100% found this document useful (1 vote)
155 views

Device Summary English

This document contains a list of devices for a gas turbine engine, including their designations, characteristics, and settings. It lists over 50 different devices such as solenoid valves, heaters, detectors, and switches that control processes like fuel control, water washing, ventilation, and ignition. Each device is identified by a unique item number, designation, and purpose code. Their electrical specifications and operating parameters are also provided.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
155 views

Device Summary English

This document contains a list of devices for a gas turbine engine, including their designations, characteristics, and settings. It lists over 50 different devices such as solenoid valves, heaters, detectors, and switches that control processes like fuel control, water washing, ventilation, and ignition. Each device is identified by a unique item number, designation, and purpose code. Their electrical specifications and operating parameters are also provided.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 14

SIZE DWG NO SH REV

A4 113A7969 1 D

Item Item
Devices Designation
PID TG
Solenoid valve for VA18-1 control.
0425 20AA-1 0983 Characteristics: Normal : 1 to 3 open ; 2 closed.
35 W | 125 VDC
Solenoid valve for VA22-1 control.
0425 20AB-1 0922 Characteristics: Normal : 1 to 3 open ; 2 closed.
35 W | 125 VDC
Compressor Bleed Solenoid Valve
0417 20CB-1 1071
Characteristics: Normal : B to C Open ; A closed
Fuel pump clutch solenoid
0424 20CF-1 0601 Characteristics: Normal : NO
160W(max) | 100-125VDC
Trip Solenoid Valve for Gas Control Valve (VGC-1)
0422 20FGC-1 0509 Characteristics : Normal : NO
125 VDC
Fuel Gas Stop Valve Solenoid Valve
0422 20FGS-1 0507 Characteristics : Normal : NO
125 VDC
Liquid fuel stop gas solenoid
0424 20FL-1 1019
Characteristics: Normal : NO
Solenoid valve. Command the VA99-32 valve
0494 20IA-31 E021 Characteristics: Normal : 1 to 2 closed.
12 W | 125 VDC |
purge fuel liquid solenoid valve
0424 20PF-100 0961
Characteristics : Normal : port OH4 closed
Solenoid valve for VA13-1 control.
Characteristics: Normal : 1 to 3 open ; 2 closed.
0477 20PG-1 0918
35 W | 125 VDC
Settings: A Needle-Valve is installed upstream of 20PG-1 in order to adjust VA13-1 Time Opening at 30 seconds.
Solenoid valve for VA13-2 control.
Characteristics: Normal : 1 to 3 open ; 2 closed.
0477 20PG-2 0918
35 W | 125 VDC
Settings: A Needle-Valve is installed upstream of 20PG-1 in order to adjust VA13-1 Time Opening at 30 seconds.
Solenoid valve for VA19-1 control.
0477 20PL-1 918T Characteristics: Normal : 1 to 3 open ; 2 closed.
35 W | 125 VDC
Torque Converter Fill / Drain Solenoid Valve
0421 20TU-1 0605
Characteristics: Normal : NC
Turbine compressor IGV solenoid valve
0469 20TV-1 1019
Characteristics: Normal : NO
Motor Valve Off-Line Compressor Water Wash
0442 20TW-1 0953 Characteristics: 92 W | 115 VAC | 50 Hz | 1 PH |
Fail safe to close
Motor Valve Turbine Water Wash
0442 20TW-2 0983 Characteristics: 230 W | 115 VAC | 50 Hz | 1 PH |
Fail safe to close
Motor Valve On-Line Compressor Water Wash
0442 20TW-3 0953 Characteristics: 92 W | 115 VAC | 50 Hz | 1 PH |
Fail safe to close
Fuel Gas Vet solenoid Valve
0422 20VG-1 0911 Characteristics: Normal : NO
125 VDC
Vent Solenoid Valve of inter-valve cavity VA13-1 and VA13-2.
0477 20VG-2 0918 Characteristics: Normal : NO
125 W | 125 VDC
Solenoid valve for Water Injection Control valve VC4-1
0462 20WN-1 A035
Characteristics : Normal : NO
Motor space heater for 88AB-1
0425 23AB-1 1047
Characteristics: 0.05 kW | 230 VAC | 50 Hz | 1 PH |
Anti-condensation heater for motor 88BT-1
0436 23BT-1 1605
Characteristics: 0,05 kW | 230 VAC | 50 Hz | 1 PH |
Anti-condensation heater for motor 88BT-2
0436 23BT-2 1605
Characteristics: 0,05 kW | 230 VAC | 50 Hz | 1 PH |
Cranking Motor Space Heater
0421 23CR-1 0603
Characteristics: 180 W | 230 VAC | 50 Hz | 1 PH |

GENERAL ELECTRIC COMPANY SIZE CAGE CODE DWG NO

g GE Energy Products - Europe


A4
113A7969

DRAWN M. JEZEQUEL SECTION 01E

SCALE SHEET 1
SIZE DWG NO SH REV
A4 113A7969 2 D

Item Item
Devices Designation
PID TG
Cranking Motor Space Heater
0421 23CR-2 0603
Characteristics: 180 W | 230 VAC | 50 Hz | 1 PH |
Cranking Motor Space Heater
0421 23CR-3 0603
Characteristics: 180 W | 230 VAC | 50 Hz | 1 PH |
Accessory compartment heater
0436 23HA-1 1137
Characteristics: 18 kW | 400 VAC | 50 Hz | 3 PH |
Heater hydraulic oil pump motor
0434 23HQ-1 0628
Characteristics: 0,05 kW | 230 VAC | 50 Hz | 1 PH |
Acoustic TG enclosure Heater
0436 23HT-1 1605
Characteristics: 18 kW | 400 VAC | 50 Hz | 3 PH |
Air inlet water injection compartment heater
0436 23JS-3 1605
Characteristics : 5 kW | 400 VAC | 50 Hz | 3 PH |
Air inlet water injection compartment heater
0436 23JS-4 1605
Caractéristiques : 5 kW | 400 VAC | 50 Hz | 3 PH |
Motor space heater for 88QA-1
0416 23QA-1 1006
Characteristics: 0.05 kW | 230 VAC | 50 Hz | 1 PH |
Immersion heater Lube Oil Tank
0416 23QT-1 0938
Characteristics: 10,2 kW | 400 VAC | 50 Hz | 3 PH |
Immersion heater Lube Oil Tank
0416 23QT-2 0938
Characteristics: 10,2 kW | 400 VAC | 50 Hz | 3 PH |
Anti-condensation heater of 88QV-1
0416 23QV-1 A098
Characteristics: 0.05 kW | 230 VAC | 50 Hz | 1 PH |
Turning Gear Motor Space Heater
0421 23TG-1 0603
Characteristics: 0.05 kW | 230 VAC | 50 Hz | 1 PH |
Anti-condensation heater for motor 88TK-2
0417 23TK-1 1233
Characteristics: 0.05 kW | 230 VAC | 50 Hz | 1 PH |
Anti-condensation heater for motor 88TK-2
0417 23TK-2 1233
Characteristics: 0.05 kW | 230 VAC | 50 Hz | 1 PH |
Anti-condensation heater for motor 88WN-1
0462 23WN-1 A035
Characteristics: 0,05 kW | 230 VAC | 50 Hz | 1 PH |
Water injection compartment heater
0436 23WR-1 1605
Caractéristiques : 3 kW | 400 VAC | 50 Hz | 3 PH
Water injection compartment heater
0436 23WR-2 1605
Caractéristiques : 3 kW | 400 VAC | 50 Hz | 3 PH
Thermostat, lower temperature in accessory compartment
0436 26HA-1 1137 Characteristics: Normal : NO; measure range : 2 to 50C° (35,6 to 122°F)
Settings : 15°C
Thermostat, low temperature in acoustic enclosure
0436 26HT-1 1605 Characteristics: Normal : NO ; measure range : 2 to 50C° (35,6 to 122°F)
Settings : 15°C
Water injection compartment heater
0436 26WR-1 1605
Settings : +10°C mini
0415 28FD-10 1121 Flame detector chamber 10
0415 28FD-11 1121 Flame detector chamber 11
0415 28FD-4 1121 Flame detector chamber 4
0415 28FD-5 1121 Flame detector chamber 5
Diagnostic ignition exciter switch
0415 30SG-1 1213 Characteristics : Normal : NO
125 VDC
GT enclosure ventilation damper limit switch
0436 33BT-1 1605 Characteristics: Normal : NO
Settings: damper closed : limit switch activated and contact closed
GT enclosure ventilation damper limit switch
0436 33BT-2 1605 Characteristics: Normal : NO
Settings: damper closed : limit switch activated and contact closed
11 stage compressor Bleed Valve Limit Switch
0417 33CB-1 1022 Characteristics: Normal : NO
Settings: Valve open : limit switch activated, contact closed
11 stage compressor Bleed Valve Limit Switch
0417 33CB-2 1022 Characteristics: Normal : NO
Settings: Valve open : limit switch activated, contact closed
11 stage compressor Bleed Valve Limit Switch
0417 33CB-3 1022 Characteristics: Normal : NO
Settings: Valve open : limit switch activated, contact closed

