analog/Modulating LonWorks bus 15C

70-6910 349
Light Commercial Building Systems
W7760C Excel 15 Controller
The Excel 15 W7760C Plant Controller is used to monitor and
control HVAC equipment and other miscellaneous loads in a
distributed network. The W7760C Plant Controller communicates
via the 78 kilobaud LonWorks Network, using a free topology
transceiver (FTT).
• Programmable control of mechanical equipment and auxiliary points.
• Configurable inputs/outputs are expandable with up to three Excel
10 Remote Input/Output (RIO) devices.
• Eight digital inputs, eight analog inputs.
• Eight optically isolated digital outputs, six 0-20 mA analog outputs.
• Easy programming with LonSpec software.
• Two-piece contruction.
• Easy access to all I/O point for check-out while operational.
• LonTalk Network communication protocol.
• LonWorks Free Topology Transceiver (FTT).

Dimensions, Approximate: 7 1/2 in. high x 5 1/4 in. wide x 1 15/16 in. Operating Temperature Range: -40 F to +150 F (-40 C to +65 C)
deep (191 mm high x 133 mm wide x 49 mm deep) Shipping Temperature Range: -4 F to +122 F (-20 C to +50 C)
Application: Heat Pump Systems; Boiler; Chiller; Packaged RTU;
Approvals:
Built-up AHU Federal Communications Commission: Listed: Part 15 Subpart J,
Building Management Interface: LonStation Class A: European Community Mark: Conforms to European
Network Communications: LonWorks Bus Consortium standards
Voltage: 24 Vac Underwriters Laboratories, Inc. UL/cUL Listed: UL916 (E14480)
Frequency: 50 Hz; 60 Hz
Power Consumption: 18 VA max, with no DOs

Commissioning
Product Number Description Software I/O Count Output Type Used With Comments
W7760C2017 Excel 15C Plant RapidZone; 8 AI, 6 AO, Analog/Modulating, S7760A Designed to be used with the Light
Manager LonSpec 8 DI, 8 DO Pulse Width Modulation, Command Commercial building solution. Requires a
Staged On/Off Display; W7760A be connected to the LonWorks
LonWorks bus bus in order to have scheduling
information

S7760 Excel 15 Command Display


The S7760A Command Display provides local display of system
variables and alarms in a LonWorks® network. The S7760A
Command Display also allows the user to modify setpoints,
schedules and basic system parameters and acknowledge alarms.
Multi-level password protection prevents unauthorized access.
Easy navigation between building and room views allow users to
easily perform the most common tasks.
• Attractive wall-mount packaging.
• Backlit LCD display; 8 lines high by 40 characters wide.
• Two-piece construction for easy installation.
• 10-key keypad for menu-item selection.
• Audible beep when keys are pressed.
• Several layers of display screens provide different views: Buildings,
Rooms, Schedules and Setpoints.
• Local display allows setpoint and schedule changes and alarm
acknowledgment. Password protected with View Only, Bypass,
Setpoint and Schedule levels.
• Cost-effective interface to local HVAC system.
• Low-cost LonWorks’ communications wiring using a Free Topology
Transceiver (FTT).
Dimensions, Approximate: Shipping Temperature Range: -40 F to +150 F (-40 C to +65 C)
7 3/4 in. wide x 4 3/4 in. high x 1 9/16 deep; Subbase 3 3/8 in. wide x 3
Approvals:
3/8 in. deep CE: CE mark; EN50081-1; EN50082-1
(187 mm wide x 121 mm high x 40 mm deep; Subbase 86 mm wide x Federal Communications Commission: Meets FCC part 15 class B
86 mm high) requirements; Listed Part 15 Subpart J. Class A EC Conforms to
Application Size: Small (<20 I/O Points) European Standards
Building Management Interface: LonSpec; RapidZone Approvals, Underwriters Laboratories Inc. UL and cUL listed UL916
Voltage: 20-30 Vac as a Class 2 device
Frequency: 50 Hz; 60 Hz
Operating Temperature Range: 32 F to 120 F (0 C to 45 C)

Network
Product Number Application Description Communications Used With
S7760A2031 LonWorks network Excel 15 Command Display LonWorks Bus Command Display; Excel 15 Controllers; Excel 10 Controllers

350 customer.honeywell.com 70-6910


Light Commercial Building Systems
W7750 Constant Volume Air Handling Unit

Controls
Home
• Factory configured via EEPROM with critical user parameter default
values.
• Uses LonTalk® network (E-Bus) communications protocol.
• High-speed 78 kilobit communications network.
• Conforms with Echelon® LonMark® HVAC Interoperability standard
for Roof Top Unit controllers (profile number 8030).
• Free Topology Transceiver (FTT) network technology is insensitive

Indoor Air Quality


to polarity, simplifying installation.
• Capable of stand-alone operation and has enhanced features
available when using the E-Bus network communications.
• Designed for both staged heating/cooling control and modulating
heating/cooling control.
• Uses either Series 60 Floating Control or PWM (W7750B only)
providing modulating control for heating/cooling equipment.
• Supports two types of economizer control: modulating control and
The W7750A, B, C are LonMark® compliant Constant Volume Air enable/disable control.

Combustion Controls
Handling Unit Controllers used to control single zone and heat • Provides Proportional Integral Derivative (PID) temperature control.
pump air handlers. • Uses an adaptive algorithm (patent pending) that continuously

Residential
• High side triac switching (B and C only). adjusts the discharge air setpoint as needed (W7750B only).
• Freezestat protection for HVAC equipment (B and C only). • Motion sensor interface for enhanced energy savings.
• Analog outputs (C only). • Window sensor input for additional energy savings.
Dimensions, Approximate: 5 5/8 in. high x 6 in. wide x 2 1/8 in. deep Operating Humidity Range (% RH): 5 to 95% RH, non-condensing
(143 mm high x 152 mm wide x 54 mm deep) Setpoint Temperature Range: 45 F to 99 F (7 C to 37 C)
Application: Heat Pump Systems; Packaged RTU Shipping Temperature Range: -40 F to +150 F (-40 C to +65 C)
Application Size: 3 Heat/3 Cool
Approvals:

Hydronic Controls
Network Communications: LonWorks Bus CE: CE Mark
Commissioning Software: LNS Plug-in; RapidZone; LonSpec; CARE Federal Communications Commission: Meets FCC part 15 Class B
Contact Ratings: 7.5 A inrush @ 24 Vac; 1.5 A Run @ 24 Vac requirements EC Conforms to EN50081-1 (CISPR 22 Class B) and
Voltage: 24 Vac EN50082-1
Frequency: 50 Hz; 60 Hz Underwriters Laboratories, Inc. UL 916 (E7741) and cUL (E87741)
Operating Temperature Range: -40 F to +150 F (-40 C to +66 C)

Power
Product Number Description I/O Count Consumption Output Type Used With
W7750A2005 Constant Volume 6 DOs (relay), 3 AI, 3 DI 6 VA Staged On/Off, Floating, See Application Selection

Controls
AHU Controller Pulse Width Modulation Guide (63-7046)

Water
W7750B2011 Constant Volume 6 AI, 5 DI, 12 VA Staged On/Off, Floating, See Application Selection
AHU Controller 8 DOs (triac) Pulse Width Modulation Guide (63-7046)
W7750C2001 Constant Volume 3 AO, 6 AI, 12 VA Staged On/Off, Floating, See Application Selection
AHU Controller 5 DI, 5 DOs (triac) Pulse Width Modulation Guide (63-7046)

Building Automation
Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 351
Light Commercial Building Systems
W7751 Variable Air Volume Controllers
• Uses Echelon® LonWorks® protocol.
• W7751B,D,F use Free Topology Transceiver (FTT) networks and are
compliant with VAV device object type number 8010 functional
LonMark® profile.
• Energy saving setpoint reset for electrical demand limit control.
• Actuator included with W7751H mounts directly onto VAV box
damper shaft and has up to 35 lb. in. torque, 90 degrees stroke, and
90 sec.
• Timing at 60 Hz.
• High speed 78 kilobit communications network.
• Capable of standalone operation, but uses E-Bus network
W7751B communications.
• Easy user-access to the network communications jack.
W7751E • Uses enhanced microbridge-type airflow sensor with dual integral
restrictor design.
• Easy user-access to airflow sensor inputs.
• Provides Proportional Integral Derivative (PID) temperature control.
• Designed for pressure independent Variable Air Volume (VAV)
control.
• Floating hot water and three-stage electric or modulating hot water
heat.
• Provides nonlinear floating algorithm for velocity control loops.
• Individual zone pressurization for supply and exhaust control.
• Factory configured via EEPROM with critical user parameters
default values.
• Motion sensor interface for enhanced energy savings.
• Supports Terminal Regulated Air Volume (TRAV) concept.
• Pressurize and depressurize, night purge, and morning warm-up
W7751D, F sequences supported.
• Wall module options for sensor, setpoint and bypass.
W7751H, J • Software selectable limits on remote setpoint adjustments.
• Three
The W7751B,D and F are VAV II Controllers in the Excel 10 family
product line. These VAV controllers provide pressure independent
or pressure dependent air flow control and series and parallel
(induction) fan control using single and dual duct applications.
VAV systems generally provide cool air only to the zones. The
W7751 controllers provide additional outputs that control VAV box
reheat coils. The heaters can be staged electric or modulating hot
water. Supply and exhaust pressurization control are provided on a
zone basis. W7751H and J Smart VAV Actuator are factory-
integrated VAV Box Controllers with a 90 second ML6161B Direct-
Coupled Actuator in the Excel 10 family product line.
Application: VAV Terminal Box Compatible with: See Application Selection Guide (63-7045)
Network Communications: LonWorks Bus Approvals:
Voltage: 24 Vac with a valid range of 20 to 30 Vac Canadian Standards Association: Listed: File number LR95329-3
Frequency: 50 Hz; 60 Hz CE: UL916
Output Type: Pulse Width Modulation, Floating, Staged On/Off Federal Communications Commission: Meets FCC part 15 Class A
Operating Temperature Range: 32 F to 125 F (0 C to 51.66 C) requirements
Operating Humidity Range (% RH): 5 to 95% RH, non-condensing Underwriters Laboratories, Inc. File number E87741
Setpoint Temperature Range: 45 to 99 F (7 to 37 C)
Shipping Temperature Range: -40 F to +150 F (-40 C to +65 C)

Building Power
Management Commissioning Con-
Product Number Description Interface Software sumption Comments Includes
W7751B2010 Excel 10 VAV II — LNS Plug-in; 10 VA Mountable on Snaptrack —
Controller Printed RapidZone;
Wiring Board LonSpec; CARE
W7751D2016 Excel 10 VAV II — LNS Plug-in; 10 VA Internally wired subbase, UUKL approval —
Controller RapidZone; for use on fire systems
LonSpec; CARE
W7751E1007 Excel 10 series LonStation; CARE — Mounted to standard 4 x 4 in. and 5 x 5 in. —
1000 VAV Excel Building junction boxes or snapped to 35 by 7.5 mm
controller Supervisor EN50 022 DIN Rail. Subbase provides the
(XBS) slotted hole pattern for the R7450 series
IRC devices (118x87 mm)
W7751F2011 Excel 10 VAV II — LNS Plug-in; 10 VA Externally wired subbbase, UUKL approval —
Controller RapidZone; for use on fire systems
LonSpec; CARE
W7751G1003 Excel 10 series LonStation; CARE — Mounted to standard 4 x 4 in. and 5 x 5 in. —
1000 VAV Excel Building junction boxes or snapped to 35 by 7.5 mm
controller Supervisor EN50 022 DIN Rail. Subbase provides the
(XBS) slotted hole pattern for the R7450 series
IRC devices (118x87 mm)

352 customer.honeywell.com 70-6910


Light Commercial Building Systems

Controls
Building Power

Home
Management Commissioning Con-
Product Number Description Interface Software sumption Comments Includes
W7751H2025 Excel 10 Smart — LNS Plug-in; 6 VA UUKL approval for use on fire systems ML6161 Actuator
VAV Actuator RapidZone; mounted directly on
LonSpec; CARE the VAV box
W7751J2004 Excel 10 Smart — LNS Plug-in; 6 VA Does not have pressure sensor, supports ML6161 Actuator

Indoor Air Quality


VAV Actuator RapidZone; maximum pressure dependent only mounted directly on
LonSpec; CARE the VAV box

W7751 Variable Air Volume Handling Unit


Product Number Application Description Used With
206168B XL10 Controller Assembly for W7751F or D, (Bulk pack only, must be purchased in Excel 10 Controllers

Combustion Controls
packs of 10)

Residential
W7752 Fan Coil Unit Controllers
The W7752 Fan Coil Unit Controllers provide room temperature
control for two and four pipe fan coil units with optional electric
heating coils and can control single, two or three speed fans.
Timing and inter-lock features make the W7752 suitable for
systems using electric heat and compressors.

Hydronic Controls
• LonMark® Fan Coil Unit HVAC profile #8020.
• Stand-alone operation or on high-speed 78 kilobit Echelon® Bus (E-
Bus) network direct connection of thermal actuators, fan switch,
electric heat.
• Factory-configured default parameters.
• Wide range of supported valves and actuators.
• Interlocks and time delays to protect equipment.
• Slim design fits into narrow fan coil units.
• Terminations all on one side allow controller to be positioned at back
of fan coil unit.
• Integral 115 Vac or 230 Vac transformer.

Controls
Water
Dimensions, Approximate: Operating Temperature Range: 32 F to 122 F (0 C to 50 C)
4 1/8 in. high x 10 1/8 in. wide x 2 1/2 in. deep Operating Humidity Range (% RH): 5 to 95% RH, non-condensing
(101 mm high x 257 mm wide x 60 mm deep) Setpoint Temperature Range: 32 F to 104 F (0 C to 40 C)
Application: Fan Coil Unit Shipping Temperature Range: -40 F to +150 F (-40 C to +70 C)
Application Size: 3 Heat/3 Cool; 2-pipe; 4-pipe Used With: See Application Selection Guide (63-7043)
Network Communications: LonWorks Bus
Approvals:
Commissioning Software: LNS Plug-in; RapidZone; LonSpec; CARE

Building Automation
CE: CE mark; EN50081-1; EN50082-1
Voltage: 115 Vac (+10%, -15%) Federal Communications Commission: Meets FCC part 15 class B
Frequency: 50 Hz; 60 Hz requirements
Power Consumption: 30 VA maximum

Product Number Description I/O Count Output Type Comments Includes


W7752D2007 Fan Coil Unit 3 AI, 1 DI, 1 DO (3 speed fan Staged On/Off, Floating, 115 Vac power with 250 Vac 10A electric reheat
Controllers control), 2 AO (H/C triacs), 1 DO Pulse Width Modulation electric heat relay relay and 3 fan speed relays
W7752F2002 Fan Coil Unit 3 AI, 1 DI, 1 DO (3 speed fan Staged On/Off, Floating, 115 Vac power with 250 Vac 10A electric reheat
Controllers control), 2 AO (H/C triacs), 1 DO Pulse Width Modulation electric heat relay relay and 3 fan speed relays

Components
Commercial
W7752G2000 Fan Coil Unit 3 AI, 1 DI, 1 DO (3 speed fan Staged On/Off, Floating, 115 Vac power without 3 fan speed relays
Controllers control), 2 AO (H/C triacs), 1 DO Pulse Width Modulation electric heat relay

Pneumatic Controls
Industrial Combustion
Controls

70-6910 353
Light Commercial Building Systems
W7753 Unit Vent Controllers
• Uses standard Echelon® LonMark Unit Ventilator functional profile
for openness and interoperability with Lon Mark devices.
• Applications include unit ventilators with up to two stages heat/cool;
floating heat/cool/economizer, pulse width modulating (PWM) heat/
cool/economizer; ASHRAE Cycles I, II, III.
• Two unused digital outputs can be used as free points controlled by
the network for lighting, exhaust fan.
• Can be used for indoor air quality control using an external sensor/
control and economizer minimum position reset.
• Provides optional energy-saving setpoints for heating/cooling in
unoccupied/occupied and standby modes.
• Optional control sequence shutdown via window/door open digital
input.
• On-board network jacks for quick commissioning and
troubleshooting using the E-Vision configuration tool.
W7753A is a direct digital controller for unit ventilators with • On-board status LED.
staged, floating, or pulse width modulation output using pre • Free topology transceiver (FTT) for flexible installation.
programmed heating, cooling, economizer, and ASHRAE cycles I, • UL94-5V flame-retardant construction.
II, or III algorithms.
Dimensions, Approximate: 5 5/8 in. high x 6 in. wide x 2 1/8 in. deep Setpoint Temperature Range: 55 F to 85 F (13 C to 29 C)
(143 mm high x 152 mm wide x 54 mm deep) Shipping Temperature Range: -40 F to +150 F (-40 C to +65 C)
Application: Unit Ventilator Approvals:
Application Size: 2 Heat/2 Cool Federal Communications Commission: FCC part 15 Class B
Network Communications: LonWorks Bus requirements
Commissioning Software: LNS Plug-in; RapidZone; LonSpec; CARE Underwriters Laboratories, Inc. UL 916
Frequency: 50 Hz; 60 Hz
Power Consumption: 6 VA

Product Number Description I/O Count Output Type Used With Comments
W7753A2002 Unit Ventilator 8 DOs (triac), 2 AI (resistive), 2 AI Staged On/Off, Floating, See Application Selection One T7770 wall
Controller (voltage), 4 DI Pulse Width Modulation Guide (63-7044) module input

W7761 Remote Input/Output Device


The W7761 extends the distribution of input and output devices
across an Echelon network.
• Each input/output is individually controlled from the Zone Manager.
• Uses Echelon LonTalk® communication protocol.
• Free topology transceiver (FTT) for flexible installation.
• On-board network jacks.
• On-board status LED.
• Flame retardant construction (UL94-V5 rated).

Dimensions, Approximate: 5 5/8 in. high x 6 in. wide x 2 1/8 in. deep Operating Humidity Range (% RH): 5 to 95% RH, non-condensing
(143 mm high x 152 mm wide x 54 mm deep) Shipping Temperature Range: -40 F to +150 F (-40 C to +65 C)
Application: Remote I/O
Approvals:
Application Size: 2 Heat/2 Cool Canadian Standards Association: CSA, TUV for Safety Compliance
Network Communications: LonWorks Bus CE: CE Mark
Voltage: 24 Vac with a valid range of 20 to 30 Vac Federal Communications Commission: Listed under FCC Part 15
Frequency: 50 Hz; 60 Hz Level B for EMI compliance
Power Consumption: 6 VA maximum Underwriters Laboratories, Inc. Listed 1784
Operating Temperature Range: -40 F to +150 F (-40 C to +65 C)

Commissioning
Product Number Description Software I/O Count Output Type Comments
W7761A2010 Excel 10 LNS Plug-in; RapidZone; 2 AI (voltage), 4 AI (resistive), Staged On/Off, Floating, UUKL approval for use
Remote IOD LonSpec; CARE 4 DI, 8 DOs (triac) Pulse Width Modulation on fire systems

354 customer.honeywell.com 70-6910


Light Commercial Building Systems
W7762; W7763 Hydronic Controller

Controls
Home
The W7763 Hydronic controllers cover a wide range of control
applications including radiators, induction units, fan coil units with
manual fan switching, and simple VAV. They are suitable for unit
mounting or wall mounting. Controllers operate standalone or as a
part of a LonWorks bus network. Has connections for humidity
sensor and chilled water temperature sensor. Includes
temperature setpoint knob, internal sensor, and bypass button.

Indoor Air Quality


• High efficiency, low cost Heat/Cool valve application solution.
• Model with integrated or remote wall module LonWorks Open
protocol: flexibility now and for the future.
• LonMark profile #8020.
• Direct connection of thermal actuators.
• Wide range of supported valves and actuators.
W7762
W7763

Combustion Controls
Residential
Dimensions, Approximate: 3 5/32 in. high x 4 11/32 in. wide x Operating Humidity Range (% RH): 5 to 95% RH, non-condensing
1 21/32 in. deep (80 mm high x 110 mm wide x 42 mm deep) Setpoint Temperature Range: 32 F to 158 F (0 C to 70 C)
Application: Hydronic Controller Shipping Temperature Range: -4 F to +158 F (-20 C to +70 C)
Application Size: 3 Heat/3 Cool; 2-pipe; 4-pipe
Approvals:
Network Communications: LonWorks Bus Canadian Standards Association: Listed: File No. LR95329-3
Voltage: 24 Vac ± 20% Underwriters Laboratories, Inc. Component Recognized: File No.
Frequency: 50 Hz; 60 Hz SA481
Power Consumption: 0.5 VA maximum (no load)

Hydronic Controls
Operating Temperature Range: 32 F to 122 F (0 C to 50 C)

Commissioning
Product Number Description Software Output Type Comments Includes
W7762B1027 Excel 10 Hydronic LNS Plug-in; Multi-stage Electric; Pulse Width 2 inputs and 2 —
Controller RapidZone; LonSpec; Modulation; Floating; Staged On/Off control outputs
CARE
W7763C1016 Excel 10 Hydronic LNS Plug-in; Floating, Pulse Width Modulation, 3 Inputs, 2 Control An integral setpoint knob, sensor,
Controller RapidZone; LonSpec; Staged On/Off, Multi-stage Electric Outputs bypass button, and LED
CARE

Controls
W7763C1032 Excel 10 Hydronic LNS Plug-in; CARE Floating, Pulse Width Modulation, Relative Setpoint An integral setpoint knob, sensor,

Water
Controller Staged On/Off, Multi-stage Electric Adjustment bypass button, and LED

Y7751-W7751F VAV Unit Controller and ML6161B Actuator


The W7751F2003 VAV II Controller is from the Excel 10 family
product line. VAV controllers provide pressure independent or

Building Automation
pressure dependent air flow control and series and parallel
(induction) fan control using single and dual applications. The
W7751F controllers provide additional outputs that control VAV
box reheat coils. The ML6161B2024 is used to control dampers in
VAV terminal units and for mounting on ball valves.
• Uses Echelon LonWorks Protocol.
• High Speed 78 kilobit communications network.
• Easy user-access to the network communications jack.
• Easy user-access to the airflow sensor inputs.
• Provides Proportional Integral Derivative (PID) temperature control.
• Designed for pressure independent Variable Air Volume (VAV)

Components
Commercial
control.
• Floating hot water and three-stage electric or modulating hot water
heat.
• Provides nonlinear floating algorithm for velocity control loops.
• Factory configured via EEPROM with critical user parameters
default values.
• ML6161B2024 is a Direct Couple, General Purpose, Non-Spring
Return Actuator.
Pneumatic Controls

• Rated at 35 lb-in. torque with a 90 degree stroke.

Building Management Interface: EBI; SymmetrE; ACSELON

Network Commissioning
Product Number Application Description Communications Software Includes
Y7751F2001 VAV Controller with FFT base Package containing a LonWorks Bus LNS Plug-in; RapidZone; One W7751F 2003 and
with enclosure and outward W7751F VAV Controller LonSpec; CARE one ML6161B 2024
facing terminal strips and a ML6161 Actuator
Industrial Combustion
Controls

70-6910 355
Legacy Building Systems
Q667 Switching Subbase
Provide manual switching for T7067 Thermostat/Transmitters.
• Mount directly on wall or on vertical 2 x 4 in. outlet box.
• T7067 mounts on subbase with mounting screws which also
complete electrical connections between thermostat/transmitter and
subbase.
• When fan switch is set to AUTO, the fan is intermittent in HEAT and
continuous in system AUTO or COOL.

Dimensions, Approximate: 4 3/4 in. high x 3 15/16 in. wide x 15/16 in.
deep (121 mm high x 100 mm wide x 24 mm deep)
Power Consumption: 1A at 24 Vac Full Load

Switch Positions
Product Number Application System Fan Comments Used With
Q667A1005 Heat Pump Systems, HEAT-OFF-COOL- AUTO/ON Number of stages of heating and cooling T7067
Split Systems AUTO depends on the chosen Logic Panel
Q667B1004 Heat Pump Systems, HEAT-OFF-COOL- AUTO/ON Number of stages of heating and cooling T7067
Split Systems AUTO depends on the chosen Logic Panel
Q667B1020 Heat Pump Systems, HEAT-OFF-COOL- AUTO/ON Provides intermittent fan operation in T7067
Split Systems AUTO cooling when used with W974B
Q667C1003 Single Stage Subbase COOL/AUTO/HEAT/ AUTO/OFF; OFF position — T7067
EM.HT. shuts off entire system

T7067 Thermostat and Transmitter


T7067A Thermostat and T7067B Transmitter control space
temperature when used with W973 Logic Panel.
• Separate heat and cool adjustable set point levers provide
adjustable deadband from 3 F to 30 F (2 C to 17 C).
• Separate 1-16 Vdc voltage ramps provide independent heating and
cooling signals to W973 Single Zone Logic Panel.
• Two light-emitting diodes (LEDs) under T7067 cover for system
checkout.
• C7046A Discharge Air Sensor provides temperature anticipation.
• One T7067 can control up to 6 W973 panels in parallel.
• Mount on standard 2 x 4 in. vertical outlet box or on a non-
conductive flat surface.
• All models include wiring plate and locking cover.

Application: Module Compatible With: Q667 subbase, W973 Logic Panel


Application Size: Depends on Logic Panel (W973)
Approvals:
Control System: W973 single zone
ASHRAE Guidelines: Meets ASHRAE 90-75
Output Type: Voltage Ramp Department of Defense Guidelines: Meets
Dimensions, Approximate: 4 5/8 in. high x 2 13/16 in. wide x 1 1/4 in.
deep (118 mm high x 71 mm wide x 32 mm deep) Accessories:
Voltage: 20 Vdc from W973 panel S963D1001 2 Potentiometers that simulate the ramp signals of a T7067
Setpoint Temperature Range: 55 F to 85 F (13 C to 29 C) Thermostat
Shipping Temperature Range: -40 F to +150 F (-40 C to +65 C)

Product Number Description Comments


T7067A1008 Solid State Thermostat designed to be used with the W973 logic panel Integral temperature sensor without thermometer; Number of
to control the operation of single zone packaged air conditioning stages of heating and cooling depends on the chosen Logic
equipment. Panel
T7067B1006 Transmitter designed for use with a T7047C1025 or T7022A1010 Must order T7047C,G remote temperature sensor or T7022A
remote temperature sensor remote duct temperature sensor separately

356 customer.honeywell.com 70-6910


Legacy Building Systems
T7080 Electronic Dual Setpoint Thermostat

Controls
Home
Used in W7080 control system to provide modulating space
temperature control.
• Separate heat and cool adjustable set point levers provide
adjustable deadband from 3 F to 30 F (2 C to 17 C).
• Single 2 to 22 Vdc voltage ramp provides heating/cooling signal to
W7080 Load Analyzer.
• Outputs constant 12 Vdc when sensed temperature is within

Indoor Air Quality


deadband range.
• Ramp output decreases on call for heat: increases on call for
cooling.
• C7100B or C7046B Air Temperature Sensors are used to provide
heating/cooling anticipation (one required for each zone thermostat)
and can also be optionally used as remote return air temperature
sensors with the T7080B transmitter.
• Operates on 24 Vdc supplied by W7080A Load Analyzer.
• Mounts on standard 2 x 4 in. outlet box or on nonconductive flat

Combustion Controls
surface.

Residential
Dimensions, Approximate: 4 5/8 in. high x 2 13/16 in. wide x 1 1/4 in. Approvals:
deep (118 mm high x 71 mm wide x 32 mm deep) ASHRAE Guidelines: Meets ASHRAE 90-75
Voltage: 24 Vdc (13 C to 29 C) Department of Defense Guidelines: Meets
Setpoint Temperature Range: 55 F to 85 F
Shipping Temperature Range: -40 F to +150 F (-40 C to +65 C)

Product Number Application Application Size Control System Output Type

Hydronic Controls
T7080A1019 Split System, Furnace, Packaged RTU 3 Heat/3 Cool W7080 control system Voltage Ramp
T7080B1017 Split System, Heat Pump Systems, Furnace, Packaged RTU 3 Heat/3 Cool W7080 control system Voltage Ramp

W7080 Load Analyzer


Controls heating, cooling and space demand oriented economizer
operation in the Honeywell Electronic Dual Set point Multizone
control system.
• Controls 3 stages of on/off heating, modulated heating, modulated
economizer, 3 stages of on/off cooling and modulated cooling.

Controls
• Responds to highest heating and cooling demand signal from up to

Water
12 T7080 Zone Thermostat/Transmitters.
• Analyzer is short-circuit protected source of 24 Vdc power for zone
thermostat/transmitter, sensor and W7081A Limit Controller
Package.
• Switches all stages off when power is interrupted; switches stages
on when power is restored.
• Compressor turn-on time delays must be incorporated for each

Building Automation
compressor.
• No adjustment or calibrations required.
• Night setback and cooling shutdown for individual or all zones by
addition of time-clock.
• Mounts with 4 No. 8 Screws (not provided) through holes in base.
Dimensions, Approximate: 6 1/4 in. high x 4 1/8 in. wide x 2 5/16 in. Shipping Temperature Range: -40 F to +150 F (-40 C to +65 C)
deep (159 mm high x 105 mm wide x 59 mm deep) Compatible With: T7080 Thermostat
Contact Ratings: NO 240 VA inrush @ 24 Vac, 60 VA running @ 24 Approvals:
Vac; NC 75 VA inrush @ 24 Vac, 30 VA running @ 24 Vac ASHRAE Guidelines: Meets ASHRAE 90-75
Electrical Connections: 1/4 in. quick-connect male terminals

Components
Canadian Standards Association: Component Recognized

Commercial
Voltage: 24 Vdc Department of Defense Guidelines: Meets
Frequency: 60 Hz; 50 Hz Underwriters Laboratories, Inc. Component Recognized
Operating Temperature Range: -40 F to +150 F (-40 C to +65 C)

Product Number Application Application Size Control System Comments


W7080A1016 Split System, Furnace, 3 Heat/3 Cool W7080 control Load analyzer provides control of On/Off and modulated cooling
Packaged RTU system and modulated economizer functions
Pneumatic Controls
Industrial Combustion
Controls

70-6910 357
Legacy Building Systems
W7081 Limit Controller
Used with W7080A Load Analyzer to provide cold deck low limit,
hot deck high limit, and economizer/mixed air low limit functions.
• Limits the maximum and minimum temperatures of the hot and cold
deck and of the mixed air by supplying modified demand signals to
the W7080A Load Analyzer and to the economizer.
• The positive limits stabilize deck temperatures under light load
conditions providing greater comfort and reducing energy usage.
• Has jumper selectable set points for each of its 3 functions.
• Compact to fit easily in HVAC system control panel.
• Mounts with 4 No. 8 screws (not provided) through holes in base.

Dimensions, Approximate: 6 1/4 in. high x 4 1/8 in. wide x 2 5/16 in. Approvals:
deep (159 mm high x 105 mm wide x 59 mm deep) ASHRAE Guidelines: Meets ASHRAE 90-75
Electrical Connections: 1/4 in. quick-connect male terminals Canadian Standards Association: Component Recognized
Power Consumption: 0.29 VA maximum Department of Defense Guidelines: Meets
Operating Temperature Range: -40 F to +150 F (-40 C to +65 C) Underwriters Laboratories, Inc. Component Recognized
Shipping Temperature Range: -40 F to +150 F (-40 C to +65 C)

Product Number Application Application Size Control System Compatiable with:


W7081A1015 Split System, Heat Pump Systems, Furnace, Packaged RTU Small (<20 I/O Points) W7080 control system W7080 Load analyzer

W7100A,C Discharge Air Temperature Controller


Maintain an average discharge air temperature in variable air
volume (VAV) systems, or other systems requiring discharge air
control of multistage cooling or heating. Reduce kilowatt demand
and consumption by maintaining the minimum amount of heating
or cooling capacity required to hold the discharge air set point.
Utilize economizer for free cooling when available.
• W7100 Controller maintains an average discharge air temperature in
variable air volume (VAV) cooling systems by modulating an
economizer and sequencing stages of mechanical cooling.
• The W7100 can be applied to electric makeup air and other systems
requiring discharge air control of multistage heating or cooling.
• Staging capacity of the W7100A,C can be extended six stages using
a W7101A Satellite Sequencer.
• When power is interrupted, the system cycles to all stages off.
• When power is restored, the economizer will first be modulated open
(if enthalpy is suitable), then stages of mechanical cooling will be
sequenced on.
• If enthalpy is not suitable for economizer operation, the first stage of
cooling or heating is energized within five minutes.
• Reset signal from either space sensor or outdoor air sensor.
Dimensions, Approximate: 8 5/8 in. high x 6 1/2 in. wide x 3 in. deep Power Consumption: 12 VA at 24 Vac, 50/60 Hz (max).
(219 mm high x 161 mm wide x 76 mm deep) Operating Temperature Range: 40 F to 90 F (4 C to 32 C)
Contact Ratings: Setpoint Temperature Range: 40 F to 90 F (4 C to 32 C)
NO 240 VA inrush @ 24 Vac, 60 VA running @ 24 Vac Shipping Temperature Range: -40 F to +150 F (-40 C to +65 C)
NC 75 VA inrush @ 24 Vac, 30 VA running @ 24 Vac
NO 750 VA inrush @ 120/240 Vac, 75 VA running @ 120/240 Vac Accessories:
NC 240 VA inrush @ 40 Vac, 30 VA running @ 24 Vac S963B1037 Manual Potentiometer (480 ohm)
Electrical Connections: 1/4 in. quick-connect male terminals S963B1078 Manual Potentiometer (500 ohm)
Voltage: 20 to 30 Vac S963B1128 Manual Potentiometer (135 ohm)
Frequency: 60 Hz; 50 Hz

Product Number Application Size Control System Output Type Comments


W7100A1053 0 Heat/6 Cool W7100 family Staged On/Off Additional stages of heating and cooling can be achieved by adding
a W7101 Satellite Sequencer
W7100C1018 2 Heat/4 Cool W7100 family Staged On/Off Additional stages of heating and cooling can be achieved by adding
a W7101 Satellite Sequencer

358 customer.honeywell.com 70-6910


Legacy Building Systems
W7100G Discharge Water Temperature Controller

Controls
Home
Controls discharge water temperature in reciprocating chiller and
cooling tower applications.
• The W7100G maintains average discharge water temperature by
staging on and off compressors, unloaders of water tower fans as
required.
• Provides up to six stages of cooling.
• Use W7101A for expanding up to 10 cooling stages.

Indoor Air Quality


• Advanced proportional plus integral microprocessor control
algorithm minimizes droop.
• Soft start to minimize compressor cycling during system start up.
• Adjustable minimum on/off timing and time delay between stages of
either 30 or 60 seconds.
• Reset of discharge water temperature based on either outdoor air or
space sensor signal.
• Use C7170 Sensor for sensing water temperature.
• LEDs indicate which stages of cooling are energized.

Combustion Controls
• Use S963B Potentiometer for remote set point capability.

Residential
Dimensions, Approximate: 8 5/8 in. high x 6 1/2 in. wide x 3 in. deep Frequency: 60 Hz; 50 Hz
(219 mm high x 161 mm wide x 76 mm deep) Power Consumption: 12 VA at 24 Vac, 50/60 Hz (max).
Contact Ratings: Operating Temperature Range: -40 F to +150 F (-40 F to +150 F)
NO 240 VA inrush @ 24 Vac, 60 VA running @ 24 Vac Shipping Temperature Range: -40 F to +150 F (-40 C to +65 C)
NC 75 VA inrush @ 24 Vac, 30 VA running @ 24 Vac
NO 750 VA inrush @ 120/240 Vac, 75 VA running @ 120/240 Vac Accessories:
NC 240 VA inrush @ 40 Vac, 30 VA running @ 24 Vac S963B1037 Manual Potentiometer (480 ohm)
Electrical Connections: 1/4 in. quick-connect male terminals S963B1078 Manual Potentiometer (500 ohm)

Hydronic Controls
Voltage: 20 to 30 Vac S963B1128 Manual Potentiometer (135 ohm)

Product Number Application Size Control System Output Type Compatiable with: Comments
W7100G1001 0 Heat/6 Cool W7100 family Staged On/Off W7101 Satellite Expansion 4 additional stages of cooling can be
Module added with W7101A

W9076 Digital Temperature Indicator


The W9076 digital temperature indicator provides continuous led

Controls
(light-emitting diode) digital display of temperature in commercial

Water
building applications. Display permits user selection of fahrenheit
or celsius readings in the range of -40 F to 199 F (-40 C to 93 C).
Several locations can be monitored on the display through suitable
switching of additional remote sensors.
• Fahrenheit or Celsius display is field selectable.
• Solid state sensor provides fast response, accurate temperature
readings.

Building Automation
• The 3-1/2 digit LED display has 0.3 inch numerals.
• Front mounting permits fast, easy installation.
Application: Monitors temperature in space or ducts, and fluid in hot or 121371A Copper. Bulb size: 3/8 in. x 3 in. (10 mm x 76 mm). Well size:
cold water pipes 3 in. (76 mm) insertion, 1 1/2 in. NPT. Includes mounting clamp.
Dimensions, Approximate: 4 9/16 in. high x 1 15/16 wide x 2 3/4 in. 131524A Capillary Holder Assembly., 8 3/8 in. long, duct insertion
deep (116 mm high x 49 mm wide x 70 mm deep) 230038A Replacement Faceplate Lens for use with W9076
Contact Ratings: 49 mm dia, 70mm long
Voltage: 24 Vac, +25%, -15%. For each volt above 26 Vac, derate Replacement Parts:
ambient temperature by 5 F (2.8 C) 107324A Capillary Holder Assembly for duct insertion, 8 3/8 in. long
Frequency: 60 Hz; 50 Hz 121371A Copper. Bulb size: 3/8 in. x 3 in. (10 mm x 76 mm). Well size:

Components
Commercial
Operating Temperature Range: -40 F to +199 F (-40 C to +93 C) 3 in. (76 mm) insertion, 1 1/2 in. NPT. Includes mounting clamp.
121371E Stainless steel. Bulb size: 3/8 in. x 3 in. (10 mm x 76 mm).
Accessories: Well size: 3 in. (76 mm) insertion, 1 1/2 in. (38 mm) insulation, 1/2 in.
107324A Capillary Holder Assembly for duct insertion, 8 3/8 in. long (13 mm) NPT. Includes mounting clamp.
131524A Capillary Holder Assembly., 8 3/8 in. long, duct insertion

Product Number Description Comments Includes Used With


Pneumatic Controls

W9076A1000 Digital Temperature indicator that Solid state sensor 194950E T7047C1090 Case (for wall mounting the remote sensor),
provides a continuous LED display usable up to 300 ft Sensor 121371A Immersion Well, 131524A/107324A/311266D Holders
for temperature (includes sensor) (91 m) for duct mounting sensor, 107408 Heat-inductive compound
W9076A1018 Digital Temperature indicator that Monitors temperature — 194950E Sensor, T7047C1090 Case (for wall mounting the
provides a continuous LED display is space or ducts, and remote sensor), 121371A Immersion Well, 131524A/107324A/
for temperature (does not include fluid in hot or cold 311266D Holders for duct mounting sensor, 107408 Heat-
sensor) water pipes inductive compound
Industrial Combustion
Controls

70-6910 359
Legacy Building Systems
W973 Logic Panel
• Proven, reliable temperature control.
• Many flexible versions to meet your application needs.
• Panels can be used with staged gas, oil, or electric heat; modulating
gas, hot water, or steam heat; and direct expansion or modulating
chilled water cooling.
• Control up to 3 on-off heat or cool stages or up to 10 on-off heat and/
or cool stages using W975 Satellite Sequencers.
• Modulating dc current signal controls economizer heating or cooling
valve motors.
• T7067 Dual Set Point Thermostat/Transmitter located in controlled
space provides heating and cooling input signal based on space
demand.
• C7046A sensor located in discharge air duct provides heating/
cooling anticipation and economizer modulating low limit signal.
• System cycles all stages off on power interruption.
• When power is restored, system sequences required stages on with
Control heating, cooling and economizer operation in commercial timed inter-stage delay.
air conditioning and heat pump equipment.
Dimensions, Approximate: 6 1/4 in. high x 4 1/8 in. wide x 2 5/16 in. Operating Temperature Range: -40 F to +150 F (-40 C to +66 C)
deep (159 mm high x 105 mm wide x 59 mm deep) Shipping Temperature Range: -30 F to +150 F (-34 C to +65 C)
Contact Ratings: Compatible With: T7067 Thermostat with Q667 subbase
NO 240 VA inrush @ 24 Vac, 60 VA running @ 24 Vac
Approvals:
NC 75 VA inrush @ 24 Vac, 30 VA running @ 24 Vac Canadian Standards Association: File No. LR95329-3
Electrical Connections: 1/4 in. quick-connect male terminals Underwriters Laboratories, Inc. Component Recognized: File No.
Voltage: 24 Vac SA481
Frequency: 60 Hz; 50 Hz
Power Consumption: 8 VA

Application
Product Number Application Size Control System Output Type Comments
W973A1017 Split System, Heat Pump Systems, 2 Heat/2 Cool W973 single zone Staged On/Off —
Furnace, Packaged RTU
W973B1016 Split System, Heat Pump Systems, 3 Heat/3 Cool W973 single zone Staged On/Off Provides modulating heating output and
Furnace, Packaged RTU modulating cooling output
W973E1005 Split System, Heat Pump Systems, 0 Heat/4 Cool W973 single zone Staged On/Off —
Furnace, Packaged RTU
W973J1017 Split System, Heat Pump Systems, 4 Heat/4 Cool W973 single zone Staged On/Off —
Furnace, Packaged RTU

Environmental Control Systems Accessories


Product Number Description Used With
230038A Replacement Faceplate Lens for use with W9076 W9076
S963B1003 Manual Potentiometer (360 ohm) T7022; T7023
S963B1037 Manual Potentiometer (480 ohm) —
S963B1078 Manual Potentiometer (500 ohm) —
S963B1086 Manual Potentiometer (1000 ohm) —
S963B1128 Manual Potentiometer (135 ohm) —
S963B1136 Manual Potentiometer (270 ohm) —
S963B1177 Manual Potentiometer (480 ohm) —

S963D1001 2 Potentiometers that simulate the ramp signals of a T7067 Thermostat —

360 customer.honeywell.com 70-6910


Pressure Controllers
P906 Differential Pressure Controllers

Controls
Home
The P906 controllers respond to increases and decreases in
pressure difference between high and low pressures in water or
steam systems. The P906 provides proportional control in low
voltage circuits and can be used to control a proportional valve to
maintain desired pressure difference between two points in a
system.
• P906 provides proportional control using a 135-ohm potentiometer.

Indoor Air Quality


• Adjustable main spring determines pressure difference at which
controller operates and against which difference in high and low
pressure must act.
• Three mounting lugs furnished on each device to facilitate
installation.
• Blank scale supplied for marking as required.

Combustion Controls
Dimensions in inches (millimeters) Application: Water and Steam, Electric Control, Output: 135 Ohm
Connection Size: Includes (2) 1/4 x 1/2 in. NPT couplings for

Residential
3-5/16 connecting to flexible steam hose (8 in. min)
A (84) Output: 135 Ohm

7-7/8
(200)

Hydronic Controls
3-3/4 (95)

DIMENSION A PRESSURE DIFFERENCE RANGE


INCHES (MM) PSI kPa

11-7/16 (291) 0-10 0-69

Controls
Water
9-11/16 (246) 0-45, 0-50, 0-70 0-310, 0-345, 0-483
9-7/16 (240) 10-300 69-2068 M27433

Differential Pressure
Pressure Range Range
Product Number (psi) (kPa) (psi) (kPa) Comments

Building Automation
P906A1040 5 to 225 psi 35 to 1551 kPa 0 to 70 psi 0 to 483 kPa Controls a proportional valve to maintain a selected pressure difference
between two points.

Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 361
Refrigeration Controllers
L480; L482 Refrigeration Controller
Used to limit or control temperature in air conditioning systems or
refrigerated enclosures.
• Applications include freezer cabinets, display cases, beverage
coolers, milk cooling tanks and air conditioners.
• Can act as a frost alarm operator in storehouses or orchards where
frost would damage crops or equipment.
• Dual temperature scaleplate provided for both Fahrenheit and
Celsius readings.

L482 Dimensions in inches (millimeters) L480 Dimensions in inches (millimeters)

4 (101) 7/8 (22) DIAMETER HOLE


PUSH FOR 1/2 INCH CONDUIT
SETPOINT TO MANUAL RESET CONNECTION
ADJUSTMENT RESET MODEL ONLY 1-1/16
SCREW (27)

2-9/16 (65)
3-5/16 (MANUAL
(84) RESET
4-11/16 MODEL
(119) 3/16
(5) (2) ONLY)

2-9/32
(58)

1-1/16
5/16 (27) (2)
SETPOINT
(8) (2)
SCALE

7/8 (22) HOLE


FOR 1/2 CONDUIT
WITH 1-3/32 (28)
20 FT BY 1/8 INCH KNOCKOUT RING
SENSING ELEMENT FOR 3/4 CONDUIT
3-5/16 (84) 2-5/16 (59)
3-11/16 (94) M11026A

2-3/32
(53)
Type: Averaging element
3/8 X 3/16 Sensor Element: Coldest point on the capillary
(10 X 5) Voltage: 120 Vac; 240 Vac
DIAMETER
ELONGATED
Frequency: 60 Hz; 50 Hz
MOUNTING
1-7/8
(48)
3/16 (5)
DIAMETER
Capillary Length: 20 ft. (6.1 m)
HOLE MOUNTING
HOLE Approvals:
Canadian Standards Association: Certified: File No. LR95329-1
1-1/8 (29) Underwriters Laboratories, Inc. File: SA481, Guide: SDFY
5/16
(8) Contact Ratings (120 Vac) Contact Ratings (240 Vac)
1 (25)
L480 10.2 AFL, 61.2 ALR 6.5 AFL, 39.0 ALR

MOUNTING
L482 Aux: 6.0 AFL, 36.0 ALR Aux: 3.0 AFL, 18.0 ALR
HOLES (2) Main: 8.0 AFL, 48.0 ALR Main: 5.1 AFL, 30.6 ALR
10-32 UNF-2B
THREAD

5/16 (8) 3-1/4 (83) C606A

Setting Maximum
Temperature Differential Operating
Range Temperature Temperature
Product Number Application (F) (F) (C) (F) (C) Switching Comments
L480B1239 Acts as frost alarm in storehouses, orchards, or 20 F to 60 F 10 F 5.6 C 125 F 52 C 1 SPDT —
other locations where frost could damage crops
or equipment.
L480G1044 For temperature or limit control of air conditioning 20 F to 60 F 15 F 8C 125 F 52 C 1 SPST Manual reset
systems and refrigeration units.
L482A1004 Provides temperature or limit control of air 15 F to 55 F 5F 2.8 C 140 F 60 C 2 SPST, one Manual reset
conditioning systems by operating electric motors N.O., one N.C.
for dampers, valves, compressors, or fans.

362 customer.honeywell.com 70-6910


Refrigeration Controllers
T4031A; T6031A Refrigeration Temperature Controller

Controls
Home
Provide limit or temperature control in refrigerated areas where
remote mounting of sensing element is required.
• Liquid-filled copper elements provide rapid sensing to control the
compressor system.
• Control temperature in a duct, tank, freezer or cooler.
• Controller element can be directly immersed in the controlled
medium.

Indoor Air Quality


• Adjustable control setpoint.
• Ambient temperature compensation provides good temperature
control.
• Refer to T775 Electronic Remote Temperature Controller where
more exact control is required and/or remote controller location is
preferred.

Combustion Controls
Dimensions in inches (millimeters) Type: Remote bulb

Residential
Bulb Size: 3/8 in. diameter x 3 in. long (10 mm diameter x 76 mm long)
Maximum Operating Temperature: 125 F (52 C)
Voltage: 120 Vac; 240 Vac
Sensor Element: Copper bulb
Contact Ratings (120 Vac): 8.0 AFL, 48.0 ALR
Contact Ratings (240 Vac): 5.1 AFL, 30.6 ALR
Approvals:

Hydronic Controls
Canadian Standards Association: Certified: File No. LR95329-1
Underwriters Laboratories, Inc. File: SA481, Guide: SDFY

Controls
Water
Building Automation
Components
Commercial
Setting Temperature Range Differential Temperature Capillary Length
Product Number (F) (C) (F) (C) Switching (m) (ft) Comments
T4031A1073 -30 F to +50 F — 3.5 F — 1 SPST 2.44 m 8 ft. —
T6031A1011 15 F to 90 F — 3.5 F to 16 F — 1 SPDT 1.5 m 5 ft —
• T6031A1029 -30 F to +90 F — 3.5 F to 16 F — 1 SPDT 2.4 m 8 ft. —
Pneumatic Controls

T6031A1052 -30 F to +90 F — 3.5 F to 16 F — 1 SPDT 1.5 m 5 ft —


T6031A1060 -30 F to +90 F — 3.5 F to 16 F — 1 SPDT 6.1 m 20 ft. —
T6031A1086 — -35 C to +30 C — 1.9 C to 8.9 C 1 SPDT 2.4 m 8 ft. Celsius model
T6031A1136 -30 F to +90 F — 3.5 F to 16 F — 1 SPDT 2.4 m 8 ft. —
* TRADELINE models • SUPER TRADELINE models
Industrial Combustion
Controls

70-6910 363
Sail Switches
S437; S637 Sail Switch
The S437 and S637 Sail Switches respond to the air velocity in
heating or warm air ducts, such as used in farm crop dryers. The
switch completes a 24V or line voltage burner control circuit only
when the blower or fan has produced a predetermined air velocity.
• Micro Switch SPDT snap switch is operated by metal sail inserted in
an air stream.
• Has a set of normally closed contacts which can be used to energize
a signal or warning circuit when the velocity drops off.
• Sail can trimmed to one-half the original size to double the velocity
required to close the snap switch contacts.
• Switch differential can be manually adjusted by turning a knurled
knob on the snap switch.
• A conduit knockout is located on each end of the case for wiring
convenience.
Dimensions, Approximate: 2 15/16 in. high x 3 3/4 in. wide x 2 in. Approvals:
deep (59 mm high x 95 mm wide x 51 mm deep) Canadian Standards Association: CSA: Guide: MFHZ
Insertion Length: 3 1/2 in. (89 mm) Underwriters Laboratories, Inc. UL: File: MP2618
Maximum Ambient Temperature: 150 F (66 C)
Operating Velocity: 1900 fpm-2250 fpm (9.7 m/s-11.4 m/s)

Contact Ratings Sail Dimensions


Product Number (AFL) (ALR) Switching (inch) (mm)
S437A1009 15.0 A @ 6 Vdc; 7.5 A @ 12 Vdc; 2.0 A @ 24 Vac; 48.0 A @ 120 Vac; 1 SPST 1 in. x 3 in. 25 mm x 76 mm
8.0 A @ 120 Vac; 5.1 A @ 240 Vac 30.6 A @ 240 Vac
S437A1025 15.0 A @ 6 Vdc; 7.5 A @ 12 Vdc; 2.0 A @ 24 Vac; 48.0 A @ 120 Vac; 1 SPST 1 1/2 in. x 4 in. 38 mm x 102 mm
8.0 A @ 120 Vac; 5.1 A @ 240 Vac 30.6 A @ 240 Vac
S637A1004 15.0 A @ 6 Vdc; 7.5 A @ 12 Vdc; 2.0 A @ 24 Vac; 48.0 A @ 120 Vac; 1 SPDT 1 in. x 3 in. 25 mm x 76 mm
8.0 A @ 120 Vac; 5.1 A @ 240 Vac 30.6 A @ 240 Vac

364 customer.honeywell.com 70-6910


Temperature Controllers
T4031C; T6031C,D,F Ambistat Controller

Controls
Home
Ambient temperature compensated, high-limit controllers for
agriculture and industrial applications.
• Suitable for line-voltage, low voltage, or millivolt (Powerpile) control
of bulk milk tanks, beverage dispensing machines, ice cube
machines, dishwashers, crop drying, tobacco curing, and similar
applications.
• Enclosed snap action switches available with SPST or SPDT action.

Indoor Air Quality


• Models available that make or break on temperature rise.
• Screwdriver adjustment for temperature setting; external knob
option.
• Immersion well not included.

Combustion Controls
Dimensions in inches (millimeters)

Residential
Type: Remote bulb
Application: Line-voltage, low-voltage or millivolt (Powerpile) control of
15/16 bulk milk tanks, beverage dispensing machines, ice cube machines,
KNOCKOUT FOR
(24)
1/2 CONDUIT (BOTH ENDS)
dishwashers, crop drying, tobacco curing and similar applications.
Contact Ratings (120 Vac): 8.0 AFL, 48.0 ALR
1 Contact Ratings (240 Vac): 5.1 AFL, 30.6 ALR
Voltage: 120 Vac or 240 Vac
Frequency: 50 Hz; 60 Hz

Hydronic Controls
4-7/16 (113)

2-1/4 (57) Approvals:


2 (51)
2-1/8 (54) Canadian Standards Association: Listed
3/8 (10)
Underwriters Laboratories, Inc. Component Recognized

5-5/8 2
4-3/16 2 (143)
(106)

Controls
Water
15/16
(24)

Building Automation
1 TOP KNOCKOUT IS 7/8 FOR
1-7/32 ALL BUT T6031H ENCLOSED.
3/8 (31)
(10) 2 T678 C,E,F DO NOT HAVE
EXTERNAL KNOB.
M7523A

Setpoint Maximum
Temperature Operating Differential Capillary
Range Temperature Temperature Bulb Size Length
Product Sensor
Number (F) (C) (F) (C) (F) (C) Element (inch) (mm) (ft) (m) Output Includes Comments

Components
T4031C1012 40 F to 4 C to 205 F 96 C 5F 2.8 C Copper 2 7/8 in. long x 73 mm long x 5.5 ft 1.7 m 1 SPST Break on

Commercial
180 F 82 C 3/8 in. diameter 10 mm diameter temperature rise
* T6031C1009 40 F to 4 C to 205 F 96 C 2F 1.1 C Copper 3/8 in. diameter x 10 mm diameter 5.5 ft 1.7 m 1 SPDT 107324A —
180 F 82 C bulb 2 7/8 in. long x 73 mm long Duct Bulb
holder
T6031C1058 100 F to 38 C to 265 F 130 C 2F 1.1 C Stainless 3/8 in. diameter x 10 mm diameter 5 ft 1.5 m 1 SPDT —
240 F 116 C steel bulb 2 7/8 in. long x 73 mm long
T6031D1015 40 to 4 C to — — 5F 2.8 C Copper 3/8 in. diameter x 10 mm diameter 5.5 ft 1.7 m 1 SPDT —
Pneumatic Controls

180 F 82 C bulb 2 7/8 in. long x 73 mm long


T6031D1031 0 F to -18 C to 170 F 77 C 5F 2.8 C Copper 3/8 in. diameter x 10 mm diameter 5.5 ft 1.7 m 1 SPDT —
70 F +21 C bulb 2 7/8 in. long x 73 mm long
T6031D1049 30 F to -1 C to 305 F 152 C 7F 3.9 C Copper 3/8 in. diameter x 10 mm diameter 5.5 ft 1.7 m 1 SPDT —
270 F +132 C bulb 2 7/8 in. long x 73 mm long
T6031F1010 55 F to 13 C to 150 F 66 C 1.5 F 0.8 C Copper 5/16 in. diameter 8 mm diameter x 5.5 ft 1.7 m 1 SPDT Does not include
90 F 32 C bulb x 11 11/16 in. long 297 mm long enclosure
* TRADELINE models • SUPER TRADELINE models
Industrial Combustion
Controls

70-6910 365
Temperature Controllers
T6031E Unit Thermostat
Ambient temperature compensated, high-limit controllers for
agriculture and industrial applications.
• Suitable for line-voltage, low voltage, or millivolt (Powerpile) control
of bulk milk tanks, beverage dispensing machines, ice cube
machines, dishwashers, crop drying, tobacco curing, and similar
applications.
• Enclosed snap action switches available with SPST or SPDT action.
• Models available that make or break on temperature rise.
• Screwdriver adjustment for temperature setting; external knob
option.
• Immersion well not included.

Dimensions in inches (millimeters) Type: Remote bulb


Application: Remote bulb temperature control
Bulb Size: 5/16 in. diameter x 11 11/16 in. long
15/16 (8 mm diameter x 297 mm long)
KNOCKOUT FOR Capillary Length: 5.5 ft (1.7 m)
(24)
1/2 CONDUIT (BOTH ENDS)
Sensor Element: Copper bulb
Color: Gray
Contact Ratings (120 Vac): 3.2 AFL, 19.2 ALR
Contact Ratings (240 Vac): 1.6 AFL, 9.6 ALR
4-7/16 (113)
Voltage: 120 Vac or 240 Vac
2-1/4 (57) Frequency: 60 Hz; 50 Hz
2 (51) Maximum Operating Temperature: 150 F (66 C)
2-1/8 (54)
3/8 (10)
Approvals:
Canadian Standards Association: Listed
Underwriters Laboratories, Inc. Component Listed

5-5/8 1
4-3/16 2 (143)
(106)

15/16
(24)

1 ALL MODELS DO NOT


1-7/32
HAVE EXTERNAL KNOB
3/8 (31)
(10) M13909

Differential
Setting Temperature Range Temperature
Product Number (F) (C) (F) (C) Output Output Type Number of Sensor Inputs
T6031E1004 55 F to 90 F 13 C to 32 C 1.5 F 0.8 C 1 SPDT relay 1

366 customer.honeywell.com 70-6910


Temperature Controllers
T4054 Return Air Controller

Controls
Home
Provides SPDT heavy-duty, line-voltage temperature control in
ventilation, heating or cooling systems.
• Use in a variety of farm, industrial or commercial applications.
• Wall or duct mount in any position.
• Fast response, tin-plated element not affected by adverse
environment.
• Rugged case.

Indoor Air Quality


• Mounts on flat surface with three screws.
• T6064 provides fast response with hydraulic temperature sensing
elements mounted on the unit.

Combustion Controls
Type: Filled element Maximum Operating Temperature: 125 F (52 C)

Residential
Application: Provides control in heating systems Contact Ratings (120 Vac): 16.0 AFL, 96.0 ALR
Dimensions, Approximate: 7 5/8 in. high x 2 5/8 in. wide x 2 in. deep Contact Ratings (240 Vac): 8.0 AFL, 48.0 ALR
(194 mm high x 67 mm wide x 51 mm deep) Approvals:
Accuracy: ±6 F (±3.3 C) Canadian Standards Association: CSA Listed: Report -1
Sensor Element: Fast response capillary Underwriters Laboratories, Inc. Listed: E4436, vol. 5, sec. 12, Guide
Color: Gray XAPX
Voltage: 120 Vac or 240 Vac
Frequency: 60 Hz; 50 Hz

Hydronic Controls
Setting Temperature Differential
Range Temperature Number of
Output Sensor
Product Number (F) (C) (F) (C) Output Type Inputs Comments
T4054A1000 36 F to 100 F 2 C to 38 C 3.5 F 1.9 C 1 SPST relay 1 Make R to B on temperature fall
T4054B1016 36 F to 100 F 2 C to 38 C 3.5 F 1.9 C 1 SPST relay 1 Make R to W on temperature rise

Controls
Water
Building Automation
Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 367
Temperature Controllers
T6054 Utility Line Voltage Thermostat
Provides SPDT heavy-duty, line-voltage temperature control in
ventilation, heating or cooling systems.
• Use in a variety of farm, industrial or commercial applications.
• Wall or duct mount in any position.
• Fast response, tin-plated element not affected by adverse
environment.
• Rugged case.
• Mounts on flat surface with three screws.

Dimensions in inches (millimeters) Type: Filled element


Application: Provides control in ventilation, heating, cooling or heating-
1-1/2 cooling systems
(38) Accuracy: ±10 F (±5.6 C)
Sensor Element: Copper filled element
Color: Gray
Contact Ratings (120 Vac): 7.4 AFL, 44.4 ALR
Contact Ratings (240 Vac): 3.7 AFL, 22.2 ALR
7-1/8 Voltage: 120 Vac or 240 Vac
(181) Frequency: 60 Hz; 50 Hz
Maximum Operating Temperature: 125 F (52 C)

5-5/8
Approvals:
4-3/16
(143) Canadian Standards Association: CSA Listed: Report -1
(106)
Underwriters Laboratories, Inc. Listed: E4436, vol. 5, sec. 12, Guide
XAPX

2 -1/8
1-1/4
(54)
(32)
2 (51)

1 (25)

M27438

Differential
Setting Temperature Range Temperature
Number of
Product Number (F) (C) (F) (C) Output Output Type Sensor Inputs Includes
* T6054A1005 -30 F to +110 F -34 C to +43 C 3.5 F 1.9 C 1 SPDT relay 1 Case
* TRADELINE models • SUPER TRADELINE models

368 customer.honeywell.com 70-6910


Temperature Controllers
T631A,B,C Farm Controllers

Controls
Home
Provide line voltage control of heating, cooling and ventilating
systems in farm buildings or storage areas.
• Use in barns, poultry houses, hog barns, pump houses, milk houses
and crop storage houses.
• Treated to resist corrosion.
• Slots in front and bottom of case provide maximum air circulation
over the coiled sensing element.

Indoor Air Quality


• SPDT snap switches permanently sealed against corrosion.
• Easy mounting using screws through holes in back of case.

Dimensions in inches (millimeters) Type: Agricultural Temperature Controller


Application: Provide line voltage control of heating, cooling and
CASE WITH 3/16 (5) MOUNTING HOLES [4] ventilating systems in farm buildings or storage areas
COVER Sensor Element: Coiled Copper Tube
KNOCKOUT FOR 2-7/8

Combustion Controls
REMOVED
1/2 (13) CONDUIT [3] (73) MAX. Color: Red finish
7/8
15/16
Approvals:

Residential
(22) 4-15/32 (114) (24)
Canadian Standards Association: Certified: File No. LR1620, Guide
No. 400-E-O
1-1/16 3-1/4
1 1-5/32
Underwriters Laboratories, Inc. File No. E4436 Vol.1 Sec. UL Guide
(27) (83)
4-5/16 (29) XAPX
3-5/16 (110)
(84) MAX.

Hydronic Controls
1-3/16 13/32
4-15/32 (114)
7/16 (30) (10)
(11) 6-1/16 (154) STANDARD
SWITCH BOX
1 KNOCKOUT ON EACH END. M27435

Setpoint Maximum Interstage


Temperature Operating Differential Differential
Range Temperature Temperature Temperature Contact Ratings
Product Number (F) (C) (F) (C) (F) (C) (F) (C) Output Voltage (24 Vac) (120 Vac) (240 Vac)
T631A1006 35 F to — 120 F 49 C 2F 1.1 C — — 1 SPDT 24 Vac or 2.0A AFL 7.4 AFL, 3.7 AFL,

Controls
Water
100 F 120/240 Vac 44.4 ALR 22.2 ALR
T631A1022 70 F to — 150 F 67 C 2F 1.1 C — — 1 SPDT 24 Vac or 2.0A AFL 7.4 AFL, 3.7 AFL,
140 F 120/240 Vac 44.4 ALR 22.2 ALR
T631A1030 0 F to 70 — 125 F 52 C 3F 1.7 C — — 1 SPDT 24 Vac or 2.0A AFL 7.4 AFL, 3.7 AFL,
F 120/240 Vac 44.4 ALR 22.2 ALR
T631A1063 -10 F to — 125 F 52 C 3F 1.7 C — — 1 SPDT 24 Vac or 2.0A AFL 7.4 AFL, 3.7 AFL,

Building Automation
+100 F 120/240 Vac 44.4 ALR 22.2 ALR
T631A1113 35 F to — 120 F 50 C 3.5 F 1.9 C — — 1 SPDT 120 Vac or — 16.0 AFL, 8.0 AFL,
100 F (1 hp at 240 Vac 96.0 ALR 48.0 ALR
0.7 kW)
T631A1154 — 0 C to 120 F 50 C 2F 1.1 C — — 1 SPDT 24 Vac or 2.0A AFL 7.4 AFL, 3.7 AFL,
40 C 120/240 Vac 44.4 ALR 22.2 ALR
T631B1005 35 F to — 120 F 50 C 2F 1.1 C 3.5 F 1.9 C 2 SPDT 120 Vac or 2.0A AFL 7.4 AFL, 3.7 AFL,
100 F 240 Vac 44.4 ALR 22.2 ALR
T631B1054 35 F to — 120 F 50 C 2F 1.1 C 0 F to 0 C to 2 SPDT 120 Vac or — 16.0 AFL, 8.0 AFL,
100 F 7F 4C (1 hp at 240 Vac 96.0 ALR 48.0 ALR

Components
Commercial
adj. adj. 0.7 kW)
T631C1012 20 F to — 125 F 52 C 3F 1.7 C — — 1 SPDT 120 Vac or — 16.0 AFL, 8.0 AFL,
90 F (1 hp at 240 Vac 96.0 ALR 48.0 ALR
0.7 kW)
T631C1020 70 F to — 150 F 67 C 2F 1.1 C — — 1 SPDT 24 Vac or 2.0A AFL 7.4 AFL, 3.7 AFL,
140 F 120/240 Vac 44.4 ALR 22.2 ALR
T631C1038 — -10 C to 125 F 52 C 3F 1.7 C — — 1 SPDT 24 Vac or 2.0A AFL 7.4 AFL, 3.7 AFL,
Pneumatic Controls

+30 C 120/240 Vac 44.4 ALR 22.2 ALR


T631C1046 — 20 C to 150 F 67 C 2F 1.1 C — — 1 SPDT 24 Vac or 2.0A AFL 7.4 AFL, 3.7 AFL,
60 C 120/240 Vac 44.4 ALR 22.2 ALR
T631C1053 35 F to — 120 F 49 C 2F 1.1 C — — 1 SPDT 120 Vac or 2.0A AFL 7.4 AFL, 3.7 AFL,
100 F 240 Vac 44.4 ALR 22.2 ALR
* T631C1103 -30 F to — 125 F 52 C 5F 2.8 C — — 1 SPDT 24 Vac or — 16.0 AFL, 8.0 AFL,
+100 F (1 hp at 120/240 Vac 96.0 ALR 48.0 ALR
0.7 kW)
Industrial Combustion

* TRADELINE models • SUPER TRADELINE models


Controls

70-6910 369
Temperature Controllers
T631F,G NEMA IV Controllers
Provide line voltage control of heating, cooling and ventilating
systems in farm buildings, storage areas and industrial
environments; watertight, dust-proof enclosure.
• Use in barns, brooder houses, poultry houses, hog barns, pump
houses, milk houses, crop storage houses and industrial
environments. NEMA 4X enclosure protects thermostat and wiring
connections from oil, water, dust, and corrosion.
• Clear plastic cover reveals setpoint, discourages tampering.
• Sensing element externally mounted for fast response and tin plated
to resist corrosion.
• Reliable snap switches sealed against contamination.
• Insulated case has internal grounding screw for safety.
• Meet National Electrical Code Article 547-4 requirements.
• Easy mounting with screws through holes in flanges on case.

Dimensions in inches (millimeters) Type: Agricultural Temperature Controller


Application: Provide line voltage control of heating, cooling and
7 (178) ventilating systems in farm buildings or storage areas
4-13/16 (122) Dimensions, Approximate: 5 in. high x 6 1/2 in. wide x 3 in. deep (127
mm high x 165 mm wide x 76 mm deep)
Sensor Element: Coiled, Tin-plated Copper Tube
Color: Gray finish
5 Frequency: 60 Hz; 50 Hz
(127) Maximum Operating Temperature: 145 F
Setpoint Temperature Range: 35 F to 100 F
4-5/8 Differential Temperature: 2 F (1.1 C)
(117)
Approvals:
4-1/4 Canadian Standards Association: Certified: File No. LR1620, Guide
(108) No. 400-E-O
Underwriters Laboratories, Inc. File No. E4436 Vol.1 Sec. UL Guide
XAPX

1/4 (6) 7/32 (6) DIA. [6] Contact Ratings


3/16 1-1/8 (29)
(5) 2-1/4 (57)
(24 Vac) (120 Vac) (240 Vac)
FRONT VIEW T631F1068 2.0A AFL 7.4 AFL, 44.4 ALR 3.7 AFL, 22.2 ALR

1-1/8 (29) STANDARD KNOCKOUT T631F1084 2.0A AFL 7.4 AFL, 44.4 ALR 3.7 AFL, 22.2 ALR
7/8 (22) STANDARD T631F1092 — 16.0 AFL, 96.0 ALR 8.0 AFL, 48.0 ALR
KNOCKOUT
T631G1059 — 16.0 AFL, 96.0 ALR 8.0 AFL, 48.0 ALR
3-13/16
(97)
3
(76)

1-3/16
(30)

1-11/16 (43)
1/4 (6) DIA. (REF.)
BOTTOM VIEW M27436

Setpoint Interstage
Temperature Differential
Range Temperature Contact Ratings
Product Number (F) (F) Voltage Output (24 Vac) (120 Vac) (240 Vac) Comments
T631F1068 35 F to 100 F 0 F to 7 F 24 Vac or 120/240 1 SPDT 2.0A AFL 7.4 AFL, 3.7 AFL, Internal Setpoint
adjustable Vac 44.4 ALR 22.2 ALR Adjustment
T631F1084 35 F to 100 F 0 F to 7 F 24 Vac or 120/240 1 SPDT 2.0A AFL 7.4 AFL, 3.7 AFL, External Setpoint
adjustable Vac 44.4 ALR 22.2 ALR Adjustment
T631F1092 35 F to 100 F 0 F to 7 F 120 Vac or 240 1 SPDT (1 hp) — 16.0 AFL, 8.0 AFL, External Setpoint
adjustable Vac 96.0 ALR 48.0 ALR Adjustment
T631G1059 35 F to 100 F 0 F to 7 F 120 Vac or 240 2 SPDT (1 hp) — 16.0 AFL, 8.0 AFL, External Setpoint
adjustable Vac 96.0 ALR 48.0 ALR Adjustment

370 customer.honeywell.com 70-6910


Temperature Controllers
T675A,B; T678A Remote Bulb Controllers

Controls
Home
Remote bulb thermostats regulate temperature of air or liquids in
ducts, pipes, tanks and boilers.
• Suitable for applications requiring temperature control of air or
liquids where controller must be placed outside the sensing area.
• Typical uses include control of dampers and valves in heating,
cooling and heating-cooling systems.
• Fast response models (available for use in return air duct) operate

Indoor Air Quality


approximately four times faster than standard models.
• Controller can be mounted in any position. Ambient temperature
compensation provides good temperature control.
• Refer to T775 Electronic Remote Temperature Controller where
more exact control is required and/or remote controller location is
preferred.
• T678 models have a maximum connected load of 2000 VA.

Combustion Controls
Residential
Dimensions in inches (millimeters) Type: Remote bulb
Application: Regulates temperature of air or liquids in ducts, pipes,
tanks and boilers
3
Voltage: 120 Vac or 240/277 Vac
2 (51)
Frequency: 60 Hz; 50 Hz
7/8 (22) DIA KNOCKOUT Output Type: Relay
(BOTH ENDS)
15/16 (24) Number of Sensor Inputs: 1

Hydronic Controls
Approvals:
2-5/8 (67) Canadian Standards Association: CSA Listed: Report -1
2-1/4 (57)
Underwriters Laboratories, Inc. UL Listed: E4436, Vol. 4, Sec. 11,
2-1/8 (54)
Guide XAPX
3

Contact Ratings
1-3/4 (120 Vac) (240 Vac) (277 Vac)
(45)
1 T675A with Adjustable 8.0 AFL, 5.1 AFL, 4.2 AFL,
Differential Temperature 48.0 ALR 30.6 ALR 25.2 ALR

Controls
T675A, B with Fixed 125 VA 125 VA 125 VA

Water
5-5/8 Differential Temperature
21/32 (143)
(17) DIA T675B 125 VA 125 VA 125 VA
4-3/16 3
(106) 7/32 (6) T678A 8.0 AFL, 5.1 AFL, 4.2 AFL,
2
DIA [3] 48.0 ALR 30.6 ALR 25.2 ALR

Building Automation
1-15/16
(49)
11/16
(18)
13/64
1-7/32 (5) [3]
3/32 (2)
(31) 3/8 (10)
3/8
(10) DIA [3] 2-7/16 (62)

1 T675B DOES NOT HAVE AN ADJUSTMENT KNOB.

2 T675B HAS A MANUAL RESET BUTTON (INDICATED BY DASHED LINES).

Components
Commercial
3 TRADELINE MODELS T675A, T678A ONLY – NOREL COVER
INCREASES THESE DIMENSIONS BY APPROXIMATELY 1/8 IN. (3).
M23928

Setpoint Maximum Interstage


Temperature Operating Differential Differential Capillary
Range Temperature Temperature Temperature Bulb Size Length
Product Sensor
Number (F) (C) (F) (C) (F) (C) (F) (C) (inch) (mm) (ft) (m) Output Element Includes Comments
Pneumatic Controls

T675A1045 0 F to -18 C to 125 F 52 C 3 F to 1.7 C to — — 1/2 in. x 13 mm dia. x 20 ft. 6.1 m 1 SPDT Stainless Stainless Steel
100 F +38 C 10 F 5.6 C 4 3/16 in. 106 mm long steel bulb Bulb
T675A1102 160 F to 71 C to 280 F 138 C 3 F to 1.7 C to — — 1/2 in. x 13 mm dia. x 20 ft. 6.1 m 1 SPDT Copper —
260 F 127 C 10 F 5.6 C 4 3/16 in. 106 mm long bulb
T675A1136 0 F to -18 C to 125 F 52 C 1F 0.6 C — — 1/2 in. x 13 mm dia. x 20 ft. 6.1 m 1 SPDT Copper —
100 F +38 C fixed fixed 4 3/16 in. 106 mm long bulb
T675A1243 167 F to 75 C to 125 F 52 C 3 F to 1.7 C to — — 1/2 in. x 13 mm dia. x 5 ft 1.5 m 1 SPDT Copper Celsius model
257 F 125 C 10 F 5.6 C 4 3/16 in. 106 mm long bulb
Industrial Combustion

T675A1425 55 F to 13 C to 200 F 93 C 3.6 F to 2 C to — — 1/2 in. x 13 mm x 90 20 ft. 6.1 m 1 SPDT Copper —


175 F 79 C 12 F 6.7 C 3 9/16 in. mm bulb
Controls

* TRADELINE models • SUPER TRADELINE models

70-6910 371
Temperature Controllers
Setpoint Maximum Interstage
Temperature Operating Differential Differential Capillary
Range Temperature Temperature Temperature Bulb Size Length
Product Sensor
Number (F) (C) (F) (C) (F) (C) (F) (C) (inch) (mm) (ft) (m) Output Element Includes Comments
— T675A1458 55 F to 13 C to 125 F 52 C 1F 0.6 C — — 1/2 in. x 13 mm x 90 5 ft 1.5 m 1 SPDT Copper —
175 F 79 C fixed fixed 3 9/16 in. mm bulb
* T675A1508 0 F to -18 C to 200 F 93 C 3 F to 1.7 C to — — 1/2 in. x 13 mm dia. x 5 ft 1.5 m 1 SPDT Copper 107324A Includes
100 F +38 C 10 F 5.6 C 4 3/16 in. 106 mm long bulb Duct Bulb 107324A Duct
holder Bulb Holder
* T675A1516 0 F to -18 C to 280 F 138 C 1 F 0.6 C — — 1/2 in. x 13 mm dia. x 5 ft 1.5 m 1 SPDT Copper 107324A Includes
100 F +38 C fixed fixed 4 3/16 in. 106 mm long bulb Duct Bulb 107324A Duct
holder Bulb Holder
— T675A1524 55 F to 13 C to 200 F 93 C 1F 0.6 C — — 1/2 in. x 13 mm x 90 20 ft. 6.1 m 1 SPDT Copper —
175 F 79 C fixed fixed 3 9/16 in. mm bulb
* T675A1532 160 F to 71 C to 125 F 52 C 3 F to 1.7 C to — — 1/2 in. x 13 mm dia. x 5 ft 1.5 m 1 SPDT Copper 107324A Includes
260 F 127 C 10 F 5.6 C 4 3/16 in. 106 mm long bulb Duct Bulb 107324A Duct
holder Bulb Holder
* T675A1540 55 F to 13 C to 125 F 52 C 3.6 F to 2 C to — — 1/2 in. x 13 mm x 90 5 ft 1.5 m 1 SPDT Copper 107324A Includes
175 F 79 C 12 F 6.7 C 3 9/16 in. mm bulb Duct Bulb 107324A Duct
holder Bulb Holder
* T675A1565 0 F to -18 C to 200 F 93 C 3 F to 1.7 C to — — 1/2 in. x 13 mm x 90 20 ft. 6.1 m 1 SPDT Copper 107324A Includes
100 F +38 C 10 F 5.6 C 4 3/16 in. mm bulb Duct Bulb 107324A Duct
holder Bulb Holder
* T675A1706 0 F to -18 C to 125 F 52 C 3 F to 1.7 C to — — coil 1 1/2 coil 38.1 mm 5 ft 1.5 m 1 SPDT Fast 131524A Fast response
100 F +38 C 10 F 5.6 C in. x 127 mm response duct bulb model, includes
diameter capillary holder 107324A Duct
x 5 in. Bulb Holder
— T675A1771 55 F to 13 C to 125 F 52 C 1F 0.6 C — — coil 1 1/2 coil 38.1 mm 5 ft 1.5 m 1 SPDT Fast 131524A Fast response
175 F 79 C fixed fixed in. x 127 mm response duct bulb model, includes
diameter capillary holder 107324A Duct
x 5 in. Bulb Holder
— T675B1002 30 F to -1 C to 125 F 52 C Manual Manual — — 1/2 in. x 13 mm dia. x 10 ft 3m 1 SPDT Copper —
50 F +10 C Reset Reset 4 3/16 in. 106 mm long bulb
— T675B1010 30 F to -1 C to 125 F 52 C Manual Manual — — 1/2 in. x 13 mm dia. x 20 ft. 6.1 m 1 SPDT Copper —
50 F +10 C Reset Reset 4 3/16 in. 106 mm long bulb
— T675B1028 -20 F to -29 C to 200 F 93 C Manual Manual — — 1/2 in. x 13 mm dia. x 10 ft 3m 1 SPDT Copper —
+50 F +10 C Reset Reset 4 3/16 in. 106 mm long bulb
— T678A1015 0 F to -18 C to 125 F 52 C 3F 1.7 C 3 F to 1.7 C to 1/2 in. x 13 mm dia. x 20 ft. 6.1 m 2 SPDT Copper maximum
100 F +38 C fixed fixed 10 F 5.6 C 4 3/16 in. 106 mm long switch bulb connected load =
adj. adj. contacts 2000VA
— T678A1163 5 F to -15 C to 200 F 93 C 3F 1.7 C 3 F to 1.7 C to 1/2 in. x 13 mm dia. x 20 ft. 6.1 m 2 SPDT Copper maximum
95 F +35 C fixed fixed 10 F 5.6 C 4 3/16 in. 106 mm long switch bulb connected load =
adj. adj. contacts 2000VA;
Celsius model
— T678A1361 55 F to 13 C to 125 F 52 C 3.6 F 2.0 C 3.6 F to 2.0 C to 1/2 in. x 13 mm x 90 20 ft. 6.1 m 2 SPDT Copper maximum
175 F 79 C fixed fixed 12 F 6.7 C 3 9/16 in. mm switch bulb connected load =
adj. adj. contacts 2000VA
* T678A1437 0 F to -18 C to 200 F 93 C 3F 1.7 C 3 F to 1.7 C to 1/2 in. x 13 mm dia. x 5 ft 1.5 m 2 SPDT Copper maximum
100 F +38 C fixed fixed 10 F 5.6 C 4 3/16 in. 106 mm long switch bulb connected load =
adj. adj. contacts 2000VA
* T678A1445 55 F to 13 C to 125 F 52 C 3.6 F 2.0 C 3.6 F to 2.0 C to 1/2 in. x 13 mm x 90 5 ft 1.5 m 2 SPDT Copper maximum
175 F 79 C fixed fixed 12 F 6.7 C 3 9/16 in. mm switch bulb connected load =
adj. adj. contacts 2000VA
* T678A1478 0 F to -18 C to 200 F 93 C 3F 1.7 C 3 F to 1.7 C to 1/2 in. x 13 mm dia. x 5 ft 1.5 m 2 SPDT Fast maximum
100 F +38 C fixed fixed 10 F 5.6 C 4 3/16 in. 106 mm long switch response connected load =
adj. adj. contacts capillary 2000VA; Fast
response model
* T678A1494 55 F to 13 C to 3.6 F 2.0 C 3.6 F to 2.0 C to 1/2 in. x 13 mm x 90 5 ft 1.5 m 2 SPDT Fast maximum
175 F 79 C fixed fixed 12 F 6.7 C 3 9/16 in. mm switch response connected load =
adj. adj. contacts capillary 2000VA; Fast
response model
— T678A1627 0 F to -18 C to 3.6 F 2.0 C 3.6 F to 2.0 C to 1/2 in. x 13 mm dia. x 10 ft 3m 2 SPDT Averaging maximum
100 F +38 C fixed fixed 12 F 6.7 C 4 3/16 in. 106 mm long switch capillary connected load =
adj. adj. contacts 2000VA
* T678A1692 — 15 C to 125 F 52 C 3.6 F 2.0 C 3.6 F to 2.0 C to 1/2 in. x 13 mm 5 ft 1.5 m 2 SPDT Copper maximum
75 C 12 F 6.7 C 4 in. diameter x switch bulb connected load =
102 mm long contacts 2000VA;
Celsius model
* TRADELINE models • SUPER TRADELINE models

372 customer.honeywell.com 70-6910


Temperature Controllers
T675F Crop-Trol Controller

Controls
Home
Used to control an oil burning, portable crop dryer.
• Suitable for line-voltage, low-voltage or millivolt (Powerpile)
switching.
• Mounts directly on dryer with sensing bulb in discharge air duct.
• Knob extends through case for manual control point adjustment.
• Differential setting wheel, located under cover, adjusts difference
between cut-in and cut-out temperatures.

Indoor Air Quality


Combustion Controls
Residential
Dimensions in inches (millimeters) Type: Remote bulb
Application: Crop-trol, provides control of portable crop drying

Hydronic Controls
equipment.
Bulb Size: 3/8 in. x 3 in. (10 mm x 76 mm)
Sensor Element: Copper bulb
7/8 (22) DIA KNOCKOUT 2-1/8 Contact Ratings (120 Vac): 8.0 AFL, 48.0 ALR
(BOTH ENDS) (54) Contact Ratings (240 Vac): 5.1 AFL, 30.6 ALR
Contact Ratings (277 Vac): 4.2 AFL, 25.2 ALR
2-19/32 Voltage: 120 Vac or 240/277 Vac
(66)
15/16 (24) Frequency: 60 Hz; 50 Hz
Maximum Operating Temperature: 245 F (118 C)
2 (51) Setpoint Temperature Range: 80 F to 220 F (27 C to 104 C)
Differential Temperature: 5 F to 30 F (2.8 C to 17 C)

Controls
Water
Approvals:
Underwriters Laboratories, Inc. Component Listed

5-5/8
(143)

Building Automation
MOUTING HOLES
LOCATED IN
BACK OF CASE
4-3/16
(106)

11/16

Components
(18)

Commercial
1-1/4
(32) M23927

Bulb Size Capillary Length


Product Number (inch) (mm) (ft) (m) Output Output Type Number of Sensor Inputs
T675F1032 3/8 in. x 3 in. 10 mm x 76 mm 10 ft 3m 1 SPDT relay 1
Pneumatic Controls
Industrial Combustion
Controls

70-6910 373
Temperature Controllers
T678C,E,F Changeover Temperature Controller
Remote bulb thermostats regulate temperature of air or liquids in
ducts, pipes, tanks and boilers.
• Suitable for applications requiring temperature control of air or
liquids where controller must be placed outside the sensing area.
• Typical uses include control of dampers and valves in heating,
cooling and heating-cooling systems.
• Fast response models (available for use in return air duct) operate
approximately four times faster than standard models.
• Controller can be mounted in any position. Ambient temperature
compensation provides good temperature control.
• Refer to T775 Electronic Remote Temperature Controller where
more exact control is required and/or remote controller location is
preferred.
• T678 models have a maximum connected load of 2000 VA.

Dimensions in inches (millimeters) Type: Remote bulb


Application: Changeover temperature control
Dimensions, Approximate: 5 5/8 in. high x 2 in. wide x 2 5/8 in. deep
15/16 (143 mm high x 51 mm wide x 67 mm deep)
KNOCKOUT FOR Bulb Size: 3/8 in. x 3 in. (10 mm x 76 mm)
(24)
1/2 CONDUIT (BOTH ENDS)
Sensor Element: Copper bulb
1 Voltage: 120 Vac or 240 Vac
Frequency: 60 Hz; 50 Hz
Output: 2 SPDT switch contacts
Output Type: relay
2-1/4 (57)
2 (51)
3/8 (10) 2-1/8 (54) Contact Ratings
(120 Vac) (240 Vac)
T678C 8.0 AFL, 48.0 ALR 5.1 AFL, 30.6 ALR
T678E Control: 2.6 AFL, 15.6 ALR; Control: 1.3 AFL, 7.8 ALR;
Hi Limit: 7.4 AFL, 44.4 ALR Hi Limit: 5.1 AFL, 30.6 ALR
70

5-5/8
80
60

4-3/16 (143)
(106) T678F 8.0 AFL, 48.0 ALR 5.1 AFL, 30.6 ALR

15/16
(24)

1-7/32 M13907
3/8 (31)
(10)

Setpoint Maximum Interstage


Temperature Operating Differential Differential Capillary
Range Temperature Temperature Temperature Bulb Size Length Number of
Sensor
Product Number (F) (C) (F) (C) (F) (C) (F) (C) (inch) (mm) (ft) (m) Inputs
T678C1005 55 F to 13 C to 205 F 96 C 5F 2.8 C — — 3/8 in. x 10 mm x 5.5 ft 1.7 m 1
85 F 29 C 3 in. 76 mm
T678E1003 40 F to 4 C to 210 F 99 C 2F 1.1 C 7F 3.9 C 1/8 in. x 3 mm x 17 ft. 5.2 m 1
180 F 82 C 42 in. 1064 m
T678F1002 55 F to 13 C to 130 F 54 C 2F 1.1 C — — 5/16 in. x 8 mm x 5.5 ft 1.7 m 1
85 F 29 C 11 11/16 in. 297 mm

374 customer.honeywell.com 70-6910


Temperature Controllers
T7079 Solid State Remote Temperature Controller

Controls
Home
The T7079 Electronic Remote Sensor Temperature Controller is
capable of providing on-off temperature control for ducts, tanks,
heating and refrigeration units, greenhouses, animal confinement
buildings and other applications where electronic accuracy in
addition to remote sensing is desired.
• Switch selection of heat or cool mode.
• Temperature sensing up to 400 feet.

Indoor Air Quality


• Does not require field calibration.
• 10K NTC temperature sensor.
• Wide setpoint temperature range.
• LED annunciation for both power on and relay state.
• Dual setpoint scale (F and C). Isolation transformer for 24 Vac input.
• Single- or Dual-stage output.
• Dual-stage output models can be configured as two-heat, two-cool,
or one-heat/one-cool.

Combustion Controls
Residential
Dimensions in inches (millimeters) Application: Heat or Cool
Accuracy: ±2 F (±3.6 C)
2 (50) 2-7/16 (61) Maximum distance to sensor: 400 ft (122 m)
1 (25) 2 (50) 2-7/16 (61) Contact Ratings (120 Vac): 9.8 AFL, 58.8 ALR, 125 VA Pilot Duty
Contact Ratings (240 Vac): 4.9 AFL, 29.4 ALR, 125 VA Pilot Duty
Frequency: 50 Hz; 60 Hz

Hydronic Controls
STAGE1 STAGE2 POWER Operating Temperature Range: -40 F to +140 F (-40 C to +60 C)
Setpoint Temperature Range: -25 F to +105 F (-32 C to +40 C)
Throttling Range: 1 F to 30 F (-17 C to +1 C)
Number of Sensor Inputs: 1
Approvals:
Underwriters Laboratories, Inc. Component Listed
7-3/16
4-1/2 (183) Accessories
(114) 107324A Capillary Holder Assembly for duct insertion, 8 3/8 in. long
121371A Copper. Bulb size: 3/8 in. x 3 in. (10 mm x 76 mm). Well size:
3 in. (76 mm) insertion, 1 1/2 in. NPT. Includes mounting clamp

Controls
121371E Stainless steel. Bulb size: 3/8 in. x 3 in. (10 mm x 76 mm).

Water
Well size: 3 in. (76 mm) insertion, 1 1/2 in. (38 mm) insulation, 1/2 in.
(13 mm) NPT. Includes mounting clamp.
32004800-001 10K sensor for use with T7079
M17560
T7047C1090 Wall Mounted Remote Bulb Enclosure for T775 or T7079
remote sensing bulb.

Building Automation
Setpoint
Temperature
Range
Output
Product Number Description (F) (C) Voltage Type Sensor Element Sensors Included
T7079A1004 Heat or Cool Controller -25 F to -32 C to 24 Vac 1 SPDT 10k @ 25 C NTC 10K ohm NTC Sensor
+105 F +40 C sensing element (32004800-001)
T7079A1012 Heat or Cool Controller 100 F to 38 C to 24 Vac 1 SPDT 10k @ 25 C NTC 10K ohm NTC Sensor
240 F 116 C sensing element (32004800-001)
T7079A1046 Heat or Cool Controller -25 F to -32 C to 120 Vac or 1 SPDT 10k @ 25 C NTC 10K ohm NTC Sensor

Components
+105 F +40 C 230 V sensing element (32004800-001)

Commercial
T7079A1053 Heat or Cool Controller 100 F to 38 C to 120 Vac or 1 SPDT 10k @ 25 C NTC 10K ohm NTC Sensor
240 F 116 C 230 V sensing element (32004800-001)
T7079B1028 1 Heat and 1 Cool or -25 F to -32 C to 24 Vac 2 SPDT 10k @ 25 C NTC 10K ohm NTC Sensor
2 Heat and 2 Cool Controller, +105 F +40 C sensing element (32004800-001)
T7079B1036 1 Heat and 1 Cool or 100 F to 38 C to 24 Vac 2 SPDT 10k @ 25 C NTC 10K ohm NTC Sensor
2 Heat and 2 Cool Controller 240 F 116 C sensing element (32004800-001)
Pneumatic Controls

T7079B1044 1 Heat and 1 Cool or -25 F to -32 C to 120 Vac or 2 SPDT 10k @ 25 C NTC 10K ohm NTC Sensor
2 Heat and 2 Cool Controller +105 F +40 C 230 V sensing element (32004800-001)
T7079B1051 1 Heat and 1 Cool or 100 F to 38 C to 120 Vac or 2 SPDT 10k @ 25 C NTC 10K ohm NTC Sensor
2 Heat and 2 Cool Controller 240 F 116 C 230 V sensing element (32004800-001)
* TRADELINE models • SUPER TRADELINE models
Industrial Combustion
Controls

70-6910 375
Temperature Controllers
T775 Series 2000 Stand-Alone Controllers
The T775 electronic remote temperature controllers are the next
generation of commercial and agricultural controls capable of
remote sensing of temperature and providing switched and/or
proportional outputs to various types of loads.
• Save time on installations with the easy-to-use graphical Interface,
large display, and the intuitive programming.
• Use the time clock scheduler or digital input to control the setback
and disable output options to help save energy.
• Protect equipment from freezing or overheating on models with the
modulating high or low limit control option.
• Get pinpoint control on modulating outputs by setting the integral
and derivative times (PI or PID).
• Configure models with reset in a few easy steps.
• Control floating actuators with floating outputs on select models.
• Eliminate the need for a separate time delay device and protect
equipment with the minimum off time option.
• Sensor 50021579-001 included with non-NEMA 4X models.
• Sensor T775-SENS-WR included with NEMA-4X models.

Setpoint Temperature Range: -40 F to 248 F (-40 C to 120 C) Relay Contact Ratings
Sensor Element: 1097 ohms PTC at 77 F (25 C) (24 Vac): 10.0A resistive
Bulb Size: 1/4 in. diameter x 2 in. long (6.35 mm diameter x 50.8 mm) (120 Vac): 1/2 hp; 9.8 AFL, 58.8 ALR, 125 VA Pilot Duty
Accuracy: ±1 F at 77 F (±1 C at 25 C) (240 Vac): 1/2 hp; 4.9 AFL, 29.4 ALR, 125 VA Pilot Duty
Maximum distance to sensor: Up to 1,000 ft (up to 304 m) Approvals:
Voltage: 24 Vac or 120/240 Vac C-Tick: Approved
Frequency: 60 Hz; 50 Hz Underwriters Laboratories, Inc. Approved
Operating Ambient Temperature Range: CE: Approved
-40 F to 140 F @ 60 Hz (-40 C to 60 C @ 60 Hz); Canadian Underwriters Laboratories, Inc. Approved
-40 F to 125 F @ 50 Hz (-40 C to 52 C @ 50 Hz) Other: IP65: Approved
Throttling Range: 1 F to 150 F (0.5 C to 66 C)
Differential Temperature: 1 F to 150 F (0.5 C to 66 C) Accessories:
Analog Output Type (models with Analog Output): 107324A Capillary Holder Assembly for duct insertion, 8 3/8 in. long
2-10 Vdc or 0-10 Vdc or 4-20 mA or Electronic Series 90 C7031D2003 5 inch immersion sensor with well
C7031J2009 1097 ohm Electronic Temperature Sensor
C7100D1001 12 inch Duct Averaging Temperature Sensor
C7130B1009 Wall mount Room Sensor

Analog Relay Sensor Floating Output Sensors Included


Product Number Output Output Inputs Output Reset (Qty) Description Replaces
T775A2009 — 1 SPDT 1 — — 50021579-001 (1) Standard T775A1001
T775B2016 — 2 SPDT 2 1 — T775-SENS-WR (1) Standard- NEMA 4X —
T775B2024 — 4 SPDT 2 2 — T775-SENS-WR (1) Standard- NEMA 4X T775D1008; T775C1009
T775B2032 — 2 SPDT 2 1 — 50021579-001 (1) Standard T775B1000; T775A1019
T775B2040 — 4 SPDT 2 2 — 50021579-001 (1) Standard T775B1042; T775B1026;
T775B1018; T775A1035; T775A1027
T775M2006 2 None 2 — — 50021579-001 (1) Modulating —
T775M2014 2 4 SPDT 2 — — T775-SENS-WR (1) Modulating-NEMA 4X T775G1039; T775G1021;
T775G1013; T775G1005
T775M2022 2 2 SPDT 2 — — T775-SENS-WR (1) Modulating-NEMA 4X —
T775M2030 2 4 SPDT 2 — — 50021579-001 (1) Modulating T775F1089; T775F1055; T775F1022;
T775E1114
T775M2048 2 2 SPDT 2 — — 50021579-001 (1) Modulating T775E1098; T775E1064;
T775E1056; T775E1023; T775E1015
T775R2001 — 4 SPDT 2 2 Yes 50021579-001 (2) Reset Option —
T775R2019 2 4 SPDT 2 — Yes 50021579-001 (2) Reset Option —
T775R2027 2 2 SPDT 2 — Yes 50021579-001 (2) Reset Option T775J1068; T775J1050; T775J1043
T775R2035 — 2 SPDT 2 1 Yes 50021579-001 (2) Reset Option T775J1076; T775J1001
T775R2043 2 — 2 — Yes 50021579-001 (2) Reset Option T775J1035; T775J1027; T775J1019

376 customer.honeywell.com 70-6910


Temperature Controllers
Dimensions in inches (millimeters)

Controls
Home
TOP
BOTTOM
1 (25.5)

7/8 (22.5)

Indoor Air Quality


2 15/16 (74)
7/8 (22.5)

1 (25.5)

4 13/32 (112.1) 1/2 (12.4)


3 31/32 (101)
LEFT RIGHT

Combustion Controls
Residential
4 1/16 (103.4)

1/64 (3.8)

8 5/32
(207.1)

Hydronic Controls
7 23/32
4 1/16 (103.4) (196)
2 13/16 (71.8)
2 11/16 (68.1)

FRONT VIEW 7/8 (22.5)


7/8 (22.5)

M24279

Controls
Water
T775 Series 2000 Cross Reference
Item Replacement Comments
Item Replacement Comments
T775G1013 T775M2014
T775A1001 T775A2009

Building Automation
T775G1021 T775M2014
T775A1019 T775B2032
T775J1001 T775R2035
T775A1027 T775B2040
T775J1019 T775R2043
T775A1035 T775B2040
T775J1027 T775R2043
T775B1000 T775B2032
T775J1035 T775R2043
T775B1018 T775B2040
T775J1043 T775R2027
T775B1026 T775B2040
T775J1050 T775R2027
T775C1009 T775B2024
T775J1068 T775R2027
T775D1008 T775B2024
T775J1076 T775R2035

Components
Commercial
T775E1015 T775M2048
H775A1006 T775U2006
T775E1023 T775M2048
H775A1022 T775U2006
T775E1056 T775M2048
H775A1048 T775U2006 T775U has only two relays, use
T775E1064 T775M2048
two of them.
T775E1098 T775M2048
H775A1063 T775U2006 T775U has only two relays, use
T775E1114 T775M2030 two of them.
T775F1022 T775M2030 H775B1005 T775U2006
Pneumatic Controls

T775F1055 T775M2030 H775C1004 T775U2006 No duct limit reset, T775U has


T775F1089 T775M2030 only two relays, use two of
them.
T775G1005 T775M2014
H775D1003 T775U2006 No duct limit reset
Industrial Combustion
Controls

70-6910 377
Temperature Controllers
T775 Series 2000 Special Stand-Alone Controllers
The T775 electronic remote temperature controllers are the next
generation of commercial and agricultural controls capable of
remote sensing of temperature, humidity, pressure, etc., and
providing switched and/or proportional outputs to various types of
loads.
• Universal model (T775U) can control pressure, humidity, or any
variable analog input.
• Special boiler model (T775P) for boiler control.
• Special Staged Sequencing Model (T775L) for sequence staging of
relays with one or two setpoints.
• Special Expansion Model (T775S) for staging up to 12 relays with
two setpoints (each T775S provides 4 relays).
• Save time on installations with the easy-to-use graphical Interface,
large display, and the intuitive programming.
• Use the time clock scheduler or digital input to control the setback
and disable output options to help save energy.
• Provide very fast or very fast response times on modulating outputs
by adjusting the integral and derivative times (PI or PID).
• Configure models with reset in a few easy steps.
• Eliminate the need for a separate time delay device and protect
equipment with the minimum off time option.
• Use the T775L and T775P to stage up to 12 relays (with optional
T775S) from two independent heat or cool setpoints.
• Support for digital output alarm on the T775P configurable based on
minimum, maximum, or differential temperature.
Dimensions Diagram: See page 377 Accessories:
Setpoint Temperature Range: -40 F to 248 F (-40 C to 120 C) 107324A Capillary Holder Assembly for duct insertion, 8 3/8 in. long
Sensor Element: 1097 ohms PTC at 77 F (25 C) H7655A1001 Humidity Transmitter, 5% RH accuracy, wall mount,
Bulb Size (for T775L and T775P models): without temp output
1/4 in. diameter x 2 in. long (6.35 mm diameter x 50.8 mm) H7655B1009 Humidity Transmitter, 5% RH accuracy, duct mount, with
Accuracy: ±1 F at 77 F (±1 C at 25 C) optional 20K ohm temp output
Maximum distance to sensor: Up to 1,000 ft (up to 304 m) P7640A1000 Differential Pressure Transmitter, 0-1.0, 0-0.5, 0-0.25, or
Voltage: 24 Vac or 120/240 Vac 0-0.1 in. w.c., uni- or bi-directional, panel mount, with display
Frequency: 60 Hz; 50 Hz P7640A1018 Differential Pressure Transmitter, 0-1.0, 0-0.5, 0-0.25, or
Operating Ambient Temperature Range: -40 F to 140 F @ 60 Hz (-40 0-0.1 in. w.c., uni- or bi-directional, panel mount, without display
C to 60 C @ 60 Hz); -40 F to 125 F @ 50 Hz (-40 C to 52 C @ 50 Hz) P7640A1026 Differential Pressure Transmitter, 0-10, 0-5, 0-2.5, 0-1.0
Throttling Range: 1 F to 150 F (0.5 C to 66 C) in. w.c., uni- or bi-directional, panel mount, with display
Analog Output Type: 2-10 Vdc; 0-10 Vdc; 4-20 mA; Electronic Series 90 P7640A1034 Differential Pressure Transmitter, 0-10, 0-5, 0-2.5, 0-1.0
Differential Temperature: 1 F to 150 F (0.5 C to 66 C) in. w.c., uni- or bi-directional, panel mount, without display
Analog Output Type (models with Analog Output): P7640B1008 Differential Pressure Transmitter, 0-1.0, 0-0.5, 0-0.25, or
2-10 Vdc or 0-10 Vdc or 4-20 mA or Electronic Series 90 0-0.1 in. w.c., uni- or bi-directional, duct mount, with display
Relay Contact Ratings P7640B1016 Differential Pressure Transmitter, 0-1.0, 0-0.5, 0-0.25, or
(24 Vac): 10.0A resistive 0-0.1 in. w.c., uni- or bi-directional, duct mount, without display
(120 Vac): 1/2 hp; 9.8 AFL, 58.8 ALR, 125 VA Pilot Duty P7640B1024 Differential Pressure Transmitter, 0-10, 0-5, 0-2.5, 0-1.0
(240 Vac): 1/2 hp; 4.9 AFL, 29.4 ALR, 125 VA Pilot Duty in. w.c., uni- or bi-directional, duct mount, with display
Approvals: P7640B1032 Differential Pressure Transmitter, 0-10, 0-5, 0-2.5, 0-1.0
C-Tick: Approved in. w.c., uni- or bi-directional, duct mount, without display
Underwriters Laboratories, Inc. Approved
CE: Approved
Canadian Underwriters Laboratories, Inc. Approved
Other: IP65: Approved

Stages
Analog Relay Loop Sensor Digital Output Sensors
Product Number Output Output Control Inputs Output Reset Included (Qty) Expandable Description Replaces
T775L2007 — 4 SPDT Yes 2 Yes 50021579-001 Add 1 or 2 T775Ss Stage sequencer with —
(1) (4 relays ea) reset option
T775P2003 — 4 SPDT Yes 3 1 Yes 50021579-001 Add 1 or 2 T775Ss Special boiler with reset —
(3) (4 relays ea) option
T775S2008 — 4 SPDT — — — None — Relay Expansion —
Module
T775U2006 2 2 SPDT — 2 Yes None — Universal - humidity, H775E1002;
(Sensor pressure, etc. H775D1003;
B used H775C1004;
for H775B1005;
reset H775A1063;
only) H775A1048;
H775A1022;
H775A1006
T775U2016 2 2 SPDT — 2 Yes None — Universal-Control to —
sensor A (universal
input) and Sensor B
(temp) independently

378 customer.honeywell.com 70-6910


Temperature Controllers
T915 Proportional Temperature Controller

Controls
Home
Proportional remote bulb controllers for ducts, tanks, boilers,
pipes and other heat exchangers.
• Provide proportioning control of three-wire, low-voltage valve or
damper motors.
• Used to regulate temperatures of either air or liquids.
• All models ambient compensated. Ambient temperature
compensation provides good temperature control. Refer to T775

Indoor Air Quality


Electronic Remote Temperature Controller where more exact control
is required and/or remote controller location is preferred.
• Temperature setting scale markings in both Fahrenheit and Celsius.
Steel case has a clear plastic cover to make setting readily visible.
• Surface mount using two screws through back of case.

Combustion Controls
Residential
Type: Remote bulb Bulb Size: 1/2 in. diameter x 4 in. long (13 mm diameter x 102 mm
Application: Used with Series 90 Modutrol Motors for proportional long)
control of valves and dampers Number of Sensor Inputs: 1
Dimensions, Approximate: 5 1/2 in. high x 4 1/2 in. wide x 2 3/4 in. Color: Gray
deep (140 mm high x 114 mm wide x 70 mm deep) Setpoint Temperature Range: 15 F to 90 F (-10 C to +32 C)

Setpoint Maximum
Temperature Operating Throttling Capillary

Hydronic Controls
Range Temperature Range Length
Output
Product Number (F) (C) (F) (C) (F) (C) (ft) (m) Analog Output Type Sensor Element
T915C1407 15 F to -10 C to 200 F 93 C 7 F to 3.9 C to 20 ft. 6.1 m One 135 Ohm analog Copper bulb, fade-out fill
90 F +32 C 38 F 21.1 C Potentiometer
T915C1928 80 F to 27 C to 230 F 110 C 6 F to 3.3 C to 5 ft 1.5 m One 135 Ohm analog Copper bulb, high
210 F 99 C 32 F 17.8 C Potentiometer temperature fill
T915C1936 80 F to 27 C to 230 F 110 C 6 F to 3.3 C to 20 ft. 6.1 m One 135 Ohm analog Copper bulb, high
210 F 99 C 32 F 17.8 C Potentiometer temperature fill

Controls
Water
Building Automation
Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 379
Temperature Controllers
T991A Proportional Temperature Controller
For modulating control of water or air temperature in ducts, tanks
and similar applications.
• Fast response models (for duct mounting) have coiled sensing
element giving at least four times faster response than standard
models.
• Ambient temperature compensated for the case and tubing.
• Sensing element capillary tubing allows remote mounting of sensing
element.
• Setpoint may be read and adjusted through cover.
• Throttling dial inside case adjusts proportional throttling range.

Dimensions in inches (millimeters) Type: Modulating Remote bulb


Application: Provide modulating control of water or air temperature in
2 ducts or tanks
(51)
Color: Gray
KNOCKOUT FOR Voltage: 24 Vac to 30 Vac
15/16 (24) 1/2-INCH CONDUIT (2)
Frequency: 60 Hz; 50 Hz
Number of Sensor Inputs: 1
2-1/4
(57)
2-1/8
(54)
17/32
1/2 (13)
(13)

4-3/16 5-5/8
(106) (143)
4-3/16
(106)

7/32 DIA.
1 (3)
1-3/16
3/8 (51)
(10)

1 BULB LENGTH IS 3-9/16 (91).ON 55 TO 175 F AND 15 TO 75 C RANGE.


M23881

Setpoint Maximum
Temperature Operating Throttling Capillary
Range Temperature Range Bulb Size Length
Output Analog Sensor
Product Number (F) (C) (F) (C) (F) (C) (inch) (mm) (ft) (m) Type Output Output Element Includes
T991A1004 0 F to -18 C to 125 F 52 C 3 F to 1.7 C to 1/2 in. 13 mm 5 ft 1.5 m analog One 135 Ohm — Copper
100 F +38 C 30 F 16.7 C diameter x diameter x Potentiometer bulb
4 3/16 in. long 107 mm long
T991A1012 0 F to -18 C to 125 F 52 C 3 F to 1.7 C to 1/2 in. 13 mm 20 ft. 6.1 m analog One 135 Ohm — Copper
100 F +38 C 30 F 16.7 C diameter x diameter x Potentiometer bulb
4 3/16 in. long 107 mm long
T991A1061 160 F to 71 C to 280 F 138 C 3 F to 1.7 C to 1/2 in. 13 mm 5 ft 1.5 m analog One 135 Ohm — Copper
260 F 127 C 30 F 16.7 C diameter x diameter x Potentiometer bulb
4 3/16 in. long 107 mm long
T991A1079 160 F to 71 C to 280 F 138 C 3 F to 1.7 C to 1/2 in. 13 mm 20 ft. 6.1 m analog One 135 Ohm — Copper
260 F 127 C 30 F 16.7 C diameter x diameter x Potentiometer bulb
4 3/16 in. long 107 mm long
T991A1095 5 F to -15 C to 125 F 52 C 3 F to 1.7 C to 1/2 in. 13 mm 5 ft 1.5 m analog One 135 Ohm — Copper Celsius
95 F +35 C 30 F 16.7 C diameter x diameter x Potentiometer bulb scale
4 3/16 in. long 107 mm long
T991A1186 55 F to 13 C to 200 F 93 C 3 F to 1.7 C to 1/2 in. 13 mm 5 ft 1.5m analog One 135 Ohm — Copper
175 F 79 C 30 F 16.7 C diameter x diameter x Potentiometer bulb
4 3/16 in. long 107 mm long

380 customer.honeywell.com 70-6910


Temperature Controllers

Controls
Setpoint Maximum

Home
Temperature Operating Throttling Capillary
Range Temperature Range Bulb Size Length
Output Analog Sensor
Product Number (F) (C) (F) (C) (F) (C) (inch) (mm) (ft) (m) Type Output Output Element Includes
T991A1194 55 F to 13 C to 200 F 93 C 3.5 F to 1.9 C to 1/2 in. 13 mm 20 ft. 6.1m analog One 135 Ohm — Copper
175 F 79 C 36 F 20 C diameter x diameter x Potentiometer bulb
3 9/16 in. long 90 mm long

Indoor Air Quality


T991A1210 59 F to 15 C to 200 F 93 C 3 F to 1.7 C to 1/2 in. 13 mm 5 ft 1.5m analog One 135 Ohm — Copper
167F 75 C 10 F 16.7 C diameter x diameter x Potentiometer bulb
4 3/16 in. long 107 mm long
T991A1244 55 F to 13 C to 200 F 93 C 3.5 F to 1.9 C to 1/2 in. 13 mm 5 ft 1.5m analog One 135 Ohm — Copper 107324A
175 F 79 C 36 F 20 C diameter x diameter x Potentiometer bulb Duct Bulb
3 9/16 in. long 90 mm long holder
T991A1269 55 F to 13 C to 200 F 93 C 3.5 F to 1.9 C to 1/2 in. 13 mm 20 ft. 6.1m analog One 280 Ohm — Copper
175 F 79 C 36 F 20 C diameter x diameter x Potentiometer bulb
3 9/16 in. long 90 mm long

Combustion Controls
T991A1343 55 F to 13 C to 200 F 93 C 3.5 F to 1.9 C to 1/2 in. 13 mm 5 ft 1.5m analog One 280 Ohm — Copper 107324A

Residential
175 F 79 C 36 F 20 C diameter x diameter x Potentiometer bulb Duct Bulb
3 9/16 in. long 90 mm long holder
T991A1350 55 F to 13 C to 200 F 93 C 3.5 F to 1.9 C to 7/64 in. 2.8 mm 24 ft. 7.3 m analog One 135 Ohm 1 SPST Copper
175 F 79 C 36 F 20 C diameter x diameter x and relay Potentiometer averaging
24 ft. long 7.3 m long element
T991A1426 0 F to -18 C to 125 F 52 C 3 F to 1.7 C to 1/2 in. 13 mm 5 ft 1.5 m analog One 135 Ohm 1 SPST Copper 107324A
100 F +38 C 10 F 16.7 C diameter x diameter x and relay Potentiometer bulb Duct Bulb
4 3/16 in. long 107 mm long holder

Hydronic Controls
T991A1715 0 F to -18 C to 125 F 52 C 3 F to 1.7 C to 1/8 in. 3 mm 5 ft 1.5 m analog One 135 Ohm 1 SPST Copper fast 131524A
100 F +38 C 10 F 16.7 C diameter x diameter x and relay Potentiometer response duct coil
76 3/8 in. long 1.9 m long element holder
T991A1756 55 F to 13 C to 200 F 93 C 3.5 F to 1.9 C to 1/8 in. 3 mm 5 ft 1.5 m analog One 135 Ohm — Copper fast 131524A
175 F 79 C 36 F 20 C diameter x diameter x Potentiometer response duct coil
76 3/8 in. long 1.9 m long element holder
T991A1764 0 F to -18 C to 125 F 52 C 3 F to 1.7 C to 7/64 in. 2.8 mm 24 ft. 7.3 m analog One 135 Ohm — Copper
100 F +38 C 30 F 16.7 C diameter x diameter x Potentiometer averaging
24 ft. long 7.3 m long element
T991A2069 0 F to -18 C to 125 F 52 C 3 F to 1.7 C to 1/8 in. 3 mm 20 ft. 6.1 m analog One 135 Ohm — Copper fast 131524A

Controls
100 F +38 C 30 F 16.7 C diameter x diameter x Potentiometer response duct coil

Water
76 3/8 in. long 1.9 m long element holder

Building Automation
Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 381
Temperature Controllers
Remote Bulb Controller Accessories
Product
Number Description
107323A Remote Bulb Shield Assembly, 3/8 in. diameter bulbs, < 5 in. long

M17284A

107324A Capillary Holder Assembly for duct insertion, 8 3/8 in. long

M17275A

107408 Heat Conductive Compound, 4 ounces


112620AA Well Assembly., 3 3/4 in. (95 mm) insertion, 3/8 in. (10 mm) diameter, copper
112620BB Well Assembly., 5 1/2 in. (140 mm) insertion, 3/8 in. (10 mm) diameter, copper
112622AA Well Assembly., 4 in. (102 mm) insertion, 1/2 in. (13 mm) diameter, copper
112624AA Well Assembly., 4 3/4 in. (121 mm) insertion, 1/2 in. (13 mm) diameter, stainless steel
112628AA Well Assembly., 4 3/4 in. (121 mm) insertion, 1/2 in. (13 mm) diameter, stainless steel
M17401A
112630AA Well Assembly., 4 1/4 in. (108 mm) insertion, 1/2 in. (13 mm) diameter, copper
112632AA Well Assembly., 4 1/4 in. (108 mm) insertion, 1/2 in. (13 mm) diameter, stainless steel
112634AA Well Assembly., 4 1/4 in. (108 mm) insertion, 1/2 in. (13 mm) diameter, copper
131524A Capillary Holder Assembly., 8 3/8 in. long, duct insertion

M17276A

193987GA Encapsulated platinum sensing element used with the T7075 and T775. 2 5/8 in long,
3/8 in diameter, 6 in. leads.
198212CA Encapsulated platinum sensing element used with the T7075 and T775. Water resistant,
60 in. leads.
203401B Encapsulated platinum PT3000 sensing element used with the T7075 and T775. Water tight,
20 in. leads, requires 1/2 in. diameter well.
311266D Bulb Holder Assembly., T4031, use with copper elements only

M17277A

7617ABZ Bag Assembly., Bracket


7617M Compression Fitting, brass 1/2 in. NPT plug
7617P Compression Fitting, brass 3/4 in. NPT plug
7640HX Mounting Kit, controller and averaging element
Q615A1004 Splash proof enclosure

382 customer.honeywell.com 70-6910


Temperature Controllers
Remote Bulb Controller Parts

Controls
Home
Product Number Description
112719 Packing Ring, Remote Bulb Well
203531A Panel Mount Kit for T775A,B,E,F, or J Electronic Temperature Controller with tamper resistant window
34886A Sun shield for remote bulb controllers,T475, T991B, T678B, T675A

Indoor Air Quality


7617ABY Compression Fitting, brass 1/2 in. NPT plug
801737A 140 ohms Potentiometer and Bracket Assembly for use with T991A
801737A 140 ohms Potentiometer and Bracket Assembly for use with T991A
801737A 140 ohms Potentiometer and Bracket Assembly for use with T991A
801737A 140 ohms Potentiometer and Bracket Assembly for use with T991A

Combustion Controls
Remote Temperature Controller Accessories

Residential
Product Number Description
32004800-001 10K sensor for use with T7079
801534/0638 Calibration wrench for T991, T631, T675, T678, T6031, T475, T4031, T4054, T6054, T6064

Hydronic Controls
Controls
Water
Building Automation
Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 383
Commercial Rectangular Dampers
D1 Series Ultra-low Leakage Design Airfoil Control Damper
The D1 series is an extremely low leakage damper with rugged
steel airfoil blades designed to meet the highest standards
established. It is intended for application in medium to high
pressure and velocity ratings.

Size Range1: Minimum Size: One Blade: 6 in. wide by 6 in. high Leakage Rate
Two Blade: 6 in. wide by 10 in. high
Maximum Size: Single Section: 60 in. wide by 74 in. high 8.5
8.0

STATIC PRESSURE DIFFERENCE (IN. WG)


Multiple Section: unlimited 7.0

Temperature Rating: 180 F (82 C) maximum2


6.0
5.0

Standard Construction3: Blade: 14 gauge galvanized steel, airfoil 4.0

shaped 3.0

Action: Parallel or Opposed


Frame3: 16 gauge galvanized steel Hat-channel
2.0

D1
Bearings3: Synthetic (Acetal)
Linkage3: Steel Side linkage out of airstream (concealed in frame) 1.0
0.9

Axles3: 1/2 in. diameter plated steel


0.8
0.7
0.6
Jamb Seals3: 304 Stainless Steel 0.5

Blade Edge Seals3: Silicone 0.4

0.3
1
Width and height dimensions furnished 1/4 in. undersized - standard 0.2
2
Temperature rating with standard options
3
See Options table for customized options
Dimensions Diagram 1 2 3 4 5 6 7 8 9 10 20 30 40
50
60 80 100
70 90
150

AIR LEAKAGE (CFM/FT2)


M13906

Performance Data
D1 Pressure and Velocity Limits.
Damper Size Maximum System Maximum System
in inches. Pressure Velocity
12 x 12 8.0 in. wg 4000 fpm
24 x 24 8.0 in. wg 4000 fpm
36 x 36 6.3 in. wg 3500 fpm
H
48 x 48 4.7 in. wg 3000 fpm
60 x 60 2.0 in. wg 2500 fpm
Flange Options

SINGLE
STANDARD SINGLE DOUBLE
REVERSE
(NO FLANGE) FLANGE FLANGE
FLANGE
INTERNAL MOUNTING

INTERNAL MOUNTING
ACTUATOR SIDE FOR

ACTUATOR SIDE FOR

M13905

M18986

384 customer.honeywell.com 70-6910


Commercial Rectangular Dampers
D2 and D3 Series Rectangular Volume Control Dampers

Controls
Home
D2 series is an ultra-low leakage control damper which includes
blade and jamb seals. The D3 series is a general purpose damper
intended for applications where low leakage performance is not
necessary.
Honeywell International, Inc. certifies that the
models D2, and D3 shown herein are licensed to

Indoor Air Quality


bear the AMCA Seal. The ratings shown are based
on tests and procedures performed in accordance
with AMCA Publication 511 and comply with the
requirements of the AMCA Certified Ratings
Programs. The AMCA Certified Ratings Seal
applies to air performance ratings only. March
2008.

Combustion Controls
Residential
Size Range1: Minimum Size: One Blade: 6 in. wide by 6 in. high Leakage Rate
Two Blade: 6 in. wide by 10 in. high
Maximum Size: Single Section: 48 in. wide by 72 in. high 6.0
Multiple Section: unlimited 5.0

STATIC PRESSURE DIFFERENCE (IN. WG)


4.0
Temperature Rating: 180 F (82 C) maximum
Standard Construction2: Blade: 16 gauge galvanized steel 3-V
3.0

Action: Parallel or Opposed 2.0

Hydronic Controls
Frame2: 16 gauge galvanized steel Hat-channel

D3
D2
Bearings2: Synthetic (Acetal) 1.0
Linkage: Side linkage out of airstream (concealed in frame) .8
Axles: 1/2 in. square plated steel .6
Jamb Seals3: Compression-type Stainless Steel .5
.4
Blade Edge Seals2: Extruded Vinyl .3

1
Width and height dimensions furnished 1/4 in. undersized - standard .2
2
See Options table for customized options
3
D2 Dampers only

Controls
Water
1 2 3 4 5 6 8 10 20 30 50 80 150
Dimensions Diagram 40 60 100
AIR LEAKAGE (CFM/FT2)
M23317A

Performance Data
D2, D3 Pressure and Velocity Limits.

Building Automation
Damper Size Maximum System Maximum System
in inches. Pressure Velocity
12 x 12 5.0 in. wg 3000 fpm
24 x 24 5.0 in. wg 3000 fpm
H
36 x 36 4.0 in. wg 2500 fpm
48 x 48 2.5 in. wg 2000 fpm
NOTE: D2 and D3 will withstand higher pressures and velocities. Dis-
played ratings are conservative to prevent misapplication.
Consult Honeywell if you have an application outside these

Components
Commercial
limitations.
Flange Options

SINGLE
STANDARD SINGLE DOUBLE
REVERSE
(NO FLANGE) FLANGE FLANGE
W FLANGE

M20587
Pneumatic Controls
INTERNAL MOUNTING

INTERNAL MOUNTING
ACTUATOR SIDE FOR

ACTUATOR SIDE FOR

Industrial Combustion
Controls

M18986

70-6910 385
Commercial Rectangular Dampers
Standard Models

D2 D642 (Class II Leakage, 3 V blade with seals)


Product Type
D3 D640 (Class III Leakage, 3 V blade without seals)
P Parallel
Blade Action
O Opposed
A 16 gauge galvanized frame with galvanized linkages and axles Frame
A Acetal Bearings /No Seal
B Acetal Bearings/Vinyl Seal Axle Bearings and Seals Materials (When you
select D3 you are only selecting the bearing
C Bronze Bearings/No Seal type)
D Bronze Bearings/Vinyl Seal
(006- Standard Rectangular Damper Width Width (in 2 inch increments through 46 in.
072) then 4 in. increments through 72 in.)
(006- Standard Rectangular Damper Height Height (in 2 inch increments through 46 in.
072) then 4 in. increments through 72 in.)
N Nominal Sizing Sizing
A No flange Flange
External LH Standard without
jackshaft (may include jackshaft
A for larger sizes)
Internal LH Standard without
jackshaft (may include jackshaft Actuator Mounting
B for larger sizes)
External RH Standard without
jackshaft (may include jackshaft
C for larger sizes)

D2 P B* A XXX XXX N A A Example


* Contact Customer Care for additional options and models.

Options
Frame Jamb Linkage
Material Gauge Blade Seals Seals Bearings Axles Materials Flange Sizing
S = Standard
O = Optional Galv S/S 16 14 12 Vinyl Silicone S/S Synthetic Bronze S/S Steel S/S Steel S/S None Single Double Reverse Nominal Actual
D1 Ultra-low S O S O O N/A S S S O O S O S O S O O O S O
Leakage Airfoil
Volume Control
Damper

Frame Jamb Linkage


Material Gauge Blade Seals Seals Bearings Axles Materials Flange Sizing
S = Standard
O = Optional Galv S/S Al 16 14 12 Vinyl Silicone S/S Synthetic Bronze S/S Steel S/S Steel S/S None Single Double Reverse Nominal Actual
D3 Standard S O O S O O N/A N/A N/A S O O S O S O S O O O S O
Volume Control
Damper
D2 Ultra-low S O O S O O S O S S O O S O S O S O O O S O
Leakage
Volume Control
Damper

Rectangular Damper Accessories


Product Number Description
106783A Damper Crank Assembly for 1/2 inch diameter axle
14000028-001 Nylon Bearing
14000644-002 Drive Bracket for D640 and D641 (included in Q605D1069)
14000644-004 Drive Bracket for D640 and D641
14004096-001 Drive Bracket Right
27514B Damper crank arm for 3/4 in. damper shaft

386 customer.honeywell.com 70-6910


Commercial Round Dampers
D690 Low-Leakage, Single-Blade, Round Dampers

Controls
Home
The D690 Round Damper is used in conventional air handling
systems to control airflow in a round duct. The damper is designed
for use with Honeywell ML6161 and ML7161 Direct Coupled
Actuators.
• Neoprene seal for tight closing and low leakage.
• Oilite bearings for long life.
• 90 degree damper travel for a variety of applications.

Indoor Air Quality


Dimensions in millimeters (inches)

Combustion Controls
Application: heating, cooling, ventilating
Type of Blade: Single-blade, round

Residential
Temperature Range: 32 F to 130 F (0 C to 54 C)
Integral Actuator: None
Input Signal: none
Used With: ML6161; ML7161; W7751 VAV Controller
W

Hydronic Controls
L

DAMPER DIAMETER (D) WIDTH (W) LENGTH (L)


in. mm in. mm in. mm
6 152 9-1/2 241 12 305

Controls
Water
8 203 11-1/2 292 12 305
10 254 13-1/2 343 12 305
12 305 15-1/2 394 13 330
14 356 17-1/2 445 15 381
16 406 19-1/2 495 17 432
M17412

Building Automation
Diameter
Maximum Approach
Product Number (inch) (mm) Velocity (ft/ min) Description
* D690A1002 6 in. diameter 152 mm diameter 2500 ft/min 6 inch, Single Blade Round Damper, for use with ML6161 and
ML7161 actuators or W7751 VAV Controller
* D690A1010 8 in. diameter 203 mm diameter 2500 ft/min 8 inch, Single Blade Round Damper, for use with ML6161 and
ML7161 actuators or W7751 VAV Controller
* D690A1028 10 in. diameter 254 mm diameter 2500 ft/min 10 inch, Single Blade Round Damper, for use with ML6161
and ML7161 actuators or W7751 VAV Controller
* D690A1036 12 in. diameter 305 mm diameter 2500 ft/min 12 inch, Single Blade Round Damper, for use with ML6161

Components
Commercial
and ML7161 actuators or W7751 VAV Controller
* D690A1044 14 in. diameter 356 mm diameter 2500 ft/min 14 inch, Single Blade Round Damper, for use with ML6161
and ML7161 actuators or W7751 VAV Controller
* D690A1051 16 in. diameter 406 mm diameter 2500 ft/min 16 inch, Single Blade Round Damper, for use with ML6161
and ML7161 actuators or W7751 VAV Controller
* TRADELINE models • SUPER TRADELINE models
Pneumatic Controls
Industrial Combustion
Controls

70-6910 387
Commercial Round Dampers
DM7600 Commercial Zone Damper
The DM7600 Commercial Zone Damper is used in zoning systems
to control airflow in a round duct. A Honeywell ML6161 or ML7161
Direct Coupled Actuator is factory mounted to the damper to
simplify field installation.
• Neoprene seal for tight closing and low leakage.
• Oilite bearings for long life.
• 90 degree damper travel for a variety of applications.
• Magnetic coupling requires no limit switches or mechanical stops.

Application: heating, cooling, ventilating


Type of Blade: Single-blade, round
Temperature Range: 32 F to 130 F (0 C to 54 C)
Voltage: 24 Vac
Frequency: 50 Hz; 60 Hz

Diameter Maximum
Approach
Product Number (inch) (mm) Integral Actuator Velocity (ft/ min) Input Signal Timing (sec)
DM7600A1005 6 in. diameter 152 mm diameter 2 to 10 Vdc or 4 to 20 mA, 2500 ft/min 2 to 10 Vdc or 4 90 sec
ML7161A2008 to 20 mA
DM7600A1013 8 in. diameter 203 mm diameter 2 to 10 Vdc or 4 to 20 mA, 2500 ft/min 2 to 10 Vdc or 4 90 sec
ML7161A2008 to 20 mA
DM7600A1021 10 in. diameter 254 mm diameter 2 to 10 Vdc or 4 to 20 mA, 2500 ft/min 2 to 10 Vdc or 4 90 sec
ML7161A2008 to 20 mA
DM7600A1039 12 in. diameter 305 mm diameter 2 to 10 Vdc or 4 to 20 mA, 2500 ft/min 2 to 10 Vdc or 4 90 sec
ML7161A2008 to 20 mA
DM7600A1047 14 in. diameter 356 mm diameter 2 to 10 Vdc or 4 to 20 mA, 2500 ft/min 2 to 10 Vdc or 4 90 sec
ML7161A2008 to 20 mA
DM7600A1054 16 in. diameter 406 mm diameter 2 to 10 Vdc or 4 to 20 mA, 2500 ft/min 2 to 10 Vdc or 4 90 sec
ML7161A2008 to 20 mA
DM7600B1004 6 in. diameter 152 mm diameter SPDT ; Floating, ML6161A2009 2500 ft/min SPDT Floating 90 sec
DM7600B1012 8 in. diameter 203 mm diameter SPDT ; Floating, ML6161A2009 2500 ft/min SPDT Floating 90 sec
DM7600B1020 10 in. diameter 254 mm diameter SPDT; Floating, ML6161A2009 2500 ft/min SPDT Floating 90 sec
DM7600B1038 12 in. diameter 305 mm diameter SPDT ; Floating, ML6161A2009 2500 ft/min SPDT Floating 90 sec
DM7600B1046 14 in. diameter 356 mm diameter SPDT; Floating, ML6161A2009 2500 ft/min SPDT Floating 90 sec
DM7600B1053 16 in. diameter 406 mm diameter SPDT ; Floating, ML6161A2009 2500 ft/min SPDT Floating 90 sec
* TRADELINE models • SUPER TRADELINE models

388 customer.honeywell.com 70-6910


Direct Coupled Damper Actuators—Spring Return
S03 Series: MS4103; MS7403; MS7503; MS8103

Controls
Home
Spring Return Direct Coupled Actuator, 27 lb-in
MS4103, MS7403, MS7503, and MS8103 Spring Return Direct
Coupled Actuators (DCA) are used within heating, ventilating, and
air-conditioning (HVAC) systems. They can drive a variety of
quarter-turn, final control elements requiring spring return fail-safe
operation.

Indoor Air Quality


• Brushless DC submotor with electronic stall protection on all models
• Self-centering shaft adaptor (shaft coupling) for wide range of shaft
sizes
• Models available for use with two-position, SPST, line- (Series 40) or
low- (Series 80) voltage controls
• Models available for use with floating or switched SPDT (Series 60)
controls
• Models avail able for use with proportional current or voltage (Series
70) controls

Combustion Controls
• Models available with combined floating and modulating control in a
single device

Residential
• Models available with an internal end switch
• Access cover to facilitate connectivity
• Durable plastic housing with built-in mechanical end limits
• Spring return direction field selectable
• Shaft position indicator and scale
• UL (cUL) listed and CE compliant
• All models are plenum rated per UL873

Hydronic Controls
Dimensions in inches (millimeters) Actuator Type: Damper; Valve
Rotational Stroke: 95 ±3 degrees
3-55/64 (98)
3-5/32 (80)
Fail Safe Mode: Spring Return
1-9/16
(40)
1-15/16
(49) 2-27/64 (61)
47/64 Torque: 27 lb-in. (3 Nm)
(19)
Spring Return Torque: 27 lb-in (3 Nm)
1-1/8 Spring Return Direction: By orientation
(29) External Auxiliary Switches Available: No
Electrical Connections: Enclosed screw terminal strip (22 to 14 AWG)
1-1/16 Ingress Protection Rating: IP54
(27) Environmental Rating: NEMA2
Frequency: 50 Hz; 60 Hz

Controls
Water
Mounting: Direct Coupled
4-9/16 Maximum Noise Rating, Holding (dBA @ 1m): 20 (no audible noise)
(116) 6-61/64 Maximum Noise Rating, Driving (dBA @ 1m): 50
(177)
Rotation to Open: By switch
5-27/32 Rotational Stroke Adjustment: Mechanically limited 5 degree
(148)
increments
Compatible Damper Shafts: 3/8 to 5/8 in. round or 1/4 to 1/2 in. square

Building Automation
(9 to 16 mm round or 6 to 13 mm square)
Shaft Adapter Type: Self-centering clamping
Materials: Plenum rated plastic housing
Operating Humidity Range (% RH): 5 to 95% RH, non-condensing
Ambient Temperature Range: .-40 F to +149F F (-40 C to +65 C)
-22 F to +149F (-30 C to +65 C) for two-position actuators only
2-1/64
(55) M27712A Temperature Ratings (Shipping): .-40 F to +150F (-40 C to +65 C)
Storage Temperature Range: .-40 F to +150F (-40 C to +65 C)
Weight: 3.5 lb (1.6 kg)
Includes: Mounting bracket, self-centering shaft adapter

Components
Commercial
Approvals:
CE: EMC 2004/108/EC; Certification Low Voltage Directive 2006/95/
EC; IEC 60730-1 and Part 2-14
C-Tick: N314
Underwriters Laboratories, Inc. UL 873
Canadian Underwriters Laboratories, Inc. cUL C22.2 No. 24-93 Pneumatic Controls
Industrial Combustion
Controls

70-6910 389
Direct Coupled Damper Actuators—Spring Return
Timing (seconds)
Number of Type of
Nominal Maximum Power Internal Internal
Driving Spring Consumption Supply Input Auxiliary Auxiliary Switch
Product Number Control Signal Feedback @ 60 Hz Return (Driving) Voltage Impedance Switch Switch Ratings
MS4103A1030 Two position; SPST — 45 sec 25 sec 10 VA 100 to — 0 — —
250 Vac
MS4103A1130 Two position; SPST — 45 sec 25 sec 10 VA 100 to — 1 adjustable 250 Vac, 8 A
250 Vac 0-95 degrees res (5 A ind)
MS7403A2030 3 kOhm2-10 Vdc 2-10 Vdc 90 sec 25 sec 7 VA 24 Vac/dc Min. 95 0 Min. Pos. —
(4-20 mA w/500 kOhm
ohm resistor);
Floating; Three
position
MS7503A2030 (0)2-10 Vdc (4-20 (0)2-10 Vdc 90 sec 25 sec 7 VA 24 Vac/dc Min. 95 0 — —
mA w/500 ohm kOhm
resistor); Floating
MS7503A2130 (0)2-10 Vdc (4-20 (0)2-10 Vdc 90 sec 25 sec 7 VA 24 Vac/dc Min. 95 1 adjustable 250 Vac, 8 A
mA w/500 ohm kOhm 0-95 degrees res (5 A ind)
resistor); Floating
MS8103A1030 Two position; SPST — 45 sec 25 sec 7 VA 24 Vac/dc — —
MS8103A1130 Two position; SPST — 45 sec 25 sec 7 VA 24 Vac/dc adjustable 250 Vac, 8 A
0-95 degrees res (5 A ind)
Wiring for low-voltage two-position control Wiring for floating control

ACTUATOR
1 1
1 24 VAC SPST 1 24 VAC
2 V 2 V
2 2

3 0°-90°

4 90°-0°
ACTUATOR
5 FEEDBACK
1 LINE VOLTAGE POWER SUPPLY.
1 LINE VOLTAGE POWER SUPPLY. PROVIDE DISCONNECT MEANS 2-10 VDC
PROVIDE DISCONNECT MEANS AND
AND OVERLOAD PROTECTION AS REQUIRED. 10-2 VDC
OVERLOAD PROTECTION AS REQUIRED.
3 0-10 VDC
2 24 VDC SUPPLY ACCEPTABLE. M29512 10-0 VDC
2 24 VDC SUPPLY ACCEPTABLE.
Fltg, fwd
Wiring for line-voltage two-position control 3 SET SWITCH TO FLOATING. Fltg, rev
M29515

Wiring for (0)2-10 Vdc proportioning controllers


1
1 SPST V
2 ACTUATOR
1
1 24 VAC V
2
2

0/2 TO 10 VDC 3 0°-90°


ACTUATOR
PROPORTIONING
4 90°-0°
CONTROLLER
1 LINE VOLTAGE POWER SUPPLY. PROVIDE DISCONNECT MEANS
5 FEEDBACK
AND OVERLOAD PROTECTION AS REQUIRED. M29513 –
2-10 VDC
Wiring for SPDT on/off control + 10-2 VDC
3 0-10 VDC
FEEDBACK 10-0 VDC
ACTUATOR Fltg, fwd
Fltg, rev
1
1 24 VAC
2 V 1 LINE VOLTAGE POWER SUPPLY. PROVIDE DISCONNECT MEANS
2 AND OVERLOAD PROTECTION AS REQUIRED.

3 0°-90° 2 24 VDC SUPPLY ACCEPTABLE.

4 90°-0° 3 SET SWITCH TO MODULATING. M29516


SPDT
5 FEEDBACK

2-10 VDC
10-2 VDC
1 LINE VOLTAGE POWER SUPPLY. 3 0-10 VDC
PROVIDE DISCONNECT MEANS AND 10-0 VDC
OVERLOAD PROTECTION AS REQUIRED. Fltg, fwd
Fltg, rev
2 24 VDC SUPPLY ACCEPTABLE.

3 SET SWITCH TO FLOATING. M29514

390 customer.honeywell.com 70-6910


Direct Coupled Damper Actuators—Spring Return
Wiring for 4-10 mA proportioning controllers Wiring for (0)2-10 Vdc proportioning controllers operating multiple

Controls
Home
actuators
ACTUATOR
ACTUATOR
1
1 24 VAC V 1
2 1 24 VAC
2 2 V
2
3 0°-90°
4 TO 20 mA 490 TO 510 3 0°-90°

Indoor Air Quality


PROPORTIONING OHMS, 4 90°-0° 0/2 TO 10 VDC
CONTROLLER 1/2 W PROPORTIONING 4 90°-0°
MINIMUM 5 FEEDBACK CONTROLLER
– 5 FEEDBACK
2-10 VDC –
+ 10-2 VDC 2-10 VDC
0-10 VDC + 10-2 VDC
3
FEEDBACK 10-0 VDC 3 0-10 VDC
Fltg, fwd FEEDBACK 10-0 VDC
Fltg, rev Fltg, fwd
Fltg, rev
1 LINE VOLTAGE POWER SUPPLY.

Combustion Controls
PROVIDE DISCONNECT MEANS AND
OVERLOAD PROTECTION AS REQUIRED.
ACTUATOR

Residential
2 24 VDC SUPPLY ACCEPTABLE. 1
V
3 SET SWITCH TO MODULATING. M29508 2

Wiring for 3 kOhm Economizer controllers 3 0°-90°

4 90°-0°
ACTUATOR
5 FEEDBACK
1 1 LINE VOLTAGE POWER SUPPLY.

Hydronic Controls
24 VAC V 2-10 VDC
PROVIDE DISCONNECT MEANS AND
2 OVERLOAD PROTECTION AS REQUIRED. 10-2 VDC
3 0-10 VDC
3 0°-90° OR + 2 24 VDC SUPPLY ACCEPTABLE. 10-0 VDC
Fltg, fwd
4 90°-0° OR N/A 3 SET SWITCH TO MODULATING.
SENSOR Fltg, rev
5 FEEDBACK M29509

3KΩ
+ Override to full open

1 EXTERNAL MINIMUM POSITION POT CAN BE APPLIED TO ACTUATOR


TERMINAL 4 90°-0°. M29510
1

Controls
1 24 VAC

Water
V
Wiring for 3 position Economizer controllers 2
2

3 0°-90° OR +
ACTUATOR 0/2 TO 10 VDC
PROPORTIONING 4 90°-0° OR N/A
1 CONTROLLER
24 VAC V 5 FEEDBACK
2 –

Building Automation
3 2-10 VDC
0°-90° OR +
+ 10-2 VDC
SPDT 0-10 VDC
4 90°-0° OR N/A 3
SENSOR FEEDBACK 10-0 VDC
5 FEEDBACK Fltg, fwd
– Fltg, rev

+ 1 LINE VOLTAGE POWER SUPPLY.


PROVIDE DISCONNECT MEANS AND
OVERLOAD PROTECTION AS REQUIRED.
1 EXTERNAL MINIMUM POSITION POT CAN BE APPLIED TO
M29511 2 24 VDC SUPPLY ACCEPTABLE.
TERMINAL 4 90°-0°.
3 SET SWITCH TO MODULATING. M27827

Components
Commercial
Override to full closed

ACTUATOR
1
1 24 VAC V
2
2

3 0°-90° OR +
0/2 TO 10 VDC
Pneumatic Controls

PROPORTIONING 4 90°-0° OR N/A


CONTROLLER
5 FEEDBACK

2-10 VDC
+ 10-2 VDC
SPST 0-10 VDC
3
FEEDBACK 10-0 VDC
Fltg, fwd
Fltg, rev
1 LINE VOLTAGE POWER SUPPLY.
Industrial Combustion

PROVIDE DISCONNECT MEANS AND


OVERLOAD PROTECTION AS REQUIRED.
Controls

2 24 VDC SUPPLY ACCEPTABLE.

3 SET SWITCH TO MODULATING. M27828

70-6910 391
Direct Coupled Damper Actuators—Spring Return
S05 Series: MS4105; MS7405; MS7505; MS8105
Spring Return Direct Coupled Actuator, 44 lb-in
MS4103, MS7403, MS7503, and MS8103 Spring Return Direct
Coupled Actuators (DCA) are used within heating, ventilating, and
air-conditioning (HVAC) systems. They can drive a variety of
quarter-turn, final control elements requiring spring return fail-safe
operation.
• Feature Bullets
• Brushless DC submotor with electronic stall protection on all models
• Self-centering shaft adaptor (shaft coupling) for wide range of shaft
sizes
• Models available for use with two-position, SPST, line- (Series 40) or
low- (Series 80) voltage controls
• Models available for use with floating or switched SPDT (Series 60)
controls
• Models avail able for use with proportional current or voltage (Series
70) controls
• Models available with combined floating and modulating control in a
single device
• Models available with an internal end switch
• Access cover to facilitate connectivity
• Durable plastic housing with built-in mechanical end limits
• Spring return direction field selectable
• Shaft position indicator and scale
• UL (cUL) listed and CE compliant
• All models are plenum rated per UL873

Dimensions in inches (millimeters) Actuator Type: Damper; Valve


Rotational Stroke: 95 ±3 degrees
3-55/64 (98)
3-5/32 (80)
Fail Safe Mode: Spring Return
1-9/16
(40)
1-15/16
(49) 2-27/64 (61)
47/64 Torque: 44 lb-in. (5 Nm)
(19)
Spring Return Torque: 44 lb-in. (5 Nm)
1-1/8 Spring Return Direction: By orientation
(29) External Auxiliary Switches Available: No
Electrical Connections: Enclosed screw terminal strip (22 to 14 AWG)
1-1/16 Environmental Rating: NEMA2
(27) Ingress Protection Rating: IP54
Frequency: 50 Hz; 60 Hz
Mounting: Direct Coupled
4-9/16 Maximum Noise Rating, Holding (dBA @ 1m): 20 (no audible noise)
(116) 6-61/64 Maximum Noise Rating, Driving (dBA @ 1m): 50
(177)
Rotation to Open: By switch
5-27/32 Rotational Stroke Adjustment: Mechanically limited 5 degree
(148)
increments
Compatible Damper Shafts: 3/8 to 5/8 in. round or 1/4 to 1/2 in. square
(9 to 16 mm round or 6 to 13 mm square)
Shaft Adapter Type: Self-centering clamping
Materials: Plenum rated plastic housing
Operating Humidity Range (% RH): 5 to 95% RH, non-condensing
Ambient Temperature Range: .-40 F to +149F F (-40 C to +65 C)
-22 F to +149F (-30 C to +65 C) for two-position actuators only
2-1/64
(55) M27712A Temperature Ratings (Shipping): .-40 F to +150F (.-40 C to +65 C)
Storage Temperature Range: .-40 F to +150F (.-40 C to +65 C)
Weight: 3.5 lb (1.6 kg)
Includes: Mounting bracket, self-centering shaft adapter
Approvals:
CE: EMC 2004/108/EC; Certification Low Voltage Directive 2006/95/
EC; IEC 60730-1 and Part 2-14
C-Tick: N314
Underwriters Laboratories, Inc. UL 873
Canadian Underwriters Laboratories, Inc. cUL C22.2 No. 24-93

392 customer.honeywell.com 70-6910


Direct Coupled Damper Actuators—Spring Return

Controls
Home
Timing (seconds)
Number
Maximum of Type of
Nominal Spring Power Internal Internal
Driving Return Consumption Supply Input Auxiliary Auxiliary Switch
Product Number Control Signal Feedback @ 60 Hz (sec) (Driving) Voltage Impedance Switch Switch Ratings
MS4105A1030 Two position; SPST — 45 sec 25 sec 11 VA 100 to 250 — 0 — —
Vac

Indoor Air Quality


MS4105A1130 Two position; SPST — 45 sec 25 sec 11 VA 100 to 250 — 1 adjustable 250 Vac, 8 A
Vac 0-95 degrees res (5 A ind)
MS7405A2030 3 kOhm2-10 Vdc 2-10 Vdc 90 sec 25 sec 8 VA 24 Vac/dc Min. 95 0 Min. Pos. —
(4-20 mA w/500 ohm kOhm
resistor); Floating;
Three position
MS7505A2030 (0)2-10 Vdc (4-20 (0)2-10 Vdc 90 sec 25 sec 8 VA 24 Vac/dc Min. 95 0 — —
mA w/500 ohm kOhm

Combustion Controls
resistor); Floating

Residential
MS7505A2130 (0)2-10 Vdc (4-20 (0)2-10 Vdc 90 sec 25 sec 8 VA 24 Vac/dc Min. 95 1 adjustable 250 Vac, 8 A
mA w/500 ohm kOhm 0-95 degrees res (5 A ind)
resistor); Floating
MS8105A1030 Two position; SPST — 45 sec 25 sec 8 VA 24 Vac/dc — 0 — —
MS8105A1130 Two position; SPST — 45 sec 25 sec 8 VA 24 Vac/dc — 1 adjustable 250 Vac, 8 A
0-95 degrees res (5 A ind)
* TRADELINE models • SUPER TRADELINE models

Hydronic Controls
Wiring for low-voltage two-position control Wiring for floating control

ACTUATOR
1 1
1 24 VAC SPST 1 24 VAC
2 V 2 V
2 2

3 0°-90°

4 90°-0°
ACTUATOR
5 FEEDBACK

Controls
Water
1 LINE VOLTAGE POWER SUPPLY.
1 LINE VOLTAGE POWER SUPPLY. PROVIDE DISCONNECT MEANS 2-10 VDC
PROVIDE DISCONNECT MEANS AND
AND OVERLOAD PROTECTION AS REQUIRED. 10-2 VDC
OVERLOAD PROTECTION AS REQUIRED.
3 0-10 VDC
2 24 VDC SUPPLY ACCEPTABLE. M29512 10-0 VDC
2 24 VDC SUPPLY ACCEPTABLE.
Fltg, fwd
Wiring for line-voltage two-position control 3 SET SWITCH TO FLOATING. Fltg, rev
M29515

Building Automation
Wiring for (0)2-10 Vdc proportioning controllers
1
1 SPST V
2 ACTUATOR
1
1 24 VAC V
2
2

0/2 TO 10 VDC 3 0°-90°


ACTUATOR
PROPORTIONING
4 90°-0°
CONTROLLER
1 LINE VOLTAGE POWER SUPPLY. PROVIDE DISCONNECT MEANS
5 FEEDBACK

Components
Commercial
AND OVERLOAD PROTECTION AS REQUIRED. M29513 –
2-10 VDC
Wiring for SPDT on/off control + 10-2 VDC
3 0-10 VDC
FEEDBACK 10-0 VDC
ACTUATOR Fltg, fwd
Fltg, rev
1
1 24 VAC
2 V 1 LINE VOLTAGE POWER SUPPLY. PROVIDE DISCONNECT MEANS
2 AND OVERLOAD PROTECTION AS REQUIRED.
Pneumatic Controls

3 0°-90° 2 24 VDC SUPPLY ACCEPTABLE.

4 90°-0° 3 SET SWITCH TO MODULATING. M29516


SPDT
5 FEEDBACK

2-10 VDC
10-2 VDC
1 LINE VOLTAGE POWER SUPPLY. 3 0-10 VDC
PROVIDE DISCONNECT MEANS AND 10-0 VDC
Fltg, fwd
Industrial Combustion

OVERLOAD PROTECTION AS REQUIRED.


Fltg, rev
2 24 VDC SUPPLY ACCEPTABLE.
Controls

3 SET SWITCH TO FLOATING. M29514

70-6910 393
Direct Coupled Damper Actuators—Spring Return
Wiring for 4-10 mA proportioning controllers Override to full open

ACTUATOR ACTUATOR
1 1
1 24 VAC V 1 24 VAC V
2 2
2 2

3 0°-90° 3 0°-90° OR +
4 TO 20 mA 490 TO 510 0/2 TO 10 VDC
PROPORTIONING OHMS, 4 90°-0° PROPORTIONING 4 90°-0° OR N/A
CONTROLLER 1/2 W CONTROLLER
MINIMUM 5 FEEDBACK 5 FEEDBACK
– –
2-10 VDC 2-10 VDC
+ 10-2 VDC + 10-2 VDC
0-10 VDC SPDT 0-10 VDC
3 3
FEEDBACK 10-0 VDC FEEDBACK 10-0 VDC
Fltg, fwd Fltg, fwd
Fltg, rev Fltg, rev
1 LINE VOLTAGE POWER SUPPLY. 1 LINE VOLTAGE POWER SUPPLY.
PROVIDE DISCONNECT MEANS AND PROVIDE DISCONNECT MEANS AND
OVERLOAD PROTECTION AS REQUIRED. OVERLOAD PROTECTION AS REQUIRED.

2 24 VDC SUPPLY ACCEPTABLE. 2 24 VDC SUPPLY ACCEPTABLE.

