Model 4150
Model 4150
The 4000 Series is a line of fully adjustable protection, arc protection, and reverse polarity
DC to DC converters providing an economical protection are standard as well as remote on/
source of high voltage that is ideal for CRT’s, off and a 0 to 10 volt output voltage monitor.
lasers, Q switches, PMT’s, detectors, electron The 4000 Series has a built-in 10V precision
and ion guns, capacitor charging, test reference output available. These units also
equipment, and many other applications. feature excellent EMI/RFI shielding. Two #6-
These units feature remote voltage 32 studs mount the supply in a three inch
programming, resistance programming, or mounting pattern. Call, e-mail or fax your
manual adjustability via an externally requirements for immediate attention.
accessible potentiometer. Short circuit
FEATURES
0 to 100% Adjustability OUTPUT OUTPUT *1 RIPPLE INPUT CURRENT
Voltage Programmable: MODEL VOLTAGE CURRENT P-P NO LOAD FULL LOAD
high impedance input,>100K ohm
4010 0 to 1,000 10 mA .1% <100 mA <1.0 A
Voltage Monitor *2
Remote On/Off Control 4020 0 to 2,000 5 mA .1% <100 mA <1.0 A
EMI/RFI Shielding
Short Circuit Protection 4030 0 to 3,000 3.3 mA .2% <130 mA <1.0 A
Reverse Polarity Protection 4050 0 to 5,000 2 mA .1% <150 mA <1.0 A
Arc Protection
4070 0 to 7,000 1.4 mA .1% <160 mA <1.0 A
APPLICATIONS
Cathode Ray Tubes 4100 0 to 10,000 1 mA .1% <175 mA <1.0 A
Lasers and Q Switches
4120 0 to 12,000 .8 mA .1% <190 mA <1.0 A
Capacitor Charging
Test Instrumentation 4150 0 to 15,000 .67 mA .1% <190 mA <1.0 A
Electrostatic Field Generators
4200 0 to 20,000 .5 mA .2% <230 mA <1.0 A
Electrophoresis
2
4300* 0 to 30,000 .33 mA .4% <270 mA <1.0 A
OPTIONS
Negative Output Voltage, 4330* 2
0 to 33,000 .30mA .2% <400 mA <1.0 A
put “N” after model(Forexample:4300N)
RoHS(- ‘R’ suffix denotes the product is designed to meet RoHS
requirements i.e 4010R)
Epoxy: A. Low Outgassing (NASA approved per ASTM E-595-93) *Note: 1. At Maximum Rated Output Voltage.
B. UL 94 V0 flammability rating 2. No Voltage Monitor
Output Connector (AMP#861753-1): Available for models 4010 thru 4150
PHYSICAL CHARACTERISTICS
MODELS 4010 thru 4200 • SIZE: 4.1 (104) x 3.1 (78.7) x 1.4 (35.56)
MODELS 4300 thru 4330 • SIZE: 4.1 (104) x 3.6 (91.4) x 1.4 (35.56) Programming Voltage vs Output Voltage
WEIGHT: 1.5 Pound (.675 kg.) Approx.
CASE MATERIAL: Black Anodized Aluminum
INPUT CONNECTOR: Molex Header 09-75-2074 100
MATING CONNECTOR: Molex Crimp Terminal Housing 09-50-3071 (Supplied)
MOLEX Crimp Terminals: 08-50-0106 (supplied) 80
Output Voltage
4705AD
0 to + or - 1,000 through 0 to + or - 33,000 VDC @ 10 Watts
4000 Series
0.33 (8.38)
0.53(13.5)
1.28 1.17
(32.5) (29.7)
1.55(39.2)
0.41(10.33)
3.00 4.10
(76.20) (104.14)
PROGRAMMING
PIN FUNCTION VOLTAGE: Apply 0-10V to pin 5 for 0-
100% output.
1 On-Off Control
Ground/Case
0.56 (14.29)
2 RESISTANCE: Connect potentiometer to pin 4
3 +24 Volt Input 1.55 (reference voltage), connect
(39.37) wiper arm to pin 5, and connect
4 10 Volt Reference Output 6-32/M3.5 potentiometer to ground.
3.1(78.7) MOUNTING STUD
5 Programming Voltage 2 PLACES
6 Internal Potentiometer
MANUAL: Connect pin 6 to pin 5, turn
7 Voltage Monitor front panel pot for voltage
adjust.
3.7(93.9) HIGH VOLTAGE
(INCLUDING HARDWARE) OUTPUT LEAD
(35.56)
0.84(21.3) 0.80(20.3)
0.33 (8.38)
0.53(13.5)
1.78 1.17
(32.5) (29.7)
1.55(39.2)
0.41(10.33)
3.00 4.10
(76.20) (104.14)
0.56 (14.29)
1.80
(39.37) 6-32/M3.5
3.6(91.4) MOUNTING STUD
2 PLACES