GENERAL ELECTRIC COMPANY SIZE CAGE CODE DWG NO

g GE Energy Products - Europe


A4
113A7969

DRAWN M. JEZEQUEL SECTION 01E

SCALE SHEET 2
SIZE DWG NO SH REV
A4 113A7969 3 D

Item Item
Devices Designation
PID TG
11 stage compressor Bleed Valve Limit Switch
0417 33CB-4 1022 Characteristics: Normal : NO
Settings: Valve open : limit switch activated, contact closed
Liquid fuel stop valve limit switch (bc)
0424 33FL-1 0511 Characteristics: Normal: NO
Settings: Valve closed : switch actuated, contact closed
Water injection compartment ventilation damper limit switch
0436 33JS-1 1605 Characteristics: Normal : NO
Settings: damper closed : limit switch activated and contact closed
Water injection compartment ventilation damper limit switch
0436 33JS-2 1605 Characteristics: Normal : NO
Settings: damper closed : limit switch activated and contact closed
purge fuel liquid valve limit switch VP-1
0424 33PF-1 0961 Characteristics : Normal : NO
Settings : Valve closed : switch actuated and contact closed
purge fuel liquid valve limit switch VP-2
0424 33PF-2 0961 Characteristics : Normal : NO
Settings : Valve closed : switch actuated and contact closed
VA13-1 Close Position Limit Switch.
0477 33PG-1 0918 Characteristics: Normal: NO
Settings: Valve closed : switch actuated, contact closed.
VA13-1 Open Position Limit Switch.
0477 33PG-2 0918 Characteristics: Normal: NO
Settings: Valve open : switch actuated, contact closed
VA13-2 Close Position Limit Switch.
0477 33PG-3 0918 Characteristics: Normal: NO
Settings: Valve closed : switch actuated, contact closed.
VA13-2 Open Position Limit Switch.
0477 33PG-4 0918 Characteristics: Normal: NO
Settings: Valve open : switch actuated, contact closed
Torque Converter Solenoid Valve Limit Switch
0421 33TC-1 0605 Characteristics: Normal : NO
Settings: Switch activated with 20TU-1 de energized – Contact closed
Torque Converter Low Torque Limit Switch
0421 33TM-5 0605
Settings: Setup at 2 tr (range 0-31 tr)
Torque Converter High Torque Limit Switch
0421 33TM-6 0605
Settings: Setup at 28 tr (range 0-31 tr)
Load compartment ventilation damper limit switch
0436 33VG-1 1605 Characteristics: Normal : NO
Settings: damper closed : limit switch activated and contact closed
Limit Switch on Solenoid Valve 20VG-1
0422 33VG-11 0911 Characteristics: See specifications
Settings: Valve open :limit switch activated and contact closed
Load compartment ventilation damper limit switch
0436 33VG-2 1605 Characteristics: Normal : NO
Settings: damper closed : limit switch activated and contact closed
VC4-1 control valve limit switch
0462 33WN-1 A035 Characteristics: Normal: NO
Settings: Valve full opened = limit switch actuated, contact closed.
VC4-1 control valve limit switch
0462 33WN-2 A035 Characteristics: Normal: NO
Settings: Valve full closed = limit switch actuated, contact closed.
Vibration Sensor
0415 39V-1A 1218
Characteristics: For 25,4 mm/s (1 in/s), 150 ± 4,5 mV peak
Vibration Sensor
0415 39V-1B 1218
Characteristics: For 25,4 mm/s (1 in/s), 150 ± 4,5 mV peak
Vibration Sensor
0415 39V-2A 1218
Characteristics: For 25,4 mm/s (1 in/s), 150 ± 4,5 mV peak
Vibration Sensor
0415 39V-3A 1218
Characteristics: For 25,4 mm/s (1 in/s), 150 ± 4,5 mV peak
Vibration Sensor
0415 39V-3B 1218
Characteristics: For 25,4 mm/s (1 in/s), 150 ± 4,5 mV peak
Vibration Sensor
0415 39VS-11 0235 Characteristics: Output proximitor : 7,87 V/mm
Settings: Regulation at 1,14 mm (0,045 in)