3 SET SWITCH TO MODULATING. 3 SET SWITCH TO MODULATING. M27827


M29508

Wiring for (0)2-10 Vdc proportioning controllers operating multiple Override to full closed
actuators
ACTUATOR
ACTUATOR 1
1 24 VAC V
1 2
1 24 VAC V 2
2
2
3 0°-90° OR +
0/2 TO 10 VDC
3 0°-90° PROPORTIONING
0/2 TO 10 VDC 4 90°-0° OR N/A
PROPORTIONING CONTROLLER
4 90°-0°
CONTROLLER 5 FEEDBACK
5 FEEDBACK –
– 2-10 VDC
2-10 VDC + 10-2 VDC
+ 10-2 VDC SPST 0-10 VDC
3
0-10 VDC FEEDBACK 10-0 VDC
3
FEEDBACK 10-0 VDC Fltg, fwd
Fltg, fwd Fltg, rev
Fltg, rev 1 LINE VOLTAGE POWER SUPPLY.
PROVIDE DISCONNECT MEANS AND
OVERLOAD PROTECTION AS REQUIRED.
ACTUATOR
2 24 VDC SUPPLY ACCEPTABLE.
1
V
3 SET SWITCH TO MODULATING. M27828
2

3 0°-90°

4 90°-0°

5 FEEDBACK
1 LINE VOLTAGE POWER SUPPLY.
PROVIDE DISCONNECT MEANS AND 2-10 VDC
OVERLOAD PROTECTION AS REQUIRED. 10-2 VDC
3 0-10 VDC
2 24 VDC SUPPLY ACCEPTABLE. 10-0 VDC
Fltg, fwd
3 SET SWITCH TO MODULATING. Fltg, rev
M29509

394 customer.honeywell.com 70-6910


Direct Coupled Damper Actuators—Spring Return
S10 Series: MS4110; MS7510; MS8110

Controls
Home
Spring Return Direct Coupled Actuator, 88 lb-in
MS4110, MS7510, MS8110 S10 Series Spring Return Direct Coupled
Actuators (DCA) are used within heating, ventilating, and air-
conditioning (HVAC) systems. They can drive a variety of quarter-
turn, final control elements requiring spring return fail-safe
operation.

Indoor Air Quality


• Brushless DC submotor with electronic stall protection for floating/
modulating models.
• Brush DC submotor with electronic stall protection for 2-position
models.
• Self-centering shaft adapter (shaft coupling) for wide range of shaft
sizes.
• Models available for use with two-position, single pole single throw
(spst), line- (Series 40) or low- (Series 80) voltage controls.
• Models available for use with floating or switched single-pole,

Combustion Controls
double-throw (spdt) (Series 60) controls.
• Models available for use with proportional current or voltage (Series

Residential
70) controls.
• Models available with combined floating/modulating control in a
single device.
• Models available with adjustable zero and span.
• Models available with line-voltage internal end switches.
• Access cover to facilitate connectivity.
• Metal housing with built-in mechanical end limits.
• Spring return direction field-selectable.

Hydronic Controls
• Shaft position indicator and scale.
• Manual winding capability with locking function.
• UL (cUL) listed and CE compliant.
• All Models are plenum-rated per UL873.

Dimensions in inches (millimeters) Actuator Type: Damper; Valve


Rotational Stroke: 95 ±3 degrees
3-15/16 (100) Fail Safe Mode: Spring Return
1-9/16 1-9/16 Torque: 88 lb-in. (10 Nm)
(40) (40) Spring Return Torque: 88 lb-in. (10 Nm)
Spring Return Direction: By orientation

Controls
External Auxiliary Switches Available: Yes, SW2-US

Water
1-9/16 Electrical Connections: Enclosed screw terminal strip (22 to 14 AWG)
(40) Environmental Rating: NEMA2
Frequency: 50 Hz; 60 Hz
Manual operation: Manual crank
Mounting: Direct Coupled
Maximum Noise Rating, Holding (dBA @ 1m): 20 (no audible noise)

Building Automation
Maximum Noise Rating, Driving (dBA @ 1m): 40
Rotational Stroke Adjustment: Mechanically limited 5 degree
increments
Compatible Damper Shafts:
9-3/4 3/8 to 1.06 in. round or 3/8 to 11/16 in. square
(247) (10 to 27 mm round or 10 to 18 mm square)
Shaft Adapter Type: Self-centering clamping
Materials: Aluminum housing, Plenum rated plastic access cover
6-1/8
(156)
Operating Humidity Range (% RH): 5 to 95% RH, non-condensing
Ambient Temperature Range: -40 F to +140 F (-40 C to +60 C)
Storage Temperature Range: -40 F to +158 F (-40 C to +70 C)

Components
Commercial
Weight: 6 lb (2.72 kg)
Includes: Mounting bracket, self-centering shaft adapter, 3mm crank
Comments: Integral 1/2 in. NPSM conduit connection.
Approvals:
CE: 89/336/ECC, 73/23/EEC
C-Tick: N314
Underwriters Laboratories, Inc. UL873, Plenum Rated
Pneumatic Controls

Canadian Underwriters Laboratories, Inc. cUL C22.2 No. 24-93

1/4 (6) 2-15/16 (75)


M20952
Industrial Combustion
Controls

70-6910 395
Direct Coupled Damper Actuators—Spring Return
Power
Timing (seconds) Consumption
Number
Nominal Maximum of Internal
Driving Spring Supply Input Auxiliary Switch
Product Number Control Signal Feedback @ 60 Hz Return (Driving) (Holding) Voltage Impedance Switch Ratings
MS4110A1002 Two position; SPST — 45 sec 20 sec 45 VA 13 VA 100 to 250 — 0 —
Vac
MS4110A1200 Two position; SPST — 45 sec 20 sec 45 VA 13 VA 100 to 250 — 2 250 Vac, 5 A
Vac res (3 A ind)
MS7510A2008 (0)2-10 Vdc (4-20 2-10 Vdc 90 sec 20 sec 14 VA 5 VA 24 Vac Min. 95 0 —
mA w/500 ohm (max. output: ±20% kOhm
resistor); Floating ±1.0 mA)
MS7510A2206 (0)2-10 Vdc (4-20 2-10 Vdc 90 sec 20 sec 14 VA 5 VA 24 Vac Min. 95 2 250 Vac, 5 A
mA w/500 ohm (max. output: ±20% kOhm res (3 A ind)
resistor); Floating ±1.0 mA)
MS7510H2209 (0)2-10 Vdc (4-20 2-10 Vdc 90 sec 20 sec 14 VA 5 VA 24 Vac Min. 95 2 250 Vac, 5 A
mA w/500 ohm (max. output: ±20% kOhm res (3 A ind)
resistor); Floating ±1.0 mA)
MS8110A1008 Two position; SPST — 45 sec 20 sec 30 VA 8 VA 24 Vac — 0 —
±20%
MS8110A1206 Two position; SPST — 45 sec 20 sec 30 VA 8 VA 24 Vac — 2 250 Vac, 5 A
±20% res (3 A ind)
Wiring for On/Off Control Wiring for Floating Control (Floating mode setting)

ACTUATOR

1 1
1 1 24 VAC
24 VAC SPST V 2 V
2 3
2 2

3 OR +

4 OR N/A

ACTUATOR 5 FEEDBACK

1 LINE VOLTAGE POWER SUPPLY. PROVIDE DISCONNECT MEANS 2-10 VDC


AND OVERLOAD PROTECTION AS REQUIRED. 10-2 VDC
1 LINE VOLTAGE POWER SUPPLY. 3 0-10 VDC
2 24 VDC SUPPLY ACCEPTABLE. PROVIDE DISCONNECT MEANS AND 10-0 VDC
OVERLOAD PROTECTION AS REQUIRED. Fltg, fwd
3 ENSURE PROPER GROUNDING OF ACTUATOR CASE. Fltg, rev
M19718C
2 24 VDC SUPPLY ACCEPTABLE.

3 SET SWITCH TO FLOATING.


M19573A
1
1 SPST 2 V Wiring for Proportioning controllers (Modulating mode setting)
2

ACTUATOR
1
1 24 VAC V
2
ACTUATOR 2

3 OR +
1 LINE VOLTAGE POWER SUPPLY. PROVIDE DISCONNECT MEANS 0/2 TO 10 VDC
AND OVERLOAD PROTECTION AS REQUIRED. PROPORTIONING 4 OR N/A
CONTROLLER
2 ENSURE PROPER GROUNDING OF ACTUATOR CASE. 5 FEEDBACK
M22289A

2-10 VDC
+ 10-2 VDC
3 0-10 VDC
FEEDBACK 10-0 VDC
Fltg, fwd
Fltg, rev
1 LINE VOLTAGE POWER SUPPLY.
PROVIDE DISCONNECT MEANS AND
OVERLOAD PROTECTION AS REQUIRED.

2 24 VDC SUPPLY ACCEPTABLE.

3 SET SWITCH TO MODULATING. M19574A

396 customer.honeywell.com 70-6910


Direct Coupled Damper Actuators—Spring Return
Wiring for Proportioning controllers (Modulating mode setting) Wiring for Proportioning controllers operating multiple actuators

Controls
Home
(Modulating mode setting)
ACTUATOR
1 1 24 VAC ACTUATOR
1 24 VAC V
2
2 2 1
V
3 OR + 2
4 TO 20 mA 1 24 VAC

Indoor Air Quality


500
PROPORTIONING 4 OR N/A 3 OR +
OHMS
CONTROLLER
5 FEEDBACK 0/2 TO 10 VDC 4 OR N/A
– PROPORTIONING
2-10 VDC CONTROLLER 5 FEEDBACK
+ 10-2 VDC
0-10 VDC HOT 2-10 VDC
3
FEEDBACK 10-0 VDC 10-2 VDC
Fltg, fwd COM 3 0-10 VDC
Fltg, rev 10-0 VDC
Fltg, fwd

Combustion Controls

1 LINE VOLTAGE POWER SUPPLY. Fltg, rev
PROVIDE DISCONNECT MEANS AND +

Residential
OVERLOAD PROTECTION AS REQUIRED.
ACTUATOR
2 24 VDC SUPPLY ACCEPTABLE.
1
3 SET SWITCH TO MODULATING. 1 24 VAC V
M22282 2
2
Override to full open (Modulating mode setting)
3 OR +

4 OR N/A
ACTUATOR

Hydronic Controls
1 5 FEEDBACK
1 24 VAC V
2
2 2-10 VDC
1 LINE VOLTAGE POWER SUPPLY. 10-2 VDC
3 OR + PROVIDE DISCONNECT MEANS AND 0-10 VDC
0/2 TO 10 VDC 3
PROPORTIONING OVERLOAD PROTECTION AS REQUIRED. 10-0 VDC
4 OR N/A
CONTROLLER Fltg, fwd
2 24 VDC SUPPLY ACCEPTABLE. Fltg, rev
5 FEEDBACK
– 3 SET SWITCH TO MODULATING. M22288
2-10 VDC
+ 10-2 VDC
SPDT Terminal Block Details
3 0-10 VDC

Controls
FEEDBACK 10-0 VDC

Water
Fltg, fwd
Fltg, rev ACTUATOR
7° 85° 3
1 LINE VOLTAGE POWER SUPPLY.

FEEDBACK
PROVIDE DISCONNECT MEANS AND
OVERLOAD PROTECTION AS REQUIRED.
V OR OR
2 24 VDC SUPPLY ACCEPTABLE. + N/A

Building Automation
3 SET SWITCH TO MODULATING. M19576A S1 S2 S3 S4 S5 S6 1 2 3 4 5
Override to full closed (Modulating mode setting)

ACTUATOR 2
1
1
1 24 VAC V
2
2 1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD
PROTECTION AS REQUIRED.
3 OR + 2 THE INTERNAL AUXILIARY SWITCHES MUST BE CONNECTED TO
0/2 TO 10 VDC
PROPORTIONING OR N/A THE SAME POWER SOURCE; OR THE AUXILIARY SWITCHES SHALL
4
BE CONNECTED TO THE SAME POLE OF THE SAME SUPPLY CIRCUIT,

Components
Commercial
CONTROLLER
5 FEEDBACK CONNECTED IN A SAME POLARITY MANNER.
– 3 ENSURE PROPER GROUNDING OF ACTUATOR CASE.
M19571B
2-10 VDC
+ 10-2 VDC
SPST 0-10 VDC
3
FEEDBACK 10-0 VDC
Fltg, fwd
Fltg, rev
Pneumatic Controls

1 LINE VOLTAGE POWER SUPPLY.


PROVIDE DISCONNECT MEANS AND
OVERLOAD PROTECTION AS REQUIRED.

2 24 VDC SUPPLY ACCEPTABLE.

3 SET SWITCH TO MODULATING. M19577A


Industrial Combustion
Controls

70-6910 397
Direct Coupled Damper Actuators—Spring Return
S20 Series: MS4120; MS7520; MS8120
Spring Return Direct Coupled Actuator, 175 lb-in
MS4120, MS7520, MS8120 Spring Return Direct Coupled Actuators
(DCA) are used within heating, ventilating, and air-conditioning
(HVAC) systems. They can drive a variety of quarter-turn, final
control elements requiring spring return fail-safe operation.
• Brushless DC submotor with electronic stall protection for floating/
modulating models.
• Brush DC submotor with electronic stall protection for 2-position
models.
• Self-centering shaft adapter (shaft coupling) for wide range of shaft
sizes.
• Models available for use with two-position, single pole single throw
(spst), line- (Series 40) or low- (Series 80) voltage controls.
• Models available for use with floating or switched single-pole,
double-throw (spdt) (Series 60) controls.
• Models available for use with proportional current or voltage (Series
70) controls.
• Models available with combined floating/modulating control in a
single device.
• Models available with adjustable zero and span.
• Models available with line-voltage internal end switches.
• Access cover to facilitate connectivity.
• Metal housing with built-in mechanical end limits.
• Spring return direction field-selectable.
• Shaft position indicator and scale.
• Manual winding capability with locking function.
• UL (cUL) listed and CE compliant.
• All models are plenum-rated per UL873.
Dimensions in inches (millimeters)
Actuator Type: Damper; Valve
3-15/16 (100) Rotational Stroke: 95 ±3 degrees
Fail Safe Mode: Spring Return
1-9/16 1-9/16
(40) (40) Torque: 175 lb-in. (20 Nm)
Spring Return Torque: 175 lb-in. (20 Nm)
Spring Return Direction: By orientation
External Auxiliary Switches Available: Yes, SW2-US
1-9/16
(40) Electrical Connections: Enclosed screw terminal strip (22 to 14 AWG)
Environmental Rating: NEMA2
Frequency: 50 Hz; 60 Hz
Manual operation: Manual crank
Mounting: Direct Coupled
Maximum Noise Rating, Holding (dBA @ 1m): 20 (no audible noise)
Maximum Noise Rating, Driving (dBA @ 1m): 40
Rotational Stroke Adjustment: Mechanically limited 5 degree
increments
9-3/4 Compatible Damper Shafts:
(247) 3/8 to 1.06 in. round or 3/8 to 11/16 in. square
(10 to 27 mm round or 10 to 18 mm square)
Shaft Adapter Type: Self-centering clamping
6-1/8 Materials: Aluminum housing, Plenum rated plastic access cover
(156)
Operating Humidity Range (% RH): 5 to 95% RH, non-condensing
Ambient Temperature Range: -40 F to +140 F (-40 C to +60 C)
Storage Temperature Range: -40 F to +158 F (-40 C to +70 C)
Weight: 6 lb (2.72 kg)
Includes: Mounting bracket, self-centering shaft adapter, 3mm crank
Comments: Integral 1/2 in. NPSM conduit connection.
Approvals:
CE: 89/336/ECC, 73/23/EEC
C-Tick: N314
Underwriters Laboratories, Inc. UL873, Plenum Rated
Canadian Underwriters Laboratories, Inc. cUL C22.2 No. 24-93

1/4 (6) 2-15/16 (75)


M20952

398 customer.honeywell.com 70-6910


Direct Coupled Damper Actuators—Spring Return

Controls
Home
Power
Timing (seconds) Consumption
Number
Nominal Maximum of Internal
Driving Spring Supply Input Auxiliary Switch
Product Number Control Signal Feedback @ 60 Hz Return (sec) (Driving) (Holding) Voltage Impedance Switch Ratings
MS4120A1001 Two position; SPST — 45 sec 20 sec 60 VA 13 VA 100 to — 0 —
250 Vac

Indoor Air Quality


MS4120A1209 Two position; SPST — 45 sec 20 sec 60 VA 13 VA 100 to — 2 250 Vac, 5 A
250 Vac res (3 A ind)
MS7520A2007 (0)2-10 Vdc (4-20 mA 2-10 Vdc 90 sec 20 sec 16 VA 5 VA 24 Vac Min. 95 0 —
w/500 ohm resistor); (max. output: ±20% kOhm
Floating ±1.0 mA)
MS7520A2205 (0)2-10 Vdc (4-20 mA 2-10 Vdc 90 sec 20 sec 16 VA 5 VA 24 Vac Min. 95 2 250 Vac, 5 A
w/500 ohm resistor); (max. output: ±20% kOhm res (3 A ind)
Floating ±1.0 mA)

Combustion Controls
MS7520H2208 (0)2-10 Vdc (4-20 mA 2-10 Vdc 90 sec 20 sec 16 VA 5 VA 24 Vac Min. 95 2 250 Vac, 5 A

Residential
w/500 ohm resistor); (max. output: ±20% kOhm res (3 A ind)
Floating ±1.0 mA)
MS8120A1007 Two position; SPST — 45 sec 20 sec 40 VA 8 VA 24 Vac — 0 —
±20%
MS8120A1205 Two position; SPST — 45 sec 20 sec 40 VA 8 VA 24 Vac — 2 250 Vac, 5 A
±20% res (3 A ind)
Wiring for On/Off Control Wiring for Proportioning Controllers (Modulating mode setting)

Hydronic Controls
ACTUATOR

1 1
1 1 24 VAC V
24 VAC SPST V 2
2 3 2
2
3 OR +
0/2 TO 10 VDC
PROPORTIONING 4 OR N/A
CONTROLLER
ACTUATOR 5 FEEDBACK

Controls
1 LINE VOLTAGE POWER SUPPLY. PROVIDE DISCONNECT MEANS 2-10 VDC

Water
AND OVERLOAD PROTECTION AS REQUIRED. + 10-2 VDC
3 0-10 VDC
2 24 VDC SUPPLY ACCEPTABLE. FEEDBACK 10-0 VDC
Fltg, fwd
3 ENSURE PROPER GROUNDING OF ACTUATOR CASE. Fltg, rev
M19718C
1 LINE VOLTAGE POWER SUPPLY.
PROVIDE DISCONNECT MEANS AND

Building Automation
OVERLOAD PROTECTION AS REQUIRED.
1
1 SPST 2 V 2 24 VDC SUPPLY ACCEPTABLE.
2
3 SET SWITCH TO MODULATING. M19574A

ACTUATOR
1
1 24 VAC V
ACTUATOR 2
2
1 LINE VOLTAGE POWER SUPPLY. PROVIDE DISCONNECT MEANS 3 OR +
AND OVERLOAD PROTECTION AS REQUIRED. 4 TO 20 mA
500
PROPORTIONING

Components
OR N/A

Commercial
OHMS 4
2 ENSURE PROPER GROUNDING OF ACTUATOR CASE. CONTROLLER
M22289A
5 FEEDBACK
Wiring for Floating Control (Floating mode setting) –
2-10 VDC
+ 10-2 VDC
ACTUATOR 3 0-10 VDC
FEEDBACK 10-0 VDC
1
1 24 VAC Fltg, fwd
2 V
2 Fltg, rev
Pneumatic Controls

1 LINE VOLTAGE POWER SUPPLY.


3 OR +
PROVIDE DISCONNECT MEANS AND
OR N/A OVERLOAD PROTECTION AS REQUIRED.
4

5 FEEDBACK 2 24 VDC SUPPLY ACCEPTABLE.

3 SET SWITCH TO MODULATING. M22282


2-10 VDC
10-2 VDC
1 LINE VOLTAGE POWER SUPPLY. 3 0-10 VDC
PROVIDE DISCONNECT MEANS AND 10-0 VDC
Industrial Combustion

OVERLOAD PROTECTION AS REQUIRED. Fltg, fwd


Fltg, rev
2 24 VDC SUPPLY ACCEPTABLE.
Controls

3 SET SWITCH TO FLOATING.


M19573A

70-6910 399
Direct Coupled Damper Actuators—Spring Return
Override to full open (Modulating mode setting) Wiring for Proportioning controllers operating multiple actuators
(Modulating mode setting)
ACTUATOR
1 1 24 VAC ACTUATOR
1 24 VAC V
2 2
2 1
V
3 OR + 2
0/2 TO 10 VDC 1 24 VAC
PROPORTIONING 4 OR N/A 3 OR +
CONTROLLER
5 FEEDBACK 0/2 TO 10 VDC 4 OR N/A
– PROPORTIONING
CONTROLLER 5 FEEDBACK
2-10 VDC
+ 10-2 VDC
SPDT 0-10 VDC HOT 2-10 VDC
3 10-2 VDC
FEEDBACK 10-0 VDC
Fltg, fwd COM 3 0-10 VDC
Fltg, rev 10-0 VDC
– Fltg, fwd
1 LINE VOLTAGE POWER SUPPLY. Fltg, rev
PROVIDE DISCONNECT MEANS AND +
OVERLOAD PROTECTION AS REQUIRED.
ACTUATOR
2 24 VDC SUPPLY ACCEPTABLE.
1
3 SET SWITCH TO MODULATING. 1 24 VAC V
M19576A 2
2
Override to full closed (Modulating mode setting) 3 OR +

4 OR N/A
ACTUATOR
1 5 FEEDBACK
1 24 VAC V
2
2 2-10 VDC
1 LINE VOLTAGE POWER SUPPLY. 10-2 VDC
3 OR + PROVIDE DISCONNECT MEANS AND 0-10 VDC
0/2 TO 10 VDC 3
PROPORTIONING OR N/A OVERLOAD PROTECTION AS REQUIRED. 10-0 VDC
4
CONTROLLER Fltg, fwd
FEEDBACK 2 24 VDC SUPPLY ACCEPTABLE. Fltg, rev
5
– 3 SET SWITCH TO MODULATING. M22288
2-10 VDC
+ 10-2 VDC Terminal Block Details
SPST 0-10 VDC
3
FEEDBACK 10-0 VDC
Fltg, fwd ACTUATOR
Fltg, rev 7° 85° 3

FEEDBACK
1 LINE VOLTAGE POWER SUPPLY.
PROVIDE DISCONNECT MEANS AND
OVERLOAD PROTECTION AS REQUIRED. V OR OR
+ N/A
2 24 VDC SUPPLY ACCEPTABLE.

3 SET SWITCH TO MODULATING. S1 S2 S3 S4 S5 S6 1 2 3 4 5


M19577A

2
1

1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD


PROTECTION AS REQUIRED.
2 THE INTERNAL AUXILIARY SWITCHES MUST BE CONNECTED TO
THE SAME POWER SOURCE; OR THE AUXILIARY SWITCHES SHALL
BE CONNECTED TO THE SAME POLE OF THE SAME SUPPLY CIRCUIT,
CONNECTED IN A SAME POLARITY MANNER.
3 ENSURE PROPER GROUNDING OF ACTUATOR CASE.
M19571B

400 customer.honeywell.com 70-6910


Direct Coupled Damper Actuators—Spring Return
ML4135; ML8135

Controls
Home
HVAC, Fast-Acting, Two-Position Actuators, 40 lb-in
The ML8135 Fast-Acting, Two-Position Actuators are spring return
direct coupled actuators (DCA) with an integral junction box for on/
off damper control.
• Integral spring return.
• -40 C to 130 F (-40 C to 54 C) operating temperature range.

Indoor Air Quality


• No audible noise during holding.
• Electronic circuitry provides efficient operation while eliminating the
need for limit switches.
• Ninety-five degree angle of rotation.
• Die-cast aluminum housing. Housing design allows flush mounting
to damper.
• Integral junction box with three conduit openings eliminates need for
separate wiring box.
• Direct mounting to 3/8 or 1/2 in. round or square shaft.

Combustion Controls
• Not intended for smoke control systems.

Residential
Hydronic Controls
Dimensions in inches (millimeters)
Actuator Type: Damper
2 (51) Rotational Stroke: 95 ±3 degrees
1 (25) Fail Safe Mode: Spring Return
Torque: 40 lb-in. (4.5 Nm)
5/8
Spring Return Torque: 40 lb-in. (4.5 Nm)
(17)
1
External Auxiliary Switches Available: Yes, 32003532-005
Electrical Connections: Two color-coded leads
Electrical Connection Length: 16 in. (406 mm)
6 3/8 Environmental Rating: NEMA1
(161)
Frequency: 60 Hz

Controls
Mounting: Direct Coupled

Water
Maximum Noise Rating, Holding (dBA @ 1m): 20 (no audible noise)
Maximum Noise Rating, Driving (dBA @ 1m): 65
Compatible Damper Shafts: 3/8 to 1/2 in. square or round
(10 to 13 mm square/round)
7 1/2
(192) Shaft Adapter Type: Aluminum Hub, four set screws
Materials: Aluminum housing
Operating Humidity Range (% RH): 5 to 95% RH, non-condensing

Building Automation
Ambient Temperature Range: -40 F to +130 F (-18 C to +55 C)
Storage Temperature Range: -40 F to +140 F (-18 C to +60 C)
Weight: 6 lb (2.72 kg)
Comments: Integral junction box with three 7/8 in. conduit openings
2 (51) 3 5/16 (84) (fittings not included)
4 (102) 1/16 (2) Approvals:
Underwriters Laboratories, Inc. UL873, Plenum Rated
7/8 (22) Canadian Underwriters Laboratories, Inc. cUL C22.2 No. 24-93

Components
Commercial
1 ML4135/ML8135 HAVE SHORTER
HUB WITH TWO SET SCREWS.
ML4125/ML8125 HAVE LONGER
HUB WITH FOUR SET SCREWS.

5 1/8 (129) M17538


Pneumatic Controls
Industrial Combustion
Controls

70-6910 401
Direct Coupled Damper Actuators—Spring Return
Timing (seconds) Power Consumption
Number
Spring Maximum Nominal Maximum of Internal
Control Return Driving Driving Spring Supply Auxiliary
Product Number Signal Direction @ 60 Hz @ 60 Hz Return (Driving) (Holding) Voltage Switch Includes
ML4135A1007 Two position; CCW 25 sec 20 sec 15 sec 0.18A, 18W 0.11A, 9W 120 Vac ±10% 0 Mounting
SPST bracket,
ground screw
ML4135B1006 Two position; CW 25 sec 20 sec 15 sec 0.18A, 18W 0.11A, 9W 120 Vac ±10% 0 Mounting
SPST bracket,
ground screw
ML8135A1003 Two position; CCW 25 sec 20 sec 15 sec 18 VA 8.5 VA 24 Vac +20%, 0 Mounting
SPST -10% bracket
ML8135B1002 Two position; CW 25 sec 20 sec 15 sec 18 VA 8.5 VA 24 Vac +20%, 0 Mounting
SPST -10% bracket
Typical 24 Vac wiring Typical 120 Vac Wiring

L1 ( )
L1 ( )
RED BLACK
24 VAC BLACK 120 VAC WHITE
L2 ( )
L2 ( )

M17585A M17589A

Typical 230 Vac Wiring

L1 ( )
BROWN
230 VAC BLUE
L2 ( )

M17588A

402 customer.honeywell.com 70-6910


Direct Coupled Damper Actuators—Spring Return
ML4125; ML8125;

Controls
Home
HVAC, Fast-Acting, Two-Position Actuators, 100 lb-in
The ML8125 Fast-Acting, Two-Position Actuators are spring return
direct coupled actuators (DCA) with an integral junction box for on/
off damper control.
• Integral spring return.
• -40 C to 130 F (-40 C to 54 C) operating temperature range.

Indoor Air Quality


• No audible noise during holding.
• Electronic circuitry provides efficient operation while eliminating the
need for limit switches.
• Ninety-five degree angle of rotation.
• Die-cast aluminum housing. Housing design allows flush mounting
to damper.
• Integral junction box with three conduit openings eliminates need for
separate wiring box.
• Direct mounting to 3/8 or 1/2 in. round or square shaft.

Combustion Controls
• Not intended for smoke control systems.

Residential
Hydronic Controls
Dimensions in inches (millimeters) Actuator Type: Damper
Rotational Stroke: 95 ±3 degrees
2 (51) Fail Safe Mode: Spring Return
1 (25) Torque: 100 lb-in. (11.3 Nm)
Spring Return Torque: 100 lb-in. (11.3 Nm)
5/8 External Auxiliary Switches Available: Yes, 32003532-005
(17)
1 Electrical Connections: Two color-coded leads
Electrical Connection Length: 16 in. (406 mm)
Environmental Rating: NEMA1
6 3/8
(161)
Frequency: 60 Hz
Mounting: Direct Coupled

Controls
Maximum Noise Rating, Holding (dBA @ 1m): 20 (no audible noise)

Water
Maximum Noise Rating, Driving (dBA @ 1m): 65
Compatible Damper Shafts: 3/8 to 1/2 in. square or round
(10 to 13 mm square/round)
7 1/2
Shaft Adapter Type: Aluminum Hub, two set screws
(192) Materials: Aluminum housing
Operating Humidity Range (% RH): 5 to 95% RH, non-condensing

Building Automation
Ambient Temperature Range: -40 F to +130 F (-18 C to +55 C)
Storage Temperature Range: -40 F to 140 F (-40 C to +60 C)
Weight: 6 lb (2.72 kg)
Comments: Integral junction box with three 7/8 in. conduit openings
(fittings not included)
2 (51) 3 5/16 (84)
4 (102)
Approvals:
1/16 (2) Underwriters Laboratories, Inc. UL873, Plenum Rated
Canadian Underwriters Laboratories, Inc. cUL C22.2 No. 24-93
7/8 (22)

Components
Commercial
1 ML4135/ML8135 HAVE SHORTER
HUB WITH TWO SET SCREWS.
ML4125/ML8125 HAVE LONGER
HUB WITH FOUR SET SCREWS.

5 1/8 (129) M17538


Pneumatic Controls
Industrial Combustion
Controls

70-6910 403
Direct Coupled Damper Actuators—Spring Return
Timing (seconds) Power Consumption
Number of
Spring Maximum Nominal Maximum Internal
Return Driving @ Driving Spring Supply Auxiliary
Product Number Control Signal Direction 60 Hz @ 60 Hz Return (Driving) (Holding) Voltage Switch Includes
ML4125A1008 Two position; CCW 40 sec 25 sec 25 sec 0.16A, 15W 0.10A, 5W 120 Vac +10%, 0 Ground
SPST -15% Screw
ML4125B1007 Two position; CW 40 sec 25 sec 25 sec 0.16A, 15W 0.10A, 5W 120 Vac +10%, 0 Ground
SPST -15% Screw
ML4125C1006 Two position; CCW 40 sec 25 sec 25 sec 0.12A, 18.6W 0.10A, 7W 230 Vac ±10% 0 Mounting
SPST bracket
ML4125D1005 Two position; CW 40 sec 25 sec 25 sec 0.12A, 18.6W 0.10A, 7W 230 Vac ±10% 0 Mounting
SPST bracket
ML8125A1004 Two position; CCW 40 sec 25 sec 25 sec 15.6 VA 4 VA 24 Vac +20%, 0 Mounting
SPST -10% bracket
ML8125B1003 Two position; CW 40 sec 25 sec 25 sec 15.6 VA 4 VA 24 Vac +20%, 0 Mounting
SPST -10% bracket

Typical 24 Vac wiring Typical 230 Vac Wiring

L1 ( )
L1 ( )
RED BROWN
24 VAC BLACK 230 VAC BLUE

L2 ( ) L2 ( )

M17585A M17588A

Typical 120 Vac Wiring

L1 ( )
BLACK
120 VAC WHITE
L2 ( )

M17589A

404 customer.honeywell.com 70-6910


Direct Coupled Damper Actuators—Non-Spring Return
ML6161; ML7161

Controls
Home
Non-Spring Return Direct Coupled Damper Actuators, 35 lb-in
Used to control dampers in applications such as variable air
volume (VAV) terminal units and for mounting on ball valves;
suitable for use with SPDT or floating thermostats or building
automation controls.
• Control for air damper applications with up to 10 sq.ft. assuming 3.5

Indoor Air Quality


in-lb per sq.ft. of damper area, velocity independent.
• Superior A/C synchronous submotor for consistent timing and
actuator longevity.
• Eliminate need for limit switches or mechanical stops by providing
magnetic coupling.
• All models include manual declutch lever, and bag assembly with
two minimum position setscrews.
• Mount directly on 3/8 inch or 1/2 inch square or round damper shaft.
• Selectable 45, 60, and 90 stroke in either clockwise or

Combustion Controls
ML6161A,B ML6161C,D counterclockwise direction.
ML7161

Residential
Actuator Type: Damper Compatible Damper Shafts: 3/8 to 1/2 in. square or round
Rotational Stroke: 90 degrees (10 to 13 mm square/round)
Fail Safe Mode: Non-Spring Return Shaft Adapter Type: Aluminum Hub, two set screws
Torque: 35 lb-in. (4 Nm) Supply Voltage: 24 Vac ±20%
External Auxiliary Switches Available: Yes, 201052B Materials: Steel plate and Plenum rated plastic
Electrical Connections: Screw terminals Operating Humidity Range (% RH): 5 to 95% RH, non-condensing
Environmental Rating: NEMA1 Ambient Temperature Range: 20 F to 125 F (-18 C to +50 C)

Hydronic Controls
Feedback: With accessory Storage Temperature Range: 20 F to 130 F (-18 C to +54 C)
Frequency: 50 Hz; 60 Hz Weight: 1.5 lb (0.68 kg)
Manual operation: Declutch mechanism Includes: 4074ENY Bag Assembly
Mounting: Direct Coupled Approvals:
Maximum Noise Rating, Driving (dBA @ 1m): 45 CE: 89/336/ECC, 73/23/EEC
Rotation to Open: By wiring C-Tick: N314
Rotational Stroke Adjustment: Mechanically limited at 45 or 60 Underwriters Laboratories, Inc. UL873, Plenum Rated
degrees in cw or ccw directions Canadian Underwriters Laboratories, Inc. cUL C22.2 No. 24-93

Timing

Controls
Number of

Water
(seconds)
Power Internal
Nominal Driving Consumption Auxiliary
Product Number Control Signal Feedback @ 60 Hz (Driving) Input Impedance Switch Comments
* ML6161A2009 SPDT; Floating With accessory 90 sec 1.8 VA — 0 —
ML6161A2017 SPDT; Floating With accessory 420 sec 1.8 VA — 0 —

Building Automation
* ML6161A2025 SPDT; Floating With accessory 180 sec 1.8 VA — 0 —
* ML6161B2024 SPDT; Floating — 90 sec 1.8 VA — 0 —
* ML6161B2032 SPDT; Floating — 420 sec 1.8 VA — 0 —
* ML6161B2073 SPDT; Floating — 180 sec 1.8 VA — 0 —
ML6161C2007 SPDT; Floating With accessory 90 sec 1.8 VA — 0 Includes two 5/8 x
7/8 in. double
knock-out conduit
openings
ML6161D2006 SPDT; Floating — 90 sec 1.8 VA — 0 Includes two 5/8 x

Components
7/8 in. double

Commercial
knock-out conduit
openings
ML7161A2008 2 to 10 Vdc (4-20 mA — 90 sec 5.4 VA 45K ohm (2-10 Vdc 0 —
w/500 ohm resistor) signal), 536 ohm (4-
20 mA signal)
* TRADELINE models • SUPER TRADELINE models
Pneumatic Controls
Industrial Combustion
Controls

70-6910 405
Direct Coupled Damper Actuators—Non-Spring Return
ML6161A,B Dimensions in inches (millimeters) ML6161 Dimensions in inches (millimeters)

2-7/8 (73) 2-7/8 (73)


1-11/16
1-11/16 (42)
(42)
1 OPTIONAL
(25) AUXILIARY
SWITCH 1/8
1 (25) 1/8 (3)
OPTIONAL
AUXILIARY (3)
SWITCH

5-9/16
(141)
4-7/8
4-7/8 24 Vac (123)
CW (123) T1 4-1/4
COM T2 (108)
4-1/4 -
CCW (108) +
+
2-10 Vdc
4-20 mA

15/32 (12) 11/16 1/8


(18) (3)
1/8 1-5/16
(3) (33)
5/16 (8)
11/16 1-11/16 3 (76)
(18) (43)
7/8
(22) 3-3/8 (86) M22990
1-5/16
3-3/8 (86) (33)
2-1/2 (64)
M18016

ML6161C,D Dimensions in inches (millimeters)

1-13/16
(46) 3-5/8 (92)

1 (25)
3 IN. (76 MM)
MINIMUM
SPACING 1-13/16
REQUIRED FOR (46)
REMOVING
CONDUIT
COVER

5-7/8
(149)

7/8
(22)

3-3/4 (95) M18018A

406 customer.honeywell.com 70-6910


Direct Coupled Damper Actuators—Non-Spring Return
Typical Wiring of ML6161 using Electronic Floating T6984 ML7161 used with 4-20 mA control

Controls
Home
Thermostat
1 ML7161, ML7174
ML6161, ML6174 L1
(HOT) T1
CW L2
T2
L1 COM
– –

Indoor Air Quality


(HOT)
24 VAC
L2 CCW + + mA
1
+V
COMMON

24 VAC 4-20 mA CONTROLLER

MOTOR CLOSE 1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD


PROTECTION AS REQUIRED.

Combustion Controls
M18071
MOTOR OPEN
ML7161 used with 2-10 Vdc control

Residential
T6984A 2

1 ML7161, ML7174
1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND L1
OVERLOAD PROTECTION, AS REQUIRED. (HOT) T1
2 T6984A SHOWN WIRED FOR COOLING ONLY. TO WIRE FOR L2
HEATING ONLY, REVERSE OPEN AND CLOSE CONTACTS. T2
M18023
– –

Hydronic Controls
+ + mA

+V

2-10 Vdc CONTROLLER

1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD


PROTECTION AS REQUIRED.
M18072

Controls
Water
Building Automation
Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 407
Direct Coupled Damper Actuators—Non-Spring Return
ML6174; ML7174,
Non-Spring Return Direct Coupled Damper Actuators, 70 lb-in
Used to control dampers in applications such as variable air
volume (VAV) terminal units and for mounting on ball valves;
suitable for use with SPDT or floating thermostats or building
automation controls.
• Control for air damper applications with up to 20 sq.ft. assuming 3.5
in-lb per sq.ft. of damper area, velocity independent.
• Magnetic coupling eliminates the need for mechanical stops or limit
switch adjustments by limiting stall torque to 130 lb-in. maximum.
• Mount directly on 3/8 to 1/2 in. round and square damper shafts. All
models include manual declutch lever for ease of mounting, and bag
assembly with two minimum position setscrews. 90 second timing
models are suitable for use with pressure independent VAV systems.
• Selectable 45, 60, and 90 degree stroke in either clockwise or
counterclockwise direction.
ML6174A,B ML6174C,D ML6174

Actuator Type: Damper Compatible Damper Shafts: 3/8 to 1/2 in. square or round
Rotational Stroke: 90 degrees (10 to 13 mm square/round)
Fail Safe Mode: Non-Spring Return Shaft Adapter Type: Aluminum Hub, two set screws
Torque: 70 lb-in (8 Nm) Supply Voltage: 24 Vac ±20%
External Auxiliary Switches Available: Yes, 201052B Materials: Steel plate and Plenum rated plastic
Environmental Rating: NEMA1 Operating Humidity Range (% RH): 5 to 95% RH, non-condensing
Feedback: With accessory Ambient Temperature Range: 20 F to 125 F (-18 C to +50 C)
Frequency: 50 Hz; 60 Hz Storage Temperature Range: 20 F to 130 F (-18 C to +54 C)
Manual operation: Declutch mechanism Weight: 1.5 lb (0.68 kg)
Mounting: Direct Coupled Includes: 4074ENY Bag Assembly
Maximum Noise Rating, Driving (dBA @ 1m): 45 Approvals:
Rotation to Open: By wiring Underwriters Laboratories, Inc. UL873, Plenum Rated
Rotational Stroke Adjustment: Mechanically limited at 45 or 60 Canadian Underwriters Laboratories, Inc. cUL C22.2 No. 24-93
degrees in cw or ccw directions

Electrical
Timing Connection
(seconds) Number Length
of
Spring Nominal Power Internal
Return Driving @ Consumption Input Auxiliary Electrical
Product Number Control Signal Feedback Direction 60 Hz (Driving) Impedance Switch Connections (inch) (m) Comments
* ML6174A2002 SPDT; Floating With — 90 sec 2.4 VA — 0 Screw — — —
accessory terminals
* ML6174A2010 SPDT; Floating With — 180 sec 2.4 VA — 0 Screw — — —
accessory terminals
* ML6174B2019 SPDT; Floating — — 90 sec 2.4 VA — 0 Screw — — —
terminals
ML6174B2035 SPDT; Floating — — 420 sec 2.4 VA — 0 Screw — — —
terminals
ML6174D2009 SPDT; Floating — — 90 sec 2.4 VA — 0 Screw — — Includes two
terminals 5/8 x 7/8 in.
double knock-
out conduit
openings
ML6174E2008 SPDT; Floating — — 90 sec 2.4 VA — 0 Appliance 39 in. 1 m —
cable
ML7174A2001 2 to 10 Vdc — Stem 90 sec 5.4 VA 45K ohm (2- 0 Screw — — —
(4-20 mA w/500 down on 10 Vdc terminals
ohm resistor) power signal), 536
failure ohm (4-20 mA
signal)
ML7174E2007 2 to 10 Vdc — — 90 sec 5.4 VA 45K ohm (2- 0 Appliance 39 in. 1 m —
(4-20 mA w/500 10 Vdc cable
ohm resistor) signal), 536
ohm (4-20 mA
signal)
* TRADELINE models • SUPER TRADELINE models

408 customer.honeywell.com 70-6910


Direct Coupled Damper Actuators—Non-Spring Return
ML6174A,B Dimensions in inches (millimeters) ML6174 Dimensions in inches (millimeters)

Controls
Home
2-7/8 (73) 2-7/8 (73)
1-11/16
1-11/16 (42)
(42)
1 OPTIONAL
(25) AUXILIARY
SWITCH 1/8
1 (25) 1/8 (3)
OPTIONAL

Indoor Air Quality


AUXILIARY (3)
SWITCH
5-9/16
(141)
4-7/8
4-7/8 24 Vac (123)
CW (123) T1 4-1/4
T2 (108)
COM -
4-1/4
(108) +
CCW +

Combustion Controls
2-10 Vdc
4-20 mA

Residential
15/32 (12) 11/16 1/8
(18) (3)
1/8 1-5/16
(3) (33)
5/16 (8)
1-11/16 3 (76)
11/16 (43)
(18) 7/8 M22990
3-3/8 (86)
(22)
1-5/16

Hydronic Controls
3-3/8 (86) (33)
2-1/2 (64)
M18016

ML6174C,D Dimensions in inches (millimeters)

1-13/16
(46) 3-5/8 (92)

1 (25)
3 IN. (76 MM)
MINIMUM

Controls
1-13/16

Water
SPACING
REQUIRED FOR (46)
REMOVING
CONDUIT
COVER

5-7/8

Building Automation
(149)

7/8
(22)

3-3/4 (95) M18018A

Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 409
Direct Coupled Damper Actuators—Non-Spring Return
Typical Wiring of ML6174 using Electronic Floating T6984 ML7174 used with 4-20 mA control
Thermostat
1 ML7161, ML7174
ML6161, ML6174 L1
(HOT) T1
CW
L2
T2
L1 COM
(HOT) – –
24 VAC
L2 CCW + + mA
1
+V
COMMON

24 VAC 4-20 mA CONTROLLER

MOTOR CLOSE 1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD


PROTECTION AS REQUIRED.
M18071
MOTOR OPEN
ML7174 used with 2-10 Vdc control
T6984A 2

1 ML7161, ML7174
1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND L1
OVERLOAD PROTECTION, AS REQUIRED. (HOT) T1
2 T6984A SHOWN WIRED FOR COOLING ONLY. TO WIRE FOR L2
HEATING ONLY, REVERSE OPEN AND CLOSE CONTACTS. T2
M18023
– –

+ + mA

+V

2-10 Vdc CONTROLLER

1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD


PROTECTION AS REQUIRED.
M18072

410 customer.honeywell.com 70-6910


Direct Coupled Damper Actuators—Non-Spring Return
N05 Series: MN6105; MN7505

Controls
Home
Non-Spring Return Direct Coupled Actuator, 44 lb-in
This non-spring return direct-coupled damper actuator provides
modulating and floating/2-position control for: air dampers, air
handlers, ventilation flaps, louvers, and reliable control for air
damper applications with up to 10 sq. ft./ 44lb.-in. (5 Nm) and 20 sq.
ft./88 lb.-in. (10 Nm) (seal-less damper blades; air friction-

Indoor Air Quality


dependent).
• Declutch for manual adjustment
• Adjustable mechanical end limits
• Removable access cover for direct wiring
• Mountable in any orientation
• Function selection switch for selecting modulating or floating/2-
position control

Combustion Controls
Residential
Hydronic Controls
Dimensions in inches (millimeters) Actuator Type: Damper; Valve
Rotational Stroke: 95 ±3 degrees
1-5/8 Fail Safe Mode: Non-Spring Return
(41) Torque: 44 lb-in. (5 Nm)
External Auxiliary Switches Available: Yes, SSW2-1M
Electrical Connections: Enclosed screw terminal strip (22 to 14 AWG)
Environmental Rating: NEMA2
Frequency: 50 Hz; 60 Hz
Manual operation: Declutch mechanism

Controls
Mounting: Direct Coupled

Water
3-11/32
(85)
Maximum Noise Rating, Driving (dBA @ 1m): 35
Rotation to Open: By switch
4-1/4 Rotational Stroke Adjustment: Dual Integral Adj. Stops (3 degree
5-9/32 (108) increments)
(134)
Compatible Damper Shafts: 1/4 to 1/2 in. square or 3/8 to 5/8 in. round
(6 to 13 mm square or 8 to 16 mm round)
Shaft Adapter Type: U-bolt clamp

Building Automation
Supply Voltage: 24 Vac +20%, -15%, 24 Vdc
Materials: Plenum rated plastic housing
Ingress Protection Rating: IP54
Operating Humidity Range (% RH): 5 to 95% RH, non-condensing
2-7/16 2-19/32
(62) (66) M23103A Ambient Temperature Range: -5 F to +140 F (-20 C to +60 C)
Storage Temperature Range: -22 F to +176 F (-30 C to +80 C)
Weight: 1 lb (0.45 kg)
Includes: Mounting bracket, screws, shaft adapter, water-tight strain-
relief cable fittings
Comments: Integral 1/2 in. NPSM conduit connection.

Components
Commercial
Approvals:
CE: 89/336/ECC, 73/23/EEC
C-Tick: N314
Underwriters Laboratories, Inc. UL873, Plenum Rated
Canadian Underwriters Laboratories, Inc. cUL C22.2 No. 24-93

Timing (seconds) Number of


Power Internal
Pneumatic Controls

Nominal Driving Consumption Auxiliary Switch


Product Number Control Signal Feedback @ 60 Hz (Driving) Switch Ratings
* MN6105A1011 Floating; Two position — 95 sec 5 VA 0 —
* MN6105A1201 Floating; Two position — 95 sec 5 VA 2 30 Vdc max.,
3 A Class II
* MN7505A2001 (0)2-10 Vdc (4-20 mA w/500 ohm resistor); (0)2-10 Vdc (max. 95 sec 5 VA 0 —
Floating; Two position output: ±1.0 mA)
Industrial Combustion

* MN7505A2209 (0)2-10 Vdc (4-20 mA w/500 ohm resistor); (0)2-10 Vdc (max. 95 sec 5 VA 2 30 Vdc max.,
Floating; Two position output: ±1.0 mA) 3 A Class II
Controls

* TRADELINE models • SUPER TRADELINE models

70-6910 411
Direct Coupled Damper Actuators—Non-Spring Return
Wiring for Floating Control Wiring for Voltage Control

MN6105, MN6110 MN7505, MN7510


FLOATING: DIR MODULATING: 0[2]... 10 V, 10... 0[2] V
ACTUATOR
ACTUATOR
1
V 1
2 V
1 24 VAC 2
2 1 24 VAC
3 2
0[2]... 10 V 3 OR +
4
4 POS 50%
5
0[2]... 10 V 5 FEEDBACK
1 LINE VOLTAGE POWER SUPPLY. 2... 10 V
PROVIDE DISCONNECT MEANS AND Dir = OVERRIDE OPTION 0... 10 V
OVERLOAD PROTECTION AS REQUIRED. Service/Off Dir
Rev 1 LINE VOLTAGE POWER SUPPLY. Service/Off
2 24 VDC SUPPLY ACCEPTABLE. PROVIDE DISCONNECT MEANS AND Rev
OVERLOAD PROTECTION AS REQUIRED. 10... 0 V
M23107
10... 2 V
2 24 VDC SUPPLY ACCEPTABLE.
M23097

Wiring for Auxiliary Switches

END SWITCHES (CLASS II-ONLY)

5° 85°

S1 S2 S3 S5 S6

M23110

412 customer.honeywell.com 70-6910


Direct Coupled Damper Actuators—Non-Spring Return
N10 Series: MN6110; MN7510

Controls
Home
Non-Spring Return Direct Coupled Actuator, 88 lb-in
This non-spring return direct-coupled damper actuator provides
modulating and floating/2-position control for air dampers, air
handlers, ventilation flaps, louvers, and reliable control for air
damper applications with up to 20 sq ft/88 lb-in. (10 Nm) (seal-less
damper blades; air friction-dependent).

Indoor Air Quality


• Declutch for manual adjustment
• Adjustable mechanical end limits
• Removable access cover for direct wiring
• Mountable in any orientation
• Function selection switch for selecting modulating or floating/2-
position control

Combustion Controls
Residential
Hydronic Controls
Dimensions in inches (millimeters) Actuator Type: Damper; Valve
Rotational Stroke: 95 ±3 degrees
1-5/8 Fail Safe Mode: Non-Spring Return
(41) Torque: 88 lb-in. (10 Nm)
External Auxiliary Switches Available: Yes, SSW2-1M
Electrical Connections: Enclosed screw terminal strip (22 to 14 AWG)
Environmental Rating: NEMA2
Frequency: 50 Hz; 60 Hz
Manual operation: Declutch mechanism
Mounting: Direct Coupled

Controls
Water
3-11/32
(85)
Maximum Noise Rating, Driving (dBA @ 1m): 35
Rotation to Open: By switch
4-1/4 Rotational Stroke Adjustment: Dual Integral Adj. Stops (3 degree
5-9/32 (108) increments)
(134)
Compatible Damper Shafts: 1/4 to 1/2 in. square or 3/8 to 5/8 in. round
(6 to 13 mm square or 8 to 16 mm round)
Shaft Adapter Type: U-bolt clamp

Building Automation
Supply Voltage: 24 Vac +20%, -15%, 24 Vdc
Materials: Plenum rated plastic housing
Ingress Protection Rating: IP54
Operating Humidity Range (% RH): 5 to 95% RH, non-condensing
2-7/16 2-19/32
(62) (66) M23103A Ambient Temperature Range: -5 F to +140 F (-20 C to +60 C)
Storage Temperature Range: -22 F to +176 F (-30 C to +80 C)
Weight: 1 lb (0.45 kg)
Includes: Mounting bracket, screws, shaft adapter, water-tight strain-
relief cable fittings
Comments: Integral 1/2 in. NPSM conduit connection.

Components
Commercial
Approvals:
CE: 89/336/ECC, 73/23/EEC
C-Tick: N314
Underwriters Laboratories, Inc. UL873, Plenum Rated
Canadian Underwriters Laboratories, Inc. cUL C22.2 No. 24-93

Timing (seconds) Number


of Internal
Pneumatic Controls

Nominal Driving Power Consumption Auxiliary


Product Number Control Signal Feedback @ 60 Hz (Driving) Switch Switch Ratings
* MN6110A1003 Floating; Two position — 95 sec 5 VA 0 —
* MN6110A1201 Floating; Two position — 95 sec 5 VA 2 30 Vdc max.,
3 A Class II
* MN7510A2001 (0)2-10 Vdc (4-20 mA w/500 ohm (0)2-10 Vdc (max. 95 sec 5 VA 0 —
resistor); Floating; Two position output: ±1.0 mA)
* MN7510A2209 (0)2-10 Vdc (4-20 mA w/500 ohm (0)2-10 Vdc (max. 95 sec 5 VA 2 30 Vdc max.,
Industrial Combustion

resistor); Floating; Two position output: ±1.0 mA) 3 A Class II


* TRADELINE models • SUPER TRADELINE models
Controls

70-6910 413
Direct Coupled Damper Actuators—Non-Spring Return
Wiring for Floating Control Wiring for Voltage Control

MN6105, MN6110 MN7505, MN7510


FLOATING: DIR MODULATING: 0[2]... 10 V, 10... 0[2] V
ACTUATOR ACTUATOR
1 1
V V
2 2
1 24 VAC 1
2 24 VAC
3 2 OR +
0[2]... 10 V 3
4 4 POS 50%
5 0[2]... 10 V 5 FEEDBACK
2... 10 V
1 LINE VOLTAGE POWER SUPPLY.
= OVERRIDE OPTION 0... 10 V
PROVIDE DISCONNECT MEANS AND Dir Dir
OVERLOAD PROTECTION AS REQUIRED. Service/Off 1 LINE VOLTAGE POWER SUPPLY. Service/Off
Rev PROVIDE DISCONNECT MEANS AND Rev
2 24 VDC SUPPLY ACCEPTABLE. OVERLOAD PROTECTION AS REQUIRED. 10... 0 V
M23107 10... 2 V
2 24 VDC SUPPLY ACCEPTABLE.
M23097

Wiring for Auxiliary Switches

END SWITCHES (CLASS II-ONLY)

5° 85°

S1 S2 S3 S5 S6

M23110

414 customer.honeywell.com 70-6910


Direct Coupled Damper Actuators—Non-Spring Return
N20 Series: MN6120; MN7220

Controls
Home
Non-Spring Return Direct Coupled Actuator, 175 lb-in
These direct-coupled damper actuators provide adjustable
modulating control for: air dampers, air handling units, ventilation
flaps, louvers, and reliable control for air damper applications with
up to 4.6 m2/50 sq ft (seal-less dampers; air friction-dependent).
• Control for air damper applications with up to 50 sq ft assuming 3.5

Indoor Air Quality


in-lb per sq ft of damper area, velocity independent.
• Patented self-centering shaft adapter.
• Access cover to facilitate connectivity.
• Declutch for manual adjustment.
• Mechanical end limits.
• Field-insatiable auxiliary switches.
• Rotation direction selectable by switch.
• Mountable in any orientation (no IP54 if upside down).
• Mechanical position indicator.

Combustion Controls
• CE approved. UL approved.

Residential
Dimensions in inches (millimeters) Actuator Type: Damper; Valve
Rotational Stroke: 95 ±3 degrees
SHAFT
ADAPTER
Fail Safe Mode: Non-Spring Return

Hydronic Controls
3-15/16 (REVERSED) Torque: 175 lb-in. (20 Nm)
SHAFT (100) 95°
ADAPTER External Auxiliary Switches Available: Yes, SW2-US
Electrical Connections: Enclosed screw terminal strip (22 to 14 AWG)
1-7/8 (48)

Environmental Rating: NEMA2; IP54


Frequency: 50 Hz; 60 Hz
Manual operation: Declutch mechanism
1-3/16
(20.6) 8-25/32
Mounting: Direct Coupled
(223) Maximum Noise Rating, Driving (dBA @ 1m): 40
Rotation to Open: By switch
Rotational Stroke Adjustment: Dual Integral Adj. Stops (3 degree
increments)

Controls
Compatible Damper Shafts: 3/8 to 1.06 in. round or 3/8 to 11/16 in.

Water
3-5/8 (92)
square (10 to 27 mm round or 10 to 18 mm square)
Shaft Adapter Type: Self-centering clamping
MIN 2-3/8 (60)
Materials: Plenum rated plastic housing
Operating Humidity Range (% RH): 5 to 95% RH, non-condensing
Ambient Temperature Range: -5 F to +140 F (-20 C to +60 C)
Storage Temperature Range: -40 F to +175 F (-40 C to +80 C)

Building Automation
Weight: 3.2 lb (1.45 kg)
Includes: Mounting bracket, self-centering shaft adapter
Comments: Integral 1/2 in. NPSM conduit connection.
5-3/16 (132) Approvals:
CE: 89/336/ECC, 73/23/EEC
9-1/16[+/-1/64] (230 [+/-.5])
25/32 (20) ANTI-ROTATION C-Tick: N314
BRACKET
Underwriters Laboratories, Inc. UL873, Plenum Rated
9/32 (7)
Canadian Underwriters Laboratories, Inc. cUL C22.2 No. 24-93
25/128 [+0.002-0.004]
(5) [+0.05-0.10]
5/64 (2) M18923
1/2 (13)

Components
Commercial
Timing
(seconds)
Number
Nominal Power of Internal
Driving @ Consumption Supply Auxiliary
Product Number Control Signal Feedback 60 Hz (Driving) Voltage Input Impedance Switch Switch Ratings
* MN6120A1002 Floating; Two — 95 sec 6 VA, 6 W 24 Vac ±15% — 0 —
position
Pneumatic Controls

* MN6120A1200 Floating; Two — 95 sec 6 VA, 6 W 24 Vac ±15% — 2 250 Vac,


position 5 A res (3 A ind)
* MN7220A2007 (0)2-10 Vdc — 95 sec 6 VA, 6 W 24 Vac ±20% 100K ohm (voltage), 0 —
(4-20 mA w/500 500 ohm (current)
ohm resistor)
* MN7220A2205 (0)2-10 Vdc (0)2-10 Vdc 95 sec 6 VA, 6 W 24 Vac ±20% 100K ohm (voltage), 2 250 Vac,
(4-20 mA w/500 (max. output: 500 ohm (current) 5 A res (3 A ind)
ohm resistor) ±1.0 mA)
Industrial Combustion

* TRADELINE models • SUPER TRADELINE models


Controls

70-6910 415
Direct Coupled Damper Actuators—Non-Spring Return
Used for On/Off Control Wiring for Modulating Control

FLOATING ACTUATOR PROPORTIONAL ACTUATOR


2 -10 Vdc
Direct 0 -10 Vdc
Service/Off
0 -10 Vdc
Reverse
2 -10 Vdc

FEEDBACK
+

2 3 4 CONTROLLER 1 2 3 5
2
1
PROPORTIONAL
CONTROLLER
1 24 VAC
FEEDBACK

24 VAC
+
2

1 POWER SUPPLY. PROVIDE DISCONNECT MEANS -


AND OVERLOAD PROTECTION AS REQUIRED. 1 POWER SUPPLY. PROVIDE DISCONNECT MEANS
2 CONNECTION REQUIRED FOR SPST CONTROL. AND OVERLOAD PROTECTION AS REQUIRED.
M18945A
2 0(2)-10 VDC OF 0(4)-20 mA CONTROL SIGNAL ACCEPTABLE.
Wiring for Floating Control SET CONTROL SIGNAL DIP SWITCH TO "OFF" FOR VOLTAGE.
SET TO "ON" FOR CURRENT.
M18947A

FLOATING ACTUATOR Wiring for Auxiliary Switches


Direct AUXILIARY SWITCHES
Service/Off
Reverse

FLOATING
2 3 4 CONTROLLER COM N.C. N.O. COM N.C. N.O.

S1 S2 S3 S4 S5 S6

1
M18948

24 VAC

1 POWER SUPPLY. PROVIDE DISCONNECT MEANS


AND OVERLOAD PROTECTION AS REQUIRED. M18946A

416 customer.honeywell.com 70-6910


Direct Coupled Damper Actuators—Non-Spring Return
N34 Series: MN6134; MN7234

Controls
Home
Non-Spring Return Direct Coupled Actuator, 300 lb-in
These direct coupled damper actuators provide adjustable
modulating control for air dampers, air handling units, ventilation
flaps, louvers, and reliable control for air damper applications with
up to 7.9 m2/85 sq ft (seal-less dampers; air friction-dependent).

Indoor Air Quality


• Control for air damper applications with up to 85 sq ft assuming 3.5
in-lb per sq ft of damper area, velocity independent.
• Patented self-centering shaft adapter.
• Access cover to facilitate connectivity.
• Declutch for manual adjustment.
• Mechanical end limits.
• Field-installable auxiliary switches.
• Rotation direction selectable by switch.
• Mountable in any orientation (no IP54 if upside down).

Combustion Controls
• Mechanical position indicator.
• CE approved. UL approved.

Residential
Dimensions in inches (millimeters)

SHAFT Actuator Type: Damper; Valve


ADAPTER
Rotational Stroke: 95 ±3 degrees

Hydronic Controls
3-15/16 (REVERSED)
SHAFT
ADAPTER
(100) 95° Fail Safe Mode: Non-Spring Return
Torque: 300 lb-in. (34 Nm)
1-7/8 (48)

External Auxiliary Switches Available: Yes, SW2-US


Electrical Connections: Enclosed screw terminal strip (22 to 14 AWG)
Environmental Rating: NEMA2
1-3/16
(20.6)
Frequency: 50 Hz; 60 Hz
8-25/32
(223) Manual operation: Declutch mechanism
Mounting: Direct Coupled
Maximum Noise Rating, Driving (dBA @ 1m): 40
Rotation to Open: By switch
Compatible Damper Shafts: 3/8 to 1.06 in. round or 3/8 to 11/16 in.

Controls
Water
3-5/8 (92)
square (10 to 27 mm round or 10 to 18 mm square)
Shaft Adapter Type: Self-centering clamping
MIN 2-3/8 (60) Materials: Plenum rated plastic housing
Operating Humidity Range (% RH): 5 to 95% RH, non-condensing
Ambient Temperature Range: -5 F to +140 F (-20 C to +60 C)
Storage Temperature Range: -40 F to +175 F (-40 C to +80 C)
Weight: 3.2 lb (1.45 kg)

Building Automation
Includes: Mounting bracket, self-centering shaft adapter
Comments: Integral 1/2 in. NPSM conduit connection.
5-3/16 (132) Approvals:
CE: 89/336/ECC, 73/23/EEC
9-1/16[+/-1/64] (230 [+/-.5])
ANTI-ROTATION
C-Tick: N314
25/32 (20)
BRACKET Underwriters Laboratories, Inc. UL873, Plenum Rated
9/32 (7) Canadian Underwriters Laboratories, Inc. cUL C22.2 No. 24-93
25/128 [+0.002-0.004]
(5) [+0.05-0.10]
5/64 (2) M18923
1/2 (13)

Components
Commercial
Timing
(seconds) Number of
Power Internal
Nominal Consumption Supply Auxiliary
Product Number Control Signal Feedback Driving @ 60 Hz (Driving) Voltage Input Impedance Switch
* MN6134A1003 Floating; Two position — 95 sec 9 VA, 9 W 24 Vac ±15%, — 0
24 Vdc
Pneumatic Controls

* MN7234A2008 (0)2-10 Vdc (4-20 mA (0)2-10 Vdc (max. 95 sec 8 VA, 6 W 24 Vac ±20%, 100K ohm (voltage), 0
w/500 ohm resistor) output: ±1.0 mA) 24 Vdc 500 ohm (current)
* TRADELINE models • SUPER TRADELINE models
Industrial Combustion
Controls

70-6910 417
Direct Coupled Damper Actuators—Non-Spring Return
Used for On/Off Control Wiring for Modulating Control

FLOATING ACTUATOR PROPORTIONAL ACTUATOR


2 -10 Vdc
Direct 0 -10 Vdc
Service/Off
Reverse 0 -10 Vdc

2 -10 Vdc

FEEDBACK
+

CONTROLLER
2 3 4 1 2 3 5
2
1
PROPORTIONAL
CONTROLLER
1 24 VAC
FEEDBACK

24 VAC
+
2

1 POWER SUPPLY. PROVIDE DISCONNECT MEANS


-
AND OVERLOAD PROTECTION AS REQUIRED. 1 POWER SUPPLY. PROVIDE DISCONNECT MEANS
2 CONNECTION REQUIRED FOR SPST CONTROL. AND OVERLOAD PROTECTION AS REQUIRED.
M18945A
2 0(2)-10 VDC OF 0(4)-20 mA CONTROL SIGNAL ACCEPTABLE.
Wiring for Floating Control SET CONTROL SIGNAL DIP SWITCH TO "OFF" FOR VOLTAGE.
SET TO "ON" FOR CURRENT.
M18947A
FLOATING ACTUATOR
Wiring for Auxiliary Switches
Direct
Service/Off
AUXILIARY SWITCHES
Reverse

FLOATING
2 3 4 CONTROLLER
COM N.C. N.O. COM N.C. N.O.

S1 S2 S3 S4 S5 S6
1
M18948
24 VAC

1 POWER SUPPLY. PROVIDE DISCONNECT MEANS


AND OVERLOAD PROTECTION AS REQUIRED. M18946A

418 customer.honeywell.com 70-6910


Direct Coupled Damper Actuators—Fire and Smoke
ML4115; ML8115

Controls
Home
Fire and Smoke, Fast-Acting, Two-Position Actuators, 30 lb-in
Spring return direct coupled actuators (DCA) for on/off damper
control with an integral junction box. The actuator accepts an on/
off signal from a single-pole, single-throw (SPST) controller. They
are designed to operate reliably in smoke control systems
requiring Underwriter's Laboratories Inc. UL555S ratings up to

Indoor Air Quality


350 F.
• Integral spring return.
• No audible noise during holding.
• Electronic circuitry provides efficient operation while eliminating the
need for limit switches.
• Ninety-five degree angle of rotation for tight damper closure.
• Die-cast aluminum housing.
• Housing design allows flush mounting to damper.
• Integral junction box with three conduit openings eliminates need for

Combustion Controls
separate wiring box.
• Mounts to 3/8 or 1/2 in. round or square shaft.

Residential
Dimensions in millimeters (inches)
Actuator Type: Damper
2 (51) Rotational Stroke: 95 ±3 degrees

Hydronic Controls
1 (25) Fail Safe Mode: Spring Return
Torque: 30 lb-in. (3.4 Nm)
5/8
Minimum Driving Torque at 350 F: 30 lb-in.
(17) Spring Return Torque: 30 lb-in. (3.4 Nm)
1
External Auxiliary Switches Available: Yes, 32003532-005
Number of Internal Auxiliary Switches: 0
6 3/8 Electrical Connections: Two color-coded leads
(161)
Electrical Connection Length: 16 in. (406 mm)
Environmental Rating: NEMA1
Frequency: 60 Hz
Mounting: Direct Coupled

Controls
Water
Maximum Noise Rating, Holding (dBA @ 1m): 20 (no audible noise)
Maximum Noise Rating, Driving (dBA @ 1m): 65
7 1/2
(192) Compatible Damper Shafts: 3/8 to 1/2 in. square or round
(10 to 13 mm square/round)
Shaft Adapter Type: Aluminum Hub, two set screws
Materials: Aluminum housing
Operating Humidity Range (% RH): 5 to 95% RH, non-condensing

Building Automation
Ambient Temperature Range: 0 F to +130 F (-18 C to +55 C)
Storage Temperature Range: -40 F to 140 F (-40 C to +60 C)
2 (51) 3 5/16 (84) Weight: 6 lb (2.72 kg)
4 (102) 1/16 (2) Comments: Integral junction box with three 7/8 in. conduit openings
(fittings not included)
7/8 (22)
Approvals:
Underwriters Laboratories, Inc. UL873, Plenum Rated
Canadian Underwriters Laboratories, Inc. cUL C22.2 No. 24-93
1 ML4115/ML8115 HAVE SMALLER
HUB WITH TWO SET SCREWS.

Components
Commercial
ML4105/ML8105 HAVE LONGER
HUB WITH FOUR SET SCREWS.

5 1/8 (129) M13053A

Timing (seconds) Power Consumption


Spring Maximum Nominal Maximum
Pneumatic Controls

Return Driving @ Driving @ Spring


Product Number Control Signal Direction 60 Hz 60 Hz Return (Driving) (Holding) Supply Voltage Includes
ML4115A1009 Two position; SPST CCW 25 sec 18 sec 15 sec 0.18A, 18W 0.11A, 9W 120 Vac ±10% Ground Screw
ML4115B1008 Two position; SPST CW 25 sec 18 sec 15 sec 0.18A, 18W 0.11A, 9W 120 Vac ±10% Ground Screw
ML8115A1005 Two position; SPST CCW 25 sec 18 sec 15 sec 16 VA 8 VA 24 Vac ±20% —
ML8115B1004 Two position; SPST CW 25 sec 18 sec 15 sec 16 VA 8 VA 24 Vac ±20% —
Industrial Combustion
Controls

70-6910 419
Direct Coupled Damper Actuators—Fire and Smoke
Typical 24 Vac wiring Typical 230 Vac Wiring

L1 ( )
L1 ( )
RED BROWN
24 VAC BLACK 230 VAC BLUE

L2 ( ) L2 ( )

M17585A M17588A

Typical 120 Vac wiring

L1 ( )
BLACK
120 VAC WHITE
L2 ( )

M17589A

420 customer.honeywell.com 70-6910


Direct Coupled Damper Actuators—Fire and Smoke
MS4209F; MS4309F; MS4709F; MS4809F; MS8209F; MS8309F

Controls
Home
Fast-Acting, Two-Position Actuators, 80 lb-in
Spring return direct coupled actuators (DCA) for on/off damper
control with an integral junction box. The actuator accepts an on/
off signal from a single-pole, single-throw (SPST) controller. They
are designed to operate reliably in smoke control systems
requiring Underwriter's Laboratories Inc. UL555S ratings up to

Indoor Air Quality


350 F.
• Integral spring return ensures level of return torque.
• Fifteen-second spring return timing.
• No special cycling required during long-term holding.
• No audible noise during holding.
• Patent pending design eliminates need for limit switches to reduce
power consumption.
• Models available for 24, 120, and 230 Vac.
• Ninety-five degree angle of rotation for tight damper closure.

Combustion Controls
• Actuator holds rated torque at reduced power level.
• Die-cast aluminum housing. Housing design allows flush mounting

Residential
to damper.
• Integral junction box with three conduit openings eliminates need for
separate wiring box.

Dimensions in millimeters (inches)


Actuator Type: Damper
2 (51) Rotational Stroke: 95 ±3 degrees

Hydronic Controls
1 (25) Fail Safe Mode: Spring Return
Torque: 80 lb-in. (9 Nm)
5/8
Minimum Driving Torque at 350 F: 80 lb-in.
(17) Spring Return Torque: 80 lb-in. (9 Nm)
External Auxiliary Switches Available: Yes, 32003532-005
Number of Internal Auxiliary Switches: 0
6 3/8 Environmental Rating: NEMA1
(161)
Frequency: 60 Hz
Mounting: Direct Coupled
Maximum Noise Rating, Holding (dBA @ 1m): 20 (no audible noise)
Maximum Noise Rating, Driving (dBA @ 1m): 80

Controls
Compatible Damper Shafts: 3/8 to 1/2 in. square or round (10 to 13

Water
mm square/round)
7 1/2
(192) Shaft Adapter Type: Aluminum Hub, four set screws
Supply Voltage: 120 Vac +10%, -15%
Materials: Aluminum housing
Operating Humidity Range (% RH): 5 to 95% RH, non-condensing
Ambient Temperature Range: 0 F to +130 F (-18 C to +55 C)

Building Automation
Storage Temperature Range: -40 F to 140 F (-40 C to +60 C)
Weight: 6 lb (2.72 kg)
2 (51) 3 5/16 (84) Comments: Integral junction box with three 7/8 in. conduit openings
4 (102) 1/16 (2) (fittings not included)
Approvals:
7/8 (22) CE: 89/336/ECC, 73/23/EEC
C-Tick: N314
Underwriters Laboratories, Inc. UL873, Plenum Rated
Canadian Underwriters Laboratories, Inc. cUL C22.2 No. 24-93

Components
Commercial
5 1/8 (129) M17508

Pneumatic Controls
Industrial Combustion
Controls

70-6910 421
Direct Coupled Damper Actuators—Fire and Smoke
Electrical
Connection
Timing (seconds) Power Consumption Length
Spring Maximum Nominal Maximum
Control Return Driving @ Driving Spring Supply Electrical
Product Number Signal Direction 60 Hz @ 60 Hz Return (Driving) (Holding) Voltage Connections (inch) (m)
MS4209F1007 Two position; CW 25 sec 15 sec 15 sec 0.25A, 23W 0.13A, 7W 120 Vac Two color- 16 in. 406
SPST +10%, -15% coded leads mm
MS4309F1005 Two position; CCW 25 sec 15 sec 15 sec 0.25A, 23W 0.13A, 7W 120 Vac Two color- 16 in. 406
SPST +10%, -15% coded leads mm
MS4709F1014 Two position; CW 25 sec 15 sec 15 sec 0.13A, 23W 0.09A, 7W 230 Vac ±10% Appliance 39 in. 1m
SPST cable
MS4809F1012 Two position; CCW 25 sec 15 sec 15 sec 0.13A, 23W 0.09A, 7W 230 Vac ±10% Appliance 39 in. 1m
SPST cable
MS8209F1003 Two position; CW 25 sec 15 sec 15 sec 23 VA 7 VA 24 Vac +20%, Two color- 16 in. 406
SPST -10% coded leads mm
MS8309F1001 Two position; CCW 25 sec 15 sec 15 sec 23 VA 7 VA 24 Vac +20%, Two color- 16 in. 406
SPST -10% coded leads mm
Typical 24 Vac wiring Typical 230 Vac Wiring

L1 ( )
L1 ( )
RED BROWN
24 VAC BLACK 230 VAC BLUE

L2 ( ) L2 ( )

M17585A M17588A

Typical 120 Vac wiring

L1 ( )
BLACK
120 VAC WHITE
L2 ( )

M17589A

422 customer.honeywell.com 70-6910


Direct Coupled Damper Actuators—Fire and Smoke
MS4120F; MS4620F; MS8120F

Controls
Home
Fast-Acting, Two-Position Actuators, 175 lb-in
Spring return direct coupled actuators (DCA) for on/off damper
control with an integral junction box. The actuator accepts an on/
off signal from a single-pole, single-throw (SPST) controller. They
are designed to operate reliably in smoke control systems
requiring Underwriter's Laboratories Inc. UL555S ratings up to

Indoor Air Quality


350 F.
• Brush DC submotor with electronic stall protection for 2-position
models
• Self-centering shaft adapter (shaft coupling) for wide range of shaft
sizes
• Models available for use with two-position, single pole single throw
(spst), line- (Series 40) or low- (Series 80) voltage controls
• Metal housing with built-in mechanical end limits
• Spring return direction field-selectable

Combustion Controls
• Shaft position indicator and scale
• Manual winding capability with locking function

Residential
• UL (cUL) listed and CE compliant
• All Models are plenum-rated per UL873

Hydronic Controls
Dimensions in millimeters (inches)
Actuator Type: Damper
3-15/16 (100) Rotational Stroke: 95 ±3 degrees
2 (50) Fail Safe Mode: Spring Return
Torque: 175 lb-in. (20 Nm)

Controls
Minimum Driving Torque at 350 F: 175 lb-in.

Water
1-9/16 Spring Return Torque: 175 lb-in. (20 Nm)
(40) Spring Return Direction: By orientation
External Auxiliary Switches Available: No
Electrical Connections: Teflon-jacketed cable
Electrical Connection Length: 40 in. (1 m)
Environmental Rating: NEMA2
Ingress Protection Rating: IP54

Building Automation
Frequency: 60 Hz
Manual operation: Manual crank
Mounting: Direct Coupled
10-11/16
(271)
Maximum Noise Rating, Holding (dBA @ 1m): 20 (no audible noise)
Maximum Noise Rating, Driving (dBA @ 1m): 70
Compatible Damper Shafts: 3/8 to 1.06 in. round or 3/8 to 11/16 in.
8-5/8 square (10 to 27 mm round or 10 to 18 mm square)
(220) Shaft Adapter Type: Self-centering clamping
Supply Voltage: 120 Vac ±10%
Materials: Aluminum housing

Components
Commercial
Operating Humidity Range (% RH): 5 to 95% RH, non-condensing
Ambient Temperature Range: -40 F to +130 F (-40 C to +55 C)
Storage Temperature Range: -40 F to +140 F (-40 C to +60 C)
Weight: 8 lb (3.63 kg)
Includes: Self-centering shaft adapter, 3mm crank
Comments: Two integral 3/8 in. flexible conduit connections
Approvals:
CE: 89/336/ECC, 73/23/EEC
Pneumatic Controls

C-Tick: N314
Underwriters Laboratories, Inc. UL873, Plenum Rated
M20051 1/4 (6) 2-15/16 (75)
Canadian Underwriters Laboratories, Inc. cUL C22.2 No. 24-93
Industrial Combustion
Controls

70-6910 423
Direct Coupled Damper Actuators—Fire and Smoke
Timing (seconds) Power Consumption Number
of
Nominal Maximum Internal
Driving Spring Auxiliary
Product Number Control Signal @ 60 Hz Return (Driving) (Holding) Supply Voltage Switch Switch Ratings
MS4120F1006 Two position: SPST 15 sec 15 sec 0.35A, 35W 0.15A, 10W 120 Vac ±10% 0 —
MS4120F1204 Two position: SPST 15 sec 15 sec 0.35A, 35W 0.15A, 10W 120 Vac ±10% 2 250 Vac, 5 A res (3 A ind)
MS4620F1005 Two position: SPST 15 sec 15 sec 0.20A, 35W 0.14A, 10W 230 Vac ±10% 0 —
MS4620F1203 Two position: SPST 15 sec 15 sec 0.20A, 35W 0.14A, 10W 230 Vac ±10% 2 250 Vac, 5 A res (3 A ind)
MS8120F1002 Two position: SPST 15 sec 15 sec 45 VA 10 VA 24 Vac +20%, -10% 0 —
MS8120F1200 Two position: SPST 15 sec 15 sec 45 VA 10 VA 24 Vac +20%, -10% 2 250 Vac, 5 A res (3 A ind)
Wiring for 24V Control Wiring for 120V Control

MS8120F MS4120F

L2 ( )
BLACK L2 ( ) WHITE
24 VAC RED 120 VAC
BLACK
L1 ( ) L1 ( )
GREEN

GREEN
BLUE BLUE
7° AUXILIARY 7° AUXILIARY
BLUE SWITCH BLUE
SWITCH
YELLOW YELLOW
85° AUXILIARY 85° AUXILIARY YELLOW
YELLOW
SWITCH SWITCH

M20053A M20056A

424 customer.honeywell.com 70-6910


Direct Coupled Damper Actuators—Accessories
Q7002 Interface Modules

Controls
Home
The Q7002 Interface Modules allow controllers with an otherwise
incompatible signal to control an Economizer Logic Module or
Direct Coupled Actuator.
• 24 Vac or 24 Vdc power.
• Available for input signals: dc voltage, current, or resistive; and
pulse-width modulation (PWM).
• Available to provide output: analog voltage or current for an actuator.

Indoor Air Quality


• Inputs and outputs are jumper-selectable and include adjustable
zero and span.
• Output is jumper-selectable direct or reverse acting.
• Includes reference voltage and current to power an input device or
sensor.
• PWM time base is user-selectable with positive or negative input
reference; all ranges have 255-step resolution.
• Multiplex mode enables one PWM signal from a Building Automation
System (BAS) controller to address and control up to eight interface

Combustion Controls
modules.

Residential
Dimensions in inches (millimeters)
Frequency: 60 Hz
Mounting: Enclosure (NEMA 1) with mounting tabs
Used With: Direct-Coupled Proportional Actuators and Modutrol Motors
4-9/16
(116)

3-3/8

Hydronic Controls
(86)

2-3/4 (70) 3/8


(10)
4-7/8 (124) 2 (51)

ENCLOSURE MODELS M18985

Supply

Controls
Water
Product Number Output Burden Voltage Description Comments
Q7002B1009 0 to 10 Vdc > 500 Ohm; 24 Vac ±20%, Transducer, Accepts dc voltage, current, or resistive Input: dc voltage, current, or resistive,
0 to 20 mA < 500 ohm 24 Vdc input and provides a voltage or current output Output: voltage or current output
Q7002C1007 0 to 10 Vdc > 500 Ohm; 24 Vac ±20%, Transducer, Accepts a pulse-width modulation Input: PWM signal,
0 to 20 mA < 500 ohm 24 Vdc (PWM) signal and provides a voltage output Output: analog voltage

Building Automation
Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 425
Direct Coupled Damper Actuators—Accessories
Accessories for Direct Coupled Damper Actuators
Compatibility Chart SPRING RETURN
NON-SPRING
RETURN

ML41x5, ML81x5

MLxx61, MLxx74
ACTUATOR ACCESSORIES

MNxx20A
MNxx34A
MSxx10A
MSxx20A

MSxx09F
MSxx20F

MNXX05
MNxx10
MSxx03
MSxx05
Control, Positioning, Feedback
200976A Feedback Potentiometer (500 ohm) •
200976C Feedback Potentiometer (2000 ohm) •
201052A Auxiliary Switch (1 SPDT) •
201052B Auxiliary Switch (2 SPDT) •
205860 Minimum Position Potentiometer • • • • • • • • •
32003532-005 High Temperature Auxiliary Switch (2 SPDT) • •
32006306-001 Resistor Kit (500 ohm); converts 4-20 mA signal to 2-10 Vdc • • • • • • • • •
SSW2-1M Auxiliary Switch Package - Low Torque Non Spring Return • •
SW2-US Auxiliary Switch Package (2 adjustable SPDT switches) • • • •
Q7002 Interface Modules
Q7002B1009 Transducer, Accepts dc voltage, current, or resistive input • • • • • • •
Q7002C1007 Transducer, Accepts a pulse-width modulation (PWM) • • • • • • • • •
Mounting
205649 Mounting Bracket • • • • •
32007205-001 Actuator Mounting Plate • • • • • • • • • •
32007205-002 Damper Blade Drive Lever (<24 in.) • • • • • • • • • • • •
32007205-003 Damper Blade Drive Lever (>24 in.) • • • • • • • • • • • •
32007205-004 Damper External Drive Pin Clip • • • • • • • • • • • •
32007205-005 Damper External Drive Pin Kit • • • • • • • • • • • •
32007205-006 Damper Axle Coupling • • • • • • • • • • • •
32007205-007 Damper Crossover Jumper Bracket • • • • • • • • • • • •
50000407-001 Tandem Mounting Kit • • • • • • • • •
50001194-001 Foot Mounting Kit • • • • • • •
50006427-001 Flexible Anti-rotation Bracket • • • • •
STRN-BRKT Anti-rotation Bracket • •
STRN-CRK-01 Crank Arm Kit • •
STRN-ECONO-01 Economizer Retrofit Kit • •
STRN-WMK-01 Wall Mount Kit • •
Rotation Limiters, Position Indicators
4074ENJ Stroke Stop/Minimum Position Kit •
Ball Joints, Push Rods
27518 Ball Joint (5/16 in.) • • • • • • • • • • • •
27520A Push Rod (5/16 in. dia., 5 in. length) • • • • • • • • • • • •
27520B Push Rod (5/16 in. dia., 10 in. length) • • • • • • • • • • • •
27520C Push Rod (5/16 in. dia., 12 in. length) • • • • • • • • • • • •
27520D Push Rod (5/16 in. dia., 15 in. length) • • • • • • • • • • • •
27520E Push Rod (5/16 in. dia., 18 in. length) • • • • • • • • • • • •
27520G Push Rod (5/16 in. dia., 24 in. length) • • • • • • • • • • • •
27520H Push Rod (5/16 in. dia., 28 in. length) • • • • • • • • • • • •

426 customer.honeywell.com 70-6910


Direct Coupled Damper Actuators—Accessories
Compatibility Chart

Controls
NON-SPRING

Home
SPRING RETURN RETURN

ML41x5, ML81x5

MLxx61, MLxx74
ACTUATOR ACCESSORIES

MNxx20A
MNxx34A
MSxx10A
MSxx20A

MSxx09F
MSxx20F

MNXX05
MNxx10
MSxx03
MSxx05

Indoor Air Quality


27520K Push Rod (5/16 in. dia., 36 in. length) • • • • • • • • • • • •
27520L Push Rod (5/16 in. dia., 48 in. length) • • • • • • • • • • • •
27520Q Push Rod (5/16 in. dia., 8 in. length) • • • • • • • • • • • •
Crankarms

Combustion Controls
26026G Damper Crank Arm, 1/2 in. damper shaft • • • • • • • • • • • •

Residential
205830A Rotary-to-Linear Kit •
STRN-CA-01 Non-Self-centering Crank Arm • •
STRN-CA-02 Self-centering Crank Arm • •
Shaft Adapters
32003167-001 Shaft Adapter (3/8 in.) •

Hydronic Controls
32003168-001 Short Shaft Adapter (3/4-1/2 in.) • • • • • • • • • • • •
32003168-002 Short Shaft Adapter (5/8-1/2 in.) • • • • • • • • • • • •
32003168-003 Short Shaft Adapter (9/16-1/2 in.) • • • • • • • • • • • •
32004254-001 Self Centering Shaft Adapter •
32004254-002 Self Centering Shaft Adapter • •
32004254-003 Self Centering Shaft Adapter •
4074EVK Short Shaft Kit •

Controls
Water
4074ENY Stroke Stop Kit •
STRN-SCSA Self-centering Shaft Adapter • •
Enclosures
32003036-001 Weather Enclosure • • • • • • • • • •
50005859-001 NEMA 4 Enclosure • • • • • • •

Building Automation
7640QW Metal Enclosure •
Miscellaneous
32000085-001 Strain Relief Fitting (10 pack) • • • • • •
STRN-STRNRLF Strain Relief Fitting (10 pack) • •

Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 427
Direct Coupled Damper Actuators—Accessories
Control, Positioning, Feedback Accessories
Product Number Description Used With
200976A Auxiliary Feedback Potentiometer (0 to 500 ohm) ML6161, ML6174, ML7161, ML7174
Used With: ML6161, ML6174, ML7161, ML7174
200976C Auxiliary Feedback Potentiometer (0 to 2000 ML6161, ML6174, ML7161, ML7174
ohm) Used With: ML6161, ML6174, ML7161,
ML7174

201052A Auxiliary Switch Package, Single Used With: ML6161, ML6174, ML7161, ML7174
ML6161, ML6174, ML7161, ML7174
201052B Auxiliary Switch Package, Double Used With: ML6161, ML6174, ML7161, ML7174
ML6161, ML6174, ML7161, ML7174
201052C Auxiliary Switch Package, Triple Used With: ML6161, ML6174, ML7161, ML7174
ML6161, ML6174, ML7161, ML7174
201052D Auxiliary Switch Package, Double Used With: ML6161, ML6174, ML7161, ML7174
ML6161, ML6174, ML7161, ML7174
205860 Electronic Remote Minimum Position Proportional Actuators
Potentiometer Used With: Proportional Actuators

32003532-003 High Temperature Dual Switch Assembly ML4105, ML8105, ML4115, ML8115,
ML4125, ML8125, ML4135, ML8135,
MS4209, MS4309, MS4709, MS4809,
MS8209, MS8309

32003532-004 High Temperature Dual Switch Assembly ML4105, ML8105, ML4115, ML8115,
ML4125, ML8125, ML4135, ML8135,
MS4209, MS4309, MS4709, MS4809,
MS8209, MS8309

M22537

32003532-005 High Temperature Dual Switch Assembly ML4105, ML8105, ML4115, ML8115,
ML4125, ML8125, ML4135, ML8135,
MS4209, MS4309, MS4709, MS4809,
MS8209, MS8309;

32006306-001 Resistor Kit (500 ohm, converts 4-20mA to 2- Proportional Actuators


10Vdc)

428 customer.honeywell.com 70-6910


Direct Coupled Damper Actuators—Accessories

Controls
Product Number Description Used With

Home
SSW2-1M Auxiliary Switch Package - Low Torque Non MN Series Actuator (44 in-lb, 88 in-lb)
Spring Return

Indoor Air Quality


SW2-US Auxiliary Switch Package (2 adjustable SPDT MS and MN Series High Torque
switches) Actuators (MNXX20 and XX34)

Combustion Controls
Residential
Mounting Accessories

Hydronic Controls
Product Number Description Used With
205649 Mounting Bracket Used With: 150 and 300 150 and 300 lb-in. NSR and SR
lb-in NSR and SR Actuators (except 25, 53 and 142 lb-in)
Actuators

205820A 3-Point Mounting Kit Used With: 150 lb-in 150 lb-in.NSR and 25 and
NSR and 25 and 53 lb-in Actuators (ML 53 lb-in.Actuators (ML Series)
Series)

Controls
Water
Building Automation
205820 M11561

32007205-001 Direct Coupled Actuator Mounting Bracket Damper with External Actuator
Used With: Damper with External Actuator Mounting (i.e., 32007205-005 Kit)
Mounting (i.e., 32007205-005 Kit)

Components
Commercial
32007205-002 Damper Blade Drive Lever (Small) Used All Actuators and Dampers
With: All Actuators and Dampers
Pneumatic Controls

M13690
Industrial Combustion
Controls

70-6910 429
Direct Coupled Damper Actuators—Accessories
Product Number Description Used With
32007205-003 Damper Blade Drive Lever (Large) Used All Actuators and Dampers
With: All Actuators and Dampers

M13691

32007205-004 Retaining Clip, Damper External Drive Pin Damper with External Actuator
Used With: Damper with External Actuator Mounting (i.e., 32007205-005 Kit)
Mounting (i.e., 32007205-005 Kit)

32007205-005 Damper External Drive Pin Kit Used With: Damper with External Actuator
Damper with External Actuator Mounting Mounting (i.e., 32007205-005 Kit)
(i.e., 32007205-005 Kit)

32007205-006 Damper Axle Coupling Used With: Multi- Multi-Section Dampers


Section Dampers

32007205-007 Jumper Bracket Used With: Multi-Section Multi-Section Dampers


Dampers

50000407-001 Actuator Tandem Mounting Kit N20 Actuators; N34 Actuators;


S05 Actuators; S10 Actuators;
S20 Actuators

50001194-001 Foot Mounting Kit MS and MN Series High Torque


Actuators (MNXX20 and XX34)

430 customer.honeywell.com 70-6910


Direct Coupled Damper Actuators—Accessories

Controls
Product Number Description Used With

Home
50006427-001 Flexible Anti-Rotation Bracket N20 Actuators; N34 Actuators;
S05 Actuators; S10 Actuators;
S20 Actuators

STRN-BRKT Anti-rotation Bracket for S03 and S05 Series S03 Actuators; S05 Actuators
Actuators

Indoor Air Quality


M29089

STRN-CRK-01 Crank arm kit for S03 and S05 Series S03 Actuators; S05 Actuators
Actuators

Combustion Controls
Residential
Hydronic Controls
M29085

STRN-ECONO-01 Economizer Retrofit Kit for S03 and S05 S03 Actuators; S05 Actuators
Series Actuators
CLINCH NUTS
PRE ATTACHED
TO BACK OF
BRACKET

Controls
Water
M29084

STRN-WMK-01 Wall mount kit for S03 and S05 Series S03 Actuators; S05 Actuators
Actuators

Building Automation
CLINCH NUTS
PRE ATTACHED
TO BACK OF
BRACKET

M29082

Components
Rotational Limiters, Position Indicators

Commercial
Product Number Description Used With
4074ENG Stop Pin Used With: ML6161, ML6174, ML6161, ML6174, ML7161, ML7174
ML7161, ML7174 Pneumatic Controls

4074ENJ Minimum Position Kit Used With: ML6161, ML6161, ML6174, ML7161, ML7174
ML6174, ML7161, ML7174
Industrial Combustion
Controls

70-6910 431
Direct Coupled Damper Actuators—Accessories
Ball Joints, Push Rod Accessories
Product Number Description Used With
27518 Crankarm balljoint with 1/4 - 28 UNF male threads, fits 5-16 inch All Actuators and Dampers
diameter push rods

27520A Push Rod (5/16 in. dia., 5 in. length) Used With: All Actuators and All Actuators and Dampers
Dampers
27520B Push Rod (5/16 in. dia., 10 in. length) Used With: All Actuators and All Actuators and Dampers
Dampers
27520C Push Rod (5/16 in. dia., 12 in. length) All Actuators and Dampers
27520D Push Rod (5/16 in. dia., 15 in. length) Used With: All Actuators and All Actuators and Dampers
Dampers
27520E Push Rod (5/16 in. dia., 18 in. length) Used With: All Actuators and All Actuators and Dampers
Dampers
27520G Push Rod (5/16 in. dia., 24 in. length) All Actuators and Dampers
27520H Push Rod (5/16 in. dia., 28 in. length) Used With: All Actuators and All Actuators and Dampers
Dampers
27520J Push Rod (5/16 in. dia., 32 in. length) Used With: All Actuators and All Actuators and Dampers
Dampers
27520K Push Rod (5/16 in. dia., 36 in. length) All Actuators and Dampers
27520L Push Rod (5/16 in. dia., 48 in. length) All Actuators and Dampers
27520Q Push Rod (5/16 in. dia., 8 in. length) Used With: All Actuators and All Actuators and Dampers
Dampers

Crankarms
Product Number Description Used With
205830A Rotary-to-Linear Kit Used With: 35 and 70 lb-in NSR 35 and 70 lb-in.NSR
Actuators

26026G Damper Crank Arm, 1/2 in. damper shaft All Actuators and Damper

STRN-CA-01 Non Self-centering Crank Arm for S03 and S05 Series S03 Actuators; S05 Actuators
Actuators

M29087

STRN-CA-02 Self-centering Crank Arm for S03 and S05 Series S03 Actuators; S05 Actuators
Actuators

M29086

432 customer.honeywell.com 70-6910


Direct Coupled Damper Actuators—Accessories
Shaft Adaptor Accessories

Controls
Home
Product Number Description Used With
32003167-001 3/8 in. Shaft Adapter Used With: ML6161, ML6161; ML6174; ML7161; ML7174; ML7999
ML6174, ML7161, ML7174, ML7999

Indoor Air Quality


32003168-001 Short Shaft Adapter (3/4 in. to 1/2 in. ) Used All Actuators and Dampers
With: All Actuators and Dampers
32003168-002 Short Shaft Adapter (5/8 in. to 1/2 in. ) Used All Actuators and Dampers
With: All Actuators and Dampers
32003168-003 Short Shaft Adapter (9/16 in. to 1/2 in. ) Used All Actuators and Dampers

Combustion Controls
With: All Actuators and Dampers

Residential
Hydronic Controls
32004254-001 Self-Centering Shaft Adapter Used With N20 N20 Actuators
Actuators
32004254-002 Self-Centering Shaft Adapter Used With S10, S10 Actuators; S20 Actuators
S20 Actuators
32004254-003 Self-Centering Shaft Adapter Used With: N34 N34 Actuators
Actuators

Controls
Water
4074ENY 3/8 in. Shaft Kit Used With: ML6161, ML6174, ML6161, ML6174, ML7161, ML7174
ML7161, ML7174

Building Automation
4074EVK Short Shaft Kit Used With: ML6161, ML6174, ML6161, ML6174, ML7161, ML7174
ML7161, ML7174

Components
Commercial
STRN-SCSA Self-centering Shaft Adapter for S03 and S05 S03 Actuators; S05 Actuators
Series Actuators Pneumatic Controls

M29088
Industrial Combustion
Controls

70-6910 433
Direct Coupled Damper Actuators—Accessories
Enclosure Accessories
Product Number Description Used With
32003036-001 Weather Enclosure Used With: All Actuators All Actuators

32004783-001 Weather Enclosure Used With: Small Actuators & All Actuators
Economizer Logic Modules
50005859-001 NEMA 4 Enclosure for Direct Coupled Actuator 150 lb-in. NSR Actuators (ML
Series); ML6161, ML6174,
ML7161, ML7174; N20 Actuators;
N34 Actuators; S03 Actuators; S05
Actuators; S10 Actuators; S20
Actuators

7640QW Enclosure for Conduit Connection Used With: ML6161, ML6161, ML6174, ML7161,
ML6174, ML7161, ML7174 ML7174

Miscellaneous Accessories
Product Number Description Used With
32000085-001 Strain Relief Fitting (10 pack) MS and MN Series Actuators

32003967-003 Power Control Module; for W7763/T6984 W/ML6144 and —


MIT System
STRN-STRNRLF Strain Relief Fitting for S03 and S05 Series Actuators S03 Actuators; S05 Actuators

434 customer.honeywell.com 70-6910


Economizer Systems
Economizer Systems Quick Selection Guide

Controls
Home
ECOMOMIZER SYSTEM SELECTION

INCLUDE

Indoor Air Quality


NO Demand Control Ventilation
(Standard) (DCV)?

YES
(Advanced) M13300

Motor Type Motor Logic Module Sensors Motor Type Motor Logic Module Sensors
Foot Mount M7415 W7459A,D Enthalpy: C7400 a Foot Mount M7415 W7460 Enthalpy: C7400a with
25 lb-in. Torque M9175 with C7150/C7046 25 lb-in. Torque M7215 W7212/13/14 C7150/C7046
H705 or W7210b

Combustion Controls
M9175 W7215b,W7212b,
Temperature: C7660c W7213/14 Temperature: C7660c

Residential
DCA MS7505 W7210 with C7150/C7046 DCA MS7505 W7215 with C7150/C7046
44 lb-in. Torque 44 lb-in. Torque
Foot Mount M7285 W7210 Foot Mount M7285 W7215, W7212, CO2: C7232 or C7632
60 lb-in. Torque M7286 60 lb-in. Torque M7286 W7213/14
M9185 H705, W7210b M9185 W7215, W7212b,
M9186 M9186
W7213/14b
DCA MS7510 W7210 DCA MS7510 W7215, W7212,

Hydronic Controls
88 lb-in. Torque 88 lb-in. Torque W7213/14
DCA MS7520 W7210 DCA MS7520 W7215, W7212,
175 lb-in. Torque 175 lb-in. Torque W7213/14
a
Enthalpy sensor. Use two for differential enthalpy and one for single enthalpy.
For Dry Bulb only, use C7660 for single dry bulb only. C7660 cannot be used for differential dry bulb.
b To operate a Series 90 motor, the W7210 and W7215 require a Q7230 interface module or the proper resistor combination
(included in the 4074EJM resistor kit), see form 63-2544 for details.
c
C7660 can only be used in a single (referential) temperature operation. C7660 cannot be used for differential dry bulb.
NOTE: Series 90 Mod Motors™ can be retrofit using W7210, W7212 or W7215 Economizer Logic Modules and a Q7230 or the proper resistor combination.
Refer to form 63-2544 for details on using Economizer Logic Modules with Series 90 motors.
Logic Module Details.

Controls
Water
Differential Enthalpy High Exhaust Fan Shutdown and Air
Model DCV CO2 Limit Setpoint Change Purge Motors Controlled Model Number
Standard
H705a No No None None No No Series 90 H705A1003
W7459 No No No None No No M7415 W7459A1001
Yes W7459D1005

Building Automation
W7210 No No No None No No Series 72 W7210A1001
Yes W7210D1005
Advanced
W7212 Yes No No Adjustable No No Series 72 W7212A1009,
W7212A1041 or
W7212C1000c,d
W7213/14b Yes No No Adjustable No No Series 72 W7213A1008b
W7214A1007b
W7215 Yes No No Adjustable Yes Yes Series 72 W7215A1006

Components
Commercial
Yes Fixed No W7215B1004
W7460 Yes No No Adjustable Yes Yes M7415 W7460A1008
Yes Fixed No W7460B1006
a The H705 includes a SPDT logic module and C7400 sensor (both affixed to the mounting plate).
b
Terminals B-B1 (W7213) for heat pump applications, terminals 0-01 (W7214) for heat pump applications.
c
Use C7400C with W7212C; Use C7400A with W7212A
d W7212C has A, B, C, D and E enthalpy curves
Sensor Details
Pneumatic Controls

Model Number
Model Sensor of Details Comments No Display Display
C7046 Temperature Discharge or Mixed Air Probe with flange C7046A1004 —
C7150 Thermistor on board C7150B1004 —
C7400A Enthalpy Changeover Use with W7212A C7400A1004 —
C7400C Use with W7212C C7400C1002 —
C7660 Dry Bulb Temperature Use for single dry bulb only. C7660A1000 —
Industrial Combustion

Wall Mount Outputs: one relay, one 0/2-10 Vdc analog or C7232A1016 C7232A1008
C7232 CO2 4-20 mA
Duct Mount C7232B1014 C7232B1006
Controls

Wall Mount Outputs: one fixed 0-10 Vdc analog C7632A1004 —


C7632 CO2 (fixed 0-2000 ppm)
Duct Mount C7632B1002 —

70-6910 435
Economizer Controllers and Logic Modules
H705 Solid State Enthalpy Controller
The H705 Solid State Enthalpy Controller maximizes the use of free
outdoor air in place of the first stage of cooling in heating,
ventilating and air conditioning (HVAC) economizer systems.
• Consists of a W7459A type solid state economizer logic module and
a C7400A Solid State Enthalpy Sensor on a mounting plate.
• Mounts in any position in outdoor air duct.
• Use enthalpy setpoint to select desired combination of air
temperature and humidity.
• Use a second C7400A Sensor for differential changeover control to
maximize savings.
• Maximizes use of outdoor air for free cooling.
• Use in electronic and electromechanical systems.

Dimensions, Approximate: 4 3/4 in. high x 6 in. wide x 2 1/2 in. deep Approvals:
(120 mm high x 154 mm wide x 80 mm deep) Underwriters Laboratories, Inc. Component UL plastic rated for UL 94
Contact Ratings: 1.5 A Run @ 24 Vac; 3.5 A Inrush @ 24 Vac V-0
Voltage: 20-28V at 60 Hz; 20-26V at 50 Hz
Frequency: 50 Hz; 60 Hz
Accessories:
4074EJM 1.2K ohm checkout resistor, 620 ohm resistor, and jumper
Operating Temperature Range: 45 F to 95 F (7 C to 35 C)
S963B1128 Manual Potentiometer (135 ohm)
Operating Humidity Range (% RH): 20 to 90% RH

Product Number Description Comments Used With


H705A1003 Includes W7459 and C7400A SPDT - terminals 1 and 2 make with enthalpy increase above setpoint; Series 90 motors
terminals 2 and 3 make with enthalpy decrease.

W7210 Solid State Economizer Logic Modules


W7210A,D Solid State Economizer Logic Modules are used with
solid state C7400A Enthalpy Sensors or C7660 Dry Bulb
Temperature Sensors and Honeywell Series 72 actuators to
proportion outdoor and return air dampers for economizer control
in commercial HVAC equipment.
• Operates from the commercial thermostat to provide a totally
integrated control system.
• Includes enthalpy or dry bulb changeover control, minimum damper
position potentiometer and compressor staging relay functions.
• Optional differential enthalpy control provides greater economizer
savings than single enthalpy control by selecting the most
economical air for cooling.
• Differential enthalpy control uses two sensor inputs, one in return air
and one in outdoor air then economizer control selects the air with
the lower enthalpy.
• Enthalpy setpoint (A-D) W7210 Solid State Economizer Logic
Module controls the combination of air temperature and humidity
suitable for free cooling.
• LED indicates when free cooling is available.
• Mount on the sheet metal duct.
• Mounting screws included.
Dimensions, Approximate: 5 3/16 in. high x 4 11/16 in. wide x 1 9/16 Used With: Honeywell Series 72 actuators
in. deep (119 mm high x 132 mm wide x 40 mm deep) Approvals:
Contact Ratings: 1.5 A Run @ 24 Vac; 3.5 A Inrush @ 24 Vac Underwriters Laboratories, Inc. Flammability Rating UL94V-5V
Voltage: 24 Vac
Frequency: 50 Hz; 60 Hz Accessories:
Operating Temperature Range: -40 F to +125 F (-40 C to +52 C) S963B1128 Manual Potentiometer (135 ohm)
Operating Humidity Range (% RH): 5 to 95% RH, non-condensing

Use with
Product Number Input Output Sensor Description Comments
W7210A1001 Dry Bulb Temperature sensor C7660, Two SPDT one C7400A; C7150; Series 72 Optional remote minimum position
or Enthalpy sensor C7400A, or 2-10Vdc C7046; C7660 Economizer potentiometer. Economizer Logic Module
Mixed Air Temperature sensor C7150 Logic Module operates Series 72 actuators.
W7210D1005 Dry Bulb Temperature sensor C7660, Two SPDT one C7400A; C7150; Series 72 High enthalpy limit.Optional remote
or Enthalpy sensor C7400A, or 2-10Vdc C7046; C7660 Economizer minimum position potentiometer.
Mixed Air Temperature sensor C7150 Logic Module Economizer Logic Module operates Series
72 actuators.

436 customer.honeywell.com 70-6910


Economizer Controllers and Logic Modules
W7212; W7213; W7214 Demand Control Ventilation Economizer

Controls
Home
Logic Modules
W7212, W7213, and W7214 Economizer Logic Modules are used
with C7232 Demand Control Ventilation (DCV) Sensors, and solid
state C7400 Enthalpy Sensors or C7660 Dry Bulb Temperature
Sensors. All models proportion outdoor and return air dampers for
control of free cooling in commercial HVAC equipment.

Indoor Air Quality


• Operates from commercial thermostat and DCV sensor to provide a
totally integrated control system.
• Mounts on M7215 Motor or ductwork.
• Used with Honeywell M7215 or Series 70 DCA.
• Combines minimum and DCV maximum damper position
potentiometers with compressor staging.
• Solid state enthalpy or dry bulb changeover control.
• Terminals included for connecting optional S963B1128 Remote
Potentiometer for remote minimum damper position control.

Combustion Controls
• LED indicates when free cooling is available.
• LED indicates when module is in DCV mode.

Residential
• LED indicates when exhaust fan contact is closed.
• W7213 is used with heat pump B terminal.
• W7214 is used with heat pump O terminal.

Dimensions in inches (millimeters) Contact Ratings: 1.5 A Run @ 30 Vac; 3.5 A Inrush @ 30Vac
Voltage: 24 Vac
Output: 2-10 Vdc to actuator

Hydronic Controls
4-3/8 (112)
Frequency: 50 Hz; 60 Hz
Operating Temperature Range: -40 F to +149 F (-40 C to +65 C)
Operating Humidity Range (% RH): 5 to 95% RH, non-condensing
1-5/8 Color: Black
(41)
Approvals:
Underwriters Laboratories, Inc. UL Listed File: E4436, Guide: XAPX,
CE Report: GV02-003, Meets UL873 plenum requirements, C-tick,
Complies with California Title 24
Accessories:

Controls
C7232A1008 Wall mounted Non-dispersive Infrared (NDIR) Carbon

Water
2-1/16 Dioxide Sensor with LCD Display and Honeywell logo
(53)
C7232A1016 Wall mounted Non-dispersive Infrared (NDIR) Carbon
1-15/16
Dioxide Sensor with Honeywell logo
(49)
C7232B1006 Duct mounted Non-dispersive Infrared (NDIR) Carbon
Dioxide Sensor with LCD Display and Honeywell logo
4-1/8
(104)
C7232B1014 Duct mounted Non-dispersive Infrared (NDIR) Carbon
Dioxide Sensor with Honeywell logo

Building Automation
C7632A1004 Wall mounted Non-dispersive Infrared (NDIR) Carbon
Dioxide Sensor with Honeywell logo
C7632B1002 Duct mounted Non-dispersive Infrared (NDIR) Carbon
Dioxide Sensor with Honeywell logo
S963B1128 Manual Potentiometer (135 ohm)

1/8 (4)
2-5/8 (66) M20578B

Components
Commercial
Use with
Product Number Input Sensor Description Comments Used With
W7212A1009 Dry Bulb Temperature C7232; Series 72 Economizer Can be used with C7400A Enthalpy sensors or C7232; C7632;
sensor: C7660; C7400A; Logic Module with C7660 Dry Bulb sensor and C7232 CO2 sensors for Honeywell Series
Mixed Air Temperature C7150 Demand Control Demand Control Ventilation. Accepts inputs from 72 actuators
sensor: C7150; Ventilation discharge or mixed air temperature sensors.
CO2 sensor: C7233; Economizer Logic Module operates Series 72
Enthalpy Sensor: C7400A actuators. Default minimum position in freeze
Pneumatic Controls

protection
W7212A1041 Dry Bulb Temperature C7232; Series 72 Economizer Can be used with C7400A Enthalpy sensors or C7232; C7632;
sensor: C7660; C7400A; Logic Module with C7660 Dry Bulb sensor and C7232 CO2 sensors for Honeywell Series
Mixed Air Temperature C7150 Demand Control Demand Control Ventilation. Accepts inputs from 72 actuators;
sensor: C7150; Ventilation discharge or mixed air temperature sensors. M7215
CO2 sensor: C7233; Economizer Logic Module operates Series 72
Enthalpy Sensor: C7400A actuators. Default closed position in freeze protection
W7212C1000 Dry Bulb Temperature C7232; Series 72 Economizer Can be used with C7400C Enthalpy sensors or C7232; C7632;
sensor: C7660; C7400C; Logic Module with C7660 Dry Bulb sensor and C7232 CO2 sensors for Honeywell Series
Industrial Combustion

Mixed Air Temperature C7150 Demand Control Demand Control Ventilation. Accepts inputs from 72 actuators;
sensor: C7150; Ventilation with discharge or mixed air temperature sensors. M7215
CO2 sensor: C7233; additional “E” Economizer Logic Module operates Series 72
Controls

Enthalpy Sensor: C7400C; actuators.Default minimum position in freeze


protection. Additional "E" enthalpy curve

70-6910 437
Economizer Controllers and Logic Modules
Use with
Product Number Input Sensor Description Comments Used With
W7213A1008 Dry Bulb Temperature C7232; Series 72 Economizer Can be used with C7400A Enthalpy sensors or C7232; C7632;
sensor: C7660; C7400A; Logic Module with C7660 Dry Bulb sensor and C7232 CO2 sensors for Honeywell Series
Mixed Air Temperature C7150 Demand Control Demand Control Ventilation. Accepts inputs from 72 actuators
sensor: C7150; Ventilation and B-B1 discharge or mixed air temperature sensors.
CO2 sensor: C7233; terminals for heat Economizer Logic Module operates Series 72
Enthalpy Sensor: C7400A pump actuators.Default closed position in freeze protection.
Includes B terminal (energized in heating mode)
W7214A1007 Dry Bulb Temperature C7232; Series 72 Economizer Includes O terminal (energized in cooling mode).Can C7232; C7632;
sensor: C7660; C7400A; Logic Module with be used with C7400A Enthalpy sensors or C7660 Honeywell Series
Mixed Air Temperature C7150 Demand Control Dry Bulb sensor and C7232 CO2 sensors for 72 actuators
sensor: C7150; Ventilation and O-O1 Demand Control Ventilation. Accepts inputs from
CO2 sensor: C7233; terminals for heat discharge or mixed air temperature sensors.
Enthalpy Sensor: C7400A pump Economizer Logic Module operates Series 72
actuators. Default closed position in freeze protection

W7215A,B; W7460 Enhanced Economizer Logic Modules


economizer and ventilation control in commercial HVAC
equipment. (See below)
• Input from DCV C02 sensor provides optimum ventilation based on
occupancy.
• All models include air change and shutdown; "A" models also
provide prepurge.
• Demand control ventilation economizer provides comfort, energy
savings, reliability, air quality compliance and application flexibility in
heating, cooling and ventilating applications.
• Combines solid state enthalpy or dry bulb changeover control,
minimum and maximum damper position potentiometer and DCV
setpoint functions.
• Optional differential enthalpy control (enthalpy setpoint D with two
C7400A sensors) provides greater economizer savings and
maximum comfort over single enthalpy control by selecting the most
economical method for cooling.
Use with C7400A, or C7660 and C7150B or C7046 Sensors; • Enthalpy setpoint (A-D) on economizer module controls the
Demand Control Ventilation (DCV) sensor C7232 C02 sensor (2-10 combination of air temperature and humidity that is suitable for free
Vdc); and Honeywell Series 72 actuators, or M7415 Damper cooling.
Actuator to proportion outdoor and return air dampers for • LEDs indicates when economizer is in free cooling and DCV modes.
• B models provide for input from an outdoor air quality sensor.
Dimensions, Approximate: 8 11/16 in. high x 5 13/16 in. wide x 1 11/ Approvals:
16 in. deep (221 mm high x 147 mm wide x 43 mm deep) Underwriters Laboratories, Inc. UL Listed File: E4436, Guide: XAPX,
Contact Ratings: 1.5 A Run @ 30 Vac; 3.5 A Inrush @ 30Vac CE Report: GV02-003, Meets UL873 plenum requirements, C-tick,
Voltage: 24 Vac Complies with California Title 24
Frequency: 50 Hz; 60 Hz
Operating Temperature Range: -25 F to +125 F (-32 C to +52 C)
Accessories:
4074EJM 1.2K ohm checkout resistor, 620 ohm resistor, and jumper
Operating Humidity Range (% RH): 5 to 95% RH, non-condensing
S963B1128 Manual Potentiometer (135 ohm)
Used With: Honeywell Series 72 actuators

Product Number Input Output Use with Sensor Description Comments


W7215A1006 Discharge Air 2-10 Vdc to C7232; C7400A; Series 72 Economizer Logic Can accept remote minimum position
Temperature sensor: actuator C7150; C7046; Module with analog input from damper position potentiometer and/or
C7150 or C7046; C7660 one Indoor Air Quality sensor analog input from one carbon dioxide sensor
Air Quality Sensor (commonly Carbon Dioxide for indoor air. Economizer Logic Module
Sensor) operates Series 72 actuators.
W7215B1004 Discharge Air 2-10 Vdc to C7232; C7400A; Series 72 Economizer Logic Can accept remote minimum position
Temperature sensor: actuator C7150; C7046; Module with analog input from damper position potentiometer and/or
C7150 or C7046; C7660 two Indoor Air Quality sensors analog input from two carbon dioxide
Air Quality Sensor (commonly Carbon Dioxide sensors for indoor and outdoor air.
Sensor) Economizer Logic Module operates Series
72 actuators.

438 customer.honeywell.com 70-6910


Economizer Controllers and Logic Modules
W7459 Solid State Economizer Logic Module

Controls
Home
W7459 Solid State Economizer Logic Module are used with M7415
and M8405 Dedicated Economizer Actuators to proportion outdoor
and return air dampers in economizer systems.
• Attaches to one side of actuator for proportional control of damper.
• Combines solid state changeover control, minimum damper position
potentiometer and compressor staging relays.
• Use one sensor in outdoor air for single sensor control; use two

Indoor Air Quality


sensors, one in return air and one in outdoor air, for differential
control.

Dimensions, Approximate: 4 1/16 in. high x 2 13/16 in. wide x 1 1/4 in.
deep (103 mm high x 71 mm wide x 32 mm deep)
Contact Ratings: 1.5 A Run @ 24 Vac; 3.5 A Inrush @ 24 Vac
Voltage: 24 Vac
Frequency: 50 Hz; 60 Hz
Output: Output for M7415

Combustion Controls
Operating Temperature Range: -40 F to +125 F (-40 C to +52 C)

Residential
Operating Humidity Range (% RH): 5 to 95% RH, non-condensing
Approvals:
Underwriters Laboratories, Inc. UL Listed File: E4436, Guide:
XAPX2, CE Report: GV97-010, Flammability Rating UL94V-5V
Accessories:
4074EJM 1.2K ohm checkout resistor, 620 ohm resistor, and jumper
S963B1128 Manual Potentiometer (135 ohm)

Hydronic Controls
Use with
Product Number Input Sensor Comments Used With
W7459A1001 Y1 and Y2 from thermostat; Discharge C7400A; C7150; Optional remote minimum position potentiometer. M7415 Damper
Air Temperature sensor: C7150 or C7046; C7660 Actuator
C7046;
Enthalpy Sensor: C7400A
W7459A1035 See commentsY1 and Y2 from C7400A; C7150; Optional remote minimum position potentiometer. With M7415 Damper
thermostat C7046; C7660 resistor jumper to allow operation with a temperature Actuator
activated switch to limit minimum position to 50% max. open.
W7459C1007 Discharge Air Temperature controller: C7400A; C7150; — M8405 Damper

Controls
Water
T675 or T6031 C7046; C7660 Actuator
W7459D1005 Y1 and Y2 from thermostat; Discharge C7400A; C7150; High enthalpy limit. M7415 Damper
Air Temperature sensor: C7150 or C7046; C7660 Actuator
C7046;
Enthalpy Sensor: C7400A

Building Automation
W7499 Solid State Economizer Logic Module
W7459 Solid State Economizer Logic Module with M7415 Actuator
to proportion outdoor and return air dampers in economizer
systems.
• Combines solid state changeover control, minimum damper position
potentiometer and compressor staging relays.
• Use one sensor in outdoor air for single sensor control; use two
sensors, one in return air and one in outdoor air, for differential
control.

Components
Commercial
Dimensions, Approximate: 5 in. high x 6 in. wide x 5 in. deep (103 mm
high x 71.4 mm wide x 33 mm deep)
Contact Ratings: 1.5 A Run @ 30 Vac; 3.5 A Inrush @ 30Vac
Voltage: 24 Vac
Frequency: 50 Hz; 60 Hz
Operating Temperature Range: -40 F to +125 F (-40 C to +52 C)
Operating Humidity Range (% RH): 5 to 95% RH, non-condensing
Approvals:
Pneumatic Controls

Underwriters Laboratories, Inc. UL Listed File: E4436, Guide:


XAPX2, Flammability Rating UL94V-5V

Product Number Use with Sensor Description Comments


W7499A1003 May add a second C7400 sensor for differential W7459A1001 Economizer Logic Module Kit includes W7459A1001 Economizer Logic
control, C7400A, C7150, C7046, C7660 with M7415A1006 Damper Actuator Module and M7415A1006 Damper Actuator
Industrial Combustion
Controls

70-6910 439
Economizer Controllers and Logic Modules
W859 Economizer Control Packages
Contain all controls needed to operate an outdoor return air
damper system, when used with an M91XX Modutrol IV Motor with
internal balancing relay.
• Can be connected to the commercial thermostat to provide a totally
integrated control system that locks out the economizer during the
heating system.
• Used with an H205A or H705A Enthalpy Control to provide
maximum economy in high humidity areas.
• Includes lead wires for remote minimum position potentiometer and
remote changeover switch. 24 Vac power supply only.
• Mounts in place of Modutrol IV Motor cover, when used with
203977A bracket.
• Weatherproof screw-on caps prevent accidentally changing control
adjustments.
• Hook provided to support device on side of Modutrol IV Motor during
wiring.

Dimensions, Approximate: 5 13/16 in. high x 4 1/8 in. wide x 3 11/32 Approvals:
in. deep (148 mm high x 105 mm wide x 85 mm deep) Underwriters Laboratories, Inc. UL and CSA recognized for field
Contact Ratings: 1 A @ 24 Vac wiring.
Voltage: 24 Vac
Frequency: 50 Hz; 60 Hz
Accessories:
107324A Capillary Holder Assembly for duct insertion, 8 3/8 in. long
Replacement Parts:
107324A Capillary Holder Assembly for duct insertion, 8 3/8 in. long

Product Number Output Comments Used With


W859F1005 Series 90 throttling range: 10 F (6 C) Requires 203977A bracket for mounting on Modutrol IV M91XX Modutrol IV motor
motor.135 ohm mixed air temperature controller
W859F1013 Series 90 throttling range: 10 F (6 C) Requires 203977A bracket for mounting on Modutrol IV M91XX Modutrol IV motor, and
motor.135 ohm mixed air temperature controller H705A1003 enthalpy control
W859F1021 Series 90 throttling range: 10 F (6 C) Requires 203977A bracket for mounting on Modutrol IV M91XX Modutrol IV motor, and
motor.135 ohm mixed air temperature controller H705A1003 enthalpy control

Economizer Parts and Accessories


Product Number Description Used With
4074EJM 1.2K ohm checkout resistor, 620 ohm resistor, and jumper W7459; W7210; W7212; W7215
4074EJQ Board for panel mounting W7459A W7459A

440 customer.honeywell.com 70-6910


Economizer Damper Actuators
M6415; M7215; M7415; M8405; M8415 Economizer Damper Actuators

Controls
Home
25 lb-in. spring return damper actuators provide two-position,
three-position, floating, or modulating control of economizer
systems, ventilation dampers and combustion air dampers used in
residential or commercial HVAC equipment.
• Synchronous Motor. Quiet, high efficiency drive motor.
• Spring returns motor shaft to normal position in the event of power
failure.

Indoor Air Quality


• High impact, glass-fiber reinforced plastic case is rugged, lightweight
and corrosion resistant.
• Uses Q298B Linkage.

Dimensions in inches (millimeters)

Combustion Controls
4-1/2 (114)

Residential
1/4 (6)

4-1/32 1-3/8 (35)


(102)
4-1/2
(114)
4-1/2 3-1/8 (79)
(114)

Hydronic Controls
(127)

2-1/4 (57)
7/16 3-1/2 (89) 1-1/4
(11) (32)
5-3/16 (132)
TOP VIEW SIDE VIEW POWER END VIEW M3851

Dimensions, Approximate: 4 1/2 in. high x 5 in. wide x 5 3/16 in. deep Nominal Spring Return (seconds): 18 sec
(114 mm high x 127 mm wide x 132 mm deep) Nominal Timing Opening (seconds): 90 sec
Fail Safe Mode: Spring Return Maximum Run Time (seconds): 90 sec
Torque Rating: 25 lb-in. (2.8 Nm) Minimum Timing (seconds): 90 sec

Controls
Water
Torque Rating, Breakaway: 40 lb-in. (4.5 Nm) Deadweight Load on Shaft (Power End): 15 lbs max
External Auxiliary Switches Available: Yes Operating Temperature Range: -25 F to +125 F (-32 C to +52 C)
Fixed Stroke: Yes Shipping Temperature Range: -30 F to +150 F (-34 C to +66 C)
Motor Shafts: 1 Operating Humidity Range (% RH): 5 to 95% RH, non-condensing
Feedback: No Materials (Housing): UL94-5V plastic housing
Electrical Connections: Quick-connect terminals Weight: 3 lb
Frequency: 50 Hz; 60 Hz

Building Automation
Approvals:
Mounting: Foot-mounted Underwriters Laboratories, Inc. Listed File: E4436, Guide: XAPX
Vibration: V2 level
Angle of Rotation (Stroke Max (deg)): 90

Power Consumption
Control Rotation
Product Number Signal (Driving) (Holding) to Open Description Comments Used With
M6415A1016 Floating, 8 VA 3 VA CCW Spring return-foot mounted, — Floating Controllers—
SPDT Spdt floating, 24 Vac
M7215A1008 2 to 10 Vdc 8 VA 3 VA CCW Spring return-foot mounted, — W7212/13/14 Economizers;

Components
Commercial
Modulating, 24 Vac W7215 Economizers
M7415A1006 Thermistor, 8 VA 5 VA CCW Spring return-foot mounted, With captive W7459 Economizers;
Modulating Modulating, 24 Vac mounting nuts W7460 Economizers
M7415B1004 Thermistor, 8 VA 5 VA CW Spring return-foot mounted, — W7459 Economizers;
Modulating Modulating, 24 Vac W7460 Economizers
M8405A1006 Three position 8 VA 3 VA CCW Spring return-foot mounted, — W7459C—
3 position w/field adj. min
Pneumatic Controls

pos., 24 Vac
M8415A1004 Two position, 8 VA 3 VA CCW Spring return-foot mounted, — —
SPST 2 position, 2 wire w/field adj.
min. pos., 24 Vac
Industrial Combustion
Controls

70-6910 441
Economizer Damper Actuators
Q769 Signal Adapters
Q769 Adapter is used to provide a modulating signal to the M7415
Economizer Damper Motors when used with a controller.

Dimensions, Approximate: 1 3/8 in. high x 1 3/8 in. wide x 11/16 in.
deep (35 mm high x 35 mm wide x 17 mm deep)
Electrical Connections: Quick-connect terminals
Operating Temperature Range: -25 F to +125 F (-32 C to +52 C)

MIN
POSN P1
P

6V to
9V

PUSH Q769 ONTO


M3853A M7415 ACTUATOR

Product Number Control Signal Description Used With


Q769A1009 6 to 9 Vdc 6 to 9 volt Adapter M7415
Q769B1008 4 to 20 mA 4 to 20 mA Adapter M7415
Q769C1007 0 to 10 Vdc 0-2 to 10 Vdc Adjustable Adapter M7415

Economizer Actuator Accessories


Product Number Description Used With
203977A Economizer Adapter Kit for Mod Motors Modutrol™ Motors; W7459 Economizers
4074EGR Crank arm assembly M6415; M7215; M7415; M8405; M8415

4074EKV 24 Vac Auxiliary switch which provides switching M6415; M7215; M7415; M8405; M8415
capability for controlling auxiliary equipment

7640QF Terminal Enclosure which provides wiring enclosure for M6415; M7215; M7415; M8405; M8415
electrical connections

7640 QF M11519A

Q709A1005 Minimum Position Potentiometer M7415; M7405

442 customer.honeywell.com 70-6910


Economizer Sensors
C7150 Mixed Air Sensor

Controls
Home
C7150 Solid State mixed air sensor is used with Honeywell
economizer logic modules and W973 and M7415 to proportion
outdoor and return air dampers in economizer systems.
• Uses thermistor sensing element in ventilation duct systems.
• Negative temperature coefficient (NTC) causes resistance to
decrease as sampled air temperature increases.
• Resistance change used as in input to control W973 and M7415.

Indoor Air Quality


• Requires no settings or calibration.
• Mounts on duct surface with four screws (not supplied).

Application: Temperature Mixed Air Electrical Connections: 1/4 in. (6 mm) quick-connect terminals.
Dimensions, Approximate: 2 in. high, 2 1/2 in. wide, 3/4 in. deep (51
Approvals:

Combustion Controls
mm high x 64 mm wide) CE: Report: GV97-011
Sensor Type: 3000 ohms @ 25C NTC Underwriters Laboratories, Inc. Component Recognized

Residential
Color: Black
Operating Temperature Range: 40 F to 110 F (4 C to 43 C)

Maximum Ambient
Temperature
Product Number Mounting (F) (C) Used With
C7150B1004 Mount on a mounting bracket (not included) inside the 250 F 121 C W973 and M7415; W7210, W7212, W7213,

Hydronic Controls
mixed air or discharge air duct. W7214, W7215, W7459, W7460

C7400 Enthalpy Sensor


C7400 Solid State Enthalpy Sensor is used with Honeywell
economizer logic modules to proportion outdoor and return air
dampers in economizer systems.
• C7400 solid state elements sense enthalpy (temperature and
humidity); use two sensors for differential control, maximizing energy
savings.

Controls
• Use one sensor in outdoor air for single sensor control; use two

Water
sensors, one in return air and one in outdoor air, for differential
control.
• C7400 mount in any position up to 200 ft (61 m) away from
Economizer Logic Module.
• UL94-5V enclosure.

Building Automation
Application: Enthalpy economizing Approvals:
Dimensions, Approximate: 3 5/32 in. high, 3 7/8 in. wide, 1 in. deep CE: Report: GV97-011
(80 mm high x 98 mm wide x 25 mm deep) Underwriters Laboratories, Inc. Component Recognized: E4436
Sensor Type: 4-20 mA output
Color: Black
Accessories:
4074EJM 1.2K ohm checkout resistor, 620 ohm resistor, and jumper
Operating Temperature Range: -25 F to +125 F (-32 C to +52 C)
4074EJQ Board for panel mounting W7459A
Operating Humidity Range (% RH): 10 to 90% RH
S963B1128 Manual Potentiometer (135 ohm)
Electrical Connections: Two 1/4 in. quick-connect terminals

Maximum Ambient

Components
Commercial
Temperature
Product Number Mounting (F) (C) Used With
C7400A1004 Mounted in any position where it is exposed to freely 250 F 121 C W7210, W7212A, W7213, W7214, W7215,
circulating air W7459, W7460
C7400C1002 Mounted in any position where it is exposed to freely 250 F 121 C W7212C
circulating air
Pneumatic Controls
Industrial Combustion
Controls

70-6910 443
Economizer Sensors
C7650 Dry Bulb Sensor - for Differential Dry Bulb applications
C7650 Solid State Temperature Sensor is used with Honeywell
economizer logic modules to proportion outdoor and return air
dampers in economizer systems. For use in differential dry bulb
applications.
• C7650 solid state element senses temperature.
• Use two sensors, one in return air and one in outdoor air, for
differential control. For single dry bulb applications use C7660.
• C7650 mount in any position up to 200 ft (61 m) away from W7459.
• UL94-5V enclosure.

Application: Temperature economizing Approvals:


Dimensions, Approximate: 3 5/32 in. high, 3 7/8 in. wide, 1 in. deep CE: Report: GV97-011
(80 mm high x 98 mm wide x 25 mm deep) Underwriters Laboratories, Inc. Component Recognized: E4436
Sensor Type: 10-20 mA inversely proportional
Color: Black
Accessories:
4074EJM 1.2K ohm checkout resistor, 620 ohm resistor, and jumper
Operating Temperature Range: 40 F to 100 F (4 C to 38 C)
4074EJQ Board for panel mounting W7459A
Electrical Connections: Two 1/4 in. quick-connect terminals
S963B1128 Manual Potentiometer (135 ohm)

Product Number Application Type Mounting Description Used With


C7650A1001 Duct outside, one in Mounted in any position Dry Bulb Temperature Sensor for supply duct or return W7210, W7212, W7213,
return air and one in where it is exposed to freely air with a 10-20 mA inversely proportional sensor - for W7214, W7215, W7459,
outdoor air circulating air differential dry bulb applications W7460

C7660 Selectable Temperature Sensor


C7660 Selectable Temperature Sensor is used with the W7459,
W7215, W7212, W7213 and W7214 Economizer Controls. The
economizer controls are mounted on an M7415/M7215 Actuator.
They permit the use of outdoor air as the first stage of cooling in
heating, ventilating and air conditioning (HVAC) systems. The
C7660 Selectable Temperature Sensor is only to be used with
single temperature change over with the sensor located in the
outdoor air.
• Senses temperature of outdoor air and provides a signal to
economizer control with OK or not OK to economize.
• Selectable dip switch provides 8 change over temperature options.
• When temperature of outdoor air is below change over temperature,
the outdoor air damper is opened to reduce the cooling load in the
building.
• Provides 4 OR 20 mA output signal to economizer control;
At 4 mA not OK to economize, at 20 mA OK to economize.
• Highly accurate microprocessor control.
• Sensor is enclosed in a rugged, corrosion-resistant plastic case.
• Replaces C7650 temperature sensors and the control function of
temperature change over in the economizer control.
Application: Selectable Temperature Sensor Operating Temperature Range: -40 to 149 F (-40 to 65 C)
Dimensions, Approximate: 4 5/32 in. high x 3 7/8 in. wide x 1 in. deep Electrical Connections: Two 1/4 in. quick-connect terminals
(81 mm high x 96 mm wide x 25 mm deep)
Approvals:
Sensor Type: 4 or 20mA Output Underwriters Laboratories, Inc. Flammability Rating 94-5V (C-UL)
Color: Black

Product Number Application Type Mounting Used With


C7660A1000 Duct outside (supply) or Mounted in any position where it is exposed to W7210, W7212, W7213, W7214, W7215, W7459,
return freely circulating air W7460

444 customer.honeywell.com 70-6910


Modutrol IV™ Motors
Modutrol IV™ Series 2 and Series 3 Family of Motors

Controls
Home
“Contractor-Friendly” design for service and retrofit

Indoor Air Quality


INTERNAL
FIELD-ADDABLE

Combustion Controls
TRANSFORMER

Residential
INTERNAL
FIELD-ADDABLE
AUXILIARY
SWITCHES

Hydronic Controls
CONTROLLER
RESISTOR CRANK INTERFACE
BOARD ARM MODULE M27252

Modutrol IV™ Series 2 and Series 3 Motors replace all present 3. Brushless DC sub motor provides a fixed torque over the entire
generation Modutrol motors and set a new, certifiable standard for the voltage range.
industry. Modutrol IV™ Series 2 and Series 3 Motors retain all the
4. Reduced power consumption. Motor power needs can always be

Controls
features that make Honeywell Modutrol motors the most reliable

Water
produced, and go even further with many quality improvements. satisfied with a 25 VA transformer.
Our engineers have incorporated Design for SIx Sigma methodology 5. Internal quality improvements. Results in improved performance
and Electronic Excellence to re-engineer this popular product. The and longer life. These quality improvements include:
motor has undergone a technology update integrating the proven DCA •Microprocessor based technology eliminated the need for
(Direct Coupled Actuator) microprocessor based design into the existing mechanical end stops.
footprint of a Mod Motor. •Brushless DC sub motor eliminates the need for oil.

Building Automation
The Series 2 and Series 3 Motors provide these features and
benefits: 6. Auxiliary Switch cams. All models have auxiliary switch cams that
1. Dual shafts. Slotted and tapped at both ends. Both drive and auxil- permit acceptance of 220736A,B Internal Auxiliary Switch Kits.
iary shafts have equal torque ratings, allowing auxiliary shaft to drive
full torque loads. This provides a more flexible motor. For example, a 7. Field Adjustable stroke. Most models are field adjustable (i.e. 90 to
spring-return, normally closed motor will provide normally open oper- 160 degrees).
ation simply by using the auxiliary shaft.
TRADELINE motors and appropriate accessories can be configured
2. NEMA 3 housing. Modutrol IV™ motor housings protect the motor to replace all previous Honeywell Modutrol motors, as well as most
from driving rain if motor is mounted in the upright position (as OEM modutrol motors. The appropriate accessories are listed with the
shown in above photo). May be mounted outdoors without a weath- different models and in tables near the end of this section.

Components
Commercial
erproofing kit.

Pneumatic Controls
Industrial Combustion
Controls

70-6910 445
Modutrol IV™ Motors
Modutrol IV™ Family of Motors
The following Modutrol IV™ motors can replace the old style Modutrol motors as shown below.

Mod IV Replacement Old Motors Replaced

Non- M6184 M9164 M644 M734


Spring M6194 M9174 M744 M934
Return M6284 M9184 M941
M6294 M9194 M944
M7164 M9484 M954
M7284 M9494
M7294

Spring M4185 M7685 M445


Return M6285 M8185 M745
M7285 M9185 M845
M7286 M945
M955

Medium M9175 M765


Torque M865
Spring M965
Return M975

The Honeywell Family of Modutrol IV™ Series 2 and Series 3 Motors


Voltage Vac Control Input Torque (lb-in.)
SPDT Spring
Actuator 24a 120 230 Stroke Timing On/Off Floating Modulating 35 60 75 150 300 Return Recommended Controller
*TRADELINE models.
M4185A1001 90-160 30-60 T775; T4031
M4185B1009 90-160 30-60 T775; T4031
M4185B1058 90-160 30-60 T775; T4031
M4185C1001 90-160 30-60 T775; T4031
M6184A1015 90-160 30-60 T775; T675; T678; T6031
M6184A1023 90-160 15-30 T775; T675; T678; T6031
a All 24 Vac Modutrol motors have CE approval.
b Available only through Honeywell Authorized Distributors.
c Includes minimum position potentiometer.

446 customer.honeywell.com 70-6910


Modutrol IV™ Motors

Controls
Voltage Vac Control Input Torque (lb-in.)

Home
SPDT Spring
Actuator 24a 120 230 Stroke Timing On/Off Floating Modulating 35 60 75 150 300 Return Recommended Controller
*TRADELINE models.
M6184D1001 90-160 15-30 T775; T675; T678; T6031
*M6184D1035 90-160 30-60 T775; T675; T678; T6031

Indoor Air Quality


M6184D1068 90-160 120-240 T775; T675; T678; T6031
M6184F1014 90-160 30-60 T775; T675; T678; T6031
*M6194B1011 90-160 60-120 T775; T675; T678; T6031

*M6194D1017 90-160 120-240 T775; T675; T678; T6031


M6194E1006 90-160 120-240 T775; T675; T678; T6031
M6284A1055 90-160 30-60 T775; T675; T678; T6031

Combustion Controls
M6284A1071 90-160 30-60 T775; T675; T678; T6031

Residential
*M6284D1000 90-160 30-60 T775; T675; T678; T6031

*M6284D1026 90-160 30-60 T775; T675; T678; T6031


M6284F1013 90-160 30-60 T775; T675; T678; T6031
*M6285A1005 90-160 30-60 T775; T675; T678; T6031
M6285C1001 90-160 30-60 T775; T675; T678; T6031
*M6294D1008 90-160 120-240 T775; T675; T678; T6031

Hydronic Controls
M7164A1017b 90-160 30-60 10.5-13.5 Vdc T775; W7080

M7164G1030b 90-160 30-60 10.5-13.5 Vdc T775; W7080

M7284A1004b 90-160 30-60 4-20 mA T775, EXCEL 5000

M7284A1012b 90-160 30-60 4-20 mA T775, EXCEL 5000

M7284A1038b 90-160 15-30 4-20 mA T775, EXCEL 5000

M7284A1079b 90-160 30-60 2-10 Vdc T775, EXCEL 5000

Controls
M7284C1000b 90-160 30-60 4-20 mA T775, EXCEL 5000

Water
M7284C1083 90 30 4-20 mA DDC
M7284C1091 160 60 4-20 mA DDC
M7284Q1009b 90-160 30-60 4-20 mA T775, EXCEL 5000
M7284Q1082 90 30 4-20 mA DDC

Building Automation
M7284Q1090 160 60 4-20 mA DDC
M7285A1003b 90-160 30-60 4-20 mA T775, EXCEL 5000

M7285A1045b 90-160 30-60 2-10 Vdc T775, EXCEL 5000

M7285C1009b 90-160 30-60 4-20 mA T775, EXCEL 5000

M7285Q1008b 90-160 30-60 4-20 mA T775, EXCEL 5000

M7286G1009b 90-160 30-60 2-10 Vdc T775, EXCEL 5000

M7294A1010b 90-160 60-120 2-10 Vdc T775, EXCEL 5000

Components
Commercial
M7294Q1007b 90-160 60-120 4-20 mA T775, EXCEL 5000

M7685A1025b,c 90-160 30-60 14-17 Vdc T775; W7080

*M8185D1006 90-160 30-60 T775


M9164A1005 90-160 30-60 135 ohm T775; T915; T991
M9164A1013 90-160 30-60 135 ohm T775; T915; T991
Pneumatic Controls

M9164A1070 90-160 30-60 135 ohm T775; T915; T991


M9164C1001 90-160 30-60 135 ohm T775; T915; T991
M9164C1068 90-160 30-60 135 ohm T775; T915; T991
*M9164D1009 90-160 30-60 135 ohm T775; T915; T991
M9174B1027 90-160 30-60 135 ohm T775; T915; T991
M9174C1025 90-160 30-60 135 ohm T775; T915; T991
Industrial Combustion

a
All 24 Vac Modutrol motors have CE approval.
b Available only through Honeywell Authorized Distributors.
Controls

c
Includes minimum position potentiometer.

70-6910 447
Modutrol IV™ Motors
Voltage Vac Control Input Torque (lb-in.)
SPDT Spring
Actuator 24a 120 230 Stroke Timing On/Off Floating Modulating 35 60 75 150 300 Return Recommended Controller
*TRADELINE models.
M9174C1033 90-160 30-60 135 ohm T775; T915; T991
*M9174D1007 90-160 30-60 135 ohm T775; T915; T991
M9184A1019 90-160 30-60 135 ohm T775; T915; T991
M9184C1031 90-160 30-60 135 ohm T775; T915; T991
M9184D1005 90-160 15-30 135 ohm T775; T915; T991
*M9184D1021 90-160 30-60 135 ohm T775; T915; T991
M9184F1034 90-160 30-60 135 ohm T775; T915; T991
M9185A1018 90-160 30-60 135 ohm T775; T915; T991
M9185C1006 90-160 30-60 135 ohm T775; T915; T991
*M9185D1004 90-160 30-60 135 ohm T775; T915; T991
M9185E1019 90-160 30-60 135 ohm T775; T915; T991
*M9194D1003 90-160 120-240 135 ohm T775; T915; T991
M9194E1000 90-160 120-240 135 ohm T775; T915; T991
a
All 24 Vac Modutrol motors have CE approval.
b
Available only through Honeywell Authorized Distributors.
c
Includes minimum position potentiometer.

Modutrol IV™ Series 2 and Series 3 Motor Order Number Guide


OUTPUT DRIVE
ROTATION ACTION SHAFT
4 NON-SPRING RETURN
5 N.O. SPECIFICATION
SPRING RETURN DUAL- NUMBER
6 N.O.

M9184D1021
ENDED
1 NON-SPRING RETURN SHAFT FURTHER
IDENTIFIES
2 N.O. SPRING RETURN
1 MOTOR

CONTROL SERIES (FIRST TWO DIGITS) TORQUE DESIGNATION SUFFIX LETTER APPLIES TO ALL MODELS
41 SERIES 40, TWO-POSITION, LINE VOLTAGE TORQUE NUMBER OF
61 SERIES 60, FLOATING CONTROL AUX. SWITCHES SPECIAL ELECTRICAL
SPRING NON-SPRING STROKE
62 SERIES 60, FLOATING WITH FEEDBACK FUNCTION ROTATION
RETURN RETURN 0 1 2
POTENTIOMETER
71 4-7, 6-9, 10.5-13.5 VDC CONTROL 6 35 LB-IN. A B C STANDARD
72 4-20 mA OR 2-10 VDC CONTROL ADJ. ZERO
7 75 LB-IN. Q
76 14-17 VDC WITH MINIMUM POSITION AND SPAN ADJUSTABLE N.O.
81 SERIES 80, TWO-POSITION, LOW VOLTAGE 8 60 LB-IN. 150 LB-IN. 2
MINIMUM
91 SERIES 90, PROPORTIONING CONTROL 1 V W POSITION
9 300 LB-IN.
94 PROPORTIONAL FLAME SAFEGUARD D STANDARD ADJUSTABLE
1 E F
FIRING RATE MOTOR N.O.
G STANDARD ADJUSTABLE

1 MODEL NUMBERS IN SHADED AREAS ARE AVAILABLE SPECIAL ORDER ONLY. CONTACT YOUR HONEYWELL SALES REPRESENTATIVE.

2 SUFFIX LETTERS IN BOLD ARE OBSOLETE. M13696A

448 customer.honeywell.com 70-6910


Modutrol IV™ Motors
M4185 Line Volt; M8185 Low Volt

Controls
Home
Two-Position Modutrol IV™ Series 2 Motors
Series 41 and Series 81 Modutrol IV™ motors are 2-position (line-
and low-voltage per motor control) spring-return motors. They are
used to operate dampers or valves in applications where it is
necessary or desirable to have the controlled element return to the
starting position in the event of power failure.

Indoor Air Quality


• Fixed torque throughout the entire voltage range.
• Integral spring return returns motor to normal position in the event of
power failure.
• Integral junction box provides NEMA 3 weather protection if motor is
mounted in the upright position.
• Motor and circuitry operate from 24 Vac.
• Quick-connect terminals are standard--screw terminal adapter is
available.
• Adapter bracket for matching shaft height of older motors is

Combustion Controls
available.
• Motors have field adjustable stroke (90 to 160 degrees).

Residential
• Motors are designed for either normally open or normally closed
valves and dampers.
• Integral auxiliary switches are available factory mounted, or can be
field added.
• Motors can operate valve linkages from the power end or auxiliary
end shafts for normally closed or normally open valve applications.
• All models have dual shafts (slotted and tapped on both ends).

Hydronic Controls
Application Type: Electric Approvals:
Fail Safe Mode: Spring Return CE: EN55011 (Emission) EN50082-2 (Immunity) 73/23/EEC (LVD)
Control Signal: Two position, SPST Underwriters Laboratories, Inc. Listed: File No. E4436, Guide No.
Feedback: No XAPX for USA and Canada
Frequency: 60 Hz; 50 Hz
External Auxiliary Switches Available: Yes
Accessories:
Q7230A1005 Interface module, provides adjustable zero & span,
Auxiliary Switch Ratings AFL - 120 Vac: 7.2A
voltage or current control
Auxiliary Switch Ratings ALR - 120 Vac: 43.2A
220736A Internal Auxiliary Switch Assembly - 1 Switch
Auxiliary Switch Ratings AFL - 240 Vac: 3.6A
220736B Internal Auxiliary Switch Assembly - 2 Switches
Auxiliary Switch Ratings ALR - 240 Vac: 21.6A
220738A Adapter Bracket. Adjusts shaft height to match Modutrol III
Electrical Connections: Quick-connect terminals
motors

Controls
Mounting: Foot-mounted

Water
220741A2-TP Screw Terminal Adapter Kit for 2 position Modutrol IV
Motor Shafts: Dual-ended shaft
Series 2 motors - Converts quick-connect terminals to screw terminals
Shaft Shape: square
221455A Infinitely adjustable Motor Crank Arm
Shaft Dimensions: 0.375 in. (10 mm)
50017460-001 24/120/230 Vac Internal Transformers for Series 2
Shaft Rotation (upon control signal increase):
Motors
Clockwise (as viewed from power end) (normally closed)
50017460-003 120 Vac Internal Transformers for Series 2 Motors
Deadweight Load on Shaft (Either End): 200 lbs.
4074ERU Weatherproofing kit. Protects motor from driving rain when

Building Automation
Deadweight Load (Combined on both Shafts): 300 lbs.
mounted in any position
Ambient Temperature Range: -40 F to +150 F (-40 C to +60 C)
Weight: 9.5 lb

Torque/Force Internal
Nominal Timing Auxiliary
Product Number (lb-in., lb) (Nm, N) Voltage (sec) Switch Stroke Includes
M4185A1001 60 lb-in. 6.8 Nm 120V 30-60 sec 0 Adjustable; 90 to 160 degrees Transformer
M4185B1009 60 lb-in. 6.8 Nm 120V 30-60 sec 1 Adjustable; 90 to 160 degrees Transformer
M4185B1058 60 lb-in. 6.8 Nm 24/120/230V 30-60 sec 1 Adjustable; 90 to 160 degrees Transformer

Components
Commercial
M4185C1007 60 lb-in. 6.8 Nm 120V 30-60 sec 2 Adjustable; 90 to 160 degrees Transformer
* M8185D1006 60 lb-in. 6.8 Nm 24V 30-60 sec 0 Adjustable; 90 to 160 degrees —
* TRADELINE models • SUPER TRADELINE models
Pneumatic Controls
Industrial Combustion
Controls

70-6910 449
Modutrol IV™ Motors
Dimensions in inches (millimeters)

TOP VIEW TOP VIEW OF BRACKET

4-7/8 4-1/4
(124) (107)

4-5/8
(116) 5-13/16
(148)
5-1/2
(140) 2-5/16
(58)

11/16
(17)

13/16 POWER END


1/4 (20)
(7) 1/4 (7)
13/16
2 (20) 4-7/8 (124)
4-1/16 (103) 1-1/2 (37) 5-9/16 (141)
4-1/16 (103)
1-1/2 (37)

JUNCTION
BOX

3/4
(19)

MOTOR
6-7/16
(164)

AUXILARY POWER 5-3/8


END END (137)
1 FOR 60 LB-IN. SPRING RETURN MODELS 8-3/4 (222);
2-9/16
(66) 2 FOR 60 LB-IN. SPRING RETURN MODELS (SHOWN).

9/16 (15)
1

ADAPTER 3/4
BRACKET (19) M18992A

450 customer.honeywell.com 70-6910


Modutrol IV™ Motors
M6184; M6194 Floating Modutrol IV™ Series 2 Motors

Controls
Home
Series 61 Modutrol IV™ Motors non-spring return floating control
motors used with controllers that provide a switched spdt or
floating output to operate dampers or valves.
• Integral junction box provides NEMA 3 weather protection if motor is
mounted in the upright position.
• Motor and circuitry operate from 24 Vac.
• Quick-connect terminals are standard--screw terminal adapter is

Indoor Air Quality


available.
• Adapter bracket for matching shaft height of older motors is
available.
• Motors have field adjustable stroke (90 to 160 degrees).
• Integral auxiliary switches are available factory mounted, or can be
field added.
• All models have dual shafts (slotted and tapped on both ends).
• All models have auxiliary switch cams.
• Fixed torque throughout the entire voltage range.

Combustion Controls
• Motors are designed for either normally open or normally closed
valves and dampers.

