200 MK3 Data
200 MK3 Data
USB
USB
ho
TECHNICAL SPECIFICATIONS
Alternator voltage: 0 to 300 V-AC (Ph-N) Maximum humidity: 95% non-condensing.
Alternator frequency: 0-600 Hz. IP Protection: IP65 from front panel, IP30 from the rear
Mains voltage: 0 to 300 V-AC (Ph-N) (with gasket)
Mains frequency: 0-600 Hz. Dimensions: 133 x 107 x 46mm (WxHxD)
Topology: 1-2-3 phases, with or without neutral Panel Cut-out Dimensions: 117 x 87 mm minimum.
DC Supply Range: 8.0 to 36.0 V-DC. Weight: 250 g (approx.)
V-A-cos Accuracy: 0.5% + 1 digit Case Material: High Temperature, non-flammable
kW-kVA-kVAr Accuracy: 1.0% + 1 digit ABS/PC
Current consumption: 180 mA-DC max @ 12V-DC Installation: Flat surface mounting on a Type 1 enclosure.
Current Inputs: current transformers. ../5A or ../1A. Rear retaining plastic brackets.
Digital inputs: input voltage 0 to 36 V-DC.
Analog input range: 0-5000 ohms.
Mains and genset contactor outputs: 16Amps@250V CONFORMITY
DC Outputs: Protected mosfet semiconductor outputs,
rated 1Amp@28V-DC EU Directives Conformity
Cranking dropouts: survives 0V for 100ms. -2014/35/EC (low voltage)
Magnetic pickup voltage: 0.5 to 50VAC. -2014/30/EC (electro-magnetic compatibility)
Magnetic pickup frequency: 0 to 10000 Hz. Norms of reference:
Charge Alternator Excitation: 2W. EN 61010 (safety requirements)
Display Screen: 2.9”, 128x64 pixels EN 61326 (EMC requirements)
USB Device: USB 2.0 Full speed UL & CSA Compatibility:
Operating temperature: -20°C to 70°C (-4 to +158 °F) -UL 6200, Controls for Stationary Engine Driven
With optional display heater: -40°C to 70°C (-40 to Assemblies (Certificate # - 20140725-E314374)
+158 °F) -CAN/CSA C22.2 No. 14-13 – Industrial Control
Storage temperature: -40°C to 80°C (-40 to +176°F) Equipment
TYPICAL CONNECTIONS