GENERAL ELECTRIC COMPANY SIZE CAGE CODE DWG NO

g GE Energy Products - Europe


A4
113A7969

DRAWN M. JEZEQUEL SECTION 01E

SCALE SHEET 3
SIZE DWG NO SH REV
A4 113A7969 4 D

Item Item
Devices Designation
PID TG
Vibration Sensor
0415 39VS-12 0235 Characteristics: Output proximitor : 7,87 V/mm
Settings: Regulation at 1,14 mm (0,045 in)
Vibration Sensor
0415 39VS-31 1160 Characteristics: Output proximitor : 7,87 V/mm
Settings: Regulation at 1,14 mm (0,045 in)
Vibration Sensor
0415 39VS-32 1160 Characteristics: Output proximitor : 7,87 V/mm
Settings: Regulation at 1,14 mm (0,045 in)
Break glass unit accessory compartment
0426 43CP-1 1605
Characteristics: Normal : NO
Break glass unit GT compartment
0426 43CP-2 1605
Characteristics: Normal : NO
Break glass unit accessory compartment
0426 43CP-3 1605
Characteristics: Normal : NO
Break glass unit GT compartment
0426 43CP-4 1605
Characteristics: Normal : NO
Break glass unit load compartment
0426 43CP-5 1605
Characteristics: Normal : NO
0424 43FUOP 1103 valve VP-1 and VP-2 push button
0442 43TW-1/PB 1105 Off-Line Water Wash Push button
0442 43TW-2/PB 1105 Turbine Water Wash Push button
Thermostatic fire detector Accessory compartment
0426 45FA-1A 1104
Characteristics: Normal : NO Closed : 163 ± 14°C (325 ± 25°F)
Thermostatic fire detector Accessory compartment
0426 45FA-1B 1104
Characteristics: Normal : NO Closed : 163 ± 14°C (325 ± 25°F)
Thermostatic fire detector Accessory compartment
0426 45FA-2A 1104
Characteristics: Normal : NO Closed : 163 ± 14°C (325 ± 25°F)
Thermostatic fire detector Accessory compartment
0426 45FA-2B 1104
Characteristics: Normal : NO Closed : 163 ± 14°C (325 ± 25°F)
Thermostatic fire detector Turbine compartment
0426 45FT-1A 1103
Characteristics: Normal : NO Closed : 316 ± 14°C (600 ± 25°F)
Thermostatic fire detector Turbine compartment
0426 45FT-1B 1103
Characteristics: Normal : NO Closed : 316 ± 14°C (600 ± 25°F)
Thermostatic fire detector Turbine compartment
0426 45FT-2A 1154
Characteristics: Normal : NO Closed : 316 ± 14°C (600 ± 25°F)
Thermostatic fire detector Turbine compartment
0426 45FT-2B 1154
Characteristics: Normal : NO Closed : 316 ± 14°C (600 ± 25°F)
Thermostatic fire detector Turbine compartment
0426 45FT-3A 1154
Characteristics: Normal : NO Closed : 316 ± 14°C (600 ± 25°F)
Thermostatic fire detector Turbine compartment
0426 45FT-3B 1154
Characteristics: Normal : NO Closed : 316 ± 14°C (600 ± 25°F)
Thermostatic fire detector Load compartment
0426 45FT-8A 1160
Characteristics: Normal : NO Closed : 385 ± 14°C (725 ± 25°F)
Thermostatic fire detector Load compartment
0426 45FT-8B 1160
Characteristics: Normal : NO Closed : 385 ± 14°C (725 ± 25°F)
Thermostatic fire detector Load compartment
0426 45FT-9A 1160
Characteristics: Normal : NO Closed : 316 ± 14°C (600 ± 25°F)
Thermostatic fire detector Load compartment
0426 45FT-9B 1160
Characteristics: Normal : NO Closed : 316 ± 14°C (600 ± 25°F)
Gas detector Gas Auxiliary compartment
0474 45HA-1 1153
Characteristics: Range : 0 – 20% LEL
Gas detector in Auxiliary Compartment
0474 45HA-2 1153
Characteristics: Range : 0 – 20% LEL
Gas detector Gas in Auxiliary Compartment.
0474 45HA-3 1153
Characteristics: Range : 0 – 20% LEL
Gas detector Gas in Gas cabinet Module.
0474 45HA-4 1605
Characteristics: Range : 0 – 20% LEL
Gas detector Gas in Gas cabinet Module.
0474 45HA-5 1605
Characteristics: Range : 0 – 20% LEL
Gas detector Gas in Gas cabinet Module.
0474 45HA-6 1605
Characteristics: Range : 0 – 20% LEL
Gas detector Turbine Compartment
0474 45HT-1 1154
Characteristics: Range : 0 – 20% LEL

GENERAL ELECTRIC COMPANY SIZE CAGE CODE DWG NO

g GE Energy Products - Europe


A4
113A7969

DRAWN M. JEZEQUEL SECTION 01E

SCALE SHEET 4
SIZE DWG NO SH REV
A4 113A7969 5 D

Item Item
Devices Designation
PID TG
Gas detector Turbine Compartment
0474 45HT-2 1154
Characteristics: Range : 0 – 20% LEL
Gas detector Turbine Compartment
0474 45HT-3 1154
Characteristics: Range : 0 – 20% LEL
Gas detector Turbine Compartment ventilation duct
0474 45HT-4 1605
Characteristics: Range : 0 – 20% LEL
Gas detector Turbine Compartment ventilation duct
0474 45HT-5 1605
Characteristics: Range : 0 – 20% LEL
Gas detector Turbine Compartment ventilation duct
0474 45HT-6 1605
Characteristics: Range : 0 – 20% LEL
Emergency Stop Button accessory compartment
0426 5E-1 1104
Characteristics: Normal : NC
Emergency Stop Button accessory compartment
0426 5E-2 1104
Characteristics: Normal : NC
Pressure switch of the air circuit
0494 63AF-31 E021 Characteristics: Normal : NC
Settings : opening : 3 ± 0.25 bar (43.5 ± 4 PSI)
GT compressed air inlet filter low pressure switch
Characteristics: Normal : NC
0471 63CA-1 A040
Settings: Increase closed at : 6 bars ± 0,5 bar
Decrease opened at : 5,5 bars ± 0,5 bar
GT inlet air system differential pressure switch
0471 63CS-2A A040 Characteristics: Normal : NC
Settings: Increase open at : 23 mbar ± 0,5 mbar
GT inlet air system differential pressure switch
0471 63CS-2B A040 Characteristics: Normal : NC
Settings: Increase open at : 23 mbar ± 0,5 mbar
Liquid fuel pressure upstream of stop valve
Characteristics: Normal: NO
0424 63FL-2 0926
Settings: DEC opened = 35 ± 1 psig
INC closed = 40 ± 2 psig
Hydraulic filter differential Pressure Alarm
Characteristics: Normal : NC
0434 63HF-1 0926
Settings: Inc open at 4,13 ± 0,2 bar (60 ± 3 psi)
Dec close at 2,75 ± 1,03 bar (40 ± 15 psi)
Low hydraulic supply press. Aux hydraulic Pump start
Characteristics: Normal : NO
0434 63HQ-1 0926
Settings: Inc closed at 100 ± 3,1 bar (1450 ± 45 psi )
Dec open at 93 ± 1,7 bar (1350 ± 25 psi)
Fuel filter differential pressure alarm
0424 63LF-3 0992 Characteristics: NORMAL: NC
Settings: INC opened = 15 ± 1 psi
Pressure switch on VA13-1 & VA13-2 intervalves space.
Characteristics: Normal: NC
0477 63PG-1 0918
Settings: Increase open at 3,10 ± 0,13 bar (45 ± 2 psi)
For information, decrease close at 2,75 ± 0,13 bar (45 ± 2 psi)
Pressure switch on liquid fuel purge air.
Characteristics: Normal: NO
0477 63PL-21 918T
Settings: Increase close at 7 ± 0,25 bar (101 ± 4 psi)
For information decrease open at 5,6 ± 0,25 bar (81 ± 4 psi).
Low Lube Oil Pressure Alarm
Characteristics: Normal : NO
0416 63QA-2 0926
Settings: Dec. Open : 2,8 ± 0,07 bar (40,6 ± 1 psig)
(For Information : Inc. Close : 3,1 ± 0,14 bar ( 45 ± 2 psig))
Differential pressure switch Main Lube Oil Filter
Characteristics: Normal : NC
0416 63QQ-1 0926
Settings: Inc. Open : 1,03 ± 0,068 bar (15 ± 0,1 psig)
(For Information : Dec. Close : 0,9 ± 0,2 bar (13 ± 3 psig))
Mist eliminator lube oil filter differential pressure switch
0416 63QQ-10 A098 Characteristics: Normal : NC
Settings: Inc. open : 80 ± 3 mbar
Torque converter filter differential pressure
0416 63QQ-8 0916 Characteristics: Normal : NC
Settings: Inc. Open : 1,5 ± 0,2 bar (21,75 ± 3 psi)