Residential
Application Type: Electric Ambient Temperature Range: -40 F to +150 F (-40 C to +60 C)
Fail Safe Mode: Non-Spring Return Weight: 6.5 lb
Control Signal: Floating
Approvals:
Feedback: No CE: EN55011 (Emission) EN50082-2 (Immunity) 73/23/EEC (LVD)
Frequency: 60 Hz; 50 Hz Underwriters Laboratories, Inc. Listed: File No. E4436, Guide No.
External Auxiliary Switches Available: Yes XAPX for USA and Canada
Auxiliary Switch Ratings AFL - 120 Vac: 7.2A

Hydronic Controls
Auxiliary Switch Ratings ALR - 120 Vac: 43.2A Accessories:
Auxiliary Switch Ratings AFL - 240 Vac: 3.6A Q7230A1005 Interface module, provides adjustable zero & span,
Auxiliary Switch Ratings ALR - 240 Vac: 21.6A voltage or current control
Electrical Connections: Quick-connect terminals 220736A Internal Auxiliary Switch Assembly - 1 Switch
Mounting: Foot-mounted 220736B Internal Auxiliary Switch Assembly - 2 Switches
Motor Shafts: Dual-ended shaft 220738A Adapter Bracket. Adjusts shaft height to match Modutrol III
Shaft Shape: square motors
Shaft Dimensions: 0.375 in. (10 mm) 221455A Infinitely adjustable Motor Crank Arm
Shaft Rotation (upon control signal increase): 50017460-001 24/120/230 Vac Internal Transformers for Series 2
Dependent on wiring (normally closed) Motors
Stroke: Adjustable; 90 to 160 degrees 50017460-003 120 Vac Internal Transformers for Series 2 Motors

Controls
Water
Deadweight Load on Shaft (Either End): 200 lbs. 4074ERU Weatherproofing kit. Protects motor from driving rain when
Deadweight Load (Combined on both Shafts): 300 lbs. mounted in any position

Torque/Force Internal
Nominal Timing Auxiliary
Product Number (lb-in., lb) (Nm, N) Voltage (sec) Switch Includes Comments

Building Automation
M6184A1015 150 lb-in. 17 Nm 24V 30-60 sec 0 — —
M6184A1023 75 lb-in. 8.5 Nm 120V 15-30 sec 0 Transformer —
M6184D1001 75 lb-in. 8.5 Nm 24V 15-30 sec 0 — —
* M6184D1035 150 lb-in. 17 Nm 24V 30-60 sec 0 — —
M6184D1068 150 lb-in. 17 Nm 24V 120-240 sec 0 — Contains on-off pulsing circuitry to
achieve timing.
M6184F1014 150 lb-in. 17 Nm 24V 30-60 sec 2 — —
M6194B1011 300 lb-in. 34 Nm 24V 60-120 sec 1 — —

Components
Commercial
* M6194D1017 300 lb-in. 34 Nm 24V 120-240 sec 0 — —
M6194E1006 300 lb-in. 34 Nm 24V 120-240 sec 1 — —
* TRADELINE models • SUPER TRADELINE models

Pneumatic Controls
Industrial Combustion
Controls

70-6910 451
Modutrol IV™ Motors
Dimensions in inches (millimeters)

TOP VIEW TOP VIEW OF BRACKET

4-7/8 4-1/4
(124) (107)

4-5/8
(116) 5-13/16
(148)
5-1/2
(140) 2-5/16
(58)

11/16
(17)

13/16 POWER END


1/4 (20)
(7) 1/4 (7)
13/16
2 (20) 4-7/8 (124)
4-1/16 (103) 1-1/2 (37) 5-9/16 (141)
3
4-1/16 (103)
1-1/2 (37)

JUNCTION
BOX

3/4
(19)

MOTOR
6-7/16
(164)
SPRING RETURN MODEL SHOWN
AUXILARY POWER 5-3/8
END END (137) 1 FOR 60 LB-IN. SPRING RETURN MODELS 8-3/4 (222).
FOR NON-SPRING RETUIRN MODELS 7-5/16 (185).
2-9/16
(66) 2 FOR 60 LB-IN. SPRING RETURN MODELS (SHOWN).

3 FOR NON-SPRING RETURN MODELS.

9/16 (15)
1

ADAPTER 3/4
(19) M18998B
BRACKET

452 customer.honeywell.com 70-6910


Modutrol IV™ Motors
M6284; M6294 Floating Modutrol IV™ Series 2 Motors,

Controls
Home
for Slaving Applications only
These Series 62 Modutrol IV™ Motors non-spring return floating
control motors are used with controllers that provide a switched
spdt or floating output to operate dampers or valves. These motors
also have an internal electrically isolated feedback potentiometer
that provides indication of the motor shaft position. Some models

Indoor Air Quality


can be used for slaving Series 90 Motors.
• Integral junction box provides NEMA 3 weather protection if motor is
mounted in the upright position.
• Motor and circuitry operate from 24 Vac.
• Quick-connect terminals are standard--screw terminal adapter is
available.
• Adapter bracket for matching shaft height of older motors is
available.
• Motors have field adjustable stroke (90 to 160 degrees).

Combustion Controls
• Integral auxiliary switches are available factory mounted, or can be
field added.

Residential
• All models have dual shafts (slotted and tapped on both ends).
• All models have auxiliary switch cams.
• Fixed torque throughout the entire voltage range.
• Motors are designed for either normally open or normally closed
valves and dampers.
• Include electrically isolated feedback potentiometer that provides
shaft position indication.
• -S models with non-linear feedback are for slaving applications only.

Hydronic Controls
Dimensions Diagram: See page 452

Application Type: Electric Approvals:


Fail Safe Mode: Non-Spring Return CE: EN55011 (Emission) EN50082-2 (Immunity) 73/23/EEC (LVD)
Control Signal: Floating Underwriters Laboratories, Inc. Listed: File No. E4436, Guide No.
Feedback: Yes XAPX for USA and Canada
Frequency: 60 Hz; 50 Hz
External Auxiliary Switches Available: Yes
Accessories:
Q7230A1005 Interface module, provides adjustable zero & span,
Auxiliary Switch Ratings AFL - 120 Vac: 7.2A
voltage or current control
Auxiliary Switch Ratings ALR - 120 Vac: 43.2A
220736A Internal Auxiliary Switch Assembly - 1 Switch
Auxiliary Switch Ratings AFL - 240 Vac: 3.6A

Controls
220736B Internal Auxiliary Switch Assembly - 2 Switches

Water
Auxiliary Switch Ratings ALR - 240 Vac: 21.6A
220738A Adapter Bracket. Adjusts shaft height to match Modutrol III
Mounting: Foot-mounted
motors
Motor Shafts: Dual-ended shaft
220741A2-62 Screw Terminal Adapter Kit for Series 62 Series Modutrol
Shaft Shape: square
IV Series 2 motors- Converts quick-connect terminals to screw
Shaft Dimensions: 0.375 in. (10 mm)
terminals
Shaft Rotation (upon control signal increase):
221455A Infinitely adjustable Motor Crank Arm
Dependent on wiring (normally closed)

Building Automation
50017460-001 24/120/230 Vac Internal Transformers for Series 2
Stroke: Adjustable; 90 to 160 degrees
Motors
Deadweight Load on Shaft (Either End): 200 lbs.
50017460-003 120 Vac Internal Transformers for Series 2 Motors
Deadweight Load (Combined on both Shafts): 300 lbs.
4074ERU Weatherproofing kit. Protects motor from driving rain when
Ambient Temperature Range: -40 F to +150 F (-40 C to +60 C)
mounted in any position
Weight: 7.5 lb
Comments: Non-linear feedback, for slaving applications only

Torque/Force Timing (sec)


Internal
Nominal Spring Return Electrical Auxiliary
Product Number (lb-in., lb) (Nm, N) Voltage Timing (sec) Timing (sec) Connections Switch Includes

Components
Commercial
M6284A1055-S 150 lb-in. 17 Nm 120V 30-60 sec — Quick-connect 0 Transformer
terminals
M6284A1071-S 150 lb-in. 17 Nm 120V 30-60 sec — Screw terminals 0 Transformer
* M6284D1000-S 150 lb-in. 17 Nm 24V 30-60 sec — Quick-connect 0 Slave with Series 90
terminals Motors
* M6284D1026-S 150 lb-in. 17 Nm 24V 30-60 sec 60 sec. Quick-connect 0 220741A Screw
Pneumatic Controls

terminals Terminal Adapter


* M6284D4004-S 150 lb-in. 17 Nm 24V 30-60 sec — Quick-connect 0 —
terminals
M6284F1013-S 150 lb-in. 17 Nm 24V 30-60 sec — Quick-connect 2 —
terminals
* M6294D1008-S 300 lb-in. 34 Nm 24V 120-240 sec — Quick-connect 0 —
terminals
* TRADELINE models • SUPER TRADELINE models
Industrial Combustion
Controls

70-6910 453
Modutrol IV™ Motors
M6285 Floating Modutrol IV™ Series 2 Motors,
for Slaving Applications only
provides indication of the motor shaft position and can be used for
slaving Series 90 motors or rebalancing an external control circuit.
• Integral junction box provides NEMA 3 weather protection if motor is
mounted in the upright position.
• Integral spring return returns motor to normal position in the event of
power failure.
• Motor and circuitry operate from 24 Vac.
• Quick-connect terminals are standard--screw terminal adapter is
available.
• Adapter bracket for matching shaft height of older motors is
available.
• Motors have field adjustable stroke (90 to 160 degrees).
• Integral auxiliary switches are available factory mounted, or can be
field added.
• Spring return motors can operate valve linkages from power end or
auxiliary end shafts for normally closed or normally open valve
applications.
• All models have dual shafts (slotted and tapped on both ends).
• All models have auxiliary switch cams.
Series 62 Modutrol IV™ Motors are spring return floating control • Fixed torque throughout the entire voltage range.
motors used with controllers that provide a switched spdt or • Motors are designed for either normally open or normally closed
floating output to operate dampers or valves. These motors also valves and dampers.
have an internal electrically isolated feedback potentiometer that • Include electrically isolated feedback potentiometer that provides
shaft position indication.
Dimensions Diagram: See page 452

Application Type: Electric Comments: Non-linear feedback, for slaving applications only
Fail Safe Mode: Spring Return Approvals:
Control Signal: Floating CE: EN55011 (Emission) EN50082-2 (Immunity) 73/23/EEC (LVD)
Feedback: Yes Underwriters Laboratories, Inc. Listed: File No. E4436, Guide No.
Frequency: 60 Hz; 50 Hz XAPX for USA and Canada
External Auxiliary Switches Available: Yes
Auxiliary Switch Ratings AFL - 120 Vac: 7.2A Accessories:
Auxiliary Switch Ratings ALR - 120 Vac: 43.2A Q7230A1005 Interface module, provides adjustable zero & span,
Auxiliary Switch Ratings AFL - 240 Vac: 3.6A voltage or current control
Auxiliary Switch Ratings ALR - 240 Vac: 21.6A 220736A Internal Auxiliary Switch Assembly - 1 Switch
Electrical Connections: Quick-connect terminals 220736B Internal Auxiliary Switch Assembly - 2 Switches
Mounting: Foot-mounted 220738A Adapter Bracket. Adjusts shaft height to match Modutrol III
Motor Shafts: Dual-ended shaft motors
Shaft Shape: square 220741A2-62 Screw Terminal Adapter Kit for Series 62 Series Modutrol
Shaft Dimensions: 0.375 in. (10 mm) IV Series 2 motors- Converts quick-connect terminals to screw
Shaft Rotation (upon control signal increase): terminals
Dependent on wiring (normally closed) 221455A Infinitely adjustable Motor Crank Arm
Stroke: Adjustable; 90 to 160 degrees 50017460-001 24/120/230 Vac Internal Transformers for Series 2
Deadweight Load on Shaft (Either End): 200 lbs. Motors
Deadweight Load (Combined on both Shafts): 300 lbs. 50017460-003 120 Vac Internal Transformers for Series 2 Motors
Ambient Temperature Range: -40 F to +150 F (-40 C to +60 C) 4074ERU Weatherproofing kit. Protects motor from driving rain when
Weight: 8.5 lb mounted in any position

Torque/Force
Internal Auxiliary
Product Number (Nm, N) (lb-in., lb) Voltage Nominal Timing (sec) Switch
* M6285A1005-S 6.8 Nm 60 lb-in. 24V 30-60 sec 0
M6285C1001-S 6.8 Nm 60 lb-in. 24V 30-60 sec 2
* TRADELINE models • SUPER TRADELINE models

454 customer.honeywell.com 70-6910


Modutrol IV™ Motors
Modutrol IV™ Motor with Linear 10K feedback

Controls
Home
Series 62 Modutrol IV™ Motors Spring Return and Non-Spring
Return floating control motors used with controllers that provide a
switched spdt or floating output to operate dampers or valves.
These motors also have an internal electrically isolated feedback
potentiometer that provides indication of the motor shaft position.
• Integral junction box provides NEMA 3 weather protection if motor is
mounted in the upright position.

Indoor Air Quality


• Motor and circuitry operate from 24 Vac.
• Quick-connect terminals are standard--screw terminal adapter is
available.
• Adapter bracket for matching shaft height of older motors is
available.
• Motors have field adjustable stroke (90 to 160 degrees).
• Integral auxiliary switches are available factory mounted, or can be
field added.
• All models have dual shafts (slotted and tapped on both ends).

Combustion Controls
• All models have auxiliary switch cams.
• Fixed torque throughout the entire voltage range.

Residential
• Motors are designed for either normally open or normally closed
valves and dampers.
• -F models have an internal electrically isolated feedback
potentiometer that provides indication of the motor shaft position.
Dimensions Diagram: See page 452

Application Type: Electric Approvals:

Hydronic Controls
Control Signal: Floating CE: EN55011 (Emission) EN50082-2 (Immunity) 73/23/EEC (LVD)
Feedback: Yes Underwriters Laboratories, Inc. Listed: File No. E4436, Guide No.
Voltage: 24V XAPX for USA and Canada
Frequency: 60 Hz; 50 Hz
External Auxiliary Switches Available: Yes
Accessories:
Q7230A1005 Interface module, provides adjustable zero & span,
Auxiliary Switch Ratings AFL - 120 Vac: 7.2A
voltage or current control
Auxiliary Switch Ratings ALR - 120 Vac: 43.2A
220736A Internal Auxiliary Switch Assembly - 1 Switch
Auxiliary Switch Ratings AFL - 240 Vac: 3.6A
220736B Internal Auxiliary Switch Assembly - 2 Switches
Auxiliary Switch Ratings ALR - 240 Vac: 21.6A
220738A Adapter Bracket. Adjusts shaft height to match Modutrol III
Mounting: Foot-mounted
motors
Motor Shafts: 2; Dual-ended shaft
220741A2-62 Screw Terminal Adapter Kit for Series 62 Series Modutrol

Controls
Shaft Shape: square

Water
IV Series 2 motors- Converts quick-connect terminals to screw
Shaft Dimensions: 0.375 in. (10 mm)
terminals
Shaft Rotation (upon control signal increase):
221455A Infinitely adjustable Motor Crank Arm
Dependent on wiring (normally closed)
50017460-001 24/120/230 Vac Internal Transformers for Series 2
Stroke: Adjustable; 90 to 160 degrees
Motors
Deadweight Load on Shaft (Either End): 200 lbs.
50017460-003 120 Vac Internal Transformers for Series 2 Motors
Deadweight Load (Combined on both Shafts): 300 lbs.
4074ERU Weatherproofing kit. Protects motor from driving rain when

Building Automation
Ambient Temperature Range: -40 F to +150 F (-40 C to +60 C)
mounted in any position
Weight: 6.5 lb
Comments: Linear 10K feedback

Torque/Force Timing (sec)


Spring Internal
Nominal Return Auxiliary
Product Number Fail Safe Mode (lb-in., lb) (Nm, N) Timing Timing Electrical Connections Switch
M6274F1009-F Non-Spring Return 75 lb-in. 8.5 Nm 15/27 — Screw terminals 2
* M6284D1032-F Non-Spring Return 150 lb-in. 17 Nm 30-60 sec — Quick-connect terminals 0

Components
Commercial
M6284F1078-F Non-Spring Return 150 lb-in. 17 Nm 30/53 — Screw terminals 2
M6285F1001-F Spring Return 60 lb-in. 6.8 Nm 30/53 30 sec. Screw terminals 2
M6294F1009-F Non-Spring Return 300 lb-in. 34 Nm 120/214 — Screw terminals 2
M6294F1017-F Non-Spring Return 300 lb-in. 34 Nm 60/107 — Screw terminals 2
* TRADELINE models • SUPER TRADELINE models
Pneumatic Controls
Industrial Combustion
Controls

70-6910 455
Modutrol IV™ Motors
M7164 Modutrol IV™ Series 2 Motors
Series 71 Modutrol IV™ Motors non-spring return motors used to
control dampers and valves. These motors accept a voltage signal
from an electronic controller to position a damper or valve at any
point between open and closed.
• Integral junction box provides NEMA 3 weather protection if motor is
mounted in the upright position.
• Motor and circuitry operate from 24 Vac.
• Quick-connect terminals are standard--screw terminal adapter is
available.
• Adapter bracket for matching shaft height of older motors is
available.
• Motors have field adjustable stroke (90 to 160 degrees).
• Integral auxiliary switches are available factory mounted, or can be
field added.
• All models have dual shafts (slotted and tapped on both ends).
• All models have auxiliary switch cams.
• Fixed torque throughout the entire voltage range.

Dimensions Diagram: See page 452

Application Type: Electric Approvals:


Fail Safe Mode: Non-Spring Return CE: EN55011 (Emission) EN50082-2 (Immunity) 73/23/EEC (LVD)
Control Signal: Modulating, 10.5-13.5 Vdc Underwriters Laboratories, Inc. Listed: File No. E4436, Guide No.
Feedback: No XAPX for USA and Canada
Frequency: 60 Hz; 50 Hz
External Auxiliary Switches Available: Yes
Accessories:
Q7230A1005 Interface module, provides adjustable zero & span,
Auxiliary Switch Ratings AFL - 120 Vac: 7.2A
voltage or current control
Auxiliary Switch Ratings ALR - 120 Vac: 43.2A
220736A Internal Auxiliary Switch Assembly - 1 Switch
Auxiliary Switch Ratings AFL - 240 Vac: 3.6A
220736B Internal Auxiliary Switch Assembly - 2 Switches
Auxiliary Switch Ratings ALR - 240 Vac: 21.6A
220738A Adapter Bracket. Adjusts shaft height to match Modutrol III
Internal Auxiliary Switch: 0
motors
Electrical Connections: Quick-connect terminals
220741A2-71 Screw Terminal Adapter Kit for Series 71 Modutrol IV
Mounting: Foot-mounted
Series 2 motors- Converts quick-connect terminals to screw terminals
Motor Shafts: Dual-ended shaft
221455A Infinitely adjustable Motor Crank Arm
Shaft Shape: square
50017460-001 24/120/230 Vac Internal Transformers for Series 2
Shaft Dimensions: 0.375 in. (10 mm)
Motors
Deadweight Load on Shaft (Either End): 200 lbs.
50017460-003 120 Vac Internal Transformers for Series 2 Motors
Deadweight Load (Combined on both Shafts): 300 lbs.
4074ERU Weatherproofing kit. Protects motor from driving rain when
Ambient Temperature Range: -40 F to +150 F (-40 C to +60 C)
mounted in any position
Weight: 6.5 lb

Torque/Force Nominal
Timing Shaft Rotation (upon control
Product Number (lb-in., lb) (Nm, N) Voltage (sec) Stroke signal increase) Includes
M7164A1017 60 lb-in. 6.8 Nm 24V 30-60 sec Adjustable; 90 to 160 Clockwise (as viewed from power —
degrees end) (normally closed)
M7164G1030 60 lb-in. 6.8 Nm 120V 30-60 sec Adjustable; 90 to 160 Counter-clockwise (as viewed from Transformer
degrees power end) (normally open)

456 customer.honeywell.com 70-6910


Modutrol IV™ Motors
M7274 4-20 mA V Modutrol IV™ Motors

Controls
Home
The Series 72 Modutrol IV™ Motors spring return and non-spring
return motors are used to control dampers and valves. The motors
accept a current or voltage signal from an electronic controller to
position a damper or valve at any point between open and closed.
• Integral spring return returns motor to normal position in the event of
power failure on spring return models.
• Integral junction box provides NEMA 3 weather protection if motor is

Indoor Air Quality


mounted in the upright position.
• Motor and circuitry operate from 24 Vac.
• Quick-connect terminals are standard--screw terminal adapter is
available.
• Adapter bracket for matching shaft height of older motors is
available.
• Motors have field adjustable stroke (90 to 160 degrees).
• Integral auxiliary switches are available factory mounted, or can be
field added.

Combustion Controls
• Spring return motors can operate valve linkages from power end or
auxiliary end shafts for normally closed or normally open valve

Residential
applications.
• All models have dual shafts (slotted and tapped on both ends).
• All models have auxiliary switch cams.
• Fixed torque throughout the entire voltage range.
• Motors are designed for either normally open or normally closed
valves and dampers.
• Models available with adjustable start (zero) and span.
• Models available with 4 to 20 mA input signal.

Hydronic Controls
• Die-cast aluminum housing.
Dimensions Diagram: See page 452
Application Type: Electric Ambient Temperature Range: -40 F to +150 F (-40 C to +60 C)
Fail Safe Mode: Non-Spring Return Weight: 7 lb
Control Signal: Modulating, 4-20 mA
Approvals:
Feedback: No Underwriters Laboratories, Inc. Listed: File No. E4436, Guide No.
Frequency: 60 Hz; 50 Hz XAPX for USA and Canada
External Auxiliary Switches Available: Yes
Auxiliary Switch Ratings AFL - 120 Vac: 7.2A Accessories:
Auxiliary Switch Ratings ALR - 120 Vac: 43.2A Q7230A1005 Interface module, provides adjustable zero & span,

Controls
Water
Auxiliary Switch Ratings AFL - 240 Vac: 3.6A voltage or current control
Auxiliary Switch Ratings ALR - 240 Vac: 21.6A 220736A Internal Auxiliary Switch Assembly - 1 Switch
Internal Auxiliary Switch: 2 220736B Internal Auxiliary Switch Assembly - 2 Switches
Electrical Connections: Screw terminals 220738A Adapter Bracket. Adjusts shaft height to match Modutrol III
Mounting: Foot-mounted motors
Motor Shafts: Dual-ended shaft 220741A2-72 Screw Terminal Adapter Kit for Series 72 Modutrol IV
Shaft Shape: square Series 2 motors - Converts quick-connect terminals to screw terminals

Building Automation
Shaft Dimensions: 0.375 in. (10 mm) 221455A Infinitely adjustable Motor Crank Arm
Shaft Rotation (upon control signal increase): 50017460-001 24/120/230 Vac Internal Transformers for Series 2
Clockwise (as viewed from power end) (normally closed) Motors
Stroke: Adjustable; 90 to 160 degrees 50017460-003 120 Vac Internal Transformers for Series 2 Motors
Deadweight Load on Shaft (Either End): 200 lbs. 4074ERU Weatherproofing kit. Protects motor from driving rain when
Deadweight Load (Combined on both Shafts): 300 lbs. mounted in any position

Torque/Force
Product Number (lb-in., lb) (Nm, N) Voltage Nominal Timing (sec) Comments

Components
Commercial
M7274Q1009 75 lb-in. 8.5 Nm 24V 15/27 Adjustable zero and span for split range applications

Pneumatic Controls
Industrial Combustion
Controls

70-6910 457
Modutrol IV™ Motors
M7284; M7285; M7286; M7294 Modutrol IV™ Series 2 Motors
• Integral spring return returns motor to normal position in the event of
power failure on spring return models.
• Integral junction box provides NEMA 3 weather protection if motor is
mounted in the upright position.
• Motor and circuitry operate from 24 Vac.
• Quick-connect terminals are standard--screw terminal adapter is
available.
• Adapter bracket for matching shaft height of older motors is
available.
• Motors have field adjustable stroke (90 to 160 degrees).
• Integral auxiliary switches are available factory mounted, or can be
field added.
• Spring return motors can operate valve linkages from power end or
auxiliary end shafts for normally closed or normally open valve
applications.
• All models have dual shafts (slotted and tapped on both ends).
• All models have auxiliary switch cams.
• Fixed torque throughout the entire voltage range.
• Motors are designed for either normally open or normally closed
valves and dampers.
• Models available with adjustable start (zero) and span.
• Models available with 4 to 20 mA input signal.
Series 72 Modutrol IV™ Motors are spring return and non-spring • Models available with 2 to 10 Vdc input signal.
return motors (per motor type) used to control dampers and • Die-cast aluminum housing.
valves. The motors accept a current or voltage signal from an
electronic controller to position a damper or valve at any point
between open and closed.
Dimensions Diagram: See page 452

Application Type: Electric Approvals:


Feedback: No CE: EN55011 (Emission) EN50082-2 (Immunity) 73/23/EEC (LVD)
Frequency: 60 Hz; 50 Hz Underwriters Laboratories, Inc. Listed: File No. E4436, Guide No.
External Auxiliary Switches Available: Yes XAPX for USA and Canada
Auxiliary Switch Ratings AFL - 120 Vac: 7.2A
Auxiliary Switch Ratings ALR - 120 Vac: 43.2A
Accessories:
Q7230A1005 Interface module, provides adjustable zero & span,
Auxiliary Switch Ratings AFL - 240 Vac: 3.6A
voltage or current control
Auxiliary Switch Ratings ALR - 240 Vac: 21.6A
220736A Internal Auxiliary Switch Assembly - 1 Switch
Mounting: Foot-mounted
220736B Internal Auxiliary Switch Assembly - 2 Switches
Motor Shafts: Dual-ended shaft
220738A Adapter Bracket. Adjusts shaft height to match Modutrol III
Shaft Shape: square
motors
Shaft Dimensions: 0.375 in. (10 mm)
220741A2-72 Screw Terminal Adapter Kit for Series 72 Modutrol IV
Deadweight Load on Shaft (Either End): 200 lbs.
Series 2 motors - Converts quick-connect terminals to screw terminals
Deadweight Load (Combined on both Shafts): 300 lbs.
221455A Infinitely adjustable Motor Crank Arm
Ambient Temperature Range: -40 F to +150 F (-40 C to +60 C)
50017460-001 24/120/230 Vac Internal Transformers for Series 2
Weight: 7.5 lb
Motors
50017460-003 120 Vac Internal Transformers for Series 2 Motors
4074ERU Weatherproofing kit. Protects motor from driving rain when
mounted in any position

Torque/Force Shaft
Rotation
Fail Nominal Electrical (upon control Internal
Safe Timing Connec- signal Control Auxiliary
Product Number Mode (lb-in., lb) (Nm, N) Voltage (sec) tions Stroke increase) Signal Switch Includes Comments
M7284A1004 Non- 150 lb-in. 17 Nm 120V 30-60 sec Screw Adjustable; Clockwise (as Modulating, 0 Transformer —
Spring terminals 90 to 160 viewed from 4-20 mA and Screw
Return degrees power end) Terminal
(normally closed) Adapter
M7284A1012 Non- 150 lb-in. 17 Nm 120V 30-60 sec Screw Adjustable; Clockwise (as Modulating, 0 Transformer —
Spring terminals 90 to 160 viewed from 4-20 mA and Screw
Return degrees power end) Terminal
(normally closed) Adapter
M7284A1038 Non- 75 lb-in. 8.5 Nm 120V 15-30 sec Screw Adjustable; Clockwise (as Modulating, 0 Transformer —
Spring terminals 90 to 160 viewed from 4-20 mA and Screw
Return degrees power end) Terminal
(normally closed) Adapter
M7284A1079 Non- 150 lb-in. 17 Nm 24V 30-60 sec Quick- Adjustable; Clockwise (as Modulating, 0 — —
Spring connect 90 to 160 viewed from 2-10 Vdc
Return terminals degrees power end)
(normally closed)
M7284C1000 Non- 150 lb-in. 17 Nm 120V 30-60 sec Screw Adjustable; Clockwise (as Modulating, 2 Transformer —
Spring terminals 90 to 160 viewed from 4-20 mA and Screw
Return degrees power end) Terminal
(normally closed) Adapter

458 customer.honeywell.com 70-6910


Modutrol IV™ Motors

Controls
Torque/Force Shaft

Home
Rotation
Fail Nominal Electrical (upon control Internal
Safe Timing Connec- signal Control Auxiliary
Product Number Mode (lb-in., lb) (Nm, N) Voltage (sec) tions Stroke increase) Signal Switch Includes Comments
M7284C1083 Non- 150 lb-in. 17 Nm 24/120/ 30 sec Screw Fixed; 90 Clockwise (as Modulating, 2 Transformer Enhanced models,
Spring 230V terminals degrees viewed from 4-20 mA additional repositions
Return power end)

Indoor Air Quality


(normally closed)
M7284C1091 Non- 150 lb-in. 17 Nm 24/120/ 60 sec Screw Fixed; 160 Clockwise (as Modulating, 2 Transformer Enhanced models,
Spring 230V terminals degrees viewed from 4-20 mA additional repositions
Return power end)
(normally closed)
M7284Q1009 Non- 150 lb-in. 17 Nm 120V 30-60 sec Screw Adjustable; Clockwise (as Modulating, 2 Transformer Adjustable zero and
Spring terminals 90 to 160 viewed from 4-20 mA and Screw span for split range
Return degrees power end) Terminal applications
(normally closed) Adapter

Combustion Controls
M7284Q1082 Non- 150 lb-in. 17 Nm 24/120/ 30 sec Screw Fixed; 90 Clockwise (as Modulating, 2 Transformer Enhanced models,

Residential
Spring 230V terminals degrees viewed from 4-20 mA additional repositions
Return power end) (160°)
(normally closed) Adjustable zero and
span for split range
applications
M7284Q1090 Non- 150 lb-in. 17 Nm 24/120/ 60 sec Screw Fixed; 160 Clockwise (as Modulating, 2 Transformer Enhanced models,
Spring 230V terminals degrees viewed from 4-20 mA additional repositions
Return power end) (160°)
(normally closed) Adjustable zero and

Hydronic Controls
span for split range
applications
M7284Q1098 Non- 150 lb-in. 17 Nm 24V 30-53 Screw Adjustable; Clockwise (as 2 to 10 Vdc 2 — Enhanced models,
Spring terminals 90 to 160 viewed from additional repositions
Return degrees power end) Adjustable zero and
(normally closed) span for split range
applications
M7284Q1106 Non- 150 lb-in. 17 Nm 24V 30-60 sec Screw Adjustable; Clockwise (as Modulating, 2 — Adjustable zero and
Spring terminals 90 to 160 viewed from 4-20 mA span for split range
Return degrees power end) applications
(normally closed)

Controls
Water
M7285A1003 Spring 60 lb-in. 6.8 Nm 120V 30-60 sec Screw Adjustable; Clockwise (as Modulating, 0 Transformer —
Return terminals 90 to 160 viewed from 4-20 mA and Screw
degrees power end) Terminal
(normally closed) Adapter
M7285A1045 Spring 60 lb-in. 6.8 Nm 24V 30-60 sec Quick- Adjustable; Clockwise (as Modulating, 0 — —
Return connect 90 to 160 viewed from 2-10 Vdc
terminals degrees power end)

Building Automation
(normally closed)
M7285C1009 Spring 60 lb-in. 6.8 Nm 120V 30-60 sec Screw Adjustable; Clockwise (as Modulating, 2 Transformer —
Return terminals 90 to 160 viewed from 4-20 mA and Screw
degrees power end) Terminal
(normally closed) Adapter
M7285Q1008 Spring 60 lb-in. 6.8 Nm 120V 30-60 sec Screw Adjustable; Clockwise (as Modulating, 2 Transformer Adjustable zero and
Return terminals 90 to 160 viewed from 4-20 mA and Screw span for split range
degrees power end) Terminal applications
(normally closed) Adapter
M7285Q1024 Spring 60 lb-in. 6.8 Nm 24 V 30/53 Screw Adjustable; Clockwise (as Modulating, 2 Screw —

Components
Return terminals 90 to 160 viewed from 4-20 mA Terminal

Commercial
degrees power end) Adapter
(normally closed)
M7285Q1032 Spring 60 lb-in. 6.8 Nm 24 V 30/53 Screw Adjustable; Clockwise (as Modulating, 2 Screw —
Return terminals 90 to 160 viewed from 2-10 Vdc Terminal
degrees power end) Adapter
(normally closed)
M7286G1009 Spring 60 lb-in. 6.8 Nm 24V 30-60 sec Quick- Adjustable; Counter- Modulating, 0 — —
Pneumatic Controls

Return connect 90 to 160 clockwise (as 2-10 Vdc


terminals degrees viewed from
power end)
(normally open)
M7294A1010 Non- 300 lb-in. 34 Nm 24V 60-120 Quick- Adjustable; Clockwise (as Modulating, 0 — —
Spring sec connect 90 to 160 viewed from 2-10 Vdc
Return terminals degrees power end)
(normally closed)
Industrial Combustion
Controls

70-6910 459
Modutrol IV™ Motors
Torque/Force Shaft
Rotation
Fail Nominal Electrical (upon control Internal
Safe Timing Connec- signal Control Auxiliary
Product Number Mode (lb-in., lb) (Nm, N) Voltage (sec) tions Stroke increase) Signal Switch Includes Comments
M7294Q1007 Non- 300 lb-in. 34 Nm 120V 60-120 Screw Adjustable; Clockwise (as Modulating, 2 Transformer Adjustable zero and
Spring sec terminals 90 to 160 viewed from 4-20 mA and Screw span for split range
Return degrees power end) Terminal applications
(normally closed) Adapter
M7294Q1015 Non- 300 lb-in. 34 Nm 24V 60/107 Screw Adjustable; Clockwise (as Modulating, 2 Screw Adjustable zero and
Spring terminals 90 to 160 viewed from 4-20 mA Terminal span for split range
Return degrees power end) Adapter applications
(normally closed)

M7685 Modutrol IV™ Series 2 Motor


Proportional, spring-return motors for use with Honeywell W7080
panel 14-17 Vdc output; with minimum position adjustment.
• Integral spring return returns motor to normal position in the event of
power failure.
• Integral junction box provides NEMA 3 weather protection.
• Motor and circuitry operate from 24 Vac.
• Quick-connect terminals are standard.
• Adapter bracket for matching shaft height of older motors is
available.
• Motors have field adjustable stroke (90 deg. to 160 deg.).
• Integral auxiliary switches are available factory mounted, or can be
field added.
• Spring return motors can operate valve linkages from power end or
auxiliary end shafts for normally closed or normally open valve
applications.
• All models have dual shafts (slotted and tapped on both ends).
• All models have auxiliary switch cams.
• Fixed torque throughout the entire voltage range.
Dimensions Diagram: See page 452
Application Type: Electric Deadweight Load (Combined on both Shafts): 300 lbs.
Fail Safe Mode: Spring Return Ambient Temperature Range: -40 F to +150 F (-40 C to +60 C)
Control Signal: Modulating, 14-17 Vdc Weight: 8.5 lb
Feedback: No
Approvals:
Frequency: 60 Hz; 50 Hz Underwriters Laboratories, Inc. Listed: File No. E4436, Guide No.
External Auxiliary Switches Available: Yes XAPX for USA and Canada
Auxiliary Switch Ratings AFL - 120 Vac: 7.2A
Auxiliary Switch Ratings ALR - 120 Vac: 43.2A Accessories:
Auxiliary Switch Ratings AFL - 240 Vac: 3.6A Q7230A1005 Interface module, provides adjustable zero & span,
Auxiliary Switch Ratings ALR - 240 Vac: 21.6A voltage or current control
Internal Auxiliary Switch: 0 220736A Internal Auxiliary Switch Assembly - 1 Switch
Electrical Connections: Quick-connect terminals 220736B Internal Auxiliary Switch Assembly - 2 Switches
Mounting: Foot-mounted 220738A Adapter Bracket. Adjusts shaft height to match Modutrol III
Motor Shafts: Dual-ended shaft motors
Shaft Shape: square 221455A Infinitely adjustable Motor Crank Arm
Shaft Dimensions: 0.375 in. (10 mm) 50017460-001 24/120/230 Vac Internal Transformers for Series 2
Shaft Rotation (upon control signal increase): Motors
Clockwise (as viewed from power end) (normally closed) 50017460-003 120 Vac Internal Transformers for Series 2 Motors
Stroke: Adjustable; 90 to 160 degrees 4074ERU Weatherproofing kit. Protects motor from driving rain when
Deadweight Load on Shaft (Either End): 200 lbs. mounted in any position

Torque/Force
Product Number (lb-in., lb) (Nm, N) Voltage Nominal Timing (sec) Includes
M7685A1025 60 lb-in. 6.8 Nm 24V 30-60 sec Minimum Position Potentiometer

460 customer.honeywell.com 70-6910


Modutrol IV™ Motors
M9182 Modutrol IV™ Series 3 Motors

Controls
Home
• Integral junction box provides NEMA 3 weather protection if motor is
mounted in the upright position.
• Integral spring return returns motor to normal position in the event of
power failure.
• Motor and circuitry operate from 24 Vac.
• Quick-connect terminals are standard; screw terminal adapter is
available.

Indoor Air Quality


• Adapter bracket for matching shaft height of older motors is
available.
• Motors have field adjustable stroke (90 to 160 degrees).
• Integral auxiliary switches are available factory mounted, or can be
field added.
• Spring return motors can operate valve linkages from power end or
auxiliary end shafts for normally closed or normally open valve
applications.
• All models have dual shafts (slotted and tapped on both ends).

Combustion Controls
• All models have auxiliary switch cams.
• Fixed torque throughout the entire voltage range.

Residential
Series 90 Modutrol® IV Motors spring return modulating
proportional control motors used with controllers that provide a
Series 90 output to operate dampers or valves.
Dimensions Diagram: See page 452

Application Type: Electric Weight: 8.5 lb


Fail Safe Mode: Spring Return
Approvals:
Control Signal: Proportional, 135 ohm

Hydronic Controls
Underwriters Laboratories, Inc. Listed: File No. E4436, Guide No.
Feedback: No XAPX for USA and Canada
Frequency: 60 Hz; 50 Hz
External Auxiliary Switches Available: Yes Accessories:
Auxiliary Switch Ratings AFL - 120 Vac: 7.2A Q7230A1005 Interface module, provides adjustable zero & span,
Auxiliary Switch Ratings ALR - 120 Vac: 43.2A voltage or current control
Auxiliary Switch Ratings AFL - 240 Vac: 3.6A 220736A Internal Auxiliary Switch Assembly - 1 Switch
Auxiliary Switch Ratings ALR - 240 Vac: 21.6A 220736B Internal Auxiliary Switch Assembly - 2 Switches
Internal Auxiliary Switch: 0 220738A Adapter Bracket. Adjusts shaft height to match Modutrol III
Electrical Connections: Quick-connect terminals motors
Mounting: Foot-mounted 220741A2-90 Screw Terminal Adapter Kit for Series 90 Modutrol IV
Motor Shafts: Dual-ended shaft Series 2and Series 3 motors - Converts quick-connect terminals to

Controls
Water
Shaft Shape: square screw terminals
Shaft Dimensions: 0.375 in. (10 mm) 221455A Infinitely adjustable Motor Crank Arm
Shaft Rotation (upon control signal increase): 50017460-001 24/120/230 Vac Internal Transformers for Series 2
Clockwise (as viewed from power end) (normally closed) Motors
Stroke: Adjustable; 90 to 160 degrees 50017460-003 120 Vac Internal Transformers for Series 2 Motors
Deadweight Load on Shaft (Either End): 200 lbs. 4074ERU Weatherproofing kit. Protects motor from driving rain when
Deadweight Load (Combined on both Shafts): 300 lbs. mounted in any position

Building Automation
Ambient Temperature Range: -40 F to +150 F (-40 C to +60 C)

Torque/Force
Product Number (lb-in., lb) (Nm, N) Voltage Nominal Timing (sec)
M9182A1011 60 lb-in. 6.8 Nm 24V 30-60 sec

Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 461
Modutrol IV™ Motors
M9164; M9174; M9184; M9194 Modutrol IV™ Series 3 Motors
Series 90 Modutrol® IV Motors non-spring return modulating
proportional control motors used with controllers that provide a
Series 90 output to operate dampers or valves.
• Integral junction box provides NEMA 3 weather protection if motor is
mounted in the upright position.
• Motor and circuitry operate from 24 Vac.
• Quick-connect terminals are standard; screw terminal adapter is
available.
• Adapter bracket for matching shaft height of older motors is
available.
• Motors have field adjustable stroke (90 to 160 degrees).
• Integral auxiliary switches are available factory mounted, or can be
field added.
• All models have dual shafts (slotted and tapped on both ends).
• All models have auxiliary switch cams.
• Fixed torque throughout the entire voltage range.

Dimensions Diagram: See page 452

Application Type: Electric Approvals:


Fail Safe Mode: Non-Spring Return CE: EN55011 (Emission) EN50082-2 (Immunity) 73/23/EEC (LVD)
Control Signal: Proportional, 135 ohm Underwriters Laboratories, Inc. Listed: File No. E4436, Guide No.
Feedback: No XAPX for USA and Canada
Frequency: 60 Hz; 50 Hz
External Auxiliary Switches Available: Yes
Accessories:
Q7230A1005 Interface module, provides adjustable zero & span,
Auxiliary Switch Ratings AFL - 120 Vac: 7.2A
voltage or current control
Auxiliary Switch Ratings ALR - 120 Vac: 43.2A
220736A Internal Auxiliary Switch Assembly - 1 Switch
Auxiliary Switch Ratings AFL - 240 Vac: 3.6A
220736B Internal Auxiliary Switch Assembly - 2 Switches
Auxiliary Switch Ratings ALR - 240 Vac: 21.6A
220738A Adapter Bracket. Adjusts shaft height to match Modutrol III
Mounting: Foot-mounted
motors
Motor Shafts: Dual-ended shaft
220741A2-90 Screw Terminal Adapter Kit for Series 90 Modutrol IV
Shaft Shape: square
Series 2and Series 3 motors - Converts quick-connect terminals to
Shaft Dimensions: 0.375 in. (10 mm)
screw terminals
Shaft Rotation (upon control signal increase):
221455A Infinitely adjustable Motor Crank Arm
Clockwise (as viewed from power end) (normally closed)
50017460-001 24/120/230 Vac Internal Transformers for Series 2
Stroke: Adjustable; 90 to 160 degrees
Motors
Deadweight Load on Shaft (Either End): 200 lbs.
50017460-003 120 Vac Internal Transformers for Series 2 Motors
Deadweight Load (Combined on both Shafts): 300 lbs.
4074ERU Weatherproofing kit. Protects motor from driving rain when
Ambient Temperature Range: -40 F to +150 F (-40 C to +60 C)
mounted in any position
Weight: 7.5 lb

Torque/Force Internal
Nominal Auxiliary
Product Number (lb-in., lb) (Nm, N) Voltage Timing (sec) Electrical Connections Switch Includes
M9164A1005 60 lb-in. 4 Nm 120V 30-60 sec Quick-connect terminals 0 Transformer
M9164A1013 60 lb-in. 4 Nm 24/120/230V 30-60 sec Quick-connect terminals 0 Transformer
M9164A1070 60 lb-in. 4 Nm 24V 30-60 sec Quick-connect terminals 0 —
M9164C1001 60 lb-in. 4 Nm 24V 30-60 sec Quick-connect terminals 2 —
M9164C1068 60 lb-in. 4 Nm 120V 30-60 sec Quick-connect terminals 2 Transformer
* M9164D1009 60 lb-in. 4 Nm 24V 30-60 sec Quick-connect terminals 0 —
M9174B1027 75 lb-in. 8.5 Nm 120V 30-60 sec Quick-connect terminals 1 Transformer
M9174C1025 75 lb-in. 8.5 Nm 120V 30-60 sec Quick-connect terminals 2 Transformer
M9174C1033 75 lb-in. 8.5 Nm 120V 30-60 sec Quick-connect terminals 2 Transformer
* M9174D1007 75 lb-in. 8.5 Nm 24V 30-60 sec Quick-connect terminals 0 —
M9174F1001 75 lb-in. 8.5 Nm 24 V 30/53 Screw terminals 2 —
M9184A1019 150 lb-in. 17 Nm 24V 30-60 sec Quick-connect terminals 0 —
M9184C1031 150 lb-in. 17 Nm 24V 30-60 sec Quick-connect terminals 2 —
M9184D1005 75 lb-in. 8.5 Nm 24V 15-30 sec Quick-connect terminals 0 —
* M9184D1021 150 lb-in. 17 Nm 24V 30-60 sec Quick-connect terminals 0 —
M9184F1034 150 lb-in. 17 Nm 24V 30-60 sec Quick-connect terminals 2 —
* M9194D1003 300 lb-in. 34 Nm 24V 120-240 sec Quick-connect terminals 0 —
M9194E1000 300 lb-in. 34 Nm 24V 120-240 sec Quick-connect terminals 1 —
* TRADELINE models • SUPER TRADELINE models

462 customer.honeywell.com 70-6910


Modutrol IV™ Motors
M9175; M9185 Modutrol IV™ Series 3 Motors

Controls
Home
Series 90 Modutrol® Motors are spring return modulating
proportional control motors used with controllers that provide a
Series 90 output to operate dampers or valves.
• Integral junction box provides NEMA 3 weather protection if motor is
mounted in the upright position.
• Integral spring return returns motor to normal position in the event of
power failure.

Indoor Air Quality


• Motor and circuitry operate from 24 Vac.
• Quick-connect terminals are standard; screw terminal adapter is
available.
• Adapter bracket for matching shaft height of older motors is
available.
• Motors have field adjustable stroke (90 to 160 degrees).
• Integral auxiliary switches are available factory mounted, or can be
field added.
• Spring return motors can operate valve linkages from power end or

Combustion Controls
normally open valve applications.
• All models have dual shafts (slotted and tapped on both ends).

Residential
• All models have auxiliary switch cams.
• Fixed torque throughout the entire voltage range.
Dimensions Diagram: See page 452

Application Type: Electric Approvals:


Fail Safe Mode: Spring Return CE: EN55011 (Emission) EN50082-2 (Immunity) 73/23/EEC (LVD)
Control Signal: Proportional, 135 ohm Underwriters Laboratories, Inc. Listed: File No. E4436, Guide No.

Hydronic Controls
Feedback: No XAPX for USA and Canada
Frequency: 60 Hz; 50 Hz
External Auxiliary Switches Available: Yes
Accessories:
Q7230A1005 Interface module, provides adjustable zero & span,
Auxiliary Switch Ratings AFL - 120 Vac: 7.2A
voltage or current control
Auxiliary Switch Ratings ALR - 120 Vac: 43.2A
220736A Internal Auxiliary Switch Assembly - 1 Switch
Auxiliary Switch Ratings AFL - 240 Vac: 3.6A
220736B Internal Auxiliary Switch Assembly - 2 Switches
Auxiliary Switch Ratings ALR - 240 Vac: 21.6A
220738A Adapter Bracket. Adjusts shaft height to match Modutrol III
Mounting: Foot-mounted
motors
Motor Shafts: Dual-ended shaft
220741A2-90 Screw Terminal Adapter Kit for Series 90 Modutrol IV
Shaft Shape: square
Series 2and Series 3 motors - Converts quick-connect terminals to
Shaft Dimensions: 0.375 in. (10 mm)
screw terminals

Controls
Shaft Rotation (upon control signal increase):

Water
221455A Infinitely adjustable Motor Crank Arm
Clockwise (as viewed from power end) (normally closed)
50017460-001 24/120/230 Vac Internal Transformers for Series 2
Stroke: Adjustable; 90 to 160 degrees
Motors
Deadweight Load on Shaft (Either End): 200 lbs.
50017460-003 120 Vac Internal Transformers for Series 2 Motors
Deadweight Load (Combined on both Shafts): 300 lbs.
4074ERU Weatherproofing kit. Protects motor from driving rain when
Ambient Temperature Range: -40 F to +150 F (-40 C to +60 C)
mounted in any position
Weight: 8.5 lb

Building Automation
Torque/Force
Product Number (lb-in., lb) (Nm, N) Voltage Nominal Timing (sec) Electrical Connections Internal Auxiliary Switch
M9185A1018 60 lb-in. 6.8 Nm 24V 30-60 sec Quick-connect terminals 0
M9185C1006 60 lb-in. 6.8 Nm 24V 30-60 sec Quick-connect terminals 2
* M9185D1004 60 lb-in. 6.8 Nm 24V 30-60 sec Quick-connect terminals 0
M9185E1019 60 lb-in. 6.8 Nm 24V 30-60 sec Quick-connect terminals 1
M9185F1002 60 lb-in. 6.8 Nm 24V 30/53 Screw terminals 2

Components
Commercial
* TRADELINE models • SUPER TRADELINE models

Pneumatic Controls
Industrial Combustion
Controls

70-6910 463
Modutrol IV™ Motors
Foot Mounted Motor Accessories
Product Number Description Used With
203709D2 Screw Terminal Adapter for Series 70 Mod IV Motors Series 2 and Series 3 Modutrol
With Zero and Span Adjustment IV™ motors

220738A Adapter Bracket. Adjusts shaft height to match Modutrol Mod IV Actuator to match shaft
III motors height of Mod III Actuator

220738 M11550

220741A2-61 Screw Terminal Adapter Kit for Series 61 Modutrol IV Series 61 Mod IV Motor
Series 2 motors- Converts quick-connect terminals to
screw terminals
220741A2-62 Screw Terminal Adapter Kit for Series 62 Series Series 62 Mod IV Motor
Modutrol IV Series 2 motors- Converts quick-connect
terminals to screw terminals
220741A2-71 Screw Terminal Adapter Kit for Series 71 Modutrol IV Series 71 Mod IV Motor
Series 2 motors- Converts quick-connect terminals to
screw terminals
220741A2-72 Screw Terminal Adapter Kit for Series 72 Modutrol IV Series 72 Mod IV Motor
Series 2 motors - Converts quick-connect terminals to
screw terminals
220741A2-90 Screw Terminal Adapter Kit for Series 90 Modutrol IV Series 90 Mod IV Motor
Series 2and Series 3 motors - Converts quick-connect
terminals to screw terminals
220741A2-TP Screw Terminal Adapter Kit for 2 position Modutrol IV Two Position for use with M4XXX
Series 2 motors - Converts quick-connect terminals to and M8XXX Mod IV Motors
screw terminals
221455A Infinitely adjustable Motor Crank Arm Modutrol IV Motors

221508A2 Resistor Board Assembly for Series 2 Modutrol IV Series 2 Modutrol IV Motors
Motors

4074ERU Weatherproofing kit. Protects motor from driving rain Fits all Modutrol IV motors.
when mounted in any position

464 customer.honeywell.com 70-6910


Modutrol IV™ Motors

Controls
Product Number Description Used With

Home
7617DM Coupling- Must be used with ES650117 explosion-proof ES650117
housing

Indoor Air Quality


M11515
7617DM
ES-650-117 Explosion-Proof Housing encloses motor for use in Modutrol IV Motors, not for use
explosive atmospheres. To order contact: EGS with Q5001 (or any other valve
Enclosures, (281) 774-3763; or write to: EGS linkages)

Combustion Controls
Enclosures in Houston, TX Karen Barfield 281-774-3763
[email protected] Part number ES-650-117

Residential
Hydronic Controls
ES-650-117 M11534

220736 Internal Auxiliary Switch Kits


Application Type: Internal Auxiliary Switch Kits
Control Signal: SPDT, On/Off switch
Auxiliary Switch Ratings AFL - 120 Vac: 7.2A
Auxiliary Switch Ratings ALR - 120 Vac: 43.2A
Auxiliary Switch Ratings AFL - 240 Vac: 3.6A
Auxiliary Switch Ratings ALR - 240 Vac: 21.6A

Controls
Water
Electrical Connections: 15 in (381 mm) Lead Wires
Ambient Temperature Range: 0 F to 131 F (-18 C to +55 C)
Weight: 0.3 lb

Product Number Includes Used With

Building Automation
220736A One Micro Switch V3 precision switch, which is actuated by adjustable cams inside the motor. TRADELINE Modutrol IV Motors
220736B Two Micro Switch V3 precision switches, which are actuated by adjustable cams inside the motor. TRADELINE Modutrol IV Motors

Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 465
Modutrol IV™ Motors
50017460 Internal Transformers for Series 2 Motors
Application Type: Internal Transformer
Control Signal: SPST, On/Off switch
Frequency: 60 Hz; 50 Hz
Mounting: Internal mount to Modutrol IV™ Motors
Ambient Temperature Range: 0 F to 131 F (-18 C to +55 C)

Product Number Voltage Includes Used With


50017460-001 24/120/230 Vac Transformer, screws, instructions for mounting internally in Modutrol IV Series 2 motors Series 2 Modutrol IV Motors
50017460-003 120 Vac Transformer, screws, instructions for mounting internally in Modutrol IV Series 2 motors Series 2 Modutrol IV Motors

198162 Internal Transformer for Series 1 Motors


Application Type: Internal Transformer
Control Signal: SPST, On/Off switch
Ambient Temperature Range: 0 F to 131 F (-18 C to +55 C)

Product Number Voltage Includes Comments


198162AA 120/208/240 Vac at 50 or 60 Hz Transformer, screws, instructions for mounting internally in For Mod IV Series 2 actuator, use
Modutrol IV Series 1 motors 50017460-001
198162EA 120 Vac at 50 or 60 Hz Transformer, screws, instructions for mounting internally in For Mod IV Series 2 actuator, use
Modutrol IV Series 1 motors 50017460-003
198162GA 220 Vac at 50 or 60 Hz Transformer, screws, instructions for mounting internally in For Mod IV Series 2 actuator, use
Modutrol IV Series 1 motors 50017460-001
198162JA 24 Vac (for electrical isolation) Transformer, screws, instructions for mounting internally in For Mod IV Series 2 actuator, use
Modutrol IV Series 1 motors 50017460-001

Q181 Auxiliary Potentiometer for Modutrol Motors


Controls from one to four Modutrol (Series 90) motors from one
master motor.
• Compatible with Modutrol III and Modutrol IV™ motors.
• Mounts on master motor and operates controlled motors in unison or
in sequence.
• Controls motors with mechanical balance relay and solid state drive
circuit.
• Use with 24V motors.

Application Type: Electro-mechanical Weight: 1.38 lb


Dimensions, Approximate: 3 3/16 in. high x 3 1/4 in. wide x 3 3/8 in.
Approvals:
deep (81 mm high x 83 mm wide x 86 mm deep) CE: Report: GV97-011
Mounting: External mount to Modutrol IV™ Motors

Product Number Electrical Connections Control Signal Includes Comments Used With
Q181A1007 Screw terminals SPST, On/Off switch Cover For controlling one modutrol motor Series 90
Q181A1015 Screw terminals SPST, On/Off switch Cover For controlling two modutrol motors Series 90
Q181A1064 Screw terminals SPST, On/Off switch — For controlling up to three modutrol motors Series 90
Q181A1072 Screw terminals SPST, On/Off switch — For controlling up to four modutrol motors Series 90

466 customer.honeywell.com 70-6910


Modutrol IV™ Motors
Q209 Manual Potentiometer for Modutrol Motors

Controls
Home
Used to limit minimum position of a proportioning Modutrol motor.
• Mount directly in motor.
• All wiring is accomplished within motor wiring compartment.
• Color-coded leadwires.

Application Type: Electro-mechanical


Dimensions, Approximate: 3 1/4 in. high x 3 3/8 in. wide x 3 7/8 in.

Indoor Air Quality


deep (83 mm high x 86 mm wide x 98 mm deep)
Control Signal: SPST, On/Off switch
Mounting: Internal mount to Modutrol IV™ Motors
Weight: 0.2 lb
Approvals:
CE: Report: GV97-011

Combustion Controls
Product Number Electrical Connections Includes Used With

Residential
Q209A1022 Screw terminals 150 ohm Potentiometer, leadwires and bracket M9184; M9185; M6284;
M6285
Q209A1030 Screw terminals 300 ohm Potentiometer, leadwires and bracket M9184; M9185; M6284;
M6285
Q209E1002 Quick-connect terminals with lead wires 150 ohm Potentiometer, factory mounted on a wring cover box —
Q209E1010 Quick-connect terminals with lead wires 300 Ohm Potentiometer, Factory Mounted on a wiring cover box —

Hydronic Controls
Q607 Auxiliary Switches for Modutrol Motors
For control of auxiliary equipment as a function of motor shaft
position.
• Compatible with Modutrol III and Modutrol IV™ motors. (Requires
220738A adapter bracket for use with Modutrol IV™ motors).
• Micro Switch precision switches, adjustable.
• Indicate motor position by use of a scale plate anchored to a
common shaft, which allows Q607 to be adjusted for operational
sequence before mounting.

Controls
• Adjustable plate allows universal mounting on either end of motor.

Water
• Wrap-around cover for easy access to switch adjustments and
wiring.
• Maintenance-free protection of the switches and cams.

Application Type: Electro-mechanical Electrical Connections: Screw terminals

Building Automation
Dimensions, Approximate: 6 7/16 in. high x 5 3/16 in. wide x 2 1/8 in. Mounting: Cover or gear end
deep (164 mm high x 132 mm wide x 54 mm deep) Weight: 2.5 lb
Control Signal: SPDT, On/Off switch
Approvals:
Auxiliary Switch Ratings AFL - 120 Vac: 9.8A Canadian Standards Association: Certified: File No. LR1620
Auxiliary Switch Ratings ALR - 120 Vac: 58.8A Underwriters Laboratories, Inc. Listed File: E4436, Guide: XAPX2
Auxiliary Switch Ratings AFL - 240 Vac: 4.90A
Auxiliary Switch Ratings ALR - 240 Vac: 29.4A

Electrical Internal Auxiliary


Product Number Connections Switch Includes Comments

Components
Commercial
Q607A1050 Screw terminals 1 Revised mounting bracket Post 1969 Honeywell Modutrol
Motors
* Q607A1076 Screw terminals 1 With adapter for cover end spring return motor and Post 1969 Honeywell Modutrol
revised mounting bracket Motors
Q607B1067 Screw terminals 2 Revised mounting bracket Pre/Post 1969 Honeywell
Modutrol Motors
* Q607B1083 Screw terminals 2 With adapter for cover end spring return motor and —
Pneumatic Controls

revised mounting bracket


Q607C1009 Terminal Board 1 Special terminal panel and metric grounding screws —
Q607D1008 Terminal Board 2 Special terminal panel and metric grounding screws —
* TRADELINE models • SUPER TRADELINE models
Industrial Combustion
Controls

70-6910 467
Modutrol IV™ Motors
S443 Manual Potentiometer for Modutrol Motors
Used for remote manual control of proportioning (Series 90)
motors and relays.
• Compatible with Modutrol III and Modutrol IV™ motors.
• Select automatic or manual control with DPST toggle switch.
• Suitable for Series 90, M7685; and M7285 motors controlled by 135
ohm inputs.
• Surface mounted, with conduit outlet on each side of case. Screw
terminals.
• Scale marked OPEN-CLOSE.

Internal schematic of S443A Application Type: Electric


Dimensions, Approximate: *
TERMINALBLOCK *Fits inside wiring junction box of Modutrol IV™ Motor
R W B
Including Knob 3 3/4 in. high, 3 3/8 in. wide, 3 1/4 in. deep.
(95 mm high, 86 mm wide, 83 mm deep.)
R W B
Control Signal: SPST, On/Off switch
Mounting: Surfaced mounted with conduit knock-outs
Ambient Temperature Range: -40 F to +150 F (-40 C to +60 C)
MANUAL

POTENTIOMETER
Weight: 1.3 lb
AUTO

DPDT SWITCH M17510

Electrical
Product Number Connections Comments Used With
S443A1007 Screw terminals 2 position manual switch M9164; M9484; M9184; M9185 and motors replaced by these motors

468 customer.honeywell.com 70-6910


Modutrol IV™ Motors
Q7130; Q7230; Q7330 Interface Modules for Series 90 Modutrol IV™

Controls
Home
Motors
For converting Series 90 Modutrol IV™ motors to Series 70
(electronic) control.
• Mounts and works inside wiring box of any series 90 Modutrol IV™
Motor.
• Protected from weather by motor's NEMA 3 wiring box.

Indoor Air Quality


• Mates to motor's quick-connect terminals and provides screw
terminals for control wiring connections.
• Features solid-state circuitry with surface mount components.
• Cover holds module in place, screws not required.
• Includes (except Q7330A) reversing switch to allow replacement of
electrically normally open or electrically normally closed motors.

Application Type: Electric


Dimensions, Approximate: Fits inside wiring junction box of Modutrol

Combustion Controls
IV™ Motor
Frequency: 60 Hz; 50 Hz

Residential
Electrical Connections: Terminal Board
Mounting: Mounts to quick-connects inside Mod Motor
Ambient Temperature Range: -40 F to +150 F (-40 C to +60 C)
Weight: 0.3 lb

Electrical

Hydronic Controls
Product Number Connections Control Signal Used With
Q7130A1006 Terminal Board Provides selectable voltage ranges: 4 to 7, 6 to 9, or 10.5 to 13.5 Vdc. Adapts Series 90 for conversion to
M91XX to function as M71XX model Series 70
Q7230A1005 Terminal Board Provides adjustable zero & span, voltage or current control (includes 2-10 Vdc or 4- Series 90 for conversion to
20 mA). Adapts M91XX to function as M72XX model. Series 70
Q7330A1004 Terminal Board Provides interface to W936 Control. Adapts M91XX to function as M73XX model. Series 90 for conversion to
Series 70

Interface Module Cross Reference and Usage Chart

Controls
Water
.
Product Number Application Replaces Replaces Use With
Q7130A1006 Provides selectable voltage ranges: 4 to 7, 6 to 9 or 10.5 M744D1011, M744D1003 M7184A1005 M9184D1021
to 13.5 Vdc. Adapts M91XX Modutrol IV™ motor to
M745P1007 M7185A1004 M9185D1004
function as M71XX model for M734H,J; M744D; M745G,P
replacements.

Building Automation
Q7230A1005 Provides adjustable zero and span, voltage or current M744S1005 M7284A1004 M9184D1021
control (includes 4 to 20 mA and 2 to 10 Vdc). Adapts
M744S1013 M7284A1012
M91XX Modutrol IV™ motors to function as M72XX model
for M744S,T,Y; M745S,T,Y replacements. M744T1004 M7284C1000
M744T1012 M7284C1018
M744Y1009 M7284Q1009
M744Y1017 M7284Q1017
M745S1002 M7285A1003 M9185D1004

Components
Commercial
M745S1010 M7285A1011
M745T1001 M7285C1009
M745T1019 M7285C1017
M745Y1006 M7285Q1008
M745Y1014 M7285Q1016
Pneumatic Controls

Q7330A1004 Provides interface to W936 Control. Adapts M91XX M744A1006 M7384A1003 M9184D1021
Modutrol IV motor to function as M73XX model for M734D;
M744A1014 M7384A1011
M744A; M745A replacements.
M745A1003 M7385A1002 M9185D1004
M745A1011 M7385A1010
Industrial Combustion
Controls

70-6910 469
Kit Mounted Motors
M436; M836 Damper Motors
Spring return motors for two-position back draft, outdoor air
changeover, zone, or minimum position damper control.
• Operate outdoor air dampers for combustion or makeup air in
residential and light commercial applications.
• Operate changeover dampers for heating and cooling systems.
• Operate minimum position dampers for ventilation and similar
applications.
• Include internal SPDT switch for controlling auxiliary equipment,
additional motors, or to provide a burner interlock switch.
• Spring returns motor to start position on power failure.
• Drive shafts located on both sides of motor.
• Adjustable auxiliary switch for cascading motors or operating
auxiliary equipment.
• Thermal breaker for overload protection during lifting stroke or if
motor stalls.
Dimensions, Approximate: 4 1/2 in. high x 4 5/8 in. wide x 3 3/4 in. Motor Shafts: 2
deep (114 mm high x 118 mm wide x 95 mm deep) Shaft Shape: Hexagonal
Fail Safe Mode: Spring Return Angle of Rotation (Stroke Max (deg)): 75
Control Signal: Two position, SPST Angle of Rotation (Stroke Min (deg)): 75
Internal Auxiliary Switch: 1 Operating Temperature Range: 32 F to 125 F (0 C to 52 C)
External Auxiliary Switches Available: Yes Operating Humidity Range (% RH): 5 to 95% RH
Spring Return Timing (Maximum (seconds)): 25 sec Weight: 4 lb 10 oz (2.1 kg)
Torque Rating, Breakaway: 30 lb-in. Approvals:
Electrical Connections: Screw terminals Underwriters Laboratories, Inc. Listed File: E4436, Guide: XAPX
Frequency: 60 Hz
Mounting: Foot-mounted

Timing Nominal Current Nominal Power


Torque Rating Run Time Opening, Draw (amps) (watts)
(Maximum Nominal Used
Product Number (lb-in.) (Nm) Voltage (seconds)) (seconds) Opening Holding Opening Holding Includes With
* M436A1116 20 lb-in. 2.3 Nm 120 Vac 40 sec Open: 30 sec 0.37 A 0.12 A 28 W 8.5 W — —
* M436A1124 20 lb-in. 2.3 Nm 240 Vac 40 sec Open: 30 sec 0.19 A 0.06 A 29 W 8.5 W — —
M436A1140 20 lb-in. 2.3 Nm 220 Vac 55 sec Open: 30 sec, 0.21 A 0.062 A 30 W 8.5 W Ground and Series 40,
Close: 25 sec cover screw 80 circuits
* M836A1042 20 lb-in. 2.3 Nm 24 Vac 40 sec Open: 30 sec 1.85 A 0.6 A 28 W 8.5 W — —
* M836B1033 15 lb-in. 1.7 Nm 24 Vac 40 sec Open: 25 sec 1.34 A 0.73 A 20.3 W 11.2 W — —
* TRADELINE models • SUPER TRADELINE models

M835 Two-Position Zone Damper Actuator


Two-Position Zone Motor, used with two-wire, 24-volt room
thermostat or other controller for two position damper control.
• Controls zone or changeover damper in heating and air conditioning
systems, and control gates on feeders.
• SPST end switch makes within 20 sec of full open, breaks within 20
sec after start of closing stroke.

Dimensions, Approximate: 5 1/2 in. high x 4 1/4 in. wide x 2 5/8 in. Mounting: Foot-mounted
deep (140 mm high x 108 mm wide x 67 mm deep) Motor Shafts: 2
Fail Safe Mode: Spring Return Shaft Shape: Round
Control Signal: Two position, SPST Angle of Rotation (Stroke Max (deg)): 60
External Auxiliary Switches Available: No Angle of Rotation (Stroke Min (deg)): 75
Torque Rating, Breakaway: 30 lb-in. Operating Temperature Range: Cooling: 140 F, Heating: 200 F
Electrical Connections: Lead wire in conduit box (Cooling: 60 C, Heating: 93 C)
Frequency: 60 Hz Operating Humidity Range (% RH): 5 to 95% RH

Torque Rating Nominal Power (watts)


Product Number (lb-in.) (Nm) Voltage Run Time (Maximum (seconds)) Opening Holding
* M835A1051 4 lb-in. 0.45 Nm 24 Vac Open: 80 sec, Close: 160 sec 27 W 8.5 W
* TRADELINE models • SUPER TRADELINE models

470 customer.honeywell.com 70-6910


Kit Mounted Motors
M847 Two-Position Draft Damper Actuator

Controls
Home
Two-Position Draft Damper Actuators. Use with two-wire 24V room
thermostats or other low voltage controllers to operate the draft
damper on solid fuel furnaces or boilers and other similar light
duty applications.
• Low voltage, spring-return damper actuator.
• Equipped with mounting bracket for wall, duct or direct appliance
mounting to control draft damper through an actuator arm or chain

Indoor Air Quality


linkage arrangement.
• Actuator wheel rotates in a clockwise direction (when facing the
wheel) when energized.

Combustion Controls
Residential
Dimensions, Approximate: 3 1/2 in. high x 2 5/8 in. wide x 3 5/16 in.
deep (89 mm high x 66 mm wide x 84 mm deep) Motor Shafts: 1
Fail Safe Mode: Spring Return Shaft Shape: Round
Control Signal: Two position, SPST Angle of Rotation (Stroke Max (deg)): 45
External Auxiliary Switches Available: No Operating Temperature Range: 40 F to 125 F (5 C to 50 C)
Frequency: 60 Hz Operating Humidity Range (% RH): 5 to 95% RH
Mounting: Foot mounted. Direct Coupled Weight: 1.75 lbs

Hydronic Controls
Torque Rating Run Time
(Maximum
Product Number (lb-in.) (Nm) Voltage (seconds)) Includes
M847A1072 1.9 lb-in. 0.21 Nm 24 Vac 20 sec 3.8 in. linkage arm
M847A1080 1.9 lb-in. 0.21 Nm 24 Vac 20 sec 38 in. linkage chain

Replacement Parts and Accessories for Kit Mounted Motors

Controls
Product

Water
Number Description Used With
121825AA Auxiliary crank arm assembly Q298; M835
126809/0021 M836 Mounting Bracket M836
126816/0021 Clamp for M436 M436
128336/0021 Mounting Bracket for M436/M836, Increases motor height 0.5 inches. M436, M836

Building Automation
16254AC Motor mounting bracket for M436/M836. M436, M836
198545 Motor mounting bracket for M436/M836. M436, M836
4074BRU Bag Assembly Extension adapter and screws for mounting Q607 Auxiliary switch to M436A Q607; M436A
Damper Motor.

M11524

Components
Commercial
4074BRU
4074ELR Crank arm, heavy duty —
4074ELY Crank arm, infinitely adjustable —

Versa Drive Accessories


Pneumatic Controls

Product
Number Description
Q583C1002 Coupler and Bracket for Versadrive Actuator
Industrial Combustion
Controls

70-6910 471
Damper and Valve Linkages
Q100 Linkage
Contains necessary hardware to link Modutrol motors to a V51B
Butterfly Valve.
• Compatible with Modutrol III and Modutrol IV™ motors. (Requires
adapter bracket)
• Adaptable for all sizes of V51B Valves.
• Strain release and stop bracket are provided with V51B.

Linkage Type: Valve


Used with Actuator: Modutrol Motor

Product Number Description


Q100A1015 Linkage for 2 1/2 and 3 in. butterfly valves
Q100A1023 Linkage for 4 in. butterfly valves

Q298 Damper Linkage for Economizer Motors


Connects M833, M835, M836 or M7415 motor to 1 or 2 zone
dampers.
• May be used to link shafts of two dampers together.
• Includes pushrod, ball joints and bushings for 1/4 in. (6 mm) to 1/2 in.
(13 mm) diameter shafts.

Linkage Type: Damper


Used with Actuator: Damper Actuator (M6415, M7405, M7415,
M8415)

Product Number Description Includes


Q298B1065 Damper Linkage Pushrod in variable lengths, 2 damper arms, and 2 ball joints

472 customer.honeywell.com 70-6910


Damper and Valve Linkages
Q605 Damper Linkage

Controls
Home
Connect Modutrol motor to standard damper or set of dampers to
provide control of duct airflow.
• Adjustable to any degree of damper opening. Include ball joints,
motor crank arm and damper arm for 1/2 in. (13 mm) diameter shaft.
• 27520 pushrod must be ordered separately.

Linkage Type: Damper

Indoor Air Quality


Mounting: Mount motor externally on duct
Used with Actuator: Modutrol Motor

Combustion Controls
Shaft
Product Number Dimensions Description Comments Includes

Residential
* Q605A1070 1/2 in. Damper-Linkage with 1/2 inch shaft- Connects Modutrol — Motor bracket, damper arm, motor
motor to water or steam valve crankarm, and 2 ball joints
* Q605D1051 — Damper-Linkage including Motor bracket, 3 damper arms, — Motor bracket, 3 damper arms,
motor crankarm, and 4 ball joints- Connects Modutrol motor to motor crankarm, and 4 ball joints
water or steam valve.
• Q605D1069 — Damper-Linkage including Motor bracket, 3 damper arms, — Motor bracket, 3 damper arms,
motor crankarm, 4 ball joints, left hand drive ear and crankarm motor crankarm, 4 ball joints, left

Hydronic Controls
adapter- Connects Modutrol motor to water or steam valve. hand drive ear and crankarm
adapter
* Q605E1050 — Damper-Linkage including Damper arm, motor crankarm, and — Damper arm, motor crankarm, and
2 ball joints- Connects Modutrol motor to water or steam 2 ball joints
valve.
* Q605F1018 — Damper-Linkage including Motor bracket, damper arm, motor — Motor bracket, damper arm, motor
crankarm, and 2 ball joints- Connects Modutrol motor to water crankarm, and 2 ball joints
or steam valve.
Q605G1009 — Damper-Linkage including Motor bracket, damper arm, motor — Motor bracket, damper arm, motor
crankarm, and 2 ball joints- Connects Modutrol motor to water crankarm, and 2 ball joints
or steam valve.

Controls
Water
Q605H1016 1/2 in. Damper-Linkage including Motor bracket, 3 damper arms, Connects One Mod Motor bracket, 3 damper arms,
motor crankarm, and 4 ball joints- Connects Modutrol motor to IV Motor to Two motor crankarm, and 4 ball joints
water or steam valve. Louver Dampers
• Q605H1024 1/2 in. Damper-Linkage including Motor bracket, 3 damper arms, Connects One Mod Motor bracket, 3 damper arms,
motor crankarm, 4 ball joints, left hand drive ear and crankarm IV Motor to Two motor crankarm, 4 ball joints, left
adapter- Connects Modutrol motor to water or steam valve. Louver Dampers hand drive ear and crankarm
adapter

Building Automation
* Q605J1013 1/2 in. Damper-Linkage with 1/2 inch shaft- Connects Modutrol — Damper arm, motor crankarm, and
motor to water or steam valve 2 ball joints
* TRADELINE models • SUPER TRADELINE models

Q605 Accessories
Used with Actuator: Modutrol Motor

Components
Product Number Description Used With

Commercial
101662A/0021 Motor Mounting Bracket Assembly for Q605 Q605
102931/0021 Adapter arm for less that 90 degree rotation for the Q605 Q605

Pneumatic Controls
Industrial Combustion
Controls

70-6910 473
Damper and Valve Linkages
Q5001 Valve Linkage for Modutrol IV™ Motors
The Q5001 Valve Linkage connects a Modutrol Motor to a 2- or 3-
way valve. It is used primarily on V5011 or V5013 steam and water
valves.
• Q5001 Valve Linkage is applicable to 2-Way or 3-Way valves in
modulating or two-position service.
• Linkage requires no adjustment when used with Honeywell valves
and Modutrol IV™ Motors.
• Q5001 Valve Linkage replaces Q601 and Q618 Valve Linkages.
• Linkage mounts directly to the valve bonnet; motor mounts to linkage
bracket.
• Easy-to-read position indicator.
• Valve stem lift height cam selectable.
• Overtravel permits tight close-off without excessive motor strain.
• Available brackets make linkages adaptable to many valve bodies.
• Models available with 80 lb, 160 lb, and 320 lb stem force.
• Reversible cams on the Q5001 allow field selection of normally open
or normally closed valve operation.
• All models have anti-spin clips.
Linkage Type: Valve Replacement Parts:
Mounting: Linkage mounts directly to the valve bonnet; motor mounts 220845/0767 Retainer button for Q5001
on linkage bracket.
Used with Actuator: Modutrol Motor Accessories:
Stem Force Rating: 80 or 160 lbs (356 N or 712 N) 220829BCQ1 Barber-Colman Valve Adapter Kit
Ambient Temperature Range: -40 F to +150 F (-40 C to +66 C) 220829LGQ3 Landis and Gyr Powers Valve Adapter Kit

Bonnet
Product Number Size (in.) Stroke Description Includes Used With
* Q5001D1000 1 3/8 in. 3/4 in. Valve Linkage for Mod III and Mod IV motors 1 3/8 in. valve bracket V5011/V5013; Modutrol IV Motors
with 80 or 160 lb stem force and Anti spin clip
* Q5001D1018 1 3/8 in. 3/4 in. Valve Linkage for Mod IV motors with 160 or 1 3/8 in. valve bracket Valve sizes up to 3 inch; V5011/
320 lb stem force and up to 3 inch valves and Anti spin clip V5013; Modutrol IV Motors
* Q5001D1026 1 7/8 in. 1 1/2 in. Valve Linkage for Mod IV motors with 160 or 1 7/8 in. valve bracket 4, 5 or 6 inch valves; V5011/V5013;
320 lb stem force and 4, 5 or 6 inch valves and Anti spin clip Modutrol IV Motors
* TRADELINE models • SUPER TRADELINE models

Q5001 parts
Linkage Type: Valve

Product Number Stroke Description Used With


220828AA — Valve bracket assembly, Q5001 Q5001
220845/0767 — Retainer button for Q5001 —
220848A 1/2 in. Q5001 Cam Q5001
220852A — Stroke Indicator, Q5001 Q5001
220858A 9/16 in. 9/16 inch lift Q5001 linkage cam assembly Q5001
220861A 3/4 in. 3/4 inch lift Q5001 linkage cam assembly Q5001
220863A 1 in. 1 inch lift Q5001 linkage cam assembly Q5001
220864A 1 1/8 in. 1 1/8 inch lift Q5001 linkage cam assembly Q5001
220865A 1 1/4 in. 1 1/4 inch lift Q5001 linkage cam assembly Q5001
220867A 1 1/2 in. 1 1/2 inch lift Q5001 linkage cam assembly Q5001
220874/0767 — 9/16 inch anti spin clip for Q5001 —
4074ETB — Antispin Kit, Q5001 Q5001

474 customer.honeywell.com 70-6910


Damper and Valve Linkages
Q5020 Globe Valve Linkages

Controls
Home
The Q5020 Globe Valve Linkages connect a Honeywell direct
coupled actuator (DCA) to a steam or water globe valve. The Q5020
Linkages are compatible with two-way and three-way globe valves
up to 3 inch (DN80).
• Used with two-way and three-way globe valves in modulating or two-
position service.
• Used with 25, 50, and 142 lb-in. spring return and 35, 70, 150, and

Indoor Air Quality


300 lb-in. non-spring return DCA.
• Quick and simple installation with no disassembly required.
• Heavy-duty Steel rack and pinion construction and Aluminum Die-
cast housing.
• Maintenance-free construction.
• Precision roller-bearing rack construction prevents premature valve
packing wear and leakage.
• Flexible actuator mounting orientation.
• Adjustable manual override lever and valve position indicator.

Combustion Controls
• Can be mounted on specific non-Honeywell valves using a
32004629 Bonnet Adapter Kit.

Residential
Linkage Type: Valve
Mounting: Linkage mounts directly to the valve bonnet; actuator
mounts on linkage
Used with Actuator: Direct Coupled Actuator

Bonnet Shaft
Product Number Size (in.) Dimensions Stroke Description Includes Used With

Hydronic Controls
Q5020A1003 1 3/8 in. 1/2 in. 3/4 in. Globe Valve Linkage, 1/2 in. 1/2 in. diameter drive V5011G; V5011F; V5013N;
actuator shaft shaft V5011N
Q5020B1001 1 3/8 in. 1 in. 3/4 in. Globe Valve Linkage, 1 in. 1 in. diameter drive V5011G; V5011F; V5013N;
actuator shaft shaft V5011N
Q5020C1009 1 3/8 in. 1 in. 1 1/2 in. Globe Valve Linkage, 1 in. 1 in. diameter drive V5051
actuator shaft shaft
Q5020D1007 1 3/8 in. 1/2 in. 1/2 in. Globe Valve Linkage, 1/2 in. 1/2 in. diameter drive Siebe valves; Johnson valves;
actuator shaft shaft Siemms valves

Controls
Water
Building Automation
Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 475
Damper and Valve Linkages
Q5022 Globe Valve Tandem DCA Linkage
The Q5022A,B Globe Valve Linkages connect one or two
Honeywell direct coupled rotary actuators (DCA) to a globe valve
for control of chilled water, hot water, or steam. The Q5022A,B
Linkages are compatible with 2 and 3-way globe valves up to 6 in.
(DN150) pipe size.
Q5022A is used to provide enhanced close-off ratings with
Honeywell globe valves up to 3 in. with 1-3/8 in. diameter bonnet
and 3/4 in. stem stroke.
Q5022B is used with Honeywell globe valves 4 to 6 in. with 1-7/8 in.
diameter bonnet and 1-1/2 in. stem stroke.
• For use with 2-way and 3-way globe valves in modulating or two-
position service.
• For use with 175 lb.-in. (S20) spring return or 175 and 300 lb.-in.
(N20, N34) non-spring return DCAs.
• Accepts single or dual matching actuators for higher close-off
pressures.
• Fail-safe operation with spring return DCAs, field selectable normally
open or normally closed for direct or reverse-acting valves.
• Linkage threads onto valve stem.
• Oilite™ self-lubricated actuator shaft bearing.
• Anodized extruded aluminum housing.
• Maintenance-free construction.
• Precision roller-bearing rack construction to prevent premature valve
packing wear and leakage.
• Flexible actuator mounting orientation.

Dimensions in inches (millimeters)


Linkage Type: Valve
STEM STROKE Mounting: Linkage mounts directly to the valve bonnet; actuator(s)
3-1/2 1-1/8 5022A 3/4 (19) 4-7/8 mount on linkage
(89) (28) 5022B 1-1/2 (38) (124) Used with Actuator: Direct Coupled Actuator
2-1/2 Stem Force Rating: 1117 max. (4969 max.)
(64) Comments: This linkage is not compatible with the 43196000 high
temperature kits
Includes: Anti-spin brackets
8
(203)

STROKE “Y”
MAX 6-1/4 (159)
MIN 2-15/16 (75)
3/4 (19)

2-1/2 M27644
(63)

Bonnet Size
Product Number (in.) Shaft Dimensions Stroke Description Used With
Q5022A1001 1 3/8 in. 1/4 -28UNF-2A 3/4 in. Tandem DCA linkage for Honeywell threaded and flanged VGF under 4 in.; V5013;
globe valves 3 inches and smaller V5011
Q5022B1009 1 7/8 in. 7/16 -20UNF-2A 1 1/2 in. Tandem DCA linkage for Honeywell flanged globe valves 4 VGF over 3 in.; V5013;
inches and larger V5011

476 customer.honeywell.com 70-6910


Damper and Valve Linkages
Wiring and configuring modulating tandem actuators with Q5022 Wiring of tandem floating actuators with Q5022 linkages

Controls
Home
linkages

3
4
TYPICAL SPDT
1 24 VAC ACTUATOR CONTROLLER MN6134 2
2 1 3 1 L1
V
24 Vac 1
2 W L2
1 24 VAC

Indoor Air Quality


1 2
3 OR + B R
4
0/2 TO 10 VDC 4 OR N/A
PROPORTIONING
CONTROLLER 5 FEEDBACK 4
MN6134
HOT 2-10 VDC
10-2 VDC 3 1
COM 3 0-10 VDC
10-0 VDC 1 2

Combustion Controls
– Fltg, fwd
Fltg, rev
4

Residential
+

ACTUATOR 1 POWER SUPPLY PROVIDES OVERLOAD PROTECTION AND DISCONNECT


MEANS.
1
1 24 VAC V
2 2 ALLOW UP TO 0.5 AMPS FOR EACH DEVICE. ACTUATORS AND
2 CONTROLLER CAN SHARE SAME TRANSFORMER, PROVIDED THAT THE
VA RATING OF THE TRANSFORMER IS NOT EXCEEDED AND PROPER
3 OR +
PHASING IS OBSERVED. DO NOT MIX A.C. AND D.C. POWER SOURCES.
4 OR N/A

Hydronic Controls
1 LINE VOLTAGE POWER SUPPLY. 3 CONTROLLER CAN BE LOW VOLTAGE SPDT SERIES 20 “ON-OFF” OR
PROVIDE DISCONNECT MEANS AND 5 FEEDBACK SP3T SERIES 60 “FLOATING” (TRI-STATE) TYPE.
OVERLOAD PROTECTION AS REQUIRED.
2-10 VDC 4 MULTIPLE ACTUATORS CONTROLLED BY A COMMON CONTROLLER IN
2 24 VDC SUPPLY ACCEPTABLE. PARALLEL MUST BE WIRED SO THAT THEY ALL ROTATE IN THE SAME
10-2 VDC
0-10 VDC DIRECTION. M27648
3 SET SWITCH TO MODULATING. ONE 3
OF THE ACTUATORS MUST BE SET
10-0 VDC
FOR REVERSE RESPONSE OVER THE Fltg, fwd
SAME INPUT SIGNAL SPAN. WIRE USING Fltg, rev
SHIELDED CABLE WHEN USING 0-10 OR
10-0V SIGNAL SPAN GROUND SHIELD AT
CONTROLLER ONLY.

Controls
4 ENSURE PROPER GROUNDING OF ACTUATOR CASE.

Water
DO NOT GROUND SIGNAL COMMON. M27710

Damper and Valve Linkage Accessories


Linkage Type: Damper

Building Automation
Product Number Description Includes Used With
102546 Ball Joint, 5/16 in. — Damper Linkages
104643A Adapter for driving 2 dampers from 1 crank arm — Kit Mounted Motors;
Modutrol IV™ Motors
26025F Damper Arm, 3/8 in. shaft — —
26026B Damper Arm, 1/2 in. shaft, 3 in. long — —
32004629-001 Bonnet adapter kit to adapt Seimens (Landis/Power) Flowrite 599 1/2 — Siemms valves
inch to 3 inch globe valves with Q5020A or Q5009B

Components
Commercial
32004629-002 Bonnet Adapter Kit, Johnson Controls 1/2 to 3/4 in., Q5020 — Johnson valves; Q5020
32004629-003 Bonnet Adapter Kit, Johnson Controls 1 to 2 in., Q5020 — Johnson valves; Q5020
32004629-004 Bonnet Adapter Kit, Siebe 1/2 to 2 in., Q5020 — Siebe valves; Q5020
7617ACL Bag Assembly, Q605 Damper arm, motor crankarm, and 2 Q605
ball joints
Pneumatic Controls
Industrial Combustion
Controls

70-6910 477
Carbon Dioxide (CO2) Sensors
C7232 Carbon Dioxide (CO2) Sensors
necessity with HVAC controllers. The sensor measures the CO2
concentration in the ventilated space or duct. The sensors are
used in ventilation and air conditioning systems to control the
amount of fresh outdoor air supplied to maintain acceptable levels
of CO2 in the space.
• Models available with LCD that provides sensor readings and status
information.
• Non-Dispersion-Infrared (NDIR) technology used to measure carbon
dioxide gas.
• Gold-plated sensor provides long-term calibration stability.
• C7232 provides voltage or current output based on CO2 levels.
• SPST relay output.
• Used for CO2 based ventilation control (Demand Control Ventilation
(DCV)).
The Carbon Dioxide (CO2) Sensors and Controllers are stand-alone • Automatic Background Calibration (ABC) algorithm based on long-
carbon dioxide (CO2) sensors for use in determining ventilation term evaluation reduces required typical zero-drift check
maintenance.
Carbon Dioxide Range: 0 to 2000 ppm, adjustable Voltage: 24 Vac/dc ±20%,
Analog Current Output: 0/2 - 10 Vdc or 0/4 - 20 mA selectable, w/ one Frequency: 60 Hz; 50 Hz
relay output Response Time: 1 minute
Electrical Connections: Six leadwires, 20-gauge, 8 in. long Sensor Type: Non-dispersive Infrared (NDIR)
Contact Ratings: 1 A @ 50 Vac/24 Vdc Operating Temperature Range: 32 F to 122 F (0 C to 50 C)
Relay Output: One: Normally Open SPST Accuracy: (5% full scale)

Dimensions, Approximate
Product Number Display Mounting (inch) (mm) Includes
C7232A1008 Yes Wall mount 5 1/16 in. high x 3 11/16 in. wide x 2 in. deep 128 mm high x 80 mm wide x 25 mm deep Honeywell Logo
C7232A1016 No Wall mount 5 1/16 in. high x 3 5/32 in. wide x 2 in. deep 128 mm high x 80 mm wide x 25 mm deep Honeywell Logo
C7232A1024 Yes Wall mount 5 1/16 in. high x 3 5/32 in. wide x 2 in. deep 128 mm high x 80 mm wide x 25 mm deep No Honeywell Logo
C7232A1032 No Wall mount 5 1/16 in. high x 3 5/32 in. wide x 2 in. deep 128 mm high x 80 mm wide x 25 mm deep No Honeywell Logo
C7232B1006 Yes Duct mount 5 5/8 in. high x 3 5/16 in. wide x 3 7/16 in. 142 mm high x 84 mm wide x 87 mm deep Honeywell Logo
deep x plus 8 in. long sensing tube x plus 203 mm sensing tube
C7232B1014 No Duct mount 5 5/8 in. high x 3 5/16 in. wide x 3 7/16 in. 142 mm high x 84 mm wide x 87 mm deep Honeywell Logo
deep x plus 8 in. long sensing tube x plus 203 mm sensing tube
C7232B1022 Yes Duct mount 5 5/8 in. high x 3 5/16 in. wide x 3 7/16 in. 142 mm high x 84 mm wide x 87 mm deep No Honeywell Logo
deep x plus 8 in. long sensing tube x plus 203 mm sensing tube
C7232B1030 No Duct mount 5 5/8 in. high x 3 5/16 in. wide x 3 7/16 in. 142 mm high x 84 mm wide x 87 mm deep No Honeywell Logo
deep x plus 8 in. long sensing tube x plus 203 mm sensing tube

478 customer.honeywell.com 70-6910


Carbon Dioxide (CO2) Sensors
C7632 Carbon Dioxide (CO2) Sensors

Controls
Home
The Carbon Dioxide (CO2) Sensors offer a fixed 0-2000ppm and
fixed 0-10Vdc output. No adjustments are necessary. Like the
C7232 sensors, these are for use in determining ventilation
necessity with HVAC controllers. The sensor measures the CO2
concentration in the ventilated space or duct. The sensors are
used in ventilation and air conditioning systems to control the

Indoor Air Quality


amount of fresh outdoor air supplied to maintain acceptable levels
of CO2 in the space.
• Non-Dispersion-Infrared (NDIR) technology used to measure carbon
dioxide gas.
• Gold-plated sensor provides long-term calibration stability.
• Fixed 0-2000ppm, fixed 0-10Vdc output.
• Used for CO2 based ventilation control (Demand Control Ventilation
(DCV)).
• Automatic Background Calibration (ABC) algorithm based on long-

Combustion Controls
term evaluation reduces required typical zero-drift check
maintenance.

Residential
Carbon Dioxide Range: 0 to 2000 ppm, fixed Frequency: 60 Hz; 50 Hz
Analog Current Output: 0-10Vdc fixed Response Time: 1 minute
Electrical Connections: Terminal block Sensor Type: Non-dispersive Infrared (NDIR)
Relay Output: None Operating Temperature Range: 32 F to 122 F (0 C to 50 C)
Voltage: 24 Vac (±20%) Accuracy: (5% full scale)

Dimensions, Approximate

Hydronic Controls
Product Number Display Mounting (inch) (mm) Includes
C7632A1004 No Wall mount 4 1/8 in high x 3 7/8 in. wide x 1 1/16 in. deep 104mm high x 99 mm high x 27 mm deep Honeywell Logo
C7632B1002 No Duct mount 5 5/8 in. high x 3 5/16 in. wide x 1 13/16 in. 142 mm high x 84 mm wide x 87 mm deep x Honeywell Logo
deep x plus 8 in. long sensing tube plus 203 mm sensing tube

Controls
Water
Building Automation
Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 479
Current Switches
Solid and Split Core Current Switches
in applications in which a "Go/No Go" current switch is required.
The current switches can be used to monitor devices with a
maximum continuous operating current of up to 250 Amps. These
current switches do not need to be externally powered, since the
power for the switch is induced from the conductor being
monitored. The split core switches are ideal for retrofit or existing
installations, since it is not necessary to power down the unit and
disconnect any wires during the installation process. Solid core
switches are extremely easy to install, they are an excellent choice
for new installations.
• Solid or split core switches with fixed or adjustable trip points
• Very low operating trip points
• LED status indication
• Integral DIN rail mounting flange
• Accepts up to a 350 MCM (17.3 mm) cable
• Operates up to 250 continuous amps
All of these sensors have a solid-state output with an adjustable or • RoHS and WEEE Compliant
fixed trip point (setpoint). These current switches should be used • Limited 5 year warranty

Dimension Diagrams: See page 481

Application: Great for monitoring fans, pumps, motors, compressors, Operating Temperature Range: 5 F to 104 F (-15 C to 40 C)
or other electrical equipment Operating Humidity Range (% RH): 0 to 95% RH, non-condensing
Din Rail Size: 1-3/8 in. (35 mm) Weight: 0.23 lb (0.1 kg)
LEDs: Red – Above the trip point; Green – Below the trip point Approvals:
Enclosure Rating/Color: UL94-5V/Burgundy CE: Approved
Isolation Voltage: 2200 Vac Underwriters Laboratories, Inc. Approved
Supply Voltage: Induced from monitored conductor Environmental Compliance: RoHS-Directive 2002/95/EC, WEEE-
Frequency: 40 Hz to 1 kHz Directive 2002/96/EC
Operating Range: 0-250A

Core Normal
Product Number Description Type Position Output Switch Rating Trip Point LEDs
CSP-C-A200-001 Adjustable Current Switch Split N.C. 0.15 Amps @ 300 Vac/Vdc 2.5-250 Amps Green – Below the trip point;
Red – Above the trip point
CSP-O-A200-001 Adjustable Current Switch Split N.O. 0.30 Amps @ 200 Vac/Vdc 2.0-200 Amps Green – Below the trip point;
Red – Above the trip point
CSP-O-A300-001 Adjustable Current Switch Split N.O. 0.30 Amps @ 200 Vac/Vdc 3.0-200 Amps Green – Below the trip point;
Red – Above the trip point
CSP-O-F10-001 Go/No Go Current Switch Split N.O. 0.30 Amps @ 200 Vac/Vdc 1.50 Amps Red – Above the trip point
CSP-O-F15-001 Go/No Go Current Switch Split N.O. 0.30 Amps @ 200 Vac/Vdc 2.50 Amps Red – Above the trip point
CSS-C-F1-001 Go/No Go Current Switch Solid N.C. 0.15 Amps @ 300 Vac/Vdc 0.50 Amps Red – Above the trip point
CSS-C-F5-001 Go/No Go Current Switch Solid N.C. 0.15 Amps @ 300 Vac/Vdc 1.00 Amps Red – Above the trip point
CSS-O-A200-001 Adjustable Current Switch Solid N.O. 0.30 Amps @ 200 Vac/Vdc 0.5-250 Amps Green – Below the trip point;
Red – Above the trip point
CSS-O-A300-001 Adjustable Current Switch Solid N.O. 0.30 Amps @ 200 Vac/Vdc 1.0-250 Amps Green – Below the trip point;
Red – Above the trip point
CSS-O-F1-001 Go/No Go Current Switch Solid N.O. 0.30 Amps @ 200 Vac/Vdc 0.20 Amps Red – Above the trip point
CSS-O-F5-001 Go/No Go Current Switch Solid N.O. 0.30 Amps @ 200 Vac/Vdc 0.50 Amps Red – Above the trip point

480 customer.honeywell.com 70-6910


Current Switches
Split Core Dimensions in inches (millimeters)

Controls
Home
TOP VIEW

TRIP TRIP 7/32 (6)


TRIP OFF ON
ADJ TYP.
TRIP ON = Above Trip Point
Adj. Range: 2.0-250A

Indoor Air Quality


1/2 (13) Output: 0.3A @
200 VDC/VAC

2-27/32 (72)

LEFT SIDE VIEW FRONT VIEW RIGHT SIDE VIEW

Combustion Controls
U

Residential
C RL US

2-45/64
TERMINAL (69)
BLOCK 49/64
3/4 (19)
(19)

Hydronic Controls
9/64 (4)
1-3/8 (35)
1-5/64 (25)
3-21/64 (85)
M23580

Solid Core Dimensions in inches (millimeters)

TOP VIEW

Controls
Water
TRIP 13/64 (5)
ON
TRIP ON = ABOVE 0.5A
TYP.
INPUT: 250A MAX
OUTPUT: 0.3A @
13/32 (10) 200 VDC/VAC

2-27/32 (72)

Building Automation
LEFT SIDE VIEW FRONT VIEW RIGHT SIDE VIEW

25/32
(20)

2-17/64
(58)

Components
Commercial
TERMINAL
BLOCK

C U
® L US

9/64 (4)
1-3/8 (35)
63/64 (25)
3-3/8 (86)
Pneumatic Controls

M23579
Industrial Combustion
Controls

70-6910 481
Current Switches
Solid and Split Core Current Transmitters
which can be monitored by a building management controller.
These current sensors should be used in load trending (current
monitoring) type applications. The split core transmitters are ideal
for retrofit or existing installations, since it is not necessary to
power down the unit and disconnect any wires during the
installation process. Solid core transmitters are extremely easy to
install, they are an excellent choice for new installations.
• Solid or split core loop-powered current transmitters for 4-20 mA
models
• Solid or split core 0-5 or 0-10 Vdc models
• Fast response time
• Integral DIN rail mounting flange
• Easy wiring, polarity sensitive output
• Accepts up to a 350 MCM (17.3 mm) cable
• Operates up to 250 continuous amps
• True RMS versions are available
• RoHS and WEEE Complaint
Depending on model selected the current is converted into a linear • Limited 5 Year Warranty
and proportional output signal of 0-5 Vdc, 0-10 Vdc or 4-20 mA,
Dimension Diagrams: See page 481 Operating Temperature Range: 5 F to 104 F (-15 C to 40 C)
Application: Ideal for retrofit or existing installations requiring load Operating Humidity Range (% RH): 0 to 95% RH, non-condensing
trending (current monitoring) Weight: 0.24 lb (0.1 kg)
Din Rail Size: 1-3/8 in. (35 mm)
Approvals:
Enclosure Rating/Color: UL94-5V/Burgundy CE: Pending
Maximum Load Resistance: 650 Ohms @ 24 Vdc (Vs-10)/0.02-40.2 Underwriters Laboratories, Inc. Approved
Isolation Voltage: 2200 Vac Environmental Compliance: RoHS-Directive 2002/95/EC, WEEE-
Supply Current: 36 mA max Directive 2002/96/EC
Type: Adjustable

Core Output Switch Response


Product Number Description Type Rating Current Range Time Supply Voltage Frequency
CTP-20-050-VFD-001 Loop Powered Split 4-20 mA Average 0-50 Amps; 0-20 Amps; <200 mS 12 to 30 Vdc 30 Hz to 1 kHz
Current Sensor True RMS 0-10 Amps
CTP-20-200-AVG-001 Loop Powered Split 4-20 mA Average 0-150 Amps; 0-200 <75 mS 12 to 30 Vdc 30 Hz to 1 kHz
Current Sensor Amps; 0-100 Amps
CTS-05-050-VDC-001 Current Sensors Solid 0 to 5 Vdc 0-50 Amps; 0-20 Amps; <100 mS Induced from 50 Hz to 600 Hz
0-10 Amps monitored conductor
CTS-10-250-VDC-001 Current Sensors Solid 0 to 10 Vdc 0-250 Amps; 0-200 <100 mS Induced from 50 Hz to 600 Hz
Amps; 0-100 Amps monitored conductor
CTS-20-250-AVG-001 Loop Powered Solid 4-20 mA Average 0-250 Amps; 0-200 <75 mS 12 to 30 Vdc 30 Hz to 1 kHz
Current Sensor Amps; 0-100 Amps
CTS-20-250-VFD-001 Loop Powered Solid 4-20 mA Average 0-250 Amps; 0-200 <200 mS 12 to 30 Vdc 30 Hz to 1 kHz
Current Sensor True RMS Amps; 0-100 Amps

482 customer.honeywell.com 70-6910


Dew Point Sensors
Dew Point Sensor

Controls
Home
This early-warning dew-point sensor is designed for use in
monitoring cooling water pipes or chilled surfaces in order to
determine if temperatures are approaching the dewpoint.
It is suitable for mounting on flat and round surfaces. The sensor
measures the relative humidity prevailing directly at the chilled
surface and can thus be used to regulate cooling performance, or

Indoor Air Quality


switch cooling systems ON and OFF. and signal if the temperature
is approaching the dew point.
Using this sensor, it is thus possible to operate e.g. chilled ceilings
in an optimal manner and without the formation of condensation
water even under critical climatic conditions.
• Does not wait to detect when the dew-point has already been
reached, but rather provides an early warning of the approaching
dew-point
• Compact design

Combustion Controls
• Fast response
• Module is coated, thus protected against contamination

Residential
• Simple and easy mounting
Application: For use in monitoring cooling water pipes or chilled Operating Humidity Range (% RH): 5–95% RH, non-condensing
surfaces in order to determine if temperatures are approaching the Power Consumption: < 10 mA
dew point. Voltage: 60 Vdc
Dimensions, Approximate: 1/16 in. high x 1 1/4 in. wide x 2 in. deep Mounting: Flat and round surfaces
(15.5†mm high x 32†mm wide x 50†mm deep)

Hydronic Controls
R.H.
Supply Hysteresis Switching
Product Number ON Voltage Voltage Switching Switch Points Current Output Type Response Time
H7018A1003 100 mV @ 15 mA 24 Vac ±20% 5% RH Contact Closed @ <90% RH 15 mA max Potential-Free ~3 min (given a jump in
Contact Open @ > 90% RH Contact the relative humidity of
from 55% to 100%)

Controls
Water
Building Automation
Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 483
Humidity Sensors
C7600 Humidity Sensor
Used with any controller capable of processing a 4-20 mA or 2-10
Vdc signal.
• Provide humidity sensing through a long-lasting thick-film capacitive
polyimide sensing element that is both accurate and stable over
time.
• Vents in top cover provide for airflow to humidity sensing element
inside.
• Mounts easily because of compact size and lightweight construction.
• Remains operational after exposure to all outdoor air humidity
extremes. 5% RH accuracy from 30% to 70% RH.

Dimensions in inches (millimeters)


1-13/16 (46)
5/16 (8) 7/32 (6)

3-1/4
2-3/4 (83)
(70)
4-5/8
(117)
3-5/32
(80)
3-13/16
(97)

9/16 3-7/8 (96)


(14)
1 (25) M3129A 7/8 (22) 3/8 2-7/8 (73)
1-1/16 (27) (10) 3-5/8 (92)
M17720

Application: Humidity Shipping Temperature Range: -40 F to +150 F (-40 C to +65 C)


Operating Temperature Range: 32 F to 125 F (0 C to 52 C) Operating Humidity Range (% RH): 10 to 90% RH, non-condensing

Product Number Application Type Mounting Sensor Type Comments Used With
C7600A1002 Duct mount Duct or Wall mount 4-20 mA inversely proportional Two 1/4 in. quick-connect terminals W7600
C7600B2008 Junction box mount Wall mount 2-10Vdc directly proportional Three 22-gauge wires T775U
C7600C1008 Duct mount Duct or Wall mount 4-20mA directly proportional Two 1/4 in. quick-connect terminals T775U

484 customer.honeywell.com 70-6910


Humidity Sensors
H7012 Humidity and Temperature Room Sensors

Controls
Home
Wall-mounted, capacitance type relative humidity room sensor.
• Capacitance type sensing element.
• Wide sensing range.
• Temperature indication sensor, H7012B only.

Application: Humidity
Dimensions, Approximate: 5 1/8 in. high x 3 3/16 in. wide x 1 11/32 in.

Indoor Air Quality


deep (130 mm high x 81 mm wide x 34 mm deep)
Operating Humidity Range (% RH): 30 to 70% RH

Combustion Controls
Product Number Mounting Sensor Type Description Comments
H7012A1009 Wall mount — Humidity Sensor Capacitance type humidity sensor

Residential
H7012B1007 Wall mount PT1000 Humidity and Temperature Sensor Capacitance type humidity sensor
H7012B1015 Wall mount Balco 500 Humidity and Temperature Sensor Capacitance type humidity sensor

H7015B Humidity Transducers


The H7015B Combined Humidity/Temperature Duct Sensor

Hydronic Controls
combines a capacitance-type relative humidity sensor with a
PT1000 or BALCO 500 temperature sensor in one housing. These
sensors can be used for discharge, outside or return air control or
as a high-limit sensor in applications such as steam
humidification.
• Wide sensing range.
• Capacitance type sensing element for relative humidity.
• PT1000 or BALCO 500 temperature sensing element.

Dimensions in inches (millimeters)


Application: Humidity Sensor

Controls
Dimensions, Approximate: 4 3/4 high, 3 1/8 in. wide, 2 3/16 in. deep

Water
3-1/8 (80) 9/16 (14) 2-3/16 (55)
12-3/4 (323) (120 mm high, 82 mm wide, 55 mm deep)
Operating Temperature Range: -22 F to 158 F (-30 C to 70 C)
Operating Humidity Range (% RH): 10 to 90% RH, non-condensing
1/2
(12)

Building Automation
GASKET 4-3/4
DISTANCE (120)
VARIABLE
BY CLAMP

CLAMP

1/4 (7) DIA.


CABLE ENTRY M4586A

Product Number Mounting Description Comments

Components
Commercial
H7015B1004 Duct mount Humidity and Temperature Duct Mounted Sensors With PT1000 Temperature Sensor
H7015B1012 Duct mount Humidity and Temperature Duct Mounted Sensors With Balco 500 Temperature Sensor

Pneumatic Controls
Industrial Combustion
Controls

70-6910 485
Humidity Sensors
H7625, H7635, and H7655 Humidity and Temperature Transmitters
The H7625, H7635, and H7655 are highly accurate, stable humidity
transducers designed for use with HVAC controllers such as the
T7350 Thermostat, T775U Remote Humidity Controller, and W7760
Direct Digital Controllers. The Ceramic Technology humidity
sensor is not affected by condensation and provides excellent
long-term stability.
• Ceramic Technology overcomes the limitations of other resistance
based humidity sensors that use water soluble polymer coatings.
• Ceramic Technology allows sensors to recover fully from
condensation, fog, and high humidity.
• Highly accurate, repeatable, stable output with negligible hysteresis.
• Temperature compensated output. Zero and span trimmers, and
increment/decrement recalibration feature.
• All units have selectable 4-20 mA, 0-10 Vdc, or 0-5 Vdc output. NIST
traceable 2%, 3%, and 5% calibration, every sensor calibrated at 3
different points.
H7655A • All humidity sensors use the same enclosure as the T7770 sensor,
except the H7655A, which uses the T7047-like enclosure.
Application: Humidity and Temperature
H7625A Voltage: 18-36Vdc or 18-28Vac
H7635A
Operating Temperature Range: -10 F to 160F (-23C to 70C)
Shipping Temperature Range: -40 F to +150 F (-40 C to +65 C)
Operating Humidity Range (% RH): 0 to 100% RH

H7625B
H7635B,C
H7655B

Application Accuracy Temperature


Product Number Type (% RH) Output Humidity Output Comments Used With
H7625A1008 Wall mount 2% from 20- 20K ohm NTC 4-20mA, 0-5Vdc, or Ceramic resistance humidity sensor Excel 15, Excel 10, T7350,
95% RH 0-10Vdc selectable T775 Series 2000
H7625B1006 Duct mount 2% from 20- 20K ohm NTC 4-20mA, 0-5Vdc, or Ceramic resistance humidity sensor Excel 15, Excel 10, T7350,
95% RH 0-10Vdc selectable T775 Series 2000
H7635A1006 Wall mount 3% from 20- 20K ohm NTC 4-20mA, 0-5Vdc, or Ceramic resistance humidity sensor Excel 15, Excel 10, T7350,
95% RH 0-10Vdc selectable T775 Series 2000
H7635B1004 Duct mount 3% from 20- 20K ohm NTC 4-20mA, 0-5Vdc, or Ceramic resistance humidity sensor Excel 15, Excel 10, T7350,
95% RH 0-10Vdc selectable T775 Series 2000
H7635C1002 Outdoor 3% from 20- 20K ohm NTC 4-20mA, 0-5Vdc, or Ceramic resistance humidity sensor XL products where needed,
mount 95% RH 0-10Vdc selectable T775 Series 2000
H7655A1001 Wall mount 5% from 30- none 0-10Vdc Uses different enclosure (same as XL15, XL10, T7350
70% RH T7047 Sensor).Polymer capacitance
humidity sensor
H7655B1009 Duct mount 5% from 20- 20K ohm NTC 4-20mA, 0-5Vdc, or Ceramic resistance humidity sensor Excel 15, Excel 10, T7350
95% RH 0-10Vdc selectable

486 customer.honeywell.com 70-6910


Humidity Sensors
Dimensions in inches (millimeters)

Controls
Home
4-11/16 (119) 3/4
1 (19)
(25) 3-15/16 (100)
KNOCKOUTS 2-3/8 (60) 7/8
FOR (22)
EUROPEAN
APPLICATIONS STANDARD

Indoor Air Quality


UTILITY 2-1/4
5-1/16 CONDUIT
2-3/8 (57)
(128) BOX
(60)
(2X4)
MOUNTING
HOLES

KNOCKOUTS
(3)

Combustion Controls
3-5/32 (80) M17540A

Residential
1-13/16 (46)

3-1/4
(83)

4-5/8

Hydronic Controls
(117)
6-1/2
(165)
3-13/16 3-3/4
(97) (95)

7/8 (22) 3/8 2-7/8 (73)


1-1/16 (27) (10) 3-5/8 (92)

Controls
M17720

Water
1-3/8
(36) M22584

Building Automation
Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 487
Pressure Sensors
P7640 Differential Pressure Transmitters
The P7640 Pressure Sensors are designed with field-selectable 4-
20 mA, 0-5 Vdc, or 0-10 Vdc output. The P7640 offers switch
selectable pressure ranges between 0-1 in. w.c./0-250 Pa or 0-10 in.
w.c./0-2500PA depending on the model. Pressure ranges can be
set for either uni-directional or bi-directional.
• The P7640A Panel Mount, P7640B Duct Mount and P7640U
Universal Mount Differential Pressure Transmitters provide reliable,
accurate measurement and control.
• Proper applications include measurement of extremely low pressure
applications such as: building/room pressure, air flow, variable air
volume, filter status, and duct pressure.
• They are ideal for clean rooms, hospitals, fume hoods, and computer
Duct Mount without Display rooms.
Duct Mount with Display • Selectable inches w.c. or Pascal scale.
• Selectable fast or standard response time.
• Duct mount model comes with factory installed duct probe.
• The Universal model comes with attachable duct probe and can be
used in either panel or duct mounting application.

Universal Mount without Display

Dimensions in inches (millimeters)


Connection Size: Pneumatic:1/4 in. Brass Hose Barb, Electrical:
8 2-1/8 3-5/16 Unpluggable screw terminal block
(203) (54) (84) Output: 4-20mA, 0-5Vdc or 0-10Vdc selectable
Temperature Range: 32F to 140F (0C to 60C)
Accuracy: (±1% Full Scale)
Burst Pressure: 5 psi
Proof Pressure: 3 psi
4-1/2 Electrical Termination: Voltage: 12 to 30 Vdc or 24 Vac
(114)

1
1/4
(6)

1/2
(13)
1 P7640B ONLY. THE P7640A HAS NO PROBE.
M22581

Pressure Ranges
Product Number (Pa) (in. wc) Mounting Output Display
P7640A1000 0-25, 0-50, 0-100, 0-250 Pa uni- or bi- 0-1.0, 0-0.5, 0-0.25, or 0-0.1 inches Panel mount 4-20mA, 0-5Vdc or Yes
directional w.c., uni- or bi-directional 0-10Vdc selectable
P7640A1018 0-25, 0-50, 0-100, 0-250 Pa uni- or bi- 0-1.0, 0-0.5, 0-0.25, or 0-0.1 inches Panel mount 4-20mA, 0-5Vdc or No
directional w.c., uni- or bi-directional 0-10Vdc selectable
P7640A1026 0-250, 0-500, 0-1000, 0-2500 Pa uni- 0-10, 0-5, 0-2.5, or 0-1 inches w.c., uni Panel mount 4-20mA, 0-5Vdc or Yes
or bi-directional or bi-directional 0-10Vdc selectable
P7640A1034 0-250, 0-500, 0-1000, 0-2500 Pa uni- 0-10, 0-5, 0-2.5, or 0-1 inches w.c., uni Panel mount 4-20mA, 0-5Vdc or No
or bi-directional or bi-directional 0-10Vdc selectable
P7640B1008 0-25, 0-50, 0-100, 0-250 Pa uni- or bi- 0-1.0, 0-0.5, 0-0.25, or 0-0.1 inches Duct mount, integral 4-20mA, 0-5Vdc or Yes
directional w.c., uni- or bi-directional 8 in. probe 0-10Vdc selectable
P7640B1016 0-25, 0-50, 0-100, 0-250 Pa uni- or bi- 0-1.0, 0-0.5, 0-0.25, or 0-0.1 inches Duct mount, integral 4-20mA, 0-5Vdc or No
directional w.c., uni- or bi-directional 8 in. probe 0-10Vdc selectable
P7640B1024 0-250, 0-500, 0-1000, 0-2500 Pa uni- 0-10, 0-5, 0-2.5, or 0-1 inches w.c., uni Duct mount, integral 4-20mA, 0-5Vdc or Yes
or bi-directional or bi-directional 8 in. probe 0-10Vdc selectable
P7640B1032 0-250, 0-500, 0-1000, 0-2500 Pa uni- 0-10, 0-5, 0-2.5, or 0-1 inches w.c., uni Duct mount, integral 4-20mA, 0-5Vdc or No
or bi-directional or bi-directional 8 in. probe 0-10Vdc selectable
P7640U1040 0-25, 0-50, 0-100, 0-250, 0-500, 0- 0-0.1, 0-0.25, 0-0.5, 0-1, 0-2.5, 0-5, or Universal 4-20mA, 0-5Vdc or No
1000, 0-2500 Pa uni- or bi-directional 0-10 inches w.c., uni or bi-directional 0-10Vdc selectable
P7640U1052 0-25, 0-50, 0-100, 0-250, 0-500, 0- 0-0.1, 0-0.25, 0-0.5, 0-1, 0-2.5, 0-5, or Universal 4-20mA, 0-5Vdc or Yes
1000, 0-2500 Pa uni- or bi-directional 0-10 inches w.c., uni or bi-directional 0-10Vdc selectable

488 customer.honeywell.com 70-6910


Pressure Sensors
PWT Series Wet/Wet Differential Pressure Sensors

Controls
Home
The PWT Series wet/wet differential pressure sensors provide
reliable, accurate measurement and control of many applications,
including pump differential pressure, chiller/boiler differential
pressure drop, and CW/HW system differential pressure.
• The PWT Pressure Sensors incorporate microprocessor profiled
sensors for exceptional accuracy and reliability.
• Field-selectable 4-20 mA, 0-5 Vdc, or 0-10 Vdc output.

Indoor Air Quality


• Jumper-selectable slow or fast response time.
• Switch-selectable pressure ranges.
• The jumper-selectable output switch for normal (4-20 mA) or reverse
(20-4mA) operation provides application flexibility.
• Rugged, die-cast enclosure provides NEMA 4 sealing.
• Jumper-selectable port swap feature.
Panel Mount • All models offer both push button and digital input to zero the output.
with Display
Dimensions, Approximate: 4 in. high x 5 51/64 in. wide x 2 13/64 in.

Combustion Controls
deep (102 mm high x 147 mm wide x 57 mm deep)
Connection Size: 1/8 in. NPT female, stainless steel 17-4 PH

Residential
Output: 4-20mA, 0-5Vdc or 0-10Vdc selectable
Operating Temperature Range: 14 F to 131 F (-10 C to 55 C)
Burst Pressure: 5x max. F.S. range
Proof Pressure: 2x max. F.S. range
Bypass Valve Supply Voltage: 12 to 30 Vdc or 24 Vac
Assembly
Approvals:
CE: CE

Hydronic Controls
Product Number Accuracy Pressure Ranges (psi) Display Description
PWT50 ±1% F.S. for 0-10, 0-25, 0-50 psid; 0-5, 0-10, 0-25, 0-50 psid Yes Wet Differential Pressure Transmitter
±2% F.S. for 0-5 psid
PWT250 ±1% F.S. for 0-250, 0-125, & 0-50 psid; 0-25, 0-50, 0-125, 0-250 psid Yes Wet Differential Pressure Transmitter
±2% F.S. for 0-25 psid
PWT100 ±1% F.S. for 0-100, 0-50, 0-20 psid; 0-100, 0-50, 0-20, 0-10 psid Yes Wet Differential Pressure Transmitter
±2% F.S. for 0-10 psid

Controls
Water
PWT-BV — — — Bypass Valve Manifold

Gauge Pressure Sensors


The 50035430 Series is a two-wire 4-20mA gauge pressure sensor.
This digitally compensated sensor offers an unparalleled value and

Building Automation
performance combination, making it the ideal pressure sensing
solution for demanding applications. The 50035430 series is
available in pressure ranges up to 1000 psi.
• Available in 50, 150, 300, 500 and 1000 psi.
• All metal wetted parts for use in wide variety of fluid applications.
• Suitable for use with freon and ammonia based cooling systems.
• No internal elastomeric seals mean no o-ring compatibility issues.
• Less than 2 ms response time provides accurate, high speed
measurement.
• Select models available with 1/4-in. SAE female Schrader
connection with valve depressor.

Components
Commercial
Output: 4-20 mA, 2-wire Materials (Housing): Black plastic, Amodel AS-4133 HS-PPA
Operating, Storage, and Compensated Temperature Range: Materials in contact with media: SST 304L and Haynes 214 alloy
-40 F to +257 F (-40 C to 125 C) Approvals:
Electrical Termination: Cable (3 meter) CE: CE
Supply Voltage: 9.5Vdc to 30Vdc
Pneumatic Controls

Product Number Accuracy Pressure Ranges (psi) Burst Pressure Proof Pressure Connection Size
50035430-050 ± 0.50% FSS 50 psig 10X Working Pressure Range 3X Working Pressure Range 1/4 in.-18 NPT
50035430-150 ±0.25% FSS 150 psig 10X Working Pressure Range 3X Working Pressure Range 1/4 in.-18 NPT
50035430-300 ±0.25% FSS 300 psig 10X Working Pressure Range 3X Working Pressure Range 1/4 in.-18 NPT
50035430-500 ±0.25% FSS 500 psig 10X Working Pressure Range 3X Working Pressure Range 1/4 in. SAE female
Schrader
50035430-01K ±0.25% FSS 1000 psig 10X Working Pressure Range 2X Working Pressure Range 1/4 in. SAE female
Industrial Combustion

Schrader
Controls

70-6910 489
Temperature Sensors
C7031 Electronic Temperature Sensors

C7031D

C7031G
C7031J

Electronic temperature sensors used with DDC Systems. Maximum Ambient Temperature: 250 F (121 C)
• Solid state thermistor element provides accurate sensing of Shipping Temperature Range: -30 F to +160 F (-34 C to +71 C)
temperature changes.

Operating Temperature Range Insertion Length


Product Number Application Sensor Type (F) (C) (inch) (mm) Includes Used With
C7031B2005 Duct 1097 K ohm PTC @ -40 F to +250 F -40 C to +121 C 6 in. 152 mm — Excel 10, 50, 80, 100,
Discharge 77 F 500,T775 Series 2000
C7031D2003 Hot or chilled PT1000, 1097 40 F to 240 F 4 C to 116 C 5 in. 127 mm Well Excel 500, T775 Series
water ohms @ 77 F 2000
C7031G2006 Outside air 1715 @ 90F NTC -40 F to +120 F -40 C to +49 C — — — W7100 (outdoor reset)
temperature
C7031G2014 Outside air PT3000, 3484 -40 F to +120 F -40 C to +49 C — — — T7350
temperature ohms @ 77 F
C7031J2009 Duct PT1000, 1097 40 F to 180 F 4 C to 82 C 144 in. 3658 mm — Excel 500, T775 Series
Discharge ohms @ 77 F PTC 2000

490 customer.honeywell.com 70-6910


Temperature Sensors
Dimensions in inches (millimeters)

Controls
Home
3-5/8 (91) 2-1/4 (57)

1 (25) 3/4
(19)

5.75 ± 0.25

Indoor Air Quality


(146)

1/8 INCH NPSM


STRAIGHT FOAM PAD
THREADS

[8] 1/2 INCH


CONDUIT
KNOCKOUTS 1-59/64
(49)

Combustion Controls
Residential
SINGLE GANG 8-5/16
RACO COVER (211)

[2] 1/64 (5) X 5/8 (16)


5
MOUNTING HOLES 3-57/64 (127)
(99)

2-19/64
(58)

Hydronic Controls
1-5/32
(29)

7/8
M22132
(22)

2-3/32 (53)
4-3/16 (106) M27006
1-11/16
(43)

Controls
Water
1-11/16
1(25) 2-5/16 (43)
(59)
1-11/16
(43)

6-11/16 (170)

1-11/16 5 (127)
2-5/16

Building Automation
(43)
(59) 4-3/16 4
(107) (70)

1/4
1/2 NPSM (13) (6)

4-3/16 4
(107) (70)

Components
M22596

Commercial
4 THERMISTORS PLACED
ON A 12 FOOT (3.7M) WIRE. M22133

C7031 Accessories
Application: Temperature Sensor Part or Accessory
Pneumatic Controls

Product Number Description Application


32005960-001 Immersion well for C7031D Series 2 models only Temperature Sensor Part or Accessory

C7031 Replacement Parts


Application: Temperature Sensor Part or Accessory
Industrial Combustion

Product Number Description Application


Controls

32006523-001‘ Temperature probe for C7031D1062 Temperature Sensor Part or Accessory

70-6910 491
Temperature Sensors
C7041 20K ohm NTC Temperature Sensors

C7041K

C7041B,C
C7041F

C7041J

C7041D
C7041R

C7041P

The C7041 Electronic Temperature Sensors are designed to be Application: Duct Discharge
used with electronic controllers in domestic or commercial heating Sensor Type: 20 K ohm NTC @ 77 F
and cooling systems. Maximum Ambient Temperature: 302 F (150 C)
• The C7041 series of electronic temperature sensors are designed Operating Temperature Range: -40 F to +250 F (-40 C to +121 C)
for use with the Excel 10, Excel 15, or any controller requiring a 20K Shipping Temperature Range: -30 F to +160 F (-34 C to +71 C)
ohm NTC non-linearized sensor input. Used With: Excel 10, 50, 80, 100, 500
• Various models are available for sensing duct air temperature,
averaging air temperature, water temperature, outdoor air Accessories:
temperature, or water pipe temperature. 50001774-001 5 inch Stainless Steel Immersion Well for Use with
• All devices consist of a temperature sensitive element and leadwires C7041D2001
enclosed for protection from physical damage. 50001775-001 Immersion well adaptor, to adapt new C7041D2001 to fit
• Sensor element enclosures are made of various lengths and into old brass 32005960-001 well used with old C7031D1062 and
configurations for the specific applications. C7041D1003
• All devices have a wiring box housing to enclose the field wiring
connections. C7041F outdoor sensor design, made of aluminum and
stainless steel, is waterproof, and includes a sunshield.

Insertion Length
Product Number (inch) (mm) Application
C7041B2005 6 in. 152 mm Duct Discharge
C7041B2013 12 in. 305 mm Duct Discharge
C7041C2003 18 in. 457 mm Duct Discharge
C7041D2001 5 in. 127 mm Immersion sensor for hot or chilled water, purchase well 50001774-001 separately
C7041F2006 — — Outside air temperature

492 customer.honeywell.com 70-6910


Temperature Sensors

Controls
Insertion Length

Home
Product Number (inch) (mm) Application
C7041J2007 12 ft. 3.66 m Duct discharge air (averaging)
C7041K2005 — — Hot or chilled water (strap on)
C7041P2004 — — Temperature sensor
C7041R2000 12 ft. 3.66 m Duct discharge air (averaging)

Indoor Air Quality


C7041R2018 24 ft. 7.3 m Duct discharge air (averaging)
Dimensions in inches (millimeters)

C7031B: 5-11/16 (145)


1-13/16 C7041B: 11-5/8 (295)
1-11/16 (46) C7041C: 17-5/8 (448)
(43)
1-11/16 7/16 (12)

Combustion Controls
(43)

Residential
1-11/16
1(25) 2-5/16 (43)
(59)

4
(70)
1/8 NPSM (3)
4-3/16 4
(107) (70)

Hydronic Controls
1-11/16
(43)

4 THERMISTORS PLACED 3-7/8 (99)

Controls
ON A 12 FOOT (3.7M) WIRE. M22133

Water
15/16 2-5/16
(23) (59)

1-11/16
(43)

Building Automation
3/4 4-3/16
6-11/16 (170) (19) (107)

1-11/16 5 (127)
2-5/16 (43)
(59)

1/4
1/2 NPSM (13) (6) M27010

4-3/16 4
(107) (70) 3/16 (4)
5/16 1 (26)
1 (26) (8) 7/8 (22)

Components
Commercial
11/16
(18)
M22596

5/8 (16)
3/8 IN.-16 THREAD

SPACER SENSOR
Pneumatic Controls

M22821
Industrial Combustion
Controls

70-6910 493
Temperature Sensors
4-3/16 (107) 3-5/8 (91) 2-1/4 (57)

1-1/2 1 (25) 3/4


(38) (19)

2-5/16 1-1/2 9/16 (14)


(59) (38)

7-1/8 (182)
5 (127)
1
1-11/16 1-1/4
2-5/16 (43) (32)
(59)

8-5/16
(211)

4-3/16 4
(107) (70)
5
(127)

COPPER PLATE
1 MAXIMUM PIPE DIAMETER SHOWN. FOAM PAD
MINIMUM PIPE DIAMETER: 1-5/8 (41) 7/8
M22134 M22132
(22)

1-11/16
(43)

1
1-13/16 7/16 (12)
3-7/8 (99) (46)
1-11/16
15/16 2-5/16 (43)
(23) (59)

3/4 4-3/16 4
(19) (107) (70)
1/8 NPSM (3)

1 DEPENDING ON THE MODEL, THE ELEMENT LENGTH IS EITHER 12 FT (366 CM) OR 24 FT (732 CM).
M22818

C7041 Temperature Sensor Accessories


Product Number Description Used With
50001774-001 5 inch immersion well C7031D2003 and C7041D2001 onlyC7031D2000, C7041D2000 only
50001775-001 Immersion well adaptor C7031D2000, C7041D2000 series to thread into old 32005960-001

494 customer.honeywell.com 70-6910


Temperature Sensors
C7046 Discharge Air Temperature Sensors

Controls
Home
Air Temperature Sensors function as primary and/or secondary
sensors in electronic control systems.
• No settings or calibration required.
• Solid state components not affected by dust or dirt.
• Fast reacting.
• Rugged aluminum insertion probe.
• Mounts on duct or plenum surface with integral mounting flange, or

Indoor Air Quality


in a 2 x 4 in. junction box.

Application: Primary and/or secondary sensors in electronic control Mounting: Mounts on flat duct or plenum surface with integral mounting
systems flange or in a 2 in. x 4 in. (51 mm x 102 mm) junction box.
Maximum Ambient Temperature: 250 F (121 C) Includes: 6 in. leadwires
Operating Temperature Range: 40 F to 150 F (4 C to 66 C) Comments: Quick response time. Sensor probe diameter is 1/4 in. (6
Shipping Temperature Range: -30 F to +160 F (-34 C to +71 C) mm). 6 in. leadwires.

Combustion Controls
Residential
Insertion Length Dimensions, Approximate
Product Number Sensor Type (inch) (mm) (inch) (mm) Used With
C7046A1004 3K ohm @ 77 F NTC 8 in. 203 mm 1 in. high x 2 in. 25 mm high x 51 mm W973, W6210, W6215, W7210,
wide x 9 in. deep wide x 229 mm deep W7215, W7459, W7460
C7046A1038 3K ohm @ 77 F NTC 12 in. 305 mm 1 in. high x 2 in. 25 mm high x 51 mm W973, W6210, W6215, W7210,
wide x 13 in. deep wide x 330 mm deep W7215, W7459, W7460
C7046B1010 22.8 K ohm NTC @ 77 F 6 in. 152 mm 1 in. high x 2 in. 25 mm high x 51 mm W7080

Hydronic Controls
wide x 7 in. deep wide x 178 mm deep
C7046C1000 3K ohm @ 77 F NTC 8 in. 203 mm 1 in. high x 2 in. 25 mm high x 51 mm W973
wide x 9 in. deep wide x 229 mm deep
C7046D1008 1097 ohm @ 77 F PTC 8 in. 203 mm 1 in. high x 2 in. 25 mm high x 51 mm Excel 600, Excel 500, Excel 100,
wide x 9 in. deep wide x 229 mm deep Excel 80, and T775 Series 2000

C7100 Averaging Duct Temperature Sensors


Averaging Duct Temperature Sensors are used to sense

Controls
temperature in discharge duct.

Water
• Use to troubleshoot system operation.
• Platinum positive temperature coefficient sensor.
• Factory calibrated; no settings or field calibration required.

Application: Averaging Duct Temperature Sensors Maximum Ambient Temperature: 250 F (121 C)
Dimensions, Approximate: 1 13/16 in. high x 1 13/16 in. wide x 13 1/4

Building Automation
in. deep (46 mm high x 46 mm wide x 336 mm deep)

Operating Temperature
Range Insertion Length
Product Number Sensor Type (F) (C) (inch) (mm) Description Used With
C7100A1015 PT3000, 3484 ohms @ 40 F to 220 F 4 C to 104 C 13 in. 330 mm PT3000 Platinum Averaging W7100, W8900
77 F PTC Discharge Air Sensor
C7100B1013 22.8 K ohm @ 77 F 40 F to 150 F 4 C to 64 C 13 in. 330 mm 22.8 K ohm Averaging Air W7080
NTC Sensor

Components
Commercial
C7100C1003 PT3000, 3484 ohms @ 40 F to 220 F 4 C to 104 C 13 in. 330 mm PT3000 Platinum Averaging T775
25C PTC Discharge Air Sensor
C7100D1001 PT1000, 1097 ohms @ 40 F to 220 F 4 C to 104 C 13 in. 330 mm PT1000 Platinum Averaging Excel 500, T775
77 F PTC Discharge Air Sensor Series 2000

Pneumatic Controls
Industrial Combustion
Controls

70-6910 495
Temperature Sensors
C7130 Wall Mount Temperature Sensor
The C7130A,B Wall-Mount Air Temperature Sensors provide the
input required by the R7380J,L, W7100, W7600, W7620, and Excel
500 Control Systems to sense air temperature in indoor spaces.
• C7130A Wall-mount Temperature Sensor:
• Intended for use as an indoor air sensor with the R7380J,L
Indicating Controller, the W7100 Discharge Controller, the W7600
Direct Digital Controller, and the W7620 Direct Digital Controller.
• C7130B Wall-mount Temperature Sensor:
• Intended for use as an indoor air sensor with the Excel 500
Controller.

Application: Intended for monitoring or controlling temperature in Operating Temperature Range: -40 F to +100 F (-40 C to +38 C)
conjunction with an electronic control Shipping Temperature Range: -40 F to +150 F (-40 C to +65 C)
Dimensions, Approximate: 2 13/16 in. high x 4 5/8 in. wide (71.4mm Mounting: Wall mount
high x 118 mm wide) Used With: R7380J,L, W7100, W7600, W7620
Maximum Ambient Temperature: 150 F (66 C)

Product Number Sensor Type Used With


C7130A1001 PT3000, 3484 ohms @ 77 F PTC R7380J,L, W7100, W7600, W7620
C7130B1009 PT1000, 1097 ohms @ 77 F PTC Excel 500, T775 Series 2000

C7170 Immersion Sensor


Primary electronic temperature sensor for the R7380J,L, W7100
and W7505 load inputs for immersion, strap-on and duct mounting.
• Requires no setting or calibration.
• Sensor can be located up to 1195 ft. (340 m) from controller.
• Pigtail leads.

Application: Intended for monitoring or controlling temperature in Shipping Temperature Range: -40 F to +302 F (-40 C to +150 C)
conjunction with an electronic control Operating Humidity Range (% RH): 90% RH at 90 F, non-condensing
Dimensions, Approximate: 3/8 in. dia. x 2 5/8 in. long (10 mm dia. x Mounting: Immersion or strap-on discharge
66 mm long) Comments: Use immersion well 121371A copper or 121371E steel.
Operating Temperature Range: -40 F to +250 F (-40 C to +125 C) 24 in. pigtail leads

Insertion Length
Product Number Sensor Type (inch) (mm) Description Used With
C7170A1002 PT3000, 3484 ohms @ 77 F PTC 3 in. 76 mm PT 3000 Temperature Sensor with 24 in. leads R7380J,L, W7100, W7600,
W7620
C7170A1010 PT3000, 3484 ohms @ 77 F PTC 3 in. 76 mm PT 3000 Temperature Sensor with 180 in. R7380J,L, W7100, W7600,
leads W7620
C7170B1000 PT1000, 1097 ohms @ 77 F PTC 3 in. 76 mm PT 1000 Temperature Sensor Excel 500,
T775 Series 2000

496 customer.honeywell.com 70-6910


Temperature Sensors
C7750 Duct Probe

Controls
Home
Excel 10 Controller. The C7750A Sensor consists of a temperature
sensitive 20K ohm thermistor that is connected on a circuit board
to two linearizing resistors in series-parallel configuration.
• A primary and/or secondary sensor for use with electronic control
systems.
• Designed with an integral linearized 20K ohm thermistor.
• Operating range of 45 to 99 F (7.2 to 37.2 C).

Indoor Air Quality


• Intended for mounting on a flat duct or plenum surface or (for a
plenum-rated application) in a standard utility conduit box.
• Probe length of 6-1/2 in. (165 mm) and a nominal sensor resistance
of 8000 ohms at 77 F (25 C).
The C7750A is a direct wired temperature sensor that is used to • Rugged aluminum insertion probe.
sense discharge or return air in a duct that may be controlled by an
Application: Primary and/or secondary sensors in electronic control Shipping Temperature Range: -40 F to +150 F (-40 C to +65 C)
systems Operating Humidity Range (% RH): 5 to 95% RH, non-condensing

Combustion Controls
Dimensions, Approximate: 1 in. high x 2 in. wide x 7 in. deep (25 mm Mounting: Mounts on flat duct or plenum surface with integral mounting
high x 51 mm wide x 177 mm deep) flange or in a 2 in. x 4 in. (51 mm x 102 mm) junction box.

Residential
Operating Temperature Range: 45 F to 99 F (7 C to 37 C) Used With: XL10, W7751

Insertion Length
Product Number Sensor Type (inch) (mm) Description
C7750A3006 20 K ohm NTC linear 6 in. 152 mm 20 K ohm NTC linear Temperature Sensor, used with Excel 10, Series 1000 only

Hydronic Controls
C7770A Duct Probe
Direct wired temperature sensor used to sense discharge or return
air temperature in a duct controlled by an Excel 10 Series 2000
Controller.
• Primary and/or secondary sensor for use with electronic control
systems.
• Integral 20 K ohm non-linear NTC thermistor.
• Rugged aluminum insertion probe.

Controls
Water
Application: Primary and/or secondary sensors in electronic control Shipping Temperature Range: -40 F to +150 F (-40 C to +65 C)
systems Operating Humidity Range (% RH): 5 to 95% RH, non-condensing
Dimensions, Approximate: 1 in. high x 2 in. wide x 7 in. deep Mounting: Mounts on flat duct or plenum surface with integral mounting
(25 mm high x 51 mm wide x 177 mm deep) flange or in a 2 in. x 4 in. (51 mm x 102 mm) junction box.
Operating Temperature Range: 45 F to 99 F (7 C to 37 C) Used With: XL10, W7751

Building Automation
Insertion Length
Product Number Sensor Type (inch) (mm) Description Comments
C7770A1006 20 K ohm NTC non-linear 6 in. 152 mm 6 in. Duct Probe for Return Air 20 K ohm NTC non-linear —
Temperature Sensor
C7770A1040 20 K ohm NTC non-linear 6 in. 152 mm 6 in. Duct Probe for Return Air 20 K ohm NTC non-linear 6 foot plenum rated
Temperature Sensor cable

Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 497
Temperature Sensors
C7772 Flush Mount Sensors
The C7772 series of wallplate Temperature Sensors are designed
to be used with the Excel 5000 family and other Honeywell
controllers. The C7772 sensors provide a resistive output signal
proportional to sensed room or space temperature. The C7772 is
well suited for low profile wall mounted applications where
durability and tamper proof construction is desired, such as
schools, prisons, and institutions.
• Low profile when mounted on industry standard utility conduit box.
• Rugged, brushed stainless steel wallplate.
• Integral foam pad isolates wallplate sensor from conduit box.
• Insulated screw terminals ensure reliable field wiring connection.
• Models available with a variety of resistive temperature sensor
elements.

Dimensions in inches (millimeters) Application: Low profile wall mounted where durability and tamper
proof construction is desired
Dimensions, Approximate: 4 1/2 in. high x 2 3/4 in. wide (114 mm high
x 70 mm wide)
Operating Temperature Range: 45 F to 99 F (7 C to 37 C)
Shipping Temperature Range: -40 F to +150 F (-40 C to +65 C)
Operating Humidity Range (% RH): 5 to 95% RH, non-condensing
Mounting: Wall mount
Used With: Excel 5000 family
4-1/2 3-5/16
(114) (84)

2-3/4 (70) 5/16 (8)

M16295A

Product Number Sensor Type Description Comments


C7772A1004 20 K ohm NTC non- 20 K ohm NTC non-linear Wall Flush Mount —
linear Temperature Sensor without logo
C7772A1012 20 K ohm NTC non- 20 K ohm NTC non-linear Wall Flush Mount with Honeywell logo, looks very professional and
linear Temperature Sensor with Honeywell logo facilitates finding sensor after installation

T7022A Return Air Temperature Sensor


The T7022 Remote Temperature Sensor is a non-adjustable
thermistor sensor. Its primary use is with the T7300 Programmable
Commercial Thermostat (only in return air) to control heating or
cooling equipment.

Application: Remote Temperature Sensors for use with T7300 Operating Temperature Range: 60 F to 90 F (16 C to 32 C)
thermostats Used With: T7300, T7067B, W927
Dimensions, Approximate: 3/8 in. dia. x 2 3/4 in. long (10 mm dia. x
70 mm long)
A
Insertion Length
Product Number Sensor Type (inch) (mm) Application
T7022A1010 1420 ohms @ 75 F 2 3/4 in. 70 mm Remote Temperature Sensors for use with T7300 thermostats

498 customer.honeywell.com 70-6910


Temperature Sensors
T7047 Remote Temperature Sensors for use with T7300 Thermostats

Controls
Home
The T7047 Electronic Thermostats, Remote Space Sensors are
used with T7300 thermostats and W973 controller to provide
modulating space temperature control.
• T7047C is a 2-wire remote space sensor for applications requiring
remote setpoint adjustment.
• T7047G is a 2-wire remote space sensor used as one half of an
averaging sensor network.

Indoor Air Quality


• T7047C,G contain a carbon type negative temperature coefficient
(NTC) thermistor sensing element.
• T7047H is a thin-film, platinum 1K (at 0 C), positive temperature
coefficient (PTC) temperature sensor only and is for use with the
Excel 80/100/500/600 Controllers.
• Locking cover.

Application: Used in Series 70 control systems to provide modulating


space temperature control

Combustion Controls
Operating Temperature Range: 40 F to 110 F (4 C to 43 C)
Mounting: Mounts on wall or 2 x 4 inch vertical outlet box

Residential
Product Number Sensor Type Color Comments Used With
T7047C2007 1420 ohms @ 75 F Taupe Series 2000 styling T7300/Q7300
T7047C2015 1420 ohms @ 75 F Premier White® Series 2000 styling T7300/Q7300
T7047G1000 710 ohm @ 75F Beige Series 1000 styling, for averaging only T7300/Q7300, S963B, T7067B, T7080B
T7047G1018 710 ohm @ 75F Premier White® Series 1000 styling, for averaging only Premier White T7300, Light Gray Q7300

Hydronic Controls
T7047G2008 710 ohm @ 75F Taupe Series 2000 styling, for averaging only. T7300/Q7300
T7047G2016 710 ohm @ 75F Premier White® Series 2000 styling, for averaging only. T7300/Q7300
Dimensions in inches (millimeters)

1-13/16 (46)

Controls
3-1/4

Water
(83)

4-5/8
(117)

3-13/16
(97)

Building Automation
7/8 (22) 3/8 2-7/8 (73)
1-1/16 (27) (10) 3-5/8 (92)
M17720

T7047 Accessories

Components
Commercial
Product Number Description Application
190389A Cover assembly for T7047A,B, series 1000 styling Temperature Sensor Part or Accessory
Pneumatic Controls
Industrial Combustion
Controls

70-6910 499
Temperature Sensors
T7147 Remote Temperature Sensors for use with T7300 Thermostats
For use with T7300/Q7300 Thermostat system to provide space
temperature sensing, and switch initiation and indication of
overrides from remote location.
• Factory-calibrated negative temperature coefficient (NTC) thermistor
sensing element.
• Mount on wall or 2 x 4 in. vertical outlet box.
• Locking cover.
• Override button.
• Warmer/cooler buttons on some models.
• 710 ohm models are for use with certain multiple sensor
configurations.
• See T7300 product literature for details.

Dimensions in inches (millimeters)


Application: Provides space temperature sensing, switch initiation, and
indication of overrides from a remote location
1-13/16 (46) Dimensions, Approximate: 4 5/8 in. high x 3 5/8 in. wide x 1 5/8 in.
deep (117 mm high x 92 mm wide x 41 mm deep)
Operating Temperature Range: 40 F to 110 F (4 C to 43 C)
Shipping Temperature Range: -30 F to +150 F (-34 C to +66 C)
3-1/4 Operating Humidity Range (% RH): 5 to 90% RH, non-condensing
(83) Mounting: Mounts on wall or 2 x 4 inch vertical outlet box
Used With: T7300/Q7300
4-5/8
(117)

3-13/16
(97)

7/8 (22) 3/8 2-7/8 (73)


1-1/16 (27) (10) 3-5/8 (92)
M17720

Product Number Sensor Type Color Comments


T7147A2000 1420 ohms @ 75 F Taupe Series 2000 styling with override button
T7147A2018 1420 ohms @ 75 F Taupe Series 2000 styling with override button, warmer and cooler buttons
T7147G2015 710 ohm @ 75F Taupe Series 2000 styling, with override button, for averaging only.
T7147G2023 710 ohm @ 75F Taupe Series 2000 styling, with override button, warmer and cooler buttons, for averaging only.

500 customer.honeywell.com 70-6910


Temperature Sensors
T7560 Digital Wall Modules

Controls
Home
The T7560 Digital Wall Module is a direct wired wall module for use
with Excel 600, 500, 100, and Excel 10 Series 2000 controllers.
Includes setpoint wheel, override buttons, and LCD display for
temperature, setpoint, fan status, and/or humidity
• 2 models configurable to cover all applications.
• T7560B has Humidity sensor.
• Intuitive and easy to operate.

Indoor Air Quality


Combustion Controls
Residential
Dimensions in inches (millimeters)
Application: Networked Sensor
Sensor Type: 20 K ohm NTC
Operating Temperature Range: 32 F to 104 F (0 C to 40 C)
Shipping Temperature Range: -40 F to +140 F (-40 C to +60 C)
4-1/8 Operating Humidity Range (% RH): 5 to 90% RH, non-condensing
(104)
Approvals:

Hydronic Controls
CE: Approved
N.E.C. Class II
Underwriters Laboratories, Inc. Listed: per Standard 916

3-15/16 (99) 1-3/16 (30)


M23229

Controls
Setpoint

Water
Temperature
Range
Product Number (F) (C) Color Comments Includes Used With
T7560A1018 55 F to 12 C to — — Setpoint Wheel, Unoccupied/Occupied Excel 10, 100, 500, 600
85 F 30 C override, and LCD display for temperature, Controllers; Excel 600, 500,
setpoint and fan status 100 and Excel 10, 15 Series

Building Automation
Controllers
T7560A1042 55 F to 12 C to White with Same as T7560A1018 Setpoint Wheel, Unoccupied/Occupied Excel 10, 100, 500, 600
85 F 30 C white knob except with white knob override, and LCD display for temperature, Controllers
and push buttons setpoint and fan status
T7560B1016 55 F to 12 C to — — Humidity sensor, Setpoint Wheel, Unoccupied/ Excel 10, 100, 500, 600
85 F 30 C Occupied override, and LCD display for Controllers
temperature, setpoint, fan status and humidity
T7560B1032 55 F to 12 C to White with Same as T7560B1016 Humidity sensor, Setpoint Wheel, Unoccupied/ Excel 10, 100, 500, 600
85 F 30 C white knob except with white knob Occupied override, and LCD display for Controllers
and push buttons temperature, setpoint, fan status and humidity

Components
Commercial
T7560LONJACK — — — Lon Jack for T7560 — T7560A, B

Pneumatic Controls
Industrial Combustion
Controls

70-6910 501
Temperature Sensors
T775 Series 2000 Sensors
The T775 temperature sensors are 1097 Ohm sensors for use with
the T775 Series 2000 electronic standalone controller in
commercial heating and cooling applications.
• Use the T775-SENS-OAT to measure outside air temperature.
• Some typical applications for the 50021579-001 and T775-
SENSWT/WR sensors include:
• Monitoring return air temperatures
• Monitoring discharge air temperatures
• Monitoring mixed air temperatures
• All sensors:
• Fast response time and highly accurate
• 1/2 in. (6.35 mm) stainless steel probe with a thermally conductive
epoxy
• 1,097 Ohms PTC at 77ÞF (25C)
• The 50021579-001 is a standard temperature sensor for indoor
applications
• The T775-SENS-WR is a water resistant sensor with 5 ft leads
• The T775-SENS-WT is a water tight sensor with 6 ft leads
• The T775-SENS-OAT is for sensing outdoor air temperature and is
housed in a weatherproof case for outdoor use (knockouts allow for
1/2 in. conduit connection)
• Two year warranty

Application: For indoor use in applications such as monitoring return


air, discharge air, and mixed air temperatures
Used With: T775 Series 2000

Operating Temperature Range


Product Number Application Sensor Type (F) (C) Description
50021579-001 For indoor use in applications such as 1097 ohm @ 77 F -40 F to 270 F -40 C to 132 C Standard Temperature Sensor
monitoring return air, discharge air, and mixed PTC for the T775 Series 2000
air temperatures
T775-SENS-OAT Outside air temperature PT1000, 1097 -40 F to 158 F -40 C to 70 C 1097 ohm Outdoor Air
ohms @ 77 F PTC Temperature Sensor
T775-SENS-STRAP Hot or chilled water (strap on) PT1000, 1097 -40 F to +250 F -40 C to +121 C Strap-on Sensor for Hot or
ohms @ 77 F PTC Chilled Water
T775-SENS-WR For use in applications such as monitoring PT1000, 1097 -40 F to 270 F -40 C to 132 C Water-resistant Sensor for
return air, discharge air, and mixed air ohms @ 77 F PTC T775 Series 2000.
temperatures
T775-SENS-WT For use in applications such as monitoring PT1000, 1097 -40 F to 270 F -40 C to 132 C Water-tight Sensor for T775
return air, discharge air, and mixed air ohms @ 77 F PTC Series 2000
temperatures

502 customer.honeywell.com 70-6910


Temperature Sensors
Dimensions in inches (millimeters)

Controls
Home
1/2 ± 1/8 1/2 ± 1/8 3/8 ± 1/8
(13 ± 3) (13 ± 3) WHITE (10 ± 3)
RED
RED

2 ± 1/16

Indoor Air Quality


1-1/2 ± 1/16 1-1/2 ± 1/16
(38 ± 2) (38 ± 2) (51 ± 2)

50021579-001 T775-SENS-WR
-80C to 200C -80C to 200C
0641 0641

BLACK T775-SENS-WT

HEATSHRINK -40 to 270F


0708

Combustion Controls
9 ± 1/8 5±2 6±3

Residential
(227 ± 3) (127 ± 51) (153 ± 76)

3 CONDUCTOR
TEFLON CABLE

Hydronic Controls
3/8 (10) DUAL WALL
HEAT SHRINK 1-1/2 ± 3/32
(38 ± 2)

1/4 O.D. 1/4 O.D. 1/4 O.D.


(6) (6) (6) 2 (3/16 DIA.)
2 ± 1/64 2 ± 1/64 2 ± 1/64 (51) (5 DIA.)
(51 ± 1) (51 ± 1) (51 ± 1) STAINLESS STEEL PROBE

Controls
Water
M23937 M23935 M23936

4-3/16 (107)
3-5/8 (91) 2-1/4 (57)

Building Automation
1-1/2
(38) 1 (25) 3/4
(19)

2-5/16 1-1/2 9/16 (14)


(59) (38)

7-1/8 (182)
5 (127)
1

Components
Commercial
1-11/16 1-1/4
2-5/16 (43) (32)
(59)

8-5/16
(211)

4-3/16 4
Pneumatic Controls

(107) (70) 5
(127)

COPPER PLATE
1 MAXIMUM PIPE DIAMETER SHOWN. 7/8
FOAM PAD M22132
Industrial Combustion

(22)
MINIMUM PIPE DIAMETER: 1-5/8 (41) M22134
Controls

70-6910 503
Temperature Sensors
T7750 Wall Modules
Temperature sensors for use with Excel 10 Series 1000 Controllers.
The T7750 Wall Modules provide the following additional
combination of options to the customer: analog setpoint input and
for models used with Excel 10 Controllers, override (bypass) digital
input contact, LED status indicator and network access jack.
• Integral linearized 20K ohm NTC thermistor.
• Vertical Mounting.
• Models available with setpoint adjustment.
• Models available with occupied/unoccupied override.
• For use only as replacement of existing T7750's.
• Not for new installations.
• All new Honeywell controllers now use T7770 Wall Modules.

