0% found this document useful (0 votes)
261 views

PLS 4 Manual

1. The document provides operating instructions and safety information for the PLS4 laser level. 2. It describes the various menu functions including leveling beams, plumb beams, self-leveling mode, and points mode. 3. The document also provides instructions for performing accuracy checks on the leveling and plumb lines and warns that the laser should be checked periodically to ensure accuracy.

Uploaded by

Mic B
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
261 views

PLS 4 Manual

1. The document provides operating instructions and safety information for the PLS4 laser level. 2. It describes the various menu functions including leveling beams, plumb beams, self-leveling mode, and points mode. 3. The document also provides instructions for performing accuracy checks on the leveling and plumb lines and warns that the laser should be checked periodically to ensure accuracy.

Uploaded by

Mic B
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

features menu switch safety label

CAUTION: USE OF CONTROLS, ADJUSTMENTS OR PRO-


Operating • ON/OFF MENU
SWITCH
Lines
Press “on/off” to
CEDURES OTHER THAN THOSE SPECIFIED HEREIN MAY

Manual scroll through the


RESULT IN HAZARDOUS RADIATION EXPOSURE.

menu. The numbers


indicate menu

PLS 4
functions:
1. Level/horizontal
beam / green LED
• OPTIC WINDOWS 2. Plumb / vertical
beam / green LED
• 1/4 X 20 INSERT 3. Both beams
IN BASE OF EACH UNIT - self-leveling/
green LED
• BATTERY DOOR 4. Both beams -
fixed / red LED
• MAGNETIC 5. Off Avoid Exposure
PLS4 complies with US FDA Laser radiation
WALL BRACKET • Unless the PLS4 is on number 4 mode, unit will not standards, 21 CFR, Subchapter J. emitted from
operate if tilt exceeds 6o out of level. this aperture
• POUCH These labels are attached to
• Amber led = low battery every PLS laser. These are
• Press “Pulse Line” button to activate pulsed line beams not to be removed or defaced.
• PLS SLD Laser to use outdoors with PLS SLD Laser detector.
detector • Flashing LED indicates laser is pulsing and can be
PLS4 complies with fda performance stds.
21 cfr, subchapter j
used with PLS SLD laser detector.
SERIAL NUMBER:
• Pulsed beam will be less bright than non-pulsed beam. MFGD:

Points Caution: laser radiation when open. Do not


stare into beam or view directly with optical
• Press “on/off” for up-down points / green LED instruments. Patent pending
• Beams will not operate if tilt exceeds 6o / red LED
PACIFIC LASER • Points will not pulse
reg. us patent office
PLS 2550 KERNER BLVD., CA 94901
SYSTEMS PLS4 is a registered trademark of Points and lines can be used simultaneously PLS • 2550 Kerner Blvd., San Rafael, CA 94901
PLS • PACIFIC LASER SYSTEMS
The Professional Standard 800 601 4500
North American
check level lines check plumb warranty specifications
We recommend that you check your PLS4 periodically Lines This product is warranted by PLS · Pacific Laser Systems Light source: Semiconductor laser diode
in order to assure its accuracy. Choose a door jamb with 8’-0” to the original purchaser to be free from defects in mate- 635-670 nm, visible
clear on each side of the door. rial and workmanship under normal use for a period of Working range: +/- 100 feet (outdoor w/detector)
TO CHECK LEVEL: Turn on your PLS4 laser to set- three years from the date of purchase. During the war-
Cross line accuracy: +/- 1/8” @ 30 feet
Choose two interior walls approximately 15’-0” apart (see (+/- 3mm @ 10 meters)
ting #2 (plumb). With your laser ranty period, and upon proof of purchase, the product will
Fig. 1). You can use 2 x 4s for targets. Point-to-point accuracy: +/- 1/4” @ 100 feet
at point A, make two marks on be repaired or replaced (with the same or similar model (+/- 6mm @ 30 meters)
the floor: the first at 8’-0” from at our option), without charge for either parts or labor, Leveling: Automatic
Turn on the PLS4 to setting #1 (level). With the PLS4 six point A centered on door Leveling range: +/- 6o
If level & plumb are within through PLS. The purchaser shall bear all shipping, pack-
inches away from and facing target #1, carefully mark the header above (mark this Power supply: 3AA batteries alkaline or rechargeable
center of the line. Label this mark A1. Swivel the laser specification, square ing and insurance costs. Upon completion of the repair Operating time: +25 hours continuous use with
point B), the second 16’-0” will be in specification.
180º and mark the center of the line on target #2. Label or replacement, the unit will be returned to the customer, single beam; 12.5 hours both beams
from point A (mark this
this mark B1. freight prepaid. The warranty will not apply to this product Operating temp: 0o F to 122o F
point C). Without moving the laser, make
if it has been misused, abused or altered. Without limiting (-18o C to 50o C)
a third mark on the door header (mark this point D). Storage temp: -40o F to 158o F
Move the PLS4 six inches away from and the foregoing, battery leakage, dents or gouges to the
Move the laser to point C, exactly (-40o C to 70o C)
facing target #2. Carefully mark the center of the line. plastic housing, broken optic windows, damage to the Indicator: Green light: ON
Label this mark B2. Swivel the laser 180º and mark the align the beam with point B, and no- switch/LED membrane are presumed to result from mis- Red light: EXCEEDS TILT/ tilt override #4
center of the line on target #1. Label this mark A2. tice where the beam falls at point D. use or abuse. Tampering with or removal of the caution or Amber light: Battery Low
If it is within a “light” 1/16” of point certification labels voids this warranty. Flashing: pulse beam-lines
You now have two centers of elevation at each D, the laser is in calibration. Environment: Water resistant; not submersible
target. Carefully measure the distance between centers Points Dimensions: 2” x 2.5” x 4-3/8”
Neither this warranty nor any other warranty, express or Weight: 16 oz.(.45kg) (including batteries)
of each set of marks. If there is a difference, subtract one Check of Plumb Accuracy. This implied, including implied warranties of merchantability,
measurement from the other. This calibration method mag- requires significant vertical height shall extend beyond the warranty period. No responsibil-
nifies any error by a factor of two. Therefore divide any (minimum 10’-0”) and the ability ity PULSE PLS4 W/DETECTOR
difference by two to find the true error. Your PLS4 should to mark at that height. Place the is assumed for any incidental or Average distance
have an error of no greater than 1/8 in. within 30ft. unit with the down beam exactly and horizontal-
consequential damages. This vertical line
centered on both axes over a cross warranty gives you specific legal length using PLS
mark. At the surface above, mark rights, and you may have other SLD Laser Detector
both axes of up beam. Rotate the laser 180˚ and rights which vary
place the down beam exactly centered on the original from state to state. Fan Angle 180o +
mark. The up beam should be exactly over the
original mark. Distance Line Length Accuracy
If there is a difference between marks the error of the 30ft 75ft + 1/8”
plumb beam is one half that difference. PLS Lab Technicians 100ft 125ft + 3/8”