GENERAL ELECTRIC COMPANY SIZE CAGE CODE DWG NO

g GE Energy Products - Europe


A4
113A7969

DRAWN M. JEZEQUEL SECTION 01E

SCALE SHEET 5
SIZE DWG NO SH REV
A4 113A7969 6 D

Item Item
Devices Designation
PID TG
Low Lube Oil Pressure generator side
Characteristics: Normal : NO
0416 63QT-2A ALT.
Settings: Dec. Open : 0,55 ± 0,021 bar (8 ± 0,3 psig)
(For Information : Inc. Close :0,62 ± 0,035 bar (9 ± 0,5 psig))
Turbine shell and exhaust frame blower discharge pressure switch
0417 63TK-1 A053 Characteristics: Normal : NO
Settings: Closed above 15 ± 3 inch H2O
Turbine shell and exhaust frame blower discharge pressure switch
0417 63TK-2 A053 Characteristics: Normal : NO
Settings: Closed above 15 ± 3 inch H2O
Gas cabinet ventilation pressure switch
0436 63VL 1605 Characteristics: Normal : NO
Settings: increase close at 25 ± 3 mm CE
Water injection Pump inlet pressure switch Characteristics: Normal: NO
0462 63WN-1 A035
Settings: Dec Open at 10.00 ± 0.20 PSI
Water injection Pump outlet pressure switch
0462 63WN-2 A035 Characteristics: Normal: NO
Settings: Dec Open at 580.000 ± 10.000 PSI
Water injection filter differential pressure switch
0462 63WN-3 A035 Characteristics: Normal: NC.
Settings : Inc Open factory set at 17 ± 2 PSID.
0424 65FP 0533 Liquid fuel pump (by pass valve) servo valve
0422 65GC-1 0541 Gas control valve servo valve
Level switch in the tank 501BA
0494 71FA-31 E021 Characteristics: Normal : NO
Settings: Opening on low level
Level switch in the aux tank
0494 71FA-32 E021 Characteristics: Normal : NO
Settings: Opening on low level
High level lube oil tank
0416 71QH-1 1038 Characteristics: Normal : NC
Settings: Incr. Open on high level. See lube oil schematic MLItem 416 for setting
Low level lube oil tank
0416 71QL-1 1038 Characteristics: Normal : NO
Settings: Decr. Open on low level. See lube oil schematic MLItem 416 for setting
Flow divider magnetic pickup
0424 77FD-1 0992
Settings: Gap : 0.23 ± 0.025 mm (0.009 inch ± 0.001 inch)
Flow divider magnetic pickup
0424 77FD-2 0992
Settings: Gap : 0.23 ± 0.025 mm (0.009 inch ± 0.001 inch)
Flow divider magnetic pickup
0424 77FD-3 0992
Settings: Gap : 0.23 ± 0.025 mm (0.009 inch ± 0.001 inch)
Speed Sensor
0415 77HT-1 0546
Settings: Air-gap : 1,27 ± 0,127 mm (0,05 ± 0,005 inch)
Speed Sensor
0415 77HT-2 0546
Settings: Air-gap : 1,27 ± 0,127 mm (0,05 ± 0,005 inch)
Speed Sensor
0415 77HT-3 0546
Settings: Air-gap : 1,27 ± 0,127 mm (0,05 ± 0,005 inch)
Speed Sensor
0415 77NH-1 0546
Settings: Air-gap : 1,27 ± 0,127 mm (0,05 ± 0,005 inch)
Speed Sensor
0415 77NH-2 0546
Settings: Air-gap : 1,27 ± 0,127 mm (0,05 ± 0,005 inch)
Speed Sensor
0415 77NH-3 0546
Settings: Air-gap : 1,27 ± 0,127 mm (0,05 ± 0,005 inch)
Vibration Sensor
0415 77RP-11 0235 Characteristics: Output proximitor : 7,87 V/mm
Settings: Regulation at 1,14 mm (0,045 in)
Atomizing air booster motor
0425 88AB-1 1047
Characteristics: 15 kW | 2925 rpm | 400 VAC | 50 Hz | 3 PH |
Cooling air fan motor – Acoustic enclosure
0436 88BT-1 1605
Characteristics: 15 kW | 1460 rpm | 400 VAC | 50 Hz | 3 PH |
Cooling air fan motor – Acoustic enclosure
0436 88BT-2 1605
Characteristics: 15 kW | 1460 rpm | 400 VAC | 50 Hz | 3 PH |
Electrical Cranking Motor
0421 88CR-1 0603
Characteristics: 1000 kW | 2973 rpm | 6,6 kV | 50 Hz | 3 PH |

GENERAL ELECTRIC COMPANY SIZE CAGE CODE DWG NO

g GE Energy Products - Europe


A4
113A7969

DRAWN M. JEZEQUEL SECTION 01E

SCALE SHEET 6
SIZE DWG NO SH REV
A4 113A7969 7 D

Item Item
Devices Designation
PID TG
Electric motor of the PFA-30 pump
0494 88FA-30 E021
Characteristics: 0,46 kW | 1500 rpm | 230 VAC | 50 Hz | 1 PH |
Electric motor of the PFA-31 pump
0494 88FA-31 E021
Characteristics: 0,37 kW | 1500 rpm | 400 VAC | 50 Hz | 3 PH |
Electric motor of the PFA-32 pump
0494 88FA-32 E021
Characteristics: 0,37 kW | 1500 rpm | 400 VAC | 50 Hz | 3 PH |
Flow divider starting motor
0424 88FM 0613
Characteristics: 0,37 kW | 1400 rpm | 400 VAC | 50 Hz | 3 PH |
(auxiliary) hydraulic supply pump motor
0434 88HQ-1 0628
Characteristics: 15 kW | 2925 rpm | 400 VAC | 50 Hz | 3 PH |
Cooling air fan motor – Air Atomization Water Injection compartment
0436 88JS-1 1605
Characteristics: 0.5 kW | 1400 rpm | 400 VAC | 50 Hz | 3 PH |
Cooling air fan motor – Air Atomization Water Injection compartment
0436 88JS-2 1605
Characteristics: 0.5 kW | 1400 rpm | 400 VAC | 50 Hz | 3 PH |
Auxiliary Lube oil pump motor
0416 88QA-1 1006
Characteristics: 90 kW | 3000 rpm | 400 | 50 Hz | 3 PH |
Emergency Lube Oil Pump Motor
0416 88QE-1 1007
Characteristics: 7,5 kW | 1750 rpm | 125 V | - Hz | DC |
Lube Oil Mist Eliminator Motor
0416 88QV-1 A098
Characteristics: 7,5 kW | 3000 rpm | 400 VAC | 50 Hz | 3 PH |
Turning Gear Electrical Motor
0421 88TG-1 0538 Characteristics: 30 kW | 725 rpm | 400 VAC | 50 Hz | 3 PH |
Settings: Not applicable
Turbine Exhaust Frame Cooling Fan Vent Motor
0417 88TK-1 1233
Characteristics: 45 kW | 2900 rpm | 400 VAC | 50 Hz | 3 PH |
Turbine Exhaust Frame Cooling Fan Vent Motor
0417 88TK-2 1233
Characteristics: 45 kW | 2900 rpm | 400 VAC | 50 Hz | 3 PH |
Torque adjuster drive motor
0421 88TM-1 0605
Characteristics: 1,5 kW | 3000 rpm | 400 VAC | 50 Hz | 3 PH |
Cooling air fan motor Load compartment.
0436 88VG-1 1605
Characteristics: 7,5 kW | 1450 rpm | 400 VAC | 50 Hz | 3 PH |
Cooling air fan motor Load compartment.
0436 88VG-2 1605
Characteristics: 7,5 kW | 1450 rpm | 400 VAC | 50 Hz | 3 PH |
Cooling air fan motor – Gas compartment
0436 88VL-1 1605
Characteristics: 0.37 kW | - rpm | 400 VAC | 50 Hz | 3 PH |
Cooling air fan motor – Gas compartment
0436 88VL-2 1605
Characteristics: 0.37 kW | - rpm | 400 VAC | 50 Hz | 3 PH |
Water injection system Pump motor
0462 88WN-1 A035
Characteristics: 55 kW | 3000 rpm | 400 VAC | 50 Hz | 3 PH |
0422 90SR-1 0541 Speed ratio/stop valve servo valve
0469 90TV-1 0540 Inlet Guide Vane Servovalve
Electro-pneumatic converter for VC4-1 control valve
0462 90WN-1 A035 Settings : 4,00 ± 0,20 mA for 0,00 ± 0,010 BAR (0 mm)
20,00 ± 0,20 mA = 2,40 ± 0,010 BAR (19 mm)
Ignition exciter
0415 95SG-13 1213
Characteristics : 150 VA | 115 VAC (or 230 VAC) | 15 kV | 150 VA
Ignition exciter
0415 95SG-14 1213
Characteristics : 150 VA | 115 VAC (or 230 VAC) | 15 kV | 150 VA
0415 95SP-13 1214 Spark plug for combustion chamber 13
0415 95SP-14 1214 Spark plug for combustion chamber 14
Atomizing air main compressor differential pressure transmitter
0425 96AD-1 0926 Settings: 4 ± 0.05 mA for 0 bar
20 ± 0.05 mA for 6 bar (87 psi)
Pressure transmitter
0492 96AP-1A 0559 Settings: 4 mA ± 0,02 mA for 0,800 bar (23,6 in of Hg)
20 mA ± 0,10 mA for 1,200 bar (35,4 in of Hg)
Pressure transmitter
0492 96AP-1B 0559 Settings: 4 mA ± 0,02 mA for 0,800 bar (23,6 in of Hg)
20 mA ± 0,10 mA for 1,200 bar (35,4 in of Hg)
Pressure transmitter
0492 96AP-1C 0559 Settings: 4 mA ± 0,02 mA for 0,800 bar (23,6 in of Hg)
20 mA ± 0,10 mA for 1,200 bar (35,4 in of Hg)
Compressor Discharge Pressure Transmitter
0417 96CD-1A 0557 Settings: 4 ± 0.05 for 0 bar ( 0 psi )
20 ± 0.05 for 21 bar ( 304.5 psi )