Application: Wall Modules


T7750A T7750B T7750C T7750D
Dimensions, Approximate: 5 1/32 in. high x 3 5/32 in. wide x 1 19/32
in. deep (128 mm high x 80 mm wide x 41 mm deep)
Setpoint Temperature Range: 55 F to 85 F (12 C to 30 C)
Operating Temperature Range: 45 F to 99 F (7 C to 37 C)
Mounting: Wall mount

Setpoint Temperature
Range
Product Number (F) (C) Comments Used With
T7750A1000 55 F to 85 F 12 C to 30 C — W7751
T7750B1008 55 F to 85 F 12 C to 30 C Has optional setpoint W7751 or XL600, 500, 100, 80, 20
T7750C1006 55 F to 85 F 12 C to 30 C Has optional setpoint, override, and override LED W7751
T7750D1004 55 F to 85 F 12 C to 30 C Has override, and override LED W7751

T7771 Wall Module


The T7771A Remote Temperature Sensors are direct wired wall
modules for use with the Honeywell T7350 Commercial
Programmable Thermostat. The T7771A has a space temperature
sensor, LED push button setpoint adjustment, and override with
LED.
• Push button setpoint adjustment with LED indicators.
• Occupied/unoccupied override (bypass) with LED.
• LONWORKS® bus jack.
• Operating range 45 to 99 F (7 to 37 C).

Application: Remote Room Temperature Sensor for use with T7350 Mounting: Mounted on a standard 2 x 4 inch junction box or on a 60
thermostat mm diameter junction box.
Dimensions, Approximate: 5 1/32 in. high x 3 5/32 in. wide x 1 in. Comments: Can be configured to output 10K ohms for use in multiple
deep (128 mm high x 80 mm wide x 25 mm deep) sensor averaging with T7770A.
Operating Temperature Range: 45 F to 99 F (7 C to 37 C) Used With: T7350
Shipping Temperature Range: -40 F to +150 F (-40 C to +65 C)
Approvals:
Operating Humidity Range (% RH): 5 to 95% RH, non-condensing N.E.C. Class II

Setpoint Temperature Range


Product Number Sensor Type (F) (C) Color Network Jack
T7771A1005 20 K ohm NTC non-linear offset ± 3F offset ± 1.67C White LonWorks Bus

504 customer.honeywell.com 70-6910


Temperature Sensors
TR20 Series Wall Modules

Controls
Home
The TR21, TR22, TR23, and TR24 are a family of direct wired wall
modules for use with Honeywell Excel 600, 500, 100, and 80
controllers; Excel 10 W7750, W7751A, W7752, and W7753
controllers; W7761 Controller; and Spyder Unitary Controllers. All
models have a space temperature sensor.
• Models available with user selectable setpoint adjustment dials in
Fahrenheit, Celsius and Relative Scales

Indoor Air Quality


• Models available with occupied/unoccupied override (bypass) with
LED
• Models available with 3-position (auto/0/1) or 5-position (auto/0/1/2/3
speed) fan switch
• LONWORKS network jack on all models except the TR21 and TR21-
A models
• Models available with on board humidity sensor, humidity output: 0-
10Vdc, 0-5 Vdc, 4-20ma selectable

Combustion Controls
TR21, TR24 TR22, TR23

Residential
Application: Networked Sensor Used With: Spyder, Excel 600, 500, 100, 80 and Excel 10, 15 Series
Operating Temperature Range: 45 F to 99 F (7 C to 37 C) Controllers
Shipping Temperature Range: -40 F to +150 F (-40 C to +65 C) Approvals:
Operating Humidity Range (% RH): 5 to 95% RH, non-condensing CE: Approved
Color: White Federal Communications Commission: FCC Part 15, Class B
Mounting: Mounted on a standard 2 x 4 inch junction box or on a 60 Underwriters Laboratories, Inc. UL94 plastic enclosure

Hydronic Controls
mm diameter junction box.
Comments: Also used with the T7350 and TB8220 Thermostats

Model Number Sensor Type Selectable


Setpoint
Adjustment
Honeywell Replaces 20K ohm 55° to 85°F, Override
Wall Module Honeywell Sensor Element NTC 13° to 30°C, Button LON Fan
Model Model Type Temp Humidity Or (- to +) with LED Jack Switching Comments
TR21 T7770A1006 20K ohms non-linear 3

Controls
Water
TR21-A T7770A3002 10K ohms non-linear 3
for averaging only
TR21-H N/A 3 3
TR21-J T7770A2004 3 3
TR22 T7770B1004 3 3 3
T7770B1020

Building Automation
T7770B1046
TR23 T7770C1002 3 3 3 3
T7770C1028
T7770C1044
TR23-KL N/A 3 3 3 3 Bulk pack of 20
Setpoint knob not included
20K ohms non-linear
TR23-H N/A 3 3 3 3 3
TR23-H-KL N/A 3 3 3 3 3 Bulk pack of 20
Setpoint knob not included
TR23-N T7770C1051 3 3 3 3 No Honeywell logo

Components
Commercial
TR24 T7770D1000 3 3 3
TR22-F5 N/A 3 3 3 5 position
TR23-F3 T7770E1023 3 3 3 3 3 position
TR23-F5 T7770F1005 3 3 3 3 5 position Pneumatic Controls

Replacement Parts for the TR20 Series Wall Modules


Product Number Color Description Comments Used With
KNOB-C White Celsius Scale Knobs, (13 to 30C) sold in packs of 20 TR20 Series Wall Modules
KNOB-F White Fahrenheit Scale Knobs (55F to 85F) sold in packs of 20 TR20 Series Wall Modules
KNOB-O White Relative Scale Knobs (- to +) sold in packs of 20 TR20 Series Wall Modules
Industrial Combustion
Controls

70-6910 505
Temperature Sensors
TR20 Series Wireless Wall Sensor Kits
The WRECVR receiver and TR21-WS, TR23-WS, TR21-WK, and
TR23-WK sensors are a family of wireless wall modules and
receivers. All models report space temperature; TR23 models
come with setpoint adjustment and override.
• Wall module to Receiver (point to point) wireless kits can replace any
standard wired sensor
• Wireless Kits (wall module and receiver) are pre bound at the factory
for quick installation
• Signal Strength LED built into the wall module
• Low battery indication
• Optional dip switches available to bind any wall module to any
receiver
• Approximate 5 year battery life with AA Alkaline (included), 7.5 year
with Lithium
• Locking screw discourages tampering and battery theft

Dimensions, Approximate: Radio Frequency: 2.4 GHz (IEEE Std 802.15.4-2003 compliant)
Sensor: 4 11/16 in. high x 3 in. wide x 7/8 in. deep Receiver Voltage: 20-30 Vac/dc, 50/60 Hz; 24 Vac typical
Receiver: 5 1/2 in. high x 3 13/64 in. wide x 2 13/64 in. deep Open Range: 3000 feet
(Sensor: 119 mm high x 77 mm wide x 22 mm deep Typical Range: 100 feet
Receiver: 140 mm high x 81 mm wide x 56 mm deep) Comments: not compatible with TB7220, TB8220,TB line voltage
Operating Temperature Range: Sensor: 45 F to 99 F (7 C to 37 C) thermostats, XL15s, W7762, W7763
Receiver: -40 to +150 F (-40 to + 65.5 C) Used With: Spyder, Excel 10 W7750, W7751, W7752, W7753, T7350,
Shipping Temperature Range: -40 F to +150 F (-40 to + 65.5 C) T7351, TB8575, WEBs-AX™ I/O Module
Temperature Sensor Accuracy: ± 1 F across 53.6 F to 86 F Approvals:
((± 0.5 C) across 12 C to 30 C) Federal Communications Commission: FCC Part 15
Operating Humidity Range (% RH): 5 to 95% RH, non-condensing Underwriters Laboratories, Inc. UL94 plastic enclosure
Battery Life: 7.5 years with two AA Lithium Batteries; Receiver: UL94-5VA
5 years with two AA Alkaline batteries (included)

Setpoint Temperature
Range
Product Number Description (F) (C) Additional Comments Includes
TR21-WK Wireless sensor kit, ships with both sensor — — — TR21-WS and WRECVR
and receiver
TR21-WKU Wireless sensor kit, ships with both sensor — — no Honeywell logo TR21-WSU and WRECVRU
and receiver
TR23-WK Wireless sensor kit, ships with both sensor 55 F to 85 F 13 C to 30 C — TR23-WS and WRECVR
and receiver
TR23-WKU Wireless sensor kit, ships with both sensor 55 F to 85 F 13 C to 30 C no Honeywell logo TR23-WSU and RECVRU
and receiver

506 customer.honeywell.com 70-6910


Temperature Sensors
TR20 Series Wireless Wall Sensors

Controls
Home
TR21-WS and TR23-WS sensors are a family of wireless wall
modules. All models report space temperature; TR23 models come
with setpoint adjustment and override.
• Wall module to Receiver (point to point) wireless kits can replace any
standard wired sensor
• Wireless Kits (wall module and receiver) are pre bound at the factory
for quick installation

Indoor Air Quality


• Signal Strength LED built into the wall module
• Low battery indication
• Optional dip switches available to bind any wall module to any
receiver
• Approximate 5 year battery life with AA Alkaline (included), 7.5 year
with Lithium
• Locking screw discourages tampering and battery theft

TR21 TR23

Combustion Controls
Residential
Dimensions, Approximate: 4 11/16 in. high x 3 in. wide x 7/8 in. deep Radio Frequency: 2.4 GHz (IEEE Std 802.15.4-2003 compliant)
(119 mm high x 77 mm wide x 22 mm deep) Open Range: 3000 feet
Operating Temperature Range: 45 F to 99 F (7 C to 37 C) Typical Range: 100 feet
Shipping Temperature Range: -40 F to +150 F (-40 to + 65.5 C) Comments: not compatible with TB7220, TB8220,TB line voltage
Temperature Sensor Accuracy: ± 1 F across 53.6 F to 86 F thermostats, XL15s, W7762, W7763
((± 0.5 C) across 12 C to 30 C) Used With: Spyder, Excel 10 W7750, W7751, W7752, W7753, T7350,
Operating Humidity Range (% RH): 5 to 95% RH, non-condensing T7351, TB8575, WEBs-AX™ I/O Module
Mounting: Wall mount

Hydronic Controls
Approvals:
Color: White Federal Communications Commission: FCC Part 15
Battery Life: 7.5 years with two AA Lithium Batteries; 5 years with two Underwriters Laboratories, Inc. UL94 plastic enclosure
AA Alkaline batteries (included)

Setpoint Temperature
Range
Product Number Description (F) (C) Includes
TR21-WS TR21 wireless temperature sensor — — —
TR21-WSU TR21 Wireless Temp Sensor without Honeywell logo — — —

Controls
Water
TR23-WS TR23 Wireless temperature sensor with Setpoint 55 F to 85 F 13 C to 30 C Selectable Setpoint dials in Fahrenheit, Celsius,
(F/C/Relative) and override button and Relative (- to +), and Override Button
TR23-WSU TR23 Wireless temperature sensor, with Setpoint 55 F to 85 F 13 C to 30 C Selectable Setpoint dials in Fahrenheit, Celsius,
(F/C/Relative) and override button, no Honeywell logo and Relative (- to +), and Override Button

TR20 Series Wireless Wall Modules

Building Automation
The WRECVR receiver and TR21-WS, TR23-WS, TR21-WK, and
TR23-WK sensors are a family of wireless wall modules and
receivers.
• Wall module to Receiver (point to point) wireless kits can replace any
standard wired sensor
• Wireless Kits (wall module and receiver) are pre bound at the factory
for quick installation
• Signal Strength LED built into the wall module
• Low battery indication
• Optional dip switches available to bind any wall module to any

Components
Commercial
receiver

Application: Receiver
Dimensions, Approximate: 5 1/2 in. high x 3 13/64 in. wide x 2 13/64
in. deep (140 mm high x 81 mm wide x 56 mm deep)
Operating Temperature Range: -40 to +150 F (-40 to + 65.5 C)
Shipping Temperature Range: -40 F to +150 F (-40 to + 65.5 C)
Operating Humidity Range (% RH): 5 to 95% RH, non-condensing
Pneumatic Controls

Radio Frequency: 2.4 GHz (IEEE Std 802.15.4-2003 compliant)


Receiver Voltage: 20-30 Vac/dc, 50/60 Hz; 24 Vac typical
Open Range: 3000 feet
Typical Range: 100 feet
Approvals:
Federal Communications Commission: FCC Part 15
Underwriters Laboratories, Inc. UL94-5VA

Product Number Description Comments Used With


Industrial Combustion

WRECVR Receiver used with wireless temperature sensors — TR21-WS, TR23-WS


Controls

WRECVRU Receiver used with wireless temperature sensors no Honeywell logo TR21-WSU, TR23-WSU

70-6910 507
Temperature Sensors
Zio LCD Wall Modules
All models have a space-temperature sensor, network bus jack,
and an LCD with three softkeys and two Up/Down adjustment keys.
The TR70-H model includes an onboard humidity sensor.
• Ability to control user access to controller parameters.
• Parameter access can be customized by using the Tridium Niagara
Workbench tool.
• Programmable for: Home screen options, tenant access, contractor
access, access to controller parameters, setpoint, override, fan, and
other parameters.
• Supplied with eight pre-programmed configurations (e.g. VAV with
balancing) in the wall module configuration tool.
• Ability to access and adjust most parameters in the programmable
controller (except Scheduling).
• Ability to balance the VAV system from the wall module.
• Home screen can display one to three of any of the following
parameters: Temperature Setpoint, Room Temperature, Room
Humidity, Outdoor Humidity, Outdoor Temperature, and Time, or one
of virtually any parameter in the controller.
• Network bus jack.
• Simple 2-wire terminal connection to the programmable controller
The TR70 and TR70-H are 2-wire, non-polarity sensitive, Sylk™ bus and an optional 2-wire terminal connection for the network. All
communicating wall modules for use with Spyder™ programmable connections are polarity insensitive.
controllers which are compatible with the Sylk bus. • Retention of user configuration, including setpoints after a power
outage.
Application: Temperature sensor Color: White
Dimensions, Approximate: 3 5/16 in. wide x 4 5/8 in. high x 15/16 in. Comments: Configurable with Niagara Workbench
deep (84 mm wide x 117 mm high x 24 mm deep) Used With: Spyder Sylk Enhanced
Operating Temperature Range: 30 F to 110 F (-1 C to 43 C) Approvals:
Shipping Temperature Range: -40 F to +150 F (-40 C to 65.5 C) Canadian Standards Association: CE: Approved
Operating Humidity Range (% RH): 5 to 95% RH, non-condensing Federal Communications Commission: FCC Part 15
Network Communications: Sylk Bus and Network Jack Underwriters Laboratories, Inc. UL94-HB plastic enclosure
Mounting: Vertical Mount
Switch Positions (Fan): Configurable

Temperature Sensor Accuracy Setpoint Temperature Range


Humidity Sensor
Product Number (F) (C) Accuracy (F) (C)
TR70 ±0.36 F at 77 F ±0.2 C at 25 C — Default range is 55 F to 85 F; Default range is 10 C to 35 C;
configurable for other ranges configurable for other ranges
TR70-H ±0.36 F at 77 F ±0.2 C at 25 C ±5% RH from 20% to 80% Default range is 55 F to 85 F; Default range is 10 C to 35 C;
RH configurable for other ranges configurable for other ranges

508 customer.honeywell.com 70-6910


Submeters
Class 100 Single Phase kWh Meter

Controls
Home
The Honeywell Class 100 kWh meters are fully electronic, low-cost
meters for monitoring electrical usage in multi-family, commercial
and industrial applications. Monitor anything from a single lighting
circuit to an entire building. Ideal for both new and retrofitted
facilities. Can be used for tenant monitoring and billing.
• UL/CUL Listed
• Direct-read 8-digit LCD displays accumulative kWh and ’real time’

Indoor Air Quality


kW load.
• 0-2 volt split-core current sensors allow safer installation without
power interruption.
• Certified to ANSI C12.1 and C12.16.
• Parallel up to three (3) sets of current sensors for cumulative
reading.
• Meter can be used in the following configurations: 1-Phase, 2-Wire;
2-Phase, 3-Wire
• Industrial-grade JIC steel enclosure with padlocking hasp and

Combustion Controls
mounting flanges for indoor installations with 1-1/16 in. knockout(3/4
in. conduit) on bottom of enclosure.

Residential
• Maintains reading in the event of power failure.
• Non-volatile Memory.
• Meters can be placed up to 2,000 feet away from an electric panel
(by extending current sensor leads).
Dimension Diagrams: See page 512 Display: Yes
Frequency (Hz): 50 Hz; 60 Hz
Application: The Honeywell Class 100 kWh meters are fully electronic, Number of Phases: 1
meters for monitoring electrical usage in commercial and industrial

Hydronic Controls
Operating Temperature Range: -4 F to 122 F (-20 C to 50 C)
applications. Operating Humidity Range (% RH): 0-95% non-condensing
Dimensions, Approximate: 7-1/2 in. high x 7 in. wide x 3-1/4 in. deep
(191 mm high x 178 mm wide x 83 mm deep) Approvals:
Output: Pulse Canadian Standards Association: Recognized
Accuracy: ±1% from 1% to 100% of rated load Underwriters Laboratories, Inc. Listed

Product Number Current Sensor Rating (A) Input Voltage Input Voltage Configuration
SUB2120-100 100A 120V 2 Wire
SUB2120-200 200A 120V 2 Wire

Controls
Water
SUB2120-25 25A 120V 2 Wire
SUB2120-50 50A 120V 2 Wire
SUB3208-100 100A 208-240; V120V 3 Wire
SUB3208-200 200A 208-240V; 120V 3 Wire
SUB3208-25 25A 208-240V; 120V 3 Wire

Building Automation
SUB3208-50 50A 208-240V; 120V 3 Wire

Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 509
Submeters
Class 200 Three Phase kWh Meter
The Honeywell Class 200 kWh meters are fully electronic, low cost
meters for monitoring electrical usage in multifamily, commercial
and industrial applications.
• UL/CUL Listed.
• Direct-read 8-digit LCD displays accumulative kWh and ’real time’
kW load.
• 0-2 volt output split-core current sensors allow for quick and safe
installation without power interruption.
• Certified to ANSI C12.1 and C12.16.
• Parallel up to three (3) sets of current sensors for cumulative
reading.
• Meter can be used on the following configurations:3-Phase, 4-Wire;
3-Phase, 3-Wire; 2-Phase, 3-Wire.
• Industrial-grade JIC steel enclosure with padlocking hasp and
mounting flanges for indoor installations with 1-1/16 in. knockout(3/4
in. conduit) on bottom of enclosure.
• Maintains reading in the event of power failure.
• Non-volatile Memory.
• Meters can be placed up to 2,000 feet away from an electric panel.
Dimension Diagrams: See page 512 Frequency (Hz): 50 Hz; 60 Hz
Number of Phases: 3
Application: The Honeywell Class 200 kWh meters are fully electronic, Operating Temperature Range: -4 F to 122 F (-20 C to 50 C)
meters for monitoring electrical usage in commercial and industrial Operating Humidity Range (% RH): 0-95% non-condensing
applications.
Output: Pulse Approvals:
Accuracy: ±1% from 1% to 100% of rated load Canadian Standards Association: Recognized
Display: Yes Underwriters Laboratories, Inc. Listed

Product Number Current Sensor Rating (A) Input Voltage Input Voltage Configuration
SUB208-100 100A 120V/208-240V 3-4 Wire
SUB208-1600 1600A 120V/208-240V 3-4 Wire
SUB208-200 200A 120V/208-240V 3-4 Wire
SUB208-3200 3200A 120V/208-240V 3-4 Wire
SUB208-400 400A 120V/208-240V 3-4 Wire
SUB208-800 800A 120V/208-240V 3-4 Wire
SUB480-100 100A 277V; 480V 3-4 Wire
SUB480-1600 1600A 277V; 480V 3-4 Wire
SUB480-200 200A 277V; 480V 3-4 Wire
SUB480-3200 3200A 277V; 480V 3-4 Wire
SUB480-400 400A 277V; 480V 3-4 Wire
SUB480-800 800A 277V; 480V 3-4 Wire

510 customer.honeywell.com 70-6910


Submeters
Class 500 Advanced kWh/Demand Meter

Controls
Home
The Class 500 Meter is a 3-element meter with communications.
The device is used to monitor electric power usage of individual
loads after the utility meter and store kW and kVAR data for
automatic meter reading. Installation must only be performed by
qualified personnel and in accordance with these instructions and
all applicable local and national electrical codes.
• Direct-read 8-digit LCD display of cumulative kWh.

Indoor Air Quality


• Modbus Option: (Modbus RTU, Modbus TCP, BACnet)
• Provides 40 Modbus data registers.
• 0-2 volt output split-core current sensors.
• Remote mounting of current sensors up to 500 feet from meter.
• Current sensor installation diagnostic indicator.
• Communication Options:RS485 (Modbus RTU), Ethernet (Modbus
TCP, BACnet)
• Modbus version supports two external inputs from gas, water, etc.
meters. (Dry contact, 10 Hz max. input.)

Combustion Controls
• Available in standard JIC Industrial-grade steel enclosure.
• UL Listed; meets or exceeds ANSI C12 national accuracy standards.

Residential
• Optional power failure contact for alarming.

Dimension Diagrams: See page 512 Number of Phases: 3


Operating Temperature Range: -4 F to 122 F (-20 C to 50 C)
Application: The Class 500 Advanced KWH/Demand Meter with Full Operating Humidity Range (% RH): 0-95% non-condensing
Data Stream are fully electronic, meters for monitoring electrical usage
in commercial and industrial applications. Approvals:

Hydronic Controls
Accuracy: ±1% from 1% to 100% of rated load Canadian Standards Association: Recognized
Display: Yes Underwriters Laboratories, Inc. Listed
Frequency (Hz): 50 Hz; 60 Hz

Product Number Protocol Current Sensor Rating (A) Input Voltage Input Voltage Configuration Output
SUB208-100C Modbus RTU 100A 120V; 208-240V 3-4 Wire RS-485
SUB208-1600C Modbus RTU 1600A 120V; 208-240V 3-4 Wire RS-485
SUB208-200C Modbus RTU 200A 120V; 208-240V 3-4 Wire RS-485
SUB208-3200C Modbus RTU 3200A 120V; 208-240V 3-4 Wire RS-485

Controls
Water
SUB208-400C Modbus RTU 400A 120V; 208-240V 3-4 Wire RS-485
SUB208-800C Modbus RTU 800A 120V; 208-240V 3-4 Wire RS-485
SUB480-100C Modbus RTU 100A 277V; 480V 3-4 Wire RS-485
SUB480-1600C Modbus RTU 1600A 277V; 480V 3-4 Wire RS-485
SUB480-200C Modbus RTU 200A 277V; 480V 3-4 Wire RS-485

Building Automation
SUB480-3200C Modbus RTU 3200A 277V; 480V 3-4 Wire RS-485
SUB480-400C Modbus RTU 400A 277V; 480V 3-4 Wire RS-485
SUB480-800C Modbus RTU 800A 277V; 480V 3-4 Wire RS-485
SUBAC208-100C BACnet 100A 120V; 208-240V 3-4 Wire Ethernet
SUBAC208-1600C BACnet 1600A 120V; 208-240V 3-4 Wire Ethernet
SUBAC208-200C BACnet 200A 120V; 208-240V 3-4 Wire Ethernet
SUBAC208-3200C BACnet 3200A 120V; 208-240V 3-4 Wire Ethernet
SUBAC208-400C BACnet 400A 120V; 208-240V 3-4 Wire Ethernet

Components
Commercial
SUBAC208-800C BACnet 800A 120V; 208-240V 3-4 Wire Ethernet
SUBAC480-100C BACnet 100A 277V; 480V 3-4 Wire Ethernet
SUBAC480-1600C BACnet 1600A 277V; 480V 3-4 Wire Ethernet
SUBAC480-200C BACnet 200A 277V; 480V 3-4 Wire Ethernet
SUBAC480-3200C BACnet 3200A 277V; 480V 3-4 Wire Ethernet
Pneumatic Controls

SUBAC480-400C BACnet 400A 277V; 480V 3-4 Wire Ethernet


SUBAC480-800C BACnet 800A 277V; 480V 3-4 Wire Ethernet
SUBM208-100C Modbus TCP 100A 120V; 208-240V 3-4 Wire Ethernet
SUBM208-1600C Modbus TCP 1600A 120V; 208-240V 3-4 Wire Ethernet
SUBM208-200C Modbus TCP 200A 120V; 208-240V 3-4 Wire Ethernet
SUBM208-3200C Modbus TCP 3200A 120V; 208-240V 3-4 Wire Ethernet
SUBM208-400C Modbus TCP 400A 120V; 208-240V 3-4 Wire Ethernet
Industrial Combustion

SUBM208-800C Modbus TCP 800A 120V; 208-240V 3-4 Wire Ethernet


Controls

SUBM480-100C Modbus TCP 100A 277V; 480V 3-4 Wire Ethernet


SUBM480-1600C Modbus TCP 1600A 277V; 480V 3-4 Wire Ethernet

70-6910 511
Submeters
Product Number Protocol Current Sensor Rating (A) Input Voltage Input Voltage Configuration Output
SUBM480-200C Modbus TCP 200A 277V; 480V 3-4 Wire Ethernet
SUBM480-3200C Modbus TCP 3200A 277V; 480V 3-4 Wire Ethernet
SUBM480-400C Modbus TCP 400A 277V; 480V 3-4 Wire Ethernet
SUBM480-800C Modbus TCP 800A 277V; 480V 3-4 Wire Ethernet

Dimensions for Meters and Current Sensors


Dimensions in inches (millimeters) for 800 and 1600 Amp current sensor dimensions
Class 100, Class 200 and Class 500 Meters
1-1/4
6-3/32 (155) (32)

2-3/8
(60)

7 (178) 3-1/4 (83)


4-19/64 5-3/4
(109) (146)

7-1/2
(191)

M29270

3200 Amp current sensor dimensions

M29258 1-1/4
7-3/4 (197) (32)
25-200 Amp current sensor dimensions

3-3/4 (95)
29/32
(23) 1-19/64 (33)

1-3/8
9-3/32
(35) 2-3/4 5-3/8 (137)
(70) (231)

7-7/8
(200)

M29268

400 Amp current sensor dimensions

3-3/4 (95) 1-19/64 (33)


M29271

1-3/8 1-1/2
(35) (38)
4-1/4
(108)

29/32 1-3/16
(23) (30)

M29269

512 customer.honeywell.com 70-6910


Submeters
SXB35/SXB36 Networked Power Meters (Modbus® RTU)

Controls
Home
Honeywell’s innovative three-phase networked (Modbus RTU)
power meters combine power metering electronics and high
accuracy industrial grade CTs in a single package.There are two
application-specific platforms to choose from.
The SXB35 Meters are ideal for submetering applications where
only kW and kWh are required. The SXB36 Enhanced Data Stream

Indoor Air Quality


meters output 26 energy variables including kW, kWh, volts, amps,
and power factor, making them ideal for power monitoring and
diagnostics.
• Monitor energy parameters (kW, kWh, kVAR, PF, Amps, Volts) at up
to 63 locations on a single RS-485 network–greatly reduces wiring
time and cost.
• Fast split-core installation eliminates the need to remove
conductors–saves time and labor.
• Precision metering electronics and current transformers in a single

Combustion Controls
package reduces the number
• of installed components, meaning huge labor savings.

Residential
• Smart electronics eliminate CT orientation concerns–resulting in
fast, trouble-free installation.
• Certified to ANSI C12.16.

Dimensions in inches (millimeters)

F
MEDIUM
SMALL 400/800 AMP
F 100/300 AMP

Hydronic Controls
A = 4-29/32 (125)
A = 3-51/64 (96) B B = 2-29/32 (73)
B B = 1-1/2 (38) C = 2-1/2 (62)
C = 1-19/64 (31) D = 1-3/32 (29)
D = 1-3/32 (29) C E = 5-13/64 (132)
C E = 4 (100)
D F = 5-29/32 (151)
D F = 4-51/64 (121)
E E
A A
M29225 M29226

Output: RS-485
F LARGE Accuracy: ±1% total system accuracy, (10% to 100% of CT rating)

Controls
800/1600/2400 AMP Display: No

Water
A = 4-29/32 (125) Frequency (Hz): 50 Hz; 60 Hz
B B = 5-1/2 (139) Operating Temperature Range: 32 F to 140 F (0 C to 60 C)
C = 2-1/2 (62)
D = 1-3/32 (29)
Operating Humidity Range (% RH): 0-95% non-condensing
E = 7-29/32 (201) Protocol: Modbus RTU
C
F = 6 (151)
D Approvals:
E Canadian Standards Association: Recognized

Building Automation
Underwriters Laboratories, Inc. Listed
A
M29227

Product Number CT Size Current Sensor Rating (A) Input Voltage Number of Phases
SXB35-100 Small 100A 208V - 480V 1 to 3
SXB35-300 Small 300A 208V - 480V 1 to 3
SXB35-400 Medium 400A 208V - 480V 1 to 3
SXB35-800-3 Medium 800A 208V - 480V 1 to 3

Components
Commercial
SXB35-800-4 Large 800A 208V - 480V 1 to 3
SXB35-1600 Large 1600A 208V - 480V 1 to 3
SXB35-2400 Large 2400A 208V - 480V 1 to 3
SXB36-100 Small 100A 208V - 480V 1 to 3
SXB36-300 Small 300A 208V - 480V 1 to 3
SXB36-400 Medium 400A 208V - 480V 1 to 3
Pneumatic Controls

SXB36-800-3 Medium 800A 208V - 480V 1 to 3


SXB36-800-4 Large 800A 208V - 480V 1 to 3
SXB36-1600 Large 1600A 208V - 480V 1 to 3
SXB36-2400 Large 2400A 208V - 480V 1 to 3
Industrial Combustion
Controls

70-6910 513
Submeters
SXB40/SXB50 Self Contained Split-Core kW/kWh Transducers
The Honeywell SXB40/SXB50 Series kW (real power)/kWh
(consumption) transducers combine processing electronics and
industrial grade CTs in an easy-to install split-core package. These
devices continuously measure voltage and current values for the
monitored conductors and update calculations to provide highly
accurate true RMS power readings. Models designed for balanced
loads include one CT only, while models for unbalanced loads
have three CTs.
• Fast split-core installation eliminates the need to remove
conductors–perfect for retrofits.
• Precision meter electronics and current transformers in a single
package reduces the number of installed components, resulting in
huge labor savings.
• Smart electronics eliminate the need to be concerned with CT
orientation, providing fast, trouble-free installation.
• Certified to ANSI C12.16

Dimensions in inches (millimeters)

MEDIUM
SMALL F
400/800 AMP
F 100/300 AMP
A = 4-29/32 (125)
A = 3-51/64 (96)
B B = 2-29/32 (73)
B B = 1-13/64 (30)
C = 2-1/2 (62)
C = 1-19/64 (31)
D = 1-13/64 (30)
D = 1-13/64 (30) C
C E = 5-13/64 (132)
E = 4 (100)
D F = 5-29/32 (151)
D F = 4-51/64 (121)
E E
A A
M29198 M29199

Application: Ideal for monitoring electrical power in commercial and


LARGE industrial facilities
F
800/1600/2400 AMP Accuracy: ±1% total system accuracy, (10% to 100% of CT rating)
A = 4-29/32 (125) Display: No
B B = 5-1/2 (139) Frequency (Hz): 50 Hz; 60 Hz
C = 2-1/2 (62) Operating Temperature Range: 32 F to 140 F (0 C to 60 C)
D = 1-13/64 (30)
E = 7-29/32 (201) Operating Humidity Range (% RH): 0-95% non-condensing
C
F = 6 (151)
D Approvals:
E Canadian Standards Association: Recognized
Underwriters Laboratories, Inc. Listed
A
M29200

Product Number CT Size Current Sensor Rating (A) Input Voltage Output Number of Phases
SXB42-100 Small 100A 480V 4-20mA 1
SXB42-300 Small 300A 480V 4-20mA 1
SXB42-400 Medium 400A 480V 4-20mA 1
SXB42-800-3 Medium 800A 480V 4-20mA 1
SXB42-800-4 Large 800A 480V 4-20mA 1
SXB42-1600-4 Large 1600A 480V 4-20mA 1
SXB42-2400 Large 2400A 480V 4-20mA 1
SXB43-100 Small 100A 208V; 240V 4-20mA 3
SXB43-300 Small 300A 208V; 240V 4-20mA 3
SXB43-400 Medium 400A 208V; 240V 4-20mA 3
SXB43-1600 Large 1600A 208V; 240V 4-20mA 3
SXB43-2400 Large 2400A 208V; 240V 4-20mA 3
SXB43-800-3 Medium 800A 208V; 240V 4-20mA 3
SXB43-800-4 Large 800A 208V; 240V 4-20mA 3
SXB44-100 Small 100A 480V 4-20mA 3
SXB44-300 Small 300A 480V 4-20mA 3
SXB44-400 Medium 400A 480V 4-20mA 3
SXB44-800-3 Medium 800A 480V 4-20mA 3
SXB44-800-4 Large 800A 480V 4-20mA 3
SXB44-1600 Large 1600A 480V 4-20mA 3

514 customer.honeywell.com 70-6910


Submeters

Controls
Product Number CT Size Current Sensor Rating (A) Input Voltage Output Number of Phases

Home
SXB44-2400 Large 2400A 480V 4-20mA 3
SXB51-100 Small 100A 208V; 240V Pulse 1
SXB51-300 Small 300A 208V; 240V Pulse 1
SXB51-400 Medium 400A 208V; 240V Pulse 1
SXB51-800-3 Medium 800A 208V; 240V Pulse 1

Indoor Air Quality


SXB51-800-4 Large 800A 208V; 240V Pulse 1
SXB51-1600 Large 1600A 208V; 240V Pulse 1
SXB51-2400 Large 2400A 208V; 240V Pulse 1
SXB53-100 Small 100A 208V; 240V Pulse 3
SXB53-300 Small 300A 208V; 240V Pulse 3
SXB53-400 Medium 400A 208V; 240V Pulse 3

Combustion Controls
SXB53-800-3 Medium 800A 208V; 240V Pulse 3

Residential
SXB53-800-4 Large 800A 208V; 240V Pulse 3
SXB53-1600 Large 1600A 208V; 240V Pulse 3
SXB53-2400 Large 2400A 208V; 240V Pulse 3

SXBC-1, SXBC-5 Integration Nodes

Hydronic Controls
To answer the needs for open-protocol standards and cost- Dimensions in inches (millimeters)
effective energy information, Honeywell offers the SXBC Series of
LonTalk Integration Nodes. Transducers can be connected to 4-19/64 (108) WIRE
LonWorks networks through the SXBC devices. Couple the CL OPENING
simplified installation of our Modbus power meters to the flexible 1-13/64 (30)
SXBC platform and realize installation savings of up to 70% when
compared to ’standard’ power transducers.
• Easy Integration to Honeywell networks
• Pre-configured to pass points acquired by Honeywell transducers to SXBC Series
LonTalk® Integration Node

a Lon controller
• Easy cost-effective connectivity to LonWorks systems...makes open 4-19/64 C
L
(108)
connectivity possible

Controls
Water
C
• Flexible mounting and wiring options save time and money L 2-13/64
1-13/64 (54)
(30)

1-19/32
(39) M29415

Building Automation
Product Number Description
SXBC-1 SXB36 to LonTalk® integration node
SXBC-5 SXB35 to LonTalk® integration node

Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 515
Fan Coil Thermostats
T4039 Fan Coil Thermostat
Control line voltage valves of a fan coil unit in cooling, manual or
automatic changeover heating-cooling systems.
• Directly operate one or two valves.
• Positive deadband separates heating and cooling circuits in
automatic models.
• Includes allen wrench for cover and mounting screws.

Dimensions, Approximate: 4 5/8 in. high x 4 15/16 in. wide x 1 5/16 in. Display: No
deep. (118 mm high x 125 mm wide x 33 mm deep) Includes: Allen wrench for cover and mounting screws
Mounting: 4 in. square outlet box or 2-ganged outlet box
Approvals:
Electrical Ratings: Canadian Standards Association: Certified
Fan Switch: 120 Vac: 5.5 AFL, 33.0 ALR; 240 Vac: 2.75 AFL, 16.5 Underwriters Laboratories, Inc. File No. E34436, Vol 2, dated 3-19-
ALR; 277 Vac: 2.4 AFL, 14.4 ALR 73; Guide No. XAPX
Thermostat (Valve load): 120 Vac: 0.32 AFL, 1.0 A ALR; 240 Vac: 0.16
AFL, 0.50 ALR; 277 Vac: 0.14 AFL, 0.43 ALR Accessories:
Voltage: 120 to 277 Vac TG511A1000 Medium Universal Thermostat Guard with clear cover and
Frequency: 50 Hz; 60 Hz base, and opaque wallplate Fits T822, T834, T8034, T841, T874 with
Operating Humidity Range (% RH): 5 to 95% RH, non-condensing Q674, WR1F46, and others
Setting Temperature Range: 55 F to 95 F, marked COOL-WARM TG511D1004 Medium Universal Thermostat Guard with Beige painted
(13 C to 35 C, marked COOL-WARM) steel cover, opaque ring base and wallplate Fits T822, T834, T8034,
T841, T874 with Q674, and others

Differential Temperature Switch Position


Product Number Application (F) (C) System Fan Changeover Color
T4039B1008 Fan coil, Approximately 2 F at midscale Approximately 1 C at midscale ON-OFF HI-MED- — Tan
cooling only LO
T4039J1026 4 pipe fan coil, The differential from make of The differential from make of OFF-HI-LO, — Remote changeover Tan
automatic one contact to make of the one contact to make of the Off breaks switch is required to
heat-cool opposite contact is 7 F opposite contact is 4 C cooling and separate circuits in
changeover maximum with a positive maximum with a positive fan circuits manual changeover
deadspot. deadspot. heating-cooling
models.
T4039M1004 4 pipe fan coil, The differential from make of The differential from make of ON-OFF HI-MED- Automatic Tan
automatic one contact to make of the one contact to make of the LO
heat-cool opposite contact is 7 F opposite contact is 4 C
changeover maximum with a positive maximum with a positive
deadspot. deadspot.
T4039M1103 4 pipe fan coil, The differential from make of The differential from make of ON-OFF HI-MED- Automatic Premier
automatic one contact to make of the one contact to make of the LO White®
heat-cool opposite contact is 7 F opposite contact is 4 C
changeover maximum with a positive maximum with a positive
deadspot. deadspot.
T4039S1016 4 pipe fan coil, The differential from make of The differential from make of HEAT-OFF- HI-MED- Manual Tan
manual one contact to make of the one contact to make of the COOL LO
heat-cool opposite contact is 7 F opposite contact is 4 C
changeover maximum with a positive maximum with a positive
deadspot. deadspot.
T4039S1040 4 pipe fan coil, The differential from make of The differential from make of HEAT-OFF- HI-MED- Manual Tan
manual one contact to make of the one contact to make of the COOL LO
heat-cool opposite contact is 7 F opposite contact is 4 C
changeover maximum with a positive maximum with a positive
deadspot. deadspot.

516 customer.honeywell.com 70-6910


Fan Coil Thermostats
T6069 Fan Coil Thermostat

Controls
Home
T6069 thermostats control line voltage valves and/or blower
motors on fan coil units in manual changeover heating/cooling
systems. The thermostats feature a single System and Fan speed
switch.
• Thermostat, system and fan control switches combined in one
deluxe-styled unit.
• Available in classic gold or contemporary white styling. Language-

Indoor Air Quality


free graphic symbols.
• Manual three-speed fan control on most models.
• Suitable for single or double gang electrical boxes.
• Operates one or two valves.
• Has cycled or constant fan control.

Combustion Controls
Residential
Dimensions, Approximate: 4 5/8 in. high x 4 1/2 in. wide x 1 7/8 in. Display: No thermometer
deep. + 5/8 in projection into junction box
Approvals:
(119 mm high x 114 mm wide x 47 mm deep + 15 mm projection into Canadian Standards Association: File No. LR1322
junction box) Underwriters Laboratories, Inc. File No. E47434
Mounting: Mounts on 2 in. x 4 in. (50mm x 75 mm) single or double-

Hydronic Controls
ganged vertically-oriented outlet box. Accessories:
Electrical Ratings: TG511A1000 Medium Universal Thermostat Guard with clear cover and
8.0 AFL/48 ALR/13A resistive @ 120 Vac base, and opaque wallplate Fits T822, T834, T8034, T841, T874 with
4.4 AFL/26.4 ALR/7.5A resistive @208 Vac Q674, WR1F46, and others
4.0 AFL/24 ALR/6.5A resistive @240 Vac TG511D1004 Medium Universal Thermostat Guard with Beige painted
3.3 AFL/19.8 ALR 5.5A resistive @277 Vac steel cover, opaque ring base and wallplate Fits T822, T834, T8034,
Voltage: 120 to 277 Vac T841, T874 with Q674, and others
Frequency: 50 Hz; 60 Hz

Setting

Controls
Temperature Differential

Water
Range Temperature Switch Position
Product Number Application (F) (C) (F) (C) System Fan Changeover Color
T6069A4010 2 pipe fan coil, manual heat-cool 44 F to — 2F — HEAT-OFF- HI-MED- Manual Tan
changeover, constant or cycled fan 86 F COOL LO
T6069B4000 4 pipe fan coil, manual heat-cool — 7 C to 28 — 1C HEAT-OFF- HI-MED- Manual Premier

Building Automation
changeover, constant fan C COOL LO White®
T6069B4018 4 pipe fan coil, manual heat-cool 44 F to — 2F — HEAT-OFF- HI-MED- Manual Tan
changeover, constant fan 86 F COOL LO
T6069C4016 4 pipe fan coil, manual heat-cool 44 F to — 2F — HEAT-OFF- HI-MED- Manual Tan
changeover, cycled fan 86 F COOL LO
T6069D4014 2 pipe fan coil, seasonal auto 44 F to — 2F — ON-AUTO- HI-MED- Seasonal Auto with Tan
changeover, constant or cycled fan 86 F OFF LO External Aquastat®
Controller

Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 517
Fan Coil Thermostats
T6169 Fan Coil Thermostat
The T6169 thermostats control line voltage valves and/or blower
motors on fan coil units in manual or automatic changeover,
cooling, heating or cooling/heating systems. The thermostats
feature a single fan and/or system manual switches.
• Combines thermostat, single system and/or fan control switch in one
deluxe-styled unit.
• Three speed manual FAN control on some models.
• Fan can be wired for continuous (ON) or cycled (AUTO) operation.
• System switch OFF position breaks heating/cooling and fan circuits.
• Color-coded leadwire connections.
• Available in classic gold or Premier White® styling.
• Language-free graphic symbols.
• Suitable for single or double gang electrical boxes.

Dimensions, Approximate: 4 5/8 in. high x 4 1/2 in. wide x 1 7/8 in. Approvals:
deep. + 5/8 in projection into junction box Canadian Standards Association: File No. LR1322
(133 mm high x 114 mm wide x 47 mm deep + 15 mm projection into Underwriters Laboratories, Inc. File No. E47434
junction box)
Mounting: Mounts on 2 in. x 4 in. (50mm x 75 mm) single or double-
Accessories:
TG511A1000 Medium Universal Thermostat Guard with clear cover and
ganged vertically-oriented outlet box.
base, and opaque wallplate Fits T822, T834, T8034, T841, T874 with
Electrical Ratings: 8.0 AFL/48 ALR/13A resistive @ 120 Vac
Q674, WR1F46, and others
4.4 AFL/26.4 ALR/7.5A resistive @208 Vac
TG511D1004 Medium Universal Thermostat Guard with Beige painted
4.0 AFL/24 ALR/6.5A resistive @240 Vac
steel cover, opaque ring base and wallplate Fits T822, T834, T8034,
3.3 AFL/19.8 ALR 5.5A resistive @277 Vac
T841, T874 with Q674, and others
Frequency: 50 Hz; 60 Hz
Display: No thermometer

Setting
Temperature Differential
Range Temperature Switch Position
Product Number Application (F) (C) (F) (C) Voltage System Fan Changeover Color
T6169A4001 2 pipe fan coil, seasonal auto — 7 C to — 1C 120 to 277 — HI-OFF- Seasonal Auto with Premier
changeover, constant or cycled 28 C Vac MED-LO External Aquastat® White®
fan Controller
T6169A4019 2 pipe fan coil, seasonal auto 44 F to — 2F — 120 to 277 — HI-OFF- Seasonal Auto with Tan
changeover, constant or cycled 86 F Vac MED-LO External Aquastat®
fan Controller
T6169B4017 4 pipe fan coil, manual heat-cool 44 F to — 2F — 120 Vac; HEAT- — Manual Tan
changeover, no fan switching 86 F 277 Vac OFF-
COOL
T6169C4015 2 pipe fan coil, manual or auto 44 F to — 2F — 120 Vac; Auto-Off — Automatic; Manual Tan
changeover 86 F 277 Vac

Fan Coil Thermostat Accessories


Product Number Description Used With
137905E Faceplate for T4039M beige model. —
50033847-001 Adapter plate for mounting TB6575/TB8575 series fan coil thermostats to vertical, single or double-gang —
junction box
PS20 20 K ohm Pipe sensor TB6575, TB8575
W6380B1005 Fan Coil Unit Relay Control Center for 24 Vac Fan Coil Thermostats —
W6380B1005 Fan Coil Unit Relay Control Center for 24 Vac Fan Coil Thermostats —

Replacement Parts
Product Number Description Used With
190389AD Cover assembly for T4039 with Thermometer T4039
272735T Tan wallplate for covering old thermostat marks. To be used with T6069 and T6169 thermostats T6069, T6169

518 customer.honeywell.com 70-6910


Fan Coil Thermostats
TB6575; TB8575 Digital Fan-Coil Thermostat

Controls
Home
• Digital display of ambient temperature, setpoint, mode icons when
cooling or heating relays operate, when energy savings mode is
active, and fan status.
• Four buttons allow manual control of system operation, fan speed,
and temperature setpoint adjustment.
• VersaSpeed™ Fan Ramp Algorithm automatically adjusts Low,
Medium, High fan speed.

Indoor Air Quality


• Optional freeze protection feature that turns on heat, if necessary.
• Activity sensing algorithm sets back thermostat to economy mode.
• Auto fan rest option sets back fan to auto mode.
• Energy savings mode -- external energy savings input from dry
contact such as time switch, occupancy sensor, or hotel cardkey
overrides comfort setpoint with selectable setback heating or cooling
setpoints.
• Energy savings input configurable as a normally open or normally
The TB6575A, TB6575B, and TB8575A are a family of Digital Fan- closed dry contact.

Combustion Controls
Coil thermostats for residential and commercial applications. They • Proportional plus integral (P+I) control algorithm for precision
are great for use in hotels, condos, and school classrooms. They temperature regulation.

Residential
provide line voltage and low voltage on/off control for various fan- • Selectable C or F.
coil units. The three models provide control of 2 or 4 pipe fan-coil • Adjustable deadband, in auto changeover mode, for heat and cool
units, 120, 240, or 24 Vac, and manual or automatic heat/cool control.
changeover. The fan can also be controlled from the thermostat, • Adjustable maximum heating and minimum cooling setpoint limits.
which offers three fan speeds (Low, Med, High) and Auto. Valves • Installer setup mode allows changes of operating parameters.
and auxiliary electric heaters can be controlled using a relay or • EEPROM permanently retains user settings, including setpoints,
contactor system switch controlled by the thermostat. during power loss (no batteries required).
• Simple, intuitive user interface and ease of installation. • Capability to display temperature sensor failure for easier

Hydronic Controls
• Attractive modern styling ideal for hotels and condos. troubleshooting.
• Optional remote temperature sensor and remote pipe sensor.
Dimensions, Approximate: 3 13/16 in. high x 5 13/16 in. wide x 1 1/8 Accessories:
in. deep (97 mm high x 148 mm wide x 29 mm deep) 50033847-001 Adapter plate for mounting TB6575/TB8575 series fan
Mounting: Direct mounting on horizontal 2 x 4 in. (50mm x 75 mm) coil thermostats to vertical, single or double-gang junction box
junction box. Mounts on vertical 2 x 4 in. or 4 x 4 in junction box with WSK-24 Wireless Occupancy Solution
optional wall plate (50033847-001). PS20 20 K ohm Pipe sensor
Color: Premier White® TR21 20 K ohm NTC non-linear Temperature Wall Module
Display: LCD TR21-A 10 K ohm NTC non-linear Temperature Wall Module (for
Changeover: Manual/Auto averaging only)

Controls
Electrical Ratings: 120 Vac, Fan Rating: 6.0 A, Relay Rating: 1.0 A; C7041B2005 20K ohm NTC Temperature Sensor with 6 in. insertion

Water
240 Vac, Fan Rating: 3.0 A, Relay Rating: 1.0 A C7041B2013 20K ohm NTC Temperature Sensor with 12 in. insertion
Frequency: 50 Hz; 60 Hz C7041C2003 20K ohm NTC Temperature Sensor with 18 in. insertion
Operating Humidity Range (% RH): 5 to 95% RH, non-condensing C7041P2004 20K ohm NTC Stainless Steel Button Sensor, 11/16 in.
Approvals: dia.
Canadian Standards Association: Certified C7770A1006 6 in. Duct Probe for Return Air 20 K ohm NTC non-linear
Underwriters Laboratories, Inc. Temperature Sensor

Building Automation
Meets the same requirements as UL-873 C7772A1004 20 K ohm NTC non-linear Wall Flush Mount Temperature
Sensor without logo
C7772A1012 20 K ohm NTC non-linear Wall Flush Mount Temperature
Sensor with Honeywell logo

Setting Temperature
Range Switch Position
Product Number Application (F) (C) System Fan Description Voltage
TB6575A1000 2 or 4 pipe fan coil, Heat/ 50 F to 90 F 10 C to 30 C OFF-HEAT- HI-MED- 3-Speed Fan Coil Thermostat; 2 or 120 Vac
Cool manual/auto COOL- LOW-AUTO- 4 pipe Manual/Auto Heat/Cool (±10%) or

Components
Commercial
changeover, 3-speed fan, AUTO OFF changeover, 3 speed fan, Supply 240 Vac
120 - 240 Vac voltage: 120/240 Vac 50/60 Hz (± 10%)
TB6575B1000 2 pipe fan coil, Heat/Cool 50 F to 90 F 10 C to 30 C OFF-HEAT- HI-MED- 3-Speed Fan Coil Thermostat; 2 120 Vac
manual/auto changeover, COOL- LOW-AUTO- pipe Manual/Auto Heat/Cool (±10%) or
3-speed fan, 120 - 240 Vac AUTO OFF changeover, 3 speed fan, Supply 240 Vac
voltage: 120/240 Vac 50/60 Hz (±10%)
TB8575A1000 2 or 4 pipe fan coil, Heat/ 50 F to 90 F 10 C to 30 C OFF-HEAT- HI-MED- 3-Speed Fan Coil Thermostat; 2 or 20 to 30 Vac
Cool manual/auto COOL- LOW-AUTO- 4 pipe Manual/Auto Heat or Cool
Pneumatic Controls

changeover, 3-speed fan, AUTO OFF changeover, 3 speed fan, Supply


24 Vac voltage: 24 Vac 50/60 Hz
Industrial Combustion
Controls

70-6910 519
Wireless Occupancy Solutions
Wireless Occupancy Solution
The WSK-24 Wireless Occupancy Solution automatically controls
HVAC equipment by determining when a room is occupied. The
WSK-24 uses the combination of an occupancy sensor and a door
switch to provide optimal control. The WSK-24 is packaged in a kit
that includes a 24V dry contact receiver, a wireless PIR (passive
infrared receiver) occupancy sensor with mounting kit, a wireless
door sensor with mounting kit, and a wiring harness.
The receiver can be wired into any thermostat or controller that
supports the connection of a remote setback device. The receiver
communicates wirelessly to a PIR occupancy sensor, a door
sensor, and an optional 2nd door/window sensor. After the receiver
determines that the room is unoccupied, it closes a dry contact
switch. After the thermostat or controller recognizes the contact
closure, it places the thermostat in economy setback mode, which
provides energy savings for when the room is unoccupied.
• Wireless system provides quick and easy installation
• Pre-configured door sensor and occupancy sensor
• Guest comfort is maintained by never turning off HVAC equipment
when someone is in the room ñ even if they are sleeping
• Fuse protection
• Long battery life
• Low battery indication
• Receiver memory retained after power loss
• Optional sliding door/window sensor can be easily
• added

Side view of PIR detection pattern


Dimensions, Approximate:
M Door Sensor: 2-19/64 in. high x 1-13/32 in. wide x 19/32 in. deep
2
(58 mm high x 36 mm wide x 15 mm deep)
Receiver: 3-13/32 in. high x 3-19/32 in. wide x 1-13/64 in. deep
1
(86 mm high x 91 mm wide x 31 mm deep)
PIR Sensor: 3-29/32 in. high x 2-51/64 in. wide x 1-3/32 in. deep
(100 mm high x 71 mm wide x 28 mm deep)
C3 A 8 M Power Supply:
1 2 4 B 5 6 7
LENGTH 3 ~ 8 M M29142
Receiver: 24 Vac/Vdc at 50/60 Hz;
Standby power consumption 15 mA; Channel 1 relay output, N.O.
Top view of PIR detection pattern Door Sensor: Two CR2032 lithium batteries
PIR Sensor: Three AAA E92 1.5V alkaline batteries
70° Battery Life: Door Sensor: Two years (under normal usage)
60° PIR Sensor: One year (under normal usage)
50° Used With: TB6575, TB8575; TB7100;
40° T7350/T7351 (requires R8222 switching relay)
30° Approvals:
Federal Communications Commission: FCC Part 15, Class B
20°

10°

10°

20°

30°

40°
50°
60°
70° M29143

Operating Temperature Range


Product Number Operating Frequency Open Range Typical Range PIR Detection Pattern (F) (C)
WSK-24 Door Sensor: 433.92 MHz; With antenna With antenna Angle: 140 degrees; PIR Sensor: PIR Sensor:
Receiver: 433.92 MHz exposed: 200 ft; exposed: 100 ft; Length: 3 to 8 meters -4 F to 104 F; -20 C to 40 C;
With antenna coiled With antenna coiled when mounted 2 meters Door Sensor: Door Sensor:
inside receiver: 50 ft inside receiver: 40 ft above the floor -4 F to 140 F; -20 C to 60 C;
Receiver: Receiver:
-5 F to 140 F -21 C to 60 C

520 customer.honeywell.com 70-6910


Wireless Occupancy Solutions
Receiver dimensions in inches (millimeters) PIR Motion Sensor dimensions in inches (millimeters)

Controls
Home
3-13/32

Indoor Air Quality


(86)

3-29/32
(100)

3-19/32
(91)

Combustion Controls
1-13/64

Residential
(31)

M29498 2-51/64 1-3/32


(71) (28)
Door Sensor dimensions in inches (millimeters) M29497

Hydronic Controls
2-19/64
(58)

Controls
Water
1-13/32 19/32
(36) (15)

Building Automation
M29501

Wireless Occupancy Solution Accessories


Battery Life: Door Sensor: Two years (under normal usage)

Operating
Product Number Description Frequency Open Range Typical Range Used With
50037735-001 Optional Sliding 433.92 MHz With antenna exposed: 200 ft; With antenna exposed: 100 ft; WSK-24

Components
Commercial
Door/Window With antenna coiled inside receiver: 50 ft With antenna coiled inside receiver: 40 ft
Sensor

Wireless Occupancy Solution Replacement Parts


Operating Temperature Range
Pneumatic Controls

Product Number Description Operating Frequency (F) (C) Used With


50037736-001 Wireless PIR Occupancy Sensor 433.92 MHz -4 F to 104 F -20 C to 40 C WSK-24
50037737-001 Wireless Receiver 433.92 MHz -5 F to 140 F -21 C to 60 C WSK-24
Industrial Combustion
Controls

70-6910 521
Line Voltage Thermostats
T451; T651 Medium Duty Line Voltage Thermostat
Light Duty Line Voltage Thermostats control line voltage valves,
motors, contractors, electric heat, elements, duct furnaces, and fan
coil units in heating/cooling systems.
• Automatic cooling and heating anticipation.
• Mount on standard vertical or horizontal outlet box.

Dimensions in inches (millimeters) Electrical Ratings:


22 A @ 120 - 240 Vac Resistive
1-15/32 9/16 19 A @ 277 Vac Resistive.
(35) (14) 9.8 FLA/58.8 ALR @ 120 Vac
5.6 FLA/33.6 ALR @ 208 Vac
60 70 4.9 FLA/29.4 ALR @240 Vac
50 80
4.2 FLA/25.2 ALR @277 Vac
Electrical Connections: Flylead
40 90 Voltage: 120 Vac - 227 Vac
4-17/32 Frequency: 50 Hz; 60 Hz
3-9/32
(114) (83)
Sensor Element: Vapor filled dual diaphragm
F 1-3/4 COOL HEAT COM Color: Champagne gold face-plate with beige cover
(45)
40 50 60 70 80 90
Approvals:
Canadian Standards Association: CSA Certified, File No. LR1322
15/16 Underwriters Laboratories, Inc. Listed: File No. E47434, Guide No.
(24) XAPX.

2-13/16 (70) 1-1/8 1-1/8 Accessories:


17/32
(22) (37) (14) TG511A1000 Medium Universal Thermostat Guard with clear cover and
1-13/16
base, and opaque wallplate Fits T822, T834, T8034, T841, T874 with
M6130A
(48) Q674, WR1F46, and others
TG511D1004 Medium Universal Thermostat Guard with Beige painted
Dimensions, Approximate: 4 1/2 in. high x 2 15/16 in. wide x 1 1/2 in. steel cover, opaque ring base and wallplate Fits T822, T834, T8034,
deep (switches and wiring terminals protrude into outlet box 3/4 in.) T841, T874 with Q674, and others
(115 mm high x 75 mm wide x 39 mm deep (switches and wiring
terminals protrude into outlet box 19 mm))

Setting
Temperature Differential
Range Temperature Switch
Position
Product Number Application (F) (C) (F) (C) (System) Switching Action Description Includes
T451A3005 Heating 44 F to — 2F — — SPST- breaks on Thermostat, Medium Vertical scaleplate with
86 F temperature rise Duty Line Voltage, thermometer, range stops and
Application: heating, locking cover screws, wall plate,
Range: 44 F to 86 F high accuracy Dual Diaphragm
sensor.
T451B3004 Heating 50 F to — 2F — — SPST- breaks on Thermostat, Medium Vertical scaleplate with
86 F temperature rise; Duty Line Voltage, thermometer and high accuracy
with positive off Application: heating, dual diaphragm sensor
Range: 50 F to 86 F
• T651A3018 Heating and 44 F to — 2F — heating and SPDT - breaks Light Duty Line Vertical scaleplate with
cooling 86 F cooling heating and makes Voltage Thermostat. thermometer, horizontal
cooling on scaleplate with no thermometer,
temperature rise range stops and locking screws,
wall plate, and high accuracy
Dual Diaphragm sensor
T651A3026 Heating and — 7 C to — 1C heating and SPDT - breaks Light Duty Line Vertical scaleplate with
cooling 28 C cooling heating and makes Voltage Thermostat. thermometer, range stops and
Celsius cooling on locking screws, wall plate, high
temperature rise accuracy Dual Diaphragm
sensor.
* TRADELINE models • SUPER TRADELINE models

522 customer.honeywell.com 70-6910


Line Voltage Thermostats
T6051; T6052 Heavy Duty Line Voltage Thermostats

Controls
Home
Heavy Duty Line Voltage Thermostats used to control fan coils,
fans, motor starters, valves, contactors, and circulator motors in
heating and/or cooling systems.
• Provide good line voltage comfort control.
• Use with Q651A,B subbases for system and fan switching.
• Removable setpoint knob locks setpoint and prevents tampering.
• With locking cover.

Indoor Air Quality


Combustion Controls
Dimensions, Approximate: 5 in. high x 3 1/8 in. wide x 1 5/8 in. deep Approvals:

Residential
(127 mm high x 79 mm wide x 41 mm deep) Canadian Standards Association: CSA Certified: File no. LR1620
Electrical Ratings: Underwriters Laboratories, Inc. Listed: File No. E4436, Guide No.
120 Vac: 16 AFL, 96 ALR XAPX
240 Vac: 8 AFL, 48 ALR
Resistive 22A @ 120 Vac, 19 A @ 277 Vac
Accessories:
135531J Scaleplate, vertical, Celsius, 10 C to 25 C.
Pilot Duty 125 VA
23394B Locking guard for T42, T92, T451, T498, T651, T4051, T6051,
Electrical Connections: Screw terminals
T6052
Voltage: 120 Vac; 240 Vac
TG511A1000 Medium Universal Thermostat Guard with clear cover and

Hydronic Controls
Frequency: 50 Hz; 60 Hz
base, and opaque wallplate Fits T822, T834, T8034, T841, T874 with
Sensor Element: Vapor filled dual diaphragm
Q674, WR1F46, and others
Color: Plastic cover, tan
TG511D1004 Medium Universal Thermostat Guard with Beige painted
steel cover, opaque ring base and wallplate Fits T822, T834, T8034,
T841, T874 with Q674, and others

Setting
Temperature Switch
Range Differential Temperature Position
Switching Used
Product Number Application (F) (C) (F) (C) System Fan Action Description Includes With

Controls
Water
T6051A1016 Heating and 46 F to — 1F — — — SPDT Thermostat, Heavy Vertical Q651A, B
cooling 84 F Duty Line Voltage, mounting subbases
Application: Heating for system
and cooling, and fan
Use with: Q651A, B switching
subbases for system
and fan switching

Building Automation
* T6051A1057 Heating and — 8 C to — 0.6 C — — SPDT Thermostat, Heavy Vertical Q651A, B
cooling 29 C Duty Line Voltage, mounting subbases
Application: Heating for system
and cooling, Use and fan
with: Q651A, B switching
subbases for system
and fan switching
T6051B1006 Explosion- 46 F to — 1F — — — SPDT Heavy Duty Line Vertical —
proof, 84 F Voltage Thermostat mounting
Heating and
cooling

Components
Commercial
* T6052A1015 Two stage 46 F to — Stage 2 Heat, — 2-stage — 2 SPDT Heavy Duty Line Vertical or Q651A, B
heating or 84 F Stage 1 Cool: heating switches Voltage Thermostat horizontal subbases
two stage 3.2 F; Stage 1 or 2- mounting for system
cooling Heat, Stage 2 stage and fan
Cool: 2.5 F cooling switching
T6052A1023 Two stage — 8 C to — Stage 2 2-stage — 2 SPDT Heavy Duty Line Vertical or Q651C
heating or 29 C Heat, Stage heating switches Voltage Thermostat horizontal subbase
two stage 1 Cool: 1.8 or 2- mounting for system
Pneumatic Controls

cooling C; Stage 1 stage and fan


Heat, Stage cooling switching
2 Cool: 1.4 C
* T6052B1013 Heating and 46 F to — Stage 2 Cool: — 1-stage — 2 SPDT Heavy Duty Line Vertical or Q651A, B
cooling, auto 84 F 3.2 F; Stage 1 heating- switches Voltage Thermostat horizontal subbases
changeover Heat: 2.5 F cooling mounting for system
and fan
switching
* TRADELINE models • SUPER TRADELINE models
Industrial Combustion
Controls

70-6910 523
Line Voltage Thermostats
Dimensions in inches (millimeters)

ALLOW 1/2 IN. (12.7 MM)


CLEARANCE FOR
REMOVING KNOB
6-3/8 (162)
5-1/2 (140)
1-5/8 (41) 4-7/16 (113)
4-13/16 (122)

3-1/8 (79) PLUG

80 •
2-13/32
(61)
70 •
60 •
50 • 5-5/16
(135) 5-5/8
(143)

80 • 9/32 IN.
(7 MM) DIA.
2-13/32
70 • (2)
(61)
60 •
50 •

TAPPED FOR
3/4 IN. (17 MM)
CONDUIT (2)
M18852A
2-13/16 (71)

Line Volt Thermostat Replacement Parts and Accessories


Product Number Description Used With
135531J Scaleplate, vertical, Celsius, 10 C to 25 C. —
199923AA Plastic cover for T6051/T6052 with thermometer and setpoint scale. With ground strap. T6051/T6052
220124D Faceplate, horizontal, Celsius scale, for T651 models with thermometer. T651
272804A Range Stop and Locking Screws Assembly T410, T498, T4398

524 customer.honeywell.com 70-6910


Line Voltage Thermostats
Q651 Switching Subbase

Controls
Home
Provide manual system switching for T6051 and T6052
Thermostats.
• Provide positive OFF switching of the system.
• Mount vertically or horizontally on standard outlet box.
• Include pressure sensitive labels to identify switching positions.

Dimensions, Approximate: 5 13/16 in. high x 3 3/16 in. wide x 11/16

Indoor Air Quality


in. deep. (148 mm high x 81 mm wide x 18 mm deep)
Electrical Ratings:
16 A @ 120 Vac Full Load
8 A @ 240 Vac Full Load
96 A @ 120 Vac LR
48 A @ 240 Vac LR
Voltage: 120 or 240 Vac
Frequency: 60 Hz

Combustion Controls
Approvals:
Canadian Standards Association: Certified

Residential
Underwriters Laboratories, Inc. Listed: File No. E4436, Guide No.
XAPX
Accessories:
TG511A1000 Medium Universal Thermostat Guard with clear cover and
base, and opaque wallplate Fits T822, T834, T8034, T841, T874 with
Q674, WR1F46, and others
TG511D1004 Medium Universal Thermostat Guard with Beige painted

Hydronic Controls
steel cover, opaque ring base and wallplate Fits T822, T834, T8034,
T841, T874 with Q674, and others

Switch Position
Product Number Application System Fan Switching Action Includes Used With
Q651A1009 Subbase for See switch labels Provide positive OFF Switch labels: HEAT-OFF-COOL , HEAT- Thermostat: T6051A,
T6051A switching of the system OFF-FAN , AUTO-OFF-ON; Pressure Thermostat Guard:
sensitive labels to identify switching TG511 and TG512
positions

Controls
Water
Q651B1008 Subbase for See switch labels Provide positive OFF Switch labels: AUTO-OFF-FAN; Pressure Thermostat: T6051A,
T6051A switching of the system sensitive labels to identify switching Thermostat Guard:
positions TG511 and TG512

Building Automation
Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 525
Proportional Thermostats
T921 Proportional Thermostats
Proportional Thermostats provide low voltage, 3-wire control for
valve motors, damper motors, and balancing relays in heating or
cooling system applications.
• Bellows element adjusts potentiometer slider to regulate motor
operation.
• Removable setting knob prevents unauthorized tampering with
setpoint.

Dimensions, Approximate: 5 11/16 in. high x 3 3/8 in. wide x 2 1/4 in.
deep (144 mm high x 86 mm wide x 58 mm deep)
Mounting: Wall mount
Throttling Range: 2.5 F (1.4 C)

Setpoint Temperature Range


Product Number (F) (C) Output Signal Includes
T921A1183 — 13 C to 29 C 135 Ohm potentiometer Celsius model
* T921A1191 56 F to 84 F — 135 Ohm potentiometer Tradeline model which includes slotted sides and an add-on faceplate
to allow thermostat to be mounted horizontally.
T921G1005 56 F to 84 F — 135 Ohm potentiometer —
* TRADELINE models • SUPER TRADELINE models

Proportional Thermostat Parts and Accessories


Product Number Description Used With
100653A Potentiometer Assembly for use with T921 T921
124355/0047 Adjustment screw for TA42, T921, T473 —
130224 Knob - Adjusting —
4074BKB Envelope assembly for T921 —
50014156-002 Remote room sensor for the ZonePRO® ZonePRO
50014157-001 Duct temperature sensor for the ZonePRO® ZonePRO

526 customer.honeywell.com 70-6910


Proportional Thermostats
ZonePRO® Modulating/Floating Control Thermostats

Controls
Home
The ZonePRO® thermostats are for low-voltage pressure-
dependent variable air volume (VAV) applications. ZonePRO can
also be used for hydronic perimeter heating/cooling and bypass
box with or without reheat. The four models cover modulating
applications, floating applications and applications that require up
to two additional outputs for reheat.
• Provides modulating (2 to 10 Vdc analog) control (TB7980)

Indoor Air Quality


• Provides floating control (TB6980)
• Provides 2 additional outputs (TB6980B and TB7980B)
• Provides max. and min. setpoints for heating and cooling
• Provides a night setback (NSB) terminal for energy savings

Dimensions, Approximate: 2 5/8 in. wide X 4 9/16 in. high X 1 in. deep
(69 mm wide X 118 mm high X 27 mm deep)
Setpoint Temperature Range: 50F to 95F (10C to 35C)
Mounting: Wall mount

Combustion Controls
Power Supply: 24 Vac
Frequency: 60 Hz

Residential
Product Number Output Signal Output Signal Burden Additional Outputs Description
TB6980A1007 Floating 0.5A max @ 24Vac — Floating control
TB6980B1006 Floating 0.5A max @ 24Vac 1 Analog/TRIAC1 TRIAC Floating control with 2 additional outputs
TB7980A1006 0-10 Vdc or 2-10 Vdc 0-10V, 10k min — Modulating (0-10 Vdc) control

Hydronic Controls
TB7980B1005 0-10 Vdc or 2-10 Vdc 0.5A max @ 24Vac 1 Analog/TRIAC1 TRIAC Modulating (0-10 Vdc) control with 2 additional outputs
* TRADELINE models • SUPER TRADELINE models

ZonePRO® Modulating Thermostat Cross Reference


Product Number Replaces Compatible Valves Compatible Actuators Sensors and Accessories
TB6980A1007 T6984A1059 VC6930, VC6934, ML6984A1006, ML6420, R841 series of electromechanical relays,

Controls
VC6936, M6410, M6435 ML6161B2024, 50014157-001 air duct sensor,

Water
TB6980B1006 T6984D1046, T6984E1043 MN6105A1011 50014156-002 space sensor,
TB7980A1006 T7984A1057, T7984A1065 VC7930, VC7934, ML7984A4009, ML7420, ST6008A1003 and ST7009A1003 time clocks,
VC7936, M7410, M7435 ML7161A2008, 209651A wall plate,
TB7980B1005 T7984B1005, T7984C1053 MN7505A2001 D3 and D690 dampers

Building Automation
Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 527
Programmable Commercial Thermostats
Commercial Thermostat Cross Reference
User
Inter- Power
Model Schedule Options face Application Method Features and Functions

(Automatically Updates

Permanent Memory
Daylight Savings)

Dehumidification
Recovery Ramps

Communicating
Real Time Clock

Multiple Keypad
Lockout Levels
Conventional

Economizer
Modulating
Heat Pump
Temporary

Capability
Retention

LonWorks
Override
Program
Options

Fan Coil

Control
Holiday

Output
PTAC
Communicating T7350H1009 365- X X Soft 3 Heat/ 3 Heat/ No No No 24 Vac X X X X X 3 X
Day Keys 3 Cool or 370
2 Heat/ 2 Cool
4 Cool
T7350H1017 365- Yes X Soft 2 Heat/ N/A Two 4- No No 24 Vac X X X X X 3 X
Day Keys 1 Cool 20 mA
Modulating T7350M1008 365- Yes X Soft 1 Heat/2 N/A Two 4- No No 24 Vac X X X X X 3 X
Day Keys Cool or 20 mA
2 Heat/
1 Cool or
2 Cool/
1 Heat
Conventional/ T7350D1008 365- Yes X Soft 3 Heat/ 3 Heat/ No No No 24 Vac X X X X 3 X
Heat Pump and Day Keys 3 Cool or 2 Cool
T7351F2010 2 Heat/
4 Cool
T7350B1002 365- Yes X Soft 3 Heat/ 3 Heat/ No No No 24 Vac X X X X 3
Day Keys 2 Cool or 2 Cool
2 Heat/
3 Cool
T7350A1004 365- Yes X Soft 1 Heat/ 2 Heat/ No No No 24 Vac X X X X 3
Day Keys 2 Cool or 1 Cool
2 Heat/
1 Cool

Commercial TB8220U1003 7-Day Yes X Touch- 2 Heat/ 3 Heat/ No No No 24 Vac X X X X 4


VisionPRO® (Cumu screen 2 Cool 2 Cool or
8000 lative) Battery

Commercial TB7220U1012 7-Day Yes X Soft 2 Heat/ 3 Heat/ No No No 24 Vac X X X X 4


PRO® 7000 (Cumu Keys 2 Cool 2 Cool or
lative) Battery

MultiPRO™ TB7100A1000 7-Day Yes X Soft 1 Heat/ 2 Heat/ No 2 or 4 2 Heat/ 24 Vac Yes X X 5
7000 or non- (Cumu Keys 1Cool 1 Cool pipe 1 Cool or
pro- lative) Battery
gram-
mable

528 customer.honeywell.com 70-6910


Programmable Commercial Thermostats
Commercial Thermostat Cross Reference

Controls
Home
Model Features and Functions Display Information Replacements

White-Rodgers
Room and Set
Simultaneous
Backlighting

Backlighting

Temperature
Display Size

Robertshaw
On-Demand

Continuous

TCS Basys
(Viewable)

Display of

Honeywell

Invensys/
Sensing

Totaline
Remote

Carrier/

Indoor Air Quality


Communicating T7350H1009 Yes (Indoor, 4.2 sq. in. No Yes No All T7300's with No No No equivalent SZ1022,
Outdoor, Q7300H subbases equivalent equivalent offering SZ1024,
Discharge, offering offering SZ1031,
Humidity, SZ1033,
Occupancy) SZ1035,
SZ1009
T7350H1017 Yes (Indoor, 4.2 sq. in. No Yes No No previous No No No equivalent SZ1017a,
Outdoor, offering equivalent equivalent offering SZ1053

Combustion Controls
Discharge, offering offering
Humidity,

Residential
Occupancy)
Modulating T7350M1008 Yes (Indoor, 4.2 sq. in. No Yes No No previous No No No equivalent SZ1017a,
Outdoor, offering equivalent equivalent offering SZ1053
Discharge, offering offering
Humidity,
Occupancy)

Conventional/ T7350D1008 Yes (Indoor, 4.2 sq. in. No Yes No All T7300's with All White- All Invensys/ All Carrier/ SZ1022,

Hydronic Controls
Heat Pump and Outdoor, non Q7300H Rodgers Robertshaw Totaline SZ1024,
T7351F2010 Discharge, subbases Thermostats Thermostats Thermostats SZ1031,
Humidity, SZ1033,
Occupancy) SZ1035,
SZ1009
T7350B1002 Yes (Indoor, 4.2 sq. in. No Yes No All T7300's with All White- 9700i series, All Carrier/ SZ1022,
Outdoor, Q7300A and Rodgers 300 series Totaline SZ1024,
Discharge) Q7300C subbases Thermostats Thermostats SZ1031,
SZ1033,
SZ1009
T7350A1004 No 4.2 sq. in. No Yes No All T7300's with 1F90-371, 9700i, 9701i SZ1009
Q7300A2008 1F97-371,
subbase 1F96-344,

Controls
1F90-374,

Water
1F97-374
Commercial TB8220U1003 Yes (Indoor or 10 sq. in. Yes Yes Yes T7300 with 1F90 series, 9800 series, P374-2100,
VisionPRO® 8000 Outdoor) Q7300A2016, 1F80 series 9700i series, P374-2200,
Q7300A2008, 300 series P374-2300,
Q7300C2004 and 33CS250-01,
Q7300C2012 33CS220-01,
subbase 33CS071-01,
33CSSP2-WC,

Building Automation
33CSSN2-WC
CommercialPRO® TB7220U1012 Yes (Indoor or 4 sq. in. Yes Yes Yes T7300 with 1F90 series, 9800 series, P374-2100,
7000 Outdoor) Q7300A2016, 1F80 series 9700i series, P374-2200,
Q7300A2008, 300 series P374-2300,
Q7300C2004 and 33CS250-01,
Q7300C2012 33CS220-01,
subbase 33CS071-01,
33CSSP2-WC,
33CSSN2-WC
MultiPRO™ 7000* TB7100A1000 Yes (Indoor or 4 sq. in. Yes Yes Yes T8574B2016, IF90-371, 97012, 9610, P274-0100, SZ1-61,
Occupancy) T8575B2007, IF96-344, 9700i, P274-1100, SZ1062

Components
T8575C2005, IF97-371, 300-224, P374-0200,

Commercial
T8575D2003 IF80-224, 300-225, P374-0300
IF80-241, 300-226,
IF80-261,
IF86-244,
IF87-251,
IF82-261,
IF89-211
* The MultiPRO™ 7000 also replaces the following models for PSG Controls: DFC-20YU6585F,
DPFC-024U2F,
Pneumatic Controls

DPFC-024K2F,
TDMS24-AH22CB
Industrial Combustion
Controls

70-6910 529
Programmable Commercial Thermostats
Honeywell Thermostat Sensors Cross Reference
Model Number Sensor Type Selectable Setpoint
Adjustment
55° to 85°F Override
Honeywell Wall Replaces Sensor 13° to 30°C Button Fan
Module Model Honeywell Model Element Type Temperature Humidity Relative (- to +) with LED LON Jack Switching
TR21 T7770A1006 3
20K ohms non-
linear

TR21-A T7770A3002 3
10K ohms non-
linear for
averaging only

TR21-H N/A 3 3 3
TR21-J T7770A2004 3 3
TR22 T7770B1004 3 3 3
T7770B1020
T7770B1046

TR23 T7770C1002 3 3 3 3
T7770C1028
T7770C1044
20K ohms non-
linear
TR23-H N/A 3 3 3 3 3
TR23-N* T7770C1051 3 3 3 3
TR24 T7770D1000 3 3 3
TR22-F5 N/A 3 3 3 5 position

TR23-F3 T7770E1023 3 3 3 3 3 position

TR23-F5 T7770F1005 3 3 3 3 5 position

* No Honeywell Logo

530 customer.honeywell.com 70-6910


Programmable Commercial Thermostats
Commercial VisionPRO® 8000

Controls
Home
The TB8220 Commercial VisionPRO 8000 Touchscreen
Programmable Thermostat is an effortless, seven day
programmable thermostat that provides universal system
compatibility, precise comfort control and is easy to program. The
TB8220 provides temperature control for gas, oil, electric and heat
pumps for up to 2 heat, 2 cool systems.
• Large, clear display with backlight shows the current and set

Indoor Air Quality


temperature and time even in the dark.
• Menu-driven programming make setup effortless.
• Beautiful ergonomic design is smart and sophisticated to match your
customers' lifestyle.
• Touchscreen interaction Real-time clock keeps time during power
failures and automatically updates to daylight savings.
• Saving Changes notification lets you know when the schedule
changes have been saved.
• Change reminders let you know when to replace the batteries.

Combustion Controls
• Holiday Override options allow you to override the program
schedule, as desired.

Residential
• Speedy same--schedule programming--no need to copy multiple
days.
• Armchair programming allows you to remove the thermostat from the
wall for programming.
Dimensions in inches (millimeters)
WALLPLATE Color: Premier White®
3-3/8 (86) Electrical Connections: 24 VAC or Battery

Hydronic Controls
Network Communications: None
Dimensions, Approximate: 6 in. wide x 4 9/16 in. high x 1 3/8 in. deep
(152 mm wide x 116 mm high x 35 mm deep)
Accessories:
32003796-001 Premier White® cover plate 7 7/8 in. (200 mm) x 5 1/2 in.
(140 mm)
3-3/8 (86)
TR21 20 K ohm NTC non-linear Temperature Wall Module
TR21-A 10 K ohm NTC non-linear Temperature Wall Module (for
averaging only)
C7189U1005 Remote Indoor Sensor
C7770A1006 6 in. Duct Probe for Return Air 20 K ohm NTC non-linear

Controls
Water
Temperature Sensor
THERMOSTAT C7772A1004 20 K ohm NTC non-linear Wall Flush Mount Temperature
THERMOSTAT
AND WALLPLATE Sensor without logo
1-3/8 (35) C7772A1012 20 K ohm NTC non-linear Wall Flush Mount Temperature
6 (152)
Sensor with Honeywell logo
C7041B2005 20K ohm NTC Temperature Sensor with 6 in. insertion
C7041B2013 20K ohm NTC Temperature Sensor with 12 in. insertion

Building Automation
C7041C2003 20K ohm NTC Temperature Sensor with 18 in. insertion
C7041P2004 20K ohm NTC Stainless Steel Button Sensor, 11/16 in.
dia.
C7089U1006 Remote Outdoor Sensor
4-9/16
(116)
W7212A1009 Series 72 Economizer Logic Module with Demand
Control Ventilation

Components
Commercial
M22421

Setting Temperature
Switch Position Range
Terminal
Product Number Application System Fan Designations Stages (F) (C) Comments
TB8220U1003 24 Vac heating and HEAT- AUTO- R, Rc, W (O/B), Up to 2 Heat/ Heat: 40 F Heat: 4.5 C The L-terminal is an input
Pneumatic Controls

cooling systems; OFF- ON W2 (W1), Y, Y2, 2 Cool to 90 F; to 32 C; only;


Heat Pump Systems; COOL- L, A, G, C, S1, S2 Conventional; Cool: 50 F Cool: 10 C Selectable programmable
Conventional AUTO- Up to 3 Heat/ to 99 F to 37 C or non-programmable;
systems; Packaged EM.HEAT 2 Cool Heat Pump Includes A terminal to
RTU enable an economizer or
control a lighting panel
when used as a time of day
relay
Industrial Combustion
Controls

70-6910 531
Programmable Commercial Thermostats
CommercialPRO® 7000
The COMMERCIALPRO® 7000 Programmable Thermostat is an
effortless, seven-day programmable thermostat that provides
universal system compatibility, precise comfort control and is
easy-to-program.
The TB7220 provides temperature control for gas, oil, electric and
heat pumps for up to 2 heat, 2 cool systems.
• Large, clear display with backlight shows the current and set
temperature and time--even in the dark.
• Menu-driven programming make setup effortless.
• Beautiful ergonomic design is smart and sophisticated to match your
customers’ lifestyle.
• Real-time clock keeps time during power failures and automatically
updates to daylight savings.
• Saving Changes notification lets you know when the schedule
changes have been saved.
• Change reminders let you know when to replace the batteries.
• Holiday Override options allow you to override the program
schedule, as desired.
• Speedy same--schedule programming--no need to copy multiple
days.
• Armchair programming allows you to remove the thermostat from the
wall for programming.

Dimensions in inches (millimeters)


Color: Premier White®
Electrical Connections: 24 VAC or Battery
Network Communications: None
Dimensions, Approximate: 6 in. wide x 3 3/4 in. high x 1 3/8 in. deep
(152 mm wide x 96 mm high x 35 mm deep)
Accessories:
50002883-001 FocusPRO 5000/6000 and PRO 3000/4000 Cover Plate
Assembly
TR21 20 K ohm NTC non-linear Temperature Wall Module
TR21-A 10 K ohm NTC non-linear Temperature Wall Module (for
THERMOSTAT
AND WALLPLATE
averaging only)
C7189U1005 Remote Indoor Sensor
6 (152)
1-3/8 C7770A1006 6 in. Duct Probe for Return Air 20 K ohm NTC non-linear
(35) Temperature Sensor
C7772A1004 20 K ohm NTC non-linear Wall Flush Mount Temperature
Sensor without logo
C7772A1012 20 K ohm NTC non-linear Wall Flush Mount Temperature
Sensor with Honeywell logo
C7041B2005 20K ohm NTC Temperature Sensor with 6 in. insertion
3-3/4
(95)
C7041B2013 20K ohm NTC Temperature Sensor with 12 in. insertion
C7041C2003 20K ohm NTC Temperature Sensor with 18 in. insertion
C7041P2004 20K ohm NTC Stainless Steel Button Sensor, 11/16 in.
dia.
C7089U1006 Remote Outdoor Sensor
W7212A1009 Series 72 Economizer Logic Module with Demand
Control Ventilation
M13668

Setting Temperature
Switch Position Range
Terminal
Product Number Application System Fan Designations Stages (F) (C) Comments
TB7220U1012 24 Vac heating and HEAT- AUTO- R, Rc, W (O/ Up to 2 Heat/ Heat: 40 F Heat: 4.5 C Selectable programmable or non-
cooling systems; OFF- ON B), W2 (W1), 2 Cool to 90 F; to 32 C; programmable;
Heat Pump Systems; COOL- Y, Y2, A, G, C, Conventional; Cool: 50 F Cool: 10 C Includes A terminal to enable an
Conventional AUTO- S1, S2 Up to 3 Heat/ to 99 F to 37 C economizer or control a lighting
systems; Packaged EM.HEAT 2 Cool Heat panel when used as a time of day
RTU Pump relay

532 customer.honeywell.com 70-6910


Programmable Commercial Thermostats
MultiPRO™ 7000

Controls
Home
• Large, clear display with backlight shows the current and set
temperature and time--even in the dark.
• Menu-driven programming make setup effortless.
• Beautiful ergonomic design is smart and sophisticated to match your
customers’ lifestyle.
• Real-time clock keeps time during power failures and automatically
updates to daylight savings.

Indoor Air Quality


• Saving Changes notification lets you know when the schedule
changes have been saved.
• Change reminders let you know when to replace the batteries.
• Holiday Override options allow you to override the program
schedule, as desired.
• Speedy same--schedule programming--no need to copy multiple
days.
• Armchair programming allows you to remove the thermostat from the
wall for programming.

Combustion Controls
The MultiPRO™ Multispeed and Multipurpose Thermostat is an
• Programmable or non-programmable modes.
effortless, seven-day programmable or non-programmable
• Remote setback input for occupancy sensors or timeclocks.

Residential
thermostat that provides universal system compatibility, precise
• VersaSpeed™ fan ramping algorithm and fan reset algorithm (fan
comfort and is easy to program.
coil and PTAC applications).
The MultiPRO provides temperature control for gas, oil, electric, • Up to 3 fan speeds for fan coil and 2 fan speeds for PTAC
heat pumps, PTACs, and fan-coil equipment for the following types applications.
of applications: 1H/1C conventional; Up to 2H/1C heat pump; 4 • Remote Indoor air sensing option (20K ohm or 10K ohm)
pipe fan coil (3 fan speeds); 2 pipe fan coil (3 fan speeds); 2 pipe
fan coil w/Auxiliary Heat (3 fan speeds); PTAC (Hi, Lo fan speeds).

Hydronic Controls
Color: Premier White® C7770A1006 6 in. Duct Probe for Return Air 20 K ohm NTC non-linear
Electrical Connections: 24 VAC or Battery Temperature Sensor
Network Communications: None C7772A1004 20 K ohm NTC non-linear Wall Flush Mount Temperature
Sensor without logo
Accessories: C7772A1012 20 K ohm NTC non-linear Wall Flush Mount Temperature
50002883-001 FocusPRO 5000/6000 and PRO 3000/4000 Cover Plate Sensor with Honeywell logo
Assembly C7041B2005 20K ohm NTC Temperature Sensor with 6 in. insertion
TR21 20 K ohm NTC non-linear Temperature Wall Module C7041B2013 20K ohm NTC Temperature Sensor with 12 in. insertion
TR21-A 10 K ohm NTC non-linear Temperature Wall Module (for C7041C2003 20K ohm NTC Temperature Sensor with 18 in. insertion
averaging only) C7041P2004 20K ohm NTC Stainless Steel Button Sensor, 11/16 in.
C7189U1005 Remote Indoor Sensor dia.

Controls
WSK-24 Wireless Occupancy Solution

Water
Setting Temperature
Switch Position Range
Terminal
Product Number Application System Fan Designations Stages (F) (C) Comments
TB7100A1000 Conventional, HEAT- AUTO-ON; R, Rc, W1, O/B, 1 Heat/ 1Cool Heat: 40 F Heat: 4.5 C Includes 3 speed fan

Building Automation
Heat Pump, OFF- Fan Coil: HI- Y, G, G2, G3, C, Conventional; to 90 F; to 32 C; control and configurable
Fan Coil, and COOL- MED-LO-AUTO; S1, S2 Up to 2 Heat/ Cool: 50 F Cool: 10 C sensor input for indoor
PTAC Systems AUTO- PTAC: HI-LO- 1 Cool Heat Pump; to 99 F to 37 C temperature, occupancy
EM.HEAT AUTO 2 or 4 pipe Fan sensor, or changeover;
Coil; Selectable
Up to 2 Heat/ 1 programmable or non-
Cool PTAC programmable

Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 533
Programmable Commercial Thermostats
T7350 Programmable Commercial Thermostats
• 365-day programming.
• Two Occupied and two Not Occupied periods per day.
• Thermostat Interface Module (TIM) connections to thermostat from
PDA for advanced configuration, programming, keypad lockout, etc.
• Individual heat and cool setpoints available for Occupied and Not
Occupied periods.
• P+I+D control minimizes temperature fluctuations.
• Recovery ramping control automatically optimizes equipment start
times based on building load.
• Universal Versaguard™ Thermostat guards available.
• Convenient overrides allow temporary setpoint changes.
• Keypad multi-level lockout available with all models.
• Remote sensor capability - EXCEPT T7350A model - for
temperature (including outdoor air and discharge air) and humidity
sensors.
• Auxiliary contact interfaces with a Honeywell Economizer System
(for total rooftop control integration) or as a dehumidification output.
T7350 Thermostats control 24 Vac commercial single-zone
multistage conventional, heat pump and modulating HVAC
equipment.

Dimensions in inches (millimeters) Accessories:


C7041B2005 20K ohm NTC Temperature Sensor with 6 in. insertion
2-3/16 (56) C7041B2013 20K ohm NTC Temperature Sensor with 12 in. insertion
6-3/4 (171)
1-9/16 C7041R2000 20K ohm NTC 12 ft Flexible Copper Averaging
(40)
Temperature Sensor
C7089A1002 Remote Outdoor Sensor
H7625A1008 Humidity Transmitter, 2% RH accuracy, wall mount, with
optional 20K ohm temp output
H7625B1006 Humidity Transmitter, 2% RH accuracy, duct mount, with
4-1/2 optional 20K ohm temp output
(114) H7635A1006 Humidity Transmitter, 3% RH accuracy, wall mount, with
optional 20K ohm temp output
H7635B1004 Humidity Transmitter, 3% RH accuracy, duct mount, with
optional 20K ohm temp output
H7655A1001 Humidity Transmitter, 5% RH accuracy, wall mount,
without temp output
H7655B1009 Humidity Transmitter, 5% RH accuracy, duct mount, with
SUBBASE
optional 20K ohm temp output
T7771A1005 20 K ohm NTC non-linear Temperature Wall Module
2-1/32 TR21 20 K ohm NTC non-linear Temperature Wall Module
(52) TR21-A 10 K ohm NTC non-linear Temperature Wall Module (for
4-1/16 averaging only)
(104) TR22 20 K ohm NTC non-linear Temperature Wall Module with Setpoint
adjustment
2-1/32
TR23 20 K ohm NTC non-linear Temperature Wall Module with Override
(52) and Setpoint adjustment
TR23-H 20 K ohm NTC non-linear Temperature Wall Module with
Humidity
1-5/8 2-3/8 (60) 1-5/8 TR24 20 K ohm NTC non-linear Temperature Wall Module with Override
(42) 3-1/4 (83) (42) TR21-H 20 K ohm NTC non-linear Temperature Wall Module with
6-9/16 (166) M22432 Humidity
W7212A1009 Series 72 Economizer Logic Module with Demand
Color: Trident White Control Ventilation
Electrical Connections: 24 Vac, 50/60 Hz; 20 to 30 Vac, 50/60 Hz. WSK-24 Wireless Occupancy Solution
Network Communications: None

Switch Position
Product Number Application System Fan Stages Comments
T7350A1004 Conventional and Heat HEAT-OFF-COOL- AUTO-ON 1 Heat/1 Cool —
Pump systems AUTO-EM.HEAT
T7350B1002 Conventional and Heat HEAT-OFF-COOL- AUTO-ON 2 Heat/2 Cool Remote Temp, Outdoor, Discharge Air
Pump systems AUTO-EM.HEAT
T7350D1008 Conventional and Heat HEAT-OFF-COOL- AUTO-ON 3 Heat/3 Cool Remote Temp, Outdoor, Discharge Air,
Pump systems AUTO-EM.HEAT Humidity, Occupancy
T7350M1008 Modulating Systems HEAT-OFF-COOL- AUTO-ON 2 Mod (4-20mA)/ 2 Relay Remote Temp, Outdoor, Discharge Air,
AUTO-EM.HEAT Humidity, Occupancy

534 customer.honeywell.com 70-6910


Programmable Commercial Thermostats
T7351F Programmable Commercial Thermostats

Controls
Home
• Typically used in buildings (including: restaurants, shopping malls,
office buildings and banks) under 55,000 square feet.
• For single zone rooftop units, split systems, heat pumps or hot/
chilled water systems.
• 365-day programming.
• Two Occupied and two Not Occupied periods per day.
• Individual heat and cool setpoints available for Occupied and Not

Indoor Air Quality


Occupied periods.
• P+I+D control minimizes temperature fluctuations.
• Recovery ramp control automatically optimizes equipment start
times based on building load.
• Convenient overrides allow temporary setpoint changes.
• Keypad multi-level lockout available with all models.
• Remote sensor capability for temperature (including outdoor air and
discharge air) and humidity sensors.
• Auxiliary subbase contact typically interface with a Honeywell

Combustion Controls
Economizer System (for total rooftop control integration) or act as
The T7351 Commercial Programmable Thermostat controls 24 Vac dehumidification output.

Residential
commercial single zone heating, ventilating and air conditioning • Universal Versaguard Thermostat guards available.
(HVAC) equipment. The T7351 consists of a thermostat and
subbase. The thermostat includes the keypad and display for 365-
day programming. The subbase includes equipment control
connections. The subbase mounts on the wall and the thermostat
mounts to the subbase.

Dimensions in inches (millimeters) Accessories:

Hydronic Controls
C7041B2005 20K ohm NTC Temperature Sensor with 6 in. insertion
2-3/16 (56) C7041B2013 20K ohm NTC Temperature Sensor with 12 in. insertion
6-3/4 (171)
1-9/16 C7041R2000 20K ohm NTC 12 ft Flexible Copper Averaging
(40)
Temperature Sensor
C7089A1002 Remote Outdoor Sensor
H7625A1008 Humidity Transmitter, 2% RH accuracy, wall mount, with
optional 20K ohm temp output
H7625B1006 Humidity Transmitter, 2% RH accuracy, duct mount, with
4-1/2 optional 20K ohm temp output
(114) H7635A1006 Humidity Transmitter, 3% RH accuracy, wall mount, with
optional 20K ohm temp output

Controls
Water
H7635B1004 Humidity Transmitter, 3% RH accuracy, duct mount, with
optional 20K ohm temp output
H7655A1001 Humidity Transmitter, 5% RH accuracy, wall mount,
without temp output
H7655B1009 Humidity Transmitter, 5% RH accuracy, duct mount, with
SUBBASE
optional 20K ohm temp output
T7771A1005 20 K ohm NTC non-linear Temperature Wall Module

Building Automation
2-1/32 TR21 20 K ohm NTC non-linear Temperature Wall Module
(52) TR21-A 10 K ohm NTC non-linear Temperature Wall Module (for
4-1/16 averaging only)
(104) TR21-H 20 K ohm NTC non-linear Temperature Wall Module with
Humidity
2-1/32
TR22 20 K ohm NTC non-linear Temperature Wall Module with Setpoint
(52) adjustment
TR23 20 K ohm NTC non-linear Temperature Wall Module with Override
and Setpoint adjustment
1-5/8 2-3/8 (60) 1-5/8 TR23-H 20 K ohm NTC non-linear Temperature Wall Module with

Components
Commercial
(42) 3-1/4 (83) (42) Humidity
6-9/16 (166) M22432 TR24 20 K ohm NTC non-linear Temperature Wall Module with Override
WSK-24 Wireless Occupancy Solution
Color: Trident White W7212A1009 Series 72 Economizer Logic Module with Demand
Electrical Connections: 24 Vac, 50/60 Hz; 20 to 30 Vac, 50/60 Hz. Control Ventilation
Network Communications: None

Switch Position
Pneumatic Controls

Product Number Application System Fan Stages Comments


T7351F2010 Conventional and Heat HEAT-OFF-COOL-AUTO- AUTO-ON 3 Heat/3 Cool Remote Temp, Outdoor, Discharge Air,
Pump systems EM.HEAT Humidity, Occupancy
Industrial Combustion
Controls

70-6910 535
Programmable Commercial Thermostats
Commercial Thermostat Accessories
Product Number Description Used With
209651A Wallplate T7350
50014064-001 Infra Red Thermostat Interface Module (IR-TIM), allows PDA to be connected T7350
to the T7350

536 customer.honeywell.com 70-6910


InfraRed Thermostat Interface (IR-TIM)
InfraRed Thermostat Interface Module (IR-TIM) - 50014064-001

Controls
Home
T7350 Handheld and Smartphone Compatibility List
Below is a complete list of all the tested and compatible handhelds and
smartphones for programming the T7350 thermostats. These handhelds
have been tested using the IR-TIM (Product number 50014064-001).

Indoor Air Quality


Handheld or InfraRed
smartphone Thermostat
Brand Model OS Interface Module
Palm i705 4.x X
Palm m105 3.5 X
Palm Vx 3.5 X
Palm m125 4.5 X

Combustion Controls
Palm Zire71 5.2.1 X
HandEra TRGpro 3.5x X

Residential
Palm Tungsten T 5.0 X
Palm m125 4.x X
Palm Tungsten™ C 5.2.1 X
Palm Tungsten T2 5.2.1 X
Palm Tungsten T3 5.2.1 X
This InfraRed Thermostat Interface Module (IR-TIM) allows a PDA

Hydronic Controls
to be connected wirelessly to the T7350 Thermostat. Palm Zire 31™ 5.2.8 X
Palm Zire 21 5.2.1 X
Palm Zire 71 5.2.8 X
Palm Treo™ 650 5.4 X
Palm E2 5.4 X
Palm TX 5.4 X
Palm LifeDrive 5.4 X
Sony PEG-TJ27 5.2.1 X

Controls
Water
Treo 650 5.4 X
Treo 680 5.4.9 X
Treo 700p 5.4.9 X
Treo 755p 5.4.9 X

Non-Compatible T7350 Handhelds and Smartphones

Building Automation
The following models are not compatible with the T7350:
— Zire 22
— Treo 750
— Treo 700wx
— Treo 700w
— All handhelds and smartphones with Windows Mobile (5.0) oper-
ating system

Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 537
Communicating Thermostats
T7350 Communicating Programmable Commercial Thermostats
• 365-day programming.
• Two Occupied and two Not Occupied periods per day.
• Thermostat Interface Module (TIM) connections to thermostat from
PDA for advanced configuration, programming, keypad lockout, etc.
• Individual heat and cool setpoints available for Occupied and Not
Occupied periods.
• P+I+D control minimizes temperature fluctuations.
• Recovery ramping control automatically optimizes equipment start
times based on building load.
• Universal Versaguard™ Thermostat guards available.
• Convenient overrides allow temporary setpoint changes.
• Keypad multi-level lockout available with all models.
• Remote sensor capability for temperature (including outdoor air and
discharge air) and humidity sensors.
• Auxiliary contact interfaces with a Honeywell Economizer System
(for total rooftop control integration) or as a dehumidification output
LONWORKS® network communication.
T7350H Communicating Thermostats control 24 Vac commercial
single-zone multistage conventional, heat pump and modulating
HVAC equipment. Additionally, the T7350H allows remote access
and the sharing of clock, schedule, setpoints, bypass and other
system parameters with other devices in a LONWORKS® network.
Color: Trident White H7655B1009 Humidity Transmitter, 5% RH accuracy, duct mount, with
Network Communications: LonWorks Bus and PDA Serial Port optional 20K ohm temp output
T7771A1005 20 K ohm NTC non-linear Temperature Wall Module
Accessories: TR21 20 K ohm NTC non-linear Temperature Wall Module
C7041B2005 20K ohm NTC Temperature Sensor with 6 in. insertion TR21-A 10 K ohm NTC non-linear Temperature Wall Module (for
C7041R2000 20K ohm NTC 12 ft Flexible Copper Averaging averaging only)
Temperature Sensor TR21-H 20 K ohm NTC non-linear Temperature Wall Module with
H7625A1008 Humidity Transmitter, 2% RH accuracy, wall mount, with Humidity
optional 20K ohm temp output TR22 20 K ohm NTC non-linear Temperature Wall Module with Setpoint
H7625B1006 Humidity Transmitter, 2% RH accuracy, duct mount, with adjustment
optional 20K ohm temp output TR23 20 K ohm NTC non-linear Temperature Wall Module with Override
H7635A1006 Humidity Transmitter, 3% RH accuracy, wall mount, with and Setpoint adjustment
optional 20K ohm temp output TR23-H 20 K ohm NTC non-linear Temperature Wall Module with
H7635B1004 Humidity Transmitter, 3% RH accuracy, duct mount, with Humidity
optional 20K ohm temp output TR24 20 K ohm NTC non-linear Temperature Wall Module with Override
H7635C1002 Humidity Transmitter, 3% RH accuracy, outdoor mount, W7212A1009 Series 72 Economizer Logic Module with Demand
with optional 20K ohm temp output Control Ventilation
H7655A1001 Humidity Transmitter, 5% RH accuracy, wall mount, WSK-24 Wireless Occupancy Solution
without temp output

Switch Position
Product Number Application System Fan Stages Comments Includes
T7350H1009 Conventional and Heat HEAT-OFF-COOL- AUTO-ON 3 Heat/3 Cool Remote Temp, Outdoor, Discharge Air, —
Pump systems AUTO-EM.HEAT Humidity
T7350H1017 Modulating Systems HEAT-OFF-COOL- AUTO-ON 2 Mod (4-20mA)/ Remote Temp, Outdoor, Discharge Air, —
AUTO-EM.HEAT 2 Relay Humidity and Occupancy
Y7355H1009 Conventional and Heat HEAT-OFF-COOL- AUTO-ON 3 Heat/3 Cool Remote Temp, Outdoor, Discharge Air, T7350H1009,
Pump systems AUTO-EM.HEAT Humidity, Occupancy C7041B2005,
T7771A1005

538 customer.honeywell.com 70-6910


WebStat Controller
WebStat® Controller

Controls
Home
WebStat allows you to step up from standalone thermostat control
to the automated T7350 communicating thermostat platform
without incurring any excessive direct digital control (DDC) cost or
complexity. Automation features include web control, alarming,
trending, scheduling, network accessibility, and floor plans.
Operational savings are enabled by remote monitoring, alarming,
floor plan visuals and thermostat assignment privileges for

Indoor Air Quality


tenants, facility managers and contractors. WebStat keeps control
simple by allowing Internet accessibility and flexibility for
assigning user privileges.
• Remote Monitoring
• Remote Programming
• Up to 20 T7350H Thermostats
• Plug-and-Play Setup
• Universal Programming, Commissioning and Graphics Tool
• Alarm Email Notification

Combustion Controls
• Trending
• Thermostat Self-Discovery

Residential
• Wiring Diagram Generation Tool
Dimensions, Approximate: 6 3/8 in. wide x 4 7/64 in. high x 2.5 in. Approvals:
deep (16.2 cm wide x 10.5 cm high x 6.4 cm deep) Canadian Standards Association: CSA C22.2 No. 205-M1983 Signal
Application Size: Up to 20 T7350H Thermostats with free software Equipment
upgrade CE: Approved
Operating Temperature Range: 32 F to 122 F (0 C to 50 C) Federal Communications Commission: FCC part 15 Class A
Operating Humidity Range (% RH): 5 to 95% RH, non-condensing Underwriters Laboratories, Inc. UL 916, C-UL listed

Hydronic Controls
Shipping Temperature Range: 32 F to 140 F (0 C to 60 C)

Network Commissioning
Product Number Application Communications Software Compatible with Includes Used With
W7350A1000 Controller LonWorks WebStat T7350H Communicating Lon Card and LonWorks bus
Thermostats Power Supply

Controls
Water
Building Automation
Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 539
Commercial Thermostat Resources
Honeywell Building Controls’ Web Sites/Electronic Resources
Main Customer Web Site/Product and that section’s listing on the right side of the screen. All modules
feature an interactive quiz to help you review the material. After
Technical Literature 4.
you finish this quiz, the training is complete.
Trainings Include:
customer.honeywell.com a. Building Automation (LCBS) Products
i. WebStat Programming and Configuration –
Course #63-9625
New Products – Buildings’ Product Showcase ii. WebStat Installation and Networking – Course #63-9626
Contains trainings, marketing materials, and literature on new thermo- b. Building Controls Products
stat products. i. Commercial Thermostats – Course #63-9605
customer.honeywell.com/buildings ii. T7351 Basic Training – Course #63-9600
iii. T7351 Advanced Training – Course #63-9601 (Must
Buildings Forum take Basic Training first)
iv. Commercial VisionPRO 8000 Basic Training – Course
buildingsforum.honeywell.com #63-9602
v. CommercialPRO 7000 Basic Training – Course
Honeywell Promotional Materials #63-9603
vi. ZonePRO Basic Training – Course #63-9604
honeywell.promocollection.com vii. MultiPRO Basic Training – Course #67-7200
viii. SuitePRO Basic Training – Course #67-7201
Literature Ordering Site
literature.honeywell.com Product Resources
These sites contain information on Buildings’ Products, and include
Applications and Downloads access to Product Features, Marketing Materials, and Training Presen-
tations.
Contains valuable Commercial Thermostat tools, including the Energy
Estimating Tool and Commercial Thermostat Code Compliance Tool –
ComCheck 3.3.1. Also contains T7350 Stat downloads, including Palm WebStat® Controller
Software, PC Emulator, and Configuration Code Spreadsheet.
http://customer.honeywell.com/webstat
http://customer.honeywell.com/Business/Cultures/
en-US/Products/Applications+and+Downloads/
T7351 Thermostat
http://customer.honeywell.com/t7351
WebStat® Demo Site
www.webstathoney
ZonePRO® Modulating Thermostat
well.com
http://customer.honeywell.com/zonepro
User ID: honeywell
Password: honeywell
CommercialPRO® 7000
Rapid Zone® Website http://customer.honeywell.com/cpro
customer.honeywell.com/rapidzone
Commercial VisionPRO® 8000
eLearning Training Modules http://customer.honeywell.com/cvp
http://customer.honeywell.com/learning
SuitePRO™ Digital Fan Coil Thermostat
Training presentations are available 24/7 at this site, so you can access
the trainings whenever is best for you. http://customer.honeywell.com/suitepro
1. Go to the website above and log in to your customer.honey-
well.com account. If you need a login, just register and you’ll MultiPRO™ 7000
have access within about 24 hours. http://customer.honeywell.com/multipro
2. Click on where it says “Please click here to browse our
eLearning Modules.” This will open up a new window with the
eLearning Training Modules.
3. From this spot you can click on the product that you want and the Commercial Thermostat Literature – Useful literature
module will launch from your screen with visuals accompanied by
an informational audio presentation. The section listings on the
on Commercial Thermostats
right will help you track your progress and know the approximate — 63-9610 – Commercial Thermostats Application and Cross
time remaining in each section as well as for the complete mod- Reference Guide
ule. If you nee to pause it, just click the pause button at the bot- — 63-9620 - Commercial Thermostats Application and Cross
tom of the screen. If you wish to repeat a section simply click on Reference Guide (General Wholesaler Version)
— 95C-10897 – T6570, T8570 Digital Fan Coil Stat Product Data
Sheet
— 63-2658 WebStat User Guide

540 customer.honeywell.com 70-6910


Timers
ST6008 Energy Management Timers

Controls
Home
• Battery backup (quartz drive).
• Screw wiring terminals.
• Three-way override.
• Captive trippers.

Dimensions, Approximate: 4 1/4 in. high x 2 15/16 in. wide x 2 1/4 in.
deep (108 mm high x 75 mm wide x 57 mm deep)

Indoor Air Quality


Electrical Connections (in.): Screw terminals
Mounting: Surface or on DIN rail
Voltage: 120 Vac
Frequency: 60 Hz
Ambient Temperature Range: -40 F to +180 F (-40 C to +82 C)
Operating Humidity Range (% RH): 0 to 95% RH
Approvals:
Canadian Standards Association: Certified: File No. LR52379

Combustion Controls
Underwriters Laboratories, Inc. Listed File: E83486
Provide 24-hour or 7-day time-based switching.

Residential
• Universal application with 24-hour or 7-day programming.

Product Number Clock Type Minimum Timing Switching Switch Ratings


ST6008A1006 24-hours synchronous 15 min 1 SPDT 1350 W tungsten21 A resistive @ 250 V
ST6008B1005 7-day synchronous 2 hrs 1 SPDT 22 A resistive @ 250 V1350 W tungsten
ST6008C1004 7-day quartz (7 day battery reserve) 2 hrs 1 SPDT 23 A resistive @ 250 V1350 W tungsten

Hydronic Controls
Controls
Water
Building Automation
Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 541
Pressure-regulated Control Valves
NPT Dynamic Pressure-regulated Control Valves
balance the system for proper flow, and allow chillers to be
operated at design temperature differential for maximum efficiency
at every load condition. When used in a system with variable
speed pump drives, 3-way valves and coil bypass lines are not
required. In new construction, VRN2 valves perform better than
reverse return piping designs without the extra materials these
systems need.
Systems that utilize the capabilities of properly installed and
monitored pressure-independent control valves may qualify for
LEED points. Pressure-independent control requires less flow,
enabling use of smaller piping, pumps, and chillers.
• Sizes from 1/2 to 3 in. with internal (female) NPT connections.
• Controls hot or chilled water with up to 50% glycol.
• Regulated flow rates available from 1 to 95 gpm.
• Differential pressure regulator for constant pressure drop across
valve seat.
The VRN2 two-way dynamic pressure-regulating control ball • Positive pressure, rolling diaphragm regulator design for long service
valves maintain constant flow of hot or chilled water in closed loop life for flow control accuracy of ±5% over specified control range.
heating, ventilating, and air conditioning (HVAC) systems • Equal percentage flow characteristic using patented flow control ball
regardless of head pressure fluctuations above the minimum insert.
specified pressure drop. These valve assemblies can be used with • Multiple regulated flow rates available per valve size.
Honeywell non-spring return or spring return direct coupled • Patented ball seals require low operating torque.
actuators (DCA) with minimum torque of 35 lb-in (4 Nm) on valve • Nickel-chrome plated brass or stainless steel trim.
sizes up to 3 inches (DN80). • Choice of factory-installed actuation using Honeywell N05/S05-
series direct-coupled actuators: Floating, Modulating (2-10 V),
The built-in differential pressure regulator makes fluid flow
Spring Return Modulating/Floating.
through the valve independent of changes in supply pressure,
• Spring return actuators field-configurable for normally open or
eliminating "hunting" by the control system, even at low coil flow.
normally closed fail-safe position.
The pressure regulator virtually eliminates cavitation in the valve,
• Actuators available with optional auxiliary switches.
and decouples the control valve from the effects of piping
• Removable, manual operating handle to control valve during
components such as reducers and elbows.
installation or in an event of power failure.
Pressure independent control valves are sized to match design • Upstream Test Port for venting or pressure gauge attachment.
coil flow regardless of coil size. VRN2 valves eliminate the need to • Three actuator orientations on the valve for cramped spaces.

Dimensions in inches (millimeters)


Valve Type: Dynamic pressure-regulated control valve
E Body Pattern: 2-way, straight-through
Pipe Connection Type: Female-NPT
Controlled Fluid: Chilled or hot water with up to 50% Glycol. Not for
use with steam or fuels.
Valve Action: Quarter-turn rotary
Maximum Safe Operating Pressure: 360 psi (2500 kPa)
Maximum Safe Operating Temperature: 248 F (120 C)
Maximum Close-off Pressure: 100 psid (690 kPa)
F
Fluid Temperature Range: -22 F to 250 F (-30 C to 121 C)
Ambient Temperature Range: 14 F to 131 F (-10 C to 55 C)
Accuracy: ±5% over specified pressure range
Stem Travel: 90 deg. rotation
B
Materials
(Body): Forged Brass ASTM B584
(Seat): Teflon seals/EPDM O-rings
D
(Regulator): Stainless Steel
(Packing): Teflon seals/EPDM O-rings
A (Diaphragm): Hydrogenated Acrylonitrile Butadiene Rubber
C

DIMENSIONS IN INCHES (MM)


VALVE
SIZE (IN.) a a
A B C D E Fz Fs
1/2 5 11/16 4 5/16 8 19/32 1 2 1/2 8 13/32 7 3/16
(145) (109) (218) (26) (64) (213) (182)
3/4
5 29/32 8.7
(150) (221)
1
9 4 19/32 10.9 1 5/8 9 13/32 8 3/16
(229) (117) (277) (41) (239) (207)
1 1/4 8 13/32 10 19/32
(213) (269)
8 3/16 10.5
(208) (267)
1 1/2
10 5 3/16 12 3/32 2 3/32 10 13/32 9 3/16
(254) (132) (307) (53) (264) (232)

2 9 29/32 12
(251) (305)
2 1/2 10 9/32 12 3/16
(263) (310)
3 10 13/16 12.4
(274) (314)
a LONG SHAFT SUPPLIED WITH “ZELIX” (Z) DIRECT COUPLED ACTUATORS;
SHORT SHAFT SUPPLIED WITH “SALT” (S) NON-SPRING RETURN DCAS. M31310

542 customer.honeywell.com 70-6910


Pressure-regulated Control Valves
Flow Characteristics: Equal Percentage with flow control insert

Controls
Home
Comments: 2 - 10V position feedback signal

Valve Size Maximum Flow Minimum head loss Maximum head loss Materials
(Plug/
Product Ball/ Available
Number (inch) (DN) (gpm) (m3/h) (ft) (psi) (kPa) (ft) (psi) (kPa) Disc) (Stem) Includes Accessories

Indoor Air Quality


VRN2AB3D2B 1/2 in. DN15 1.0 gpm 0.23 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
VRN2AB3D2D 1/2 in. DN15 1.0 gpm 0.23 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass MS7505 "Zelix" Modulating w/ position
brass Spring Return DCA feedback signal
VRN2AB3S2B 1/2 in. DN15 1.0 gpm 0.23 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2AB3S2D 1/2 in. DN15 1.0 gpm 0.23 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA

Combustion Controls
VRN2AD3D2B 1/2 in. DN15 2.0 gpm 0.45 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit

Residential
VRN2AD3D2D 1/2 in. DN15 2.0 gpm 0.45 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA
VRN2AD3S2B 1/2 in. DN15 2.0 gpm 0.45 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2AD3S2D 1/2 in. DN15 2.0 gpm 0.45 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
VRN2AE3D2B 1/2 in. DN15 3.0 gpm 0.68 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit

Hydronic Controls
VRN2AE3D2D 1/2 in. DN15 3.0 gpm 0.68 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA
VRN2AE3S2B 1/2 in. DN15 3.0 gpm 0.68 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2AE3S2D 1/2 in. DN15 3.0 gpm 0.68 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
VRN2AF3D2B 1/2 in. DN15 4.0 gpm 0.91 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
VRN2AF3D2D 1/2 in. DN15 4.0 gpm 0.91 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA

Controls
Water
VRN2AF3S2B 1/2 in. DN15 4.0 gpm 0.91 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2AF3S2D 1/2 in. DN15 4.0 gpm 0.91 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
VRN2AG3D2B 1/2 in. DN15 5.0 gpm 1.14 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit

Building Automation
VRN2AG3D2D 1/2 in. DN15 5.0 gpm 1.14 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA
VRN2AG3S2B 1/2 in. DN15 5.0 gpm 1.14 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2AG3S2D 1/2 in. DN15 5.0 gpm 1.14 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
VRN2AH3D2B 1/2 in. DN15 6.0 gpm 1.36 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
VRN2AH3D2D 1/2 in. DN15 6.0 gpm 1.36 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA

Components
Commercial
VRN2AH3S2B 1/2 in. DN15 6.0 gpm 1.36 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2AH3S2D 1/2 in. DN15 6.0 gpm 1.36 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
VRN2AJ3D2B 1/2 in. DN15 7.0 gpm 1.59 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
VRN2AJ3D2D 1/2 in. DN15 7.0 gpm 1.59 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass MS7505 "Zelix" Modulating
Pneumatic Controls

brass Spring Return DCA


VRN2AJ3S2B 1/2 in. DN15 7.0 gpm 1.59 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2AJ3S2D 1/2 in. DN15 7.0 gpm 1.59 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
VRN2BB3D2B 3/4 in. DN20 1.0 gpm 0.23 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
VRN2BB3D2D 3/4 in. DN20 1.0 gpm 0.23 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass MS7505 "Zelix" Modulating
Industrial Combustion

brass Spring Return DCA


VRN2BB3S2B 3/4 in. DN20 1.0 gpm 0.23 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
Controls

70-6910 543
Pressure-regulated Control Valves
Valve Size Maximum Flow Minimum head loss Maximum head loss Materials
(Plug/
Product Ball/ Available
Number (inch) (DN) (gpm) (m3/h) (ft) (psi) (kPa) (ft) (psi) (kPa) Disc) (Stem) Includes Accessories
VRN2BB3S2D 3/4 in. DN20 1.0 gpm 0.23 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
VRN2BD3D2B 3/4 in. DN20 2.0 gpm 0.45 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
VRN2BD3D2D 3/4 in. DN20 2.0 gpm 0.45 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA
VRN2BD3S2B 3/4 in. DN20 2.0 gpm 0.45 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2BD3S2D 3/4 in. DN20 2.0 gpm 0.45 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
VRN2BE3D2B 3/4 in. DN20 3.0 gpm 0.68 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
VRN2BE3D2D 3/4 in. DN20 3.0 gpm 0.68 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA
VRN2BE3S2B 3/4 in. DN20 3.0 gpm 0.68 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2BE3S2D 3/4 in. DN20 3.0 gpm 0.68 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
VRN2BF3D2B 3/4 in. DN20 4.0 gpm 0.91 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
VRN2BF3D2D 3/4 in. DN20 4.0 gpm 0.91 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA
VRN2BF3S2B 3/4 in. DN20 4.0 gpm 0.91 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2BF3S2D 3/4 in. DN20 4.0 gpm 0.91 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
VRN2BG3D2B 3/4 in. DN20 5.0 gpm 1.14 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
VRN2BG3D2D 3/4 in. DN20 5.0 gpm 1.14 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA
VRN2BG3S2B 3/4 in. DN20 5.0 gpm 1.14 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2BG3S2D 3/4 in. DN20 5.0 gpm 1.14 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
VRN2BH3D2B 3/4 in. DN20 6.0 gpm 1.36 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
VRN2BH3D2D 3/4 in. DN20 6.0 gpm 1.36 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA
VRN2BH3S2B 3/4 in. DN20 6.0 gpm 1.36 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2BH3S2D 3/4 in. DN20 6.0 gpm 1.36 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
VRN2BJ3D2B 3/4 in. DN20 7.0 gpm 1.59 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
VRN2BJ3D2D 3/4 in. DN20 7.0 gpm 1.59 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA
VRN2BJ3S2B 3/4 in. DN20 7.0 gpm 1.59 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2BJ3S2D 3/4 in. DN20 7.0 gpm 1.59 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
VRN2BK3D2B 3/4 in. DN20 8.0 gpm 1.82 m3/h 13.1 ft 6.0 psid 41 kPa 76 ft 35 psid 240 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
VRN2BK3D2D 3/4 in. DN20 8.0 gpm 1.82 m3/h 13.1 ft 6.0 psid 41 kPa 76 ft 35 psid 240 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA
VRN2BK3S2B 3/4 in. DN20 8.0 gpm 1.82 m3/h 13.1 ft 6.0 psid 41 kPa 76 ft 35 psid 240 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2BK3S2D 3/4 in. DN20 8.0 gpm 1.82 m3/h 13.1 ft 6.0 psid 41 kPa 76 ft 35 psid 240 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
VRN2BL3D2B 3/4 in. DN20 9.0 gpm 2.04 m3/h 13.1 ft 6.0 psid 41 kPa 76 ft 35 psid 240 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
VRN2BL3D2D 3/4 in. DN20 9.0 gpm 2.04 m3/h 13.1 ft 6.0 psid 41 kPa 76 ft 35 psid 240 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA
VRN2BL3S2B 3/4 in. DN20 9.0 gpm 2.04 m3/h 13.1 ft 6.0 psid 41 kPa 76 ft 35 psid 240 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2BL3S2D 3/4 in. DN20 9.0 gpm 2.04 m3/h 13.1 ft 6.0 psid 41 kPa 76 ft 35 psid 240 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA

544 customer.honeywell.com 70-6910


Pressure-regulated Control Valves

Controls
Valve Size Maximum Flow Minimum head loss Maximum head loss Materials

Home
(Plug/
Product Ball/ Available
Number (inch) (DN) (gpm) (m3/h) (ft) (psi) (kPa) (ft) (psi) (kPa) Disc) (Stem) Includes Accessories
VRN2CB3D2B 1 in. DN25 1.0 gpm 0.23 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
VRN2CB3D2D 1 in. DN25 1.0 gpm 0.23 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass MS7505 "Zelix" Modulating

Indoor Air Quality


brass Spring Return DCA
VRN2CB3S2B 1 in. DN25 1.0 gpm 0.23 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2CB3S2D 1 in. DN25 1.0 gpm 0.23 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
VRN2CD3D2B 1 in. DN25 2.0 gpm 0.45 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
VRN2CD3D2D 1 in. DN25 2.0 gpm 0.45 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass MS7505 "Zelix" Modulating

Combustion Controls
brass Spring Return DCA
VRN2CD3S2B 1 in. DN25 2.0 gpm 0.45 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary

Residential
Steel Steel switch kit
VRN2CD3S2D 1 in. DN25 2.0 gpm 0.45 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
VRN2CE3D2B 1 in. DN25 3.0 gpm 0.68 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
VRN2CE3D2D 1 in. DN25 3.0 gpm 0.68 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA

Hydronic Controls
VRN2CE3S2B 1 in. DN25 3.0 gpm 0.68 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2CE3S2D 1 in. DN25 3.0 gpm 0.68 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
VRN2CF3D2B 1 in. DN25 4.0 gpm 0.91 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
VRN2CF3D2D 1 in. DN25 4.0 gpm 0.91 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA
VRN2CF3S2B 1 in. DN25 4.0 gpm 0.91 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit

Controls
VRN2CF3S2D 1 in. DN25 4.0 gpm 0.91 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless MS7505 "Zelix" Modulating

Water
Steel Steel Spring Return DCA
VRN2CG3D2B 1 in. DN25 5.0 gpm 1.14 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
VRN2CG3D2D 1 in. DN25 5.0 gpm 1.14 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA
VRN2CG3S2B 1 in. DN25 5.0 gpm 1.14 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary

Building Automation
Steel Steel switch kit
VRN2CG3S2D 1 in. DN25 5.0 gpm 1.14 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
VRN2CH3D2B 1 in. DN25 6.0 gpm 1.36 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
VRN2CH3D2D 1 in. DN25 6.0 gpm 1.36 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA
VRN2CH3S2B 1 in. DN25 6.0 gpm 1.36 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit

Components
VRN2CH3S2D 1 in. DN25 6.0 gpm 1.36 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless MS7505 "Zelix" Modulating

Commercial
Steel Steel Spring Return DCA
VRN2CJ3D2B 1 in. DN25 7.0 gpm 1.59 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
VRN2CJ3D2D 1 in. DN25 7.0 gpm 1.59 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA
VRN2CJ3S2B 1 in. DN25 7.0 gpm 1.59 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
Pneumatic Controls

VRN2CJ3S2D 1 in. DN25 7.0 gpm 1.59 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
VRN2CK3D2B 1 in. DN25 8.0 gpm 1.82 m3/h 13.1 ft 6.0 psid 41 kPa 76 ft 35 psid 240 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
VRN2CK3D2D 1 in. DN25 8.0 gpm 1.82 m3/h 13.1 ft 6.0 psid 41 kPa 76 ft 35 psid 240 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA
VRN2CK3S2B 1 in. DN25 8.0 gpm 1.82 m3/h 13.1 ft 6.0 psid 41 kPa 76 ft 35 psid 240 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
Industrial Combustion

VRN2CK3S2D 1 in. DN25 8.0 gpm 1.82 m3/h 13.1 ft 6.0 psid 41 kPa 76 ft 35 psid 240 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
Controls

VRN2CL3D2B 1 in. DN25 9.0 gpm 2.04 m3/h 13.1 ft 6.0 psid 41 kPa 76 ft 35 psid 240 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit

70-6910 545
Pressure-regulated Control Valves
Valve Size Maximum Flow Minimum head loss Maximum head loss Materials
(Plug/
Product Ball/ Available
Number (inch) (DN) (gpm) (m3/h) (ft) (psi) (kPa) (ft) (psi) (kPa) Disc) (Stem) Includes Accessories
VRN2CL3D2D 1 in. DN25 9.0 gpm 2.04 m3/h 13.1 ft 6.0 psid 41 kPa 76 ft 35 psid 240 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA
VRN2CL3S2B 1 in. DN25 9.0 gpm 2.04 m3/h 13.1 ft 6.0 psid 41 kPa 76 ft 35 psid 240 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2CL3S2D 1 in. DN25 9.0 gpm 2.04 m3/h 13.1 ft 6.0 psid 41 kPa 76 ft 35 psid 240 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
VRN2CM3D2B 1 in. DN25 10 gpm 2.27 m3/h 6.5 ft 3.0 psid 21 kPa 109 ft 50 psid 340 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
VRN2CM3D2D 1 in. DN25 10 gpm 2.27 m3/h 6.5 ft 3.0 psid 21 kPa 109 ft 50 psid 340 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA
VRN2CM3S2B 1 in. DN25 10 gpm 2.27 m3/h 6.5 ft 3.0 psid 21 kPa 109 ft 50 psid 340 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2CM3S2D 1 in. DN25 10 gpm 2.27 m3/h 6.5 ft 3.0 psid 21 kPa 109 ft 50 psid 340 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
VRN2CN3D2B 1 in. DN25 15 gpm 3.41 m3/h 6.5 ft 3.0 psid 21 kPa 109 ft 50 psid 340 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
VRN2CN3D2D 1 in. DN25 15 gpm 3.41 m3/h 6.5 ft 3.0 psid 21 kPa 109 ft 50 psid 340 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA
VRN2CN3S2B 1 in. DN25 15 gpm 3.41 m3/h 6.5 ft 3.0 psid 21 kPa 109 ft 50 psid 340 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2CN3S2D 1 in. DN25 15 gpm 3.41 m3/h 6.5 ft 3.0 psid 21 kPa 109 ft 50 psid 340 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
VRN2CP3D2B 1 in. DN25 20 gpm 4.54 m3/h 8.7 ft 4.0 psid 28 kPa 109 ft 50 psid 340 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
VRN2CP3D2D 1 in. DN25 20 gpm 4.54 m3/h 8.7 ft 4.0 psid 28 kPa 109 ft 50 psid 340 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA
VRN2CP3S2B 1 in. DN25 20 gpm 4.54 m3/h 8.7 ft 4.0 psid 28 kPa 109 ft 50 psid 340 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2CP3S2D 1 in. DN25 20 gpm 4.54 m3/h 8.7 ft 4.0 psid 28 kPa 109 ft 50 psid 340 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
VRN2DM3D2B 1-1/4 in. DN32 10 gpm 2.27 m3/h 6.5 ft 3.0 psid 21 kPa 109 ft 50 psid 340 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
VRN2DM3D2D 1-1/4 in. DN32 10 gpm 2.27 m3/h 6.5 ft 3.0 psid 21 kPa 109 ft 50 psid 340 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA
VRN2DM3S2B 1-1/4 in. DN32 10 gpm 2.27 m3/h 6.5 ft 3.0 psid 21 kPa 109 ft 50 psid 340 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2DM3S2D 1-1/4 in. DN32 10 gpm 2.27 m3/h 6.5 ft 3.0 psid 21 kPa 109 ft 50 psid 340 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
VRN2DN3D2B 1-1/4 in. DN32 15 gpm 3.41 m3/h 6.5 ft 3.0 psid 21 kPa 109 ft 50 psid 340 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
VRN2DN3D2D 1-1/4 in. DN32 15 gpm 3.41 m3/h 6.5 ft 3.0 psid 21 kPa 109 ft 50 psid 340 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA
VRN2DN3S2B 1-1/4 in. DN32 15 gpm 3.41 m3/h 6.5 ft 3.0 psid 21 kPa 109 ft 50 psid 340 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2DN3S2D 1-1/4 in. DN32 15 gpm 3.41 m3/h 6.5 ft 3.0 psid 21 kPa 109 ft 50 psid 340 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
VRN2DP3D2B 1-1/4 in. DN32 20 gpm 4.54 m3/h 8.7 ft 4.0 psid 28 kPa 109 ft 50 psid 340 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
VRN2DP3D2D 1-1/4 in. DN32 20 gpm 4.54 m3/h 8.7 ft 4.0 psid 28 kPa 109 ft 50 psid 340 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA
VRN2DP3S2B 1-1/4 in. DN32 20 gpm 4.54 m3/h 8.7 ft 4.0 psid 28 kPa 109 ft 50 psid 340 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2DP3S2D 1-1/4 in. DN32 20 gpm 4.54 m3/h 8.7 ft 4.0 psid 28 kPa 109 ft 50 psid 340 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
VRN2DQ3D2B 1-1/4 in. DN32 25 gpm 5.68 m3/h 10.9 ft 5.0 psid 34 kPa 109 ft 50 psid 340 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
VRN2DQ3D2D 1-1/4 in. DN32 25 gpm 5.68 m3/h 10.9 ft 5.0 psid 34 kPa 109 ft 50 psid 340 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA
VRN2DQ3S2B 1-1/4 in. DN32 25 gpm 5.68 m3/h 10.9 ft 5.0 psid 34 kPa 109 ft 50 psid 340 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2DQ3S2D 1-1/4 in. DN32 25 gpm 5.68 m3/h 10.9 ft 5.0 psid 34 kPa 109 ft 50 psid 340 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
VRN2DR3D2B 1-1/4 in. DN32 30 gpm 6.81 m3/h 10.9 ft 5.0 psid 34 kPa 109 ft 50 psid 340 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
VRN2DR3D2D 1-1/4 in. DN32 30 gpm 6.81 m3/h 10.9 ft 5.0 psid 34 kPa 109 ft 50 psid 340 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA

546 customer.honeywell.com 70-6910


Pressure-regulated Control Valves

Controls
Valve Size Maximum Flow Minimum head loss Maximum head loss Materials

Home
(Plug/
Product Ball/ Available
Number (inch) (DN) (gpm) (m3/h) (ft) (psi) (kPa) (ft) (psi) (kPa) Disc) (Stem) Includes Accessories
VRN2DR3S2B 1-1/4 in. DN32 30 gpm 6.81 m3/h 10.9 ft 5.0 psid 34 kPa 109 ft 50 psid 340 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2DR3S2D 1-1/4 in. DN32 30 gpm 6.81 m3/h 10.9 ft 5.0 psid 34 kPa 109 ft 50 psid 340 kPa Stainless Stainless MS7505 "Zelix" Modulating

Indoor Air Quality


Steel Steel Spring Return DCA
VRN2EU3D2B 1-1/2 in. DN40 45 gpm 10 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
VRN2EU3D2D 1-1/2 in. DN40 45 gpm 10 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA
VRN2EU3S2B 1-1/2 in. DN40 45 gpm 10 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2EU3S2D 1-1/2 in. DN40 45 gpm 10 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Stainless Stainless MS7505 "Zelix" Modulating

Combustion Controls
Steel Steel Spring Return DCA
VRN2E13D2B 1-1/2 in. DN40 50 gpm 11 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary

Residential
brass switch kit
VRN2E13D2D 1-1/2 in. DN40 50 gpm 11 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA
VRN2E13S2B 1-1/2 in. DN40 50 gpm 11 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2E13S2D 1-1/2 in. DN40 50 gpm 11 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA

Hydronic Controls
VRN2EM3D2B 1-1/2 in. DN40 10 gpm 2.27 m3/h 6.5 ft 3.0 psid 21 kPa 109 ft 50 psid 340 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
VRN2EM3D2D 1-1/2 in. DN40 10 gpm 2.27 m3/h 6.5 ft 3.0 psid 21 kPa 109 ft 50 psid 340 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA
VRN2EM3S2B 1-1/2 in. DN40 10 gpm 2.27 m3/h 6.5 ft 3.0 psid 21 kPa 109 ft 50 psid 340 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2EM3S2D 1-1/2 in. DN40 10 gpm 2.27 m3/h 6.5 ft 3.0 psid 21 kPa 109 ft 50 psid 340 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
VRN2EN3D2B 1-1/2 in. DN40 15 gpm 3.41 m3/h 6.5 ft 3.0 psid 21 kPa 109 ft 50 psid 340 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit

Controls
VRN2EN3D2D 1-1/2 in. DN40 15 gpm 3.41 m3/h 6.5 ft 3.0 psid 21 kPa 109 ft 50 psid 340 kPa Plated Brass MS7505 "Zelix" Modulating

Water
brass Spring Return DCA
VRN2EN3S2B 1-1/2 in. DN40 15 gpm 3.41 m3/h 6.5 ft 3.0 psid 21 kPa 109 ft 50 psid 340 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2EN3S2D 1-1/2 in. DN40 15 gpm 3.41 m3/h 6.5 ft 3.0 psid 21 kPa 109 ft 50 psid 340 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
VRN2EP3D2B 1-1/2 in. DN40 20 gpm 4.54 m3/h 8.7 ft 4.0 psid 28 kPa 109 ft 50 psid 340 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary

Building Automation
brass switch kit
VRN2EP3D2D 1-1/2 in. DN40 20 gpm 4.54 m3/h 8.7 ft 4.0 psid 28 kPa 109 ft 50 psid 340 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA
VRN2EP3S2B 1-1/2 in. DN40 20 gpm 4.54 m3/h 8.7 ft 4.0 psid 28 kPa 109 ft 50 psid 340 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2EP3S2D 1-1/2 in. DN40 20 gpm 4.54 m3/h 8.7 ft 4.0 psid 28 kPa 109 ft 50 psid 340 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
VRN2EQ3D2B 1-1/2 in. DN40 25 gpm 5.68 m3/h 10.9 ft 5.0 psid 34 kPa 109 ft 50 psid 340 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit

Components
VRN2EQ3D2D 1-1/2 in. DN40 25 gpm 5.68 m3/h 10.9 ft 5.0 psid 34 kPa 109 ft 50 psid 340 kPa Plated Brass MS7505 "Zelix" Modulating

Commercial
brass Spring Return DCA
VRN2EQ3S2B 1-1/2 in. DN40 25 gpm 5.68 m3/h 10.9 ft 5.0 psid 34 kPa 109 ft 50 psid 340 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2EQ3S2D 1-1/2 in. DN40 25 gpm 5.68 m3/h 10.9 ft 5.0 psid 34 kPa 109 ft 50 psid 340 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
VRN2ER3D2B 1-1/2 in. DN40 30 gpm 6.81 m3/h 10.9 ft 5.0 psid 34 kPa 109 ft 50 psid 340 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
Pneumatic Controls

VRN2ER3D2D 1-1/2 in. DN40 30 gpm 6.81 m3/h 10.9 ft 5.0 psid 34 kPa 109 ft 50 psid 340 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA
VRN2ER3S2B 1-1/2 in. DN40 30 gpm 6.81 m3/h 10.9 ft 5.0 psid 34 kPa 109 ft 50 psid 340 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2ER3S2D 1-1/2 in. DN40 30 gpm 6.81 m3/h 10.9 ft 5.0 psid 34 kPa 109 ft 50 psid 340 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
VRN2ES3D2B 1-1/2 in. DN40 35 gpm 7.95 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
Industrial Combustion

VRN2ES3D2D 1-1/2 in. DN40 35 gpm 7.95 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA
Controls

VRN2ES3S2B 1-1/2 in. DN40 35 gpm 7.95 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit

70-6910 547
Pressure-regulated Control Valves
Valve Size Maximum Flow Minimum head loss Maximum head loss Materials
(Plug/
Product Ball/ Available
Number (inch) (DN) (gpm) (m3/h) (ft) (psi) (kPa) (ft) (psi) (kPa) Disc) (Stem) Includes Accessories
VRN2ES3S2D 1-1/2 in. DN40 35 gpm 7.95 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
VRN2ET3D2B 1-1/2 in. DN40 40 gpm 9.08 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
VRN2ET3D2D 1-1/2 in. DN40 40 gpm 9.08 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA
VRN2ET3S2B 1-1/2 in. DN40 40 gpm 9.08 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2ET3S2D 1-1/2 in. DN40 40 gpm 9.08 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
VRN2FQ3D2B 2 in. DN50 25 gpm 5.68 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
VRN2FQ3D2D 2 in. DN50 25 gpm 5.68 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA
VRN2FQ3S2B 2 in. DN50 25 gpm 5.68 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2FQ3S2D 2 in. DN50 25 gpm 5.68 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
VRN2FR3D2B 2 in. DN50 30 gpm 6.81 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
VRN2FR3D2D 2 in. DN50 30 gpm 6.81 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA
VRN2FR3S2B 2 in. DN50 30 gpm 6.81 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2FR3S2D 2 in. DN50 30 gpm 6.81 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
VRN2FS3D2B 2 in. DN50 35 gpm 7.95 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
VRN2FS3D2D 2 in. DN50 35 gpm 7.95 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA
VRN2FS3S2B 2 in. DN50 35 gpm 7.95 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2FS3S2D 2 in. DN50 35 gpm 7.95 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
VRN2FT3D2B 2 in. DN50 40 gpm 9.08 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
VRN2FT3D2D 2 in. DN50 40 gpm 9.08 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA
VRN2FT3S2B 2 in. DN50 40 gpm 9.08 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2FT3S2D 2 in. DN50 40 gpm 9.08 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
VRN2FU3D2B 2 in. DN50 45 gpm 10 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
VRN2FU3D2D 2 in. DN50 45 gpm 10 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA
VRN2FU3S2B 2 in. DN50 45 gpm 10 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2FU3S2D 2 in. DN50 45 gpm 10 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
VRN2F13D2B 2 in. DN50 50 gpm 11 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
VRN2F13D2D 2 in. DN50 50 gpm 11 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA
VRN2F13S2B 2 in. DN50 50 gpm 11 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2F13S2D 2 in. DN50 50 gpm 11 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
VRN2F23D2B 2 in. DN50 55 gpm 12 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
VRN2F23D2D 2 in. DN50 55 gpm 12 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA
VRN2F23S2B 2 in. DN50 55 gpm 12 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2F23S2D 2 in. DN50 55 gpm 12 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA

548 customer.honeywell.com 70-6910


Pressure-regulated Control Valves

Controls
Valve Size Maximum Flow Minimum head loss Maximum head loss Materials

Home
(Plug/
Product Ball/ Available
Number (inch) (DN) (gpm) (m3/h) (ft) (psi) (kPa) (ft) (psi) (kPa) Disc) (Stem) Includes Accessories
VRN2F33D2B 2 in. DN50 60 gpm 14 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
VRN2F33D2D 2 in. DN50 60 gpm 14 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Plated Brass MS7505 "Zelix" Modulating

Indoor Air Quality


brass Spring Return DCA
VRN2F33S2B 2 in. DN50 60 gpm 14 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2F33S2D 2 in. DN50 60 gpm 14 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
VRN2F43D2B 2 in. DN50 65 gpm 15 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
VRN2F43D2D 2 in. DN50 65 gpm 15 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Plated Brass MS7505 "Zelix" Modulating

Combustion Controls
brass Spring Return DCA
VRN2F43S2B 2 in. DN50 65 gpm 15 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary

Residential
Steel Steel switch kit
VRN2F43S2D 2 in. DN50 65 gpm 15 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
VRN2F53D2B 2 in. DN50 70 gpm 16 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
VRN2F53D2D 2 in. DN50 70 gpm 16 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA

Hydronic Controls
VRN2F53S2B 2 in. DN50 70 gpm 16 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2F53S2D 2 in. DN50 70 gpm 16 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
VRN2F63D2B 2 in. DN50 75 gpm 17 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
VRN2F63D2D 2 in. DN50 75 gpm 17 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA
VRN2F63S2B 2 in. DN50 75 gpm 17 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit

Controls
VRN2F63S2D 2 in. DN50 75 gpm 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Stainless Stainless MS7505 "Zelix" Modulating

Water
17 m3/h
Steel Steel Spring Return DCA
VRN2GQ3D2B 2-1/2 in. DN65 25 gpm 5.68 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
VRN2GQ3D2D 2-1/2 in. DN65 25 gpm 5.68 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA
VRN2GQ3S2B 2-1/2 in. DN65 25 gpm 5.68 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary

Building Automation
Steel Steel switch kit
VRN2GQ3S2D 2-1/2 in. DN65 25 gpm 5.68 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
VRN2GR3D2B 2-1/2 in. DN65 30 gpm 6.81 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
VRN2GR3D2D 2-1/2 in. DN65 30 gpm 6.81 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA
VRN2GR3S2B 2-1/2 in. DN65 30 gpm 6.81 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit

Components
VRN2GR3S2D 2-1/2 in. DN65 30 gpm 6.81 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Stainless Stainless MS7505 "Zelix" Modulating

Commercial
Steel Steel Spring Return DCA
VRN2GS3D2B 2-1/2 in. DN65 35 gpm 7.95 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
VRN2GS3D2D 2-1/2 in. DN65 35 gpm 7.95 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA
VRN2GS3S2B 2-1/2 in. DN65 35 gpm 7.95 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
Pneumatic Controls

VRN2GS3S2D 2-1/2 in. DN65 35 gpm 7.95 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
VRN2GT3D2B 2-1/2 in. DN65 40 gpm 9.08 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
VRN2GT3D2D 2-1/2 in. DN65 40 gpm 9.08 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA
VRN2GT3S2B 2-1/2 in. DN65 40 gpm 9.08 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
Industrial Combustion

VRN2GT3S2D 2-1/2 in. DN65 40 gpm 9.08 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
Controls

VRN2GU3D2B 2-1/2 in. DN65 45 gpm 10 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit

70-6910 549
Pressure-regulated Control Valves
Valve Size Maximum Flow Minimum head loss Maximum head loss Materials
(Plug/
Product Ball/ Available
Number (inch) (DN) (gpm) (m3/h) (ft) (psi) (kPa) (ft) (psi) (kPa) Disc) (Stem) Includes Accessories
VRN2GU3D2D 2-1/2 in. DN65 45 gpm 10 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA
VRN2GU3S2B 2-1/2 in. DN65 45 gpm 10 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2GU3S2D 2-1/2 in. DN65 45 gpm 10 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
VRN2G13D2B 2-1/2 in. DN65 50 gpm 11 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
VRN2G13D2D 2-1/2 in. DN65 50 gpm 11 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA
VRN2G13S2B 2-1/2 in. DN65 50 gpm 11 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2G13S2D 2-1/2 in. DN65 50 gpm 11 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
VRN2G23D2B 2-1/2 in. DN65 55 gpm 12 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
VRN2G23D2D 2-1/2 in. DN65 55 gpm 12 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA
VRN2G23S2B 2-1/2 in. DN65 55 gpm 12 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2G23S2D 2-1/2 in. DN65 55 gpm 12 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
VRN2G33D2B 2-1/2 in. DN65 60 gpm 14 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
VRN2G33D2D 2-1/2 in. DN65 60 gpm 14 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA
VRN2G33S2B 2-1/2 in. DN65 60 gpm 14 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2G33S2D 2-1/2 in. DN65 60 gpm 14 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
VRN2G43D2B 2-1/2 in. DN65 65 gpm 15 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
VRN2G43D2D 2-1/2 in. DN65 65 gpm 15 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA
VRN2G43S2B 2-1/2 in. DN65 65 gpm 15 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2G43S2D 2-1/2 in. DN65 65 gpm 15 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
VRN2G53D2B 2-1/2 in. DN65 70 gpm 16 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
VRN2G53D2D 2-1/2 in. DN65 70 gpm 16 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA
VRN2G53S2B 2-1/2 in. DN65 70 gpm 16 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2G53S2D 2-1/2 in. DN65 70 gpm 16 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
VRN2G63D2B 2-1/2 in. DN65 75 gpm 17 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
VRN2G63D2D 2-1/2 in. DN65 75 gpm 17 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA
VRN2G63S2B 2-1/2 in. DN65 75 gpm 17 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2G63S2D 2-1/2 in. DN65 75 gpm 17 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
VRN2G73D2B 2-1/2 in. DN65 80 gpm 18 m3/h 21.8 ft 10.0 psid 69 kPa 126 ft 58 psid 400 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
VRN2G73D2D 2-1/2 in. DN65 80 gpm 18 m3/h 21.8 ft 10.0 psid 69 kPa 126 ft 58 psid 400 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA
VRN2G73S2B 2-1/2 in. DN65 80 gpm 18 m3/h 21.8 ft 10.0 psid 69 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2G73S2D 2-1/2 in. DN65 80 gpm 18 m3/h 21.8 ft 10.0 psid 69 kPa 126 ft 58 psid 400 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
VRN2G83D2B 2-1/2 in. DN65 85 gpm 19 m3/h 21.8 ft 10.0 psid 69 kPa 126 ft 58 psid 400 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
VRN2G83D2D 2-1/2 in. DN65 85 gpm 19 m3/h 21.8 ft 10.0 psid 69 kPa 126 ft 58 psid 400 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA

550 customer.honeywell.com 70-6910


Pressure-regulated Control Valves

Controls
Valve Size Maximum Flow Minimum head loss Maximum head loss Materials

Home
(Plug/
Product Ball/ Available
Number (inch) (DN) (gpm) (m3/h) (ft) (psi) (kPa) (ft) (psi) (kPa) Disc) (Stem) Includes Accessories
VRN2G83S2B 2-1/2 in. DN65 85 gpm 19 m3/h 21.8 ft 10.0 psid 69 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2G83S2D 2-1/2 in. DN65 85 gpm 19 m3/h 21.8 ft 10.0 psid 69 kPa 126 ft 58 psid 400 kPa Stainless Stainless MS7505 "Zelix" Modulating

Indoor Air Quality


Steel Steel Spring Return DCA
VRN2HQ3D2B 3 in. DN80 25 gpm 5.68 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
VRN2HQ3D2D 3 in. DN80 25 gpm 5.68 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA
VRN2HQ3S2B 3 in. DN80 25 gpm 5.68 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2HQ3S2D 3 in. DN80 25 gpm 5.68 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Stainless Stainless MS7505 "Zelix" Modulating

Combustion Controls
Steel Steel Spring Return DCA
VRN2HR3D2B 3 in. DN80 30 gpm 6.81 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary

Residential
brass switch kit
VRN2HR3D2D 3 in. DN80 30 gpm 6.81 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA
VRN2HR3S2B 3 in. DN80 30 gpm 6.81 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2HR3S2D 3 in. DN80 30 gpm 6.81 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA

Hydronic Controls
VRN2HS3D2B 3 in. DN80 35 gpm 7.95 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
VRN2HS3D2D 3 in. DN80 35 gpm 7.95 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA
VRN2HS3S2B 3 in. DN80 35 gpm 7.95 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2HS3S2D 3 in. DN80 35 gpm 7.95 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
VRN2HT3D2B 3 in. DN80 40 gpm 9.08 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit

Controls
VRN2HT3D2D 3 in. DN80 40 gpm 9.08 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Plated Brass MS7505 "Zelix" Modulating

Water
brass Spring Return DCA
VRN2HT3S2B 3 in. DN80 40 gpm 9.08 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2HT3S2D 3 in. DN80 40 gpm 9.08 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
VRN2HU3D2B 3 in. DN80 45 gpm 10 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary

Building Automation
brass switch kit
VRN2HU3D2D 3 in. DN80 45 gpm 10 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA
VRN2HU3S2B 3 in. DN80 45 gpm 10 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2HU3S2D 3 in. DN80 45 gpm 10 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
VRN2H13D2B 3 in. DN80 50 gpm 11 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit

Components
VRN2H13D2D 3 in. DN80 50 gpm 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Plated Brass MS7505 "Zelix" Modulating

Commercial
11 m3/h
brass Spring Return DCA
VRN2H13S2B 3 in. DN80 50 gpm 11 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2H13S2D 3 in. DN80 50 gpm 11 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
VRN2H23D2B 3 in. DN80 55 gpm 12 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
Pneumatic Controls

VRN2H23D2D 3 in. DN80 55 gpm 12 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA
VRN2H23S2B 3 in. DN80 55 gpm 12 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2H23S2D 3 in. DN80 55 gpm 12 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
VRN2H33D2B 3 in. DN80 60 gpm 14 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
Industrial Combustion

VRN2H33D2D 3 in. DN80 60 gpm 14 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA
Controls

VRN2H33S2B 3 in. DN80 60 gpm 14 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit

