0% found this document useful (0 votes)
78 views

D - IM - 539 02 Chain Block

This inspection certificate summarizes the inspection of a manually operated chain block located at Peninsula Tower in Dubai. The chain block was given an initial inspection and was found to be in satisfactory working condition and safe to use. The inspection found the equipment to be in compliance with applicable standards and manufacturer recommendations. The certificate is valid for six months unless repairs are made, in which case it must be reinspected according to local requirements.

Uploaded by

NISAR
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
78 views

D - IM - 539 02 Chain Block

This inspection certificate summarizes the inspection of a manually operated chain block located at Peninsula Tower in Dubai. The chain block was given an initial inspection and was found to be in satisfactory working condition and safe to use. The inspection found the equipment to be in compliance with applicable standards and manufacturer recommendations. The certificate is valid for six months unless repairs are made, in which case it must be reinspected according to local requirements.

Uploaded by

NISAR
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 2

IB-198

INSPECTION CERTIFICATE OF CHAIN BLOCK


Company Name: OCR No. 2916
CHINA STATE CONSTRUCTION Certificate No. D – IM – 539/ 02
ENGINEERING COMPANY Job No. D – IM – 539
Date of Inspection 09 / 09 / 2022
Location of Inspection: Expiry Date 08 / 03 / 2023*
PENINSULA TOWER, BUSINESS BAY-DUBAI Date of Last Inspection DNA
Date of Issuance 11 / 09 / 2022
Type of inspection Description of the equipment
INITIAL INSPECTION
PERIODIC INSPECTION ✓ MANUALLY OPERATED CHAIN BLOCK
MAJOR INSPECTION
Proof load Or
Serial No. Safe working
Qty Tested load Remarks
Or ID No. Description (size, type, grade, safety factor, ETC) load, SWL

CHAIN BLOCK

Make : METALLIFT
Model : LGCB316
EWL :6m
01000048 Chain grade :T 01 1 TON 1 TON Satisfactory
Chain diameter : 6 mm
No. of falls :1

Inspection procedure: DASCO – IP – 20


Inspection Tools DASCO – IT – 05, 44
Reference Standard/s BS EN 13157: 2004+A1: 2008
Dubai local order 61/ 1991
EIAC requirements (EIAC-RQ-IB-001) ((EIAC-RQ-IB-002)
EQUIPMENT STATUS:

SAFE TO USE
We hereby certify that the equipment described in this certificate was tested & thoroughly examined by a competent person in accordance with applicable BS Standards &
Manufacturer recommendation. At the time of inspection, the Equipment has been found to be free from any adverse qualities that can affect its safe use and it is safe for
its intended use. DASCO or its inspector will not be liable to any changes in any circumstances.
Notes:
 The validity of the certificate is 6 (six) months, in the event of any repair or alteration made, in which case it must be
Re-inspected as per local requirements.
 The inspection certificate shall not be reproduced except in full without the approval of inspection body (DASCO) and the client.
 After every inspection, a record should be maintained by the operator and kept by the user/owner.
Inspector Name & Signature: Authentication Stamp Authorization name & Signature

Engr. NISARUDEEN Engr. IVAN

Professional License No. 903344 / Tel No. 04 886 7900 / Email: [email protected] / 1st Floor, Office 05 Al Jaber Novelty Building, Nadd Al Hamar, Dubai, UAE / PO Box 473522

DASCO-CRT-18, REV: 02 22-02-2022


CERTIFICATE OF INSPECTION
Certificate No. D – IM – 539/ 2 Job No. D – IM – 539 Date of inspection 09 / 09 / 2022

ITEM DESCRIPTION S F CF NA

1 Declaration of conformity (or) Previous inspection certificate ✓


2 Maintenance log sheet ✓
3 Mfg. Manual & technical instruction ✓
4 Cover guard condition ✓
5 Hand chain / lever ✓
6 Load wheel ✓
7 Hand chain condition ✓
8 Load chain ✓
9 Chain guide ✓

10 Guide roller ✓

11 Chain Stripper ✓

12 Gears and guards ✓

13 Body casing ✓

14 Ratchet Assembly ✓

15 Clutches and breaks ✓

16 Sufficient length ✓

17 Erosion or corrosion ✓

18 Hook condition ✓

S – Satisfactory, F- Finding, CF- Critical Finding, N/A- Not Applicable (use only ✓)

Findings/Critical findings Required Rectification Target closing date

Remarks/Recommendations (If any)


SATISFACTORY AT THE TIME OF INSPECTION

Name & Signature of the inspector: Company seal:

Engr. NISARUDEEN

Professional License No. 903344 / Tel No. 04 886 7900 / Email: [email protected] / 1st Floor, Office 05 Al Jaber Novelty Building, Nadd Al Hamar, Dubai, UAE / PO Box 473522

DASCO-CRT-18, REV: 02 22-02-2022