GENERAL ELECTRIC COMPANY SIZE CAGE CODE DWG NO

g GE Energy Products - Europe


A4
113A7969

DRAWN M. JEZEQUEL SECTION 01E

SCALE SHEET 7
SIZE DWG NO SH REV
A4 113A7969 8 D

Item Item
Devices Designation
PID TG
Compressor Discharge Pressure Transmitter
0417 96CD-1B 0557 Settings: 4 ± 0.05 for 0 bar ( 0 psi )
20 ± 0.05 for 21 bar ( 304.5 psi )
Compressor Discharge Pressure Transmitter
0417 96CD-1C 0557 Settings: 4 ± 0.05 for 0 bar ( 0 psi )
20 ± 0.05 for 21 bar ( 304.5 psi )
Pressure transmitter
0492 96CS-1 0559 Settings: 4 mA ± 0,02 mA for 0,0000 bar
20 mA ± 0,10 mA for 0,0274 bar (11 in of H2O)
GT air inlet system differential pressure transmitter
0471 96CS-3 A040 Settings: 4 ± 0,05 mA for 0 mbar
20 ± 0,05 mA for 24,9 mbar
Exhaust Pressure Transmitter
0422 96FG-1 0557 Settings: 4 ± 0,05 mA for 0 bar ( 0 psi)
20 ± 0,1 mA for 35 bar (510 psi)
Fuel Gas inter-valve Pressure Transmitter
0422 96FG-2A 0557 Settings: 0 ± 0,05V for 0 bar (0 psi)
5 ± 0,05 V for 34,5 bar (500 psi)
Fuel Gas inter-valve Pressure Transmitter
0422 96FG-2B 0557 Settings: 0 ± 0,05V for 0 bar (0 psi)
5 ± 0,05 V for 34,5 bar (500 psi)
Fuel Gas inter-valve Pressure Transmitter
0422 96FG-2C 0557 Settings: 0 ± 0,05V for 0 bar (0 psi)
5 ± 0,05 V for 34,5 bar (500 psi)
Mass flow transmitter
0422 96FM-1 0639 Settings: Factory Calibrated : 4 ± 0,05 mA for 0 kg/s ( 0 lms/s)
20 ± 0,1 mA for 10 kg/s ( 22 lbm/s)
Gas control valve LVDT
0422 96GC-1,2 0509
Settings: 0,7 ± 0,01 VAC for 0 mm
Lube Oil header Pressure transducer
0416 96QA-2 0926 Settings: 4 ± 0,05 mA for 0 bar (0 psi)
20 ± 0,1mA for 7 bar (101,5 psi)
Low Lube Oil Pressure transmitter generator
0416 96QT-2B ALT. Settings : 4 ± 0,05 mA for 0 bar (0 psig)
20 ± 0,1 mA for 1,72 bar (25 psig)
Dew point and temperature transmitter
Settings: Outlet 1 : 4 ± 0,05 mA for –50°C
0471 96RH A040 20 ± 0,05 mA for +50°C
Outlet 2 : 4 ± 0,05 mA for 0% RH
20 ± 0,05 mA for 100 % RH
Stop Ratio Fuel Gas (VSR-1) LVDT
0422 96SR-1,2 0507
Settings: 0.7 ± 0,01 VAC for 0 mm
GT air filter clogging differential pressure transmitter
0471 96TF-1 A040 Settings: 4 ± 0,05 mA for 0 mbar
20 ± 0,05 mA for 25 mbar
Torque Converter IGV Position Transmitter
0421 96TM-1 0605 Settings: 4 ± 0,05 for 0 tr
20 ± 0,05 for 31 tr
Inlet Guide Valve LVDT
0469 96TV-1 0548
Settings: 0,7 ± 0,01 VAC for 34°
Inlet Guide Vane Actuator LVDT (Linear variable displacement transmitter)
0469 96TV-2 0548
Settings: 0,7 ± 0,01 VAC for 34°
Vibration Sensor
0415 96VC-11 0235 Characteristics: Output proximitor : 7,87 V/mm
Settings: Regulation at 1,14 mm (0,045 in)
Vibration Sensor
0415 96VC-12 0235 Characteristics: Output proximitor : 7,87 V/mm
Settings: Regulation at 1,14 mm (0,045 in)
Flow transmitter of the Water injection flow meter FM1-1
0462 96WF-4 A035 Settings : 4 ± 0,05 mA for 0 m3/h
20 ± 0,1 mA for 15 m3/h
Atomizing air precooler air discharge thermocouple.
0425 AAT-1A 0637
Characteristics: Type K
Atomizing air precooler air discharge thermocouple.
0425 AAT-2A 0637
Characteristics: Type K