70-6910 551
Pressure-regulated Control Valves
Valve Size Maximum Flow Minimum head loss Maximum head loss Materials
(Plug/
Product Ball/ Available
Number (inch) (DN) (gpm) (m3/h) (ft) (psi) (kPa) (ft) (psi) (kPa) Disc) (Stem) Includes Accessories
VRN2H33S2D 3 in. DN80 60 gpm 14 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
VRN2H43D2B 3 in. DN80 65 gpm 15 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
VRN2H43D2D 3 in. DN80 65 gpm 15 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA
VRN2H43S2B 3 in. DN80 65 gpm 15 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2H43S2D 3 in. DN80 65 gpm 15 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
VRN2H53D2B 3 in. DN80 70 gpm 16 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
VRN2H53D2D 3 in. DN80 70 gpm 16 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA
VRN2H53S2B 3 in. DN80 70 gpm 16 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2H53S2D 3 in. DN80 70 gpm 16 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
VRN2H63D2B 3 in. DN80 75 gpm 17 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
VRN2H63D2D 3 in. DN80 75 gpm 17 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA
VRN2H63S2B 3 in. DN80 75 gpm 17 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2H63S2D 3 in. DN80 75 gpm 17 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
VRN2H73D2B 3 in. DN80 80 gpm 18 m3/h 21.8 ft 10.0 psid 69 kPa 126 ft 58 psid 400 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
VRN2H73D2D 3 in. DN80 80 gpm 18 m3/h 21.8 ft 10.0 psid 69 kPa 126 ft 58 psid 400 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA
VRN2H73S2B 3 in. DN80 80 gpm 18 m3/h 21.8 ft 10.0 psid 69 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2H73S2D 3 in. DN80 80 gpm 18 m3/h 21.8 ft 10.0 psid 69 kPa 126 ft 58 psid 400 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
VRN2H83D2B 3 in. DN80 85 gpm 19 m3/h 21.8 ft 10.0 psid 69 kPa 126 ft 58 psid 400 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
VRN2H83D2D 3 in. DN80 85 gpm 19 m3/h 21.8 ft 10.0 psid 69 kPa 126 ft 58 psid 400 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA
VRN2H83S2B 3 in. DN80 85 gpm 19 m3/h 21.8 ft 10.0 psid 69 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2H83S2D 3 in. DN80 85 gpm 19 m3/h 21.8 ft 10.0 psid 69 kPa 126 ft 58 psid 400 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
Comments: No feedback signal

Valve Size Maximum Flow Minimum head loss Maximum head loss Materials
(Plug/
Ball/ Available
3/
Product Number (inch) (DN) (gpm) (m h) (ft) (psi) (kPa) (ft) (psi) (kPa) Disc) (Stem) Includes Accessories
VRN2AB3D2A 1/2 in. DN15 1.0 gpm 0.23 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit
VRN2AB3DFX 1/2 in. DN15 1.0 gpm 0.23 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque
VRN2AB3S2A 1/2 in. DN15 1.0 gpm 0.23 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2AB3SFX 1/2 in. DN15 1.0 gpm 0.23 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 35 lb-in torque
VRN2AD3D2A 1/2 in. DN15 2.0 gpm 0.45 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit
VRN2AD3DFX 1/2 in. DN15 2.0 gpm 0.45 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque
VRN2AD3S2A 1/2 in. DN15 2.0 gpm 0.45 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2AD3SFX 1/2 in. DN15 2.0 gpm 0.45 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 35 lb-in torque
VRN2AE3D2A 1/2 in. DN15 3.0 gpm 0.68 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit

552 customer.honeywell.com 70-6910


Pressure-regulated Control Valves

Controls
Valve Size Maximum Flow Minimum head loss Maximum head loss Materials

Home
(Plug/
Ball/ Available
Product Number (inch) (DN) (gpm) (m3/h) (ft) (psi) (kPa) (ft) (psi) (kPa) Disc) (Stem) Includes Accessories
VRN2AE3DFX 1/2 in. DN15 3.0 gpm 0.68 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque
VRN2AE3S2A 1/2 in. DN15 3.0 gpm 0.68 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary

Indoor Air Quality


Steel Steel switch kit
VRN2AE3SFX 1/2 in. DN15 3.0 gpm 0.68 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 35 lb-in torque
VRN2AF3D2A 1/2 in. DN15 4.0 gpm 0.91 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit
VRN2AF3DFX 1/2 in. DN15 4.0 gpm 0.91 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque
VRN2AF3S2A 1/2 in. DN15 4.0 gpm 0.91 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary

Combustion Controls
Steel Steel switch kit
VRN2AF3SFX 1/2 in. DN15 4.0 gpm 0.91 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless Two shafts, universal DCA, minimum

Residential
Steel Steel anti-rotation bar 35 lb-in torque
VRN2AG3D2A 1/2 in. DN15 5.0 gpm 1.14 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit
VRN2AG3DFX 1/2 in. DN15 5.0 gpm 1.14 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque
VRN2AG3S2A 1/2 in. DN15 5.0 gpm 1.14 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit

Hydronic Controls
VRN2AG3SFX 1/2 in. DN15 5.0 gpm 1.14 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 35 lb-in torque
VRN2AH3D2A 1/2 in. DN15 6.0 gpm 1.36 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit
VRN2AH3DFX 1/2 in. DN15 6.0 gpm 1.36 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque
VRN2AH3S2A 1/2 in. DN15 6.0 gpm 1.36 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2AH3SFX 1/2 in. DN15 6.0 gpm 1.36 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 35 lb-in torque

Controls
VRN2AJ3D2A 1/2 in. DN15 7.0 gpm 1.59 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary

Water
brass switch kit
VRN2AJ3DFX 1/2 in. DN15 7.0 gpm 1.59 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque
VRN2AJ3S2A 1/2 in. DN15 7.0 gpm 1.59 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2AJ3SFX 1/2 in. DN15 7.0 gpm 1.59 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless Two shafts, universal DCA, minimum

Building Automation
Steel Steel anti-rotation bar 35 lb-in torque
VRN2BB3D2A 3/4 in. DN20 1.0 gpm 0.23 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit
VRN2BB3DFX 3/4 in. DN20 1.0 gpm 0.23 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque
VRN2BB3S2A 3/4 in. DN20 1.0 gpm 0.23 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2BB3SFX 3/4 in. DN20 1.0 gpm 0.23 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 35 lb-in torque

Components
VRN2BD3D2A 3/4 in. DN20 2.0 gpm 0.45 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary

Commercial
brass switch kit
VRN2BD3DFX 3/4 in. DN20 2.0 gpm 0.45 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque
VRN2BD3S2A 3/4 in. DN20 2.0 gpm 0.45 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2BD3SFX 3/4 in. DN20 2.0 gpm 0.45 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 35 lb-in torque
Pneumatic Controls

VRN2BE3D2A 3/4 in. DN20 3.0 gpm 0.68 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit
VRN2BE3DFX 3/4 in. DN20 3.0 gpm 0.68 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque
VRN2BE3S2A 3/4 in. DN20 3.0 gpm 0.68 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2BE3SFX 3/4 in. DN20 3.0 gpm 0.68 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 35 lb-in torque
Industrial Combustion

VRN2BF3D2A 3/4 in. DN20 4.0 gpm 0.91 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit
Controls

VRN2BF3DFX 3/4 in. DN20 4.0 gpm 0.91 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque

70-6910 553
Pressure-regulated Control Valves
Valve Size Maximum Flow Minimum head loss Maximum head loss Materials
(Plug/
Ball/ Available
Product Number (inch) (DN) (gpm) (m3/h) (ft) (psi) (kPa) (ft) (psi) (kPa) Disc) (Stem) Includes Accessories
VRN2BF3S2A 3/4 in. DN20 4.0 gpm 0.91 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2BF3SFX 3/4 in. DN20 4.0 gpm 0.91 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 35 lb-in torque
VRN2BG3D2A 3/4 in. DN20 5.0 gpm 1.14 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit
VRN2BG3DFX 3/4 in. DN20 5.0 gpm 1.14 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque
VRN2BG3S2A 3/4 in. DN20 5.0 gpm 1.14 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2BG3SFX 3/4 in. DN20 5.0 gpm 1.14 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 35 lb-in torque
VRN2BH3D2A 3/4 in. DN20 6.0 gpm 1.36 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit
VRN2BH3DFX 3/4 in. DN20 6.0 gpm 1.36 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque
VRN2BH3S2A 3/4 in. DN20 6.0 gpm 1.36 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2BH3SFX 3/4 in. DN20 6.0 gpm 1.36 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 35 lb-in torque
VRN2BJ3D2A 3/4 in. DN20 7.0 gpm 1.59 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit
VRN2BJ3DFX 3/4 in. DN20 7.0 gpm 1.59 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque
VRN2BJ3S2A 3/4 in. DN20 7.0 gpm 1.59 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2BJ3SFX 3/4 in. DN20 7.0 gpm 1.59 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 35 lb-in torque
VRN2BK3D2A 3/4 in. DN20 8.0 gpm 1.82 m3/h 13.1 ft 6.0 psid 41 kPa 76 ft 35 psid 240 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit
VRN2BK3DFX 3/4 in. DN20 8.0 gpm 1.82 m3/h 13.1 ft 6.0 psid 41 kPa 76 ft 35 psid 240 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque
VRN2BK3S2A 3/4 in. DN20 8.0 gpm 1.82 m3/h 13.1 ft 6.0 psid 41 kPa 76 ft 35 psid 240 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2BK3SFX 3/4 in. DN20 8.0 gpm 1.82 m3/h 13.1 ft 6.0 psid 41 kPa 76 ft 35 psid 240 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 35 lb-in torque
VRN2BL3D2A 3/4 in. DN20 9.0 gpm 2.04 m3/h 13.1 ft 6.0 psid 41 kPa 76 ft 35 psid 240 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit
VRN2BL3DFX 3/4 in. DN20 9.0 gpm 2.04 m3/h 13.1 ft 6.0 psid 41 kPa 76 ft 35 psid 240 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque
VRN2BL3S2A 3/4 in. DN20 9.0 gpm 2.04 m3/h 13.1 ft 6.0 psid 41 kPa 76 ft 35 psid 240 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2BL3SFX 3/4 in. DN20 9.0 gpm 2.04 m3/h 13.1 ft 6.0 psid 41 kPa 76 ft 35 psid 240 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 27 lb-in torque
VRN2CB3D2A 1 in. DN25 1.0 gpm 0.23 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit
VRN2CB3DFX 1 in. DN25 1.0 gpm 0.23 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 27 lb-in torque
VRN2CB3S2A 1 in. DN25 1.0 gpm 0.23 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2CB3SFX 1 in. DN25 1.0 gpm 0.23 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 27 lb-in torque
VRN2CD3D2A 1 in. DN25 2.0 gpm 0.45 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit
VRN2CD3DFX 1 in. DN25 2.0 gpm 0.45 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 27 lb-in torque
VRN2CD3S2A 1 in. DN25 2.0 gpm 0.45 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2CD3SFX 1 in. DN25 2.0 gpm 0.45 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 27 lb-in torque
VRN2CE3D2A 1 in. DN25 3.0 gpm 0.68 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit
VRN2CE3DFX 1 in. DN25 3.0 gpm 0.68 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 27 lb-in torque
VRN2CE3S2A 1 in. DN25 3.0 gpm 0.68 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit

554 customer.honeywell.com 70-6910


Pressure-regulated Control Valves

Controls
Valve Size Maximum Flow Minimum head loss Maximum head loss Materials

Home
(Plug/
Ball/ Available
Product Number (inch) (DN) (gpm) (m3/h) (ft) (psi) (kPa) (ft) (psi) (kPa) Disc) (Stem) Includes Accessories
VRN2CE3SFX 1 in. DN25 3.0 gpm 0.68 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 27 lb-in torque
VRN2CF3D2A 1 in. DN25 4.0 gpm 0.91 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary

Indoor Air Quality


brass switch kit
VRN2CF3DFX 1 in. DN25 4.0 gpm 0.91 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 27 lb-in torque
VRN2CF3S2A 1 in. DN25 4.0 gpm 0.91 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2CF3SFX 1 in. DN25 4.0 gpm 0.91 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 27 lb-in torque
VRN2CG3D2A 1 in. DN25 5.0 gpm 1.14 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary

Combustion Controls
brass switch kit
VRN2CG3DFX 1 in. DN25 5.0 gpm 1.14 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass Two shafts, universal DCA, minimum

Residential
brass anti-rotation bar 27 lb-in torque
VRN2CG3S2A 1 in. DN25 5.0 gpm 1.14 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2CG3SFX 1 in. DN25 5.0 gpm 1.14 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 27 lb-in torque
VRN2CH3D2A 1 in. DN25 6.0 gpm 1.36 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit

Hydronic Controls
VRN2CH3DFX 1 in. DN25 6.0 gpm 1.36 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 27 lb-in torque
VRN2CH3S2A 1 in. DN25 6.0 gpm 1.36 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2CH3SFX 1 in. DN25 6.0 gpm 1.36 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 27 lb-in torque
VRN2CJ3D2A 1 in. DN25 7.0 gpm 1.59 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit
VRN2CJ3DFX 1 in. DN25 7.0 gpm 1.59 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 27 lb-in torque

Controls
VRN2CJ3S2A 1 in. DN25 7.0 gpm 1.59 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary

Water
Steel Steel switch kit
VRN2CJ3SFX 1 in. DN25 7.0 gpm 1.59 m3/h 6.5 ft 3.0 psid 21 kPa 76 ft 35 psid 240 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 27 lb-in torque
VRN2CK3D2A 1 in. DN25 8.0 gpm 1.82 m3/h 13.1 ft 6.0 psid 41 kPa 76 ft 35 psid 240 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit
VRN2CK3DFX 1 in. DN25 8.0 gpm 1.82 m3/h 13.1 ft 6.0 psid 41 kPa 76 ft 35 psid 240 kPa Plated Brass Two shafts, universal DCA, minimum

Building Automation
brass anti-rotation bar 27 lb-in torque
VRN2CK3S2A 1 in. DN25 8.0 gpm 1.82 m3/h 13.1 ft 6.0 psid 41 kPa 76 ft 35 psid 240 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2CK3SFX 1 in. DN25 8.0 gpm 1.82 m3/h 13.1 ft 6.0 psid 41 kPa 76 ft 35 psid 240 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 27 lb-in torque
VRN2CL3D2A 1 in. DN25 9.0 gpm 2.04 m3/h 13.1 ft 6.0 psid 41 kPa 76 ft 35 psid 240 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit
VRN2CL3DFX 1 in. DN25 9.0 gpm 2.04 m3/h 13.1 ft 6.0 psid 41 kPa 76 ft 35 psid 240 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 27 lb-in torque

Components
VRN2CL3S2A 1 in. DN25 9.0 gpm 2.04 m3/h 13.1 ft 6.0 psid 41 kPa 76 ft 35 psid 240 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary

Commercial
Steel Steel switch kit
VRN2CL3SFX 1 in. DN25 9.0 gpm 2.04 m3/h 13.1 ft 6.0 psid 41 kPa 76 ft 35 psid 240 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 27 lb-in torque
VRN2CM3D2A 1 in. DN25 10 gpm 2.27 m3/h 6.5 ft 3.0 psid 21 kPa 109 ft 50 psid 340 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit
VRN2CM3DFX 1 in. DN25 10 gpm 2.27 m3/h 6.5 ft 3.0 psid 21 kPa 109 ft 50 psid 340 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque
Pneumatic Controls

VRN2CM3S2A 1 in. DN25 10 gpm 2.27 m3/h 6.5 ft 3.0 psid 21 kPa 109 ft 50 psid 340 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2CM3SFX 1 in. DN25 10 gpm 2.27 m3/h 6.5 ft 3.0 psid 21 kPa 109 ft 50 psid 340 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 35 lb-in torque
VRN2CN3D2A 1 in. DN25 15 gpm 3.41 m3/h 6.5 ft 3.0 psid 21 kPa 109 ft 50 psid 340 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit
VRN2CN3DFX 1 in. DN25 15 gpm 3.41 m3/h 6.5 ft 3.0 psid 21 kPa 109 ft 50 psid 340 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque
Industrial Combustion

VRN2CN3S2A 1 in. DN25 15 gpm 3.41 m3/h 6.5 ft 3.0 psid 21 kPa 109 ft 50 psid 340 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit
Controls

VRN2CN3SFX 1 in. DN25 15 gpm 3.41 m3/h 6.5 ft 3.0 psid 21 kPa 109 ft 50 psid 340 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 35 lb-in torque

70-6910 555
Pressure-regulated Control Valves
Valve Size Maximum Flow Minimum head loss Maximum head loss Materials
(Plug/
Ball/ Available
Product Number (inch) (DN) (gpm) (m3/h) (ft) (psi) (kPa) (ft) (psi) (kPa) Disc) (Stem) Includes Accessories
VRN2CP3D2A 1 in. DN25 20 gpm 4.54 m3/h 8.7 ft 4.0 psid 28 kPa 109 ft 50 psid 340 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit
VRN2CP3DFX 1 in. DN25 20 gpm 4.54 m3/h 8.7 ft 4.0 psid 28 kPa 109 ft 50 psid 340 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque
VRN2CP3S2A 1 in. DN25 20 gpm 4.54 m3/h 8.7 ft 4.0 psid 28 kPa 109 ft 50 psid 340 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2CP3SFX 1 in. DN25 20 gpm 4.54 m3/h 8.7 ft 4.0 psid 28 kPa 109 ft 50 psid 340 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 35 lb-in torque
VRN2DM3D2A 1-1/4 in. DN32 10 gpm 2.27 m3/h 6.5 ft 3.0 psid 21 kPa 109 ft 50 psid 340 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit
VRN2DM3DFX 1-1/4 in. DN32 10 gpm 2.27 m3/h 6.5 ft 3.0 psid 21 kPa 109 ft 50 psid 340 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque
VRN2DM3S2A 1-1/4 in. DN32 10 gpm 2.27 m3/h 6.5 ft 3.0 psid 21 kPa 109 ft 50 psid 340 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2DM3SFX 1-1/4 in. DN32 10 gpm 2.27 m3/h 6.5 ft 3.0 psid 21 kPa 109 ft 50 psid 340 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 35 lb-in torque
VRN2DN3D2A 1-1/4 in. DN32 15 gpm 3.41 m3/h 6.5 ft 3.0 psid 21 kPa 109 ft 50 psid 340 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit
VRN2DN3DFX 1-1/4 in. DN32 15 gpm 3.41 m3/h 6.5 ft 3.0 psid 21 kPa 109 ft 50 psid 340 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque
VRN2DN3S2A 1-1/4 in. DN32 15 gpm 3.41 m3/h 6.5 ft 3.0 psid 21 kPa 109 ft 50 psid 340 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2DN3SFX 1-1/4 in. DN32 15 gpm 3.41 m3/h 6.5 ft 3.0 psid 21 kPa 109 ft 50 psid 340 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 35 lb-in torque
VRN2DP3D2A 1-1/4 in. DN32 20 gpm 4.54 m3/h 8.7 ft 4.0 psid 28 kPa 109 ft 50 psid 340 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit
VRN2DP3DFX 1-1/4 in. DN32 20 gpm 4.54 m3/h 8.7 ft 4.0 psid 28 kPa 109 ft 50 psid 340 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque
VRN2DP3S2A 1-1/4 in. DN32 20 gpm 4.54 m3/h 8.7 ft 4.0 psid 28 kPa 109 ft 50 psid 340 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2DP3SFX 1-1/4 in. DN32 20 gpm 4.54 m3/h 8.7 ft 4.0 psid 28 kPa 109 ft 50 psid 340 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 35 lb-in torque
VRN2DQ3D2A 1-1/4 in. DN32 25 gpm 5.68 m3/h 10.9 ft 5.0 psid 34 kPa 109 ft 50 psid 340 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit
VRN2DQ3DFX 1-1/4 in. DN32 25 gpm 5.68 m3/h 10.9 ft 5.0 psid 34 kPa 109 ft 50 psid 340 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque
VRN2DQ3S2A 1-1/4 in. DN32 25 gpm 5.68 m3/h 10.9 ft 5.0 psid 34 kPa 109 ft 50 psid 340 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2DQ3SFX 1-1/4 in. DN32 25 gpm 5.68 m3/h 10.9 ft 5.0 psid 34 kPa 109 ft 50 psid 340 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 35 lb-in torque
VRN2DR3D2A 1-1/4 in. DN32 30 gpm 6.81 m3/h 10.9 ft 5.0 psid 34 kPa 109 ft 50 psid 340 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit
VRN2DR3DFX 1-1/4 in. DN32 30 gpm 6.81 m3/h 10.9 ft 5.0 psid 34 kPa 109 ft 50 psid 340 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque
VRN2DR3S2A 1-1/4 in. DN32 30 gpm 6.81 m3/h 10.9 ft 5.0 psid 34 kPa 109 ft 50 psid 340 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2DR3SFX 1-1/4 in. DN32 30 gpm 6.81 m3/h 10.9 ft 5.0 psid 34 kPa 109 ft 50 psid 340 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 35 lb-in torque
VRN2EU3D2A 1-1/2 in. DN40 45 gpm 10 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit
VRN2EU3DFX 1-1/2 in. DN40 45 gpm 10 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque
VRN2EU3S2A 1-1/2 in. DN40 45 gpm 10 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2EU3SFX 1-1/2 in. DN40 45 gpm 10 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 35 lb-in torque
VRN2E13D2A 1-1/2 in. DN40 50 gpm 11 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit
VRN2E13DFX 1-1/2 in. DN40 50 gpm 11 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque
VRN2E13S2A 1-1/2 in. DN40 50 gpm 11 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2E13SFX 1-1/2 in. DN40 50 gpm 11 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 35 lb-in torque
VRN2EM3D2A 1-1/2 in. DN40 10 gpm 2.27 m3/h 6.5 ft 3.0 psid 21 kPa 109 ft 50 psid 340 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit

556 customer.honeywell.com 70-6910


Pressure-regulated Control Valves

Controls
Valve Size Maximum Flow Minimum head loss Maximum head loss Materials

Home
(Plug/
Ball/ Available
Product Number (inch) (DN) (gpm) (m3/h) (ft) (psi) (kPa) (ft) (psi) (kPa) Disc) (Stem) Includes Accessories
VRN2EM3DFX 1-1/2 in. DN40 10 gpm 2.27 m3/h 6.5 ft 3.0 psid 21 kPa 109 ft 50 psid 340 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque
VRN2EM3S2A 1-1/2 in. DN40 10 gpm 2.27 m3/h 6.5 ft 3.0 psid 21 kPa 109 ft 50 psid 340 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary

Indoor Air Quality


Steel Steel switch kit
VRN2EM3SFX 1-1/2 in. DN40 10 gpm 2.27 m3/h 6.5 ft 3.0 psid 21 kPa 109 ft 50 psid 340 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 35 lb-in torque
VRN2EN3D2A 1-1/2 in. DN40 15 gpm 3.41 m3/h 6.5 ft 3.0 psid 21 kPa 109 ft 50 psid 340 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit
VRN2EN3DFX 1-1/2 in. DN40 15 gpm 3.41 m3/h 6.5 ft 3.0 psid 21 kPa 109 ft 50 psid 340 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque
VRN2EN3S2A 1-1/2 in. DN40 15 gpm 3.41 m3/h 6.5 ft 3.0 psid 21 kPa 109 ft 50 psid 340 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary

Combustion Controls
Steel Steel switch kit
VRN2EN3SFX 1-1/2 in. DN40 15 gpm 3.41 m3/h 6.5 ft 3.0 psid 21 kPa 109 ft 50 psid 340 kPa Stainless Stainless Two shafts, universal DCA, minimum

Residential
Steel Steel anti-rotation bar 35 lb-in torque
VRN2EP3D2A 1-1/2 in. DN40 20 gpm 4.54 m3/h 8.7 ft 4.0 psid 28 kPa 109 ft 50 psid 340 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit
VRN2EP3DFX 1-1/2 in. DN40 20 gpm 4.54 m3/h 8.7 ft 4.0 psid 28 kPa 109 ft 50 psid 340 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque
VRN2EP3S2A 1-1/2 in. DN40 20 gpm 4.54 m3/h 8.7 ft 4.0 psid 28 kPa 109 ft 50 psid 340 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit

Hydronic Controls
VRN2EP3SFX 1-1/2 in. DN40 20 gpm 4.54 m3/h 8.7 ft 4.0 psid 28 kPa 109 ft 50 psid 340 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 35 lb-in torque
VRN2EQ3D2A 1-1/2 in. DN40 25 gpm 5.68 m3/h 10.9 ft 5.0 psid 34 kPa 109 ft 50 psid 340 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit
VRN2EQ3DFX 1-1/2 in. DN40 25 gpm 5.68 m3/h 10.9 ft 5.0 psid 34 kPa 109 ft 50 psid 340 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque
VRN2EQ3S2A 1-1/2 in. DN40 25 gpm 5.68 m3/h 10.9 ft 5.0 psid 34 kPa 109 ft 50 psid 340 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2EQ3SFX 1-1/2 in. DN40 25 gpm 5.68 m3/h 10.9 ft 5.0 psid 34 kPa 109 ft 50 psid 340 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 35 lb-in torque

Controls
VRN2ER3D2A 1-1/2 in. DN40 30 gpm 6.81 m3/h 10.9 ft 5.0 psid 34 kPa 109 ft 50 psid 340 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary

Water
brass switch kit
VRN2ER3DFX 1-1/2 in. DN40 30 gpm 6.81 m3/h 10.9 ft 5.0 psid 34 kPa 109 ft 50 psid 340 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque
VRN2ER3S2A 1-1/2 in. DN40 30 gpm 6.81 m3/h 10.9 ft 5.0 psid 34 kPa 109 ft 50 psid 340 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2ER3SFX 1-1/2 in. DN40 30 gpm 6.81 m3/h 10.9 ft 5.0 psid 34 kPa 109 ft 50 psid 340 kPa Stainless Stainless Two shafts, universal DCA, minimum

Building Automation
Steel Steel anti-rotation bar 35 lb-in torque
VRN2ES3D2A 1-1/2 in. DN40 35 gpm 7.95 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit
VRN2ES3DFX 1-1/2 in. DN40 35 gpm 7.95 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque
VRN2ES3S2A 1-1/2 in. DN40 35 gpm 7.95 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2ES3SFX 1-1/2 in. DN40 35 gpm 7.95 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 35 lb-in torque

Components
VRN2ET3D2A 1-1/2 in. DN40 40 gpm 9.08 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary

Commercial
brass switch kit
VRN2ET3DFX 1-1/2 in. DN40 40 gpm 9.08 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque
VRN2ET3S2A 1-1/2 in. DN40 40 gpm 9.08 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2ET3SFX 1-1/2 in. DN40 40 gpm 9.08 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 35 lb-in torque
Pneumatic Controls

VRN2FU3D2A 2 in. DN50 45 gpm 10 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit
VRN2FU3DFX 2 in. DN50 45 gpm 10 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque
VRN2FU3S2A 2 in. DN50 45 gpm 10 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2FU3SFX 2 in. DN50 45 gpm 10 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 35 lb-in torque
Industrial Combustion

VRN2F13D2A 2 in. DN50 50 gpm 11 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit
Controls

VRN2F13DFX 2 in. DN50 50 gpm 11 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque

70-6910 557
Pressure-regulated Control Valves
Valve Size Maximum Flow Minimum head loss Maximum head loss Materials
(Plug/
Ball/ Available
Product Number (inch) (DN) (gpm) (m3/h) (ft) (psi) (kPa) (ft) (psi) (kPa) Disc) (Stem) Includes Accessories
VRN2F13S2A 2 in. DN50 50 gpm 11 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2F13SFX 2 in. DN50 50 gpm 11 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 35 lb-in torque
VRN2F23D2A 2 in. DN50 55 gpm 12 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit
VRN2F23DFX 2 in. DN50 55 gpm 12 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque
VRN2F23S2A 2 in. DN50 55 gpm 12 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2F23SFX 2 in. DN50 55 gpm 12 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 35 lb-in torque
VRN2F33D2A 2 in. DN50 60 gpm 14 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit
VRN2F33DFX 2 in. DN50 60 gpm 14 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque
VRN2F33S2A 2 in. DN50 60 gpm 14 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2F33SFX 2 in. DN50 60 gpm 14 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 35 lb-in torque
VRN2F43D2A 2 in. DN50 65 gpm 15 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit
VRN2F43DFX 2 in. DN50 65 gpm 15 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque
VRN2F43S2A 2 in. DN50 65 gpm 15 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2F43SFX 2 in. DN50 65 gpm 15 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 35 lb-in torque
VRN2F53D2A 2 in. DN50 70 gpm 16 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit
VRN2F53DFX 2 in. DN50 70 gpm 16 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque
VRN2F53S2A 2 in. DN50 70 gpm 16 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2F53SFX 2 in. DN50 70 gpm 16 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 35 lb-in torque
VRN2F63D2A 2 in. DN50 75 gpm 17 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit
VRN2F63DFX 2 in. DN50 75 gpm 17 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque
VRN2F63S2A 2 in. DN50 75 gpm 17 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2F63SFX 2 in. DN50 75 gpm 17 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 35 lb-in torque
VRN2FQ3D2A 2 in. DN50 25 gpm 5.68 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit
VRN2FQ3DFX 2 in. DN50 25 gpm 5.68 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque
VRN2FQ3S2A 2 in. DN50 25 gpm 5.68 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2FQ3SFX 2 in. DN50 25 gpm 5.68 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 35 lb-in torque
VRN2FR3D2A 2 in. DN50 30 gpm 6.81 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit
VRN2FR3DFX 2 in. DN50 30 gpm 6.81 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque
VRN2FR3S2A 2 in. DN50 30 gpm 6.81 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2FR3SFX 2 in. DN50 30 gpm 6.81 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 35 lb-in torque
VRN2FS3D2A 2 in. DN50 35 gpm 7.95 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit
VRN2FS3DFX 2 in. DN50 35 gpm 7.95 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque
VRN2FS3S2A 2 in. DN50 35 gpm 7.95 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit

558 customer.honeywell.com 70-6910


Pressure-regulated Control Valves

Controls
Valve Size Maximum Flow Minimum head loss Maximum head loss Materials

Home
(Plug/
Ball/ Available
Product Number (inch) (DN) (gpm) (m3/h) (ft) (psi) (kPa) (ft) (psi) (kPa) Disc) (Stem) Includes Accessories
VRN2FS3SFX 2 in. DN50 35 gpm 7.95 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 35 lb-in torque
VRN2FT3D2A 2 in. DN50 40 gpm 9.08 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary

Indoor Air Quality


brass switch kit
VRN2FT3DFX 2 in. DN50 40 gpm 9.08 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque
VRN2FT3S2A 2 in. DN50 40 gpm 9.08 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2FT3SFX 2 in. DN50 40 gpm 9.08 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 35 lb-in torque
VRN2GU3D2A 2-1/2 in. DN65 45 gpm 10 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary

Combustion Controls
brass switch kit
VRN2GU3DFX 2-1/2 in. DN65 45 gpm 10 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Plated Brass Two shafts, universal DCA, minimum

Residential
brass anti-rotation bar 35 lb-in torque
VRN2GU3S2A 2-1/2 in. DN65 45 gpm 10 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2GU3SFX 2-1/2 in. DN65 45 gpm 10 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 35 lb-in torque
VRN2G13D2A 2-1/2 in. DN65 50 gpm 11 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit

Hydronic Controls
VRN2G13DFX 2-1/2 in. DN65 50 gpm 11 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque
VRN2G13S2A 2-1/2 in. DN65 50 gpm 11 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2G13SFX 2-1/2 in. DN65 50 gpm 11 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 35 lb-in torque
VRN2G23D2A 2-1/2 in. DN65 55 gpm 12 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit
VRN2G23DFX 2-1/2 in. DN65 55 gpm 12 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque

Controls
VRN2G23S2A 2-1/2 in. DN65 55 gpm 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary

Water
12 m3/h
Steel Steel switch kit
VRN2G23SFX 2-1/2 in. DN65 55 gpm 12 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 35 lb-in torque
VRN2G33D2A 2-1/2 in. DN65 60 gpm 14 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit
VRN2G33DFX 2-1/2 in. DN65 60 gpm 14 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Plated Brass Two shafts, universal DCA, minimum

Building Automation
brass anti-rotation bar 35 lb-in torque
VRN2G33S2A 2-1/2 in. DN65 60 gpm 14 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2G33SFX 2-1/2 in. DN65 60 gpm 14 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 35 lb-in torque
VRN2G43D2A 2-1/2 in. DN65 65 gpm 15 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit
VRN2G43DFX 2-1/2 in. DN65 65 gpm 15 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque

Components
VRN2G43S2A 2-1/2 in. DN65 65 gpm 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary

Commercial
15 m3/h
Steel Steel switch kit
VRN2G43SFX 2-1/2 in. DN65 65 gpm 15 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 35 lb-in torque
VRN2G53D2A 2-1/2 in. DN65 70 gpm 16 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit
VRN2G53DFX 2-1/2 in. DN65 70 gpm 16 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque
Pneumatic Controls

VRN2G53S2A 2-1/2 in. DN65 70 gpm 16 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2G53SFX 2-1/2 in. DN65 70 gpm 16 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 35 lb-in torque
VRN2G63D2A 2-1/2 in. DN65 75 gpm 17 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit
VRN2G63DFX 2-1/2 in. DN65 75 gpm 17 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque
Industrial Combustion

VRN2G63S2A 2-1/2 in. DN65 75 gpm 17 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit
Controls

VRN2G63SFX 2-1/2 in. DN65 75 gpm 17 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 35 lb-in torque

70-6910 559
Pressure-regulated Control Valves
Valve Size Maximum Flow Minimum head loss Maximum head loss Materials
(Plug/
Ball/ Available
Product Number (inch) (DN) (gpm) (m3/h) (ft) (psi) (kPa) (ft) (psi) (kPa) Disc) (Stem) Includes Accessories
VRN2G73D2A 2-1/2 in. DN65 80 gpm 18 m3/h 21.8 ft 10.0 psid 69 kPa 126 ft 58 psid 400 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit
VRN2G73DFX 2-1/2 in. DN65 80 gpm 18 m3/h 21.8 ft 10.0 psid 69 kPa 126 ft 58 psid 400 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque
VRN2G73S2A 2-1/2 in. DN65 80 gpm 18 m3/h 21.8 ft 10.0 psid 69 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2G73SFX 2-1/2 in. DN65 80 gpm 18 m3/h 21.8 ft 10.0 psid 69 kPa 126 ft 58 psid 400 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 35 lb-in torque
VRN2G83D2A 2-1/2 in. DN65 85 gpm 19 m3/h 21.8 ft 10.0 psid 69 kPa 126 ft 58 psid 400 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit
VRN2G83DFX 2-1/2 in. DN65 85 gpm 19 m3/h 21.8 ft 10.0 psid 69 kPa 126 ft 58 psid 400 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque
VRN2G83S2A 2-1/2 in. DN65 85 gpm 19 m3/h 21.8 ft 10.0 psid 69 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2G83SFX 2-1/2 in. DN65 85 gpm 19 m3/h 21.8 ft 10.0 psid 69 kPa 126 ft 58 psid 400 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 35 lb-in torque
VRN2GQ3D2A 2-1/2 in. DN65 25 gpm 5.68 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit
VRN2GQ3DFX 2-1/2 in. DN65 25 gpm 5.68 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque
VRN2GQ3S2A 2-1/2 in. DN65 25 gpm 5.68 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2GQ3SFX 2-1/2 in. DN65 25 gpm 5.68 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 35 lb-in torque
VRN2GR3D2A 2-1/2 in. DN65 30 gpm 6.81 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit
VRN2GR3DFX 2-1/2 in. DN65 30 gpm 6.81 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque
VRN2GR3S2A 2-1/2 in. DN65 30 gpm 6.81 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2GR3SFX 2-1/2 in. DN65 30 gpm 6.81 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 35 lb-in torque
VRN2GS3D2A 2-1/2 in. DN65 35 gpm 7.95 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit
VRN2GS3DFX 2-1/2 in. DN65 35 gpm 7.95 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque
VRN2GS3S2A 2-1/2 in. DN65 35 gpm 7.95 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2GS3SFX 2-1/2 in. DN65 35 gpm 7.95 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 35 lb-in torque
VRN2GT3D2A 2-1/2 in. DN65 40 gpm 9.08 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit
VRN2GT3DFX 2-1/2 in. DN65 40 gpm 9.08 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque
VRN2GT3S2A 2-1/2 in. DN65 40 gpm 9.08 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2GT3SFX 2-1/2 in. DN65 40 gpm 9.08 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 35 lb-in torque
VRN2HQ3D2A 3 in. DN80 25 gpm 5.68 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit
VRN2HQ3DFX 3 in. DN80 25 gpm 5.68 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque
VRN2HQ3S2A 3 in. DN80 25 gpm 5.68 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2HQ3SFX 3 in. DN80 25 gpm 5.68 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 35 lb-in torque
VRN2HR3D2A 3 in. DN80 30 gpm 6.81 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit
VRN2HR3DFX 3 in. DN80 30 gpm 6.81 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque
VRN2HR3S2A 3 in. DN80 30 gpm 6.81 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2HR3SFX 3 in. DN80 30 gpm 6.81 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 35 lb-in torque
VRN2HS3D2A 3 in. DN80 35 gpm 7.95 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit

560 customer.honeywell.com 70-6910


Pressure-regulated Control Valves

Controls
Valve Size Maximum Flow Minimum head loss Maximum head loss Materials

Home
(Plug/
Ball/ Available
Product Number (inch) (DN) (gpm) (m3/h) (ft) (psi) (kPa) (ft) (psi) (kPa) Disc) (Stem) Includes Accessories
VRN2HS3DFX 3 in. DN80 35 gpm 7.95 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque
VRN2HS3S2A 3 in. DN80 35 gpm 7.95 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary

Indoor Air Quality


Steel Steel switch kit
VRN2HS3SFX 3 in. DN80 35 gpm 7.95 m3/h 8.7 ft 4.0 psid 28 kPa 126 ft 58 psid 400 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 35 lb-in torque
VRN2HT3D2A 3 in. DN80 40 gpm 9.08 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit
VRN2HT3DFX 3 in. DN80 40 gpm 9.08 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque
VRN2HT3S2A 3 in. DN80 40 gpm 9.08 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary

Combustion Controls
Steel Steel switch kit
VRN2HT3SFX 3 in. DN80 40 gpm 9.08 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Stainless Stainless Two shafts, universal DCA, minimum

Residential
Steel Steel anti-rotation bar 35 lb-in torque
VRN2HU3D2A 3 in. DN80 45 gpm 10 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit
VRN2HU3DFX 3 in. DN80 45 gpm 10 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque
VRN2HU3S2A 3 in. DN80 45 gpm 10 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit

Hydronic Controls
VRN2HU3SFX 3 in. DN80 45 gpm 10 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 35 lb-in torque
VRN2H13D2A 3 in. DN80 50 gpm 11 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit
VRN2H13DFX 3 in. DN80 50 gpm 11 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque
VRN2H13S2A 3 in. DN80 50 gpm 11 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2H13SFX 3 in. DN80 50 gpm 11 m3/h 13.1 ft 6.0 psid 41 kPa 126 ft 58 psid 400 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 35 lb-in torque

Controls
VRN2H23D2A 3 in. DN80 55 gpm 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary

Water
12 m3/h
brass switch kit
VRN2H23DFX 3 in. DN80 55 gpm 12 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque
VRN2H23S2A 3 in. DN80 55 gpm 12 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2H23SFX 3 in. DN80 55 gpm 12 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Stainless Stainless Two shafts, universal DCA, minimum

Building Automation
Steel Steel anti-rotation bar 35 lb-in torque
VRN2H33D2A 3 in. DN80 60 gpm 14 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit
VRN2H33DFX 3 in. DN80 60 gpm 14 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque
VRN2H33S2A 3 in. DN80 60 gpm 14 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2H33SFX 3 in. DN80 60 gpm 14 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 35 lb-in torque

Components
VRN2H43D2A 3 in. DN80 65 gpm 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary

Commercial
15 m3/h
brass switch kit
VRN2H43DFX 3 in. DN80 65 gpm 15 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque
VRN2H43S2A 3 in. DN80 65 gpm 15 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2H43SFX 3 in. DN80 65 gpm 15 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 35 lb-in torque
Pneumatic Controls

VRN2H53D2A 3 in. DN80 70 gpm 16 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit
VRN2H53DFX 3 in. DN80 70 gpm 16 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque
VRN2H53S2A 3 in. DN80 70 gpm 16 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2H53SFX 3 in. DN80 70 gpm 16 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 35 lb-in torque
Industrial Combustion

VRN2H63D2A 3 in. DN80 75 gpm 17 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit
Controls

VRN2H63DFX 3 in. DN80 75 gpm 17 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque

70-6910 561
Pressure-regulated Control Valves
Valve Size Maximum Flow Minimum head loss Maximum head loss Materials
(Plug/
Ball/ Available
Product Number (inch) (DN) (gpm) (m3/h) (ft) (psi) (kPa) (ft) (psi) (kPa) Disc) (Stem) Includes Accessories
VRN2H63S2A 3 in. DN80 75 gpm 17 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2H63SFX 3 in. DN80 75 gpm 17 m3/h 15.2 ft 7.0 psid 48 kPa 126 ft 58 psid 400 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 35 lb-in torque
VRN2H73D2A 3 in. DN80 80 gpm 18 m3/h 21.8 ft 10.0 psid 69 kPa 126 ft 58 psid 400 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit
VRN2H73DFX 3 in. DN80 80 gpm 18 m3/h 21.8 ft 10.0 psid 69 kPa 126 ft 58 psid 400 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque
VRN2H73S2A 3 in. DN80 80 gpm 18 m3/h 21.8 ft 10.0 psid 69 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2H73SFX 3 in. DN80 80 gpm 18 m3/h 21.8 ft 10.0 psid 69 kPa 126 ft 58 psid 400 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 35 lb-in torque
VRN2H83D2A 3 in. DN80 85 gpm 19 m3/h 21.8 ft 10.0 psid 69 kPa 126 ft 58 psid 400 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit
VRN2H83DFX 3 in. DN80 85 gpm 19 m3/h 21.8 ft 10.0 psid 69 kPa 126 ft 58 psid 400 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque
VRN2H83S2A 3 in. DN80 85 gpm 19 m3/h 21.8 ft 10.0 psid 69 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2H83SFX 3 in. DN80 85 gpm 19 m3/h 21.8 ft 10.0 psid 69 kPa 126 ft 58 psid 400 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 35 lb-in torque

Flow Characteristics: Full port ball


Comments: Full port ball; 2 - 10V position feedback signal

Valve Size Maximum Flow Minimum head loss Maximum head loss Materials
(Plug/
Ball/ Available
3/
Product Number (inch) (DN) (gpm) (m h) (ft) (psi) (kPa) (ft) (psi) (kPa) Disc) (Stem) Includes Accessories
VRN2BM3D2B 3/4 in. DN20 10 gpm 2.27 m3/h 13.1 ft 6.0 psid 41 kPa 76 ft 35 psid 240 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
VRN2BM3D2D 3/4 in. DN20 10 gpm 2.27 m3/h 13.1 ft 6.0 psid 41 kPa 76 ft 35 psid 240 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA
VRN2BM3S2B 3/4 in. DN20 10 gpm 2.27 m3/h 13.1 ft 6.0 psid 41 kPa 76 ft 35 psid 240 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2BM3S2D 3/4 in. DN20 10 gpm 2.27 m3/h 13.1 ft 6.0 psid 41 kPa 76 ft 35 psid 240 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
VRN2DS3D2B 1-1/4 in. DN32 35 gpm 7.95 m3/h 14.1 ft 6.5 psid 45 kPa 126 ft 58 psid 400 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
VRN2DS3D2D 1-1/4 in. DN32 35 gpm 7.95 m3/h 14.1 ft 6.5 psid 45 kPa 126 ft 58 psid 400 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA
VRN2DS3S2D 1-1/4 in. DN32 35 gpm 7.95 m3/h 14.1 ft 6.5 psid 45 kPa 126 ft 58 psid 400 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
VRN2G93D2B 2-1/2 in. DN65 95 gpm 22 m3/h 26.1 ft 12.0 psid 83 kPa 126 ft 58 psid 400 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
VRN2G93D2D 2-1/2 in. DN65 95 gpm 22 m3/h 26.1 ft 12.0 psid 83 kPa 126 ft 58 psid 400 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA
VRN2G93S2B 2-1/2 in. DN65 95 gpm 22 m3/h 26.1 ft 12.0 psid 83 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2G93S2D 2-1/2 in. DN65 95 gpm 22 m3/h 26.1 ft 12.0 psid 83 kPa 126 ft 58 psid 400 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA
VRN2H93D2B 3 in. DN80 95 gpm 22 m3/h 26.1 ft 12.0 psid 83 kPa 126 ft 58 psid 400 kPa Plated Brass MN7505 Modulating DCA SSW2 Auxiliary
brass switch kit
VRN2H93D2D 3 in. DN80 95 gpm 22 m3/h 26.1 ft 12.0 psid 83 kPa 126 ft 58 psid 400 kPa Plated Brass MS7505 "Zelix" Modulating
brass Spring Return DCA
VRN2H93S2B 3 in. DN80 95 gpm 22 m3/h 26.1 ft 12.0 psid 83 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN7505 Modulating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2H93S2D 3 in. DN80 95 gpm 22 m3/h 26.1 ft 12.0 psid 83 kPa 126 ft 58 psid 400 kPa Stainless Stainless MS7505 "Zelix" Modulating
Steel Steel Spring Return DCA

562 customer.honeywell.com 70-6910


Pressure-regulated Control Valves
Comments: Full port ball; No feedback

Controls
Home
Valve Size Maximum Flow Minimum head loss Maximum head loss Materials
(Plug/
Ball/ Available
Product Number (inch) (DN) (gpm) (m3/h) (ft) (psi) (kPa) (ft) (psi) (kPa) Disc) (Stem) Includes Accessories
VRN2BM3D2A 3/4 in. DN20 10 gpm 2.27 m3/h 13.1 ft 6.0 psid 41 kPa 76 ft 35 psid 240 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit

Indoor Air Quality


VRN2BM3DFX 3/4 in. DN20 10 gpm 2.27 m3/h 13.1 ft 6.0 psid 41 kPa 76 ft 35 psid 240 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 27 lb-in torque
VRN2BM3S2A 3/4 in. DN20 10 gpm 2.27 m3/h 13.1 ft 6.0 psid 41 kPa 76 ft 35 psid 240 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2BM3SFX 3/4 in. DN20 10 gpm 2.27 m3/h 13.1 ft 6.0 psid 41 kPa 76 ft 35 psid 240 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 27 lb-in torque
VRN2DS3D2A 1-1/4 in. DN32 35 gpm 7.95 m3/h 14.1 ft 6.5 psid 45 kPa 126 ft 58 psid 400 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit

Combustion Controls
VRN2DS3DFX 1-1/4 in. DN32 35 gpm 7.95 m3/h 14.1 ft 6.5 psid 45 kPa 126 ft 58 psid 400 kPa Plated Brass Two shafts, universal DCA, minimum

Residential
brass anti-rotation bar 35 lb-in torque
VRN2DS3S2A 1-1/4 in. DN32 35 gpm 7.95 m3/h 14.1 ft 6.5 psid 45 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2DS3SFX 1-1/4 in. DN32 35 gpm 7.95 m3/h 14.1 ft 6.5 psid 45 kPa 126 ft 58 psid 400 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 35 lb-in torque
VRN2G93D2A 2-1/2 in. DN65 95 gpm 22 m3/h 26.1 ft 12.0 psid 83 kPa 126 ft 58 psid 400 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit

Hydronic Controls
VRN2G93DFX 2-1/2 in. DN65 95 gpm 22 m3/h 26.1 ft 12.0 psid 83 kPa 126 ft 58 psid 400 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque
VRN2G93S2A 2-1/2 in. DN65 95 gpm 22 m3/h 26.1 ft 12.0 psid 83 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary
Steel Steel switch kit
VRN2G93SFX 2-1/2 in. DN65 95 gpm 22 m3/h 26.1 ft 12.0 psid 83 kPa 126 ft 58 psid 400 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 35 lb-in torque
VRN2H93D2A 3 in. DN80 95 gpm 22 m3/h 26.1 ft 12.0 psid 83 kPa 126 ft 58 psid 400 kPa Plated Brass MN6105 Floating DCA SSW2 Auxiliary
brass switch kit
VRN2H93DFX 3 in. DN80 95 gpm 22 m3/h 26.1 ft 12.0 psid 83 kPa 126 ft 58 psid 400 kPa Plated Brass Two shafts, universal DCA, minimum
brass anti-rotation bar 35 lb-in torque

Controls
VRN2H93S2A 3 in. DN80 95 gpm 22 m3/h 26.1 ft 12.0 psid 83 kPa 126 ft 58 psid 400 kPa Stainless Stainless MN6105 Floating DCA SSW2 Auxiliary

Water
Steel Steel switch kit
VRN2H93SFX 3 in. DN80 95 gpm 22 m3/h 26.1 ft 12.0 psid 83 kPa 126 ft 58 psid 400 kPa Stainless Stainless Two shafts, universal DCA, minimum
Steel Steel anti-rotation bar 35 lb-in torque

Building Automation
Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 563
Pressure-regulated Control Valves
Wafer Flanged Dynamic Pressure-regulated Control Valves
Pressure independent control valves are sized to match design
coil flow regardless of coil size. VRW2 valves eliminate the need to
balance the system for proper flow, and allow chillers to be
operated at design temperature differential for maximum efficiency
at every load condition. When used in a system with variable
speed pump drives, 3-way valves and coil bypass lines are not
required.
Systems that utilize the capabilities of properly installed, adjusted,
and monitored pressure-independent control valves may qualify
for LEED points.
• Multi-sized bodies from 21/2 to 6 inch pipes with wafer flanged
connections.
• Combination ANSI/ASME Class 150/300 pressure rating.
• Controls hot or chilled water with up to 50% glycol.
• Regulated flow rates available from 39 to 469 gpm.
• Stainless steel pressure regulator maintains constant pressure drop
across valve seat.
• Positive pressure, rolling diaphragm regulator design provides flow
The VRW2 two-way dynamic pressure-regulating control valves control accuracy of ±5% over specified pressure range.
maintain constant flow of hot and chilled water in closed-loop • Equal percentage flow characteristic using multi turn, non-rising,
heating, ventilating, and air conditioning (HVAC) systems characterized plug.
regardless of head pressure fluctuations above minimum specified • High close-off rating.
pressure drop. These valves come complete with proportional, • 50 discrete, selectable flow rates available per valve size.
stay-in-place or electronic fail-safe actuators. • Stainless steel trim.
The built-in differential pressure regulator makes fluid flow • Six-turn actuator with floating or modulating inputs available with
through the valve independent of changes in supply pressure, stay-in-place or electronic fail-safe action.
eliminating "hunting" by the control system, even at low coil flow. • Fail-safe actuators field-configurable for normally open or normally
The pressure regulator virtually eliminates cavitation in the valve, closed power failure return position.
and decouples the control valve from the effects of piping • Two Test Ports for venting or pressure gauge attachment.
components such as reducers and elbows.

Dimensions in inches (millimeters)


Valve Type: Wafer flanged dynamic pressure-regulated control valve
Body Pattern: 2-way, straight-through
Flow Characteristic: Equal Percentage
Pipe Connection Type: Wafer flange
Controlled Fluid: Chilled or hot water with up to 50% Glycol. Not for
use with steam or fuels.
Valve Action: Multi-turn linear
Leakage Rating: 0.2% max.
H1 Maximum Safe Operating Pressure: 580 psig (4000 kPa)
Maximum Safe Operating Temperature: 248 F (120 C)
Maximum Close-off Pressure: 101 psid (700 kPa)
Fluid Temperature Range: -4 F to 248 F (-20 C to 120 C)
Ambient Temperature Range: 14 F to 131 F (-10 C to 55 C)
Accuracy: ±5% over specified pressure range
Stem Travel: 1 to 6 Rotations in 51 equal, field-selectable increments
ANSI/ ASME Class: 150/300
H2
Comments: 2 - 10V position feedback signal
Materials
(Body): Ductile Iron, ASTM A536ñ65T, Class 60-45-18
(Stem): Stainless Steel
(Seat): 316 Stainless steel
L (Regulator): 316 Stainless steel
(Plug/Ball/Disc): 316 stainless steel
(Packing): EPDM and Nitrile O-rings
L H1 H2 (Diaphragm): EPDM
in. mm in. mm in. mm
8 3/4 224 9 3/4 246 3 3/4 95
12 5/8 320 11 3/8 290 5 1/4 135
16 5/8 422 13 1/4 338 7 1/8 180

M31311

Valve Size Maximum Flow Minimum head loss Maximum head loss
Product Number (inch) (DN) (gpm) (m3/h) (ft) (psi) (kPa) (ft) (psi) (kPa) Includes
VRW2JV4SMB 2-1/2 in.; 3 in. DN65; DN80 112 gpm 25 m3/h 11.1 ft 5.1 psid 35 kPa 126 ft 58 psid 400 kPa Modulating/Floating
actuator
VRW2JV4SMD 2-1/2 in.; 3 in. DN65; DN80 112 gpm 25 m3/h 11.1 ft 5.1 psid 35 kPa 126 ft 58 psid 400 kPa Modulating/Floating
Fail-safe actuator
VRW2JW4SMB 2-1/2 in.; 3 in. DN65; DN80 155 gpm 35 m3/h 25.3 ft 11.6 psid 80 kPa 126 ft 58 psid 400 kPa Modulating/Floating
actuator

564 customer.honeywell.com 70-6910


Pressure-regulated Control Valves

Controls
Valve Size Maximum Flow Minimum head loss Maximum head loss

Home
Product Number (inch) (DN) (gpm) (m3/h) (ft) (psi) (kPa) (ft) (psi) (kPa) Includes
VRW2JW4SMD 2-1/2 in.; 3 in. DN65; DN80 155 gpm 35 m3/h 25.3 ft 11.6 psid 80 kPa 126 ft 58 psid 400 kPa Modulating/Floating
Fail-safe actuator
VRW2KV4SMB 3in.; 4 in. DN80; DN100 147 gpm 33 m3/h 11.1 ft 5.1 psid 35 kPa 126 ft 58 psid 400 kPa Modulating/Floating
actuator

Indoor Air Quality


VRW2KV4SMD 3in.; 4 in. DN80; DN100 147 gpm 33 m3/h 11.1 ft 5.1 psid 35 kPa 126 ft 58 psid 400 kPa Modulating/Floating
Fail-safe actuator
VRW2KW4SMB 3in.; 4 in. DN80; DN100 222 gpm 50 m3/h 18.7 ft 8.6 psid 59 kPa 126 ft 58 psid 400 kPa Modulating/Floating
actuator
VRW2KW4SMD 3in.; 4 in. DN80; DN100 222 gpm 50 m3/h 18.7 ft 8.6 psid 59 kPa 126 ft 58 psid 400 kPa Modulating/Floating
Fail-safe actuator
VRW2LV4SMB 5 in.; 6 in. DN125; DN150 370 gpm 84 m3/h 11.1 ft 5.1 psid 35 kPa 126 ft 58 psid 400 kPa Modulating/Floating
actuator

Combustion Controls
VRW2LV4SMD 5 in.; 6 in. DN125; DN150 370 gpm 84 m3/h 11.1 ft 5.1 psid 35 kPa 126 ft 58 psid 400 kPa Modulating/Floating
Fail-safe actuator

Residential
VRW2LW4SMB 5 in.; 6 in. DN125; DN150 469 gpm 106 m3/h 18.7 ft 8.6 psid 59 kPa 126 ft 58 psid 400 kPa Modulating/Floating
actuator
VRW2LW4SMD 5 in.; 6 in. DN125; DN150 469 gpm 106 m3/h 18.7 ft 8.6 psid 59 kPa 126 ft 58 psid 400 kPa Modulating/Floating
Fail-safe actuator

Hydronic Controls
Controls
Water
Building Automation
Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 565
Control Ball Valves
VBF2; VBF3; VBN2; VBN3 Control Ball Valves
Valve Fitting Body/Flow Size CV T/P Trim Enclosure Actuator
VB = valve, ball
F = Flanged
N = Female NPT threaded
2 = 2 way
3 = 3 way
inch S.I. metric
A 1/2 DN15
B 3/4 DN20
C 1 DN25
D 1-1/4 DN32
E 1-1/2 DN40
F 2 DN50
G 2-1/2 DN65
H 3 DN80
J 4 DN100
K 5 DN125
L 6 DN150
B CV Designator (specific values vary by valve size)
C
D
E
F
….
S
T
U
1
2
3
4
5
6
7
1 = ANSI Valve construction
3 = ANSI 300 Valve construction
P = Plated (chrome or nickel)
S = Stainless Steel
0 = no enclosure
R = NEMA 3R enclosure
X = no actuator
A = NSR, Floating, conduit
B = NSR, Modulating
C = SR, 2-Position, 24 Vac
D = SR, Floating/Modulating
F = NSR, Floating, open terminal
strip, 1/2 and 3/4 inch only

VB F 2 A B 1 S 0 A

566 customer.honeywell.com 70-6910


Control Ball Valves
VBF2 Two-way Flanged Control Ball Valve

Controls
Home
The VBF2 Two-Way Ball Valve Assemblies, with and without
actuators, control hot and chilled water with glycol solutions up to
50% in closed loop heating, ventilating, and air conditioning
(HVAC) systems to provide two-position or modulating functions.
These valve assemblies can be ordered with or without factory-
mounted non-spring return or spring return direct-coupled
actuators (DCA).

Indoor Air Quality


• Sizes from 4 to 6 inch with ANSI Class 125 flanged connections.
• Equal percentage or linear flow characteristics.
• Choice of four, factory-installed actuation control schemes: Floating,
Modulating (2-10 V), Spring Return 24V 2-Position, Spring Return
Modulating/Floating.
• Field configurable for normally open or normally
• closed fail-safe position.
• Removable manual operating handle to control valve
• during installation or in an event of power failure.

Combustion Controls
• ANSI Class IV leakage specification (0.01% of Cv).
• Optional NEMA 3R (IP54) rated enclosure for outdoor applications.

Residential
• Option of four actuator mounting positions on the valve.
• Wide range of Cv choices from 91 to 650.
• Valve ball and stem 316 stainless steel.

Dimensions in inches (millimeters)


Valve Type: Control Ball Valve
Body Pattern: Two-way
Connection Type: Flanged

Hydronic Controls
Flow Characteristic: Equal Percentage
Controlled Fluid: Chilled or hot water with up to 50% Glycol. Not for
use with steam or fuels.
Leakage Rating: ANSI Class IV (0.01% of Cv maximum)
Maximum Safe Operating Pressure: 240 psi (1655 kPa)
Maximum Differential Pressure Ratings (Close-off):
70 psi (483 kPa)
Fluid Temperature Range: -22 F to +250 F (-30 C to +121 F)
Materials
(Body): Cast Iron

Controls
(Stem): 316 Stainless Steel

Water
E (Seat): Teflon®
(Plug/Ball/Disc): 316 stainless steel

Building Automation
B

A
C

Components
Commercial
Size Model A B C D (depth) E Wt.
(in.) Number in. in. in. (not shown) in. lb
(mm) (mm) (mm) in. (mm) (mm) (kg)
4 VBF2J 11 9 13-1/4 9 18-3/4 65
(278) (229) (337) (229) (476) (31)
5 VBF2K 12-3/8 10 14-1/4 10 19 75
(352) (254) (362) (254) (483) (34)
Pneumatic Controls

6 VBF2L 13-7/8 11 15-1/8 11 19-7/8 90


(352) (278) (384) (278) (505) (41)

M13732
Industrial Combustion
Controls

70-6910 567
Control Ball Valves
Valve Size Flow Capacity
Weather
Product Number (inch) DN (Cv) (Kv) Actuation Enclosure
VBF2JS1SRA 4 in. DN100 91 Cv 78 kvs Non-Spring Return Floating NEMA 3R
VBF2JS1SRB 4 in. DN100 91 Cv 78 kvs Non-Spring Return Modulating NEMA 3R
VBF2JS1SRC 4 in. DN100 91 Cv 78 kvs Spring Return 2-Position, 24Vac NEMA 3R
VBF2JS1SRD 4 in. DN100 91 Cv 78 kvs Spring Return Floating/Modulating NEMA 3R
VBF2JS1S0A 4 in. DN100 91 Cv 78 kvs Non-Spring Return Floating None
VBF2JS1S0B 4 in. DN100 91 Cv 78 kvs Non-Spring Return Modulating None
VBF2JS1S0C 4 in. DN100 91 Cv 78 kvs Spring Return 2-Position, 24Vac None
VBF2JS1S0D 4 in. DN100 91 Cv 78 kvs Spring Return Floating/Modulating None
VBF2JS1S0X 4 in. DN100 91 Cv 78 kvs No pre-assembled actuator None
VBF2JT1SRA 4 in. DN100 118 Cv 101 kvs Non-Spring Return Floating NEMA 3R
VBF2JT1SRB 4 in. DN100 118 Cv 101 kvs Non-Spring Return Modulating NEMA 3R
VBF2JT1SRC 4 in. DN100 118 Cv 101 kvs Spring Return 2-Position, 24Vac NEMA 3R
VBF2JT1SRD 4 in. DN100 118 Cv 101 kvs Spring Return Floating/Modulating NEMA 3R
VBF2JT1S0A 4 in. DN100 118 Cv 101 kvs Non-Spring Return Floating None
VBF2JT1S0B 4 in. DN100 118 Cv 101 kvs Non-Spring Return Modulating None
VBF2JT1S0C 4 in. DN100 118 Cv 101 kvs Spring Return 2-Position, 24Vac None
VBF2JT1S0D 4 in. DN100 118 Cv 101 kvs Spring Return Floating/Modulating None
VBF2JT1S0X 4 in. DN100 118 Cv 101 kvs No pre-assembled actuator None
VBF2JU1SRA 4 in. DN100 152 Cv 131 kvs Non-Spring Return Floating NEMA 3R
VBF2JU1SRB 4 in. DN100 152 Cv 131 kvs Non-Spring Return Modulating NEMA 3R
VBF2JU1SRC 4 in. DN100 152 Cv 131 kvs Spring Return 2-Position, 24Vac NEMA 3R
VBF2JU1SRD 4 in. DN100 152 Cv 131 kvs Spring Return Floating/Modulating NEMA 3R
VBF2JU1S0A 4 in. DN100 152 Cv 131 kvs Non-Spring Return Floating None
VBF2JU1S0B 4 in. DN100 152 Cv 131 kvs Non-Spring Return Modulating None
VBF2JU1S0C 4 in. DN100 152 Cv 131 kvs Spring Return 2-Position, 24Vac None
VBF2JU1S0D 4 in. DN100 152 Cv 131 kvs Spring Return Floating/Modulating None
VBF2JU1S0X 4 in. DN100 152 Cv 131 kvs No pre-assembled actuator None
VBF2J11SRA 4 in. DN100 197 Cv 169 kvs Non-Spring Return Floating NEMA 3R
VBF2J11SRB 4 in. DN100 197 Cv 169 kvs Non-Spring Return Modulating NEMA 3R
VBF2J11SRC 4 in. DN100 197 Cv 169 kvs Spring Return 2-Position, 24Vac NEMA 3R
VBF2J11SRD 4 in. DN100 197 Cv 169 kvs Spring Return Floating/Modulating NEMA 3R
VBF2J11S0A 4 in. DN100 197 Cv 169 kvs Non-Spring Return Floating None
VBF2J11S0B 4 in. DN100 197 Cv 169 kvs Non-Spring Return Modulating None
VBF2J11S0C 4 in. DN100 197 Cv 169 kvs Spring Return 2-Position, 24Vac None
VBF2J11S0D 4 in. DN100 197 Cv 169 kvs Spring Return Floating/Modulating None
VBF2J11S0X 4 in. DN100 197 Cv 169 kvs No pre-assembled actuator None
VBF2J21SRA 4 in. DN100 254 Cv 218 kvs Non-Spring Return Floating NEMA 3R
VBF2J21SRB 4 in. DN100 254 Cv 218 kvs Non-Spring Return Modulating NEMA 3R
VBF2J21SRC 4 in. DN100 254 Cv 218 kvs Spring Return 2-Position, 24Vac NEMA 3R
VBF2J21SRD 4 in. DN100 254 Cv 218 kvs Spring Return Floating/Modulating NEMA 3R
VBF2J21S0A 4 in. DN100 254 Cv 218 kvs Non-Spring Return Floating None
VBF2J21S0B 4 in. DN100 254 Cv 218 kvs Non-Spring Return Modulating None
VBF2J21S0C 4 in. DN100 254 Cv 218 kvs Spring Return 2-Position, 24Vac None
VBF2J21S0D 4 in. DN100 254 Cv 218 kvs Spring Return Floating/Modulating None
VBF2J21S0X 4 in. DN100 254 Cv 218 kvs No pre-assembled actuator None
VBF2KU1SRA 5 in. DN125 144 Cv 124 kvs Non-Spring Return Floating NEMA 3R
VBF2KU1SRB 5 in. DN125 144 Cv 124 kvs Non-Spring Return Modulating NEMA 3R
VBF2KU1SRC 5 in. DN125 144 Cv 124 kvs Spring Return 2-Position, 24Vac NEMA 3R
VBF2KU1SRD 5 in. DN125 144 Cv 124 kvs Spring Return Floating/Modulating NEMA 3R
VBF2KU1S0A 5 in. DN125 144 Cv 124 kvs Non-Spring Return Floating None
VBF2KU1S0B 5 in. DN125 144 Cv 124 kvs Non-Spring Return Modulating None
VBF2KU1S0C 5 in. DN125 144 Cv 124 kvs Spring Return 2-Position, 24Vac None
VBF2KU1S0D 5 in. DN125 144 Cv 124 kvs Spring Return Floating/Modulating None
VBF2KU1S0X 5 in. DN125 144 Cv 124 kvs No pre-assembled actuator None
VBF2K11SRA 5 in. DN125 185 Cv 159 kvs Non-Spring Return Floating NEMA 3R
VBF2K11SRB 5 in. DN125 185 Cv 159 kvs Non-Spring Return Modulating NEMA 3R
VBF2K11SRC 5 in. DN125 185 Cv 159 kvs Spring Return 2-Position, 24Vac NEMA 3R

568 customer.honeywell.com 70-6910


Control Ball Valves

Controls
Valve Size Flow Capacity

Home
Weather
Product Number (inch) DN (Cv) (Kv) Actuation Enclosure
VBF2K11SRD 5 in. DN125 185 Cv 159 kvs Spring Return Floating/Modulating NEMA 3R
VBF2K11S0A 5 in. DN125 185 Cv 159 kvs Non-Spring Return Floating None
VBF2K11S0B 5 in. DN125 185 Cv 159 kvs Non-Spring Return Modulating None
VBF2K11S0C 5 in. DN125 185 Cv 159 kvs Spring Return 2-Position, 24Vac None

Indoor Air Quality


VBF2K11S0D 5 in. DN125 185 Cv 159 kvs Spring Return Floating/Modulating None
VBF2K11S0X 5 in. DN125 185 Cv 159 kvs No pre-assembled actuator None
VBF2K21SRA 5 in. DN125 240 Cv 206 kvs Non-Spring Return Floating NEMA 3R
VBF2K21SRB 5 in. DN125 240 Cv 206 kvs Non-Spring Return Modulating NEMA 3R
VBF2K21SRC 5 in. DN125 240 Cv 206 kvs Spring Return 2-Position, 24Vac NEMA 3R
VBF2K21SRD 5 in. DN125 240 Cv 206 kvs Spring Return Floating/Modulating NEMA 3R
VBF2K21S0A 5 in. DN125 240 Cv 206 kvs Non-Spring Return Floating None

Combustion Controls
VBF2K21S0B 5 in. DN125 240 Cv 206 kvs Non-Spring Return Modulating None

Residential
VBF2K21S0C 5 in. DN125 240 Cv 206 kvs Spring Return 2-Position, 24Vac None
VBF2K21S0D 5 in. DN125 240 Cv 206 kvs Spring Return Floating/Modulating None
VBF2K21S0X 5 in. DN125 240 Cv 206 kvs No pre-assembled actuator None
VBF2K31SRA 5 in. DN125 309 Cv 266 kvs Non-Spring Return Floating NEMA 3R
VBF2K31SRB 5 in. DN125 309 Cv 266 kvs Non-Spring Return Modulating NEMA 3R
VBF2K31SRC 5 in. DN125 309 Cv 266 kvs Spring Return 2-Position, 24Vac NEMA 3R

Hydronic Controls
VBF2K31SRD 5 in. DN125 309 Cv 266 kvs Spring Return Floating/Modulating NEMA 3R
VBF2K31S0A 5 in. DN125 309 Cv 266 kvs Non-Spring Return Floating None
VBF2K31S0B 5 in. DN125 309 Cv 266 kvs Non-Spring Return Modulating None
VBF2K31S0C 5 in. DN125 309 Cv 266 kvs Spring Return 2-Position, 24Vac None
VBF2K31S0D 5 in. DN125 309 Cv 266 kvs Spring Return Floating/Modulating None
VBF2K31S0X 5 in. DN125 309 Cv 266 kvs No pre-assembled actuator None
VBF2K41SRA 5 in. DN125 400 Cv 344 kvs Non-Spring Return Floating NEMA 3R
VBF2K41SRB 5 in. DN125 400 Cv 344 kvs Non-Spring Return Modulating NEMA 3R
VBF2K41SRC 5 in. DN125 400 Cv 344 kvs Spring Return 2-Position, 24Vac NEMA 3R

Controls
Water
VBF2K41S0A 5 in. DN125 400 Cv 344 kvs Non-Spring Return Floating None
VBF2K41S0B 5 in. DN125 400 Cv 344 kvs Non-Spring Return Modulating None
VBF2K41S0C 5 in. DN125 400 Cv 344 kvs Spring Return 2-Position, 24Vac None
VBF2K41S0X 5 in. DN125 400 Cv 344 kvs No pre-assembled actuator None
VBF2L11SRA 6 in. DN150 208 Cv 179 kvs Non-Spring Return Floating NEMA 3R
VBF2L11SRB 6 in. DN150 208 Cv 179 kvs Non-Spring Return Modulating NEMA 3R

Building Automation
VBF2L11SRC 6 in. DN150 208 Cv 179 kvs Spring Return 2-Position, 24Vac NEMA 3R
VBF2L11SRD 6 in. DN150 208 Cv 179 kvs Spring Return Floating/Modulating NEMA 3R
VBF2L11S0A 6 in. DN150 208 Cv 179 kvs Non-Spring Return Floating None
VBF2L11S0B 6 in. DN150 208 Cv 179 kvs Non-Spring Return Modulating None
VBF2L11S0C 6 in. DN150 208 Cv 179 kvs Spring Return 2-Position, 24Vac None
VBF2L11S0D 6 in. DN150 208 Cv 179 kvs Spring Return Floating/Modulating None
VBF2L11S0X 6 in. DN150 208 Cv 179 kvs No pre-assembled actuator None
VBF2L21SRA 6 in. DN150 268 Cv 230 kvs Non-Spring Return Floating NEMA 3R

Components
Commercial
VBF2L21SRB 6 in. DN150 268 Cv 230 kvs Non-Spring Return Modulating NEMA 3R
VBF2L21SRC 6 in. DN150 268 Cv 230 kvs Spring Return 2-Position, 24Vac NEMA 3R
VBF2L21SRD 6 in. DN150 268 Cv 230 kvs Spring Return Floating/Modulating NEMA 3R
VBF2L21S0A 6 in. DN150 268 Cv 230 kvs Non-Spring Return Floating None
VBF2L21S0B 6 in. DN150 268 Cv 230 kvs Non-Spring Return Modulating None
VBF2L21S0C 6 in. DN150 268 Cv 230 kvs Spring Return 2-Position, 24Vac None
Pneumatic Controls

VBF2L21S0D 6 in. DN150 268 Cv 230 kvs Spring Return Floating/Modulating None
VBF2L21S0X 6 in. DN150 268 Cv 230 kvs No pre-assembled actuator None
VBF2L41SRA 6 in. DN150 346 Cv 298 kvs Non-Spring Return Floating NEMA 3R
VBF2L41SRB 6 in. DN150 346 Cv 298 kvs Non-Spring Return Modulating NEMA 3R
VBF2L41SRC 6 in. DN150 346 Cv 298 kvs Spring Return 2-Position, 24Vac NEMA 3R
VBF2L41S0A 6 in. DN150 346 Cv 298 kvs Non-Spring Return Floating None
VBF2L41S0B 6 in. DN150 346 Cv 298 kvs Non-Spring Return Modulating None
Industrial Combustion

VBF2L41S0C 6 in. DN150 346 Cv 298 kvs Spring Return 2-Position, 24Vac None
VBF2L41S0X 6 in. DN150 346 Cv 298 kvs No pre-assembled actuator None
Controls

VBF2L51SRA 6 in. DN150 441 Cv 379 kvs Non-Spring Return Floating NEMA 3R

70-6910 569
Control Ball Valves
Valve Size Flow Capacity
Weather
Product Number (inch) DN (Cv) (Kv) Actuation Enclosure
VBF2L51SRB 6 in. DN150 441 Cv 379 kvs Non-Spring Return Modulating NEMA 3R
VBF2L51SRC 6 in. DN150 441 Cv 379 kvs Spring Return 2-Position, 24Vac NEMA 3R
VBF2L51S0A 6 in. DN150 441 Cv 379 kvs Non-Spring Return Floating None
VBF2L51S0B 6 in. DN150 441 Cv 379 kvs Non-Spring Return Modulating None
VBF2L51S0C 6 in. DN150 441 Cv 379 kvs Spring Return 2-Position, 24Vac None
VBF2L51S0X 6 in. DN150 441 Cv 379 kvs No pre-assembled actuator None
VBF2L61SRA 6 in. DN150 577 Cv 496 kvs Non-Spring Return Floating NEMA 3R
VBF2L61SRB 6 in. DN150 577 Cv 496 kvs Non-Spring Return Modulating NEMA 3R
VBF2L61SRC 6 in. DN150 577 Cv 496 kvs Spring Return 2-Position, 24Vac NEMA 3R
VBF2L61S0A 6 in. DN150 577 Cv 496 kvs Non-Spring Return Floating None
VBF2L61S0B 6 in. DN150 577 Cv 496 kvs Non-Spring Return Modulating None
VBF2L61S0C 6 in. DN150 577 Cv 496 kvs Spring Return 2-Position, 24Vac None
VBF2L61S0X 6 in. DN150 577 Cv 496 kvs No pre-assembled actuator None
VBF2L71SRA 6 in. DN150 650 Cv 559 kvs Non-Spring Return Floating NEMA 3R
VBF2L71SRB 6 in. DN150 650 Cv 559 kvs Non-Spring Return Modulating NEMA 3R
VBF2L71SRC 6 in. DN150 650 Cv 559 kvs Spring Return 2-Position, 24Vac NEMA 3R
VBF2L71S0A 6 in. DN150 650 Cv 559 kvs Non-Spring Return Floating None
VBF2L71S0B 6 in. DN150 650 Cv 559 kvs Non-Spring Return Modulating None
VBF2L71S0C 6 in. DN150 650 Cv 559 kvs Spring Return 2-Position, 24Vac None
VBF2L71S0X 6 in. DN150 650 Cv 559 kvs No pre-assembled actuator None

570 customer.honeywell.com 70-6910


Control Ball Valves
VBF3 Three-way Flanged Control Ball Valve

Controls
Home
50% in closed loop heating, ventilating, and air conditioning
(HVAC) systems to provide two-position or modulating functions.
These valve assemblies can be ordered with or without factory-
mounted non-spring return or spring return direct-coupled
actuators (DCA).
• Sizes from 4 to 6 inch with ANSI Class 125 flanged connections.
• Equal percentage or linear flow characteristics.

Indoor Air Quality


• Choice of four, factory-installed actuation control schemes: Floating,
Modulating (2-10 V), Spring Return 24V 2-Position, Spring Return
Modulating/Floating.
• Field configurable for normally open or normally
• closed fail-safe position.
• Removable manual operating handle to control valve
• during installation or in an event of power failure.
• ANSI Class IV A-port seat leakage (0.01% of Cv).
• Optional NEMA 3R (IP54) rated enclosure for outdoor applications.

Combustion Controls
• Option of four actuator mounting positions on the valve.
• Wide range of Cv choices from 91 to 650.

Residential
• Valve ball and stem 316 stainless steel.
The VBF3 Three-Way Ball Valve Assemblies, with and without • Non-isolating mixing or diverting control.
actuators, control hot and chilled water with glycol solutions up to

Dimensions in inches (millimeters)


Valve Type: Control Ball Valve
Body Pattern: Three-way
Connection Type: Flanged

Hydronic Controls
Flow Characteristic: Linear (B-AB); Equal Percentage (A-AB)
Controlled Fluid: Chilled or hot water with up to 50% Glycol. Not for
use with steam or fuels.
Leakage Rating: ANSI Class IV (A port only) B port ~2% leakage
Maximum Safe Operating Pressure: 240 psi (1655 kPa)
Maximum Differential Pressure Ratings (Close-off): 70 psi (483 kPa)
Fluid Temperature Range: -22 F to +250 F (-30 C to +121 F)
Materials
(Body): Cast Iron
(Stem): 316 Stainless Steel

Controls
(Seat): Teflon®

Water
AB PORT A PORT
(Plug/Ball/Disc): 316 stainless steel
E

B PORT

Building Automation
B

A
C

Components
Commercial
Size Model A B C D (depth) E Wt.
(in.) Number in. in. in. (not shown) in. lb
(mm) (mm) (mm) in. (mm) (mm) (kg)
4 VBF3J 11-7/8 9 14-1/8 10-3/8 18-1/2 75
(278) (229) (337) (229) (470) (34)
5 VBF3K 13-7/8 10 15-1/8 12 19-3/8 90
(352) (254) (362) (254) (483) (41)
Pneumatic Controls

6 VBF3L 15-7/8 11 16-1/8 13-3/8 20-1/2 105


(403) (278) (410) (521) (521) (48)

M13733A
Industrial Combustion
Controls

70-6910 571
Control Ball Valves
Valve Size Flow Capacity
Weather
Product Number (inch) DN (Cv) (Kv) Actuation Enclosure
VBF3JS1SRA 4 in. DN100 91 Cv 78 kvs Non-Spring Return Floating NEMA 3R
VBF3JS1SRB 4 in. DN100 91 Cv 78 kvs Non-Spring Return Modulating NEMA 3R
VBF3JS1SRC 4 in. DN100 91 Cv 78 kvs Spring Return 2-Position, 24Vac NEMA 3R
VBF3JS1SRD 4 in. DN100 91 Cv 78 kvs Spring Return Floating/Modulating NEMA 3R
VBF3JS1S0A 4 in. DN100 91 Cv 78 kvs Non-Spring Return Floating None
VBF3JS1S0B 4 in. DN100 91 Cv 78 kvs Non-Spring Return Modulating None
VBF3JS1S0C 4 in. DN100 91 Cv 78 kvs Spring Return 2-Position, 24Vac None
VBF3JS1S0D 4 in. DN100 91 Cv 78 kvs Spring Return Floating/Modulating None
VBF3JS1S0X 4 in. DN100 91 Cv 78 kvs No pre-assembled actuator None
VBF3JT1SRA 4 in. DN100 118 Cv 101 kvs Non-Spring Return Floating NEMA 3R
VBF3JT1SRB 4 in. DN100 118 Cv 101 kvs Non-Spring Return Modulating NEMA 3R
VBF3JT1SRC 4 in. DN100 118 Cv 101 kvs Spring Return 2-Position, 24Vac NEMA 3R
VBF3JT1SRD 4 in. DN100 118 Cv 101 kvs Spring Return Floating/Modulating NEMA 3R
VBF3JT1S0A 4 in. DN100 118 Cv 101 kvs Non-Spring Return Floating None
VBF3JT1S0B 4 in. DN100 118 Cv 101 kvs Non-Spring Return Modulating None
VBF3JT1S0C 4 in. DN100 118 Cv 101 kvs Spring Return 2-Position, 24Vac None
VBF3JT1S0D 4 in. DN100 118 Cv 101 kvs Spring Return Floating/Modulating None
VBF3JT1S0X 4 in. DN100 118 Cv 101 kvs No pre-assembled actuator None
VBF3JU1SRA 4 in. DN100 152 Cv 131 kvs Non-Spring Return Floating NEMA 3R
VBF3JU1SRB 4 in. DN100 152 Cv 131 kvs Non-Spring Return Modulating NEMA 3R
VBF3JU1SRC 4 in. DN100 152 Cv 131 kvs Spring Return 2-Position, 24Vac NEMA 3R
VBF3JU1SRD 4 in. DN100 152 Cv 131 kvs Spring Return Floating/Modulating NEMA 3R
VBF3JU1S0A 4 in. DN100 152 Cv 131 kvs Non-Spring Return Floating None
VBF3JU1S0B 4 in. DN100 152 Cv 131 kvs Non-Spring Return Modulating None
VBF3JU1S0C 4 in. DN100 152 Cv 131 kvs Spring Return 2-Position, 24Vac None
VBF3JU1S0D 4 in. DN100 152 Cv 131 kvs Spring Return Floating/Modulating None
VBF3JU1S0X 4 in. DN100 152 Cv 131 kvs No pre-assembled actuator None
VBF3J11SRA 4 in. DN100 197 Cv 169 kvs Non-Spring Return Floating NEMA 3R
VBF3J11SRB 4 in. DN100 197 Cv 169 kvs Non-Spring Return Modulating NEMA 3R
VBF3J11SRC 4 in. DN100 197 Cv 169 kvs Spring Return 2-Position, 24Vac NEMA 3R
VBF3J11SRD 4 in. DN100 197 Cv 169 kvs Spring Return Floating/Modulating NEMA 3R
VBF3J11S0A 4 in. DN100 197 Cv 169 kvs Non-Spring Return Floating None
VBF3J11S0B 4 in. DN100 197 Cv 169 kvs Non-Spring Return Modulating None
VBF3J11S0C 4 in. DN100 197 Cv 169 kvs Spring Return 2-Position, 24Vac None
VBF3J11S0D 4 in. DN100 197 Cv 169 kvs Spring Return Floating/Modulating None
VBF3J11S0X 4 in. DN100 197 Cv 169 kvs No pre-assembled actuator None
VBF3J21SRA 4 in. DN100 254 Cv 218 kvs Non-Spring Return Floating NEMA 3R
VBF3J21SRB 4 in. DN100 254 Cv 218 kvs Non-Spring Return Modulating NEMA 3R
VBF3J21SRC 4 in. DN100 254 Cv 218 kvs Spring Return 2-Position, 24Vac NEMA 3R
VBF3J21SRD 4 in. DN100 254 Cv 218 kvs Spring Return Floating/Modulating NEMA 3R
VBF3J21S0A 4 in. DN100 254 Cv 218 kvs Non-Spring Return Floating None
VBF3J21S0B 4 in. DN100 254 Cv 218 kvs Non-Spring Return Modulating None
VBF3J21S0C 4 in. DN100 254 Cv 218 kvs Spring Return 2-Position, 24Vac None
VBF3J21S0D 4 in. DN100 254 Cv 218 kvs Spring Return Floating/Modulating None
VBF3J21S0X 4 in. DN100 254 Cv 218 kvs No pre-assembled actuator None
VBF3J31SRA 4 in. DN100 327 Cv 281 kvs Non-Spring Return Floating NEMA 3R
VBF3J31SRB 4 in. DN100 327 Cv 281 kvs Non-Spring Return Modulating NEMA 3R
VBF3J31SRC 4 in. DN100 327 Cv 281 kvs Spring Return 2-Position, 24Vac NEMA 3R
VBF3J31SRD 4 in. DN100 327 Cv 281 kvs Spring Return Floating/Modulating NEMA 3R
VBF3J31S0A 4 in. DN100 327 Cv 281 kvs Non-Spring Return Floating None
VBF3J31S0B 4 in. DN100 327 Cv 281 kvs Non-Spring Return Modulating None
VBF3J31S0C 4 in. DN100 327 Cv 281 kvs Spring Return 2-Position, 24Vac None
VBF3J31S0D 4 in. DN100 327 Cv 281 kvs Spring Return Floating/Modulating None
VBF3J31S0X 4 in. DN100 327 Cv 281 kvs No pre-assembled actuator None
VBF3KU1SRA 5 in. DN125 144 Cv 124 kvs Non-Spring Return Floating NEMA 3R
VBF3KU1SRB 5 in. DN125 144 Cv 124 kvs Non-Spring Return Modulating NEMA 3R
VBF3KU1SRC 5 in. DN125 144 Cv 124 kvs Spring Return 2-Position, 24Vac NEMA 3R

572 customer.honeywell.com 70-6910


Control Ball Valves

Controls
Valve Size Flow Capacity

Home
Weather
Product Number (inch) DN (Cv) (Kv) Actuation Enclosure
VBF3KU1SRD 5 in. DN125 144 Cv 124 kvs Spring Return Floating/Modulating NEMA 3R
VBF3KU1S0A 5 in. DN125 144 Cv 124 kvs Non-Spring Return Floating None
VBF3KU1S0B 5 in. DN125 144 Cv 124 kvs Non-Spring Return Modulating None
VBF3KU1S0C 5 in. DN125 144 Cv 124 kvs Spring Return 2-Position, 24Vac None

Indoor Air Quality


VBF3KU1S0D 5 in. DN125 144 Cv 124 kvs Spring Return Floating/Modulating None
VBF3KU1S0X 5 in. DN125 144 Cv 124 kvs No pre-assembled actuator None
VBF3K11SRA 5 in. DN125 185 Cv 159 kvs Non-Spring Return Floating NEMA 3R
VBF3K11SRB 5 in. DN125 185 Cv 159 kvs Non-Spring Return Modulating NEMA 3R
VBF3K11SRC 5 in. DN125 185 Cv 159 kvs Spring Return 2-Position, 24Vac NEMA 3R
VBF3K11SRD 5 in. DN125 185 Cv 159 kvs Spring Return Floating/Modulating NEMA 3R
VBF3K11S0A 5 in. DN125 185 Cv 159 kvs Non-Spring Return Floating None

Combustion Controls
VBF3K11S0B 5 in. DN125 185 Cv 159 kvs Non-Spring Return Modulating None

Residential
VBF3K11S0C 5 in. DN125 185 Cv 159 kvs Spring Return 2-Position, 24Vac None
VBF3K11S0D 5 in. DN125 185 Cv 159 kvs Spring Return Floating/Modulating None
VBF3K11S0X 5 in. DN125 185 Cv 159 kvs No pre-assembled actuator None
VBF3K21SRA 5 in. DN125 240 Cv 206 kvs Non-Spring Return Floating NEMA 3R
VBF3K21SRB 5 in. DN125 240 Cv 206 kvs Non-Spring Return Modulating NEMA 3R
VBF3K21SRC 5 in. DN125 240 Cv 206 kvs Spring Return 2-Position, 24Vac NEMA 3R

Hydronic Controls
VBF3K21SRD 5 in. DN125 240 Cv 206 kvs Spring Return Floating/Modulating NEMA 3R
VBF3K21S0A 5 in. DN125 240 Cv 206 kvs Non-Spring Return Floating None
VBF3K21S0B 5 in. DN125 240 Cv 206 kvs Non-Spring Return Modulating None
VBF3K21S0C 5 in. DN125 240 Cv 206 kvs Spring Return 2-Position, 24Vac None
VBF3K21S0D 5 in. DN125 240 Cv 206 kvs Spring Return Floating/Modulating None
VBF3K21S0X 5 in. DN125 240 Cv 206 kvs No pre-assembled actuator None
VBF3K31SRA 5 in. DN125 309 Cv 266 kvs Non-Spring Return Floating NEMA 3R
VBF3K31SRB 5 in. DN125 309 Cv 266 kvs Non-Spring Return Modulating NEMA 3R
VBF3K31SRC 5 in. DN125 309 Cv 266 kvs Spring Return 2-Position, 24Vac NEMA 3R

Controls
Water
VBF3K31SRD 5 in. DN125 309 Cv 266 kvs Spring Return Floating/Modulating NEMA 3R
VBF3K31S0A 5 in. DN125 309 Cv 266 kvs Non-Spring Return Floating None
VBF3K31S0B 5 in. DN125 309 Cv 266 kvs Non-Spring Return Modulating None
VBF3K31S0C 5 in. DN125 309 Cv 266 kvs Spring Return 2-Position, 24Vac None
VBF3K31S0D 5 in. DN125 309 Cv 266 kvs Spring Return Floating/Modulating None
VBF3K31S0X 5 in. DN125 309 Cv 266 kvs No pre-assembled actuator None

Building Automation
VBF3K41SRA 5 in. DN125 400 Cv 344 kvs Non-Spring Return Floating NEMA 3R
VBF3K41SRB 5 in. DN125 400 Cv 344 kvs Non-Spring Return Modulating NEMA 3R
VBF3K41SRC 5 in. DN125 400 Cv 344 kvs Spring Return 2-Position, 24Vac NEMA 3R
VBF3K41S0A 5 in. DN125 400 Cv 344 kvs Non-Spring Return Floating None
VBF3K41S0B 5 in. DN125 400 Cv 344 kvs Non-Spring Return Modulating None
VBF3K41S0C 5 in. DN125 400 Cv 344 kvs Spring Return 2-Position, 24Vac None
VBF3K41S0X 5 in. DN125 400 Cv 344 kvs No pre-assembled actuator None
VBF3L11SRA 6 in. DN150 208 Cv 179 kvs Non-Spring Return Floating NEMA 3R

Components
Commercial
VBF3L11SRB 6 in. DN150 208 Cv 179 kvs Non-Spring Return Modulating NEMA 3R
VBF3L11SRC 6 in. DN150 208 Cv 179 kvs Spring Return 2-Position, 24Vac NEMA 3R
VBF3L11SRD 6 in. DN150 208 Cv 179 kvs Spring Return Floating/Modulating NEMA 3R
VBF3L11S0A 6 in. DN150 208 Cv 179 kvs Non-Spring Return Floating None
VBF3L11S0B 6 in. DN150 208 Cv 179 kvs Non-Spring Return Modulating None
VBF3L11S0C 6 in. DN150 208 Cv 179 kvs Spring Return 2-Position, 24Vac None
Pneumatic Controls

VBF3L11S0D 6 in. DN150 208 Cv 179 kvs Spring Return Floating/Modulating None
VBF3L11S0X 6 in. DN150 208 Cv 179 kvs No pre-assembled actuator None
VBF3L21SRA 6 in. DN150 268 Cv 230 kvs Non-Spring Return Floating NEMA 3R
VBF3L21SRB 6 in. DN150 268 Cv 230 kvs Non-Spring Return Modulating NEMA 3R
VBF3L21SRC 6 in. DN150 268 Cv 230 kvs Spring Return 2-Position, 24Vac NEMA 3R
VBF3L21SRD 6 in. DN150 268 Cv 230 kvs Spring Return Floating/Modulating NEMA 3R
VBF3L21S0A 6 in. DN150 268 Cv 230 kvs Non-Spring Return Floating None
Industrial Combustion

VBF3L21S0B 6 in. DN150 268 Cv 230 kvs Non-Spring Return Modulating None
VBF3L21S0C 6 in. DN150 268 Cv 230 kvs Spring Return 2-Position, 24Vac None
Controls

VBF3L21S0D 6 in. DN150 268 Cv 230 kvs Spring Return Floating/Modulating None

70-6910 573
Control Ball Valves
Valve Size Flow Capacity
Weather
Product Number (inch) DN (Cv) (Kv) Actuation Enclosure
VBF3L21S0X 6 in. DN150 268 Cv 230 kvs No pre-assembled actuator None
VBF3L41SRA 6 in. DN150 346 Cv 298 kvs Non-Spring Return Floating NEMA 3R
VBF3L41SRB 6 in. DN150 346 Cv 298 kvs Non-Spring Return Modulating NEMA 3R
VBF3L41SRC 6 in. DN150 346 Cv 298 kvs Spring Return 2-Position, 24Vac NEMA 3R
VBF3L41S0A 6 in. DN150 346 Cv 298 kvs Non-Spring Return Floating None
VBF3L41S0B 6 in. DN150 346 Cv 298 kvs Non-Spring Return Modulating None
VBF3L41S0C 6 in. DN150 346 Cv 298 kvs Spring Return 2-Position, 24Vac None
VBF3L41S0X 6 in. DN150 346 Cv 298 kvs No pre-assembled actuator None
VBF3L51SRA 6 in. DN150 441 Cv 379 kvs Non-Spring Return Floating NEMA 3R
VBF3L51SRB 6 in. DN150 441 Cv 379 kvs Non-Spring Return Modulating NEMA 3R
VBF3L51SRC 6 in. DN150 441 Cv 379 kvs Spring Return 2-Position, 24Vac NEMA 3R
VBF3L51S0A 6 in. DN150 441 Cv 379 kvs Non-Spring Return Floating None
VBF3L51S0B 6 in. DN150 441 Cv 379 kvs Non-Spring Return Modulating None
VBF3L51S0C 6 in. DN150 441 Cv 379 kvs Spring Return 2-Position, 24Vac None
VBF3L51S0X 6 in. DN150 441 Cv 379 kvs No pre-assembled actuator None
VBF3L61SRA 6 in. DN150 577 Cv 496 kvs Non-Spring Return Floating NEMA 3R
VBF3L61SRB 6 in. DN150 577 Cv 496 kvs Non-Spring Return Modulating NEMA 3R
VBF3L61SRC 6 in. DN150 577 Cv 496 kvs Spring Return 2-Position, 24Vac NEMA 3R
VBF3L61S0A 6 in. DN150 577 Cv 496 kvs Non-Spring Return Floating None
VBF3L61S0B 6 in. DN150 577 Cv 496 kvs Non-Spring Return Modulating None
VBF3L61S0C 6 in. DN150 577 Cv 496 kvs Spring Return 2-Position, 24Vac None
VBF3L61S0X 6 in. DN150 577 Cv 496 kvs No pre-assembled actuator None
VBF3L71SRA 6 in. DN150 650 Cv 559 kvs Non-Spring Return Floating NEMA 3R
VBF3L71SRB 6 in. DN150 650 Cv 559 kvs Non-Spring Return Modulating NEMA 3R
VBF3L71SRC 6 in. DN150 650 Cv 559 kvs Spring Return 2-Position, 24Vac NEMA 3R
VBF3L71S0A 6 in. DN150 650 Cv 559 kvs Non-Spring Return Floating None
VBF3L71S0B 6 in. DN150 650 Cv 559 kvs Non-Spring Return Modulating None
VBF3L71S0C 6 in. DN150 650 Cv 559 kvs Spring Return 2-Position, 24Vac None
VBF3L71S0X 6 in. DN150 650 Cv 559 kvs No pre-assembled actuator None

574 customer.honeywell.com 70-6910


Control Ball Valves
VBN2 Two-way Threaded Control Ball Valve

Controls
Home
The VBN2 Two-Way Control Ball Valves control hot and chilled
water with glycol solutions up to 50% in heating, ventilating, and
air conditioning (HVAC) systems to provide two-position or
modulating functions. These valve assemblies can be ordered with
or without factory-mounted non-spring return or spring return
direct-coupled actuators (DCA).
• Sizes from 1/2 to 3 inches with internal (female) NPT connections.

Indoor Air Quality


• Equal percentage or linear flow characteristics.
• Choice of four, factory-installed actuation control schemes: Floating,
Modulating (2-10 V), Spring Return 2-Position, Spring Return
Modulating/Floating.
• Field configurable for normally open or normally
• closed fail-safe position.
• Removable manual operating handle to control valve during
installation or in an event of power failure.
• ANSI Class IV seat leakage specification (0.01% of Cv).

Combustion Controls
• Optional NEMA 3R (IP54) rated enclosure for outdoor applications.
• Actuator can be mounted on the valve in any of four positions.

Residential
• Field-serviceable stem assembly.
• Wide Cv choices from 0.38 to 266.
• Nickel-chrome plated brass or 316 stainless steel ball and stem.
Dimensions in inches (millimeters)

Hydronic Controls
F
E D
B

A
C

Controls
Water
Pipe Model CV Dimensions inches (mm) Weight
Size No. A B C D E F lb (kg)
1/2" VBN2A 0.38, 0.68, 1.3, 2.0, 2.6, 4.7, 11.7 2-3/8 (60) 3-7/16 (87) 6-5/8 (168) 3 (76) 4 (102) 8-1/8 (206) 1 (0.5)
8.0 2-5/8 (67) 3-11/16 (94) 6-1/2 (165) 3 (76) 4 (102) 8-5/16 (211) 1 (0.5)
3/4" VBN2B 0.31, 0.63, 1.2, 2.5, 4.3, 7.4, 14.7 2-3/8 (60) 3-7/16 (87) 6-7/16 (164) 3 (76) 4 (102) 8-1/8 (206) 1 (0.5)
10.1, 29 2-5/8 (67) 3-11/16 (94) 6-1/2 (165) 3 (76) 4 (102) 8-5/16 (211) 1 (0.5)

Building Automation
1" VBN2C 9.0 3-3/4 (95) 3-11/16 (94) 7-1/16 (179) 3 (76) 4 (102) 8-5/16 (211) 1 (0.5)
4.4, 15.3, 54 3 (76) 3-15/16 (100) 6-3/4 (171) 3 (76) 4 (102) 8-11/16 (221) 1.4 (0.6)
26, 44 4-3/8 (111) 4-7/16 (113) 7-3/8 (187) 3 (76) 4 (102) 8-7/8 (225) 2.4 (1.1)
1-1/4" VBN2D 4.4, 8.3, 14.9, 25, 41 3 (76) 3-15/16 (100) 6-11/16 (170) 3 (76) 4 (102) 8-11/16 (221) 1.4 (0.6)
37, 102 3-5/8 (92) 4-7/16 (113) 7 (178) 3 (76) 4 (102) 9-1/16 (231) 2.4 (1.1)
1-1/2" VBN2E 23, 30, 74 3-3/8 (86) 3-15/16 (100) 6-15/16 (176) 3 (76) 4 (102) 9-1/16 (231) 2.4 (1.1)
41, 172 3-3/4 (95) 5-3/16 (132) 7-1/16 (179) 3 (76) 4 (102) 8-7/8 (225) 3.2 (1.5)
2" VBN2F 42, 108 4 (102) 5-3/16 (132) 7-3/16 (183) 3 (76) 4 (102) 8-7/8 (225) 3.2 (1.5)
57, 71, 100, 210, 266 4-3/8 (111) 5-3/4 (146) 7-7/16 (189) 3 (76) 4 (102) 10-1/2 (267) 5 (2.3)
2-1/2" VBN2G 45, 55, 72, 101, 162, 202 4-3/4 (121) 5-3/4 (146) 7-9/16 (192) 3 (76) 4 (102) 10-1/2 (267) 5.5 (2.5)

Components
Commercial
3" VBN2H 49, 63, 82, 124, 145 5 (127) 5-7/8 (149) 7-11/16 (195) 3 (76) 4 (102) 10-11/16 (271) 5.9 (2.7)

M13729A

Valve Type: Control Ball Valve Fluid Temperature Range: -22 F to +250 F (-30 C to +121 F)
Body Pattern: Two-way Materials
Connection Type: Female NPT (Body): Brass
Controlled Fluid: Chilled or hot water with up to 50% Glycol. Not for (Seat): Teflon® seals with EPDM O-rings
Pneumatic Controls

use with steam or fuels. (Flow Control Insert) : Noryl®


Leakage Rating: ANSI Class IV (0.01% of Cv maximum)
Maximum Safe Operating Pressure: 360 psi (2482 kPa)
Industrial Combustion
Controls

70-6910 575
Control Ball Valves
Valves with Equal Percentage Flow Characteristic

Maximum
Close-off
Weather
Valve Size Flow Capacity Materials Pressure
Enclo-
Product Number (inch) DN (Cv) (Kv) (Plug/Ball/Disc) (Stem) Actuation sure (psi) (kPa)
VBN2AB3PRA 1/2 in. DN15 0.38 Cv 0.33 kvs Nickel-plated brass ball Brass Non-Spring Return Floating NEMA 3R 130 psi 896 kPa
VBN2AB3PRB 1/2 in. DN15 0.38 Cv 0.33 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating NEMA 3R 130 psi 896 kPa
VBN2AB3PRC 1/2 in. DN15 0.38 Cv 0.33 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac NEMA 3R 130 psi 896 kPa
VBN2AB3PRD 1/2 in. DN15 0.38 Cv 0.33 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating NEMA 3R 130 psi 896 kPa
VBN2AB3SRA 1/2 in. DN15 0.38 Cv 0.33 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating NEMA 3R 130 psi 896 kPa
VBN2AB3SRB 1/2 in. DN15 0.38 Cv 0.33 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating NEMA 3R 130 psi 896 kPa
VBN2AB3SRC 1/2 in. DN15 0.38 Cv 0.33 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac NEMA 3R 130 psi 896 kPa
VBN2AB3SRD 1/2 in. DN15 0.38 Cv 0.33 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating NEMA 3R 130 psi 896 kPa
VBN2AB3P0A 1/2 in. DN15 0.38 Cv 0.33 kvs Nickel-plated brass ball Brass Non-Spring Return Floating None 130 psi 896 kPa
VBN2AB3P0B 1/2 in. DN15 0.38 Cv 0.33 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating None 130 psi 896 kPa
VBN2AB3P0C 1/2 in. DN15 0.38 Cv 0.33 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac None 130 psi 896 kPa
VBN2AB3P0D 1/2 in. DN15 0.38 Cv 0.33 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating None 130 psi 896 kPa
VBN2AB3P0X 1/2 in. DN15 0.38 Cv 0.33 kvs Nickel-plated brass ball Brass No pre-assembled actuator None 130 psi 896 kPa
VBN2AB3S0A 1/2 in. DN15 0.38 Cv 0.33 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating None 130 psi 896 kPa
VBN2AB3S0B 1/2 in. DN15 0.38 Cv 0.33 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating None 130 psi 896 kPa
VBN2AB3S0C 1/2 in. DN15 0.38 Cv 0.33 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac None 130 psi 896 kPa
VBN2AB3S0D 1/2 in. DN15 0.38 Cv 0.33 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating None 130 psi 896 kPa
VBN2AB3S0X 1/2 in. DN15 0.38 Cv 0.33 kvs 316 stainless steel 316 Stainless Steel No pre-assembled actuator None 130 psi 896 kPa
VBN2AD3PRA 1/2 in. DN15 0.68 Cv 0.58 kvs Nickel-plated brass ball Brass Non-Spring Return Floating NEMA 3R 130 psi 896 kPa
VBN2AD3PRB 1/2 in. DN15 0.68 Cv 0.58 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating NEMA 3R 130 psi 896 kPa
VBN2AD3PRC 1/2 in. DN15 0.68 Cv 0.58 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac NEMA 3R 130 psi 896 kPa
VBN2AD3PRD 1/2 in. DN15 0.68 Cv 0.58 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating NEMA 3R 130 psi 896 kPa
VBN2AD3SRA 1/2 in. DN15 0.68 Cv 0.58 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating NEMA 3R 130 psi 896 kPa
VBN2AD3SRB 1/2 in. DN15 0.68 Cv 0.58 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating NEMA 3R 130 psi 896 kPa
VBN2AD3SRC 1/2 in. DN15 0.68 Cv 0.58 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac NEMA 3R 130 psi 896 kPa
VBN2AD3SRD 1/2 in. DN15 0.68 Cv 0.58 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating NEMA 3R 130 psi 896 kPa
VBN2AD3P0A 1/2 in. DN15 0.68 Cv 0.58 kvs Nickel-plated brass ball Brass Non-Spring Return Floating None 130 psi 896 kPa
VBN2AD3P0B 1/2 in. DN15 0.68 Cv 0.58 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating None 130 psi 896 kPa
VBN2AD3P0C 1/2 in. DN15 0.68 Cv 0.58 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac None 130 psi 896 kPa
VBN2AD3P0D 1/2 in. DN15 0.68 Cv 0.58 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating None 130 psi 896 kPa
VBN2AD3P0X 1/2 in. DN15 0.68 Cv 0.58 kvs Nickel-plated brass ball Brass No pre-assembled actuator None 130 psi 896 kPa
VBN2AD3S0A 1/2 in. DN15 0.68 Cv 0.58 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating None 130 psi 896 kPa
VBN2AD3S0B 1/2 in. DN15 0.68 Cv 0.58 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating None 130 psi 896 kPa
VBN2AD3S0C 1/2 in. DN15 0.68 Cv 0.58 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac None 130 psi 896 kPa
VBN2AD3S0D 1/2 in. DN15 0.68 Cv 0.58 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating None 130 psi 896 kPa
VBN2AD3S0X 1/2 in. DN15 0.68 Cv 0.58 kvs 316 stainless steel 316 Stainless Steel No pre-assembled actuator None 130 psi 896 kPa
VBN2AE3PRA 1/2 in. DN15 1.3 Cv 1.1 kvs Nickel-plated brass ball Brass Non-Spring Return Floating NEMA 3R 130 psi 896 kPa
VBN2AE3PRB 1/2 in. DN15 1.3 Cv 1.1 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating NEMA 3R 130 psi 896 kPa
VBN2AE3PRC 1/2 in. DN15 1.3 Cv 1.1 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac NEMA 3R 130 psi 896 kPa
VBN2AE3PRD 1/2 in. DN15 1.3 Cv 1.1 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating NEMA 3R 130 psi 896 kPa
VBN2AE3SRA 1/2 in. DN15 1.3 Cv 1.1 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating NEMA 3R 130 psi 896 kPa
VBN2AE3SRB 1/2 in. DN15 1.3 Cv 1.1 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating NEMA 3R 130 psi 896 kPa
VBN2AE3SRC 1/2 in. DN15 1.3 Cv 1.1 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac NEMA 3R 130 psi 896 kPa
VBN2AE3SRD 1/2 in. DN15 1.3 Cv 1.1 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating NEMA 3R 130 psi 896 kPa
VBN2AE3P0A 1/2 in. DN15 1.3 Cv 1.1 kvs Nickel-plated brass ball Brass Non-Spring Return Floating None 130 psi 896 kPa
VBN2AE3P0B 1/2 in. DN15 1.3 Cv 1.1 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating None 130 psi 896 kPa
VBN2AE3P0C 1/2 in. DN15 1.3 Cv 1.1 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac None 130 psi 896 kPa
VBN2AE3P0D 1/2 in. DN15 1.3 Cv 1.1 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating None 130 psi 896 kPa
VBN2AE3P0X 1/2 in. DN15 1.3 Cv 1.1 kvs Nickel-plated brass ball Brass No pre-assembled actuator None 130 psi 896 kPa
VBN2AE3S0A 1/2 in. DN15 1.3 Cv 1.1 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating None 130 psi 896 kPa
VBN2AE3S0B 1/2 in. DN15 1.3 Cv 1.1 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating None 130 psi 896 kPa
VBN2AE3S0C 1/2 in. DN15 1.3 Cv 1.1 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac None 130 psi 896 kPa
VBN2AE3S0D 1/2 in. DN15 1.3 Cv 1.1 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating None 130 psi 896 kPa
VBN2AE3S0X 1/2 in. DN15 1.3 Cv 1.1 kvs 316 stainless steel 316 Stainless Steel No pre-assembled actuator None 130 psi 896 kPa
VBN2AF3PRA 1/2 in. DN15 2.0 Cv 1.7 kvs Nickel-plated brass ball Brass Non-Spring Return Floating NEMA 3R 130 psi 896 kPa
VBN2AF3PRB 1/2 in. DN15 2.0 Cv 1.7 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating NEMA 3R 130 psi 896 kPa
VBN2AF3PRC 1/2 in. DN15 2.0 Cv 1.7 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac NEMA 3R 130 psi 896 kPa

576 customer.honeywell.com 70-6910


Control Ball Valves

Controls
Maximum

Home
Close-off
Weather
Valve Size Flow Capacity Materials Pressure
Enclo-
Product Number (inch) DN (Cv) (Kv) (Plug/Ball/Disc) (Stem) Actuation sure (psi) (kPa)
VBN2AF3PRD 1/2 in. DN15 2.0 Cv 1.7 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating NEMA 3R 130 psi 896 kPa
VBN2AF3SRA 1/2 in. DN15 2.0 Cv 1.7 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating NEMA 3R 130 psi 896 kPa
VBN2AF3SRB 1/2 in. DN15 2.0 Cv 1.7 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating NEMA 3R 130 psi 896 kPa

Indoor Air Quality


VBN2AF3SRC 1/2 in. DN15 2.0 Cv 1.7 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac NEMA 3R 130 psi 896 kPa
VBN2AF3SRD 1/2 in. DN15 2.0 Cv 1.7 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating NEMA 3R 130 psi 896 kPa
VBN2AF3P0A 1/2 in. DN15 2.0 Cv 1.7 kvs Nickel-plated brass ball Brass Non-Spring Return Floating None 130 psi 896 kPa
VBN2AF3P0B 1/2 in. DN15 2.0 Cv 1.7 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating None 130 psi 896 kPa
VBN2AF3P0C 1/2 in. DN15 2.0 Cv 1.7 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac None 130 psi 896 kPa
VBN2AF3P0D 1/2 in. DN15 2.0 Cv 1.7 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating None 130 psi 896 kPa
VBN2AF3P0X 1/2 in. DN15 2.0 Cv 1.7 kvs Nickel-plated brass ball Brass No pre-assembled actuator None 130 psi 896 kPa

Combustion Controls
VBN2AF3S0A 1/2 in. DN15 2.0 Cv 1.7 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating None 130 psi 896 kPa
VBN2AF3S0B 1/2 in. DN15 2.0 Cv 1.7 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating None 130 psi 896 kPa

Residential
VBN2AF3S0C 1/2 in. DN15 2.0 Cv 1.7 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac None 130 psi 896 kPa
VBN2AF3S0D 1/2 in. DN15 2.0 Cv 1.7 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating None 130 psi 896 kPa
VBN2AF3S0X 1/2 in. DN15 2.0 Cv 1.7 kvs 316 stainless steel 316 Stainless Steel No pre-assembled actuator None 130 psi 896 kPa
VBN2AG3PRA 1/2 in. DN15 2.6 Cv 2.2 kvs Nickel-plated brass ball Brass Non-Spring Return Floating NEMA 3R 130 psi 896 kPa
VBN2AG3PRB 1/2 in. DN15 2.6 Cv 2.2 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating NEMA 3R 130 psi 896 kPa
VBN2AG3PRC 1/2 in. DN15 2.6 Cv 2.2 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac NEMA 3R 130 psi 896 kPa

Hydronic Controls
VBN2AG3PRD 1/2 in. DN15 2.6 Cv 2.2 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating NEMA 3R 130 psi 896 kPa
VBN2AG3SRA 1/2 in. DN15 2.6 Cv 2.2 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating NEMA 3R 130 psi 896 kPa
VBN2AG3SRB 1/2 in. DN15 2.6 Cv 2.2 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating NEMA 3R 130 psi 896 kPa
VBN2AG3SRC 1/2 in. DN15 2.6 Cv 2.2 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac NEMA 3R 130 psi 896 kPa
VBN2AG3SRD 1/2 in. DN15 2.6 Cv 2.2 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating NEMA 3R 130 psi 896 kPa
VBN2AG3P0A 1/2 in. DN15 2.6 Cv 2.2 kvs Nickel-plated brass ball Brass Non-Spring Return Floating None 130 psi 896 kPa
VBN2AG3P0B 1/2 in. DN15 2.6 Cv 2.2 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating None 130 psi 896 kPa
VBN2AG3P0C 1/2 in. DN15 2.6 Cv 2.2 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac None 130 psi 896 kPa
VBN2AG3P0D 1/2 in. DN15 2.6 Cv 2.2 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating None 130 psi 896 kPa

Controls
Water
VBN2AG3P0X 1/2 in. DN15 2.6 Cv 2.2 kvs Nickel-plated brass ball Brass No pre-assembled actuator None 130 psi 896 kPa
VBN2AG3S0A 1/2 in. DN15 2.6 Cv 2.2 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating None 130 psi 896 kPa
VBN2AG3S0B 1/2 in. DN15 2.6 Cv 2.2 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating None 130 psi 896 kPa
VBN2AG3S0C 1/2 in. DN15 2.6 Cv 2.2 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac None 130 psi 896 kPa
VBN2AG3S0D 1/2 in. DN15 2.6 Cv 2.2 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating None 130 psi 896 kPa
VBN2AG3S0X 1/2 in. DN15 2.6 Cv 2.2 kvs 316 stainless steel 316 Stainless Steel No pre-assembled actuator None 130 psi 896 kPa

Building Automation
VBN2AH3PRA 1/2 in. DN15 4.7 Cv 4.0 kvs Nickel-plated brass ball Brass Non-Spring Return Floating NEMA 3R 130 psi 896 kPa
VBN2AH3PRB 1/2 in. DN15 4.7 Cv 4.0 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating NEMA 3R 130 psi 896 kPa
VBN2AH3PRC 1/2 in. DN15 4.7 Cv 4.0 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac NEMA 3R 130 psi 896 kPa
VBN2AH3PRD 1/2 in. DN15 4.7 Cv 4.0 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating NEMA 3R 130 psi 896 kPa
VBN2AH3SRA 1/2 in. DN15 4.7 Cv 4.0 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating NEMA 3R 130 psi 896 kPa
VBN2AH3SRB 1/2 in. DN15 4.7 Cv 4.0 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating NEMA 3R 130 psi 896 kPa
VBN2AH3SRC 1/2 in. DN15 4.7 Cv 4.0 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac NEMA 3R 130 psi 896 kPa
VBN2AH3SRD 1/2 in. DN15 4.7 Cv 4.0 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating NEMA 3R 130 psi 896 kPa

Components
VBN2AH3P0A 1/2 in. DN15 4.7 Cv 4.0 kvs Nickel-plated brass ball Brass Non-Spring Return Floating None 130 psi 896 kPa

Commercial
VBN2AH3P0B 1/2 in. DN15 4.7 Cv 4.0 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating None 130 psi 896 kPa
VBN2AH3P0C 1/2 in. DN15 4.7 Cv 4.0 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac None 130 psi 896 kPa
VBN2AH3P0D 1/2 in. DN15 4.7 Cv 4.0 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating None 130 psi 896 kPa
VBN2AH3P0X 1/2 in. DN15 4.7 Cv 4.0 kvs Nickel-plated brass ball Brass No pre-assembled actuator None 130 psi 896 kPa
VBN2AH3S0A 1/2 in. DN15 4.7 Cv 4.0 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating None 130 psi 896 kPa
VBN2AH3S0B 1/2 in. DN15 4.7 Cv 4.0 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating None 130 psi 896 kPa
Pneumatic Controls

VBN2AH3S0C 1/2 in. DN15 4.7 Cv 4.0 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac None 130 psi 896 kPa
VBN2AH3S0D 1/2 in. DN15 4.7 Cv 4.0 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating None 130 psi 896 kPa
VBN2AH3S0X 1/2 in. DN15 4.7 Cv 4.0 kvs 316 stainless steel 316 Stainless Steel No pre-assembled actuator None 130 psi 896 kPa
VBN2AJ3PRA 1/2 in. DN15 8.0 Cv 6.9 kvs Nickel-plated brass ball Brass Non-Spring Return Floating NEMA 3R 130 psi 896 kPa
VBN2AJ3PRB 1/2 in. DN15 8.0 Cv 6.9 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating NEMA 3R 130 psi 896 kPa
VBN2AJ3PRC 1/2 in. DN15 8.0 Cv 6.9 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac NEMA 3R 130 psi 896 kPa
VBN2AJ3PRD 1/2 in. DN15 8.0 Cv 6.9 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating NEMA 3R 130 psi 896 kPa
Industrial Combustion

VBN2AJ3SRA 1/2 in. DN15 8.0 Cv 6.9 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating NEMA 3R 130 psi 896 kPa
VBN2AJ3SRB 1/2 in. DN15 8.0 Cv 6.9 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating NEMA 3R 130 psi 896 kPa
Controls

VBN2AJ3SRC 1/2 in. DN15 8.0 Cv 6.9 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac NEMA 3R 130 psi 896 kPa
VBN2AJ3SRD 1/2 in. DN15 8.0 Cv 6.9 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating NEMA 3R 130 psi 896 kPa

70-6910 577
Control Ball Valves
Maximum
Close-off
Weather
Valve Size Flow Capacity Materials Pressure
Enclo-
Product Number (inch) DN (Cv) (Kv) (Plug/Ball/Disc) (Stem) Actuation sure (psi) (kPa)
VBN2AJ3P0A 1/2 in. DN15 8.0 Cv 6.9 kvs Nickel-plated brass ball Brass Non-Spring Return Floating None 130 psi 896 kPa
VBN2AJ3P0B 1/2 in. DN15 8.0 Cv 6.9 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating None 130 psi 896 kPa
VBN2AJ3P0C 1/2 in. DN15 8.0 Cv 6.9 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac None 130 psi 896 kPa
VBN2AJ3P0D 1/2 in. DN15 8.0 Cv 6.9 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating None 130 psi 896 kPa
VBN2AJ3P0X 1/2 in. DN15 8.0 Cv 6.9 kvs Nickel-plated brass ball Brass No pre-assembled actuator None 130 psi 896 kPa
VBN2AJ3S0A 1/2 in. DN15 8.0 Cv 6.9 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating None 130 psi 896 kPa
VBN2AJ3S0B 1/2 in. DN15 8.0 Cv 6.9 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating None 130 psi 896 kPa
VBN2AJ3S0C 1/2 in. DN15 8.0 Cv 6.9 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac None 130 psi 896 kPa
VBN2AJ3S0D 1/2 in. DN15 8.0 Cv 6.9 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating None 130 psi 896 kPa
VBN2AJ3S0X 1/2 in. DN15 8.0 Cv 6.9 kvs 316 stainless steel 316 Stainless Steel No pre-assembled actuator None 130 psi 896 kPa
VBN2BB3PRA 3/4 in. DN20 0.31 Cv 0.27 kvs Nickel-plated brass ball Brass Non-Spring Return Floating NEMA 3R 130 psi 896 kPa
VBN2BB3PRB 3/4 in. DN20 0.31 Cv 0.27 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating NEMA 3R 130 psi 896 kPa
VBN2BB3PRC 3/4 in. DN20 0.31 Cv 0.27 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac NEMA 3R 130 psi 896 kPa
VBN2BB3PRD 3/4 in. DN20 0.31 Cv 0.27 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating NEMA 3R 130 psi 896 kPa
VBN2BB3SRA 3/4 in. DN20 0.31 Cv 0.27 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating NEMA 3R 130 psi 896 kPa
VBN2BB3SRB 3/4 in. DN20 0.31 Cv 0.27 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating NEMA 3R 130 psi 896 kPa
VBN2BB3SRC 3/4 in. DN20 0.31 Cv 0.27 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac NEMA 3R 130 psi 896 kPa
VBN2BB3SRD 3/4 in. DN20 0.31 Cv 0.27 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating NEMA 3R 130 psi 896 kPa
VBN2BB3P0A 3/4 in. DN20 0.31 Cv 0.27 kvs Nickel-plated brass ball Brass Non-Spring Return Floating None 130 psi 896 kPa
VBN2BB3P0B 3/4 in. DN20 0.31 Cv 0.27 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating None 130 psi 896 kPa
VBN2BB3P0C 3/4 in. DN20 0.31 Cv 0.27 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac None 130 psi 896 kPa
VBN2BB3P0D 3/4 in. DN20 0.31 Cv 0.27 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating None 130 psi 896 kPa
VBN2BB3P0X 3/4 in. DN20 0.31 Cv 0.27 kvs Nickel-plated brass ball Brass No pre-assembled actuator None 130 psi 896 kPa
VBN2BB3S0A 3/4 in. DN20 0.31 Cv 0.27 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating None 130 psi 896 kPa
VBN2BB3S0B 3/4 in. DN20 0.31 Cv 0.27 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating None 130 psi 896 kPa
VBN2BB3S0C 3/4 in. DN20 0.31 Cv 0.27 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac None 130 psi 896 kPa
VBN2BB3S0D 3/4 in. DN20 0.31 Cv 0.27 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating None 130 psi 896 kPa
VBN2BB3S0X 3/4 in. DN20 0.31 Cv 0.27 kvs 316 stainless steel 316 Stainless Steel No pre-assembled actuator None 130 psi 896 kPa
VBN2BD3PRA 3/4 in. DN20 0.63 Cv 0.54 kvs Nickel-plated brass ball Brass Non-Spring Return Floating NEMA 3R 130 psi 896 kPa
VBN2BD3PRB 3/4 in. DN20 0.63 Cv 0.54 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating NEMA 3R 130 psi 896 kPa
VBN2BD3PRC 3/4 in. DN20 0.63 Cv 0.54 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac NEMA 3R 130 psi 896 kPa
VBN2BD3PRD 3/4 in. DN20 0.63 Cv 0.54 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating NEMA 3R 130 psi 896 kPa
VBN2BD3SRA 3/4 in. DN20 0.63 Cv 0.54 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating NEMA 3R 130 psi 896 kPa
VBN2BD3SRB 3/4 in. DN20 0.63 Cv 0.54 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating NEMA 3R 130 psi 896 kPa
VBN2BD3SRC 3/4 in. DN20 0.63 Cv 0.54 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac NEMA 3R 130 psi 896 kPa
VBN2BD3SRD 3/4 in. DN20 0.63 Cv 0.54 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating NEMA 3R 130 psi 896 kPa
VBN2BD3P0A 3/4 in. DN20 0.63 Cv 0.54 kvs Nickel-plated brass ball Brass Non-Spring Return Floating None 130 psi 896 kPa
VBN2BD3P0B 3/4 in. DN20 0.63 Cv 0.54 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating None 130 psi 896 kPa
VBN2BD3P0C 3/4 in. DN20 0.63 Cv 0.54 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac None 130 psi 896 kPa
VBN2BD3P0D 3/4 in. DN20 0.63 Cv 0.54 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating None 130 psi 896 kPa
VBN2BD3P0X 3/4 in. DN20 0.63 Cv 0.54 kvs Nickel-plated brass ball Brass No pre-assembled actuator None 130 psi 896 kPa
VBN2BD3S0A 3/4 in. DN20 0.63 Cv 0.54 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating None 130 psi 896 kPa
VBN2BD3S0B 3/4 in. DN20 0.63 Cv 0.54 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating None 130 psi 896 kPa
VBN2BD3S0C 3/4 in. DN20 0.63 Cv 0.54 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac None 130 psi 896 kPa
VBN2BD3S0D 3/4 in. DN20 0.63 Cv 0.54 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating None 130 psi 896 kPa
VBN2BD3S0X 3/4 in. DN20 0.63 Cv 0.54 kvs 316 stainless steel 316 Stainless Steel No pre-assembled actuator None 130 psi 896 kPa
VBN2BE3PRA 3/4 in. DN20 1.2 Cv 1.0 kvs Nickel-plated brass ball Brass Non-Spring Return Floating NEMA 3R 130 psi 896 kPa
VBN2BE3PRB 3/4 in. DN20 1.2 Cv 1.0 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating NEMA 3R 130 psi 896 kPa
VBN2BE3PRC 3/4 in. DN20 1.2 Cv 1.0 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac NEMA 3R 130 psi 896 kPa
VBN2BE3PRD 3/4 in. DN20 1.2 Cv 1.0 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating NEMA 3R 130 psi 896 kPa
VBN2BE3SRA 3/4 in. DN20 1.2 Cv 1.0 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating NEMA 3R 130 psi 896 kPa
VBN2BE3SRB 3/4 in. DN20 1.2 Cv 1.0 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating NEMA 3R 130 psi 896 kPa
VBN2BE3SRC 3/4 in. DN20 1.2 Cv 1.0 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac NEMA 3R 130 psi 896 kPa
VBN2BE3SRD 3/4 in. DN20 1.2 Cv 1.0 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating NEMA 3R 130 psi 896 kPa
VBN2BE3P0A 3/4 in. DN20 1.2 Cv 1.0 kvs Nickel-plated brass ball Brass Non-Spring Return Floating None 130 psi 896 kPa
VBN2BE3P0B 3/4 in. DN20 1.2 Cv 1.0 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating None 130 psi 896 kPa
VBN2BE3P0C 3/4 in. DN20 1.2 Cv 1.0 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac None 130 psi 896 kPa
VBN2BE3P0D 3/4 in. DN20 1.2 Cv 1.0 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating None 130 psi 896 kPa
VBN2BE3P0X 3/4 in. DN20 1.2 Cv 1.0 kvs Nickel-plated brass ball Brass No pre-assembled actuator None 130 psi 896 kPa

578 customer.honeywell.com 70-6910


Control Ball Valves

Controls
Maximum

Home
Close-off
Weather
Valve Size Flow Capacity Materials Pressure
Enclo-
Product Number (inch) DN (Cv) (Kv) (Plug/Ball/Disc) (Stem) Actuation sure (psi) (kPa)
VBN2BE3S0A 3/4 in. DN20 1.2 Cv 1.0 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating None 130 psi 896 kPa
VBN2BE3S0B 3/4 in. DN20 1.2 Cv 1.0 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating None 130 psi 896 kPa
VBN2BE3S0C 3/4 in. DN20 1.2 Cv 1.0 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac None 130 psi 896 kPa

Indoor Air Quality


VBN2BE3S0D 3/4 in. DN20 1.2 Cv 1.0 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating None 130 psi 896 kPa
VBN2BE3S0X 3/4 in. DN20 1.2 Cv 1.0 kvs 316 stainless steel 316 Stainless Steel No pre-assembled actuator None 130 psi 896 kPa
VBN2BG3PRA 3/4 in. DN20 2.6 Cv 2.2 kvs Nickel-plated brass ball Brass Non-Spring Return Floating NEMA 3R 130 psi 896 kPa
VBN2BG3PRB 3/4 in. DN20 2.6 Cv 2.2 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating NEMA 3R 130 psi 896 kPa
VBN2BG3PRC 3/4 in. DN20 2.6 Cv 2.2 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac NEMA 3R 130 psi 896 kPa
VBN2BG3PRD 3/4 in. DN20 2.6 Cv 2.2 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating NEMA 3R 130 psi 896 kPa
VBN2BG3SRA 3/4 in. DN20 2.6 Cv 2.2 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating NEMA 3R 130 psi 896 kPa

Combustion Controls
VBN2BG3SRB 3/4 in. DN20 2.6 Cv 2.2 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating NEMA 3R 130 psi 896 kPa
VBN2BG3SRC 3/4 in. DN20 2.6 Cv 2.2 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac NEMA 3R 130 psi 896 kPa

Residential
VBN2BG3SRD 3/4 in. DN20 2.6 Cv 2.2 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating NEMA 3R 130 psi 896 kPa
VBN2BG3P0A 3/4 in. DN20 2.6 Cv 2.2 kvs Nickel-plated brass ball Brass Non-Spring Return Floating None 130 psi 896 kPa
VBN2BG3P0B 3/4 in. DN20 2.6 Cv 2.2 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating None 130 psi 896 kPa
VBN2BG3P0C 3/4 in. DN20 2.6 Cv 2.2 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac None 130 psi 896 kPa
VBN2BG3P0D 3/4 in. DN20 2.6 Cv 2.2 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating None 130 psi 896 kPa
VBN2BG3P0X 3/4 in. DN20 2.6 Cv 2.2 kvs Nickel-plated brass ball Brass No pre-assembled actuator None 130 psi 896 kPa

Hydronic Controls
VBN2BG3S0A 3/4 in. DN20 2.6 Cv 2.2 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating None 130 psi 896 kPa
VBN2BG3S0B 3/4 in. DN20 2.6 Cv 2.2 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating None 130 psi 896 kPa
VBN2BG3S0C 3/4 in. DN20 2.6 Cv 2.2 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac None 130 psi 896 kPa
VBN2BG3S0D 3/4 in. DN20 2.6 Cv 2.2 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating None 130 psi 896 kPa
VBN2BG3S0X 3/4 in. DN20 2.6 Cv 2.2 kvs 316 stainless steel 316 Stainless Steel No pre-assembled actuator None 130 psi 896 kPa
VBN2BH3PRA 3/4 in. DN20 4.3 Cv 3.7 kvs Nickel-plated brass ball Brass Non-Spring Return Floating NEMA 3R 130 psi 896 kPa
VBN2BH3PRB 3/4 in. DN20 4.3 Cv 3.7 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating NEMA 3R 130 psi 896 kPa
VBN2BH3PRC 3/4 in. DN20 4.3 Cv 3.7 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac NEMA 3R 130 psi 896 kPa
VBN2BH3PRD 3/4 in. DN20 4.3 Cv 3.7 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating NEMA 3R 130 psi 896 kPa

Controls
Water
VBN2BH3SRA 3/4 in. DN20 4.3 Cv 3.7 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating NEMA 3R 130 psi 896 kPa
VBN2BH3SRB 3/4 in. DN20 4.3 Cv 3.7 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating NEMA 3R 130 psi 896 kPa
VBN2BH3SRC 3/4 in. DN20 4.3 Cv 3.7 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac NEMA 3R 130 psi 896 kPa
VBN2BH3SRD 3/4 in. DN20 4.3 Cv 3.7 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating NEMA 3R 130 psi 896 kPa
VBN2BH3P0A 3/4 in. DN20 4.3 Cv 3.7 kvs Nickel-plated brass ball Brass Non-Spring Return Floating None 130 psi 896 kPa
VBN2BH3P0B 3/4 in. DN20 4.3 Cv 3.7 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating None 130 psi 896 kPa

Building Automation
VBN2BH3P0C 3/4 in. DN20 4.3 Cv 3.7 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac None 130 psi 896 kPa
VBN2BH3P0D 3/4 in. DN20 4.3 Cv 3.7 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating None 130 psi 896 kPa
VBN2BH3P0X 3/4 in. DN20 4.3 Cv 3.7 kvs Nickel-plated brass ball Brass No pre-assembled actuator None 130 psi 896 kPa
VBN2BH3S0A 3/4 in. DN20 4.3 Cv 3.7 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating None 130 psi 896 kPa
VBN2BH3S0B 3/4 in. DN20 4.3 Cv 3.7 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating None 130 psi 896 kPa
VBN2BH3S0C 3/4 in. DN20 4.3 Cv 3.7 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac None 130 psi 896 kPa
VBN2BH3S0D 3/4 in. DN20 4.3 Cv 3.7 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating None 130 psi 896 kPa
VBN2BH3S0X 3/4 in. DN20 4.3 Cv 3.7 kvs 316 stainless steel 316 Stainless Steel No pre-assembled actuator None 130 psi 896 kPa

Components
VBN2BJ3PRA 3/4 in. DN20 7.4 Cv 6.4 kvs Nickel-plated brass ball Brass Non-Spring Return Floating NEMA 3R 130 psi 896 kPa

Commercial
VBN2BJ3PRB 3/4 in. DN20 7.4 Cv 6.4 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating NEMA 3R 130 psi 896 kPa
VBN2BJ3PRC 3/4 in. DN20 7.4 Cv 6.4 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac NEMA 3R 130 psi 896 kPa
VBN2BJ3PRD 3/4 in. DN20 7.4 Cv 6.4 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating NEMA 3R 130 psi 896 kPa
VBN2BJ3SRA 3/4 in. DN20 7.4 Cv 6.4 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating NEMA 3R 130 psi 896 kPa
VBN2BJ3SRB 3/4 in. DN20 7.4 Cv 6.4 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating NEMA 3R 130 psi 896 kPa
VBN2BJ3SRC 3/4 in. DN20 7.4 Cv 6.4 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac NEMA 3R 130 psi 896 kPa
Pneumatic Controls

VBN2BJ3SRD 3/4 in. DN20 7.4 Cv 6.4 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating NEMA 3R 130 psi 896 kPa
VBN2BJ3P0A 3/4 in. DN20 7.4 Cv 6.4 kvs Nickel-plated brass ball Brass Non-Spring Return Floating None 130 psi 896 kPa
VBN2BJ3P0B 3/4 in. DN20 7.4 Cv 6.4 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating None 130 psi 896 kPa
VBN2BJ3P0C 3/4 in. DN20 7.4 Cv 6.4 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac None 130 psi 896 kPa
VBN2BJ3P0D 3/4 in. DN20 7.4 Cv 6.4 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating None 130 psi 896 kPa
VBN2BJ3P0X 3/4 in. DN20 7.4 Cv 6.4 kvs Nickel-plated brass ball Brass No pre-assembled actuator None 130 psi 896 kPa
VBN2BJ3S0A 3/4 in. DN20 7.4 Cv 6.4 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating None 130 psi 896 kPa
Industrial Combustion

VBN2BJ3S0B 3/4 in. DN20 7.4 Cv 6.4 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating None 130 psi 896 kPa
VBN2BJ3S0C 3/4 in. DN20 7.4 Cv 6.4 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac None 130 psi 896 kPa
Controls

VBN2BJ3S0D 3/4 in. DN20 7.4 Cv 6.4 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating None 130 psi 896 kPa
VBN2BJ3S0X 3/4 in. DN20 7.4 Cv 6.4 kvs 316 stainless steel 316 Stainless Steel No pre-assembled actuator None 130 psi 896 kPa

70-6910 579
Control Ball Valves
Maximum
Close-off
Weather
Valve Size Flow Capacity Materials Pressure
Enclo-
Product Number (inch) DN (Cv) (Kv) (Plug/Ball/Disc) (Stem) Actuation sure (psi) (kPa)
VBN2BK3PRA 3/4 in. DN20 10.1 Cv 8.7 kvs Nickel-plated brass ball Brass Non-Spring Return Floating NEMA 3R 130 psi 896 kPa
VBN2BK3PRB 3/4 in. DN20 10.1 Cv 8.7 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating NEMA 3R 130 psi 896 kPa
VBN2BK3PRC 3/4 in. DN20 10.1 Cv 8.7 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac NEMA 3R 130 psi 896 kPa
VBN2BK3PRD 3/4 in. DN20 10.1 Cv 8.7 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating NEMA 3R 130 psi 896 kPa
VBN2BK3SRA 3/4 in. DN20 10.1 Cv 8.7 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating NEMA 3R 130 psi 896 kPa
VBN2BK3SRB 3/4 in. DN20 10.1 Cv 8.7 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating NEMA 3R 130 psi 896 kPa
VBN2BK3SRC 3/4 in. DN20 10.1 Cv 8.7 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac NEMA 3R 130 psi 896 kPa
VBN2BK3SRD 3/4 in. DN20 10.1 Cv 8.7 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating NEMA 3R 130 psi 896 kPa
VBN2BK3P0A 3/4 in. DN20 10.1 Cv 8.7 kvs Nickel-plated brass ball Brass Non-Spring Return Floating None 130 psi 896 kPa
VBN2BK3P0B 3/4 in. DN20 10.1 Cv 8.7 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating None 130 psi 896 kPa
VBN2BK3P0C 3/4 in. DN20 10.1 Cv 8.7 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac None 130 psi 896 kPa
VBN2BK3P0D 3/4 in. DN20 10.1 Cv 8.7 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating None 130 psi 896 kPa
VBN2BK3P0X 3/4 in. DN20 10.1 Cv 8.7 kvs Nickel-plated brass ball Brass No pre-assembled actuator None 130 psi 896 kPa
VBN2BK3S0A 3/4 in. DN20 10.1 Cv 8.7 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating None 130 psi 896 kPa
VBN2BK3S0B 3/4 in. DN20 10.1 Cv 8.7 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating None 130 psi 896 kPa
VBN2BK3S0C 3/4 in. DN20 10.1 Cv 8.7 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac None 130 psi 896 kPa
VBN2BK3S0D 3/4 in. DN20 10.1 Cv 8.7 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating None 130 psi 896 kPa
VBN2BK3S0X 3/4 in. DN20 10.1 Cv 8.7 kvs 316 stainless steel 316 Stainless Steel No pre-assembled actuator None 130 psi 896 kPa
VBN2CH3PRA 1 in. DN25 4.4 Cv 3.8 kvs Nickel-plated brass ball Brass Non-Spring Return Floating NEMA 3R 100 psi 689 kPa
VBN2CH3PRB 1 in. DN25 4.4 Cv 3.8 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa
VBN2CH3PRC 1 in. DN25 4.4 Cv 3.8 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa
VBN2CH3PRD 1 in. DN25 4.4 Cv 3.8 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa
VBN2CH3SRA 1 in. DN25 4.4 Cv 3.8 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating NEMA 3R 100 psi 689 kPa
VBN2CH3SRB 1 in. DN25 4.4 Cv 3.8 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa
VBN2CH3SRC 1 in. DN25 4.4 Cv 3.8 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa
VBN2CH3SRD 1 in. DN25 4.4 Cv 3.8 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa
VBN2CH3P0A 1 in. DN25 4.4 Cv 3.8 kvs Nickel-plated brass ball Brass Non-Spring Return Floating None 100 psi 689 kPa
VBN2CH3P0B 1 in. DN25 4.4 Cv 3.8 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating None 100 psi 689 kPa
VBN2CH3P0C 1 in. DN25 4.4 Cv 3.8 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac None 100 psi 689 kPa
VBN2CH3P0D 1 in. DN25 4.4 Cv 3.8 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating None 100 psi 689 kPa
VBN2CH3P0X 1 in. DN25 4.4 Cv 3.8 kvs Nickel-plated brass ball Brass No pre-assembled actuator None 100 psi 689 kPa
VBN2CH3S0A 1 in. DN25 4.4 Cv 3.8 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating None 100 psi 689 kPa
VBN2CH3S0B 1 in. DN25 4.4 Cv 3.8 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating None 100 psi 689 kPa
VBN2CH3S0C 1 in. DN25 4.4 Cv 3.8 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac None 100 psi 689 kPa
VBN2CH3S0D 1 in. DN25 4.4 Cv 3.8 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating None 100 psi 689 kPa
VBN2CH3S0X 1 in. DN25 4.4 Cv 3.8 kvs 316 stainless steel 316 Stainless Steel No pre-assembled actuator None 100 psi 689 kPa
VBN2CJ3PRA 1 in. DN25 9.0 Cv 7.7 kvs Nickel-plated brass ball Brass Non-Spring Return Floating NEMA 3R 100 psi 689 kPa
VBN2CJ3PRB 1 in. DN25 9.0 Cv 7.7 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa
VBN2CJ3PRC 1 in. DN25 9.0 Cv 7.7 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa
VBN2CJ3PRD 1 in. DN25 9.0 Cv 7.7 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa
VBN2CJ3SRA 1 in. DN25 9.0 Cv 7.7 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating NEMA 3R 100 psi 689 kPa
VBN2CJ3SRB 1 in. DN25 9.0 Cv 7.7 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa
VBN2CJ3SRC 1 in. DN25 9.0 Cv 7.7 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa
VBN2CJ3SRD 1 in. DN25 9.0 Cv 7.7 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa
VBN2CJ3P0A 1 in. DN25 9.0 Cv 7.7 kvs Nickel-plated brass ball Brass Non-Spring Return Floating None 100 psi 689 kPa
VBN2CJ3P0B 1 in. DN25 9.0 Cv 7.7 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating None 100 psi 689 kPa
VBN2CJ3P0C 1 in. DN25 9.0 Cv 7.7 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac None 100 psi 689 kPa
VBN2CJ3P0D 1 in. DN25 9.0 Cv 7.7 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating None 100 psi 689 kPa
VBN2CJ3P0X 1 in. DN25 9.0 Cv 7.7 kvs Nickel-plated brass ball Brass No pre-assembled actuator None 100 psi 689 kPa
VBN2CJ3S0A 1 in. DN25 9.0 Cv 7.7 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating None 100 psi 689 kPa
VBN2CJ3S0B 1 in. DN25 9.0 Cv 7.7 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating None 100 psi 689 kPa
VBN2CJ3S0C 1 in. DN25 9.0 Cv 7.7 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac None 100 psi 689 kPa
VBN2CJ3S0D 1 in. DN25 9.0 Cv 7.7 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating None 100 psi 689 kPa
VBN2CJ3S0X 1 in. DN25 9.0 Cv 7.7 kvs 316 stainless steel 316 Stainless Steel No pre-assembled actuator None 100 psi 689 kPa
VBN2CL3PRA 1 in. DN25 15.3 Cv 13.2 kvs Nickel-plated brass ball Brass Non-Spring Return Floating NEMA 3R 100 psi 689 kPa
VBN2CL3PRB 1 in. DN25 15.3 Cv 13.2 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa
VBN2CL3PRC 1 in. DN25 15.3 Cv 13.2 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa
VBN2CL3PRD 1 in. DN25 15.3 Cv 13.2 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa
VBN2CL3SRA 1 in. DN25 15.3 Cv 13.2 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating NEMA 3R 100 psi 689 kPa

580 customer.honeywell.com 70-6910


Control Ball Valves

Controls
Maximum

Home
Close-off
Weather
Valve Size Flow Capacity Materials Pressure
Enclo-
Product Number (inch) DN (Cv) (Kv) (Plug/Ball/Disc) (Stem) Actuation sure (psi) (kPa)
VBN2CL3SRB 1 in. DN25 15.3 Cv 13.2 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa
VBN2CL3SRC 1 in. DN25 15.3 Cv 13.2 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa
VBN2CL3SRD 1 in. DN25 15.3 Cv 13.2 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa

Indoor Air Quality


VBN2CL3P0A 1 in. DN25 15.3 Cv 13.2 kvs Nickel-plated brass ball Brass Non-Spring Return Floating None 100 psi 689 kPa
VBN2CL3P0B 1 in. DN25 15.3 Cv 13.2 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating None 100 psi 689 kPa
VBN2CL3P0C 1 in. DN25 15.3 Cv 13.2 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac None 100 psi 689 kPa
VBN2CL3P0D 1 in. DN25 15.3 Cv 13.2 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating None 100 psi 689 kPa
VBN2CL3P0X 1 in. DN25 15.3 Cv 13.2 kvs Nickel-plated brass ball Brass No pre-assembled actuator None 100 psi 689 kPa
VBN2CL3S0A 1 in. DN25 15.3 Cv 13.2 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating None 100 psi 689 kPa
VBN2CL3S0B 1 in. DN25 15.3 Cv 13.2 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating None 100 psi 689 kPa

Combustion Controls
VBN2CL3S0C 1 in. DN25 15.3 Cv 13.2 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac None 100 psi 689 kPa
VBN2CL3S0D 1 in. DN25 15.3 Cv 13.2 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating None 100 psi 689 kPa

Residential
VBN2CL3S0X 1 in. DN25 15.3 Cv 13.2 kvs 316 stainless steel 316 Stainless Steel No pre-assembled actuator None 100 psi 689 kPa
VBN2CM3PRA 1 in. DN25 26 Cv 22 kvs Nickel-plated brass ball Brass Non-Spring Return Floating NEMA 3R 100 psi 689 kPa
VBN2CM3PRB 1 in. DN25 26 Cv 22 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa
VBN2CM3PRC 1 in. DN25 26 Cv 22 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa
VBN2CM3PRD 1 in. DN25 26 Cv 22 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa
VBN2CM3SRA 1 in. DN25 26 Cv 22 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating NEMA 3R 100 psi 689 kPa

Hydronic Controls
VBN2CM3SRB 1 in. DN25 26 Cv 22 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa
VBN2CM3SRC 1 in. DN25 26 Cv 22 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa
VBN2CM3SRD 1 in. DN25 26 Cv 22 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa
VBN2CM3P0A 1 in. DN25 26 Cv 22 kvs Nickel-plated brass ball Brass Non-Spring Return Floating None 100 psi 689 kPa
VBN2CM3P0B 1 in. DN25 26 Cv 22 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating None 100 psi 689 kPa
VBN2CM3P0C 1 in. DN25 26 Cv 22 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac None 100 psi 689 kPa
VBN2CM3P0D 1 in. DN25 26 Cv 22 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating None 100 psi 689 kPa
VBN2CM3P0X 1 in. DN25 26 Cv 22 kvs Nickel-plated brass ball Brass No pre-assembled actuator None 100 psi 689 kPa
VBN2CM3S0A 1 in. DN25 26 Cv 22 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating None 100 psi 689 kPa

Controls
Water
VBN2CM3S0B 1 in. DN25 26 Cv 22 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating None 100 psi 689 kPa
VBN2CM3S0C 1 in. DN25 26 Cv 22 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac None 100 psi 689 kPa
VBN2CM3S0D 1 in. DN25 26 Cv 22 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating None 100 psi 689 kPa
VBN2CM3S0X 1 in. DN25 26 Cv 22 kvs 316 stainless steel 316 Stainless Steel No pre-assembled actuator None 100 psi 689 kPa
VBN2DH3PRA 1 1/4 in. DN32 4.4 Cv 3.8 kvs Nickel-plated brass ball Brass Non-Spring Return Floating NEMA 3R 100 psi 689 kPa
VBN2DH3PRB 1 1/4 in. DN32 4.4 Cv 3.8 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa

Building Automation
VBN2DH3PRC 1 1/4 in. DN32 4.4 Cv 3.8 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa
VBN2DH3PRD 1 1/4 in. DN32 4.4 Cv 3.8 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa
VBN2DH3SRA 1 1/4 in. DN32 4.4 Cv 3.8 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating NEMA 3R 100 psi 689 kPa
VBN2DH3SRB 1 1/4 in. DN32 4.4 Cv 3.8 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa
VBN2DH3SRC 1 1/4 in. DN32 4.4 Cv 3.8 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa
VBN2DH3SRD 1 1/4 in. DN32 4.4 Cv 3.8 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa
VBN2DH3P0A 1 1/4 in. DN32 4.4 Cv 3.8 kvs Nickel-plated brass ball Brass Non-Spring Return Floating None 100 psi 689 kPa
VBN2DH3P0B 1 1/4 in. DN32 4.4 Cv 3.8 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating None 100 psi 689 kPa

Components
VBN2DH3P0C 1 1/4 in. DN32 4.4 Cv 3.8 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac None 100 psi 689 kPa

Commercial
VBN2DH3P0D 1 1/4 in. DN32 4.4 Cv 3.8 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating None 100 psi 689 kPa
VBN2DH3P0X 1 1/4 in. DN32 4.4 Cv 3.8 kvs Nickel-plated brass ball Brass No pre-assembled actuator None 100 psi 689 kPa
VBN2DH3S0A 1 1/4 in. DN32 4.4 Cv 3.8 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating None 100 psi 689 kPa
VBN2DH3S0B 1 1/4 in. DN32 4.4 Cv 3.8 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating None 100 psi 689 kPa
VBN2DH3S0C 1 1/4 in. DN32 4.4 Cv 3.8 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac None 100 psi 689 kPa
VBN2DH3S0D 1 1/4 in. DN32 4.4 Cv 3.8 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating None 100 psi 689 kPa
Pneumatic Controls

VBN2DH3S0X 1 1/4 in. DN32 4.4 Cv 3.8 kvs 316 stainless steel 316 Stainless Steel No pre-assembled actuator None 100 psi 689 kPa
VBN2DJ3PRA 1 1/4 in. DN32 8.3 Cv 7.1 kvs Nickel-plated brass ball Brass Non-Spring Return Floating NEMA 3R 100 psi 689 kPa
VBN2DJ3PRB 1 1/4 in. DN32 8.3 Cv 7.1 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa
VBN2DJ3PRC 1 1/4 in. DN32 8.3 Cv 7.1 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa
VBN2DJ3PRD 1 1/4 in. DN32 8.3 Cv 7.1 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa
VBN2DJ3SRA 1 1/4 in. DN32 8.3 Cv 7.1 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating NEMA 3R 100 psi 689 kPa
VBN2DJ3SRB 1 1/4 in. DN32 8.3 Cv 7.1 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa
Industrial Combustion

VBN2DJ3SRC 1 1/4 in. DN32 8.3 Cv 7.1 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa
VBN2DJ3SRD 1 1/4 in. DN32 8.3 Cv 7.1 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa
Controls

VBN2DJ3P0A 1 1/4 in. DN32 8.3 Cv 7.1 kvs Nickel-plated brass ball Brass Non-Spring Return Floating None 100 psi 689 kPa
VBN2DJ3P0B 1 1/4 in. DN32 8.3 Cv 7.1 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating None 100 psi 689 kPa

70-6910 581
Control Ball Valves
Maximum
Close-off
Weather
Valve Size Flow Capacity Materials Pressure
Enclo-
Product Number (inch) DN (Cv) (Kv) (Plug/Ball/Disc) (Stem) Actuation sure (psi) (kPa)
VBN2DJ3P0C 1 1/4 in. DN32 8.3 Cv 7.1 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac None 100 psi 689 kPa
VBN2DJ3P0D 1 1/4 in. DN32 8.3 Cv 7.1 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating None 100 psi 689 kPa
VBN2DJ3P0X 1 1/4 in. DN32 8.3 Cv 7.1 kvs Nickel-plated brass ball Brass No pre-assembled actuator None 100 psi 689 kPa
VBN2DJ3S0A 1 1/4 in. DN32 8.3 Cv 7.1 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating None 100 psi 689 kPa
VBN2DJ3S0B 1 1/4 in. DN32 8.3 Cv 7.1 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating None 100 psi 689 kPa
VBN2DJ3S0C 1 1/4 in. DN32 8.3 Cv 7.1 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac None 100 psi 689 kPa
VBN2DJ3S0D 1 1/4 in. DN32 8.3 Cv 7.1 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating None 100 psi 689 kPa
VBN2DJ3S0X 1 1/4 in. DN32 8.3 Cv 7.1 kvs 316 stainless steel 316 Stainless Steel No pre-assembled actuator None 100 psi 689 kPa
VBN2DK3PRA 1 1/4 in. DN32 14.9 Cv 12.8 kvs Nickel-plated brass ball Brass Non-Spring Return Floating NEMA 3R 100 psi 689 kPa
VBN2DK3PRB 1 1/4 in. DN32 14.9 Cv 12.8 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa
VBN2DK3PRC 1 1/4 in. DN32 14.9 Cv 12.8 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa
VBN2DK3PRD 1 1/4 in. DN32 14.9 Cv 12.8 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa
VBN2DK3SRA 1 1/4 in. DN32 14.9 Cv 12.8 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating NEMA 3R 100 psi 689 kPa
VBN2DK3SRB 1 1/4 in. DN32 14.9 Cv 12.8 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa
VBN2DK3SRC 1 1/4 in. DN32 14.9 Cv 12.8 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa
VBN2DK3SRD 1 1/4 in. DN32 14.9 Cv 12.8 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa
VBN2DK3P0A 1 1/4 in. DN32 14.9 Cv 12.8 kvs Nickel-plated brass ball Brass Non-Spring Return Floating None 100 psi 689 kPa
VBN2DK3P0B 1 1/4 in. DN32 14.9 Cv 12.8 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating None 100 psi 689 kPa
VBN2DK3P0C 1 1/4 in. DN32 14.9 Cv 12.8 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac None 100 psi 689 kPa
VBN2DK3P0D 1 1/4 in. DN32 14.9 Cv 12.8 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating None 100 psi 689 kPa
VBN2DK3P0X 1 1/4 in. DN32 14.9 Cv 12.8 kvs Nickel-plated brass ball Brass No pre-assembled actuator None 100 psi 689 kPa
VBN2DK3S0A 1 1/4 in. DN32 14.9 Cv 12.8 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating None 100 psi 689 kPa
VBN2DK3S0B 1 1/4 in. DN32 14.9 Cv 12.8 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating None 100 psi 689 kPa
VBN2DK3S0C 1 1/4 in. DN32 14.9 Cv 12.8 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac None 100 psi 689 kPa
VBN2DK3S0D 1 1/4 in. DN32 14.9 Cv 12.8 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating None 100 psi 689 kPa
VBN2DK3S0X 1 1/4 in. DN32 14.9 Cv 12.8 kvs 316 stainless steel 316 Stainless Steel No pre-assembled actuator None 100 psi 689 kPa
VBN2DL3PRA 1 1/4 in. DN32 25 Cv 22 kvs Nickel-plated brass ball Brass Non-Spring Return Floating NEMA 3R 100 psi 689 kPa
VBN2DL3PRB 1 1/4 in. DN32 25 Cv 22 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa
VBN2DL3PRC 1 1/4 in. DN32 25 Cv 22 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa
VBN2DL3PRD 1 1/4 in. DN32 25 Cv 22 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa
VBN2DL3SRA 1 1/4 in. DN32 25 Cv 22 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating NEMA 3R 100 psi 689 kPa
VBN2DL3SRB 1 1/4 in. DN32 25 Cv 22 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa
VBN2DL3SRC 1 1/4 in. DN32 25 Cv 22 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa
VBN2DL3SRD 1 1/4 in. DN32 25 Cv 22 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa
VBN2DL3P0A 1 1/4 in. DN32 25 Cv 22 kvs Nickel-plated brass ball Brass Non-Spring Return Floating None 100 psi 689 kPa
VBN2DL3P0B 1 1/4 in. DN32 25 Cv 22 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating None 100 psi 689 kPa
VBN2DL3P0C 1 1/4 in. DN32 25 Cv 22 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac None 100 psi 689 kPa
VBN2DL3P0D 1 1/4 in. DN32 25 Cv 22 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating None 100 psi 689 kPa
VBN2DL3P0X 1 1/4 in. DN32 25 Cv 22 kvs Nickel-plated brass ball Brass No pre-assembled actuator None 100 psi 689 kPa
VBN2DL3S0A 1 1/4 in. DN32 25 Cv 22 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating None 100 psi 689 kPa
VBN2DL3S0B 1 1/4 in. DN32 25 Cv 22 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating None 100 psi 689 kPa
VBN2DL3S0C 1 1/4 in. DN32 25 Cv 22 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac None 100 psi 689 kPa
VBN2DL3S0D 1 1/4 in. DN32 25 Cv 22 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating None 100 psi 689 kPa
VBN2DL3S0X 1 1/4 in. DN32 25 Cv 22 kvs 316 stainless steel 316 Stainless Steel No pre-assembled actuator None 100 psi 689 kPa
VBN2DM3PRA 1 1/4 in. DN32 37 Cv 32 kvs Nickel-plated brass ball Brass Non-Spring Return Floating NEMA 3R 100 psi 689 kPa
VBN2DM3PRB 1 1/4 in. DN32 37 Cv 32 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa
VBN2DM3PRC 1 1/4 in. DN32 37 Cv 32 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa
VBN2DM3PRD 1 1/4 in. DN32 37 Cv 32 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa
VBN2DM3SRA 1 1/4 in. DN32 37 Cv 32 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating NEMA 3R 100 psi 689 kPa
VBN2DM3SRB 1 1/4 in. DN32 37 Cv 32 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa
VBN2DM3SRC 1 1/4 in. DN32 37 Cv 32 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa
VBN2DM3SRD 1 1/4 in. DN32 37 Cv 32 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa
VBN2DM3P0A 1 1/4 in. DN32 37 Cv 32 kvs Nickel-plated brass ball Brass Non-Spring Return Floating None 100 psi 689 kPa
VBN2DM3P0B 1 1/4 in. DN32 37 Cv 32 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating None 100 psi 689 kPa
VBN2DM3P0C 1 1/4 in. DN32 37 Cv 32 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac None 100 psi 689 kPa
VBN2DM3P0D 1 1/4 in. DN32 37 Cv 32 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating None 100 psi 689 kPa
VBN2DM3P0X 1 1/4 in. DN32 37 Cv 32 kvs Nickel-plated brass ball Brass No pre-assembled actuator None 100 psi 689 kPa
VBN2DM3S0A 1 1/4 in. DN32 37 Cv 32 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating None 100 psi 689 kPa
VBN2DM3S0B 1 1/4 in. DN32 37 Cv 32 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating None 100 psi 689 kPa

582 customer.honeywell.com 70-6910


Control Ball Valves

Controls
Maximum

Home
Close-off
Weather
Valve Size Flow Capacity Materials Pressure
Enclo-
Product Number (inch) DN (Cv) (Kv) (Plug/Ball/Disc) (Stem) Actuation sure (psi) (kPa)
VBN2DM3S0C 1 1/4 in. DN32 37 Cv 32 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac None 100 psi 689 kPa
VBN2DM3S0D 1 1/4 in. DN32 37 Cv 32 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating None 100 psi 689 kPa
VBN2DM3S0X 1 1/4 in. DN32 37 Cv 32 kvs 316 stainless steel 316 Stainless Steel No pre-assembled actuator None 100 psi 689 kPa

Indoor Air Quality


VBN2DN3PRA 1 1/4 in. DN32 41 Cv 35 kvs Nickel-plated brass ball Brass Non-Spring Return Floating NEMA 3R 100 psi 689 kPa
VBN2DN3PRB 1 1/4 in. DN32 41 Cv 35 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa
VBN2DN3PRC 1 1/4 in. DN32 41 Cv 35 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa
VBN2DN3PRD 1 1/4 in. DN32 41 Cv 35 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa
VBN2DN3SRA 1 1/4 in. DN32 41 Cv 35 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating NEMA 3R 100 psi 689 kPa
VBN2DN3SRB 1 1/4 in. DN32 41 Cv 35 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa
VBN2DN3SRC 1 1/4 in. DN32 41 Cv 35 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa

Combustion Controls
VBN2DN3SRD 1 1/4 in. DN32 41 Cv 35 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa
VBN2DN3P0A 1 1/4 in. DN32 41 Cv 35 kvs Nickel-plated brass ball Brass Non-Spring Return Floating None 100 psi 689 kPa

Residential
VBN2DN3P0B 1 1/4 in. DN32 41 Cv 35 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating None 100 psi 689 kPa
VBN2DN3P0C 1 1/4 in. DN32 41 Cv 35 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac None 100 psi 689 kPa
VBN2DN3P0D 1 1/4 in. DN32 41 Cv 35 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating None 100 psi 689 kPa
VBN2DN3P0X 1 1/4 in. DN32 41 Cv 35 kvs Nickel-plated brass ball Brass No pre-assembled actuator None 100 psi 689 kPa
VBN2DN3S0A 1 1/4 in. DN32 41 Cv 35 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating None 100 psi 689 kPa
VBN2DN3S0B 1 1/4 in. DN32 41 Cv 35 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating None 100 psi 689 kPa

Hydronic Controls
VBN2DN3S0C 1 1/4 in. DN32 41 Cv 35 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac None 100 psi 689 kPa
VBN2DN3S0D 1 1/4 in. DN32 41 Cv 35 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating None 100 psi 689 kPa
VBN2DN3S0X 1 1/4 in. DN32 41 Cv 35 kvs 316 stainless steel 316 Stainless Steel No pre-assembled actuator None 100 psi 689 kPa
VBN2EL3PRA 1 1/2 in. DN40 23 Cv 19.8 kvs Nickel-plated brass ball Brass Non-Spring Return Floating NEMA 3R 100 psi 689 kPa
VBN2EL3PRB 1 1/2 in. DN40 23 Cv 19.8 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa
VBN2EL3PRC 1 1/2 in. DN40 23 Cv 19.8 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa
VBN2EL3PRD 1 1/2 in. DN40 23 Cv 19.8 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa
VBN2EL3SRA 1 1/2 in. DN40 23 Cv 19.8 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating NEMA 3R 100 psi 689 kPa
VBN2EL3SRB 1 1/2 in. DN40 23 Cv 19.8 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa

Controls
Water
VBN2EL3SRC 1 1/2 in. DN40 23 Cv 19.8 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa
VBN2EL3SRD 1 1/2 in. DN40 23 Cv 19.8 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa
VBN2EL3P0A 1 1/2 in. DN40 23 Cv 19.8 kvs Nickel-plated brass ball Brass Non-Spring Return Floating None 100 psi 689 kPa
VBN2EL3P0B 1 1/2 in. DN40 23 Cv 19.8 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating None 100 psi 689 kPa
VBN2EL3P0C 1 1/2 in. DN40 23 Cv 19.8 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac None 100 psi 689 kPa
VBN2EL3P0D 1 1/2 in. DN40 23 Cv 19.8 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating None 100 psi 689 kPa

Building Automation
VBN2EL3P0X 1 1/2 in. DN40 23 Cv 19.8 kvs Nickel-plated brass ball Brass No pre-assembled actuator None 100 psi 689 kPa
VBN2EL3S0A 1 1/2 in. DN40 23 Cv 19.8 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating None 100 psi 689 kPa
VBN2EL3S0B 1 1/2 in. DN40 23 Cv 19.8 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating None 100 psi 689 kPa
VBN2EL3S0C 1 1/2 in. DN40 23 Cv 19.8 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac None 100 psi 689 kPa
VBN2EL3S0D 1 1/2 in. DN40 23 Cv 19.8 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating None 100 psi 689 kPa
VBN2EL3S0X 1 1/2 in. DN40 23 Cv 19.8 kvs 316 stainless steel 316 Stainless Steel No pre-assembled actuator None 100 psi 689 kPa
VBN2EM3PRA 1 1/2 in. DN40 30 Cv 26 kvs Nickel-plated brass ball Brass Non-Spring Return Floating NEMA 3R 100 psi 689 kPa
VBN2EM3PRB 1 1/2 in. DN40 30 Cv 26 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa

Components
VBN2EM3PRC 1 1/2 in. DN40 30 Cv 26 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa

Commercial
VBN2EM3PRD 1 1/2 in. DN40 30 Cv 26 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa
VBN2EM3SRA 1 1/2 in. DN40 30 Cv 26 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating NEMA 3R 100 psi 689 kPa
VBN2EM3SRB 1 1/2 in. DN40 30 Cv 26 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa
VBN2EM3SRC 1 1/2 in. DN40 30 Cv 26 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa
VBN2EM3SRD 1 1/2 in. DN40 30 Cv 26 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa
VBN2EM3P0A 1 1/2 in. DN40 30 Cv 26 kvs Nickel-plated brass ball Brass Non-Spring Return Floating None 100 psi 689 kPa
Pneumatic Controls

VBN2EM3P0B 1 1/2 in. DN40 30 Cv 26 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating None 100 psi 689 kPa
VBN2EM3P0C 1 1/2 in. DN40 30 Cv 26 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac None 100 psi 689 kPa
VBN2EM3P0D 1 1/2 in. DN40 30 Cv 26 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating None 100 psi 689 kPa
VBN2EM3P0X 1 1/2 in. DN40 30 Cv 26 kvs Nickel-plated brass ball Brass No pre-assembled actuator None 100 psi 689 kPa
VBN2EM3S0A 1 1/2 in. DN40 30 Cv 26 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating None 100 psi 689 kPa
VBN2EM3S0B 1 1/2 in. DN40 30 Cv 26 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating None 100 psi 689 kPa
VBN2EM3S0C 1 1/2 in. DN40 30 Cv 26 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac None 100 psi 689 kPa
Industrial Combustion

VBN2EM3S0D 1 1/2 in. DN40 30 Cv 26 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating None 100 psi 689 kPa
VBN2EM3S0X 1 1/2 in. DN40 30 Cv 26 kvs 316 stainless steel 316 Stainless Steel No pre-assembled actuator None 100 psi 689 kPa
Controls

VBN2EN3PRA 1 1/2 in. DN40 41 Cv 35 kvs Nickel-plated brass ball Brass Non-Spring Return Floating NEMA 3R 100 psi 689 kPa
VBN2EN3PRB 1 1/2 in. DN40 41 Cv 35 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa

70-6910 583
Control Ball Valves
Maximum
Close-off
Weather
Valve Size Flow Capacity Materials Pressure
Enclo-
Product Number (inch) DN (Cv) (Kv) (Plug/Ball/Disc) (Stem) Actuation sure (psi) (kPa)
VBN2EN3PRC 1 1/2 in. DN40 41 Cv 35 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa
VBN2EN3PRD 1 1/2 in. DN40 41 Cv 35 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa
VBN2EN3SRA 1 1/2 in. DN40 41 Cv 35 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating NEMA 3R 100 psi 689 kPa
VBN2EN3SRB 1 1/2 in. DN40 41 Cv 35 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa
VBN2EN3SRC 1 1/2 in. DN40 41 Cv 35 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa
VBN2EN3SRD 1 1/2 in. DN40 41 Cv 35 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa
VBN2EN3P0A 1 1/2 in. DN40 41 Cv 35 kvs Nickel-plated brass ball Brass Non-Spring Return Floating None 100 psi 689 kPa
VBN2EN3P0B 1 1/2 in. DN40 41 Cv 35 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating None 100 psi 689 kPa
VBN2EN3P0C 1 1/2 in. DN40 41 Cv 35 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac None 100 psi 689 kPa
VBN2EN3P0D 1 1/2 in. DN40 41 Cv 35 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating None 100 psi 689 kPa
VBN2EN3P0X 1 1/2 in. DN40 41 Cv 35 kvs Nickel-plated brass ball Brass No pre-assembled actuator None 100 psi 689 kPa
VBN2EN3S0A 1 1/2 in. DN40 41 Cv 35 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating None 100 psi 689 kPa
VBN2EN3S0B 1 1/2 in. DN40 41 Cv 35 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating None 100 psi 689 kPa
VBN2EN3S0C 1 1/2 in. DN40 41 Cv 35 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac None 100 psi 689 kPa
VBN2EN3S0D 1 1/2 in. DN40 41 Cv 35 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating None 100 psi 689 kPa
VBN2EN3S0X 1 1/2 in. DN40 41 Cv 35 kvs 316 stainless steel 316 Stainless Steel No pre-assembled actuator None 100 psi 689 kPa
VBN2FN3PRA 2 in. DN50 42 Cv 36 kvs Nickel-plated brass ball Brass Non-Spring Return Floating NEMA 3R 100 psi 689 kPa
VBN2FN3PRB 2 in. DN50 42 Cv 36 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa
VBN2FN3PRC 2 in. DN50 42 Cv 36 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa
VBN2FN3PRD 2 in. DN50 42 Cv 36 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa
VBN2FN3SRA 2 in. DN50 42 Cv 36 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating NEMA 3R 100 psi 689 kPa
VBN2FN3SRB 2 in. DN50 42 Cv 36 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa
VBN2FN3SRC 2 in. DN50 42 Cv 36 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa
VBN2FN3SRD 2 in. DN50 42 Cv 36 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa
VBN2FN3P0A 2 in. DN50 42 Cv 36 kvs Nickel-plated brass ball Brass Non-Spring Return Floating None 100 psi 689 kPa
VBN2FN3P0B 2 in. DN50 42 Cv 36 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating None 100 psi 689 kPa
VBN2FN3P0C 2 in. DN50 42 Cv 36 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac None 100 psi 689 kPa
VBN2FN3P0D 2 in. DN50 42 Cv 36 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating None 100 psi 689 kPa
VBN2FN3P0X 2 in. DN50 42 Cv 36 kvs Nickel-plated brass ball Brass No pre-assembled actuator None 100 psi 689 kPa
VBN2FN3S0A 2 in. DN50 42 Cv 36 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating None 100 psi 689 kPa
VBN2FN3S0B 2 in. DN50 42 Cv 36 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating None 100 psi 689 kPa
VBN2FN3S0C 2 in. DN50 42 Cv 36 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac None 100 psi 689 kPa
VBN2FN3S0D 2 in. DN50 42 Cv 36 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating None 100 psi 689 kPa
VBN2FN3S0X 2 in. DN50 42 Cv 36 kvs 316 stainless steel 316 Stainless Steel No pre-assembled actuator None 100 psi 689 kPa
VBN2FP3PRA 2 in. DN50 57 Cv 49 kvs Nickel-plated brass ball Brass Non-Spring Return Floating NEMA 3R 100 psi 689 kPa
VBN2FP3PRB 2 in. DN50 57 Cv 49 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa
VBN2FP3PRC 2 in. DN50 57 Cv 49 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa
VBN2FP3PRD 2 in. DN50 57 Cv 49 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa
VBN2FP3SRA 2 in. DN50 57 Cv 49 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating NEMA 3R 100 psi 689 kPa
VBN2FP3SRB 2 in. DN50 57 Cv 49 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa
VBN2FP3SRC 2 in. DN50 57 Cv 49 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa
VBN2FP3SRD 2 in. DN50 57 Cv 49 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa
VBN2FP3P0A 2 in. DN50 57 Cv 49 kvs Nickel-plated brass ball Brass Non-Spring Return Floating None 100 psi 689 kPa
VBN2FP3P0B 2 in. DN50 57 Cv 49 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating None 100 psi 689 kPa
VBN2FP3P0C 2 in. DN50 57 Cv 49 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac None 100 psi 689 kPa
VBN2FP3P0D 2 in. DN50 57 Cv 49 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating None 100 psi 689 kPa
VBN2FP3P0X 2 in. DN50 57 Cv 49 kvs Nickel-plated brass ball Brass No pre-assembled actuator None 100 psi 689 kPa
VBN2FP3S0A 2 in. DN50 57 Cv 49 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating None 100 psi 689 kPa
VBN2FP3S0B 2 in. DN50 57 Cv 49 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating None 100 psi 689 kPa
VBN2FP3S0C 2 in. DN50 57 Cv 49 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac None 100 psi 689 kPa
VBN2FP3S0D 2 in. DN50 57 Cv 49 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating None 100 psi 689 kPa
VBN2FP3S0X 2 in. DN50 57 Cv 49 kvs 316 stainless steel 316 Stainless Steel No pre-assembled actuator None 100 psi 689 kPa
VBN2FR3PRA 2 in. DN50 71 Cv 61 kvs Nickel-plated brass ball Brass Non-Spring Return Floating NEMA 3R 100 psi 689 kPa
VBN2FR3PRB 2 in. DN50 71 Cv 61 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa
VBN2FR3PRC 2 in. DN50 71 Cv 61 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa
VBN2FR3PRD 2 in. DN50 71 Cv 61 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa
VBN2FR3SRA 2 in. DN50 71 Cv 61 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating NEMA 3R 100 psi 689 kPa
VBN2FR3SRB 2 in. DN50 71 Cv 61 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa
VBN2FR3SRC 2 in. DN50 71 Cv 61 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa

584 customer.honeywell.com 70-6910


Control Ball Valves

Controls
Maximum

Home
Close-off
Weather
Valve Size Flow Capacity Materials Pressure
Enclo-
Product Number (inch) DN (Cv) (Kv) (Plug/Ball/Disc) (Stem) Actuation sure (psi) (kPa)
VBN2FR3SRD 2 in. DN50 71 Cv 61 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa
VBN2FR3P0A 2 in. DN50 71 Cv 61 kvs Nickel-plated brass ball Brass Non-Spring Return Floating None 100 psi 689 kPa
VBN2FR3P0B 2 in. DN50 71 Cv 61 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating None 100 psi 689 kPa

Indoor Air Quality


VBN2FR3P0C 2 in. DN50 71 Cv 61 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac None 100 psi 689 kPa
VBN2FR3P0D 2 in. DN50 71 Cv 61 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating None 100 psi 689 kPa
VBN2FR3P0X 2 in. DN50 71 Cv 61 kvs Nickel-plated brass ball Brass No pre-assembled actuator None 100 psi 689 kPa
VBN2FR3S0A 2 in. DN50 71 Cv 61 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating None 100 psi 689 kPa
VBN2FR3S0B 2 in. DN50 71 Cv 61 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating None 100 psi 689 kPa
VBN2FR3S0C 2 in. DN50 71 Cv 61 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac None 100 psi 689 kPa
VBN2FR3S0D 2 in. DN50 71 Cv 61 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating None 100 psi 689 kPa

Combustion Controls
VBN2FR3S0X 2 in. DN50 71 Cv 61 kvs 316 stainless steel 316 Stainless Steel No pre-assembled actuator None 100 psi 689 kPa
VBN2FS3PRA 2 in. DN50 100 Cv 86 kvs Nickel-plated brass ball Brass Non-Spring Return Floating NEMA 3R 100 psi 689 kPa

Residential
VBN2FS3PRB 2 in. DN50 100 Cv 86 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa
VBN2FS3PRC 2 in. DN50 100 Cv 86 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa
VBN2FS3PRD 2 in. DN50 100 Cv 86 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa
VBN2FS3SRA 2 in. DN50 100 Cv 86 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating NEMA 3R 100 psi 689 kPa
VBN2FS3SRB 2 in. DN50 100 Cv 86 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa
VBN2FS3SRC 2 in. DN50 100 Cv 86 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa

Hydronic Controls
VBN2FS3SRD 2 in. DN50 100 Cv 86 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa
VBN2FS3P0A 2 in. DN50 100 Cv 86 kvs Nickel-plated brass ball Brass Non-Spring Return Floating None 100 psi 689 kPa
VBN2FS3P0B 2 in. DN50 100 Cv 86 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating None 100 psi 689 kPa
VBN2FS3P0C 2 in. DN50 100 Cv 86 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac None 100 psi 689 kPa
VBN2FS3P0D 2 in. DN50 100 Cv 86 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating None 100 psi 689 kPa
VBN2FS3P0X 2 in. DN50 100 Cv 86 kvs Nickel-plated brass ball Brass No pre-assembled actuator None 100 psi 689 kPa
VBN2FS3S0A 2 in. DN50 100 Cv 86 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating None 100 psi 689 kPa
VBN2FS3S0B 2 in. DN50 100 Cv 86 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating None 100 psi 689 kPa
VBN2FS3S0C 2 in. DN50 100 Cv 86 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac None 100 psi 689 kPa

Controls
Water
VBN2FS3S0D 2 in. DN50 100 Cv 86 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating None 100 psi 689 kPa
VBN2FS3S0X 2 in. DN50 100 Cv 86 kvs 316 stainless steel 316 Stainless Steel No pre-assembled actuator None 100 psi 689 kPa
VBN2F13PRA 2 in. DN50 210 Cv 181 kvs Nickel-plated brass ball Brass Non-Spring Return Floating NEMA 3R 100 psi 689 kPa
VBN2F13PRB 2 in. DN50 210 Cv 181 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa
VBN2F13PRC 2 in. DN50 210 Cv 181 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa
VBN2F13PRD 2 in. DN50 210 Cv 181 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa

Building Automation
VBN2F13SRA 2 in. DN50 210 Cv 181 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating NEMA 3R 100 psi 689 kPa
VBN2F13SRB 2 in. DN50 210 Cv 181 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa
VBN2F13SRC 2 in. DN50 210 Cv 181 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa
VBN2F13SRD 2 in. DN50 210 Cv 181 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa
VBN2F13P0A 2 in. DN50 210 Cv 181 kvs Nickel-plated brass ball Brass Non-Spring Return Floating None 100 psi 689 kPa
VBN2F13P0B 2 in. DN50 210 Cv 181 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating None 100 psi 689 kPa
VBN2F13P0C 2 in. DN50 210 Cv 181 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac None 100 psi 689 kPa
VBN2F13P0D 2 in. DN50 210 Cv 181 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating None 100 psi 689 kPa

Components
VBN2F13P0X 2 in. DN50 210 Cv 181 kvs Nickel-plated brass ball Brass No pre-assembled actuator None 100 psi 689 kPa

Commercial
VBN2F13S0A 2 in. DN50 210 Cv 181 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating None 100 psi 689 kPa
VBN2F13S0B 2 in. DN50 210 Cv 181 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating None 100 psi 689 kPa
VBN2F13S0C 2 in. DN50 210 Cv 181 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac None 100 psi 689 kPa
VBN2F13S0D 2 in. DN50 210 Cv 181 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating None 100 psi 689 kPa
VBN2F13S0X 2 in. DN50 210 Cv 181 kvs 316 stainless steel 316 Stainless Steel No pre-assembled actuator None 100 psi 689 kPa
VBN2GN3PRA 2 1/2 in. DN65 45 Cv 39 kvs Nickel-plated brass ball Brass Non-Spring Return Floating NEMA 3R 100 psi 689 kPa
Pneumatic Controls

VBN2GN3PRB 2 1/2 in. DN65 45 Cv 39 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa
VBN2GN3PRC 2 1/2 in. DN65 45 Cv 39 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa
VBN2GN3PRD 2 1/2 in. DN65 45 Cv 39 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa
VBN2GN3SRA 2 1/2 in. DN65 45 Cv 39 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating NEMA 3R 100 psi 689 kPa
VBN2GN3SRB 2 1/2 in. DN65 45 Cv 39 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa
VBN2GN3SRC 2 1/2 in. DN65 45 Cv 39 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa
VBN2GN3SRD 2 1/2 in. DN65 45 Cv 39 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa
Industrial Combustion

VBN2GN3P0A 2 1/2 in. DN65 45 Cv 39 kvs Nickel-plated brass ball Brass Non-Spring Return Floating None 100 psi 689 kPa
VBN2GN3P0B 2 1/2 in. DN65 45 Cv 39 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating None 100 psi 689 kPa
Controls

VBN2GN3P0C 2 1/2 in. DN65 45 Cv 39 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac None 100 psi 689 kPa
VBN2GN3P0D 2 1/2 in. DN65 45 Cv 39 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating None 100 psi 689 kPa

70-6910 585
Control Ball Valves
Maximum
Close-off
Weather
Valve Size Flow Capacity Materials Pressure
Enclo-
Product Number (inch) DN (Cv) (Kv) (Plug/Ball/Disc) (Stem) Actuation sure (psi) (kPa)
VBN2GN3P0X 2 1/2 in. DN65 45 Cv 39 kvs Nickel-plated brass ball Brass No pre-assembled actuator None 100 psi 689 kPa
VBN2GN3S0A 2 1/2 in. DN65 45 Cv 39 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating None 100 psi 689 kPa
VBN2GN3S0B 2 1/2 in. DN65 45 Cv 39 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating None 100 psi 689 kPa
VBN2GN3S0C 2 1/2 in. DN65 45 Cv 39 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac None 100 psi 689 kPa
VBN2GN3S0D 2 1/2 in. DN65 45 Cv 39 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating None 100 psi 689 kPa
VBN2GN3S0X 2 1/2 in. DN65 45 Cv 39 kvs 316 stainless steel 316 Stainless Steel No pre-assembled actuator None 100 psi 689 kPa
VBN2GP3PRA 2 1/2 in. DN65 55 Cv 47 kvs Nickel-plated brass ball Brass Non-Spring Return Floating NEMA 3R 100 psi 689 kPa
VBN2GP3PRB 2 1/2 in. DN65 55 Cv 47 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa
VBN2GP3PRC 2 1/2 in. DN65 55 Cv 47 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa
VBN2GP3PRD 2 1/2 in. DN65 55 Cv 47 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa
VBN2GP3SRA 2 1/2 in. DN65 55 Cv 47 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating NEMA 3R 100 psi 689 kPa
VBN2GP3SRB 2 1/2 in. DN65 55 Cv 47 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa
VBN2GP3SRC 2 1/2 in. DN65 55 Cv 47 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa
VBN2GP3SRD 2 1/2 in. DN65 55 Cv 47 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa
VBN2GP3P0A 2 1/2 in. DN65 55 Cv 47 kvs Nickel-plated brass ball Brass Non-Spring Return Floating None 100 psi 689 kPa
VBN2GP3P0B 2 1/2 in. DN65 55 Cv 47 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating None 100 psi 689 kPa
VBN2GP3P0C 2 1/2 in. DN65 55 Cv 47 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac None 100 psi 689 kPa
VBN2GP3P0D 2 1/2 in. DN65 55 Cv 47 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating None 100 psi 689 kPa
VBN2GP3P0X 2 1/2 in. DN65 55 Cv 47 kvs Nickel-plated brass ball Brass No pre-assembled actuator None 100 psi 689 kPa
VBN2GP3S0A 2 1/2 in. DN65 55 Cv 47 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating None 100 psi 689 kPa
VBN2GP3S0B 2 1/2 in. DN65 55 Cv 47 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating None 100 psi 689 kPa
VBN2GP3S0C 2 1/2 in. DN65 55 Cv 47 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac None 100 psi 689 kPa
VBN2GP3S0D 2 1/2 in. DN65 55 Cv 47 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating None 100 psi 689 kPa
VBN2GP3S0X 2 1/2 in. DN65 55 Cv 47 kvs 316 stainless steel 316 Stainless Steel No pre-assembled actuator None 100 psi 689 kPa
VBN2GR3PRA 2 1/2 in. DN65 72 Cv 62 kvs Nickel-plated brass ball Brass Non-Spring Return Floating NEMA 3R 100 psi 689 kPa
VBN2GR3PRB 2 1/2 in. DN65 72 Cv 62 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa
VBN2GR3PRC 2 1/2 in. DN65 72 Cv 62 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa
VBN2GR3PRD 2 1/2 in. DN65 72 Cv 62 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa
VBN2GR3SRA 2 1/2 in. DN65 72 Cv 62 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating NEMA 3R 100 psi 689 kPa
VBN2GR3SRB 2 1/2 in. DN65 72 Cv 62 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa
VBN2GR3SRC 2 1/2 in. DN65 72 Cv 62 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa
VBN2GR3SRD 2 1/2 in. DN65 72 Cv 62 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa
VBN2GR3P0A 2 1/2 in. DN65 72 Cv 62 kvs Nickel-plated brass ball Brass Non-Spring Return Floating None 100 psi 689 kPa
VBN2GR3P0B 2 1/2 in. DN65 72 Cv 62 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating None 100 psi 689 kPa
VBN2GR3P0C 2 1/2 in. DN65 72 Cv 62 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac None 100 psi 689 kPa
VBN2GR3P0D 2 1/2 in. DN65 72 Cv 62 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating None 100 psi 689 kPa
VBN2GR3P0X 2 1/2 in. DN65 72 Cv 62 kvs Nickel-plated brass ball Brass No pre-assembled actuator None 100 psi 689 kPa
VBN2GR3S0A 2 1/2 in. DN65 72 Cv 62 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating None 100 psi 689 kPa
VBN2GR3S0B 2 1/2 in. DN65 72 Cv 62 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating None 100 psi 689 kPa
VBN2GR3S0C 2 1/2 in. DN65 72 Cv 62 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac None 100 psi 689 kPa
VBN2GR3S0D 2 1/2 in. DN65 72 Cv 62 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating None 100 psi 689 kPa
VBN2GR3S0X 2 1/2 in. DN65 72 Cv 62 kvs 316 stainless steel 316 Stainless Steel No pre-assembled actuator None 100 psi 689 kPa
VBN2GS3PRA 2 1/2 in. DN65 101 Cv 87 kvs Nickel-plated brass ball Brass Non-Spring Return Floating NEMA 3R 100 psi 689 kPa
VBN2GS3PRB 2 1/2 in. DN65 101 Cv 87 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa
VBN2GS3PRC 2 1/2 in. DN65 101 Cv 87 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa
VBN2GS3PRD 2 1/2 in. DN65 101 Cv 87 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa
VBN2GS3SRA 2 1/2 in. DN65 101 Cv 87 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating NEMA 3R 100 psi 689 kPa
VBN2GS3SRB 2 1/2 in. DN65 101 Cv 87 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa
VBN2GS3SRC 2 1/2 in. DN65 101 Cv 87 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa
VBN2GS3SRD 2 1/2 in. DN65 101 Cv 87 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa
VBN2GS3P0A 2 1/2 in. DN65 101 Cv 87 kvs Nickel-plated brass ball Brass Non-Spring Return Floating None 100 psi 689 kPa
VBN2GS3P0B 2 1/2 in. DN65 101 Cv 87 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating None 100 psi 689 kPa
VBN2GS3P0C 2 1/2 in. DN65 101 Cv 87 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac None 100 psi 689 kPa
VBN2GS3P0D 2 1/2 in. DN65 101 Cv 87 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating None 100 psi 689 kPa
VBN2GS3P0X 2 1/2 in. DN65 101 Cv 87 kvs Nickel-plated brass ball Brass No pre-assembled actuator None 100 psi 689 kPa
VBN2GS3S0A 2 1/2 in. DN65 101 Cv 87 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating None 100 psi 689 kPa
VBN2GS3S0B 2 1/2 in. DN65 101 Cv 87 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating None 100 psi 689 kPa
VBN2GS3S0C 2 1/2 in. DN65 101 Cv 87 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac None 100 psi 689 kPa
VBN2GS3S0D 2 1/2 in. DN65 101 Cv 87 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating None 100 psi 689 kPa

586 customer.honeywell.com 70-6910


Control Ball Valves

Controls
Maximum

Home
Close-off
Weather
Valve Size Flow Capacity Materials Pressure
Enclo-
Product Number (inch) DN (Cv) (Kv) (Plug/Ball/Disc) (Stem) Actuation sure (psi) (kPa)
VBN2GS3S0X 2 1/2 in. DN65 101 Cv 87 kvs 316 stainless steel 316 Stainless Steel No pre-assembled actuator None 100 psi 689 kPa
VBN2GU3PRA 2 1/2 in. DN65 162 Cv 139 kvs Nickel-plated brass ball Brass Non-Spring Return Floating NEMA 3R 100 psi 689 kPa
VBN2GU3PRB 2 1/2 in. DN65 162 Cv 139 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa

Indoor Air Quality


VBN2GU3PRC 2 1/2 in. DN65 162 Cv 139 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa
VBN2GU3PRD 2 1/2 in. DN65 162 Cv 139 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa
VBN2GU3SRA 2 1/2 in. DN65 162 Cv 139 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating NEMA 3R 100 psi 689 kPa
VBN2GU3SRB 2 1/2 in. DN65 162 Cv 139 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa
VBN2GU3SRC 2 1/2 in. DN65 162 Cv 139 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa
VBN2GU3SRD 2 1/2 in. DN65 162 Cv 139 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa
VBN2GU3P0A 2 1/2 in. DN65 162 Cv 139 kvs Nickel-plated brass ball Brass Non-Spring Return Floating None 100 psi 689 kPa

Combustion Controls
VBN2GU3P0B 2 1/2 in. DN65 162 Cv 139 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating None 100 psi 689 kPa
VBN2GU3P0C 2 1/2 in. DN65 162 Cv 139 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac None 100 psi 689 kPa

Residential
VBN2GU3P0D 2 1/2 in. DN65 162 Cv 139 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating None 100 psi 689 kPa
VBN2GU3P0X 2 1/2 in. DN65 162 Cv 139 kvs Nickel-plated brass ball Brass No pre-assembled actuator None 100 psi 689 kPa
VBN2GU3S0A 2 1/2 in. DN65 162 Cv 139 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating None 100 psi 689 kPa
VBN2GU3S0B 2 1/2 in. DN65 162 Cv 139 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating None 100 psi 689 kPa
VBN2GU3S0C 2 1/2 in. DN65 162 Cv 139 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac None 100 psi 689 kPa
VBN2GU3S0D 2 1/2 in. DN65 162 Cv 139 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating None 100 psi 689 kPa

Hydronic Controls
VBN2GU3S0X 2 1/2 in. DN65 162 Cv 139 kvs 316 stainless steel 316 Stainless Steel No pre-assembled actuator None 100 psi 689 kPa
VBN2HN3PRA 3 in. DN80 49 Cv 42 kvs Nickel-plated brass ball Brass Non-Spring Return Floating NEMA 3R 100 psi 689 kPa
VBN2HN3PRB 3 in. DN80 49 Cv 42 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa
VBN2HN3PRC 3 in. DN80 49 Cv 42 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa
VBN2HN3PRD 3 in. DN80 49 Cv 42 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa
VBN2HN3SRA 3 in. DN80 49 Cv 42 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating NEMA 3R 100 psi 689 kPa
VBN2HN3SRB 3 in. DN80 49 Cv 42 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa
VBN2HN3SRC 3 in. DN80 49 Cv 42 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa
VBN2HN3SRD 3 in. DN80 49 Cv 42 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa

Controls
Water
VBN2HN3P0A 3 in. DN80 49 Cv 42 kvs Nickel-plated brass ball Brass Non-Spring Return Floating None 100 psi 689 kPa
VBN2HN3P0B 3 in. DN80 49 Cv 42 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating None 100 psi 689 kPa
VBN2HN3P0C 3 in. DN80 49 Cv 42 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac None 100 psi 689 kPa
VBN2HN3P0D 3 in. DN80 49 Cv 42 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating None 100 psi 689 kPa
VBN2HN3P0X 3 in. DN80 49 Cv 42 kvs Nickel-plated brass ball Brass No pre-assembled actuator None 100 psi 689 kPa
VBN2HN3S0A 3 in. DN80 49 Cv 42 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating None 100 psi 689 kPa

Building Automation
VBN2HN3S0B 3 in. DN80 49 Cv 42 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating None 100 psi 689 kPa
VBN2HN3S0C 3 in. DN80 49 Cv 42 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac None 100 psi 689 kPa
VBN2HN3S0D 3 in. DN80 49 Cv 42 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating None 100 psi 689 kPa
VBN2HN3S0X 3 in. DN80 49 Cv 42 kvs 316 stainless steel 316 Stainless Steel No pre-assembled actuator None 100 psi 689 kPa
VBN2HP3PRA 3 in. DN80 63 Cv 54 kvs Nickel-plated brass ball Brass Non-Spring Return Floating NEMA 3R 100 psi 689 kPa
VBN2HP3PRB 3 in. DN80 63 Cv 54 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa
VBN2HP3PRC 3 in. DN80 63 Cv 54 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa
VBN2HP3PRD 3 in. DN80 63 Cv 54 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa

Components
VBN2HP3SRA 3 in. DN80 63 Cv 54 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating NEMA 3R 100 psi 689 kPa

Commercial
VBN2HP3SRB 3 in. DN80 63 Cv 54 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa
VBN2HP3SRC 3 in. DN80 63 Cv 54 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa
VBN2HP3SRD 3 in. DN80 63 Cv 54 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa
VBN2HP3P0A 3 in. DN80 63 Cv 54 kvs Nickel-plated brass ball Brass Non-Spring Return Floating None 100 psi 689 kPa
VBN2HP3P0B 3 in. DN80 63 Cv 54 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating None 100 psi 689 kPa
VBN2HP3P0C 3 in. DN80 63 Cv 54 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac None 100 psi 689 kPa
Pneumatic Controls

VBN2HP3P0D 3 in. DN80 63 Cv 54 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating None 100 psi 689 kPa
VBN2HP3P0X 3 in. DN80 63 Cv 54 kvs Nickel-plated brass ball Brass No pre-assembled actuator None 100 psi 689 kPa
VBN2HP3S0A 3 in. DN80 63 Cv 54 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating None 100 psi 689 kPa
VBN2HP3S0B 3 in. DN80 63 Cv 54 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating None 100 psi 689 kPa
VBN2HP3S0C 3 in. DN80 63 Cv 54 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac None 100 psi 689 kPa
VBN2HP3S0D 3 in. DN80 63 Cv 54 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating None 100 psi 689 kPa
VBN2HP3S0X 3 in. DN80 63 Cv 54 kvs 316 stainless steel 316 Stainless Steel No pre-assembled actuator None 100 psi 689 kPa
Industrial Combustion

VBN2HR3PRA 3 in. DN80 82 Cv 71 kvs Nickel-plated brass ball Brass Non-Spring Return Floating NEMA 3R 100 psi 689 kPa
VBN2HR3PRB 3 in. DN80 82 Cv 71 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa
Controls

VBN2HR3PRC 3 in. DN80 82 Cv 71 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa
VBN2HR3PRD 3 in. DN80 82 Cv 71 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa

70-6910 587
Control Ball Valves
Maximum
Close-off
Weather
Valve Size Flow Capacity Materials Pressure
Enclo-
Product Number (inch) DN (Cv) (Kv) (Plug/Ball/Disc) (Stem) Actuation sure (psi) (kPa)
VBN2HR3SRA 3 in. DN80 82 Cv 71 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating NEMA 3R 100 psi 689 kPa
VBN2HR3SRB 3 in. DN80 82 Cv 71 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa
VBN2HR3SRC 3 in. DN80 82 Cv 71 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa
VBN2HR3SRD 3 in. DN80 82 Cv 71 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa
VBN2HR3P0A 3 in. DN80 82 Cv 71 kvs Nickel-plated brass ball Brass Non-Spring Return Floating None 100 psi 689 kPa
VBN2HR3P0B 3 in. DN80 82 Cv 71 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating None 100 psi 689 kPa
VBN2HR3P0C 3 in. DN80 82 Cv 71 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac None 100 psi 689 kPa
VBN2HR3P0D 3 in. DN80 82 Cv 71 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating None 100 psi 689 kPa
VBN2HR3P0X 3 in. DN80 82 Cv 71 kvs Nickel-plated brass ball Brass No pre-assembled actuator None 100 psi 689 kPa
VBN2HR3S0A 3 in. DN80 82 Cv 71 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating None 100 psi 689 kPa
VBN2HR3S0B 3 in. DN80 82 Cv 71 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating None 100 psi 689 kPa
VBN2HR3S0C 3 in. DN80 82 Cv 71 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac None 100 psi 689 kPa
VBN2HR3S0D 3 in. DN80 82 Cv 71 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating None 100 psi 689 kPa
VBN2HR3S0X 3 in. DN80 82 Cv 71 kvs 316 stainless steel 316 Stainless Steel No pre-assembled actuator None 100 psi 689 kPa
VBN2HT3PRA 3 in. DN80 124 Cv 107 kvs Nickel-plated brass ball Brass Non-Spring Return Floating NEMA 3R 100 psi 689 kPa
VBN2HT3PRB 3 in. DN80 124 Cv 107 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa
VBN2HT3PRC 3 in. DN80 124 Cv 107 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa
VBN2HT3PRD 3 in. DN80 124 Cv 107 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa
VBN2HT3SRA 3 in. DN80 124 Cv 107 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating NEMA 3R 100 psi 689 kPa
VBN2HT3SRB 3 in. DN80 124 Cv 107 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa
VBN2HT3SRC 3 in. DN80 124 Cv 107 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa
VBN2HT3SRD 3 in. DN80 124 Cv 107 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa
VBN2HT3P0A 3 in. DN80 124 Cv 107 kvs Nickel-plated brass ball Brass Non-Spring Return Floating None 100 psi 689 kPa
VBN2HT3P0B 3 in. DN80 124 Cv 107 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating None 100 psi 689 kPa
VBN2HT3P0C 3 in. DN80 124 Cv 107 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac None 100 psi 689 kPa
VBN2HT3P0D 3 in. DN80 124 Cv 107 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating None 100 psi 689 kPa
VBN2HT3P0X 3 in. DN80 124 Cv 107 kvs Nickel-plated brass ball Brass No pre-assembled actuator None 100 psi 689 kPa
VBN2HT3S0A 3 in. DN80 124 Cv 107 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating None 100 psi 689 kPa
VBN2HT3S0B 3 in. DN80 124 Cv 107 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating None 100 psi 689 kPa
VBN2HT3S0C 3 in. DN80 124 Cv 107 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac None 100 psi 689 kPa
VBN2HT3S0D 3 in. DN80 124 Cv 107 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating None 100 psi 689 kPa
VBN2HT3S0X 3 in. DN80 124 Cv 107 kvs 316 stainless steel 316 Stainless Steel No pre-assembled actuator None 100 psi 689 kPa

Valves with Linear Flow Characteristic

Maximum
Close-off
Weather
Valve Size Flow Capacity Materials Pressure
Enclo-
Product Number (inch) DN (Cv) (Kv) (Plug/Ball/Disc) (Stem) Actuation sure (psi) (kPa)
VBN2AK3PRA 1/2 in. DN15 11.7 Cv 10.1 kvs Nickel-plated brass ball Brass Non-Spring Return Floating NEMA 3R 130 psi 896 kPa
VBN2AK3PRB 1/2 in. DN15 11.7 Cv 10.1 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating NEMA 3R 130 psi 896 kPa
VBN2AK3PRC 1/2 in. DN15 11.7 Cv 10.1 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac NEMA 3R 130 psi 896 kPa
VBN2AK3PRD 1/2 in. DN15 11.7 Cv 10.1 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating NEMA 3R 130 psi 896 kPa
VBN2AK3SRA 1/2 in. DN15 11.7 Cv 10.1 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating NEMA 3R 130 psi 896 kPa
VBN2AK3SRB 1/2 in. DN15 11.7 Cv 10.1 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating NEMA 3R 130 psi 896 kPa
VBN2AK3SRC 1/2 in. DN15 11.7 Cv 10.1 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac NEMA 3R 130 psi 896 kPa
VBN2AK3SRD 1/2 in. DN15 11.7 Cv 10.1 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating NEMA 3R 130 psi 896 kPa
VBN2AK3P0A 1/2 in. DN15 11.7 Cv 10.1 kvs Nickel-plated brass ball Brass Non-Spring Return Floating None 130 psi 896 kPa
VBN2AK3P0B 1/2 in. DN15 11.7 Cv 10.1 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating None 130 psi 896 kPa
VBN2AK3P0C 1/2 in. DN15 11.7 Cv 10.1 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac None 130 psi 896 kPa
VBN2AK3P0D 1/2 in. DN15 11.7 Cv 10.1 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating None 130 psi 896 kPa
VBN2AK3P0X 1/2 in. DN15 11.7 Cv 10.1 kvs Nickel-plated brass ball Brass No pre-assembled actuator None 130 psi 896 kPa
VBN2AK3S0A 1/2 in. DN15 11.7 Cv 10.1 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating None 130 psi 896 kPa
VBN2AK3S0B 1/2 in. DN15 11.7 Cv 10.1 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating None 130 psi 896 kPa
VBN2AK3S0C 1/2 in. DN15 11.7 Cv 10.1 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac None 130 psi 896 kPa
VBN2AK3S0D 1/2 in. DN15 11.7 Cv 10.1 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating None 130 psi 896 kPa
VBN2AK3S0X 1/2 in. DN15 11.7 Cv 10.1 kvs 316 stainless steel 316 Stainless Steel No pre-assembled actuator None 130 psi 896 kPa
VBN2BL3PRA 3/4 in. DN20 14.7 Cv 12.6 kvs Nickel-plated brass ball Brass Non-Spring Return Floating NEMA 3R 130 psi 896 kPa
VBN2BL3PRB 3/4 in. DN20 14.7 Cv 12.6 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating NEMA 3R 130 psi 896 kPa
VBN2BL3PRC 3/4 in. DN20 14.7 Cv 12.6 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac NEMA 3R 130 psi 896 kPa

588 customer.honeywell.com 70-6910


Control Ball Valves

Controls
Maximum

Home
Close-off
Weather
Valve Size Flow Capacity Materials Pressure
Enclo-
Product Number (inch) DN (Cv) (Kv) (Plug/Ball/Disc) (Stem) Actuation sure (psi) (kPa)
VBN2BL3PRD 3/4 in. DN20 14.7 Cv 12.6 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating NEMA 3R 130 psi 896 kPa
VBN2BL3SRA 3/4 in. DN20 14.7 Cv 12.6 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating NEMA 3R 130 psi 896 kPa
VBN2BL3SRB 3/4 in. DN20 14.7 Cv 12.6 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating NEMA 3R 130 psi 896 kPa

Indoor Air Quality


VBN2BL3SRC 3/4 in. DN20 14.7 Cv 12.6 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac NEMA 3R 130 psi 896 kPa
VBN2BL3SRD 3/4 in. DN20 14.7 Cv 12.6 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating NEMA 3R 130 psi 896 kPa
VBN2BL3P0A 3/4 in. DN20 14.7 Cv 12.6 kvs Nickel-plated brass ball Brass Non-Spring Return Floating None 130 psi 896 kPa
VBN2BL3P0B 3/4 in. DN20 14.7 Cv 12.6 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating None 130 psi 896 kPa
VBN2BL3P0C 3/4 in. DN20 14.7 Cv 12.6 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac None 130 psi 896 kPa
VBN2BL3P0D 3/4 in. DN20 14.7 Cv 12.6 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating None 130 psi 896 kPa
VBN2BL3P0X 3/4 in. DN20 14.7 Cv 12.6 kvs Nickel-plated brass ball Brass No pre-assembled actuator None 130 psi 896 kPa

Combustion Controls
VBN2BL3S0A 3/4 in. DN20 14.7 Cv 12.6 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating None 130 psi 896 kPa
VBN2BL3S0B 3/4 in. DN20 14.7 Cv 12.6 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating None 130 psi 896 kPa

Residential
VBN2BL3S0C 3/4 in. DN20 14.7 Cv 12.6 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac None 130 psi 896 kPa
VBN2BL3S0D 3/4 in. DN20 14.7 Cv 12.6 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating None 130 psi 896 kPa
VBN2BL3S0X 3/4 in. DN20 14.7 Cv 12.6 kvs 316 stainless steel 316 Stainless Steel No pre-assembled actuator None 130 psi 896 kPa
VBN2BM3PRA 3/4 in. DN20 29 Cv 25 kvs Nickel-plated brass ball Brass Non-Spring Return Floating NEMA 3R 130 psi 896 kPa
VBN2BM3PRB 3/4 in. DN20 29 Cv 25 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating NEMA 3R 130 psi 896 kPa
VBN2BM3PRC 3/4 in. DN20 29 Cv 25 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac NEMA 3R 130 psi 896 kPa

Hydronic Controls
VBN2BM3PRD 3/4 in. DN20 29 Cv 25 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating NEMA 3R 130 psi 896 kPa
VBN2BM3SRA 3/4 in. DN20 29 Cv 25 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating NEMA 3R 130 psi 896 kPa
VBN2BM3SRB 3/4 in. DN20 29 Cv 25 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating NEMA 3R 130 psi 896 kPa
VBN2BM3SRC 3/4 in. DN20 29 Cv 25 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac NEMA 3R 130 psi 896 kPa
VBN2BM3SRD 3/4 in. DN20 29 Cv 25 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating NEMA 3R 130 psi 896 kPa
VBN2BM3P0A 3/4 in. DN20 29 Cv 25 kvs Nickel-plated brass ball Brass Non-Spring Return Floating None 130 psi 896 kPa
VBN2BM3P0B 3/4 in. DN20 29 Cv 25 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating None 130 psi 896 kPa
VBN2BM3P0C 3/4 in. DN20 29 Cv 25 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac None 130 psi 896 kPa
VBN2BM3P0D 3/4 in. DN20 29 Cv 25 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating None 130 psi 896 kPa

Controls
Water
VBN2BM3P0X 3/4 in. DN20 29 Cv 25 kvs Nickel-plated brass ball Brass No pre-assembled actuator None 130 psi 896 kPa
VBN2BM3S0A 3/4 in. DN20 29 Cv 25 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating None 130 psi 896 kPa
VBN2BM3S0B 3/4 in. DN20 29 Cv 25 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating None 130 psi 896 kPa
VBN2BM3S0C 3/4 in. DN20 29 Cv 25 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac None 130 psi 896 kPa
VBN2BM3S0D 3/4 in. DN20 29 Cv 25 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating None 130 psi 896 kPa
VBN2BM3S0X 3/4 in. DN20 29 Cv 25 kvs 316 stainless steel 316 Stainless Steel No pre-assembled actuator None 130 psi 896 kPa

Building Automation
VBN2CN3PRA 1 in. DN25 44 Cv 38 kvs Nickel-plated brass ball Brass Non-Spring Return Floating NEMA 3R 100 psi 689 kPa
VBN2CN3PRB 1 in. DN25 44 Cv 38 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa
VBN2CN3PRC 1 in. DN25 44 Cv 38 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa
VBN2CN3PRD 1 in. DN25 44 Cv 38 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa
VBN2CN3SRA 1 in. DN25 44 Cv 38 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating NEMA 3R 100 psi 689 kPa
VBN2CN3SRB 1 in. DN25 44 Cv 38 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa
VBN2CN3SRC 1 in. DN25 44 Cv 38 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa
VBN2CN3SRD 1 in. DN25 44 Cv 38 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa

Components
VBN2CN3P0A 1 in. DN25 44 Cv 38 kvs Nickel-plated brass ball Brass Non-Spring Return Floating None 100 psi 689 kPa

Commercial
VBN2CN3P0B 1 in. DN25 44 Cv 38 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating None 100 psi 689 kPa
VBN2CN3P0C 1 in. DN25 44 Cv 38 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac None 100 psi 689 kPa
VBN2CN3P0D 1 in. DN25 44 Cv 38 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating None 100 psi 689 kPa
VBN2CN3P0X 1 in. DN25 44 Cv 38 kvs Nickel-plated brass ball Brass No pre-assembled actuator None 100 psi 689 kPa
VBN2CN3S0A 1 in. DN25 44 Cv 38 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating None 100 psi 689 kPa
VBN2CN3S0B 1 in. DN25 44 Cv 38 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating None 100 psi 689 kPa
Pneumatic Controls

VBN2CN3S0C 1 in. DN25 44 Cv 38 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac None 100 psi 689 kPa
VBN2CN3S0D 1 in. DN25 44 Cv 38 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating None 100 psi 689 kPa
VBN2CN3S0X 1 in. DN25 44 Cv 38 kvs 316 stainless steel 316 Stainless Steel No pre-assembled actuator None 100 psi 689 kPa
VBN2CP3PRA 1 in. DN25 54 Cv 46 kvs Nickel-plated brass ball Brass Non-Spring Return Floating NEMA 3R 100 psi 689 kPa
VBN2CP3PRB 1 in. DN25 54 Cv 46 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa
VBN2CP3PRC 1 in. DN25 54 Cv 46 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa
VBN2CP3PRD 1 in. DN25 54 Cv 46 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa
Industrial Combustion

VBN2CP3SRA 1 in. DN25 54 Cv 46 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating NEMA 3R 100 psi 689 kPa
VBN2CP3SRB 1 in. DN25 54 Cv 46 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa
Controls

VBN2CP3SRC 1 in. DN25 54 Cv 46 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa
VBN2CP3SRD 1 in. DN25 54 Cv 46 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa

70-6910 589
Control Ball Valves
Maximum
Close-off
Weather
Valve Size Flow Capacity Materials Pressure
Enclo-
Product Number (inch) DN (Cv) (Kv) (Plug/Ball/Disc) (Stem) Actuation sure (psi) (kPa)
VBN2CP3P0A 1 in. DN25 54 Cv 46 kvs Nickel-plated brass ball Brass Non-Spring Return Floating None 100 psi 689 kPa
VBN2CP3P0B 1 in. DN25 54 Cv 46 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating None 100 psi 689 kPa
VBN2CP3P0C 1 in. DN25 54 Cv 46 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac None 100 psi 689 kPa
VBN2CP3P0D 1 in. DN25 54 Cv 46 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating None 100 psi 689 kPa
VBN2CP3P0X 1 in. DN25 54 Cv 46 kvs Nickel-plated brass ball Brass No pre-assembled actuator None 100 psi 689 kPa
VBN2CP3S0A 1 in. DN25 54 Cv 46 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating None 100 psi 689 kPa
VBN2CP3S0B 1 in. DN25 54 Cv 46 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating None 100 psi 689 kPa
VBN2CP3S0C 1 in. DN25 54 Cv 46 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac None 100 psi 689 kPa
VBN2CP3S0D 1 in. DN25 54 Cv 46 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating None 100 psi 689 kPa
VBN2CP3S0X 1 in. DN25 54 Cv 46 kvs 316 stainless steel 316 Stainless Steel No pre-assembled actuator None 100 psi 689 kPa
VBN2DS3PRA 1 1/4 in. DN32 102 Cv 88 kvs Nickel-plated brass ball Brass Non-Spring Return Floating NEMA 3R 100 psi 689 kPa
VBN2DS3PRB 1 1/4 in. DN32 102 Cv 88 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa
VBN2DS3PRC 1 1/4 in. DN32 102 Cv 88 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa
VBN2DS3PRD 1 1/4 in. DN32 102 Cv 88 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa
VBN2DS3SRA 1 1/4 in. DN32 102 Cv 88 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating NEMA 3R 100 psi 689 kPa
VBN2DS3SRB 1 1/4 in. DN32 102 Cv 88 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa
VBN2DS3SRC 1 1/4 in. DN32 102 Cv 88 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa
VBN2DS3SRD 1 1/4 in. DN32 102 Cv 88 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa
VBN2DS3P0A 1 1/4 in. DN32 102 Cv 88 kvs Nickel-plated brass ball Brass Non-Spring Return Floating None 100 psi 689 kPa
VBN2DS3P0B 1 1/4 in. DN32 102 Cv 88 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating None 100 psi 689 kPa
VBN2DS3P0C 1 1/4 in. DN32 102 Cv 88 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac None 100 psi 689 kPa
VBN2DS3P0D 1 1/4 in. DN32 102 Cv 88 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating None 100 psi 689 kPa
VBN2DS3P0X 1 1/4 in. DN32 102 Cv 88 kvs Nickel-plated brass ball Brass No pre-assembled actuator None 100 psi 689 kPa
VBN2DS3S0A 1 1/4 in. DN32 102 Cv 88 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating None 100 psi 689 kPa
VBN2DS3S0B 1 1/4 in. DN32 102 Cv 88 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating None 100 psi 689 kPa
VBN2DS3S0C 1 1/4 in. DN32 102 Cv 88 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac None 100 psi 689 kPa
VBN2DS3S0D 1 1/4 in. DN32 102 Cv 88 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating None 100 psi 689 kPa
VBN2DS3S0X 1 1/4 in. DN32 102 Cv 88 kvs 316 stainless steel 316 Stainless Steel No pre-assembled actuator None 100 psi 689 kPa
VBN2ER3PRA 1 1/2 in. DN40 74 Cv 64 kvs Nickel-plated brass ball Brass Non-Spring Return Floating NEMA 3R 100 psi 689 kPa
VBN2ER3PRB 1 1/2 in. DN40 74 Cv 64 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa
VBN2ER3PRC 1 1/2 in. DN40 74 Cv 64 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa
VBN2ER3PRD 1 1/2 in. DN40 74 Cv 64 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa
VBN2ER3SRA 1 1/2 in. DN40 74 Cv 64 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating NEMA 3R 100 psi 689 kPa
VBN2ER3SRB 1 1/2 in. DN40 74 Cv 64 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa
VBN2ER3SRC 1 1/2 in. DN40 74 Cv 64 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa
VBN2ER3SRD 1 1/2 in. DN40 74 Cv 64 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa
VBN2ER3P0A 1 1/2 in. DN40 74 Cv 64 kvs Nickel-plated brass ball Brass Non-Spring Return Floating None 100 psi 689 kPa
VBN2ER3P0B 1 1/2 in. DN40 74 Cv 64 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating None 100 psi 689 kPa
VBN2ER3P0C 1 1/2 in. DN40 74 Cv 64 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac None 100 psi 689 kPa
VBN2ER3P0D 1 1/2 in. DN40 74 Cv 64 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating None 100 psi 689 kPa
VBN2ER3P0X 1 1/2 in. DN40 74 Cv 64 kvs Nickel-plated brass ball Brass No pre-assembled actuator None 100 psi 689 kPa
VBN2ER3S0A 1 1/2 in. DN40 74 Cv 64 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating None 100 psi 689 kPa
VBN2ER3S0B 1 1/2 in. DN40 74 Cv 64 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating None 100 psi 689 kPa
VBN2ER3S0C 1 1/2 in. DN40 74 Cv 64 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac None 100 psi 689 kPa
VBN2ER3S0D 1 1/2 in. DN40 74 Cv 64 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating None 100 psi 689 kPa
VBN2ER3S0X 1 1/2 in. DN40 74 Cv 64 kvs 316 stainless steel 316 Stainless Steel No pre-assembled actuator None 100 psi 689 kPa
VBN2E13PRA 1 1/2 in. DN40 172 Cv 148 kvs Nickel-plated brass ball Brass Non-Spring Return Floating NEMA 3R 100 psi 689 kPa
VBN2E13PRB 1 1/2 in. DN40 172 Cv 148 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa
VBN2E13PRC 1 1/2 in. DN40 172 Cv 148 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa
VBN2E13PRD 1 1/2 in. DN40 172 Cv 148 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa
VBN2E13SRA 1 1/2 in. DN40 172 Cv 148 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating NEMA 3R 100 psi 689 kPa
VBN2E13SRB 1 1/2 in. DN40 172 Cv 148 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa
VBN2E13SRC 1 1/2 in. DN40 172 Cv 148 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa
VBN2E13SRD 1 1/2 in. DN40 172 Cv 148 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa
VBN2E13P0A 1 1/2 in. DN40 172 Cv 148 kvs Nickel-plated brass ball Brass Non-Spring Return Floating None 100 psi 689 kPa
VBN2E13P0B 1 1/2 in. DN40 172 Cv 148 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating None 100 psi 689 kPa
VBN2E13P0C 1 1/2 in. DN40 172 Cv 148 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac None 100 psi 689 kPa
VBN2E13P0D 1 1/2 in. DN40 172 Cv 148 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating None 100 psi 689 kPa
VBN2E13P0X 1 1/2 in. DN40 172 Cv 148 kvs Nickel-plated brass ball Brass No pre-assembled actuator None 100 psi 689 kPa

590 customer.honeywell.com 70-6910


Control Ball Valves

Controls
Maximum

Home
Close-off
Weather
Valve Size Flow Capacity Materials Pressure
Enclo-
Product Number (inch) DN (Cv) (Kv) (Plug/Ball/Disc) (Stem) Actuation sure (psi) (kPa)
VBN2E13S0A 1 1/2 in. DN40 172 Cv 148 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating None 100 psi 689 kPa
VBN2E13S0B 1 1/2 in. DN40 172 Cv 148 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating None 100 psi 689 kPa
VBN2E13S0C 1 1/2 in. DN40 172 Cv 148 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac None 100 psi 689 kPa

Indoor Air Quality


VBN2E13S0D 1 1/2 in. DN40 172 Cv 148 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating None 100 psi 689 kPa
VBN2E13S0X 1 1/2 in. DN40 172 Cv 148 kvs 316 stainless steel 316 Stainless Steel No pre-assembled actuator None 100 psi 689 kPa
VBN2FT3PRA 2 in. DN50 108 Cv 93 kvs Nickel-plated brass ball Brass Non-Spring Return Floating NEMA 3R 100 psi 689 kPa
VBN2FT3PRB 2 in. DN50 108 Cv 93 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa
VBN2FT3PRC 2 in. DN50 108 Cv 93 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa
VBN2FT3PRD 2 in. DN50 108 Cv 93 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa
VBN2FT3SRA 2 in. DN50 108 Cv 93 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating NEMA 3R 100 psi 689 kPa

Combustion Controls
VBN2FT3SRB 2 in. DN50 108 Cv 93 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa
VBN2FT3SRC 2 in. DN50 108 Cv 93 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa

Residential
VBN2FT3SRD 2 in. DN50 108 Cv 93 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa
VBN2FT3P0A 2 in. DN50 108 Cv 93 kvs Nickel-plated brass ball Brass Non-Spring Return Floating None 100 psi 689 kPa
VBN2FT3P0B 2 in. DN50 108 Cv 93 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating None 100 psi 689 kPa
VBN2FT3P0C 2 in. DN50 108 Cv 93 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac None 100 psi 689 kPa
VBN2FT3P0D 2 in. DN50 108 Cv 93 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating None 100 psi 689 kPa
VBN2FT3P0X 2 in. DN50 108 Cv 93 kvs Nickel-plated brass ball Brass No pre-assembled actuator None 100 psi 689 kPa

Hydronic Controls
VBN2FT3S0A 2 in. DN50 108 Cv 93 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating None 100 psi 689 kPa
VBN2FT3S0B 2 in. DN50 108 Cv 93 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating None 100 psi 689 kPa
VBN2FT3S0C 2 in. DN50 108 Cv 93 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac None 100 psi 689 kPa
VBN2FT3S0D 2 in. DN50 108 Cv 93 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating None 100 psi 689 kPa
VBN2FT3S0X 2 in. DN50 108 Cv 93 kvs 316 stainless steel 316 Stainless Steel No pre-assembled actuator None 100 psi 689 kPa
VBN2F23PRA 2 in. DN50 266 Cv 229 kvs Nickel-plated brass ball Brass Non-Spring Return Floating NEMA 3R 100 psi 689 kPa
VBN2F23PRB 2 in. DN50 266 Cv 229 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa
VBN2F23PRC 2 in. DN50 266 Cv 229 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa
VBN2F23PRD 2 in. DN50 266 Cv 229 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa

Controls
Water
VBN2F23SRA 2 in. DN50 266 Cv 229 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating NEMA 3R 100 psi 689 kPa
VBN2F23SRB 2 in. DN50 266 Cv 229 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa
VBN2F23SRC 2 in. DN50 266 Cv 229 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa
VBN2F23SRD 2 in. DN50 266 Cv 229 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa
VBN2F23P0A 2 in. DN50 266 Cv 229 kvs Nickel-plated brass ball Brass Non-Spring Return Floating None 100 psi 689 kPa
VBN2F23P0B 2 in. DN50 266 Cv 229 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating None 100 psi 689 kPa

Building Automation
VBN2F23P0C 2 in. DN50 266 Cv 229 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac None 100 psi 689 kPa
VBN2F23P0D 2 in. DN50 266 Cv 229 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating None 100 psi 689 kPa
VBN2F23P0X 2 in. DN50 266 Cv 229 kvs Nickel-plated brass ball Brass No pre-assembled actuator None 100 psi 689 kPa
VBN2F23S0A 2 in. DN50 266 Cv 229 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating None 100 psi 689 kPa
VBN2F23S0B 2 in. DN50 266 Cv 229 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating None 100 psi 689 kPa
VBN2F23S0C 2 in. DN50 266 Cv 229 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac None 100 psi 689 kPa
VBN2F23S0D 2 in. DN50 266 Cv 229 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating None 100 psi 689 kPa
VBN2F23S0X 2 in. DN50 266 Cv 229 kvs 316 stainless steel 316 Stainless Steel No pre-assembled actuator None 100 psi 689 kPa

Components
VBN2G13PRA 2 1/2 in. DN65 202 Cv 174 kvs Nickel-plated brass ball Brass Non-Spring Return Floating NEMA 3R 100 psi 689 kPa

Commercial
VBN2G13PRB 2 1/2 in. DN65 202 Cv 174 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa
VBN2G13PRC 2 1/2 in. DN65 202 Cv 174 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa
VBN2G13PRD 2 1/2 in. DN65 202 Cv 174 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa
VBN2G13SRA 2 1/2 in. DN65 202 Cv 174 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating NEMA 3R 100 psi 689 kPa
VBN2G13SRB 2 1/2 in. DN65 202 Cv 174 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa
VBN2G13SRC 2 1/2 in. DN65 202 Cv 174 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa
Pneumatic Controls

VBN2G13SRD 2 1/2 in. DN65 202 Cv 174 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa
VBN2G13P0A 2 1/2 in. DN65 202 Cv 174 kvs Nickel-plated brass ball Brass Non-Spring Return Floating None 100 psi 689 kPa
VBN2G13P0B 2 1/2 in. DN65 202 Cv 174 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating None 100 psi 689 kPa
VBN2G13P0C 2 1/2 in. DN65 202 Cv 174 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac None 100 psi 689 kPa
VBN2G13P0D 2 1/2 in. DN65 202 Cv 174 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating None 100 psi 689 kPa
VBN2G13P0X 2 1/2 in. DN65 202 Cv 174 kvs Nickel-plated brass ball Brass No pre-assembled actuator None 100 psi 689 kPa
VBN2G13S0A 2 1/2 in. DN65 202 Cv 174 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating None 100 psi 689 kPa
Industrial Combustion

VBN2G13S0B 2 1/2 in. DN65 202 Cv 174 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating None 100 psi 689 kPa
VBN2G13S0C 2 1/2 in. DN65 202 Cv 174 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac None 100 psi 689 kPa
Controls

VBN2G13S0D 2 1/2 in. DN65 202 Cv 174 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating None 100 psi 689 kPa
VBN2G13S0X 2 1/2 in. DN65 202 Cv 174 kvs 316 stainless steel 316 Stainless Steel No pre-assembled actuator None 100 psi 689 kPa

70-6910 591
Control Ball Valves
Maximum
Close-off
Weather
Valve Size Flow Capacity Materials Pressure
Enclo-
Product Number (inch) DN (Cv) (Kv) (Plug/Ball/Disc) (Stem) Actuation sure (psi) (kPa)
VBN2HU3PRA 3 in. DN80 145 Cv 125 kvs Nickel-plated brass ball Brass Non-Spring Return Floating NEMA 3R 100 psi 689 kPa
VBN2HU3PRB 3 in. DN80 145 Cv 125 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa
VBN2HU3PRC 3 in. DN80 145 Cv 125 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa
VBN2HU3PRD 3 in. DN80 145 Cv 125 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa
VBN2HU3SRA 3 in. DN80 145 Cv 125 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating NEMA 3R 100 psi 689 kPa
VBN2HU3SRB 3 in. DN80 145 Cv 125 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating NEMA 3R 100 psi 689 kPa
VBN2HU3SRC 3 in. DN80 145 Cv 125 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac NEMA 3R 100 psi 689 kPa
VBN2HU3SRD 3 in. DN80 145 Cv 125 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating NEMA 3R 100 psi 689 kPa
VBN2HU3P0A 3 in. DN80 145 Cv 125 kvs Nickel-plated brass ball Brass Non-Spring Return Floating None 100 psi 689 kPa
VBN2HU3P0B 3 in. DN80 145 Cv 125 kvs Nickel-plated brass ball Brass Non-Spring Return Modulating None 100 psi 689 kPa
VBN2HU3P0C 3 in. DN80 145 Cv 125 kvs Nickel-plated brass ball Brass Spring Return 2-Position, 24Vac None 100 psi 689 kPa
VBN2HU3P0D 3 in. DN80 145 Cv 125 kvs Nickel-plated brass ball Brass Spring Return Floating/Modulating None 100 psi 689 kPa
VBN2HU3P0X 3 in. DN80 145 Cv 125 kvs Nickel-plated brass ball Brass No pre-assembled actuator None 100 psi 689 kPa
VBN2HU3S0A 3 in. DN80 145 Cv 125 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Floating None 100 psi 689 kPa
VBN2HU3S0B 3 in. DN80 145 Cv 125 kvs 316 stainless steel 316 Stainless Steel Non-Spring Return Modulating None 100 psi 689 kPa
VBN2HU3S0C 3 in. DN80 145 Cv 125 kvs 316 stainless steel 316 Stainless Steel Spring Return 2-Position, 24Vac None 100 psi 689 kPa
VBN2HU3S0D 3 in. DN80 145 Cv 125 kvs 316 stainless steel 316 Stainless Steel Spring Return Floating/Modulating None 100 psi 689 kPa
VBN2HU3S0X 3 in. DN80 145 Cv 125 kvs 316 stainless steel 316 Stainless Steel No pre-assembled actuator None 100 psi 689 kPa

592 customer.honeywell.com 70-6910


Control Ball Valves
VBN3 Three-way Threaded Control Ball Valve

Controls
Home
The VBN3 Three-Way Control Ball Valves control hot and chilled
water with glycol solutions up to 50% in heating, ventilating, and
air conditioning (HVAC) systems to provide two-position or
modulating functions. These valve assemblies can be ordered with
or without factory-mounted non-spring return or spring return
direct-coupled actuators (DCA).
• Sizes from 1/2 to 2-1/2 inches with internal (female) NPT

Indoor Air Quality


connections.
• Equal percentage or linear flow characteristics.
• Reduced B-port Cv for constant loop flow.
• Choice of four, factory-installed actuation control schemes: Floating,
Modulating (2-10 V), Spring Return 2-Position, Spring Return
Modulating/Floating.
• Field configurable for normally open or normally
• closed fail-safe position.
• Removable manual operating handle to control valve during

Combustion Controls
installation or in an event of power failure.
• ANSI Class IV seat leakage specification (0.01% of Cv).

Residential
• Optional NEMA 3R (IP54) rated enclosure for outdoor applications.
• Actuator can be mounted on the valve in any of four positions.
• Wide Cv choices from 0.33 to 109.
• Valve installs in a globe valve "T" pattern, no extra elbows or piping
required.
• Field-serviceable stem assembly.
• Nickel-chrome plated brass ball and stem.
• Mixing or Diverting control.

Hydronic Controls
Valve Type: Control Ball Valve Fluid Temperature Range: -22 F to +250 F (-30 C to +121 F)
Body Pattern: Three-way
Materials
Flow Characteristic: Linear (B-AB); Equal Percentage (A-AB) (Body): Brass
Connection Type: Female NPT (Stem): Brass
Controlled Fluid: Chilled or hot water with up to 50% Glycol. Not for (Seat): Teflon® seals with EPDM O-rings
use with steam or fuels. (Plug/Ball/Disc): Nickel-plated brass ball
Leakage Rating: ANSI Class IV (0.01% of Cv maximum) (Flow Control Insert) : Noryl®
Maximum Safe Operating Pressure: 360 psi (2482 kPa)
Dimensions in inches (millimeters)

Controls
Water
F

Building Automation
B
E D

A
C

Pipe Model CV Dimensions inches (mm) Weight


Size No. A B C D E F G lb (kg)

Components
Commercial
1/2" VBN3A 0.33, 0.59, 1.0, 2.4, 4.3, 8.0 3-1/2 (90) 3-5/16 (84) 7 (178) 3 (76) 4 (102) 9-3/8 (238) 2-3/8 (60) 2.4 (1.1)
3/4" VBN3B 0.40, 0.66, 1.3, 2.4, 3.8, 11.0 2-13/16 (71) 3-5/16 (84) 6-1/2 (168) 3 (76) 4 (102) 8-13/16 (224) 2 (51) 2 (0.9)
1" VBN3C 0.40, 0.65, 1.3, 2.3, 3.5 3-13/16 (97) 3-5/16 (84) 7-5/16 (186) 3 (76) 4 (102) 9-1/2 (241) 2-3/4 (70) 2.8 (1.3)
8.6, 22 3 (76) 3-13/16 6-13/16 (173) 3 (76) 4 (102) 9-13/16 (249) 2-5/8 (67) 2.6 (1.2)
4.5, 14.9, 31 4-1/2 (114) 4 (102) 7-13/16 (198) 3 (76) 4 (102) 10-13/16 (275) 3-1/4 (83) 3.3 (1.5)
1-1/4" VBN3D 4.1, 8.7, 19.0 3 (76) 3-13/16 6-13/16 (173) 3 (76) 4 (102) 9-13/16 (249) 2-1/2 (64) 2.5 (1.1)
12.7, 27, 34 3-5/8 (92) 4 (102) 7-5/16 (186) 3 (76) 4 (102) 10-5/16 (262) 2-3/4 (70) 2.8 (1.3)
Pneumatic Controls

1-1/2" VBN3E 4.0, 8.3, 13.4, 32 4-1/2 (114) 4 (102) 7-13/16 (198) 3 (76) 4 (102) 10-13/16 (275) 3-1/4 (83) 3.3 (1.5)
24, 61 4 (102) 4-1/2 (114) 7-5/16 (186) 3 (76) 4 (102) 11 (279) 3-1/4 (83) 3.3 (1.5)
2" VBN3F 24, 38, 57 4 (102) 4-1/2 (114) 7-5/16 (186) 3 (76) 4 (102) 11 (279) 3-1/4 (83) 3.3 (1.5)
83, 109 5 (127) 5-13/16 7-13/16 (198) 3 (76) 4 (102) 12-5/16 (313) 3-3/4 (95) 3.8 (1.7)
2-1/2" VBN3G 38, 74, 100 5 (127) 5-13/16 7-13/16 (198) 3 (76) 4 (102) 12-5/16 (313) 3-3/4 (95) 3.8 (1.7)

M13730
Industrial Combustion
Controls

70-6910 593
Control Ball Valves
Maximum Close-
Valve Size Flow Capacity off Pressure
Weather
Product Number (inch) DN (Cv) (Kv) Actuation Enclosure (psi) (kPa)
VBN3AB3PRA 1/2 in. DN15 0.33 Cv 0.28 kvs Non-Spring Return Floating NEMA 3R 50 psi 345 kPa
VBN3AB3PRB 1/2 in. DN15 0.33 Cv 0.28 kvs Non-Spring Return Modulating NEMA 3R 50 psi 345 kPa
VBN3AB3PRC 1/2 in. DN15 0.33 Cv 0.28 kvs Spring Return 2-Position, 24Vac NEMA 3R 50 psi 345 kPa
VBN3AB3PRD 1/2 in. DN15 0.33 Cv 0.28 kvs Spring Return Floating/Modulating NEMA 3R 50 psi 345 kPa
VBN3AB3P0A 1/2 in. DN15 0.33 Cv 0.28 kvs Non-Spring Return Floating None 50 psi 345 kPa
VBN3AB3P0B 1/2 in. DN15 0.33 Cv 0.28 kvs Non-Spring Return Modulating None 50 psi 345 kPa
VBN3AB3P0C 1/2 in. DN15 0.33 Cv 0.28 kvs Spring Return 2-Position, 24Vac None 50 psi 345 kPa
VBN3AB3P0D 1/2 in. DN15 0.33 Cv 0.28 kvs Spring Return Floating/Modulating None 50 psi 345 kPa
VBN3AB3P0X 1/2 in. DN15 0.33 Cv 0.28 kvs No pre-assembled actuator None 50 psi 345 kPa
VBN3AC3PRA 1/2 in. DN15 0.59 Cv 0.5 kvs Non-Spring Return Floating NEMA 3R 50 psi 345 kPa
VBN3AC3PRB 1/2 in. DN15 0.59 Cv 0.5 kvs Non-Spring Return Modulating NEMA 3R 50 psi 345 kPa
VBN3AC3PRC 1/2 in. DN15 0.59 Cv 0.5 kvs Spring Return 2-Position, 24Vac NEMA 3R 50 psi 345 kPa
VBN3AC3PRD 1/2 in. DN15 0.59 Cv 0.5 kvs Spring Return Floating/Modulating NEMA 3R 50 psi 345 kPa
VBN3AC3P0A 1/2 in. DN15 0.59 Cv 0.5 kvs Non-Spring Return Floating None 50 psi 345 kPa
VBN3AC3P0B 1/2 in. DN15 0.59 Cv 0.5 kvs Non-Spring Return Modulating None 50 psi 345 kPa
VBN3AC3P0C 1/2 in. DN15 0.59 Cv 0.5 kvs Spring Return 2-Position, 24Vac None 50 psi 345 kPa
VBN3AC3P0D 1/2 in. DN15 0.59 Cv 0.5 kvs Spring Return Floating/Modulating None 50 psi 345 kPa
VBN3AC3P0X 1/2 in. DN15 0.59 Cv 0.5 kvs No pre-assembled actuator None 50 psi 345 kPa
VBN3AE3PRA 1/2 in. DN15 1.0 Cv 0.86 kvs Non-Spring Return Floating NEMA 3R 50 psi 345 kPa
VBN3AE3PRB 1/2 in. DN15 1.0 Cv 0.86 kvs Non-Spring Return Modulating NEMA 3R 50 psi 345 kPa
VBN3AE3PRC 1/2 in. DN15 1.0 Cv 0.86 kvs Spring Return 2-Position, 24Vac NEMA 3R 50 psi 345 kPa
VBN3AE3PRD 1/2 in. DN15 1.0 Cv 0.86 kvs Spring Return Floating/Modulating NEMA 3R 50 psi 345 kPa
VBN3AE3P0A 1/2 in. DN15 1.0 Cv 0.86 kvs Non-Spring Return Floating None 50 psi 345 kPa
VBN3AE3P0B 1/2 in. DN15 1.0 Cv 0.86 kvs Non-Spring Return Modulating None 50 psi 345 kPa
VBN3AE3P0C 1/2 in. DN15 1.0 Cv 0.86 kvs Spring Return 2-Position, 24Vac None 50 psi 345 kPa
VBN3AE3P0D 1/2 in. DN15 1.0 Cv 0.86 kvs Spring Return Floating/Modulating None 50 psi 345 kPa
VBN3AE3P0X 1/2 in. DN15 1.0 Cv 0.86 kvs No pre-assembled actuator None 50 psi 345 kPa
VBN3AF3PRA 1/2 in. DN15 2.4 Cv 2.1 kvs Non-Spring Return Floating NEMA 3R 50 psi 345 kPa
VBN3AF3PRB 1/2 in. DN15 2.4 Cv 2.1 kvs Non-Spring Return Modulating NEMA 3R 50 psi 345 kPa
VBN3AF3PRC 1/2 in. DN15 2.4 Cv 2.1 kvs Spring Return 2-Position, 24Vac NEMA 3R 50 psi 345 kPa
VBN3AF3PRD 1/2 in. DN15 2.4 Cv 2.1 kvs Spring Return Floating/Modulating NEMA 3R 50 psi 345 kPa
VBN3AF3P0A 1/2 in. DN15 2.4 Cv 2.1 kvs Non-Spring Return Floating None 50 psi 345 kPa
VBN3AF3P0B 1/2 in. DN15 2.4 Cv 2.1 kvs Non-Spring Return Modulating None 50 psi 345 kPa
VBN3AF3P0C 1/2 in. DN15 2.4 Cv 2.1 kvs Spring Return 2-Position, 24Vac None 50 psi 345 kPa
VBN3AF3P0D 1/2 in. DN15 2.4 Cv 2.1 kvs Spring Return Floating/Modulating None 50 psi 345 kPa
VBN3AF3P0X 1/2 in. DN15 2.4 Cv 2.1 kvs No pre-assembled actuator None 50 psi 345 kPa
VBN3AH3PRA 1/2 in. DN15 4.3 Cv 3.7 kvs Non-Spring Return Floating NEMA 3R 50 psi 345 kPa
VBN3AH3PRB 1/2 in. DN15 4.3 Cv 3.7 kvs Non-Spring Return Modulating NEMA 3R 50 psi 345 kPa
VBN3AH3PRC 1/2 in. DN15 4.3 Cv 3.7 kvs Spring Return 2-Position, 24Vac NEMA 3R 50 psi 345 kPa
VBN3AH3PRD 1/2 in. DN15 4.3 Cv 3.7 kvs Spring Return Floating/Modulating NEMA 3R 50 psi 345 kPa
VBN3AH3P0A 1/2 in. DN15 4.3 Cv 3.7 kvs Non-Spring Return Floating None 50 psi 345 kPa
VBN3AH3P0B 1/2 in. DN15 4.3 Cv 3.7 kvs Non-Spring Return Modulating None 50 psi 345 kPa
VBN3AH3P0C 1/2 in. DN15 4.3 Cv 3.7 kvs Spring Return 2-Position, 24Vac None 50 psi 345 kPa
VBN3AH3P0D 1/2 in. DN15 4.3 Cv 3.7 kvs Spring Return Floating/Modulating None 50 psi 345 kPa
VBN3AH3P0X 1/2 in. DN15 4.3 Cv 3.7 kvs No pre-assembled actuator None 50 psi 345 kPa
VBN3AJ3PRA 1/2 in. DN15 8.0 Cv 6.9 kvs Non-Spring Return Floating NEMA 3R 50 psi 345 kPa
VBN3AJ3PRB 1/2 in. DN15 8.0 Cv 6.9 kvs Non-Spring Return Modulating NEMA 3R 50 psi 345 kPa
VBN3AJ3PRC 1/2 in. DN15 8.0 Cv 6.9 kvs Spring Return 2-Position, 24Vac NEMA 3R 50 psi 345 kPa
VBN3AJ3PRD 1/2 in. DN15 8.0 Cv 6.9 kvs Spring Return Floating/Modulating NEMA 3R 50 psi 345 kPa
VBN3AJ3P0A 1/2 in. DN15 8.0 Cv 6.9 kvs Non-Spring Return Floating None 50 psi 345 kPa
VBN3AJ3P0B 1/2 in. DN15 8.0 Cv 6.9 kvs Non-Spring Return Modulating None 50 psi 345 kPa
VBN3AJ3P0C 1/2 in. DN15 8.0 Cv 6.9 kvs Spring Return 2-Position, 24Vac None 50 psi 345 kPa
VBN3AJ3P0D 1/2 in. DN15 8.0 Cv 6.9 kvs Spring Return Floating/Modulating None 50 psi 345 kPa
VBN3AJ3P0X 1/2 in. DN15 8.0 Cv 6.9 kvs No pre-assembled actuator None 50 psi 345 kPa
VBN3BC3PRA 3/4 in. DN20 0.40 Cv 0.34 kvs Non-Spring Return Floating NEMA 3R 50 psi 345 kPa
VBN3BC3PRB 3/4 in. DN20 0.40 Cv 0.34 kvs Non-Spring Return Modulating NEMA 3R 50 psi 345 kPa

594 customer.honeywell.com 70-6910


Control Ball Valves

Controls
Maximum Close-

Home
Valve Size Flow Capacity off Pressure
Weather
Product Number (inch) DN (Cv) (Kv) Actuation Enclosure (psi) (kPa)
VBN3BC3PRC 3/4 in. DN20 0.40 Cv 0.34 kvs Spring Return 2-Position, 24Vac NEMA 3R 50 psi 345 kPa
VBN3BC3PRD 3/4 in. DN20 0.40 Cv 0.34 kvs Spring Return Floating/Modulating NEMA 3R 50 psi 345 kPa
VBN3BC3P0A 3/4 in. DN20 0.40 Cv 0.34 kvs Non-Spring Return Floating None 50 psi 345 kPa

Indoor Air Quality


VBN3BC3P0B 3/4 in. DN20 0.40 Cv 0.34 kvs Non-Spring Return Modulating None 50 psi 345 kPa
VBN3BC3P0C 3/4 in. DN20 0.40 Cv 0.34 kvs Spring Return 2-Position, 24Vac None 50 psi 345 kPa
VBN3BC3P0D 3/4 in. DN20 0.40 Cv 0.34 kvs Spring Return Floating/Modulating None 50 psi 345 kPa
VBN3BC3P0X 3/4 in. DN20 0.40 Cv 0.34 kvs No pre-assembled actuator None 50 psi 345 kPa
VBN3BD3PRA 3/4 in. DN20 0.66 Cv 0.57 kvs Non-Spring Return Floating NEMA 3R 50 psi 345 kPa
VBN3BD3PRB 3/4 in. DN20 0.66 Cv 0.57 kvs Non-Spring Return Modulating NEMA 3R 50 psi 345 kPa
VBN3BD3PRC 3/4 in. DN20 0.66 Cv 0.57 kvs Spring Return 2-Position, 24Vac NEMA 3R 50 psi 345 kPa

Combustion Controls
VBN3BD3PRD 3/4 in. DN20 0.66 Cv 0.57 kvs Spring Return Floating/Modulating NEMA 3R 50 psi 345 kPa
VBN3BD3P0A 3/4 in. DN20 0.66 Cv 0.57 kvs Non-Spring Return Floating None 50 psi 345 kPa

Residential
VBN3BD3P0B 3/4 in. DN20 0.66 Cv 0.57 kvs Non-Spring Return Modulating None 50 psi 345 kPa
VBN3BD3P0C 3/4 in. DN20 0.66 Cv 0.57 kvs Spring Return 2-Position, 24Vac None 50 psi 345 kPa
VBN3BD3P0D 3/4 in. DN20 0.66 Cv 0.57 kvs Spring Return Floating/Modulating None 50 psi 345 kPa
VBN3BD3P0X 3/4 in. DN20 0.66 Cv 0.57 kvs No pre-assembled actuator None 50 psi 345 kPa
VBN3BE3PRA 3/4 in. DN20 1.3 Cv 1.1 kvs Non-Spring Return Floating NEMA 3R 50 psi 345 kPa
VBN3BE3PRB 3/4 in. DN20 1.3 Cv 1.1 kvs Non-Spring Return Modulating NEMA 3R 50 psi 345 kPa

Hydronic Controls
VBN3BE3PRC 3/4 in. DN20 1.3 Cv 1.1 kvs Spring Return 2-Position, 24Vac NEMA 3R 50 psi 345 kPa
VBN3BE3PRD 3/4 in. DN20 1.3 Cv 1.1 kvs Spring Return Floating/Modulating NEMA 3R 50 psi 345 kPa
VBN3BE3P0A 3/4 in. DN20 1.3 Cv 1.1 kvs Non-Spring Return Floating None 50 psi 345 kPa
VBN3BE3P0B 3/4 in. DN20 1.3 Cv 1.1 kvs Non-Spring Return Modulating None 50 psi 345 kPa
VBN3BE3P0C 3/4 in. DN20 1.3 Cv 1.1 kvs Spring Return 2-Position, 24Vac None 50 psi 345 kPa
VBN3BE3P0D 3/4 in. DN20 1.3 Cv 1.1 kvs Spring Return Floating/Modulating None 50 psi 345 kPa
VBN3BE3P0X 3/4 in. DN20 1.3 Cv 1.1 kvs No pre-assembled actuator None 50 psi 345 kPa
VBN3BF3PRA 3/4 in. DN20 2.4 Cv 2.1 kvs Non-Spring Return Floating NEMA 3R 50 psi 345 kPa

Controls
VBN3BF3PRB 3/4 in. DN20 2.4 Cv 2.1 kvs Non-Spring Return Modulating NEMA 3R 50 psi 345 kPa

Water
VBN3BF3PRC 3/4 in. DN20 2.4 Cv 2.1 kvs Spring Return 2-Position, 24Vac NEMA 3R 50 psi 345 kPa
VBN3BF3PRD 3/4 in. DN20 2.4 Cv 2.1 kvs Spring Return Floating/Modulating NEMA 3R 50 psi 345 kPa
VBN3BF3P0A 3/4 in. DN20 2.4 Cv 2.1 kvs Non-Spring Return Floating None 50 psi 345 kPa
VBN3BF3P0B 3/4 in. DN20 2.4 Cv 2.1 kvs Non-Spring Return Modulating None 50 psi 345 kPa
VBN3BF3P0C 3/4 in. DN20 2.4 Cv 2.1 kvs Spring Return 2-Position, 24Vac None 50 psi 345 kPa

Building Automation
VBN3BF3P0D 3/4 in. DN20 2.4 Cv 2.1 kvs Spring Return Floating/Modulating None 50 psi 345 kPa
VBN3BF3P0X 3/4 in. DN20 2.4 Cv 2.1 kvs No pre-assembled actuator None 50 psi 345 kPa
VBN3BG3PRA 3/4 in. DN20 3.8 Cv 3.3 kvs Non-Spring Return Floating NEMA 3R 50 psi 345 kPa
VBN3BG3PRB 3/4 in. DN20 3.8 Cv 3.3 kvs Non-Spring Return Modulating NEMA 3R 50 psi 345 kPa
VBN3BG3PRC 3/4 in. DN20 3.8 Cv 3.3 kvs Spring Return 2-Position, 24Vac NEMA 3R 50 psi 345 kPa
VBN3BG3PRD 3/4 in. DN20 3.8 Cv 3.3 kvs Spring Return Floating/Modulating NEMA 3R 50 psi 345 kPa
VBN3BG3P0A 3/4 in. DN20 3.8 Cv 3.3 kvs Non-Spring Return Floating None 50 psi 345 kPa
VBN3BG3P0B 3/4 in. DN20 3.8 Cv 3.3 kvs Non-Spring Return Modulating None 50 psi 345 kPa

Components
Commercial
VBN3BG3P0C 3/4 in. DN20 3.8 Cv 3.3 kvs Spring Return 2-Position, 24Vac None 50 psi 345 kPa
VBN3BG3P0D 3/4 in. DN20 3.8 Cv 3.3 kvs Spring Return Floating/Modulating None 50 psi 345 kPa
VBN3BG3P0X 3/4 in. DN20 3.8 Cv 3.3 kvs No pre-assembled actuator None 50 psi 345 kPa
VBN3BJ3PRA 3/4 in. DN20 7.0 Cv 6.5 kvs Non-Spring Return Floating NEMA 3R 50 psi 345 kPa
VBN3BJ3PRB 3/4 in. DN20 7.0 Cv 6.5 kvs Non-Spring Return Modulating NEMA 3R 50 psi 345 kPa
VBN3BJ3PRC 3/4 in. DN20 7.0 Cv 6.5 kvs Spring Return 2-Position, 24Vac NEMA 3R 50 psi 345 kPa
Pneumatic Controls

VBN3BJ3PRD 3/4 in. DN20 7.0 Cv 6.5 kvs Spring Return Floating/Modulating NEMA 3R 50 psi 345 kPa
VBN3BJ3P0A 3/4 in. DN20 7.0 Cv 6.5 kvs Non-Spring Return Floating None 50 psi 345 kPa
VBN3BJ3P0B 3/4 in. DN20 7.0 Cv 6.5 kvs Non-Spring Return Modulating None 50 psi 345 kPa
VBN3BJ3P0C 3/4 in. DN20 7.0 Cv 6.5 kvs Spring Return 2-Position, 24Vac None 50 psi 345 kPa
VBN3BJ3P0D 3/4 in. DN20 7.0 Cv 6.5 kvs Spring Return Floating/Modulating None 50 psi 345 kPa
VBN3BJ3P0X 3/4 in. DN20 7.0 Cv 6.5 kvs No pre-assembled actuator None 50 psi 345 kPa
VBN3BK3PRA 3/4 in. DN20 11.0 Cv 9.5 kvs Non-Spring Return Floating NEMA 3R 50 psi 345 kPa
Industrial Combustion

VBN3BK3PRB 3/4 in. DN20 11.0 Cv 9.5 kvs Non-Spring Return Modulating NEMA 3R 50 psi 345 kPa
VBN3BK3PRC 3/4 in. DN20 11.0 Cv 9.5 kvs Spring Return 2-Position, 24Vac NEMA 3R 50 psi 345 kPa
Controls

VBN3BK3PRD 3/4 in. DN20 11.0 Cv 9.5 kvs Spring Return Floating/Modulating NEMA 3R 50 psi 345 kPa
VBN3BK3P0A 3/4 in. DN20 11.0 Cv 9.5 kvs Non-Spring Return Floating None 50 psi 345 kPa

70-6910 595
Control Ball Valves
Maximum Close-
Valve Size Flow Capacity off Pressure
Weather
Product Number (inch) DN (Cv) (Kv) Actuation Enclosure (psi) (kPa)
VBN3BK3P0B 3/4 in. DN20 11.0 Cv 9.5 kvs Non-Spring Return Modulating None 50 psi 345 kPa
VBN3BK3P0C 3/4 in. DN20 11.0 Cv 9.5 kvs Spring Return 2-Position, 24Vac None 50 psi 345 kPa
VBN3BK3P0D 3/4 in. DN20 11.0 Cv 9.5 kvs Spring Return Floating/Modulating None 50 psi 345 kPa
VBN3BK3P0X 3/4 in. DN20 11.0 Cv 9.5 kvs No pre-assembled actuator None 50 psi 345 kPa
VBN3CC3PRA 1 in. DN25 0.40 Cv 0.34 kvs Non-Spring Return Floating NEMA 3R 50 psi 345 kPa
VBN3CC3PRB 1 in. DN25 0.40 Cv 0.34 kvs Non-Spring Return Modulating NEMA 3R 50 psi 345 kPa
VBN3CC3PRC 1 in. DN25 0.40 Cv 0.34 kvs Spring Return 2-Position, 24Vac NEMA 3R 50 psi 345 kPa
VBN3CC3PRD 1 in. DN25 0.40 Cv 0.34 kvs Spring Return Floating/Modulating NEMA 3R 50 psi 345 kPa
VBN3CC3P0A 1 in. DN25 0.40 Cv 0.34 kvs Non-Spring Return Floating None 50 psi 345 kPa
VBN3CC3P0B 1 in. DN25 0.40 Cv 0.34 kvs Non-Spring Return Modulating None 50 psi 345 kPa
VBN3CC3P0C 1 in. DN25 0.40 Cv 0.34 kvs Spring Return 2-Position, 24Vac None 50 psi 345 kPa
VBN3CC3P0D 1 in. DN25 0.40 Cv 0.34 kvs Spring Return Floating/Modulating None 50 psi 345 kPa
VBN3CC3P0X 1 in. DN25 0.40 Cv 0.34 kvs No pre-assembled actuator None 50 psi 345 kPa
VBN3CD3PRA 1 in. DN25 0.65 Cv 0.56 kvs Non-Spring Return Floating NEMA 3R 50 psi 345 kPa
VBN3CD3PRB 1 in. DN25 0.65 Cv 0.56 kvs Non-Spring Return Modulating NEMA 3R 50 psi 345 kPa
VBN3CD3PRC 1 in. DN25 0.65 Cv 0.56 kvs Spring Return 2-Position, 24Vac NEMA 3R 50 psi 345 kPa
VBN3CD3PRD 1 in. DN25 0.65 Cv 0.56 kvs Spring Return Floating/Modulating NEMA 3R 50 psi 345 kPa
VBN3CD3P0A 1 in. DN25 0.65 Cv 0.56 kvs Non-Spring Return Floating None 50 psi 345 kPa
VBN3CD3P0B 1 in. DN25 0.65 Cv 0.56 kvs Non-Spring Return Modulating None 50 psi 345 kPa
VBN3CD3P0C 1 in. DN25 0.65 Cv 0.56 kvs Spring Return 2-Position, 24Vac None 50 psi 345 kPa
VBN3CD3P0D 1 in. DN25 0.65 Cv 0.56 kvs Spring Return Floating/Modulating None 50 psi 345 kPa
VBN3CD3P0X 1 in. DN25 0.65 Cv 0.56 kvs No pre-assembled actuator None 50 psi 345 kPa
VBN3CE3PRA 1 in. DN25 1.3 Cv 1.1 kvs Non-Spring Return Floating NEMA 3R 50 psi 345 kPa
VBN3CE3PRB 1 in. DN25 1.3 Cv 1.1 kvs Non-Spring Return Modulating NEMA 3R 50 psi 345 kPa
VBN3CE3PRC 1 in. DN25 1.3 Cv 1.1 kvs Spring Return 2-Position, 24Vac NEMA 3R 50 psi 345 kPa
VBN3CE3PRD 1 in. DN25 1.3 Cv 1.1 kvs Spring Return Floating/Modulating NEMA 3R 50 psi 345 kPa
VBN3CE3P0A 1 in. DN25 1.3 Cv 1.1 kvs Non-Spring Return Floating None 50 psi 345 kPa
VBN3CE3P0B 1 in. DN25 1.3 Cv 1.1 kvs Non-Spring Return Modulating None 50 psi 345 kPa
VBN3CE3P0C 1 in. DN25 1.3 Cv 1.1 kvs Spring Return 2-Position, 24Vac None 50 psi 345 kPa
VBN3CE3P0D 1 in. DN25 1.3 Cv 1.1 kvs Spring Return Floating/Modulating None 50 psi 345 kPa
VBN3CE3P0X 1 in. DN25 1.3 Cv 1.1 kvs No pre-assembled actuator None 50 psi 345 kPa
VBN3CF3PRA 1 in. DN25 2.3 Cv 2.0 kvs Non-Spring Return Floating NEMA 3R 50 psi 345 kPa
VBN3CF3PRB 1 in. DN25 2.3 Cv 2.0 kvs Non-Spring Return Modulating NEMA 3R 50 psi 345 kPa
VBN3CF3PRC 1 in. DN25 2.3 Cv 2.0 kvs Spring Return 2-Position, 24Vac NEMA 3R 50 psi 345 kPa
VBN3CF3PRD 1 in. DN25 2.3 Cv 2.0 kvs Spring Return Floating/Modulating NEMA 3R 50 psi 345 kPa
VBN3CF3P0A 1 in. DN25 2.3 Cv 2.0 kvs Non-Spring Return Floating None 50 psi 345 kPa
VBN3CF3P0B 1 in. DN25 2.3 Cv 2.0 kvs Non-Spring Return Modulating None 50 psi 345 kPa
VBN3CF3P0C 1 in. DN25 2.3 Cv 2.0 kvs Spring Return 2-Position, 24Vac None 50 psi 345 kPa
VBN3CF3P0D 1 in. DN25 2.3 Cv 2.0 kvs Spring Return Floating/Modulating None 50 psi 345 kPa
VBN3CF3P0X 1 in. DN25 2.3 Cv 2.0 kvs No pre-assembled actuator None 50 psi 345 kPa
VBN3CG3PRA 1 in. DN25 3.5 Cv 3.0 kvs Non-Spring Return Floating NEMA 3R 50 psi 345 kPa
VBN3CG3PRB 1 in. DN25 3.5 Cv 3.0 kvs Non-Spring Return Modulating NEMA 3R 50 psi 345 kPa
VBN3CG3PRC 1 in. DN25 3.5 Cv 3.0 kvs Spring Return 2-Position, 24Vac NEMA 3R 50 psi 345 kPa
VBN3CG3PRD 1 in. DN25 3.5 Cv 3.0 kvs Spring Return Floating/Modulating NEMA 3R 50 psi 345 kPa
VBN3CG3P0A 1 in. DN25 3.5 Cv 3.0 kvs Non-Spring Return Floating None 50 psi 345 kPa
VBN3CG3P0B 1 in. DN25 3.5 Cv 3.0 kvs Non-Spring Return Modulating None 50 psi 345 kPa
VBN3CG3P0C 1 in. DN25 3.5 Cv 3.0 kvs Spring Return 2-Position, 24Vac None 50 psi 345 kPa
VBN3CG3P0D 1 in. DN25 3.5 Cv 3.0 kvs Spring Return Floating/Modulating None 50 psi 345 kPa
VBN3CG3P0X 1 in. DN25 3.5 Cv 3.0 kvs No pre-assembled actuator None 50 psi 345 kPa
VBN3CH3PRA 1 in. DN25 4.5 Cv 3.9 kvs Non-Spring Return Floating NEMA 3R 50 psi 345 kPa
VBN3CH3PRB 1 in. DN25 4.5 Cv 3.9 kvs Non-Spring Return Modulating NEMA 3R 50 psi 345 kPa
VBN3CH3PRC 1 in. DN25 4.5 Cv 3.9 kvs Spring Return 2-Position, 24Vac NEMA 3R 50 psi 345 kPa
VBN3CH3PRD 1 in. DN25 4.5 Cv 3.9 kvs Spring Return Floating/Modulating NEMA 3R 50 psi 345 kPa
VBN3CH3P0A 1 in. DN25 4.5 Cv 3.9 kvs Non-Spring Return Floating None 50 psi 345 kPa
VBN3CH3P0B 1 in. DN25 4.5 Cv 3.9 kvs Non-Spring Return Modulating None 50 psi 345 kPa
VBN3CH3P0C 1 in. DN25 4.5 Cv 3.9 kvs Spring Return 2-Position, 24Vac None 50 psi 345 kPa
VBN3CH3P0D 1 in. DN25 4.5 Cv 3.9 kvs Spring Return Floating/Modulating None 50 psi 345 kPa

596 customer.honeywell.com 70-6910


Control Ball Valves

Controls
Maximum Close-

Home
Valve Size Flow Capacity off Pressure
Weather
Product Number (inch) DN (Cv) (Kv) Actuation Enclosure (psi) (kPa)
VBN3CH3P0X 1 in. DN25 4.5 Cv 3.9 kvs No pre-assembled actuator None 50 psi 345 kPa
VBN3CJ3PRA 1 in. DN25 8.6 Cv 7.4 kvs Non-Spring Return Floating NEMA 3R 50 psi 345 kPa
VBN3CJ3PRB 1 in. DN25 8.6 Cv 7.4 kvs Non-Spring Return Modulating NEMA 3R 50 psi 345 kPa

Indoor Air Quality


VBN3CJ3PRC 1 in. DN25 8.6 Cv 7.4 kvs Spring Return 2-Position, 24Vac NEMA 3R 50 psi 345 kPa
VBN3CJ3PRD 1 in. DN25 8.6 Cv 7.4 kvs Spring Return Floating/Modulating NEMA 3R 50 psi 345 kPa
VBN3CJ3P0A 1 in. DN25 8.6 Cv 7.4 kvs Non-Spring Return Floating None 50 psi 345 kPa
VBN3CJ3P0B 1 in. DN25 8.6 Cv 7.4 kvs Non-Spring Return Modulating None 50 psi 345 kPa
VBN3CJ3P0C 1 in. DN25 8.6 Cv 7.4 kvs Spring Return 2-Position, 24Vac None 50 psi 345 kPa
VBN3CJ3P0D 1 in. DN25 8.6 Cv 7.4 kvs Spring Return Floating/Modulating None 50 psi 345 kPa
VBN3CJ3P0X 1 in. DN25 8.6 Cv 7.4 kvs No pre-assembled actuator None 50 psi 345 kPa

Combustion Controls
VBN3CK3PRA 1 in. DN25 14.9 Cv 12.8 kvs Non-Spring Return Floating NEMA 3R 50 psi 345 kPa
VBN3CK3PRB 1 in. DN25 14.9 Cv 12.8 kvs Non-Spring Return Modulating NEMA 3R 50 psi 345 kPa

Residential
VBN3CK3PRC 1 in. DN25 14.9 Cv 12.8 kvs Spring Return 2-Position, 24Vac NEMA 3R 50 psi 345 kPa
VBN3CK3PRD 1 in. DN25 14.9 Cv 12.8 kvs Spring Return Floating/Modulating NEMA 3R 50 psi 345 kPa
VBN3CK3P0A 1 in. DN25 14.9 Cv 12.8 kvs Non-Spring Return Floating None 50 psi 345 kPa
VBN3CK3P0B 1 in. DN25 14.9 Cv 12.8 kvs Non-Spring Return Modulating None 50 psi 345 kPa
VBN3CK3P0C 1 in. DN25 14.9 Cv 12.8 kvs Spring Return 2-Position, 24Vac None 50 psi 345 kPa
VBN3CK3P0D 1 in. DN25 14.9 Cv 12.8 kvs Spring Return Floating/Modulating None 50 psi 345 kPa

Hydronic Controls
VBN3CK3P0X 1 in. DN25 14.9 Cv 12.8 kvs No pre-assembled actuator None 50 psi 345 kPa
VBN3CL3PRA 1 in. DN25 22 Cv 18.9 kvs Non-Spring Return Floating NEMA 3R 50 psi 345 kPa
VBN3CL3PRB 1 in. DN25 22 Cv 18.9 kvs Non-Spring Return Modulating NEMA 3R 50 psi 345 kPa
VBN3CL3PRC 1 in. DN25 22 Cv 18.9 kvs Spring Return 2-Position, 24Vac NEMA 3R 50 psi 345 kPa
VBN3CL3PRD 1 in. DN25 22 Cv 18.9 kvs Spring Return Floating/Modulating NEMA 3R 50 psi 345 kPa
VBN3CL3P0A 1 in. DN25 22 Cv 18.9 kvs Non-Spring Return Floating None 50 psi 345 kPa
VBN3CL3P0B 1 in. DN25 22 Cv 18.9 kvs Non-Spring Return Modulating None 50 psi 345 kPa
VBN3CL3P0C 1 in. DN25 22 Cv 18.9 kvs Spring Return 2-Position, 24Vac None 50 psi 345 kPa

Controls
VBN3CL3P0D 1 in. DN25 22 Cv 18.9 kvs Spring Return Floating/Modulating None 50 psi 345 kPa

Water
VBN3CL3P0X 1 in. DN25 22 Cv 18.9 kvs No pre-assembled actuator None 50 psi 345 kPa
VBN3CM3PRA 1 in. DN25 31 Cv 27 kvs Non-Spring Return Floating NEMA 3R 50 psi 345 kPa
VBN3CM3PRB 1 in. DN25 31 Cv 27 kvs Non-Spring Return Modulating NEMA 3R 50 psi 345 kPa
VBN3CM3PRC 1 in. DN25 31 Cv 27 kvs Spring Return 2-Position, 24Vac NEMA 3R 50 psi 345 kPa
VBN3CM3PRD 1 in. DN25 31 Cv 27 kvs Spring Return Floating/Modulating NEMA 3R 50 psi 345 kPa

Building Automation
VBN3CM3P0A 1 in. DN25 31 Cv 27 kvs Non-Spring Return Floating None 50 psi 345 kPa
VBN3CM3P0B 1 in. DN25 31 Cv 27 kvs Non-Spring Return Modulating None 50 psi 345 kPa
VBN3CM3P0C 1 in. DN25 31 Cv 27 kvs Spring Return 2-Position, 24Vac None 50 psi 345 kPa
VBN3CM3P0D 1 in. DN25 31 Cv 27 kvs Spring Return Floating/Modulating None 50 psi 345 kPa
VBN3CM3P0X 1 in. DN25 31 Cv 27 kvs No pre-assembled actuator None 50 psi 345 kPa
VBN3DH3PRA 1 1/4 in. DN32 4.1 Cv 3.5 kvs Non-Spring Return Floating NEMA 3R 40 psi 276 kPa
VBN3DH3PRB 1 1/4 in. DN32 4.1 Cv 3.5 kvs Non-Spring Return Modulating NEMA 3R 40 psi 276 kPa
VBN3DH3PRC 1 1/4 in. DN32 4.1 Cv 3.5 kvs Spring Return 2-Position, 24Vac NEMA 3R 40 psi 276 kPa

Components
Commercial
VBN3DH3PRD 1 1/4 in. DN32 4.1 Cv 3.5 kvs Spring Return Floating/Modulating NEMA 3R 40 psi 276 kPa
VBN3DH3P0A 1 1/4 in. DN32 4.1 Cv 3.5 kvs Non-Spring Return Floating None 40 psi 276 kPa
VBN3DH3P0B 1 1/4 in. DN32 4.1 Cv 3.5 kvs Non-Spring Return Modulating None 40 psi 276 kPa
VBN3DH3P0C 1 1/4 in. DN32 4.1 Cv 3.5 kvs Spring Return 2-Position, 24Vac None 40 psi 276 kPa
VBN3DH3P0D 1 1/4 in. DN32 4.1 Cv 3.5 kvs Spring Return Floating/Modulating None 40 psi 276 kPa
VBN3DH3P0X 1 1/4 in. DN32 4.1 Cv 3.5 kvs No pre-assembled actuator None 40 psi 276 kPa
Pneumatic Controls

VBN3DJ3PRA 1 1/4 in. DN32 8.7 Cv 7.5 kvs Non-Spring Return Floating NEMA 3R 40 psi 276 kPa
VBN3DJ3PRB 1 1/4 in. DN32 8.7 Cv 7.5 kvs Non-Spring Return Modulating NEMA 3R 40 psi 276 kPa
VBN3DJ3PRC 1 1/4 in. DN32 8.7 Cv 7.5 kvs Spring Return 2-Position, 24Vac NEMA 3R 40 psi 276 kPa
VBN3DJ3PRD 1 1/4 in. DN32 8.7 Cv 7.5 kvs Spring Return Floating/Modulating NEMA 3R 40 psi 276 kPa
VBN3DJ3P0A 1 1/4 in. DN32 8.7 Cv 7.5 kvs Non-Spring Return Floating None 40 psi 276 kPa
VBN3DJ3P0B 1 1/4 in. DN32 8.7 Cv 7.5 kvs Non-Spring Return Modulating None 40 psi 276 kPa
VBN3DJ3P0C 1 1/4 in. DN32 8.7 Cv 7.5 kvs Spring Return 2-Position, 24Vac None 40 psi 276 kPa
Industrial Combustion

VBN3DJ3P0D 1 1/4 in. DN32 8.7 Cv 7.5 kvs Spring Return Floating/Modulating None 40 psi 276 kPa
VBN3DJ3P0X 1 1/4 in. DN32 8.7 Cv 7.5 kvs No pre-assembled actuator None 40 psi 276 kPa
Controls

VBN3DK3PRA 1 1/4 in. DN32 12.7 Cv 10.9 kvs Non-Spring Return Floating NEMA 3R 40 psi 276 kPa
VBN3DK3PRB 1 1/4 in. DN32 12.7 Cv 10.9 kvs Non-Spring Return Modulating NEMA 3R 40 psi 276 kPa

70-6910 597
Control Ball Valves
Maximum Close-
Valve Size Flow Capacity off Pressure
Weather
Product Number (inch) DN (Cv) (Kv) Actuation Enclosure (psi) (kPa)
VBN3DK3PRC 1 1/4 in. DN32 12.7 Cv 10.9 kvs Spring Return 2-Position, 24Vac NEMA 3R 40 psi 276 kPa
VBN3DK3PRD 1 1/4 in. DN32 12.7 Cv 10.9 kvs Spring Return Floating/Modulating NEMA 3R 40 psi 276 kPa
VBN3DK3P0A 1 1/4 in. DN32 12.7 Cv 10.9 kvs Non-Spring Return Floating None 40 psi 276 kPa
VBN3DK3P0B 1 1/4 in. DN32 12.7 Cv 10.9 kvs Non-Spring Return Modulating None 40 psi 276 kPa
VBN3DK3P0C 1 1/4 in. DN32 12.7 Cv 10.9 kvs Spring Return 2-Position, 24Vac None 40 psi 276 kPa
VBN3DK3P0D 1 1/4 in. DN32 12.7 Cv 10.9 kvs Spring Return Floating/Modulating None 40 psi 276 kPa
VBN3DK3P0X 1 1/4 in. DN32 12.7 Cv 10.9 kvs No pre-assembled actuator None 40 psi 276 kPa
VBN3DL3PRA 1 1/4 in. DN32 19.4 Cv 16.7 kvs Non-Spring Return Floating NEMA 3R 40 psi 276 kPa
VBN3DL3PRB 1 1/4 in. DN32 19.4 Cv 16.7 kvs Non-Spring Return Modulating NEMA 3R 40 psi 276 kPa
VBN3DL3PRC 1 1/4 in. DN32 19.4 Cv 16.7 kvs Spring Return 2-Position, 24Vac NEMA 3R 40 psi 276 kPa
VBN3DL3PRD 1 1/4 in. DN32 19.4 Cv 16.7 kvs Spring Return Floating/Modulating NEMA 3R 40 psi 276 kPa
VBN3DL3P0A 1 1/4 in. DN32 19.4 Cv 16.7 kvs Non-Spring Return Floating None 40 psi 276 kPa
VBN3DL3P0B 1 1/4 in. DN32 19.4 Cv 16.7 kvs Non-Spring Return Modulating None 40 psi 276 kPa
VBN3DL3P0C 1 1/4 in. DN32 19.4 Cv 16.7 kvs Spring Return 2-Position, 24Vac None 40 psi 276 kPa
VBN3DL3P0D 1 1/4 in. DN32 19.4 Cv 16.7 kvs Spring Return Floating/Modulating None 40 psi 276 kPa
VBN3DL3P0X 1 1/4 in. DN32 19.4 Cv 16.7 kvs No pre-assembled actuator None 40 psi 276 kPa
VBN3DM3PRA 1 1/4 in. DN32 27 Cv 23 kvs Non-Spring Return Floating NEMA 3R 40 psi 276 kPa
VBN3DM3PRB 1 1/4 in. DN32 27 Cv 23 kvs Non-Spring Return Modulating NEMA 3R 40 psi 276 kPa
VBN3DM3PRC 1 1/4 in. DN32 27 Cv 23 kvs Spring Return 2-Position, 24Vac NEMA 3R 40 psi 276 kPa
VBN3DM3PRD 1 1/4 in. DN32 27 Cv 23 kvs Spring Return Floating/Modulating NEMA 3R 40 psi 276 kPa
VBN3DM3P0A 1 1/4 in. DN32 27 Cv 23 kvs Non-Spring Return Floating None 40 psi 276 kPa
VBN3DM3P0B 1 1/4 in. DN32 27 Cv 23 kvs Non-Spring Return Modulating None 40 psi 276 kPa
VBN3DM3P0C 1 1/4 in. DN32 27 Cv 23 kvs Spring Return 2-Position, 24Vac None 40 psi 276 kPa
VBN3DM3P0D 1 1/4 in. DN32 27 Cv 23 kvs Spring Return Floating/Modulating None 40 psi 276 kPa
VBN3DM3P0X 1 1/4 in. DN32 27 Cv 23 kvs No pre-assembled actuator None 40 psi 276 kPa
VBN3DN3PRA 1 1/4 in. DN32 34 Cv 29 kvs Non-Spring Return Floating NEMA 3R 40 psi 276 kPa
VBN3DN3PRB 1 1/4 in. DN32 34 Cv 29 kvs Non-Spring Return Modulating NEMA 3R 40 psi 276 kPa
VBN3DN3PRC 1 1/4 in. DN32 34 Cv 29 kvs Spring Return 2-Position, 24Vac NEMA 3R 40 psi 276 kPa
VBN3DN3PRD 1 1/4 in. DN32 34 Cv 29 kvs Spring Return Floating/Modulating NEMA 3R 40 psi 276 kPa
VBN3DN3P0A 1 1/4 in. DN32 34 Cv 29 kvs Non-Spring Return Floating None 40 psi 276 kPa
VBN3DN3P0B 1 1/4 in. DN32 34 Cv 29 kvs Non-Spring Return Modulating None 40 psi 276 kPa
VBN3DN3P0C 1 1/4 in. DN32 34 Cv 29 kvs Spring Return 2-Position, 24Vac None 40 psi 276 kPa
VBN3DN3P0D 1 1/4 in. DN32 34 Cv 29 kvs Spring Return Floating/Modulating None 40 psi 276 kPa
VBN3DN3P0X 1 1/4 in. DN32 34 Cv 29 kvs No pre-assembled actuator None 40 psi 276 kPa
VBN3EH3PRA 1 1/2 in. DN40 4.0 Cv 3.4 kvs Non-Spring Return Floating NEMA 3R 40 psi 276 kPa
VBN3EH3PRB 1 1/2 in. DN40 4.0 Cv 3.4 kvs Non-Spring Return Modulating NEMA 3R 40 psi 276 kPa
VBN3EH3PRC 1 1/2 in. DN40 4.0 Cv 3.4 kvs Spring Return 2-Position, 24Vac NEMA 3R 40 psi 276 kPa
VBN3EH3PRD 1 1/2 in. DN40 4.0 Cv 3.4 kvs Spring Return Floating/Modulating NEMA 3R 40 psi 276 kPa
VBN3EH3P0A 1 1/2 in. DN40 4.0 Cv 3.4 kvs Non-Spring Return Floating None 40 psi 276 kPa
VBN3EH3P0B 1 1/2 in. DN40 4.0 Cv 3.4 kvs Non-Spring Return Modulating None 40 psi 276 kPa
VBN3EH3P0C 1 1/2 in. DN40 4.0 Cv 3.4 kvs Spring Return 2-Position, 24Vac None 40 psi 276 kPa
VBN3EH3P0D 1 1/2 in. DN40 4.0 Cv 3.4 kvs Spring Return Floating/Modulating None 40 psi 276 kPa
VBN3EH3P0X 1 1/2 in. DN40 4.0 Cv 3.4 kvs No pre-assembled actuator None 40 psi 276 kPa
VBN3EJ3PRA 1 1/2 in. DN40 8.3 Cv 7.1 kvs Non-Spring Return Floating NEMA 3R 40 psi 276 kPa
VBN3EJ3PRB 1 1/2 in. DN40 8.3 Cv 7.1 kvs Non-Spring Return Modulating NEMA 3R 40 psi 276 kPa
VBN3EJ3PRC 1 1/2 in. DN40 8.3 Cv 7.1 kvs Spring Return 2-Position, 24Vac NEMA 3R 40 psi 276 kPa
VBN3EJ3PRD 1 1/2 in. DN40 8.3 Cv 7.1 kvs Spring Return Floating/Modulating NEMA 3R 40 psi 276 kPa
VBN3EJ3P0A 1 1/2 in. DN40 8.3 Cv 7.1 kvs Non-Spring Return Floating None 40 psi 276 kPa
VBN3EJ3P0B 1 1/2 in. DN40 8.3 Cv 7.1 kvs Non-Spring Return Modulating None 40 psi 276 kPa
VBN3EJ3P0C 1 1/2 in. DN40 8.3 Cv 7.1 kvs Spring Return 2-Position, 24Vac None 40 psi 276 kPa
VBN3EJ3P0D 1 1/2 in. DN40 8.3 Cv 7.1 kvs Spring Return Floating/Modulating None 40 psi 276 kPa
VBN3EJ3P0X 1 1/2 in. DN40 8.3 Cv 7.1 kvs No pre-assembled actuator None 40 psi 276 kPa
VBN3EK3PRA 1 1/2 in. DN40 13.4 Cv 11.5 kvs Non-Spring Return Floating NEMA 3R 40 psi 276 kPa
VBN3EK3PRB 1 1/2 in. DN40 13.4 Cv 11.5 kvs Non-Spring Return Modulating NEMA 3R 40 psi 276 kPa
VBN3EK3PRC 1 1/2 in. DN40 13.4 Cv 11.5 kvs Spring Return 2-Position, 24Vac NEMA 3R 40 psi 276 kPa
VBN3EK3PRD 1 1/2 in. DN40 13.4 Cv 11.5 kvs Spring Return Floating/Modulating NEMA 3R 40 psi 276 kPa
VBN3EK3P0A 1 1/2 in. DN40 13.4 Cv 11.5 kvs Non-Spring Return Floating None 40 psi 276 kPa

598 customer.honeywell.com 70-6910


Control Ball Valves

Controls
Maximum Close-

Home
Valve Size Flow Capacity off Pressure
Weather
Product Number (inch) DN (Cv) (Kv) Actuation Enclosure (psi) (kPa)
VBN3EK3P0B 1 1/2 in. DN40 13.4 Cv 11.5 kvs Non-Spring Return Modulating None 40 psi 276 kPa
VBN3EK3P0C 1 1/2 in. DN40 13.4 Cv 11.5 kvs Spring Return 2-Position, 24Vac None 40 psi 276 kPa
VBN3EK3P0D 1 1/2 in. DN40 13.4 Cv 11.5 kvs Spring Return Floating/Modulating None 40 psi 276 kPa

Indoor Air Quality


VBN3EK3P0X 1 1/2 in. DN40 13.4 Cv 11.5 kvs No pre-assembled actuator None 40 psi 276 kPa
VBN3EL3PRA 1 1/2 in. DN40 24 Cv 21 kvs Non-Spring Return Floating NEMA 3R 40 psi 276 kPa
VBN3EL3PRB 1 1/2 in. DN40 24 Cv 21 kvs Non-Spring Return Modulating NEMA 3R 40 psi 276 kPa
VBN3EL3PRC 1 1/2 in. DN40 24 Cv 21 kvs Spring Return 2-Position, 24Vac NEMA 3R 40 psi 276 kPa
VBN3EL3PRD 1 1/2 in. DN40 24 Cv 21 kvs Spring Return Floating/Modulating NEMA 3R 40 psi 276 kPa
VBN3EL3P0A 1 1/2 in. DN40 24 Cv 21 kvs Non-Spring Return Floating None 40 psi 276 kPa
VBN3EL3P0B 1 1/2 in. DN40 24 Cv 21 kvs Non-Spring Return Modulating None 40 psi 276 kPa

Combustion Controls
VBN3EL3P0C 1 1/2 in. DN40 24 Cv 21 kvs Spring Return 2-Position, 24Vac None 40 psi 276 kPa
VBN3EL3P0D 1 1/2 in. DN40 24 Cv 21 kvs Spring Return Floating/Modulating None 40 psi 276 kPa

Residential
VBN3EL3P0X 1 1/2 in. DN40 24 Cv 21 kvs No pre-assembled actuator None 40 psi 276 kPa
VBN3EM3PRA 1 1/2 in. DN40 32 Cv 28 kvs Non-Spring Return Floating NEMA 3R 40 psi 276 kPa
VBN3EM3PRB 1 1/2 in. DN40 32 Cv 28 kvs Non-Spring Return Modulating NEMA 3R 40 psi 276 kPa
VBN3EM3PRC 1 1/2 in. DN40 32 Cv 28 kvs Spring Return 2-Position, 24Vac NEMA 3R 40 psi 276 kPa
VBN3EM3PRD 1 1/2 in. DN40 32 Cv 28 kvs Spring Return Floating/Modulating NEMA 3R 40 psi 276 kPa
VBN3EM3P0A 1 1/2 in. DN40 32 Cv 28 kvs Non-Spring Return Floating None 40 psi 276 kPa

Hydronic Controls
VBN3EM3P0B 1 1/2 in. DN40 32 Cv 28 kvs Non-Spring Return Modulating None 40 psi 276 kPa
VBN3EM3P0C 1 1/2 in. DN40 32 Cv 28 kvs Spring Return 2-Position, 24Vac None 40 psi 276 kPa
VBN3EM3P0D 1 1/2 in. DN40 32 Cv 28 kvs Spring Return Floating/Modulating None 40 psi 276 kPa
VBN3EM3P0X 1 1/2 in. DN40 32 Cv 28 kvs No pre-assembled actuator None 40 psi 276 kPa
VBN3EP3PRA 1 1/2 in. DN40 61 Cv 52 kvs Non-Spring Return Floating NEMA 3R 40 psi 276 kPa
VBN3EP3PRB 1 1/2 in. DN40 61 Cv 52 kvs Non-Spring Return Modulating NEMA 3R 40 psi 276 kPa
VBN3EP3PRC 1 1/2 in. DN40 61 Cv 52 kvs Spring Return 2-Position, 24Vac NEMA 3R 40 psi 276 kPa
VBN3EP3PRD 1 1/2 in. DN40 61 Cv 52 kvs Spring Return Floating/Modulating NEMA 3R 40 psi 276 kPa

Controls
VBN3EP3P0A 1 1/2 in. DN40 61 Cv 52 kvs Non-Spring Return Floating None 40 psi 276 kPa

Water
VBN3EP3P0B 1 1/2 in. DN40 61 Cv 52 kvs Non-Spring Return Modulating None 40 psi 276 kPa
VBN3EP3P0C 1 1/2 in. DN40 61 Cv 52 kvs Spring Return 2-Position, 24Vac None 40 psi 276 kPa
VBN3EP3P0D 1 1/2 in. DN40 61 Cv 52 kvs Spring Return Floating/Modulating None 40 psi 276 kPa
VBN3EP3P0X 1 1/2 in. DN40 61 Cv 52 kvs No pre-assembled actuator None 40 psi 276 kPa
VBN3FL3PRA 2 in. DN50 24 Cv 21 kvs Non-Spring Return Floating NEMA 3R 40 psi 276 kPa

Building Automation
VBN3FL3PRB 2 in. DN50 24 Cv 21 kvs Non-Spring Return Modulating NEMA 3R 40 psi 276 kPa
VBN3FL3PRC 2 in. DN50 24 Cv 21 kvs Spring Return 2-Position, 24Vac NEMA 3R 40 psi 276 kPa
VBN3FL3PRD 2 in. DN50 24 Cv 21 kvs Spring Return Floating/Modulating NEMA 3R 40 psi 276 kPa
VBN3FL3P0A 2 in. DN50 24 Cv 21 kvs Non-Spring Return Floating None 40 psi 276 kPa
VBN3FL3P0B 2 in. DN50 24 Cv 21 kvs Non-Spring Return Modulating None 40 psi 276 kPa
VBN3FL3P0C 2 in. DN50 24 Cv 21 kvs Spring Return 2-Position, 24Vac None 40 psi 276 kPa
VBN3FL3P0D 2 in. DN50 24 Cv 21 kvs Spring Return Floating/Modulating None 40 psi 276 kPa
VBN3FL3P0X 2 in. DN50 24 Cv 21 kvs No pre-assembled actuator None 40 psi 276 kPa

Components
Commercial
VBN3FN3PRA 2 in. DN50 38 Cv 33 kvs Non-Spring Return Floating NEMA 3R 40 psi 276 kPa
VBN3FN3PRB 2 in. DN50 38 Cv 33 kvs Non-Spring Return Modulating NEMA 3R 40 psi 276 kPa
VBN3FN3PRC 2 in. DN50 38 Cv 33 kvs Spring Return 2-Position, 24Vac NEMA 3R 40 psi 276 kPa
VBN3FN3PRD 2 in. DN50 38 Cv 33 kvs Spring Return Floating/Modulating NEMA 3R 40 psi 276 kPa
VBN3FN3P0A 2 in. DN50 38 Cv 33 kvs Non-Spring Return Floating None 40 psi 276 kPa
VBN3FN3P0B 2 in. DN50 38 Cv 33 kvs Non-Spring Return Modulating None 40 psi 276 kPa
Pneumatic Controls

VBN3FN3P0C 2 in. DN50 38 Cv 33 kvs Spring Return 2-Position, 24Vac None 40 psi 276 kPa
VBN3FN3P0D 2 in. DN50 38 Cv 33 kvs Spring Return Floating/Modulating None 40 psi 276 kPa
VBN3FN3P0X 2 in. DN50 38 Cv 33 kvs No pre-assembled actuator None 40 psi 276 kPa
VBN3FP3PRA 2 in. DN50 57 Cv 49 kvs Non-Spring Return Floating NEMA 3R 40 psi 276 kPa
VBN3FP3PRB 2 in. DN50 57 Cv 49 kvs Non-Spring Return Modulating NEMA 3R 40 psi 276 kPa
VBN3FP3PRC 2 in. DN50 57 Cv 49 kvs Spring Return 2-Position, 24Vac NEMA 3R 40 psi 276 kPa
VBN3FP3PRD 2 in. DN50 57 Cv 49 kvs Spring Return Floating/Modulating NEMA 3R 40 psi 276 kPa
Industrial Combustion

VBN3FP3P0A 2 in. DN50 57 Cv 49 kvs Non-Spring Return Floating None 40 psi 276 kPa
VBN3FP3P0B 2 in. DN50 57 Cv 49 kvs Non-Spring Return Modulating None 40 psi 276 kPa
Controls

VBN3FP3P0C 2 in. DN50 57 Cv 49 kvs Spring Return 2-Position, 24Vac None 40 psi 276 kPa
VBN3FP3P0D 2 in. DN50 57 Cv 49 kvs Spring Return Floating/Modulating None 40 psi 276 kPa

70-6910 599
Control Ball Valves
Maximum Close-
Valve Size Flow Capacity off Pressure
Weather
Product Number (inch) DN (Cv) (Kv) Actuation Enclosure (psi) (kPa)
VBN3FP3P0X 2 in. DN50 57 Cv 49 kvs No pre-assembled actuator None 40 psi 276 kPa
VBN3FR3PRA 2 in. DN50 83 Cv 71 kvs Non-Spring Return Floating NEMA 3R 40 psi 276 kPa
VBN3FR3PRB 2 in. DN50 83 Cv 71 kvs Non-Spring Return Modulating NEMA 3R 40 psi 276 kPa
VBN3FR3PRC 2 in. DN50 83 Cv 71 kvs Spring Return 2-Position, 24Vac NEMA 3R 40 psi 276 kPa
VBN3FR3PRD 2 in. DN50 83 Cv 71 kvs Spring Return Floating/Modulating NEMA 3R 40 psi 276 kPa
VBN3FR3P0A 2 in. DN50 83 Cv 71 kvs Non-Spring Return Floating None 40 psi 276 kPa
VBN3FR3P0B 2 in. DN50 83 Cv 71 kvs Non-Spring Return Modulating None 40 psi 276 kPa
VBN3FR3P0C 2 in. DN50 83 Cv 71 kvs Spring Return 2-Position, 24Vac None 40 psi 276 kPa
VBN3FR3P0D 2 in. DN50 83 Cv 71 kvs Spring Return Floating/Modulating None 40 psi 276 kPa
VBN3FR3P0X 2 in. DN50 83 Cv 71 kvs No pre-assembled actuator None 40 psi 276 kPa
VBN3FT3PRA 2 in. DN50 109 Cv 94 kvs Non-Spring Return Floating NEMA 3R 40 psi 276 kPa
VBN3FT3PRB 2 in. DN50 109 Cv 94 kvs Non-Spring Return Modulating NEMA 3R 40 psi 276 kPa
VBN3FT3PRC 2 in. DN50 109 Cv 94 kvs Spring Return 2-Position, 24Vac NEMA 3R 40 psi 276 kPa
VBN3FT3PRD 2 in. DN50 109 Cv 94 kvs Spring Return Floating/Modulating NEMA 3R 40 psi 276 kPa
VBN3FT3P0A 2 in. DN50 109 Cv 94 kvs Non-Spring Return Floating None 40 psi 276 kPa
VBN3FT3P0B 2 in. DN50 109 Cv 94 kvs Non-Spring Return Modulating None 40 psi 276 kPa
VBN3FT3P0C 2 in. DN50 109 Cv 94 kvs Spring Return 2-Position, 24Vac None 40 psi 276 kPa
VBN3FT3P0D 2 in. DN50 109 Cv 94 kvs Spring Return Floating/Modulating None 40 psi 276 kPa
VBN3FT3P0X 2 in. DN50 109 Cv 94 kvs No pre-assembled actuator None 40 psi 276 kPa
VBN3GN3PRA 2 1/2 in. DN65 38 Cv 33 kvs Non-Spring Return Floating NEMA 3R 40 psi 276 kPa
VBN3GN3PRB 2 1/2 in. DN65 38 Cv 33 kvs Non-Spring Return Modulating NEMA 3R 40 psi 276 kPa
VBN3GN3PRC 2 1/2 in. DN65 38 Cv 33 kvs Spring Return 2-Position, 24Vac NEMA 3R 40 psi 276 kPa
VBN3GN3PRD 2 1/2 in. DN65 38 Cv 33 kvs Spring Return Floating/Modulating NEMA 3R 40 psi 276 kPa
VBN3GN3P0A 2 1/2 in. DN65 38 Cv 33 kvs Non-Spring Return Floating None 40 psi 276 kPa
VBN3GN3P0B 2 1/2 in. DN65 38 Cv 33 kvs Non-Spring Return Modulating None 40 psi 276 kPa
VBN3GN3P0C 2 1/2 in. DN65 38 Cv 33 kvs Spring Return 2-Position, 24Vac None 40 psi 276 kPa
VBN3GN3P0D 2 1/2 in. DN65 38 Cv 33 kvs Spring Return Floating/Modulating None 40 psi 276 kPa
VBN3GN3P0X 2 1/2 in. DN65 38 Cv 33 kvs No pre-assembled actuator None 40 psi 276 kPa
VBN3GR3PRA 2 1/2 in. DN65 74 Cv 64 kvs Non-Spring Return Floating NEMA 3R 40 psi 276 kPa
VBN3GR3PRB 2 1/2 in. DN65 74 Cv 64 kvs Non-Spring Return Modulating NEMA 3R 40 psi 276 kPa
VBN3GR3PRC 2 1/2 in. DN65 74 Cv 64 kvs Spring Return 2-Position, 24Vac NEMA 3R 40 psi 276 kPa
VBN3GR3PRD 2 1/2 in. DN65 74 Cv 64 kvs Spring Return Floating/Modulating NEMA 3R 40 psi 276 kPa
VBN3GR3P0A 2 1/2 in. DN65 74 Cv 64 kvs Non-Spring Return Floating None 40 psi 276 kPa
VBN3GR3P0B 2 1/2 in. DN65 74 Cv 64 kvs Non-Spring Return Modulating None 40 psi 276 kPa
VBN3GR3P0C 2 1/2 in. DN65 74 Cv 64 kvs Spring Return 2-Position, 24Vac None 40 psi 276 kPa
VBN3GR3P0D 2 1/2 in. DN65 74 Cv 64 kvs Spring Return Floating/Modulating None 40 psi 276 kPa
VBN3GR3P0X 2 1/2 in. DN65 74 Cv 64 kvs No pre-assembled actuator None 40 psi 276 kPa
VBN3GS3PRA 2 1/2 in. DN65 100 Cv 86 kvs Non-Spring Return Floating NEMA 3R 40 psi 276 kPa
VBN3GS3PRB 2 1/2 in. DN65 100 Cv 86 kvs Non-Spring Return Modulating NEMA 3R 40 psi 276 kPa
VBN3GS3PRC 2 1/2 in. DN65 100 Cv 86 kvs Spring Return 2-Position, 24Vac NEMA 3R 40 psi 276 kPa
VBN3GS3PRD 2 1/2 in. DN65 100 Cv 86 kvs Spring Return Floating/Modulating NEMA 3R 40 psi 276 kPa
VBN3GS3P0A 2 1/2 in. DN65 100 Cv 86 kvs Non-Spring Return Floating None 40 psi 276 kPa
VBN3GS3P0B 2 1/2 in. DN65 100 Cv 86 kvs Non-Spring Return Modulating None 40 psi 276 kPa
VBN3GS3P0C 2 1/2 in. DN65 100 Cv 86 kvs Spring Return 2-Position, 24Vac None 40 psi 276 kPa
VBN3GS3P0D 2 1/2 in. DN65 100 Cv 86 kvs Spring Return Floating/Modulating None 40 psi 276 kPa
VBN3GS3P0X 2 1/2 in. DN65 100 Cv 86 kvs No pre-assembled actuator None 40 psi 276 kPa

600 customer.honeywell.com 70-6910


Butterfly Control Valves
VFF1, VFF2, VFF3, VFF6 Butterfly Control Valves

Controls
Home
Actuator Type
Specification

Specification
(close-off)

secondary
Valve trim
Disk size

Pressure
Butterfly

Actuator

Actuator
primary
Pattern
Valves

Rating
Fitting

Body

Size

Indoor Air Quality


Description
VF Butterfly Valve, resilient seat
F Flanged fitting
1 2-way (spring return normally open)
2 2-way (non-spring return or electric spring return direct coupled, factory set to normally closed, and field-convertible to normally open)
3 3-way A-B-AB (mixing/diverting)
6 3-way A-AB-B (diverting/mixing)

Combustion Controls
F 2 inch (DN50)

Residential
G 2-1/2 inch (DN65)
H 3 inch (DN80)
J 4 inch (DN100)
K 5 inch (DN125)
L 6 inch (DN150)
M 8 inch (DN200)
N 10 inch (DN250)

Hydronic Controls
P 12 inch (DN300)
R 14 inch (DN350)
S 16 inch (DN400)
T 18 inch (DN450)
U 20 inch (DN500)
V Undercut disk (lower actuator torque; 50 psid close-off)
W Full diameter disk (high close-off)
1 ANSI 150 psig body pressure rating

Controls
2 ANSI 250 psig body pressure rating

Water
Y Nylon-coated disk, EPDM seat
2 NEMA 2 actuator housing (Honeywell DCA)

Electric
6 NEMA 6 actuator housing with manual operator and heater
X NEMA 4X actuator housing with manual operator and heater
8 Spring Range 8-13 psi for 20 psi pneumatic actuator

Building Automation
C 24 Vac solenoid for 80 psi pneumatic actuator

Pneumatic
D Electro-pneumatic positioner for 80 psi actuator
E 120 Vac solenoid for 80 psi pneumatic actuator
P Pneumatic positioner for modulating applications
X Standard, two-position control only
Lever operator for dead end service

Manual
L
G Geared operator for dead end service

Components
A Floating actuator

Commercial
B Modulating actuator Electric
C Two-position 24 Vac spring return actuator
D Modulating spring return actuator
E Two-position 120 Vac spring return actuator
Pneumatic actuator, spring return 20 psi
Man Pneumatic

P
Pneumatic actuator, push-pull 80 psi (140 psi maximum)
Pneumatic Controls

R
S Pneumatic actuator, spring return 80 psi (140 psi maximum)

Valve body only, for dead end service


X

2-way, 4 inch flanged resilient-sear butterfly valve, undercut disk (50 psid close-
VF F 2 J V 1 Y 2 D off) modulating/floating control, spring return normally closed.
Industrial Combustion
Controls

70-6910 601
Butterfly Control Valves
VFF1 Two-way Normally-Open Butterfly Control Valves
Body Pattern: 2 way (S/R NO)
Valve Action: Normally Open
Connection Type: Lugged
Controlled Fluid: Chilled or hot water with up to 50% Glycol. Not for
use with steam or fuels.
Actuator Control Type: Pneumatic
Type of Enclosure: Pneumatic
Flow Characteristic: Modified Equal Percent
Mounting: ANSI Flanged
Static Pressure Rating (max): 250 psi (1724 kPa)
Actuator Ambient Temperature Ratings: -
20 F to 150 F (-29 C to 66 C)
Temperature Range: -40 F to 250 F (-40 C to 121 C)
Number of Flange Bolts
For 2 in., 2-1/2 in., 3 in. valves: 4
For 4 in., 5 in., 6 in., 8 in., valves: 8
For 10 in., 12 in., 14 in. valves: 12
For 16 in., 18 in. valves: 16
For 20 in. valves: 20
Flange Bolt Thread
For 2 in., 2-1/2 in., 3 in. valves: 5/8 in.-11 pitch
For 4 in., 5 in., 6 in., 8 in., valves: 3/4 in.-10 pitch
For 10 in., 12 in., 14 in. valves: 7/8 in.-9 pitch
For 16 in., 18 in., 20 in. valves: 1-1/8 in.-7 pitch
Materials
(Body): Polyester-coated cast iron ASTM A126 Class B
Resilient seat in two-way valves, provide control for HVAC system (Stem): 416 Stainless Steel
applications including chilled water, hot water, cooling tower (Seat): Peroxide-cured EPDM resilient seat
water, and thermal storage systems. (Plug/Ball/Disc): Nylon 11-coated ductile iron

Maximum
Differential
Capacity at 60 Capacity at 90 Pressure Ratings
Valve Size degrees stroke degrees stroke (Close-off)
Product Number (inch) (DN) (Cv) (Kv) (Cv) (Kv) Actuator Selection (psi) (kPa) Comments Includes
VFF1FW1Y8P 2 in. DN50 61 Cv 53 kvs Stroke limited to 70 20 psi spring return 175 psi 1206 kPa Linear actuator —
degrees
VFF1FW1YES 2 in. DN50 61 Cv 53 kvs 144 Cv 125 kvs 2-position, 120 Vac solenoid 80 psi 175 psi 1206 kPa — Position indicator
spring return
VFF1FW1YCS 2 in. DN50 61 Cv 53 kvs 144 Cv 125 kvs 2-position, 24 Vac solenoid 80 psi 175 psi 1206 kPa — Position indicator
spring return
VFF1FW1YXS 2 in. DN50 61 Cv 53 kvs 144 Cv 125 kvs 2-position, 80 psi spring return 175 psi 1206 kPa — Position indicator
VFF1FW1YDS 2 in. DN50 61 Cv 53 kvs 144 Cv 125 kvs 4-20 mA Servo, 80 psi spring return 175 psi 1206 kPa — Position indicator
VFF1FW1YPP 2 in. DN50 61 Cv 53 kvs Stroke limited to 70 Modulating w/positioner, spring return 175 psi 1206 kPa Linear actuator —
degrees
VFF1FW1YPS 2 in. DN50 61 Cv 53 kvs 144 Cv 125 kvs Modulating w/positioner, spring return 175 psi 1206 kPa — Position indicator
VFF1GW1Y8P 2-1/2 in. DN65 107 Cv 93 kvs Stroke limited to 70 20 psi spring return 175 psi 1206 kPa Linear actuator —
degrees
VFF1GW1YES 2-1/2 in. DN65 107 Cv 93 kvs 282 Cv 244 kvs 2-position, 120 Vac solenoid 80 psi 175 psi 1206 kPa — Position indicator
spring return
VFF1GW1YCS 2-1/2 in. DN65 107 Cv 93 kvs 282 Cv 244 kvs 2-position, 24 Vac solenoid 80 psi 175 psi 1206 kPa — Position indicator
spring return
VFF1GW1YXS 2-1/2 in. DN65 107 Cv 93 kvs 282 Cv 244 kvs 2-position, 80 psi spring return 175 psi 1206 kPa — Position indicator
VFF1GW1YDS 2-1/2 in. DN65 107 Cv 93 kvs 282 Cv 244 kvs 4-20 mA Servo, 80 psi spring return 175 psi 1206 kPa — Position indicator
VFF1GW1YPP 2-1/2 in. DN65 107 Cv 93 kvs Stroke limited to 70 Modulating w/positioner, spring return 175 psi 1206 kPa Linear actuator —
degrees
VFF1GW1YPS 2-1/2 in. DN65 107 Cv 93 kvs 282 Cv 244 kvs Modulating w/positioner, spring return 175 psi 1206 kPa — Position indicator
VFF1HW1Y8P 3 in. DN80 154 Cv 133 kvs Stroke limited to 70 20 psi spring return 175 psi 1206 kPa Linear actuator —
degrees
VFF1HW1YES 3 in. DN80 154 Cv 133 kvs 461 Cv 399 kvs 2-position, 120 Vac solenoid 80 psi 175 psi 1206 kPa — Position indicator
spring return
VFF1HW1YCS 3 in. DN80 154 Cv 133 kvs 461 Cv 399 kvs 2-position, 24 Vac solenoid 80 psi 175 psi 1206 kPa — Position indicator
spring return
VFF1HW1YXS 3 in. DN80 154 Cv 133 kvs 461 Cv 399 kvs 2-position, 80 psi spring return 175 psi 1206 kPa — Position indicator
VFF1HW1YDS 3 in. DN80 154 Cv 133 kvs 461 Cv 399 kvs 4-20 mA Servo, 80 psi spring return 175 psi 1206 kPa — Position indicator
VFF1HW1YPP 3 in. DN80 154 Cv 133 kvs Stroke limited to 70 Modulating w/positioner, spring return 175 psi 1206 kPa Linear actuator —
degrees
VFF1HW1YPS 3 in. DN80 154 Cv 133 kvs 461 Cv 399 kvs Modulating w/positioner, spring return 175 psi 1206 kPa — Position indicator

602 customer.honeywell.com 70-6910


Butterfly Control Valves

Controls
Maximum

Home
Differential
Capacity at 60 Capacity at 90 Pressure Ratings
Valve Size degrees stroke degrees stroke (Close-off)
Product Number (inch) (DN) (Cv) (Kv) (Cv) (Kv) Actuator Selection (psi) (kPa) Comments Includes
VFF1JV1Y8P 4 in. DN100 274 Cv 237 kvs Stroke limited to 70 20 psi spring return 50 psi 345 kPa Linear actuator —
degrees
VFF1JW1Y8P 4 in. DN100 274 Cv 237 kvs Stroke limited to 70 20 psi spring return 175 psi 1206 kPa Linear actuator —

Indoor Air Quality


degrees
VFF1JV1YES 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs 2-position, 120 Vac solenoid 80 psi 50 psi 345 kPa — Position indicator
spring return
VFF1JW1YES 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs 2-position, 120 Vac solenoid 80 psi 175 psi 1206 kPa — Position indicator
spring return
VFF1JV1YCS 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs 2-position, 24 Vac solenoid 80 psi 50 psi 345 kPa — Position indicator
spring return
VFF1JW1YCS 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs 2-position, 24 Vac solenoid 80 psi 175 psi 1206 kPa — Position indicator