GENERAL ELECTRIC COMPANY SIZE CAGE CODE DWG NO

g GE Energy Products - Europe


A4
113A7969

DRAWN M. JEZEQUEL SECTION 01E

SCALE SHEET 8
SIZE DWG NO SH REV
A4 113A7969 9 D

Item Item
Devices Designation
PID TG
Control oil hydraulic accumulator
0434 AH1-1 0502 Characteristics: Capacity : 2,5 gal | Nitrogen
Settings: 51,7 ± 1 bar (750 ± 15 psi)
Control oil hydraulic accumulator
0434 AH1-2 0502 Characteristics: Capacity : 2,5 gal | Nitrogen
Settings: 51,7 ± 1 bar (750 ± 15 psi)
Water injection compartment inside temperature measurement
0436 AT-JC-1 1605 Characteristics: type K
Settings: +15°C / +8°C
Load compartment temperature
0436 AT-LC-1 0637
Characteristics: PT100 | 100 ohms at 0°C | 0,385 ohm / °C |
Turbine compartment temperature
0436 AT-TC-1 0637
Characteristics: PT100 | 100 ohms at 0°C | 0,385 ohm / °C |
Thermocouple temperature Bearing bushing n°1
0415 BT-J1-1A,1B 0235
Characteristics: Type K
Thermocouple temperature Bearing bushing n°1
0415 BT-J1-2A,2B 0235
Characteristics: Type K
Thermocouple temperature Bearing bushing n°2
0415 BT-J2-1A,1B 0235
Characteristics: Type K
Thermocouple temperature Bearing bushing n°2
0415 BT-J2-2A,2B 0235
Characteristics: Type K
Thermocouple temperature Bearing bushing n°3
0415 BT-J3-1A,1B 0235
Characteristics: Type K
Thermocouple temperature Bearing bushing n°3
0415 BT-J3-2A,2B 0235
Characteristics: Type K
Thermocouple temperature pad n°2 of thrust bearing n°1
0415 BT-TA1-2A,2B 0235
Characteristics: Type K
Thermocouple temperature pad n°5 of thrust bearing n°1
0415 BT-TA1-5A,5B 0235
Characteristics: Type K
Thermocouple temperature pad n°8 of thrust bearing n°1
0415 BT-TA1-8A,8B 0235
Characteristics: Type K
Thermocouple temperature pad n°2 of counter thrust bearing n°1
0415 BT-TI1-2A,2B 0235
Characteristics: Type K
Thermocouple temperature pad n°5 of counter thrust bearing n°1
0415 BT-TI1-5A,5B 0235
Characteristics: Type K
Thermocouple temperature pad n°9 of counter thrust bearing n°1
0415 BT-TI1-9A,9B 0235
Characteristics: Type K
Main atomizing air compressor.
0425 CA1 0607
Characteristics: Centrifugal | 2,7kg/s | 6500 rpm
Booster Atomizing Air Compressor.
0425 CA2 1047
Characteristics: Volumetric | 510m3/h | 6200 rpm
Thermocouple temperature air outlet of compressor
0415 CT-DA-1 0637
Characteristics: Type K
Thermocouple temperature air outlet of compressor
0415 CT-DA-2 0637
Characteristics: Type K
Thermocouple temperature air inlet of compressor
0415 CT-IF-1 0637
Characteristics: Type K
Thermocouple temperature air inlet of compressor
0415 CT-IF-2 0637
Characteristics: Type K
Cranking Motor Stator Ph1 Temp Sensor 1
0421 ET-CRS-11/R 0603
Characteristics: Pt100-3 wires | 100 ohms at 0 °C | 0,385 ohm / °C | Range –50 to +260 °C
Cranking Motor Stator Ph1Temp Sensor 2
0421 ET-CRS-12/R 0603
Characteristics: Pt100-3 wires | 100 ohms at 0 °C | 0,385 ohm / °C | Range –50 to +260 °C
Cranking Motor Stator Ph2 Temp Sensor 1
0421 ET-CRS-21/R 0603
Characteristics: Pt100-3 wires | 100 ohms at 0 °C | 0,385 ohm / °C | Range –50 to +260 °C
Cranking Motor Stator Ph2 Temp Sensor 2
0421 ET-CRS-22/R 0603
Characteristics: Pt100-3 wires | 100 ohms at 0 °C | 0,385 ohm / °C | Range –50 to +260 °C
Cranking Motor Stator Ph3 Temp Sensor 1
0421 ET-CRS-31/R 0603
Characteristics: Pt100-3 wires | 100 ohms at 0 °C | 0,385 ohm / °C | Range –50 to +260 °C
Cranking Motor Stator Ph3 Temp Sensor 2
0421 ET-CRS-32/R 0603
Characteristics: Pt100-3 wires | 100 ohms at 0 °C | 0,385 ohm / °C | Range –50 to +260 °C
0477 FA3-1 918T Liquid fuel purge air filter.
0425 FA4-1 0983 Atomizing air actuation air filter.
0477 FA6-1 1015 Filter on actuation air of fuel gas purge air valves.
0462 FA8-2 A035 Strainer on control air supply circuit

GENERAL ELECTRIC COMPANY SIZE CAGE CODE DWG NO

g GE Energy Products - Europe


A4
113A7969

DRAWN M. JEZEQUEL SECTION 01E

SCALE SHEET 9
SIZE DWG NO SH REV
A4 113A7969 10 D

Item Item
Devices Designation
PID TG
Flow divider
0424 FD1-1 0613
Characteristics: Volumetric | 883 l/min | 1650 Hz | 1650 tr/min
0424 FF2-1 1014 HP fuel filter
0424 FF2-2 1014 HP fuel filter
0494 FF31-1 E021 Filter before the pumps
0434 FH2-1 1051 Hydraulic supply filter
0434 FH2-2 1051 Hydraulic supply filter
0424 FH3 0992 Hydraulic supply filter-liquid fuel servo
0469 FH6-1 0548 IGV controller assembly hydraulic oil supply filter
0422 FH7-1 0911 Servo hydraulic supply filter of Gas fuel control & stop valve
0422 FH8-1 0991 Gas Fuel Control Valve (VGC-1) Servo Hydraulic Oil Supply Filte
Water injection flow meter
0462 FM1-1 A035
Characteristics: Flow range : 4,4 to 176 GPM
Resistive temperature device connected to 96FM-1
0422 FT-MG-1/R 0639
Characteristics: Type : PT100
0462 FW1-1 A035 High Pressure Water injection main filter
0462 FW1-2 A035 Water injection system low pressure strainer
0421 HM1 0605 Torque Converter and Reversing Gear
Actuator assembly, Inlet Guide Vane System
0469 HM3-1 0548
Settings: Actuator operation limits : 32° to 86°
0425 HX1-1 1003 Atomizing air precooler.
Lube Oil Thermocouple #1 Bearing Drain
0416 LT-B1D-1A,1B 0637
Characteristics: Type K
Lube Oil Thermocouple #2 Bearing Drain
0416 LT-B2D-1A,1B 0637
Characteristics: Type K
Lube Oil Thermocouple #3 Bearing Drain
0416 LT-B3D-1A,1B 0637
Characteristics: Type K
Lube Oil Thermocouple #1 Bearing Drain
0416 LT-BT1D-1A,1B 0637
Characteristics: Type K
ALT./ Lube Oil generator #1 Bearing Drain Resistance Temperature Detector
0416 LT-G1D-1
GEN. Characteristics : PT100 | 100 Ohms à 0°C |
ALT./ Lube Oil generator #2 Bearing Drain Resistance Temperature Detector
0416 LT-G2D-1
GEN. Characteristics : PT100 | 100 Ohms à 0°C |
Lube oil tank resistance temperature detector
0416 LT-OT-1A 0938
Characteristics: Type K
Lube oil tank resistance temperature detector
0416 LT-OT-2A 0938
Characteristics: Type K
Lube oil temperature turbine header thermocouple
0416 LT-TH-1A,1B 0637
Characteristics: Type K
Lube oil temperature turbine header thermocouple
0416 LT-TH-2A,2B 0637
Characteristics: Type K
Lube oil temperature turbine header thermocouple
0416 LT-TH-3A,3B 0637
Characteristics: Type K
0422 MG1 0512 Gas fuel nozzle
0422 MG2-1 0639 Gas fuel metering tube-orifice
Main fuel Pump
0424 PF1 0611
Characteristics: Volumetric | 870.5 l/min | 68.9 bar | 1550 tr/min
Unloading pump
0494 PFA-30 E021
Characteristics: Volumetric type | 25 l/min |
Dosing pump
0494 PFA-31 E021
Characteristics: Volumetric and piston pump | 25 l/h (6.60 Gal/h) | 10 bar (145 psi) | 1500 tr/min
Dosing pump
0494 PFA-32 E021
Characteristics: Volumetric and piston pump | 25 l/h (6.60 Gal/h) | 10 bar (145 psi) | 1500 tr/min
Main hydraulic supply pump
0434 PH1 0627 Characteristics: Volumetric – positive displacement 65 l/min (17,1 GPM) |105 bar (1500 psi) | 1422 tr/min (1422
RPM)
Auxiliary hydraulic supply pump
0434 PH2 0628
Characteristics: Volumetric 45,4 l/min (12 GPM) | 105 Bar (1500 psi) |1450 tr/min (1450 RPM)
Breather valve of 501BA tank
0494 PSV-31 E021 Characteristics: Normal : NC
Settings: Overpressure : 0.15 bar; Vacuum : 0.01 bar
0462 PW1-1 A035 Pump unit
Light warning accessory compartment
0426 SLI-1 1104
Characteristics: 230 UPS – 50 Hz

GENERAL ELECTRIC COMPANY SIZE CAGE CODE DWG NO

g GE Energy Products - Europe


A4
113A7969

DRAWN M. JEZEQUEL SECTION 01E

SCALE SHEET 10
SIZE DWG NO SH REV
A4 113A7969 11 D

Item Item
Devices Designation
PID TG
Fire alarm : flashing light unit
0426 SLI-1A 1605
Characteristics: 24VDC
Fire alarm : flashing light unit
0426 SLI-1B 1605
Characteristics: 24VDC
Fire alarm : horn and flashing light unit load
0426 SLI-1C 1605
Characteristics: 24VDC
Light warning accessory compartment
0426 SLI-2 1104
Characteristics: 230 UPS – 50 Hz
Fire alarm : horn and flashing light unit load
0426 SLI-2C 1605
Characteristics: 24VDC
Fire alarm : horn and flashing light unit load
0426 SLI-3C 1605
Characteristics: 24VDC
Thermocouple temperature exhaust tunnel
0415 TT-IB-1 0637
Characteristics: Type K
Thermocouple temperature external position after first wheel
0415 TT-WS1A0-1 0637
Characteristics: Type K
Thermocouple temperature external position after first wheel
0415 TT-WS1A0-2 0637
Characteristics: Type K
Thermocouple temperature internal position before first wheel
0415 TT-WS1FI-1 0637
Characteristics: Type K
Thermocouple temperature internal position before first wheel
0415 TT-WS1FI-2 0637
Characteristics: Type K
Thermocouple temperature external position after second wheel
0415 TT-WS2AO-1 0637
Characteristics: Type K
Thermocouple temperature external position after second wheel
0415 TT-WS2AO-2 0637
Characteristics: Type K
Thermocouple temperature external position before second wheel
0415 TT-WS2FO-1 0637
Characteristics: Type K
Thermocouple temperature external position before second wheel
0415 TT-WS2FO-2 0637
Characteristics: Type K
Thermocouple temperature external position after third wheel
0415 TT-WS3AO-1 0637
Characteristics: Type K
Thermocouple temperature external position after third wheel
0415 TT-WS3AO-2 0637
Characteristics: Type K
Thermocouple temperature external position before third wheel
0415 TT-WS3FO-1 0637
Characteristics: Type K
Thermocouple temperature external position before third wheel
0415 TT-WS3FO-2 0637
Characteristics: Type K
Thermocouple temperature GT exhaust
0415 TT-XD-1 0623
Characteristics: Type K
Thermocouple temperature GT exhaust
0415 TT-XD-10 0623
Characteristics: Type K
Thermocouple temperature GT exhaust
0415 TT-XD-11 0623
Characteristics: Type K
Thermocouple temperature GT exhaust
0415 TT-XD-12 0623
Characteristics: Type K
Thermocouple temperature GT exhaust
0415 TT-XD-13 0623
Characteristics: Type K
Thermocouple temperature GT exhaust
0415 TT-XD-14 0623
Characteristics: Type K
Thermocouple temperature GT exhaust
0415 TT-XD-15 0623
Characteristics: Type K
Thermocouple temperature GT exhaust
0415 TT-XD-16 0623
Characteristics: Type K
Thermocouple temperature GT exhaust
0415 TT-XD-17 0623
Characteristics: Type K
Thermocouple temperature GT exhaust
0415 TT-XD-18 0623
Characteristics: Type K
Thermocouple temperature GT exhaust
0415 TT-XD-19 0623
Characteristics: Type K
Thermocouple temperature GT exhaust
0415 TT-XD-2 0623
Characteristics: Type K
Thermocouple temperature GT exhaust
0415 TT-XD-20 0623
Characteristics: Type K