Combustion Controls
spring return

Residential
VFF1JV1YXS 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs 2-position, 80 psi spring return 50 psi 345 kPa — Position indicator
VFF1JW1YXS 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs 2-position, 80 psi spring return 175 psi 1206 kPa — Position indicator
VFF1JV1YDS 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs 4-20 mA Servo, 80 psi spring return 50 psi 345 kPa — Position indicator
VFF1JW1YDS 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs 4-20 mA Servo, 80 psi spring return 175 psi 1206 kPa — Position indicator
VFF1JV1YPP 4 in. DN100 274 Cv 237 kvs Stroke limited to 70 Modulating w/positioner, spring return 50 psi 345 kPa Linear actuator —
degrees
VFF1JV1YPS 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs Modulating w/positioner, spring return 50 psi 345 kPa — Position indicator

Hydronic Controls
VFF1JW1YPP 4 in. DN100 274 Cv 237 kvs Stroke limited to 70 Modulating w/positioner, spring return 175 psi 1206 kPa Linear actuator —
degrees
VFF1JW1YPS 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs Modulating w/positioner, spring return 175 psi 1206 kPa — Position indicator
VFF1KV1Y8P 5 in. DN125 428 Cv 370 kvs Stroke limited to 70 20 psi spring return 50 psi 345 kPa Linear actuator —
degrees
VFF1KW1Y8P 5 in. DN125 428 Cv 370 kvs Stroke limited to 70 20 psi spring return 175 psi 1206 kPa Linear actuator —
degrees
VFF1KV1YES 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs 2-position, 120 Vac solenoid 80 psi 50 psi 345 kPa — Position indicator
spring return
VFF1KW1YES 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs 2-position, 120 Vac solenoid 80 psi 175 psi 1206 kPa — Position indicator

Controls
spring return

Water
VFF1KV1YCS 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs 2-position, 24 Vac solenoid 80 psi 50 psi 345 kPa — Position indicator
spring return
VFF1KW1YCS 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs 2-position, 24 Vac solenoid 80 psi 175 psi 1206 kPa — Position indicator
spring return
VFF1KV1YXS 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs 2-position, 80 psi spring return 50 psi 345 kPa — Position indicator

Building Automation
VFF1KW1YXS 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs 2-position, 80 psi spring return 175 psi 1206 kPa — Position indicator
VFF1KV1YDS 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs 4-20 mA Servo, 80 psi spring return 50 psi 345 kPa — Position indicator
VFF1KW1YDS 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs 4-20 mA Servo, 80 psi spring return 175 psi 1206 kPa — Position indicator
VFF1KV1YPP 5 in. DN125 428 Cv 370 kvs Stroke limited to 70 Modulating w/positioner, spring return 50 psi 345 kPa Linear actuator —
degrees
VFF1KV1YPS 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs Modulating w/positioner, spring return 50 psi 345 kPa — Position indicator
VFF1KW1YPP 5 in. DN125 428 Cv 370 kvs Stroke limited to 70 Modulating w/positioner, spring return 175 psi 1206 kPa Linear actuator —
degrees
VFF1KW1YPS 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs Modulating w/positioner, spring return 175 psi 1206 kPa — Position indicator

Components
VFF1LW1Y8P 6 in. DN150 567 Cv 490 kvs Stroke limited to 70 20 psi spring return 175 psi 1206 kPa Linear actuator —

Commercial
degrees
VFF1LV1YES 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs 2-position, 120 Vac solenoid 80 psi 50 psi 345 kPa — Position indicator
spring return
VFF1LW1YES 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs 2-position, 120 Vac solenoid 80 psi 175 psi 1206 kPa — Position indicator
spring return
VFF1LV1YCS 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs 2-position, 24 Vac solenoid 80 psi 50 psi 345 kPa — Position indicator
spring return
Pneumatic Controls

VFF1LW1YCS 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs 2-position, 24 Vac solenoid 80 psi 175 psi 1206 kPa — Position indicator
spring return
VFF1LV1YXS 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs 2-position, 80 psi spring return 50 psi 345 kPa — Position indicator
VFF1LW1YXS 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs 2-position, 80 psi spring return 175 psi 1206 kPa — Position indicator
VFF1LV1YDS 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs 4-20 mA Servo, 80 psi spring return 50 psi 345 kPa — Position indicator
VFF1LW1YDS 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs 4-20 mA Servo, 80 psi spring return 175 psi 1206 kPa — Position indicator
VFF1LV1YPS 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs Modulating w/positioner, spring return 50 psi 345 kPa — Position indicator
Industrial Combustion

VFF1LW1YPP 6 in. DN150 567 Cv 490 kvs Stroke limited to 70 Modulating w/positioner, spring return 175 psi 1206 kPa Linear actuator —
degrees
Controls

VFF1LW1YPS 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs Modulating w/positioner, spring return 175 psi 1206 kPa — Position indicator

70-6910 603
Butterfly Control Valves
Maximum
Differential
Capacity at 60 Capacity at 90 Pressure Ratings
Valve Size degrees stroke degrees stroke (Close-off)
Product Number (inch) (DN) (Cv) (Kv) (Cv) (Kv) Actuator Selection (psi) (kPa) Comments Includes
VFF1MV1Y8P 8 in. DN200 1081 Cv 935 kvs Stroke limited to 70 20 psi spring return 50 psi 345 kPa Linear actuator —
degrees
VFF1MW1Y8P 8 in. DN200 1081 Cv 935 kvs Stroke limited to 70 20 psi spring return 175 psi 1206 kPa Linear actuator —
degrees
VFF1MV1YES 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs 2-position, 120 Vac solenoid 80 psi 50 psi 345 kPa — Position indicator
spring return
VFF1MW1YES 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs 2-position, 120 Vac solenoid 80 psi 175 psi 1206 kPa — Position indicator
spring return
VFF1MV1YCS 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs 2-position, 24 Vac solenoid 80 psi 50 psi 345 kPa — Position indicator
spring return
VFF1MW1YCS 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs 2-position, 24 Vac solenoid 80 psi 175 psi 1206 kPa — Position indicator
spring return
VFF1MV1YXS 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs 2-position, 80 psi spring return 50 psi 345 kPa — Position indicator
VFF1MW1YXS 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs 2-position, 80 psi spring return 175 psi 1206 kPa — Position indicator
VFF1MV1YDS 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs 4-20 mA Servo, 80 psi spring return 50 psi 345 kPa — Position indicator
VFF1MW1YDS 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs 4-20 mA Servo, 80 psi spring return 175 psi 1206 kPa — Position indicator
VFF1MV1YPP 8 in. DN200 1081 Cv 935 kvs Stroke limited to 70 Modulating w/positioner, spring return 50 psi 345 kPa Linear actuator —
degrees
VFF1MV1YPS 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs Modulating w/positioner, spring return 50 psi 345 kPa — Position indicator
VFF1MW1YPP 8 in. DN200 1081 Cv 935 kvs Stroke limited to 70 Modulating w/positioner, spring return 175 psi 1206 kPa Linear actuator —
degrees
VFF1MW1YPS 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs Modulating w/positioner, spring return 175 psi 1206 kPa — Position indicator
VFF1NV1Y8P 10 in. DN250 1710 Cv 1479 kvs Stroke limited to 70 20 psi spring return 50 psi 345 kPa Linear actuator —
degrees
VFF1NV1YES 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs 2-position, 120 Vac solenoid 80 psi 50 psi 345 kPa — Position indicator
spring return
VFF1NW1YES 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs 2-position, 120 Vac solenoid 80 psi 175 psi 1206 kPa — Position indicator
spring return
VFF1NV1YCS 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs 2-position, 24 Vac solenoid 80 psi 50 psi 345 kPa — Position indicator
spring return
VFF1NW1YCS 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs 2-position, 24 Vac solenoid 80 psi 175 psi 1206 kPa — Position indicator
spring return
VFF1NV1YXS 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs 2-position, 80 psi spring return 50 psi 345 kPa — Position indicator
VFF1NW1YXS 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs 2-position, 80 psi spring return 175 psi 1206 kPa — Position indicator
VFF1NV1YDS 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs 4-20 mA Servo, 80 psi spring return 50 psi 345 kPa — Position indicator
VFF1NW1YDS 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs 4-20 mA Servo, 80 psi spring return 175 psi 1206 kPa — Position indicator
VFF1NV1YPP 10 in. DN250 1710 Cv 1479 kvs Stroke limited to 70 Modulating w/positioner, spring return 50 psi 345 kPa Linear actuator —
degrees
VFF1NV1YPS 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs Modulating w/positioner, spring return 50 psi 345 kPa — Position indicator
VFF1NW1YPS 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs Modulating w/positioner, spring return 175 psi 1206 kPa — Position indicator
VFF1PV1YES 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs 2-position, 120 Vac solenoid 80 psi 50 psi 345 kPa — Position indicator
spring return
VFF1PW1YES 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs 2-position, 120 Vac solenoid 80 psi 175 psi 1206 kPa — Position indicator
spring return
VFF1PV1YCS 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs 2-position, 24 Vac solenoid 80 psi 50 psi 345 kPa — Position indicator
spring return
VFF1PW1YCS 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs 2-position, 24 Vac solenoid 80 psi 175 psi 1206 kPa — Position indicator
spring return
VFF1PV1YXS 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs 2-position, 80 psi spring return 50 psi 345 kPa — Position indicator
VFF1PW1YXS 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs 2-position, 80 psi spring return 175 psi 1206 kPa — Position indicator
VFF1PV1YDS 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs 4-20 mA Servo, 80 psi spring return 50 psi 345 kPa — Position indicator
VFF1PW1YDS 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs 4-20 mA Servo, 80 psi spring return 175 psi 1206 kPa — Position indicator
VFF1PV1YPS 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs Modulating w/positioner, spring return 50 psi 345 kPa — Position indicator
VFF1PW1YPS 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs Modulating w/positioner, spring return 175 psi 1206 kPa — Position indicator
VFF1RV1YES 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs 2-position, 120 Vac solenoid 80 psi 50 psi 345 kPa — Position indicator
spring return
VFF1RW1YES 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs 2-position, 120 Vac solenoid 80 psi 150 psi 1034 kPa — Position indicator
spring return
VFF1RV1YCS 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs 2-position, 24 Vac solenoid 80 psi 50 psi 345 kPa — Position indicator
spring return
VFF1RW1YCS 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs 2-position, 24 Vac solenoid 80 psi 150 psi 1034 kPa — Position indicator
spring return
VFF1RV1YXS 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs 2-position, 80 psi spring return 50 psi 345 kPa — Position indicator

604 customer.honeywell.com 70-6910


Butterfly Control Valves

Controls
Maximum

Home
Differential
Capacity at 60 Capacity at 90 Pressure Ratings
Valve Size degrees stroke degrees stroke (Close-off)
Product Number (inch) (DN) (Cv) (Kv) (Cv) (Kv) Actuator Selection (psi) (kPa) Comments Includes
VFF1RW1YXS 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs 2-position, 80 psi spring return 150 psi 1034 kPa — Position indicator
VFF1RV1YDS 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs 4-20 mA Servo, 80 psi spring return 50 psi 345 kPa — Position indicator

Indoor Air Quality


VFF1RW1YDS 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs 4-20 mA Servo, 80 psi spring return 150 psi 1034 kPa — Position indicator
VFF1RV1YPS 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs Modulating w/positioner, spring return 50 psi 345 kPa — Position indicator
VFF1RW1YPS 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs Modulating w/positioner, spring return 150 psi 1034 kPa — Position indicator
VFF1SV1YES 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs 2-position, 120 Vac solenoid 80 psi 50 psi 345 kPa — Position indicator
spring return
VFF1SW1YES 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs 2-position, 120 Vac solenoid 80 psi 150 psi 1034 kPa — Position indicator
spring return
VFF1SV1YCS 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs 2-position, 24 Vac solenoid 80 psi 50 psi 345 kPa — Position indicator

Combustion Controls
spring return

Residential
VFF1SW1YCS 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs 2-position, 24 Vac solenoid 80 psi 150 psi 1034 kPa — Position indicator
spring return
VFF1SV1YXS 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs 2-position, 80 psi spring return 50 psi 345 kPa — Position indicator
VFF1SW1YXS 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs 2-position, 80 psi spring return 150 psi 1034 kPa — Position indicator
VFF1SV1YDS 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs 4-20 mA Servo, 80 psi spring return 50 psi 345 kPa — Position indicator
VFF1SW1YDS 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs 4-20 mA Servo, 80 psi spring return 150 psi 1034 kPa — Position indicator
VFF1SV1YPS 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs Modulating w/positioner, spring return 50 psi 345 kPa — Position indicator

Hydronic Controls
VFF1SW1YPS 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs Modulating w/positioner, spring return 150 psi 1034 kPa — Position indicator
VFF1TV1YES 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs 2-position, 120 Vac solenoid 80 psi 50 psi 345 kPa — Position indicator
spring return
VFF1TW1YES 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs 2-position, 120 Vac solenoid 80 psi 150 psi 1034 kPa — Position indicator
spring return
VFF1TV1YCS 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs 2-position, 24 Vac solenoid 80 psi 50 psi 345 kPa — Position indicator
spring return
VFF1TW1YCS 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs 2-position, 24 Vac solenoid 80 psi 150 psi 1034 kPa — Position indicator
spring return
VFF1TV1YXS 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs 2-position, 80 psi spring return 50 psi 345 kPa — Position indicator

Controls
Water
VFF1TW1YXS 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs 2-position, 80 psi spring return 150 psi 1034 kPa — Position indicator
VFF1TV1YDS 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs 4-20 mA Servo, 80 psi spring return 50 psi 345 kPa — Position indicator
VFF1TW1YDS 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs 4-20 mA Servo, 80 psi spring return 150 psi 1034 kPa — Position indicator
VFF1TV1YPS 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs Modulating w/positioner, spring return 50 psi 345 kPa — Position indicator
VFF1TW1YPS 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs Modulating w/positioner, spring return 150 psi 1034 kPa — Position indicator

Building Automation
VFF1UV1YES 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs 2-position, 120 Vac solenoid 80 psi 50 psi 345 kPa — Position indicator
spring return
VFF1UW1YES 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs 2-position, 120 Vac solenoid 80 psi 150 psi 1034 kPa — Position indicator
spring return
VFF1UV1YCS 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs 2-position, 24 Vac solenoid 80 psi 50 psi 345 kPa — Position indicator
spring return
VFF1UW1YCS 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs 2-position, 24 Vac solenoid 80 psi 150 psi 1034 kPa — Position indicator
spring return
VFF1UV1YXS 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs 2-position, 80 psi spring return 50 psi 345 kPa — Position indicator
VFF1UW1YXS 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs 2-position, 80 psi spring return 150 psi 1034 kPa — Position indicator

Components
Commercial
VFF1UV1YDS 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs 4-20 mA Servo, 80 psi spring return 50 psi 345 kPa — Position indicator
VFF1UW1YDS 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs 4-20 mA Servo, 80 psi spring return 150 psi 1034 kPa — Position indicator
VFF1UV1YPS 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs Modulating w/positioner, spring return 50 psi 345 kPa — Position indicator
VFF1UW1YPS 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs Modulating w/positioner, spring return 150 psi 1034 kPa — Position indicator
Pneumatic Controls
Industrial Combustion
Controls

70-6910 605
Butterfly Control Valves
VFF2 Two-way Butterfly Control Valves
Body Pattern: 2 way (NC, NC/NO; NSR)
Valve Action: Normally Closed, convertible to Normally Open with
Spring Return DCA
Connection Type: Lugged
Controlled Fluid: Chilled or hot water with up to 50% Glycol. Not for
use with steam or fuels.
Flow Characteristic: Modified Equal Percent
Mounting: ANSI Flanged
Static Pressure Rating (max): 250 psi (1724 kPa)
Actuator Ambient Temperature Ratings: -5 F to 140 F (-20 C to 60 C)
Temperature Range: -40 F to 250 F (-40 C to 121 C)
Number of Flange Bolts
For 2 in., 2-1/2 in., 3 in. valves: 4
For 4 in., 5 in., 6 in., 8 in., valves: 8
For 10 in., 12 in., 14 in. valves: 12
For 16 in., 18 in. valves: 16
For 20 in. valves: 20
Flange Bolt Thread
For 2 in., 2-1/2 in., 3 in. valves: 5/8 in.-11 pitch
For 4 in., 5 in., 6 in., 8 in., valves: 3/4 in.-10 pitch
For 10 in., 12 in., 14 in. valves: 7/8 in.-9 pitch
For 16 in., 18 in., 20 in. valves: 1-1/8 in.-7 pitch
Materials
(Body): Polyester-coated cast iron ASTM A126 Class B
(Stem): 416 Stainless Steel
(Seat): Peroxide-cured EPDM resilient seat
(Plug/Ball/Disc): Nylon 11-coated ductile iron
Approvals:
CE: Compliant
Underwriters Laboratories, Inc. C/US UL873, Plenum Rated
Resilient seat two-way valves provide control for HVAC system
applications including chilled water, hot water, cooling tower Accessories:
water, and thermal storage systems. VFF50-0400 Position status monitor for VFF butterfly valves with high
pressure pneumatic actuators
Valves with Electric Actuator

Maximum
Differential
Pressure
Capacity at 60 Capacity at 90 Ratings
Valve Size degrees stroke degrees stroke (Close-off)
Type of
Product Number (inch) (DN) (Cv) (Kv) (Cv) (Kv) Actuator Selection Enclosure (psi) (kPa) Comments Includes
VFF2FW1Y2A 2 in. DN50 61 Cv 53 kvs 144 Cv 125 kvs Non-Spring Return NEMA 2 housing 175 psi 1206 kPa — —
Floating control
VFF2FW1Y2B 2 in. DN50 61 Cv 53 kvs 144 Cv 125 kvs Non-Spring Return NEMA 2 housing 175 psi 1206 kPa — —
Modulating control
VFF2FW1Y2C 2 in. DN50 61 Cv 53 kvs 144 Cv 125 kvs Spring Return 2- NEMA 2 housing 175 psi 1206 kPa — —
Position, 24 Vac
VFF2FW1Y2D 2 in. DN50 61 Cv 53 kvs 144 Cv 125 kvs Spring Return Floating/ NEMA 2 housing 175 psi 1206 kPa — —
Modulating control
VFF2FW1Y2E 2 in. DN50 61 Cv 53 kvs 144 Cv 125 kvs Spring Return 2- NEMA 2 housing 175 psi 1206 kPa — —
Position, 120 Vac
VFF2FW1YXA 2 in. DN50 61 Cv 53 kvs 144 Cv 125 kvs Non-Spring Return NEMA 4X (Water 175 psi 1206 kPa — Anti-condensation
120 Vac Floating tight, corrosion- heater, manual
control proof) housing gear wheel
VFF2FW1YXB 2 in. DN50 61 Cv 53 kvs 144 Cv 125 kvs Non-Spring Return NEMA 4X (Water 175 psi 1206 kPa — Anti-condensation
Modulating control tight, corrosion- heater, manual
proof) housing gear wheel
VFF2GW1Y2A 2-1/2 in. DN65 107 Cv 93 kvs 282 Cv 244 kvs Non-Spring Return NEMA 2 housing 175 psi 1206 kPa — —
Floating control
VFF2GW1Y2B 2-1/2 in. DN65 107 Cv 93 kvs 282 Cv 244 kvs Non-Spring Return NEMA 2 housing 175 psi 1206 kPa — —
Modulating control
VFF2GW1Y2C 2-1/2 in. DN65 107 Cv 93 kvs 282 Cv 244 kvs Spring Return 2- NEMA 2 housing 175 psi 1206 kPa — —
Position, 24 Vac
VFF2GW1Y2D 2-1/2 in. DN65 107 Cv 93 kvs 282 Cv 244 kvs Spring Return Floating/ NEMA 2 housing 175 psi 1206 kPa — —
Modulating control
VFF2GW1Y2E 2-1/2 in. DN65 107 Cv 93 kvs 282 Cv 244 kvs Spring Return 2- NEMA 2 housing 175 psi 1206 kPa — —
Position, 120 Vac
VFF2GW1YXA 2-1/2 in. DN65 107 Cv 93 kvs 282 Cv 244 kvs Non-Spring Return NEMA 4X (Water 175 psi 1206 kPa — Anti-condensation
120 Vac Floating tight, corrosion- heater, manual
control proof) housing gear wheel

606 customer.honeywell.com 70-6910


Butterfly Control Valves

Controls
Maximum

Home
Differential
Pressure
Capacity at 60 Capacity at 90 Ratings
Valve Size degrees stroke degrees stroke (Close-off)
Type of
Product Number (inch) (DN) (Cv) (Kv) (Cv) (Kv) Actuator Selection Enclosure (psi) (kPa) Comments Includes
VFF2GW1YXB 2-1/2 in. DN65 107 Cv 93 kvs 282 Cv 244 kvs Non-Spring Return NEMA 4X (Water 175 psi 1206 kPa — Anti-condensation
Modulating control tight, corrosion- heater, manual

Indoor Air Quality


proof) housing gear wheel
VFF2HW1Y2A 3 in. DN80 154 Cv 133 kvs 461 Cv 399 kvs Non-Spring Return NEMA 2 housing 175 psi 1206 kPa — —
Floating control
VFF2HW1Y2B 3 in. DN80 154 Cv 133 kvs 461 Cv 399 kvs Non-Spring Return NEMA 2 housing 175 psi 1206 kPa — —
Modulating control
VFF2HW1Y2C 3 in. DN80 154 Cv 133 kvs 461 Cv 399 kvs Spring Return 2- NEMA 2 housing 175 psi 1206 kPa — —
Position, 24 Vac
VFF2HW1Y2D 3 in. DN80 154 Cv 133 kvs 461 Cv 399 kvs Spring Return Floating/ NEMA 2 housing 175 psi 1206 kPa — —

Combustion Controls
Modulating control
VFF2HW1Y2E 3 in. DN80 154 Cv 133 kvs 461 Cv 399 kvs Spring Return 2- NEMA 2 housing 175 psi 1206 kPa — —

Residential
Position, 120 Vac
VFF2HW1YXA 3 in. DN80 154 Cv 133 kvs 461 Cv 399 kvs Non-Spring Return NEMA 4X (Water 175 psi 1206 kPa — Anti-condensation
120 Vac Floating tight, corrosion- heater, manual
control proof) housing gear wheel
VFF2HW1YXB 3 in. DN80 154 Cv 133 kvs 461 Cv 399 kvs Non-Spring Return NEMA 4X (Water 175 psi 1206 kPa — Anti-condensation
Modulating control tight, corrosion- heater, manual
proof) housing gear wheel

Hydronic Controls
VFF2JV1Y2A 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs Non-Spring Return NEMA 2 housing 50 psi 345 kPa — —
Floating control
VFF2JV1Y2B 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs Non-Spring Return NEMA 2 housing 50 psi 345 kPa — —
Modulating control
VFF2JV1Y2C 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs Spring Return 2- NEMA 2 housing 50 psi 345 kPa — —
Position, 24 Vac
VFF2JV1Y2D 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs Spring Return Floating/ NEMA 2 housing 50 psi 345 kPa — —
Modulating control
VFF2JV1Y2E 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs Spring Return 2- NEMA 2 housing 50 psi 345 kPa — —
Position, 120 Vac
VFF2JW1Y2A 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs Non-Spring Return NEMA 2 housing 175 psi 1206 kPa — —

Controls
Water
Floating control
VFF2JW1Y2B 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs Non-Spring Return NEMA 2 housing 175 psi 1206 kPa — —
Modulating control
VFF2JV1YXA 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs Non-Spring Return NEMA 4X (Water 50 psi 345 kPa — Anti-condensation
120 Vac Floating tight, corrosion- heater, manual
control proof) housing gear wheel
VFF2JV1YXB 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs Non-Spring Return NEMA 4X (Water 50 psi 345 kPa — Anti-condensation

Building Automation
Modulating control tight, corrosion- heater, manual
proof) housing gear wheel
VFF2JW1YXA 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs Non-Spring Return NEMA 4X (Water 175 psi 1206 kPa — Anti-condensation
120 Vac Floating tight, corrosion- heater, manual
control proof) housing gear wheel
VFF2JW1YXB 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs Non-Spring Return NEMA 4X (Water 175 psi 1206 kPa — Anti-condensation
Modulating control tight, corrosion- heater, manual
proof) housing gear wheel
VFF2KV1Y2A 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs Non-Spring Return NEMA 2 housing 50 psi 345 kPa Chilled water —
Floating control service only

Components
Commercial
VFF2KV1Y2B 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs Non-Spring Return NEMA 2 housing 50 psi 345 kPa Chilled water —
Modulating control service only
VFF2KV1Y2C 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs Spring Return 2- NEMA 2 housing 50 psi 345 kPa Chilled water —
Position, 24 Vac service only
VFF2KV1Y2D 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs Spring Return Floating/ NEMA 2 housing 50 psi 345 kPa Chilled water —
Modulating control service only
VFF2KV1Y2E 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs Spring Return 2- NEMA 2 housing 50 psi 345 kPa Chilled water —
Position, 120 Vac service only
Pneumatic Controls

VFF2KW1Y2A 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs Non-Spring Return NEMA 2 housing 175 psi 1206 kPa — —
Floating control
VFF2KW1Y2B 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs Non-Spring Return NEMA 2 housing 175 psi 1206 kPa — —
Modulating control
VFF2KV1YXA 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs Non-Spring Return NEMA 4X (Water 50 psi 345 kPa — Anti-condensation
120 Vac Floating tight, corrosion- heater, manual
control proof) housing gear wheel
VFF2KV1YXB 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs Non-Spring Return NEMA 4X (Water 50 psi 345 kPa — Anti-condensation
Industrial Combustion

Modulating control tight, corrosion- heater, manual


proof) housing gear wheel
VFF2KW1YXA 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs Non-Spring Return NEMA 4X (Water 175 psi 1206 kPa — Anti-condensation
Controls

120 Vac Floating tight, corrosion- heater, manual


control proof) housing gear wheel

70-6910 607
Butterfly Control Valves
Maximum
Differential
Pressure
Capacity at 60 Capacity at 90 Ratings
Valve Size degrees stroke degrees stroke (Close-off)
Type of
Product Number (inch) (DN) (Cv) (Kv) (Cv) (Kv) Actuator Selection Enclosure (psi) (kPa) Comments Includes
VFF2KW1YXB 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs Non-Spring Return NEMA 4X (Water 175 psi 1206 kPa — Anti-condensation
Modulating control tight, corrosion- heater, manual
proof) housing gear wheel
VFF2LW1Y2A 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs Non-Spring Return NEMA 2 housing 175 psi 1206 kPa — —
Floating control
VFF2LW1Y2B 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs Non-Spring Return NEMA 2 housing 175 psi 1206 kPa — —
Modulating control
VFF2LV1YXA 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs Non-Spring Return NEMA 4X (Water 50 psi 345 kPa — Anti-condensation
120 Vac Floating tight, corrosion- heater, manual
control proof) housing gear wheel
VFF2LV1YXB 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs Non-Spring Return NEMA 4X (Water 50 psi 345 kPa — Anti-condensation
Modulating control tight, corrosion- heater, manual
proof) housing gear wheel
VFF2LW1YXA 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs Non-Spring Return NEMA 4X (Water 175 psi 1206 kPa — Anti-condensation
120 Vac Floating tight, corrosion- heater, manual
control proof) housing gear wheel
VFF2LW1YXB 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs Non-Spring Return NEMA 4X (Water 175 psi 1206 kPa — Anti-condensation
Modulating control tight, corrosion- heater, manual
proof) housing gear wheel
VFF2MV1Y2A 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs Non-Spring Return NEMA 2 housing 50 psi 345 kPa — —
Floating control
VFF2MV1Y2B 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs Non-Spring Return NEMA 2 housing 50 psi 345 kPa — —
Modulating control
VFF2MV1YXA 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs Non-Spring Return NEMA 4X (Water 50 psi 345 kPa — Anti-condensation
120 Vac Floating tight, corrosion- heater, manual
control proof) housing gear wheel
VFF2MV1YXB 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs Non-Spring Return NEMA 4X (Water 50 psi 345 kPa — Anti-condensation
Modulating control tight, corrosion- heater, manual
proof) housing gear wheel
VFF2MW1YXA 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs Non-Spring Return NEMA 4X (Water 175 psi 1206 kPa — Anti-condensation
120 Vac Floating tight, corrosion- heater, manual
control proof) housing gear wheel
VFF2MW1YXB 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs Non-Spring Return NEMA 4X (Water 175 psi 1206 kPa — Anti-condensation
Modulating control tight, corrosion- heater, manual
proof) housing gear wheel
VFF2NV1YXA 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs Non-Spring Return NEMA 4X (Water 50 psi 345 kPa — Anti-condensation
120 Vac Floating tight, corrosion- heater, manual
control proof) housing gear wheel
VFF2NV1YXB 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs Non-Spring Return NEMA 4X (Water 50 psi 345 kPa — Anti-condensation
Modulating control tight, corrosion- heater, manual
proof) housing gear wheel
VFF2NW1YXA 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs Non-Spring Return NEMA 4X (Water 175 psi 1206 kPa — Anti-condensation
120 Vac Floating tight, corrosion- heater, manual
control proof) housing gear wheel
VFF2NW1YXB 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs Non-Spring Return NEMA 4X (Water 175 psi 1206 kPa — Anti-condensation
Modulating control tight, corrosion- heater, manual
proof) housing gear wheel
VFF2PV1YXA 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs Non-Spring Return NEMA 4X (Water 50 psi 345 kPa — Anti-condensation
120 Vac Floating tight, corrosion- heater, manual
control proof) housing gear wheel
VFF2PV1YXB 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs Non-Spring Return NEMA 4X (Water 50 psi 345 kPa — Anti-condensation
Modulating control tight, corrosion- heater, manual
proof) housing gear wheel
VFF2PW1YXA 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs Non-Spring Return NEMA 4X (Water 175 psi 1206 kPa — Anti-condensation
120 Vac Floating tight, corrosion- heater, manual
control proof) housing gear wheel
VFF2PW1YXB 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs Non-Spring Return NEMA 4X (Water 175 psi 1206 kPa — Anti-condensation
Modulating control tight, corrosion- heater, manual
proof) housing gear wheel
VFF2RV1YXA 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs Non-Spring Return NEMA 4X (Water 50 psi 345 kPa — Anti-condensation
120 Vac Floating tight, corrosion- heater, manual
control proof) housing gear wheel
VFF2RV1YXB 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs Non-Spring Return NEMA 4X (Water 50 psi 345 kPa — Anti-condensation
Modulating control tight, corrosion- heater, manual
proof) housing gear wheel
VFF2RW1YXA 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs Non-Spring Return NEMA 4X (Water 150 psi 1034 kPa — Anti-condensation
120 Vac Floating tight, corrosion- heater, manual
control proof) housing gear wheel

608 customer.honeywell.com 70-6910


Butterfly Control Valves

Controls
Maximum

Home
Differential
Pressure
Capacity at 60 Capacity at 90 Ratings
Valve Size degrees stroke degrees stroke (Close-off)
Type of
Product Number (inch) (DN) (Cv) (Kv) (Cv) (Kv) Actuator Selection Enclosure (psi) (kPa) Comments Includes
VFF2RW1YXB 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs Non-Spring Return NEMA 4X (Water 150 psi 1034 kPa — Anti-condensation
Modulating control tight, corrosion- heater, manual

Indoor Air Quality


proof) housing gear wheel
VFF2SW1Y4A 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs Non-Spring Return NEMA 4 (Water 150 psi 1034 kPa — Anti-condensation
120 Vac Floating tight) housing heater, manual
control gear wheel
VFF2SW1Y4B 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs Non-Spring Return 20 NEMA 4 (Water 150 psi 1034 kPa — Anti-condensation
mA Modulating control tight) housing heater, manual
gear wheel
VFF2SV1YXA 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs Non-Spring Return NEMA 4X (Water 50 psi 345 kPa — Anti-condensation

Combustion Controls
120 Vac Floating tight, corrosion- heater, manual
control proof) housing gear wheel

Residential
VFF2SV1YXB 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs Non-Spring Return NEMA 4X (Water 50 psi 345 kPa — Anti-condensation
Modulating control tight, corrosion- heater, manual
proof) housing gear wheel
VFF2TW1Y4A 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs Non-Spring Return NEMA 4 (Water 150 psi 1034 kPa — Anti-condensation
120 Vac Floating tight) housing heater, manual
control gear wheel
VFF2TW1Y4B 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs Non-Spring Return 20 NEMA 4 (Water 150 psi 1034 kPa — Anti-condensation
mA Modulating control tight) housing heater, manual

Hydronic Controls
gear wheel
VFF2TV1YXA 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs Non-Spring Return NEMA 4X (Water 50 psi 345 kPa — Anti-condensation
120 Vac Floating tight, corrosion- heater, manual
control proof) housing gear wheel
VFF2TV1YXB 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs Non-Spring Return NEMA 4X (Water 50 psi 345 kPa — Anti-condensation
Modulating control tight, corrosion- heater, manual
proof) housing gear wheel
VFF2UV1Y4A 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs Non-Spring Return NEMA 4 (Water 50 psi 345 kPa — Anti-condensation
120 Vac Floating tight) housing heater, manual
control gear wheel
VFF2UV1Y4B 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs Non-Spring Return 20 NEMA 4 (Water 50 psi 345 kPa — Anti-condensation

Controls
mA Modulating control tight) housing heater, manual

Water
gear wheel
VFF2UW1Y4A 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs Non-Spring Return NEMA 4 (Water 150 psi 1034 kPa — Anti-condensation
120 Vac Floating tight) housing heater, manual
control gear wheel
VFF2UW1Y4B 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs Non-Spring Return 20 NEMA 4 (Water 150 psi 1034 kPa — Anti-condensation
mA Modulating control tight) housing heater, manual

Building Automation
gear wheel
Valves with Pneumatic Actuator

Maximum
Differential
Pressure
Capacity at 60 Capacity at 90 Ratings
Valve Size degrees stroke degrees stroke (Close-off)
Type of
Product Number (inch) (DN) (Cv) (Kv) (Cv) (Kv) Actuator Selection Enclosure (psi) (kPa) Comments Includes
VFF2FW1Y8P 2 in. DN50 61 Cv 53 kvs Stroke limited to 70 20 psi spring return Pneumatic 175 psi 1206 kPa Linear actuator —

Components
Commercial
degrees
VFF2FW1YCR 2 in. DN50 61 Cv 53 kvs 144 Cv 125 kvs 2-position, 24 Vac solenoid Pneumatic 175 psi 1206 kPa — Position indicator
80 psi bidirectional
VFF2FW1YCS 2 in. DN50 61 Cv 53 kvs 144 Cv 125 kvs 2-position, 24 Vac solenoid Pneumatic 175 psi 1206 kPa — Position indicator
80 psi spring return
VFF2FW1YDR 2 in. DN50 61 Cv 53 kvs 144 Cv 125 kvs 4-20 mA Servo 80 psi Pneumatic 175 psi 1206 kPa — Position indicator
bidirectional
Pneumatic Controls

VFF2FW1YDS 2 in. DN50 61 Cv 53 kvs 144 Cv 125 kvs 4-20 mA Servo, 80 psi Pneumatic 175 psi 1206 kPa — Position indicator
spring return
VFF2FW1YER 2 in. DN50 61 Cv 53 kvs 144 Cv 125 kvs 2-position, 120 Vac solenoid Pneumatic 175 psi 1206 kPa — Position indicator
80 psi bidirectional
VFF2FW1YES 2 in. DN50 61 Cv 53 kvs 144 Cv 125 kvs 2-position, 120 Vac solenoid Pneumatic 175 psi 1206 kPa — Position indicator
80 psi spring return
VFF2FW1YPP 2 in. DN50 61 Cv 53 kvs Stroke limited to 70 Modulating w/positioner, Pneumatic 175 psi 1206 kPa Linear actuator —
degrees spring return
VFF2FW1YPR 2 in. DN50 61 Cv 53 kvs 144 Cv 125 kvs Modulating w/positioner, Pneumatic 175 psi 1206 kPa — Position indicator
Industrial Combustion

bidirectional
VFF2FW1YPS 2 in. DN50 61 Cv 53 kvs 144 Cv 125 kvs Modulating w/positioner, Pneumatic 175 psi 1206 kPa — Position indicator
Controls

spring return

70-6910 609
Butterfly Control Valves
Maximum
Differential
Pressure
Capacity at 60 Capacity at 90 Ratings
Valve Size degrees stroke degrees stroke (Close-off)
Type of
Product Number (inch) (DN) (Cv) (Kv) (Cv) (Kv) Actuator Selection Enclosure (psi) (kPa) Comments Includes
VFF2FW1YXR 2 in. DN50 61 Cv 53 kvs 144 Cv 125 kvs 2-position 80 psi Pneumatic 175 psi 1206 kPa — Position indicator
bidirectional
VFF2FW1YXS 2 in. DN50 61 Cv 53 kvs 144 Cv 125 kvs 2-position, 80 psi spring Pneumatic 175 psi 1206 kPa — Position indicator
return
VFF2GW1Y8P 2-1/2 in. DN65 107 Cv 93 kvs Stroke limited to 70 20 psi spring return Pneumatic 175 psi 1206 kPa Linear actuator —
degrees
VFF2GW1YCR 2-1/2 in. DN65 107 Cv 93 kvs 282 Cv 244 kvs 2-position, 24 Vac solenoid Pneumatic 175 psi 1206 kPa — Position indicator
80 psi bidirectional
VFF2GW1YCS 2-1/2 in. DN65 107 Cv 93 kvs 282 Cv 244 kvs 2-position, 24 Vac solenoid Pneumatic 175 psi 1206 kPa — Position indicator
80 psi spring return
VFF2GW1YDR 2-1/2 in. DN65 107 Cv 93 kvs 282 Cv 244 kvs 4-20 mA Servo 80 psi Pneumatic 175 psi 1206 kPa — Position indicator
bidirectional
VFF2GW1YDS 2-1/2 in. DN65 107 Cv 93 kvs 282 Cv 244 kvs 4-20 mA Servo, 80 psi Pneumatic 175 psi 1206 kPa — Position indicator
spring return
VFF2GW1YER 2-1/2 in. DN65 107 Cv 93 kvs 282 Cv 244 kvs 2-position, 120 Vac solenoid Pneumatic 175 psi 1206 kPa — Position indicator
80 psi bidirectional
VFF2GW1YES 2-1/2 in. DN65 107 Cv 93 kvs 282 Cv 244 kvs 2-position, 120 Vac solenoid Pneumatic 175 psi 1206 kPa — Position indicator
80 psi spring return
VFF2GW1YPP 2-1/2 in. DN65 107 Cv 93 kvs Stroke limited to 70 Modulating w/positioner, Pneumatic 175 psi 1206 kPa Linear actuator —
degrees spring return
VFF2GW1YPR 2-1/2 in. DN65 107 Cv 93 kvs 282 Cv 244 kvs Modulating w/positioner, Pneumatic 175 psi 1206 kPa — Position indicator
bidirectional
VFF2GW1YPS 2-1/2 in. DN65 107 Cv 93 kvs 282 Cv 244 kvs Modulating w/positioner, Pneumatic 175 psi 1206 kPa — Position indicator
spring return
VFF2GW1YXR 2-1/2 in. DN65 107 Cv 93 kvs 282 Cv 244 kvs 2-position 80 psi Pneumatic 175 psi 1206 kPa — Position indicator
bidirectional
VFF2GW1YXS 2-1/2 in. DN65 107 Cv 93 kvs 282 Cv 244 kvs 2-position, 80 psi spring Pneumatic 175 psi 1206 kPa — Position indicator
return
VFF2HW1Y8P 3 in. DN80 154 Cv 133 kvs Stroke limited to 70 20 psi spring return Pneumatic 175 psi 1206 kPa Linear actuator —
degrees
VFF2HW1YCR 3 in. DN80 154 Cv 133 kvs 461 Cv 399 kvs 2-position, 24 Vac solenoid Pneumatic 175 psi 1206 kPa — Position indicator
80 psi bidirectional
VFF2HW1YCS 3 in. DN80 154 Cv 133 kvs 461 Cv 399 kvs 2-position, 24 Vac solenoid Pneumatic 175 psi 1206 kPa — Position indicator
80 psi spring return
VFF2HW1YDR 3 in. DN80 154 Cv 133 kvs 461 Cv 399 kvs 4-20 mA Servo 80 psi Pneumatic 175 psi 1206 kPa — Position indicator
bidirectional
VFF2HW1YDS 3 in. DN80 154 Cv 133 kvs 461 Cv 399 kvs 4-20 mA Servo, 80 psi Pneumatic 175 psi 1206 kPa — Position indicator
spring return
VFF2HW1YER 3 in. DN80 154 Cv 133 kvs 461 Cv 399 kvs 2-position, 120 Vac solenoid Pneumatic 175 psi 1206 kPa — Position indicator
80 psi bidirectional
VFF2HW1YES 3 in. DN80 154 Cv 133 kvs 461 Cv 399 kvs 2-position, 120 Vac solenoid Pneumatic 175 psi 1206 kPa — Position indicator
80 psi spring return
VFF2HW1YPP 3 in. DN80 154 Cv 133 kvs Stroke limited to 70 Modulating w/positioner, Pneumatic 175 psi 1206 kPa Linear actuator —
degrees spring return
VFF2HW1YPR 3 in. DN80 154 Cv 133 kvs 461 Cv 399 kvs Modulating w/positioner, Pneumatic 175 psi 1206 kPa — Position indicator
bidirectional
VFF2HW1YPS 3 in. DN80 154 Cv 133 kvs 461 Cv 399 kvs Modulating w/positioner, Pneumatic 175 psi 1206 kPa — Position indicator
spring return
VFF2HW1YXR 3 in. DN80 154 Cv 133 kvs 461 Cv 399 kvs 2-position 80 psi Pneumatic 175 psi 1206 kPa — Position indicator
bidirectional
VFF2HW1YXS 3 in. DN80 154 Cv 133 kvs 461 Cv 399 kvs 2-position, 80 psi spring Pneumatic 175 psi 1206 kPa — Position indicator
return
VFF2JV1Y8P 4 in. DN100 274 Cv 237 kvs Stroke limited to 70 20 psi spring return Pneumatic 50 psi 345 kPa Linear actuator —
degrees
VFF2JV1YCR 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs 2-position, 24 Vac solenoid Pneumatic 50 psi 345 kPa — Position indicator
80 psi bidirectional
VFF2JV1YCS 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs 2-position, 24 Vac solenoid Pneumatic 50 psi 345 kPa — Position indicator
80 psi spring return
VFF2JV1YDR 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs 4-20 mA Servo 80 psi Pneumatic 50 psi 345 kPa — Position indicator
bidirectional
VFF2JV1YDS 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs 4-20 mA Servo, 80 psi Pneumatic 50 psi 345 kPa — Position indicator
spring return
VFF2JV1YER 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs 2-position, 120 Vac solenoid Pneumatic 50 psi 345 kPa — Position indicator
80 psi bidirectional
VFF2JV1YES 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs 2-position, 120 Vac solenoid Pneumatic 50 psi 345 kPa — Position indicator
80 psi spring return

610 customer.honeywell.com 70-6910


Butterfly Control Valves

Controls
Maximum

Home
Differential
Pressure
Capacity at 60 Capacity at 90 Ratings
Valve Size degrees stroke degrees stroke (Close-off)
Type of
Product Number (inch) (DN) (Cv) (Kv) (Cv) (Kv) Actuator Selection Enclosure (psi) (kPa) Comments Includes
VFF2JV1YPP 4 in. DN100 274 Cv 237 kvs Stroke limited to 70 Modulating w/positioner, Pneumatic 50 psi 345 kPa Linear actuator —
degrees spring return

Indoor Air Quality


VFF2JV1YPR 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs Modulating w/positioner, Pneumatic 50 psi 345 kPa — Position indicator
bidirectional
VFF2JV1YPS 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs Modulating w/positioner, Pneumatic 50 psi 345 kPa — Position indicator
spring return
VFF2JV1YXR 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs 2-position 80 psi Pneumatic 50 psi 345 kPa — Position indicator
bidirectional
VFF2JV1YXS 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs 2-position, 80 psi spring Pneumatic 50 psi 345 kPa — Position indicator
return

Combustion Controls
VFF2JW1Y8P 4 in. DN100 274 Cv 237 kvs Stroke limited to 70 20 psi spring return Pneumatic 175 psi 1206 kPa Linear actuator —
degrees

Residential
VFF2JW1YCR 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs 2-position, 24 Vac solenoid Pneumatic 175 psi 1206 kPa — Position indicator
80 psi bidirectional
VFF2JW1YCS 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs 2-position, 24 Vac solenoid Pneumatic 175 psi 1206 kPa — Position indicator
80 psi spring return
VFF2JW1YDR 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs 4-20 mA Servo 80 psi Pneumatic 175 psi 1206 kPa — Position indicator
bidirectional
VFF2JW1YDS 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs 4-20 mA Servo, 80 psi Pneumatic 175 psi 1206 kPa — Position indicator

Hydronic Controls
spring return
VFF2JW1YER 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs 2-position, 120 Vac solenoid Pneumatic 175 psi 1206 kPa — Position indicator
80 psi bidirectional
VFF2JW1YES 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs 2-position, 120 Vac solenoid Pneumatic 175 psi 1206 kPa — Position indicator
80 psi spring return
VFF2JW1YPP 4 in. DN100 274 Cv 237 kvs Stroke limited to 70 Modulating w/positioner, Pneumatic 175 psi 1206 kPa Linear actuator —
degrees spring return
VFF2JW1YPR 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs Modulating w/positioner, Pneumatic 175 psi 1206 kPa — Position indicator
bidirectional
VFF2JW1YPS 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs Modulating w/positioner, Pneumatic 175 psi 1206 kPa — Position indicator

Controls
spring return

Water
VFF2JW1YXR 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs 2-position 80 psi Pneumatic 175 psi 1206 kPa — Position indicator
bidirectional
VFF2JW1YXS 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs 2-position, 80 psi spring Pneumatic 175 psi 1206 kPa — Position indicator
return
VFF2KV1Y8P 5 in. DN125 428 Cv 370 kvs Stroke limited to 70 20 psi spring return Pneumatic 50 psi 345 kPa Linear actuator —
degrees

Building Automation
VFF2KV1YCR 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs 2-position, 24 Vac solenoid Pneumatic 50 psi 345 kPa — Position indicator
80 psi bidirectional
VFF2KV1YCS 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs 2-position, 24 Vac solenoid Pneumatic 50 psi 345 kPa — Position indicator
80 psi spring return
VFF2KV1YDR 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs 4-20 mA Servo 80 psi Pneumatic 50 psi 345 kPa — Position indicator
bidirectional
VFF2KV1YDS 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs 4-20 mA Servo, 80 psi Pneumatic 50 psi 345 kPa — Position indicator
spring return
VFF2KV1YER 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs 2-position, 120 Vac solenoid Pneumatic 50 psi 345 kPa — Position indicator
80 psi bidirectional

Components
Commercial
VFF2KV1YES 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs 2-position, 120 Vac solenoid Pneumatic 50 psi 345 kPa — Position indicator
80 psi spring return
VFF2KV1YPP 5 in. DN125 428 Cv 370 kvs Stroke limited to 70 Modulating w/positioner, Pneumatic 50 psi 345 kPa Linear actuator —
degrees spring return
VFF2KV1YPR 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs Modulating w/positioner, Pneumatic 50 psi 345 kPa — Position indicator
bidirectional
VFF2KV1YPS 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs Modulating w/positioner, Pneumatic 50 psi 345 kPa — Position indicator
spring return
Pneumatic Controls

VFF2KV1YXR 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs 2-position 80 psi Pneumatic 50 psi 345 kPa — Position indicator
bidirectional
VFF2KV1YXS 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs 2-position, 80 psi spring Pneumatic 50 psi 345 kPa — Position indicator
return
VFF2KW1Y8P 5 in. DN125 428 Cv 370 kvs Stroke limited to 70 20 psi spring return Pneumatic 175 psi 1206 kPa Linear actuator —
degrees
VFF2KW1YCR 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs 2-position, 24 Vac solenoid Pneumatic 175 psi 1206 kPa — Position indicator
80 psi bidirectional
Industrial Combustion

VFF2KW1YCS 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs 2-position, 24 Vac solenoid Pneumatic 175 psi 1206 kPa — Position indicator
80 psi spring return
Controls

VFF2KW1YDR 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs 4-20 mA Servo 80 psi Pneumatic 175 psi 1206 kPa — Position indicator
bidirectional

70-6910 611
Butterfly Control Valves
Maximum
Differential
Pressure
Capacity at 60 Capacity at 90 Ratings
Valve Size degrees stroke degrees stroke (Close-off)
Type of
Product Number (inch) (DN) (Cv) (Kv) (Cv) (Kv) Actuator Selection Enclosure (psi) (kPa) Comments Includes
VFF2KW1YDS 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs 4-20 mA Servo, 80 psi Pneumatic 175 psi 1206 kPa — Position indicator
spring return
VFF2KW1YER 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs 2-position, 120 Vac solenoid Pneumatic 175 psi 1206 kPa — Position indicator
80 psi bidirectional
VFF2KW1YES 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs 2-position, 120 Vac solenoid Pneumatic 175 psi 1206 kPa — Position indicator
80 psi spring return
VFF2KW1YPP 5 in. DN125 428 Cv 370 kvs Stroke limited to 70 Modulating w/positioner, Pneumatic 175 psi 1206 kPa Linear actuator —
degrees spring return
VFF2KW1YPR 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs Modulating w/positioner, Pneumatic 175 psi 1206 kPa — Position indicator
bidirectional
VFF2KW1YPS 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs Modulating w/positioner, Pneumatic 175 psi 1206 kPa — Position indicator
spring return
VFF2KW1YXR 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs 2-position 80 psi Pneumatic 175 psi 1206 kPa — Position indicator
bidirectional
VFF2KW1YXS 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs 2-position, 80 psi spring Pneumatic 175 psi 1206 kPa — Position indicator
return
VFF2LV1YCR 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs 2-position, 24 Vac solenoid Pneumatic 50 psi 345 kPa — Position indicator
80 psi bidirectional
VFF2LV1YCS 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs 2-position, 24 Vac solenoid Pneumatic 50 psi 345 kPa — Position indicator
80 psi spring return
VFF2LV1YDR 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs 4-20 mA Servo 80 psi Pneumatic 50 psi 345 kPa — Position indicator
bidirectional
VFF2LV1YDS 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs 4-20 mA Servo, 80 psi Pneumatic 50 psi 345 kPa — Position indicator
spring return
VFF2LV1YER 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs 2-position, 120 Vac solenoid Pneumatic 50 psi 345 kPa — Position indicator
80 psi bidirectional
VFF2LV1YES 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs 2-position, 120 Vac solenoid Pneumatic 50 psi 345 kPa — Position indicator
80 psi spring return
VFF2LV1YPR 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs Modulating w/positioner, Pneumatic 50 psi 345 kPa — Position indicator
bidirectional
VFF2LV1YPS 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs Modulating w/positioner, Pneumatic 50 psi 345 kPa — Position indicator
spring return
VFF2LV1YXR 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs 2-position 80 psi Pneumatic 50 psi 345 kPa — Position indicator
bidirectional
VFF2LV1YXS 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs 2-position, 80 psi spring Pneumatic 50 psi 345 kPa — Position indicator
return
VFF2LW1Y8P 6 in. DN150 567 Cv 490 kvs Stroke limited to 70 20 psi spring return Pneumatic 175 psi 1206 kPa Linear actuator —
degrees
VFF2LW1YCR 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs 2-position, 24 Vac solenoid Pneumatic 175 psi 1206 kPa — Position indicator
80 psi bidirectional
VFF2LW1YCS 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs 2-position, 24 Vac solenoid Pneumatic 175 psi 1206 kPa — Position indicator
80 psi spring return
VFF2LW1YDR 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs 4-20 mA Servo 80 psi Pneumatic 175 psi 1206 kPa — Position indicator
bidirectional
VFF2LW1YDS 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs 4-20 mA Servo, 80 psi Pneumatic 175 psi 1206 kPa — Position indicator
spring return
VFF2LW1YER 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs 2-position, 120 Vac solenoid Pneumatic 175 psi 1206 kPa — Position indicator
80 psi bidirectional
VFF2LW1YES 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs 2-position, 120 Vac solenoid Pneumatic 175 psi 1206 kPa — Position indicator
80 psi spring return
VFF2LW1YPP 6 in. DN150 567 Cv 490 kvs Stroke limited to 70 Modulating w/positioner, Pneumatic 175 psi 1206 kPa Linear actuator —
degrees spring return
VFF2LW1YPR 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs Modulating w/positioner, Pneumatic 175 psi 1206 kPa — Position indicator
bidirectional
VFF2LW1YPS 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs Modulating w/positioner, Pneumatic 175 psi 1206 kPa — Position indicator
spring return
VFF2LW1YXR 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs 2-position 80 psi Pneumatic 175 psi 1206 kPa — Position indicator
bidirectional
VFF2LW1YXS 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs 2-position, 80 psi spring Pneumatic 175 psi 1206 kPa — Position indicator
return
VFF2MV1Y8P 8 in. DN200 1081 Cv 935 kvs Stroke limited to 70 20 psi spring return Pneumatic 50 psi 345 kPa Linear actuator —
degrees
VFF2MV1YCR 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs 2-position, 24 Vac solenoid Pneumatic 50 psi 345 kPa — Position indicator
80 psi bidirectional
VFF2MV1YCS 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs 2-position, 24 Vac solenoid Pneumatic 50 psi 345 kPa — Position indicator
80 psi spring return

612 customer.honeywell.com 70-6910


Butterfly Control Valves

Controls
Maximum

Home
Differential
Pressure
Capacity at 60 Capacity at 90 Ratings
Valve Size degrees stroke degrees stroke (Close-off)
Type of
Product Number (inch) (DN) (Cv) (Kv) (Cv) (Kv) Actuator Selection Enclosure (psi) (kPa) Comments Includes
VFF2MV1YDR 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs 4-20 mA Servo 80 psi Pneumatic 50 psi 345 kPa — Position indicator
bidirectional

Indoor Air Quality


VFF2MV1YDS 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs 4-20 mA Servo, 80 psi Pneumatic 50 psi 345 kPa — Position indicator
spring return
VFF2MV1YER 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs 2-position, 120 Vac solenoid Pneumatic 50 psi 345 kPa — Position indicator
80 psi bidirectional
VFF2MV1YES 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs 2-position, 120 Vac solenoid Pneumatic 50 psi 345 kPa — Position indicator
80 psi spring return
VFF2MV1YPP 8 in. DN200 1081 Cv 935 kvs Stroke limited to 70 Modulating w/positioner, Pneumatic 50 psi 345 kPa Linear actuator —
degrees spring return

Combustion Controls
VFF2MV1YPR 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs Modulating w/positioner, Pneumatic 50 psi 345 kPa — Position indicator
bidirectional

Residential
VFF2MV1YPS 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs Modulating w/positioner, Pneumatic 50 psi 345 kPa — Position indicator
spring return
VFF2MV1YXR 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs 2-position 80 psi Pneumatic 50 psi 345 kPa — Position indicator
bidirectional
VFF2MV1YXS 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs 2-position, 80 psi spring Pneumatic 50 psi 345 kPa — Position indicator
return
VFF2MW1Y8P 8 in. DN200 1081 Cv 935 kvs Stroke limited to 70 20 psi spring return Pneumatic 175 psi 1206 kPa Linear actuator —

Hydronic Controls
degrees
VFF2MW1YCR 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs 2-position, 24 Vac solenoid Pneumatic 175 psi 1206 kPa — Position indicator
80 psi bidirectional
VFF2MW1YCS 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs 2-position, 24 Vac solenoid Pneumatic 175 psi 1206 kPa — Position indicator
80 psi spring return
VFF2MW1YDR 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs 4-20 mA Servo 80 psi Pneumatic 175 psi 1206 kPa — Position indicator
bidirectional
VFF2MW1YDS 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs 4-20 mA Servo, 80 psi Pneumatic 175 psi 1206 kPa — Position indicator
spring return
VFF2MW1YER 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs 2-position, 120 Vac solenoid Pneumatic 175 psi 1206 kPa — Position indicator

Controls
80 psi bidirectional

Water
VFF2MW1YES 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs 2-position, 120 Vac solenoid Pneumatic 175 psi 1206 kPa — Position indicator
80 psi spring return
VFF2MW1YPP 8 in. DN200 1081 Cv 935 kvs Stroke limited to 70 Modulating w/positioner, Pneumatic 175 psi 1206 kPa Linear actuator —
degrees spring return
VFF2MW1YPR 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs Modulating w/positioner, Pneumatic 175 psi 1206 kPa — Position indicator
bidirectional

Building Automation
VFF2MW1YPS 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs Modulating w/positioner, Pneumatic 175 psi 1206 kPa — Position indicator
spring return
VFF2MW1YXR 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs 2-position 80 psi Pneumatic 175 psi 1206 kPa — Position indicator
bidirectional
VFF2MW1YXS 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs 2-position, 80 psi spring Pneumatic 175 psi 1206 kPa — Position indicator
return
VFF2NV1Y8P 10 in. DN250 1710 Cv 1479 kvs Stroke limited to 70 20 psi spring return Pneumatic 50 psi 345 kPa Linear actuator —
degrees
VFF2NV1YCR 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs 2-position, 24 Vac solenoid Pneumatic 50 psi 345 kPa — Position indicator
80 psi bidirectional

Components
Commercial
VFF2NV1YCS 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs 2-position, 24 Vac solenoid Pneumatic 50 psi 345 kPa — Position indicator
80 psi spring return
VFF2NV1YDR 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs 4-20 mA Servo 80 psi Pneumatic 50 psi 345 kPa — Position indicator
bidirectional
VFF2NV1YDS 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs 4-20 mA Servo, 80 psi Pneumatic 50 psi 345 kPa — Position indicator
spring return
VFF2NV1YER 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs 2-position, 120 Vac solenoid Pneumatic 50 psi 345 kPa — Position indicator
80 psi bidirectional
Pneumatic Controls

VFF2NV1YES 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs 2-position, 120 Vac solenoid Pneumatic 50 psi 345 kPa — Position indicator
80 psi spring return
VFF2NV1YPP 10 in. DN250 1710 Cv 1479 kvs Stroke limited to 70 Modulating w/positioner, Pneumatic 50 psi 345 kPa Linear actuator —
degrees spring return
VFF2NV1YPR 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs Modulating w/positioner, Pneumatic 50 psi 345 kPa — Position indicator
bidirectional
VFF2NV1YPS 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs Modulating w/positioner, Pneumatic 50 psi 345 kPa — Position indicator
spring return
Industrial Combustion

VFF2NV1YXR 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs 2-position 80 psi Pneumatic 50 psi 345 kPa — Position indicator
bidirectional
Controls

VFF2NV1YXS 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs 2-position, 80 psi spring Pneumatic 50 psi 345 kPa — Position indicator
return

70-6910 613
Butterfly Control Valves
Maximum
Differential
Pressure
Capacity at 60 Capacity at 90 Ratings
Valve Size degrees stroke degrees stroke (Close-off)
Type of
Product Number (inch) (DN) (Cv) (Kv) (Cv) (Kv) Actuator Selection Enclosure (psi) (kPa) Comments Includes
VFF2NW1YCR 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs 2-position, 24 Vac solenoid Pneumatic 175 psi 1206 kPa — Position indicator
80 psi bidirectional
VFF2NW1YCS 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs 2-position, 24 Vac solenoid Pneumatic 175 psi 1206 kPa — Position indicator
80 psi spring return
VFF2NW1YDR 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs 4-20 mA Servo 80 psi Pneumatic 175 psi 1206 kPa — Position indicator
bidirectional
VFF2NW1YDS 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs 4-20 mA Servo, 80 psi Pneumatic 175 psi 1206 kPa — Position indicator
spring return
VFF2NW1YER 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs 2-position, 120 Vac solenoid Pneumatic 175 psi 1206 kPa — Position indicator
80 psi bidirectional
VFF2NW1YES 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs 2-position, 120 Vac solenoid Pneumatic 175 psi 1206 kPa — Position indicator
80 psi spring return
VFF2NW1YPR 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs Modulating w/positioner, Pneumatic 175 psi 1206 kPa — Position indicator
bidirectional
VFF2NW1YPS 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs Modulating w/positioner, Pneumatic 175 psi 1206 kPa — Position indicator
spring return
VFF2NW1YXR 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs 2-position 80 psi Pneumatic 175 psi 1206 kPa — Position indicator
bidirectional
VFF2NW1YXS 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs 2-position, 80 psi spring Pneumatic 175 psi 1206 kPa — Position indicator
return
VFF2PV1YCR 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs 2-position, 24 Vac solenoid Pneumatic 50 psi 345 kPa — Position indicator
80 psi bidirectional
VFF2PV1YCS 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs 2-position, 24 Vac solenoid Pneumatic 50 psi 345 kPa — Position indicator
80 psi spring return
VFF2PV1YDR 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs 4-20 mA Servo 80 psi Pneumatic 50 psi 345 kPa — Position indicator
bidirectional
VFF2PV1YDS 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs 4-20 mA Servo, 80 psi Pneumatic 50 psi 345 kPa — Position indicator
spring return
VFF2PV1YER 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs 2-position, 120 Vac solenoid Pneumatic 50 psi 345 kPa — Position indicator
80 psi bidirectional
VFF2PV1YES 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs 2-position, 120 Vac solenoid Pneumatic 50 psi 345 kPa — Position indicator
80 psi spring return
VFF2PV1YPR 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs Modulating w/positioner, Pneumatic 50 psi 345 kPa — Position indicator
bidirectional
VFF2PV1YPS 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs Modulating w/positioner, Pneumatic 50 psi 345 kPa — Position indicator
spring return
VFF2PV1YXR 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs 2-position 80 psi Pneumatic 50 psi 345 kPa — Position indicator
bidirectional
VFF2PV1YXS 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs 2-position, 80 psi spring Pneumatic 50 psi 345 kPa — Position indicator
return
VFF2PW1YCR 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs 2-position, 24 Vac solenoid Pneumatic 175 psi 1206 kPa — Position indicator
80 psi bidirectional
VFF2PW1YCS 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs 2-position, 24 Vac solenoid Pneumatic 175 psi 1206 kPa — Position indicator
80 psi spring return
VFF2PW1YDR 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs 4-20 mA Servo 80 psi Pneumatic 175 psi 1206 kPa — Position indicator
bidirectional
VFF2PW1YDS 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs 4-20 mA Servo, 80 psi Pneumatic 175 psi 1206 kPa — Position indicator
spring return
VFF2PW1YER 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs 2-position, 120 Vac solenoid Pneumatic 175 psi 1206 kPa — Position indicator
80 psi bidirectional
VFF2PW1YES 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs 2-position, 120 Vac solenoid Pneumatic 175 psi 1206 kPa — Position indicator
80 psi spring return
VFF2PW1YPR 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs Modulating w/positioner, Pneumatic 175 psi 1206 kPa — Position indicator
bidirectional
VFF2PW1YPS 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs Modulating w/positioner, Pneumatic 175 psi 1206 kPa — Position indicator
spring return
VFF2PW1YXR 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs 2-position 80 psi Pneumatic 175 psi 1206 kPa — Position indicator
bidirectional
VFF2PW1YXS 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs 2-position, 80 psi spring Pneumatic 175 psi 1206 kPa — Position indicator
return
VFF2RV1YCR 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs 2-position, 24 Vac solenoid Pneumatic 50 psi 345 kPa — Position indicator
80 psi bidirectional
VFF2RV1YCS 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs 2-position, 24 Vac solenoid Pneumatic 50 psi 345 kPa — Position indicator
80 psi spring return
VFF2RV1YDR 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs 4-20 mA Servo 80 psi Pneumatic 50 psi 345 kPa — Position indicator
bidirectional

614 customer.honeywell.com 70-6910


Butterfly Control Valves

Controls
Maximum

Home
Differential
Pressure
Capacity at 60 Capacity at 90 Ratings
Valve Size degrees stroke degrees stroke (Close-off)
Type of
Product Number (inch) (DN) (Cv) (Kv) (Cv) (Kv) Actuator Selection Enclosure (psi) (kPa) Comments Includes
VFF2RV1YDS 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs 4-20 mA Servo, 80 psi Pneumatic 50 psi 345 kPa — Position indicator
spring return

Indoor Air Quality


VFF2RV1YER 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs 2-position, 120 Vac solenoid Pneumatic 50 psi 345 kPa — Position indicator
80 psi bidirectional
VFF2RV1YES 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs 2-position, 120 Vac solenoid Pneumatic 50 psi 345 kPa — Position indicator
80 psi spring return
VFF2RV1YPR 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs Modulating w/positioner, Pneumatic 50 psi 345 kPa — Position indicator
bidirectional
VFF2RV1YPS 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs Modulating w/positioner, Pneumatic 50 psi 345 kPa — Position indicator
spring return

Combustion Controls
VFF2RV1YXR 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs 2-position 80 psi Pneumatic 50 psi 345 kPa — Position indicator
bidirectional

Residential
VFF2RV1YXS 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs 2-position, 80 psi spring Pneumatic 50 psi 345 kPa — Position indicator
return
VFF2RW1YCR 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs 2-position, 24 Vac solenoid Pneumatic 150 psi 1034 kPa — Position indicator
80 psi bidirectional
VFF2RW1YCS 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs 2-position, 24 Vac solenoid Pneumatic 150 psi 1034 kPa — Position indicator
80 psi spring return
VFF2RW1YDR 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs 4-20 mA Servo 80 psi Pneumatic 150 psi 1034 kPa — Position indicator

Hydronic Controls
bidirectional
VFF2RW1YDS 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs 4-20 mA Servo, 80 psi Pneumatic 150 psi 1034 kPa — Position indicator
spring return
VFF2RW1YER 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs 2-position, 120 Vac solenoid Pneumatic 150 psi 1034 kPa — Position indicator
80 psi bidirectional
VFF2RW1YES 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs 2-position, 120 Vac solenoid Pneumatic 150 psi 1034 kPa — Position indicator
80 psi spring return
VFF2RW1YPR 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs Modulating w/positioner, Pneumatic 150 psi 1034 kPa — Position indicator
bidirectional
VFF2RW1YPS 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs Modulating w/positioner, Pneumatic 150 psi 1034 kPa — Position indicator

Controls
spring return

Water
VFF2RW1YXR 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs 2-position 80 psi Pneumatic 150 psi 1034 kPa — Position indicator
bidirectional
VFF2RW1YXS 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs 2-position, 80 psi spring Pneumatic 150 psi 1034 kPa — Position indicator
return
VFF2SV1YCR 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs 2-position, 24 Vac solenoid Pneumatic 50 psi 345 kPa — Position indicator
80 psi bidirectional

Building Automation
VFF2SV1YCS 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs 2-position, 24 Vac solenoid Pneumatic 50 psi 345 kPa — Position indicator
80 psi spring return
VFF2SV1YDR 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs 4-20 mA Servo 80 psi Pneumatic 50 psi 345 kPa — Position indicator
bidirectional
VFF2SV1YDS 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs 4-20 mA Servo, 80 psi Pneumatic 50 psi 345 kPa — Position indicator
spring return
VFF2SV1YER 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs 2-position, 120 Vac solenoid Pneumatic 50 psi 345 kPa — Position indicator
80 psi bidirectional
VFF2SV1YES 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs 2-position, 120 Vac solenoid Pneumatic 50 psi 345 kPa — Position indicator
80 psi spring return

Components
Commercial
VFF2SV1YPR 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs Modulating w/positioner, Pneumatic 50 psi 345 kPa — Position indicator
bidirectional
VFF2SV1YPS 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs Modulating w/positioner, Pneumatic 50 psi 345 kPa — Position indicator
spring return
VFF2SV1YXR 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs 2-position 80 psi Pneumatic 50 psi 345 kPa — Position indicator
bidirectional
VFF2SV1YXS 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs 2-position, 80 psi spring Pneumatic 50 psi 345 kPa — Position indicator
return
Pneumatic Controls

VFF2SW1YCR 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs 2-position, 24 Vac solenoid Pneumatic 150 psi 1034 kPa — Position indicator
80 psi bidirectional
VFF2SW1YCS 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs 2-position, 24 Vac solenoid Pneumatic 150 psi 1034 kPa — Position indicator
80 psi spring return
VFF2SW1YDR 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs 4-20 mA Servo 80 psi Pneumatic 150 psi 1034 kPa — Position indicator
bidirectional
VFF2SW1YDS 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs 4-20 mA Servo, 80 psi Pneumatic 150 psi 1034 kPa — Position indicator
spring return
Industrial Combustion

VFF2SW1YER 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs 2-position, 120 Vac solenoid Pneumatic 150 psi 1034 kPa — Position indicator
80 psi bidirectional
Controls

VFF2SW1YES 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs 2-position, 120 Vac solenoid Pneumatic 150 psi 1034 kPa — Position indicator
80 psi spring return

70-6910 615
Butterfly Control Valves
Maximum
Differential
Pressure
Capacity at 60 Capacity at 90 Ratings
Valve Size degrees stroke degrees stroke (Close-off)
Type of
Product Number (inch) (DN) (Cv) (Kv) (Cv) (Kv) Actuator Selection Enclosure (psi) (kPa) Comments Includes
VFF2SW1YPR 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs Modulating w/positioner, Pneumatic 150 psi 1034 kPa — Position indicator
bidirectional
VFF2SW1YPS 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs Modulating w/positioner, Pneumatic 150 psi 1034 kPa — Position indicator
spring return
VFF2SW1YXR 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs 2-position 80 psi Pneumatic 150 psi 1034 kPa — Position indicator
bidirectional
VFF2SW1YXS 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs 2-position, 80 psi spring Pneumatic 150 psi 1034 kPa — Position indicator
return
VFF2TV1YCR 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs 2-position, 24 Vac solenoid Pneumatic 50 psi 345 kPa — Position indicator
80 psi bidirectional
VFF2TV1YCS 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs 2-position, 24 Vac solenoid Pneumatic 50 psi 345 kPa — Position indicator
80 psi spring return
VFF2TV1YDR 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs 4-20 mA Servo 80 psi Pneumatic 50 psi 345 kPa — Position indicator
bidirectional
VFF2TV1YDS 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs 4-20 mA Servo, 80 psi Pneumatic 50 psi 345 kPa — Position indicator
spring return
VFF2TV1YER 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs 2-position, 120 Vac solenoid Pneumatic 50 psi 345 kPa — Position indicator
80 psi bidirectional
VFF2TV1YES 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs 2-position, 120 Vac solenoid Pneumatic 50 psi 345 kPa — Position indicator
80 psi spring return
VFF2TV1YPR 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs Modulating w/positioner, Pneumatic 50 psi 345 kPa — Position indicator
bidirectional
VFF2TV1YPS 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs Modulating w/positioner, Pneumatic 50 psi 345 kPa — Position indicator
spring return
VFF2TV1YXR 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs 2-position 80 psi Pneumatic 50 psi 345 kPa — Position indicator
bidirectional
VFF2TV1YXS 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs 2-position, 80 psi spring Pneumatic 50 psi 345 kPa — Position indicator
return
VFF2TW1YCR 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs 2-position, 24 Vac solenoid Pneumatic 150 psi 1034 kPa — Position indicator
80 psi bidirectional
VFF2TW1YCS 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs 2-position, 24 Vac solenoid Pneumatic 150 psi 1034 kPa — Position indicator
80 psi spring return
VFF2TW1YDR 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs 4-20 mA Servo 80 psi Pneumatic 150 psi 1034 kPa — Position indicator
bidirectional
VFF2TW1YDS 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs 4-20 mA Servo, 80 psi Pneumatic 150 psi 1034 kPa — Position indicator
spring return
VFF2TW1YER 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs 2-position, 120 Vac solenoid Pneumatic 150 psi 1034 kPa — Position indicator
80 psi bidirectional
VFF2TW1YES 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs 2-position, 120 Vac solenoid Pneumatic 150 psi 1034 kPa — Position indicator
80 psi spring return
VFF2TW1YPR 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs Modulating w/positioner, Pneumatic 150 psi 1034 kPa — Position indicator
bidirectional
VFF2TW1YPS 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs Modulating w/positioner, Pneumatic 150 psi 1034 kPa — Position indicator
spring return
VFF2TW1YXR 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs 2-position 80 psi Pneumatic 150 psi 1034 kPa — Position indicator
bidirectional
VFF2TW1YXS 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs 2-position, 80 psi spring Pneumatic 150 psi 1034 kPa — Position indicator
return
VFF2UV1YCR 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs 2-position, 24 Vac solenoid Pneumatic 50 psi 345 kPa — Position indicator
80 psi bidirectional
VFF2UV1YCS 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs 2-position, 24 Vac solenoid Pneumatic 50 psi 345 kPa — Position indicator
80 psi spring return
VFF2UV1YDR 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs 4-20 mA Servo 80 psi Pneumatic 50 psi 345 kPa — Position indicator
bidirectional
VFF2UV1YDS 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs 4-20 mA Servo, 80 psi Pneumatic 50 psi 345 kPa — Position indicator
spring return
VFF2UV1YER 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs 2-position, 120 Vac solenoid Pneumatic 50 psi 345 kPa — Position indicator
80 psi bidirectional
VFF2UV1YES 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs 2-position, 120 Vac solenoid Pneumatic 50 psi 345 kPa — Position indicator
80 psi spring return
VFF2UV1YPR 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs Modulating w/positioner, Pneumatic 50 psi 345 kPa — Position indicator
bidirectional
VFF2UV1YPS 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs Modulating w/positioner, Pneumatic 50 psi 345 kPa — Position indicator
spring return
VFF2UV1YXR 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs 2-position 80 psi Pneumatic 50 psi 345 kPa — Position indicator
bidirectional

616 customer.honeywell.com 70-6910


Butterfly Control Valves

Controls
Maximum

Home
Differential
Pressure
Capacity at 60 Capacity at 90 Ratings
Valve Size degrees stroke degrees stroke (Close-off)
Type of
Product Number (inch) (DN) (Cv) (Kv) (Cv) (Kv) Actuator Selection Enclosure (psi) (kPa) Comments Includes
VFF2UV1YXS 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs 2-position, 80 psi spring Pneumatic 50 psi 345 kPa — Position indicator
return

Indoor Air Quality


VFF2UW1YCR 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs 2-position, 24 Vac solenoid Pneumatic 150 psi 1034 kPa — Position indicator
80 psi bidirectional
VFF2UW1YCS 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs 2-position, 24 Vac solenoid Pneumatic 150 psi 1034 kPa — Position indicator
80 psi spring return
VFF2UW1YDR 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs 4-20 mA Servo 80 psi Pneumatic 150 psi 1034 kPa — Position indicator
bidirectional
VFF2UW1YDS 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs 4-20 mA Servo, 80 psi Pneumatic 150 psi 1034 kPa — Position indicator
spring return

Combustion Controls
VFF2UW1YER 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs 2-position, 120 Vac solenoid Pneumatic 150 psi 1034 kPa — Position indicator
80 psi bidirectional

Residential
VFF2UW1YES 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs 2-position, 120 Vac solenoid Pneumatic 150 psi 1034 kPa — Position indicator
80 psi spring return
VFF2UW1YPR 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs Modulating w/positioner, Pneumatic 150 psi 1034 kPa — Position indicator
bidirectional
VFF2UW1YPS 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs Modulating w/positioner, Pneumatic 150 psi 1034 kPa — Position indicator
spring return
VFF2UW1YXR 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs 2-position 80 psi Pneumatic 150 psi 1034 kPa — Position indicator

Hydronic Controls
bidirectional
VFF2UW1YXS 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs 2-position, 80 psi spring Pneumatic 150 psi 1034 kPa — Position indicator
return
Valves with Manual Operators
NOTE: These products use over-cut disks to achieve 250 psid close-off, and cannot be automated due to their high torque

Maximum Differential
Capacity at 60 degrees Capacity at 90 degrees Pressure Ratings
Valve Size stroke stroke (Close-off)
Product Number (inch) (DN) (Cv) (Kv) (Cv) (Kv) (psi) (kPa) Includes

Controls
Water
VFF2FW2YGX 2 in. DN50 61 Cv 53 kvs 144 Cv 125 kvs 175 psi 1206 kPa Geared wheel operator
VFF2FW2YLX 2 in. DN50 61 Cv 53 kvs 144 Cv 125 kvs 175 psi 1206 kPa Lever operator
VFF2GW2YGX 2-1/2 in. DN65 107 Cv 93 kvs 282 Cv 244 kvs 175 psi 1206 kPa Geared wheel operator
VFF2GW2YLX 2-1/2 in. DN65 107 Cv 93 kvs 282 Cv 244 kvs 175 psi 1206 kPa Lever operator
VFF2HW2YGX 3 in. DN80 154 Cv 133 kvs 461 Cv 399 kvs 175 psi 1206 kPa Geared wheel operator

Building Automation
VFF2HW2YLX 3 in. DN80 154 Cv 133 kvs 461 Cv 399 kvs 175 psi 1206 kPa Lever operator
VFF2JW2YGX 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs 175 psi 1206 kPa Geared wheel operator
VFF2JW2YLX 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs 175 psi 1206 kPa Lever operator
VFF2KW2YGX 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs 175 psi 1206 kPa Geared wheel operator
VFF2KW2YLX 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs 175 psi 1206 kPa Lever operator
VFF2LW2YGX 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs 175 psi 1206 kPa Geared wheel operator
VFF2LW2YLX 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs 175 psi 1206 kPa Lever operator
VFF2MW2YGX 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs 175 psi 1206 kPa Geared wheel operator

Components
Commercial
VFF2MW2YLX 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs 175 psi 1206 kPa Lever operator
VFF2NW2YGX 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs 175 psi 1206 kPa Geared wheel operator
VFF2NW2YLX 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs 175 psi 1206 kPa Lever operator
VFF2PW2YGX 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs 175 psi 1206 kPa Geared wheel operator
VFF2RW2YGX 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs 150 psi 1034 kPa Geared wheel operator
Pneumatic Controls

VFF2SW2YGX 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs 150 psi 1034 kPa Geared wheel operator
VFF2TW2YGX 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs 150 psi 1034 kPa Geared wheel operator
VFF2UW2YGX 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs 150 psi 1034 kPa Geared wheel operator

**VFF50-0400 position status monitor for VFF butterfly valves with high pressure pneumatic actuators is available to be ordered separately or will be
assembled to the valve if ordered at the same time. It is compatible with any high pressure pneumatic actuators without pneumatic or electro-
pneumatic positioner (e.g. VFF...XR/XS, VFF...CR/CS, or VFF...ER/ES).
Industrial Combustion
Controls

70-6910 617
Butterfly Control Valves
VFF3 Three-way (A-B-AB) Butterfly Control Valves
Body Pattern: 3 way (A-B-AB porting)
Valve Action: Normally Closed
Connection Type: Lugged
Controlled Fluid: Chilled or hot water with up to 50% Glycol. Not for
use with steam or fuels.
Actuator Control Type: Electric floating
Flow Characteristic: Modified Equal Percent
Mounting: ANSI Flanged
Static Pressure Rating (max): 250 psi (1724 kPa)
Actuator Ambient Temperature Ratings: -5 F to 140 F (-20 C to 60 C)
Temperature Range: -40 F to 250 F (-40 C to 121 C)
Number of Flange Bolts
For 2 in., 2-1/2 in., 3 in. valves: 4
For 4 in., 5 in., 6 in., 8 in., valves: 8
For 10 in., 12 in., 14 in. valves: 12
For 16 in., 18 in. valves: 16
For 20 in. valves: 20
Flange Bolt Thread
For 2 in., 2-1/2 in., 3 in. valves: 5/8 in.-11 pitch
For 4 in., 5 in., 6 in., 8 in., valves: 3/4 in.-10 pitch
For 10 in., 12 in., 14 in. valves: 7/8 in.-9 pitch
For 16 in., 18 in., 20 in. valves: 1-1/8 in.-7 pitch
Materials
(Body): Polyester-coated cast iron ASTM A126 Class B
(Stem): 416 Stainless Steel
(Seat): Peroxide-cured EPDM resilient seat
(Plug/Ball/Disc): Nylon 11-coated ductile iron
Approvals:
CE: Compliant
Underwriters Laboratories, Inc. C/US UL873, Plenum Rated
Resilient seat three-way valves provide control for HVAC system
applications including chilled water, hot water, cooling tower Accessories:
water, and thermal storage systems. VFF50-0400 Position status monitor for VFF butterfly valves with high
pressure pneumatic actuators
Valves with Electric Actuator

Maximum
Differential
Pressure
Capacity at 60 Capacity at 90 Ratings
Valve Size degrees stroke degrees stroke (Close-off)
Actuator Type of
Product Number (inch) (DN) (Cv) (Kv) (Cv) (Kv) Selection Enclosure (psi) (kPa) Comments Includes
VFF3FW1Y2A 2 in. DN50 61 Cv 53 kvs 144 Cv 125 kvs Non-Spring Return NEMA 2 housing 175 psi 1206 kPa — —
Floating control
VFF3FW1Y2B 2 in. DN50 61 Cv 53 kvs 144 Cv 125 kvs Non-Spring Return NEMA 2 housing 175 psi 1206 kPa — —
Modulating control
VFF3FW1Y2C 2 in. DN50 61 Cv 53 kvs 144 Cv 125 kvs Spring Return 2- NEMA 2 housing 175 psi 1206 kPa — —
Position, 24 Vac
VFF3FW1Y2D 2 in. DN50 61 Cv 53 kvs 144 Cv 125 kvs Spring Return NEMA 2 housing 175 psi 1206 kPa — —
Floating/Modulating
control
VFF3FW1Y2E 2 in. DN50 61 Cv 53 kvs 144 Cv 125 kvs Spring Return 2- NEMA 2 housing 175 psi 1206 kPa — —
Position, 120 Vac
VFF3FW1YXA 2 in. DN50 61 Cv 53 kvs 144 Cv 125 kvs Non-Spring Return NEMA 4X (Water 175 psi 1206 kPa — Anti-condensation
120 Vac Floating tight, corrosion- heater, manual
control proof) housing gear wheel
VFF3FW1YXB 2 in. DN50 61 Cv 53 kvs 144 Cv 125 kvs Non-Spring Return NEMA 4X (Water 175 psi 1206 kPa — Anti-condensation
Modulating control tight, corrosion- heater, manual
proof) housing gear wheel
VFF3GW1Y2A 2-1/2 in. DN65 107 Cv 93 kvs 282 Cv 244 kvs Non-Spring Return NEMA 2 housing 175 psi 1206 kPa — —
Floating control
VFF3GW1Y2B 2-1/2 in. DN65 107 Cv 93 kvs 282 Cv 244 kvs Non-Spring Return NEMA 2 housing 175 psi 1206 kPa — —
Modulating control
VFF3GW1Y2C 2-1/2 in. DN65 107 Cv 93 kvs 282 Cv 244 kvs Spring Return 2- NEMA 2 housing 175 psi 1206 kPa — —
Position, 24 Vac
VFF3GW1Y2D 2-1/2 in. DN65 107 Cv 93 kvs 282 Cv 244 kvs Spring Return NEMA 2 housing 175 psi 1206 kPa — —
Floating/Modulating
control
VFF3GW1Y2E 2-1/2 in. DN65 107 Cv 93 kvs 282 Cv 244 kvs Spring Return 2- NEMA 2 housing 175 psi 1206 kPa — —
Position, 120 Vac

618 customer.honeywell.com 70-6910


Butterfly Control Valves

Controls
Maximum

Home
Differential
Pressure
Capacity at 60 Capacity at 90 Ratings
Valve Size degrees stroke degrees stroke (Close-off)
Actuator Type of
Product Number (inch) (DN) (Cv) (Kv) (Cv) (Kv) Selection Enclosure (psi) (kPa) Comments Includes
VFF3GW1YXA 2-1/2 in. DN65 107 Cv 93 kvs 282 Cv 244 kvs Non-Spring Return NEMA 4X (Water 175 psi 1206 kPa — Anti-condensation
120 Vac Floating tight, corrosion- heater, manual

Indoor Air Quality


control proof) housing gear wheel
VFF3GW1YXB 2-1/2 in. DN65 107 Cv 93 kvs 282 Cv 244 kvs Non-Spring Return NEMA 4X (Water 175 psi 1206 kPa — Anti-condensation
Modulating control tight, corrosion- heater, manual
proof) housing gear wheel
VFF3HW1Y2A 3 in. DN80 154 Cv 133 kvs 461 Cv 399 kvs Non-Spring Return NEMA 2 housing 175 psi 1206 kPa — —
Floating control
VFF3HW1Y2B 3 in. DN80 154 Cv 133 kvs 461 Cv 399 kvs Non-Spring Return NEMA 2 housing 175 psi 1206 kPa — —
Modulating control

Combustion Controls
VFF3HW1Y2C 3 in. DN80 154 Cv 133 kvs 461 Cv 399 kvs Spring Return 2- NEMA 2 housing 175 psi 1206 kPa — —
Position, 24 Vac

Residential
VFF3HW1Y2D 3 in. DN80 154 Cv 133 kvs 461 Cv 399 kvs Spring Return NEMA 2 housing 175 psi 1206 kPa — —
Floating/Modulating
control
VFF3HW1Y2E 3 in. DN80 154 Cv 133 kvs 461 Cv 399 kvs Spring Return 2- NEMA 2 housing 175 psi 1206 kPa — —
Position, 120 Vac
VFF3HW1YXA 3 in. DN80 154 Cv 133 kvs 461 Cv 399 kvs Non-Spring Return NEMA 4X (Water 175 psi 1206 kPa — Anti-condensation
120 Vac Floating tight, corrosion- heater, manual
control proof) housing gear wheel

Hydronic Controls
VFF3HW1YXB 3 in. DN80 154 Cv 133 kvs 461 Cv 399 kvs Non-Spring Return NEMA 4X (Water 175 psi 1206 kPa — Anti-condensation
Modulating control tight, corrosion- heater, manual
proof) housing gear wheel
VFF3JV1Y2A 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs Non-Spring Return NEMA 2 housing 50 psi 345 kPa — —
Floating control
VFF3JV1Y2B 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs Non-Spring Return NEMA 2 housing 50 psi 345 kPa — —
Modulating control
VFF3JV1Y2C 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs Spring Return 2- NEMA 2 housing 50 psi 345 kPa — —
Position, 24 Vac
VFF3JV1Y2D 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs Spring Return NEMA 2 housing 50 psi 345 kPa — —

Controls
Floating/Modulating

Water
control
VFF3JV1Y2E 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs Spring Return 2- NEMA 2 housing 50 psi 345 kPa — —
Position, 120 Vac
VFF3JW1Y2A 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs Non-Spring Return NEMA 2 housing 175 psi 1206 kPa — —
Floating control
VFF3JW1Y2B 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs Non-Spring Return NEMA 2 housing 175 psi 1206 kPa — —

Building Automation
Modulating control
VFF3JV1YXA 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs Non-Spring Return NEMA 4X (Water 50 psi 345 kPa — Anti-condensation
120 Vac Floating tight, corrosion- heater, manual
control proof) housing gear wheel
VFF3JV1YXB 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs Non-Spring Return NEMA 4X (Water 50 psi 345 kPa — Anti-condensation
Modulating control tight, corrosion- heater, manual
proof) housing gear wheel
VFF3JW1YXA 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs Non-Spring Return NEMA 4X (Water 175 psi 1206 kPa — Anti-condensation
120 Vac Floating tight, corrosion- heater, manual
control proof) housing gear wheel

Components
VFF3JW1YXB 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs Non-Spring Return NEMA 4X (Water 175 psi 1206 kPa — Anti-condensation

Commercial
Modulating control tight, corrosion- heater, manual
proof) housing gear wheel
VFF3KV1Y2A 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs Non-Spring Return NEMA 2 housing 50 psi 345 kPa — —
Floating control
VFF3KV1Y2B 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs Non-Spring Return NEMA 2 housing 50 psi 345 kPa — —
Modulating control
VFF3KV1Y2C 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs Spring Return 2- NEMA 2 housing 50 psi 345 kPa Chilled water —
Pneumatic Controls

Position, 24 Vac service only


VFF3KV1Y2D 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs Spring Return NEMA 2 housing 50 psi 345 kPa Chilled water —
Floating/Modulating service only
control
VFF3KV1Y2E 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs Spring Return 2- NEMA 2 housing 50 psi 345 kPa Chilled water —
Position, 120 Vac service only
VFF3KW1Y2A 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs Non-Spring Return NEMA 2 housing 175 psi 1206 kPa — —
Floating control
VFF3KW1Y2B 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs Non-Spring Return NEMA 2 housing 175 psi 1206 kPa — —
Industrial Combustion

Modulating control
VFF3KV1YXA 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs Non-Spring Return NEMA 4X (Water 50 psi 345 kPa — Anti-condensation
Controls

120 Vac Floating tight, corrosion- heater, manual


control proof) housing gear wheel

70-6910 619
Butterfly Control Valves
Maximum
Differential
Pressure
Capacity at 60 Capacity at 90 Ratings
Valve Size degrees stroke degrees stroke (Close-off)
Actuator Type of
Product Number (inch) (DN) (Cv) (Kv) (Cv) (Kv) Selection Enclosure (psi) (kPa) Comments Includes
VFF3KV1YXB 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs Non-Spring Return NEMA 4X (Water 50 psi 345 kPa — Anti-condensation
Modulating control tight, corrosion- heater, manual
proof) housing gear wheel
VFF3KW1YXA 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs Non-Spring Return NEMA 4X (Water 175 psi 1206 kPa — Anti-condensation
120 Vac Floating tight, corrosion- heater, manual
control proof) housing gear wheel
VFF3KW1YXB 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs Non-Spring Return NEMA 4X (Water 175 psi 1206 kPa — Anti-condensation
Modulating control tight, corrosion- heater, manual
proof) housing gear wheel
VFF3LV1Y2A 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs Non-Spring Return NEMA 2 housing 50 psi 345 kPa — —
Floating control
VFF3LV1Y2B 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs Non-Spring Return NEMA 2 housing 50 psi 345 kPa — —
Modulating control
VFF3LV1YXA 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs Non-Spring Return NEMA 4X (Water 50 psi 345 kPa — Anti-condensation
120 Vac Floating tight, corrosion- heater, manual
control proof) housing gear wheel
VFF3LV1YXB 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs Non-Spring Return NEMA 4X (Water 50 psi 345 kPa — Anti-condensation
Modulating control tight, corrosion- heater, manual
proof) housing gear wheel
VFF3LW1YXA 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs Non-Spring Return NEMA 4X (Water 175 psi 1206 kPa — Anti-condensation
120 Vac Floating tight, corrosion- heater, manual
control proof) housing gear wheel
VFF3LW1YXB 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs Non-Spring Return NEMA 4X (Water 175 psi 1206 kPa — Anti-condensation
Modulating control tight, corrosion- heater, manual
proof) housing gear wheel
VFF3MV1YXA 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs Non-Spring Return NEMA 4X (Water 50 psi 345 kPa — Anti-condensation
120 Vac Floating tight, corrosion- heater, manual
control proof) housing gear wheel
VFF3MV1YXB 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs Non-Spring Return NEMA 4X (Water 50 psi 345 kPa — Anti-condensation
Modulating control tight, corrosion- heater, manual
proof) housing gear wheel
VFF3MW1YXA 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs Non-Spring Return NEMA 4X (Water 175 psi 1206 kPa — Anti-condensation
120 Vac Floating tight, corrosion- heater, manual
control proof) housing gear wheel
VFF3MW1YXB 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs Non-Spring Return NEMA 4X (Water 175 psi 1206 kPa — Anti-condensation
Modulating control tight, corrosion- heater, manual
proof) housing gear wheel
VFF3NV1YXA 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs Non-Spring Return NEMA 4X (Water 50 psi 345 kPa — Anti-condensation
120 Vac Floating tight, corrosion- heater, manual
control proof) housing gear wheel
VFF3NV1YXB 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs Non-Spring Return NEMA 4X (Water 50 psi 345 kPa — Anti-condensation
Modulating control tight, corrosion- heater, manual
proof) housing gear wheel
VFF3NW1YXA 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs Non-Spring Return NEMA 4X (Water 175 psi 1206 kPa — Anti-condensation
120 Vac Floating tight, corrosion- heater, manual
control proof) housing gear wheel
VFF3NW1YXB 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs Non-Spring Return NEMA 4X (Water 175 psi 1206 kPa — Anti-condensation
Modulating control tight, corrosion- heater, manual
proof) housing gear wheel
VFF3PV1YXA 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs Non-Spring Return NEMA 4X (Water 50 psi 345 kPa — Anti-condensation
120 Vac Floating tight, corrosion- heater, manual
control proof) housing gear wheel
VFF3PV1YXB 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs Non-Spring Return NEMA 4X (Water 50 psi 345 kPa — Anti-condensation
Modulating control tight, corrosion- heater, manual
proof) housing gear wheel
VFF3PW1YXA 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs Non-Spring Return NEMA 4X (Water 175 psi 1206 kPa — Anti-condensation
120 Vac Floating tight, corrosion- heater, manual
control proof) housing gear wheel
VFF3PW1YXB 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs Non-Spring Return NEMA 4X (Water 175 psi 1206 kPa — Anti-condensation
Modulating control tight, corrosion- heater, manual
proof) housing gear wheel
VFF3RW1Y4A 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs Non-Spring Return NEMA 4 (Water 150 psi 1034 kPa — Anti-condensation
120 Vac Floating tight) housing heater, manual
control gear wheel
VFF3RW1Y4B 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs Non-Spring Return NEMA 4 (Water 150 psi 1034 kPa — Anti-condensation
20 mA Modulating tight) housing heater, manual
control gear wheel
VFF3RV1YXA 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs Non-Spring Return NEMA 4X (Water 50 psi 345 kPa — Anti-condensation
120 Vac Floating tight, corrosion- heater, manual
control proof) housing gear wheel

620 customer.honeywell.com 70-6910


Butterfly Control Valves

Controls
Maximum

Home
Differential
Pressure
Capacity at 60 Capacity at 90 Ratings
Valve Size degrees stroke degrees stroke (Close-off)
Actuator Type of
Product Number (inch) (DN) (Cv) (Kv) (Cv) (Kv) Selection Enclosure (psi) (kPa) Comments Includes
VFF3RV1YXB 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs Non-Spring Return NEMA 4X (Water 50 psi 345 kPa — Anti-condensation
Modulating control tight, corrosion- heater, manual

Indoor Air Quality


proof) housing gear wheel
VFF3SW1Y4A 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs Non-Spring Return NEMA 4 (Water 150 psi 1034 kPa — Anti-condensation
120 Vac Floating tight) housing heater, manual
control gear wheel
VFF3SW1Y4B 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs Non-Spring Return NEMA 4 (Water 150 psi 1034 kPa — Anti-condensation
20 mA Modulating tight) housing heater, manual
control gear wheel
VFF3SV1YXA 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs Non-Spring Return NEMA 4X (Water 50 psi 345 kPa — Anti-condensation

Combustion Controls
120 Vac Floating tight, corrosion- heater, manual
control proof) housing gear wheel

Residential
VFF3SV1YXB 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs Non-Spring Return NEMA 4X (Water 50 psi 345 kPa — Anti-condensation
Modulating control tight, corrosion- heater, manual
proof) housing gear wheel
VFF3TV1Y4A 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs Non-Spring Return NEMA 4 (Water 50 psi 345 kPa — Anti-condensation
120 Vac Floating tight) housing heater, manual
control gear wheel
VFF3TV1Y4B 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs Non-Spring Return NEMA 4 (Water 50 psi 345 kPa — Anti-condensation
20 mA Modulating tight) housing heater, manual

Hydronic Controls
control gear wheel
VFF3TW1Y4A 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs Non-Spring Return NEMA 4 (Water 150 psi 1034 kPa — Anti-condensation
120 Vac Floating tight) housing heater, manual
control gear wheel
VFF3TW1Y4B 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs Non-Spring Return NEMA 4 (Water 150 psi 1034 kPa — Anti-condensation
20 mA Modulating tight) housing heater, manual
control gear wheel
VFF3UV1Y4A 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs Non-Spring Return NEMA 4 (Water 50 psi 345 kPa — Anti-condensation
120 Vac Floating tight) housing heater, manual
control gear wheel
VFF3UV1Y4B 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs Non-Spring Return NEMA 4 (Water 50 psi 345 kPa — Anti-condensation

Controls
20 mA Modulating tight) housing heater, manual

Water
control gear wheel
VFF3UW1Y4A 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs Non-Spring Return NEMA 4 (Water 150 psi 1034 kPa — Anti-condensation
120 Vac Floating tight) housing heater, manual
control gear wheel
VFF3UW1Y4B 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs Non-Spring Return NEMA 4 (Water 150 psi 1034 kPa — Anti-condensation
20 mA Modulating tight) housing heater, manual

Building Automation
control gear wheel
Valves with Pneumatic Actuator

Maximum
Differential
Pressure
Capacity at 60 Capacity at 90 Ratings (Close-
Valve Size degrees stroke degrees stroke off)
Type of
Product Number (inch) (DN) (Cv) (Kv) (Cv) (Kv) Actuator Selection Enclosure (psi) (kPa) Comments Includes
VFF3FW1Y8P 2 in. DN50 61 Cv 53 kvs Stroke limited to 70 20 psi spring return Pneumatic 175 psi 1206 kPa Linear actuator —

Components
Commercial
degrees
VFF3FW1YCR 2 in. DN50 61 Cv 53 kvs 144 Cv 125 kvs 2-position, 24 Vac solenoid Pneumatic 175 psi 1206 kPa — Position
80 psi bidirectional indicator
VFF3FW1YCS 2 in. DN50 61 Cv 53 kvs 144 Cv 125 kvs 2-position, 24 Vac solenoid Pneumatic 175 psi 1206 kPa — Position
80 psi spring return indicator
VFF3FW1YDR 2 in. DN50 61 Cv 53 kvs 144 Cv 125 kvs 4-20 mA Servo 80 psi Pneumatic 175 psi 1206 kPa — Position
bidirectional indicator
Pneumatic Controls

VFF3FW1YDS 2 in. DN50 61 Cv 53 kvs 144 Cv 125 kvs 4-20 mA Servo, 80 psi Pneumatic 175 psi 1206 kPa — Position
spring return indicator
VFF3FW1YER 2 in. DN50 61 Cv 53 kvs 144 Cv 125 kvs 2-position, 120 Vac solenoid Pneumatic 175 psi 1206 kPa — Position
80 psi bidirectional indicator
VFF3FW1YPP 2 in. DN50 61 Cv 53 kvs Stroke limited to 70 Modulating w/positioner, Pneumatic 175 psi 1206 kPa Linear actuator —
degrees spring return
VFF3FW1YPR 2 in. DN50 61 Cv 53 kvs 144 Cv 125 kvs Modulating w/positioner, Pneumatic 175 psi 1206 kPa — Position
bidirectional indicator
VFF3FW1YPS 2 in. DN50 61 Cv 53 kvs 144 Cv 125 kvs Modulating w/positioner, Pneumatic 175 psi 1206 kPa — Position
Industrial Combustion

spring return indicator


VFF3FW1YXR 2 in. DN50 61 Cv 53 kvs 144 Cv 125 kvs 2-position 80 psi Pneumatic 175 psi 1206 kPa — Position
Controls

bidirectional indicator

70-6910 621
Butterfly Control Valves
Maximum
Differential
Pressure
Capacity at 60 Capacity at 90 Ratings (Close-
Valve Size degrees stroke degrees stroke off)
Type of
Product Number (inch) (DN) (Cv) (Kv) (Cv) (Kv) Actuator Selection Enclosure (psi) (kPa) Comments Includes
VFF3FW1YXS 2 in. DN50 61 Cv 53 kvs 144 Cv 125 kvs 2-position, 80 psi spring Pneumatic 175 psi 1206 kPa — Position
return indicator
VFF3GW1Y8P 2-1/2 in. DN65 107 Cv 93 kvs Stroke limited to 70 20 psi spring return Pneumatic 175 psi 1206 kPa Linear actuator —
degrees
VFF3GW1YCR 2-1/2 in. DN65 107 Cv 93 kvs 282 Cv 244 kvs 2-position, 24 Vac solenoid Pneumatic 175 psi 1206 kPa — Position
80 psi bidirectional indicator
VFF3GW1YCS 2-1/2 in. DN65 107 Cv 93 kvs 282 Cv 244 kvs 2-position, 24 Vac solenoid Pneumatic 175 psi 1206 kPa — Position
80 psi spring return indicator
VFF3GW1YDR 2-1/2 in. DN65 107 Cv 93 kvs 282 Cv 244 kvs 4-20 mA Servo 80 psi Pneumatic 175 psi 1206 kPa — Position
bidirectional indicator
VFF3GW1YDS 2-1/2 in. DN65 107 Cv 93 kvs 282 Cv 244 kvs 4-20 mA Servo, 80 psi Pneumatic 175 psi 1206 kPa — Position
spring return indicator
VFF3GW1YER 2-1/2 in. DN65 107 Cv 93 kvs 282 Cv 244 kvs 2-position, 120 Vac solenoid Pneumatic 175 psi 1206 kPa — Position
80 psi bidirectional indicator
VFF3GW1YES 2-1/2 in. DN65 107 Cv 93 kvs 282 Cv 244 kvs 2-position, 120 Vac solenoid Pneumatic 175 psi 1206 kPa — Position
80 psi spring return indicator
VFF3GW1YPP 2-1/2 in. DN65 107 Cv 93 kvs Stroke limited to 70 Modulating w/positioner, Pneumatic 175 psi 1206 kPa Linear actuator —
degrees spring return
VFF3GW1YPR 2-1/2 in. DN65 107 Cv 93 kvs 282 Cv 244 kvs Modulating w/positioner, Pneumatic 175 psi 1206 kPa — Position
bidirectional indicator
VFF3GW1YPS 2-1/2 in. DN65 107 Cv 93 kvs 282 Cv 244 kvs Modulating w/positioner, Pneumatic 175 psi 1206 kPa — Position
spring return indicator
VFF3GW1YXR 2-1/2 in. DN65 107 Cv 93 kvs 282 Cv 244 kvs 2-position 80 psi Pneumatic 175 psi 1206 kPa — Position
bidirectional indicator
VFF3GW1YXS 2-1/2 in. DN65 107 Cv 93 kvs 282 Cv 244 kvs 2-position, 80 psi spring Pneumatic 175 psi 1206 kPa — Position
return indicator
VFF3HW1Y8P 3 in. DN80 154 Cv 133 kvs Stroke limited to 70 20 psi spring return Pneumatic 175 psi 1206 kPa Linear actuator —
degrees
VFF3HW1YCR 3 in. DN80 154 Cv 133 kvs 461 Cv 399 kvs 2-position, 24 Vac solenoid Pneumatic 175 psi 1206 kPa — Position
80 psi bidirectional indicator
VFF3HW1YCS 3 in. DN80 154 Cv 133 kvs 461 Cv 399 kvs 2-position, 24 Vac solenoid Pneumatic 175 psi 1206 kPa — Position
80 psi spring return indicator
VFF3HW1YDR 3 in. DN80 154 Cv 133 kvs 461 Cv 399 kvs 4-20 mA Servo 80 psi Pneumatic 175 psi 1206 kPa — Position
bidirectional indicator
VFF3HW1YDS 3 in. DN80 154 Cv 133 kvs 461 Cv 399 kvs 4-20 mA Servo, 80 psi Pneumatic 175 psi 1206 kPa — Position
spring return indicator
VFF3HW1YER 3 in. DN80 154 Cv 133 kvs 461 Cv 399 kvs 2-position, 120 Vac solenoid Pneumatic 175 psi 1206 kPa — Position
80 psi bidirectional indicator
VFF3HW1YES 3 in. DN80 154 Cv 133 kvs 461 Cv 399 kvs 2-position, 120 Vac solenoid Pneumatic 175 psi 1206 kPa — Position
80 psi spring return indicator
VFF3HW1YPP 3 in. DN80 154 Cv 133 kvs Stroke limited to 70 Modulating w/positioner, Pneumatic 175 psi 1206 kPa Linear actuator —
degrees spring return
VFF3HW1YPR 3 in. DN80 154 Cv 133 kvs 461 Cv 399 kvs Modulating w/positioner, Pneumatic 175 psi 1206 kPa — Position
bidirectional indicator
VFF3HW1YPS 3 in. DN80 154 Cv 133 kvs 461 Cv 399 kvs Modulating w/positioner, Pneumatic 175 psi 1206 kPa — Position
spring return indicator
VFF3HW1YXR 3 in. DN80 154 Cv 133 kvs 461 Cv 399 kvs 2-position 80 psi Pneumatic 175 psi 1206 kPa — Position
bidirectional indicator
VFF3HW1YXS 3 in. DN80 154 Cv 133 kvs 461 Cv 399 kvs 2-position, 80 psi spring Pneumatic 175 psi 1206 kPa — Position
return indicator
VFF3JV1Y8P 4 in. DN100 274 Cv 237 kvs Stroke limited to 70 20 psi spring return Pneumatic 50 psi 345 kPa Linear actuator —
degrees
VFF3JV1YCR 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs 2-position, 24 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi bidirectional indicator
VFF3JV1YCS 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs 2-position, 24 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi spring return indicator
VFF3JV1YDR 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs 4-20 mA Servo 80 psi Pneumatic 50 psi 345 kPa — Position
bidirectional indicator
VFF3JV1YDS 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs 4-20 mA Servo, 80 psi Pneumatic 50 psi 345 kPa — Position
spring return indicator
VFF3JV1YER 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs 2-position, 120 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi bidirectional indicator
VFF3JV1YES 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs 2-position, 120 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi spring return indicator
VFF3JV1YPP 4 in. DN100 274 Cv 237 kvs Stroke limited to 70 Modulating w/positioner, Pneumatic 50 psi 345 kPa Linear actuator —
degrees spring return

622 customer.honeywell.com 70-6910


Butterfly Control Valves

Controls
Maximum

Home
Differential
Pressure
Capacity at 60 Capacity at 90 Ratings (Close-
Valve Size degrees stroke degrees stroke off)
Type of
Product Number (inch) (DN) (Cv) (Kv) (Cv) (Kv) Actuator Selection Enclosure (psi) (kPa) Comments Includes
VFF3JV1YPR 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs Modulating w/positioner, Pneumatic 50 psi 345 kPa — Position
bidirectional indicator

Indoor Air Quality


VFF3JV1YPS 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs Modulating w/positioner, Pneumatic 50 psi 345 kPa — Position
spring return indicator
VFF3JV1YXR 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs 2-position 80 psi Pneumatic 50 psi 345 kPa — Position
bidirectional indicator
VFF3JV1YXS 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs 2-position, 80 psi spring Pneumatic 50 psi 345 kPa — Position
return indicator
VFF3JW1Y8P 4 in. DN100 274 Cv 237 kvs Stroke limited to 70 20 psi spring return Pneumatic 175 psi 1206 kPa Linear actuator —
degrees

Combustion Controls
VFF3JW1YCR 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs 2-position, 24 Vac solenoid Pneumatic 175 psi 1206 kPa — Position
80 psi bidirectional indicator

Residential
VFF3JW1YCS 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs 2-position, 24 Vac solenoid Pneumatic 175 psi 1206 kPa — Position
80 psi spring return indicator
VFF3JW1YDR 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs 4-20 mA Servo 80 psi Pneumatic 175 psi 1206 kPa — Position
bidirectional indicator
VFF3JW1YDS 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs 4-20 mA Servo, 80 psi Pneumatic 175 psi 1206 kPa — Position
spring return indicator
VFF3JW1YER 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs 2-position, 120 Vac solenoid Pneumatic 175 psi 1206 kPa — Position

Hydronic Controls
80 psi bidirectional indicator
VFF3JW1YES 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs 2-position, 120 Vac solenoid Pneumatic 175 psi 1206 kPa — Position
80 psi spring return indicator
VFF3JW1YPP 4 in. DN100 274 Cv 237 kvs Stroke limited to 70 Modulating w/positioner, Pneumatic 175 psi 1206 kPa Linear actuator —
degrees spring return
VFF3JW1YPR 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs Modulating w/positioner, Pneumatic 175 psi 1206 kPa — Position
bidirectional indicator
VFF3JW1YPS 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs Modulating w/positioner, Pneumatic 175 psi 1206 kPa — Position
spring return indicator
VFF3JW1YXR 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs 2-position 80 psi Pneumatic 175 psi 1206 kPa — Position

Controls
bidirectional indicator

Water
VFF3JW1YXS 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs 2-position, 80 psi spring Pneumatic 175 psi 1206 kPa — Position
return indicator
VFF3KV1YCR 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs 2-position, 24 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi bidirectional indicator
VFF3KV1YCS 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs 2-position, 24 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi spring return indicator

Building Automation
VFF3KV1YDR 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs 4-20 mA Servo 80 psi Pneumatic 50 psi 345 kPa — Position
bidirectional indicator
VFF3KV1YDS 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs 4-20 mA Servo, 80 psi Pneumatic 50 psi 345 kPa — Position
spring return indicator
VFF3KV1YER 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs 2-position, 120 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi bidirectional indicator
VFF3KV1YES 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs 2-position, 120 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi spring return indicator
VFF3KV1YPR 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs Modulating w/positioner, Pneumatic 50 psi 345 kPa — Position
bidirectional indicator

Components
Commercial
VFF3KV1YPS 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs Modulating w/positioner, Pneumatic 50 psi 345 kPa — Position
spring return indicator
VFF3KV1YXR 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs 2-position 80 psi Pneumatic 50 psi 345 kPa — Position
bidirectional indicator
VFF3KV1YXS 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs 2-position, 80 psi spring Pneumatic 50 psi 345 kPa — Position
return indicator
VFF3KW1Y8P 5 in. DN125 428 Cv 370 kvs Stroke limited to 70 20 psi spring return Pneumatic 175 psi 1206 kPa Linear actuator —
degrees
Pneumatic Controls

VFF3KW1YCR 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs 2-position, 24 Vac solenoid Pneumatic 175 psi 1206 kPa — Position
80 psi bidirectional indicator
VFF3KW1YCS 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs 2-position, 24 Vac solenoid Pneumatic 175 psi 1206 kPa — Position
80 psi spring return indicator
VFF3KW1YDR 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs 4-20 mA Servo 80 psi Pneumatic 175 psi 1206 kPa — Position
bidirectional indicator
VFF3KW1YDS 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs 4-20 mA Servo, 80 psi Pneumatic 175 psi 1206 kPa — Position
spring return indicator
Industrial Combustion

VFF3KW1YER 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs 2-position, 120 Vac solenoid Pneumatic 175 psi 1206 kPa — Position
80 psi bidirectional indicator
Controls

VFF3KW1YES 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs 2-position, 120 Vac solenoid Pneumatic 175 psi 1206 kPa — Position
80 psi spring return indicator

70-6910 623
Butterfly Control Valves
Maximum
Differential
Pressure
Capacity at 60 Capacity at 90 Ratings (Close-
Valve Size degrees stroke degrees stroke off)
Type of
Product Number (inch) (DN) (Cv) (Kv) (Cv) (Kv) Actuator Selection Enclosure (psi) (kPa) Comments Includes
VFF3KW1YPP 5 in. DN125 428 Cv 370 kvs Stroke limited to 70 Modulating w/positioner, Pneumatic 175 psi 1206 kPa Linear actuator —
degrees spring return
VFF3KW1YPR 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs Modulating w/positioner, Pneumatic 175 psi 1206 kPa — Position
bidirectional indicator
VFF3KW1YPS 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs Modulating w/positioner, Pneumatic 175 psi 1206 kPa — Position
spring return indicator
VFF3KW1YXR 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs 2-position 80 psi Pneumatic 175 psi 1206 kPa — Position
bidirectional indicator
VFF3KW1YXS 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs 2-position, 80 psi spring Pneumatic 175 psi 1206 kPa — Position
return indicator
VFF3LV1Y8P 6 in. DN150 567 Cv 490 kvs Stroke limited to 70 20 psi spring return Pneumatic 50 psi 345 kPa Linear actuator —
degrees
VFF3LV1YCR 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs 2-position, 24 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi bidirectional indicator
VFF3LV1YCS 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs 2-position, 24 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi spring return indicator
VFF3LV1YDR 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs 4-20 mA Servo 80 psi Pneumatic 50 psi 345 kPa — Position
bidirectional indicator
VFF3LV1YDS 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs 4-20 mA Servo, 80 psi Pneumatic 50 psi 345 kPa — Position
spring return indicator
VFF3LV1YER 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs 2-position, 120 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi bidirectional indicator
VFF3LV1YES 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs 2-position, 120 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi spring return indicator
VFF3LV1YPP 6 in. DN150 567 Cv 490 kvs Stroke limited to 70 Modulating w/positioner, Pneumatic 50 psi 345 kPa Linear actuator —
degrees spring return
VFF3LV1YPR 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs Modulating w/positioner, Pneumatic 50 psi 345 kPa — Position
bidirectional indicator
VFF3LV1YPS 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs Modulating w/positioner, Pneumatic 50 psi 345 kPa — Position
spring return indicator
VFF3LV1YXR 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs 2-position 80 psi Pneumatic 50 psi 345 kPa — Position
bidirectional indicator
VFF3LV1YXS 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs 2-position, 80 psi spring Pneumatic 50 psi 345 kPa — Position
return indicator
VFF3LW1Y8P 6 in. DN150 567 Cv 490 kvs Stroke limited to 70 20 psi spring return Pneumatic 175 psi 1206 kPa Linear actuator —
degrees
VFF3LW1YCR 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs 2-position, 24 Vac solenoid Pneumatic 175 psi 1206 kPa — Position
80 psi bidirectional indicator
VFF3LW1YCS 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs 2-position, 24 Vac solenoid Pneumatic 175 psi 1206 kPa — Position
80 psi spring return indicator
VFF3LW1YDR 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs 4-20 mA Servo 80 psi Pneumatic 175 psi 1206 kPa — Position
bidirectional indicator
VFF3LW1YDS 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs 4-20 mA Servo, 80 psi Pneumatic 175 psi 1206 kPa — Position
spring return indicator
VFF3LW1YER 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs 2-position, 120 Vac solenoid Pneumatic 175 psi 1206 kPa — Position
80 psi bidirectional indicator
VFF3LW1YES 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs 2-position, 120 Vac solenoid Pneumatic 175 psi 1206 kPa — Position
80 psi spring return indicator
VFF3LW1YPP 6 in. DN150 567 Cv 490 kvs Stroke limited to 70 Modulating w/positioner, Pneumatic 175 psi 1206 kPa Linear actuator —
degrees spring return
VFF3LW1YPR 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs Modulating w/positioner, Pneumatic 175 psi 1206 kPa — Position
bidirectional indicator
VFF3LW1YPS 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs Modulating w/positioner, Pneumatic 175 psi 1206 kPa — Position
spring return indicator
VFF3LW1YXR 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs 2-position 80 psi Pneumatic 175 psi 1206 kPa — Position
bidirectional indicator
VFF3LW1YXS 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs 2-position, 80 psi spring Pneumatic 175 psi 1206 kPa — Position
return indicator
VFF3MV1Y8P 8 in. DN200 1081 Cv 935 kvs Stroke limited to 70 20 psi spring return Pneumatic 50 psi 345 kPa Linear actuator —
degrees
VFF3MV1YCR 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs 2-position, 24 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi bidirectional indicator
VFF3MV1YCS 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs 2-position, 24 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi spring return indicator
VFF3MV1YDR 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs 4-20 mA Servo 80 psi Pneumatic 50 psi 345 kPa — Position
bidirectional indicator

624 customer.honeywell.com 70-6910


Butterfly Control Valves

Controls
Maximum

Home
Differential
Pressure
Capacity at 60 Capacity at 90 Ratings (Close-
Valve Size degrees stroke degrees stroke off)
Type of
Product Number (inch) (DN) (Cv) (Kv) (Cv) (Kv) Actuator Selection Enclosure (psi) (kPa) Comments Includes
VFF3MV1YDS 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs 4-20 mA Servo, 80 psi Pneumatic 50 psi 345 kPa — Position
spring return indicator

Indoor Air Quality


VFF3MV1YER 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs 2-position, 120 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi bidirectional indicator
VFF3MV1YES 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs 2-position, 120 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi spring return indicator
VFF3MV1YPP 8 in. DN200 1081 Cv 935 kvs Stroke limited to 70 Modulating w/positioner, Pneumatic 50 psi 345 kPa Linear actuator —
degrees spring return
VFF3MV1YPR 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs Modulating w/positioner, Pneumatic 50 psi 345 kPa — Position
bidirectional indicator

Combustion Controls
VFF3MV1YPS 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs Modulating w/positioner, Pneumatic 50 psi 345 kPa — Position
spring return indicator

Residential
VFF3MV1YXR 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs 2-position 80 psi Pneumatic 50 psi 345 kPa — Position
bidirectional indicator
VFF3MV1YXS 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs 2-position, 80 psi spring Pneumatic 50 psi 345 kPa — Position
return indicator
VFF3MW1YCR 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs 2-position, 24 Vac solenoid Pneumatic 175 psi 1206 kPa — Position
80 psi bidirectional indicator
VFF3MW1YCS 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs 2-position, 24 Vac solenoid Pneumatic 175 psi 1206 kPa — Position

Hydronic Controls
80 psi spring return indicator
VFF3MW1YDR 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs 4-20 mA Servo 80 psi Pneumatic 175 psi 1206 kPa — Position
bidirectional indicator
VFF3MW1YDS 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs 4-20 mA Servo, 80 psi Pneumatic 175 psi 1206 kPa — Position
spring return indicator
VFF3MW1YER 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs 2-position, 120 Vac solenoid Pneumatic 175 psi 1206 kPa — Position
80 psi bidirectional indicator
VFF3MW1YES 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs 2-position, 120 Vac solenoid Pneumatic 175 psi 1206 kPa — Position
80 psi spring return indicator
VFF3MW1YPR 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs Modulating w/positioner, Pneumatic 175 psi 1206 kPa — Position

Controls
bidirectional indicator

Water
VFF3MW1YPS 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs Modulating w/positioner, Pneumatic 175 psi 1206 kPa — Position
spring return indicator
VFF3MW1YXR 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs 2-position 80 psi Pneumatic 175 psi 1206 kPa — Position
bidirectional indicator
VFF3MW1YXS 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs 2-position, 80 psi spring Pneumatic 175 psi 1206 kPa — Position
return indicator

Building Automation
VFF3NV1YCR 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs 2-position, 24 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi bidirectional indicator
VFF3NV1YCS 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs 2-position, 24 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi spring return indicator
VFF3NV1YDR 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs 4-20 mA Servo 80 psi Pneumatic 50 psi 345 kPa — Position
bidirectional indicator
VFF3NV1YDS 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs 4-20 mA Servo, 80 psi Pneumatic 50 psi 345 kPa — Position
spring return indicator
VFF3NV1YER 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs 2-position, 120 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi bidirectional indicator

Components
Commercial
VFF3NV1YES 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs 2-position, 120 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi spring return indicator
VFF3NV1YPR 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs Modulating w/positioner, Pneumatic 50 psi 345 kPa — Position
bidirectional indicator
VFF3NV1YPS 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs Modulating w/positioner, Pneumatic 50 psi 345 kPa — Position
spring return indicator
VFF3NV1YXR 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs 2-position 80 psi Pneumatic 50 psi 345 kPa — Position
bidirectional indicator
Pneumatic Controls

VFF3NV1YXS 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs 2-position, 80 psi spring Pneumatic 50 psi 345 kPa — Position
return indicator
VFF3NW1YCR 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs 2-position, 24 Vac solenoid Pneumatic 175 psi 1206 kPa — Position
80 psi bidirectional indicator
VFF3NW1YCS 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs 2-position, 24 Vac solenoid Pneumatic 175 psi 1206 kPa — Position
80 psi spring return indicator
VFF3NW1YDR 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs 4-20 mA Servo 80 psi Pneumatic 175 psi 1206 kPa — Position
bidirectional indicator
Industrial Combustion

VFF3NW1YDS 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs 4-20 mA Servo, 80 psi Pneumatic 175 psi 1206 kPa — Position
spring return indicator
Controls

VFF3NW1YER 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs 2-position, 120 Vac solenoid Pneumatic 175 psi 1206 kPa — Position
80 psi bidirectional indicator

70-6910 625
Butterfly Control Valves
Maximum
Differential
Pressure
Capacity at 60 Capacity at 90 Ratings (Close-
Valve Size degrees stroke degrees stroke off)
Type of
Product Number (inch) (DN) (Cv) (Kv) (Cv) (Kv) Actuator Selection Enclosure (psi) (kPa) Comments Includes
VFF3NW1YES 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs 2-position, 120 Vac solenoid Pneumatic 175 psi 1206 kPa — Position
80 psi spring return indicator
VFF3NW1YPR 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs Modulating w/positioner, Pneumatic 175 psi 1206 kPa — Position
bidirectional indicator
VFF3NW1YPS 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs Modulating w/positioner, Pneumatic 175 psi 1206 kPa — Position
spring return indicator
VFF3NW1YXR 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs 2-position 80 psi Pneumatic 175 psi 1206 kPa — Position
bidirectional indicator
VFF3NW1YXS 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs 2-position, 80 psi spring Pneumatic 175 psi 1206 kPa — Position
return indicator
VFF3PV1YCR 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs 2-position, 24 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi bidirectional indicator
VFF3PV1YCS 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs 2-position, 24 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi spring return indicator
VFF3PV1YDR 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs 4-20 mA Servo 80 psi Pneumatic 50 psi 345 kPa — Position
bidirectional indicator
VFF3PV1YDS 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs 4-20 mA Servo, 80 psi Pneumatic 50 psi 345 kPa — Position
spring return indicator
VFF3PV1YER 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs 2-position, 120 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi bidirectional indicator
VFF3PV1YES 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs 2-position, 120 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi spring return indicator
VFF3PV1YPR 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs Modulating w/positioner, Pneumatic 50 psi 345 kPa — Position
bidirectional indicator
VFF3PV1YPS 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs Modulating w/positioner, Pneumatic 50 psi 345 kPa — Position
spring return indicator
VFF3PV1YXR 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs 2-position 80 psi Pneumatic 50 psi 345 kPa — Position
bidirectional indicator
VFF3PV1YXS 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs 2-position, 80 psi spring Pneumatic 50 psi 345 kPa — Position
return indicator
VFF3PW1YCR 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs 2-position, 24 Vac solenoid Pneumatic 175 psi 1206 kPa — Position
80 psi bidirectional indicator
VFF3PW1YCS 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs 2-position, 24 Vac solenoid Pneumatic 175 psi 1206 kPa — Position
80 psi spring return indicator
VFF3PW1YDR 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs 4-20 mA Servo 80 psi Pneumatic 175 psi 1206 kPa — Position
bidirectional indicator
VFF3PW1YDS 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs 4-20 mA Servo, 80 psi Pneumatic 175 psi 1206 kPa — Position
spring return indicator
VFF3PW1YER 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs 2-position, 120 Vac solenoid Pneumatic 175 psi 1206 kPa — Position
80 psi bidirectional indicator
VFF3PW1YES 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs 2-position, 120 Vac solenoid Pneumatic 175 psi 1206 kPa — Position
80 psi spring return indicator
VFF3PW1YPR 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs Modulating w/positioner, Pneumatic 175 psi 1206 kPa — Position
bidirectional indicator
VFF3PW1YPS 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs Modulating w/positioner, Pneumatic 175 psi 1206 kPa — Position
spring return indicator
VFF3PW1YXR 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs 2-position 80 psi Pneumatic 175 psi 1206 kPa — Position
bidirectional indicator
VFF3PW1YXS 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs 2-position, 80 psi spring Pneumatic 175 psi 1206 kPa — Position
return indicator
VFF3RV1YCR 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs 2-position, 24 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi bidirectional indicator
VFF3RV1YCS 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs 2-position, 24 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi spring return indicator
VFF3RV1YDR 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs 4-20 mA Servo 80 psi Pneumatic 50 psi 345 kPa — Position
bidirectional indicator
VFF3RV1YDS 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs 4-20 mA Servo, 80 psi Pneumatic 50 psi 345 kPa — Position
spring return indicator
VFF3RV1YER 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs 2-position, 120 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi bidirectional indicator
VFF3RV1YES 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs 2-position, 120 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi spring return indicator
VFF3RV1YPR 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs Modulating w/positioner, Pneumatic 50 psi 345 kPa — Position
bidirectional indicator
VFF3RV1YPS 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs Modulating w/positioner, Pneumatic 50 psi 345 kPa — Position
spring return indicator

626 customer.honeywell.com 70-6910


Butterfly Control Valves

Controls
Maximum

Home
Differential
Pressure
Capacity at 60 Capacity at 90 Ratings (Close-
Valve Size degrees stroke degrees stroke off)
Type of
Product Number (inch) (DN) (Cv) (Kv) (Cv) (Kv) Actuator Selection Enclosure (psi) (kPa) Comments Includes
VFF3RV1YXR 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs 2-position 80 psi Pneumatic 50 psi 345 kPa — Position
bidirectional indicator

Indoor Air Quality


VFF3RV1YXS 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs 2-position, 80 psi spring Pneumatic 50 psi 345 kPa — Position
return indicator
VFF3RW1YCR 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs 2-position, 24 Vac solenoid Pneumatic 150 psi 1034 kPa — Position
80 psi bidirectional indicator
VFF3RW1YCS 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs 2-position, 24 Vac solenoid Pneumatic 150 psi 1034 kPa — Position
80 psi spring return indicator
VFF3RW1YDR 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs 4-20 mA Servo 80 psi Pneumatic 150 psi 1034 kPa — Position
bidirectional indicator

Combustion Controls
VFF3RW1YDS 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs 4-20 mA Servo, 80 psi Pneumatic 150 psi 1034 kPa — Position
spring return indicator

Residential
VFF3RW1YER 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs 2-position, 120 Vac solenoid Pneumatic 150 psi 1034 kPa — Position
80 psi bidirectional indicator
VFF3RW1YES 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs 2-position, 120 Vac solenoid Pneumatic 150 psi 1034 kPa — Position
80 psi spring return indicator
VFF3RW1YPR 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs Modulating w/positioner, Pneumatic 150 psi 1034 kPa — Position
bidirectional indicator
VFF3RW1YPS 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs Modulating w/positioner, Pneumatic 150 psi 1034 kPa — Position

Hydronic Controls
spring return indicator
VFF3RW1YXR 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs 2-position 80 psi Pneumatic 150 psi 1034 kPa — Position
bidirectional indicator
VFF3RW1YXS 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs 2-position, 80 psi spring Pneumatic 150 psi 1034 kPa — Position
return indicator
VFF3SV1YCR 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs 2-position, 24 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi bidirectional indicator
VFF3SV1YCS 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs 2-position, 24 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi spring return indicator
VFF3SV1YDR 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs 4-20 mA Servo 80 psi Pneumatic 50 psi 345 kPa — Position

Controls
bidirectional indicator

Water
VFF3SV1YDS 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs 4-20 mA Servo, 80 psi Pneumatic 50 psi 345 kPa — Position
spring return indicator
VFF3SV1YER 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs 2-position, 120 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi bidirectional indicator
VFF3SV1YES 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs 2-position, 120 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi spring return indicator

Building Automation
VFF3SV1YPR 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs Modulating w/positioner, Pneumatic 50 psi 345 kPa — Position
bidirectional indicator
VFF3SV1YPS 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs Modulating w/positioner, Pneumatic 50 psi 345 kPa — Position
spring return indicator
VFF3SV1YXR 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs 2-position 80 psi Pneumatic 50 psi 345 kPa — Position
bidirectional indicator
VFF3SV1YXS 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs 2-position, 80 psi spring Pneumatic 50 psi 345 kPa — Position
return indicator
VFF3SW1YCR 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs 2-position, 24 Vac solenoid Pneumatic 150 psi 1034 kPa — Position
80 psi bidirectional indicator

Components
Commercial
VFF3SW1YDR 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs 4-20 mA Servo 80 psi Pneumatic 150 psi 1034 kPa — Position
bidirectional indicator
VFF3SW1YER 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs 2-position, 120 Vac solenoid Pneumatic 150 psi 1034 kPa — Position
80 psi bidirectional indicator
VFF3SW1YPR 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs Modulating w/positioner, Pneumatic 150 psi 1034 kPa — Position
bidirectional indicator
VFF3SW1YXR 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs 2-position 80 psi Pneumatic 150 psi 1034 kPa — Position
bidirectional indicator
Pneumatic Controls

VFF3TV1YCR 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs 2-position, 24 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi bidirectional indicator
VFF3TV1YCS 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs 2-position, 24 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi spring return indicator
VFF3TV1YDR 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs 4-20 mA Servo 80 psi Pneumatic 50 psi 345 kPa — Position
bidirectional indicator
VFF3TV1YDS 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs 4-20 mA Servo, 80 psi Pneumatic 50 psi 345 kPa — Position
spring return indicator
Industrial Combustion

VFF3TV1YER 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs 2-position, 120 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi bidirectional indicator
Controls

VFF3TV1YES 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs 2-position, 120 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi spring return indicator

70-6910 627
Butterfly Control Valves
Maximum
Differential
Pressure
Capacity at 60 Capacity at 90 Ratings (Close-
Valve Size degrees stroke degrees stroke off)
Type of
Product Number (inch) (DN) (Cv) (Kv) (Cv) (Kv) Actuator Selection Enclosure (psi) (kPa) Comments Includes
VFF3TV1YPR 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs Modulating w/positioner, Pneumatic 50 psi 345 kPa — Position
bidirectional indicator
VFF3TV1YPS 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs Modulating w/positioner, Pneumatic 50 psi 345 kPa — Position
spring return indicator
VFF3TV1YXR 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs 2-position 80 psi Pneumatic 50 psi 345 kPa — Position
bidirectional indicator
VFF3TV1YXS 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs 2-position, 80 psi spring Pneumatic 50 psi 345 kPa — Position
return indicator
VFF3TW1YCR 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs 2-position, 24 Vac solenoid Pneumatic 150 psi 1034 kPa — Position
80 psi bidirectional indicator
VFF3TW1YDR 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs 4-20 mA Servo 80 psi Pneumatic 150 psi 1034 kPa — Position
bidirectional indicator
VFF3TW1YER 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs 2-position, 120 Vac solenoid Pneumatic 150 psi 1034 kPa — Position
80 psi bidirectional indicator
VFF3TW1YPR 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs Modulating w/positioner, Pneumatic 150 psi 1034 kPa — Position
bidirectional indicator
VFF3TW1YXR 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs 2-position 80 psi Pneumatic 150 psi 1034 kPa — Position
bidirectional indicator
VFF3UV1YCR 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs 2-position, 24 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi bidirectional indicator
VFF3UV1YCS 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs 2-position, 24 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi spring return indicator
VFF3UV1YDR 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs 4-20 mA Servo 80 psi Pneumatic 50 psi 345 kPa — Position
bidirectional indicator
VFF3UV1YDS 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs 4-20 mA Servo, 80 psi Pneumatic 50 psi 345 kPa — Position
spring return indicator
VFF3UV1YER 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs 2-position, 120 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi bidirectional indicator
VFF3UV1YES 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs 2-position, 120 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi spring return indicator
VFF3UV1YPR 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs Modulating w/positioner, Pneumatic 50 psi 345 kPa — Position
bidirectional indicator
VFF3UV1YPS 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs Modulating w/positioner, Pneumatic 50 psi 345 kPa — Position
spring return indicator
VFF3UV1YXR 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs 2-position 80 psi Pneumatic 50 psi 345 kPa — Position
bidirectional indicator
VFF3UV1YXS 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs 2-position, 80 psi spring Pneumatic 50 psi 345 kPa — Position
return indicator
VFF3UW1YCR 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs 2-position, 24 Vac solenoid Pneumatic 150 psi 1034 kPa — Position
80 psi bidirectional indicator
VFF3UW1YDR 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs 4-20 mA Servo 80 psi Pneumatic 150 psi 1034 kPa — Position
bidirectional indicator
VFF3UW1YER 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs 2-position, 120 Vac solenoid Pneumatic 150 psi 1034 kPa — Position
80 psi bidirectional indicator
VFF3UW1YPR 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs Modulating w/positioner, Pneumatic 150 psi 1034 kPa — Position
bidirectional indicator
VFF3UW1YXR 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs 2-position 80 psi Pneumatic 150 psi 1034 kPa — Position
bidirectional indicator

**VFF50-0400 position status monitor for VFF butterfly valves with high pressure pneumatic actuators is available to be ordered separately or will be
assembled to the valve if ordered at the same time. It is compatible with any high pressure pneumatic actuators without pneumatic or electro-
pneumatic positioner (e.g. VFF...XR/XS, VFF...CR/CS, or VFF...ER/ES).

628 customer.honeywell.com 70-6910


Butterfly Control Valves
VFF6 Three-way (A-AB-B) Butterfly Control Valves

Controls
Home
Body Pattern: 3 way (A-AB-B porting)
Valve Action: Normally Closed
Connection Type: Lugged
Controlled Fluid: Chilled or hot water with up to 50% Glycol. Not for
use with steam or fuels.
Actuator Control Type: Electric floating

Indoor Air Quality


Type of Enclosure: NEMA 2 housing
Flow Characteristic: Modified Equal Percent
Mounting: ANSI Flanged
Static Pressure Rating (max): 250 psi (1724 kPa)
Actuator Ambient Temperature Ratings: -5 F to 140 F (-20 C to 60 C)
Temperature Range: -40 F to 250 F (-40 C to 121 C)
Number of Flange Bolts
For 2 in., 2-1/2 in., 3 in. valves: 4
For 4 in., 5 in., 6 in., 8 in., valves: 8

Combustion Controls
For 10 in., 12 in., 14 in. valves: 12
For 16 in., 18 in. valves: 16

Residential
For 20 in. valves: 20
Flange Bolt Thread
For 2 in., 2-1/2 in., 3 in. valves: 5/8 in.-11 pitch
For 4 in., 5 in., 6 in., 8 in., valves: 3/4 in.-10 pitch
For 10 in., 12 in., 14 in. valves: 7/8 in.-9 pitch
For 16 in., 18 in., 20 in. valves: 1-1/8 in.-7 pitch
Materials

Hydronic Controls
(Body): Polyester-coated cast iron ASTM A126 Class B
(Stem): 416 Stainless Steel
(Seat): Peroxide-cured EPDM resilient seat
(Plug/Ball/Disc): Nylon 11-coated ductile iron
Approvals:
CE: Compliant
Underwriters Laboratories, Inc. C/US UL873, Plenum Rated
Resilient seat three-way valves provide control for HVAC system
applications including chilled water, hot water, cooling tower Accessories:
water, and thermal storage systems. VFF50-0400 Position status monitor for VFF butterfly valves with high
pressure pneumatic actuators

Controls
Water
Valves with Electric Actuator

Maximum
Differential
Pressure
Capacity at 60 Capacity at 90 Ratings
Valve Size degrees stroke degrees stroke (Close-off)

Building Automation
Actuator Type of
Product Number (inch) (DN) (Cv) (Kv) (Cv) (Kv) Selection Enclosure (psi) (kPa) Comments Includes
VFF6FW1Y2A 2 in. DN50 61 Cv 53 kvs 144 Cv 125 kvs Non-Spring Return NEMA 2 housing 175 psi 1206 kPa — —
Floating control
VFF6FW1Y2B 2 in. DN50 61 Cv 53 kvs 144 Cv 125 kvs Non-Spring Return NEMA 2 housing 175 psi 1206 kPa — —
Modulating control
VFF6FW1Y2C 2 in. DN50 61 Cv 53 kvs 144 Cv 125 kvs Spring Return 2- NEMA 2 housing 175 psi 1206 kPa — —
Position, 24 Vac
VFF6FW1Y2D 2 in. DN50 61 Cv 53 kvs 144 Cv 125 kvs Spring Return NEMA 2 housing 175 psi 1206 kPa — —
Floating/Modulating

Components
control

Commercial
VFF6FW1Y2E 2 in. DN50 61 Cv 53 kvs 144 Cv 125 kvs Spring Return 2- NEMA 2 housing 175 psi 1206 kPa — —
Position, 120 Vac
VFF6FW1YXA 2 in. DN50 61 Cv 53 kvs 144 Cv 125 kvs Non-Spring Return NEMA 4X (Water 175 psi 1206 kPa — Anti-condensation
120 Vac Floating tight, corrosion- heater, manual
control proof) housing gear wheel
VFF6FW1YXB 2 in. DN50 61 Cv 53 kvs 144 Cv 125 kvs Non-Spring Return NEMA 4X (Water 175 psi 1206 kPa — Anti-condensation
Modulating control tight, corrosion- heater, manual
Pneumatic Controls

proof) housing gear wheel


VFF6GW1Y2A 2-1/2 in. DN65 107 Cv 93 kvs 282 Cv 244 kvs Non-Spring Return NEMA 2 housing 175 psi 1206 kPa — —
Floating control
VFF6GW1Y2B 2-1/2 in. DN65 107 Cv 93 kvs 282 Cv 244 kvs Non-Spring Return NEMA 2 housing 175 psi 1206 kPa — —
Modulating control
VFF6GW1Y2C 2-1/2 in. DN65 107 Cv 93 kvs 282 Cv 244 kvs Spring Return 2- NEMA 2 housing 175 psi 1206 kPa — —
Position, 24 Vac
VFF6GW1Y2D 2-1/2 in. DN65 107 Cv 93 kvs 282 Cv 244 kvs Spring Return NEMA 2 housing 175 psi 1206 kPa — —
Floating/Modulating
Industrial Combustion

control
VFF6GW1Y2E 2-1/2 in. DN65 107 Cv 93 kvs 282 Cv 244 kvs Spring Return 2- NEMA 2 housing 175 psi 1206 kPa — —
Controls

Position, 120 Vac

70-6910 629
Butterfly Control Valves
Maximum
Differential
Pressure
Capacity at 60 Capacity at 90 Ratings
Valve Size degrees stroke degrees stroke (Close-off)
Actuator Type of
Product Number (inch) (DN) (Cv) (Kv) (Cv) (Kv) Selection Enclosure (psi) (kPa) Comments Includes
VFF6GW1YXA 2-1/2 in. DN65 107 Cv 93 kvs 282 Cv 244 kvs Non-Spring Return NEMA 4X (Water 175 psi 1206 kPa — Anti-condensation
120 Vac Floating tight, corrosion- heater, manual
control proof) housing gear wheel
VFF6GW1YXB 2-1/2 in. DN65 107 Cv 93 kvs 282 Cv 244 kvs Non-Spring Return NEMA 4X (Water 175 psi 1206 kPa — Anti-condensation
Modulating control tight, corrosion- heater, manual
proof) housing gear wheel
VFF6HW1Y2A 3 in. DN80 154 Cv 133 kvs 461 Cv 399 kvs Non-Spring Return NEMA 2 housing 175 psi 1206 kPa — —
Floating control
VFF6HW1Y2B 3 in. DN80 154 Cv 133 kvs 461 Cv 399 kvs Non-Spring Return NEMA 2 housing 175 psi 1206 kPa — —
Modulating control
VFF6HW1Y2C 3 in. DN80 154 Cv 133 kvs 461 Cv 399 kvs Spring Return 2- NEMA 2 housing 175 psi 1206 kPa — —
Position, 24 Vac
VFF6HW1Y2D 3 in. DN80 154 Cv 133 kvs 461 Cv 399 kvs Spring Return NEMA 2 housing 175 psi 1206 kPa — —
Floating/Modulating
control
VFF6HW1Y2E 3 in. DN80 154 Cv 133 kvs 461 Cv 399 kvs Spring Return 2- NEMA 2 housing 175 psi 1206 kPa — —
Position, 120 Vac
VFF6HW1YXA 3 in. DN80 154 Cv 133 kvs 461 Cv 399 kvs Non-Spring Return NEMA 4X (Water 175 psi 1206 kPa — Anti-condensation
120 Vac Floating tight, corrosion- heater, manual
control proof) housing gear wheel
VFF6HW1YXB 3 in. DN80 154 Cv 133 kvs 461 Cv 399 kvs Non-Spring Return NEMA 4X (Water 175 psi 1206 kPa — Anti-condensation
Modulating control tight, corrosion- heater, manual
proof) housing gear wheel
VFF6JV1Y2A 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs Non-Spring Return NEMA 2 housing 50 psi 345 kPa — —
Floating control
VFF6JV1Y2B 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs Non-Spring Return NEMA 2 housing 50 psi 345 kPa — —
Modulating control
VFF6JV1Y2C 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs Spring Return 2- NEMA 2 housing 50 psi 345 kPa — —
Position, 24 Vac
VFF6JV1Y2D 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs Spring Return NEMA 2 housing 50 psi 345 kPa — —
Floating/Modulating
control
VFF6JV1Y2E 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs Spring Return 2- NEMA 2 housing 50 psi 345 kPa — —
Position, 120 Vac
VFF6JW1Y2A 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs Non-Spring Return NEMA 2 housing 175 psi 1206 kPa — —
Floating control
VFF6JW1Y2B 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs Non-Spring Return NEMA 2 housing 175 psi 1206 kPa — —
Modulating control
VFF6JW1YXA 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs Non-Spring Return NEMA 4X (Water 175 psi 1206 kPa — Anti-condensation
120 Vac Floating tight, corrosion- heater, manual
control proof) housing gear wheel
VFF6JW1YXB 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs Non-Spring Return NEMA 4X (Water 175 psi 1206 kPa — Anti-condensation
Modulating control tight, corrosion- heater, manual
proof) housing gear wheel
VFF6KV1Y2A 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs Non-Spring Return NEMA 2 housing 50 psi 345 kPa — —
Floating control
VFF6KV1Y2B 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs Non-Spring Return NEMA 2 housing 50 psi 345 kPa — —
Modulating control
VFF6KV1Y2C 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs Spring Return 2- NEMA 2 housing 50 psi 345 kPa Chilled water —
Position, 24 Vac service only
VFF6KV1Y2D 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs Spring Return NEMA 2 housing 50 psi 345 kPa Chilled water —
Floating/Modulating service only
control
VFF6KV1Y2E 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs Spring Return 2- NEMA 2 housing 50 psi 345 kPa Chilled water —
Position, 120 Vac service only
VFF6KW1Y2A 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs Non-Spring Return NEMA 2 housing 175 psi 1206 kPa — —
Floating control
VFF6KW1Y2B 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs Non-Spring Return NEMA 2 housing 175 psi 1206 kPa — —
Modulating control
VFF6KV1YXA 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs Non-Spring Return NEMA 4X (Water 50 psi 345 kPa — Anti-condensation
120 Vac Floating tight, corrosion- heater, manual
control proof) housing gear wheel
VFF6KV1YXB 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs Non-Spring Return NEMA 4X (Water 50 psi 345 kPa — Anti-condensation
Modulating control tight, corrosion- heater, manual
proof) housing gear wheel
VFF6KW1YXA 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs Non-Spring Return NEMA 4X (Water 175 psi 1206 kPa — Anti-condensation
120 Vac Floating tight, corrosion- heater, manual
control proof) housing gear wheel

630 customer.honeywell.com 70-6910


Butterfly Control Valves

Controls
Maximum

Home
Differential
Pressure
Capacity at 60 Capacity at 90 Ratings
Valve Size degrees stroke degrees stroke (Close-off)
Actuator Type of
Product Number (inch) (DN) (Cv) (Kv) (Cv) (Kv) Selection Enclosure (psi) (kPa) Comments Includes
VFF6KW1YXB 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs Non-Spring Return NEMA 4X (Water 175 psi 1206 kPa — Anti-condensation
Modulating control tight, corrosion- heater, manual

Indoor Air Quality


proof) housing gear wheel
VFF6LV1Y2A 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs Non-Spring Return NEMA 2 housing 50 psi 345 kPa — —
Floating control
VFF6LV1Y2B 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs Non-Spring Return NEMA 2 housing 50 psi 345 kPa — —
Modulating control
VFF6LV1YXA 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs Non-Spring Return NEMA 4X (Water 50 psi 345 kPa — Anti-condensation
120 Vac Floating tight, corrosion- heater, manual
control proof) housing gear wheel

Combustion Controls
VFF6LV1YXB 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs Non-Spring Return NEMA 4X (Water 50 psi 345 kPa — Anti-condensation
Modulating control tight, corrosion- heater, manual

Residential
proof) housing gear wheel
VFF6LW1YXA 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs Non-Spring Return NEMA 4X (Water 175 psi 1206 kPa — Anti-condensation
120 Vac Floating tight, corrosion- heater, manual
control proof) housing gear wheel
VFF6LW1YXB 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs Non-Spring Return NEMA 4X (Water 175 psi 1206 kPa — Anti-condensation
Modulating control tight, corrosion- heater, manual
proof) housing gear wheel
VFF6MV1YXA 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs Non-Spring Return NEMA 4X (Water 50 psi 345 kPa — Anti-condensation

Hydronic Controls
120 Vac Floating tight, corrosion- heater, manual
control proof) housing gear wheel
VFF6MV1YXB 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs Non-Spring Return NEMA 4X (Water 50 psi 345 kPa — Anti-condensation
Modulating control tight, corrosion- heater, manual
proof) housing gear wheel
VFF6MW1YXA 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs Non-Spring Return NEMA 4X (Water 175 psi 1206 kPa — Anti-condensation
120 Vac Floating tight, corrosion- heater, manual
control proof) housing gear wheel
VFF6MW1YXB 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs Non-Spring Return NEMA 4X (Water 175 psi 1206 kPa — Anti-condensation
Modulating control tight, corrosion- heater, manual
proof) housing gear wheel

Controls
Water
VFF6NV1YXA 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs Non-Spring Return NEMA 4X (Water 50 psi 345 kPa — Anti-condensation
120 Vac Floating tight, corrosion- heater, manual
control proof) housing gear wheel
VFF6NV1YXB 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs Non-Spring Return NEMA 4X (Water 50 psi 345 kPa — Anti-condensation
Modulating control tight, corrosion- heater, manual
proof) housing gear wheel
VFF6NW1YXA 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs Non-Spring Return NEMA 4X (Water 175 psi 1206 kPa — Anti-condensation

Building Automation
120 Vac Floating tight, corrosion- heater, manual
control proof) housing gear wheel
VFF6NW1YXB 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs Non-Spring Return NEMA 4X (Water 175 psi 1206 kPa — Anti-condensation
Modulating control tight, corrosion- heater, manual
proof) housing gear wheel
VFF6PV1YXA 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs Non-Spring Return NEMA 4X (Water 50 psi 345 kPa — Anti-condensation
120 Vac Floating tight, corrosion- heater, manual
control proof) housing gear wheel
VFF6PV1YXB 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs Non-Spring Return NEMA 4X (Water 50 psi 345 kPa — Anti-condensation
Modulating control tight, corrosion- heater, manual
proof) housing gear wheel

Components
Commercial
VFF6PW1YXA 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs Non-Spring Return NEMA 4X (Water 175 psi 1206 kPa — Anti-condensation
120 Vac Floating tight, corrosion- heater, manual
control proof) housing gear wheel
VFF6PW1YXB 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs Non-Spring Return NEMA 4X (Water 175 psi 1206 kPa — Anti-condensation
Modulating control tight, corrosion- heater, manual
proof) housing gear wheel
VFF6RW1Y4A 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs Non-Spring Return NEMA 4 (Water 150 psi 1034 kPa — Anti-condensation
Pneumatic Controls

120 Vac Floating tight) housing heater, manual


control gear wheel
VFF6RW1Y4B 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs Non-Spring Return NEMA 4 (Water 150 psi 1034 kPa — Anti-condensation
20 mA Modulating tight) housing heater, manual
control gear wheel
VFF6RV1YXA 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs Non-Spring Return NEMA 4X (Water 50 psi 345 kPa — Anti-condensation
120 Vac Floating tight, corrosion- heater, manual
control proof) housing gear wheel
VFF6RV1YXB 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs Non-Spring Return NEMA 4X (Water 50 psi 345 kPa — Anti-condensation
Industrial Combustion

Modulating control tight, corrosion- heater, manual


proof) housing gear wheel
VFF6SW1Y4A
Controls

16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs Non-Spring Return NEMA 4 (Water 150 psi 1034 kPa — Anti-condensation
120 Vac Floating tight) housing heater, manual
control gear wheel

70-6910 631
Butterfly Control Valves
Maximum
Differential
Pressure
Capacity at 60 Capacity at 90 Ratings
Valve Size degrees stroke degrees stroke (Close-off)
Actuator Type of
Product Number (inch) (DN) (Cv) (Kv) (Cv) (Kv) Selection Enclosure (psi) (kPa) Comments Includes
VFF6SW1Y4B 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs Non-Spring Return NEMA 4 (Water 150 psi 1034 kPa — Anti-condensation
20 mA Modulating tight) housing heater, manual
control gear wheel
VFF6SV1YXA 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs Non-Spring Return NEMA 4X (Water 50 psi 345 kPa — Anti-condensation
120 Vac Floating tight, corrosion- heater, manual
control proof) housing gear wheel
VFF6SV1YXB 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs Non-Spring Return NEMA 4X (Water 50 psi 345 kPa — Anti-condensation
Modulating control tight, corrosion- heater, manual
proof) housing gear wheel
VFF6TV1Y4A 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs Non-Spring Return NEMA 4 (Water 50 psi 345 kPa — Anti-condensation
120 Vac Floating tight) housing heater, manual
control gear wheel
VFF6TV1Y4B 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs Non-Spring Return NEMA 4 (Water 50 psi 345 kPa — Anti-condensation
20 mA Modulating tight) housing heater, manual
control gear wheel
VFF6TW1Y4A 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs Non-Spring Return NEMA 4 (Water 150 psi 1034 kPa — Anti-condensation
120 Vac Floating tight) housing heater, manual
control gear wheel
VFF6TW1Y4B 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs Non-Spring Return NEMA 4 (Water 150 psi 1034 kPa — Anti-condensation
20 mA Modulating tight) housing heater, manual
control gear wheel
VFF6UV1Y4A 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs Non-Spring Return NEMA 4 (Water 50 psi 345 kPa — Anti-condensation
120 Vac Floating tight) housing heater, manual
control gear wheel
VFF6UV1Y4B 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs Non-Spring Return NEMA 4 (Water 50 psi 345 kPa — Anti-condensation
20 mA Modulating tight) housing heater, manual
control gear wheel
VFF6UW1Y4A 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs Non-Spring Return NEMA 4 (Water 150 psi 1034 kPa — Anti-condensation
120 Vac Floating tight) housing heater, manual
control gear wheel
VFF6UW1Y4B 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs Non-Spring Return NEMA 4 (Water 150 psi 1034 kPa — Anti-condensation
20 mA Modulating tight) housing heater, manual
control gear wheel
Valves with Pneumatic Actuator

Maximum
Differential
Pressure
Capacity at 60 Capacity at 90 Ratings
Valve Size degrees stroke degrees stroke (Close-off)
Type of
Product Number (inch) (DN) (Cv) (Kv) (Cv) (Kv) Actuator Selection Enclosure (psi) (kPa) Comments Includes
VFF6FW1Y8P 2 in. DN50 61 Cv 53 kvs Stroke limited to 70 20 psi spring return Pneumatic 175 psi 1206 kPa Linear actuator —
degrees
VFF6FW1YCR 2 in. DN50 61 Cv 53 kvs 144 Cv 125 kvs 2-position, 24 Vac solenoid Pneumatic 175 psi 1206 kPa — Position
80 psi bidirectional indicator
VFF6FW1YCS 2 in. DN50 61 Cv 53 kvs 144 Cv 125 kvs 2-position, 24 Vac solenoid Pneumatic 175 psi 1206 kPa — Position
80 psi spring return indicator
VFF6FW1YDR 2 in. DN50 61 Cv 53 kvs 144 Cv 125 kvs 4-20 mA Servo 80 psi Pneumatic 175 psi 1206 kPa — Position
bidirectional indicator
VFF6FW1YDS 2 in. DN50 61 Cv 53 kvs 144 Cv 125 kvs 4-20 mA Servo, 80 psi spring Pneumatic 175 psi 1206 kPa — Position
return indicator
VFF6FW1YER 2 in. DN50 61 Cv 53 kvs 144 Cv 125 kvs 2-position, 120 Vac solenoid Pneumatic 175 psi 1206 kPa — Position
80 psi bidirectional indicator
VFF6FW1YPP 2 in. DN50 61 Cv 53 kvs Stroke limited to 70 Modulating w/positioner, Pneumatic 175 psi 1206 kPa Linear actuator —
degrees spring return
VFF6FW1YPR 2 in. DN50 61 Cv 53 kvs 144 Cv 125 kvs Modulating w/positioner, Pneumatic 175 psi 1206 kPa — Position
bidirectional indicator
VFF6FW1YPS 2 in. DN50 61 Cv 53 kvs 144 Cv 125 kvs Modulating w/positioner, Pneumatic 175 psi 1206 kPa — Position
spring return indicator
VFF6FW1YXR 2 in. DN50 61 Cv 53 kvs 144 Cv 125 kvs 2-position 80 psi bidirectional Pneumatic 175 psi 1206 kPa — Position
indicator
VFF6FW1YXS 2 in. DN50 61 Cv 53 kvs 144 Cv 125 kvs 2-position, 80 psi spring Pneumatic 175 psi 1206 kPa — Position
return indicator
VFF6GW1Y8P 2-1/2 in. DN65 107 Cv 93 kvs Stroke limited to 70 20 psi spring return Pneumatic 175 psi 1206 kPa Linear actuator —
degrees
VFF6GW1YCR 2-1/2 in. DN65 107 Cv 93 kvs 282 Cv 244 kvs 2-position, 24 Vac solenoid Pneumatic 175 psi 1206 kPa — Position
80 psi bidirectional indicator

632 customer.honeywell.com 70-6910


Butterfly Control Valves

Controls
Maximum

Home
Differential
Pressure
Capacity at 60 Capacity at 90 Ratings
Valve Size degrees stroke degrees stroke (Close-off)
Type of
Product Number (inch) (DN) (Cv) (Kv) (Cv) (Kv) Actuator Selection Enclosure (psi) (kPa) Comments Includes
VFF6GW1YCS 2-1/2 in. DN65 107 Cv 93 kvs 282 Cv 244 kvs 2-position, 24 Vac solenoid Pneumatic 175 psi 1206 kPa — Position
80 psi spring return indicator

Indoor Air Quality


VFF6GW1YDR 2-1/2 in. DN65 107 Cv 93 kvs 282 Cv 244 kvs 4-20 mA Servo 80 psi Pneumatic 175 psi 1206 kPa — Position
bidirectional indicator
VFF6GW1YDS 2-1/2 in. DN65 107 Cv 93 kvs 282 Cv 244 kvs 4-20 mA Servo, 80 psi spring Pneumatic 175 psi 1206 kPa — Position
return indicator
VFF6GW1YER 2-1/2 in. DN65 107 Cv 93 kvs 282 Cv 244 kvs 2-position, 120 Vac solenoid Pneumatic 175 psi 1206 kPa — Position
80 psi bidirectional indicator
VFF6GW1YES 2-1/2 in. DN65 107 Cv 93 kvs 282 Cv 244 kvs 2-position, 120 Vac solenoid Pneumatic 175 psi 1206 kPa — Position
80 psi spring return indicator

Combustion Controls
VFF6GW1YPP 2-1/2 in. DN65 107 Cv 93 kvs Stroke limited to 70 Modulating w/positioner, Pneumatic 175 psi 1206 kPa Linear actuator —
degrees spring return

Residential
VFF6GW1YPR 2-1/2 in. DN65 107 Cv 93 kvs 282 Cv 244 kvs Modulating w/positioner, Pneumatic 175 psi 1206 kPa — Position
bidirectional indicator
VFF6GW1YPS 2-1/2 in. DN65 107 Cv 93 kvs 282 Cv 244 kvs Modulating w/positioner, Pneumatic 175 psi 1206 kPa — Position
spring return indicator
VFF6GW1YXR 2-1/2 in. DN65 107 Cv 93 kvs 282 Cv 244 kvs 2-position 80 psi bidirectional Pneumatic 175 psi 1206 kPa — Position
indicator
VFF6GW1YXS 2-1/2 in. DN65 107 Cv 93 kvs 282 Cv 244 kvs 2-position, 80 psi spring Pneumatic 175 psi 1206 kPa — Position

Hydronic Controls
return indicator
VFF6HW1Y8P 3 in. DN80 154 Cv 133 kvs Stroke limited to 70 20 psi spring return Pneumatic 175 psi 1206 kPa Linear actuator —
degrees
VFF6HW1YCR 3 in. DN80 154 Cv 133 kvs 461 Cv 399 kvs 2-position, 24 Vac solenoid Pneumatic 175 psi 1206 kPa — Position
80 psi bidirectional indicator
VFF6HW1YCS 3 in. DN80 154 Cv 133 kvs 461 Cv 399 kvs 2-position, 24 Vac solenoid Pneumatic 175 psi 1206 kPa — Position
80 psi spring return indicator
VFF6HW1YDR 3 in. DN80 154 Cv 133 kvs 461 Cv 399 kvs 4-20 mA Servo 80 psi Pneumatic 175 psi 1206 kPa — Position
bidirectional indicator
VFF6HW1YDS 3 in. DN80 154 Cv 133 kvs 461 Cv 399 kvs 4-20 mA Servo, 80 psi spring Pneumatic 175 psi 1206 kPa — Position

Controls
return indicator

Water
VFF6HW1YER 3 in. DN80 154 Cv 133 kvs 461 Cv 399 kvs 2-position, 120 Vac solenoid Pneumatic 175 psi 1206 kPa — Position
80 psi bidirectional indicator
VFF6HW1YES 3 in. DN80 154 Cv 133 kvs 461 Cv 399 kvs 2-position, 120 Vac solenoid Pneumatic 175 psi 1206 kPa — Position
80 psi spring return indicator
VFF6HW1YPP 3 in. DN80 154 Cv 133 kvs Stroke limited to 70 Modulating w/positioner, Pneumatic 175 psi 1206 kPa Linear actuator —
degrees spring return

Building Automation
VFF6HW1YPR 3 in. DN80 154 Cv 133 kvs 461 Cv 399 kvs Modulating w/positioner, Pneumatic 175 psi 1206 kPa — Position
bidirectional indicator
VFF6HW1YPS 3 in. DN80 154 Cv 133 kvs 461 Cv 399 kvs Modulating w/positioner, Pneumatic 175 psi 1206 kPa — Position
spring return indicator
VFF6HW1YXR 3 in. DN80 154 Cv 133 kvs 461 Cv 399 kvs 2-position 80 psi bidirectional Pneumatic 175 psi 1206 kPa — Position
indicator
VFF6HW1YXS 3 in. DN80 154 Cv 133 kvs 461 Cv 399 kvs 2-position, 80 psi spring Pneumatic 175 psi 1206 kPa — Position
return indicator
VFF6JV1Y8P 4 in. DN100 274 Cv 237 kvs Stroke limited to 70 20 psi spring return Pneumatic 50 psi 345 kPa Linear actuator —
degrees

Components
Commercial
VFF6JV1YCR 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs 2-position, 24 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi bidirectional indicator
VFF6JV1YCS 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs 2-position, 24 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi spring return indicator
VFF6JV1YDR 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs 4-20 mA Servo 80 psi Pneumatic 50 psi 345 kPa — Position
bidirectional indicator
VFF6JV1YDS 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs 4-20 mA Servo, 80 psi spring Pneumatic 50 psi 345 kPa — Position
return indicator
Pneumatic Controls

VFF6JV1YER 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs 2-position, 120 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi bidirectional indicator
VFF6JV1YES 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs 2-position, 120 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi spring return indicator
VFF6JV1YPP 4 in. DN100 274 Cv 237 kvs Stroke limited to 70 Modulating w/positioner, Pneumatic 50 psi 345 kPa Linear actuator —
degrees spring return
VFF6JV1YPR 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs Modulating w/positioner, Pneumatic 50 psi 345 kPa — Position
bidirectional indicator
Industrial Combustion

VFF6JV1YPS 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs Modulating w/positioner, Pneumatic 50 psi 345 kPa — Position
spring return indicator
Controls

VFF6JV1YXR 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs 2-position 80 psi bidirectional Pneumatic 50 psi 345 kPa — Position
indicator

70-6910 633
Butterfly Control Valves
Maximum
Differential
Pressure
Capacity at 60 Capacity at 90 Ratings
Valve Size degrees stroke degrees stroke (Close-off)
Type of
Product Number (inch) (DN) (Cv) (Kv) (Cv) (Kv) Actuator Selection Enclosure (psi) (kPa) Comments Includes
VFF6JV1YXS 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs 2-position, 80 psi spring Pneumatic 50 psi 345 kPa — Position
return indicator
VFF6JW1Y8P 4 in. DN100 274 Cv 237 kvs Stroke limited to 70 20 psi spring return Pneumatic 175 psi 1206 kPa Linear actuator —
degrees
VFF6JW1YCR 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs 2-position, 24 Vac solenoid Pneumatic 175 psi 1206 kPa — Position
80 psi bidirectional indicator
VFF6JW1YCS 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs 2-position, 24 Vac solenoid Pneumatic 175 psi 1206 kPa — Position
80 psi spring return indicator
VFF6JW1YDR 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs 4-20 mA Servo 80 psi Pneumatic 175 psi 1206 kPa — Position
bidirectional indicator
VFF6JW1YDS 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs 4-20 mA Servo, 80 psi spring Pneumatic 175 psi 1206 kPa — Position
return indicator
VFF6JW1YER 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs 2-position, 120 Vac solenoid Pneumatic 175 psi 1206 kPa — Position
80 psi bidirectional indicator
VFF6JW1YES 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs 2-position, 120 Vac solenoid Pneumatic 175 psi 1206 kPa — Position
80 psi spring return indicator
VFF6JW1YPP 4 in. DN100 274 Cv 237 kvs Stroke limited to 70 Modulating w/positioner, Pneumatic 175 psi 1206 kPa Linear actuator —
degrees spring return
VFF6JW1YPR 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs Modulating w/positioner, Pneumatic 175 psi 1206 kPa — Position
bidirectional indicator
VFF6JW1YPS 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs Modulating w/positioner, Pneumatic 175 psi 1206 kPa — Position
spring return indicator
VFF6JW1YXR 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs 2-position 80 psi bidirectional Pneumatic 175 psi 1206 kPa — Position
indicator
VFF6JW1YXS 4 in. DN100 274 Cv 237 kvs 841 Cv 727 kvs 2-position, 80 psi spring Pneumatic 175 psi 1206 kPa — Position
return indicator
VFF6KV1YCR 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs 2-position, 24 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi bidirectional indicator
VFF6KV1YCS 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs 2-position, 24 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi spring return indicator
VFF6KV1YDR 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs 4-20 mA Servo 80 psi Pneumatic 50 psi 345 kPa — Position
bidirectional indicator
VFF6KV1YDS 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs 4-20 mA Servo, 80 psi spring Pneumatic 50 psi 345 kPa — Position
return indicator
VFF6KV1YER 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs 2-position, 120 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi bidirectional indicator
VFF6KV1YES 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs 2-position, 120 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi spring return indicator
VFF6KV1YPR 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs Modulating w/positioner, Pneumatic 50 psi 345 kPa — Position
bidirectional indicator
VFF6KV1YPS 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs Modulating w/positioner, Pneumatic 50 psi 345 kPa — Position
spring return indicator
VFF6KV1YXR 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs 2-position 80 psi bidirectional Pneumatic 50 psi 345 kPa — Position
indicator
VFF6KV1YXS 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs 2-position, 80 psi spring Pneumatic 50 psi 345 kPa — Position
return indicator
VFF6KW1Y8P 5 in. DN125 428 Cv 370 kvs Stroke limited to 70 20 psi spring return Pneumatic 175 psi 1206 kPa Linear actuator —
degrees
VFF6KW1YCR 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs 2-position, 24 Vac solenoid Pneumatic 175 psi 1206 kPa — Position
80 psi bidirectional indicator
VFF6KW1YCS 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs 2-position, 24 Vac solenoid Pneumatic 175 psi 1206 kPa — Position
80 psi spring return indicator
VFF6KW1YDR 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs 4-20 mA Servo 80 psi Pneumatic 175 psi 1206 kPa — Position
bidirectional indicator
VFF6KW1YDS 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs 4-20 mA Servo, 80 psi spring Pneumatic 175 psi 1206 kPa — Position
return indicator
VFF6KW1YER 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs 2-position, 120 Vac solenoid Pneumatic 175 psi 1206 kPa — Position
80 psi bidirectional indicator
VFF6KW1YES 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs 2-position, 120 Vac solenoid Pneumatic 175 psi 1206 kPa — Position
80 psi spring return indicator
VFF6KW1YPP 5 in. DN125 428 Cv 370 kvs Stroke limited to 70 Modulating w/positioner, Pneumatic 175 psi 1206 kPa Linear actuator —
degrees spring return
VFF6KW1YPR 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs Modulating w/positioner, Pneumatic 175 psi 1206 kPa — Position
bidirectional indicator
VFF6KW1YPS 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs Modulating w/positioner, Pneumatic 175 psi 1206 kPa — Position
spring return indicator

634 customer.honeywell.com 70-6910


Butterfly Control Valves

Controls
Maximum

Home
Differential
Pressure
Capacity at 60 Capacity at 90 Ratings
Valve Size degrees stroke degrees stroke (Close-off)
Type of
Product Number (inch) (DN) (Cv) (Kv) (Cv) (Kv) Actuator Selection Enclosure (psi) (kPa) Comments Includes
VFF6KW1YXR 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs 2-position 80 psi bidirectional Pneumatic 175 psi 1206 kPa — Position
indicator

Indoor Air Quality


VFF6KW1YXS 5 in. DN125 428 Cv 370 kvs 1376 Cv 1190 kvs 2-position, 80 psi spring Pneumatic 175 psi 1206 kPa — Position
return indicator
VFF6LV1Y8P 6 in. DN150 567 Cv 490 kvs Stroke limited to 70 20 psi spring return Pneumatic 50 psi 345 kPa Linear actuator —
degrees
VFF6LV1YCR 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs 2-position, 24 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi bidirectional indicator
VFF6LV1YCS 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs 2-position, 24 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi spring return indicator

Combustion Controls
VFF6LV1YDR 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs 4-20 mA Servo 80 psi Pneumatic 50 psi 345 kPa — Position
bidirectional indicator

Residential
VFF6LV1YDS 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs 4-20 mA Servo, 80 psi spring Pneumatic 50 psi 345 kPa — Position
return indicator
VFF6LV1YER 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs 2-position, 120 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi bidirectional indicator
VFF6LV1YES 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs 2-position, 120 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi spring return indicator
VFF6LV1YPP 6 in. DN150 567 Cv 490 kvs Stroke limited to 70 Modulating w/positioner, Pneumatic 50 psi 345 kPa Linear actuator —

Hydronic Controls
degrees spring return
VFF6LV1YPR 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs Modulating w/positioner, Pneumatic 50 psi 345 kPa — Position
bidirectional indicator
VFF6LV1YPS 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs Modulating w/positioner, Pneumatic 50 psi 345 kPa — Position
spring return indicator
VFF6LV1YXR 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs 2-position 80 psi bidirectional Pneumatic 50 psi 345 kPa — Position
indicator
VFF6LV1YXS 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs 2-position, 80 psi spring Pneumatic 50 psi 345 kPa — Position
return indicator
VFF6LW1Y8P 6 in. DN150 567 Cv 490 kvs Stroke limited to 70 20 psi spring return Pneumatic 175 psi 1206 kPa Linear actuator —

Controls
degrees

Water
VFF6LW1YCR 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs 2-position, 24 Vac solenoid Pneumatic 175 psi 1206 kPa — Position
80 psi bidirectional indicator
VFF6LW1YCS 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs 2-position, 24 Vac solenoid Pneumatic 175 psi 1206 kPa — Position
80 psi spring return indicator
VFF6LW1YDR 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs 4-20 mA Servo 80 psi Pneumatic 175 psi 1206 kPa — Position
bidirectional indicator

Building Automation
VFF6LW1YDS 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs 4-20 mA Servo, 80 psi spring Pneumatic 175 psi 1206 kPa — Position
return indicator
VFF6LW1YER 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs 2-position, 120 Vac solenoid Pneumatic 175 psi 1206 kPa — Position
80 psi bidirectional indicator
VFF6LW1YES 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs 2-position, 120 Vac solenoid Pneumatic 175 psi 1206 kPa — Position
80 psi spring return indicator
VFF6LW1YPP 6 in. DN150 567 Cv 490 kvs Stroke limited to 70 Modulating w/positioner, Pneumatic 175 psi 1206 kPa Linear actuator —
degrees spring return
VFF6LW1YPR 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs Modulating w/positioner, Pneumatic 175 psi 1206 kPa — Position
bidirectional indicator

Components
Commercial
VFF6LW1YPS 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs Modulating w/positioner, Pneumatic 175 psi 1206 kPa — Position
spring return indicator
VFF6LW1YXR 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs 2-position 80 psi bidirectional Pneumatic 175 psi 1206 kPa — Position
indicator
VFF6LW1YXS 6 in. DN150 567 Cv 490 kvs 1850 Cv 1600 kvs 2-position, 80 psi spring Pneumatic 175 psi 1206 kPa — Position
return indicator
VFF6MV1Y8P 8 in. DN200 1081 Cv 935 kvs Stroke limited to 70 20 psi spring return Pneumatic 50 psi 345 kPa Linear actuator —
degrees
Pneumatic Controls

VFF6MV1YCR 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs 2-position, 24 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi bidirectional indicator
VFF6MV1YCS 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs 2-position, 24 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi spring return indicator
VFF6MV1YDR 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs 4-20 mA Servo 80 psi Pneumatic 50 psi 345 kPa — Position
bidirectional indicator
VFF6MV1YDS 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs 4-20 mA Servo, 80 psi spring Pneumatic 50 psi 345 kPa — Position
return indicator
Industrial Combustion

VFF6MV1YER 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs 2-position, 120 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi bidirectional indicator
Controls

VFF6MV1YES 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs 2-position, 120 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi spring return indicator

70-6910 635
Butterfly Control Valves
Maximum
Differential
Pressure
Capacity at 60 Capacity at 90 Ratings
Valve Size degrees stroke degrees stroke (Close-off)
Type of
Product Number (inch) (DN) (Cv) (Kv) (Cv) (Kv) Actuator Selection Enclosure (psi) (kPa) Comments Includes
VFF6MV1YPP 8 in. DN200 1081 Cv 935 kvs Stroke limited to 70 Modulating w/positioner, Pneumatic 50 psi 345 kPa Linear actuator —
degrees spring return
VFF6MV1YPR 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs Modulating w/positioner, Pneumatic 50 psi 345 kPa — Position
bidirectional indicator
VFF6MV1YPS 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs Modulating w/positioner, Pneumatic 50 psi 345 kPa — Position
spring return indicator
VFF6MV1YXR 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs 2-position 80 psi bidirectional Pneumatic 50 psi 345 kPa — Position
indicator
VFF6MV1YXS 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs 2-position, 80 psi spring Pneumatic 50 psi 345 kPa — Position
return indicator
VFF6MW1YCR 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs 2-position, 24 Vac solenoid Pneumatic 175 psi 1206 kPa — Position
80 psi bidirectional indicator
VFF6MW1YCS 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs 2-position, 24 Vac solenoid Pneumatic 175 psi 1206 kPa — Position
80 psi spring return indicator
VFF6MW1YDR 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs 4-20 mA Servo 80 psi Pneumatic 175 psi 1206 kPa — Position
bidirectional indicator
VFF6MW1YDS 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs 4-20 mA Servo, 80 psi spring Pneumatic 175 psi 1206 kPa — Position
return indicator
VFF6MW1YER 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs 2-position, 120 Vac solenoid Pneumatic 175 psi 1206 kPa — Position
80 psi bidirectional indicator
VFF6MW1YES 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs 2-position, 120 Vac solenoid Pneumatic 175 psi 1206 kPa — Position
80 psi spring return indicator
VFF6MW1YPR 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs Modulating w/positioner, Pneumatic 175 psi 1206 kPa — Position
bidirectional indicator
VFF6MW1YPS 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs Modulating w/positioner, Pneumatic 175 psi 1206 kPa — Position
spring return indicator
VFF6MW1YXR 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs 2-position 80 psi bidirectional Pneumatic 175 psi 1206 kPa — Position
indicator
VFF6MW1YXS 8 in. DN200 1081 Cv 935 kvs 3316 Cv 2868 kvs 2-position, 80 psi spring Pneumatic 175 psi 1206 kPa — Position
return indicator
VFF6NV1YCR 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs 2-position, 24 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi bidirectional indicator
VFF6NV1YCS 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs 2-position, 24 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi spring return indicator
VFF6NV1YDR 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs 4-20 mA Servo 80 psi Pneumatic 50 psi 345 kPa — Position
bidirectional indicator
VFF6NV1YDS 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs 4-20 mA Servo, 80 psi spring Pneumatic 50 psi 345 kPa — Position
return indicator
VFF6NV1YER 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs 2-position, 120 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi bidirectional indicator
VFF6NV1YES 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs 2-position, 120 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi spring return indicator
VFF6NV1YPR 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs Modulating w/positioner, Pneumatic 50 psi 345 kPa — Position
bidirectional indicator
VFF6NV1YPS 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs Modulating w/positioner, Pneumatic 50 psi 345 kPa — Position
spring return indicator
VFF6NV1YXR 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs 2-position 80 psi bidirectional Pneumatic 50 psi 345 kPa — Position
indicator
VFF6NV1YXS 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs 2-position, 80 psi spring Pneumatic 50 psi 345 kPa — Position
return indicator
VFF6NW1YCR 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs 2-position, 24 Vac solenoid Pneumatic 175 psi 1206 kPa — Position
80 psi bidirectional indicator
VFF6NW1YCS 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs 2-position, 24 Vac solenoid Pneumatic 175 psi 1206 kPa — Position
80 psi spring return indicator
VFF6NW1YDR 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs 4-20 mA Servo 80 psi Pneumatic 175 psi 1206 kPa — Position
bidirectional indicator
VFF6NW1YDS 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs 4-20 mA Servo, 80 psi spring Pneumatic 175 psi 1206 kPa — Position
return indicator
VFF6NW1YER 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs 2-position, 120 Vac solenoid Pneumatic 175 psi 1206 kPa — Position
80 psi bidirectional indicator
VFF6NW1YES 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs 2-position, 120 Vac solenoid Pneumatic 175 psi 1206 kPa — Position
80 psi spring return indicator
VFF6NW1YPR 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs Modulating w/positioner, Pneumatic 175 psi 1206 kPa — Position
bidirectional indicator
VFF6NW1YPS 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs Modulating w/positioner, Pneumatic 175 psi 1206 kPa — Position
spring return indicator

636 customer.honeywell.com 70-6910


Butterfly Control Valves

Controls
Maximum

Home
Differential
Pressure
Capacity at 60 Capacity at 90 Ratings
Valve Size degrees stroke degrees stroke (Close-off)
Type of
Product Number (inch) (DN) (Cv) (Kv) (Cv) (Kv) Actuator Selection Enclosure (psi) (kPa) Comments Includes
VFF6NW1YXR 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs 2-position 80 psi bidirectional Pneumatic 175 psi 1206 kPa — Position
indicator

Indoor Air Quality


VFF6NW1YXS 10 in. DN250 1710 Cv 1479 kvs 5430 Cv 4697 kvs 2-position, 80 psi spring Pneumatic 175 psi 1206 kPa — Position
return indicator
VFF6PV1YCR 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs 2-position, 24 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi bidirectional indicator
VFF6PV1YCS 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs 2-position, 24 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi spring return indicator
VFF6PV1YDR 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs 4-20 mA Servo 80 psi Pneumatic 50 psi 345 kPa — Position
bidirectional indicator

Combustion Controls
VFF6PV1YDS 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs 4-20 mA Servo, 80 psi spring Pneumatic 50 psi 345 kPa — Position
return indicator

Residential
VFF6PV1YER 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs 2-position, 120 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi bidirectional indicator
VFF6PV1YES 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs 2-position, 120 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi spring return indicator
VFF6PV1YPR 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs Modulating w/positioner, Pneumatic 50 psi 345 kPa — Position
bidirectional indicator
VFF6PV1YPS 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs Modulating w/positioner, Pneumatic 50 psi 345 kPa — Position

Hydronic Controls
spring return indicator
VFF6PV1YXR 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs 2-position 80 psi bidirectional Pneumatic 50 psi 345 kPa — Position
indicator
VFF6PV1YXS 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs 2-position, 80 psi spring Pneumatic 50 psi 345 kPa — Position
return indicator
VFF6PW1YCR 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs 2-position, 24 Vac solenoid Pneumatic 175 psi 1206 kPa — Position
80 psi bidirectional indicator
VFF6PW1YCS 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs 2-position, 24 Vac solenoid Pneumatic 175 psi 1206 kPa — Position
80 psi spring return indicator
VFF6PW1YDR 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs 4-20 mA Servo 80 psi Pneumatic 175 psi 1206 kPa — Position

Controls
bidirectional indicator

Water
VFF6PW1YDS 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs 4-20 mA Servo, 80 psi spring Pneumatic 175 psi 1206 kPa — Position
return indicator
VFF6PW1YER 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs 2-position, 120 Vac solenoid Pneumatic 175 psi 1206 kPa — Position
80 psi bidirectional indicator
VFF6PW1YES 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs 2-position, 120 Vac solenoid Pneumatic 175 psi 1206 kPa — Position
80 psi spring return indicator

Building Automation
VFF6PW1YPR 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs Modulating w/positioner, Pneumatic 175 psi 1206 kPa — Position
bidirectional indicator
VFF6PW1YPS 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs Modulating w/positioner, Pneumatic 175 psi 1206 kPa — Position
spring return indicator
VFF6PW1YXR 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs 2-position 80 psi bidirectional Pneumatic 175 psi 1206 kPa — Position
indicator
VFF6PW1YXS 12 in. DN300 2563 Cv 2217 kvs 8077 Cv 6987 kvs 2-position, 80 psi spring Pneumatic 175 psi 1206 kPa — Position
return indicator
VFF6RV1YCR 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs 2-position, 24 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi bidirectional indicator

Components
Commercial
VFF6RV1YCS 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs 2-position, 24 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi spring return indicator
VFF6RV1YDR 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs 4-20 mA Servo 80 psi Pneumatic 50 psi 345 kPa — Position
bidirectional indicator
VFF6RV1YDS 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs 4-20 mA Servo, 80 psi spring Pneumatic 50 psi 345 kPa — Position
return indicator
VFF6RV1YER 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs 2-position, 120 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi bidirectional indicator
Pneumatic Controls

VFF6RV1YES 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs 2-position, 120 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi spring return indicator
VFF6RV1YPR 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs Modulating w/positioner, Pneumatic 50 psi 345 kPa — Position
bidirectional indicator
VFF6RV1YPS 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs Modulating w/positioner, Pneumatic 50 psi 345 kPa — Position
spring return indicator
VFF6RV1YXR 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs 2-position 80 psi bidirectional Pneumatic 50 psi 345 kPa — Position
indicator
Industrial Combustion

VFF6RV1YXS 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs 2-position, 80 psi spring Pneumatic 50 psi 345 kPa — Position
return indicator
Controls

VFF6RW1YCR 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs 2-position, 24 Vac solenoid Pneumatic 150 psi 1034 kPa — Position
80 psi bidirectional indicator

70-6910 637
Butterfly Control Valves
Maximum
Differential
Pressure
Capacity at 60 Capacity at 90 Ratings
Valve Size degrees stroke degrees stroke (Close-off)
Type of
Product Number (inch) (DN) (Cv) (Kv) (Cv) (Kv) Actuator Selection Enclosure (psi) (kPa) Comments Includes
VFF6RW1YCS 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs 2-position, 24 Vac solenoid Pneumatic 150 psi 1034 kPa — Position
80 psi spring return indicator
VFF6RW1YDR 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs 4-20 mA Servo 80 psi Pneumatic 150 psi 1034 kPa — Position
bidirectional indicator
VFF6RW1YDS 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs 4-20 mA Servo, 80 psi spring Pneumatic 150 psi 1034 kPa — Position
return indicator
VFF6RW1YER 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs 2-position, 120 Vac solenoid Pneumatic 150 psi 1034 kPa — Position
80 psi bidirectional indicator
VFF6RW1YES 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs 2-position, 120 Vac solenoid Pneumatic 150 psi 1034 kPa — Position
80 psi spring return indicator
VFF6RW1YPR 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs Modulating w/positioner, Pneumatic 150 psi 1034 kPa — Position
bidirectional indicator
VFF6RW1YPS 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs Modulating w/positioner, Pneumatic 150 psi 1034 kPa — Position
spring return indicator
VFF6RW1YXR 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs 2-position 80 psi bidirectional Pneumatic 150 psi 1034 kPa — Position
indicator
VFF6RW1YXS 14 in. DN350 3384 Cv 2927 kvs 10538 Cv 9115 kvs 2-position, 80 psi spring Pneumatic 150 psi 1034 kPa — Position
return indicator
VFF6SV1YCR 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs 2-position, 24 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi bidirectional indicator
VFF6SV1YCS 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs 2-position, 24 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi spring return indicator
VFF6SV1YDR 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs 4-20 mA Servo 80 psi Pneumatic 50 psi 345 kPa — Position
bidirectional indicator
VFF6SV1YDS 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs 4-20 mA Servo, 80 psi spring Pneumatic 50 psi 345 kPa — Position
return indicator
VFF6SV1YER 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs 2-position, 120 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi bidirectional indicator
VFF6SV1YES 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs 2-position, 120 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi spring return indicator
VFF6SV1YPR 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs Modulating w/positioner, Pneumatic 50 psi 345 kPa — Position
bidirectional indicator
VFF6SV1YPS 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs Modulating w/positioner, Pneumatic 50 psi 345 kPa — Position
spring return indicator
VFF6SV1YXR 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs 2-position 80 psi bidirectional Pneumatic 50 psi 345 kPa — Position
indicator
VFF6SV1YXS 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs 2-position, 80 psi spring Pneumatic 50 psi 345 kPa — Position
return indicator
VFF6SW1YCR 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs 2-position, 24 Vac solenoid Pneumatic 150 psi 1034 kPa — Position
80 psi bidirectional indicator
VFF6SW1YDR 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs 4-20 mA Servo 80 psi Pneumatic 150 psi 1034 kPa — Position
bidirectional indicator
VFF6SW1YER 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs 2-position, 120 Vac solenoid Pneumatic 150 psi 1034 kPa — Position
80 psi bidirectional indicator
VFF6SW1YPR 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs Modulating w/positioner, Pneumatic 150 psi 1034 kPa — Position
bidirectional indicator
VFF6SW1YXR 16 in. DN400 4483 Cv 3878 kvs 13966 Cv 12081 kvs 2-position 80 psi bidirectional Pneumatic 150 psi 1034 kPa — Position
indicator
VFF6TV1YCR 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs 2-position, 24 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi bidirectional indicator
VFF6TV1YCS 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs 2-position, 24 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi spring return indicator
VFF6TV1YDR 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs 4-20 mA Servo 80 psi Pneumatic 50 psi 345 kPa — Position
bidirectional indicator
VFF6TV1YDS 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs 4-20 mA Servo, 80 psi spring Pneumatic 50 psi 345 kPa — Position
return indicator
VFF6TV1YER 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs 2-position, 120 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi bidirectional indicator
VFF6TV1YES 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs 2-position, 120 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi spring return indicator
VFF6TV1YPR 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs Modulating w/positioner, Pneumatic 50 psi 345 kPa — Position
bidirectional indicator
VFF6TV1YPS 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs Modulating w/positioner, Pneumatic 50 psi 345 kPa — Position
spring return indicator
VFF6TV1YXR 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs 2-position 80 psi bidirectional Pneumatic 50 psi 345 kPa — Position
indicator

638 customer.honeywell.com 70-6910


Butterfly Control Valves

Controls
Maximum

Home
Differential
Pressure
Capacity at 60 Capacity at 90 Ratings
Valve Size degrees stroke degrees stroke (Close-off)
Type of
Product Number (inch) (DN) (Cv) (Kv) (Cv) (Kv) Actuator Selection Enclosure (psi) (kPa) Comments Includes
VFF6TV1YXS 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs 2-position, 80 psi spring Pneumatic 50 psi 345 kPa — Position
return indicator

Indoor Air Quality


VFF6TW1YCR 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs 2-position, 24 Vac solenoid Pneumatic 150 psi 1034 kPa — Position
80 psi bidirectional indicator
VFF6TW1YDR 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs 4-20 mA Servo 80 psi Pneumatic 150 psi 1034 kPa — Position
bidirectional indicator
VFF6TW1YER 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs 2-position, 120 Vac solenoid Pneumatic 150 psi 1034 kPa — Position
80 psi bidirectional indicator
VFF6TW1YPR 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs Modulating w/positioner, Pneumatic 150 psi 1034 kPa — Position
bidirectional indicator

Combustion Controls
VFF6TW1YXR 18 in. DN450 5736 Cv 4962 kvs 17214 Cv 14890 kvs 2-position 80 psi bidirectional Pneumatic 150 psi 1034 kPa — Position
indicator

Residential
VFF6UV1YCR 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs 2-position, 24 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi bidirectional indicator
VFF6UV1YCS 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs 2-position, 24 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi spring return indicator
VFF6UV1YDR 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs 4-20 mA Servo 80 psi Pneumatic 50 psi 345 kPa — Position
bidirectional indicator
VFF6UV1YDS 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs 4-20 mA Servo, 80 psi spring Pneumatic 50 psi 345 kPa — Position

Hydronic Controls
return indicator
VFF6UV1YER 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs 2-position, 120 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi bidirectional indicator
VFF6UV1YES 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs 2-position, 120 Vac solenoid Pneumatic 50 psi 345 kPa — Position
80 psi spring return indicator
VFF6UV1YPR 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs Modulating w/positioner, Pneumatic 50 psi 345 kPa — Position
bidirectional indicator
VFF6UV1YPS 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs Modulating w/positioner, Pneumatic 50 psi 345 kPa — Position
spring return indicator
VFF6UV1YXR 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs 2-position 80 psi bidirectional Pneumatic 50 psi 345 kPa — Position

Controls
indicator

Water
VFF6UV1YXS 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs 2-position, 80 psi spring Pneumatic 50 psi 345 kPa — Position
return indicator
VFF6UW1YCR 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs 2-position, 24 Vac solenoid Pneumatic 150 psi 1034 kPa — Position
80 psi bidirectional indicator
VFF6UW1YDR 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs 4-20 mA Servo 80 psi Pneumatic 150 psi 1034 kPa — Position
bidirectional indicator

Building Automation
VFF6UW1YER 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs 2-position, 120 Vac solenoid Pneumatic 150 psi 1034 kPa — Position
80 psi bidirectional indicator
VFF6UW1YPR 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs Modulating w/positioner, Pneumatic 150 psi 1034 kPa — Position
bidirectional indicator
VFF6UW1YXR 20 in. DN500 7144 Cv 6180 kvs 22339 Cv 19323 kvs 2-position 80 psi bidirectional Pneumatic 150 psi 1034 kPa — Position
indicator

**VFF50-0400 position status monitor for VFF butterfly valves with high pressure pneumatic actuators is available to be ordered separately or will be
assembled to the valve if ordered at the same time. It is compatible with any high pressure pneumatic actuators without pneumatic or electro-
pneumatic positioner (e.g. VFF...XR/XS, VFF...CR/CS, or VFF...ER/ES).

Components
Commercial
Butterfly Valve Assembly Accessories
Product Number Description Used With
VFF50-0400 Position status monitor for VFF butterfly valves with high VFF...XR/XS; VFF...ER/ES; VFF...CR/CS; High pressure pneumatic
pressure pneumatic actuators actuator without pneumatic or electro-pneumatic positioner
Pneumatic Controls
Industrial Combustion
Controls

70-6910 639
Flanged Globe Valves
V5011A,B Two-Way Flanged Globe Valves
Used for proportional control of hot or chilled water and glycol
solutions (to 50 percent concentration) and for two-position
control of low pressure steam in closed loop HVAC systems.
• Sizes range from 2-1/2 to 6 inches.
• Stainless steel stem with serviceable Teflon packing.
• Valves utilize direct mounting valve actuators, Q5020/Q5022
linkages with Direct Coupled Actuators, or Pneumatic Valve
Actuators to operate the valve.
• Equal Percentage flow characteristic.

Dimensions in inches (millimeters)


Valve Type: Globe Valve
Body Pattern: Two-way
I Connection Type: Flanged
Flow Characteristic: Equal percentage
Controlled Fluid: Chilled or hot water with up to 50% Glycol. Not for
A use with fuels; Low pressure steam
Maximum Safe Operating Pressure: 15 psi steam (100 kPa steam);
J
150 psi at 240 F water (1034 kPa at 115 C water)
Maximum Differential for Quiet Water Service: 20 psid (138 kPa)
G
Ambient Temperature Range: 40 F to 250 F (4 C to 121 C)
B H ANSI/ASME Rating: 125
E
Actuation: Must be purchased separately
F Materials
(Body): Cast Iron
C (Stem): 316 Stainless Steel
(Seat): Bronze
(Packing): Teflon Cone
D

J
MODEL VALVE Aa B C D E F G H
I
SIZE (TRAVEL) (DIAMETER)
2-1/2 3-1/2 4-13/16 4 9-1/2 7 2-1/2 3/4 5-1/2 3/4 1-3/8
(64) (89) (122) (102) (241) (178) (64) (19) (140) (19) (35)
3-1/2 3-1/2 4-5/8 11 7-1/2 3 3/4 6 3/4 1-3/8
V5011A 3 (76) (89) (89) (117) (279) (191) (76) (19) (152) (19) (35)
4 5-1/4 5-1/4 5-3/16 13 9 4 3/4 7-1/2 1-1/2 1-7/8
(102) (133) (133) (132) (330) (229) (102) (19) (191) (38) (48)
4 6-3/4 6-3/4 8-1/16 13 9 4 3/4 7-1/2 1-1/2 1-7/8
V5011B (102) (171) (171) (205) (330) (229) (102) (19) (191) (38) (48)
M27256

Valve Size Flow Capacity Stem Travel Bonnet Size


Valve
Product Number (inch) DN (Cv) (Kv) (inch) (mm) (inch) (mm) Action Used With
V5011A1734 2 1/2 in. DN65 63 Cv 54 kvs 3/4 in. 20 mm 1-3/8 in. 35 mm Stem down Q5001/Modutrol IV Motor; MP953; ML6420,21A,25;
to close ML7420/ML7421A/ML7425; ML6984/ML7984
V5011A1767 3 in. DN80 100 Cv 85 kvs 3/4 in. 20 mm 1-3/8 in. 35 mm Stem down ML6984/ML7984; ML7420/ML7421A/ML7425;
to close ML6420,21A,25; Q5001/Modutrol IV Motor; MP953
V5011A1858 4 in. DN100 160 Cv 137 kvs 1 1/2 in. 38 mm 1-7/8 in. 47.6 mm Stem down Q5001/Modutrol IV Motor; MP953; ML7421B;
to close ML6421B
V5011B1013 4 in. DN100 160 Cv 137 kvs 1 1/2 in. 38 mm 1-7/8 in. 47.6 mm Stem up to ML7421B; Q5001/Modutrol IV Motor; MP953;
close ML6421B
V5011A1882 5 in. DN125 250 Cv 214 kvs 1 1/2 in. 38 mm 1-7/8 in. 47.6 mm Stem down ML6421B; ML7421B; Q5001/Modutrol IV Motor;
to close MP953
V5011B1047 5 in. DN125 250 Cv 214 kvs 1 1/2 in. 38 mm 1-7/8 in. 47.6 mm Stem up to ML6421B; ML7421B; Q5001/Modutrol IV Motor;
close MP953
V5011A1916 6 in. DN150 360 Cv 308 kvs 1 1/2 in. 38 mm 1-7/8 in. 47.6 mm Stem down ML6421B; Q5001/Modutrol IV Motor; MP953;
to close ML7421B
V5011B1070 6 in. DN150 360 Cv 308 kvs 1 1/2 in. 38 mm 1-7/8 in. 47.6 mm Stem up to ML6421B; Q5001/Modutrol IV Motor; MP953;
close ML7421B

640 customer.honeywell.com 70-6910


Flanged Globe Valves
VGF2 Two-way Flanged Globe Valves

Controls
Home
Pneumatic Actuators, Modutrol™ Motors with Q5001 valve linkage,
or MN/MS Series Direct Coupled Actuators with Q5020 or Q5022
valve linkages.
• ANSI Class 125 and Class 250 cast iron bodies with flanged end
connections
• Equal percentage and linear flow characteristics
• Face-to-face flange dimensions per ANSI/ISA S75.03 standard

Indoor Air Quality


• Sizes from 2-1/2 to 6 in.
• Stainless steel trim standard for long life span
• ANSI Class III or IV seat leakage
• Steam inlet pressure up to 125 psig and 353 F maximum
temperature
• Self-adjusting packing
• Accurate positioning with equal percentage and linear flow
characteristics to ensure precise temperature control
• Universal bonnet for direct-coupled electric and pneumatic actuators

Combustion Controls
VGF Flanged Globe Valves are used for 2-position or modulating for easy mounting, or linkage coupled Modutrol™ Motors and MN/
control of steam, hot water, or chilled water-glycol solutions up to MS Series direct coupled actuators.

Residential
50 percent concentration in closed loop heating, ventilation and air • Not suitable for combustible gasses.
conditioning (HVAC) systems. They can be operated by ML6984/
7984, ML6420/6425, ML6421/7421 Electric Linear Actuators, MP953

Dimensions in inches (millimeters)


Valve Type: Globe Valve
Valve Action: Stem down to close
Body Pattern: Two-way

Hydronic Controls
STROKE Y Connection Type: Flanged
Controlled Fluid: Steam; Chilled or hot water with up to 50% Glycol.
Not for use with fuels
D
Fluid Temperature Range: 20 F to 250 F, steam 353 F (-7 C to +120 C,
steam 180 C)
Actuation: Must be purchased separately
B Stem Travel
2-1/2 and 3 inch valves: 3/4 in. (20 mm)
4 to 6 inch valves: 1-1/2 in. (39 mm)
Bonnet Size

Controls
2-1/2 and 3 inch valves: 1-3/8 in. (35 mm)

Water
4 to 6 inch valves: 1-7/8 in. (47.6 mm)
C
Materials
(Body): Cast Iron ASTM A126 Class B
(Stem): Stainless Steel
A (Seat): Stainless Steel
(Cartridge): Stainless Steel

Building Automation
1 DOTTED LINE REPRESENTS ANSI 125 VALVE BONNET.
(Plug/Ball/Disc): Stainless Steel
DIMENSIONS, IN. (MM) (Packing): Spring-loaded PTFE cone rings
MODEL
NUMBER A B C E Y

2-WAY VALVES, ANSI CLASS 125. STEM DOWN TO CLOSE. EQUAL


PERCENTAGE OR LINEAR FLOW CHARACTERISTIC

VGF21_S25 10-7/8 (276) 4-3/8 (112) 7 (178) 3-1/2 (89) 13/16 (20)
VGF21_S30 11-3/4 (298) 6-3/8 (161) 7-1/2 (191)

VGF21_S40 13-7/8 (352) 5-7/8 (150) 9 (229) 5-1/4 (133) 1-1/2 (38)

Components
Commercial
VGF21_S50 15-3/4 (400) 6-3/16 (157) 10 (254)

VGF21_S60 17-3/4 (451) 6-3/16 (157) 11 (279)

2-WAY VALVES, ANSI CLASS 250. STEM DOWN TO CLOSE. EQUAL


PERCENTAGE FLOW CHARACTERISTIC

VGF22ES25 11-1/2 (292) 4-3/8 (112) 7-1/2 (191) 3-1/2 (89) 13/16 (20)

VGF22ES30 12-1/2 (318) 6-3/8 (161) 8-1/4 (210)


Pneumatic Controls

VGF22ES40 14-1/2 (368) 5-7/8 (150) 10 (254) 5-1/4 (133) 1-1/2 (38)

VGF22ES50 16-5/8 (422) 6-3/16 (157) 11 (279)

VGF22ES60 18-5/8 (473) 6-3/16 (157) 12-1/2 (318)

2-WAY VALVES, PRESSURE-BALANCED, ANSI CLASS 125. STEM DOWN TO


CLOSE. EQUAL PERCENTAGE OR LINEAR FLOW CHARACTERISTIC

VGF21_P25 10-7/8 (276) 4-3/16 (107) 7 (178) 3-1/2 (89) 13/16 (20)
VGF21_P30 11-3/4 (298) 5-7/8 (150) 7-1/2 (191)
Industrial Combustion

VGF21_P40 13-7/8 (352) 5-7/8 (150) 9 (229) 5-1/4 (133) 1-1/2 (38)
VGF21_P50 15-3/4 (400) 6-1/8 (156) 10 (254)
Controls

VGF21_P60 17-3/4 (451) 6-1/8 (156) 11 (279)


M27603

70-6910 641
Flanged Globe Valves
Valves with Equal Percentage Flow Characteristic

Maximum Safe Maximum


Flow Operating Close-off
Valve Size Capacity Pressure ANSI/ Pressure
ASME Leakage
Product Number (inch) DN (Cv) (Kv) (psi) (kPa) Rating (psi) (kPa) Comments Used With Rating
VGF21EP25 2 1/2 in. DN65 70 Cv 60 kvs 175 psig 1206 kPA 125 175 psi 1206 kPa Pressure-balanced. MP953 (7-1/8 to 0.01% of
Minimum actuator 13"); ML6984/ Cv
force is 135# ML7984;
(600N)Direct acting ML642X/ML742X
VGF21ES25 2 1/2 in. DN65 70 Cv 60 kvs 175 psig 1206 kPA 125 69 psi 475 kPa Direct acting ML6420/21A/25; 0.05% of
ML7420/21A/25; Cv
Q5020/DCA;
VGF22ES25 2 1/2 in. DN65 70 Cv 60 kvs 400 psig 2758 kPA 250 69 psi 475 kPa Direct acting Q5001/Modutrol 0.05% of
IV Motor; MP953 Cv

VGF21EP30 3 in. DN80 115 Cv 99 kvs 175 psig 1206 kPA 125 175 psi 1206 kPa Pressure-balanced. MP953 (7-1/8 to 0.01% of
Minimum actuator 13"); ML6984/ Cv
force is 135# ML7984;
(600N)Direct acting ML642X/ML742X
VGF21ES30 3 in. DN80 115 Cv 99 kvs 175 psig 1206 kPA 125 34 psi 234 kPa Direct acting ML6420/21A/25; 0.05% of
ML7420/21A/25; Cv
Q5020/DCA;
VGF22ES30 3 in. DN80 120 Cv 103 kvs 400 psig 2758 kPA 250 34 psi 234 kPa Direct acting Q5001/Modutrol 0.05% of
IV Motor; MP953 Cv

VGF21EP40 4 in. DN100 150 Cv 129 kvs 175 psig 1206 kPA 125 175 psi 1206 kPa Pressure-balanced. ML6421B/ 0.01% of
Minimum actuator ML7421B, Cv
force is 400# MP953(13")
(1800N)Direct
acting
VGF21ES40 4 in. DN100 150 Cv 129 kvs 175 psig 1206 kPA 125 34 psi 234 kPa Direct acting ML6421B; 0.05% of
ML7421B; Cv
Q5001/Modutrol
VGF22ES40 4 in. DN100 150 Cv 129 kvs 400 psig 2758 kPA 250 34 psi 234 kPa Direct acting IV Motor; MP953 0.05% of
Cv
VGF21EP50 5 in. DN125 285 Cv 244 kvs 175 psig 1206 kPA 125 175 psi 1206 kPa Pressure-balanced. ML6421B/ 0.01% of
Minimum actuator ML7421B, Cv
force is 400# MP953(13")
(1800N)Direct
acting
VGF21ES50 5 in. DN125 285 Cv 244 kvs 175 psig 1206 kPA 125 13 psi 90 kPa Direct acting ML6421B; 0.05% of
ML7421B; Cv
Q5001/Modutrol
VGF22ES50 5 in. DN125 320 Cv 274 kvs 400 psig 2758 kPA 250 13 psi 90 kPa Direct acting IV Motor; MP953 0.05% of
Cv
VGF21EP60 6 in. DN150 365 Cv 313 kvs 175 psig 1206 kPA 125 175 psi 1206 kPa Pressure-balanced. ML6421B/ 0.01% of
Minimum actuator ML7421B, Cv
force is 400# MP953(13")
(1800N)Direct
acting
VGF21ES60 6 in. DN150 365 Cv 313 kvs 175 psig 1206 kPA 125 13 psi 90 kPa Direct acting ML6421B; 0.05% of
ML7421B; Cv
Q5001/Modutrol
VGF22ES60 6 in. DN150 370 Cv 317 kvs 400 psig 2758 kPA 250 13 psi 90 kPa Direct acting IV Motor; MP953 0.05% of
Cv

642 customer.honeywell.com 70-6910


Flanged Globe Valves
Valves with Linear Flow Characteristic

Controls
Home
Maximum Safe Operating Pressure: 175 psig (1206 kPA)

Maximum
Flow Close-off
Valve Size Capacity ANSI/ Pressure
ASME Leakage
Product Number (inch) DN (Cv) (Kv) Rating (psi) (kPa) Comments Used With Rating

Indoor Air Quality


VGF21LP25 2 1/2 in. DN65 70 Cv 60 kvs 125 175 psi 1206 kPa Pressure-balanced. MP953 (7-1/8 to 13"); ML6984/ 0.01% of Cv
Minimum actuator force is ML7984; ML642X/ML742X
135# (600N)Direct acting
VGF21LS25 2 1/2 in. DN65 70 Cv 60 kvs 125 69 psi 475 kPa Direct acting ML6420/21A/25; ML7420/21A/ 0.05% of Cv
25; Q5020/DCA; Q5001/
Modutrol IV Motor; MP953
VGF21LP30 3 in. DN80 120 Cv 103 kvs 125 175 psi 1206 kPa Pressure-balanced. MP953 (7-1/8 to 13"); ML6984/ 0.01% of Cv
Minimum actuator force is ML7984; ML642X/ML742X
135# (600N)Direct acting

Combustion Controls
VGF21LS30 3 in. DN80 125 Cv 107 kvs 125 34 psi 234 kPa Direct acting ML6420/21A/25; ML7420/21A/ 0.05% of Cv

Residential
25; Q5020/DCA; Q5001/
Modutrol IV Motor; MP953
VGF21LP40 4 in. DN100 150 Cv 129 kvs 125 175 psi 1206 kPa Pressure-balanced. ML6421B/ML7421B, 0.01% of Cv
Minimum actuator force is MP953(13")
400# (1800N)Direct acting
VGF21LS40 4 in. DN100 155 Cv 133 kvs 125 34 psi 234 kPa Direct acting ML6421B; ML7421B; Q5001/ 0.05% of Cv
Modutrol IV Motor; MP953

Hydronic Controls
VGF21LP50 5 in. DN125 320 Cv 274 kvs 125 175 psi 1206 kPa Pressure-balanced. ML6421B/ML7421B, 0.01% of Cv
Minimum actuator force is MP953(13")
400# (1800N)Direct acting
VGF21LS50 5 in. DN125 320 Cv 274 kvs 125 13 psi 90 kPa Direct acting ML6421B; ML7421B; Q5001/ 0.05% of Cv
Modutrol IV Motor; MP953
VGF21LP60 6 in. DN150 370 Cv 317 kvs 125 175 psi 1206 kPa Pressure-balanced. ML6421B/ML7421B, 0.01% of Cv
Minimum actuator force is MP953(13")
400# (1800N)Direct acting
VGF21LS60 6 in. DN150 370 Cv 317 kvs 125 13 psi 90 kPa Direct acting ML6421B; ML7421B; Q5001/ 0.05% of Cv
Modutrol IV Motor; MP953

Controls
Water
Building Automation
Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 643
Flanged Globe Valves
V5013B,C Three-Way Flanged Globe Valves
The V5013B are three-way mixing valves. The V5013C are three-
way diverting valves. These valves provide proportional or two-
position control of hot or chilled water in closed loop heating or
cooling systems. These valves are offered in sizes 2 1/2 in. through
6 in.
• Not suitable for combustible gases.
• Valves utilize direct mounting valve actuators, Q5020/Q5022
linkages with Direct Coupled Actuators, or Pneumatic Valve
Actuators to operate the valve.
• Constant total flow through full plug travel.
• Stainless steel stem prevents corrosion.
• Class IV (0.01% of Cv) Leakage Rating.

Dimensions in inches (millimeters)


Valve Type: Globe Valve
Body Pattern: Three-way
Flow Characteristic: Linear (constant total)
BONNET Connection Type: Flanged
Controlled Fluid: Chilled or hot water with up to 50% Glycol. Not for
use with steam or fuels.
E Maximum Safe Operating Pressure: 150 psi at 240 F water (1034 kPa
at 115 C water)
A
F Maximum Differential for Quiet Water Service: 20 psid (138 kPa)
Ambient Temperature Range: 40 F to 250 F (4 C to 121 C)
D ANSI/ASME Rating: 125
Actuation: Must be purchased separately
B Materials
(Body): Cast Iron
(Stem): Stainless Steel
(Seat): Bronze
(Packing): Teflon Cone
C G

V5013B,C DIMENSIONS
VALVE SIZE IN INCHES (MM)
2-1/2 (64) 3 (76) 4 (102) 5 (125) 6 (152)
A 4-1/2 5-1/4 5-7/8 6-1/4 7-1/4
(114) (133) (149) (159) (184)
B 6-7/17 6-5/8 8-11/16 9-5/8 10-11/16
(164) (168) (221) (244) (271)
C 9-1/2 11 13 15 16-1/2
(241) (279) (330) (381) (419)
D 2-1/2 3 4 5 6
(64) (76) (102) (127) (152)
E 3/4 3/4 3/4 7/8 7/8
(19) (19) (19) (22) (22)
F 5-1/2 6 7-1/2 8-1/2 9-1/2
(140) (152) (191) (216) (241)
G 7 7-1/2 9 10 11
(178) (191) (229) (254) (279)

NUMBER OF
VALVE SIZE BONNET SIZE
BOLT HOLES
2-1/2 (64)
1-3/8 (35) 4
3 (76)
4 (102)
5 (125) 1-7/8 (48) 8
6 (152)
C7959B

644 customer.honeywell.com 70-6910


Flanged Globe Valves

Controls
Home
Flow
Valve Size Capacity Stem Travel Bonnet Size
Valve
Product Number (inch) DN (Cv) (Kv) (inch) (mm) (inch) (mm) Action Comments Used With
V5013B1003 2 1/2 in. DN65 63 Cv 54 kvs 3/4 in. 20 mm 1-3/8 in. 35 mm Stem up Mixing ML6984/ML7984; Q5001/Modutrol
increases B IV Motor; ML7420/ML7421A/
to AB flow ML7425; ML6420,21A,25

Indoor Air Quality


V5013C1001 2 1/2 in. DN65 63 Cv 54 kvs 3/4 in. 20 mm 1-3/8 in. 35 mm Stem up Diverting ML6984/ML7984; Q5001/Modutrol
increases IV Motor; ML7420/ML7421A/
AB to A flow ML7425; ML6420,21A,25
V5013B1011 3 in. DN80 100 Cv 85 kvs 3/4 in. 20 mm 1-3/8 in. 35 mm Stem up Mixing ML6984/ML7984; Q5001/Modutrol
increases B IV Motor; ML6420,21A,25; ML7420/
to AB flow ML7421A/ML7425
V5013C1019 3 in. DN80 100 Cv 85 kvs 3/4 in. 20 mm 1-3/8 in. 35 mm Stem up Diverting ML6984/ML7984; Q5001/Modutrol
increases IV Motor; ML6420,21A,25; ML7420/
AB to A flow ML7421A/ML7425

Combustion Controls
V5013B1029 4 in. DN100 160 Cv 137 kvs 1 1/2 in. 38 mm 1-7/8 in. 47.6 mm Stem up Mixing ML7421B; ML6421B; Q5001/

Residential
increases B Modutrol IV Motor
to AB flow
V5013C1027 4 in. DN100 160 Cv 137 kvs 1 1/2 in. 38 mm 1-7/8 in. 47.6 mm Stem up Diverting ML6421B; ML7421B; Q5001/
increases Modutrol IV Motor
AB to A flow
V5013B1037 5 in. DN125 250 Cv 214 kvs 1 1/2 in. 38 mm 1-7/8 in. 47.6 mm Stem up Mixing ML6421B; ML7421B; Q5001/
increases B Modutrol IV Motor
to AB flow

Hydronic Controls
V5013C1035 5 in. DN125 250 Cv 214 kvs 1 1/2 in. 38 mm 1-7/8 in. 47.6 mm Stem up Diverting ML7421B; ML6421B; Q5001/
increases Modutrol IV Motor
AB to A flow
V5013B1045 6 in. DN150 360 Cv 308 kvs 1 1/2 in. 38 mm 1-7/8 in. 47.6 mm Stem up Mixing ML7421B; ML6421B; Q5001/
increases B Modutrol IV Motor
to AB flow
V5013C1043 6 in. DN150 360 Cv 308 kvs 1 1/2 in. 38 mm 1-7/8 in. 47.6 mm Stem up Diverting ML6421B; ML7421B; Q5001/
increases Modutrol IV Motor
AB to A flow

Controls
Water
Building Automation
Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 645
Flanged Globe Valves
VGF3 Three-way Flanged Globe Valves
valve linkages. Three-way bodies are available in mixing or
diverting style with equal percentage and linear flow
characteristics, respectively. For boiler/chiller bypass applications
requiring tight close-off, use VGF31/32LD diverting valves. For
outdoor temperature compensation of building supply water, or
modulating control of heat exchangers, use VGF31/32EM mixing
valves.
• ANSI Class 125 and Class 250 cast iron bodies with flanged end
connections.
• Face-to-face flange dimensions per ANSI/ISA S75.03 standard.
• Sizes from 2-1/2 to 6 inches.
• Stainless steel trim standard for long life span.
• Self-adjusting packing.
• Accurate positioning with equal percentage and linear flow
VGF Flanged Globe Valves are used for 2-position or modulating characteristics to ensure precise temperature control.
control of hot water or chilled water-glycol solutions up to 50% • Universal bonnet for direct-coupled electric and pneumatic actuators
concentration in closed loop heating, ventilation and air for easy mounting, or linkage coupled Modutrol™ Motors and MN/
conditioning (HVAC) systems. They can be operated by ML6984/ MS Series direct coupled actuators.
7984, ML6420/6425, ML6421/7421 Electric Linear Actuators, MP953 • Constant total flow throughout full plug travel (3-way diverting
Pneumatic Actuators, Modutrol™ Motors with Q5001 valve linkage, models).
or MN/MS Series Direct Coupled Actuators with Q5020 or Q5022 • Not suitable for combustible gasses.

Dimensions in inches (millimeters)

DIMENSIONS, IN. (MM)


STROKE Y MODEL
NUMBER A B C D E Y

3-WAY MIXING VALVES, ANSI CLASS 125. STEM UP TO CLOSE A-AB


E
VGF31EM25 10-7/8 (276) 3 (76) 7 (178) 3-3/4 (95) 4-3/16 (107) 13/16 (20)

VGF31EM30 11-3/4 (298) 4-3/16 (107) 7-1/2 (191) 4-3/8 (111)


VGF31EM40 13-7/8 (352) 5-8/16 (140) 9 (229) 5-1/8 (130) 6-11/16 (170) 1-1/2 (38)

VGF31EM50 15-3/4 (400) 5-3/8 (137) 10 (254) 5-3/4 (146)


1 B
VGF31EM60 17-3/4 (451) 5-11/16 (145) 11 (279) 6-5/8 (168)

3-WAY MIXING VALVES, ANSI CLASS 250. STEM UP TO CLOSE A-AB


C
VGF32EM25 11-1/2 (292) 4-3/8 (112) 7-1/2 (191) 3-3/4 (95) 4-3/16 (107) 13/16 (20)
D VGF32EM30 12-1/2 (318) 6-3/8 (161) 8-1/4 (210) 4-3/8 (111)
VGF32EM40 14-1/2 (368) 5-7/8 (150) 10 (254) 5-1/8 (130) 6-11/16 (170) 1-1/2 (38)

VGF32EM50 16-5/8 (422) 6-3/16 (157) 11 (279) 5-3/4 (146)


A
VGF32EM60 18-5/8 (473) 6-3/16 (157) 12-1/2 (318) 6-5/8 (168)
1 DOTTED LINE REPRESENTS ANSI 125 3-WAY DIVERTING VALVES, ANSI CLASS 125. STEM DOWN TO CLOSE AB-A
VALVE BONNET.
VGF31LD25 10-7/8 (276) 3 (76) 7 (178) 3-3/4 (95) 4-3/16 (107) 13/16 (20)

VGF31LD30 11-3/4 (298) 4-3/16 (107) 7-1/2 (191) 4-3/8 (111)

VGF31LD40 13-7/8 (352) 5-8/16 (140) 9 (229) 5-1/8 (130) 6-11/16 (170) 1-1/2 (38)

VGF31LD50 15-3/4 (400) 5-3/8 (137) 10 (254) 5-3/4 (146)

VGF31LD60 17-3/4 (451) 5-11/16 (145) 11 (279) 6-5/8 (168)

3-WAY DIVERTING VALVES, ANSI CLASS 250. STEM DOWN TO CLOSE AB-A

VGF32LD25 11-1/2 (292) 4-3/8 (112) 7-1/2 (191) 3-3/4 (95) 4-3/16 (107) 13/16 (20)

VGF32LD30 12-1/2 (318) 6-3/8 (161) 8-1/4 (210) 4-3/8 (111)

VGF32LD40 14-1/2 (368) 5-7/8 (150) 10 (254) 5-1/8 (130) 6-11/16 (170) 1-1/2 (38)

VGF32LD50 16-5/8 (422) 6-3/16 (157) 11 (279) 5-3/4 (146)

VGF32LD60 18-5/8 (473) 6-3/16 (157) 12-1/2 (318) 6-5/8 (168)


M27604

Stem Travel
Valve Type: Globe Valve 2-1/2 and 3 inch valves3/4 in. (20 mm)
Body Pattern: Three-way 4 to 6 inch valves:1-1/2 in. (39 mm)
Connection Type: Flanged
Bonnet Size
Controlled Fluid: Chilled or hot water with up to 50% Glycol. Not for
2-1/2 and 3 inch valves: 1-3/8 in. (35 mm)
use with steam or fuels.
4 to 6 inch valves: 1-7/8 in. (47.6 mm)
Leakage Rating: Port A seat leakage: 0.5%; Port B seat leakage 1.0%.
Maximum Safe Operating Pressure: 175 psig at 130 F (66 C) (1206 Materials
kPa at 66 C (130 F)) (Body): Cast Iron ASTM A126 Class B
Maximum Differential Pressure Ratings (Close-off): 87 psi (599 kPa) (Stem): Stainless Steel
Fluid Temperature Range: 20 F to 250 F (-7 C to +120 C) (Seat): Stainless Steel
Actuation: Must be purchased separately (Cartridge): Stainless Steel
(Plug/Ball/Disc): Stainless Steel
(Packing): Spring-loaded PTFE cone rings

646 customer.honeywell.com 70-6910


Flanged Globe Valves
Valves with Equal Percentage (A-AB) Flow Characteristic

Controls
Home
Note: For Supply mixing control; use diverting value for boiler/chiller bypass
Valve Action: Mixing, step up to close A-AB
Comments: Stem up to close A-AB

Maximum
Maximum Safe Close-off
Valve Size Flow Capacity Operating Pressure ANSI/ Pressure
ASME

Indoor Air Quality


Product Number (inch) DN (Cv) (Kv) (psi) (kPa) Rating (psi) (kPa) Used With
VGF31EM25 2 1/2 in. DN65 70 Cv 60 kvs 175 psig at 1206 kPa at 125 87 psi 599 kPa ML6984/ML7984; ML6420/21A/25;
130 F (66 C) 66 C (130 F) ML7420/21A/25; Q5020/DCA; Q5001/
Modutrol IV Motor; MP953
VGF32EM25 2 1/2 in. DN65 70 Cv 60 kvs 400 psig 2758 kPA 250 87 psi 599 kPa ML6984/ML7984; ML6420/21A/25;
ML7420/21A/25; Q5020/DCA; Q5001/
Modutrol IV Motor; MP953

Combustion Controls
VGF31EM30 3 in. DN80 115 Cv 99 kvs 175 psig at 1206 kPa at 125 58 psi 400 kPa ML6984/ML7984; ML6420/21A/25;
130 F (66 C) 66 C (130 F) ML7420/21A/25; Q5020/DCA; Q5001/

Residential
Modutrol IV Motor; MP953
VGF32EM30 3 in. DN80 115 Cv 99 kvs 400 psig 2758 kPA 250 58 psi 400 kPa ML6984/ML7984; ML6420/21A/25;
ML7420/21A/25; Q5020/DCA; Q5001/
Modutrol IV Motor; MP953
VGF31EM40 4 in. DN100 170 Cv 146 kvs 175 psig at 1206 kPa at 125 34 psi 234 kPa ML6421B; ML7421B; Q5001/Modutrol IV
130 F (66 C) 66 C (130 F) Motor; MP953
VGF32EM40 4 in. DN100 170 Cv 146 kvs 400 psig 2758 kPA 250 34 psi 234 kPa ML6421B; ML7421B; Q5001/Modutrol IV
Motor; MP953

Hydronic Controls
VGF31EM50 5 in. DN125 320 Cv 274 kvs 175 psig at 1206 kPa at 125 13 psi 90 kPa ML6421B; ML7421B; Q5001/Modutrol IV
130 F (66 C) 66 C (130 F) Motor; MP953
VGF32EM50 5 in. DN125 320 Cv 274 kvs 400 psig 2758 kPA 250 13 psi 90 kPa ML6421B; ML7421B; Q5001/Modutrol IV
Motor; MP953
VGF31EM60 6 in. DN150 370 Cv 317 kvs 175 psig at 1206 kPa at 125 13 psi 90 kPa ML6421B; ML7421B; Q5001/Modutrol IV
130 F (66 C) 66 C (130 F) Motor; MP953
VGF32EM60 6 in. DN150 370 Cv 317 kvs 400 psig 2758 kPA 250 13 psi 90 kPa ML6421B; ML7421B; Q5001/Modutrol IV
Motor; MP953
Valves with Linear (constant total) Flow Characteristic

Controls
Water
Valve Action: Diverting, stem down to close AB-A
Comments: Stem down to close AB-A

Maximum
Maximum Safe Close-off
Valve Size Flow Capacity Operating Pressure ANSI/ Pressure
ASME

Building Automation
Product Number (inch) DN (Cv) (Kv) (psi) (kPa) Rating (psi) (kPa) Used With
VGF31LD25 2 1/2 in. DN65 70 Cv 60 kvs 175 psig at 1206 kPa at 125 69 psi 475 kPa ML6984/ML7984; ML6420/21A/25;
130 F (66 C) 66 C (130 F) ML7420/21A/25; Q5020/DCA; Q5001/
Modutrol IV Motor; MP953
VGF32LD25 2 1/2 in. DN65 70 Cv 60 kvs 400 psig 2758 kPA 250 69 psi 475 kPa ML6984/ML7984; ML6420/21A/25;
ML7420/21A/25; Q5020/DCA; Q5001/
Modutrol IV Motor; MP953
VGF31LD30 3 in. DN80 120 Cv 103 kvs 175 psig at 1206 kPa at 125 34 psi 234 kPa ML6984/ML7984; ML6420/21A/25;
130 F (66 C) 66 C (130 F) ML7420/21A/25; Q5020/DCA; Q5001/
Modutrol IV Motor; MP953

Components
Commercial
VGF32LD30 3 in. DN80 120 Cv 103 kvs 400 psig 2758 kPA 250 34 psi 234 kPa ML6984/ML7984; ML6420/21A/25;
ML7420/21A/25; Q5020/DCA; Q5001/
Modutrol IV Motor; MP953
VGF31LD40 4 in. DN100 160 Cv 137 kvs 175 psig at 1206 kPa at 125 34 psi 234 kPa ML6421B; ML7421B; Q5001/Modutrol IV
130 F (66 C) 66 C (130 F) Motor; MP953
VGF32LD40 4 in. DN100 160 Cv 137 kvs 400 psig 2758 kPA 250 34 psi 234 kPa ML6421B; ML7421B; Q5001/Modutrol IV
Motor; MP953
Pneumatic Controls

VGF31LD50 5 in. DN125 285 Cv 244 kvs 175 psig at 1206 kPa at 125 13 psi 90 kPa ML6421B; ML7421B; Q5001/Modutrol IV
130 F (66 C) 66 C (130 F) Motor; MP953
VGF32LD50 5 in. DN125 285 Cv 244 kvs 400 psig 2758 kPA 250 13 psi 90 kPa ML6421B; ML7421B; Q5001/Modutrol IV
Motor; MP953
VGF31LD60 6 in. DN150 380 Cv 326 kvs 175 psig at 1206 kPa at 125 13 psi 90 kPa ML6421B; ML7421B; Q5001/Modutrol IV
130 F (66 C) 66 C (130 F) Motor; MP953
VGF32LD60 6 in. DN150 380 Cv 326 kvs 400 psig 2758 kPA 250 13 psi 90 kPa ML6421B; ML7421B; Q5001/Modutrol IV
Motor; MP953
Industrial Combustion
Controls

70-6910 647
Threaded Globe Valves
V5011F,G Two-Way Threaded Globe Valves
Used for two-position or modulating control of steam and water
and glycol solutions (to 50 percent concentration) in heating or
cooling systems.
• Sizes range from 2-1/2 to 3 inches.
• Direct acting
• High pressure steam models with stainless steel trim.
• Spring-loaded, self-adjusting packing.
• Stainless steel stem prevents corrosion.
• Valve designs provide equal percentage characteristics of flow for
close control of water, and linear characteristic of flow for close
control of steam or chilled water.
• Valves utilize direct mounting, electric or pneumatic linear valve
actuators; Q5001 linkage with Modutrol Motor; or Q5020/Q5022A
linkages with Direct Coupled Actuators to operate the valve.

Dimensions in inches (millimeters)


Valve Type: Globe Valve
Body Pattern: Two-way, Straight-through
Connection Type: Female NPT
Leakage Rating: 0.5% of Cv
Maximum Differential for Quiet Water Service: 20 psid (138 kPa)
3-1/2 Fluid Temperature Range: 40 F to 337 F (4 C to 169 C)
WITH Stem Travel: 3/4 in. (20 mm)
STEM
DOWN Bonnet Size: 1-3/8 in. (35 mm)
Valve Action: Stem down to close
ANSI/ASME Rating: 150
Actuation: Must be purchased separately
Materials
(Body): Red Brass
(Stem): Stainless Steel
(Seat): V5011F: Brass; V5011G: Stainless Steel
(Plug/Ball/Disc): V5011F: Teflon disc; V5011G: Stainless steel plug
with carbon-loaded Teflon disc
A (Packing): V5011F: Teflon and Nitrile; V5011G: Teflon Cone
Approvals:
CRN Number: 0C0861.9087YTN

C
V5011F,G
PIPE DIMENSIONS
BODY STYLE SIZE A B C
(in.) in mm in mm in mm
1/2 2 51 1-3/4 45 3-3/8 86
V5011F,G 3/4 1-3/4 45 1-3/4 45 3-3/8 86
THREADED 1 1-7/8 48 1-3/4 45 4-1/4 108
DIRECT 1-1/4 2 51 1-5/8 42 4-7/8 124
BODY
1-1/2 2-7/8 73 1-5/8 42 5-5/8 143
2 3-1/8 80 2 51 5-5/8 143
2-1/2 2-3/4 70 2-3/8 61 7-1/2 191
3 3-1/8 80 2-5/8 67 8-7/8 226
M2804A

648 customer.honeywell.com 70-6910


Threaded Globe Valves

Controls
Home
Maximum Safe Operating
Valve Size Flow Capacity Flow Pressure Materials
Charac- Controlled
Product Number (inch) DN (Cv) (Kv) teristic Fluid (psi) (kPa) Cartridge Used With
V5011F1105 2 1/2 in. DN65 63 Cv 54 kvs Equal Chilled or hot 217 psi at 250 F 1496 psi at — Q5001/Modutrol IV Motor;
Percentage water with up water; 121 C water; MP953; ML6420,21A,25;
to 50% Glycol. 250 psi at 100 F 1724 kPa at ML7420/ML7421A/
Not for use water 38 C water ML7425; ML6984/ML7984;

Indoor Air Quality


with steam or Q5020/DCA
fuels.
V5011G1111 2 1/2 in. DN65 63 Cv 54 kvs Linear Chilled or hot 240 psi water at 240 psi at 66 — ML6984/ML7984; Q5020/
water with up 150 F; C; 690 kPa at DCA; Q5001/Modutrol IV
to 50% Glycol. 100 psi at 337 F 69C steam Motor; MP953;
Not for use steam ML6420,21A,25; ML7420/
with fuels; ML7421A/ML7425
Steam

Combustion Controls
V5011F1113 3 in. DN80 100 Cv 85 kvs Equal Chilled or hot 217 psi at 250 F 1496 psi at Brass Q5020/DCA; ML6984/
Percentage water with up water; 121 C water; ML7984; ML7420/

Residential
to 50% Glycol. 250 psi at 100 F 1724 kPa at ML7421A/ML7425;
Not for use water 38 C water ML6420,21A,25; Q5001/
with steam or Modutrol IV Motor; MP953
fuels.
V5011G1129 3 in. DN80 100 Cv 85 kvs Linear Chilled or hot 240 psi water at 240 psi at 66 — ML7420/ML7421A/
water with up 150 F; C; 690 kPa at ML7425; ML6420,21A,25;
to 50% Glycol. 100 psi at 337 F 69C steam Q5001/Modutrol IV Motor;
Not for use steam MP953; Q5020/DCA;

Hydronic Controls
with fuels; ML6984/ML7984
Steam

Controls
Water
Building Automation
Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 649
Threaded Globe Valves
V5011N Two-way Globe Valves
Used for two-position or modulating control of steam and water
and glycol solutions (to 50 percent concentration) in heating or
cooling systems.
• Sizes range from 1/2 to 2 inches.
• Direct and reverse acting
• High pressure steam models with stainless steel trim
• Spring-loaded, self-adjusting packing.
• Stainless steel stem prevents corrosion.
• Valve designs provide equal percentage characteristics of flow for
close control of water, and linear characteristic of flow for close
control of steam or chilled water.
• Valves utilize direct mounting, electric or pneumatic linear valve
actuators; Q5001 linkage with Modutrol Motor; or Q5020/Q5022A
linkages with direct coupled rotary actuators to operate the valve.
• Not suitable for combustible gases.

Dimensions in inches (millimeters)


Valve Type: Globe Valve
Body Pattern: Two-way
Connection Type: Female NPT
Leakage Rating: Seat: 0.05% of Cv
Maximum Differential for Quiet Water Service: 20 psid (138 kPa)
Y1,2 Y1 Y2 Maximum Differential Pressure Ratings (Close-off): 240 psi (1655
kPa)
Ambient Temperature Range: 36 F to 248 F water (2 C to 120 C
water)
Stem Travel: 3/4 in. (20 mm)
B Bonnet Size: 1-3/8 in. (35 mm)
ANSI/ASME Rating: 150
Actuation: Must be purchased separately
Materials
(Body): Red Brass
(Stem): Stainless Steel
(Packing): Teflon
A
Approvals:
VALVE A B VALVE Y1 Y2a CRN Number: 0C0861.9087YTN/0C0861.99
SIZE (IN) in. (mm) in. (mm) in. (mm) in. (mm)
1/2 3-1/4 (83) 1-9/16 (40) V5011N1XXX 3-1/2 (89) 5-1/4 (133)
3/4 OR
1 4-1/16 (103) V5011N2XXX STEM FULLY DOWN
1-1/4 4-3/16 (106) V5011N3XXX 4-3/16 (107) 5-15/16 (151)
1-1/2 4-3/4 (120) 1-13/16 (47) STEM FULLY UP
2 5-1/4 (134)
a Y2 WITH STEM EXTENSION FOR MP953C,E (8 IN. ONLY) M17378A

Valves with Equal Percentage Flow Characteristic


Controlled Fluid: Chilled or hot water with up to 50% Glycol. Not for Materials
use with steam or fuels. Cartridge: Brass
Maximum Safe Operating Pressure: Plug/Ball/Disc: Brass
217 psi at 248 F (1500 kPa at 120 C)
Maximum Close-off Pressure: 240 psi (1655 kPa)

Valve Size Flow Capacity


Materials
Product Number (inch) DN (Cv) (Kv) (Seat) Valve Action Used With
V5011N1008 1/2 in. DN15 0.73 Cv 0.63 kvs Stainless Steel Stem down to close ML6984/ML7984; Q5020/DCA; Q5001/Modutrol IV Motor;
MP953; ML6420,21A,25; ML7420/ML7421A/ML7425
V5011N1016 1/2 in. DN15 1.2 Cv 1.0 kvs Stainless Steel Stem down to close Q5020/DCA; ML6984/ML7984; Q5001/Modutrol IV Motor;
MP953; ML7420/ML7421A/ML7425; ML6420,21A,25
V5011N1024 1/2 in. DN15 1.85 Cv 1.6 kvs Stainless Steel Stem down to close ML6984/ML7984; Q5020/DCA; Q5001/Modutrol IV Motor;
MP953; ML6420,21A,25; ML7420/ML7421A/ML7425
V5011N1032 1/2 in. DN15 2.9 Cv 2.5 kvs Stainless Steel Stem down to close Q5020/DCA; ML6984/ML7984; Q5001/Modutrol IV Motor;
MP953; ML7420/ML7421A/ML7425; ML6420,21A,25
V5011N3004 1/2 in. DN15 2.9 Cv 2.5 kvs Stainless Steel Stem up to close MP953; ML6984/ML7984; Q5020/DCA; Q5001/Modutrol IV
Motor; ML6420,21A,25; ML7420/ML7421A/ML7425
V5011N1040 1/2 in. DN15 4.7 Cv 4.0 kvs Stainless Steel Stem down to close ML6984/ML7984; Q5020/DCA; Q5001/Modutrol IV Motor;
MP953; ML6420,21A,25; ML7420/ML7421A/ML7425

650 customer.honeywell.com 70-6910


Threaded Globe Valves

Controls
Valve Size Flow Capacity

Home
Materials
Product Number (inch) DN (Cv) (Kv) (Seat) Valve Action Used With
V5011N3012 1/2 in. DN15 4.7 Cv 4.0 kvs Stainless Steel Stem up to close MP953; ML6984/ML7984; Q5020/DCA; Q5001/Modutrol IV
Motor; ML6420,21A,25; ML7420/ML7421A/ML7426
V5011N1057 3/4 in. DN20 7.3 Cv 6.3 kvs Stainless Steel Stem down to close Q5020/DCA; ML6984/ML7984; Q5001/Modutrol IV Motor;
MP953; ML7420/ML7421A/ML7425; ML6420,21A,25

Indoor Air Quality


V5011N3020 3/4 in. DN20 7.3 Cv 6.3 kvs Integral Brass Stem up to close MP953; ML6984/ML7984; Q5020/DCA; Q5001/Modutrol IV
Motor; ML6420,21A,25; ML7420/ML7421A/ML7427
V5011N1065 1 in. DN25 11.7 Cv 10 kvs Stainless Steel Stem down to close ML6984/ML7984; Q5020/DCA; Q5001/Modutrol IV Motor;
MP953; ML6420,21A,25; ML7420/ML7421A/ML7425
V5011N3038 1 in. DN25 11.7 Cv 10 kvs Integral Brass Stem up to close MP953; ML6984/ML7984; Q5020/DCA; Q5001/Modutrol IV
Motor; ML6420,21A,25; ML7420/ML7421A/ML7428
V5011N1073 1 1/4 in. DN32 18.7 Cv 16 kvs Stainless Steel Stem down to close Q5020/DCA; ML6984/ML7984; Q5001/Modutrol IV Motor;
MP953; ML7420/ML7421A/ML7425; ML6420,21A,25

Combustion Controls
V5011N3046 1 1/4 in. DN32 18.7 Cv 16 kvs Integral Brass Stem up to close MP953; ML6984/ML7984; Q5020/DCA; Q5001/Modutrol IV
Motor; ML6420,21A,25; ML7420/ML7421A/ML7429

Residential
V5011N1081 1 1/2 in. DN40 29 Cv 25 kvs Stainless Steel Stem down to close ML6984/ML7984; Q5020/DCA; Q5001/Modutrol IV Motor;
MP953; ML6420,21A,25; ML7420/ML7421A/ML7425
V5011N1099 2 in. DN50 46.8 Cv 40 kvs Stainless Steel Stem down to close Q5020/DCA; ML6984/ML7984; Q5001/Modutrol IV Motor;
MP953; ML7420/ML7421A/ML7425; ML6420,21A,25
Valves with Linear Flow Characteristic
Controlled Fluid: Steam; Chilled or hot water with up to 50% Glycol. Materials
Not for use with fuels Cartridge: Stainless Steel

Hydronic Controls
Maximum Safe Operating Pressure: Plug/Ball/Disc: Stainless Steel
100 psi/337 F steam (690 kPa/169C steam) Seat: Stainless Steel
Maximum Close-off Pressure: 240 psi (1655 kPa)

Valve Size Flow Capacity


Product Number (inch) DN (Cv) (Kv) Valve Action Used With
V5011N2006 1/2 in. DN15 0.73 Cv 0.63 kvs Stem down to close ML6984/ML7984; Q5020/DCA; Q5001/Modutrol IV Motor;
MP953; ML6420,21A,25; ML7420/ML7421A/ML7425
V5011N2014 1/2 in. DN15 1.2 Cv 1.0 kvs Stem down to close Q5020/DCA; ML6984/ML7984; Q5001/Modutrol IV Motor;

Controls
Water
MP953; ML7420/ML7421A/ML7425; ML6420,21A,25
V5011N2022 1/2 in. DN15 1.85 Cv 1.6 kvs Stem down to close ML6984/ML7984; Q5020/DCA; Q5001/Modutrol IV Motor;
MP953; ML6420,21A,25; ML7420/ML7421A/ML7425
V5011N2030 1/2 in. DN15 2.9 Cv 2.5 kvs Stem down to close Q5020/DCA; ML6984/ML7984; Q5001/Modutrol IV Motor;
MP953; ML7420/ML7421A/ML7425; ML6420,21A,25
V5011N2048 1/2 in. DN15 4.7 Cv 4.0 kvs Stem down to close ML6984/ML7984; Q5020/DCA; Q5001/Modutrol IV Motor;

Building Automation
MP953; ML6420,21A,25; ML7420/ML7421A/ML7425
V5011N2055 3/4 in. DN20 7.3 Cv 6.3 kvs Stem down to close Q5020/DCA; ML6984/ML7984; Q5001/Modutrol IV Motor;
MP953; ML7420/ML7421A/ML7425; ML6420,21A,25
V5011N2063 1 in. DN25 11.7 Cv 10 kvs Stem down to close ML6984/ML7984; Q5020/DCA; Q5001/Modutrol IV Motor;
MP953; ML6420,21A,25; ML7420/ML7421A/ML7425
V5011N2071 1 1/4 in. DN32 18.7 Cv 16 kvs Stem down to close Q5020/DCA; ML6984/ML7984; Q5001/Modutrol IV Motor;
MP953; ML7420/ML7421A/ML7425; ML6420,21A,25
V5011N2089 1 1/2 in. DN40 29 Cv 25 kvs Stem down to close ML6984/ML7984; Q5020/DCA; Q5001/Modutrol IV Motor;
MP953; ML6420,21A,25; ML7420/ML7421A/ML7425

Components
Commercial
V5011N2097 2 in. DN50 46.8 Cv 40 kvs Stem down to close Q5020/DCA; ML6984/ML7984; Q5001/Modutrol IV Motor;
MP953; ML7420/ML7421A/ML7425; ML6420,21A,25

Pneumatic Controls
Industrial Combustion
Controls

70-6910 651
Threaded Globe Valves
V5013N Three-Way Threaded Globe Valves
The V5013N is a three-way threaded globe valve that controls hot
water, cold water, and glycol solutions (up to 50 percent
concentration) in heating or cooling HVAC applications. The valves
are used for mixing service to direct flow from one or two inlets to
a common outlet in two-position or modulating control systems.
• Red brass body with NPT-threaded connections.
• Stainless steel stem and brass plug.
• Low seat leakage rating, < 0.05%.
• Spring-loaded, self adjusting packing.
• 50:1 rangeability per VDI/VDE 2173.
• Constant total flow throughout full stem travel.
• Accurate positioning to ensure state-of-the-art temperature control.
• Sizes range from 1/2 inch to 2 inches.
• Valves utilize direct mounting, electric or pneumatic valve actuators;
Q5001 linkage with Modutrol Motor; or Q5020/Q5022 linkages with
Direct Coupled Actuators to operate the valve.
• Repack and rebuild kits available for field servicing.
• Not suitable for combustible gases.

Dimensions in inches (millimeters)


Valve Type: Globe Valve
Body Pattern: Three-way mixing, A-B-AB porting
Flow Characteristic: Linear (B-AB), Equal Percentage (A-AB)
Connection Type: Female NPT
Controlled Fluid: Chilled or hot water with up to 50% Glycol. Not for
use with steam or fuels.
Y1,2 Y1 Y2
Leakage Rating: 0.05% of Cv
Maximum Safe Operating Pressure: 217 psi at 248 F (1500 kPa at
120 C)
Maximum Differential for Quiet Water Service: 20 psid (138 kPa)
Maximum Differential Pressure Ratings (Close-off): 240 psi (1655
kPa)
B Ambient Temperature Range: 36 F to 248 F water (2 C to 120 C
water)
Stem Travel: 3/4 in. (20 mm)
Bonnet Size: 1-3/8 in. (35 mm)
C NOTE: Y DIMENSION IS WITH
Valve Action: Mixing
STEM FULLY UP, NOT DOWN. ANSI/ASME Rating: 150
Actuation: Must be purchased separately
Materials
A
(Body): Red Brass
(Stem): Stainless Steel
VALVE A B C Y1 Y2a (Plug/Ball/Disc): Brass
SIZE STEM UP (Packing): Teflon/EPDM
1/2 (15) 3-1/4 (83) 1-9/16 (39.7) 2-9/16 (65) Approvals:
4-3/16 5-15/16
3/4 (20) 3-1/4 (83) 1-9/16 (39.7) 2-9/16 (65)
(106) (151) CRN Number: 0C0861.9087YTN/0C0861.123
1 (25) 4-1/16 (103) 1-9/16 (39.7) 2-5/8 (66.5)
1-1/4 (32) 4-3/16 (106) 1-9/16 (39.7) 2-7/8 (72.5)
1-1/2 (40) 4-3/4 (120) 1-13/16 (46.5) 3 (77)
2 (50) 5-1/4 (134) 1-13/16 (46.5) 3-5/16 (83.5)
a Y2 WITH STEM EXTENSION FOR MP953C,E (8 IN. ONLY) M12901A

Valve Size Flow Capacity Materials


Product Number (inch) DN (Cv) (Kv) (Seat) Used With
V5013N1030 1/2 in. DN15 2.9 Cv 2.5 kvs Stainless Steel ML6984/ML7984; Q5020/DCA; Q5001/Modutrol IV Motor; ML7420/ML7421A/
ML7425; ML6420,21A,25
V5013N1048 1/2 in. DN15 4.7 Cv 4.0 kvs Stainless Steel Q5020/DCA; ML6984/ML7984; Q5001/Modutrol IV Motor; ML6420,21A,25; ML7420/
ML7421A/ML7425
V5013N1055 3/4 in. DN20 7.3 Cv 6.3 kvs Integral Brass ML6984/ML7984; Q5020/DCA; Q5001/Modutrol IV Motor; ML7420/ML7421A/
ML7425; ML6420,21A,25
V5013N1063 1 in. DN25 11.7 Cv 10 kvs Integral Brass Q5020/DCA; ML6984/ML7984; Q5001/Modutrol IV Motor; ML6420,21A,25; ML7420/
ML7421A/ML7425
V5013N1071 1 1/4 in. DN32 18.7 Cv 16 kvs Brass ML6984/ML7984; Q5020/DCA; Q5001/Modutrol IV Motor; ML7420/ML7421A/
ML7425; ML6420,21A,25
V5013N1089 1 1/2 in. DN40 29 Cv 25 kvs Brass Q5020/DCA; ML6984/ML7984; Q5001/Modutrol IV Motor; ML6420,21A,25; ML7420/
ML7421A/ML7425
V5013N1097 2 in. DN50 46.8 Cv 40 kvs Brass ML6984/ML7984; Q5020/DCA; Q5001/Modutrol IV Motor; ML7420/ML7421A/
ML7425; ML6420,21A,25

652 customer.honeywell.com 70-6910


Globe Valve Accessories and Replacement Parts
Globe Valve Accessories

Controls
Home
Product Number Description Used With
209116 Stem Button for 4 inch to 6 inch V5011 and V3350 valves V3350; V5011
209117 Stem Button for 2 1/2 inch to 3 inch V5011 and V3350 valves V5011; V3350
304466 Set Screw —

Indoor Air Quality


311057 Lubricant, Tube —
311095A Stem and Disc holder, V5011A, C, F, Cv V5011A
311184 Guide-Cv 4.0 —
311745 Disc Holder —
311860 Plug, V5011A, F, 2 1/2 in., Cv 63 V5011A
313104 Disc, V5011, 1 in. NPT V5011

Combustion Controls
313719 Switch Assembly —

Residential
314539 Plug, V5011C, G, 3 in. NPT, Cv 100 V5011C
32003941-001 Seat Removal Tool —
32003941-002 Seat Removal Tool —

Globe Valve Replacement Parts

Hydronic Controls
Product Number Description Used With
311432 White Packing 3/8 inch I.D. V5011G1111; V5011G1129
311746 Disc holder for 3 in. valves V5011G1129; V5011F1113
14002734-001 Grease Tube —
14002734-002 Lubricant, packing, AMOCO H-100 —
311057 Lubricant, Tube —

VGF Packing Kits

Controls
Water
Product Number Description Used With
R43176754002 Packing kit for 2 1/2 in.and 3 in.ANSI 125 VGF valves VGF21, VGF31 up to 3"
R43176755004 Packing kit for 2 1/2 in.and 3 in.ANSI 250 and pressure-balanced VGF valves VGF21EP/LP; VGF22; VGF32; up to 3"

Building Automation
R43176755005 Packing kit for 4 in.to 6 in.VGF valves VGF2; VGF3; 4 to 6"

Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 653
Globe Valve Accessories and Replacement Parts
V5011; V5013 Valve Accessories and Replacement Parts
V5011 Replacement Seats V5011 Replacement Parts
Pipe Size Pipe Size
Part Number
Valve in. Cv (Old 150 psi) All Valve in. Part Number Description
V5011A,C,F,G 3/4 2.5 310536 — V5011H,J 1/2 to 1-1/4 310135 Spring for V5011H
6.3 — 310890 310137 Spacer (2) for V5011H
1 4.0 310537 — 310143 Packing V (3) for V5011H
6.3 310538 310498 Spring for V5011J
10 — 311077 310506 Follower V5011J
1-1/4 16 — 311078 310623 Packing Cone (3) V5011J
2 311291 — 313338 Stem
2-1/2 63 — 311731 V5011A,C,F,G 310509 Packing Nut; Old V5011
150 PSI series and
3 100 — 311734 V5011C,G
V5011 Replacement Plugs 1-1/2 to 3 14004552-001 Packing Nut, V5011A&C
Interim & V5011F,G
Pipe Size
1/2 to 3 14004623-001 Stem Button
Valve in. Cv Part Number
1-1/2 to 3 311619A Stem Assembly, 3/4 in.
V5011A,F 2-1/2 63 311860 Travel
3 100 311861
V5013 Replacement Parts
V5011C,G 3 100 314539
Pipe Size
V5011 Replacement Discs for Threaded Valves Valve in. Part Number Description
Pipe Size Part Number V5013A 2-1/2, 3 312495 Stem Button, Anti-Spin
(Flanged)
V5011A,F V5011C,G 4 to 6 312497 Packing Nut
Valve in. Cv (35 to 250 F) (200 to 337 F)
312498 Packing (5)
V5011A,C,F,G 1/2 0.4 to 4.0 14004625-001 —
2-1/2, 3 311432 Packing (4)
Threaded
3/4, 1 6.3, 10 — 14004625-012
1-1/4 16 14004625-003 14004625-013
1-1/2 25 14004625-004 14004625-014
2 40 14004625-005 14004625-015
2-1/2 63 14004625-006 14004625-016
3 100 14004625-007 14004625-017

654 customer.honeywell.com 70-6910


Globe Valve Accessories and Replacement Parts
V5011; V5013 Repack and Rebuild Kits

Controls
Home
V5011, V5013 Repack kits include packing, spacer, follower and
spring for V5011 and V5013 Valves. They are used to repack
leaking V5011 Valves with metal discs and all V5013 Three-Way CAUTION
Valves. They also can be used to repack V5011 Valves with rubber For proper installation, use instructions packed with kits.
or Teflon discs if the disc and stem assembly are known to be in V5011, V5013 Rebuild Kits include all the parts in the repack
good repair. Otherwise, use the appropriate rebuild kit for kits, plus a stem assembly and disc. Rebuild kits are available
only for threaded V5011 Valves. They cannot be used with

Indoor Air Quality


complete repair of V5011 Valves with rubber or Teflon discs and
valves that have a metal-to-metal seat. Metal-to-metal seats are
threaded ends. Repack kits are listed in the table below. found on V5011C and V5011G valves with OS numbers of
V5011C2282 or higher and V5011G1137 and higher.

NOTE: Rebuild kit Cv must match valve Cv. If the Cv is different, the
kit will not work, even if the pipe size shown is the same.
Some obsolete V5011A,C Valves were available with a
smaller Cv than listed below. When ordering a rebuild kit for
these valves, use Cv, not pipe size.

Combustion Controls
Residential
Valve Repack Kit Part Number Rebuild Kit Number
Stem Water and/or
Size Stroke Diameter 2-position Modulating for Water for Steam for Water for Steam
Connection (in.) Cv (in.) (in.) steam steam service service service service Comments
Threaded 1/2 0.4 3/4 1/4 — V5011C,G 14003294-004a 14003294-002 14002694-006 14002694-008 b, c

0.63 V5011A,F

Hydronic Controls
1
1.6
2.5
4
3/4 6.3 3/4 1/4 14002695-006 14002695-008
1 10
1-1/4 16 3/4 1/4 14003109-006 14003109-008
Threaded 1-1/2 25 3/4 3/8 V5011A,F V5011C,G 14003295-004 14003295-002 14003110-006 14003110-008 b, c

Controls
2 40 14003111-006 14003111-008 a b, c, d

Water
2-1/2 63
3 100
Threaded 1/2 2.5 3/4 1/4 V5011H V5011J 14003294-004a 14003294-002 not available not available b, e

4
3/4 6.3

Building Automation
1 10
1-1/4 16
Threaded 1/2 2.5 3/4 1/4 V5013A,F — 14003294-004a — not available —
4
3/4 6.3
1 10
1-1/4 16
Threaded 1-1/2 25 3/4 3/8 V5013A,F — 14003295-004 — not available —

Components
Commercial
2 40
Flange 2-1/2 63 3/4 3/8 V5011A1734 — 14003295-004 14003295-002 not available not available b

3 100 3/4 3/8 V5011A1767


Flange 4 160 1-1/2 1/2 V5011A,B — 14003296-002 14003296-002 not available not available b, f

5 250
6 360
Pneumatic Controls

a TRADELINE Kit.
b
The 1400xxxx-002, -004 Repack and -006, -008 Rebuild Kits contain the same parts as the -001, -003 Repack and -005, and -007 Rebuild Kits
available from Honeywell Direct.
c
V5011G1137 through V5011G1228 Valves have metal-to-metal seats; rebuild kits are not available for metal-to-metal seat valves.
d To rebuild a 2-1/2 or 3 in. threaded valve, order the rebuild kit for the 2 in. valve and the replacement disc for the 2-1/2 or 3 in. valve. See Valve
Accessories and Replacement Parts section.
e
Rebuild kits are not available for reverse acting valves.
Industrial Combustion

f Repack kits with Teflon packing rings (14003296-002) are used with 4 through 6 in. valves (both water and steam service).
Kits with rubber packing are not available for 4 through 6 in. valves.
Controls

70-6910 655
Globe Valve Accessories and Replacement Parts
Valve Repack Kit Part Number Rebuild Kit Number
Stem Water and/or
Size Stroke Diameter 2-position Modulating for Water for Steam for Water for Steam
Connection (in.) Cv (in.) (in.) steam steam service service service service Comments
Flange 2-1/2 63 3/4 3/8 V5013B,C — 14003295-004 — not available — b, f

3 100
Flange 4 160 1-1/2 1/2 V5013B,C — 14003296-002
5 250
6 360
a
TRADELINE Kit.
b
The 1400xxxx-002, -004 Repack and -006, -008 Rebuild Kits contain the same parts as the -001, -003 Repack and -005, and -007 Rebuild Kits
available from Honeywell Direct.
c V5011G1137 through V5011G1228 Valves have metal-to-metal seats; rebuild kits are not available for metal-to-metal seat valves.
d
To rebuild a 2-1/2 or 3 in. threaded valve, order the rebuild kit for the 2 in. valve and the replacement disc for the 2-1/2 or 3 in. valve. See Valve
Accessories and Replacement Parts section.
e
Rebuild kits are not available for reverse acting valves.
f
Repack kits with Teflon packing rings (14003296-002) are used with 4 through 6 in. valves (both water and steam service).
Kits with rubber packing are not available for 4 through 6 in. valves.

14003294-002 1/2 to 1-1/4 in. valve size, for steam service. 14003294-004 1/2 to 1-1/4 in. valve size, for water service.

BUTTON BUTTON

PACKING NUT PACKING NUT


OR GLAND OR GLAND

RUBBER "V"
TEFLON CONE RING PACKING *
PACKING *
SPACER *
FOLLOWER *

FOLLOWER
SPRING * FOLLOWER
SPRING *

BONNET
BONNET

STEM AND DISC


HOLDER ASSEMBLY STEM AND DISC
HOLDER ASSEMBLY

PACKING
LUBRICANT * PACKING
LUBRICANT *
M8289A
* INCLUDED IN KIT. M8290A
* INCLUDED IN KIT.

656 customer.honeywell.com 70-6910


Globe Valve Accessories and Replacement Parts
14003295-004 1-1/2 to 3 in. valve size, for water service. 14003295-002 1-1/2 to 3 in. valve size, for steam service.

Controls
Home
BUTTON
BUTTON

PACKING NUT
OR GLAND PACKING NUT
OR GLAND

Indoor Air Quality


FEMALE ADAPTER *
PACKING *
PACKING (WHITE) *

PACKING (BLACK) *

PACKING (WHITE) *
FOLLOWER *
MALE ADAPTER *
FOLLOWER
SPRING *

Combustion Controls
FOLLOWER
SPRING *

Residential
RETAINER *

O RING *
BONNET

BONNET

Hydronic Controls
STEM AND DISC STEM AND DISC
HOLDER ASSEMBLY HOLDER ASSEMBLY

PACKING
PACKING LUBRICANT *
LUBRICANT *
FLANGED SCREWED

Controls
* INCLUDED IN KIT. M4902 * INCLUDED IN KIT.
VALVES VALVES

Water
M4903A
14003296-002 4 to 6 in. pipe size, for steam service.

BUTTON

PACKING NUT

Building Automation
OR GLAND

PACKING *

FOLLOWER *

FOLLOWER
SPRING *

Components
Commercial
BONNET

Pneumatic Controls

STEM

PACKING
LUBRICANT *
Industrial Combustion

FLANGED
VALVES * INCLUDED IN KIT.
M13115
Controls

70-6910 657
Globe Valve Accessories and Replacement Parts
Rebuild Kits for: 14002694-006, 14002695-006, 14003109-006, 1/2 to Rebuild Kits for: 14003110-006, 140031111-006, 1-1/2 to 3 in. valve
1-1/4 in. valve size for water service; 14002694-008, 14002695-008, size for water service; 14003110-008, 14003111-008, 1-1/2 to 3 in.
14003109-008, 1/2 to 1-1/4 in. valve size for steam service. valve size for steam service.
BUTTON
BUTTON

PACKING
PACKING GLAND
GLAND 2
1
1 2
PACKING *
PACKING *

FOLLOWER *
FOLLOWER *
FOLLOWER
SPRING *
FOLLOWER
SPRING *

BONNET

BONNET
STEM RETAINER
NUT

STEM
STEM AND DISC ASSEMBLY *
HOLDER ASSEMBLY *

STEM RETAINER
SPRINGS *
DISC *

DISC SPRING DISC HOLDER

PLUG
DISC *

SEAT DISC SPRING

PLUG
PLUG NUT

SEAT
PACKING
LUBRICANT *

* INCLUDED IN KIT. PACKING


LUBRICANT *
1 PACKING FOR WATER SERVICE. * INCLUDED IN KIT.
2 PACKING FOR STEAM SERVICE.
M13083 1 PACKING FOR WATER SERVICE.

2 PACKING FOR STEAM SERVICE.


M13085

658 customer.honeywell.com 70-6910


Globe Valve Accessories and Replacement Parts
V5011N Valve Rebuild and Repack Kits .

Controls
Home
V5011N DIRECT ACTING V5011N REVERSE ACTING Stem
TWO-WAY GLOBE VALVES TWO-WAY GLOBE VALVES Diameter Stem
STEM BUTTON ASSEMBLY 2
Valve OS No. (in.) Repack Kit Rebuild Kit Button
STEM BUTTON ASSEMBLY 2
PACKING NUT V5011N1008 1/4 0901786A 0901746A 0901116Aa
PACKING NUT
1 2
1 2
V5011N1016 0901747A
PACKING WAFERS PACKING WAFERS

V5011N1024 0901748A

Indoor Air Quality


WASHER 1 2 WASHER 1 2

SPRING 1 2 SPRING 1
V5011N1032 0901749A
2
V5011N1040 0901750A
PACKING CARTRIDGE 2 PACKING CARTRIDGE 2
V5011N1057 0901751A
1 2
V5011N1065 0901752A
O RING 1 2 O RING

VALVE BODY
VALVE BODY V5011N1073 0901753A

Combustion Controls
V5011N1081 3/8 0901787A 0901754A
AB V5011N1099 0901755A

Residential
A A
B B
SEAT RING 2
V5011N2022 1/4 0901786A 0903424A
PLUG ASSEMBLY 2 V5011N2030 0903425A
PLUG ASSEMBLY 2 V5011N2048 0903426A
V5011N2055 0903427A
SEAT RING 2 V5011N2063 0903428A

Hydronic Controls
O RING 2 O RING 2
V5011N2071 0903429A
V5011N2089 3/8 0901787A 0903430A
BOTTOM NUT LOWER SEAT
V5011N2097 0903431A
V5011N3004 1/4 0901786A 0901759A
BOTTOM NUT 3
1 PART INCLUDED IN REPACK KIT. 0901787A REPACK KIT V5011N3012 0901760A
(FOR VALVES WITH 3/8 INCH STEM) SHOWN. 0901786A
REPACK KIT (FOR VALVES WITH 1/4 INCH STEM)
CONTAINS THREE PACKING WAFERS INSTEAD OF FOUR. V5011N3020 0901761A
2 INCLUDED IN REBUILD KIT. V5011N3038 0901762A
3 INCLUDED ONLY WITH V5011N REVERSE ACTING TWO-WAY GLOBE VALVES. M12872A
V5011N3046 0901763A

Controls
Water
aEach 0901116A contains 10 stem buttons.
Note: Seat removal tools are required to rebuild valves:
32003941-001 for 1/2 in. through 1-1/4 in. sizes.
32003941-002 for 1-1/2 in. through 2 in. sizes.

Building Automation
Components
Commercial
Pneumatic Controls
Industrial Combustion
Controls

70-6910 659
Globe Valve Accessories and Replacement Parts
V5013N Three-way Globe Valves V5013N Replacement Parts
V5013N THREE-WAY GLOBE VALVES Stem Stem
Diameter Repack Kit Rebuild Kit Button
Valve OS No. (in.) (Part No.) (Part No.) (Part No.)
STEM BUTTON ASSEMBLY 2 V5013N1030 1/4 0901786A 0901759A 0901116Aa
PACKING NUT V5013N1048 0901760A
V5013N1055 0901761A
PACKING WAFERS 1 2 V5013N1063 0901762A
V5013N1071 0901763A
WASHER 1 2
V5013N1089 3/8 0901787A 0901764A
SPRING 1 2 V5013N1097 0901765A
a
Each 0901116A contains 10 stem buttons.
PACKING CARTRIDGE 2
NOTE:32003941-001 Seat Removal Tool required to rebuild 1/2 in.
O RING 1 2 valves. Other sizes do not require this tool.

VALVE BODY

A AB
B
SEAT RING 2

PLUG ASSEMBLY 2

O RING 2

LOWER SEAT

1 PART INCLUDED IN REPACK KIT. 0901787A REPACK KIT


(FOR VALVES WITH 3/8 INCH STEM) SHOWN. 0901786A
REPACK KIT (FOR VALVES WITH 1/4 INCH STEM)
CONTAINS THREE PACKING WAFERS INSTEAD OF FOUR.

2 INCLUDED IN REBUILD KIT. M12871A

660 customer.honeywell.com 70-6910


Double-Seated Globe Valves
V5047A Double-Seated Globe Valves

Controls
Home
Control high pressure steam, liquids, air or noncombustible gases
where positive final shutoff is not required.
• Q5001D Valve Linkage and Modutrol motor required for operation.
• Suitable for two-position, floating, or proportioning control,
depending on the motor and controller used.
• Provide high capacity with minimum pressure drop.
• Pipe sizes include 1, 1-1/4, 1-1/2, and 2 inches.

Indoor Air Quality


• Straight-through construction and threaded end connections.
• Cast iron body with stainless steel trim.
• Plug provides equal percentage characteristic of flow.
• V-port for either throttling or on-off service.
• Replaceable seat rings screw into body.
• Spring-loaded Teflon cone packing for minimum friction.

Combustion Controls
Residential
Dimensions in inches (millimeters)
Valve Type: Globe Valve
Body Pattern: Two-way
4-1/8 (105) MINIMUM
Valve Action: Stem down to close
CLEARANCE TO Connection Type: Female NPT
REMOVE ACTUATOR Flow Characteristic: Equal Percentage
FROM VALVE Controlled Fluid: Steam; Chilled or hot water with up to 50% Glycol.
5-5/8 (143) MAX. Not for use with fuels

Hydronic Controls
Leakage Rating: 0.005 of Cv
Maximum Safe Operating Pressure: 100 psi steam (690 kPa steam);
150 psi water (1034 kPa)
Ambient Temperature Range: 32 F to 337 F (0 C to 170 C)
ACTUATOR Bonnet Size: 1-3/8 in. (35 mm)
ANSI/ASME Rating: 125
Actuation: Must be purchased separately
Comments: Double seated
B
Materials
(Body): Cast Iron
(Stem): Stainless Steel

Controls
Water
(Seat): Stainless Steel
(Packing): Spring loaded non-adjustable Teflon V-ring

Building Automation
C

DIMENSIONS IN INCHES (MM)


VALVE SIZE A B C
1 4-3/8 (111) 17 (432) 2-3/8 (60)
1-1/4 4-5/8 (117) 17-3/16 (437) 2-9/16 (65)
1-1/2 5-1/2 (140) 17-1/2 (445) 3-1/8 (79)

Components
Commercial
2 6-1/2 (165) 17-3/4 (451) 3-3/8 (86)
M27555

Valve Size Flow Capacity Materials Stem Travel


Product Number (inch) DN (Cv) (Kv) (Cartridge) (inch) (mm) Comments Used With
V5047A1021 1 1/2 in. DN40 30 Cv 25.7 kvs Stainless Steel 9/16 in. 14 mm Double seated Q5001/Modutrol IV Motor
Pneumatic Controls

V5047A1039 2 in. DN50 50 Cv 43 kvs — 3/4 in. 20 mm Double seated Q5001/Modutrol IV Motor
Industrial Combustion
Controls

70-6910 661
Cage Valves
V5051A Single-Seated Cage Valves
Single-Seated Cage Valves control steam, air, liquids, or non-
combustible gases in two-position, proportional, or floating
control systems where line isolation is not required.
• Pressure balanced cage type construction.
• Low operating force allows fail safe operation with spring return
actuator.
• Combines 1 3/8 in. bonnet with 1 1/2 in. stroke.
• Sizes range from 2-1/2 to 6 in. (DN65 to DN150).
• Spring-loaded Teflon V-ring packing.
• Requires Q5020C valve linkage with one rotary, direct coupled
actuator, or Q5001D with Modutrol Motor.

Dimensions in inches (millimeters)


Valve Type: Cage Valves
CLEARANCE Body Pattern: Two-way, Straight-through
TO REMOVE Connection Type: Flanged
4 (102) MINIMUM
ACTUATOR Flow Characteristic: Modified Linear
FROM VALVE
Controlled Fluid: Steam; Chilled or hot water with up to 50% Glycol.
Not for use with fuels
Leakage Rating: 0.01% of Cv, 0.03% of Cv @ 5 & 6 in.
VALVE A B C Maximum Safe Operating Pressure: 55 psi steam (379 kPa steam);
VALVE SIZE IN. MM IN. MM IN. MM 150 psi water at 100F (1034 kPa water at 38 C)
LINKAGE
2-1/2 9-1/2 241 3-1/2 89 4-5/8 117 Maximum Differential Pressure Ratings (Close-off): 150 psi (1034
15-1/16 3 11 297 3-15/16 100 4-7/8 124 kPa)
(382) 4 13 330 4-1/2 114 5-5/8 143 Ambient Temperature Range: 35 F to 300 F (2 C to 150 C)
5 15 381 5-1/2 140 7-3/8 187
Stem Travel: 1 1/2 in. (38 mm)
6 16-1/2 419 6-3/8 162 7-3/8 187
Bonnet Size: 1-3/8 in. (35 mm)
Valve Action: Stem down to close
ANSI/ASME Rating: 125
Actuation: Must be purchased separately
Comments: Q5001D1000 requires 1/2 in. 220867A Cam.
Materials
C
(Body): Cast Iron
(Stem): Stainless Steel
(Seat): Resilient
(Plug/Ball/Disc): Stainless Steel
B (Packing): Teflon

A M27552

Valve Size Flow Capacity


Product Number (inch) DN (Cv) (Kv) Used With
V5051A3004 2 1/2 in. DN65 75 Cv 64.5 kvs MP953 8 in., Q5001D/Modutrol IV Motor, or Q5020C/DCA
V5051A3012 3 in. DN80 116 Cv 88 kvs MP953 8 in., Q5001D/Modutrol IV Motor, or Q5020C/DCA
V5051A3020 4 in. DN100 178 Cv 125 kvs MP953 8 in., Q5001D/Modutrol IV Motor, or Q5020C/DCA
V5051A3038 5 in. DN125 318 Cv 224 kvs MP953 8 in., Q5001D/Modutrol IV Motor, or Q5020C/DCA
V5051A3046 6 in. DN150 390 Cv 224 kvs MP953 8 in., Q5001D/Modutrol IV Motor, or Q5020C/DCA

662 customer.honeywell.com 70-6910


Cartridge Globe Valves
V5852; V5862 Two-way Cartridge Globe Valves

Controls
Home
Two-way Cartridge Globe Valves control hot and/or chilled water
for VAV terminal units, fan coil units, small reheaters and recoolers
in electric/electronic temperature control systems. Used with the
M6410 3-position floating Non-Spring Return Valve Actuator and
the M7410 selectable 0 to 10 Vdc or 2 to 10 Vdc Non-Spring Return
Actuator. The 1/2 in. and 3/4 in. valves are compatible with the
M6435 floating Spring Return Actuator, the M7435 selectable 0 to

Indoor Air Quality


10 Vdc or 2 to 10 Vdc Spring Return Actuator, and the MP958
Pneumatic Actuator. Larger valves (1 in. through 1-1/2 in.) are
pressure balanced, which results in higher close-off pressures.
• Long stroke allows wider range of control.
• Soft valve seat provides low leakage rate.
• Inserts for 1/2 in. and 3/4 in. valves are changeable without draining
valve when used with an insert replacement tool.
• Brass body and Stainless Steel stem.
• Threaded plastic cover/manual handle allows manual operation.

Combustion Controls
• Easily installed in areas where space is limited.

Residential
Hydronic Controls
Dimensions in inches (millimeters)

MINIMUM CLEARANCE
STROKE 1/4 (6.5) 23/32 9-7/8
(18) (250) G

Controls
Water
C A
C
D

F
B
VALVE SIZE

Building Automation
A (NPT) B C D E F G

1 (25) 4-1/8 (105) 1-5/8 (41) 2-1/16 (53) 3-5/8 (92) 2 (50) 1-3/4 (44)
For 1/2 in. and 3/4 in. Valves 1-1/4 (32) 4-15/16 (125) 2 (50) 2-7/16 (62) 3-5/8 (92) 2-3/16 (55) 2-1/4 (57)
1-1/2 (38) 5-1/8 (130) 2-3/16 (55) 2-9/16 (65) 3-7/8 (98) 2-3/8 (60) 2-5/8 (67)

V5862 FLOW V5863 FLOW

OUTLET PORT AB
INLET PORT A

Components
Commercial
PORT B M19619

Pneumatic Controls
Industrial Combustion
Controls

70-6910 663
Cartridge Globe Valves
Valve Type: Cartridge Globe Valve Accessories:
Body Pattern: Two-way 0902807 Replacement Insert for 1/2 in. V5852/V5862, 1.9Cv
Controlled Fluid: Chilled or hot water with up to 50% Glycol. Not for Interchangeable with 0902808
use with steam or fuels. 0902808 Replacement Insert for 1/2 in. V5852/V5862, 1.2 Cv
Leakage Rating: Interchangeable with 0902807
1/2 in. and 3/4 in. valves: ANSI Class IV (0.01% of Cv maximum) 0902809 Replacement Insert for 1/2 in. V5852/V5862, 0.74 Cv
1 in, 1-1/4 in, 1-1/2 in valves: ANSI Class III (less than 0.02% of Cv) Interchangeable with 0902810 or 090212
Maximum Safe Operating Pressure: 235 psi (1620 kPA) 0902810 Replacement Insert for 1/2 in. V5852/V5862, 0.47 Cv
Ambient Temperature Range: 36 F to 230 F (2 C to 110 C) Interchangeable with 0902809 or 090212
Stem Travel: 1/4 in. (6.4 mm)
Actuation: Must be purchased separately Replacement Parts:
0902812 Replacement Insert for 1/2 in. V5852/V5862, 0.19 Cv
Materials
Interchangeable with 0902809 or 090210
(Body): Brass
0902814 Replacement Insert for 3/4 in. V5852/V5862, 2.9 Cv
(Stem): Stainless Steel
Interchangeable with 0902815
(Seat): Brass
0902815 Replacement Insert for 3/4 in. V5852/V5862, 4.9 Cv
(Cartridge): Brass
Interchangeable with 0902814
(Plug/Ball/Disc): Brass
0903827 Replacement Packing for 1 in. V5862/63
0903828 Replacement Packing for 1-1/4 in. V5862/63
0903829 Replacement Packing for 1-1/2 in. V5862/63

Maximum Close-
Valve Size Flow Capacity off Pressure
Flow Connec- Valve
Product Number (inch) DN (Cv) (Kv) Characteristic tion Type Action (psi) (kPa) Used With
V5852A2007 1/2 in. DN15 0.19 Cv 0.16 kvs Equal Sweat Stem down 232 psi 1600 kPa M6410A1029; M7410F1000;
Percentage (Female) to close M6435A1004; M7435F1001; MP958
V5852A2015 1/2 in. DN15 0.29 Cv 0.25 kvs Equal Sweat Stem down 232 psi 1600 kPa M6410A1029; M6435A1004;
Percentage (Female) to close M7410F1000; M7435F1001; MP958
V5852A2023 1/2 in. DN15 0.47 Cv 0.41 kvs Equal Sweat Stem down 232 psi 1600 kPa M6410A1029; M7410F1000;
Percentage (Female) to close M6435A1004; M7435F1001; MP958
V5852A2031 1/2 in. DN15 0.7 Cv 0.6 kvs Equal Sweat Stem down 232 psi 1600 kPa M6410A1029; M6435A1004;
Percentage (Female) to close M7410F1000; M7435F1001; MP958
V5852A2049 1/2 in. DN15 1.2 Cv 1.0 kvs Equal Sweat Stem down 174 psi 1200 kPa M6410A1029; M7410F1000;
Percentage (Female) to close M6435A1004; M7435F1001; MP958
V5852A2056 1/2 in. DN15 1.9 Cv 1.6 kvs Equal Sweat Stem down 174 psi 1200 kPa M6410A1029; M6435A1004;
Percentage (Female) to close M7410F1000; M7435F1001; MP958
V5852A2064 3/4 in. DN20 2.9 Cv 2.5 kvs Equal Sweat Stem down 58 psi 400 kPa M6410A1029; M7410F1000;
Percentage (Female) to close M6435A1004; M7435F1001; MP958
V5852A2072 3/4 in. DN20 4.9 Cv 4.2 kvs Equal Sweat Stem down 58 psi 400 kPa M6410A1029; M6435A1004;
Percentage (Female) to close M7410F1000; M7435F1001; MP958
V5862A2005 1/2 in. DN15 0.19 Cv 0.16 kvs Equal Female Stem down 232 psi 1600 kPa M6410A1029; M6435A1004;
Percentage NPT to close M7410F1000; M7435F1001; MP958
V5862A2013 1/2 in. DN15 0.29 Cv 0.25 kvs Equal Female Stem down 232 psi 1600 kPa M6410A1029; M7410F1000;
Percentage NPT to close M6435A1004; M7435F1001; MP958
V5862A2021 1/2 in. DN15 0.47 Cv 0.41 kvs Equal Female Stem down 232 psi 1600 kPa M6410A1029; M6435A1004;
Percentage NPT to close M7410F1000; M7435F1001; MP958
V5862A2039 1/2 in. DN15 0.74 Cv 0.64 kvs Equal Female Stem down 232 psi 1600 kPa M6410A1029; M7410F1000;
Percentage NPT to close M6435A1004; M7435F1001; MP958
V5862A2047 1/2 in. DN15 1.2 Cv 1.0 kvs Equal Female Stem down 174 psi 1200 kPa M6410A1029; M6435A1004;
Percentage NPT to close M7410F1000; M7435F1001; MP958
V5862A2054 1/2 in. DN15 1.9 Cv 1.6 kvs Equal Female Stem down 174 psi 1200 kPa M6410A1029; M7410F1000;
Percentage NPT to close M6435A1004; M7435F1001; MP958
V5862A2062 3/4 in. DN20 2.9 Cv 2.5 kvs Equal Female Stem down 58 psi 400 kPa M6410A1029; M6435A1004;
Percentage NPT to close M7410F1000; M7435F1001; MP958
V5862A2070 3/4 in. DN20 4.9 Cv 4.2 kvs Equal Female Stem down 58 psi 400 kPa M6410A1029; M7410F1000;
Percentage NPT to close M6435A1004; M7435F1001; MP958
V5862A3003 1 in. DN25 5.5 Cv 4.8 kvs Linear Female Stem up to 232 psi 1600 kPa M6410A3017; M7410F3006;
NPT close M6435A3000; M7435F3007
V5862A3011 1 in. DN25 7.8 Cv 6.7 kvs Linear Female Stem up to 232 psi 1600 kPa M6410A3017; M7410F3006;
NPT close M6435A3000; M7435F3007
V5862A3029 1 in. DN25 11.0 Cv 9.5 kvs Linear Female Stem up to 232 psi 1600 kPa M6410A3017; M7410F3006;
NPT close M6435A3000; M7435F3007
V5862A3037 1 1/4 in. DN32 18 Cv 15.6 kvs Linear Female Stem up to 174 psi 1200 kPa M6410A3017; M7410F3006;
NPT close M6435A3000; M7435F3007
V5862A3045 1 1/2 in. DN40 25 Cv 21.6 kvs Linear Female Stem up to 145 psi 1000 kPa M6410A3017; M7410F3006;
NPT close M6435A3000; M7435F3007

664 customer.honeywell.com 70-6910


Cartridge Globe Valves
V5853; V5863 Three-way Cartridge Globe Valves

Controls
Home
Three-way Cartridge Globe Valves control hot and/or chilled water
for VAV terminal units, fan coil units, small reheaters and recoolers
in electric/ electronic temperature control systems. Used with the
M6410 3-position floating Non-Spring Return Valve Actuator and
the M7410 selectable 0 to 10 Vdc or 2 to 10 Vdc Non-Spring Return
Actuator. The 1/2 in. and 3/4 in. valves are also compatible with the
M6435 floating Spring Return Actuator, the M7435 selectable 0 to

Indoor Air Quality


10 Vdc or 2 to 10 Vdc Spring Return Actuator, and the MP958
Pneumatic Actuator.
• Long stroke allows wider range of control.
• Soft valve seat provides low leakage rate.
• Inserts for 1/2 in. and 3/4 in. valves are changeable without draining
valve when used with an insert replacement tool.
• Brass body and stainless steel stem.
• Threaded plastic cover/manual handle allows manual operation.
• Easily installed in areas where space is limited.

Combustion Controls
Residential
Hydronic Controls
Dimensions in inches (millimeters)

MINIMUM CLEARANCE
STROKE 1/4 (6.5) 23/32 9-7/8
(18) (250) G

Controls
Water
E

C A
C
D

Building Automation
B
VALVE SIZE
A (NPT) B C D E F G

1 (25) 4-1/8 (105) 1-5/8 (41) 2-1/16 (53) 3-5/8 (92) 2 (50) 1-3/4 (44)
1-1/4 (32) 4-15/16 (125) 2 (50) 2-7/16 (62) 3-5/8 (92) 2-3/16 (55) 2-1/4 (57)
1-1/2 (38) 5-1/8 (130) 2-3/16 (55) 2-9/16 (65) 3-7/8 (98) 2-3/8 (60) 2-5/8 (67)

V5862 FLOW V5863 FLOW

Components
OUTLET PORT AB

Commercial
INLET PORT A

PORT B M19619

Pneumatic Controls
Industrial Combustion
Controls

70-6910 665
Cartridge Globe Valves
Valve Type: Cartridge Globe Valve Accessories:
Body Pattern: Three-way 0903827 Replacement Packing for 1 in. V5862/63
Controlled Fluid: Chilled or hot water with up to 50% Glycol. Not for
use with steam or fuels. Replacement Parts:
Leakage Rating: 0902821 Replacement Insert for 1/2 in. V5853/V5863, 0.29 Cv
1/2 in. and 3/4 in. valves: ANSI Class IV (0.01% of Cv maximum) Interchangeable with 0902822 or 0902823 or 0902824
1 in, 1-1/4 in, 1-1/2 in valves: ANSI Class III (less than 0.02% of Cv) 0902822 Replacement Insert for 1/2 in. V5853/V5863, 0.47 Cv
Maximum Safe Operating Pressure: 235 psi (1620 kPA) Interchangeable with 0902821 or 0902823 or 0902824
Maximum Differential Pressure Ratings (Close-off): 34 psi (234 kPa) 0902823 Replacement Insert for 1/2 in. V5853/V5863, 0.74 Cv
Ambient Temperature Range: 36 F to 230 F (2 C to 110 C) Interchangeable with 0902821 or 0902822 or 0902824
Stem Travel: 1/4 in. (6.4 mm) 0902824 Replacement Insert for 1/2 in. V5853/V5863, 1.2 Cv
Actuation: Must be purchased separately Interchangeable with 0902821 or 0902822 or 0902823
Materials 0902825 Replacement Insert for 1/2 in. V5853/V5863, 1.9 Cv
(Body): Brass Interchangeable with 0902827
(Stem): Stainless Steel 0902827 Replacement Insert for 3/4 in. V5853/V5863, 4.9 Cv
(Seat): Brass Interchangeable with 0902825
(Cartridge): Brass 0903827 Replacement Packing for 1 in. V5862/63
(Plug/Ball/Disc): Brass 0903828 Replacement Packing for 1-1/4 in. V5862/63
0903829 Replacement Packing for 1-1/2 in. V5862/63

Maximum Close-
Valve Size Flow Capacity off Pressure
Flow Connec- Valve
Product Number (inch) DN (Cv) (Kv) Characteristic tion Type Action (psi) (kPa) Used With
V5853A1008 3/4 in. DN20 2.9 Cv 2.5 kvs Equal Sweat Stem up to 34 psi 234 kPa M6410A1029; M7410F1000;
Percentage (Female) close M6435A1004; M7435F1001
V5853A1016 3/4 in. DN20 4.9 Cv 4.2 kvs Equal Sweat Stem up to 34 psi 234 kPa M6410A1029; M6435A1004;
Percentage (Female) close M7410F1000; M7435F1001
V5853A2006 1/2 in. DN15 0.29 Cv 0.25 kvs Equal Sweat Stem up to 116 psi 800 kPa M6410A1029; M7410F1000;
Percentage (Female) close M6435A1004; M7435F1001; MP958
V5853A2014 1/2 in. DN15 0.47 Cv 0.41 kvs Equal Sweat Stem up to 116 psi 800 kPa M6410A1029; M6435A1004;
Percentage (Female) close M7410F1000; M7435F1001; MP958
V5853A2022 1/2 in. DN15 0.74 Cv 0.64 kvs Equal Sweat Stem up to 36 psi 248 kPa M6410A1029; M7410F1000;
Percentage (Female) close M6435A1004; M7435F1001; MP958
V5853A2030 1/2 in. DN15 1.2 Cv 1.0 kvs Equal Sweat Stem up to 36 psi 248 kPa M6410A1029; M6435A1004;
Percentage (Female) close M7410F1000; M7435F1001; MP958
V5853A2048 1/2 in. DN15 1.9 Cv 1.6 kvs Equal Sweat Stem up to 34 psi 234 kPa M6410A1029; M7410F1000;
Percentage (Female) close M6435A1004; M7435F1001; MP958
V5853A2055 3/4 in. DN20 2.9 Cv 2.5 kvs Equal Sweat Stem up to 7.25 psi 50 kPa M6410A1029; M6435A1004;
Percentage (Female) close M7410F1000; M7435F1001; MP958
V5853A2063 3/4 in. DN20 4.9 Cv 4.2 kvs Equal Sweat Stem up to 7.25 psi 50 kPa M6410A1029; M7410F1000;
Percentage (Female) close M6435A1004; M7435F1001; MP958
V5863A1006 3/4 in. DN20 2.9 Cv 2.5 kvs Equal Female Stem up to 34 psi 234 kPa M6410A1029; M6435A1004;
Percentage NPT close M7410F1000; M7435F1001
V5863A1014 3/4 in. DN20 4.9 Cv 4.2 kvs Equal Female Stem up to 34 psi 234 kPa M6410A1029; M7410F1000;
Percentage NPT close M6435A1004; M7435F1001
V5863A2004 1/2 in. DN15 0.29 Cv 0.25 kvs Equal Female Stem up to 116 psi 800 kPa M6410A1029; M6435A1004;
Percentage NPT close M7410F1000; M7435F1001; MP958
V5863A2012 1/2 in. DN15 0.47 Cv 0.41 kvs Equal Female Stem up to 116 psi 800 kPa M6410A1029; M7410F1000;
Percentage NPT close M6435A1004; M7435F1001; MP958
V5863A2020 1/2 in. DN15 0.74 Cv 0.64 kvs Equal Female Stem up to 36 psi 248 kPa M6410A1029; M6435A1004;
Percentage NPT close M7410F1000; M7435F1001; MP958
V5863A2038 1/2 in. DN15 1.2 Cv 1.0 kvs Equal Female Stem up to 36 psi 248 kPa M6410A1029; M7410F1000;
Percentage NPT close M6435A1004; M7435F1001; MP958
V5863A2046 1/2 in. DN15 1.9 Cv 1.6 kvs Equal Female Stem up to 34 psi 234 kPa M6410A1029; M6435A1004;
Percentage NPT close M7410F1000; M7435F1001; MP958
V5863A2053 3/4 in. DN20 2.9 Cv 2.5 kvs Equal Female Stem up to 7.25 psi 50 kPa M6410A1029; M7410F1000;
Percentage NPT close M6435A1004; M7435F1001; MP958
V5863A2061 3/4 in. DN20 4.9 Cv 4.2 kvs Equal Female Stem up to 7.25 psi 50 kPa M6410A1029; M6435A1004;
Percentage NPT close M7410F1000; M7435F1001; MP958
V5863A3002 1 in. DN25 5.5 Cv 4.8 kvs Linear Female Stem up to 232 psi 1600 M6410A3017; M7410F3006;
NPT close port kPa M6435A3000; M7435F3007
A to AB
V5863A3010 1 in. DN25 7.8 Cv 6.7 kvs Linear Female Stem up to 232 psi 1600 M6410A3017; M7410F3006;
NPT close port kPa M6435A3000; M7435F3007
A to AB
V5863A3028 1 in. DN25 11.0 Cv 9.5 kvs Linear Female Stem up to 232 psi 1600 M6410A3017; M7410F3006;
NPT close port kPa M6435A3000; M7435F3007
A to AB

666 customer.honeywell.com 70-6910


Cartridge Globe Valves

Controls
Maximum Close-

Home
Valve Size Flow Capacity off Pressure
Flow Connec- Valve
Product Number (inch) DN (Cv) (Kv) Characteristic tion Type Action (psi) (kPa) Used With
V5863A3036 1 1/4 in. DN32 18 Cv 15.6 kvs Linear Female Stem up to 174 psi 1200 M6410A3017; M7410F3006;
NPT close port kPa M6435A3000; M7435F3007
A to AB
V5863A3044 1 1/2 in. DN40 25 Cv 21.6 kvs Linear Female Stem up to 145 psi 1000 M6410A3017; M7410F3006;

Indoor Air Quality


NPT close port kPa M6435A3000; M7435F3007
A to AB

Cartridge Globe Valve Accessories


Product Number Description Used With

Combustion Controls
WV108B Brush Tool for Valve Cleaning 1/2 in. and 3/4 in. V5852/V5853/V5862/V5863 V5862; V5853; V5852; V5863
WV108M Insert Replacement Tool for 1/2 in. and 3/4 in. V5852/V5853/V5862/V5863 V5853; V5862; V5852; V5863

Residential
Cartridge Globe Valve Replacement Parts
Product Number Description Used With
0902807 Replacement Insert for 1/2 in. V5852/V5862, 1.9Cv Interchangeable with 0902808 V5852A2056; V5862A2054

Hydronic Controls
0902808 Replacement Insert for 1/2 in. V5852/V5862, 1.2 Cv Interchangeable with 0902807 V5852A2049; V5862A2047
0902809 Replacement Insert for 1/2 in. V5852/V5862, 0.74 Cv Interchangeable with 0902810 or V5852A2031; V5862A2039
090212
0902810 Replacement Insert for 1/2 in. V5852/V5862, 0.47 Cv Interchangeable with 0902809 or V5852A2023; V5862A2021
090212
0902811 Replacement Insert for 1/2 in. V5852/V5862, 0.29 Cv V5852A2015; V5862A2013
0902812 Replacement Insert for 1/2 in. V5852/V5862, 0.19 Cv Interchangeable with 0902809 or V5852A2007; V5862A2005
090210
0902814 Replacement Insert for 3/4 in. V5852/V5862, 2.9 Cv Interchangeable with 0902815 V5852A2064; V5862A2062

Controls
Water
0902815 Replacement Insert for 3/4 in. V5852/V5862, 4.9 Cv Interchangeable with 0902814 V5852A2072; V5862A2070
0902821 Replacement Insert for 1/2 in. V5853/V5863, 0.29 Cv Interchangeable with 0902822 or V5853A2006; V5863A2004
0902823 or 0902824
0902822 Replacement Insert for 1/2 in. V5853/V5863, 0.47 Cv Interchangeable with 0902821 or V5853A2014; V5863A2012
0902823 or 0902824
0902823 Replacement Insert for 1/2 in. V5853/V5863, 0.74 Cv Interchangeable with 0902821 or V5853A2022; V5863A2020

Building Automation
0902822 or 0902824
0902824 Replacement Insert for 1/2 in. V5853/V5863, 1.2 Cv Interchangeable with 0902821 or V5853A2030; V5863A2038
0902822 or 0902823
0902825 Replacement Insert for 1/2 in. V5853/V5863, 1.9 Cv Interchangeable with 0902827 V5853A2048; V5863A2046
0902827 Replacement Insert for 3/4 in. V5853/V5863, 4.9 Cv Interchangeable with 0902825 V5853A1016; V5853A2063; V5863A1014;
V5863A2061; V5853A2063; V5963A2061
0903827 Replacement Packing for 1 in. V5862/63 V5862A3003; V5862A3011; V5862A3029;
V5863A3002; V5863A3010; V5863A3028
0903828 Replacement Packing for 1-1/4 in. V5862/63 V5862A3037; V5863A3036

Components
Commercial
0903829 Replacement Packing for 1-1/2 in. V5862/63 V5862A3045; V5863A3044

Pneumatic Controls
Industrial Combustion
Controls

70-6910 667
Cartridge Cage Valves
VCZA; VCZB Two-way Cartridge Cage Valves

Sweat Connection Sweat Connection Sweat Connection

NPT Connection NPT Connection NPT Connection


Two-way Cartridge Cage Valves are intended for hydronic • Quick open, linear, and equal percentage flow characteristics
applications in a normal indoor environment to control the flow of available
hot water or chilled water glycol solution to 60% concentration. • Bi-directional installation
These valves are designed for zone control of heating/cooling • 3000-series valves for floating and modulating non-fail safe
systems, or to control individual fan coil, baseboard radiator or applications
convector applications. Depending on the model selected they can • 1000-series valves for two-position control
be controlled by SPST or SPDT two position controller, tristate • High close-off rating independent of Cv
(floating), or modulating proportional controller. For best control, • Available with a variety of North American and international pipe
outdoor temperature compensation of supply water temperature is fittings
recommended. For trouble-free operation of the product, good • No tools required for actuator installation or removal
installation practice must include initial system flushing, chemical • Actuator removal does not require draining system
water treatment, and the use of a 50 micron (or finer) system side • Service is by replacement of cartridge, not valve body
stream filter(s). Remove all filters before flushing. • Cartridge replacement rebuilds valve to factory-new condition.
Valve Type: Cartridge Cage Valve Materials
Valve Action: Stem up to close A port (Body): Bronze
Body Pattern: Two-way, Straight-through (Stem): Stainless Steel
Connection Type: Sweat (Seat): EPDM O-ring seals on Noryl piston
Controlled Fluid: Chilled or hot water with up to 60% Glycol (Cartridge): Ryton®, Noryl® engineering plastic
Maximum Safe Operating Pressure: 300 psi (2068 kPA (20 Bar)) (Packing): EPDM rubber
Maximum Differential Pressure Ratings (Close-off): (414 kPa (4 Includes: Cartridge installation wrench
bar)); 60 psi Approvals:
Fluid Temperature Range: 34 F to 203 F (1 C to 95 C) Canadian Standards Association: CSA Certified
Ambient Temperature Range: 32 F to 150 F (0 C to 65 C)
Stem Travel: 0.4 in. (10 mm) Accessories:
40007029-002 Wrench for cartridge (included with sweat valves and all
replacement cartridges)
Valves with Linear Flow Characteristic

Flow Timing (sec,


Valve Size Capacity min.) when
used with VC Connection
Product Number (inch) DN (Cv) (Kv) series Actuator Type Actuation Comments Used With
VCZAA1100 1/2 in. DN15 3.5 Cv 3.03 kvs On/Off models Sweat Purchase Characterized cartridge; Can VC actuators,
with 6 seconds separately be controlled by either a low or On-Off Type
a line voltage SPDT or SPST or
floating controller
VCZAA3100 1/2 in. DN15 3.5 Cv 3.03 kvs 2 minutes Sweat Proportional non- characterized cartridge for use VC6930/31/34;
fail safe, purchase with non-fail safe floating and VC7930/31/34
separately modulating actuators
VCZAD1100 1/2 in. DN15 3.1 Cv 2.66 kvs On/Off models Flare Purchase Characterized cartridge; Can VC actuators,
with 6 seconds separately be controlled by either a low or On-Off Type
a line voltage SPDT or SPST or
floating controller

668 customer.honeywell.com 70-6910


Cartridge Cage Valves

Controls
Flow Timing (sec,

Home
Valve Size Capacity min.) when
used with VC Connection
Product Number (inch) DN (Cv) (Kv) series Actuator Type Actuation Comments Used With
VCZAE1100 1/2 in. DN15 3.2 Cv 2.74 kvs On/Off models Inverted Purchase Characterized cartridge; Can VC actuators,
with 6 seconds Flare separately be controlled by either a low or On-Off Type
a line voltage SPDT or SPST or
floating controller

Indoor Air Quality


VCZAL1100 3/4 in. DN20 4.7 Cv 4.0 kvs On/Off models Female NPT Purchase Characterized cartridge; Can VC actuators,
with 6 seconds separately be controlled by either a low or On-Off Type
a line voltage SPDT or SPST or
floating controller
VCZAL3100 3/4 in. DN20 4.7 Cv 4.0 kvs 2 minutes Female NPT Proportional non- characterized cartridge for use VC6930/31/34;
fail safe, purchase with non-fail safe floating and VC7930/31/34
separately modulating actuators
VCZAM1100 3/4 in. DN20 4.6 Cv 3.9 kvs On/Off models Sweat Purchase Characterized cartridge; Can VC actuators,

Combustion Controls
with 6 seconds separately be controlled by either a low or On-Off Type
a line voltage SPDT or SPST or

Residential
floating controller
VCZAM3100 3/4 in. DN20 4.7 Cv 4.0 kvs 2 minutes Sweat Proportional non- characterized cartridge for use VC6930/31/34;
fail safe, purchase with non-fail safe floating and VC7930/31/34
separately modulating actuators
VCZAR1100 1 in. DN25 6.6 Cv 5.7 kvs On/Off models Female NPT Purchase Characterized cartridge; Can VC actuators,
with 6 seconds separately be controlled by either a low or On-Off Type
a line voltage SPDT or SPST or
floating controller

Hydronic Controls
VCZAR3100 1 in. DN20 6.6 Cv 5.7 kvs 2 minutes Female NPT Proportional non- characterized cartridge for use VC6930/31/34;
fail safe, purchase with non-fail safe floating and VC7930/31/34
separately modulating actuators
VCZAS1100 1 in. DN25 6.6 Cv 5.7 kvs On/Off models Sweat Purchase Characterized cartridge; Can VC actuators,
with 6 seconds separately be controlled by either a low or On-Off Type
a line voltage SPDT or SPST or
floating controller
VCZAS3100 1 in. DN20 6.6 Cv 5.7 kvs 2 minutes Sweat Proportional non- characterized cartridge for use VC6930/31/34;
fail safe, purchase with non-fail safe floating and VC7930/31/34
separately modulating actuators

Controls
VCZBB1100 1/2 in. DN15 3.5 Cv 3.03 kvs On/Off models Female NPT Purchase Characterized cartridge; Can VC actuators,

Water
with 6 seconds separately be controlled by either a low or On-Off Type
a line voltage SPDT or SPST or
floating controller
VCZBB3100 1/2 in. DN15 3.5 Cv 3.03 kvs 2 minutes Female NPT Proportional non- characterized cartridge for use VC6930/31/34;
fail safe, purchase with non-fail safe floating and VC7930/31/34
separately modulating actuators

Building Automation
VCZBD1100 1 1/4 in. DN32 7.0 Cv 6.5 kvs On/Off models Female NPT Purchase Characterized cartridge; Can VC actuators,
with 6 seconds separately be controlled by either a low or On-Off Type
a line voltage SPDT or SPST or
floating controller
VCZBD3100 1 1/4 in. DN32 7.0 Cv 6.5 kvs 2 minutes Female NPT Proportional non- characterized cartridge for use VC6930/31/34;
fail safe, purchase with non-fail safe floating and VC7930/31/34
separately modulating actuators
VCZBE1100 1 1/4 in. DN32 7.0 Cv 6.5 kvs On/Off models Sweat Purchase Characterized cartridge; Can VC actuators,
with 6 seconds separately be controlled by either a low or On-Off Type
a line voltage SPDT or SPST or
floating controller

Components
Commercial
VCZBE3100 1 1/4 in. DN32 7.0 Cv 6.5 kvs 2 minutes Sweat Proportional non- characterized cartridge for use VC6930/31/34;
fail safe, purchase with non-fail safe floating and VC7930/31/34
separately modulating actuators

Pneumatic Controls
Industrial Combustion
Controls

70-6910 669
Cartridge Cage Valves
Valves with Modified Equal Percent Flow Characteristic

Flow Timing (sec,


Valve Size Capacity min.) when
used with VC Connection
Product Number (inch) DN (Cv) (Kv) series Actuator Type Actuation Comments Used With
VCZAA3400 1/2 in. DN15 2.3 Cv 1.98 kvs 2 minutes Sweat Proportional non- characterized cartridge for use VC6930/31/34;
fail safe, purchase with non-fail safe floating and VC7930/31/34
separately modulating actuators
VCZAA3500 1/2 in. DN15 0.7 Cv 0.6 kvs 2 minutes Sweat Proportional non- characterized cartridge for use VC6930/31/34;
fail safe, purchase with non-fail safe floating and VC7930/31/34
separately modulating actuators
VCZAA3600 1/2 in. DN15 1.3 Cv 1.1 kvs 2 minutes Sweat Proportional non- characterized cartridge for use VC6930/31/34;
fail safe, purchase with non-fail safe floating and VC7930/31/34
separately modulating actuators
VCZAA3800 1/2 in. DN15 1.9 Cv 1.64 kvs 2 minutes Sweat Proportional non- characterized cartridge for use VC6930/31/34;
fail safe, purchase with non-fail safe floating and VC7930/31/34
separately modulating actuators
VCZAL3400 3/4 in. DN20 3.9 Cv 3.4 kvs 2 minutes Female NPT Proportional non- characterized cartridge for use VC6934,
fail safe, purchase with non-fail safe floating and VC7934
separately modulating actuators
VCZAL3800 3/4 in. DN20 3.1 Cv 2.6 kvs 2 minutes Female NPT Proportional non- characterized cartridge for use VC6934,
fail safe, purchase with non-fail safe floating and VC7934
separately modulating actuators
VCZAM3400 3/4 in. DN20 3.9 Cv 3.4 kvs 2 minutes Sweat Proportional non- characterized cartridge for use VC6934,
fail safe, purchase with non-fail safe floating and VC7934
separately modulating actuators
VCZAM3800 3/4 in. DN20 3.1 Cv 2.6 kvs 2 minutes Sweat Proportional non- characterized cartridge for use VC6934,
fail safe, purchase with non-fail safe floating and VC7934
separately modulating actuators
VCZAR3400 1 in. DN20 4.2 Cv 3.6 kvs 2 minutes Female NPT Proportional non- characterized cartridge for use VC6934,
fail safe, purchase with non-fail safe floating and VC7934
separately modulating actuators
VCZAS3400 1 in. DN20 4.2 Cv 3.6 kvs 2 minutes Sweat Proportional non- characterized cartridge for use VC6934,
fail safe, purchase with non-fail safe floating and VC7934
separately modulating actuators
VCZBB3400 1/2 in. DN15 2.3 Cv 1.98 kvs 2 minutes Female NPT Proportional non- characterized cartridge for use VC6934,
fail safe, purchase with non-fail safe floating and VC7934
separately modulating actuators
VCZBB3500 1/2 in. DN15 0.7 Cv 0.6 kvs 2 minutes Female NPT Proportional non- characterized cartridge for use VC6930/31/34;
fail safe, purchase with non-fail safe floating and VC7930/31/34
separately modulating actuators
VCZBB3600 1/2 in. DN15 1.3 Cv 1.1 kvs 2 minutes Female NPT Proportional non- characterized cartridge for use VC6930/31/34;
fail safe, purchase with non-fail safe floating and VC7930/31/34
separately modulating actuators
VCZBB3800 1/2 in. DN15 1.9 Cv 1.64 kvs 2 minutes Female NPT Proportional non- characterized cartridge for use VC6930/31/34;
fail safe, purchase with non-fail safe floating and VC7930/31/34
separately modulating actuators

670 customer.honeywell.com 70-6910


Cartridge Cage Valves
Dimensions in inches (millimeters)

Controls
Home
2-3/4 (68)
3-3/4 (94)

Indoor Air Quality


3-9/16
(90)
D

Combustion Controls
A B

Residential
C
C D C D
Pipe Fitting Sizes 4 in. mm in. mm Pipe Fitting Sizes 4 in. mm in. mm

Hydronic Controls
North American Standard
3/8" FLARE 1 3-7/8 98 4-3/8 111 1/2" BSPP (int.) 2 3-7/8 98 4-3/8 111
1/2" SWEAT 3-1/2 89 1/2" BSPT (int.)
1/2" FLARE 1 3-7/8 98 3/4" BSPP (int.) 3-11/16 94 4-7/16 113
1/2" INVERTED FLARE 1 3/4" BSPT (int.)
1/2" NPT (int.) 3/4" BSPP (ext.)
3/4" NPT (int.) 3-11/16 94 4-7/16 113 22 mm Compression 3 4-7/16 112
3/4" SWEAT 1" BSPP (int.) 3-11/16 94
1" NPT (int.) 1" BSPP (ext.) 3-11/17 95 4-7/17 114
1" SWEAT 1" BSPT (int.) 3-11/16 94 4-7/16 113

Controls
Water
1-1/4" SWEAT 4-5/16 110 4-5/8 118 28 mm Compression 3 4-9/16 116
1-1/4" NPT (int.)

1 NO ADAPTERS M18942

2 SUITABLE FOR USE AS15 MM COMPRESSION FITTING

3 DIMENSIONS SHOWN WITH NUTS AND OLIVES INSTALLED

Building Automation
4 SOME MODELS NOT AVAILABLE IN ALL COUNTRIES

Components
Commercial

You might also like