GENERAL ELECTRIC COMPANY SIZE CAGE CODE DWG NO

g GE Energy Products - Europe


A4
113A7969

DRAWN M. JEZEQUEL SECTION 01E

SCALE SHEET 11
SIZE DWG NO SH REV
A4 113A7969 12 D

Item Item
Devices Designation
PID TG
Thermocouple temperature GT exhaust
0415 TT-XD-21 0623
Characteristics: Type K
Thermocouple temperature GT exhaust
0415 TT-XD-22 0623
Characteristics: Type K
Thermocouple temperature GT exhaust
0415 TT-XD-23 0623
Characteristics: Type K
Thermocouple temperature GT exhaust
0415 TT-XD-24 0623
Characteristics: Type K
Thermocouple temperature GT exhaust
0415 TT-XD-3 0623
Characteristics: Type K
Thermocouple temperature GT exhaust
0415 TT-XD-4 0623
Characteristics: Type K
Thermocouple temperature GT exhaust
0415 TT-XD-5 0623
Characteristics: Type K
Thermocouple temperature GT exhaust
0415 TT-XD-6 0623
Characteristics: Type K
Thermocouple temperature GT exhaust
0415 TT-XD-7 0623
Characteristics: Type K
Thermocouple temperature GT exhaust
0415 TT-XD-8 0623
Characteristics: Type K
Thermocouple temperature GT exhaust
0415 TT-XD-9 0623
Characteristics: Type K
Gas fuel purge air valve.
0477 VA13-1 0918
Characteristics: Normal: NC
Gas fuel purge air valve.
0477 VA13-2 0918
Characteristics: Normal: NC
False start drain valve-combustion wrapper
0424 VA17-1 1026
Settings: Normal : NO
False start drain valve-exhaust frame
0424 VA17-2 1026
Settings: Normal : NO
False start drain valve-exhaust plenum
0424 VA17-5 1026
Characteristics: Normal : NO
Atomizing air compressor by pass valve.
0425 VA18-1 1070
Characteristics: Normal: NC
Liquide fuel purge air valve.
0477 VA19-1 918T
Characteristics: Normal : C to L opened ; U closed
Compressor Bleed valve 11th stage
0417 VA2-1 1022
Characteristics: Normal : NO
Compressor Bleed valve 11th stage
0417 VA2-2 1022
Characteristics: Normal : NO
Booster atomizing air compressor isolating valve.
0425 VA22-1 0922
Characteristics: Normal: NO
Compressor Bleed valve 11th stage
0417 VA2-3 1022
Characteristics: Normal : NO
Compressor Bleed valve 11th stage
0417 VA2-4 1022
Characteristics: Normal : NO
Pneumatic valve
0494 VA99-31 E021
Characteristics: Normal : NO
Pneumatic valve
0494 VA99-32 E021
Characteristics: Normal : NC
Pneumatic valve
0494 VA99-33 E021
Characteristics: Normal : NO
0434 VAB1 0947 Hydraulic system air bleed valve (main)
0434 VAB2 0947 Hydraulic system air bleed valve (aux.)
By pass control valve
0424 VC3 0516 Characteristics: Normal : NO
Stroke : 1,125 in
0462 VC4-1 A035 Water injection flow control valve
Liquid fuel nozzle check valve
0424 VCK1-1T14 0961 Characteristics: Normal: NC
Cracking press : 8,27 ± 0,34 Bar (120 ± 5 psig)
Liquid fuel nozzle purge air check valve.
0477 VCK2-1T14 918T Characteristics: Normal: NC
Cracking pressure 0.34 ± 0.07 bar (4.93 ± 1 psi).
0434 VCK3-1 0947 Hydraulic pump check valve for main pump

GENERAL ELECTRIC COMPANY SIZE CAGE CODE DWG NO

g GE Energy Products - Europe


A4
113A7969

DRAWN M. JEZEQUEL SECTION 01E

SCALE SHEET 12
SIZE DWG NO SH REV
A4 113A7969 13 D

Item Item
Devices Designation
PID TG
0434 VCK3-2 0947 Hydraulic pump check valve for auxiliary pump
Turbine Shell and Exhaust Frame Blower Check Valve
0417 VCK7-1 1233
Characteristics: Normal : NC
Turbine Shell and Exhaust Frame Blower Check Valve
0417 VCK7-2 1233
Characteristics: Normal : NC
Gas control valve
0422 VGC-1 0509 Characteristics: Normal : NC
stroke maxi : 44,5 ± 0,5 mm
0469 VH3-1 0540 Trip relay, hydraulic, IGV
VSR security discharge valve
0422 VH5-1 0507
Characteristics: Normal : NO
VGC trip valve
0422 VH5-2 0509
Characteristics: Normal : NO
0434 VM4 1052 Hydraulic filter transfer valve
0424 VP-1 0961 Fuel liquid purge multiport valve
0424 VP-2 0961 Fuel liquid purge multiport valve
Bearing header pressure regulator valve
0416 VPR2-1 1023 Characteristics: Normal : NC
Settings: Set point : 1,72 + 0,13 /-0 bar (25 + 2 /-0 psi)
Filter regulator
0494 VPR30-31 E021 Characteristics: Normal : NO
Settings: 4 bar (58 psi)
Hydraulic supply pump (PH1) compensator
0434 VPR3-1 0627
Settings: Setting : 1500 +20/-0 psig
Filter pressure regulator on actuation air of gas fuel purge air valve.
0477 VPR44-1 0918
Settings: 2,3 +0/-0,2 bar (33,35 +0/-2,9 psi)
Filter pressure regulator on actuation air of gas fuel purge air valve.
0477 VPR44-2 0918
Settings: 2,3 +0/-0,2 bar (33,35 +0/-2,9 psi)
Filter pressure regulator on actuation air of liquid fuel purge air valve.
0477 VPR54-1 0918
Settings: 3,27 +1,7/-0 bar (47,5 +2,7/-0 psi)
Water injection VC4-1 transfer valve air pressure regulation
0462 VPR62-1 A035 Characteristics: Normal: NC
Settings: Setting: 35.00 ± 5.00 PSI
Water injection stop valve pressure regulator
0462 VPR62-11 A035 Characteristics: Normal : NC
Settings: 6,9 ± 0.340 bar (100 ± 4,9 psi)
Instrumentation air filter pressure regulator on VA22-1 actuation.
0425 VPR68-1 0922
Settings: 3,79 ± 0,13 bar (55 ± 2 psi)
Quick exhaust valve
0462 VQE1-1 A035
Characteristics: Normal : NC
Main lube oil pump pressure relief valve
0416 VR1 1016 Characteristics: Normal : NC
Settings: Opening at 6,89 + 0,13/-0 bar (100 + 2/-0 psi)
Main hydraulic supply pump pressure relief valve
0434 VR21 0947
Settings: 1650 ± 20 psi
Auxiliary hydraulic supply pump pressure relief valve
0434 VR22 0947
Settings: Setting : 1650 ± 20 psig
Pressure relief valve on liq. Fuel piping
0424 VR27 0992 Characteristics: Normal: NC
Settings: Setting : 6 ± 0,2 bar (87 ± 2,9 psi)
Main fuel pump pressure relief valve
0424 VR4 0992 Characteristics: Normal : NC
Settings: Setting : 82,7 ± 1,72 bar (1200 ± 25 psi)
PFA-31 Pump relief pressure valve
0494 VR60-31 E021 Characteristics: Normal : NC
Settings: Opening at 12 ± 1 bar (174 ± 14,5 psi)
PFA-32 Pump relief pressure valve
0494 VR60-32 E021 Characteristics: Normal : NC
Settings: Opening at 12 ± 1 bar (174 ± 14,5 psi)
Fuel oil stop valve
0424 VS1 0511
Characteristics: Normal : NC
Water injection stop valve
0462 VS2-1 A035
Characteristics: Normal : NC
Fuel gas stop/speed ratio valve
0422 VSR-1 0507
Characteristics: Normal : NC | stroke maxi : 88,67 mm ( 3,5 in)

GENERAL ELECTRIC COMPANY SIZE CAGE CODE DWG NO

g GE Energy Products - Europe


A4
113A7969

DRAWN M. JEZEQUEL SECTION 01E

SCALE SHEET 13
SIZE DWG NO SH REV
A4 113A7969 14 D

Item Item
Devices Designation
PID TG
Bearing header temperature regulator valve
0420 VTR1 1035 Characteristics: Normal: E to B open, C closed.
Settings: Starts to open at Oil T° = 130 ± 3.6 F.
Atomising air precooler air discharge temperature regulator valve
0420 VTR2-1 1027 Characteristics: Normal: B to E open, C closed.
Settings: T° air = 225 ± 3.6 F
Resistance thermometer detector Support legs water temperature
0420 WT-TL-1 0637
Characteristics: Platinum PT100 | 100 Ohm at 32°F | 0,214 Ohm / °F | -58 to 500 °F
Resistance thermometer detector Support legs water temperature
0420 WT-TL-2 0637
Characteristics: Platinum PT100 | 100 Ohm at 32°F | 0,214 Ohm / °F | -58 to 500 °F

GENERAL ELECTRIC COMPANY SIZE CAGE CODE DWG NO

g GE Energy Products - Europe


A4
113A7969

DRAWN M. JEZEQUEL SECTION 01E

SCALE SHEET 14

You might also like